Advertisement for orthosearch.org.uk
Results 301 - 307 of 307
Results per page:
The Journal of Bone & Joint Surgery British Volume
Vol. 82-B, Issue 3 | Pages 433 - 434
1 Apr 2000
Fleming P Fitzgerald P Devitt A Rice J Murray P

Compression foot pumps are widely used for the prevention of postoperative venous thrombosis. We tested the efficiency of the pump in ten healthy subjects; the velocity of venous blood flow in the common femoral vein was measured in the horizontal, Trendelenberg (foot-up) and reverse-Trendelenberg (foot-down) positions.

Application of the foot pump produced an increase in the venous velocity in all subjects. The mean increase in the horizontal position was 27.2% and in the Trendelenberg position 15.4%. In the reverse-Trendelenberg position, the foot pump produced a mean increase of 102.8%.

The efficiency of the compression foot pump in increasing venous return is improved by adopting the reverse-Trendelenberg position. This may increase its thromboprophylactic effect.


The Journal of Bone & Joint Surgery British Volume
Vol. 81-B, Issue 6 | Pages 1046 - 1050
1 Nov 1999
Swiontkowski MF Hanel DP Vedder NB Schwappach JR

The current standard recommendation for antibiotic therapy in the management of chronic osteomyelitis is intravenous treatment for six weeks. We have compared this regime with short-term intravenous therapy followed by oral dosage.

A total of 93 patients, with chronic osteomyelitis, underwent single-stage, aggressive surgical debridement and appropriate soft-tissue coverage. Culture-specific intravenous antibiotics were given for five to seven days, followed by oral therapy for six weeks. During surgery, the scar, including the sinus track, was excised en bloc. We used a high-speed, saline-cooled burr to remove necrotic bone, and osseous laser Doppler flowmetry to ensure that the remaining bone was viable. Infected nonunions (Cierny stage-IV osteomyelitis) were stabilised by internal fixation. In 38 patients management of dead space required antibiotic-impregnated polymethylmethacrylate beads, which were exchanged for an autogenous bone graft at six weeks. Free-tissue transfer often facilitated soft-tissue coverage. These 93 patients were compared with 22 consecutive patients treated previously who had the same surgical management, but received culture-specific intravenous antibiotics for six weeks.

Of the 93 patients, 80 healed without further intervention. Of the 31 Cierny-IV lesions, 27 healed without another operation, and four fractures required additional bone grafts. No more wound drainage was needed. Treatment was successful in 91% of patients, regardless of the organism involved. There was no difference in outcome in terms of these variables when the series were compared. We conclude that the long-term administration of intravenous antibiotics is not necessary to achieve a high rate of clinical resolution of wound drainage for adult patients with chronic osteomyelitis.


The Journal of Bone & Joint Surgery British Volume
Vol. 81-B, Issue 6 | Pages 1041 - 1045
1 Nov 1999
Simpson AHRW Cole AS Kenwright J

Distraction osteogenesis is widely used for leg lengthening, but often requires a long period of external fixation which carries risks of pin-track sepsis, malalignment, stiffness of the joint and late fracture of the regenerate.

We present the results of 20 cases in which, in an attempt to reduce the rate of complications, a combination of external fixation and intramedullary nailing was used. The mean gain in length was 4.7 cm (2 to 8.6). The mean time of external fixation was 20 days per centimetre gain in length. All distracted segments healed spontaneously without refracture or malalignment. There were three cases of deep infection, two of which occurred in patients who had had previous open fractures of the bone which was being lengthened. All resolved with appropriate treatment.

This method allows early rehabilitation, with a rapid return of knee movement. There is a lower rate of complications than occurs when external fixation is used on its own. The time of external fixation is shorter than in other methods of leg lengthening. The high risk of infection calls for caution.


The Journal of Bone & Joint Surgery British Volume
Vol. 81-B, Issue 6 | Pages 1035 - 1040
1 Nov 1999
Atkins RM Madhavan P Sudhakar J Whitwell D

The ipsilateral and contralateral fibulae have been used as a vascularised bone graft for loss of tibial bone usually by methods which have involved specialised microvascular techniques to preserve or re-establish the blood supply.

We have developed a method of tibialisation of the fibula using the Ilizarov fixator system, ipsilateral vascularised fibular transport (IVFT), and have used it in five patients with massive loss of tibial bone after treatment of an open fracture, infected nonunion or chronic osteomyelitis. All had successful transport, proximal and distal union, and hypertrophy of the graft without fracture. One developed a squamous-cell carcinoma which ultimately required amputation of the limb.

The advantage of IVFT is that the fibular segment retains its vascularity without the need for microvascular dissection or anastomoses. Superiosteal formation of new bone occurs if the tibial periosteal bed is retained. Other procedures such as corticotomy and lengthening can be carried out concurrently.


The Journal of Bone & Joint Surgery British Volume
Vol. 81-B, Issue 5 | Pages 890 - 892
1 Sep 1999
Rickman M Saleh M Gaines PA Eyres K

Osteotomies are commonly carried out in orthopaedic surgery, particularly in limb reconstruction. Complications are uncommon provided that sufficient care is taken and a sound technique used. We describe three cases of formation of false aneurysm after osteotomy, with acute, delayed and asymptomatic onset. The diagnosis was supported by ultrasound investigation, and confirmed by angiography. Embolisation with coils was a successful method of treatment. We recommend a safe method of osteotomy with good bone exposure and adequate soft-tissue protection.


The Journal of Bone & Joint Surgery British Volume
Vol. 81-B, Issue 5 | Pages 893 - 894
1 Sep 1999
Armstrong PM Ilyas I Pandey R Berendt AR Conlon CP Simpson AHRW

We describe a case of pyoderma gangrenosum which presented with severe wound breakdown after elective hip replacement. The patient was treated successfully with minimal wound debridement and steroids. This diagnosis should always be considered when confronted with an enlarging painful skin lesion which does not grow organisms when cultured and fails to respond to antibiotic therapy, especially if there are similar lesions in other sites. In patients who have a past history of pyoderma gangrenosum, prophylactic steroids may be indicated at the time of surgery or may be required early in the postoperative period.


The Journal of Bone & Joint Surgery British Volume
Vol. 81-B, Issue 5 | Pages 886 - 889
1 Sep 1999
Davis N Curry A Gambhir AK Panigrahi H Walker CRC Wilkins EGL Worsley MA Kay PR

All surgical operations have the potential for contamination, and the equipment used can harbour bacteria. We collected samples from 100 elective primary hip and knee arthroplasties. These showed rates of contamination of 11.4% for the sucker tips, 14.5% for light handles, 9.4% for skin blades and 3.2% for the inside blades used during surgery; 28.7% of gloves used for preparation were also contaminated. Of the samples taken from the collection bags used during hip arthroplasty, 20% grew bacteria, which represents a significant microbial reservoir. Also, 17% of theatre gowns were contaminated at the end of the operation. Contamination was found in 10% of the needles used during closure of the fascia. Overall, 76% of the organisms grown were coagulase-negative staphylococcus. A total of 63% of operations showed contamination in the field of operation. Some changes in practice are suggested. Follow-up for a minimum of two years revealed one deep infection but the organism was not identified as a contaminant. These data provide a baseline for studying the bacteriology of the surgery of revision arthroplasty.