header advert
Results 1 - 100 of 129
Results per page:
Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_8 | Pages 36 - 36
10 May 2024
Bolam SM Matheson N Douglas M Anderson K Weggerty S Londahl M Gwynne-Jones D Navarre P
Full Access

Introduction

The Te Whatu Ora Southern catchment area covers the largest geographical region in New Zealand (over 62,000 km2) creating logistical challenges in providing timely access to emergency neck of femur (NOF) fracture surgery. Current Australian and New Zealand guidelines recommend that NoF surgery be performed within 48 hours of presentation. The purpose of this study was to compare the outcomes for patients with NoF fractures who present directly to a referral hospital (Southland Hospital) compared to those are transferred from rural peripheral centres.

Methods

A retrospective cohort study identified 79 patients with NoF who were transferred from rural peripheral centres to a referral hospital for operative management between January 2011 to December 2020. This cohort was matched 1:1 by age and sex to patients with NoF who presently directly to the referral hospital over the same period. The primary outcome was to compare time to surgery between the groups and secondary outcomes were to compare length of hospital stay, complication rates and mortality rates at 30-days and 1-year.


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_7 | Pages 15 - 15
8 May 2024
Coetzee C Myerson M Anderson J McGaver RS
Full Access

Introduction

AlloStem/Cellular Bone Allograft and autologous bone graft are accepted methods for managing hindfoot degenerative arthritis. The purpose was to evaluate outcomes of AlloStem and autograft in subtalar arthrodesis and compare overall fusion rates.

Methods

This study was conducted in IRB compliance. Patients between 18–80 years who qualified for a subtalar fusion were randomized 1:1 to AlloStem or autologous graft. The AOFAS hindfoot ankle scale, FFI-R and SF-12 were collected pre-operatively, 6 weeks, 3 & 6 months, 1 and 2 year. Weight-bearing 3-view ankle X-rays were done at the same intervals. A CT scan was obtained at 6 months.


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_6 | Pages 15 - 15
2 May 2024
Williams S Smeeton M Isaac G Anderson J Wilcox R Board T Williams S
Full Access

Dual Mobility (DM) Total Hip Replacements (THRs), are becoming widely used but function in-vivo is not fully understood.

The aim of this study was to compare the incidence of impingement of a modular dual mobility with that of a standard cup.

A geometrical model of one subject's bony anatomy \[1\] was developed, a THR was implanted with the cup at a range of inclination and anteversion positions (Corail® stem, Pinnacle® cup (DePuy Synthes)). Two DM variants and one STD acetabular cup were modelled. Joint motions were taken from kinematic data of activities of daily living associated with dislocation \[2\] and walking. The occurrence of impingement was assessed for each component combination, orientation and activity. Implant-implant impingement can occur between the femoral neck and the metal or PE liner (DM or STD constructs respectively) or neck-PE mobile liner (DM only).

The results comprise a colour coded matrix which sums the number of impingement events for each cup position and activity and for each implant variant.

Neck-PE mobile liner impingement, occurred for both DM sizes, for all activities, and most cup placement positions indicating that the PE mobile liner is likely to move at the start of all activities including walking.

For all constructs no placement positions avoided neck-metal (DM) or neck-PE liner (STD) impingementevents in all activities. The least number of events occurred at higher inclination and anteversion component positions. In addition to implant-implant impingement, some instances of bone-bone and implant-bone impingement were also observed.

Consistent with DM philosophy, neck-PE mobile liner impingement and liner motion occurred for all activities including walking. Neck-liner impingement frequency was comparable between both DM sizes (metal liner) and a standard cup (PE liner).


To examine whether Natural Language Processing (NLP) using a state-of-the-art clinically based Large Language Model (LLM) could predict patient selection for Total Hip Arthroplasty (THA), across a range of routinely available clinical text sources.

Data pre-processing and analyses were conducted according to the Ai to Revolutionise the patient Care pathway in Hip and Knee arthroplasty (ARCHERY) project protocol (https://www.researchprotocols.org/2022/5/e37092/). Three types of deidentified Scottish regional clinical free text data were assessed: Referral letters, radiology reports and clinic letters. NLP algorithms were based on the GatorTron model, a Bidirectional Encoder Representations from Transformers (BERT) based LLM trained on 82 billion words of de-identified clinical text. Three specific inference tasks were performed: assessment of the base GatorTron model, assessment after model-fine tuning, and external validation.

There were 3911, 1621 and 1503 patient text documents included from the sources of referral letters, radiology reports and clinic letters respectively. All letter sources displayed significant class imbalance, with only 15.8%, 24.9%, and 5.9% of patients linked to the respective text source documentation having undergone surgery. Untrained model performance was poor, with F1 scores (harmonic mean of precision and recall) of 0.02, 0.38 and 0.09 respectively. This did however improve with model training, with mean scores (range) of 0.39 (0.31–0.47), 0.57 (0.48–0.63) and 0.32 (0.28–0.39) across the 5 folds of cross-validation. Performance deteriorated on external validation across all three groups but remained highest for the radiology report cohort.

Even with further training on a large cohort of routinely collected free-text data a clinical LLM fails to adequately perform clinical inference in NLP tasks regarding identification of those selected to undergo THA. This likely relates to the complexity and heterogeneity of free-text information and the way that patients are determined to be surgical candidates.


The Bone & Joint Journal
Vol. 106-B, Issue 5 | Pages 501 - 507
1 May 2024
Galloway AM Keene DJ Anderson A Holton C Redmond AC Siddle HJ Richards S Perry DC

Aims

The aim of this study was to produce clinical consensus recommendations about the non-surgical treatment of children with Perthes’ disease. The recommendations are intended to support clinical practice in a condition for which there is no robust evidence to guide optimal care.

Methods

A two-round, modified Delphi study was conducted online. An advisory group of children’s orthopaedic specialists consisting of physiotherapists, surgeons, and clinical nurse specialists designed a survey. In the first round, participants also had the opportunity to suggest new statements. The survey included statements related to ‘Exercises’, ‘Physical activity’, ‘Education/information sharing’, ‘Input from other services’, and ‘Monitoring assessments’. The survey was shared with clinicians who regularly treat children with Perthes’ disease in the UK using clinically relevant specialist groups and social media. A predetermined threshold of ≥ 75% for consensus was used for recommendation, with a threshold of between 70% and 75% being considered as ‘points to consider’.


Bone & Joint Open
Vol. 5, Issue 4 | Pages 277 - 285
8 Apr 2024
Khetan V Baxter I Hampton M Spencer A Anderson A

Aims

The mean age of patients undergoing total knee arthroplasty (TKA) has reduced with time. Younger patients have increased expectations following TKA. Aseptic loosening of the tibial component is the most common cause of failure of TKA in the UK. Interest in cementless TKA has re-emerged due to its encouraging results in the younger patient population. We review a large series of tantalum trabecular metal cementless implants in patients who are at the highest risk of revision surgery.

Methods

A total of 454 consecutive patients who underwent cementless TKA between August 2004 and December 2021 were reviewed. The mean follow-up was ten years. Plain radiographs were analyzed for radiolucent lines. Patients who underwent revision TKA were recorded, and the cause for revision was determined. Data from the National Joint Registry for England, Wales, Northern Island, the Isle of Man and the States of Guernsey (NJR) were compared with our series.


Bone & Joint Research
Vol. 12, Issue 10 | Pages 657 - 666
17 Oct 2023
Sung J Barratt KR Pederson SM Chenu C Reichert I Atkins GJ Anderson PH Smitham PJ

Aims

Impaired fracture repair in patients with type 2 diabetes mellitus (T2DM) is not fully understood. In this study, we aimed to characterize the local changes in gene expression (GE) associated with diabetic fracture. We used an unbiased approach to compare GE in the fracture callus of Zucker diabetic fatty (ZDF) rats relative to wild-type (WT) littermates at three weeks following femoral osteotomy.

Methods

Zucker rats, WT and homozygous for leptin receptor mutation (ZDF), were fed a moderately high-fat diet to induce T2DM only in the ZDF animals. At ten weeks of age, open femoral fractures were simulated using a unilateral osteotomy stabilized with an external fixator. At three weeks post-surgery, the fractured femur from each animal was retrieved for analysis. Callus formation and the extent of healing were assessed by radiograph and histology. Bone tissue was processed for total RNA extraction and messenger RNA (mRNA) sequencing (mRNA-Seq).


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_13 | Pages 32 - 32
7 Aug 2023
Nicholls K Petsiou D Wilcocks K Shean K Anderson J Vachtsevanos L
Full Access

Abstract

Introduction

Surgery in patients with high body mass index (BMI) is more technically challenging and associated with increased complications post-operatively. Inferior clinical and functional mid-term results for high BMI patients undergoing high tibial osteotomy (HTO) relative to normal weight patients have been reported. This study discusses the clinical, radiological and functional outcomes of HTO surgery in patients with a high BMI.

Method

This is a retrospective study on patients undergoing HTO surgery using the Tomofix anatomical MHT plate between 2017 and 2022, with follow-up period of up to 5 years. The cohort was divided: non-obese (BMI <30 kg/m2) and obese (BMI>30 kg/m2). Pre and post operative functional scores were collected: Oxford Knee Score (OKS), EuroQol-5D and Tegner. Complications, plate survivorship and Mikulicz point recorded.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_13 | Pages 56 - 56
7 Aug 2023
Nicholls K Wilcocks K Shean K Anderson J Matthews A Vachtsevanos L
Full Access

Abstract

Introduction

Compared to the standard Tomofix plate, the anatomical Tomofix medial high tibial (MHT) plate has been shown to improve anatomical fit and post correction tibial contour, following high tibial osteotomy (HTO). Clinical data on surgical complications, osteotomy union rates and survivorship with the anatomical Tomofix MHT plate however remain limited. This study reports mid-term results of HTO surgery, using the anatomical Tomofix MHT plate.

Methods

All patients undergoing HTO surgery using the anatomical Tomofix MHT plate between 2017 and 2022 were included in the study. Data on complications, osteotomy union rates and survivorship were collected prospectively and retrospectively analysed.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_12 | Pages 68 - 68
23 Jun 2023
Anderson LA Wylie JD Erickson JA Blackburn BE Peters CL
Full Access

Periacetabular osteotomy (PAO) is the preferred treatment for symptomatic acetabular dysplasia in adolescents and young adults. There remains a lack of consensus regarding whether intra-articular work such as labral repair or improvement of femoral offset should be performed at the time of PAO or addressed subsequent to PAO if symptoms warrant. The purpose was to determine the rate of subsequent hip arthroscopy (HA) in a contemporary PAO cohort with no intra-articular work performed at the time of PAO.

From June 2012 to March 2022, 368 rectus sparing PAOs were performed and followed for a minimum of one year (mean 5.9 years). The average age was 24 (range 14–46) and 89% were female. Patients were evaluated at last follow-up for patient-reported outcomes (PROMs). Clinical records were reviewed for complications or subsequent surgery. Radiographs were reviewed for the following acetabular parameters: LCEA, ACEA, AI, and the alpha-angle (AA). Patients were cross-referenced from the two largest hospital systems in our area to determine if subsequent HA was performed. Descriptive statistics were used to analyze risk factors for HA.

16 hips (15 patients) (4.4%) underwent subsequent HA with labral repair and femoral osteochondroplasty most common. For those with a minimum of two years of follow-up, 5.3% underwent subsequent HA. No hips underwent THA; one revision PAO was performed. 14 hips experienced a complication and 99 underwent hardware removal. All PROMs improved significantly post-operatively. Radiographically 80% of hips were in goal for acetabular correction parameters with no significant differences between those who underwent subsequent HA and those who did not.

Rectus sparing PAO is associated with a low rate of subsequent HA for intra-articular pathology at 5-year follow-up. Acetabular correction alone may be sufficient as the primary intervention for the majority of patients with symptomatic acetabular dysplasia.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_12 | Pages 54 - 54
23 Jun 2023
Shaath MK Yawman J Anderson T Avilucea F Langford J Munro M Haidukewych GJ
Full Access

Intertrochanteric fractures are common, accounting for nearly 30% of all fracture related admissions. Some have suggested that these fractures should be treated in community hospitals so as not to tax the resources of Level One trauma centers. Since many factors predictive of fixation failure are related to technical aspects of the surgery, the purpose of this study was to compare radiographic parameters after fixation comparing trauma fellowship trained surgeons to non-fellowship trained community surgeons to see if these fractures can be treated successfully in either setting.

Using our hospital system's trauma database, we identified 100 consecutive patients treated with cephalomedullary nails by traumatologists, and 100 consecutive patients treated by community surgeons. Quality of reduction, neck shaft angle (NSA), tip-to apex distance (TAD) were compared.

The mean TAD for the trauma group was 10mm compared to 21mm for the community group (p<0.001). The mean postoperative NSA for the trauma group was 133 degrees compared to 127 degrees for the community group (p<0.001). The mean difference in the NSA of the fractured side compared to the normal hip was 2.5 degrees of valgus in the trauma group compared to 5 degrees of varus for the community group (p<0.001). There were 93 good reductions in the trauma group compared to 19 in the community group (p<0.001). There were no poor reductions in the trauma group and 49 poor reductions in the community group (p<0.001).

Fellowship trained traumatologists achieved significantly more accurate reductions and implant placement during cephalomedullary nailing of intertrochanteric hip fractures.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_11 | Pages 14 - 14
7 Jun 2023
Smeeton M Wilcox R Isaac G Anderson J Board T Van Citters DW Williams S
Full Access

Dual Mobility (DM) Total Hip Replacements (THRs) were introduced to reduce dislocation risk, which is the most common cause of early revision. The in-vivo mechanics of these implants is not well understood, despite their increased use in both elective and trauma settings. Therefore, the aim of this study was to comprehensively assess retrieved DM polyethylene liners for signs of damage using visual inspection and semi-quantitative geometric assessment techniques.

Retrieved DM liners (n=20) were visually inspected for the presence of seven established modes of polyethylene damage. If embedded debris was identified on the external surface, its material composition was characterised using energy-dispersive x-ray analysis (EDX). Additionally, each liner was geometrically assessed for signs of wear/deformation using a validated methodology.

Visual inspection of the liners revealed that scratching and pitting were the most common damage modes on either surface. Burnishing was observed on 50% and 15% of the internal and external surfaces, respectively. In addition, embedded debris was identified on 25% of the internal and 65% of the external surfaces. EDX analysis of the debris identified several materials including iron, titanium, cobalt-chrome, and tantalum. Geometric analysis demonstrated highly variable damage patterns across the liners.

The results of this study provide insight into the in-vivo mechanics of DM bearings. For example, the results suggest that the internal bearing (i.e., between the head and liner) acts as the primary articulation site for DM-THRs as evidenced by a higher incidence of burnishing and larger, more concentrated regions of penetration across the liners’ internal surfaces. Furthermore, circumferential, and crescent-shaped damage patterns were identified on the articulating surfaces of the liners thus providing evidence that these components can rotate within the acetabular shell with varying degrees of mobility. The mechanics of DM bearings are complex and may be influenced by several factors (e.g., soft tissue fibrosis, patient activities) and thus further investigation is warranted.

Finally, the results of this study suggest that DM liners may be susceptible to ex-vivo surface damage and thus caution is advised when handling and/or assessing these types of components.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_8 | Pages 119 - 119
11 Apr 2023
Peffers M Anderson J Jacobsen S Walters M Bundgaard L Hackle M James V
Full Access

Joint tissues release extracellular vesicles (EVs) that potentially sustain joint homeostasis and contribute to osteoarthritis (OA) pathogenesis. EVs are putative novel therapeutics for OA, and transport biologically active molecules (including small non-coding RNAs (SNCRNAs)) between cells. This study identified altering SNCRNA cargo in EVs in OA which may act as early diagnostic markers and treatment targets.

OA was surgically induced in four skeletally mature Standardbred horses using an osteochondral fragment model in the left middle carpal joint. The right joint underwent sham surgery. Synovial fluid (SF) and plasma were obtained weekly throughout the 70-day study. EVs were isolated using size exclusion chromatography and characterised using nanoparticle tracking (Nanosight), and exosome fluorescence detection and tetraspanin phenotyping (Exoview). RNA was extracted from EVs derived from SF (sham and OA joints) and plasma collected at days 10, 35, 42, 49, 56, 63, and subjected to small RNA sequencing on a NovaSeq SP100 flow cell (Illumina).

Nanosight-derived EV characteristics of size and concentration were not significantly different following disease induction. The diameter of the temporal population of plasma and SF-derived exosomes changed significantly for CD9 and CD81 following OA induction with significant temporal, and disease-related changes in CD63 and CD81 protein expressin in plasma and SF.

In SF and plasma-derived EVs snoRNAs, snRNAs, tRNAs, lncRNA, y-RNA, piRNAs and scRNA were found. Following pairwise analysis of all-time points we identified 27 miRs DE in plasma and 45 DE miRs in SF. Seven were DE in plasma and SF; miR-451, miR-25, miR-215, miR-92a, miR-let-7c, miR-486-5p, miR-23a. In plasma and SF 35 and 21 snoRNAs were DE with four DE in plasma and SF; U3, snord15, snord46, snord58.

This work has identified alterations to OA EV sncRNAs in plasma and SF providing a greater understanding of the role of EVs in early OA.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_7 | Pages 69 - 69
4 Apr 2023
Smeeton M Wilcox R Isaac G Anderson J Board T Van Citters D Williams S
Full Access

Dual mobility (DM) total hip replacements (THRs) were introduced to reduce dislocation risk, which is the most common cause of early revision. Although DM THRs have shown good overall survivorship and low dislocation rates, the mechanisms which describe how these bearings function in-vivo are not fully understood. Therefore, the study aim was to comprehensively assess retrieved DM polyethylene liners for signs of damage using visual inspection and semi-quantitative geometric assessment methods.

Retrieved DM liners (n=18) were visually inspected for the presence of surface damage, whereby the internal and external surfaces were independently assigned a score of one (present) or zero (not present) for seven damage modes. The severity of damage was not assessed. The material composition of embedded debris was characterised using energy-dispersive x-ray analysis (EDX). Additionally, each liner was geometrically assessed for signs of wear/deformation [1].

Scratching and pitting were the most common damage modes on either surface. Additionally, burnishing was observed on 50% of the internal surfaces and embedded debris was identified on 67% of the external surfaces. EDX analysis of the debris identified several materials including titanium, cobalt-chrome, iron, and tantalum. Geometric analysis demonstrated highly variable damage patterns across the liners.

The incidence of burnishing was three times greater for the internal surfaces, suggesting that this acts as the primary articulation site. The external surfaces sustained more observable damage as evidenced by a higher incidence of embedded debris, abrasion, delamination, and deformation. In conjunction with the highly variable damage patterns observed, these results suggest that DM kinematics are complex and may be influenced by several factors (e.g., soft tissue fibrosis, patient activities) and thus further investigation is warranted.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_3 | Pages 1 - 1
23 Feb 2023
Chong S Khademi M Reddy K Anderson G
Full Access

Treatment of posterior malleolar (PM) ankle fractures remain controversial. Despite increasing recommendation for small PM fragment fixation, high quality evidence demonstrating improved clinical outcomes over the unfixated PM is limited. We describe the medium-to-long term clinical and radiographical outcomes in younger adult patients with PM ankle fractures managed without PM fragment fixation.

A retrospective cohort study of patients aged 18-55 years old admitted under our orthopaedic unit between 1st of April 2009 and 31st of October 2013 with PM ankle fractures was performed. Inclusion criteria were that all patients must mobilise independently pre-trauma, have no pre-existing ankle pathologies, and had satisfactory bimalleolar and syndesmotic stabilisation. Open fractures, talar fractures, calcaneal fractures, pilon fractures, subsequent re-injury and major complications were excluded. All PM fragments were unfixated. Clinical outcomes were evaluated using Foot and Ankle Ability Measure (FAAM) with activities of daily living (ADL) and sports subscale, visual analogue scale (VAS) and patient satisfaction ratings. Osteoarthrosis was assessed using modified Kellgren-Lawrence scale on updated weightbearing ankle radiographs.

61 participants were included. Mean follow-up was 10.26 years. Average PM size was 16.19±7.39%. All participants were evaluated for clinical outcomes, demonstrating good functional outcomes (FAAM-ADL 95.48±7.13; FAAM-Sports 86.39±15.52) and patient satisfaction (86.16±14.42%), with minimal pain (VAS 1.13±1.65). Radiographical outcomes were evaluated in 52 participants, showing no-to-minimal osteoarthrosis in 36/52 (69.23%), mild osteoarthrosis in 14/52 (26.92%) and moderate osteoarthrosis in 2/52 (3.85%). Clinical outcomes were not associated with PM fragment size, post-reduction step-off, dislocation, malleoli fractured or syndesmotic injury. PM step-off and dislocation were associated with worse radiographical osteoarthrosis. Other published medium-to-long term studies reported overall good outcomes, with no differences after small fragment fixation.

The unfixated smaller posterior malleolus fragment demonstrated overall satisfactory clinical and radiographical outcomes at 10-year follow-up and may be considered a valid treatment strategy.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_2 | Pages 42 - 42
10 Feb 2023
Fary C Abshagen S Van Andel D Ren A Anderson M Klar B
Full Access

Advances in algorithms developed with sensor data from smart phones demonstrates the capacity to passively collect qualitative gait metrics. The purpose of this feasibility study was to assess the recovery of these metrics following joint reconstruction. A secondary data analysis of an ethics approved global, multicenter, prospective longitudinal study evaluating gait quality data before and after primary total knee arthroplasty (TKA, n=476), partial knee arthroplasty (PKA, n=139), and total hip arthroplasty (THA, n=395). A minimum 24 week follow-up was required (mean 45±12, range 24 - 78). Gait bouts and gait quality metrics (walking speed, step length, timing asymmetry, and double support percentage) were collected from a standardized smartphone operating system. Pre- and post-operative values were compared using paired-samples t-tests (p<0.05).

A total of 595 females and 415 males with a mean age of 61.9±9.3 years and mean BMI of 30.2±6.1 kg/m2 were reviewed. Walking speeds were lowest at post-operative week two (all, p<.001). Speeds exceeded pre-operative means consistently by week 21 (p=0.015) for PKA, and week 13 (p=0.007) for THA. The average weekly step length was lowest in post-operative week two (all, p<0.001). PKA and THA cases achieved pre-operative step lengths by week seven (p=0.064) and week 9 (p=0.081), respectively. The average weekly gait asymmetry peaked at week two post-operatively (all, p <0.001). Return to pre-operative baseline asymmetry was achieved by week 11 (p=0.371) for TKA, week six (p=0.541) for PKA, and week eight (p=.886) for THA. Double limb support percentages peaked at week two (all, p<0.001) and returned to pre-operative levels by week 24 (p=0.089) for TKA, week 12 (p=0.156) for PKA, and week 10 (p=0.143) for THA.

Monitoring gait quality in real-world settings following joint reconstruction using smartphones is feasible, and may provide the advantage of removing the Hawthorne effect related to typical gait assessments and in-clinic observations.


Bone & Joint Open
Vol. 3, Issue 10 | Pages 753 - 758
4 Oct 2022
Farrow L Clement ND Smith D Meek DRM Ryan M Gillies K Anderson L Ashcroft GP

Aims

The extended wait that most patients are now experiencing for hip and knee arthroplasty has raised questions about whether reliance on waiting time as the primary driver for prioritization is ethical, and if other additional factors should be included in determining surgical priority. Our Prioritization of THose aWaiting hip and knee ArthroplastY (PATHWAY) project will explore which perioperative factors are important to consider when prioritizing those on the waiting list for hip and knee arthroplasty, and how these factors should be weighted. The final product will include a weighted benefit score that can be used to aid in surgical prioritization for those awaiting elective primary hip and knee arthroplasty.

Methods

There will be two linked work packages focusing on opinion from key stakeholders (patients and surgeons). First, an online modified Delphi process to determine a consensus set of factors that should be involved in patient prioritization. This will be performed using standard Delphi methodology consisting of multiple rounds where following initial individual rating there is feedback, discussion, and further recommendations undertaken towards eventual consensus. The second stage will then consist of a Discrete Choice Experiment (DCE) to allow for priority setting of the factors derived from the Delphi through elicitation of weighted benefit scores. The DCE consists of several choice tasks designed to elicit stakeholder preference regarding included attributes (factors).


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_16 | Pages 18 - 18
1 Dec 2021
Brown M Wilcox R Isaac G Anderson J Board T Williams S
Full Access

Abstract

OBJECTIVES

Dual mobility (DM) total hip replacements (THRs) were introduced to reduce the risk of hip dislocation in at-risk patients. DM THRs have shown good overall survivorship and low rates of dislocation, however, the mechanisms which describe how these bearings function in-vivo are not fully understood. This is partly due to a lack of suitable characterisation methodologies which are appropriate for the novel geometry and function of DM polyethylene liners, whereby both surfaces are subject to articulation. This study aimed to develop a novel semi-quantitative geometric characterisation methodology to assess the wear/deformation of DM liners.

METHODS

Three-dimensional coordinate data of the internal and external surfaces of 14 in-vitro tested DM liners was collected using a Legex 322 coordinate measuring machine. Data was input into a custom Matlab script, whereby the unworn reference geometry was determined using a sphere fitting algorithm. The analysis method determined the geometric variance of each point from the reference surface and produced surface deviation heatmaps to visualise areas of wear/deformation. Repeatability of the method was also assessed.


Bone & Joint Open
Vol. 2, Issue 7 | Pages 530 - 534
14 Jul 2021
Hampton M Riley E Garneti N Anderson A Wembridge K

Aims

Due to widespread cancellations in elective orthopaedic procedures, the number of patients on waiting list for surgery is rising. We aim to determine and quantify if disparities exist between inpatient and day-case orthopaedic waiting list numbers; we also aim to determine if there is a ‘hidden burden’ that already exists due to reductions in elective secondary care referrals.

Methods

Retrospective data were collected between 1 April 2020 and 31 December 2020 and compared with the same nine-month period the previous year. Data collected included surgeries performed (day-case vs inpatient), number of patients currently on the orthopaedic waiting list (day-case vs inpatient), and number of new patient referrals from primary care and therapy services.


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_9 | Pages 14 - 14
1 Jun 2021
Anderson M Lonner J Van Andel D Ballard J
Full Access

Introduction

The purpose of this study was to demonstrate the feasibility of passively collecting objective data from a commercially available smartphone-based care management platform (sbCMP) and robotic assisted total knee arthroplasty (raTKA).

Methods

Secondary data analysis was performed using de-identified data from a commercial database that collected metrics from a sbCMP combined with intraoperative data collection from raTKA. Patients were included in this analysis if they underwent unilateral raTKA between July 2020 and February 2021, and were prescribed the sbCMP (n=131). The population consisted of 76 females and 55 males, with a mean age of 64 years (range, 43 – 81). Pre-operative through six-week post-operative data included step counts from the sbCMP, as well as administration of the KOOS JR. Intraoperative data included surgical times, the hip-knee-ankle angle (HKA), and medial and lateral laxity assessments from the robotic assessment. Data are presented using descriptive statistics. Comparisons were performed using a paired samples t-test, or Wilcoxon Signed-rank test, with significance assessed at p<0.05. A minimal detectable change (MDC) in the KOOS JR score was considered ½ standard deviation of the preoperative values.


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_9 | Pages 15 - 15
1 Jun 2021
Anderson M Van Andel D Israelite C Nelson C
Full Access

Introduction

The purpose of this study was to characterize the recovery of physical activity following knee arthroplasty by means of step counts and flight counts (flights of stairs) measured using a smartphone-based care platform.

Methods

This is a secondary data analysis on the treatment cohort of a multicenter prospective trial evaluating the use of a smartphone-based care platform for primary total and unicondylar joint arthroplasty. Participants in the treatment arm that underwent primary total or unicondylar knee arthroplasty and had at least 3 months of follow-up were included (n=367). Participants were provided the app with an associated smart watch for measuring several different health measures including daily step and flight counts. These measures were monitored preoperatively, and the following postoperative intervals were selected for review: 2–4 days, 1 month, 1.5 month, 3 months and 6 months. The data are presented as mean, standard deviation, median, and interquartile range (IQR). Signed rank tests were used to assess the difference in average of daily step counts over time. As not all patients reported having multiple stairs at home, a separate analysis was also performed on average flights of stairs (n=214). A sub-study was performed to evaluate patients who returned to preoperative levels at 1.5 months (step count) and 3 months (flight count) using an independent samples T test or Fisher's Exact test was to compare demographics between patients that returned to preoperative levels and those that did not.


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_9 | Pages 13 - 13
1 Jun 2021
Anderson M Van Andel D Foran J Mance I Arnold E
Full Access

Introduction

Recent advances in algorithms developed with passively collected sensor data from smart phones and watches demonstrate new, objective, metrics with the capacity to show qualitative gait characteristics. The purpose of this feasibility study was to assess the recovery of gait quality following primary total hip and knee arthroplasty collected using a smartphone-based care platform.

Methods

A secondary data analysis of an IRB approved multicenter prospective trial evaluating the use of a smartphone-based care platform for primary total knee arthroplasty (TKA, n=88), unicondylar knee arthroplasty (UKA, n=28), and total hip arthroplasty (THA, n=82). Subjects were followed from 6 weeks preoperative to 24 weeks postoperative. The group was comprised of 117 females and 81 males with a mean age of 61.4 and BMI of 30.7. Signals were collected from the participants' smartphones. These signals were used to estimate gait quality according to walking speed, step length, and timing asymmetry. Post-operative measures were compared to preoperative baseline levels using a Signed-Rank test (p<0.05).


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_10 | Pages 56 - 56
1 Oct 2020
Lombardi AV Berend KR Huddleston J Crawford D Peters C VanAndel D Anderson M DeHaan A Southgate R Duwelius PJ
Full Access

Background

The purpose of this study is to evaluate the early outcomes with the use of a smartphone-based exercise and educational platform after primary total hip arthroplasty compared to a standard of care control group.

Methods

A multicenter prospective randomized control trial was conducted evaluating the use of the mymobility smartphone-based care platform for primary total hip arthroplasty (THA). Patients randomized to the control group (198 patients) received the respective institution's standard of care. Those randomized to mymobility treatment group (167 patients) were provided an Apple Watch and mymobility smartphone application. The application provides pre and postoperative educational content, video directed exercise programs as well as tracks the patient's activity. Patients in the treatment group were not initially prescribed physical therapy, but could be if their surgeon deemed it necessary. Early outcomes assessed included 90-day hip range of motion, HOOS JR scores, 30-day single leg stance (SLS) and time up and go (TUG) test.

We also evaluated PT utilization, THA complications associated with readmissions, ER visits not associated with readmissions, urgent care (non standard of care) visits, and physician office visits.

Outcome scores include HOOS-Jr, EQ-5D-5L, single stance (SLS), Timed up and go (TUG).

Satisfaction scores for the procedure and the mymobility study group were also recorded.


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_9 | Pages 55 - 55
1 Oct 2020
Mahan C Blackburn B Anderson LA Peters CL Pelt CE Gililland JM
Full Access

Introduction

Porous metaphyseal cones are increasingly used for fixation in revision total knee arthroplasty (RTKA). Both cemented shorter length stems and longer diaphyseal engaging stems are currently utilized with metaphyseal cones with no clear evidence of superiority. The purpose of this study was to evaluate our experience with 3D printed titanium metaphyseal cones with both short cemented and longer cementless stems from a clinical and radiographic perspective.

Methods

In total 136 3D printed titanium metaphyseal cones were implanted. The mean patient age was 63 and 48% were female. The mean BMI was 33 and the mean ASA class was 2.5. There were 42 femoral cones in which 28 cemented and 14 cementless stems were utilized. There were 94 tibial cones in which 67 cemented and 27 cementless stems were utilized. The choice for stem fixation was surgeon dependent and in general cones were utilized for AORI type 2 and 3 bone defects on the femur and tibia. The most common fixation scenario was short cemented stems on both the femur and tibia followed by cemented stem fixation on the tibia and cementless fixation on the femur. Clinical data such as revision, complication, and PRO was collected at last follow-up (minimum follow-up 1 year). Radiographic analysis included cone bony ingrowth and coronal and sagittal alignment on long-standing radiographs. Descriptive statistics were used to compare demographics between patients who had malalignment (HKA beyond +/− 3 degrees and flexion/extension beyond +/− 3 degrees). Adjusted logistic regression models were run to assess malalignment risk by stem type.


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_10 | Pages 16 - 16
1 Oct 2020
Anderson LA Wylie J Erickson JA Peters CL
Full Access

Introduction

Periacetabular osteotomy (PAO) is the preferred treatment for symptomatic acetabular dysplasia in adolescents and young adults. There remains a lack of consensus regarding whether intra-articular work such as labral repair or improvement of femoral offset should be performed at the time of PAO or addressed subsequent to PAO if symptoms warrant. The purpose of this review was to determine the rate of subsequent hip arthroscopy (HA) in a contemporary PAO cohort with no intra-articular work performed at the time of PAO.

Methods

From June 2012 to September 2019, 272 Rectus Sparing PAOs were performed and followed for a minimum of one year (mean 4.6 years). The average age was 24 (range 14–44) and 87% were female. The average BMI was 25 and average length of hospital stay was 2.9 days. Patients were evaluated at last follow-up with PROMIS PF-CAT, pain and mental health scores. Clinical records were reviewed for complications or subsequent surgery. Pre and post-operative radiographs were reviewed for change in the following acetabular parameters: LCEA, ACEA, AI, and the alpha-angle was obtained from preoperative radiographs. Patients were cross-referenced from the two largest hospital systems in our area to determine if subsequent HA was performed. Descriptive statistics and logistic regression were used to analyze risk factors for HA.


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_8 | Pages 72 - 72
1 Aug 2020
Gagne O Symes M Abbas KZ Penner M Wing K Younger A Syed K Lau J Veljkovic A Anderson L
Full Access

Patients' perspective and experience is heavily modulated by their understanding of their pre-operative disability along with their overall coping strategy and life philosophy. Given that evidence-based practice is relying on patient-reported outcomes more and more, the orthopaedic community must be diligent in differentiating patients that may have the same objective outcome but vary widely on a patient-reported subjective basis. In clinical practice, patient selection is often a sensitive, experience-based decision process that screens for catastrophization, recognizing that certain patients will not benefit from a simple surgery. It is well appreciated that patient's catastrophization can affect their subjective outcome but there is little reported literature on this abstract concept. The study set out to determine if post-operative outcomes correlated with pre-operative catastrophization scales.

This current study set out to look at a cohort of complex consecutive foot and ankle cases and describe the relationship between Patient Catastrophizing Score (PCS) and multiple functional outcomes that are used commonly in foot and ankle specifically (SF-12 & FAOS). The PCS has three subcategory rumination, helplessness and magnification. A single institution undertook recruitment in consecutive patients within three surgeon's practice. In the end, 46 patients were found to be eligible in the study with an average age of 54.72 ± 14.41 years-old, a majority female 30 / 46 (65.22%), a minority employed at the pre-operative visit 19/46 (41%) and with an average BMI of 26.2 ± 5.56.

We found that the mental component of the SF12 had a statistically significant negative effect with the rumination score (r=−1.03) (p = 0.01) and the helplessness score (r=−1.05) (0.001). There was no statistically significant effect for the physical component of the SF-12. Looking at the FAOS Pain component, it correlated was significantly with the PCS rumination (Multivariate : r= −7.6 (p=0.002) Univariate: r=−2 (0.03)) and helplessness (Multivariate : r=−6.73 (p=0.01) Univariate: r=−1.5 (p=0.03)). Otherwise the FAOS ADL component showed correlation as well with the PCS rumination (Multivariate: r=−4.67 (p=0.02) Univariate : r=−1.85 (p=0.01)), helplessness (Multivariate r=−5.89 (p = 0.01) Univariate r=−1.81 (p = 0.001)) and total score (Multivariate : r=3.74 (p=0.02) Univariate r=−0.75 (p=0.01)). The FAOS Quality of life component was statistically significant for the rumination score (Univariate r=−11.59) (p < 0.05) and the helplessness score (Univariate r=−9.65) (p = 0.002) also the PCS total (Univariate r=8.54) (p = 0.0003).

As layed out in our hypothesis, this study did show an association between an increase patient catastrophizing score pre-operatively and a worse outcome in the following scores: Mental component of SF12, FAOS Pain, FAOS ADL and FAOS Quality of life components. This is an association and no causality can be proven within the limits of this current pilot study, but remains alarming. In elective surgeries, catastrophization should be screened for using the PCS form and potentially modulated pre-operatively with the help of allied health therapist while a patient is on the waitlist.


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_12 | Pages 48 - 48
1 Oct 2019
Anderson L Erickson J Peters CL
Full Access

Introduction

Radiographic assessment of acetabular fragment positioning during periacetabular osteotomy (PAO) is of paramount importance. Plain radiographic examination is time and resource intensive. Fluoroscopic based assessment is increasingly utilized but can introduce distortion. Our purpose was to determine the correlation of intraoperative fluoroscopy-based measurements with a fluoroscopic tool that corrects for distortion with postoperative plain-film measurements.

Methods

We performed a prospective validation study on 32 PAO's (28 patients) performed by a single academic surgeon. Preoperative standing radiographs, intraoperative fluoroscopic images, and postoperative standing radiographs were evaluated with lateral center edge angle (LCEA), acetabular index (AI), posterior wall sign (PWS), and anterior center edge angle (ACEA). Intraoperative fluoroscopy was adjusted to account for pelvic inclination. The fluoroscopic GRID was utilized in all cases (Phantom MSK Hip Preservation, OrthoGrid LLC, Salt Lake City, UT). Intraoperative fluoroscopic measurements were compared to preoperative and postoperative standing radiographs at 6 weeks using linear regression applied in MINITAB.


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_12 | Pages 70 - 70
1 Oct 2018
Wodowski AJ Pelt CE Erickson J Anderson M Gililland J Peters CL Duensing I
Full Access

Introduction

Recent studies of novel healthcare episode payment models, such as the Bundled Payments for Care Improvement (BPCI) initiative, have demonstrated pathways for improving value. However, these models may not provide appropriate payments for patients with significant medical comorbidities or complications. The objective of this study was to identify risk factors for exceeding our institution's target payment, the so-called “bundle busters.”

Methods

After receiving an exemption from the Institutional Review Board, we queried our institutional data warehouse for all patients (n=412) that underwent total joint arthroplasty (TJA) of the hip (n=192), knee (n=207), or ankle (n=13), and qualified for our institution's bundled payments model during the study time period (July 2015 – May 2017). Patients with medical conditions that were not well controlled or were potentially optimizable were all sent for preoperative medical optimization prior to surgery. For each 90-day episode, patient characteristics, medical comorbidities, perioperative data, and payments from the Centers for Medicare and Medicaid Services (CMS) were obtained. Episodes where Medicare payments exceeded the target payment were considered “busters”. The busters were older, and had higher comorbidity scores (all, p<0.01). Variables were summarized using descriptive statistics and risk ratios were calculated using a modified Poisson regression analysis.


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_13 | Pages 3 - 3
1 Oct 2018
Peters CL Anderson MB Erickson JA Anderson LA
Full Access

Introduction

The aim of this study was to compare patient reported outcomes, radiographic measurements, and survival free from total hip arthroplasty (THA) in patients who underwent periacetabular osteotomy (PAO) for mild, moderate, or severe developmental dysplasia of the hip (DDH).

Methods

We performed a retrospective cohort study on all patients (n=223, n=274 hips) who underwent a PAO procedure between May 1996 and May 2016, by a single surgeon at one academic center. Cases with a history of retroversion (n=64), Perthes (n=5), and those with <2 years of follow-up (n=63) were excluded. Patients were evaluated based on severity of dysplasia using the preoperative lateral center edge angle (LCEA): 18° – 25° was considered mild dysplasia (n=19), 10° – 17° moderate (n=62), and <10° severe (n=61). There was no difference in patient characteristics (age, sex, body mass index, or ASA score) between then cohorts (all, p>0.05). NIH PROMIS outcome measures included the physical function computerized adaptive test (PF CAT) and the Global 10 health assessment. Generalized estimating equations were used for all comparisons and missing data was imputed using the multivariate imputation by chained equations method. A Kaplan-Meier analysis was used to assess survival. Failure was defined as conversion to THA and follow-up was ended at time of failure or at the time of last follow-up. Mean follow-up was five years (1 – 19).


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_6 | Pages 60 - 60
1 Apr 2018
Anderson C Golladay G Roche M Gustke K Elson L
Full Access

Introduction & Aims

The traditional method of soft-tissue balancing during TKA is subjective in nature, and stiffness and instability are common indications for revision, suggesting that TKA balancing by subjective assessment is suboptimal. This study examines the intraoperative mediolateral loads measured with a nanosensor-enabled tibial insert trial and the sequential balancing steps used to achieve quantitative balance. Data obtained from a prospective multicenter study was assessed to determine the effect of targeted ligament release on intra-articular loading, and to understand which types of releases are necessary to achieve quantified ligament balance.

Methods

A group of 129 patients received sensor-assisted TKA, as part of a prospective multicenter study. Medial and lateral loading data were collected pre-release, during any sequential releases, and post-release. All data were collected at 10, 45, and 90 degrees during range of motion testing. Ligament release type, release technique type, and resultant loading were collected.


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_5 | Pages 18 - 18
1 Apr 2018
Preutenborbeck M Holub O Anderson J Jones A Hall R Williams S
Full Access

Introduction

Up to 60% of total hip arthroplasties (THA) in Asian populations arise from avascular necrosis (AVN), a bone disease that can lead to femoral head collapse. Current diagnostic methods to classify AVN have poor reproducibility and are not reliable in assessing the fracture risk. Femoral heads with an immediate fracture risk should be treated with a THA, conservative treatments are only successful in some cases and cause unnecessary patient suffering if used inappropriately. There is potential to improve the assessment of the fracture risk by using a combination of density-calibrated computed tomographic (QCT) imaging and engineering beam theory. The aim of this study was to validate the novel fracture prediction method against in-vitro compression tests on a series of six human femur specimens.

Methods

Six femoral heads from six subjects were tested, a subset (n=3) included a hole drilled into the subchondral area of the femoral head via the femoral neck (University of Leeds, ethical approval MEEC13-002). The simulated lesions provided a method to validate the fracture prediction model with respect of AVN.

The femoral heads were then modelled by a beam loaded with a single joint contact load. Material properties were assigned to the beam model from QCT-scans by using a density-modulus relationship. The maximum joint loading at which each bone cross-section was likely to fracture was calculated using a strain based failure criterion.

Based on the predicted fracture loads, all six femoral heads (validation set) were classified into two groups, high fracture risk and low fracture risk (Figure 1). Beam theory did not allow for an accurate fracture load to be found because of the geometry of the femoral head. Therefore the predicted fracture loads of each of the six femoral heads was compared to the mean fracture load from twelve previously analysed human femoral heads (reference set) without lesions.

The six cemented femurs were compression tested until failure. The subjects with a higher fracture risk were identified using both the experimental and beam tool outputs.


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_6 | Pages 51 - 51
1 Apr 2018
Avadi MS Meng L Anderson J Fisher J Wang M Jin Z Qiu Y Williams S
Full Access

INTRODUCTION

Avascular necrosis (AVN) of the femoral head (FH) initiates from biological disruptions in the bone and may progress to mechanical failure of the hip. Mechanical and structural properties of AVN bone have not been widely reported, however such understanding is important when designing therapies for AVN. Brown et al.[1] assessed mechanical properties of different regions of AVN FH bone and reported 52% reduction in yield strength and 72% reduction in elastic modulus of necrotic regions when compared to non-necrotic bone. This study aimed to characterise structural and mechanical properties of FH bone with AVN and understand the relationship between lesion volume and associated mechanical properties.

METHODS

Twenty FH specimens from patients undergoing hip arthroplasty for AVN and six non-pathological cadaveric FH controls were collected. Samples were computed tomography scanned and images analysed for percentage lesion volume with respect to FH volume. Samples were further divided for structural and mechanical testing. The mechanical property group were further processed to remove 9mm cylindrical bone plugs from the load bearing and non-load-bearing regions of the FHs. FH and bone plug samples were tested in compression (1mm/min); elastic modulus and yield stress were calculated.


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_1 | Pages 50 - 50
1 Jan 2018
Makarewich CA Christensen M Anderson M Gililland J Pelt C Peters C
Full Access

Total hip arthroplasty (THA) in the young patient has been associated with higher rates of revision and perioperative complications. For clinicians and patients alike, there remains a desire to better characterize the durability of THA in young patients. We reviewed secondary data from our institutional database for all patients who underwent primary THA from January 2000 to May 2015. Patients were identified using ICD-9 procedure code 81.51. Our primary interest was the survival of implants in patients 30 years of age or younger (n=167) while using a contemporaneous cohort of patients age 60 and older as a control (n=1359). Failure was defined as revision THA for any reason. Cox regression with robust standard errors was used to calculate hazard ratios. A population-averaged Poisson regression analysis was used to compare complication rates.

The rate of all-cause revision THA was 2.4 times greater (95% CI 1.10 – 5.37, p=0.028) in young patients (7%, 12/167) undergoing primary or conversion to THA compared to their elderly counterparts (3.7%, 50/1,359). Survival at 10 years was 89% (95% CI 82 – 94) in the young cohort and 96% (94 – 97) in the elderly cohort. The primary reasons for revision in young that patients compared to their elderly counterparts included metal-on-metal implants (IRR 8.12, 95% CI 2.04 – 32.38, p=0.003).

These data demonstrate that patients 30 years of age and younger substantially benefit from THA but should be warned of higher risk of subsequent revision.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_22 | Pages 29 - 29
1 Dec 2017
Anderson R Bates-Powell J Cole C Kulkarni S Moore E Norrish A Nickerson E
Full Access

Aim

This study aimed to evaluate the impact on length of hospital stay from dedicated infectious diseases input for orthopaedic infection patients compared to sporadic infection specialist input.

Method

We conducted an observational cohort study of 157 adults with orthopaedic infections at a teaching hospital in the UK. The orthopaedic infections included were: osteomyelitis, septic arthritis, infected metalwork and prosthetic joint infections, and adults were aged 18 years or more. Prior to August 2016, advice on orthopaedic infection patients was adhoc with input principally from the on-call infectious diseases registrar and phone calls to microbiology whereas after August 2016 these patients received regular input from dedicated infectious diseases doctor(s). The dedicated input involved bedside reviews, medical management, correct antimicrobial prescribing, managing adverse drug reactions, increased use of outpatient parenteral antimicrobial therapy (OPAT) services especially self-administration of intravenous antibiotics and shared decision-making for treatment failure, whilst remaining under orthopaedic team care. Orthopaedic patients operated on for management of their infection between 29/8/16 and 15/3/17 were prospectively identified and orthopaedic operation records were used to retrospectively identified patients between 29/8/15 and 15/3/16. The length of stay was compared between the 2 groups.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_4 | Pages 119 - 119
1 Feb 2017
Anderson C Golladay G Roche M Gustke K Leone W
Full Access

Total knee arthroplasty (TKA) is currently one of the most common elective surgical procedures in the United States. The increase in the proportion of younger patients in receipt of surgery, in concert with a dramatic rise in the incidence of obesity, has contributed to the on-going, exponential increase in the number of arthroplasties performed annually. Despite materials advances for implants, the U.S. revision burden has remained static for the last decade. According to the 2013 CMS MEDPAR file the typical CMS reimbursement falls far short of costs incurred by the hospital, resulting in an average net loss of revenue of $9,539; and over 90% of hospitals lose money for every revision case performed. Today, approximately 5% of all primaries performed will result in an early revision (< 3 years). In order to understand ways with which to mitigate the incidence of early revision due to mechanical complications, a multicentric group of sensor-assisted patients was follow-up out to 3 years.

In this study, 278 sensor-assisted patients were followed out to 3 years. The intraoperative devices used in this study contain microsensors and a processing unit. Kinetic and center of load location data are projected, in real-time, to a screen. Because of the wireless nature of the intraoperative sensors, the patella can be reduced, and kinematic data can be evaluated through the range of motion. For each patient, the soft-tissue envelope was balanced to within a mediolateral differential of 15 lbf., through the ROM, as per the suggestion of previously reported literature. The average patient profile indicates: age = 69.7 years, BMI = 30.4, gender distribution = 36% male/64% female. Any adverse event within the 3-year follow-up interval was captured.

By 3 years, 1 patient in this population has required revision surgeon due to mechanical complicatons. Overall adverse events included: pain in hip (3), pain in contralateral knee (2), wound drainage (3), DVT (1), death (1), stiffness in operative knee (2), infection (3), global pain (2), back pain (2).

Based on the average reported number of early revisions that occur in the U.S. (5% of primaries), it was anticipated for this patient group to require approximately 13 revisions by the 3-year follow-up interval. Using 2013 CMS MEDPAR data, these 13 revisions would have resulted in $124,007 cost-to-hospital. However, only 1 revision (0.4%) was observered, therefore $114,468 in additional costs were spared for the aggregate of participating hospitals. This data suggests that the incorporation of kinetic sensors in TKA may assist the surgeon in achieving soft-tissue balance and thereby avoiding adverse mechanical complications that require surgical intervention.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_4 | Pages 4 - 4
1 Feb 2017
Anderson C Gustke K Roche M Golladay G Jerry G Elson L
Full Access

Total knee arthroplasty (TKA) patients are consistently reported to be less satisfied than total hip arthroplasty (THA) patients. A patient's perception of success of his/her own total knee is dictated by their levels of post-operative pain and function, and many return to follow-up visits with inexplicable pain and stiffness that contradict favorable radiographic results. Several of these chief complaints that contribute to dissatisfaction are associated with soft-tissue imbalance. Therefore, in an effort to thoroughly understand the post-operative impact of soft-tissue balance on satisfaction, a multicenter study was conducted to evaluate the satisfaction outcomes of quantifiably balanced patients.

In this study, 102 sensor-assisted patients were followed out to 3 years. The intraoperative devices used in this study project kinetic loading (lbf.) and center of load location data, in real-time, to a screen. Because of the wireless nature of the intraoperative sensors, the patella can be reduced, and kinematic data can be evaluated through the range of motion. The target balance window that was used in this study has been previously reported in literature and includes: 1) a mediolateral differential of 15 lbf., through the ROM, and 2) Sagittal plane stability as determined by a posterior drawer analysis. A robust, face-validated satisfaction survey was administered at 3-year follow-up and included 7 questions with answers on a 5-point Likert scale.

At 3 years, post-operatively, 97.2% of this patient group reported being “satisfied” to “very satisfied” with their procedure, in comparison to the 81% average TKA satisfaction reported in literature (df = 11). The comparative literature included annual satisfaction intervals from 1 to 5 years (n = 33,775) which is comparable to the interval reported in this patient group. The sensor-assisted patient group exhibited a 16% increase in the proportion of satisfaction over what is currently reported in the comparative literature (p = 0.001).

Despite the success rate of TKA, unfavorable patient-reported satisfaction continues to present a problem for operative recipients and surgeons. Because satisfaction is dependent upon several variables – including pain, function, and activity levels – the satisfaction survey used in this study represents a more accurate account of patient perception than many traditional surveys. It was shown that sensor-balanced TKA patients exhibited a 16% increase in the proportion of those reporting being “satisfied” to “very satisfied”, over the average satisfaction reported in literature. Allowing the surgeon to quantitatively balance the soft-tissue envelope, dynamically, has continued to a significant decrease in the proportion of dissatisfaction.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_20 | Pages 49 - 49
1 Nov 2016
Sermer C Kandel R Hurtig M Anderson J Theodoropoulos J
Full Access

Osteoarthritis (OA) is a debilitating disease characterised by degradation of articular cartilage and subchondral bone remodeling. Current therapies for early or midstage disease do not regenerate articular cartilage, or fail to integrate the repair tissue with host tissue, and therefore there is great interest in developing biological approaches to cartilage repair. We have shown previously that platelet-rich plasma (PRP) can enhance cartilage tissue formation. PRP is obtained from a patient's own blood, and is an autologous source of many growth factors and other molecules which may aid in healing. This raised the question as to whether PRP could enhance cartilage integration. We hypothesise that PRP will enhance integration of bioengineered cartilage with native cartilage.

Chondrocytes were isolated from bovine metacarpal-phalangeal joints, seeded on a porous bone substitute (calcium polyphosphate) and grown in the presence of FBS to form an in vitro model of osteochondral-like tissue. After 7 days, the biphasic constructs were soaked in PRP for 30 minutes prior to implantation into the core of a ring-shaped biphasic explant of native bovine cartilage and bone. Controls were not soaked in PRP. The resulting implant-explant construct was cultured in a stirring bioreactor in serum free conditions for 2 weeks. The integration zone was visualised histologically. A push-out test was performed to assess the strength of integration. Matrix accumulation at the zone of integration was assessed biochemically and the gene expression of the cells in this region was assessed by RT-PCR. Significance (p<0.05) was assessed by a student's t-test or one-way ANOVA with tukey's post hoc.

PRP soaked bioengineered implants, integrated with the host tissue in 73% of samples, whereas control bioengineered implants only integrated in 19% of samples based on macroscopic evaluation (p<0.05). The integration strength, as determined by the normalised maximum force to failure, was significantly increased in the PRP soaked implant group compared to controls (219 +/− 35.4 kPa and 72.0 +/− 28.5 kPa, respectively, p<0.05). This correlated with an increase in glycosaminoglycan and collagen accumulation in the region of integration in the PRP treated implant group, compared to untreated controls after 2 weeks (p<0.05). Immunohistochemical studies revealed that the integration zone was rich in collagen type II and aggrecan. The cells at the zone of integration in the PRP soaked group had a 2.5 fold increase in aggrecan gene expression (p=0.05) and a 3.5 fold increase in matrix metalloproteinase 13 expression (p<0.05) compared to controls.

PRP soaked bio-engineered cartilage implants showed improved integration with native cartilage compared to non-treated implants, perhaps due to the increased matrix accumulation and remodeling at the interface. Further evaluation is required to determine if PRP improves integration in vivo.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_16 | Pages 22 - 22
1 Oct 2016
Ramakrishnan P Maclean M MacGregor SJ Anderson J Grant MH
Full Access

Healthcare associated infections (HAI) pose a major threat to patients admitted to hospitals, and infection rates following orthopaedic arthroplasty surgery are as high as 4%, while the infection rates are even higher after revision surgery. 405 nm High-Intensity Narrow Spectrum (HINS) light has been proven to reduce environmental contamination in hospital isolation rooms, and there is potential to develop this technology for application in orthopaedic surgery.

Cultured rat osteoblasts were exposed to 405 nm light to investigate if bactericidal doses of light could be used safely in the presence of mammalian cells. Cell viability was measured by MTT reduction and microscopy techniques, function by alkaline phosphatase activity, and proliferation by the BrdU assay. Exposures of up to a dose of 36 J/cm2 had no significant effect on osteoblast cell viability, whilst exposure of a variety of clinically relevant bacteria, to 36 J/cm2 resulted in up to 100% kill. Exposure to a higher dose of 54 J/cm2 significantly affected the osteoblast cell viability, indicating dose dependency.

Work also demonstrated that 405 nm light exposure induces reactive oxygen species (ROS) production in both mammalian and bacterial cells, as shown by fluorescence generated from 6-carboxy-2′,7′-dichlorodihydrofluorescein diacetate dye. The mammalian cells were significantly protected from dying at 54 J/cm2 by catalase, which detoxifies H2O2. Bacterial cells were significantly protected by sodium pyruvate (H2O2 scavenger) and by a combination of free radical scavengers (sodium pyruvate, dimethyl thiourea (·OH scavenger), catalase) at 162 and 324 J/cm2. Thus the cytotoxic mechanism of 405 nm light in mammalian cells and bacteria is likely oxidative stress involving predominantly H2O2 generation, with other ROS contributing to the damage.

Additional work describing the potential for incorporation of this antimicrobial light within operating theatre lighting systems will also be discussed, and this, coupled with the cell viability and cytotoxicity results, suggests that 405 nm light could have great potential for continual patient safe decontamination during orthopaedic replacement surgeries and thereby reduce the incidence of infections.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_16 | Pages 35 - 35
1 Oct 2016
Asif I Williams S Fisher J Al-Hajjar M Anderson J Tipper J
Full Access

Wear particles produced by alumina ceramic-on-ceramic (CoC) bearings cause a minimal immunological response with low cytotoxicity and inflammatory potential1, 2. However, more comprehensive immunological studies are yet to be completed for the composite CoC (zirconia-toughened, platelet reinforced alumina) hip replacements due to difficulties in isolating the very low volume of clinically relevant wear debris generated by such materials in vitro. The aim of this study was to compare the cytotoxic effects of clinically relevant cobalt chromium (CoCr) nano-particles with commercial composite ceramic particles.

Composite ceramic particles (commercial BIOLOX® delta powder) were obtained from CeramTec, Germany and clinically relevant CoCr wear particles were generated using a six station pin-on-plate wear simulator. L929 fibroblast cells were cultured with 50µm3 of CoCr wear debris or composite ceramic particles at low to high volumes ranging from 500µm3–0.5µm3 per cell and the cyctotoxic effects of the particles were assessed over a period of 6 days using the ATP-Lite™ cell viability assay.

The composite ceramic particles were bimodal in size (0.1–2µm & 30–100nm) and showed mild cytotoxic effects when compared with equivalent particle volumes (50µm3) of clinically relevant CoCr nano-particles (10–120nm). The CoCr nano-particles had significant cytotoxic effects from day 1, whereas the composite ceramic particles only showed cytotoxic effects at particle concentrations of 50 and 500µm3 after 6 days. The increased cytotoxicity of the clinically relevant CoCr nano-particles may have been attributed to the release of Co and Cr ions.

This study demonstrated the potential cytotoxic effects of model ceramic particles at very high volume concentrations, but it is unlikely that such high particle volumes will be experienced routinely in vivo in such low wearing bearing materials. Future work will investigate the longer-term effects on genotoxicity and oxidative stress of low volumes of clinically-relevant generated BIOLOX® delta ceramic wear particles.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_10 | Pages 3 - 3
1 May 2016
Elson L Leone W Roche M Anderson C
Full Access

Introduction

The rate of technological innovation in procedural total knee arthroplasty has left little time for critical evaluation of a new technology before the adoption of even newer modalities. With more drastic financial restrictions being placed on operating room spending, orthopaedic surgeons are now required to provide excellent results on a budget.

It is integral that both clinical efficacy and cost-effectiveness of these intraoperative technologies be fully understood in order to provide patients with effectual, economically conscious care. The purpose of this qualitative analysis of literature was to evaluate clinical and economic efficacy of the three most prominent technologies currently used in TKA: computer navigation, patient-specific instrumentation, and kinetic sensors.

Methods

Three hundred and ninety one publications were collected; 100 were included in final qualitative analysis. Criteria for inclusion in the analysis was defined only insofar as that each piece assessed one of the above listed aspects of the three technologies Literature included in the final evaluation contained background information on each respective technology, clinical outcomes, revision rates, and/or cost analyses. All comparisons were conducted in a strictly qualitative manner, and no attempts were made to conduct interstudy statistical analyses due to the high level of variability in methodology and data collected.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_10 | Pages 2 - 2
1 May 2016
Elson L Roche M Golladay G Anderson C
Full Access

Introduction

Instability after total knee arthroplasty (TKA) represents, in excess of, 7% of reasons for implant failure. This mode of failure is correlated with soft-tissue imbalance, and has continued to be problematic despite advances in implant technology. Thus, understanding the options available to execute safe and effective soft-tissue release is critical to mitigating future complications due to instability. This study aimed to use intraoperative sensors to evaluate a multiple needle puncturing technique (MNPT), in comparison with traditional transection-based release, to determine its biomechanical and clinical efficacy.

Methods

Seventy-five consecutive, cruciate-retaining TKAs were performed, as part of an 8-site multicenter study. All procedures were performed with the use of an intraoperative sensor to ensure quantitative balance, as per previously reported literature. Of the 75-patient cohort, 50 patients were balanced with the MNPT; 20 patients were balanced with traditional transection. All patients were followed out to 1-year, and administered KSS, WOMAC, and satisfaction. Alignment and ROM was captured for all patients, pre-operatively and at the 1-year follow-up interval.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_7 | Pages 18 - 18
1 May 2016
Anderson J Campbell P Nelson S
Full Access

Avascular necrosis of the femoral head (AVN) is associated with collapse of the femoral head and arthritic degeneration of the joint. The combination of an implant inserted into the femoral head that provides mechanical support and bone grafting to promote bone formation may offer a possible joint-preserving solution1. Seventeen such procedures were performed between November 2012 and March 2014 during an IRB approved clinical trial. Thirteen out of 18 patients remained unrevised at a minimum of 12 months; the results of radiographic and histological analysis of four revisions are presented.

The investigational device (Figure 1) was developed as a joint preserving treatment for AVN with a clinical grade of IIC or less according to the ARCO grading system2.

The device consisted of a braided spherical Nitinol cage with a Titanium / Nitinol orientation feature. It was implanted using fluoroscopic navigation into a spherical cavity cut into the femoral head via an 11mm diameter access tunnel. Once deployed, the implant was filled with a lightly impacted mixture of autologous bone graft and bone marrow soaked Conduit TCP (DePuy CMW, Blackpool, UK). The implant's purpose was to provide mechanical support to the weakened subchondral surface while the bone graft mixture re-integrated with the host bone.

The retrieved femoral heads were trimmed to leave approximately 3mm of bone around the implant, dehydrated, embedded in methacrylate resin, sectioned and thinned into 50–70µm coronal slices for histological analysis. The following observations were made (Figure 2):

Case 1 (Female, age 70, ARCO IIB, revised after 2 days): The patient was revised for spontaneous sub-trochanteric fracture secondary to osteoporosis. Contact between the native bone and bone graft was observed. Marrow elements and repair tissue were visible within the pores in the graft (Figure 2a).

Case 2 (Male, age 67, ARCO IIIC, revised after 82 days): Two wires were broken but retained within the braided structure. A radiolucent gap caused by the presence of fibrous tissue between the graft mixture and native bone was evident suggesting that the implant was unable to prevent progression in this case.

Case 3 (Female, age 70, ARCO IIC, revised after 482 days): The cavity penetrated the subchondral surface; at revision the implant was found to have breached the articular cartilage. There was partial separation of the proximal osteonecrotic fragment and no evidence of graft revascularisation or remodelling within the implant.

Case 4 (Male, age 42, ARCO IIC, revised after 469 days): There was no indication of bone graft re-integration. Collapse of the necrotic bone and deformation of the implant was diagnosed from 1 year follow-up x-rays.

Conclusion

This treatment has preserved the joints of fourteen patients. Of the four revised, two patients had clinical grades or bone quality contra-indicated for the device and three had lesions occupying more than 30% of the femoral head: Improved criteria for patient selection may be required. The device is only partially load-bearing and incapable of stabilising fractures: The radiolucent band associated with fibrous tissue formation may be an early indication of failure.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_8 | Pages 19 - 19
1 May 2016
Halloran J Zadzilka J Colbrunn R Bonner T Anderson C Klika A Barsoum W
Full Access

Introduction

Improper soft-tissue balancing can result in postoperative complications after total knee arthroplasty (TKA) and may lead to early revision. A single-use tibial insert trial with embedded sensor technology (VERASENSE from OrthoSensor Inc., Dania Beach, FL) was designed to provide feedback to the surgeon intraoperatively, with the goal to achieve a “well-balanced” knee throughout the range of motion (Roche et al. 2014). The purpose of this study was to quantify the effects of common soft-tissue releases as they related to sensor measured joint reactions and kinematics.

Methods

Robotic testing was performed using four fresh-frozen cadaveric knee specimens implanted with appropriately sized instrumented trial implants (geometry based on a currently available TKA system). Sensor outputs included the locations and magnitudes of medial and lateral reaction forces. As a measure of tibiofemoral joint kinematics, medial and lateral reaction locations were resolved to femoral anterior-posterior displacement and internal-external tibial rotation (Fig 1.). Laxity style joint loading included discrete applications of ± 100 N A-P, ± 3 N/m I-E and ± 5 N/m varus-valgus (V-V) loads, each applied at 10, 45, and 90° of flexion. All tests included 20 N of compressive force. Laxity tests were performed before and after a specified series of soft-tissue releases, which included complete transection of the posterior cruciate ligament (PCL), superficial medial collateral ligament (sMCL), and the popliteus ligament (Table 1). Sensor outputs were recorded for each quasi-static test. Statistical results were quantified using regression formulas that related sensor outputs (reaction loads and kinematics) as a function of tissue release across all loading conditions. Significance was set for p-values ≤ 0.05.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_10 | Pages 1 - 1
1 May 2016
Elson L Roche M Wang K Anderson C
Full Access

Introduction

Aseptic loosening has been reported to be the most common, contemporary mode of total knee arthroplasty failure. It has been suggested that the etiology of revision due to loosening can be attributed, in part, to joint imbalance and the variability inherent in standard surgical techniques. Due to the high prevalence of revision, the purpose of this study was to quantify the change in kinetic loading of the knee joint before versus after the application of the final cement-component complex.

Methods

Ninety-two consecutive, cruciate-retaining TKAs were performed, between March 2014 and June 2014, by two collaborating surgeons. Two different knee systems were used, each with a different viscosity cement type (either medium viscosity or high viscosity). All knees were initially balanced using a microelectronic tibial insert, which provides real-time feedback of femoral contact points and joint kinetics. After the post-balance loads were captured, and the surgeon was satisfied with joint balance, the final components were cemented into place, and the sensor was re-inserted to capture any change in loading due to cementing technique.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_8 | Pages 18 - 18
1 May 2016
Halloran J Colbrunn R Anderson C
Full Access

INTRODUCTION

Understanding the relationship between knee specific tissue behavior and joint contact mechanics remains an area of focus. Seminal work from 1990's established the possibility to optimize tissue properties for recreation of laxity driven kinematics (Mommersteeg et al., 1996). Yet, the uniqueness and validity of such predictions could be strengthened, especially as they relate to joint contact conditions. Understanding this interplay has implications for the long term performance of joint replacements.

Development of instrumented knee implants, highlighted by a single use tibial insert trial with embedded sensor technology (VERASENSE, Orthosensor Inc.), may offer an avenue to establish the relationship between tissue state and joint mechanics. Utilization of related data also has the potential to confirm computational predictions, where both rigid body motions and associated reactions are explicitly accounted for. Hence, the goal of this work was to evaluate an approach for optimization of ligament properties using joint mechanics data from an instrumented implant during laxity style testing. Such a framework could be used to inform joint balancing techniques, improve long term implant performance, and alternatively, qualify factors that may lead to poor outcomes

METHODS

Experimentation was performed on a 52 year old male, left, cadaveric specimen. Joint arthroplasty was performed using standard practice by an experienced orthopedic surgeon. To mimic passive intraoperative loading, laxity loading at 10°, 45° and 90° flexion, which consisted of discrete application of anterior-posterior (± 100N), varus-valgus (± 5 Nm) and internal-external (± 3 Nm) loads at each angle, was performed using a simVITROTM robotic musculoskeletal simulator (Cleveland Clinic, Cleveland, OH). Experimental results included relative tibiofemoral kinematics and sensor measured metrics (Fig 1).

The finite element model was developed from specimen-specific MRIs and solved using Abaqus/Explicit. The model included the rigid bones, appropriately placed implants and relevant soft-tissue structures (Fig. 1). Ligament stiffness values were adopted from the literature and included a 6% strain toe region. Sets of nonlinear springs, defined using MR imaging, comprised each ligament/bundle. Optimization was performed, which minimized the root mean squared difference between VERASENSE measured tibiofemoral mechanics and the model predicted values. Ligament slack lengths were the control variables and the objective included each loading state and all contact metrics (θ, AFD, ML, and LL).


Bone & Joint Research
Vol. 5, Issue 2 | Pages 33 - 36
1 Feb 2016
Jenkins PJ Morton A Anderson G Van Der Meer RB Rymaszewski LA

Objectives

“Virtual fracture clinics” have been reported as a safe and effective alternative to the traditional fracture clinic. Robust protocols are used to identify cases that do not require further review, with the remainder triaged to the most appropriate subspecialist at the optimum time for review. The objective of this study was to perform a “top-down” analysis of the cost effectiveness of this virtual fracture clinic pathway.

Methods

National Health Service financial returns relating to our institution were examined for the time period 2009 to 2014 which spanned the service redesign.


Bone & Joint Research
Vol. 5, Issue 2 | Pages 26 - 32
1 Feb 2016
Wendling A Mar D Wischmeier N Anderson D McIff T

Objectives

The objective of this study was to determine if combining variations in mixing technique of antibiotic-impregnated polymethylmethacrylate (PMMA) cement with low frequency ultrasound (LFUS) improves antibiotic elution during the initial high phase (Phase I) and subsequent low phase (Phase II) while not diminishing mechanical strength.

Methods

Three batches of vancomycin-loaded PMMA were prepared with different mixing techniques: a standard technique; a delayed technique; and a control without antibiotic. Daily elution samples were analysed using flow injection analysis (FIA). Beginning in Phase II, samples from each mix group were selected randomly to undergo either five, 15, 45, or 0 minutes of LFUS treatment. Elution amounts between LFUS treatments were analysed. Following Phase II, compression testing was done to quantify strength. A-priorit-tests and univariate ANOVAs were used to compare elution and mechanical test results between the two mix groups and the control group.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_1 | Pages 16 - 16
1 Jan 2016
Anderson C Roche M Golladay G Elson L
Full Access

INTRODUCTION

Achieving balance in TKA is critical in assuring favorable outcomes. But, in order to achieve quantifiably balanced loading values, is it more advantageous to make bony corrections or release soft-tissue? The answer to this question will be paramount in evaluating the most appropriate surgical techniques for use with new dynamic technology, thereby maximizing favorable clinical outcomes. Therefore, the purpose of this investigation was to evaluate a possible quantitative loading threshold, using intraoperative sensors, which may dictate surgical correction of bone versus soft-tissue release.

METHODS

A retrospective analysis of 122 multicenter patients, in receipt of sensor-assisted primary TKA, was conducted. 40 lbs. was used as a threshold, above which bone was corrected; below which soft-tissue was corrected. All patients were categorized in to the following groups: Group A – candidates for bony correction, but received soft-tissue correction; Group B – candidates for soft-tissue/receiving soft-tissue; Group C – candidates for bony correction/receiving bony correction.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_3 | Pages 37 - 37
1 Jan 2016
Anderson C Gustke KA Roche M Golladay G Meere P Elson L
Full Access

INTRODUCTION

Patient-reported satisfaction is a critical measure in understanding the clinical success of total knee arthroplasty. Yet, satisfaction levels in TKA patients are generally lower than THA patients; and surgeon-patient agreeability regarding clinical success is typically in discordance. Thus, the purpose of this evaluation was to report on the one-year satisfaction data of a group of sensor-assisted TKA patients, and compare that data to the average satisfaction reported in literature, as measured by a meta-analysis.

METHODS

One hundred and thirty five patients received TKA utilizing intra-operative sensing technology to evaluate soft-tissue balance as part of a prospective multicenter study. Patients were classified by two groups: “balanced” and “unbalanced”. Quantitative “balance” was defined as a mediolateral intercompartmental loading difference of ≤ 15 pounds; all loading exceeding 15 pounds was classified as “unbalanced”. At the one-year follow-up visit, a 7-question patient satisfaction survey was administered. The answering schema of this survey was modeled using a modified five-point Likert scale, ranging from “True” to “False” (or “Very Satisfied” to “Very Dissatisfied,” where appropriate). A meta-analysis of literature was performed and studies selected for inclusion in this analysis were required to meet the following criteria: all patients were in receipt of a primary TKA; satisfaction data was collected post-operatively; and the proportion of patients who were “satisfied” to “very satisfied” was statistically described.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_3 | Pages 33 - 33
1 Jan 2016
Anderson C Gustke KA Roche M Golladay G Meere P Elson L
Full Access

INTRODUCTION

The cost associated with the TKA revision burden is projected to reach 13 billion dollars, annually. Complications reported by post-TKA patients include: pain (44%, multilocational), sensation of instability (21% reason for revision), and joint stiffness (17% reason for revision); problems that may be attributed to soft-tissue imbalance. One of the possible reasons for the substantial prevalence of such complications is the subjectivity associated with defining soft-tissue balance. A priority must be placed on developing new objective methods with which to avoid costly post-operative complications, including the integration of intraoperative sensing technology. The purpose of this evaluation was to report on the disparity between the patient-reported outcomes scores of quantitatively balanced versus unbalanced patients, at 1-year, using a group of 135 multicenter patients.

METHODS

135 prospective patients, from 8 U.S. sites, have had primary TKA performed with the use of intraoperative sensors. Patients were classified by two groups: “balanced” and “unbalanced”. Quantitative “balance” was defined as a mediolateral intercompartmental loading difference of ≤ 15 pounds; all loading exceeding 15 pounds was classified as “unbalanced”. For all patients, the following kinematic data was captured: varus/valgus stability, anteroposterior stability, flexion contracture (if any), extension lag (if any), anatomic alignment, and ROM. Also at each clinical follow-up visit, activity levels and two patient-reported outcomes measures were administered, including: the American Knee Society Score (KSS), and the Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC).


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_34 | Pages 505 - 505
1 Dec 2013
Elson L Gustke KA Golladay G Roche M Anderson C
Full Access

Introduction

During primary total knee arthroplasty, the surgeon may encounter excessive medial collateral ligament tension while addressing a varus knee. This may be due to medial ligament/capsular complex contractures, and/or, due to the creation of a 0 degree mechanical axis in a varus knee. This tension leads to increased loading in the medial compartment, which contributes to an unbalanced extension and flexion gap. If uncorrected, this imbalance can lead to unfavorable clinical outcomes, including: pain, accelerated polyethylene degradation, joint instability, and limited ROM. Currently, intercompartmental soft-tissue balance is obtained by a subjective surgeon's “feel”. However, this method of judging soft-tissue tension is both variable and unreliable. Most surgeons can detect gross instability, but judging ligament tension is difficult. The following technique describes the integration of intraoperative microelectronic tibial inserts to assess and modify ligament tension, utilizing real-time dynamic sensor feedback

Methods

500 TKAs were performed between September 2012 and April 2013, by three collaborating surgeons. All surgeons used the same implant system, compatible with an embedded microelectronic tibial insert with which to receive real-time feedback of femoral contact points and joint kinetics. Intraoperative kinematic data, displayed loading patterns consistent with identifiable intercompartmental imbalance through a full ROM. All mediolateral imbalance, secondary to an excessively tight medial compartment, was addressed with the technique described herein.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_34 | Pages 202 - 202
1 Dec 2013
Weiss J Henak CE Anderson AE Peters CL
Full Access

Introduction:

Most cases of hip osteoarthritis (OA) are believed to be caused by alterations in joint contact mechanics resulting from pathomorphologies such as acetabular dysplasia and acetabular retroversion. Over the past 13 years, our research group has focused on developing approaches for patient-specific modeling of cartilage and labrum in the human hip, and applying these approaches to study hip pathomorphology. The long term objective is to improve the understanding of the etiology of OA related to hip pathomorphology, and to improve diagnosis and treatment. The objectives of this presentation are to provide a summary of our subject-specific modeling approach, and to describe the results of our analysis of hips from three populations of subjects: normal, traditional dysplastic, and retroverted.

Methods:

A combined experimental and computational protocol was used to investigate contact mechanics in ten normal subjects (normal center edge angles (CEA), no history of hip pain), ten subjects with hip pain secondary to acetabular dysplasia (CEA less than 25°), and ten patients with a radiographic crossover sign, pain and clinical exams consistent with acetabular retroversion. CT arthrography was used to image cartilage and bone. Volumetric image data were segmented and discretized, and subject-specific finite element models were produced using validated methods [Fig. 1]. Boundary and loading conditions were obtained from instrumented implant and gait data. Contact mechanics were evaluated on the acetabular cartilage and labrum. Labrum contact area and peak contact stress were evaluated. Cartilage contact area, peak and average contact stress were evaluated in six anatomical regions in the acetabulum.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_34 | Pages 162 - 162
1 Dec 2013
Elson L Roche M Anderson C
Full Access

Introduction

Post-operative clinical outcomes of TKA are dependent on a multitude of surgical and patient-specific factors. Malrotation of the femoral and/or tibial component is associated with pain, accelerated wear of the tibial insert, joint instability, and unfavorable patellar tracking and dislocation. Using the transepicondylar axis to guide implantation of the femoral component is considered to be an accurate anatomical reference and is widely used. However, no gold standard currently exists with respect to ensuring optimal rotation of the tibial tray. Literature has suggested that implantation methods, which reference the tibial tubercle, reduce positioning outliers with more consistency than other anatomical landmarks. Therefore, the purpose of this evaluation is to use data collected from intraoperative sensors to assess the true rotational accuracy of using the mid-medial third of the tibial tubercle in 98 TKAs.

Methods

The data for this evaluation was retrieved from 98 consecutive patients who underwent primary TKA from the same highly experienced surgeon. Femoral component rotation was verified in every case via the use of the Whiteside line, referencing the transepicondylar axis, and confirming appropriate patellar tracking. Tibial tray rotation was initially established by location of the mid-medial third of the tibial tubercle. Rotational adjustments of the tibial tray were evaluated in real-time, as the surgeon corrected any tibiofemoral incongruency and tray malpositioning. The initial and final angles of tibial tray rotation were captured with intraoperative video feed, and recorded. A z-test of differences between pre- and post-rotational correction was performed to assess the statistical significance of malrotation present in this cohort.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_34 | Pages 44 - 44
1 Dec 2013
DeClaire J Vishwanathan K Ramaseshan K Wood M Anderson S
Full Access

Background:

A large percentage of the patients who present for unilateral TKA have bilateral disease. Performing simultaneous, bilateral TKA has been debated and currently there is no consensus on the risks and benefit of this approach. In addition, specific selection criteria have not been defined to more accurately identify which patients are potentially appropriate candidates for this approach.

Objectives:

The purpose of this study was to evaluate the clinical outcomes and peri-operative complications in simultaneous, bilateral TKA's using pre-operative patient selection criteria.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_34 | Pages 203 - 203
1 Dec 2013
Weiss J Anderson AE Peters CL Henak CE Ellis BJ Kapron AL Harris MD Abraham CL Erickson J
Full Access

This presentation will provide an overview of the interdisciplinary research program on hip pathomorphology at the University of Utah, including studies of dysplasia and femoracetabular impingement. The discussion will emphasize the implications of the research findings for hip preserving surgery


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_34 | Pages 508 - 508
1 Dec 2013
Elson L Gustke KA Golladay G Roche M Meere P Anderson C
Full Access

Introduction

Flexion instability of the knee accounts for, up to, 22% of reported revisions following TKA. It can present in the early post-operative phase or present— secondary to a rupture of the PCL— in the late post-operative phase. While most reports of instability occur in conjunction with cruciate retaining implants, instability in a posterior-stabilized knee is not uncommon. Due to the prevalence of revision due to instability, the purpose of constructing the following techniques is to utilize intraoperative sensors to quantify flexion gap stability.

Methods

500 posterior cruciate-retaining TKAs were performed between September 2012 and April 2013, by four collaborating surgeons. All surgeons used the same implant system, compatible with a microelectronic tibial insert with which to receive real-time feedback of femoral contact points and joint kinetics. Intraoperative kinematic data, as reported on-screen by the VERASENSE™ knee application, displayed similar loading patterns consistent with identifiable sagittal plane abnormalities. These abnormalities were classified as: “Balanced Flexion Gap,” “Flexion Instability” and “Tight Flexion Gap.” All abnormalities were addressed with the techniques described herein.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_30 | Pages 2 - 2
1 Aug 2013
Gupta S Maclean M Anderson J MacGregor S Meek R Grant M
Full Access

Infection rates following arthroplasty surgery are between 1–4%, with higher rates in revision surgery. The associated costs of treating infected arthroplasty cases are considerable, with significantly worse functional outcomes reported. New methods of infection prevention are required. HINS-light is a novel blue light inactivation technology which kills bacteria through a photodynamic process. The aim of this study was to investigate the efficacy of HINS-light for the inactivation of bacteria isolated from infected arthoplasty cases.

Specimens from hip and knee arthroplasty infections are routinely collected to identify causative organisms. This study tested a range of these isolates for sensitivity to HINS-light. During testing, bacterial suspensions were exposed to increasing doses of HINS-light of (123mW/cm2 irradiance). Non-light exposed control samples were also set-up. Bacterial samples were then plated onto agar plates and incubated at 37°C for 24 hours before enumeration.

Complete inactivation was achieved for all Gram positive and negative microorganisms

More than a 4-log reduction in Staphylococcus epidermidis and Staphylococcus aureus populations were achieved after exposure to HINS-light for doses of 48 and 55 J/cm2, respectively. Current investigations using Escherichia coli and Klebsiella pneumoniae show that gram-negative organisms are also susceptible, though higher doses are required.

This study has demonstrated that HINS-light successfully inactivated all clinical isolates from infected arthroplasty cases. As HINS-light utilises visible-light wavelengths it can be safely used in the presence of patients and staff. This unique feature could lead to possible applications such as use as an infection prevention tool during surgery and post-operative dressing changes.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_28 | Pages 112 - 112
1 Aug 2013
Kress K Anderson C
Full Access

Acetabular component positioning is highly correlated with total hip arthroplasty (THA) outcomes. Multiple reports however indicate that less than 50% of acetabular cups are placed within surgeon-desired ranges for abduction and anteversion angles when using conventional cup positioning techniques. Issues with improper placement include instability-dislocation, impingement and impact on range of motion, polyethylene wear, leg length discrepancy, and gait mechanics. Accuracy in placement of the acetabular component is complicated by the need to estimate cup impactor angles to create desired cup position. A low cost approach to THA using Image-based Ultrasonic Guidance (IUG) (Orthosensor, Sunrise, FL) coupled to existing surgical tools is presented. IUG utilises acoustic measurement techniques for achieving optimal component positioning and leg length. A precisely machined Hip Test Fixture (HTF) has been built to simulate the anatomical pelvis, acetabular cup, and femur to validate system accuracy.

The IUG was affixed to the HTF to demonstrate placement of the cup during THA. The HTF was loaded onto a 27-inch Graphic User Interface (GUI) providing three-dimensional CAD data of the HTF. Registration points included the Iliac Crest and 10 points around the acetabular cup. These points were mapped to the CAD data by the GUI. The HTF was set to 45° of abduction and 0° of version to begin testing. Abduction and version were measured over a +15° range in 1-degree increments while leg length and offset were measured over a +5mm range in 2mm increments. A high-resolution coordinate measurement machine (FaroArm EDGE) verified the accuracy and margin of error for inclination, version, leg length and offset at each increment.

The HTF provided a precise means for evaluating IUG system accuracy of simulated THA in a controlled environment. Acceptable margins of error were reported on the HTF: mean error for version was 0.36° (SD 0.02°; 0.25° to 0.38°); mean error for inclination was 1.04° (SD 0.52°; 0.48° to 1.66°); mean error for leg length and offset were respectively 0.36mm (SD 0.86mm; −0.65 to 1.55mm) and 0.41mm (SD 0.28; 0.05 to 0.80mm).

IUG provides a means for achieving acceptable precision and accuracy in component placement during THA as evaluated with the HTF. Further study is however necessary to correlate accuracy of IUG with clinical utility and short-term clinical outcomes.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_31 | Pages 54 - 54
1 Aug 2013
Gupta S Maclean M Anderson J MacGregor S Meek R Grant M
Full Access

Infection rates following arthroplasty surgery are between 1–4%, with higher rates in revision surgery. The associated costs of treating infected arthroplasty cases are considerable, with significantly worse functional outcomes reported. New methods of infection prevention are required. HINS-light is a novel blue light inactivation technology which kills bacteria through a photodynamic process. The aim of this study was to investigate the efficacy of HINS-light for the inactivation of bacteria isolated from infected arthroplasty cases.

Specimens from hip and knee arthroplasty infections are routinely collected to identify causative organisms. This study tested a range of these isolates for sensitivity to HINS-light. During testing, bacterial suspensions were exposed to increasing doses of HINS-light of (123 mW/cm2 irradiance). Non-light exposed control samples were also set-up. Bacterial samples were then plated onto agar plates and incubated at 37°C for 24 hours before enumeration.

Complete inactivation (greater than a 4-log reduction) was achieved for all of the clinical isolates from infected arthroplasty cases. The typical inactivation curve showed a slow initial reaction followed by a period of rapid inactivation. The doses of HINS-light exposure required ranged from 118–2214 J/cm2 respectively. Gram-positive bacteria were generally found to be more susceptible than Gram-negative.

This study has demonstrated that HINS-light successfully inactivated all clinical isolates from infected arthroplasty cases. As HINS-light utilises visible-light wavelengths it can be safely used in the presence of patients and staff. This unique feature could lead to possible applications such as use as an infection prevention tool during surgery and post-operative dressing changes.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_15 | Pages 313 - 313
1 Mar 2013
Anderson C Roche M
Full Access

Introduction

Optimized tibial tray rotation during a total knee replacement (TKR) is critical for tibiofemoral congruency through full range of motion, as it affects soft tissue tension, stability and patellar tracking. Surgeons commonly reference the tibial tubercle, or the “floating tibial tray,” while testing the knee in flexion and extension. Utilization of embedded sensors may enable the surgeon to more accurately assess tibiofemoral contact points during surgery.

Methods

The malrotation of the tibiofemoral congruency when utilizing the mid to medial 1/3 of the tibial tubercle for tibial rotation was evaluated in 50 posterior cruciate ligament-retaining TKRs performed by an experienced, high-volume surgeon. Sensors were embedded in the tibial trials; the rotation of the tibial tray was defined, and the femoral contact points in each compartment were captured. The surgical procedure was performed to size and then appropriately rotate the tibial tray. The anterior medial tray was pinned to control anterior-posterior and medio-lateral displacement, and allow internal and external rotation of the tray. With the capsule closed and patella reduced, the knee was reduced with trial implants. The femoral contact points and medial-lateral soft tissue tension were documented. Patellar tracking and changes in soft tissue tension were also documented.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_5 | Pages 9 - 9
1 Feb 2013
Gupta S Maclean M Anderson J MacGregor S Meek R Grant M
Full Access

Infection rates following arthroplasty surgery are between 1–4%, with higher rates in revision surgery. The associated costs of treating infected arthroplasty cases are considerable, with significantly worse functional outcomes reported. New methods of infection prevention are required. HINS-light is a novel blue light inactivation technology which kills bacteria through a photodynamic process. The aim of this study was to investigate the efficacy of HINS-light for the inactivation of bacteria isolated from infected arthoplasty cases.

Specimens from hip and knee arthroplasty infections are routinely collected to identify causative organisms. This study tested a range of these isolates for sensitivity to HINS-light. During testing, bacterial suspensions were exposed to increasing doses of HINS-light of (123mW/cm2 irradiance). Non-light exposed control samples were also set-up. Bacterial samples were then plated onto agar plates and incubated at 37°C for 24 hours before enumeration.

Complete inactivation was achieved for all Gram positive and negative microorganisms More than a 4-log reduction in Staphylococcus epidermidis and Staphylococcus aureus populations were achieved after exposure to HINS-light for doses of 48 and 55 J/cm2, respectively. Current investigations using Escherichia coli and Klebsiella pneumoniae show that gram-negative organisms are also susceptible, though higher doses are required.

This study has demonstrated that HINS-light successfully inactivated all clinical isolates from infected arthroplasty cases. As HINS-light utilises visible-light wavelengths it can be safely used in the presence of patients and staff. This unique feature could lead to possible applications such as use as an infection prevention tool during surgery and post-operative dressing changes.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXIX | Pages 161 - 161
1 Sep 2012
Gupta S MacLean M Anderson J MacGregor S Meek R Grant M
Full Access

Introduction

Infection rates following arthroplasty surgery are reported between 1–4%, with considerably higher rates in revision surgery. The associated costs of treating infected arthroplasty cases are over 4 times the cost of primary arthroplasties, with significantly worse functional and satisfaction outcomes. In addition, multiple antibiotic resistant bacteria are developing, so to reduce the infection rates and costs associated with arthroplasty surgery, new preventative methods are required. HINS-light is a novel blue light inactivation technology which kills bacteria through a photodynamic process, and is proven to have bactericidal activity against a wide range of species. The aim of this study was to investigate the efficacy of HINS-light for the inactivation of bacteria isolated from infected arthoplasty cases.

Methods

Specimens from hip and knee arthroplasty infections are routinely collected in order to identify possible causative organisms and susceptibility patterns. This study tested a range of these isolates for sensitivity to HINS-light. During testing, bacterial suspensions were exposed to increasing doses of HINS-light of (66mW/cm2 irradiance). Non-light exposed control samples were also set-up. Bacterial samples were then plated onto agar plates and incubated at 37°C for 24 hours before enumeration.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXII | Pages 4 - 4
1 Jul 2012
Boyd M Anderson T Middleton S Brinsden M
Full Access

Skills simulation is increasingly used as a training tool in postgraduate surgical training. Trainee's perception of the value of this experience has not previously been investigated. The aim of this investigation was to investigate the value of surgical simulation training delivered by an arthroscopy skills course.

We constructed a subject-specific, self-assessment questionnaire based around the ISCP Peer Assessment Tool. The questionnaire was administered to candidates before and after attending the Plymouth Arthroscopy Skills Course. Participant demographic data was recorded. Questionnaire data was interrogated to give an overview of the course, as well as the benefit of site-specific skills stations. Statistical analysis showed the data to be normally distributed. The paired T-test was used to compare mean values.

Twelve surgical trainees attended the course – CT2 trainees (n=4); ST3 trainees (n=7); ST4 trainee (n=1). 11 candidates completed both administered questionnaires giving a 92% response rate. The global mean score at the beginning of the course was 2.39. The global mean score at the end of the course was 3.90. The mean improvement was 1.51 (p<0.01; 95% CI= 0.96-2.07). Skill station specific scores all showed improvement with the greatest effect in wrist arthroscopy. CT trainees had a lower mean score compared to ST trainees. Both groups completed the course with similar mean scores.

This study shows that arthroscopy simulation improves trainee-reported ratings of surgical skill. It also shows that less experienced candidates derived the greatest benefit from the training. Further research is required to compare self-assessed performance against objective benchmarks using validated assessment tools.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXII | Pages 20 - 20
1 Jul 2012
Middleton S Guyver P Boyd M Anderson T Brinsden M
Full Access

Military patients have high functional requirements of the upper limb and may have lower pre-operative PROM scores than civilian patients i.e. their function is high when benchmarked, but still insufficient to perform their military role thereby mandating surgery. Our aim was to compare the pre-operative Oxford Shoulder Instability Scores in military and civilian patients undergoing shoulder stabilisation surgery.

We undertook a prospective, blinded cohort-controlled study (OCEBM Level 3b). The null hypothesis was that there was no difference in the Oxford Shoulder Instability Scores between military and civilian groups. A power calculation showed that 40 patients were required in each group to give 95% power with 5% significance. A clinical database (iParrot, ByResults Ltd., Oxford, UK) was interrogated for consecutive patients undergoing shoulder stabilisation surgery at a single centre. The senior author - blinded to the outcome score - matched patients according to age, gender and diagnosis. Statistical analysis showed the data to be normally distributed so a paired samples t-test was used to compare the two groups. 110 patients were required to provide a matched cohort of 80 patients.

There were 70 males and 10 females. Age at the time of surgery was 16-19yrs (n=6); 20-24yrs (n=28); 25-29 (n=16); 30-34(n=12); 35-49(n=12); 40-44(n=6). 72 patients (90%) had polar group one and 8 patients (10%) had polar group two instability. The mean Oxford Shoulder Instability Score in the civilian group was 17 and the in military group was 18. There was no statistical difference between the two groups (p=0.395).

This study supports the use the Oxford Shoulder Instability Score to assess military patients with shoulder instability.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXVIII | Pages 16 - 16
1 Jun 2012
Russell D Pillai A Anderson K Kumar C
Full Access

Regional anaesthetic for foot surgery has been discussed as a method of post operative analgesia. Ankle block as the sole anaesthetic for foot surgery has not been extensively reviewed in the literature. We aimed to describe our experience of forefoot surgery under ankle block.

Sixty-six consecutive forefoot procedures (59 patients) were carried out under ankle block. Patients were contacted post operatively and completed a standardised questionnaire including an incremental pain assessment ranging from 0-10 (0 no pain, 10 severe pain).

Forty nine female and 10 male patients (age range 20-85y) were included. Procedures included 33 first metatarsal osteotomies, 15 cheilectomies, 3 first MTP joint replacements, 5 fusions, 4 excision of neuroma and 6 other procedures. 22 patients (33% of cases) reported discomfort during the block procedure (average pain score 1.5). 6 patients reported pain during their operation(s), average score 0.26. Average pain scores at 6, 12, 24 and 48 hours following surgery were 2.0, 3.2, 2.7 and 2.1 respectively. All patients were discharged home and walking on the same day. There were no readmissions. Each patient confirmed they would have surgery under regional block rather than general anaesthesia and would recommend this technique to family and friends.

There are many advantages in being able to perform these relatively small procedures under regional anaesthesia. The anaesthesia obtained permits the majority of forefoot procedures and provides lasting post-operative analgesia. Combined with intra-operative sedation, use of ankle tourniquet and same day discharge; it has very high patient acceptance and satisfaction.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXII | Pages 34 - 34
1 May 2012
Russell D Pillai A Anderson K Kumar C
Full Access

Regional anaesthetic for foot surgery has been discussed as a method of post operative analgesia. Ankle block as the sole anaesthetic for foot surgery has not been extensively reviewed in the literature.

Aim

To describe our experience of forefoot surgery under ankle block.

Methods

71 consecutive forefoot procedures (65 patients) were carried out under ankle block. A mixture of 10ml 2% Lidocaine with 10ml 0.5 % Bupivacine was administered to the superficial peroneal, deep peroneal, sural and saphenous nerves. Ankle tourniquet was employed in all procedures. Patients were contacted post operatively and completed a standardised questionnaire including an incremented pain assessment ranging from 0-10 (0 no pain, 10 severe pain).


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XI | Pages 26 - 26
1 Apr 2012
Russell D Pillai A Kumar C Anderson K
Full Access

Regional anaesthetic for foot surgery has been discussed as a method of post operative analgesia. Ankle block as the sole anaesthetic for foot surgery has not been extensively reviewed in the literature.

We aimed to describe our experience of forefoot surgery under ankle block alone. 21 consecutive forefoot procedures (18 patients) were carried out under ankle block. The blocks were performed by the senior authors. A mixture of 10ml 2% Lidocaine with 10ml 0.5 % Bupivacaine was administered to the superficial peroneal, deep peroneal, sural and saphenous nerves. Ankle tourniquet was employed in all procedures. The patients were contacted post operatively and completed a standardised questionnaire including an incremented pain assessment ranging from 0-10 (0 no pain, 10 severe pain). 17 female and 1 male patients were contacted (age range 33-67y). Procedures included 13 first metatarsal osteotomies, 3 cheilectomies, 2 first MTP joint replacements, and 5 fusions. 14 patients requested a short acting sedative (midazolam). 5 patients (27 %) reported some discomfort during the block procedure (average pain score 1.2). No patients reported any pain during their operation(s). 4 patients (22%) required supplementation of the block. Average pain score at 6, 12, 24 and 48 hours following surgery were 0.66, 2.9, 2.4 and 1.3 respectively. All patients were discharged home and walking on the same day. None complained of nausea or required parenteral analgesia; there were no readmissions. Each patient confirmed they would have surgery under local block rather than general anaesthesia and would recommend this technique to family and friends.

Forefoot surgery under ankle block alone is safe and effective. Anaesthesia obtained permits the majority of forefoot procedures and provides lasting post-operative analgesia. Combined with intraoperative sedation, use of ankle tourniquet and same day discharge, it has very high patient acceptance and satisfaction.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_III | Pages 149 - 149
1 Feb 2012
Anderson A Smyth E Hamer A
Full Access

To assess whether prosthetic femoral stem centralisers have a detrimental effect on the macroporosity of the cement mantle, and if so, whether this is independent of their design and the rate of implantation, 30 identically cast moulded prosthetic femora were divided into 3 groups. Group 1: no centraliser (control), Group 2: centraliser A and Group 3: centraliser B. Using third generation cementation techniques and pressure monitoring, Charnley C-stems +/− the appropriate centraliser were implanted to a constant depth. Half in each group were implanted as rapidly as possible and the other half over 90 seconds. The stems were removed and the cement mantle then underwent a preliminary arthroscopic examination prior to being sectioned transversely at 3 constant levels. Each level was then photographed and digitally enlarged to a known scale to allow examination and determination of any cement voids (macropores) surface area.

There were no significant pressure fluctuations between the groups. Preliminary arthroscopic examination revealed that cement voids appeared more common when a centraliser was used. This difference was confirmed (p=0.002) following sectioning of the specimens, with cement voids found in 85% of femora when a centraliser was used and only 20% in the control group. Centraliser B performed worst with cement voids of a larger volume and more frequent occurrence (p=0.002). The macroporosity of the cement mantle was independent of the rate of implantation (p=0.39).

The use of femoral stem centralisers is helpful in preventing malposition of the implant but results in increased macroporosity of the cement mantle. This may have implications regarding the longevity of an implant in terms of early loosening and therefore their design and use must always be carefully considered.


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_IV | Pages 419 - 419
1 Nov 2011
Heuer D Williams M Moss R Butcher K Anderson M Milner R Alley C Gilmour L Scott M
Full Access

This study evaluated the biologic fixation of two different titanium porous coatings: a clinically successful sintered spherical bead coating [1] and a new sintered asymmetric particle coating (STIKTITE™, Smith & Nephew). The spherical bead coating has a porosity of about 50% and an average pore size of about 220 μm, whereas the STIKTITE coating has greater porosity (about 62%) and slightly smaller average pore size (about 200 μm). Biologic fixation was assessed using a load-bearing ovine model in which coated semi-circular disc implants were inserted into a defect created in the cancellous bone parallel to and approximately 3 mm below the medial tibial plateau [2] similar to the method reported by Ignatius [3]. The implants were slightly thicker than the defect created, producing a 0.2-mm overall pressfit. Initial implant stability was assessed using mechanical push-out (n = 3) immediately after implantation into cadaveric ovine bone. Quantitative mechanical push-out testing and qualitative histology (n = 9 and n = 2, respectively, per group per time point) was performed after six and 26 weeks in vivo.

The time-zero average peak push-out load (±S.D.) of the STIKTITE group (95±3 N) was found to be significantly greater (p < 0.02) than that of the spherical bead group (36±5 N). By six weeks in vivo, the average peak push-out load for the STIKTITE group was up to 1001±362 N, and that for the spherical bead group was up to 985±425 N, both representing a significant increase compared to their time-zero results (p < 0.0005). From six to twenty-six weeks in vivo, there was again a significant increase in the peak push-out load irrespective of group (p < 0.0005), with the average peak push-out loads up to 1620±406 N and 1444±446 N for the STIK-TITE and spherical bead groups, respectively. Histology revealed bone ingrowth in both groups that confirmed the findings of the mechanical push-out testing. While the STIKTITE group showed a trend toward greater biologic fixation, overall there was insufficient evidence to support differences between the two groups (p = 0.47) irrespective of the amount of time in vivo.

The results of this study confirm the ability of the STIK-TITE coating to achieve superior initial stability. This improved initial stability reduces the reliance on adjunct fixation (such as screws) or large amounts of press-fit to prevent micromotion and create an environment suitable for long-term bone ingrowth. The results also suggest that the STIKTITE coating had a tendency to initiate and maintain bone ingrowth under load-bearing conditions to a level greater than that of a clinically successful sintered bead coating. Because loading of the implant can cause micromotion at the bone/implant interface, models like the one used in this study likely provide a more challenging and realistic representation of anticipated clinical conditions than models with minimal implant loading.


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_III | Pages 381 - 381
1 Jul 2011
Munro J Shim V Anderson I Pitto R
Full Access

Aseptic loosening is the leading cause for revision in total hip arthroplasty. Retro-acetabular lysis is often a silent process until severe bone loss causes catastrophic failure. This presents a technically difficult problem for the surgeon and a poorer result for the patient compared to primary arthroplasty. While the major cause of osteolysis is reaction to polyethylene particles, there is little data on the initiation and progression of such lesions. Further, alterations in the mechanical environment caused by such pathology is unclear. We present our use of 3D, finite element (FE) models of retro-acetabular pathology to investigate the biomechanical effects of osteolysis in total hip arthroplasty. Axial CT scan slices from a patient with cystic osteolysis were selected. Areas of cortical bone, cancellous bone, the cup and the cyst are accurately identified. The axial images are matched to a predetermined grid and used to build a complex finte element model. In this way complex anatomy can be built into the FE model and used to map cystic lesions. Force is then applied to the acetabulum.

Initial analysis shows similar stress transmission in cystic disease compared to the post operative pelvis. Pelvic bone still behaves as a sandwich construct with transmission from the acetabulum to the SI joints, pubic symphysis and medial wall. In the setting of pelvic medial wall deficiency, stress transmission is altered with areas of low stress around the defect.

The FE models containing pathology can be compared to models with generic bone density values immediately after total hip arthroplasty. The presence of a cyst in cancellous bone with intact cortical bone, demonstrates strain patterns similar to the post operative pelvis. Once cortical bone loss occurs strain patterns begin to change. This may mark a critical point in osteolytic progression. We present a developing new tool to be used in the assessment of a patient population with retroacetabular cystic disease.


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_III | Pages 381 - 381
1 Jul 2011
Segar A Malak S Anderson I Pitto R
Full Access

Correct positioning of the femoral component in resurfacing hip arthroplasty (RHA) is an important factor in successful long-term patient outcomes. Computer-assisted navigation (CAS) shows potential to improve implant positioning and possibly prolong survivorship in total hip and knee arthroplasty. The purposes of CAS systems in resurfacing the femoral head are to insert the femoral head and neck guide wire with greater accuracy and to help in sizing the femoral component, thus reducing the risk of notching of the head and neck junction. Several recent studies reported satisfactory precision and accuracy of CAS in RHA. However, there is little evidence that computer navigation is useful in the presence of anatomical deformities of the proximal femur, which is frequently observed in young patients with secondary degenerative joint disease.

The purpose of this in-vitro study was to determine the accuracy of an image-free resurfacing hip arthroplasty navigation system in the presence of two femoral deformities: pistol grip deformity of the head and femoral neck junction and slipped upper femoral epiphysis deformity. An artificial phantom leg with a simulated hip and knee joint was constructed from machined aluminum. Implant-shaft angles for the guide wire of the femoral component reamer were calculated, in frontal and lateral planes, with both a computer navigation system and an electronic caliper combined with micro-CT.

With normal anatomy we found close agreement between the CAS system and our measurement system. However, there was a consistent disagreement in both the frontal and lateral planes for the pistol grip deformity. Close agreement was found only on the frontal plane angle calculation in the presence of the slipped upper femoral epiphysis deformity, but calculation of the femoral head size was inaccurate.

This is the first study designed to assess the accuracy of a femoral navigation system for resurfacing hip arthroplasty in the presence of severe anatomical deformity of the proximal femur. Our data suggests CAS technology should not be used to expand the range of utilisation of resurfacing surgery, but rather to improve the surgical outcome in those with suitable anatomy.


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_III | Pages 262 - 262
1 Jul 2011
Woodhouse LJ Petruccelli D Wright J Elliott W Toffolo N Patton S Samanta S Sardo A MacMillan D Johnson G Anderson C Evans W
Full Access

Purpose: Reducing wait times for total hip (THA) or knee (TKA) joint arthroplasty is a Canadian health care priority. Models that maximise the capacity of advanced practice clinicians (nurses, physical therapists, sports medicine specialists) have been established to streamline care. Hospitals across the Hamilton Niagara Haldimand Brant Local Health Integration Network in Ontario collaborated to establish a Regional Joint Assessment Centre (RJAC). This study was designed to profile patients deemed suitable for surgical review, and to examine wait times for THA or TKA in RJAC patients compared to those referred directly to an orthopaedic surgeon’s office.

Method: Patients referred to the RJAC between July 2007 and August 2008 with knee or hip OA were included. Self-reported function was evaluated using the Oxford Hip and Knee Score that is scored out of 60 (higher scores reflect greater disability). Time to surgery was measured as the number of days from initial review to surgery. Group one consisted of patients that were referred to the RJAC while group two was comprised of patients who were referred directly to a surgeon’s office. Patient characteristics were examined using univariate analyses. Independent t-tests were used to examine between group differences.

Results: One hundred thirty-six patients (mean±sd: 68±2 years, body mass index 31±6 kg/m2, 83 females) with 150 hip and/or knee joint problems were reviewed in the RJAC. Of those, only 33% (45/136 patients) were deemed suitable for surgical review. Self-reported function (Oxford Scores) in the group requiring surgical review was significantly worse (40±7, p=0.03) than in those patients deemed unsuitable for surgical review (37±9). The RJAC group waited on average 130 days for THA and 129 days for TKA (below the provincial target of 182 days) while those referred directly to the surgeons’ offices waited significantly longer (194 days for THA and 206 days for TKA, p< 0.001).

Conclusion: Patients with hip and knee OA who require surgical review have worse self-reported function than those triaged to conservative care. Wait times for THA or TKA were significantly shorter for patients referred to the RJAC under the new model of care than for those referred directly to an orthopaedic surgeon’s office.


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_III | Pages 460 - 460
1 Jul 2010
Oberlin O Rey A La T Bisogno G Koscielniak E Stevens M Meyer W Carli M Anderson J
Full Access

Objective: To determine patient characteristics and outcomes for extremity rhabdomyosarcoma (RMS) utilizing an international cohort of prospectively treated patients.

Methods: Data were collected from 566 patients (1984 through 2003) treated on cooperative protocols : US IRS III, IV Pilot, IV studies – SIOP 84, 89, 95 studies – Italian ICG 79, 88, 96 studies – German CWS81, 86, 91, 96 studies.

Results: 29 % of the patients were < 3 year old, 36 % were 3 to 10 year old and 35 % > 10 year old. 350 (63%) patients had alveolar RMS and 116 (22%) had regional nodes.

The overall survival and EFS were 65% and 51% at 5 years respectively and 59% and 48% at 10 years respectively.

By univariate analysis, EFS was influenced by age below 3 years but not by age over 10 years (EFS were 61%, 49% and 46% for patients below 3 years, from 3 to 10 and 10 years or more respectively). It was also influenced by tumor invasiveness, tumor size, lymph node involvement, histology, completeness of surgery at diagnosis and cooperative groups. In multivariate analysis of EFS, size, lymph nodes, quality of surgery, cooperative groups had independent impact. Age and histology had no more impact.

OS (univariate analysis) was influenced by age below 3 years but not by age over 10 years (OS were 77%, 61% and 58% for patients below 3 years, from 3 to 10 and 10 years or more respectively). In multivariate analysis, age, lymph nodes, tumour invasiveness, quality of surgery at diagnosis had independent impact. Histology, tumour size and cooperative groups had no more impact.

Conclusion: This analysis shows that significant cut-point for age is 3 years, that histology per se has no impact on OS and EFS. It also underscores the impact of initial surgery on outcome.


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_II | Pages 328 - 328
1 May 2010
Sidhom S Al-Lami M Sturdee S Anderson A Muthukumar N Hughes V Bennett C London N
Full Access

Aim: To assess the safety and efficacy of a mini-incision surgical (MIS) approach to knee arthroplasty (TKA) compared to a traditional standard approach.

Background: TKA through less invasive approaches have become increasingly popular in recent years. These range from smaller skin incisions to the ‘quadriceps-sparing’ procedures. Claims of improved recovery time and other clinical/economic advantages have been tempered by concerns about the safety of such procedures. This study was designed to evaluate any potential advantages of a specific approach (MIS) whilst studying peri-operative, radiological and outcome data to examine procedural safety.

Patients and Methods: 80 patients undergoing TKA were randomised to a standard or MIS (mini-midvastus) approach. The latter involved patella subluxation, rather than eversion. The operative, anaesthetic and post-operative treatments were standardised including rehabilitation protocols. Strict discharge criteria were established and independently verified and patients were discharged directly to their homes capable of independent care. Specifically the study evaluated patient demographics, operative time, blood loss and hospital stay. Outcome data including Knee Society Scores, Oxford Knee Scores and SF36 were recorded regularly in the early recovery period and up to 1 year post-operatively. Independent radiological review of implant positioning and alignment was obtained.

Results: There were no significant differences in operative time, blood loss, or other intra-operative data. Accelerated discharge was achieved in both groups (compared to historic data), however the length of stay (LOS) was significantly shorter in the MIS patients (mean – 3.5 days compared with 4.4 days in the standard patients). There was no statistical difference in clinical outcome analyses between the groups.

Discussion: Less invasive approaches to TKA have been reported over recent years but most studies have been anecdotal comparing patient recovery with historic controls which potentially can exaggerate clinical and economic benefits. Concerns have also been raised regarding the safety of these modified procedures. This study demonstrates a reduction in hospital stay and recovery in all patients as a result of accelerated rehabilitation. The MIS patients benefited from an additional significant reduction length of stay compared to controls with no evidence of compromise in terms of safety or efficacy.

Conclusions: This study has demonstrated the safety of the MIS mini-midvastus approach and a clear reduction in hospital length of stay. MIS surgery can offer substantial clinical and economic benefits but procedures must be closely evaluated to ensure equivalent or enhanced outcomes are achieved.


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_I | Pages 26 - 26
1 Mar 2010
Tornetta P Siegel J Burke P Kaseje N Agarwal S Soto J Anderson S
Full Access

Purpose: In patients with pelvic trauma, the need to quickly and accurately rule out sources of bleeding is paramount. We sought to determine the predictive value of CT angiography in determining the need for therapeutic angiography and to ascertain if definable arterial bleeding correlated with anatomic injury.

Method: Over a 2 year period 58 patients with a high-energy mechanism and pelvic injury underwent pelvic CT angiography as part of their initial trauma CT scan. This was performed as a 25 second delayed scan (after contrast introduction) using a GE light speed VCT64 scanner. The decision to proceed to therapeutic angiography was made on clinical grounds and was later compared with the CT angiographic findings. The anatomic location of bleeding on CT angio and interventional angio were compared.

Results: There were 36 male and 22 female patients, aged 43 (17 – 86), with average ISS of 18.6. The 18 (31%) patients with positive extravasation on CT angiography had higher initial blood requirements compared to those without extravasation. Two of the CT(+) group died prior to therapeutic angiography being performed. 11 of the remaining 16 had interventional angiography; 8 had (+) findings, including 7 major vessels coiled and 1 cutoff vessel observed. 1 patient of 40 with negative CT angiogram met clinical criteria had an interventional angiography; no arterial bleeding was discovered. The negative predictive value of CT angiography for pelvic arterial bleeding requiring therapeutic angiography was 100%; the positive predictive value of angiographically treatable bleeding was 70% (counting the two early deaths). The vessel location on CT angio and therapeutic angio was consistent in all cases. The CT angio (+) group had a higher percentage of unstable pelvic injuries (67% vs. 40%).

Conclusion: In this pilot study, CT angiography added to the initial trauma scan in patients with pelvic trauma demonstrated a 100% NPV for arterial bleeding that required therapeutic angiography on clinical grounds. Positive findings correlated well with the anatomic location of pelvic injury and had a 70% PPV for angio-graphically treatable bleeding. Further study of this technique is warranted.


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_I | Pages 202 - 202
1 Mar 2010
Anderson I Shim V Pitto R Malcolm D Mithraratne K Hunter P
Full Access

Patient- specific orthopaedic models are currently used in computer navigation. They provide realistic 3-D geometries for assessment of device placement (e.g. tibial trays, hip implants). Models are generated at time of operation by the surgeon. But patient-specific models have other uses. We envisage a future in which realistic 3-D patient models are routinely used for predicting the outcome of surgical procedures and new devices and for general patient health monitoring.

We are currently developing accurate 3-D models directly from CT scan post-operation. They are being used in investigations of the progress of bone remodeling. Such work can provide valuable feedback on the outcome of new procedures and how bone remodels under load. Such models would eventually include other tissue such as muscles and skin.

But there are a number of research and development challenges associated with the creation of patient-specific models. They include

minimal use of radiation for data collection;

need for an automated method of generating patient specific models as clinicians (not engineers) should be able to create computer models easily and quickly;

need for improvements in computational efficiency. An ultimate goal would be to run simulations on computer hardware that is available to the clinician;

How to deal with missing data. We need techniques for supplementing patient data with data from a “model library”;

Research to provide techniques for dealing with multiple organs (muscles, skin and bone altogether).

We are working to meet these challenges. They include the use of generic data to supplement patient data, efficient ways of morphing models to fit the patient, and multi-scale modeling strategies. Work in progress at the Auckland Bio-engineering Institute will be presented in this talk.


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_I | Pages 35 - 35
1 Mar 2010
Anderson SL Taillon MR Ernst M
Full Access

Purpose: 2 orthopaedic surgeons identified 18 patients who developed glenohumeral chondrolysis following arthroscopic shoulder surgery. The index surgery for all 18 patients occurred over an 18 month period. We sought to find any common factors among the 18 cases.

Method: A retrospective chart review of all 18 patients was performed. We gathered information on patient demographics, type of surgical procedure, nature of shoulder instability, post-operative complications such as infection, the use of radiofrequency energy, the type/number of suture anchors, the use of an IAPPC and the type of local anaesthetic used. We compared pre-operative radiographs and MRI scans to the intra-operative findings from the operative report to confirm that no chondrolysis was present pre-operatively. We examined post-operative radiographs and MRI scans to document the extent of chondrolysis

Results: Of the 18 patients who developed chondrolysis, we had 15 males and 3 females with an average age of 23 years (range 16–39). 17 patients had shoulder instability due to a definitive traumatic event while 1 patient had an atraumatic etiology. No radiofrequency energy was used in any of the cases. No post-operative infections were diagnosed and many had work-ups for infection which included ESR, CRP, bone & gallium/WBC scans. All patients had labral stabilization procedures, 15 anterior (Bankart), 1 posterior, and 2 combinations. All patients received suture anchors, 13 patients had 2 anchors and 5 had 3 anchors. 2 different manufacturer’s suture anchors were used, 10 patients received Smith & Nephew anchors while 8 patients received Linvatec anchors. 10 patients received bioabsorbable anchors and 8 patients received metal anchors. All patients received an IAPPC loaded with 0.5% bupivacaine with epinephrine for post-operative pain control. 15 of the IAPPC’s were considered large with an infusion rate of 5 mL/hr and a fill volume of 275 mL’s. 3 IAPPC’s were considered small with an infusion rate of 2 mL/hr and a fill volume of 100 mL’s.

Conclusion: We suspect a continuous intra-articular infusion of bupivacaine with epinephrine may have contributed to the development of chondrolysis. We caution against the use of IAPPC’s until their safety has been proven.


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_I | Pages 19 - 20
1 Mar 2010
Jones CB Sietsema DL Henning JA Anderson JG Bohay DR
Full Access

Purpose: To evaluate the functional outcome of operatively treated Lisfranc injuries.

Method: Over a 7-year interval from 1998 to 2005, 184 skeletally mature patients were identified retrospectively with operatively treated Lisfranc injuries. 85 patients had prospectively measured SMFA functional outcomes and satisfaction surveys. The gender was 37 males and 48 females. Mean age was 39 years (range 17–93).

Results: The mechanism was fall (31), MVA (24), crush (15), equestrian (5), or twisting (10). Patients were operatively treated with open reduction internal fixation (ORIF, 53) or primary arthrodesis (PA, 32). The SMFA reliability for this patient sample was 0.892. The function and bother outcomes were 19.4 and 15.8, respectively. The function (21.5 vs. 16.0, p=.11) and bother (17.5 vs. 13.0, p=.25) outcomes were not significantly different for ORIF vs. PA, respectively. In the ORIF group, HW removal (40 of 53) performed better than HW retention (13 of 53) with outcome bother but not function measures of (14.7 vs. 26.1, p< 0.05).

Conclusion: If performed well, either ORIF or PA technique function well. Patients are more satisfied with the results and appearance of PA over ORIF. HW removal compared to HW retention positively affect bother not function measures. Secondary surgeries negatively affect both bother and function measures. Patients with pain, associated foot or polytrauma injuries function worse.


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_I | Pages 228 - 228
1 Mar 2010
Singh A Anderson G
Full Access

Intramedullary nailing is acknowledged as a safe and effective mode of treatment for many tibial fractures. Implant removal is frequently indicated either as an elective procedure following union or because of problems such as infection or delayed fracture union. It is therefore essential that intramedullary rod removal should be reasonably straightforward and atraumatic.

We describe three cases in which bony growth into the implant has made rod removal either difficult or impossible. We include photographs of two removed implants with clearly visible areas of osseo-integration with bony growth into the cannulation through the interlocking holes as well as radiographs demonstrating the same phenomenon.

The average time between insertion and removal was 16 months. In all cases an end cap had been used such that insertion of the extraction device was straightforward but for two patients nail removal was extremely difficult due to bone ingrowth and in the third patient the nail had to be left in-situ. All three implants were made of titanium and the patients were all active young males. The authors have never encountered this problem with steel rods and speculate that the osteointegrative property of titanium is the major causative factor.

We suggest that unremoved intramedullary rods represent a major risk in fracture management and that close monitoring of these implants should be undertaken.


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_I | Pages 166 - 166
1 Mar 2010
Clarke I Lazennec Y Cattonne Y Kubo K Anderson I McPherson E Donaldson T
Full Access

FDA approval of metal-on-metal (MOM: 28, 32mm) bearings has provided 10 years of clinical experiences in USA. However there has been no detailed mapping of wear phenomena in retrieval cases. We present an analysis of 28 cases, MOM retrievals with 1 to 10 years follow-up, radiographic reviews and metal ion studies. Ball diameters ranged from 28mm to 42mm. Two balls were the early design with skirts. Main indicators for revision were the progressive radiographic changes indicative of osteolysis, with associated hip pain. Approximately 54% of patients were males and ages ranged from 36 to 76 years of age. Only 7 femoral stems were recovered but all had impingement marks. Only three cases lacked any evidence of stripe wear and these were in very elderly patients. Approximately 85% of these cases showed some evidence of stripe wear and multiple stripes were clearly visible on 50% of the femoral balls. The medial ball stripes were twice as common as lateral. Stripe wear was identified in 25% of CoCr liners.

In the hip simulator studies generally show ‘run-in’ wear rates of 1–7mm3 per million cycles (Mc). We noted that above the 5mm3/Mc threshold, the serum generally appeared black. In contrast, the ‘steady-state’ wear rates of 0.1–1.6 mm3/Mc showed the true potential of MOM bearings. However there were often examples of higher wear (7–20 mm3/Mc), which gave confounding trends in published studies. Our studies of metal ions in the simulator lubricant provided a very accurate representation of MOM wear.

There are many limitations in comparing in-vitro to in-vivo wear performance. Our retrieval data are biased to cases that failed due to hip pain, had radiographic signs of progressive osteolysis and some showed high levels of metal ions. There was also the bias of having predominantly a CoCr sandwich design (polyethylene adaptor). Use of the small ball added the well-known risks of impingement, subluxation and dislocation with rigid cups. Using the ‘damage modes’ from McKellop, we found only normal Mode-1 wear to be rare in these cases, whereas Modes# 2–4 had an incidence approaching 30% each. Signs of impingement were evident in 85% of our cases. Thus summarizing these MOM wear phenomena in retrieved 28mm sandwich cups, the evidence implicated impingement and 3rd-body wear modes (#2–4) as the clinical risk for adverse wear effects at 10 years follow-up. The in-vitro wear studies have not yet simulated such adverse clinical effects.


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_I | Pages 154 - 154
1 Mar 2010
Clarke I Kubo K Lazennec Y Cattonne Y Anderson I Smith E Turnbull A Donaldson T
Full Access

From 1985 metal-on-metal (MOM) designs of resurfacing (RSA) and total hip arthroplasties (THR) have been available over a large diameter range (28–60mm). In-vitro studies indicated satisfactory low wear performance for all designs and diameters tested (wear = 0.1 to 7 mm3). While reports from many centers have been encouraging, some have reported adverse effects. We reviewed clinical and metal ion studies in large diameter retrievals and compared these to 28mm MOM cases. Patients with the latter THR ranged 36–76 years of age and were followed 9–11 years. Main finding in our revisions was osteolysis and pain. The 28mm ball was represented 86% of cases; 71% balls had stripe wear. For liners, 25% had circumferential stripe wear and impingement was evident in 64% cases. Seven cemented stems were recovered with impingement marks; 26 stems were undamaged and therefore not revised. Using the concept of ‘damage modes’ from McKellop, normal wear mode #1 was evident in only 14% of 28mm retrievals whereas incidence of ‘abnormal’ modes #2-4 approached 30% each. Thus the 28mm MOM appeared susceptible to impingement risks with CoCr liners. Summarizing MOM retrievals, damage modes 2–4 were most likely implicated in revisions. The performance of such ‘small diameter’ THRs will be contrasted to our large diameter THR and RSA experience. The questions to be reviewed include, how much of the reported MOM adversity was predictable and how much risk was due to

wear of small diameter MOM,

adverse cup positioning and hip instability,

cup-stem impingement issues or

design conformity issues?


Orthopaedic Proceedings
Vol. 91-B, Issue SUPP_II | Pages 340 - 340
1 May 2009
Chou J Anderson I Astley T Poon P
Full Access

Reverse total shoulder replacement is a viable surgical option for Cuff Tear Arthropathy. Short term results have been promising. Longer term follow-up has demonstrated a high rate of scapular notching. This is attributed to mechanical impingement between the humeral cup and scapular neck when the arm is fully adducted. The long term sequelae of scapular notching are unclear but there is concern that it may compromise fixation of the glenoid component and affect functional outcomes.

Design modifications to address this problem include the newly available eccentric glenospheres and larger diameter glenospheres. These glenospheres are designed to offer greater ranges of motion and theoretically may reduce the risk of impingement and notching. The purpose of this biomechanical study is to demonstrate the difference in range of motions with each design of glenosphere. To our knowledge there is no published literature evaluating this design differences.

The SMR (Lima Orthotec) reverse total shoulder prothesis was implanted into a synthetic bone model (Sawbones, Pacific Laboratories, Vashon, Washington). Four different types of glenospheres (Standard 36 mm, Eccentric 36 mm, Standard 44 mm, Eccentric 44 mm) were then implanted into the same model which was fixed on a measurement table. The precision coordinate measurement device (FARO-Arm, SO6/Rev22, FARO Technologies Inc., Lake Mary, Florida) was used to establish the centres of rotation and ranges of motion.

To date, the collection of data has just been completed, but the data are yet to be analysed. In conclusion, this is a biomechanical study evaluating the ranges of motion and risk of notching, comparing different designs of glenospheres in Reverse Total Shoulder Joint Replacement.


Orthopaedic Proceedings
Vol. 91-B, Issue SUPP_II | Pages 256 - 256
1 May 2009
Sivardeen Z Ali A Jones V Kato Anderson A Madegowda R Raha N Shahane S Stanley D
Full Access

Total elbow arthroplasty (TEA), as a primary procedure and open reduction and internal fixation (ORIF) have been used to treat complex intra-articular distal humeral fractures in elderly patients. The failure rate after ORIF is high and TEA has often been used as a salvage procedure. Although satisfactory results have been reported after TEA as a primary procedure, there are no publications reporting the results of TEA after failed internal fixation (FIF). In this study we compared the results of patients that had TEA after FIF with those that had had primary arthroplasty (PA). We reviewed the results of 9 consecutive patients who had FIF with 12 patients who had PA. All the operations were performed by one surgeon using the same technique and same prosthesis. Both groups of patients were similar with respect to ages, sex, co-morbidity and hand dominance. The mean follow-up for both groups of patients was 5 years. At final review, patients who had had FIF had a mean Mayo score of 68 and a range of flexion/extension of 90 degrees, there was 1 infection and 1 case of loosening. The PA group had a mean Mayo score of 88 and a range of flexion/extension of 96 degrees, there were no cases of infection or loosening. This study shows the results of TEA are satisfactory either as a PA or after FIF, however the results after PA are significantly better than after FIF.


Orthopaedic Proceedings
Vol. 91-B, Issue SUPP_II | Pages 352 - 352
1 May 2009
Graydon A Pitto R Malak S Anderson I
Full Access

Implant malposition remains one of the common causes of total knee replacement (TKR) failure and increased wear. Recent advances in computer technology have made available navigation systems for TKR and other orthopaedic procedures. The purpose of our study was:

to develop a method to assess the accuracy of an image-free TKR navigation system;

to assess its accuracy in a leg with normal or near-normal mechanical axis;

to assess its accuracy in a leg with abnormal mechanical axis.

The system chosen was an image-free system based on electromagnetic technology, the MedTronic AxiEM TKR navigation system. To facilitate measurements, an artificial leg (phantom) was constructed from machined Plexiglas with simulated hip and knee joints. Additional joints located at the midshaft of the tibia and femur allowed deformation in the flexion/extension (y), varus/valgus (x) and rotational (z) planes. Using a highly accurate digital calliper unit (FaroARM Technologies, USA) to precisely measure co-ordinates with pre-machined points on the phantom, a software program was developed to convert these local co-ordinates into a determination of actual leg alignment. This technique was verified using repeated measurement with variable coordinates, giving accuracy to within 0.05 of a degree.

Simulated procedures were then performed with both normal and abnormal leg mechanical axis. At specific points in the procedure, information was compared between the FaroARM digital measurements and the CAS system. Repeated serial measurements were undertaken. In the setting of normal alignment, accuracy to within one degree was demonstrated. In the setting of abnormal x, y and z plane alignment in both femur and tibia, accuracy to within two degrees was demonstrated.

Several clinical studies have been performed to assess the precision of computer navigation in TKR. This study was designed to assess the accuracy of a clinically validated navigation system. The study demonstrates the high level of in-vitro accuracy of the MedTronic AxiEM navigation system in both normal and abnormal mechanical leg alignment settings.


Orthopaedic Proceedings
Vol. 91-B, Issue SUPP_II | Pages 228 - 228
1 May 2009
Anderson J Drosdowech D Faber K MacDermid J
Full Access

This study evaluated the impact of smoking on the surgical outcome of rotator cuff repair controlling for age, gender, and size of tear.

Two hundred and fifty patients were evaluated by a blind evaluator and by self report (SST and WORC questionnaires) at baseline and one year post-op. Types of cuff repair included arthroscopic, mini-open and open procedures. Smoking status was evaluated as a current smoker, quit, or never smoked. Smoking history was subsequently dichotomised into smoker and non-smoker. Generalised linear modeling was used to determine the impact of smoking on surgical outcome using age, gender, and tear size as covariates.

The mean age of the population used was 56+/−11 years in which 70% were males and 30% females. Tear size was distributed amongst this population as small (0–1 cm {44.9%}), moderate (1–3cm {22.7%}), large (3–5cm {15.2%}) and massive (5+cm {17.2%}). All preliminary analyses indicated gender affected tear size and surgical outcomes, and was also associated with smoking status. Due to this confounding effect, males and females were separated for subsequent analysis. The SST questionnaire found smoking to have a significant negative effect on the 1-year l outcomes of males (8.5 vs. 6.1 p=0.025). A similar trend was seen with the WORC (p=0.07). No significant effects were seen for females, but the sample size was underpowered.

Analysis of this population of rotator cuff repairs showed complex interrelationships may exist between gender, age, physical demands and smoking status. The existence of these confounding interrelationships may explain the mixed results seen in the literature concerning smoking and orthopedic procedures. This relatively large cohort established a negative impact of smoking on outcome, after controlling for covariates and confounders. Future research on mediators of cuff outcome should consider potential confounders. Conclusion: Smoking negatively effected surgical outcomes for males but was inconclusive for females. Sex behaved as a confounding variable that masked the smoking effects.


Orthopaedic Proceedings
Vol. 91-B, Issue SUPP_II | Pages 353 - 353
1 May 2009
Shim V Pitto R Streicher R Anderson I
Full Access

A number of densitometry studies have reported dramatic density losses in the acetabular region after uncemented Total Hip Arthroplasty (THA)1,2. However the mechanical implication of such loss is not yet known. This study aims to perform a mechanical analysis with patient specific Finite Element (FE) models to find out how the stress distribution affects the Bone Mineral Density (BMD) changes after uncemented THA.

An existing patient CT dataset collected for a densitometry study was used to generate patient-specific FE models with a previously validated FE mesh generation method3. Boundary and loading conditions included the hip joint force and the forces of 21 muscles attached to the pelvic bone at eight characteristic phases of a gait cycle 4. Tensile and compressive components of principal stresses were calculated after each simulation.

In general, both compressive and tensile principal stresses decreased after uncemented THA but the magnitude of decrease for tensile stresses was much greater than compressive stresses. The changes in tensile stresses were matched with BMD loss patterns. In particular, the densitometry study revealed that areas dorsal to the prosthesis lost more bone density than areas ventral to the prosthesis1. The stress distribution pattern showed that such areas experienced high tensile stress initially and then a dramatic decrease in their magnitude while their compressive stresses remained relatively unchanged. On the other hand, the regions where BMD was maintained - the areas superior to the cup - experienced high compressive stresses initially, which remained relatively high three years after the surgery.

Although it is a result from one patient, results suggest that changes to tensile and compressive stresses might influence BMD differently after uncemented THA. Our hypothesis is that regions with high tensile stress experience bone loss while BMD of the regions with high compressive stress are maintained. More patient datasets are being processed to test this hypothesis. Findings from this study can explain the phenomena of retroacetabular osteolysis, late migration and implant failure of press-fit cups observed in long-term clinical studies.


Orthopaedic Proceedings
Vol. 91-B, Issue SUPP_II | Pages 352 - 352
1 May 2009
Malak S Anderson I Pitto R
Full Access

Implant malposition is one of the most common causes of failure in resurfacing arthroplasty of the hip (RAH). Recent advances in computer technology have made available navigation systems for RAH and other orthopaedic procedures. The purpose of our study was:

to develop a method to assess the accuracy of an image-free RAH navigation system;

to assess its accuracy in a leg with normal anatomy and with deformity of the proximal femur.

We used the Ci-CAS RAH navigation system (DePuy - BrainLab). To facilitate measurements, an artificial leg (phantom) was constructed from machined aluminium with simulated hip and knee joints. The hip and knee articulating surfaces were synthetic bone material (Sawbones – Pacific Laboratories). An additional joint located at the trochanteric region allowed deformation in varus/valgus and ante/retroversion of the head/neck segment. Using a highly accurate digital calliper unit (FaroARM Technologies, USA) to precisely measure co-ordinates with pre-machined points on the phantom, a software program was developed to convert these local co-ordinates into a determination of actual anatomy and leg alignment. This technique was verified using repeated measurement with variable co-ordinates, giving accuracy to within 0.05 of a degree.

Simulated procedures were performed with both normal and abnormal anatomy of the proximal femur. At specific points in the procedure, information was compared between the FaroARM digital measurements and the Ci-CAS system. Repeated serial measurements were undertaken. In the setting of normal alignment, accuracy to within 0.5 degrees was demonstrated. In the setting of abnormal alignment (varus/valgus and ante/retroversion) of the proximal femur, accuracy to within 2 degrees was demonstrated.

To our knowledge, this is the first study to assess accuracy of a RAH navigation system. The study demonstrates a satisfactory level of accuracy for the Ci-CAS in both normal and abnormal anatomical settings. Currently, no international standard or methodology exists against which these results can be compared. In the near future, introduction of new navigation technologies will make crucial the development of international standards for pre-clinical validation of computer-assisted navigation systems. The present study is a first attempt to address this issue.


Orthopaedic Proceedings
Vol. 91-B, Issue SUPP_II | Pages 361 - 361
1 May 2009
Espinosa N Dudda M Anderson J Bernadi M Casser J
Full Access

Background: Calcaneonavicular coalitions (CNC) have been reported to be associated with anatomical aberrations of either the calcaneus and/or navicular bones. These morphological abnormalities may complicate accurate surgical resection. Three-dimensional analysis of spatial orientation and morphological characteristics may help in preoperative planning of resection.

Materials and Methods: Sixteen feet diagnosed with CNC were evaluated by means of 3D CT modeling. Three angles were defined that were expressed in relation to one reproducible landmark (lateral border of the calcaneus): the dorsoplantar inclination, anteroposterior inclination and socket angle. The contact surface area was determined from the depth and width of the coalitions. Three-dimensional reconstructions of the calcanei evaluated the presence and morphology of the anterior calcaneal facet and of a navicular beak. The inter-observer correlations were assessed for the accuracy of the measurement methods. Sixteen normal feet were used as controls for comparison of the socket angle and anatomy of the anterior calcaneal facet and of the navicular beak.

Results: The dorsoplantar inclination angle averaged 50° (±17), the anteroposterior inclination angle 64° (±15), and the pathologic socket angle 98° (±11). The average contact area was 156mm2. Ninety-four percent of all patients in the CNC group revealed a plantar navicular beak. In 50% of those patients the anterior calcaneal facet was replaced by the navicular portion and in 44% the facet was totally missing. In contrast, the socket angle in the control group averaged 77° (± 18), which was found to be statistically different than the CNC group (p=0.0004). Only 25% of the patients in the control group had a plantar navicular beak. Statistically significant inter-observer correlations were found for all measured angles.

Conclusions: Computer aided CT analysis and reconstructions help to determine the spatial orientations of CNC and provide useful information in order to anticipate morphological abnormalities of the calcaneus and navicular.


Orthopaedic Proceedings
Vol. 91-B, Issue SUPP_II | Pages 344 - 344
1 May 2009
Blyth P Stott N Peters I Anderson I
Full Access

Cannulated screw fixation is currently the treatment of choice for slipped capital femoral epiphyses (SCFE). A SCFE module of the Bonedoc simulator was created in order to test the ability of advanced trainees to place the screw in the correct position, and the practicality of using the simulator within the orthopaedic surgery training curriculum.

Bonedoc (University of Auckland) is a virtual reality simulator of image guided orthopaedic operations1. This simulator runs in Internet Explorer (Microsoft, USA) using the Octaga (Octaga, Norway) plugin. The total download is around 4 MB. The SCFE module was created from a CT scan of a Grade 2 acute on chronic SCFE. DICOM images were imported into 3DView (www.rmrsystems.co.uk) and a mesh created. The generic femur from the DHS module was morphed within the CAD package Blender (Blender.org) to conform to this reconstructed SCFE mesh.

Forty two advanced trainees operated on the same virtual SCFE during a training weekend. The trainees had 25 minutes to become familiar with the simulator and complete the operative case. The trainees performed all tasks relevant to the operation. At the operation’s conclusion the trainees self-assessed their performance. Subsequently the simulator provided surgically relevant objective feedback on aspects such as exact position of the screw, misplaced attempts and the number of x-rays. The results were analysed using SAS (SAS Institute, USA) in subgroups based on year on the scheme, as well as correlated within each operation.

There was no difference in the accuracy with which the virtual slipped capital femoral epiphysis was pinned by trainees in different years in the training programme. However, 26 of the 39 of the virtual screws were placed in the superior direction. There was no correlation between number of X-ray images taken and final accuracy of screw placement. The number of misplaced drill holes was correlated both with number of X-ray images taken (p< 0.01) and operative time (p< 0.01) but not with final accuracy of the screw. An increase in misplaced attempts was correlated with angulation errors in the anterior plane (p< 0.01). There was no correlation between the trainees’ self assessment and any of the measured variables.

The Bonedoc simulator provides a means to test trainees on technical aspects of a surgical procedure. It provides objective results, which can mimic real world outcomes. In addition, the ability to test all trainees on the same virtual operative case allows standardisation of assessment. All trainees completed the task to a similar level of accuracy, which may reflect the overall skill level in advanced trainees within the New Zealand. However, many trainees placed the screw in the superior portion of the femoral head, which is thought to increase the risk of avascular necrosis2. Further work is required to evaluate how accurately performance on the simulator predicts performance in the operating theatre


Orthopaedic Proceedings
Vol. 91-B, Issue SUPP_II | Pages 350 - 350
1 May 2009
Oberhofer K Mithraratne K Stott S Walt S Anderson I
Full Access

Cerebral palsy (CP) results from an injury to the immature brain; and it leads to progressive musculoskeletal (MS) impairment in most affected patients. Orthopaedic surgery involving muscle-tendon lengthening is a method for managing short muscles in CP patients. Knowledge of muscle length prior to surgery is beneficial to surgical success. However, using common assessment methods like 3D gait analysis or physical examination, accurate pre-surgery estimation of muscle lengths during walking is difficult.

Computer models of the lower limbs, which provide more insight into muscle functioning during walking, have become increasingly important within the research field of CP. MS models are commonly driven by joint kinematics from clinical gait analysis. The most often used MS model in CP related research is based on the geometry of an adult human man with muscles modelled as line segments. This approach might be reasonable for small muscles with well-defined paths; however, for long muscles with multiple attachment points and curved paths, a more realistic 3D muscle model is required.

The aim of this study is the development of a clinical assessment tool for CP patients by incorporating kinematic data from gait analysis into a 3D finite-element MS model of the lower limbs. Ethical approval has been obtained to develop subject-specific MS models of 12 children with CP and 12 control children (age 8 – 12 years) based on magnetic resonance images. Kinematic data from 3D gait analysis is used as input data to transform the bony structures. Soft-tissue muscle deformation is modelled according to a variant of free-form deformation called the Host-Mesh Fitting Technique. So far, MS models of the lower limbs of three control children and of one child with CP were developed. The resulting muscle length changes during walking agree reasonably well with published data. The proposed modelling approach together with the library of 24 MS models will enable us to develop a powerful tool to investigate gait of children with CP.


Orthopaedic Proceedings
Vol. 91-B, Issue SUPP_II | Pages 342 - 342
1 May 2009
Mutu-Grigg J Malak S Anderson I Cullen J
Full Access

The goal of this study was to determine which of two techniques for the treatment of peri-prosthetic femoral shaft fractures has the greatest torsional integrity. The study designed was a laboratory study, using 13 matched pairs of embalmed femurs. The femurs were implanted with a cemented total hip prosthesis, with a transverse osteotomy distal to the stem. These fractures were fixed either with a metal plate with three proximal unicortical screws and three distal bicortical screws or with three proximal cables and three distal bicortical screws. The fracture fixation was tested to failure in torsion. The pattern of failure and torsional limits were recorded.

There was no significant difference to failure level between the two constructs. Failure with the proximal unicortical screws was usually catastrophic versus non-catastrophic with proximal cables. The femurs were significantly more likely to fracture in internal rotation.

Treatment with proximal cables has the same load to failure in torsion but significantly less complications than with unicortical screws, in agreement with the literature. The findings of the construct being weaker in internal rotation, appears to be a new finding and an area of possible new research.


Orthopaedic Proceedings
Vol. 91-B, Issue SUPP_II | Pages 229 - 229
1 May 2009
Bourne RB Anderson CK Chesworth BM Hornick LE Zaric GS
Full Access

The purpose of this study was to establish a model to predict the future need for total hip and knee replacement surgery over the next ten years.

Analysis based on queuing theory and Ontario data (Ontario Joint Replacement Registry) considered such factors as changing demographics, specific wait time objectives and changing indicators to predict the future need for THR and TKR up to 2015.

26 725 Ontarians were waiting for THR and TKR surgery on any given day in 2004–05. Each month, the number of new decisions for surgery exceeded the actual number of surgeries by over 20%, adding another five hundred patients to the wait list. We predict that the population > fifty-five years of age will increase by 3.4% annually and that the willingness of patients to consider TJR surgery will increase by 8.7%/year To reduce wait times and establish a steady state of waiting (less than 6 months wait), more than 50 000 surgeries per year must be provided within five years and 70 000 total joint replacements per year by 2014–15 as compared to the 31 448 performed annually at this time. Providing this volume of surgeries means that the number of surgeons will have to double within five to seven years.

The results of this queuing theory analysis predict a substantial need for markedly increased THR and TKR volumes and orthopaedic manpower over the next decade.


Orthopaedic Proceedings
Vol. 91-B, Issue SUPP_II | Pages 352 - 352
1 May 2009
Munro J Shim V Pitto R Anderson I
Full Access

Long term clinical follow-up of total hip arthroplasty (THA) has identified problems associated with cyst formation. Such cysts are formed as a result of expansile osteolysis, which starts on a small area of the skeleton and spreads into the bone away from the surface of the prosthesis. Since large areas of the prosthesis are still in immediate contact with the skeleton the prosthesis is not loose and the patients are usually without pain. However this form of osteolysis may destroy large areas of the skeleton before it is detected and result in a sudden fracture due to a weakened skeleton. While there are some short term prospective trials that have shown changes in bone density in the periacetabular region, one needs a biomechanical model to understand factors that influence bone remodeling leading to cyst formation. This study aims to develop a mathematical model for studying the mechanical effects of bone cysts in the acetabulum of THA patients.

2D finite element (FE) models of patients with known restroacetabular cystic disease were generated using coronal CT images from the central region of the acetabulum. The boundary between bone and soft tissue was segmented and an FE model generated. Mesh convergence tests were performed to identify a suitable level of mesh refinement. Three material zones representing– cortical bone (E=17GPa), cancellous bone (E=1GPa) and a titanium cup (E=120GPa) – were included in the model. A series of simulations were run to investigate how cysts affect stress distribution as well as the mechanical consequence of medial wall deficiency.

The presence of a cyst did not alter the pattern of stress distribution in the lateral and medial wall. But the strain energy function increased significantly at the inferior margin of the cyst within its cancellous bone. This may encourage bone formation at the cyst margin and help to explain the sclerotic walls seen in some cysts. Models with absent medial walls showed that both compressive and tensile stresses lowered in the cortical wall and the strain energy function reduced almost to zero. This suggests that a medial wall defect has a high risk of progression.

The current 2D model cannot incorporate complex acetabular geometry or complex forces acting on the hip. Therefore the current model will be further developed into a 3D FE model of the whole pelvis that also represents the pelvic ring structure more adequately. Physiologically meaningful boundary conditions as well as patient specific geometry and material properties will be used to investigate mechanical effects of bone cysts realistically.


Full Access

Lateralisation of the tuberosity tibia causes distal malalignment of the extensor mechanism of the knee and can lead to lateral tracking patella (LTP), resulting in anterior knee pain, or objective patellar instability (OPI), resulting in recurrent luxations. For a precise preoperative diagnosis the tuberositas tibia (TT) trochlear groove (TG) distance was measured on a CT scan. A distance of more than 15 mm was considered to be pathological.

In a prospective study, the clinical results of a subtle, CT-guided medial tuberosity transfer for LTP and OPI were evaluated. 30 Consecutive patients with LTP and 30 patients with OPI and an increased TT TG were included. Outcomes were documented at 3, 12 and 24 months follow-up using the Lysholm scale, the Kujala score, and a visual analogue pain score. Postoperatively all but one patient reported good improvement in stability (no persistent subluxations or luxations). All patients had a marked improvement in pain and functional scores at follow up. Complications seem to be related to the peroperative technique. CT-guided TT transfer appears to be satisfactory and safe method for treating patients with an increased TT TG leading to either LTP or OPI.


Orthopaedic Proceedings
Vol. 91-B, Issue SUPP_I | Pages 60 - 60
1 Mar 2009
Fountain J Anderson A Flowers M Bell M
Full Access

Introduction: This study examined the cohort of patients selectively screened over a 5 year period with ultrasonography according to our risk factors (positive Ortolani or Barlow manoeuvre, breech presentation, first degree affected relative and talipes equinovarus) for developmental hip dysplasia (DDH). The aims were to evaluate the success of those managed in a Pavlik harness and identify predictive factors for those that failed treatment.

Methods: 1181 patients were selectively screened between 1999 and 2004. Of those, 128 patients (189 hips) were identified as having hip instability. Failure was defined as inability to achieve or maintain hip reduction in a Pavlik harness. A proforma was designed to document patients’ risk factors and ultrasound findings at time of initial dynamic ultrasound scan where the senior radiographer and treating consultant were present. Each hip was classified according to Graf type. Acetabular indices were recorded prior to discharge.

Results: All 128 patients with hip instability were managed in a Pavlik harness. This was abandoned for surgical treatment in 9 patients (10 hips) giving a failure rate of 5.3 % (0.17 per 1000 live births). All those successfully managed had an acetabular index of less than 30 degrees at follow up (6 – 48 months). 7 hips in the series were classified as Graf type IV, of these, 6 went on to fail management in a Pavlik harness. 67% of those that failed were also breech presentation compared to 22% of those managed successfully. There were no complications associated with management in a Pavlik harness. 16 patients born within our region presented after 12 weeks of age with DDH resulting in a late presentation rate of 0.3 per 1000 live births.

Discussion: Our overall rate of selective screening is 14 per 1000 live births with a subsequent treatment rate of 2.3 per 1000 is comparable with other centres. Our rate of failure for DDH in a Pavlik harness 0.17 per 1000 live births is an improvement on any previously published results. Irreducible hips, Graf type IV hips and breech presentation correlated with a high likelihood of treatment failure.


Orthopaedic Proceedings
Vol. 90-B, Issue SUPP_II | Pages 392 - 392
1 Jul 2008
Pollintine P Cooper I Anderson H Green L Cooper C Lanham S Oreffo R Dolan P
Full Access

Introduction: Epidemiology suggests that an intrauterine nutrient restriction increases the likelihood of osteoporosis in later life, possibly due to differences in bone structure and strength. We hypothesise that, in an ovine model, early nutritional compromise reduces vertebral cancellous bone density and cortical thickness, and thereby reduces vertebral compressive strength.

Materials and methods: Lumbar spines were dissected from 8 sheep (6 male, 2 female: mean age 2.7 yrs). Spines were divided into different groups, based on the early diet of the sheep: group CC received a control diet, group IU received low protein in utero, and group PN received low protein both in utero and postnatally. Fifteen motion segments (consisting of two vertebrae and the intervening disc and ligaments) were prepared from the spines, and compressed to failure using a hydraulically-controlled materials testing machine to obtain yield strength. 1mm-thick bone slices were taken from the mid-sagittal and para-sagittal regions of each vertebral body and micro-radiographed. Digital images of the micro-radiographs were analysed to obtain the cancellous bone density in anterior and posterior regions, and the cortical thickness in the anterior, posterior, superior and inferior regions. Repeated measures ANOVA was used to test for differences in parameters at the different locations, and between the groups.

Results: The anterior cortex was 28% thinner for the IU group, and 23% thinner for the PN group compared to controls (both p< 0.001). In the PN group, the superior cortex was also 18% thinner than controls (p< 0.02). There was no significant difference between cancellous bone density in either region. Yield strength was 16% lower in the IU group compared to controls, but this did not reach significance.

Discussion: In the nutritionally compromised groups, cortical thickness was lower in regions of the vertebral body where fractures often occur in elderly people. However, the reduction in cortical thickness is not accompanied by a significant reduction in compressive strength in the sheep model. These findings suggest that the well-maintained cancellous bone protects the vertebra from fracture.


Orthopaedic Proceedings
Vol. 90-B, Issue SUPP_I | Pages 155 - 155
1 Mar 2008
Shim V Anderson I Rossaak M Streicher R Pitto R
Full Access

In recent years, some attempts have been made to develop a method that generates finite element (FE) models of the femur and pelvis using CT. However, due to the complex bone geometry, most of these methods require an excessive amount of CT radiation dosage. Here we describe a method for generating accurate patient-specific FE models of the total hip using a small number of CT scans in order to reduce radiation exposure.

A previously reported method for autogenerating patient-specific FE models of the femur was extended to include the pelvis. CT osteodensitometry was performed on 3 patients who had hip replacement surgery and patient-specific FE models of the total hip were generated. The pelvis was generated with a new technique that incorporated a mesh morphing method called ‘host mesh fitting’. It used an existing generic mesh and then morphed it to reflect the patient specific geometry. This can be used to morph the whole pelvis, but our patient dataset was limited to the acetabulum. An algorithm was developed that automated all the procedures involved in the fitting process.

Average error between the fitted mesh and patient specific data sets for the femur was less than 1mm. The error for the pelvis was about 2.5mm. This was when a total 18 CT scans with 10mm gap were used – 12 of the femur, and 6 of the pelvis. There was no element distortion and a smooth element surface was achieved.

Previously, we reported a new method for automatically generating a FE model of the femur with as few CT scans as possible. Here we describe a technique that customizes a generic pelvis mesh to patient-specific data sets. Thus we have developed a novel hybrid technique which can generate an accurate FE model of the total hip using significantly less CT scans.

An automated method of generating FE models for the total hip with reduced CT radiation exposure will be a valuable clinical tool for surgeons.


Orthopaedic Proceedings
Vol. 90-B, Issue SUPP_I | Pages 155 - 155
1 Mar 2008
Shim V Anderson I Rossaak M Streicher R Pitto R
Full Access

In recent years, some attempts have been made to develop a method that generates finite element (FE) models of the femur and pelvis using CT. However, due to the complex bone geometry, most of these methods require an excessive amount of CT radiation dosage. Here we describe a method for generating accurate patient-specific FE models of the total hip using a small number of CT scans in order to reduce radiation exposure.

A previously reported method for autogenerating patient-specific FE models of the femur was extended to include the pelvis. CT osteodensitometry was performed on 3 patients who had hip replacement surgery and patient-specific FE models of the total hip were generated. The pelvis was generated with a new technique that incorporated a mesh morphing method called ‘host mesh fitting’. It used an existing generic mesh and then morphed it to reflect the patient specific geometry. This can be used to morph the whole pelvis, but our patient dataset was limited to the acetabulum. An algorithm was developed that automated all the procedures involved in the fitting process.

Average error between the fitted mesh and patient specific data sets for the femur was less than 1mm. The error for the pelvis was about 2.5mm. This was when a total 18 CT scans with 10mm gap were used – 12 of the femur, and 6 of the pelvis. There was no element distortion and a smooth element surface was achieved.

Previously, we reported a new method for automatically generating a FE model of the femur with as few CT scans as possible. Here we describe a technique that customizes a generic pelvis mesh to patient-specific data sets. Thus we have developed a novel hybrid technique which can generate an accurate FE model of the total hip using significantly less CT scans.


Orthopaedic Proceedings
Vol. 90-B, Issue SUPP_I | Pages 166 - 166
1 Mar 2008
Graydon A Malek S Anderson I Pitto R
Full Access

The correct positioning of implant components in total knee replacement (TKR) is important for a successful long-term outcome. In order to address the problems inherent with conventional alignment methods, several computer-assisted navigation systems (CAS) have been developed. Despite numerous reports of clinical outcomes and system reliability, there is a lack of studies independently evaluating the precision and accuracy of such systems. We report on the design and development of a method and device to evaluate the accuracy of such a computer-assisted navigation system in two situations; 1) Normal or near-normal lower limb mechanical axis, and 2)Simulated femoral and/or tibial extra-articular deformity in either varus/valgus (x), internal/external rotation (y) or flexion/extension (z) planes.

The system assessed was the Ci Knee-CAS navigation system (BrainLab/De Puy). This image-free system requires the registration of specific anatomical points to identify the mechanical axis of the lower limb and therefore provide information on resection level and alignment. In order to precisely measure and accurately reproduce these points we constructed a phantom device along anatomical guidelines, with lockable joints located at the mid-shaft of both femur and tibia. We then identified geometric CAS data; 1) Tibial resection height, and 2) Tibial resection plane, and using specially written software compared this against validated co-ordinate measurements independently obtained by a FaroArm co-ordinate measurement system (FARO Technologies, USA). This enabled data from the navigation system to be directly compared against highly accurate reference measurements.

Accuracy of the system was then assessed with both normal mechanical alignment of the lower limbs and simulated extra-articular deformity.


Orthopaedic Proceedings
Vol. 88-B, Issue SUPP_III | Pages 406 - 407
1 Oct 2006
Anderson R Gadina M Houghton A Li G
Full Access

Introduction: Fibroblast growth factor receptor 3 (FGFR3) is a tyrosine kinase membrane-spanning protein whose function is to regulate chondrocyte proliferation, differentiation and matrix production during cartilage development. Several mutations in FGFR3 have now been documented to link to human diseases. A number of these mutations result in constitutive activation of the FGFR3, leading to proliferation and premature differentiation of chondrocytes. Depending on the mutation and the resultant level of FGFR3 activation, mild to severe skeletal dysplasias such as achondroplasia (ACH), hypochondroplasia (HCH), thanatophoric dysplasia type I (TDI) and type II (TDII), and severe achondroplasia with developmental delay and acanthosis nigrans (SADDAN) may result. It has been postulated that the signalling pathways downstream of FGFR3 may be responsible for activating transcription factors, leading to up-regulation of cell cycle inhibitors and causing abnormal suppression of chondrocyte cell proliferation. However, the precise signalling pathways involved in FGFR3 mutation have as yet to be elucidated. The aim of this study was to investigate and compare the differences in the downstream signalling pathways between FGFR3 mutants.

Methods and Results: Wild type FGFR3 has been cloned into expression vector pcDNA3 and the construct has been used to generate four different FGFR3 mutants using site-directed mutagenesis. The mutations which have been introduced and the types of dysplasia they correspond to were as follows: K380R (ACH), N540K (HCH) and K650E (TDII). A kinase dead form of the receptor, K504R has also been generated. Wild type and each of the four mutant FGFR3 proteins in pcDNA3 vector have been successfully transfected into 293T cells using the calcium phosphate method. Immunoprecipitation and Western Blot analysis of cell lysates revealed expression of wild type protein in three isoforms of size 135kDa (mature), 120kDa (intermediate) and 98kDa (immature). The mutant proteins all followed a similar pattern of expression with the exception of the TDII mutant that did not express the mature form of the FGFR3. Changes in MAPK, PLCã and STAT 1 signalling pathways in response to FGFs-1, 2, 9 and 18 in the 293-cells of wild type and mutant forms of FGFR3 are now under investigation, in an attempt to define which pathways are mostly responsible for the resultant abnormal phenotypes.

Discussion: Genomics studies have demonstrated that FGFR3 expression is significantly upregulated during the osteoblastic differentiation of mesenchymal stem cells (MSCs) under BMP-2 stimulation in vitro. Subsequent functional studies have demonstrated that a selective ligand for FGFR3, FGF9, is able to induce tyrosine kinase signalling, and the osteoblastic differentiation of MSCs in vitro. Further understanding the signalling mechanisms of FGFR3 activation in normal and mutant forms may lead to discover potential anabolic agents that are based on FGFR3-FGFs pathways.