To preserve knee function and reduce degenerative, meniscal tears should be repaired where possible. Meniscal wrapping with collagen matrices has shown promising clinical outcome (AAOS meniscal algorithm), however there is limited basic science to support this. to model the contact pressures on the human tibial plateau beneath a (1) a repaired radial meniscal tear and (2) a wrapped and repaired radial meniscal tear.Abstract
INTRODUCTION
AIM
Conventional proximal tibial osteotomy is a widely successful joint-preserving treatment for osteoarthritis; however, conventional procedures do not adequately control the posterior tibial slope (PTS). Alterations to PTS can affect knee instability, ligament tensioning, knee kinematics, muscle and joint contact forces as well as range of motion. This study primarily aimed to provide a comprehensive investigation of the variables influencing PTS during high tibial osteotomy using a 3D surgical simulation approach. Secondly, it aimed to provide a simple means of implementing the findings in future 3D pre-operative planning and /or clinically. The influence of two key variables: the gap opening angle and the hinge axis orientation on PTS was investigated using three independent approaches: (1) 3D computational simulation using CAD software to perform virtual osteotomy surgery and simulate the post-operative outcome. (2) Derivation of a closed-form mathematical solution using a generalised vector rotation approach (3) Clinical assessment of synthetically generated x-rays of osteoarthritis patients (n=28; REC reference: 17/HRA/0033, RD&E NHS, UK) for comparison against the theoretical/computational approaches. The results from the computational and analytical assessments agreed precisely. For three different opening angles (6°, 9° and 12°) and 7 different hinge axis orientations (from −30° to 30°), the results obtained were identical. A simple analytical solution for the change in PTS, ΔPs, based on the hinge axis angle, α, and the osteotomy opening angle, θ, was derived: ΔPs=sin-1(sin α sin θ) The clinical assessment demonstrated that the absolute values of PTS, and changes resulting from various osteotomies, matched the results from the two relative prediction methods. This study has demonstrated that PTS is impacted by the hinge axis angle and the extent of the osteotomy opening angle and provided computational evidence and analytical formula for general use.
High tibial osteotomy (HTO) is an effective surgical treatment for isolated medial compartment knee osteoarthritis; however, widespread adoption is limited due to difficulty in achieving the planned correction, and patient dissatisfaction due to soft tissue irritation. A new HTO system – Tailored Osteotomy Knee Alignment (TOKA®, 3D Metal Printing Ltd, Bath, UK) could potentially address these barriers having a custom titanium plate and titanium surgical guides featuring a unique mechanism for precise osteotomy opening as well as saw cutting and drilling guides. The aim of this study was to assess the accuracy of this novel HTO system using cadaveric specimens; a preclinical testing stage ahead of first-in-human surgery according to the ‘IDEAL-D’ framework for device innovation. Local ethics committee approval was obtained. The novel opening wedge HTO procedure was performed on eight cadaver leg specimens. Whole lower limb CT scans pre- and post-operatively provided geometrical assessment quantifying the discrepancy between pre-planned and post-operative measurements for key variables: the gap opening angle and the patient specific surgical instrumentation positioning and rotation - assessed using the implanted plate. The average discrepancy between the pre-operative plan and the post-operative osteotomy correction angle was: 0.0 ± 0.2°. The R2 value for the regression correlation was 0.95. The average error in implant positioning was −0.4 ± 4.3 mm, −2.6 ± 3.4 mm and 3.1 ± 1.7° vertically, horizontally, and rotationally respectively. This novel HTO surgery has greater accuracy and smaller variability in correction angle achieved compared to that reported for conventional or other patient specific methods with published data available. This system could potentially improve the accuracy and reliability of osteotomy correction angles achieved surgically.
High tibial osteotomy for knee realignment is effective at relieving symptoms of knee osteoarthritis but the operation is surgically challenging. A new personalised treatment with simpler surgery using pre-operatively planned measurements from computed tomography (CT) imaging and 3D-printed implants and instrumentation has been designed and is undergoing clinical trial. The aim of this study was to evaluate the early clinical results of a preliminary pilot study evaluating the safety of this new personalised treatment. The single-centre prospective clinical trial is ongoing (IRCCS Istituto Ortopedico Rizzoli; IRB-0013355; ClinicalTrials.gov NCT04574570), with recruitment completed and all patients having received the novel custom surgical treatment. To preserve the completeness of the trial reporting, only surgical aspects were evaluated in the present study. Specifically, the length of the implanted osteosynthesis screws was considered, being determined pre-operatively eliminating intraoperative measurements, and examined post-operatively (n=7) using CT image processing (ScanIP, Synopsys) and surface distance mapping. The surgical time, patient discharge date and ease of wound closure were recorded for all patients (n=25).Abstract
Objectives
Methods
Additive manufacturing has led to numerous innovations in orthopaedic surgery: surgical guides; surface coatings/textures; and custom implants. Most contemporary implants are made from titanium alloy (Ti-6Al-4V). Despite being widely available industrially and clinically, there is little published information on the performance of this 3D printed material for orthopaedic devices with respect to regulatory approval. The aim of this study was to document the mechanical, chemical and biological properties of selective laser sintering (SLS) manufactured specimens following medical device (TOKA®, 3D Metal Printing LTD, UK) submission and review by the UK Medicines and Healthcare Products Regulatory Agency (MHRA). All specimens were additively manufactured in Ti-6Al-4V ELI (Renishaw plc, UK). Mechanical tests were performed according to ISO6892-1, ISO9585 and ISO12107 for tensile (n=10), bending (n=3) and fatigue (n=16) respectively (University of Bath, UK). Appropriate chemical characterisation and biological tests were selected according to recommendations in ISO10993 and conducted by external laboratories (Wickham Labs, UK; Lucideon, UK; Edwards Analytical, UK) in adherence with Good Lab Practise guidelines. A toxicological review was conducted on the findings (Bibra, UK).Abstract
Objectives
Methods
This matched cohort study aims to (a) assess differences in spinopelvic characteristics of patients having sustained a dislocation following THA and a control THA group without dislocation; (b) identify spinopelvic characteristics associated with risk of dislocation and; (c) propose an algorithm to define the optimum cup orientation for minimizing dislocation risk. Fifty patients with a history of THA dislocation (29 posterior-, 21 anterior dislocations) were matched for age, gender, body mass index, index diagnosis, and femoral head size with 100 controls. All patients were reviewed and underwent detailed quasi-static radiographic evaluations of the coronal- (offset; center-of-rotation; cup inclination/anteversion) and sagittal- reconstructions (pelvic tilt, pelvic incidence, lumbar lordosis, pelvic-femoral-angle, cup ante-inclination). The spinopelvic balance (PI-LL), combined sagittal index (CSI= Pelvic-femoral-angle + Cup Anteinclination) and Hip-User-Index were determined. sagittal index (CSI= Pelvic-femoral-angle + Cup Anteinclination) and Hip-User-Index were determined. Parameters were compared between the two groups (2-group analysis) and between controls and per direction of dislocation (3-group analysis). There were marginal coronal differences between the groups. Sagittal parameters (lumbar-lordosis, pelvic-tilt, CSI, PI-LL and Hip-User-Index) differed significantly. PI-LL (>10°) and standing pelvic tilt (>18°) were the strongest predictors of dislocation risk (sensistivity:70%/specificity:70%). All hips with a standing CSI<195° dislocated posteriorly and all with CSI>260° dislocated anteriorly. A CSI between 200–245° was associated with significantly reduced risk of dislocation (OR:6; 95%CI:2.5–15.0; p<0.001). In patients with unbalanced and/or rigid lumbar spine, standing CSI of 215–245° was associated with significantly reduced dislocation risk (OR:10; 95%CI:3.2–29.8; p<0.001). PI-LL and standing pelvic-tilt determined from pre-operative, standing, lateral spinopelvic radiograph can be useful screening tools, alerting surgeons of patients at increased dislocation risk. Measurement of the pelvic-femoral angle pre-operatively provides valuable information to determine the optimum, cup orientation associated with reduced dislocation risk by aiming for a standing CSI of 200–245°.
Ultra-High Molecular Weight Polyethylene (UHMWPE) can be made radiopaque through the diffusion of an oil-based contrast agent (Lipiodol Ultra-fluid). A similar process is used for Vitamin E incorporated polyethylene, which has a well-established clinical history. This study aimed to quantify the leaching of Lipiodol and compare to vitamin E polyethylene. GUR 1050 polyethylene (4 mm thickness) was cut into squares, 10 mm2. Samples (n=5) were immersed in 25 ml Lipiodol (Guerbet, France), or 15 ml Vitamin E (L-atocopherol, Sigma-Aldrich, UK). To facilitate diffusion, samples were held at 105°C for 18 hours. After treatment, all samples were immersed in DMEM (Sigma-Aldrich, UK) with Penicillin Streptomycin (Sigma-Aldrich, Kent, UK) at 4%v/v and held at 37°C in an incubator. Untreated polyethylene samples were included as controls. Leaching was quantified gravimetrically at weeks 2, 4 and 8. The radiopacity of the Lipiodol-diffused samples was investigated from µCT images (162kV, resolution 0.2 mm, X Tec, XT H 225 ST, Nikon Metrology, UK).Abstract
Objectives
Method
Oil-based fluids can be used to enhance the properties of polyethylene materials. For example, vitamin E infused polyethylene has a superior oxidation resistance and Lipiodol infused polyethylene has an enhanced X-ray attenuation. The aim of this study was to evaluate the long-term influence of oily fluid on the chemical, physical and tensile properties of polyethylene. An accelerated ageing procedure (an elevated temperature (80°C) for four weeks in air1) was used to investigate the oxidative stability (ASTM F2012-17)2, tensile (ISO 527)3 and thermal properties4 of oil treated polyethylene (n=5, GUR 1050, Celanese, Germany)and compared with clinically used polyethylene controls (oil-free standard and thermally treated polyethylene). All the experiments were performed on aged and unaged specimens in accordance to international standards and compared to currently available literature. A Kruskal-Wallis test was performed using a custom MATLAB code (R2017a, USA); with p < 0.05 considered statistically significant.Abstract
Objectives
Methods
Nearly a quarter of screws cause damage during insertion by stripping the bone, reducing pullout strength by over 80%. Studies assessing surgically achieved tightness have predominately shown that variations between individual surgeons can lead to underpowered investigations. Further to the variables that have been previously explored, several basic aspects related to tightening screws have not been evaluated with regards to how they affect screw insertion. This study aims to identify the achieved tightness for several variables, firstly to better understand factors related to achieving optimal intraoperative screw purchase and secondly to establish improved methodologies for future studies. Two torque screwdrivers were used consecutively by two orthopaedic surgeons to insert 60 cortical, non-locking, stainless-steel screws of 3.5 mm diameter through a 3.5 mm plate, into custom-made 4 mm thick 20 PCF sheets of Sawbone, mounted on a custom-made jig. Screws were inserted to optimal tightness subjectively chosen by each surgeon. The jig was attached to a bench for vertical screw insertion, before a further 60 screws were inserted using the first torque screwdriver with the jig mounted vertically, enabling horizontal screw insertion. Following the decision to use the first screwdriver to insert the remaining screws in the vertical position for the other variables, the following test parameters were assessed with 60 screws inserted per surgeon: without gloves, double surgical gloves, single surgical gloves, non-sterile nitrile gloves and, with and then without augmented feedback (using digitally displayed real-time achieved torque). For all tests, except when augmented feedback was used, the surgeon was blinded to the insertion torque. Once the stopping torque was reached, screws were tightened until the stripping torque was found, this being used to calculate tightness (stopping/stripping torque ratio). Screws were recorded to have stripped the material if the stopping torque was greater than the stripping torque. Following tests of normality, Mann-Whitney-U comparisons were performed between and combining both surgeons for each variable, with Bonferroni corrections for multiple comparisons. There was no significant (p=0.29) difference in the achieved tightness between different torque screw drivers nor different jig positions (p=0.53). The use of any gloves led to significant (p < 0 .001) increases in achieved tightness compared to not using gloves for one surgeon but made no difference for the other (p=0.38–0.74). Using augmented feedback was found to virtually eliminate stripping. For one surgeon average tightness increased significantly (p < 0 .001) when torque values were displayed from 55 to 75%, whilst for the other, this was associated with significantly decreases (p < 0 .001), 72 to 57%, both surgeons returned to their pre-augmentation tightness when it was removed. Individual techniques make a considerable difference to the impact from some variables involved when inserting screws. However, the orientation of screws insertion and the type of screwdriver did not affect achieved screw tightness. Using visual feedback reduces rates of stripping and investigating ways to incorporate this into clinical use are recommended. Further work is underway into the effect of other variables such as bone density and cortical thickness.
The resultant cup orientation depends upon the orientation of the pelvis at impaction. No studies to date have assessed whether patient-position during total hip arthroplasty (THA) has an effect on cup orientation. This study aims to 1) Determine the difference in pelvic position that occurs between surgery and radiographic, supine, post-operative assessment; 2) Examine how the difference in pelvic position influences subsequent cup orientation and 3) Establish whether pelvic orientation, and thereafter cup orientation, differences exist between THAs performed in the supine versus the lateral decubitus positions. This is a retrospective, multi-surgeon, single-centre, consecutive series. 321 THAs who had intra-operative, post-cup impaction, AP pelvic radiograph, in the operative position were included; 167 were performed with the patient supine (anterior approach), whilst 154 were performed in the lateral decubitus (posterior approach). Cup inclination/anteversion was measured from intra- and post-operative radiographs and the difference (Δ) was determined. Change in pelvic position (tilt, rotation, obliquity) between surgery and post-operatively was calculated from Δinclination/anteversion using the Levenberg-Marquardt algorithm.Introduction
Patients/Materials & Methods
Cervical spine fractures are frequent in impact sports, such as rugby union. The consequences of these fractures can be devastating as they can lead to paraplegia, tetraplegia and death. Many studies have been conducted to understand the injury mechanisms but the relationship between player cervical spine posture and fracture pattern is still unclear. The aim of this study was to evaluate the influence of player cervical spine posture on fracture pattern due to an impact load. Nineteen porcine cervical spines (C2 to C6) were dissected, potted in PMMA bone cement and mounted in a custom made rig. They were impacted with a mean load of 6 kN. Eight specimens were tested in an axial position, five in flexion and six in lateral bending. All specimens were micro-CT imaged (Nikon XT225 ST Scanner, Nikon Metrology, UK) before and after the tests, and the images were used to assess the fracture patterns. The injuries were classified according to Allen-Ferguson classification system by three independent observers. The preliminary results showed that the main fracture modalities were consistent with those seen clinically. The main fractures for the axial orientation were observed in C5-C6 level with fractures on the articular process and endplates. These findings support the concept that the fracture patterns are related to the spine position and give an insight for improvements on sports rules in order to reduce the risk of injury.
The screw fastening torque applied during bone fracture fixation has a decisive influence on subsequent bone healing. Insufficient screw tightness can result in device/construct instability; conversely, excessive torques risk damaging the bone causing premature fixation failure. This effect is even more prominent in osteoporotic bone, a condition associated annually with almost 9 million fractures worldwide. During fracture fixation, screw tightening torque is applied using subjective feel. This approach may not be optimal for patient”s recovery, increasing risk of fixation failure, particularly in osteoporotic bone, and potentially require revision surgical interventions. Besides bone density, various factors influence the performance of screw fixation. These factors include bone geometry, cortical thickness and time-dependant relaxation behaviour of the bone. If the influence of screw fastening torque on the bone and relationships between these factors was better understood, the surgical technique could be optimised to reduce the risk of complications. Within this study, we developed an axisymmetric finite element (FE) model of bone screw tightening incorporating viscoelastic behaviour of the cortical bone such as creep and stress relaxation. The model anticipated time-dependent behaviour of the bone for different bone thickness and density after a typical bone fixation screw had been inserted. The idealised model has been developed based on CT scans of bones with varying densities and inserted screws. The model was validated through a series of experiments involving bovine tibiae (4–5 months) to evaluate the evolution of surface strains with time (Ncorr v1.2). Stress distribution was assessed in photoelastic experiments using acrylic analogues. Relaxation tests have been performed in aqueous environment for up to 48 hours to ensure the relaxation would be complete. The creep behaviour (maximum principal strain) was compared against computational predictions. Our early simulations predicted relaxation strains on the surface of the bone to be 1.1% within 24 hours comparing favourably to 1.3% measured experimentally. Stress distribution patterns were in agreement with photoelastic results. Using experimentally derived viscoelastic properties, the model has the potential to predict creep and stress relaxation patterns after screw insertion with different fastening torques for bones with varying density and geometry. We aim to develop this into a planning tool providing guidance to surgeons for optimal tightening when using screw fixation, particularly in reduced quality bone.
A large proportion of the expense incurred due to hip fractures arises due to secondary factors such as duration of hospital stay and additional theatre time due to surgical complications. Studies have shown that the use of intramedullary (IM) nail fixation presents a statistically higher risk of re-fracture than plating, which has been attributed to the stress riser at the end of the nail. It is not clear, however, if this situation also applies to unstable fractures, for which plating has a higher fixation failure rate. Moreover, biomechanical studies to date have not considered newer designs of IM nails which have been specifically designed to better distribute weight-bearing loads. This aim of this experimental study was to evaluate the re-fracture risk produced by a newer type of nailing system compared to an equivalent plate. Experimental testing was conducted using fourth generation Sawbones composite femurs and X-Bolt IM hip nail (n=4) and fracture plate (n=4) implants. An unstable pertrochanteric fracture pattern was used (AO classification: 31-A1 / 31-A2). Loading was applied along the peak loading vector experienced during walking, up to a maximum load of 500N. The risk of re-fracture was evaluated from equivalent strains measured using four rosette strain gauges on the surface of the bone at known stress riser locations.Background
Methods
Numerical modelling using Finite Element (FE) Analysis has become ubiquitous in orthopaedic biomechanics, with both commercial and freely available packages widely used. Three FE packages in particular have gained popularity: Abaqus (Simulia); Ansys (ANSYS, Inc.) and FEBio (University of Utah). Although FEBio is now well established, its developers advise that comparisons should be made against more extensively tested software before trusting its results for specific problems. The aim of the study to conduct a comparison of mesh convergence and to provide validated open-source models of the femur for use all three FE packages. Three-dimensional FE models of the femur were created in Abaqus. To ensure that all aspects of the models were identical, custom scripts were developed to import the models into other packages. Mesh convergence studies were conducted for each solver using seven mesh densities for linear tetrahedral elements (up to 2 million). Experimental validation used fourth generation Sawbones composite femurs (n=8) with surface strains measured at four locations. The loading applied at the hip was the averaged peak joint reaction force during walking (Bergman et al); experimentally, this loading vector was used for a reduced load of 500N.Background
Methods
Understanding vertebral fracture is important in order to reduce fracture risk. Previous studies have used FE to investigate mechanical behaviour, typically using a linear material response. This study aimed to establish a novel model that could represent the plastic behaviour leading to fracture. Porcine vertebrae were mCT scanned and they were loaded to failure in a material test machine (Instron 5965). The specimens were then rescanned. From the first scan, specimen specific FE models were created (ScanIP, Simpleware, UK). Mesh convergence was studied and tetrahedral elements with an approximate element size of 0.7 were used for computational simulations. The relationship between greyscale values (GS) and Young's modulus (E) was optimised to match the experimental load displacement data using Ansys. Further, a plastic material response was modelled.Background
Method
Femoral head collapse is a possible complication after surgical treatment of femoral neck fractures. The purpose of this study was to examine whether implantation of a Sliding Hip Screw (SHS) or an X-Bolt could increase the risk of femoral head collapse. Similar to traditional hip screws, the X-Bolt is implanted through the femoral neck; however, it uses an expanding cross-shape to improve rotational stability. The risk of collapse was investigated alongside patient factors, such as osteonecrosis. This numerical study assessed the risk of femoral head collapse using linear eigenvalue buckling (an established method [1]), and also from the maximum von Mises stress within the cortical bone. The femoral head was loaded using the pressures reported by Yoshida
Osteonecrosis, modelled as a cone of bone of varying angle, and varying modulus values Cortical thinning Reduced cortical modulus Femoral head size Twenty-two finite element models were run for each implant condition (intact; implanted with the X-Bolt; implanted with a SHS), resulting in a total of 66 models. The finite element models were validated using experimental tests performed on five 4th generation composite Sawbones femurs (Malmö, Sweden), and verified against previously published results [1]. No significant difference was found between the X-Bolt and the SHS, for either critical buckling pressure ( The study by Volokh
Using Python scripting it is possible to automate the pre-processing, solving and post-processing stages of finite element analysis using ABAQUS software. This is particularly useful when running multiple models parametrically. When the model involves a bony part, it is necessary to assign material properties based on the CT scan to represent bone heterogeneity, and unfortunately this cannot currently be done from within ABAQUS using software such as Bonemat [1]. To address this issue a Python package was written called ‘py_bonemat_abaqus’ to assign material properties from within ABAQUS. The purpose of this study was to compare the material assignments of py_bonemat_abaqus and Bonemat, to compare the processing speed, and to describe the workflow. The software packages were compared using a CT scan of a half pelvis downloaded from the VAKHUM database, and the associated hexahedral finite element mesh of the left half pelvis. To examine different element types, the hexahedral mesh was converted to linear and quadratic tetrahedral elements by dividing each hexahedron into 5 tetrahedral elements. The equations used to convert the Hounsfield Unit ( Equation 1: Equation 2 The time taken to analyse the models by each software was assessed using a Windows 7 PC with a 64-bit operating system, 4 CPUS, 8 GB of RAM and an Intel Core I5-3470 processor. The mean difference between the moduulus assignment made by py_bonemat_abaqus and Bonemat was −0.05 kPa (range −10.19 to 4.50 kPa, standard deviation 0.62 kPa). The Python package took a similar time to run for all element types; this was between 109 and 126 s. Bonemat software was significantly faster, and took between 5 and 20 s. Finally, the Python package was successfully used from within a Python script to perform material assignment from within ABAQUS software in a fully automated manner. Material assignments were almost equivalent between the two software packages, with any differences explainable by rounding effects. To put the differences into context, a difference of −0.05 kPa is 0.00000002% of the typical modulus of cortical bone (20.7 GPa), and 0.00000003% of the modulus of trabecular bone (14.8 GPa) [3]. The Python package was slower to process the models, but was successfully able to assign material properties from within ABAQUS software as part of an automated script.
Knee arthroplasty is an effective intervention for painful arthritis when conservative measures have failed. Despite recent advances in component design and implantation techniques, a significant proportion of patients experience problems relating to the patella-femoral joint (PFJ). Detailed knowledge of the shape and orientation of the normal and replaced femoral trochlea groove is critical when considering potential causes of anterior knee pain. Furthermore, to date it has proved difficult to establish a diagnosis due to shortcomings in current imaging techniques for obtaining satisfactory coronal plane motion data of the patella in the replaced knee. The aim of this study was to correlate the trochlea shape of normal and replaced knees with corresponding coronal plane PFJ kinematic data. Bony and cartilagenous trochlea geometries from 3T MRI scans of 20 normal healthy volunteers were compared with both anatomical and standard total knee replacements (TKR) and patellofemoral joint replacement (PFJR) geometries. Following segmentation and standardized alignment, the path of the apex of the trochlea groove was measured using customized Matlab software. (Fig1). Next, kinematic data of the 20 normal healthy volunteers (Normal) was compared with that of 20 TKR, and 20 PFJR patients using the validated MAUSTM system Introduction
Method
The mechanical properties of porcine tibial plateau (TP) cartilage are shown to vary topographically. Low Elastic moduli (Em) were found in the positions where unicompartimental knee osteoarthritis (OA) lesions are typically expected to develop. These results suggest that there is a different response to load in these areas. OA is one of the ten most disabling diseases in developed countries. OA of the knee, in particular, is a major cause of mobility impairment; up to 40% of the population over the age of 70 suffers from OA of the knee. It has been observed that unicompartmental knee OA occurs with very distinct and repeatable lesion patterns. It is hypothesised that these patterns are the result of differences in the material properties throughout articular cartilage. The aim of this study was to measure the mechanical properties of porcine cartilage in a whole undamaged TP.Summary
Introduction
The required torque leading to an abrasion of the passive layer in the stem-head interface positively correlates to the assembly force. In order to limit the risk of fretting and corrosion a strong hammer blow seems to be necessary. Modular hip prostheses are commonly used in orthopaedic surgery and offer a taper connection between stem and ball head. Taper connections are exposed to high bending loads and bear the risk of fretting and corrosion, as observed in clinical applications. This is particularly a problem for large diameter metal bearings as the negative effects may be enhanced due to the higher moments within the taper connection. Currently, it is not known how much torque is required to initiate a removal of the passive layer, which might lead to corrosion over a longer period and limits the lifetime of prostheses. Therefore, the purpose of this study was to identify the amount of torque required to start an abrasion of the passive layer within the interface dependent on the assembly force and the axial load.Summary
Introduction
Simulated increases in body weight led to increased displacement, von Mises stress, and contact pressure in finite element models of the extended and flexed knee. Contact shifted to locations of typical medial osteoarthritis lesions in the extended knee models. Obesity is commonly associated with increased risk of osteoarthritis (OA). The effects of increases in body weight and other loads on the stresses and strains within a joint can be calculated using finite element (FE) models. The specific effects for different individuals can be calculated using subject-specific FE models which take individual geometry and forces into account. Model results can then be used to propose mechanisms by which damage within the joint may initiate.Summary Statement
Introduction
Previous attempts to measure coronal plane patellofemoral kinematics following knee replacement have suffered from methodological drawbacks; the patella being obscured by the components, metal artefact and technical inaccuracies. The aim of this study was to assess whether there was any significant difference in the patellofemoral kinematics between normal, TKR and PFJR patients using the validated MAUS™ technique (combining motion analysis with ultrasound). 60 patients were recruited into three groups; normal healthy volunteers (Normal), TKR, and PFJR patients. The MAUS technique incorporates a 12 camera analysis system (providing gross alignment data for tibial and femoral segments) and an ultrasound probe (providing coordinates of bony landmarks on patella femur and tibia) during a squat exercise. 6 DOF kinematics were described between 0 and 90° flexion. The validated accuracy of the MAUS technique registering the ultrasound images within the motion capture system is 1.84 mm (2 × SD). Movements of the Normal group were significantly different from the TKR group (p=0.03) and the PFJR group (p<0.01), whilst there was no significant difference between the TKR and PFJR groups (p=0.27). Our data suggest that many aspects of patellofemoral kinematics are absent following TKR and PFJR, which could be addressed in future designs of knee TKR and PFJR.
Unicompartmental Knee Replacement (UKR) is associated with fewer complications, faster recovery and better function than Total Knee Replacement (TKR). However, joint registries demonstrate a higher revision rate in UKR, limiting its use. Currently most UKRs are cemented and performed using a minimally invasive technique. In joint registries, common reasons for revision include aseptic loosening and pain. These problems could potentially be addressed by using cementless implants, which may provide more reliable fixation. The objectives of this study were to compare the quality of fixation (determined by the incidence and appearance of radiolucencies), and clinical outcomes of cemented and cementless UKR at five years. A randomised controlled trial was established with 63 knees (62 patients) randomised to either cemented (32 patients) or cementless UKR (30 patients). Fixation was assessed with fluoroscopic radiographs aligned to the bone-implant interface at one and five years. Outcome scores were collected pre-operatively and at one, two and five years, including Oxford Knee Score (OKS), American Knee Society Score, objective and functional (AKSS-O/F) and Tegner Activity Scale (TAS), expressed as absolute scores and 0–5 year change (δ) scores. Four patients died during the study period. There were no revisions. Mean operative time was 11 minutes shorter in the cementless group (p=0.029). At five years, there was no significant difference in any outcome measure except AKSS-F and δAKSS-F which were significantly better in the cementless group (both p=0.003). There were no femoral radiolucencies in either group. There were significantly more tibial radiolucencies in the cemented group (20/30 vs 2/27, p< 0.001). There were nine complete radiolucencies in the cemented group and none in the cementless group (p< 0.001). Cementless fixation provides improved fixation at five years compared to cemented fixation in UKR, maintaining equivalent or superior clinical outcomes with a shorter operative time and no increase in complications.
Subtle deformities of the acetabulum and proximal femur are recognised as biomechanical risk factors for the development of hip osteoarthritis (OA) as well as a cause of hip and groin pain. We undertook this study to examine relationships between a number of morphological measurements of the acetabulum and proximal femur and the hip pain in a 20-year longitudinal study. In 1989 women of 45–64 years of age were recruited. Each had an AP-Pelvis radiograph at Year-2. These radiographs were analysed using a validated programme for measuring morphology. All morphological measurements were read blinded to outcome. At year 3 all participants were asked whether they experienced hip pain (side specific). This was repeated at visits up to and including 20-years. Logistic regression analysis (with robust standard errors and clustering by subject identifier) was performed using hip pain as a binary outcome. The model adjusted for baseline age, BMI and joint space and included only participants who were pain free on initial questioning.Introduction
Methods
Indications for Unicompartmental Knee Arthroplasty (UKA) vary between units. Some authors have suggested, and many surgeons believe, that medial UKA should only be performed in patients who localise their pain to the medial joint line. This is despite research showing a poor correlation between patient-reported location of pain and radiological or operative findings in osteoarthritis. The aim of this study is to determine the effect of patient-reported pre-operative pain location and functional outcome of UKA at one and five years. Pre-operative pain location data were collected for 406 knees (380 patients) undergoing Oxford medial UKA. Oxford Knee Score, American Knee Society Scores and Tegner activity scale were recorded preoperatively and at follow-up. 272/406 (67%) had pure medial pain, 25/406 (6%) had pure anterior knee pain and 109/406 (27%) had mixed or generalised pain. None had pure lateral pain. The primary outcome interval is one year; 132/406 patients had attained five years by the time of analysis and their five year data is presented. At one and five years, each group had improved significantly by each measure (mean δOKS 15.6 (SD 8.9) at year one, 16.3 (9.3) at year five). There was no difference between the groups, nor between patients with and without anterior knee pain or isolated medial pain. We have found no correlation between preoperative pain location and outcome. We conclude that localised medial pain should not be a prerequisite to UKA and that it may be performed in patients with generalised or anterior knee pain.
Solid or cystic pseudotumour is a potentially destructive complication of metal on metal (MoM) couples, usually needing revision surgery. However, complete clearance of the pseudotumour is unlikely at times. This prospective case-controlled study reports cases which had recurrence after revision surgery for pseudotumour related to metal on metal hip couples. A total of 37 hips (33 MoM hip resurfacing and four big head MoM total hip arthroplasty (THA)) were revised for pseudotumour during the last 10 years. The patient demographics, time to revision, cup orientation, operative and histological findings were recorded for this cohort. Patients were divided into two groups - group R (needing re-revision for disease progression) and group C (control - no evidence of disease progression). Oxford hip scores (OHS, 0–48, 48 best outcome) were used to assess clinical outcome. The diagnosis of disease progression was based on recurrence of clinical symptoms, cross-sectional imaging, operative and histological findings.Introduction
Methods
Motion analysis is a validated method of assessing technical dexterity within surgical skills centers. A more accessible and cost-effective method of skills assessment is to use a global rating scale (GRS). We aimed to perform a validation experiment to compare an arthroscopic GRS against motion analysis for monitoring orthopaedic trainees learning simulated arthroscopic meniscal repairs. An arthroscopic meniscal repair task on a knee simulator was set up in a bioskills laboratory. Nineteen orthopaedic trainees with no experience of meniscal repair were recruited and their performance assessed whilst undertaking a standardized meniscal repair on 12 occasions. An arthroscopic GRS, assessing parameters such as “depth perception,” “bimanual dexterity,” “instrument handling,” and “final product analysis” was used to evaluate technical skill. Performance was assessed blindly by watching video recordings of the arthroscopic tasks. Dexterity analysis was performed using a motion analysis tracking system which measured “time taken,” “total path length of the subject's hands,” and “number of hand movements”.Introduction
Methods
Stem geometry is known to influence the outcome in THA; however it is unknown whether the material properties, stiffness in particular can influence the stem stability and outcome. The aim of this study was to measure the influence of stem material properties on micromotion and migration using Roentgen Stereophotogrammetric Analysis (RSA) system. 41 patients were implanted with a collarless polished tapered (CPT) femoral stem (Zimmer, Warsaw, Indiana), which was made of either cobalt-chromium (CoCr) (n=21) or stainless steel (n=20). RSA was used to measure dynamically inducible micromotion (DIMM: difference in stem position in going from double-leg stance (DLS) to single leg stance (SLS)), prosthesis bending (difference in the head-tip distance when going from DLS to SLS), and mean migration of the head, tip and the cement restrictor. DIMM and bending were measured at 3 months, migration at 6, 12 and 24 months. All analyses were carried out using SPSS for windows (v.15.0.0, Chicago. IL, USA). Results were reported as mean ± 95% confidence interval (CI) and regarded as significant when p < 0.05.Introduction
Methods
Since the introduction of 3rd generation Metal-on-Metal-Hip-Resurfacing-Arthroplasty (MoMHRA), thousands of such prostheses have been implanted worldwide in younger patients with end-stage hip osteoarthritis. However, no independent centre has reported their medium-to-long term outcome. The aim of this study is to report the ten year survival and outcome of the Birmingham Hip Resurfacing (BHR), the most commonly used MoMHRA worldwide. Since 1999, 648 BHRs were implanted in 555 patients, the majority of which were male (326). The mean age at surgery was 52.1years (range: 17–82), with primary OA as most common indication (85%). Mean follow up was 7.1years (range: 1–11). The Oxford Hip Score (OHS) and UCLA questionnaires were sent to all patients. Implant survival was established, with revision as the end point. Sub-analysis was performed by gender, femoral component size (small: <45mm, standard: 46–52, large: >53mm) and age at surgery (young:<50yrs, old:>50yrs).Introduction
Methods
Metal-on-metal hip resurfacing arthroplasty (MoMHRA) is a surgical option in the treatment of end-stage hip disease. The measurement of systemic levels of metal ions gives an insight into the wear occurring and is advocated by regulatory bodies as routine practice in the assessment of resurfaced hips. However, the acceptable upper levels of Chromium (Cr) and Cobalt (Co) ions concentration with clinical significance still have to be established. The aim of this study is to address this issue in unilateral and bilateral resurfaced hips. 453 patients with unilateral MoMHRA and 139 patients with bilateral MoMHRA at >12 months postoperative were retrospectively identified from an independent hip specialist's database. Routine metal ion levels were measured at last follow-up (ICPMS protocol). Radiological assessment included measurement of acetabular component orientation using EBRA, calculation of contact patch to rim (CPR) distance, and evaluation for any adverse X-ray findings. The cohort was divided into the well functioning group (Group A) and the non-well functioning group (Group B). A well functioning resurfacing gad to fulfil all of the following criteria (bilateral patients had to fulfil criteria for both hips): no patient reported hip complaints, no surgeon detected clinical findings, HHS> 95, CPR distance> 10mm, no abnormal radiological findings and no further operation scheduled. Upper levels (acceptable limits) of Cr/Co were considered to be represented by the top margin of the box-whisker plot [upper limit = 75th quartile value + (1.5 x interquartile range)] in Group A.INTRODUCTION
METHODS
Interest in soft tissue Radiostereometric Analysis (RSA) is rising. Previous authors have tried, with varying levels of success, to use this technique to analyse the intra-substance portion of anterior cruciate ligament (ACL) graft constructs. These methods were either prone to large amounts of marker migration, deemed unsuitable for in-vivo use or, where alternative markers such as stainless steel sutures were used, lost the inherent accuracy that made RSA an attractive tool in the first place. We describe a modification of tantalum marker balls that allows for a new method of secure fixation to soft tissue in order to accurately analyse stretch, displacement and, potentially, dynamic movement using RSA. 1.5 mm tantalum tendon markers were predrilled with 0.3 mm holes, allowing them to be sutured directly to soft tissue. Using a previously described ACL graft model, the amount of marker ball migration was then analysed using RSA after cyclical loading between 20 N and 170 N at 25 Hz for 225,000 cycles.Aims
Methods
Femoral neck narrowing (NN) following Metal-on-Metal Hip Resurfacing Arthroplasty (MoMHRA) is a well-recognised clinical phenomenon. The incidence of resurfaced hips with NN > 10% is reported to be up to 27%. Its pathogenesis is thought to be multi-factorial secondary to stress shielding, impingement, osteolysis secondary to wear/ion particles and as a result of reduced vascularity and pressure effect on cancellous bone secondary to the presence of a soft-tissue mass around the resurfaced hip. Recognised risk factors for its development include: female gender and the presence of a pseudotumour. Serum Chromium (Cr) and Cobalt (Co) are recognised surrogate markers of in-vivo wear of MoMHRA. The aims of this study were to establish whether NN is associated with increased wear. A cohort of 214 patients with unilateral MoMHRA (139M: 75F) was included in this study. Primary osteoarthritis was the diagnosis leading to surgery for the majority of patients (208). The average age at surgery was 54.1 years old (13–73). Six different implants were used; BHR (116), Conserve plus (92), Recap (2), ASR (2), Adept (1) and Cormet (1). The average femoral component size was 49.2mm (range: 38–59). The average follow up was 4.3 years (range: 2–10). Patients were subdivided into 3 groups as per implant size. Small size component group had implants <45mm, average size group had components 45–51mm and large component size group had components >51mm. All patients had Prosthesis-Junction-Ratio (PJR) measured from postoperative (PJRpost) and at latest follow up (PJRfollow) radiographs. Measurements were made using the method described by Lilikakis1. Metal ion levels (Cr/Co) were measured at last follow-up for all patients. Cr level >5.1g/ml and Co levels >4.4 g/ml were considered high2 and patients with such levels formed the high ion group.INTRODUCTION
METHODS
Osteoarthritis (OA) of the hip is an important cause of pain and morbidity. The mechanisms and pathogenesis of OA'sdevelopment remain unknown. Minor acetabular dysplasia and subtle variations in proximal femoral morphology are increasingly being recognized as factors that potentially compromise the joint biomechanically and lead to OA. Previous studies have shown that risk of hip OA increased as the femoral head to femoral neck ratio (HNR) decreased. Previous work has described the evolutionary change in inferior femoral neck trabecular density and geometry associated with upright stance, but no study has highlighted the evolutionary change in HNR. The aim of this study was to examine evolutionary evidence that the hominin bipedal stance has lead to alterations in HNR that would predispose humans to hip OA. A collaboration with The Natural History Museums of London, Oxford and the Department of Zoology, University of Oxford provided specimens from the Devonian, Jurassic, Cretaceous, Miocene, Palaeolithic and Pleistocene periods to modern day. Specimens included amphibious reptiles, dinosaurs, shrews, tupaiae, lemurs, African ground apes, Lucy (A. Afarensis), H. Erectus, H. Neaderthalis and humans. Species were grouped according to gait pattern; HAKF (hip and knee flexed), Arboreal (ability to stand with hip and knee joints extended) and hominin/bi-pedal. Imaging of specimens was performed using a 64 slice CT scanner. Three-dimensional skeletal geometries were segmented using MIMICS software. Anatomical measurements from bony landmarks were performed to describe changes in HNR, in the coronal plane of the different specimens over time using custom software. Measurements of HNR from the specimens were compared with HNR measurements made from AP pelvic radiographs of 119 normal subjects and 210 patients with known hip OA listed for hip arthroplasty.Introduction
Methods
Malalignment of some designs of stem is associated with an increased risk of aseptic loosening and revision. We investigated whether the alignment of the cemented polished, double-taper design adversely affected outcome, in a multicentre prospective study. A multicentre prospective study of 1189 total hip replacements was undertaken to investigate whether there is an association between surgical outcome and femoral stem alignment. All patients underwent a primary THR with the Exeter femoral stem (Stryker Howmedica Osteonics, Mahwah, NJ) and a variety of acetabular components. The primary outcome measure was the Oxford hip score (OHS) and change in OHS at five years. Secondary outcomes included rate of dislocation and revision. Radiographic evaluation of the femoral component was also undertaken. The long axis of the Exeter femoral component and the long axis of the femoral canal were located, and the angle at the point of intersection measured. The cementing quality was determined as defined by Barrack et al. Radiolucent lines at the cement-stem and cement-bone interface in the five year radiographs were defined using the zones described by Gruen et al. Subsidence was measured as the vertical dimension of the radiolucency craniolateral to the shoulder of the stem in Gruen zone 1 as described by Fowler et al. Cement fractures were recorded.Introduction
Methods
The options for the treatment of the young active patient with unicompartmental symptomatic osteoarthritis and pre-existing Anterior Cruciate Ligament (ACL) deficiency are limited. Patients with ACL deficiency and end-stage medial compartment osteoarthritis are usually young and active. The Oxford Unicompartmental Knee Replacement (UKA) is a well established treatment option in the management of symptomatic end-stage medial compartmental osteoarthritis, but a functionally intact ACL is a pre-requisite for its satisfactory outcome. If absent, high failure rates have been reported, primarily due to tibial loosening. Previously, we have reported results on a consecutive series of 15 such patients in whom the ACL was reconstructed and patients underwent a staged or simultaneous UKA. The aim of the current study is to provide an update on the clinical and radiological outcomes of a large, consecutive cohort of patients with ACL reconstruction and UKA for the treatment of end-stage medial compartment osteoarthritis and to evaluate, particularly, the outcome of those patients under 50. This study presents a consecutive series of 52 patients with ACL reconstruction and Oxford UKA performed over the past 10 years (mean follow-up 3.4 years). The mean age was 51 years (range: 36–67). Procedures were either carried out as Simultaneous (n=34) or Staged (n=18). Changes in clinical outcomes were measured using the Oxford Knee Score (OKS), the change in OKS (OKS=Post-op − Pre-op) and the American Knee Society Score (AKSS). Fluoroscopy assisted radiographs were taken at each review to assess for evidence of loosening, radiolucency progression, (if present), and component subsidence.Introduction
Methods
Studies have suggested that there is a reduction in head-neck-ratio (HNR) associated with MoMHRA. A reduction in HNR at operation would decrease range of movement and increase impingement risk. Impingement could lead to 20 edge loading, increasing wear. Serum ion levels of Chromium (Cr) and Cobalt (Co) are surrogate markers of wear. Although acetabular component orientation has been shown to contribute to wear and PT development, the role of a decrease in HNR has only been highlighted in PT development. This study aimed to measure changes in HNR that occur at resurfacing and determine any gender- and component size-specific differences. In addition it aimed to determine whether changes in HNR could be associated with increased wear. 84 patients (56M: 28F) with unilateral MoMHRA were included. The mean age at surgery was 57 years. The mean femoral component was 49mm. Components were considered small if <45mm, average if between 45–50mm and large if >50mm. Three designs were implanted; BHR, C+ and Recap. The average follow up was 4 years. All patients had Cr/Co levels measured at follow up. Patients were considered to have high ions if Cr and Co levels were 5.1ppb and 4.4ppb respectively. Pre-operative HNR (HNRpre) and the post-operative HNR (HNRpost) were made from the respective pelvic radiographs. Assuming a 2mm thick cartilage layer, the HNR based on the diameter of the articular cartilage pre-operatively (HNRart) was calculated. The immediate changes in HNR as a result of the operation were expressed relative to articular HNR pre-op: HNRartpost=HNRpost–HNRartINTRODUCTION
METHODS
Radiolucencies beneath the tibial component are well recognized in knee arthroplasty; the aetiology and significance are poorly understood. Non-progressive narrow radiolucencies with a sclerotic margin are thought not to be indicative of loosening. Factors which decrease the incidence of radiolucencies include cementless fixation and the use of pulse lavage. Leg/component alignment or BMI do not influence radiolucency. We are not aware of any studies that have looked at the effect of load type on radiolucency. The Oxford domed lateral tibial component was introduced to decrease the bearing dislocation rate that was unacceptably high with the flat tibial tray. However, the introduction of the domed tibial component alters the forces transmitted through the implant-cement-bone interface. As the Oxford UKR uses a fully congruent mobile bearing, the forces transmitted through the interface with a flat tray are compressive, except for the effect of friction. However, with the domed tibial component shear forces are introduced. The aim of this study was to assess the prevalence of radiolucency beneath the previous flat design and the new domed tibial tray. A consecutive series of 248 cemented lateral UKRs (1999–2009) at a single institution were assessed. The first 55 were with a flat tibia and the subsequent 193 with a domed component. One year post-op radiographs were assessed, by two observers, for the presence (full or partial) and distribution of radiolucency. The distribution and thickness of each radiolucency. Cases were excluded for missing or poorly aligned radiographs.Introduction
Patients and methods
Although simulation studies have shown superior wear properties of metal-on-metal articulations, increased concern exists regarding the excess in-vivo wear of a small number of Metal-on-Metal-Hip-Resurfacing (MoMHRA) implants. Serum ion levels of Chromium (Cr) and Cobalt (Co) are surrogate markers of wear. Risk factors associated with increased wear include female gender, small components, dysplasia, cup orientation outside safe zone and femoral head downsize during surgery with an associated decrease in Head-Neck-Ratio (HNR). However, these factors are interlinked. This study aims to identify the factors that are most important for subsequent wear of MoMHRA, by performing a multivariate analysis. 206 patients (124M: 82F) with unilateral MoMHRA were included in this study. The average follow up was 3.3 years. All patients had Cr/Co levels measured at follow up. Inclination and anteversion of each cup were measured using EBRA. Cups were analysed as being within or outside the previously defined optimum-zone. HNR measurements were made from pre-operative (HNRpre) and post-operative (HNRpost) radiographs. The immediate changes in HNR (downsize/upsize of femoral head) as a result of the operation were expressed as: HNRprepost=HNRpost–HNRpre Multivariate linear regression modelling was used to explore the association between measures of ions with the following predictor variables (gender, age, diagnosis, femoral component size, orientation of the acetabular component, head/neck ratio and position of femoral stem). Analyses were carried out separately for each outcome (Cr and Co). Classification and Regression Tree (CART) models were fitted as a complimentary approach to regression modelling.INTRODUCTION
METHODS
The introduction of hard-on-hard bearings and the consequences of increased wear due to edge-loading have renewed interest in the importance of acetabular component orientation for implant survival and functional outcome following hip arthroplasty. Some studies have shown increased dislocation risk when the cup is mal-oriented which has led to the identification of a safe-zone1. The aims of this prospective, multi-centered study of primary total hip arthroplasty (THA) were to: 1. Identify factors that influence cup orientation and 2. Describe the effect of cup orientation on clinical outcome. In a prospective study involving seven UK centers, patients undergoing primary THA between January 1999 and January 2002 were recruited. All patients underwent detailed assessment pre-operatively as well as post-op. Assessment included data on patient demographics, clinical outcome, complications and further surgery/revision. 681 primary THAs had adequate radiographs for inclusion. 590 hips received cemented cups. The primary functional outcome measure of the study was the change between pre-operative and at latest follow up OHS (OHS). Secondary outcome measures included dislocation rate and revision surgery. EBRA was used to determine acetabular inclination and version. The influence of patient's gender, BMI, surgeon's grade and approach on cup orientation was examined. Four different zones tested as possibly ± (Lewinnek Zone, Callanan's described zone and zones ± 5 and ±10 about the study's mean inclination and anteversion) for a reduced dislocation risk and an optimal functional outcome.INTRODUCTION
METHODS
Technical skill is an essential domain of surgical competency. Arthroscopic surgery forms a particularly challenging subset of these skills. The innate ability to acquire these skills is not fully understood. The aim of this study was to investigate the innate arthroscopic skills and learning curve patterns of medical students - our future surgeons. Two arthroscopic tasks (one shoulder and one knee) were set up in a bioskills laboratory to represent core skills required for arthroscopic training. Twenty medical students with no previous arthroscopic surgery experience were recruited and their performance assessed whilst undertaking each task on 30 occasions. The primary outcome variable was success or failure. Individuals were assessed as ‘competent’ if they stabilised their learning curve within 20 episodes. The secondary outcome measure was an objective assessment of technical dexterity using a validated Motion Analysis system (time taken to complete tasks, total path length of the subject's hands, and number of hand movements).Background
Methods
The ability to learn arthroscopic surgery is an important aspect of modern day orthopaedic surgery. Knowing that variation in innate ability exists amongst medical students, the aim of this study was to investigate the effect of training on the arthroscopic surgical performance of our future orthopaedic surgeons (medical students). Two arthroscopic tasks (one shoulder and one knee) were set up in a bioskills laboratory to represent core skills required for arthroscopic training. Thirty three medical students with no previous arthroscopic surgery experience were randomised to a ‘Trained’ (n=16) and ‘Non-trained’ (n=17) cohort. Both groups watched an instructional video. The Trained cohort also received specific training on the tasks prior to their first episode. Thirty episodes of each task were then undertaken. The primary outcome variable was success or failure. Individuals were assessed as ‘competent’ if they stabilised their learning curve within 20 episodes. The secondary outcome measure was an objective assessment of technical dexterity using a validated Motion Analysis system (time taken to complete tasks, total path length of the subject's hands, and number of hand movements).Background
Methods
In pre-operative planning for total hip arthroplasty (THA), femoral offset (FO) is frequently underestimated on AP pelvis radiographs as a result of inaccurate patient positioning, imprecise magnification, and radiographic beam divergence. The aim of the present study was to evaluate the reliability and accuracy of predicting three-dimensional (3-D) FO as measured on computed tomography (CT) from measurements performed on standardised AP pelvis radiographs. In a retrospective cohort study, pre-operative AP pelvis radiographs and corresponding CT scans of a consecutive series of 345 patients (345 hips, 146 males, 199 females, mean age 60 (range: 40-79) years, mean body-mass-index 27 (range: 29-57) kg/m2) with primary end-stage hip osteoarthritis were reviewed. Patients were positioned according to a standardised protocol and all images were calibrated. Using validated custom programmes, FO was measured on corresponding AP pelvis radiographs and CT scans. Inter- and intra-observer reliability of the measurement methods were evaluated using intra-class correlation coefficients (ICC). To predict 3-D FO from AP pelvis measurements, the entire cohort was randomly split in two groups and gender specific linear regression equations were derived from a subgroup of 250 patients (group A). The accuracy of the derived prediction equations was subsequently assessed in a second subgroup of 100 patients (group B). In the entire cohort, mean FO was 39.2mm (95%CI: 38.5-40.0mm) on AP pelvis radiographs and 44.6mm (95%CI: 44.0-45.2mm) on CT scans. FO was underestimated by 14% on AP pelvis radiographs compared to CT (5.4mm, 95%CI: 4.8-6.0mm, p<0.001) and both parameters demonstrated a linear correlation (r=0.642, p<0.001). In group B, we observed no significant difference between gender specific predicted FO (males: 48.0mm, 95%CI: 47.1-48.8mm; females: 42.0mm, 95%CI: 41.1-42.8mm) and FO as measured on CT (males: 47.7mm, 95%CI: 46.1-49.4mm, p=0.689; females: 41.6mm, 95%CI: 40.3-43.0mm, p=0.607). The results of the present study suggest that femoral offset can be accurately and reliably predicted from AP pelvis radiographs in patients with primary end-stage hip osteoarthritis. Our findings support the surgeon in pre-operative templating and may improve offset and limb length restoration in THA without the routine performance of CT.
In uncemented total hip arthroplasty (THA), the optimal femoral component should allow both maximum cortical contact with proximal load transfer and accurate restoration of individual joint biomechanics. This is often compromised due to a high variability in proximal femoral anatomy. The aim of this on-going study is to assess the variation in proximal femoral canal shape and its association with geometric and anthropometric parameters in primary hip OA. In a retrospective cohort study, AP-pelvis radiographs of 98 consecutive patients (42 males, 56 females, mean age 61 (range:45-74) years, BMI 27.4 (range:20.3-44.6) kg/m2) who underwent THA for primary hip OA were reviewed. All radiographs were calibrated and femoral offset (FO) and neck-shaft-angle (NSA) were measured using a validated custom programme. Point-based active shape modelling (ASM) was performed to assess the shape of the inner cortex of the proximal femoral meta- and diaphysis. Independent shape modes were identified using principal component analysis (PCA). Hierarchical cluster analysis of the shape modes was performed to identify natural groupings of patients. Differences in geometric measures of the proximal femur (FO, NSA) and demographic parameters (age, height, weight, BMI) between the clusters were evaluated using Kruskal-Wallis one-way-ANOVA or Chi-square tests, as appropriate. In the entire cohort, mean FO was 39.0 mm, mean NSA was 131 degrees. PCA identified 10 independent shape modes accounting for over 90% of variation in proximal femoral canal shape within the dataset. Cluster Analysis revealed 6 shape clusters for which all 10 shape modes demonstrated a significantly different distribution (p-range:0.000-0.015). We observed significant differences in age (p=0.032), FO (p<0.001) and NSA (p<0.001) between the clusters. No significant differences with regard to gender or BMI were seen. Our preliminary analysis has identified 6 different patterns of proximal femoral canal shape which are associated with significant differences in femoral offset, neck-shaft-angle and age at time of surgery. We are currently evaluating the entire dataset of 345 patients which will allow a comprehensive classification of variation in proximal femoral shape and joint geometry. The present data may optimise preoperative planning and improve future implant design in THA.
Traditional TKR designs exhibit abnormal and unpredictable kinematics: with posterior subluxation in extension and anterior slide with flexion. These can contribute to restricted knee flexion and reduced quadriceps efficiency. Newer designs attempt to provide “guided motion” with the aim of mimicking normal knee kinematics. The Journey (Smith & Nephew) BCS TKR incorporates both an anterior and a posterior cam/post mechanism while Triathlon PS TKR (Stryker) incorporates a posterior cam/post mechanism. This study compares the in-vivo kinematics of these two designs and compares it with normal knee. Knee kinematics of 10 patients with Journey-BCS TKR and 11 patients with Triathlon PS TKR; all with excellent clinical outcome (average age: 65) were analysed. Patients underwent fluoroscopic assessment of the knee during a step-up and deep knee bend exercise. 2D fluoroscopic images were recorded. Data was analysed for patella tendon angle (PTA) and contact points using a 3D model fitting technique. This data was compared to normal knee kinematics (n=20).Introduction
Methods
A femoral head/neck ratio (HNR) of less than 1.27 is associated with an increased risk of arthritis. The aim of this study was to establish whether there is evolutionary evidence that the homonin, bipedal stance has led to alterations in HNR that predispose humans to osteoarthritis (OA). Specimens provided by The Natural History Museums of London, Oxford and the Department of Zoology, University of Oxford were grouped according to gait pattern, HAKF (Hip and knee flexed), Arboreal (ability to stand with hip and knee joints extended) and homonin/bi-pedal. Specimens included those from Devonion, Triassic, Jurrasic, Cretaceous, Miocene, Paleolithic, Pleistocene periods to modern day. Three-dimensional skeletal geometries were segmented using CT images and HNR measurements were taken from coronal views. These were compared with the HNR of 119 asymptomatic human volunteers and 210 patients that had a hip joint replacement for primary OA. Species of the HAKF group had the smallest HNR (1.10, SD:0.09). Species of the Arboreal group had significantly higher HNR (1.63, SD:0.15) in comparison to the Bipedal group (1.41, SD:0.04) (p=0.006), Human (1.33, SD:0.08) and the OA group (1.3, SD:0.09). The range of movement associated with arboreal habitat caused an associated change in HNR. This study would suggest that the HNR peaked in the Miocene period with species that ambulated on both ground and trees. More recent homonin gait appears to have developed a smaller HNR and humans have the smallest amongst their close ancestors. Evolutionary theory would suggest that modern environmental pressures might pre-dispose future hominin evolution to OA, secondary to a further reduction in HNR.
Stem geometry is known to influence the outcome in THA; however it is unknown whether the material properties, stiffness in particular can influence the stem stability and outcome. The aim of this study was to measure the influence of stem material properties on micromotion and migration using Roentgen Stereophotogrammetric Analysis (RSA) system. 41 patients were implanted with a collarless polished tapered (CPT) femoral stem (Zimmer, Warsaw, Indiana), which was made of either cobalt-chromium (CoCr) (n=21) or stainless steel (n=20). RSA was used to measure dynamically inducible micromotion (DIMM: difference in stem position in going from double-leg stance (DLS) to single leg stance (SLS)), prosthesis bending (difference in the head-tip distance when going from DLS to SLS), and mean migration of the head, tip and the cement restrictor. DIMM and bending were measured at 3 months, migration at 6, 12 and 24 months. All analyses were carried out using SPSS for windows (v.15.0.0, Chicago. IL, USA). Results were reported as mean ± 95% confidence interval (CI) and regarded as significant when p < 0.05. Preliminary analysis showed that total head DIMM was significantly (p = 0.02) greater for CoCr (0.97mm ± 0.6mm) than stainless steel (0.27mm ± 0.6mm). The mean stem bending for CoCr was 0.08mm (± 0.06mm) and for stainless steel 0.15mm (± 0.06mm) (p =0.77). Both implants heads migrated posteriorly, medially and distally. The mean subsidence for the cobalt-chromium and stainless steel stems was 1.02mm (± 0.19mm) (p < 0.001) and 1.12mm (± 0.34mm) (p=0.001) (p= 0.07) at 24 months. It was interesting to note that the dynamically induced micromotion was greater for the stiffer stem, however there were no differences in terms of overall migration, indicating that survival (in terms of loosening) should be the similar for both steel and CoCr versions of this implant.
Primary mechanical stability is important with uncemented THR because early migration is reduced, leading to more rapid osseointegration between the implant and bone. Such primary mechanical stability is provided by the design features of the device. The aim of this study was to compare the migration patterns of two uncemented hip stems, the Furlong Active and the Furlong HAC stem; the study was designed as a randomised control trial. The implants were the Furlong HAC, which is an established implant with good long term results, and the Furlong Active, which is a modified version of the Furlong HAC designed to minimise stress concentrations between the implant and bone, and thus to improve fixation. The migration of 43 uncemented femoral components for total hip replacement was measured in a randomised control trial using Roentgen Stereophotogrammetric Analysis (RSA) over two years. Twenty-three Furlong HAC and twenty Furlong Active stems were implanted into 43 patients. RSA examinations were carried out post-operatively, and at six months, 12 months and 24 months post-operatively. The patients stood in-front of a purpose made calibration frame which contained accurately positioned radio-opaque markers. From the obtained images, the 3-D positions of the prosthesis and the host bone were reconstructed. Geometrical algorithms were used to identify the components of the implant. These algorithms allowed the femoral component to be studied without the need to attach markers to the prosthesis. The migration was calculated relative to the femoral coordinate system representing the anterior-posterior (A-P), medial-lateral (M-L) and proximal-distal (P-D) directions respectively. Distal migration was termed subsidence.Introduction
Materials and methods
Anteromedial osteoarthritis of the knee (anteromedial gonarthrosis-AMG) is a common form of knee arthritis. In a clinical setting, knee arthritis has always been assessed by plain radiography in conjunction with pain and function assessments. Whilst this is useful for surgical decision making in bone on bone arthritis, plain radiography gives no insight to the earlier stages of disease. In a recent study 82% of patients with painful arthritis had only partial thickness joint space loss on plain radiography. These patients are managed with various surgical treatments; injection, arthroscopy, osteotomy and arthroplasty with varying results. We believe these varying results are in part due to these patients being at different stages of disease, which will respond differently to different treatments. However radiography cannot delineate these stages. We describe the Magnetic Resonance Imaging (MRI) findings of this partial thickness AMG as a way of understanding these earlier stages of the disease. 46 subjects with symptomatic partial thickness AMG underwent MRI assessment with dedicated 3 Tesla sequences. All joint compartments were scored for both partial and full thickness cartilage lesions, osteophytes and bone marrow lesions (BML). Both menisci were assessed for extrusion and tear. Anterior cruciate ligament (ACL) integrity was also assessed. Osteophytes were graded on a four point scale in the intercondylar notch and the lateral margins of the joint compartments. Scoring was performed by a consultant radiologist and clinical research fellow using a validated MRI atlas with consensus reached for disagreements. The results were tabulated and relationships of the interval data assessed with linear by linear Chi2 test and Pearson's Correlation.Introduction
Method
The results of the original mobile bearing Oxford unicompartmental knee replacement (UKR) in the lateral compartment have been disappointing because of high dislocation rates (11%). This original implant used a flat bearing articulation on the tibial tray. To address the issue of dislocation a new implant (domed tibia with biconcave bearing to increase entrapment) was introduced with a modified surgical technique. The aim of this study was to compare the risk of dislocation between a domed and flat lateral UKR. Separate geometric computer models of an Oxford mobile bearing lateral UKR were generated for the two types of articulation between the tibial component and the meniscal bearing: Flat-on-flat (flat) and Concave-on-convex (domed). Each type of mobile bearing was used to investigate three distinct dislocation modes observed clinically: lateral to medial dislocation, with the bearing resting on the tray wall (L-M-Wall); medial to lateral dislocation, out of the joint space (M-L); anterior to posterior dislocation, out of the joint space (A-P). A size C tray and a medium femoral component and bearing were used in all models. The femoral component, tibial tray and bearing were first aligned in a neutral position. For each dislocation the tibial tray was restrained in all degrees of freedom. The femoral component was restrained from moving in the anterior-posterior directions and in the medial-lateral directions. The femoral component was also restrained from rotating about the anterior-posterior, medial-lateral and superior-inferior directions. This meant that the femoral component was only able to move in the superior-inferior direction. Different bearing sizes were inserted into the model and the effect that moving the femoral component medially and laterally had on the amount of distraction required to cause bearing dislocation was investigated.Introduction
Methods
Osteoarthritis (OA) is a degenerative, chronic disease of the articular cartilage that affects more than 150 million people [1]. In the knee, OA can begin as either isolated medial OA or isolated lateral OA. Previous research [2,3] shows medial OA and lateral OA have characteristic cartilage lesion locations and progression patterns as well as flexion angles associated with lesion development, indicating strong involvement of mechanical factors in disease initiation. Therefore, it is important to investigate these mechanical factors. Previous studies combined data sets (geometry, motion, load) from separate sources. The aim of the current work was to use a consistent multi-modal approach. A finite element (FE) model of a healthy knee in full extension was created using magnetic resonance imaging (MRI) and motion analysis data from the same subject (female, 24 yrs). MRI data was obtained using a 3T MRI scanner (Philips Medical Systems/Achieva). Surface geometries of the tibia, femur, and associated cartilage were then semi-automatically segmented and processed (Mimics 12.5; Geomagic Studio 11; SolidWorks 2009). Motion data was collected at 100 Hz (Vicon 612) during level walking and subsequently applied to a lower limb model (AnyBody Version 3.0) to calculate muscle forces. Both sets of data were then combined to create a subject-specific FE model (ANSYS 11.0) which was solved to determine relative contact areas, pressures, and deformations in the medial and lateral tibiofemoral compartments.Background
Method
Unicompartmental Knee Replacement (UKR) is an appealing alternative to Total Knee Replacement (TKR) when the patient has isolated compartment osteoarthritis (OA). A common observation post-operatively is radiolucency between the tibial tray wall and the bone. In addition, some patients complain of persistent pain following implantation with a UKR; this may be related to elevated bone strains in the tibia. The aim of this study was to investigate the mechanical environment of the tibia bone adjacent to the tray wall, following UKR, to determine whether this region of bone resorbs, and how altering the mechanical environment affects tibia strains. A finite element (FE) model of a cadaver tibia implanted with an Oxford UKR was used in this study, based on a validated model. A single static load, measured in-vivo during a step-up activity was used. There was a 1 mm layer of cement surrounding the keel in the cemented UKR, and the cement filled the cement pocket. In accordance with the operating procedure, no cement was used between the tray wall and bone. For the cementless UKR a layer of titanium filled the cement pocket. An intact tibia was used to compare to the cemented and cementless UKR implanted tibiae. The tibia was sectioned by the tray wall, defining the radiolucency zone (parallel to the vertical tray wall, 2 mm wide with a volume of 782.5 mm3), corresponding to the region on screened x-rays where radiolucencies are observed. Contact mechanics algorithms were used between all contacting surfaces; bonded contact was also introduced between the tray wall and adjacent bone, simulating a mechanical tie between them. Strain energy density (SED), was compared between the intact and implanted tibia for the radiolucency zone. Equivalent strains were compared on the proximal tibia between the intact and implanted tibia models. Forty patients (20 cemented, 20 cementless) who had undergone UKR were randomly selected from a database, and assessed for radiolucency.Introduction
Materials and methods
Anteromedial gonarthrosis is a common well described pattern of knee osteoarthritis with cartilage wear beginning in the anteromedial quadrant of the medial tibial plateau in the presence of an intact and functioning ACL. It is well known that mechanical factors such as limb alignment and meniscal integrity affect the progression of arthritis and there is some evidence that the morphology of the tibial plateau may be a risk factor in the development of this disease. The extension facet angle is the angle of the downslope of the anterior portion of the medial tibial plateau joint surface in relation to the middle portion on a sagittal view. If this is an important factor in the development of AMG there may be potential for disease modifying intervention. This study investigates if there is a significant difference in this angle as measured on MRI between a study cohort with early AMG (partial thickness cartilage damage and intact ACL) and a comparator control cohort of patients (no cartilage damage and ACL rupture). 3 Tesla MRI scans of 99 patients; 54 with partial thickness cartilage damage and 44 comparitors with no cartilage damage (acute ACL rupture) were assessed. The extension facet angle was measured (Osirix v3.6) using a validated technique on two consecutive MRI T2 sagittal slices orientated at the mid-coronal point of the medial femoral condyle. (InterClass Correlation 0.95, IntraClass Correlation 0.97, within subject variation of 1.1° and coefficient of variation 10.7%). The mean of the two extension angle values was used. The results were tabulated and analysed (R v2.9.1).Introduction
Methods
Iterative finite element (FE) models are used to simulate bone remodelling that takes place due to the surgical insertion of an implant or to simulate fracture healing. In such simulations element material properties are calculated after each iteration of solving the model. New material properties are calculated based on the results derived by the model during the last iteration. Once the FE model has gone through a number of such iterations it is often necessary to assess the remodelling that has taken place. The method widely used to do this is to analyse element Young's modulus plots taken at particular sections through the model. Although this method gives relevant information which is often helpful when comparing different implants, the information is rather abstract and is difficult to compare with patient data which is commonly in the form of radiographs. The authors suggest a simple technique that can be used to generate synthetic radiograph images from FE models. These images allow relatively easy comparisons of FE derived information with patient radiographs. Another clear advantage of this technique is that clinicians (who are familiar with reading radiographs) are able to understand and interpret them readily. To demonstrate the technique a three dimensional (3D) model of the proximal tibia implanted with an Oxford Unicompartmental Knee replacement was created based on CT data obtained from a cadaveric tibia. The model's initial element material properties were calculated from the same CT data set using a relationship between radiographic density and Young's modulus. The model was subject to simplified loading conditions and solved over 365 iterations representing one year of in vivo remodelling. After each iteration the element material properties were recalculated based on previously published remodelling rules. Next, synthetic anteroposterior radiographs were generated by back calculating radiographic densities from material properties of the model after 365 iterations. A 3D rectangular grid of sampling points which encapsulated the model was defined. For each of the elements in the FE model radiographic densities were back calculated based on the same relationships used to calculate material properties from radiographic densities. The radiographic density of each element was assigned to all the sampling grid points within the element. The 3D array of radiographic densities was summed in the anteroposterior direction thereby creating a 2D array of radiographic densities. This 2D array was plotted giving an image analogous to anteroposterior patient radiographs. Similar to a patient radiograph denser material appeared lighter while less dense material appeared darker. The resulting synthetic radiographs were compared to patient radiographs and found to have similar patterns of dark and light regions. The synthetic radiographs were relatively easy to produce based on the FE model results, represented FE results in a manner easily comparable to patient radiographs, and represented FE results in a clinician friendly manner.
The heat produced by drills, saws and PMMA cement in the handling of bone can cause thermal necrosis. Thermal necrosis could be a factor in the formation of a fibrous tissue membrane and impaired bony ingrowth into porous prostheses. This has been proposed to lead to non-union of osteotomies and fractures, the failure of the bone-cement interface and the failure of resurfacing arthroplasty. We compared three proprietary blades (the De Soutter, the Stryker Dual Cut and the Stryker Precision) in an in-vitro setting with porcine tibiae, using thermocouples embedded in the bone below the cutting surface to measure the increases in bone temperature. There was a significant (p=0.001) difference in the change in temperature (δT) between the blade types. The mean increase in temperature was highest for the De Soutter, 2.84°C (SD: 1.83°C, range 0.48°C to 9.30°C); mean δT was 1.81°C (SD: 1.00°C, range 0.18°C to 4.85°C) for the Precision and 1.68°C (SD: 0.95°C, range 0.24°C to 5.67°C). Performing paired tests, there was no significant difference in δT between the Precision and Dual Cut blades (p=0.340), but both these blades had significantly (p=0.003 for Precision vs De Soutter, p<0.001 for Dual Cut vs De Soutter) lower values for δT than the Dual Cut.
The results of the mobile bearing Oxford unicompartmental knee replacement (UKR) in the lateral compartment have been disappointing with a five year survival of 82%. Therefore, it is recommended that mobile bearings should not be used for lateral UKR. This low survivorship is primarily due to high dislocation rate, all occurring in the first year. A detailed analysis of the causes of bearing dislocation confirmed the elevated lateral tibial joint line to be a contributory factor. A new surgical technique was therefore introduced in which care was taken neither to remove too much bone from distal femur nor to over tighten the knee and thus ensure that the tibial joint line was not elevated. Other modifications to the technique were also introduced including use of a domed tibial component. The aim of this study is to compare the outcome of these iterations: the original series [series I], Series II with improved surgical technique and the domed tibial component [Series III].Introduction
Aim
Obesity has been considered a relative contra-indication in unicompartmental knee arthroplasty (UKA) due to fear of high wear rates, loosening and tibial collapse. The aim of this study was to investigate the impact of high body mass index (BMI) on ten-year survivorship and five-year functional outcome after Oxford UKA, a fully congruous mobile bearing design with large contact area and low wear rate. This prospective study examines a consecutive series of 595 knees (mean age 66 years, range: 33-88) undergoing Oxford UKA with a minimum 5-year follow-up. Patients were divided into three groups; Group I (Normal body weight), BMI <25 (n=171), Group II (overweight), BMI 25- 30 (n=264), and Group III (Obese), BMI ≥30 (n=160). The survivorship and functional outcome (as assessed by change in Oxford Knee Score [DeltaOKS]) and Knee Society Score (KSS) for all three groups were compared.Introduction
Methods
To investigate the linear penetration rate of the polyethylene bearing in unicompartmental knee arthroplasty at twenty years. The Phase 1 Oxford medial UKR was introduced in 1978 as a design against wear, with a fully congruous articulation. In 1987 the Phase 2 implant was introduced with new instrumentation and changes to the bearing shape. We have previously shown a linear penetration rate (LPR) of 0.02 mm/year at ten years in Phase 2, but that higher penetration rates can be seen with impingement. The aim of this study was to determine the 20 year in-vivo LPR of the Oxford UKR, using Roentgen Stereophotogrammetric Analysis (RSA).Purpose of study
Introduction
Kozinn and Scott have made recommendations about contra-indications for unicompartmental knee replacement (UKR). They suggest that patients younger than 60, weight > 82 kilograms, patients with exposed bone in patella-femoral compartment or patients who are physically active/perform heavy labour should not be offered a UKR. In addition, chondrocalcinosis is a contra-indication. These strict selection criteria are based on the experience with fixed bearing UKAs and are more intuitive than evidence based. The Oxford UKR has a fully congruous mobile bearing and has been shown to have minimal wear. Over the past 25 years, the Oxford Group has followed a standardised protocol for patient selection for UKR. We ignore patella-femoral joint pathology, chondrocalcinosis, patient's age, weight and activity level when deciding the suitability for UKR. Using the standardised indications, more than 1100 Oxford UKRs have been performed to date over the last 10 years. These patients are assessed pre-operatively and at regular intervals post-operatively in a dedicated research clinic. We present the results of these consecutive cases. Patients were classified into two groups: group I (satisfy Kozinn-Scott recommendations) and group II (outside recommendations).Introduction
Methods
In 12 patients, we measured the oxygen concentration in the femoral head-neck junction during hip resurfacing through the anterolateral approach. This was compared with previous measurements made for the posterior approach. For the anterolateral approach, the oxygen concentration was found to be highly dependent upon the position of the leg, which was adjusted during surgery to provide exposure to the acetabulum and femoral head. Gross external rotation of the hip gave a significant decrease in oxygenation of the femoral head. Straightening the limb led to recovery in oxygen concentration, indicating that the blood supply was maintained. The oxygen concentration at the end of the procedure was not significantly different from that at the start. The anterolateral approach appears to produce less disruption to the blood flow in the femoral head-neck junction than the posterior approach for patients undergoing hip resurfacing. This may be reflected subsequently in a lower incidence of fracture of the femoral neck and avascular necrosis.
To assess the incidence of radiolucency in cemented and cementless Oxford unicompartmental knee replacement at two years. Most unicompartmental knee replacements (UKRs) employ cement for fixation of the prosthetic components. The information in the literature about the relative merits of cemented and cementless UKR is contradictory, with some favouring cementless fixation and others favouring cemented fixation. In addition, there is concern about the radiolucency that frequently develops beneath the tibial component with cemented fixation. The exact cause of the occurrence of radiolucency is unknown but it has been hypothesised that it may suggest suboptimal fixation.Purpose of Study
Introduction
This study aims to investigate femoral blood flow during Metal-on-Metal Hip Resurfacing (MMHR) by monitoring oxygen concentration during the operative procedure. Patients undergoing MMHR using the posterior approach were evaluated. Following division of fascia lata, a calibrated gas-measuring electrode was inserted into the femoral neck, aiming for the supero-lateral quadrant of the head. Baseline oxygen concentration levels were detected after electrode insertion 2-3cm below the femoral head surface and all intra-operative measures were referenced against these. Oxygen levels were continuously monitored throughout the operation. Data from ten patients are presented. Oxygen concentration dropped most noticeably during the surgical approach and was reduced by 62% (Std.dev +/-26%) following dislocation and capsulectomy. Insertion of implants resulted in a further oxygenation decrease by 18% (Std.dev +/-28%). The last obtained measure before wound closure detected 22% (Std.dev +/-31%) of initial baseline oxygen levels. Variation between subjects was observed and three patients demonstrated a limited recovery of oxygen levels during implant insertion and hip relocation. Intra-operative measurement of oxygen concentration in blood perfusing the femoral head is feasible. Results in ten patients undergoing MMHR showed a dramatic effect on the oxygenation in the femoral head during surgical approach and implant fixation. This may increase the risk of avascular necrosis and subsequent femoral neck fracture. Future experiments will determine if less invasive procedures or specific positioning of the limb can protect the blood supply to femoral neck and head.
There have been many reports of metal ion levels measured in the bloodstream of patients after metal-on-metal hip replacement, and it is generally accepted that levels of cobalt (Co) and chromium (Cr) are elevated after these types of devices are implanted. However, it is not clear how to interpret these elevated levels; in particular what are the acceptable levels and what levels indicate that close monitoring of the patient is needed. Our aim was to establish the differences in metal ion levels between well functioning patients and those with clinical problems. We measured serum Co and Cr levels (microgram’s per litre or μg/l) using inductively coupled plasma mass spectrometry with a well established collection protocol of all patients attending follow-up clinics. Our inclusion criteria for this study were all patients unilaterally implanted with a metal-on-metal hip resurfacing with no other metallic implant; patients were categorized as either A. Well Functioning or B. Clinically Problematic (pain, reduced function, reduced ROM, negative x-ray findings) and differences in ion levels between these two groups were examined. Well functioning patient data was only included if measurements were made more than 12 months post-operatively to avoid run-in wear levels. Abduction angle was also measured from x-rays of the pelvis, and the frontal plane coverage arc of each implanted cup calculated (De Haan JBJS[Br] 2008;90(10):1291–7). There were a total of 519 patients, with 358 in Group A and 161 in Group B; patients had a variety of devices with Birmingham Hip Resurfacing (64%) and Conserve Plus (29%) being the most commonly implanted. To establish a guideline upper ion level value for well functioning implants the upper 75th percentile values for Co and Cr levels for Group A patients having 15 mm or more coverage arc were calculated. The risk of having clinical problems was calculated as function of metal ion levels higher or lower than these upper limits. The ion levels were significantly (Mann Whitney U p<
0.001) higher in Group B (mean [95% confidence intervals], Co 10.2 μg/l [5.9 to 14.5], Cr 10.3 μg/l [6.7 to 14.0]) compared to Group A (Co 2.3 μg/l [1.7 to 2.4], Cr 2.8 μg/l [2.3 to 3.4]). The well functioning upper limit for Co was 4.1 μg/l and for Cr was 5.2 μg/l. Metal ion levels greater than these upper limits were significantly (Chi-square p<
0.001) associated with the presence of clinical problems. The odds ratio for Co greater than 4.1 μg/l was 11.2 [95%CI 5.7 to 22.3] and that for Cr greater than 5.2 μg/l was 4.3 [95%CI 2.6 to 7.0]. There were significantly higher metal ion levels measured in patients with clinical problems after metal-on-metal hip resurfacing than those with well functioning hips. We have proposed upper acceptable limits for Co (4.1 μg/l) and Cr (5.2 μg/l) serum levels. Cobalt levels appear to be more reliable in predicting risk of clinical problems; levels greater than our proposed upper limit have 11 times the odds of developing clinical problems and patients with such levels should be followed closely.
6 patients with pseudo-tumours detected using ultrasound/MRI; 15 patients without pseudotumours. Three-dimensional lower limb motion analysis (12 camera Vicon System) was performed to estimate hip joint segment force during walking, chair-rising and stair-climbing. CT scans were used to determine each patient’s specific hip joint centre and acetabular component orientation. Edge-loading was defined to occur when a hip joint segment force vector/ cup intersection was located within 10% of the cup radius from the edge of the cup. Serum cobalt and chromium levels were analysed using Inductively-Coupled Plasma Spectrometer.
significantly higher median serum cobalt levels: 14.3ug/l (range 10.6–64.1) vs. 1.9ug/l (range 1.2–5.0), p<
0.001; significantly higher median serum chromium levels: 21.2ug/l (range 13.8–45.2) vs. 1.8ug/l (range 0.7–7.6), p<
0.001.
The intact femur geometry was derived from a CT dataset of a cadaveric femur and CT numbers were converted into a realistic distribution of material properties. The FE intact mesh was based on an experimentally validated mesh of a human femur. The femur was segmented into 22 neck sections. The loading condition was modelled to represent an instant at 10% of gait where all muscle forces were included. The femoral neck regions were compared between the models to evaluate the effect of notch sizes on stress distribution. Maximum tensile stresses were compared to the ultimate tensile stress (UTS) of cortical and cancellous bone.
This study investigates if there is a significant difference in this angle as measured on MRI between a study cohort with early AMG (partial thickness cartilage damage and intact ACL) and a comparator control cohort of patients (no cartilage damage and ACL rupture).
8 MoMHRA implants revised due to pseudotumour; 22 MoMHRA implants revised due to other reasons of failure (femoral neck fracture and infection). The linear wear of retrieved implants was measured using a Taylor-Hobson Roundness machine. The average linear wear rate was defined as the maximum linear wear depth divided by the duration of the implant in vivo.
significantly higher median linear wear rate of the femoral component: 8.1um/year (range 2.75–25.4um/year) vs. 1.79um/year (range 0.82–4.15um/year), p=0.002; and significantly higher median linear wear rate of the acetabular component: 7.36um/year (range1.61–24.9um/year) vs. 1.28um/year (range 0.18–3.33um/year), p=0.001. Similarly, differences were also measured in absolute wear values. The median absolute linear wear was significantly higher in the pseudotumour implant group:
21.05um (range 2.74–164.80um) vs. 4.44um (range 1.50–8.80um) for the femoral component, p=0.005; and 14.87um (range 1.93–161.68um) vs. 2.51um (range 0.23–6.04um) for the acetabular component, p=0.008. Wear on the acetabular cup components in the pseudotumour group always involved the edge, indicating edge-loading of the bearing. In contrast, edge-loading was observed in only one acetabular component in the non-pseudotumour group of implants. The deepest wear was observed well within the bearing surface for the rest of the non-pseudotumour group. The difference in the incidence of edge-loading between the two groups was statistically significant (Fisher’s exact test, p=0.03).
For the whole cohort, there was no significant difference in ion levels (Cr: p=0.092. Co=0.075) between cups positioned within Z3 (n=58) versus those outside (n=46 mean). Male patients with cups within Z3 (n=27) had lower ion levels in comparison to those outside Z3, which were significantly lower for Co (p=0.049) but not Cr (p=0.084). Female patients had similar levels within and out of Z3 for both ions (Cr: p=0.83, Co: p=0.84). However, patients with cups within Z1 (n=13) had significantly lower Co (p=0.005) and Cr (p=0.001) than those outside Z1 (n=95). Interestingly, Co levels were significantly lower in Z1 (n=13) in comparison to Z2 (n=33) (p=0.048) but Cr levels were not different (p=0.06).
The results of mobile bearing Oxford unicompartmental knee replacement (UKR) in the lateral compartment have been disappointing (five-year survival: 82%). Therefore, it is recommended that mobile bearings should not be used for lateral UKR. This low survivorship is primarily due to a high dislocation rate. A detailed analysis confirmed the elevated lateral tibial joint line to be a contributory factor to bearing dislocation. A new surgical technique was therefore introduced in which care was taken neither to remove too much bone from the distal femur nor to over tighten the knee and therefore ensure that the tibial joint line was not elevated. Other modifications included use of a domed tibial component. The aim of this study is to compare the outcome of these iterations: the original series (series I), those with improved surgical technique (series II) and the domed tibial component (series III). The primary outcome measure was bearing dislocation at one year. One year was chosen as all the dislocations in the first series occurred within a year. In the original series (n=53), implanted using a standard open approach, there were six dislocations in the first year, the average flexion 110°, and 95% had no/mild pain on activity. In the second series (n=65), there were 3 dislocations, the average flexion was 117°, and 80% had no/mild pain on activity. In the third series with the modified technique and a convex domed tibial plateau, there was one dislocation, average flexion was 125° and 94% had no/mild pain on activity. At four years the cumulative primary dislocation rates were 10%, 5% and 0% respectively, and were significantly different (p=0.04). The improved surgical technique and implant design has reduced dislocation rate to an acceptable level so a mobile bearing can now be recommended for lateral UKR.
Roentgen Stereophotogrammetric Analysis (RSA) can predict long-term outcome of prostheses by measuring migration over time. The Exeter femoral stem is a double-tapered highly polished implant and has been shown to subside within the cement mantle in 2 year RSA studies. It has a proven track record in terms of long-term survivorship and low revision rates. Several studies have demonstrated excellent clinical outcomes following its implantation but this is the first study to assess stem migration at 10 years, using RSA. This is a single-centre study involving 20 patients (mean age: 63 years, SD=7) undergoing primary total hip replacement for degenerative osteoarthritis using the lateral (Hardinge) approach. RSA radiographs were taken with the patient bearing full weight post-operatively, at 3, 6, 12 months and at 2, 5 and 10 years follow-up. The three-dimensional migration of the Exeter femoral stem was determined. The mean Oxford Hip Score at 10 years was 43.4 (SD=4.6) and there were no revisions. The stems subsided and rotated internally during a 10-year period. The mean migrations of the head and tip of the femoral stem in all three anatomic directions (antero-posterior, medio-lateral &
supero-distal) were 0.69 mm posterior, 0.04 mm lateral and 1.67 mm distal for the head and 0.20 mm anterior, 0.02 mm lateral and 1.23 mm distal for the tip. The total migration at 10 years was 1.81 mm for the head and 1.25 mm for the tip. The Exeter femoral stem exhibits migration which is a complex combination of translation and rotation in three dimensions. Comparing our 10 year with our previous 2 year migration results, the Exeter stems show continued, but slow distal migration and internal rotation. The subsidence continues to compress the cement and bone-cement interface which maintains secure fixation in the long term.
About ten years ago we introduced sophisticated instrumentation and an increased range of component sizes for the Oxford unicompartmental knee replacement (UKR) to facilitate a minimally invasive surgical (MIS) approach. The device is now routinely implanted through an incision from the medial pole of the patella to the tibial tuberosity. This has resulted in a more rapid recovery and an improved functional result. As the access to the knee is limited there is a concern that the long term results may be compromised. The aim of this study was to determine the 10 year survival. A prospective follow up of all Phase 3 minimally invasive Oxford UKR implanted by two senior authors (DWM &
CAFD) has been undertaken. So far 1015 UKRs have been implanted for anteromedial osteoarthritis. All patients received a cemented implant through a MIS approach and were followed up prospectively by an independent observer. The data was collected prospectively regarding pre-operative status, complications and clinical as well as functional outcome at predetermined intervals. The average age of patients was 66.4 years (range: 33 – 88) with mean Oxford Knee Score 41 (SD: 7.9) at the time of last follow up, Knee Society Score (objective) of 84 (SD: 13) and Knee Society Score (functional) of 83 (SD: 21). At ten years the survival of this cohort is 96%. There were 22 revisions including 7 for progression of arthritis, 5 for infection, 5 for bearing dislocation, 4 for unexplained pain and one for rupture of ACL secondary to trauma. We conclude that the Oxford Knee can be implanted reliably through a minimally invasive approach, giving excellent long term results.
to determine the prevalence of asymptomatic pseudotumours after MoMHRA; and to measure Co and Cr ion levels as well as lymphocyte proliferation responses to Ni, Co and Cr (the principal elements in the CoCr alloy used in MoMHRA) in MoMHRA patients with and without asymptomatic pseudotumours.
Metal Ion Levels – The presence of pseudotumour was associated with significantly higher median serum cobalt levels (9.2mg/L vs. 1.9mg/L, p<
0.001), chromium levels (12.0mg/L vs. 2.1mg/L, p<
0.001), hip aspirate cobalt levels (1182 mg/L vs. 86.2mg/L, p=0.003), and aspirate chromium levels (883mg/L vs. 114.8mg/ L, p=0.006), as well as with inferior functional scores (OHS 41 vs. 47 p<
0.001). There was no significant difference in acetabular cup inclination angle (p=0.51). Lymphocyte Reactivity: A higher incidence and level of enhanced lymphocyte reactivity to Ni (p=0.001), but not to Co or Cr (the principal elements in the CoCr alloy used in metal-on-metal hip resurfacing implants), was found in patients with MoMHRA compared to the patients without MoM implants. However, lymphocyte reactivity to Co, Cr and Ni did not significantly differ in patients with pseudotumours compared to those patients without pseudotumours. Conclusion: The prevalence of asymptomatic pseudotumours in females was high, especially in females with bilateral MoMHRA implants (30%). The patients with ‘asymptomatic’ pseudotumours were in fact mildly symptomatic. Lymphocyte reactivity to Co, Cr and Ni did not differ in patients with pseudotumour compared to those patients without pseudotumours, suggesting that systemic hypersensitivity type IV reactions, mediated by lymphocyte reactivity to these metals, is not the dominant mechanism in pathogenesis of the soft tissue pseudotumours. Furthermore, pseudotumours were not detected in those patients who had normal levels of cobalt and chromium ions. This suggests that pseudotumours do not occur if MoM articulations are well functioning. Therefore, pseudotumours are likely to be a biological consequence of the large amount of metal debris generated in vivo due to excessive wear.
Our aim was to investigate the molecular features of progressive severities of cartilage damage, within the phenotype of Anteromedial Gonarthrosis (AMG). Ten medial tibial plateau specimens were collected from patients undergoing unicompartmental knee replacements. The cartilage within the area of macroscopic damage was divided into equal thirds: T1(most damaged), to T3 (least damaged). The area of macroscopically undamaged cartilage was taken as a 4th sample, N. The specimens were prepared for histological (Safranin-O and H&
E staining) and immunohistochemical analysis (Type I and II Collagen, proliferation and apoptosis). Immunoassays were undertaken for Collagens I and II and GAG content. Real time PCR compared gene expression between areas T and N. There was a decrease in OARSI grade across the four areas, with progressively less fibrillation between areas T1, T2 and T3. Area N had an OARSI grade of 0 (normal). The GAG immunoassay showed decreased levels with increasing severity of cartilage damage (p<
0.0001). There was no significant difference in the Collagen II content or gene expression between areas. The Collagen I immunohistochemistry showed increased staining within chondrocyte pericellular areas in the undamaged region (N) and immunoassays showed that the Collagen I content of this macroscopically and histologically normal cartilage, was significantly higher than the damaged areas (p<
0.0001). Furthermore, real time PCR showed a significant increase in Collagen I expression in the macroscopically normal areas compared to the damaged areas (p=0.04). In AMG there are distinct areas, demonstrating progressive cartilage loss. We conclude that in this phenotype the Collagen I increase, in areas of macroscopically and histologically normal cartilage, may represent very early changes of the cartilage matrix within the osteoarthritic disease process. This may be able to be used as an assay of early disease and as a therapeutic target for disease modification or treatment.
Despite the satisfactory short-term implant survivor-ship, there is an increasing concern that the metal-on-metal hip resurfacing arthroplasty (MoMHRA) release large amount of very small wear particles and metal ions. The periprosthetic soft-tissue masses such as pseudotumours are being increasingly reported. These were found be locally destructive, requiring revision surgery in most patients. It has been suggested that either an immune reaction or cytotoxic effect of chromium(Cr) or cobalt(Co) may play a role in its aetiology. However, the effect of the phagocytosis of implant-associated metal nanoparticles on macrophages has not been elucidated. The aim of this study was to investigate the in vitro viability and proliferative response of murine macrophages to clinically relevant metal nanoparticles and ions.
At the end of day 1 and 4, two methods were used to quantify cell proliferation and viability. The AlamarBlue assay(Invitrogen) incorporates a fluorimetric growth indicator and the fluorescence signal correlates with metabolic activity of the cells. LIVE/DEAD stain kit(Molecular Probes) contains two fluorescent dyes to stain living cells green and dead cells red. The viability was calculated by the number of live cells divided by total cell numbers. Inter-group comparisons were performed using one-way ANOVA with Tukey post hoc test. Differences at p<
0.05 were considered to be significant.
Recently, a series of locally destructive soft tissue pseudotumour has been reported in patients following metal-on-metal hip resurfacing arthroplasty (MoMHRA), requiring revision surgery in a high percentage of patients. Based on the histological evidence of lymphocytic infiltration, a delayed hypersensitivity reaction to nickel (Ni), chromium (Cr) or cobalt (Co) has been suggested to play a role in its aetiology. The aim of this study was to investigate the incidence and level of hypersensitivity reaction to metals in patients with pseudotumour.
Group 1: MoMHRA patients with pseudotumours, detected on the ultrasound and confirmed with MRI (n=6, 5 F:1 M, mean age 53 years); Group 2: MoMHRA patients without pseudotumours (n=13, 7 F:6 M, mean age 55 years); and Group 3: age-matched control subjects without metal implants (n=6, 4 F:2 M, mean age 54 years). Lymphocyte transformation tests (LTT) were used to measure lymphocyte proliferation responses to metals. Peripheral blood mononuclear cells were isolated from heparinized blood samples using standard Ficoll–Hypaque® (Pharmacia). The PBMC were cultured at a cell density of 106 cells/mL. Culture was set up in the presence of either:
medium alone; nickel chloride (Sigma; 10-4M-10-6M); cobalt chloride (10-4M-10-6M); and chromium chloride (10-4M-10-6M). After 5 days of culture, cells were pulsed with [3H]-thymidine and proliferation was assessed by scintillation counting. The stimulation index (SI) was calculated by the ratio of mean counts per minute of stimulated to unstimulated cultures. A SI value of greater than 2.0 was interpreted as a positive result.
Tribological studies of hip arthroplasty suggest that larger diameter metal-on-metal (MOM) articulations would produce less wear than smaller diameter articulations. Other advantages using these large femoral heads implants include better stability with lower dislocation rates and improved range of motion. The aim of the present study was to compare chromium (Cr), cobalt (Co) and titanium (Ti) ion concentrations up to 1-year after implantation of different large diameter MOM total hip arthroplasty (THA).
Statistical group comparison revealed significant difference for Cr (p=0.006), Co (p=0.047) and Ti (p=<
0.001). With Biomet implants presenting the best results for Cr and Co and Zimmer the highest Ti level.
Metal on Metal Hip Resurfacing Arthroplasty (MoMHRA) has gained popularity due to its perceived advantages of bone conservation and relative ease of revision to a conventional THR if it fails. Known MoMHRA-associated complications include femoral neck fracture, avascular necrosis/collapse of the femoral head/neck, aseptic loosening and soft tissue responses such as ALVAL and pseudotumours. This study’s aim was to assess the functional outcome of failed MoMHRA revised to THR and compare it with a matched cohort of primary THRs.
Patello-femoral instability (PFI) affects 40 individuals per 100,000 population and causes significant morbidity. The causes of patello-femoral instability are multi-factorial, and an isolated anatomical abnormality does not necessarily indicate instability. Patello-femoral subluxation ranges from 0% (stable patella tracking) to 100% (dislocation) and there is an established relationship between the amount of subluxation and anterior knee pain. Traditionally, magnetic resonance (MR) imaging and standard radiographs are used to guide the clinician towards a suitable corrective procedure for PFI. The multi-factorial nature of patello-femoral instability is not addressed with current imaging techniques. This study aims to address which anatomical variables assessed on MR images are most relevant to patello-femoral subluxation. This information will aid surgical decision making, particularly in selecting the most appropriate reconstructive surgery. A retrospective analysis of MR studies of 60 patients with suspected patello-femoral instability was performed. All patients were graded for degree of subluxation using a dynamic MR scan. The patient scans were assessed for the presence of a specific range of anatomical variables:
patella alta, (modified Insall-Salvatti) patella type (Wiberg classification) trochlea sulcus angles for bone and cartilage surfaces the distance of the vastus medialis obliquis (VMO) muscle from the patella trochlea and patella cartilage thickness the horizontal distance between the tibial tubercle and the midpoint of the femoral trochlea (TTD) patella engagement – the percentage of the patella height that is captured in the trochlea groove in full extension. The Wilk’s Lambda test for multi-variate analysis was used to establish whether any relationship was present between the degree of patello-femoral instability and bony or soft tissue anatomical variables. Non-parametric statistical tests were applied across the groups and within the groups to assess their relative significance. The following variables showed a significant relationship with patellofemoral subluxation; distance of the VMO from the patella (<
0.001), TTD (<
0.001), patella engagement (0.001), sulcus angles (0.004) and patella alta (0.005). This study agrees with previous work showing a significant correlation between subluxation and trochlea sulcus angle and TTD. This is the first study to establish a significant correlation between patella engagement and radiological instability. The lower the percentage engagement of the patella in the trochlea, the greater the degree of patello-femoral instability. Patella engagement showed a more significant relationship with subluxation than patella alta. We report a new method of predicting patello-femoral instability by measuring the overlap of the patella in the trochlea groove.
100% of medial compartments showed full thickness anteromedial loss with preservation of the posteromedial cartilage. When present, the meniscus was extruded in 96% of cases. 90% of lateral compartments were normal and none had full thickness cartilage loss. However 10% showed high signal in the tibial plateau. There was a highly reproducible pattern of osteophyte formation; 94% posteromedial and posterolateral aspect of medial femoral condyle; 90% medial tibial; 80% medial femoral and 84% lateral intercondylar notch.
patients’ pre-operative demographics for age, weight, height, BMI, intraoperative variables such as the operating surgeon (n=2), insert and component sizes, and clinical assessment criteria including pre-operative and five-year post-operative Oxford knee (OKS) and Tegner (TS) scores.
In finite element (FE) analysis of long bones it is now common practice to calculate the material properties based on CT data. Although a unique material property is calculated for each element, assigning each element an individual material property results in excessively large models. To avoid this, it is usual to group the elements based on their material properties and to assign each group a single material property (Zannoni 1998). No study has analysed the effect the number of material properties used in a long bone FE model has on the accuracy of the results. The aim of this study was to evaluate the variation in the calculated mechanical environment as a function of the number of material properties used in an FE model. An FE mesh of a cadaveric human tibia containing 47,696 ten-node tetrahedron elements and 75,583 nodes was created using CT scans. Material properties were calculated for each element of the mesh based on previous work (Rho 1995, 1996). Eleven FE models were created by varying the number of groups (1, 2, 4, 8, 16, 32, 64, 128, 256, 512, 1024) the elements were divided into. A single material property was assigned to each group. All models were subject to an axial point load of 300N applied on the medial condyle of the tibial plateau while the distal end was fixed. The variation in maximum and minimum principal strains and deflections, at 17 well distributed surface nodes and at 65 randomly distributed nodes within the bone were plotted against the number of element groups. The total strain energy was also plotted against the number of groups. The errors for strain, deflection, and total strain energy were calculated for each model assuming that the model using 1024 element groups was accurate. The parameter to converge with the least number of element groups was the total strain energy. At 512 element groups the error was less than 0.001% (0.7% for the two material model). The next to converge were the displacements. Using 512 materials the maximum error in displacement at the surface nodes was 0.001% (4.7% for the 2 material model), while for the internal nodes the maximum error was 0.53% (36.7% for the 2 material model). The least convergence occurred for principal strains. The maximum errors when 512 materials were used were 1.06% (57.7% for the 2 material model) and 3.02% (104.5% for the 2 material model) for the surface and the internal nodes respectively. This study demonstrates the relationship between the accuracy of calculated mechanical environment and the number of material properties assigned to the model. While this study will allow the analyst to make an informed decision on the number of material properties for modelling the human tibia it also helps examine the validity of previous studies which, usually due to limited resources, used fewer material properties.
Metal-on-metal (MoM) bearing technology, made of cobalt-chromium (Co-Cr) alloys, is being used in anticipation of extending the durability of hip replacements. Increasingly, concern has been expressed that long term exposure to Co2+ and Cr3+ could cause DNA damage and immune dysfunction; specifically a reduction in the circulating number of CD8+ cytotoxic cells. More recently, we reported that Co2+ and Cr3+ affected the differentiation of osteoclast precursors into bone-resorbing osteoclasts. Despite these observations the effects of metal ions on osteoblast activity have been poorly investigated. The aim of the current study was to elucidate the effects of various metal ions on osteoblast activity in vitro. Cells of the human osteosarcoma cell line SaOS-2 were cultured in the presence of 0, 1, 10 and 100 μM Co2+ and Cr3+. The morphology, viability, cytokine release (TNFalpha, IL-1beta, IL-6, LIGHT, MIP-1alpha and VEGF) and alkaline phosphatase activity were investigated after 24h and 48h in contact with metal ions. Finally the capacity of SaOS-2 to produce and mineralize a new bone matrix was assessed by the Alizarin red method. All experiments were repeated at least 5 times and the differences between each were determined using non-parametric Mann-Whitney test. Compared to untreated cultures, although the morphology looked normal after 48h, the viability indicated that Co2+ and Cr3+ ions at high concentrations induced some significant and irreversible damages to the osteoblast cells. Interestingly, any of the cytokines investigated were released in contact with metal ions after 24h or 48h. The alkaline phosphatase activity was significantly increased by low concentrations of Co2+ and decreased by high concentrations of Cr3+ after 24h and 48h. Moreover, the degree of mineralization of a new bone matrix in vitro was significantly reduced when the SaOS-2 cells were exposed to high concentrations of Cr3+, but significantly increased when they were exposed to Co2+. Our results indicated that irreversible damages are caused to the cells as soon as 24h with high concentrations of metal ions. For osteoblasts cells, Co2+ appeared to be less toxic than Cr3+ at high concentrations. This study was supported by Furlong Research Charitable Foundation
Kinematic data from in-vivo fluoroscopy measurements during a step-up activity was used to determine the relative tibial-femoral position as a function of knee flexion angle for each model. Medial and lateral force distribution was adapted from loads measured in-vivo with an instrumented implant during a step-up activity. The affect that varying the bearing thickness has on the stresses in the bearing was investigated. In addition, varus-valgus mal-alignment was investigated by rotating the femoral component through 10 degrees.
Tibial lesion: In lateral OA, the midpoint of lesions was 2.0mm (SD:6.5) posterior to the reference line passing through the mid-coronal plane of the resected tibia. This was located significantly more posterior (p=0.038) than midpoint in medial OA, which was 2.2mm (SD:5.7) anterior to the reference line. Knee Flexion Angle: In lateral OA, the midpoint of lesions was on average at 40° flexion and sites of smaller lesions were very variable. The lesion expanded both anteriorly and posteriorly. In medial OA, smaller femoral lesions occurred in full extension and extended further posteriorly with disease progression. No significant difference was demonstrated in medial and lateral localisation of the lesions.