Abstract
Introduction
No published work exists regarding deep vein thrombosis (DVT) and pulmonary embolism (PE) incidence with the elective use of external fixators. The aim of this work was to establish the rate of DVT and PE in such cases to help inform whether thromboprophylaxis guided by risk factors is adequate or if a more aggressive approach is required.
Patients and methods
Information from a prospectively maintained electronic database and case notes were examined for consecutive patients from March 2005 to June 2011. Occurrence of DVT and PE, detected by ultrasound or CT angiogram, were recorded. Risk factors for thromboembolism, age, weight, height, surgical indications, type of surgery and operative time were recorded. As recommended by the National Institute for Health and Clinical Excellence (NICE) thromboprophylaxis use is guided by risks of thromboembolism and bleeding. For adults and older adolescent patients contralateral leg compression stockings and an intraoperative calf pump were used. Mobilisation began the morning after surgery and the majority of cases permitted to bear weight fully.
Results
Two hundred and seven (207) individuals underwent 255 primary applications of Ilizarov, Taylor Spatial Frame (TSF) or monolateral fixator, 173 tibial, 63 femoral and 19 to other bones. Case notes were obtained for 182 individuals (88%), representing 214 operations (84%).
One DVT and one PE were recorded, an overall incidence of 2/214 (0.9%) (excluding those under 16 years old 2/143 (1.4%)). In both cases mechanical and chemical prophylaxis had been used as guided by risk assessment. The PE was sustained by a person of notably high risk, surgery involving excision of tibial adamantinoma and a high body mass index (45). He had also recently travelled from overseas (a travel time of over 3 hours).
Conclusions
The rate of DVT/PE for elective application of external fixators is low with risk assessment guiding prophylaxis.