header advert
Results 101 - 152 of 152
Results per page:
Orthopaedic Proceedings
Vol. 91-B, Issue SUPP_I | Pages 25 - 25
1 Mar 2009
Glyn-Jones S Beard D Murray D Gill H
Full Access

Introduction: Interest in hip resurfacing has recently been renewed by the introduction of metal-on-metal designs; it is being increasingly used for young patients, with over 30,000 implanted worldwide. The 5 year clinical results appear promising, but there are no long term data available. Radiostereometry (RSA) measures of implant migration have been able to predict implant failure; specifically large and continuous migration predicts aseptic loosening. We present the results of a five year RSA study examining the migration of the Birmingham Hip Resurfacing (BHR).

Methods: Twenty-four subjects with primary OA were implanted with the BHR device and with bone markers for RSA. RSA measurements were taken at 3, 6, 12, 24 and 60 months. The migration of the head and the tip of femoral component were measured in 3D.

Results: Preliminary analysis showed that the total 3D migration of the head and tip over five years was 0.32mm and 0.23mm respectively.

Discussion: A distal migration of more than 0.4mm over 2 years increases the likelihood of failure in conventional stems. The total migration of the BHR was approximately 0.3mm over a five year period, significantly less than cemented THR devices. The device is stable and this is promising for long-term survival.


Orthopaedic Proceedings
Vol. 90-B, Issue SUPP_III | Pages 537 - 538
1 Aug 2008
Ganapathi M Jones S Roberts P
Full Access

Aims: The aims of our study were:

to measure the total metal content in cell saver blood recovered during revision hip arthroplasty,

to evaluate the efficacy of centrifuging and washing the recovered blood in reducing the metal content,

to investigate whether transfusion of the salvaged blood resulted in a significant increase in the metal ion levels in the patients’ blood in the immediate post-operative period.

Materials and methods: We analysed the levels of metallic debris and metal ions in cell saver blood in nine patients undergoing revision hip replacement. Using inductively coupled plasma mass spectrometry (ICP-MS), the levels were measured for titanium, aluminium, vanadium, chromium, cobalt, nickel and molybdenum. The metal ion levels were analysed using a dilution technique and the total metal content levels (particulate debris and ions) were analysed with a digestion technique.

Results: Significantly higher levels of metal ions and metal debris were found in the pre-processed blood compared with the processed blood (after centrifuging and washing). The ion levels in the processed blood were not high enough to cause a significant increase in the patients’ immediate post-operative blood ion levels when compared with pre-operative levels.

Discussion: There are markedly elevated levels of metal ions and particulate metal debris in the blood salvaged during revision total hip arthroplasty. The processing of the recovered blood in a commercial “cell saver” significantly reduces the total metal load that is re-infused. Re-infusion of salvaged blood does not result in elevated metal ion levels in the immediate post-operative period.


Orthopaedic Proceedings
Vol. 90-B, Issue SUPP_III | Pages 546 - 547
1 Aug 2008
Kotwal R Ganapathi M John A Maheson M Jones S
Full Access

Aim: To determine the outcome and need for subsequent surgery in patients following successful closed reduction of dislocation after primary total hip arthroplasty (THA) and the financial implications of re-operation.

Methods: Data was retrospectively obtained from radiographs and patient case notes for all dislocated primary hip replacements presenting to the University Hospital of Wales from January 2000 till November 2005. Records were analysed with a minimum of 1 year follow-up to determine the outcome and need for subsequent surgery following successful closed reduction of dislocation after primary THA. Factors studied include age at primary surgery, indications, components, approach, head size, duration since surgery and direction of dislocation

Results: Over the 6 year study period, 98 patients presented with 100 first time dislocated primary total hip replacements. All the dislocations underwent successful closed reduction. 62 (62%) hips re-dislocated more that once. At minimum follow up of 1 year, 7 patients had died and were excluded from the final study group. Of the remaining 93 hips, 46 patients have had no further surgery. 44 THA’s have undergone revision procedures and 3 are waiting to have revision surgery (51% in total). Of those who have undergone revision surgery, 7 hips re-dislocated since and 3 of those needed further re-revision.

Discussion: Dislocation following primary THA remains a problem with varying dislocation rates quoted in the literature. In our series, 51% of patients presenting with dislocation required revision surgery. All patients in this series had 28 mm or smaller femoral heads. The financial impact of the burden of revision surgery continues to increase. In this series in isolation the cost of revision surgery totalled greater that £500,000.


Orthopaedic Proceedings
Vol. 90-B, Issue SUPP_III | Pages 534 - 534
1 Aug 2008
Ganapathi M Paul IB Clatworthy E John A Maheson M Jones S
Full Access

Aim: To investigate the outcome following revision total hip arthroplasty (THA) using 36 mm and 40 mm modular femoral heads.

Methods: Details were retrieved from our arthroplasty database regarding all revision THAs done in our unit using 36 mm and 40 mm femoral heads. Follow-up information was obtained from patient records and telephone conversation.

Results: The cohort considered totalled 107 revision THAs, 93 using a 36 mm head and 14 using a 40 mm head. All received either highly cross-linked UHMWPE liners or metal on metal liners. The indications for revisions were recurrent instability in eight, periprosthetic fracture in 11, second stage revision in 24, fracture of the femoral stem in one and aseptic loosening in the remaining 63. At a minimum follow up of one year, information was not available for five but they did not have any record of dislocation. Out of the remaining 102 patients, dislocation occurred in 4 hips (3.9%). None of the revisions done with 40 mm head dislocated. In two of the dislocations, the initial indication for revision THA was recurrent instability and if they are excluded, the dislocation rate was 1.96%.

Discussion: Dislocation and the sequalae of recurrent instability remains a significant problem following revision THA and the existing literature varies greatly in the quoted dislocation rates. We believe that the use of 36 mm and 40 mm femoral heads in our unit has been a major factor in low (3.6%) dislocation rate following revision THA. To date there have been no problems encountered resulting from the use of highly cross-linked UHMWPE.


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 7 | Pages 847 - 851
1 Jul 2008
Pandit H Glyn-Jones S McLardy-Smith P Gundle R Whitwell D Gibbons CLM Ostlere S Athanasou N Gill HS Murray DW

We report 17 patients (20 hips) in whom metal-on-metal resurfacing had been performed and who presented with various symptoms and a soft-tissue mass which we termed a pseudotumour. Each patient underwent plain radiography and in some, CT, MRI and ultrasonography were also performed. In addition, histological examination of available samples was undertaken.

All the patients were women and their presentation was variable. The most common symptom was discomfort in the region of the hip. Other symptoms included spontaneous dislocation, nerve palsy, a noticeable mass or a rash. The common histological features were extensive necrosis and lymphocytic infiltration. To date, 13 of the 20 hips have required revision to a conventional hip replacement. Two are awaiting revision.

We estimate that approximately 1% of patients who have a metal-on-metal resurfacing develop a pseudotumour within five years. The cause is unknown and is probably multifactorial. There may be a toxic reaction to an excess of particulate metal wear debris or a hypersensitivity reaction to a normal amount of metal debris. We are concerned that with time the incidence of these pseudotumours may increase. Further investigation is required to define their cause.


Orthopaedic Proceedings
Vol. 90-B, Issue SUPP_II | Pages 398 - 398
1 Jul 2008
Glyn-Jones S Pandit H Whitwell D Athanasou N Gibbons M
Full Access

Purpose of study: We report the results of a prospective case series of 10 patients who developed tumour-like masses following resurfacing arthroplasty

Method: Ten subjects were referred to the tumour service at the Nuffield Orthopaedic Centre with symptomatic masses around the hip, all had previously received a resurfacing arthroplasty.

We report the clinical, radiographic and histologic features of these cases.

Results: MRI and ultrasound scanning was preformed, which demonstrated masses with solid and cystic components.

Biopsy was performed and subsequent histological examination revealed a profound plasma-cell lymphocytic response associated with metal wear debris.

There were no infections in this series.

Three subjects required revision surgery.

Conclusion: Over 50,000 resurfacing arthroplasties have been implanted worldwide over the past ten years. Although the early clinical results are encouraging little is known about the long term consequences of large head metal on metal bearing surfaces. Despite this, these devices are being widely marketed and are often implanted in younger patients. Resurfacing arthroplasties are associated with high serum and urine metal ion concentrations, metal particles have also been shown to migrate along the lymphatic system. In addition, there is now evidence that high local metal ion concentrations can induce haempoietic cancers.

This study suggests that resurfacing arthoplasty can also induce a local hypersensitivity reaction in response to metal wear debris. It therefore raises new concerns regarding the long-term safety of this procedure.


Orthopaedic Proceedings
Vol. 90-B, Issue SUPP_II | Pages 381 - 381
1 Jul 2008
Ganapathi M Jones S Roberts P
Full Access

Purpose: The aims of our study were: (i) to measure the total metal content in cell saver blood recovered during revision hip arthroplasty, (ii) to evaluate the efficacy of centrifuging and washing the recovered blood in reducing the metal content, (iii) to investigate whether transfusion of the salvaged blood resulted in a significant increase in the metal ion levels in the patients’ blood in the immediate post-operative period.

Materials and methods: We analysed the levels of metallic debris and metal ions in cell saver blood in nine patients undergoing revision hip replacement. Using inductively coupled plasma mass spectrometry (ICP-MS), the levels were measured for titanium, aluminium, vanadium, chromium, cobalt, nickel and molybdenum. The metal ion levels were analysed using a dilution technique and the total metal content levels (particulate debris and ions) were analysed with a digestion technique.

Results: Significantly higher levels of metal ions and metal debris were found in the pre-processed blood compared with the processed blood (after centrifuging and washing). The ion levels in the processed blood were not high enough to cause a significant increase in the patients’ immediate post-operative blood ion levels when compared with pre-operative levels.

Conclusion: There are markedly elevated levels of metal ions and particulate metal debris in the blood salvaged during revision total hip arthroplasty. The processing of the recovered blood in a commercial ‘cell saver’ sig-nificantly reduces the total metal load that is re-infused. Re-infusion of salvaged blood does not result in elevated metal ion levels in the immediate post-operative period.


Orthopaedic Proceedings
Vol. 90-B, Issue SUPP_II | Pages 389 - 389
1 Jul 2008
Gorva A Metcalfe J Rajan R Jones S Fernandes J
Full Access

Introduction: Prophylactic pinning of an asymptomatic hip in SCFE is controversial. Bone age has been used as evidence of future contralateral slip risk and used as an indication for such intervention. The efficacy of bone age assessment at predicting contralateral slip was tested in this study.

Patients and Methods: 18 Caucasian children prospectively had bone age assessment using wrist and hand x-rays when presenting with a unilateral SCFE. Patients and parents were informed about the chance of con-tralateral slip and risks of prophylactic fixation, and advised to attend hospital immediately on development of symptoms in contralateral hip. After in-situ fixation of the affected side prospective monitoring in outpatient department was performed. Surgical intervention was undertaken if the contralateral hip was symptomatic.

Results: Three children (2 boys) went on to develop to a contralateral slip at a mean of 20 months from initial presentation. 6 children (5 boys) were deemed at risk of contralateral slip due to a bone age below 12.5 years for boys and 10.5 for girls. Only one from this group developed a contralateral slip. The relative risk of proceeding to contralateral slip when the bone age is below the designated values was 1 (95% confidence interval of 0.1118 to 8.95). The sensitivity and specificity were 33% and 66% respectively. With positive predictive value of 15% and diagnostic efficiency of 61%.

Conclusion: Delayed bone age by itself is not a good predictor of future contralateral slip at initial presentation. Routine prophylactic pinning is not justified based on bone age alone, with the risks of surgical fixation it carries. Prospective long term longitudinal study is required.


Orthopaedic Proceedings
Vol. 90-B, Issue SUPP_II | Pages 336 - 336
1 Jul 2008
Gorva A Metcalfe J Rajan R Jones S Fernandes J
Full Access

Introduction: Prophylactic pinning of an asymptomatic hip in SCFE is controversial. Bone age has been used as evidence of future contralateral slip risk and used as an indication for such intervention. The efficacy of bone age assessment at predicting contralateral slip was tested in this study.

Patients and Methods: 18 Caucasian children prospectively had bone age assessment using wrist and hand x-rays when presenting with a unilateral SCFE. Patients and parents were informed about the chance of con-tralateral slip and risks of prophylactic fixation, and advised to attend hospital immediately on development of symptoms in contralateral hip. After in-situ fixation of the affected side prospective monitoring in outpatient department was performed. Surgical intervention was undertaken if the contralateral hip was symptomatic.

Results: Three children (2 boys) went on to develop to a contralateral slip at a mean of 20 months from initial presentation. 6 children (5 boys) were deemed at risk of contralateral slip due to a bone age below 12.5 years for boys and 10.5 for girls. Only one from this group developed a contralateral slip. The relative risk of proceeding to contralateral slip when the bone age is below the designated values was 1 (95% confidence interval of 0.1118 to 8.95). The sensitivity and specificity were 33% and 66% respectively. With positive predictive value of 15% and diagnostic efficiency of 61%.

Conclusion: Delayed bone age by itself is not a good predictor of future contralateral slip at initial presentation. Routine prophylactic pinning is not justified based on bone age alone, with the risks of surgical fixation it carries. Prospective long term longitudinal study is required.


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 5 | Pages 556 - 561
1 May 2008
Glyn-Jones S McLardy-Smith P Gill HS Murray DW

The creep and wear behaviour of highly cross-linked polyethylene and standard polyethylene liners were examined in a prospective, double-blind randomised, controlled trial using radiostereometric analysis.

We randomised 54 patients to receive hip replacements with either highly cross-linked polyethylene or standard liners and determined the three-dimensional penetration of the liners over three years.

After three years the mean total penetration was 0.35 mm (SD 0.14) for the highly cross-linked polyethylene group and 0.45 mm (SD 0.19) for the standard group. The difference was statistically significant (p = 0.0184). From the pattern of penetration it was possible to discriminate creep from wear. Most (95%) of the creep occurred within six months of implantation and nearly all within the first year. There was no difference in the mean degree of creep between the two types of polyethylene (highly cross-linked polyethylene 0.26 mm, SD 0.17; standard 0.27 mm, SD 0.2; p = 0.83). There was, however, a significant difference (p = 0.012) in the mean wear rate (highly cross-linked polyethylene 0.03 mm/yr, SD 0.06; standard 0.07 mm/yr, SD 0.05). Creep and wear occurred in significantly different directions (p = 0.01); creep was predominantly proximal whereas wear was anterior, proximal and medial.

We conclude that penetration in the first six months is creep-dominated, but after one year virtually all penetration is due to wear. Highly cross-linked polyethylene has a 60% lower rate of wear than standard polyethylene and therefore will probably perform better in the long term.


Orthopaedic Proceedings
Vol. 90-B, Issue SUPP_I | Pages 166 - 166
1 Mar 2008
Hauptfleisch J Glyn-Jones S Gill H McLardy-Smith P Murray D
Full Access

The Charnley Elite femoral component was first introduced in 1992 as a new design variant of the original Charnley femoral component (De Puy, Leeds, UK) with modified neck and stem geometry. The original component had undergone few changes in nearly forty years and has excellent long-term results. Early migration of the new stem design was determined by Roentgen Stereophotogrammetric Analysis (RSA)1. Rapid early migration of a component relative to the bone, measured by RSA, is predictive of subsequent aseptic loosening for a number of femoral stems. As there was rapid early migration and rotation of the Charnley Elite stem, we predicted that the long-term results would be poor. An outcome assessment is indicated as stems of this type are still being implanted.

One hundred Charnley Elite stems, implanted in our centre between 1994 and 1997 were included in a prospective, cross-sectional follow-up study. Outcome measures include validated clinical scores (Charnley hip score, Harris hip score and Oxford hip score) and radiological scores (Gruen classification) as well as revision rates over the past 10 years.

The clinical follow-up supports the RSA predictions of early failure of the Charnley Elite femoral stem.


Orthopaedic Proceedings
Vol. 88-B, Issue SUPP_III | Pages 436 - 436
1 Oct 2006
Rajan RA Metcalfe J Konstantoulakis C Jones S Sprigg A
Full Access

Introduction: The assessment of bone age using the standard Gruel and Pyle chart based on hand and wrist radiographs is usually carried out by Senior Radiologists. We performed a study to look at both intra and inter observer variability with different grades of clinicians.

Materials and Methods: 30 sets of wrist radiographs were selected at random. The investigators included a Senior Radiographer, a Consultant and Registrar Radiologist an Orthopaedic Consultant and Senior Orthopaedic Fellow.

Discussion: The Radiology team appear to be more consistent in their readings for the assessment of skeletal bone age than the Orthopaedic team. Howevr, it is interesting to note that although the Orthopaedic team are less consistent, when looking at the inter-observer variability, it suggests that both teams are equally well equipped to perform the task.

Conclusion: Our study suggests that we should not cross professional boundaries. Render unto Caeser what is Ceaser’s!


Orthopaedic Proceedings
Vol. 88-B, Issue SUPP_III | Pages 436 - 436
1 Oct 2006
Devalia KL Moras P Pagdin J Jones S Fernandes JA
Full Access

Aim of the study: To evaluate the final outcome following joint distraction and reconstruction in patients with complex knee contractures in a select group with varied aetiology.

Materials and methods: Retrospective study of six patients (nine knees, 3 bilateral) with severe knee flexion contractures treated by gradual distraction using ring fixators. Most cases were syndromic or arthrogrypotic.. Case notes and radiographs were reviewed to assess the mobility and functional range of motion before and after the procedure.

Results: Staged procedures was carried out in 6 out of 9 knees accompanied by soft tissue releases, realignment of extensor mechanism and bony and joint realignment. The average age at operation was nine years and nine months and the mean follow up was 53 months. The average time spent in frame was 20 weeks. The correction was graded as good to excellent in 5 knees, fair in 1 and poor in 3 knees. The total arc of motion remained unchanged though the functional range of movement improved. The mobility improved significantly in most patients who were independent walkers with or without splints. Complications were of rebound phenomenon after frame removal in arthrogrypotic children, transient neuropraxia of common peroneal nerve in 2 epiphyseal separation in one and 3 sustained undisplaced fractures during mechanical distraction.

Conclusion: Syndromic and arthrogrypotic knee contractures are difficult to treat due to their severity and complexity. Planned staged procedures with joint distraction, patellar and bony realignment can produce satisfactory outcome in most making them functional independent ambulators.


Orthopaedic Proceedings
Vol. 88-B, Issue SUPP_III | Pages 436 - 436
1 Oct 2006
Moras P Belthur M Jones S Fernandes J
Full Access

Aim: To report our experience and early results with the Ilizarov pelvic support realignment lengthening osteotomy for complex hip pathology in children.

Material & Methods: Between 1997 & 2004, seven children were treated with this technique and five have completed treatment. The treatment was undertaken for sequelae of DDH in 4 patients and septic arthritis in 1 patient. The median age of the patients was 13(10–17). There were 3 boys and 2 girls. The outcome assessment was performed using the Harris hip score, clinical and radiological parameters.

Results: 4 patients presented with hip instability, shortening of the lower limb, pain and restricted motion. The remaining patient presented with a nonfunctional ankylosis with shortening. The median time between the onset of symptoms and the operation was 3 years (2–5). The median preoperative leg-length discrepancy was 3 cm (2–4.5). The median fixator time was 5 months (3–6). The median follow-up was 24 months (9–72).

Patients had improvement of pain, posture, hip instability, walking ability and limb length discrepancy. The median lengthening of the femur was 3 cm (2–5). The mechanical axis was realigned in all patients. All patients were satisfied with the outcome. Planned secondary contra lateral epiphyseodesis was required to equalise leg length in 2 patients. Complications included a stiff knee (1) that required a Judet quadricepsplasty, premature consolidation (1) that required reosteotomy and knee subluxation (1) that required cross knee stabilisation.

Conclusion: This is a safe and reliable alternative option to joint replacement, Colonna arthroplasty and arthrodesis for the reconstruction of multiply operated complex hip pathology in children.


Orthopaedic Proceedings
Vol. 88-B, Issue SUPP_III | Pages 436 - 437
1 Oct 2006
Pagdin J McKeown E Madan S Jones S Davies A Bell M Fernandes J Saleh M
Full Access

Purpose: The aim of this part retrospective and part prospective study was to establish the incidence of pinsite infections and assess evolution of changes in practice

Methods: Data was collected retrospectively and prospectively for pin site infections from the inception of limb reconstruction service viz. 1985 to January 2002. There were 812 patients, 1042 limb segments, and 9935 pins. The various external fixators used were limb reconstruction system (LRS) 549; Ilizarov 397; Sheffield ring fixator (SRF); Dynamic axial fixator (DAF) 35; LRS/Sequoia 8; LRS/Garche 7; and Pennig 5.

Results: The pin site infections were graded from 0 to 6 ( Saleh & Scott). There were no infections in 206 segments. The infection grade is shown below:

We changed our pin tract care practice from 1996. We had a significant decrease in pin tract infections since then (p< 0.0001). We also found that using Ilizarov wires had significantly less infections than with half pins used with monolateral fixators (p< 0.0001; linear trend, p= 0.0338). There were 48 patients that required hospital admissions for IV antibiotics. and of these 10 patients required debridement. There were no residual long lasting infections or chronic osteomyelitis.

Conclusion: Attention to detail in insertion of wires and half pins is crucial to avoid pin site infections. This audit supports the fact that external fixation is a safe method from the point of view of infection contrary to general belief.


Orthopaedic Proceedings
Vol. 88-B, Issue SUPP_III | Pages 368 - 368
1 Oct 2006
Gill H Polgar K Glyn-Jones S McLardy-Smith P Murray D
Full Access

Introduction: The design philosophy of polished tapered THR stems, such as the Exeter, intend for them to migrate distally within the cement mantle. In addition it is likely that micromotion occurs as a result of functional activity. The pattern of induced stresses will be a function of stem geometry & surface finish, as well as applied loading. Aim: To investigate the stresses induced in the cement mantle of a polished tapered THR stem during functional activity.

Method: Using Roentgen Stereophotogrammetric Analysis (RSA) dynamically induced micro-motion (DIMM) was measured in 21 patients implanted with Exeter stems. DIMM was measured as the difference in stem position in going from double to single leg stance on the operated limb. All subjects were measured 3 months post-operatively. A finite element (FE) model of the femur, including all muscles was used to investigate the stress distribution within the cement; contact was modelled with sliding elements allowing separation. The model was validated by comparison to the DIMM measurements.

Results: The Exeter stem demonstrated significant DIMM(p < 0.017), the average motions are given in the table below. The FE model, with sliding contacts was able to predict similar distal migration of the head. The peak minimum principal stress in the mantle was approx 33MPa and occurred in the proximal medial region. Movements occurred at the stem/cement interface.

Discussion and Conclusion: It is possible to measure DIMM in the Exeter stem and combining this with FE modelling the mechanism of stress transfer between the stem and mantle can be investigated in a manner that can be validated.


Orthopaedic Proceedings
Vol. 88-B, Issue SUPP_III | Pages 434 - 435
1 Oct 2006
Gorva AD Metcalfe J Rajan R Jones S Fernandes JA
Full Access

Introduction: Prophylactic pinning of an asymptomatic hip in SCFE is controversial. Bone age has been used as evidence of future contralateral slip risk and used as an indication for such intervention. The efficacy of bone age assessment at predicting contralateral slip was tested in this study.

Patients and Methods: 18 Caucasian children prospectively had bone age assessment using wrist and hand x-rays when presenting with a unilateral SCFE. Patients and parents were informed about the chance of contralateral slip and risks of prophylactic fixation, and advised to attend hospital immediately on development of symptoms in contralateral hip. After in-situ fixation of the affected side prospective monitoring in outpatient department was performed. Surgical intervention was undertaken if the contralateral hip was symptomatic.

Results: Three children (2 boys) went on to develop to a contralateral slip at a mean of 20 months from initial presentation. 6 children (5 boys) were deemed at risk of contralateral slip due to a bone age below 12.5 years for boys and 10.5 for girls. Only one from this group developed a contralateral slip. The relative risk of proceeding to contralateral slip when the bone age is below the designated values was 1 (95% confidence interval of 0.1118 to 8.95).

Conclusion: Delayed bone age by itself is not a good predictor of future contralateral slip at initial presentation. Routine prophylactic pinning is not justified based on bone age alone, with the risks of surgical fixation it carries. Prospective long term longitudinal study is required.


Orthopaedic Proceedings
Vol. 88-B, Issue SUPP_I | Pages 45 - 45
1 Mar 2006
Glyn-Jones S Gill R McLardy-Smith P Murray D
Full Access

Introduction Polyethylene wear debris is an important cause of failure in cemented total hip arthroplasty. As a result of the biological response to debris at the bone-cement interface, osteolysis and subsequent failure occurs in both femoral and acetabular components. Most acetabular components and liners are made of ultra high molecular weight polyethylene (UHMWPE). Cross-linking UHMWPE has been shown to significantly reduce abrasive wear in hip simulator studies. The wear rates measured in vitro do not always correlate with the wear rates measured in clinical studies[1]. Some new polyethylenes have shown catastrophic wear in clinical studies despite encouraging hip simulator study results[2]. The aim of this study was to compare the wear of standard UHMWPE to that of cross-linked UHMWPE (Longevity, Zimmer, Warsaw, USA)

Patients and Methods This was a prospective, double blind, randomised control trial. 50 subjects were recruited, all of whom received the cemented CPT stem and uncemented Trilogy liner (Zimmer, UK). Subjects were randomised to receive either a standard Trilogy liner or a Longevity liner at the time of operation. Both liners are identical in appearance. All liners were of a neutral configuration. RSA was used to measure linear wear. This was calculated by measuring the distance between the centre of the femoral head and the centre of the acetabular liner. The preliminary results of the study are presented.

Results Both groups underwent significant wear over two years. The two year linear wear of the cross-linked UHMWPE was 0.3mm (+/− 0.06mm, p< 0.001). The two year linear wear of the standard UHMWPE was 0.39mm (+/− 0.04mm, p< 0.001). No significant difference existed between the two groups (p=0.24). Both cohorts had around 0.15 to 0.2 mm of measured wear per year. Cross-linked UHMWPE therefore underwent less wear than standard UHMWPE at two years, however this difference was not statistically significant.

Discussion This study suggests that Longevity UHMWPE has similar wear properties to standard UHMWPE in the first two years following implantation. This does not correlate with in vitro hip simulator studies of Longevity polyethylene, which show a significantly lower wear rate than standard UHMWPE. It suggests that hip simulator studies may be of little value in predicting in vivo wear rates and that all new types of polyethylene should be evaluated clinically and radiologically prior to general release. Whether both cohorts continue to wear at similar rates will only be revealed through continued observation.


Orthopaedic Proceedings
Vol. 88-B, Issue SUPP_I | Pages 119 - 119
1 Mar 2006
Johnson P Kurien B Belthur M Jones S Flowers M Fernandes J
Full Access

Aim: To report our experience and early results with flexible nailing for unstable or irreducible displaced proximal humeral fractures in children.

Material & methods: Between 1997 & 2004, 15 children with unstable or irreducible displaced fractures of the proximal humerus were treated with closed/open reduction and flexible IM nailing. There were 10 boys and 5 girls. The median age of the patients was 12.5 years (9–15). Thirteen children had a Salter – Harris II, Neer grade III/IV fracture and 2 children had metaphyseal fractures. The outcome assessment was performed using the shoulder score, clinical and radiological parameters.

Results: All fractures united. None of the patients had a clinically significant malunion/shortening. Three patients had irritation at the nail insertion site. One patient had a transient radial nerve neurapraxia. There were no other operative or postoperative complications. The flexible nails were removed at a median time of 6 months (1.5–10) in 12 patients and 3 patients are awaiting removal. At a median follow-up of 30 months (4–66) all patients had a normal or near normal glenohumeral motion, full strength and all reported regaining full pre-injury functional use of the involved extremity.

Conclusion: Flexible nailing can be used safely to maintain reduction in unstable or irreducible displaced fractures of the proximal humerus and allows early return to normal activities and function with minimal complications. This treatment is also useful in older children who have minimal remodelling potential.


Orthopaedic Proceedings
Vol. 88-B, Issue SUPP_I | Pages 35 - 35
1 Mar 2006
Al Hussainy H Jones S Ali F Club S Bostock S
Full Access

Arthroscopic procedures may be associated with considerable pain in the first 24 hours. Intra-articular bupi-vacaine provides good analgesia but is short lasting. Intra-articular morphine has been shown to prolong postoperative analgesia in knee and ankle arthroscopy. The aim of this study is to assess the safety and analgesic effect of intra-articular morphine following day case wrist arthroscopy.

Ethical approval was firstly obtained. 31 patients were randomly assigned to one of 2 groups in a double blind clinical study. Group 1 received 5ml of 0.5% bupi-vacaine intra-articularly with 5mg of morphine subcutaneously. Group 2 received 5ml of 0.5% bupivacaine and 5mg of morphine intra-articularly. There were 15 patients (mean age 41.2 years) in group 1, and 16 patients (mean age 38.9 years) in group 2. Postoperatively pain was assessed using a 100mm visual analogue pain scale (VAPS) at 1, 2, 6 and 24 hours. Analgesia requirements were recorded at these times post operatively. The presence of nausea, vomiting, other complications and patient satisfaction were recorded.

Visual analogue pain scores did not show any significant difference between the groups at 1, 2, 6 and 24 hours. Supplementary analgesic consumption over the 24 hour period was slightly greater in group 1 than in group 2. None of the patients who had intra-articular Morphine had vomiting nor any other complications and did not require anti-emetics. Most patients in either group were satisfied with the level of postoperative analgesia.

Intra-articular bupivacaine with or with out morphine provides adequate postoperative pain relief following wrist arthroscopy. There seems to be little difference between the two methods studied.


Orthopaedic Proceedings
Vol. 88-B, Issue SUPP_I | Pages 73 - 73
1 Mar 2006
Hauptfleisch J Glyn-Jones S Beard D Gill H McLardy-Smith P Murray D
Full Access

Introduction: The Charnley Elite femoral component was first introduced in 1992 as a new design variant of the original Charnley femoral component (De Puy, Leeds, UK) with modified neck and stem geometry. The original component had undergone few changes in nearly forty years and has excellent long-term results.

Early migration of the new stem design was determined by Roentgen Stereophotogrammetric Analysis (RSA). Rapid early migration of a component relative to the bone, measured by RSA, is predictive of subsequent aseptic loosening for a number of femoral stems. As there was rapid early migration and rotation of the Charnley Elite stem, we predicted that the long-term results would be poor. An outcome assessment is required as stems of this type are still being implanted.

Materials and method: One hundred Charnley Elite stems, implanted in our centre between 1994 and 1997 were included in a prospective, cross-sectional follow-up study. Outcome measures include validated clinical scores (Charnley hip score, Harris hip score and Oxford hip score) and radiological scores (Gruen classification) as well as revision rates over the past 10 years.

Results: The preliminary analysis results are given. The mean time to follow-up was 8.28 years. 20 patients have died due to causes unrelated to their operations. 10 patients had stem revisions: 9 for aseptic loosening and 1 for a peri-prosthetic fracture. This indicates a significant 10% failure rate of the prosthesis in less than 10 years.

Preliminary clinical scores in the patients who had not undergone any subsequent surgery were adequate (Oxford Hip Score mean average of 23.9).

Thirteen percent of radiographs analysed had evidence of loosening, giving an overall loosening rate of 14% at 8 years.

Discussion and conclusion: The clinical follow-up supports the RSA predictions of early failure of the Charnley Elite femoral stem.


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 2 | Pages 179 - 183
1 Feb 2006
Hauptfleisch J Glyn-Jones S Beard DJ Gill HS Murray DW

We performed a clinical and radiological study to determine the rate of failure of the Charnley Elite-Plus femoral component. Our aim was to confirm or refute the predictions of a previous roentgen stereophotogrammetric analysis study in which 20% of the Charnley Elite-Plus stems had shown rapid posterior head migration. It was predicted that this device would have a high early rate of failure.

We examined 118 patients at a mean of nine years after hip replacement, including the 19 patients from the original roentgen stereophotogrammetric study. The number of revision procedures was recorded and clinical and radiological examinations were performed.

The rate of survival of the femoral stems at ten years was 83% when revision alone was considered to be a failure. It decreased to 59% when a radiologically loose stem was also considered to be a failure. All the patients previously shown in the roentgen stereophotogrammetric study to have high posterior head migration went on to failure. There was a highly significant difference (p = 0.002) in posterior head migration measured at two years after operation between failed and non-failed femoral stems, but there was no significant difference in subsidence between these two groups.

Our study has shown that the Charnley Elite-Plus femoral component has an unacceptably high rate of failure. It confirms that early evaluation of new components is important and that roentgen stereophotogrammetric is a good tool for this. Our findings have also shown that rapid posterior head migration is predictive of premature loosening and a better predictor than subsidence.


Orthopaedic Proceedings
Vol. 87-B, Issue SUPP_III | Pages 224 - 224
1 Sep 2005
Glyn-Jones S Gill H McLardy-Smith P Murray D
Full Access

Introduction: The Birmingham Hip Resurfacing (BHR) is a metal on metal prosthesis with no published independent clinical studies. It is increasingly used as an alternative to stemmed prostheses in younger patients.

This study presents the 2 year migration results of the BHR femoral component using Roentgen Stereophoto-grammteric Analysis (RSA).

Methods: 26 hips in 24 subjects underwent a BHR, through the postero-lateral approach using CMW3G cement. RSA marker balls were placed in the cortical bone of the femur intra-operatively. The femoral component migration was measured at intervals of 3, 6, 12 and 24 months postoperatively using the Oxford RSA system. The implants were un-modified, geometric algorithms were used to identify the femoral component.

Results: The BHR femoral component showed no significant displacement from its immediate post-operative position. All components of migration showed no significant displacement in any direction, at 1 or 2 years.

Conclusion: The BHR femoral component does not migrate significantly within the first two post-operative years. Its’ migration compares favourably to other designs of femoral component. The BHR is therefore likely to remain stable in the future, as the majority of implant migration occurs within the first two years.


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 7 | Pages 921 - 927
1 Jul 2005
Glyn-Jones S Gill HS Beard DJ McLardy-Smith P Murray DW

Polished, tapered stems are now widely used for cemented total hip replacement and many such designs have been introduced. However, a change in stem geometry may have a profound influence on stability. Stems with a wide, rectangular proximal section may be more stable than those which are narrower proximally. We examined the influence of proximal geometry on stability by comparing the two-year migration of the Exeter stem with a more recent design, the CPS-Plus, which has a wider shoulder and a more rectangular cross-section. The hypothesis was that these design features would increase rotational stability.

Both stems subsided approximately 1 mm relative to the femur during the first two years after implantation. The Exeter stem was found to rotate into valgus (mean 0.2°, sd 0.42°) and internally rotate (mean 1.28°, sd 0.99°). The CPS-Plus showed no significant valgus rotation (mean 0.2°, sd 0.42°) or internal rotation (mean −0.03°, sd 0.75°). A wider, more rectangular cross-section improves rotational stability and may have a better long-term outcome.


Orthopaedic Proceedings
Vol. 87-B, Issue SUPP_I | Pages 71 - 71
1 Mar 2005
Belthur M Moras P Jones S Fernandes J
Full Access

Aim: To evaluate our results of articulated hip distraction in children with a painful, stiff hip.

Materials & Methods: Between 1988 & 2003, 10 children underwent hip distraction and 7 have completed treatment. The diagnoses were varied, though the presentations were those of pain & stiffness of the hip, poor posture and gait. The Orthofix articulated hip device was used in all patients. The outcome assessment was performed by clinical and radiological review.

Results: The mean age of the patients was 13.7 years (Range 12–17 years). The primary diagnosis was SUFE- 3, Perthes-4, trauma-1, septic arthritis -1, chemotherapy induced -1. The mean fixator time was 12 weeks (range 10–14 weeks). The follow-up period ranged from 4–183 months. Soft tissue releases and joint debridement were done in 6 and 2 patients respectively. Results were good in one, fair in five and poor in one patient. Patients with non-functional ankylosis gained functional position with some increase in range of motion. Grade 2 pin tract infections were noted in 4 patients.

Conclusion: Early results with hip distraction in this difficult, complicated group of patients are promising clinically and radiologically.


The Journal of Bone & Joint Surgery British Volume
Vol. 86-B, Issue 6 | Pages 830 - 836
1 Aug 2004
Jones S Al Hussainy HA Ali F Betts RP Flowers MJ

We prospectively reviewed 24 patients (35 feet) who had been treated by a Scarf osteotomy and Akin closing-wedge osteotomy for hallux valgus between June 2000 and June 2002. There were three men and 21 women with a mean age of 46 years at the time of surgery. The mean follow-up time was 20 months.

Our results showed that 50% of the patients were very satisfied, 42% were satisfied, and 8% were not satisfied. The mean American Orthopaedic Foot and Ankle Society score improved significantly from 52 points pre-operatively to 89 at follow-up (p < 0.001).

The intermetatarsal and hallux valgus angles improved from the mean pre-operative values of 15° and 33° to 9° and 14°, respectively. These improvements were significant (p < 0.0001). The change in the distal metatarsal articular angle was not significant (p = 0.18).

There was no significant change in the mean pedobarographic measurements of the first and second metatarsals after surgery (p = 0.2). The mean pedobarographic measurements of the first and second metatarsals at more than one year after surgery were within the normal range.

Two patients had wound infections which settled after the administration of antibiotics. One patient had an intra-operative fracture of the first metatarsal and one required further surgery to remove a long distal screw which was irritating the medial sesamoids.

We conclude that the Scarf osteotomy combined with the Akin closing-wedge osteotomy is safe and effective for the treatment of hallux valgus.


Orthopaedic Proceedings
Vol. 86-B, Issue SUPP_IV | Pages 403 - 403
1 Apr 2004
Glyn-Jones S Gill H Murray D
Full Access

Introduction: This study investigates the influence of surgical approach on the early migration of a cemented Total Hip Replacement (THR), assessed by Roentgen Stereo-photogrammetric Analysis (RSA). Rapid early migration has been correlated with premature implant failure.

Method: 46 patients awaiting THR were allocated into Posterior Approach (PA) and Lateral Approach (LA) groups. RSA was used to assess post-operative stem position and migration at 1 year. Post-operative gait was examined for a subgroup of patients.

Results: There was no difference in initial stem position within the medulla. Significant differences in distal migration were found; (LA 0.78±0.07mm and PA 1.27±0.15mm), p< 0.01. Posterior head migration for the PA group (0.78±0.18mm) was twice that for the LA group (0.46±0.08mm), p< 0.05. The PA group showed greater medial migration of the prosthesis tip (0.62±0.24mm), compared to the LA group (0.11±0.08mm), p< 0.05. During gait, the legs of the PA group were relatively internally rotated when compared to those of the LA group.

Discussion: The PA implants rotate internally and into valgus further than the LA implants. The starting positions of the prostheses were the same with similar cement and prostheses characteristics. We can infer that surgical approach and therefore muscle function have a significant effect upon component migration. During gait, the PA group has relatively internally rotated legs, probably due to short external rotator weakness. Hence, the internally rotating torque on the femoral stem will be larger, explaining the rapid migration in this direction. With the LA approach, the abductors are likely to be damaged. Therefore, the PA joint reaction force will be more laterally directed, explaining the higher coronal plane rotation rates seen in this group.

Conclusion: Profound differences exist in early migration, between the LA and PA. Different muscle function may account for this and probably influences long-term outcome.


Orthopaedic Proceedings
Vol. 86-B, Issue SUPP_III | Pages 356 - 356
1 Mar 2004
Jones S Hosalkar H Hartley J Tucker A Hill R
Full Access

Aim: We present a review on RSD in children and emphasise the role of multidisciplinary team approach in the management of 13 children. Method: 3 boys and 10 girls with a mean age of 13 years and 4 months were reviewed before and after treatment. They were assessed for pain (visual analogue score) and function. A team-care approach was utilised and co-ordinated by the Orthopaedic Surgeon. Other members included a physiotherapist, clinical psychologist and the pain care team. Results: All the patients received physical therapy (land and hydrotherapy). 5 patients received guanethidine blocks and 10 required psychological support. The time to diagnosis ranged from 2 to 11 months. All the patients improved over a period of 2.5–7 months. Conclusion: Early diagnosis with aggressive multidisciplinary goal oriented team approach should form the basis of management in children with RSD.


Orthopaedic Proceedings
Vol. 86-B, Issue SUPP_III | Pages 328 - 328
1 Mar 2004
Ali F Dewnany G Ali A Abdslam K Jones S Bell M
Full Access

The treatment of acetabular dysplasia in adolescents (age> 12) is difþcult and various complex pelvic osteotomies have been described. The aim of surgery being improvement in pain and to delay the onset of secondary osteoarthrosis. Methods: We present our experience of using the Tonnis triple pelvic osteotomy for treatment of acetabular dysplasia in the adolescent and adult age groups (range 13–27 years). This retrospective analysis includes 25 patients operated on over a nine year period (1991–2000) with an average followup of four years (range 2–8 years). More than 50% of the patients had had a previous open reduction or femoral osteotomy for CDH. Results: Radiographic analysis (pre & post op) included CE angle of Wiberg, Sharp-Ullmann index and the acetabular angle of the weight bearing zone. All parameters showed an improvement in the post operative analysis with an improvement in pain and range of movement in all patients. Discussion: The Tonnis triple pelvic osteotomy has the advantage of allowing the operator a direct þeld of view at all times and achieving a great deal of lateral rotation and medial displacement of the acetabulum due to the proximity of the osteotomy to the acetabulum. The ischial ramus and its ligaments to the sacrum are left intact, leading to greater stability of the pelvis and spine. Conclusion: Though technically difþcult and needing a long learning curve, it does improve acetabular alignment and symptoms in the early postoperative years. However long term studies are required to document its effect on the rate of secondary osteoarthrosis.


Orthopaedic Proceedings
Vol. 86-B, Issue SUPP_III | Pages 260 - 261
1 Mar 2004
Glyn-Jones S Gill H McLardy-Smith P Murray D
Full Access

Aim: Small amounts of subsidence may be beneficial in stabilising a stem & appears to be a featue of polished tapered stems. Stem rotation (measured as posterior head migration) within the cement mantle, however, is probably a more important mechanism of failure than subsidence. Stems with a wider proximal portion are thought to better resist rotation. The CPS (Endoplus, UK) is such a device; here we compare its’ stability with that of the Exeter (Stryker-Howmedica, UK). Method: 20 patients received the CPS-plus stem & underwent RSA examinations at 3, 6 & 12 months postoperatively. The Exeter 1 year migration data (32 hips) was used as a comparison. Both groups underwent a Hardinge approach & the prosthesis was secured with CMW3G cement. Results: Both stems subsided about 1mm. The CPS showed less medio-lateral & A-P movement of the proximal stem than the Exeter over 1 year, as shown below: 1 Year Mean Migration ± SEM (mm) Discussion: The CPS internally rotates less than the Exeter, as demonstrated by the smaller amount of posterior head migration. It has a lateral flare of the shoulder; making its’ cross-section wider than the Exeter’s, this probably produces a greater resistance to rotation. The CPS also undergoes less medio-lateral proximal stem migration. Its’ lateral shoulder flare is probably responsible for this axial subsidence, as it prevents the shoulder from moving laterally whilst subsiding onto the calcar.

Increasing the width of the proximal section of a polished tapered stem enhances its rotational stability.


Orthopaedic Proceedings
Vol. 86-B, Issue SUPP_III | Pages 315 - 315
1 Mar 2004
Hussainy HA Jones S Ali F Flowers M
Full Access

Aim: The purpose of this prospective study was to assess the outcome of scarfe osteotomy for hallux valgus. Method: 26 patients were reviewed but only the results of 24 patients (33 osteotomies) were available for analysis. The assessment involved the American Academy Foot and Ankle Society Score, pedobarographic & radiographic examination.

There were 3 male and 21 female patients with a mean age of 46 years. The mean follow up was 17 months. Statistical analysis was carried out. Results: The AAFAS score improved from a mean preoperative value of 52 to 89 postoperatively. The mean improvement was 34 (range 12–46). The inter-metatarsal and hallux valgus angles improved from a mean preoperative value of 15 and 31 degrees respectively to a mean postoperative value of 8 and 14 degrees. 22 patients (91.6%) were satisþed with the outcome of surgery. The pedobarographic results will be illustrated. In one patient a fracture occurred intra-operatively and two patients had wound infection which settled with antibiotics. Conclusion: The early results of the scarfe osteotomy for hallux valgus in our hands are encouraging.


The Journal of Bone & Joint Surgery British Volume
Vol. 86-B, Issue 2 | Pages 172 - 176
1 Mar 2004
Glyn-Jones S Gill HS McLardy-Smith P Murray DW

The Birmingham hip resurfacing (BHR) arthroplasty is a metal-on-metal prosthesis for which no medium- or long-term results have been published. Despite this, it is increasing in popularity as an alternative to stemmed prostheses for younger patients. Since the fixation of the socket is conventional, the major concern is long-term failure of the femoral component. This can be predicted by the use of roentgen stereophotogrammetric analysis (RSA). We have therefore undertaken such a study of the BHR femoral component over a period of two years.

Twenty patients (22 hips) underwent a standard BHR procedure. Migration of the femoral component was measured by RSA at intervals of three, six, 12 and 24 months. At 24 months the total three-dimensional migration of the head was 0.2 mm. This was not statistically significant. Previous studies have shown that implants which loosen quickly have rapid early migration. Our results therefore suggest that the BHR femoral component is an inherently stable device which is likely to perform well in the long term.


Orthopaedic Proceedings
Vol. 86-B, Issue SUPP_I | Pages 6 - 7
1 Jan 2004
Jones S Ganapathi M Roberts P
Full Access

The use of exhaust suit systems is commonplace in arthroplasty surgery where isolation of the surgical team is desirable in an attempt to reduce the risk of infection transmission. Elevated carbon dioxide levels have been reported in the non-clinical setting with such systems the consequences of which can include fatigue, diapho-resis, nausea, headache and irritability.

The aim of our study was to determine the levels of carbon dioxide present within an exhaust suit system during hip arthroplasty and to compare these with the recommended occupational exposure limit levels published by the Health and Safety Executive (HSE).

Data was collected during ten primary hip replacements performed by the same surgeon whilst wearing the Stryker Steri-Shield Helmet Exhaust System. This is a self-contained unit with an integrated blower used in conjunction with a full-length gown. In addition the helmet was fitted with an air-sampling probe connected to a portable infrared CO2 monitor and also a temperature probe. Thus continuous monitoring of both CO2 and temperature level during surgery was possible.

The mean initial CO2 concentration in the helmet at the beginning of surgery was 3 000 parts per million (ppm) and the mean maximum CO2 level recorded was 13 000 ppm. The mean time the surgeon was within an exhaust suit to perform a primary hip replacement was 1 hr 54 mins and for 86% of this time period the CO2 level within the helmet exceeded the recommended level of 5 000 ppm as stipulated by the HSE.

In conclusion we have demonstrated significantly elevated CO2 levels within the Stryker Steri-shield Exhaust Suit System during hip surgery. Surgeons who use this system should be aware of this together with the physical symptoms that may result.


Orthopaedic Proceedings
Vol. 86-B, Issue SUPP_I | Pages 19 - 19
1 Jan 2004
Glyn-Jones S Gill H McLardy-Smith P Murray D
Full Access

The relative motion between a prosthesis, the cement mantle and its’ host bone during weight bearing is not well understood. Using Radiostereophotogrammetric Analysis (RSA), we examined the dynamically inducible micromotion that exists at these interfaces when an increased load is placed through the prosthesis.

Dynamically inducible micromotion was measured in the femoral components of 21 subjects undergoing total hip replacement with polished Exeter stems. Two standing RSA studies were performed, at 3 and 12 months postoperatively. Firstly in double-leg stance, and secondly fully weight bearing through the operated hip.

Subjects had no signs of clinical or radiological signs of loosening at 1 year. Significant micromotion was detected at the prosthesis-cement interface at 3 months.

Similar patterns of micromotion were observed at 12 months. The prosthesis appeared to bend during single-leg stance weight bearing, however this accounted for less than half of the total observed movement.

Conventional RSA studies were conducted at 3 months, 6 months and 1 year to confirm that the implants showed normal migration patterns.

This study demonstrates that movement exists between the prosthesis and bone during cyclical weight bearing. This dynamically inducible micromotion probably occurs at the prosthesis-cement interface. It could account for the wear that is observed on the surface of retrieved secure prostheses. This may be a mechanism by which failure eventually occurs.


Orthopaedic Proceedings
Vol. 86-B, Issue SUPP_I | Pages 19 - 19
1 Jan 2004
Glyn-Jones S Gill H McLardy-Smith P Murray D
Full Access

The Birmingham reSurfacing Arthroplasty (BSA) is a metal on metal prosthesis with no published independent clinical studies. Despite this, it is increasing in popularity, especially as an alternative to stemmed prostheses in younger patients. This study presents the 1year migration results of the BSA femoral component using Roentgen Stereophotogrammteric Analysis (RSA).

Twenty six subjects underwent a BSA, through the postero-lateral approach using CMW3G cement, with RSA marker balls placed intra-operatively. The femoral component migration was measured at intervals of 3, 6 and 12 months using the Oxford RSA system. Geometric algorhythms were used to identify the femoral component. The data was examined for distribution prior to analysis. All statistical analysis was performed using the t-test.

The data was normally distributed. The 1 year migration results of the BSA femoral component are displayed below.

All cemented implants migrate in vivo. The majority of cemented stemmed implant migration occurs within the first post-operative year. High rates of migration within the first post-operative year correlate with premature component failure in some instances. The BSA is a fundamentally different design to most cemented prostheses, despite this we know that very large migrations, those in excess of 2mm/year in any direction are generally regarded as poor indicators of long term outcome. These results suggest that the BSA femoral component is an inherently stable device as it does not migrate significantly within the first post-operative year. Only long-term independent clinical studies and continued RSA follow-up will enable a comprehensive evaluation of the device.


The Journal of Bone & Joint Surgery British Volume
Vol. 85-B, Issue 4 | Pages 565 - 571
1 May 2003
Jones S Hosalkar HS Hill RA Hartley J

We have treated seven children with relapsed infantile Blount’s disease by elevation of the hemiplateau using the Ilizarov frame.

Three boys and four girls with a mean age of 10.5 years were reviewed at a mean of 29 months after surgery. All had improved considerably and were pleased with the results. The improvements in radiological measurements were statistically significant (p < 0.001). Three-dimensional CT reconstruction was useful for planning surgery. There were no major complications. The advantages of this technique are that in addition to elevation of the hemiplateau, rotational deformities and limb-length discrepancies may be addressed.


The Journal of Bone & Joint Surgery British Volume
Vol. 85-B, Issue 2 | Pages 261 - 264
1 Mar 2003
Hosalkar HS Jones S Chowdhury M Hartley J Hill RA

We review the results of a modified quadricepsplasty in five children who developed stiffness of the knee after femoral lengthening for congenital short femur using an Ilizarov external fixator which spanned the knee.

All had a full range of movement of the knee before lengthening was undertaken. Unifocal lengthening was carried out in the distal metaphysiodiaphyseal region of the distal femur with a mean gain of 6.5 cm. The mean percentage lengthening was 24%.

At the end of one year after removal of the Ilizarov frame and despite intensive physiotherapy all patients had stiffness. Physiotherapy was continued after the quadricepsplasty and, at the latest follow-up (mean 27 months), the mean active flexion was 102° (80 to 130). The gain in movement ranged from 50° to 100°. One patient had a superficial wound infection which settled after a course of oral antibiotics. None developed an increased extension lag after surgery and all were very satisfied with the results. Quadricepsplasty is a useful procedure for stiffness of the knee after femoral lengthening which has not responded to physiotherapy.


Orthopaedic Proceedings
Vol. 85-B, Issue SUPP_II | Pages 162 - 162
1 Feb 2003
Jones S Hosalkar H Hartley J Tucker A Hill R
Full Access

Reflex sympathetic dystrophy is a syndrome characterised by pain and hyperaesthesia associated with swelling, vasomotor instability and dystrophic changes of the skin. It is rare in children, can occur without any previous history of significant trauma and may be recurrent and migratory.

We reported 13 new cases of RSD in children and emphasised the role of a multidisciplinary team approach in management. A review of the literature was included.

13 children (3 boys and 10 girls) with reflex sympathetic dystrophy were presented. They were aged between 8 and 17 years. Mean age at onset was 13 years 4 months. All of them had RSD involving the lower limbs. Thermography was performed in 10 cases. The average time to correct diagnosis was 4 months. Five ankles, 4 knees and 5 hips were involved (14 joints in 13 cases). Psychological assessments revealed abnormalities in all cases. Pain (visual analogue score) and function were assessed before and after treatment.

The most common therapy in children is progressive mobilisation supported by analgesic drugs, psychological and physical therapy. We individualised the therapy for each child. A team-care approach with the physiotherapist, psychologist and pain-care team co-ordinated by the Orthopaedic Consultant was the essence of our management. All children received physical therapy including a wide variety of non-standarised approaches involving analgesics and hydrotherapy. 5 patients received guanithidine blocks. Individual therapy was monitored with set achievable goals and weekly assessment of progression of mobility and joint motion.

Time from the first RSD episode to resolution averaged 6 months in our series [it was mean 10 weeks in the non-adolescent cases (8 cases) and 7 months in the adolescent one (5 cases)]. The pain and function scores improved remarkably in all patients.

RSD in children is not a widely recognised condition. There is often a delay in diagnosis in view of the rarity of the condition as well as the fact that specific diagnostic modalities are not readily available in all centres. Psychological factors should not be underestimated. Early diagnosis with an aggressive, multidisciplinary, monitored, ‘goal-oriented’ team approach should be the basis of management in these cases.


Orthopaedic Proceedings
Vol. 85-B, Issue SUPP_II | Pages 179 - 179
1 Feb 2003
Ali F Ali A Davies M Genever A Hashmi M Jones S McAndrew A Bruce A Howard A
Full Access

This study was designed to assess the standard of orthopaedic training of Senior House Officers in the U.K. and to determine the optimum time that should be spent in these posts before registrar training.

Two MCQ papers were constructed. One for the pre test and one for the post test. Questions covered all aspects of orthopaedics and trauma including operative surgery. The paper was firstly tested on controls including medical students, house officers, registrars of various grades and consultants. There was no statistical difference in the results for the two papers within the groups indicating that pre and post test papers were of similar standard. In addition the average scores in the tests increased proportionately to the experience and grade of the control.

129 SHOs from 25 hospitals in 10 different regions were tested by MCQ examination at the beginning of their 6-month post. They were again tested at the end of the job. The differences in score were compared. This difference was then correlated with the experience and career intention of the SHO.

There was no statistical difference between pre and post test results in all groups of SHOs in the study (student t test). The best improvement in scores during this six month period were seen in SHOs of 1–1.5 years orthopaedic experience. SHOs of more than 3 years experience demonstrated the smallest improvement in their score. There was a net loss of seven trainees with a career intention of orthopaedics to other disciplines.

In the vast majority of Senior House Officer posts in this country, very little seems to be learnt during a six-month attachment. This is especially so for those who are doing orthopaedics for the first time as well as very experienced SHOs.


Orthopaedic Proceedings
Vol. 85-B, Issue SUPP_II | Pages 166 - 166
1 Feb 2003
Reed M Brooks H Sher J Emmerson K Jones S Partington P
Full Access

To determine whether resection of osteophyte at TKR improves movement, 139 TKRs were performed on knees with pre-operative posterior osteophyte. Randomisation was to have either resection of distal femoral osteophyte guided by a custom made ruler or no resection. After preparation of the femoral bone cuts the ruler measuring 19 mm was placed just proximal to the posterior chamfer cut. The proximal end of this ruler marked the bone to be resected and this was performed using an osteotome at 45 degrees. Knees randomised to no resection had no further femoral bony cuts. Three months after implantation the patients had range of motion assessed.

One hundred and fourteen suitable knees were assessed, with 59 knees (57 patients) in the resection group and 55 knees (54 patients) in the no resection group. Full extension was more likely in the resection group (62%) than the group without resection (41%)(p=0.08). Flexion to at least 110 degrees was, however, less in the resection group (37%) than the no resection group (54%) (p=0.09).

Our study failed to show a statistically significant difference if the bony osteophyte is removed. There were however sharp trends, with statistically a one in ten chance these results would be different if the trial was repeated. Although there is no indication as to the cause of improved extension this could be explained by the release of the posterior capsular structures allowing full extension. The reduction in flexion is harder to explain and this may be due to increase in perioperative trauma and resultant swelling, possibly with fibrosis. Range of movement, particularly flexion, is known to improve up to 1 year post-operatively and assessment of these groups at that stage would be beneficial.


Orthopaedic Proceedings
Vol. 85-B, Issue SUPP_II | Pages 160 - 160
1 Feb 2003
Jones S Hosalkar H Hill R Hartley J
Full Access

We present the results of treatment for relapsed infantile Blounts disease using a technique of hemiplateau elevation with the Ilizarov frame.

7 patients with a mean age of 10 years 6 months were reviewed at 30 months following hemiplateau elevation with/without ipsilateral tibial lengthening. Preoperatively clinical photographs, long leg standing radiographs and 3D computed tomography images were acquired. The patients were evaluated clinically (presence of knee pain, range of knee motion, knee stability and leg length discrepancy) and radiologically. Schoeneckers objective assessment was undertaken. The results were analysed statistically.

Clinically all the patients improved significantly. No patient had knee pain and the range of knee motion was from 0° to more than 100° of knee flexion. The radiological results and Schoeneckers grading are depicted below.

The improvement in radiological measurements were statistically significant. Pin site infection was present in all but settled with antibiotics.

The results of hemiplateau elevation for relapsed infantile Blounts disease are encouraging.


Orthopaedic Proceedings
Vol. 85-B, Issue SUPP_I | Pages 8 - 9
1 Jan 2003
Glyn-Jones S Gill H Murray D
Full Access

This study examined the effect of surgical approach on the 1year migration of the Exeter stem, using Roentgen Stereophotogrammetric Analysis (RSA). There is evidence that implants with increased early migration, particularly those moving into internal rotation, are likely to have a higher failure rate.

A total of 46 patients awaiting THR were allocated into 2 groups. Both groups underwent an Exeter Total Hip replacement, one through the Posterior Approach (PA), and the other through the Hardinge Approach (HA). RSA was used to assess post-operative stem position and migration at 1 year. Post-operative gait analysis and clinical evaluation was used to assess a subgroup of patients.

There was no difference in the initial stem position of each group within the femoral canal. Significant differences in migration were found for migration of the head distally and posteriorly and for the tip medially. During gait, the legs of the PA group were relatively internally rotated when compared to those of the HA group. Relative to the supporting bone, the PA implants internally rotate and also rotate into valgus further than the HA implants. The starting position of the prostheses was the same and the cement and prosthesis characteristics were similar. From this, we can infer that surgical approach and therefore muscle function, have a large influence on component migration. During gait, the PA group had internally rotated legs compared to the HA group. This is probably due to short external rotator weakness in the PA group. As a result the internally rotating component of the posteriorly directed joint reaction force on the femoral stem will be larger. This probably explains the rapid internal rotation seen in the implants of the PA group. With the HA group, because of abductor damage there is likely to be a smaller component of the joint reaction force acting on the stem. This would explain the smaller rates of observed coronal plain rotation (rotation into valgus).

Profound differences exist in early migration, between the HA and PA. Different muscle function may account for this and probably influences long-term outcome.


Orthopaedic Proceedings
Vol. 85-B, Issue SUPP_I | Pages 62 - 62
1 Jan 2003
Glyn-Jones S Gill HS McLardy-Smith P Murray DW
Full Access

This early study examines the influence of a wider shoulder on the 1 year migration of a cemented, polished, tapered stem, using RSA.

Polished, tapered stems (PTS) have excellent 10 year survival rates. RSA studies have demonstrated that these devices subside about 1 mm / year. Small amounts of subsidence are beneficial in stabilising a stem. Stem rotation (measured as posterior head migration) within the cement mantle is probably a more important mechanism of failure than subsidence. Stems with a wider proximal portion are thought to better resist rotation. The CPS (Endoplus, UK) is such a device; here we compare its’ stability with that of the Exeter.

20 patients received the CPS-plus stem and underwent RSA examinations at 3, 6 and 12 months postoperatively. The Exeter 1 year migration data was used as a comparison. Both groups underwent a Hardinge approach with CMW3G cement.

Both stems subsided about 1mm. The CPS showed less medio-lateral and A-P movement of the proximal stem than the Exeter over 1 year, as shown below:

The CPS internally rotates less than the Exeter, as demonstrated by the smaller amount of posterior head migration. It has a lateral flare of the shoulder; making its cross-section wider than the Exeter’s, this probably accounts for its’ greater resistance to rotation. The CPS also undergoes less medio-lateral proximal stem migration. Its’ lateral shoulder flare is probably responsible for this axial subsidence, as it prevents the shoulder from moving laterally whilst subsiding over the calcar.

A PTS with a broad proximal section is more stable, this may confer an increased survival advantage.


Orthopaedic Proceedings
Vol. 84-B, Issue SUPP_II | Pages 160 - 160
1 Jul 2002
Kumar A Jones S Redman P Taggert T Bickerstaff
Full Access

Purpose: To determine if it is necessary to assess instability of the chronic anterior cruciate ligament deficient knee under general anaesthesia.

Materials and methods: 27 anterior cruciate ligament deficient knees in 27 patients were evaluated both subjectively using the Lachmanns and pivot shift test and objectively using the KT 1000 arthometer. This was done in the preoperative clinic (without the patient anaesthetised) and subsequently in the anaesthetic room with the patient anaesthetised (under general anaesthesia) prior to anterior cruciate ligament reconstruction. The data was prospectively collected. Only data on 21 knees was available for analysis. There were 20 females and one male with an average age of 29 years.

Results: There was no statistical significant difference (using students T test) between the data collected using the KT 1000 arthometer with and without the patient anaesthetised.

A significant difference was noted both for the Lachmanns (p< 0.01) and pivot shift test (p< 0.001) between the results obtained with and without anaesthesia. This however did not change the management.

Conclusion: Assessing the chronic anterior cruciate ligament deficient knee using the KT 1000 arthrometer, Lachmann and pivot shift test under general anaesthesia is not necessary if these assessments have been carried out in clinic.


The Journal of Bone & Joint Surgery British Volume
Vol. 83-B, Issue 4 | Pages 619 - 621
1 May 2001
ALI F JONES S SHELBROOKE K


The Journal of Bone & Joint Surgery British Volume
Vol. 82-B, Issue 8 | Pages 1204 - 1204
1 Nov 2000
JONES S ALI F FERNDANDES J


The Journal of Bone & Joint Surgery British Volume
Vol. 82-B, Issue 7 | Pages 1085 - 1085
1 Sep 2000
JONES S ALI F FERNDANDEZ J


The Journal of Bone & Joint Surgery British Volume
Vol. 74-B, Issue 1 | Pages 18 - 22
1 Jan 1992
Jones S Pinder I Moran C Malcolm A

Isolated wear of the polyethylene tibial component led to failure in five of a series of 108 uncemented porous-coated knee replacements. The clinical features included pain, effusion and instability with progressive varus deformity. In all cases there was extensive wear on the medial side of the polyethylene surface of the prosthesis. The mechanism of such wear is complex, being due in part to the unconstrained nature of the joint and the incongruity of its surfaces. Other design characteristics may have contributed.


The Journal of Bone & Joint Surgery British Volume
Vol. 73-B, Issue 3 | Pages 487 - 491
1 May 1991
Forbes H Allen P Waller C Jones S Edgar M Webb P Ransford A

Since 1981, during operations for spinal deformity, we have routinely used electrophysiological monitoring of the spinal cord by the epidural measurement of somatosensory evoked potentials (SEPs) in response to stimulation of the posterior tibial nerve. We present the results in 1168 consecutive cases. Decreases in SEP amplitude of more than 50% occurred in 119 patients, of whom 32 had clinically detectable neurological changes postoperatively. In 35 cases the SEP amplitude was rapidly restored, either spontaneously or by repositioning of the recording electrode; they had no postoperative neurological changes. One patient had delayed onset of postoperative symptoms referrable to nerve root lesions without evidence of spinal cord involvement, but there were no false negative cases of intra-operative spinal cord damage. In 52 patients persistent, significant, SEP changes were noted without clinically detectable neurological sequelae. None of the many cases which showed falls in SEP amplitude of less than 50% experienced neurological problems. Neuromuscular scoliosis, the use of sublaminar wires, the magnitude of SEP decrement, and a limited or absent intra-operative recovery of SEP amplitude were identified as factors which increased the risk of postoperative neurological deficit.


The Journal of Bone & Joint Surgery British Volume
Vol. 69-B, Issue 2 | Pages 338 - 338
1 Mar 1987
Horsfield D Jones S


The Journal of Bone & Joint Surgery British Volume
Vol. 65-B, Issue 2 | Pages 134 - 139
1 Mar 1983
Jones S Edgar M Ransford A Thomas N

An electrophysiological system for monitoring the spinal cord during operations for scoliosis is described. During the development of the technique the recording of cortical somatosensory evoked potentials from the scalp and spinal somatosensory evoked potentials from the laminae or spines was superseded by the positioning of recording electrodes in the epidural space cephalad to the area to be fused. All recordings were made in response to stimulation of the posterior tibial nerve at the knee. Results in 138 patients are presented and the findings in three patients who exhibited neurological deficits after operation are described. It is concluded that spinal somatosensory evoked potentials are sensitive to minor spinal cord impairment, possible due to ischaemia, and that these changes may be reversed when the cause is quickly remedied. The monitoring system interferes minimally with anaesthetic and surgical procedures and is now performed as a routine.


The Journal of Bone & Joint Surgery British Volume
Vol. 62-B, Issue 4 | Pages 492 - 496
1 Nov 1980
Landi A Copeland S Parry C Jones S

In 15 patients who underwent open exploration of the brachial plexus, the somatosensory evoked potentials and nerve action potentials recorded at the time of operation were useful as guides to the most appropriate surgical procedure, and also in predicting the outcome in certain lesions. In three patients the apparent normality of the upper trunk of the plexus was concealing a more proximal lesion which was irrecoverable. The presence of a somatosensory evoked potential showed functional continuity in three patients in whom the C7 root was clinically involved and who recovered after operation. In five patients proximal stumps of ruptured C5 roots showed functional central continuity; this indicated their suitability for grafting. These patients recovered except one who suffered from co-existing disease. The electrophysiological studies also confirmed the clinical diagnosis of avulsion of the C8 and T1 roots and therefore prevented unnecessary dissection.