Introduction

The management of a significant bone defect following excision of a diaphyseal atrophic femoral non-union remains a challenge. Traditional bone transport techniques require prolonged use of an external fixator with associated complications. We present our clinical outcomes using a combined technique of acute femoral shortening, stabilised with a deliberately long retrograde intramedullary nail, accompanied by bifocal osteotomy compression and distraction osteogenesis to restore segment length utilising a temporary monolateral fixator.

Method

9 patients underwent the ‘rail and nail’ technique for the management of femoral non-union. Distraction osteogenesis was commenced on the 6th post-operative day. Proximal locking of the nail and removal of the external fixator was performed approximately one month after length had been restored. Full weight bearing and joint rehabilitation was encouraged throughout. Consolidation was defined by the appearance of 3 from 4 cortices of regenerate on radiographs.

Results

7 males and 2 females of adult age underwent treatment between 2009 and 2016. The mean lengthening was 6.6cm (3–10cm). The external fixator was removed at a mean 123 days (57–220), with an external fixation index of 20 days/cm. The regenerate healing index was 28 days/cm. There were no deep infections. Significant complications were seen in 4 patients including knee stiffness, a foot drop, delayed union of the non-union osteotomy (requiring exchange nailing and bone grafting) and revision nailing due to a prominent proximal tip.

Conclusion

The combined over-sized intramedullary nail and external fixator enables compression of the femoral osteotomy, alignment of the bone and controlled lengthening. Once the length has been restored, removal of the external fixator and proximal locking of the nail reduces the risk of complications associated with the fixator and stabilises the femur with the maximum working length of the nail. This small retrospective study demonstrates encouraging results for this complex clinical scenario.