THE INCIDENCE OF DEEP VEIN THROMBOSIS WITH EXTERNAL FIXATORS: ARE CURRENT THROMBOPROPHYLAXIS GUIDELINES APPROPRIATE?

British Limb Reconstruction Society (BLRS) AGM & Instructional Course



Abstract

Purpose

To investigate the incidence of deep vein thrombosis (DVT) and pulmonary embolism (PE) with external fixator use and to help establish whether current guidelines are appropriate.

Methods

Case notes of individuals undergoing external fixator application by the senior author (PC) from March 2005 to June 2011 were examined. In this period 207 individuals underwent 255 primary applications of Ilizarov, Taylor Spatial Frame (TSF) or monolateral fixator. Fixators applied were 173 tibial, 63 femoral and 19 to other bones. Records were obtained for 182 individuals (88%), representing 214 operations (84%).

Results

Two cases of DVT were found (1%). In both cases mechanical and chemical prophylaxis had been used, as guided by risk assessment. One of these individuals also experienced a PE. This person was of notably high risk, surgery involving excision of tibial adamantinoma and a high body mass index (45). He had also recently travelled from overseas (a travel time of over 3 hours). Other than surgical time there was one additional risk factor in 39 cases, two additional risk factors in four and three additional risk factors in four.

Conclusions

Little evidence exists about the incidence of DVT and PE with the use of external fixators. The National Institute of Health and Clinical Excellence (NICE) provide guidance for thromboprophylaxis in orthopaedic surgery with specific recommendations for hip and knee arthroplasty and hip fracture. For orthopaedic surgery other than lower limb arthroplasty NICE recommends thromboprophylaxis is guided by risk factors on a case by case basis. Our findings raise the question of whether extended course chemical thromboprophylaxis, as for lower limb arthroplasty, should be employed for high risk individuals undergoing application of external fixator.