Advertisement for orthosearch.org.uk
Results 861 - 880 of 1610
Results per page:
The Bone & Joint Journal
Vol. 95-B, Issue 11 | Pages 1453 - 1457
1 Nov 2013
Zlotorowicz M Czubak J Caban A Kozinski P Boguslawska-Walecka R

The femoral head receives blood supply mainly from the deep branch of the medial femoral circumflex artery (MFCA). In previous studies we have performed anatomical dissections of 16 specimens and subsequently visualised the arteries supplying the femoral head in 55 healthy individuals. In this further radiological study we compared the arterial supply of the femoral head in 35 patients (34 men and one woman, mean age 37.1 years (16 to 64)) with a fracture/dislocation of the hip with a historical control group of 55 hips. Using CT angiography, we identified the three main arteries supplying the femoral head: the deep branch and the postero-inferior nutrient artery both arising from the MFCA, and the piriformis branch of the inferior gluteal artery. It was possible to visualise changes in blood flow after fracture/dislocation.

Our results suggest that blood flow is present after reduction of the dislocated hip. The deep branch of the MFCA was patent and contrast-enhanced in 32 patients, and the diameter of this branch was significantly larger in the fracture/dislocation group than in the control group (p = 0.022). In a subgroup of ten patients with avascular necrosis (AVN) of the femoral head, we found a contrast-enhanced deep branch of the MFCA in eight hips. Two patients with no blood flow in any of the three main arteries supplying the femoral head developed AVN.

Cite this article: Bone Joint J 2013;95-B:1453–7.


The Bone & Joint Journal
Vol. 95-B, Issue 11_Supple_A | Pages 88 - 91
1 Nov 2013
Su EP Su SL

Surface hip replacement (SHR) is generally used in younger, active patients as an alternative conventional total hip replacement in part because of the ability to preserve femoral bone. This major benefit of surface replacement will only hold true if revision procedures of SHRs are found to provide good clinical results.

A retrospective review of SHR revisions between 2007 and 2012 was presented, and the type of revision and aetiologies were recorded. There were 55 SHR revisions, of which 27 were in women. At a mean follow-up of 2.3 years (0.72 to 6.4), the mean post-operative Harris hip score (HHS) was 94.8 (66 to 100). Overall 23 were revised for mechanical reasons, nine for impingement, 13 for metallosis, nine for unexplained pain and one for sepsis. Of the type of revision surgery performed, 14 were femoral-only revisions; four were acetabular-only revisions, and 37 were complete revisions.

We did not find that clinical scores were significantly different between gender or different types of revisions. However, the mean post-operative HHS was significantly lower in patients revised for unexplained pain compared with patients revised for mechanical reasons (86.9 (66 to 100) versus 99 (96 to 100); p = 0.029). There were two re-revisions for infection in the entire cohort.

Based on the overall clinical results, we believe that revision of SHR can have good or excellent results and warrants a continued use of the procedure in selected patients. Close monitoring of these patients facilitates early intervention, as we believe that tissue damage may be related to the duration of an ongoing problem. There should be a low threshold to revise a surface replacement if there is component malposition, rising metal ion levels, or evidence of soft-tissue abnormalities.

Cite this article: Bone Joint J 2013;95-B, Supple A:88–91.


The Bone & Joint Journal
Vol. 95-B, Issue 11_Supple_A | Pages 74 - 76
1 Nov 2013
Kamath AF McAuliffe CL Gutsche JT Kosseim LM Hume EL Baldwin KD Kornfield Z Israelite CL

Patient safety is a critical issue in elective total joint replacement surgery. Identifying risk factors that might predict complications and intensive care unit (ICU) admission proves instrumental in reducing morbidity and mortality. The institution’s experience with risk stratification and pre-operative ICU triage has resulted in a reduction in unplanned ICU admissions and post-operative complications after total hip replacement. The application of the prediction tools to total knee replacement has proven less robust so far. This work also reviews areas for future research in patient safety and cost containment.

Cite this article: Bone Joint J 2013;95-B, Supple A:74–6.


The Bone & Joint Journal
Vol. 95-B, Issue 11_Supple_A | Pages 70 - 73
1 Nov 2013
Lanting BA MacDonald SJ

Total hip replacement (THR) is a very common procedure undertaken in up to 285 000 Americans each year. Patient satisfaction with THR is very high, with improvements in general health, quality of life, and function while at the same time very cost effective. Although the majority of patients have a high degree of satisfaction with their THR, 27% experience some discomfort, and up to 6% experience severe chronic pain. Although it can be difficult to diagnose the cause of the pain in these patients, this clinical issue should be approached systematically and thoroughly. A detailed history and clinical examination can often provide the correct diagnosis and guide the appropriate selection of investigations, which will then serve to confirm the clinical diagnosis made.

Cite this article: Bone Joint J 2013;95-B, Supple A:70–3.


The Bone & Joint Journal
Vol. 95-B, Issue 11_Supple_A | Pages 109 - 113
1 Nov 2013
Petrie J Sassoon A Haidukewych GJ

Pelvic discontinuity represents a rare but challenging problem for orthopaedic surgeons. It is most commonly encountered during revision total hip replacement, but can also result from an iatrogentic acetabular fracture during hip replacement. The general principles in management of pelvic discontinuity include restoration of the continuity between the ilium and the ischium, typically with some form of plating. Bone grafting is frequently required to restore pelvic bone stock. The acetabular component is then impacted, typically using an uncemented, trabecular metal component. Fixation with multiple supplemental screws is performed. For larger defects, a so-called ‘cup–cage’ reconstruction, or a custom triflange implant may be required. Pre-operative CT scanning can greatly assist in planning and evaluating the remaining bone stock available for bony ingrowth. Generally, good results have been reported for constructs that restore stability to the pelvis and allow some form of biologic ingrowth.

Cite this article: Bone Joint J 2013;95-B, Supple A:109–13.


The Bone & Joint Journal
Vol. 95-B, Issue 11_Supple_A | Pages 46 - 50
1 Nov 2013
Issa K Pivec R Kapadia BH Banerjee S Mont MA

Symptomatic hip osteonecrosis is a disabling condition with a poorly understood aetiology and pathogenesis. Numerous treatment options for hip osteonecrosis are described, which include non-operative management and joint preserving procedures, as well as total hip replacement (THR). Non-operative or joint preserving treatment may improve outcomes when an early diagnosis is made before the lesion has become too large or there is radiographic evidence of femoral head collapse. The presence of a crescent sign, femoral head flattening, and acetabular involvement indicate a more advanced-stage disease in which joint preserving options are less effective than THR. Since many patients present after disease progression, primary THR is often the only reliable treatment option available. Prior to the 1990s, outcomes of THR for osteonecrosis were poor. However, according to recent reports and systemic reviews, it is encouraging that with the introduction of newer ceramic and/or highly cross-linked polyethylene bearings as well as highly-porous fixation interfaces, THR appears to be a reliable option in the management of end-stage arthritis following hip osteonecrosis in this historically difficult to treat patient population.

Cite this article: Bone Joint J 2013;95-B, Supple A:46–50.


The Bone & Joint Journal
Vol. 95-B, Issue 11_Supple_A | Pages 77 - 83
1 Nov 2013
Gehrke T Zahar A Kendoff D

Based on the first implementation of mixing antibiotics into bone cement in the 1970s, the Endo-Klinik has used one stage exchange for prosthetic joint infection (PJI) in over 85% of cases. Looking carefully at current literature and guidelines for PJI treatment, there is no clear evidence that a two stage procedure has a higher success rate than a one-stage approach. A cemented one-stage exchange potentially offers certain advantages, mainly based on the need for only one operative procedure, reduced antibiotics and hospitalisation time. In order to fulfill a one-stage approach, there are obligatory pre-, peri- and post-operative details that need to be meticulously respected, and are described in detail. Essential pre-operative diagnostic testing is based on the joint aspiration with an exact identification of any bacteria. The presence of a positive bacterial culture and respective antibiogram are essential, to specify the antibiotics to be loaded to the bone cement, which allows a high local antibiotic elution directly at the surgical side. A specific antibiotic treatment plan is generated by a microbiologist. The surgical success relies on the complete removal of all pre-existing hardware, including cement and restrictors and an aggressive and complete debridement of any infected soft tissues and bone material. Post-operative systemic antibiotic administration is usually completed after only ten to 14 days.

Cite this article: Bone Joint J 2013;95-B, Supple A:77–83.


The Bone & Joint Journal
Vol. 95-B, Issue 11_Supple_A | Pages 41 - 45
1 Nov 2013
Zywiel MG Mont MA Callaghan JJ Clohisy JC Kosashvili Y Backstein D Gross AE

Down’s syndrome is associated with a number of musculoskeletal abnormalities, some of which predispose patients to early symptomatic arthritis of the hip. The purpose of the present study was to review the general and hip-specific factors potentially compromising total hip replacement (THR) in patients with Down’s syndrome, as well as to summarise both the surgical techniques that may anticipate the potential adverse impact of these factors and the clinical results reported to date. A search of the literature was performed, and the findings further informed by the authors’ clinical experience, as well as that of the hip replacement in Down Syndrome study group. The general factors identified include a high incidence of ligamentous laxity, as well as associated muscle hypotonia and gait abnormalities. Hip-specific factors include: a high incidence of hip dysplasia, as well as a number of other acetabular, femoral and combined femoroacetabular anatomical variations. Four studies encompassing 42 hips, which reported the clinical outcomes of THR in patients with Down’s syndrome, were identified. All patients were successfully treated with standard acetabular and femoral components. The use of supplementary acetabular screw fixation to enhance component stability was frequently reported. The use of constrained liners to treat intra-operative instability occurred in eight hips. Survival rates of between 81% and 100% at a mean follow-up of 105 months (6 to 292) are encouraging. Overall, while THR in patients with Down’s syndrome does present some unique challenges, the overall clinical results are good, providing these patients with reliable pain relief and good function.

Cite this article: Bone Joint J 2013;95-B, Supple A:41–5.


The Bone & Joint Journal
Vol. 95-B, Issue 10 | Pages 1320 - 1325
1 Oct 2013
Tamura S Nishii T Takao M Sakai T Yoshikawa H Sugano N

We investigated differences in the location and mode of labral tears between dysplastic hips and hips with femoroacetabular impingement (FAI). We also investigated the relationship between labral tear and adjacent cartilage damage. We retrospectively studied 72 symptomatic hips (in 68 patients: 19 men and 49 women) with radiological evidence of dysplasia or FAI on high-resolution CT arthrography. The incidence and location of labral tears and modes of tear associated with the base of the labrum (Mode 1) or body of the labrum (Mode 2) were compared among FAI, mildly dysplastic and severely dysplastic hips. The locations predominantly involved with labral tears were different in FAI and mild dysplastic hips (anterior and anterosuperior zones) and in severely dysplastic hips (anterosuperior and superior zones) around the acetabulum. Significant differences were observed in the prevalence of Mode 1 versus Mode 2 tears in FAI hips (72% (n = 13) vs 28% (n = 5)) and severe dysplastic hips (25% (n = 2) vs 75% (n = 6)). The frequency of cartilage damage adjacent to Mode 1 tears was significantly higher (42% (n = 14)) than that adjacent to Mode 2 tears (14% (n = 3)).

Hip pathology is significantly related to the locations and modes of labral tears. Mode 1 tears may be a risk factor for the development of adjacent acetabular cartilage damage.

Cite this article: Bone Joint J 2013;95-B:1320–5.


The Bone & Joint Journal
Vol. 95-B, Issue 10 | Pages 1332 - 1338
1 Oct 2013
Van Der Straeten C Van Quickenborne D De Roest B Calistri A Victor J De Smet K

A retrospective study was conducted to investigate the changes in metal ion levels in a consecutive series of Birmingham Hip Resurfacings (BHRs) at a minimum ten-year follow-up. We reviewed 250 BHRs implanted in 232 patients between 1998 and 2001. Implant survival, clinical outcome (Harris hip score), radiographs and serum chromium (Cr) and cobalt (Co) ion levels were assessed.

Of 232 patients, 18 were dead (five bilateral BHRs), 15 lost to follow-up and ten had been revised. The remaining 202 BHRs in 190 patients (136 men and 54 women; mean age at surgery 50.5 years (17 to 76)) were evaluated at a minimum follow-up of ten years (mean 10.8 years (10 to 13.6)). The overall implant survival at 13.2 years was 92.4% (95% confidence interval 90.8 to 94.0). The mean Harris hip score was 97.7 (median 100; 65 to 100). Median and mean ion levels were low for unilateral resurfacings (Cr: median 1.3 µg/l, mean 1.95 µg/l (< 0.5 to 16.2); Co: median 1.0 µg/l, mean 1.62 µg/l (< 0.5 to 17.3)) and bilateral resurfacings (Cr: median 3.2 µg/l, mean 3.46 µg/l (< 0.5 to 10.0); Co: median 2.3 µg/l, mean 2.66 µg/l (< 0.5 to 9.5)). In 80 unilateral BHRs with sequential ion measurements, Cr and Co levels were found to decrease significantly (p < 0.001) from the initial assessment at a median of six years (4 to 8) to the last assessment at a median of 11 years (9 to 13), with a mean reduction of 1.24 µg/l for Cr and 0.88 µg/l for Co. Three female patients had a > 2.5 µg/l increase of Co ions, associated with head sizes ≤ 50 mm, clinical symptoms and osteolysis. Overall, there was no significant difference in change of ion levels between genders (Cr, p = 0.845; Co, p = 0.310) or component sizes (Cr, p = 0.505; Co, p = 0.370). Higher acetabular component inclination angles correlated with greater change in ion levels (Cr, p = 0.013; Co, p = 0.002). Patients with increased ion levels had lower Harris hip scores (p = 0.038).

In conclusion, in well-functioning BHRs the metal ion levels decreased significantly at ten years. An increase > 2.5 µg/l was associated with poor function.

Cite this article: Bone Joint J 2013;95-B:1332–8.


The Bone & Joint Journal
Vol. 95-B, Issue 10 | Pages 1326 - 1331
1 Oct 2013
Eilander W Harris SJ Henkus HE Cobb JP Hogervorst T

Orientation of the acetabular component influences wear, range of movement and the incidence of dislocation after total hip replacement (THR). During surgery, such orientation is often referenced to the anterior pelvic plane (APP), but APP inclination relative to the coronal plane (pelvic tilt) varies substantially between individuals. In contrast, the change in pelvic tilt from supine to standing (dPT) is small for nearly all individuals. Therefore, in THR performed with the patient supine and the patient’s coronal plane parallel to the operating table, we propose that freehand placement of the acetabular component placement is reliable and reflects standing (functional) cup position. We examined this hypothesis in 56 hips in 56 patients (19 men) with a mean age of 61 years (29 to 80) using three-dimensional CT pelvic reconstructions and standing lateral pelvic radiographs. We found a low variability of acetabular component placement, with 46 implants (82%) placed within a combined range of 30° to 50° inclination and 5° to 25° anteversion. Changing from the supine to the standing position (analysed in 47 patients) was associated with an anteversion change < 10° in 45 patients (96%). dPT was < 10° in 41 patients (87%). In conclusion, supine THR appears to provide reliable freehand acetabular component placement. In most patients a small reclination of the pelvis going from supine to standing causes a small increase in anteversion of the acetabular component.

Cite this article: Bone Joint J 2013;95-B:1326–31.


The Bone & Joint Journal
Vol. 95-B, Issue 9 | Pages 1178 - 1183
1 Sep 2013
Li H Mao Y Oni JK Dai K Zhu Z

In developmental dysplasia of the hip (DDH), a bone defect is often observed superior to the acetabulum after the reconstruction at the level of the true acetabulum during total hip replacement (THR). However, the essential amount of uncemented acetabular component coverage required for a satisfactory outcome remains controversial. The purpose of this study was to assess the stability and function of acetabular components with a lack of coverage > 30% (31% to 50%). A total of 760 DDH patients underwent THR with acetabular reconstruction at the level of the true floor. Lack of coverage above the acetabular component of > 30% occurred in 56 patients. Intra-operatively, autogenous morcellised bone grafts were used to fill the uncovered portion. Other than two screws inserted through the acetabular shell, no additional structural supports were used in these hips. In all, four patients were lost to follow-up. Therefore, 52 patients (52 hips, 41 women and 11 men) with a mean age of 60.1 years (42 to 78) were available for this study at a mean of 4.8 years (3 to 7). There were no instances of prosthesis revision or marked loosening during the follow-up. The Harris hip score improved from a mean of 40.7 points (sd 12.2) pre-operatively to 91.1 (sd 5.0) at the last follow-up. Radiological analysis with medical imaging software allowed us to calculate the extent of the uncoverage in terms of the uncovered arc of the implant as viewed on the anteroposterior pelvic radiograph. From this we propose that up to 17 mm of lateral undercoverage in the presence of a stable initial implantation in the presence of bone autografting, with an inclination angle of the acetabular component between 40° and 55°, is acceptable. This represents undercoverage of ≤ 50%.

Cite this article: Bone Joint J 2013;95-B:1178–83.


The Bone & Joint Journal
Vol. 95-B, Issue 9 | Pages 1184 - 1191
1 Sep 2013
Gordon M Stark A Sköldenberg OG Kärrholm J Garellick G

While an increasing amount of arthroplasty articles report comorbidity measures, none have been validated for outcomes. In this study, we compared commonly used International Classification of Diseases-based comorbidity measures with re-operation rates after total hip replacement (THR). Scores used included the Charlson, the Royal College of Surgeons Charlson, and the Elixhauser comorbidity score. We identified a nationwide cohort of 134 423 THRs from the Swedish Hip Arthroplasty Register. Re-operations were registered post-operatively for up to 12 years. The hazard ratio was estimated by Cox’s proportional hazards regression, and we used C-statistics to assess each measure’s ability to predict re-operation. Confounding variables were age, gender, type of implant fixation, hospital category, hospital implant volume and year of surgery.

In the first two years only the Elixhauser score showed any significant relationship with increased risk of re-operation, with increased scores for both one to two and three or more comorbidities. However, the predictive C-statistic in this period for the Elixhauser score was poor (0.52). None of the measures proved to be of any value between two and 12 years. They might be of value in large cohort or registry studies, but not for the individual patient.

Cite this article: Bone Joint J 2013;95-B:1184–91.


The Bone & Joint Journal
Vol. 95-B, Issue 9 | Pages 1192 - 1196
1 Sep 2013
Okano K Yamaguchi K Ninomiya Y Matsubayashi S Osaki M Takahashi K

Patients with acetabular dysplasia commonly undergo peri-acetabular osteotomy after skeletal maturity to reduce the risk of the late development of osteoarthritis. Several studies have suggested that deformity of the femoral head influences the long-term outcome. We radiologically examined 224 hips in 112 patients with acetabular dysplasia and early-stage osteoarthritis. There were 103 women and nine men with a mean age of 37.6 years (18 to 49). A total of 201 hips were placed in the acetabular dysplasia group and 23 in a normal group. The centre–edge angle and acetabular head index were significantly smaller (both p < 0.001), and the acetabular angle, acetabular roof angle and roundness index were significantly greater in the acetabular dysplasia group than those in the normal group (all p < 0.001). There were significant correlations between the roundness index and other parameters. Femoral head shape may be influenced by the severity of the acetabular dysplasia.

Cite this article: Bone Joint J 2013;95-B:1192–6.


The Bone & Joint Journal
Vol. 95-B, Issue 9 | Pages 1172 - 1177
1 Sep 2013
Matharu GS McBryde CW Pynsent WB Pynsent PB Treacy RBC

We report the long-term survival and functional outcome of the Birmingham Hip Resurfacing (BHR) in patients aged < 50 years at operation, and explore the factors affecting survival. Between 1997 and 2006, a total of 447 BHRs were implanted in 393 patients (mean age 41.5 years (14.9 to 49.9)) by one designing surgeon. The mean follow-up was 10.1 years (5.2 to 14.7), with no loss to follow-up. In all, 16 hips (3.6%) in 15 patients were revised, giving an overall cumulative survival of 96.3% (95% confidence interval (CI) 93.7 to 98.3) at ten years and 94.1% (95% CI 84.9 to 97.3) at 14 years. Using aseptic revision as the endpoint, the survival for men with primary osteoarthritis (n = 195) was 100% (95% CI 100 to 100) at both ten years and 14 years, and in women with primary osteoarthritis (n = 109) it was 96.1% (95% CI 90.1 to 99.9) at ten years and 91.2% (95% CI 68.6 to 98.7) at 14 years. Female gender (p = 0.047) and decreasing femoral head size (p = 0.044) were significantly associated with an increased risk of revision. The median Oxford hip score (OHS, modified as a percentage with 100% indicating worst outcome) at last follow-up was 4.2% (46 of 48; interquartile range (IQR) 0% to 24%) and the median University of California, Los Angeles (UCLA) score was 6.0 (IQR 5 to 8). Men had significantly better OHS (p = 0.02) and UCLA scores (p = 0.01) than women. The BHR provides excellent survival and functional results in men into the second decade, with good results achieved in appropriately selected women.

Cite this article: Bone Joint J 2013;95-B:1172–7.


Bone & Joint Research
Vol. 2, Issue 9 | Pages 200 - 205
1 Sep 2013
Amarasekera HW Campbell PC Parsons N Achten J Masters J Griffin DR Costa ML

Objectives

We aimed to determine the effect of surgical approach on the histology of the femoral head following resurfacing of the hip.

Methods

We performed a histological assessment of the bone under the femoral component taken from retrieval specimens of patients having revision surgery following resurfacing of the hip. We compared the number of empty lacunae in specimens from patients who had originally had a posterior surgical approach with the number in patients having alternative surgical approaches.


The Bone & Joint Journal
Vol. 95-B, Issue 8 | Pages 1035 - 1039
1 Aug 2013
Ebreo D Bell PJ Arshad H Donell ST Toms A Nolan JF

Metal artefact reduction (MAR) MRI is now widely considered to be the standard for imaging metal-on-metal (MoM) hip implants. The Medicines and Healthcare Products Regulatory Agency (MHRA) has recommended cross-sectional imaging for all patients with symptomatic MoM bearings. This paper describes the natural history of MoM disease in a 28 mm MoM total hip replacement (THR) using MAR MRI. Inclusion criteria were patients with MoM THRs who had not been revised and had at least two serial MAR MRI scans. All examinations were reported by an experienced observer and classified as A (normal), B (infection) or C1–C3 (mild, moderate, severe MoM-related abnormalities). Between 2002 and 2011 a total of 239 MRIs were performed on 80 patients (two to four scans per THR); 63 initial MRIs (61%) were normal. On subsequent MRIs, six initially normal scans (9.5%) showed progression to a disease state; 15 (15%) of 103 THRs with sequential scans demonstrated worsening disease on subsequent imaging.

Most patients with a MoM THR who do not undergo early revision have normal MRI scans. Late progression (from normal to abnormal, or from mild to more severe MoM disease) is not common and takes place over several years.

Cite this article: Bone Joint J 2013;95-B:1035–9.


Bone & Joint Research
Vol. 2, Issue 8 | Pages 140 - 148
1 Aug 2013
Gauthier L Dinh L Beaulé PE

Objectives

To quantify and compare peri-acetabular bone mineral density (BMD) between a monoblock acetabular component using a metal-on-metal (MoM) bearing and a modular titanium shell with a polyethylene (PE) insert. The secondary outcome was to measure patient-reported clinical function.

Methods

A total of 50 patients (25 per group) were randomised to MoM or metal-on-polyethlene (MoP). There were 27 women (11 MoM) and 23 men (14 MoM) with a mean age of 61.6 years (47.7 to 73.2). Measurements of peri-prosthetic acetabular and contralateral hip (covariate) BMD were performed at baseline and at one and two years’ follow-up. The Western Ontario and McMaster Universities osteoarthritis index (WOMAC), University of California, Los Angeles (UCLA) activity score, Harris hip score, and RAND-36 were also completed at these intervals.


The Bone & Joint Journal
Vol. 95-B, Issue 8 | Pages 1040 - 1044
1 Aug 2013
Kazi HA Perera JR Gillott E Carroll FA Briggs TWR

We prospectively assessed the efficacy of a ceramic-on-metal (CoM) hip bearing with uncemented acetabular and femoral components in which cobalt­–chrome acetabular liners and alumina ceramic heads were used.

The cohort comprised 94 total hip replacements (THRs) in 83 patients (38 women and 45 men) with a mean age of 58 years (42 to 70). Minimum follow-up was two years. All patients had pre- and post-operative assessment using the Western Ontario and McMaster Universities osteoarthritis index (WOMAC), Oxford hip score and Short-Form 12 scores. All showed a statistically significant improvement from three months post-operatively onwards (all p < 0.001).

After two years whole blood metal ion levels were measured and chromosomal analysis was performed. The levels of all metal ions were elevated except vanadium. Levels of chromium, cobalt, molybdenum and titanium were significantly higher in patients who underwent bilateral THR compared with those undergoing unilateral THR (p < 0.001). Chromosomal analysis demonstrated both structural and aneuploidy mutations. There were significantly more breaks and losses than in the normal population (p < 0.001). There was no significant difference in chromosomal aberration between those undergoing unilateral and bilateral procedures (all analyses p ≥ 0.62).

The use of a CoM THR is effective clinically in the short-term, with no concerns, but the significance of high metal ion levels and chromosomal aberrations in the long-term remains unclear.

Cite this article: Bone Joint J 2013;95-B:1040–44.


The Bone & Joint Journal
Vol. 95-B, Issue 8 | Pages 1052 - 1056
1 Aug 2013
Lampropoulou-Adamidou K Georgiades G Vlamis J Hartofilakidis G

We evaluated the outcome of 41 consecutive Charnley low-friction arthroplasties (LFAs) performed by a single surgeon in 28 patients aged ≤ 35 years at operation between 23 and 36 years previously. There were 20 women and eight men with a mean age of 32 years (23 to 35) at surgery. Two patients (three hips) were lost to follow-up at 12 and 17 years post-operatively, respectively, and one patient (one hip) died at 13 years post-operatively. These patients were excluded from the final evaluation. The survival rate of the acetabular components was 92.7% (95% confidence interval (CI) 88.7 to 96.7) at ten years, 67.1% (95% CI 59.75 to 74.45) at 20 years and 53.2% (95% CI 45.3 to 61.1) at 25 years. For the femoral component the survival was 95.1% (95% CI 91.8 to 98.5) at ten years, 77.1% (95% CI 73.9 to 80.3) at 20 years and 68.2% (95% CI 60.7 to 75.8) at 25 years. The results indicate that the Charnley LFA remains a reasonable choice in the treatment of young patients and can serve for comparison with newer techniques and implants.

Cite this article: Bone Joint J 2013;95-B:1052–6.