header advert
Results 1 - 58 of 58
Results per page:
Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_10 | Pages 30 - 30
1 Jun 2023
Tissingh E Goodier D Wright J Timms A Campbell M Crook G Calder P
Full Access

Introduction

The FitBone lengthening nail (Orthofix UK) is an intramedullary device licensed for the lengthening of long bones in adults in the UK. It contains a motor powered by electricity transmitted via an induction coil placed underneath the skin. It was developed in Germany two decades ago but uptake in the UK has only started more recently. The aim of this study was to review the first cohort of FitBone lengthening nails in a unit with significant experience of other lengthening nails (including PRECICE and Stryde).

Materials & Methods

Demographic, clinical and radiological data was prospectively collected on all FitBone cases starting in February 2022. Accuracy of lengthening rate, patient satisfaction and implant issues were all considered. Complications and learning points were recorded and discussed by the multidisciplinary team involved in the patients care.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_10 | Pages 23 - 23
1 Jun 2023
Timms A Sironi A Wright J Goodier D Martin L Calder P
Full Access

Introduction

Adjusting an external fixator can be a daunting process for patients. Despite comprehensive training, patients often request supervision for the initial adjustments which may result in a prolonged hospital stay. Following the introduction of telemedicine during the pandemic we believed that this could be utilised to support patients with their fixator adjustments. A quality improvement project was implemented to assess and evaluate a change in practice from existing Face to Face support to a telemedicine format. The aim of the project was to reduce median length of stay (LOS).

Materials & Methods

The telemedicine platform was introduced in our unit from April 2021 with the change in practice. Using the life QI platform, run charts were used to record the numbers of patients whose LOS was 4 days or less. Median LOS was assessed prior to and following introduction of the telemedicine platform. Service user experience with telemedicine as well as overall training and education by the CNS team was sought through on-line questionnaires.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_10 | Pages 31 - 31
1 Jun 2023
Tissingh E Wright J Goodier D Calder P Vris A Iliadis A
Full Access

Introduction

A greater emphasis has been placed on fracture related infection (FRI) orthopaedic practice as a separate entity in recent years. Since the publication of the FRI consensus definition and guidelines, there has been an increase in the published literature on the topic and a move towards considering FRI as separate from general orthopaedic practice and as work that requires a more specialist approach. The aim of this study was to audit current FRI practice in the UK.

Materials & Methods

Orthopaedic practice related to FRI in the UK was audited using a semi-structured questionnaire. Respondents were from a range of institutions, specialties and clinical roles to reflect the multi-disciplinary nature of treating FRI. The online tool SurveyMonkey was used to share the survey at the 2022 annual meeting of the British Limb Reconstruction Society. Twenty-one questions were asked in the following domains: scope of practice, theatre and clinic capacity, availability of the multidisciplinary team, renumeration for work and scope of FRI networks.


Bone & Joint 360
Vol. 11, Issue 5 | Pages 6 - 8
1 Oct 2022
Jamal B Calder P


The Bone & Joint Journal
Vol. 104-B, Issue 2 | Pages 302 - 308
1 Feb 2022
Dala-Ali B Donnan L Masterton G Briggs L Kauiers C O’Sullivan M Calder P Eastwood DM

Aims

Osteofibrous dysplasia (OFD) is a rare benign lesion predominantly affecting the tibia in children. Its potential link to adamantinoma has influenced management. This international case series reviews the presentation of OFD and management approaches to improve our understanding of OFD.

Methods

A retrospective review at three paediatric tertiary centres identified 101 cases of tibial OFD in 99 patients. The clinical records, radiological images, and histology were analyzed.


Bone & Joint Open
Vol. 2, Issue 9 | Pages 705 - 709
1 Sep 2021
Wright J Timms A Fugazzotto S Goodier D Calder P

Aims

Patients undergoing limb reconstruction surgery often face a challenging and lengthy process to complete their treatment journey. The majority of existing outcome measures do not adequately capture the patient-reported outcomes relevant to this patient group in a single measure. Following a previous systematic review, the Stanmore Limb Reconstruction Score (SLRS) was designed with the intent to address this need for an effective instrument to measure patient-reported outcomes in limb reconstruction patients. We aim to assess the face validity of this score in a pilot study.

Methods

The SLRS was designed following structured interviews with several groups including patients who have undergone limb reconstruction surgery, limb reconstruction surgeons, specialist nurses, and physiotherapists. This has subsequently undergone further adjustment for language and clarity. The score was then trialled on ten patients who had undergone limb reconstruction surgery, with subsequent structured questioning to understand the perceived suitability of the score.


Bone & Joint Open
Vol. 2, Issue 8 | Pages 599 - 610
1 Aug 2021
Hothi H Bergiers S Henckel J Iliadis AD Goodier WD Wright J Skinner J Calder P Hart AJ

Aims

The aim of this study was to present the first retrieval analysis findings of PRECICE STRYDE intermedullary nails removed from patients, providing useful information in the post-market surveillance of these recently introduced devices.

Methods

We collected ten nails removed from six patients, together with patient clinical data and plain radiograph imaging. We performed macro- and microscopic analysis of all surfaces and graded the presence of corrosion using validated semiquantitative scoring methods. We determined the elemental composition of surface debris using energy dispersive x-ray spectroscopy (EDS) and used metrology analysis to characterize the surface adjacent to the extendable junctions.


The Bone & Joint Journal
Vol. 103-B, Issue 6 | Pages 1168 - 1172
1 Jun 2021
Iliadis AD Wright J Stoddart MT Goodier WD Calder P

Aims

The STRYDE nail is an evolution of the PRECICE Intramedullary Limb Lengthening System, with unique features regarding its composition. It is designed for load bearing throughout treatment in order to improve patient experience and outcomes and allow for simultaneous bilateral lower limb lengthening. The literature published to date is limited regarding outcomes and potential problems. We report on our early experience and raise awareness for the potential of adverse effects from this device.

Methods

This is a retrospective review of prospective data collected on all patients treated in our institution using this implant. We report the demographics, nail accuracy, reliability, consolidation index, and cases where concerning clinical and radiological findings were encountered. There were 14 STRYDE nails implanted in nine patients (three male and six female) between June 2019 and September 2020. Mean age at surgery was 33 years (14 to 65). Five patients underwent bilateral lengthening (two femoral and three tibial) and four patients unilateral femoral lengthening for multiple aetiologies.


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_6 | Pages 38 - 38
1 May 2021
Iliadis A Timms A Fugazzotto S Edel P Wright J Goodier D Britten S Calder P
Full Access

Introduction

The use of intramedullary lengthening devices is becoming increasingly popular. There are no published data regarding the incidence of venous thromboembolism following intramedullary lengthening and no reports or guidance for current practices on use of thromboprophylaxis. Following a case of post-operative deep vein thrombosis in our institution, we felt that it is important to assess best practice. We conducted this survey to collect data that would describe current practice and help guide consensus for treatment.

Materials and Methods

We have identified surgeons across the UK that perform intramedullary lengthening through the British Limb Reconstruction Society membership and a Precise Users database. Surgeons were contacted and asked to respond to an online survey (SurveyMonkey - SVMK Inc.). Responses to thromboprophylaxis regimes employed in their practice and cases of venous thromboembolism were collated.


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_6 | Pages 4 - 4
1 May 2021
Iliadis A Wright J Stoddart M Goodier D Calder P
Full Access

Introduction

The STRYDE nail is an evolution of the PRECICE Intramedullary Limb Lengthening System, with unique features regarding its composition. It is designed for load bearing throughout treatment in order to improve patient experience and outcomes and allow for simultaneous bilateral lower limb lengthening. The literature published to date is limited with regards to both outcomes and potential issues. In this paper we report on our early experience and raise awareness for the potential of adverse effects from this device.

Materials and Methods

This is a review of all patients treated in our institution using this implant. Data were prospectively recorded. We report on demographics, nail accuracy, reliability, consolidation index and cases where concerning clinical and radiological findings were encountered.


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_6 | Pages 41 - 41
1 May 2021
Wright J Timms A Fugazzotto S O'Sullivan C Goodier D Calder P
Full Access

Introduction

Patients undergoing limb reconstruction surgery often face a challenging and often lengthy process to complete their treatment journey. The majority of existing outcome measures do not adequately capture the patient reported outcomes relevant to this patient group in a single measure. Following a previous systematic review, the Stanmore Limb Reconstruction Score (SLRS) was designed with the intent to address this need for an effective instrument to measure patient reported outcomes in limb reconstruction patients.

Materials and Methods

The SLRS was designed following the use of structured interviews with a group of patients who have undergone limb reconstruction surgery, limb reconstruction surgeons, specialist nurses and physiotherapists. This has undergone further adjustment for language and clarity. The score was then trialled on 10 patients who have been through the process of limb reconstruction surgery, with subsequent structured questioning to understand the perceived suitability.


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_6 | Pages 25 - 25
1 May 2021
Stoddart M Elsheikh A Wright J Goodier D Calder P
Full Access

Introduction

Pixel Value Ratio (PVR) is a radiographic measure of the relative density of the regenerate to the adjacent bone. This has been reported as an objective criterion for regenerate healing and a guide for when to allow full weight bearing (FWB) in lengthening with intramedullary telescopic nails. The threshold for which magnitude of PVR is adequate to allow bearing full weight is not yet agreed. The aim of this study was to identify from our cohort of adult limb lengthening patients the time to FWB following lengthening, the PVR at this point, and how this compared with the recommended values in the literature.

Materials and Methods

A retrospective database review identified 30 adult patients treated with the PRECICE femoral nail by two senior authors. Time from completion of lengthening to instruction to fully weight bear was noted. The PVR was calculated for each cortex on plain radiographs taken at each postoperative visit following completion of lengthening. Significance was set at p <0.05.


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_6 | Pages 52 - 52
1 May 2021
Merchant R Tolk J Ayub A Hashemi-Nejad A Eastwood D Tennant S Calder P Wright J Khan T
Full Access

Introduction

Leg length discrepancy (LLD) in patients with unilateral developmental dysplasia of the hip (DDH) can be problematic for both patients and surgeons. Patients can acquire gait asymmetry, back pain, and arthritis. Surgical considerations include timing of correction and arthroplasty planning. This study audits standing long leg films performed at skeletal maturity in our patients. The aim of this study is to identify if surgical procedure or AVN type could predict the odds of needing an LLD Intervention (LLDI) and influence our surveillance.

Materials and Methods

Hospital database was searched for all patients diagnosed with DDH. Inclusion criteria were patients with appropriately performed long leg films at skeletal maturity. Exclusion criteria were patients with non DDH pathology, skeletally immature and inadequate radiographs. All data was tabulated in excel and SPSS was used for analysis. Traumacad was used for measurements and AVN and radiologic outcome grades were independently classified in duplicate.


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_6 | Pages 42 - 42
1 May 2021
Iliadis A Bebja R Wang K Moazen M Wright J Calder P Goodier D
Full Access

Introduction

Ring breakage is a rare but significant complication requiring revision surgery and prolonging the course of treatment. We have encountered three cases with Taylor Spatial Frames (TSF) with breakage at the half ring junction of the distal ring. This experimental study examines the strains produced at different locations on the distal ring during loading and the effects of altering the construct in order to develop techniques to minimise the risk of breakage.

Materials and Methods

We mounted different TSF constructs on tibia sawbone models. Construct 1 reproducing the configuration of cases where failure was seen, Construct 2 with different wire and half pin configuration and construct 3 with the distal ring rotated 60 degrees. Strain Gauges were attached to different locations and measurements were collected during loading. Statistical analysis was subsequently performed.


Bone & Joint Open
Vol. 1, Issue 6 | Pages 287 - 292
19 Jun 2020
Iliadis AD Eastwood DM Bayliss L Cooper M Gibson A Hargunani R Calder P

Introduction

In response to the COVID-19 pandemic, there was a rapidly implemented restructuring of UK healthcare services. The The Royal National Orthopaedic Hospital, Stanmore, became a central hub for the provision of trauma services for North Central/East London (NCEL) while providing a musculoskeletal tumour service for the south of England, the Midlands, and Wales and an urgent spinal service for London. This study reviews our paediatric practice over this period in order to share our experience and lessons learned. Our hospital admission pathways are described and the safety of surgical and interventional radiological procedures performed under general anaesthesia (GA) with regards to COVID-19 in a paediatric population are evaluated.

Methods

All paediatric patients (≤ 16 years) treated in our institution during the six-week peak period of the pandemic were included. Prospective data for all paediatric trauma and urgent elective admissions and retrospective data for all sarcoma admissions were collected. Telephone interviews were conducted with all patients and families to assess COVID-19 related morbidity at 14 days post-discharge.


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_8 | Pages 5 - 5
1 May 2018
Calder P Koroma P Wright J Goodier D Taylor S Blunn G Moazen M
Full Access

Aim

To quantify the micro-motion at the fracture gap in a tibial fracture model stabilised with an external fixator.

Method

A surrogate model of a tibia and a cadaver leg were fractured and stabilised using a two-ring hexapod external fixator. They were tested initially under static loading and then subjected to vibration.


The Bone & Joint Journal
Vol. 100-B, Issue 5 | Pages 634 - 639
1 May 2018
Davda K Heidari N Calder P Goodier D

Aims

The management of a significant bony defect following excision of a diaphyseal atrophic femoral nonunion remains a challenge. We present the outcomes using a combined technique of acute femoral shortening, stabilized with a long retrograde intramedullary nail, accompanied by bifocal osteotomy compression and distraction osteogenesis with a temporary monolateral fixator.

Patients and Methods

Eight men and two women underwent the ‘rail and nail’ technique between 2008 and 2016. Proximal locking of the nail and removal of the external fixator was undertaken once the length of the femur had been restored and prior to full consolidation of the regenerate.


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_8 | Pages 4 - 4
1 May 2018
Timms A Roskrow T Doyle H Edel P Fugazzotto S Goodier W Calder P
Full Access

Introduction

Muscle stiffness and joint contractures are common complications of limb lengthening. Authors have demonstrated less permanent soft tissue complications with intramedullary lengthening than external fixation. Our aim was to evaluate the joint response following intramedullary femoral lengthening and need for physiotherapy and alteration to rate/rhythm of lengthening.

Method

A retrospective review of documentation for all femoral Precice nails in our centre inserted between 2012 and 2017. This involved 98 nails (68 antegrade, 30 retrograde) in 88 patients (59 males, 29 females) with a mean age of 32 years (range 12–69 yrs). We excluded cases where there was no documentation regarding Range of Movement (ROM). Bilateral lengthenings were recorded as separate cases. This left 50 antegrade, 16 retrograde cases with hip ROM data and 55 antegrade, 26 retrograde cases with Knee ROM data.


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_8 | Pages 29 - 29
1 May 2018
Wright J Hill RA Eastwood DM Hashemi-Nejad A Calder P Tennant S
Full Access

Purpose

To review the natural history of posteromedial bowing of the tibia and the outcome of limb reconstruction in this condition.

Patients and Methods

38 patients with posteromedial bowing of the tibia presenting between 2000–2016 were identified. Mean follow up from presentation was 78 months. Seventeen patients underwent lengthening and deformity correction surgery, whilst 3 further patients are awaiting lengthening and deformity correction procedures.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_13 | Pages 1 - 1
1 Jun 2017
Panagiotopoulou V Davda K Hothi H Henckel J Cerquiglini A Goodier W Skinner J Hart A Calder P
Full Access

Introduction

The Precice nail is the latest intramedullary lengthening nail with excellent early outcomes. Implant complications have led to modification of the nail design. The aim of this study was to perform a retrieval study of Precice nails following lower limb lengthening. To assess macroscopic and microscopic changes to the implants and assess differences following design modification, with identification of potential surgical, implant and patient risk factors.

Method

15 nails were retrieved from 13 patients following lower limb lengthening. Macroscopic and microscopic surface damage to the nails were identified. Further analysis included radiology and micro-CT prior to sectioning. The internal mechanism was then analysed with Scanning Electron Microscopy and Energy Dispersive X-ray Spectroscopy to identify corrosion.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_13 | Pages 4 - 4
1 Jun 2017
Davda K Wright S Heidari N Calder P Goodier W
Full Access

Introduction

The management of a significant bone defect following excision of a diaphyseal atrophic femoral non-union remains a challenge. Traditional bone transport techniques require prolonged use of an external fixator with associated complications. We present our clinical outcomes using a combined technique of acute femoral shortening, stabilised with a deliberately long retrograde intramedullary nail, accompanied by bifocal osteotomy compression and distraction osteogenesis to restore segment length utilising a temporary monolateral fixator.

Method

9 patients underwent the ‘rail and nail’ technique for the management of femoral non-union. Distraction osteogenesis was commenced on the 6th post-operative day. Proximal locking of the nail and removal of the external fixator was performed approximately one month after length had been restored. Full weight bearing and joint rehabilitation was encouraged throughout. Consolidation was defined by the appearance of 3 from 4 cortices of regenerate on radiographs.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_13 | Pages 9 - 9
1 Jun 2017
Wright J Calder P
Full Access

Background

Severe infantile Blount's disease can result in a multiplanar deformity of the proximal tibia with both intra-articular and metaphyseal components. Correction can represent a significant surgical challenge. We describe our results using the Taylor spatial frame for acute tibial hemiplateau elevation combined with gradual metaphyseal correction in patients with severe infantile blounts with an associated physeal bony bar.

Methods

Eight patients (10 knees) underwent tibial hemiplateau elevation and metaphyseal correction with use of the Taylor Spatial Frame between 2012–2016. We undertook a retrospective case note and radiographic review of all patients to assess clinical and radiographic outcomes. Mean age at the time of surgery of was 11.7 years and mean length of follow up was 16.8 months.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_11 | Pages 7 - 7
1 Jun 2017
Calder P Shaw S Roberts A Tennant S Sedki I Hanspal R Eastwood D
Full Access

Purpose

This study compares outcomes in patients with complete congenital fibula absence, associated with severe lower limb deformity, treated with an amputation protocol to those using an extension prosthesis.

Method

32 patients were identified. 9 patients (2M: 7F, median age at presentation of 22 yrs) utilized an extension prosthesis. 23 patients (16M: 7F, median age at presentation of 10 months) underwent 25 amputations during childhood: only two underwent tibial kyphus correction to facilitate prosthetic wear.

Mobility was assessed using the SIGAM and K scores. Quality of life was assessed using the PedsQL inventory questionnaire; pain by a verbal severity score. Patients undergoing amputation were further subdivided by age, below and above 2 yrs at the time of surgery.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_13 | Pages 8 - 8
1 Jun 2017
Calder P Shaw S Roberts A Tennant S Sedki I Hanspal R Eastwood D
Full Access

Purpose

This study compares outcomes in patients with complete congenital fibula absence treated with an amputation protocol to those using an extension prosthesis.

Introduction

Complete fibula absence presents with significant lower limb deformity. Parental counselling regarding management is paramount in achieving the optimum functional outcome. Amputation offers a single surgical event with minimal complications and potential excellent functional outcome.


The Bone & Joint Journal
Vol. 98-B, Issue 11 | Pages 1548 - 1553
1 Nov 2016
Tennant SJ Eastwood DM Calder P Hashemi-Nejad A Catterall A

Aims

Our aim was to assess the effectiveness of a protocol involving a standardised closed reduction for the treatment of children with developmental dysplasia of the hip (DDH) in maintaining reduction and to report the mid-term results.

Methods

A total of 133 hips in 120 children aged less than two years who underwent closed reduction, with a minimum follow-up of five years or until subsequent surgery, were included in the study. The protocol defines the criteria for an acceptable reduction and the indications for a concomitant soft-tissue release. All children were immobilised in a short- leg cast for three months. Arthrograms were undertaken at the time of closed reduction and six weeks later. Follow-up radiographs were taken at six months and one, two and five years later and at the latest follow-up. The Tönnis grade, acetabular index, Severin grade and signs of osteonecrosis were recorded.


The Bone & Joint Journal
Vol. 98-B, Issue 10 | Pages 1382 - 1388
1 Oct 2016
Laubscher M Mitchell C Timms A Goodier D Calder P

Aims

Patients undergoing femoral lengthening by external fixation tolerate treatment less well when compared to tibial lengthening. Lengthening of the femur with an intramedullary device may have advantages.

Patients and Methods

We reviewed all cases of simple femoral lengthening performed at our unit from 2009 to 2014. Cases of nonunions, concurrent deformities, congenital limb deficiencies and lengthening with an unstable hip were excluded, leaving 33 cases (in 22 patients; 11 patients had bilateral procedures) for review. Healing index, implant tolerance and complications were compared.


Orthopaedic Proceedings
Vol. 97-B, Issue SUPP_5 | Pages 5 - 5
1 May 2015
Peek A Timms A Wartemberg G Chin K Calder P Goodier D
Full Access

Several low energy osteotomy techniques are described in the literature but there is limited evidence comparing healing indices. We present a retrospective review of two techniques to evaluate an optimum method.

Method:

Two cohorts of patients underwent osteotomy of the tibia using a Gigli saw (n=15) or DeBastiani corticotomy (n=12) technique. Indications for surgery included limb lengthening and bone transport for defect reconstruction with a minimal distraction of 2 cm. The patient radiographs were anonymised and the regenerate assessed by the two senior authors who were blinded to the osteotomy type. Bone quality was recorded along the anterior, posterior, medial and lateral cortices, graded 1–5 from absent to full consolidation over time in frame. The time to 3 cortices healed/regenerate length was calculated. The time to consolidation of the anterior, posterior, medial and lateral cortices were compared.

Results:

The mean 3 cortices index in the Gigli group was 2.0 months/cm and in the DeBastiani group 1.8 months/cm, This was not a significant difference. In both groups anterior bone formation was slower, and in 50% and 33% of the Gigli and DeBastiani groups respectively the anterior cortex did not fully heal by the time of frame removal.


Orthopaedic Proceedings
Vol. 97-B, Issue SUPP_5 | Pages 13 - 13
1 May 2015
Mitchell C Timms A Laubscher M Goodier D Calder P
Full Access

Background:

The Exogen Ultrasound Device is licensed for fracture non-union under NICE guideline MTG-12. Reimbursement is offered if there is no fracture union after 250 days of treatment as per manufacturer guidelines. Quoted healing rates vary between 62% and 100%: we compare our results to these.

Method:

A retrospective audit of all patients who received Exogen for long bone non-union was undertaken. The indication, duration of treatment, fracture outcome and compliance with the recommended treatment pathway were recorded.


Orthopaedic Proceedings
Vol. 97-B, Issue SUPP_5 | Pages 1 - 1
1 May 2015
Laubscher M Mitchell C Timms A Goodier D Calder P
Full Access

Background:

External fixators are not as well tolerated around the femur when compared to the tibia. Lengthening with an intramedullary device is therefore attractive.

Method:

We reviewed all cases of femoral lengthening performed at our unit from 2007 to 2014. Cases of non-unions, concurrent deformities, congenital limb deficiencies and lengthening with an unstable hip were excluded. This left 33 cases for review. Healing index, implant tolerance and complications were compared.


Orthopaedic Proceedings
Vol. 97-B, Issue SUPP_5 | Pages 15 - 15
1 May 2015
Laubscher M El-Tawil S Ibrahim I Mitchell C Smitham P Chen P Goodier D Gorjon J Richards R Taylor S Calder P
Full Access

Background:

Little is known about the forces carried by the Taylor Spatial Frame (TSF) hexapod fixator. Our aim was to measure the TSF resultant force and how this changed during the consolidation phase.

Method:

Five patients undergoing correction of tibial deformities were recruited. Measurements were taken at 2, 4, 8 and 12 weeks post-correction during various activities. Instrumented struts incorporating strain gauges measuring axial force were temporarily used each time. Strut forces and lengths were used to determine frame kinetics. The resultant axial fixator forces and moments were calculated relative to sitting. Ground reaction forces (GRF) were measured using the treadmill force plates.


Orthopaedic Proceedings
Vol. 97-B, Issue SUPP_5 | Pages 4 - 4
1 May 2015
Laubscher M Mitchell C Timms A Goodier D Calder P
Full Access

Background:

Leg length discrepancy related to absence of the femoral head with proximal migration of the femur presents a treatment dilemma. Late sequelae of neonatal hip sepsis and chronic hip dislocation due to developmental dysplasia are the most common causes. Traditional teaching dictates that the hip is stabilised prior to limb lengthening. Reconstructive options alter the shape of the proximal femur which complicates future surgery.

Methods:

We retrospectively reviewed 3 cases of femoral lengthening with an ‘unstable’ hip without prior stabilization. The aetiology was neonatal hip sepsis in 2 cases and chronic hip dislocation due to developmental dysplasia in 1 case. Lengthening was performed with the use of a retrograde Precice lengthening nail.


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_10 | Pages 22 - 22
1 Jul 2014
Ibrahim I Timms A Chasseaud M Goodier D Calder P
Full Access

Pin site care in external fixation remains a major challenge. The ideal dressing regime still remains controversial as does the type of dressing. We present an audit following the use of a sponge compression dressing in comparison to previously used sterile gauze.

All pins and wires were inserted using a standardised technique. Dressings were applied during surgery to prevent haematoma formation.

The new sponge dressing was applied to the wire or half-pin sites and compressed to the skin by either pierced tubing over the wire or clips at the end of the procedure. Dressings were changed weekly unless the pin sites were discharging serous fluid or frankly infected, when they were changed as required.

The pin sites were evaluated for evidence of infection or irritation using the good, bad or ugly grading system. Each evaluation was performed by two of the authors on two separate occasions to assess the inter- and intra-observer error. The results were compared to those previously reported using sterile gauze as the pin site dressing.

1035 pin sites were assessed. 985 pin sites were graded as “good” (95.2%), 49 “bad” (4.7%) and 1 “ugly”. The kappa values demonstrated excellent inter- and intra-observer correlation, 0.892 and 0.905 respectively.

The previous study using gauze reported 600 pin sites with 514 graded “good” (85.7%), 80 “bad” (13.3%) and 6 “ugly” (1%).

The use of compression sponge dressing appears to reduce the rate of pin site irritation and infection. Further anecdotal evidence by patients who have undergone surgical treatment using both techniques demonstrated a preference for the sponge dressings due to ease of dressing change and general comfort once applied. We therefore would recommend this type of dressing in the use of external fixation.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_23 | Pages 13 - 13
1 May 2013
Barker A Smitham P Scarsbrook C Calder P
Full Access

A statement of the purposes of the study

This study examined the stability of two different hexapod frames at increasing strut angles and the possible use of an additional strut to aid stability.

Introduction

Hexapod frames have certain advantages over standard circular frames, however disadvantages include a rattle and instability at some strut angles. This could be particularly important when larger diameter rings are used over a shorter distance resulting in lower ring strut angles such as in the femur.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_23 | Pages 11 - 11
1 May 2013
Calder P McGrath A Chasseaud M Timms A Goodier W
Full Access

We present the results of a new non-invasive lengthening nail enabling accurate control of the lengthening process and joint rehabilitation.

Introduction

The use of intramedullary lengthening nails have gained popularity as they reduce common complications associated with external fixators, including infection, joint stiffness, bone regenerate deformity, late fracture and patient implant acceptance. Current nails however are associated with complications including implant breakage, mechanical failure, runaway nail and requiring MUA to restart or obtain segment lengthening. The Precice nail incorporates magnet technology with a hand held device allowing non-invasive lengthening. The nail is also reversible allowing shortening if required. Physiotherapy can continue throughout treatment to maintain joint range of motion without concern of uncontrolled nail runaway. The lengthening is axial reducing shear/torsional forces on the regenerate.

Method

The lengthening of 4 femora was undertaken in 3 patients, mean age 34 yrs for post-traumatic shortening and short stature. A standard technique included an Ilizarov corticotomy followed by a 6 day latent period. Patients were mobilised partial weight bearing and knee range of motion maintained. The femora were lengthened one third of a millimetre three times per day. Radiographic and clinical review was performed every 2 weeks.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_23 | Pages 1 - 1
1 May 2013
Welck MJ Calder P Eastwood D
Full Access

Purpose of Study

To see if the addition of a locking plate to FD rod fixation of osteogenesis imperfecta confers extra strength and allows earlier mobilisation.

Introduction

Osteogenesis imperfecta is a heterogeneous group of disorders with congenital osseous fragility. The goal of surgery is to minimise the incidence of fracture and correct deformity. The concept of multilevel osteotomies and intramedullary fixation with a non-extendable nail was popularised by Sofield and Millar in 1959. The Bailey Dubow telescoping nail was introduced in 1963. The Fassier-Duval (FD) telescoping nail is a more recent design inserted via smaller incisions, in conjunction with percutaneous osteotomies. However there are still problems. Often the medullary canal may be too narrow to harbour a nail of adequate size for the body. Furthermore they do not give significant rotational control, which is compounded by the elasticity of the soft tissues.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_16 | Pages 70 - 70
1 Apr 2013
Smitham P Scarsbrook C Barker A Calder P
Full Access

Introduction

Fracture healing is governed by biological and mechanical factors. Circular frames are one method to fix fractures. Recently, the number of frame designs that are available has increased and these different designs may have different effects on the mechanical environment created. The senior author has been concerned by the stability of the construction when a short frame is used. This study examined the stability of different frames and the possible use of additional 7th struts to aid stability.

Method

The frame configuration was modified with increasing strut angles from 15° − 70°. Each frame was cyclically tested in compression to 200N. The Taylor Spatial Frame was retested with the addition of a seventh strut.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_6 | Pages 3 - 3
1 Feb 2013
Wright J Randhawa S Gooding C Lowery S Calder P
Full Access

Identification of the paediatric orthopaedic patient at high risk of venous thromboembolism (VTE) can allow a targeted approach to thromboprophylaxis. There is currently no national consensus on the correct method of risk assessment in this patient group. The Royal National Orthopaedic Hospital has developed a guideline using the evidence available to allow stratification of risk for the paediatric orthopaedic patient.

A list of departments offering specialist paediatric orthopaedic surgery was obtained from the member list of the British Society of Paediatric Orthopaedic Surgeons (BSCOS). These hospitals were contacted via telephone interview to determine if they have a specific guideline or risk assessment proforma for paediatric VTE risk.

A total of 74 hospitals were identified with a specialist paediatric orthopaedic practice in the United Kingdom. A response rate was gained from 100% of these hospitals. Only 3/74 of these hospitals had a guideline or protocol in place for the formal assessment of VTE risk in the paediatric patient (Royal National Orthopaedic Hospital, Stanmore; Sheffield Children's Hospital; Barts & the London NHS Trust). All three hospitals were able to provide details of their guideline. Both the RNOH and Barts & the London commented that their guideline was based on that of the Sheffield group, with adaptations for their own requirements.

The majority of hospitals in the UK with a paediatric orthopaedic interest do not have guidance available for the management of VTE risk. Presented here is the outcome of using the limited evidence available, in combination with expert opinion, to develop a guideline suitable for the requirements of a paediatric unit in an orthopaedic hospital. This may be of benefit to other units producing their own guidelines, producing thought and discussion as to the specific requirements of paediatric patients undergoing orthopaedic procedures.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_7 | Pages 2 - 2
1 Feb 2013
Roberts D Panagiotidou A Calder P
Full Access

Purpose

To investigate the incidence of deep vein thrombosis (DVT) and pulmonary embolism (PE) with external fixator use and to help establish whether current guidelines are appropriate.

Methods

Case notes of individuals undergoing external fixator application by the senior author (PC) from March 2005 to June 2011 were examined. In this period 207 individuals underwent 255 primary applications of Ilizarov, Taylor Spatial Frame (TSF) or monolateral fixator. Fixators applied were 173 tibial, 63 femoral and 19 to other bones. Records were obtained for 182 individuals (88%), representing 214 operations (84%).


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_6 | Pages 17 - 17
1 Feb 2013
Stöhr K Randhawa S Calder P Tennant S Hashemi-Nejad A Eastwood D
Full Access

Purpose of study

We hypothesised that Vitamin D deficiency could be related to SUFE in children without endocrinological abnormalities. We therefore sought to examine prevalence and severity of Vitamin D insufficiency in a cross-section of SUFE patients.

Methods

Vitamin D levels were tested for at time of hospital admission for operative treatment of SUFE. Seven patients, between the months of July 2011 to November 2011, presented to our institution. All were chronic, stable slips treated with in-situ screw fixation. All patients presented in the summer months and were operated on within 3 weeks of presentation.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_2 | Pages 6 - 6
1 Jan 2013
Rudge B Jennings R Calder P
Full Access

Introduction

Lower limb mal-alignment as a result of fracture malunion can result in knee degenerative arthritis or predispose to early arthroplasty failure due to the altered mechanical axis. The choice of corrective osteotomy is often determined by potential complications. Opening wedge osteotomy is associated with poor bone healing especially in adult diaphyseal bone. Distraction osteogenesis enables gradual deformity correction with the gap filled by regenerate bone. Bone formation however is formed less favourably in the diaphysis and metaphyseal osteotomy is advised. We present a consecutive series of adult tibial diaphyseal correction using the Taylor Spatial Frame utilising the method of distraction osteogenesis.

Method

15 adults, 11 male and 3 female, underwent tibial deformity correction. A mid diaphyseal osteotomy was made using minimal soft tissue dissection and an osteotome. The site was determined by the centre of rotation of angulation (CORA). After a 6 day latency period distraction was undertaken by the Taylor Spatial Frame. Patients were encouraged to fully weight bear throughout the treatment process. Following regenerate consolidation the frame was removed and a below knee weight bearing cast applied for 4 weeks.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_1 | Pages 222 - 222
1 Jan 2013
Roberts D Panagiotidou A Calder P
Full Access

Introduction

No published work exists regarding deep vein thrombosis (DVT) and pulmonary embolism (PE) incidence with the elective use of external fixators. The aim of this work was to establish the rate of DVT and PE in such cases to help inform whether thromboprophylaxis guided by risk factors is adequate or if a more aggressive approach is required.

Patients and methods

Information from a prospectively maintained electronic database and case notes were examined for consecutive patients from March 2005 to June 2011. Occurrence of DVT and PE, detected by ultrasound or CT angiogram, were recorded. Risk factors for thromboembolism, age, weight, height, surgical indications, type of surgery and operative time were recorded. As recommended by the National Institute for Health and Clinical Excellence (NICE) thromboprophylaxis use is guided by risks of thromboembolism and bleeding. For adults and older adolescent patients contralateral leg compression stockings and an intraoperative calf pump were used. Mobilisation began the morning after surgery and the majority of cases permitted to bear weight fully.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXIX | Pages 42 - 42
1 Sep 2012
Smitham P Khan W Hazlerigg A Bajaj S McCarthy I Calder P
Full Access

Introduction

Patients undergoing limb reconstruction with the Taylor Spatial Frame (TSF) often perceive that their frame is loose due to the rattle they hear when mobilising. Our aim was to determine how much and where this movement is in the various frame/bone constructs currently on the market.

Method

Using standard tibial saw bones three frames (TSF, Ilizarov and Hexapod) were made in an identical fashion. Constructs were cyclically loaded 4 times to 200 N in tension and compression using the Instron MTS. This was repeated three times. A seventh strut was also placed in the TSF construct and the tests repeated. Bones were then removed and the tests repeated for the frames alone.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXIX | Pages 45 - 45
1 Sep 2012
Bajaj S Patel S Eastwood D Calder P
Full Access

Aim

To evaluate the results and complications of bone transport in the treatment of massive tibial bone defects, using the Ilizarov method.

Methods

15 patients underwent bone transport using the Ilizarov technique to treat massive tibial bone defects. The average age of the patients was 8.7 years (3–24 years) and the mean bone defect was 10.8 cms. Following a latent period of 1 week, distraction of the transport doughnut was commenced at 1mm/24 hours in 4 quarterly turns. A docking procedure was performed in 7 cases which involved freshening of the bone ends and autogenous bone grafting from the iliac crest. Following docking the fixator was removed once the regenerate had consolidated.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXIV | Pages 4 - 4
1 May 2012
de Gheldere A Hashemi-Nejad A Calder P Tennant S Eastwood D
Full Access

Purpose

To document the success rate of closed reduction and soft tissue release in the treatment of bilateral true dislocation in developmental dysplasia of the hip (DDH).

Methods

Case-note review of 22 children (44 hips) with idiopathic bilateral hip dislocation referred to a tertiary centre before walking age. The management protocol was as follows:

Examination under general anaesthesia, arthrogram, closed reduction and appropriate soft tissue release (adductors/psoas), application of a ‘frog’ cast.

CT scan at 2 weeks to confirm reduction.

Change of cast and arthrogram at 6 weeks to confirm improving position and stability.

Cast removal at 12 weeks, and application of an abduction brace for 6 weeks.

Treatment failure could occur on day 1 (failure of reduction), at week 2 (failure to maintain reduction), at week 6, or after cast removal.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_VII | Pages 7 - 7
1 Mar 2012
Calder P Tennant S Hashemi-Nejad A Catterall A Eastwood D
Full Access

Purpose

To investigate the effect of soft tissue release (STR) and the length of postoperative immobilisation on the long term outcomes of closed reduction (CR) of the hip for developmental dysplasia of the hip.

Materials

77 hips (72 patients) who had undergone closed reduction (CR) between 1977-2005 were studied retrospectively to review their outcome (Severin grade), identify the reasons for failure and to assess factors associated with residual dysplasia. Particular attention was paid to the use of a STR at the time of CR (to improve initial hip stability) and the duration of postoperative immobilisation.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_VII | Pages 10 - 10
1 Mar 2012
de Gheldere A Calder P Bradish C Eastwood D
Full Access

Purpose

To document the incidence and nature of complications associated with hemiepiphysiodesis using a screw and plate device (8-plate, Orthofix).

Methods

We reviewed case notes and radiographs of 71 children (130 segments) with lower limb deformities treated with temporary hemiepiphyseal arrest using the 8-plate. 96% of deformities were in the coronal plane, 4% sagittal. 72% of coronal deformities demonstrated valgus malalignment. We defined three types of complications:

early (perioperative) complications eg infection and/or wound breakdown, bleeding, neurological impairment

implant related complications such as soft tissue irritation, plate breakage or migration,

complications involving the growth plate including rebound deformity, early physeal closure or iatrogenic deformity.

Complications were related to variables of patient age, gender, diagnosis, location of deformity and associated surgery.


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 1 | Pages 144 - 144
1 Jan 2007
Calder P


Orthopaedic Proceedings
Vol. 88-B, Issue SUPP_III | Pages 436 - 436
1 Oct 2006
Tennant S Tingerides C Calder P Hashemi-Nejad A Eastwood D
Full Access

Introduction: Percutaneous epiphyseodesis is a simple method of achieving leg length equality in cases of minor leg length discrepancy, however few studies document its effectiveness. A retrospective study was undertaken to assess this.

Materials and methods: Patient notes and radiographs were reviewed. The growth remaining method was used to estimate timing. Percutaneous epiphyseodesis was performed with a drill and curette under radiological guidance.

Results: A total of 24 skeletally mature patients with a mean preoperative leg length discrepancy (LLD) of 2.8cm were identified. Skeletal age was significantly different from chronological age in 5 of 11 cases where it had been performed. In all patients, there was radiographic evidence of physeal closure soon after epiphyseodesis. At skeletal maturity, 14 patients have a LLD of 0–1cm and are considered to have a satisfactory outcome. 10 patients have a LLD> 2cms. In 6 of these, either presentation was too late or the amount of discrepancy too large for complete correction to be expected. In the other 4, skeletal age assessment may have been useful in 3, and in one additional case of overgrowth of the short limb prior to maturity. A successful outome was more likely when skeletal age assessment had been used (82% versus 57%). Of the 18 cases where there was sufficient time for a full correction to be achieved, the overall success rate was 72%. There were no significant clinical or radiological complications.

Conclusions:

Percutaneous drill epiphyseodesis is an effective method of achieving physeal ablation with no significant complications.

While the growth remaining method is a crude estimate of the timing of epiphyseodesis, it was accurate in the majority of cases in this small series.

The determination of skeletal age was found to be a useful adjunct to management in a small proportion of cases.


Orthopaedic Proceedings
Vol. 88-B, Issue SUPP_I | Pages 170 - 171
1 Mar 2006
Hawkins R Calder P Goodier D
Full Access

The stability of an external ring fixator using trans-osseous wires is determined by the number of wires per ring, their tension and their configuration. Ideally a crossing angle of 90° in the centre of the bone provides the greatest stability. This is however rarely possible due to the restrictions imposed by safe anatomical corridors. The Taylor Spatial Frame is a hexapod structure which relies on 6 connecting struts attached to fixed tabs on the ring; the Ilizarov system allows connecting rods to be placed in any available spaces.

The aim of this study was to identify differences in wire placement using the TSF compared with the standard Ilizarov ring.

Method: Cross-sectional anatomical diagrams of the tibia were taken from 3 levels. Lines representing wires were drawn crossing at the centre of the bone. The maximum crossing angles for an Ilizarov ring using safe anatomical corridors were calculated. A TSF ring was then superimposed on the image and angles recalculated taking into account impedance caused by the strut tabs. The angles were compared using a Students t-test taking p=0.05 as significant.

Results: The average maximum crossing angle of the Ilizarov wires was 61° compared with 36° for the TSF. At all 3 levels the angles were found to be significantly different (p=0.002).

Discussion: Limitations in the trans-osseous wire placement has implications for construct stability and therefore function. This may force the surgeon to make greater use of half pins, or more wires. We have shown significant differences in pin placement using the TSF which should be taken into consideration when using the system.


Orthopaedic Proceedings
Vol. 88-B, Issue SUPP_I | Pages 122 - 122
1 Mar 2006
Calder P Ramachandran M Hill R Jones D
Full Access

Normal acetabular development in developmental dysplasia of the hip (DDH) depends upon early and maintained congruent reduction. Computed tomography is an accepted method for evaluating this and attempts to quantify hip reduction, by various angular and linear measurements, have been reported.

The aim of this study was to assess initial CT scans, following open reduction in the older child with DDH, with comparison of outcome to evaluate prognostic value.

Method: Thirty consecutive patients underwent open reduction for DDH, with a mean age of 25.9 months at the time of operation. Acetabular morphology and the position of the femoral head were evaluated on the initial CT scan, taken on the first postoperative day, and AP pelvic radiograph taken at the latest follow-up.

Results: The acetabulae of the dislocated hips were found to be significantly more anteverted than the normal. The dislocated hips also had significantly increased lateral displacement both initially and at latest follow-up. Posterior displacement of the proximal femoral metaphysis should raise concern due to an association with the need for further surgical intervention. These results did not however correlate with outcome.

In conclusion, despite the significant differences noted between DDH and normal hips they did not predict acetabular development or persistent acetabular dysplasia.


Orthopaedic Proceedings
Vol. 88-B, Issue SUPP_I | Pages 127 - 127
1 Mar 2006
Ramachandran M Lau K Calder P Jones D
Full Access

Purpose: Congenital proximal radioulnar synostosis is a rare anomaly of failure of segmentation of the radius and ulna resulting in a fixed rotational position of the forearm from neutral to maximum pronation. Several surgical options have been proposed for the treatment of this condition. We have treated six forearms in five children with pronation deformity using derotational osteotomies of the radius and ulna with postoperative wire stabilisation of the ulna. The surgical technique and results of treatment with this method are presented.

Methods: With this technique, osteotomies were performed at the midshaft of the ulna and the distal diaph-yseal-metaphyseal junction of the radius. The insertion of intramedullary Ilizarov wires facilitated manual derotation of the radius and ulna to a functional position of 100 supination of the forearm. Postoperatively, the forearm was immobilised in a cast for an average of 6.3 weeks and the wire was removed when there was evidence of union. 3 boys and 2 girls with a mean age of 4.9 years underwent surgery with this method and were followed-up for an average of 29 months (range 12 to 43 months).

Results: Forearm position improved from an average pronation deformity of 68.3 degrees to the pre-planned position of 100 degrees supination in all cases. Bone union was achieved in all six forearms by 6.3 weeks. At their most recent follow-up, there was no loss of correction evident in any of the patients. There was one complication, namely haematoma formation at the radial osteotomy site mimicking compartment syndrome and requiring exploration, although no soft tissue compromise was evident.

Conclusion: The principal advantages of this technique include the ease of the surgical approach for the distal radial osteotomy, the longterm maintenance of rotational correction and the need for single wire stabilisation of the ulna only, which in theory reduces the potential risk of implant-related complications. We conclude that this modified forearm derotational osteotomy with wire stabilisation of the ulna alone is a safe and effective method for treating pronation deformity in children with congenital proximal radioulnar synostosis, although vigilance for early soft tissue complications is necessary.


Orthopaedic Proceedings
Vol. 87-B, Issue SUPP_III | Pages 394 - 394
1 Sep 2005
Calder P Reidy J Crone D Paterson J Barry M
Full Access

Introduction: A review of the treatment of 33 open fractures in 29 children over the period 1997 to 2002.

Method: Intravenous antibiotics, debridement and wound irrigation was performed prior to skeletal stabilisation incorporating plaster cast immobilisation (4%), K wire fixation (13%), screw fixation (13%), flexible intramedullary nail fixation (13%) and external fixation (57%). Secondary wound closure was undertaken if appropriate at 48 hours. The tibia was involved in 49% of cases with approximately equal distribution of other long bone extremities. Fractures were classified according to Gustilo et al (22% grade I, 26% grade II, 17% grade III and 35% grade IIIb).

Results: The average age was 10 years in 22 boys and 7 girls. Tibial fracture union was an average of 9 weeks in gradeI and II compared with 20 weeks for grade III. The remaining fractures healed at an average of 10 weeks. Non union occurred in one patient (tibia). There was on case of growth arrest of the distal tibia. There were no cases of osteomyelitis.

Discussion: Open fractures in children most often result from high energy trauma. An increase in fracture and soft tissue severity is associated with a delayed union. Physeal injuries require close observation for potential growth arrest.


Orthopaedic Proceedings
Vol. 86-B, Issue SUPP_III | Pages 298 - 298
1 Mar 2004
Achan P Calder P Barry M
Full Access

Aims: To compare the cost of intra-medullary implants used stabilising paediatric diaphyseal fractures with the clinical outcome. Methods: Between March 1994 and August 2001, at two centres, The Womenñs and Childrenñs Hospital, Adelaide, Australia and The Royal London Hospital, London UK 60 children were surgically treated for diaphyseal forearm fractures using Elastic Stable Intramedullary Nails (ESIN) or 2.5mm Kirschner wires. Having established no difference in the clinical outcome or subjective disability of either technique we compared the implant cost directly. Results: The two treatments both resulted in an excellent outcome with all fractures leading to union with no subjective disability. The Kirscner wires cost £3.00 per wire while the ESI Nails cost between £57.50 and £ 113.30 per wire, depending on the dimensions. Conclusions: We were not able to demonstrate any difference in outcome between ESIN and K-Wiring, although the nails do offer theoretical advantages. The cost implications of using the special implant are twenty fold or more, and as the pressures of cost cutting grow, we wonder if theoretical advantage is Òvalue for moneyÒ.


Orthopaedic Proceedings
Vol. 85-B, Issue SUPP_III | Pages 274 - 274
1 Mar 2003
Barry M Calder P Achan P
Full Access

Introduction: The majority of forearm fractures in children can be managed with a plaster cast alone and manipulation under anaesthetic as required. A small number of cases however require surgical intervention. A variety of methods are available but the use of elastic intramedullary nails is becoming the technique of choice.

Method: We present a two-centre study assessing the outcome of either Elastic StabJe Intramedullary Nails (ESIN) or Kirschner wires as the method of fracture stabilisation in diaphyseal forearm fractures of the radius and ulna.

Results: ESIN group: 24 children underwent ESIN fixation. There were 22 boys and 2 girls, mean age 9.4 years (1.4–15.2 years, p=O.ll). Indications for stabilisation included 21 cases for fracture instability (immediate or delayed,) 2 irreducible fractures and 1 open fracture. 14 children underwent surgery on the day they sustained their fracture. The remainder were operated on an average 6.5 days following injury (1–14 days). In the K wire group: 36 children underwent K-wires fixation with 2.5mrn wires. There were 21 boys and 15 girls, mean age 10.6 years (2.2–15.5 years). Indication for stabilisation included 22 cases for fracture instability , 6 irreducible fractures and 8 open fractures. 32 children underwent surgery on the day they sustained their fracture. The remaining 4 patients were operated on the following day.

Conclusions: All fractures united with no resultant subjective disability. The complication rate following K-wires was 16% and that following nail fixation 9%. Loss of forearm rotation was documented in 4 children in the K-wire group and 3 children stabilised with nails. These results confirm an excellent outcome following intramedullary fixation. We have demonstrated no difference in outcome between K-wires and ESIN, although the elastic nails do offer some theoretical advantages.


The Journal of Bone & Joint Surgery British Volume
Vol. 84-B, Issue 7 | Pages 1089 - 1090
1 Sep 2002
Calder P


Orthopaedic Proceedings
Vol. 84-B, Issue SUPP_II | Pages 130 - 130
1 Jul 2002
Tennent T Calder P Salisbury R Allen P Eastwood D
Full Access

The purpose of the study was to perform an independent assessment of the results of open reduction and internal fixation (ORIF) on a selected group of displaced intra-articular calcaneal fractures from two centres.

It still remains controversial whether to manage intraarticular calcaneal fractures conservatively or operatively with few long-term results. The identification of patients who may benefit from the procedure is still undecided.

Fifty fractures in 46 patients with a defined significant displacement of an intra-articular fracture of the calcaneum underwent ORIF by one of the two senior authors. Mean age at operation was 46 years and mean follow-up was 44 months. 88% of the injuries were due to a fall from a height. 30% of the patients had contralateral foot/ankle injuries, and 20% of the patients developed a superficial wound infection. The infection rate was significantly higher in patients whose surgery was delayed more than 14 days.

All patients were independently reviewed after a minimum two-year follow-up. A clinical, radiographic and subjective assessment of the outcome was made. The results were correlated to the original fracture type. The mean Atkins score was 88 (out of 100). Bilateral injuries fared worse. Heel pain at follow-up correlated with a poor score. Atkins scores over 90 occurred in 77% of Saunders Type II, 50% in Type III, and 43% in Type IV fractures. 94% returned to work at a mean of 10 months post-injury. Three patients have undergone a subtalar arthrodesis – two for persistent pain and one for a significant malunion. One patient required a flap but there have been no cases of chronic osteomyelitis.

In patients with significantly displaced fractures, ORIF is a worthwhile procedure with 90% of patients satisfied and 94% returning to work. Gross articular comminution does not preclude a good/excellent result if hindfoot alignment is restored. ORIF after fourteen days should be avoided due to the high risk of infection.


Orthopaedic Proceedings
Vol. 84-B, Issue SUPP_II | Pages 130 - 130
1 Jul 2002
Tennent T Calder P Salisbury R Allen P Eastwood D
Full Access

The purpose of the study was to perform an independent assessment of the results of open reduction and internal fixation (ORIF) on a selected group of displaced intra-articular calcaneal fractures from two centres.

It still remains controversial whether to manage intraarticular calcaneal fractures conservatively or operatively with few long-term results. The identification of patients who may benefit from the procedure is still undecided.

Fifty fractures in 46 patients with a defined significant displacement of an intra-articular fracture of the calcaneum underwent ORIF by one of the two senior authors. Mean age at operation was 46 years and mean follow-up was 44 months. 88% of the injuries were due to a fall from a height. 30% of the patients had contralateral foot/ankle injuries, and 20% of the patients developed a superficial wound infection. The infection rate was significantly higher in patients whose surgery was delayed more than 14 days.

All patients were independently reviewed after a minimum two-year follow-up. A clinical, radiographic and subjective assessment of the outcome was made. The results were correlated to the original fracture type. The mean Atkins score was 88 (out of 100). Bilateral injuries fared worse. Heel pain at follow-up correlated with a poor score. Atkins scores over 90 occurred in 77% of Saunders Type II, 50% in Type III, and 43% in Type IV fractures. 94% returned to work at a mean of 10 months post-injury. Three patients have undergone a subtalar arthrodesis – two for persistent pain and one for a significant malunion. One patient required a flap but there have been no cases of chronic osteomyelitis.

In patients with significantly displaced fractures, ORIF is a worthwhile procedure with 90% of patients satisfied and 94% returning to work. Gross articular comminution does not preclude a good/excellent result if hindfoot alignment is restored. ORIF after fourteen days should be avoided due to the high risk of infection.


The Journal of Bone & Joint Surgery British Volume
Vol. 83-B, Issue 5 | Pages 775 - 775
1 Jul 2001
Calder P