Introduction. Limb-length discrepancy (LLD) is a common postoperative complication after total hip arthroplasty (THA). This study focuses on the correlation between patients’ perception of LLD after THA and the anatomical and functional
Introduction. Leg length discrepancy (LLD) in patients with unilateral developmental dysplasia of the hip (DDH) can be problematic for both patients and surgeons. Patients can acquire gait asymmetry, back pain, and arthritis. Surgical considerations include timing of correction and arthroplasty planning. This study audits standing long leg films performed at skeletal maturity in our patients. The aim of this study is to identify if surgical procedure or AVN type could predict the odds of needing an LLD Intervention (LLDI) and influence our surveillance. Materials and Methods. Hospital database was searched for all patients diagnosed with DDH. Inclusion criteria were patients with appropriately performed long leg films at skeletal maturity. Exclusion criteria were patients with non DDH pathology, skeletally immature and inadequate radiographs. All data was tabulated in excel and SPSS was used for analysis. Traumacad was used for measurements and AVN and radiologic outcome grades were independently classified in duplicate. Results. 110 patients were identified. The mean age of follow-up was 15 years with final average LLD of 1mm(±5mm). The DDH leg tended to be longer and length primarily in the femur. 31(28.2%) patients required an LLDI. 19 Patients had a final LLD >1.5cm. There was no statistical significant difference in the odds of needing an LLDI by type of surgical procedure or AVN. AVN type 4 was associated with greatest odds of intervention. The DDH leg was more likely to require ipsilateral epiphysiodesis or contralateral lengthening in Type 1 and 2 AVN. Conclusions. The DDH leg tends to be longer,
Introduction. While THA is associated with positive results and long-term improvement in patient quality of life, outcomes are nonetheless associated with adverse events and post-procedural deficits related to discrepancies in
Objective. Open-wedge high tibial osteotomy (OWHTO) involves performing a corrective osteotomy of the proximal tibia and removing a wedge of bone to correct varus alignment. Although previous studies have investigated changes in
Typical devices to limit
Introduction. Leg length discrepancy is a significant concern after total hip replacement (THR). We hypothesised that the intra-operative use of a navigation system was able to accurately control the
Summary. The mathematical model has proven to be highly accurate in measuring
Introduction:
Introduction:. High tibial osteotomy (HTO) is a common treatment for medial compartment arthritis of the knee in younger, more active patients. The HTO shifts load away from the degenerative medial compartment and into the lateral compartment. This change can be accomplished with either a lateral closing or a medial opening wedge HTO. An HTO also potentially affects
Introduction.
We have developed a technique with the underlying principle being that the difference in height between what is removed and what is inserted will determine the
Introduction. One of the more common complaints from patients in their post-operative total knee arthroplasty (TKA) is the perceived feeling of the operative leg feeling longer than the non-operative leg. Studies have shown that the leg length discrepancies may occur in up to 80% of patients following unilateral TKA patients. The purpose of this study was to determine the incidence of leg length discrepancy (LLD) after primary TKA as well as determine the correlation between deformity and incidence of LLD. Methods. We retrospectively reviewed 1108 patients who underwent a primary unilateral TKA at a single institution. 97 patients were excluded for lack of imaging, prior total hip replacement or body mass index greater than 40 kg/m2. Hip to ankle biplanar radiographs were obtained pre-operative and 6 weeks postoperatively for all patients. Two independent observers measures
Aims. There is no consensus about the best method of achieving equal
leg lengths at total hip arthroplasty (THA) in patients with Crowe
type-IV developmental dysplasia of the hip (DDH). We reviewed our
experience of a consecutive series of patients who underwent THA
for this indication. Patients and Methods. We retrospectively reviewed 78 patients (86 THAs) with Crowe
type-IV DDH, including 64 women and 14 men, with a minimum follow-up
of two years. The mean age at the time of surgery was 52.2 years
(34 to 82). We subdivided Crowe type-IV DDH into two major types
according to the number of dislocated hips, and further categorised
them into three groups according to the occurrence of pelvic obliquity
or spinal curvature. Leg length discrepancy (LLD) and functional
scores were analysed. Results. Type-I included 53 patients with unilateral dislocation, in which
25 (category A) had no pelvic obliquity or spinal deformity, 19
(category B) had pelvic obliquity with a compensated spinal curvature
and nine (category C) had pelvic obliquity and decompensated spinal
degenerative changes. Type-II included 25 patients with one dislocated and one dysplastic
hip, in which there were eight of category A, 15 of category B and
two of category C. Pre-operatively, there were significant differences between the
anatomical and functional LLD in type-IB (p = 0.005) and -IC (p
<
0.001), but not in type-IA, -IIA or -IIB. Post-operatively, bony LLD increased significantly in types-IB,
-IC and -IIB, whereas functional LLD decreased significantly in
each type except for IIA. The mean functional LLD decreased from
30.7 mm (standard deviation (. sd. ) 18.5) pre-operatively
to 6.2 mm (. sd. 4.4) post-operatively and the mean anatomical
LLD improved from 35.8 mm (. sd. 19.7) pre-operatively to
12.4 mm (. sd. 8.3) post-operatively. Conclusion. Pelvic and spinal changes are common in patients with Crowe type-IV
DDH and need to be taken into consideration when planning THA, in
order to obtain equal
Introduction: Modular prostheses were first developed for use in total hip arthroplasty (THA) in the 1980s as a potential solution to the problem of
Introduction.
Background. Leg length discrepancy real or perceived remains an important source of patient dissatisfaction after a total hip replacement. Pre-operative templating and intra-operative measurement has to be used to ensure an accurate restoration of the normal centre of rotation of the hip as well as equal
Background. Total hip arthroplasty for Crowe type IV developmental dysplasia of the hip is a technically demanding procedure. Restoration of the anatomical hip center frequently requires limb lengthening in excess of 4 cm and increases the risk of neurologic traction injury. However, it can be difficult to predict potential
Introduction
Introduction/Aims: Early results of a prospective randomised control trial suggested improved position of components implanted during primary hip replacement. The aim of this study is to definitively show the benefit of computer aided navigation in hip arthroplasty with regard to acetabular component position, stem position and
There has been controversy about whether limb length discrepancy (LLD) affects outcome after total hip replacement (THR). We examined input variables and outcomes of over 1200 patients who received primary THR with the Exeter stem and a variety of acetabular components in the Exeter Primary Outcomes Study. This was a non randomized prospective multi centre study. We examined whether specific groups of patients or surgeons were more likely to have LLD at one year after surgery. Data for
Inaccurate component placement during total hip arthroplasty (THA) can have significant and costly consequences. Malpositioning of the acetabular cup components can lead to dislocation and revision surgery, while postoperative discrepancies in
Leg-length inequality is not uncommon following primary total hip arthroplasty and can be distressing to the patient. An excellent clinical result with respect to pain relief, function, component fixation, range of motion and radiographic appearance can be transformed into a surgical failure because of patient dissatisfaction due to leg-length inequality. Postoperative leg-length discrepancy was determined radiographically for 200 patients who had had a primary custom total hip arthroplasty. In all cases the opposite hip was considered to have a normal joint center. The femoral component was designed and manufactured individually for each patient using screened marker x-rays. A graduated calliper was used at the time of surgery to control depth of femoral component insertion. The transverse acetabular ligament was used to control placement of the acetabular component and therefore restore acetabular joint center. Using this method 94% of subjects had a postoperative leg-length discrepancy that was 6mm or less when compared to the normal side (average, +0.38mm). The maximum value measured for leg-length discrepancy was +/−8mm. We describe a simple technique for controlling
Objectives/Background: Long-term outcome in THR is multifactorial influenced. Malpositioning leads to complications as early loosening,
Introduction. Limb length discrepancy after THA can result in medicolegal litigation. It can create discomfort for the patient and potentially cause back pain or affect the longevity of the implant. Some patients tolerate the length inequality better compared to others despite difference in anatomical femoral length after surgery. Methods and materials. We analyzed the 3D EOS images of 75 consecutive patients who underwent primary unilateral THA (27 men, 48 women). We measured the 3D length of the femur and tibia (anatomical length), the 3D global anatomical length (the sum of femur and tibia anatomical lengths), the 3D functional length (center of the femoral head to center of the ankle), femoral neck-shaft angle, hip-knee-ankle angle, knee flexum/recurvatum angle, sacral slopes and pelvic incidence. We correlated these parameters with the patient perception of the
Introduction: Dislocation is the most common complication resulting in re-operation after total hip arthroplasty. This study investigates the association between acetabular prosthesis position, changes in femoral offset and
Incorrect restoration of
INTRODUCTION. Leg length discrepancy following total hip arthroplasty (THA) can be functionally disabling for affected patients and can lead on to litigation issues. Assessment of limb length discrepancy during THA using traditional methods has been shown to produce inconsistent results. The aim of our study was to compare the accuracy of navigated vs. non navigated techniques in limb length restoration in THA. METHODS. A dataset of 160 consecutive THAs performed by a single surgeon was included. 103 were performed with computer navigation and 57 were non navigated. We calculated limb length discrepancy from pre and post op radiographs. We retrieved the intra-operative computer generated limb length alteration data pertaining to the navigated group. We used independent sample t test and descriptive statistics to analyse the data. RESULTS. The two subgroups were matched for age, diagnosis and preoperative leg length discrepancy. The mean age was 69.12 (37–89, SD-8.3) and the mean BMI was 29 (19–44, SD-5.03). The mean post op limb length discrepancy in the non navigated group was 5 mm (SD-6) as compared to mean of 3.5mm (SD-6.5) for the computer navigated group. This difference was statistically significant (p<0.04). 18% of patients in the non navigated group had a limb length discrepancy of >10 mm as compared to 12% in the navigated group. There was no statistically significant difference between the computer predicted
Temporary epiphysiodesis (ED) is commonly applied in children and adolescents to treat leg length discrepancies (LLDs) and tall stature. Traditional Blount staples or modern two-hole plates are used in clinical practice. However, they require accurate planning, precise surgical techniques, and attentive follow-up to achieve the desired outcome without complications. This study reports the results of ED using a novel rigid staple (RigidTack) incorporating safety, as well as technical and procedural success according to the idea, development, evaluation, assessment, long-term (IDEAL) study framework. A cohort of 56 patients, including 45 unilateral EDs for LLD and 11 bilateral EDs for tall stature, were prospectively analyzed. ED was performed with 222 rigid staples with a mean follow-up of 24.4 months (8 to 49). Patients with a predicted LLD of ≥ 2 cm at skeletal maturity were included. Mean age at surgery was 12.1 years (8 to 14). Correction and complication rates including implant-associated problems, and secondary deformities as well as perioperative parameters, were recorded (IDEAL stage 2a). These results were compared to historical cohorts treated for correction of LLD with two-hole plates or Blount staples.Aims
Methods
Leg length discrepancy (LLD) is a common sequalae of limb reconstruction procedures. The subsequent biomechanical compensation can be directly linked to degenerative arthritis, lower back pain, scoliosis and functional impairment. It becomes particularly problematic when >2cm, established as a clinical standard. This two-arm experimental study assesses how reliable an iPhone application is in the measurement of LLD at different distances in control and LLD patients. 42 participants were included in the study, divided evenly into 21 control and 21 LLD patients. A standardised measurement technique was used to obtain TMM and iPhone application measurements, taken at a distance of 0.25m, 0.50m and 0.75m.Introduction
Materials and Methods
The aim of this study was to examine whether hips with unilateral osteoarthritis (OA) secondary to developmental dysplasia of the hip (DDH) have significant asymmetry in femoral length, and to determine potential related factors. We enrolled 90 patients (82 female, eight male) with DDH showing unilateral OA changes, and 43 healthy volunteers (26 female, 17 male) as controls. The mean age was 61.8 years (39 to 93) for the DDH groups, and 71.2 years (57 to 84) for the control group. Using a CT-based coordinate measurement system, we evaluated the following vertical distances: top of the greater trochanter to the knee centre (femoral length GT), most medial prominence of the lesser trochanter to the knee centre (femoral length LT), and top of the greater trochanter to the medial prominence of the lesser trochanter (intertrochanteric distance), along with assessments of femoral neck anteversion and neck shaft angle.Aims
Patients and Methods
Aims. Perthes’ disease (PD) often results in femoral head deformity and leg length discrepancy (LLD). Our objective was to analyze femoral morphology in PD patients at skeletal maturity to assess where the LLD originates, and evaluate the effect of contralateral epiphysiodesis for length equalization on proximal and subtrochanteric femoral lengths. Methods. All patients treated for PD in our institution between January 2013 and June 2020 were reviewed retrospectively. Patients with unilateral PD, LLD of ≥ 5 mm, and long-leg standing radiographs at skeletal maturity were included. Total
Aims. Achieving accurate implant positioning and restoring native hip biomechanics are key surgeon-controlled technical objectives in total hip arthroplasty (THA). The primary objective of this study was to compare the reproducibility of the planned preoperative centre of hip rotation (COR) in patients undergoing robotic arm-assisted THA versus conventional THA. Methods. This prospective randomized controlled trial (RCT) included 60 patients with symptomatic hip osteoarthritis undergoing conventional THA (CO THA) versus robotic arm-assisted THA (RO THA). Patients in both arms underwent pre- and postoperative CT scans, and a patient-specific plan was created using the robotic software. The COR, combined offset, acetabular orientation, and leg length discrepancy were measured on the pre- and postoperative CT scanogram at six weeks following surgery. Results. There were no significant differences for any of the baseline characteristics including spinopelvic mobility. The absolute error for achieving the planned horizontal COR was median 1.4 mm (interquartile range (IQR) 0.87 to 3.42) in RO THA versus 4.3 mm (IQR 3 to 6.8; p < 0.001); vertical COR mean 0.91 mm (SD 0.73) in RO THA versus 2.3 mm (SD 1.3; p < 0.001); and combined offset median 2 mm (IQR 0.97 to 5.45) in RO THA versus 3.9 mm (IQR 2 to 7.9; p = 0.019). Improved accuracy was observed with RO THA in achieving the desired acetabular component positioning (root mean square error for anteversion and inclination was 2.6 and 1.3 vs 8.9 and 5.3, repectively) and
Aims. This study aimed to evaluate the accuracy of implant placement with robotic-arm assisted total hip arthroplasty (THA) in patients with developmental dysplasia of the hip (DDH). Methods. The study analyzed a consecutive series of 69 patients who underwent robotic-arm assisted THA between September 2018 and December 2019. Of these, 30 patients had DDH and were classified according to the Crowe type. Acetabular component alignment and 3D positions were measured using pre- and postoperative CT data. The absolute differences of cup alignment and 3D position were compared between DDH and non-DDH patients. Moreover, these differences were analyzed in relation to the severity of DDH. The discrepancy of
With the knee flexed, a 1 cm difference produced a 3 % increase in loading. This was significant (P<
0.05). All subsequent increases were also significant. The largest increase in load was observed between 1 cm &
2 cm (+5 %). At 6cm the left leg load was 70.9 %. With the pelvis tilted, there were smaller increases in loading. These did not become significant until a difference of 5 cm. The maximum load was 62.1 % at 6 cm.
At Sheffield Children’s Hospital 40 children with leg length discrepancies (caused variously by sepsis, trauma, hemihypertrophy, congenital longitudinal deficiencies) were assessed using three clinical methods: measuring blocks in the standing erect position, supine measurement from the anterior superior iliac spine to the medial malleolus, and prone measurement with the knees flexed, which allowed separate measurement of femoral and tibial discrepancies. All were then subjected to comparative CT scanogram. The mean age of the 24 boys and 16 girls was 10 years (5 to 16). Children with abnormal pelvic architecture or a fixed pelvic obliquity were excluded from the study. The mean clinical length discrepancy was 29 mm (0 to 80 mm). The mean CT scanogram measurement was 26.4 mm (0 to 75 mm). The mean difference between clinical measurements taken prone and CT scanogram measurements was only 3.6 mm (0 to 14). There was little difference in the accuracy of measuring femoral and tibial discrepancies clinically or by CT scanogram. The prone method of measurements is a useful adjunct to Staheli’s rotational profile in the prone position.
In previous congress of ISTA in Hawaii, we reported the results about accuracy of the cup center position in our image-free navigation system. In the new version of our navigation system, leg elongation and offset change as well as cup center position can be navigated. In this study, we therefore investigated the accuracy of cup center position, leg elongation and offset change. Twenty four THA operations were performed with using the image-free OrthoPilot THA3.1 dysplasia navigation system (B. Braun Aesculap, Tuttlingen, Germany) between August 2009 and December 2009 by three experienced surgeons. In this system, cup center height was shown as the distance from tear drop, and cup medialization was shown as horizontal distance from inner wall of acetabulum. Leg elongation and offset change were navigated by comparing the two reference points in femur between registration before neck resection and that after inserting the trial implant. After operation, the cup angles were measured on CT image, and cup center position, leg elongation and offset change were measured on plain radiography. We compared these values that indicated by the navigation system to those measured on the CT image and the plain radiography. The average cup inclination was 37.5 ± 7.0 degree and anteversion was 22.2 ± 4.7 degree. The average absolute difference between navigation and measured angles were 5.2 ± 4.0 degree in inclination, 5.9 ± 4.0 degree in anteversion. The difference of cup height was 5.8 ± 3.9 mm, cup medialization was 3.8 ± 2.7 mm, leg elongation was 4.3±3.3mm, and offset was 5.4±4.1mm, respectively. By using this new version navigation system, we can plan the cup center position and navigate it within smaller error of vertical and horizontal direction than the previous system. Moreover, leg elongation and offset change can be satisfactory navigated during operation. However surgeon's skill and learning curve might have influence the accuracy. We have to continue to evaluate this system and make effort to further improvement.
Thirty four patients underwent 34 single entry percutaneous physiodesis (SEPP) of both distal femur and proximal tibia between July 1996 and June 2004. Twenty six patients had attained maturity and the rest continue to be followed up. There were 10 females and 16 males. The mean ages were12.8yrs (range11–14yrs) and 13.8yrs (range11–15) respectively. All patients underwent at least three assessments of limb length discrepancy(lld) using CT Scannograms. The Mosely’s straight line graph was then used to predict lld and timing of correction. The procedure was performed under image intensifier control using a 6.5mm drill passed through a small incision. The drill was passed in three directions through a single entry . The physis was curetted. The mean lld at SEPP was 3.36cm(range1.5–5.9cm). The prediction of lld at maturity after SEPP was a mean of 1.4cm(range0.2–2.5cm) and final lld was a mean of 1.38cm (range0.3–2.5cm). The accuracy of prediction was found to have a mean of 0.44cm (range0–0.7cm). One patient (6%) complained of knee pain for about 2 weeks that settled. The rest had no complications. We feel that this technique is minimally invasive with a cosmetic scar, has a shorter hospital stay, low complications and is reliable for phuseal ablation. This technique aided by the CT scannogram and a Mosely’s straight line graph provides a reliable and effective method in the management of small amounts of lld.
Aims. The primary aim of this study was to compare the hip-specific functional outcome of robotic assisted total hip arthroplasty (rTHA) with manual total hip arthroplasty (mTHA) in patients with osteoarthritis (OA). Secondary aims were to compare general health improvement, patient satisfaction, and radiological component position and restoration of
Hop tests are used to determine return to sports after ACL reconstruction. They mostly measure distance and symmetry but do not assess kinematics and kinetics. Recently, biomechanical evaluations have been incorporated into these functional jump tests for the better assessment of return to sport. We assessed the sagittal plane range of motion (ROM) of the knee, the deviation axis of rotation (DAOR), and the vertical ground reaction force (vGRF) normalized to body weight in nine healthy participants during the single leg (SLH) and crossover hop tests (COHT). Participants'
Introduction. Legg-Calvé-Perthes disease (LCPD) often results in femoral head deformity and leg length discrepancy (LLD). Objective of this study was to analyse femoral morphology in LCPD patients at skeletal maturity to assess where the LLD originates, and evaluate the effect of contralateral epiphysiodesis for length equalisation on proximal and subtrochanteric femoral lengths. Materials and Methods. All patients treated for LCPD in our institution between January 2013 and June 2020 were retrospectively reviewed. Patients with unilateral LCPD, LLD of ≥5mm and long leg standing radiographs at skeletal maturity were included. Total
Aims. Traditionally, acetabular component insertion during total hip arthroplasty (THA) is visually assisted in the posterior approach and fluoroscopically assisted in the anterior approach. The present study examined the accuracy of a new surgeon during anterior (NSA) and posterior (NSP) THA using robotic arm-assisted technology compared to two experienced surgeons using traditional methods. Methods. Prospectively collected data was reviewed for 120 patients at two institutions. Data were collected on the first 30 anterior approach and the first 30 posterior approach surgeries performed by a newly graduated arthroplasty surgeon (all using robotic arm-assisted technology) and was compared to standard THA by an experienced anterior (SSA) and posterior surgeon (SSP). Acetabular component inclination, version, and
Aims. This study aimed to investigate the incidence of ≥ 5 mm asymmetry in lower and whole
Purpose. Leg length discrepancy after total hip arthroplasty (THA) sometimes causes significant patient dissatisfaction. In consideration of the
Abstract. OBJECTIVES. Application of deep learning approaches to marker trajectories and ground reaction forces (mocap data), is often hampered by small datasets. Enlarging dataset size is possible using some simple numerical approaches, although these may not be suited to preserving the physiological relevance of mocap data. We propose augmenting mocap data using a deep learning architecture called “generative adversarial networks” (GANs). We demonstrate appropriate use of GANs can capture variations of walking patterns due to subject- and task-specific conditions (mass,
Introduction. Angular deformities of the distal femur can be corrected by opening, closing and neutral wedge techniques. Opening wedge (OW) and closing wedge (CW) are popular and well described in the literature. CW and OW techniques lead to
In recent years, there has been increasing interest in the use of simultaneous hip arthroplasty compared to staged procedures in patients with bilateral pathology. The aim of this study was to compare simultaneous and staged hip arthroplasty in patients with bilateral pathology by assessing the transfusion rate, postoperative hemoglobin drop, length of stay (LOS), in-hospital complications, 30-days readmissions,
Preoperative planning is a crucial step for total hip arthroplasty (THA), and 2D X-ray images are commonly used. The planning aims to provide the correct implant size, restore functional biomechanical conditions and avoid early complication such as dislocation, leg length discrepancy or abductors insufficiency. Limitations of 2D planning, besides the low accuracy in sizing, concerns the inability of planning the anteversion of both acetabular and femoral component on axial plane. Also, the verification of the planning intraoperatively is wholly left to qualitative measurements and the surgeon's experience. The need for having a more accurate and functional preoperative planning has been addressed using 3D models. The MyHip Planner (MHP) (Medacta International, Castel San Pietro, Switzerland), is a preoperative planning software which through artificial intelligent algorithm converts the CT scans into a 3D model that perfectly match the patient's anatomy. Then, automatic positioning of the implants is performed following the personal settings of the surgeon which will check and validate the planning, a personalized simulation of six daily activities to detect impingement of implants and bones. The MyHip Verifier (MHV) intraoperatively verifies the execution of the planning in terms of
Introduction. The most challenging aspect in rotational deformity correction is translating the pre-operative plan to an accurate intra-operative correction. Landmarks away from the osteotomy site are typically employed at pre-operative planning and this can render inadequate correction. Our proposed technique of pre-operative planning using CT scan and
Aims. Hip arthroplasty does not always restore normal anatomy. This is due to inaccurate surgery or lack of stem sizes. We evaluated the aptitude of four total hip arthroplasty systems to restore an anatomical and medialized hip rotation centre. Methods. Using 3D templating software in 49 CT scans of non-deformed femora, we virtually implanted: 1) small uncemented calcar-guided stems with two offset options (Optimys, Mathys), 2) uncemented straight stems with two offset options (Summit, DePuy Synthes), 3) cemented undersized stems (Exeter philosophy) with three offset options (CPT, ZimmerBiomet), and 4) cemented line-to-line stems (Kerboul philosophy) with proportional offsets (Centris, Mathys). We measured the distance between the templated and the anatomical and 5 mm medialized hip rotation centre. Results. Both rotation centres could be restored within 5 mm in 94% and 92% of cases, respectively. The cemented undersized stem performed best, combining freedom of stem positioning and a large offset range. The uncemented straight stem performed well because of its large and well-chosen offset range, and despite the need for cortical bone contact limiting stem positioning. The cemented line-to-line stem performed less well due to a small range of sizes and offsets. The uncemented calcar-guided stem performed worst, despite 24 sizes and a large and well-chosen offset range. This was attributed to the calcar curvature restricting the stem insertion depth along the femoral axis. Conclusion. In the majority of non-deformed femora,
We investigated whether a novel, real-time fluoroscopy based navigation system optimized component positioning and
Infected non-unions of proximal femoral fractures are difficult to treat. If debridement and revision fixation is unsuccessful, staged revision arthroplasty may be required. Non-viable tissue must be resected, coupled with the introduction of an antibiotic-eluting temporary spacer prior to definitive reconstruction. Definitive tissue microbiological diagnosis and targeted antibiotic therapy are required. In cases of significant proximal femoral bone loss, spacing options are limited. We present a case of a bisphosphonate-induced subtrochanteric fracture that progressed to infected non-union. Despite multiple washouts and two revision fixations, the infection remained active with an unfavourable antibiogram. The patient required staged revision arthroplasty including a proximal femoral resection. To enable better function by maintaining
Aims. There is little information in the literature about the use of dual-mobility (DM) bearings in preventing re-dislocation in revision total hip arthroplasty (THA). The aim of this study was to compare the use of DM bearings, standard bearings, and constrained liners in revision THA for recurrent dislocation, and to identify risk factors for re-dislocation. Methods. We reviewed 86 consecutive revision THAs performed for dislocation between August 2012 and July 2019. A total of 38 revisions (44.2%) involved a DM bearing, while 39 (45.3%) and nine (10.5%) involved a standard bearing and a constrained liner, respectively. Rates of re-dislocation, re-revision for dislocation, and overall re-revision were compared. Radiographs were assessed for the positioning of the acetabular component, the restoration of the centre of rotation,
Hip abductor deficiency (HAD) associated with hip arthroplasty can be a chronic, painful condition that can lead to abnormalities in gait and instability of the hip. HAD is often confused with trochanteric bursitis and patients are often delayed in diagnosis after protracted courses of therapy and steroid injection. A high index of suspicion is subsequently warranted. Risk factors for HAD include female gender, older age, and surgical approach. The Hardinge approach is most commonly associated with HAD because of failure of repair at the time of index surgery or subsequent late degenerative or traumatic rupture. Injury to the superior gluteal nerve at exposure can also result in HAD and is more commonly associated with anterolateral approaches. Multiple surgeries, chronic infection, and chronic inflammation from osteolysis or metal debris are also risk factors especially as they can result in bone stock deficiency and direct injury to muscle. Increased offset and/or
Restoring native hip anatomy and biomechanics is important to create a well-functioning total hip arthroplasty (THA). Hip offset and
Aims. Cement-in-cement revision of the femoral component represents a widely practised technique for a variety of indications in revision total hip arthroplasty. In this study, we compare the clinical and radiological outcomes of two polished tapered femoral components. Methods. From our prospectively collated database, we identified all patients undergoing cement-in-cement revision from January 2005 to January 2013 who had a minimum of two years' follow-up. All cases were performed by the senior author using either an Exeter short revision stem or the C-Stem AMT high offset No. 1 prosthesis. Patients were followed-up annually with clinical and radiological assessment. Results. A total of 97 patients matched the inclusion criteria (50 Exeter and 47 C-Stem AMT components). There were no significant differences between the patient demographic data in either group. Mean follow-up was 9.7 years. A significant improvement in Oxford Hip Score (OHS), Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC), and 12-item Short-Form Survey (SF-12) scores was observed in both cohorts.
Custom 3D printed implants can be anatomically designed to assist in complex surgery of the bony pelvis in both orthopaedic oncology and orthopaedic reconstruction surgery. This series includes patients who had major pelvic bone loss after initially presenting with tumours, fractures or infection after previous total hip arthroplasty. The extent of the bone loss in the pelvis was severe and therefore impossible to be reconstructed by conventional ‘off –the-shelve’ implants. The implant was designed considering the remaining bony structures of the contra-lateral hemi- pelvis, to provide an anatomical, secured support for the reconstructed hip joint. The latter was realised by strategically orientated screws and by porous structures (an integral part of the implant), which stimulates osseointegration. A custom pelvic implant was designed, manufactured and 3D printed. Reconstruction of the pelvis was performed together with a cemented (bipolar bearing) acetabular cup. In some cases, a proximal femoral replacement was also necessary to compensate for bony defects. All patients had sufficient range of motion (ROM) at the hip with post-operative stability. It has been verified, at six and twelve months postoperatively, that there is a strong hold of the implant due to osseointegration. Additionally, in patients whose posterior acetabular wall was missing, it was discovered that the implant assisted in bone formation and covered the entire posterior surface of the implant. All patients in this study managed with this novel treatment option, proved to have a stable pelvic reconstruction with restoration of
Introduction. Coronal malalignment and leg length discrepancies (LLD) are frequently associated. Temporary hemiepiphysiodesis (tHED) is commonly employed for the correction of limb malalignment in skeletally immature patients. For treatment of LLD greater than 2 cm, lengthening with intramedullary legnthening nails is a safe and reliable technique. However, the combined application of these approaches in skeletally immature patients has not yet been investigated. Materials & Methods. Retrospective radiological and clinical analysis of 25 patients (14 females, 11 males) who underwent intramedullary femoral lengthening with an antegrade PRECICE® lengthening nail as well as tHED of the distal femur and / or proximal tibia between 2014 and 2019. tHED was conducted by implantation of flexible staples (FlexTack™) either prior (n = 11), simultaneously (n = 10), or subsequently (n = 4) to femoral lengthening. The mean follow-up period was 3.7 years (±1.4). Results. The median initial LLD was 39.0 mm (35.0–45.0). 21 patients (84%) presented valgus and 4 (16%) showed varus malalignment.
Vacuum orthoses are being applied in the care of patients with foot and lower leg conditions, as ankle fractures or sprains. The lower leg is protected and immobilized, which increases mobility. Due to the design, the orthoses lead to a difference in
To investigate differences in the drop vertical jump height in female adolescents with an ACL injury and healthy controls and the contribution of each limb in this task.
Forty female adolescents with an ACL injury (ACLi, 15.2 ± 1.4 yrs, 164.6 ± 6.0 cm, 63.1 ± 10.0 kg) and thirty-nine uninjured (CON, 13.2 ± 1.7 yrs, 161.7 ± 8.0 cm, 50.6 ± 11.0 kg) were included in this study. A 10-camera infrared motion analysis system (Vicon, Nexus, Oxford, UK) tracked pelvis, thigh, shank, and foot kinematics at 200Hz, while the participants performed 3 trials of double-legged drop vertical jumps (DVJ) on two force plates (Bertec Corp., Columbus, USA) sampled at 2000Hz.The maximum jump height normalised by dominant
Dual-mobility (DM) bearings are effective to mitigate dislocation in revision total hip arthroplasty (THA). However, data on its use for treating dislocation is scarce. Aim of this study was to compare DM bearings, standard bearings and constrained liner (CL) in revision THA for recurrent dislocation and to identify risk factors for re-dislocation. We reviewed 100 consecutive revision THAs performed for dislocation from 2012 and 2019. 45 hips (45%) received a DM construct, while 44 hips (44%) and 11 hips (11%) had a standard bearing and CL, respectively. Rates of re-dislocation, re-revision for dislocation and overall re-revision were compared. Radiographs were assessed for cup positioning, restoration of centre of rotation,
To investigate if the countermovement jump height differs between ACL injured and uninjured female adolescents and to explore kinematic differences between limbs. Additionally, the association between isometric knee extension strength and jump height was investigated. Thirty-one ACL injured female adolescents (ACLi, 15.3 ± 1.4yrs, 163.9 ± 6.6cm, 63.0 ± 9.3kg) and thirty-eight uninjured (CON, 13.2±1.7yrs, 161.7 ± 8.1cm, 50.6 ± 11.1kg) participated in this study. All participants performed a countermovement jump task, with 3D kinematics collected using a motion analysis system (Vicon, Nexus, Oxford, UK) at 200Hz, and a maximum isometric knee extension task on an isokinetic dynamometer (Biodex Medical Systems, New York, USA) for three trials. The peak torque was extracted from the isometric trials. Independent samples t-test compared the maximum jump height normalised by the dominant
In the congenital hip dysplasia, patients treated with total hip replacement (THR) often report persistent disability and pain, with unsatisfactory function and quality of life. A major challenge is to restore the center of rotation of the hip and a satisfactory abduction function [1]. The position of the acetabular cup during THR might be crucial, as it affects abduction moment and motor function. Recently, several software systems have been developed for surgical planning of endoprostheses. Previously developed software called HipOp [2], which is routinely used in clinics, allows surgeons to properly position the prosthetic components into the 3D space of CT data. However, this software did not allow to simulate the articular range of motion and the condition of the abductor muscles. Our aim is to present HipOpCT, an advanced version of the software that includes 3D musculoskeletal planning, through the application to hip dysplasia patients to add knowledge in the diagnosis and treatment of such patients who need THR. 40 hip dysplasia patients received pre-operative CT scanning of pelvis and thighs and had their THR surgery planned using HipOpCT. The base planning includes import of CT data, positioning of prosthetic components interactively through multimodal display, as well as geometrical measurements of the implant and the host bone. The advanced planning additionally includes evaluation of femoro-acetabular impingement and calculation of
Introduction. When performing a total hip arthroplasty (THA), some surgeons routinely perform an intraoperative anteroposterior (AP) pelvis radiograph to assess components. The purpose of this study was to evaluate the reliability of the intraoperative radiograph to accurately reflect acetabular inclination,
Introduction. Aneurysmal bone cysts commonly found in lower limbs are locally aggressive masses that can lead to bony erosion, instability and fractures. This has major implications in the lower limbs especially in paediatric patients, with potential growth disturbance and deformity. In this case series we describe radical aneurysmal bone cyst resection and lower limb reconstruction using cable transport and syndesmosis preservation. Materials & Methods. Case 1 - A 12-year-old boy presented with a two-week history of atraumatic right ankle pain. An X-ray demonstrated a distal tibia metaphyseal cyst confirmed on biopsy as an aneurysmal bone cyst. The cyst expanded on interval X-rays from 5.5cm to 8.5cm in 9 weeks. A wide-margin en-bloc resection was performed leaving a 13.8cm tibial defect. A cable transport hexapod frame and a proximal tibial osteotomy was performed, with syndesmosis screw fixation. The transport phase lasted 11 months. While in frame, the boy sustained a distal femur fracture from a fall. The femur and the docking site were plated at the same sitting and frame removed. At one-year post-frame removal he is pain-free, with full ankle dorsiflexion but plantarflexion limited to 25 degrees. He has begun graduated return to sport. Results. Case 2 - A 12-year-old girl was referred with a three-month history of lateral left ankle swelling. X-ray demonstrated an aneurysmal bone cyst in the distal fibula metaphysis. The cyst grew from 4.2 × 2.3cm to 5.2 × 3.32cm in 2 months. A distal fibula resection (6.2cm) with syndesmosis fixation and hexapod cable transport frame were undertaken. The frame was in situ for 13 weeks and during this time she required an additional osteotomy for premature consolidation and had one pin site infection. After 13 weeks a second syndesmosis screw was placed, frame removed, and a cast applied. 3 months later she had fibular plating, BMAC and autologous iliac crest bone graft for slow union. At 3 years post-operative she has no evidence of recurrence, is pain-free and has no functional limitation. Conclusions. We describe two cases of ankle syndesmosis preservation using cable transport for juxta-articular aneurysmal bone cysts. This allows wide resection to prevent recurrence while also preserving primary ankle stability and
Restoration of anatomy is paramount in total hip arthroplasty (THA) to optimise function and stability. Leg-length discrepancy of ≥10mm is poorly tolerated and can be the subject of litigation. We routinely use a multimodal protocol to optimise soft tissue balancing which involves pre-operative templating, leg-length measurement supine and in the lateral position after positioning, and the use of an intra-operative leg-length measurement device to ensure optimisation of leg-length. We have analysed the results of our protocol in restoring leg-length in primary THA. Radiological leg-length was measured in a consecutive series of 50 patients who had THA for unilateral arthritis by an independent observer pre- and post-operatively using validated methods utilising radiological software. The measurements pre- and post-operative were compared. Patients with bilateral hip arthritis and poor imaging were excluded. Leg-length was successfully restored to within 5.0mm of the target leg-length in 84.0% of patients (mean +0.7mm (95% CI +0.2 to +1.1)). The other 14.0% of patients were restored to within 5.1–8.0mm (mean +2.2mm (95% CI −2.7 to +7.1)) and 2.0% of patients were restored to within 8.1–10.0mm.
Introduction. Correct postoperative
Aims. Iliopsoas pathology is a relatively uncommon cause of pain following total hip arthroplasty (THA), typically presenting with symptoms of groin pain on active flexion and/or extension of the hip. A variety of conservative and surgical treatment options have been reported. In this retrospective cohort study, we report the incidence of iliopsoas pathology and treatment outcomes. Methods. A retrospective review of 1,000 patients who underwent THA over a five-year period was conducted, to determine the incidence of patients diagnosed with iliopsoas pathology. Outcome following non-surgical and surgical management was assessed. Results. In all, 24 patients were diagnosed as having developed symptomatic iliopsoas pathology giving an incidence of 2.4%. While the mean age for receiving a THA was 65 years, the mean age for developing iliopsoas pathology was 54 years (28 to 67). Younger patients and those receiving THA for conditions other than primary osteoarthritis were at a higher risk of developing this complication. Ultrasound-guided steroid injection/physiotherapy resulted in complete resolution of symptoms in 61% of cases, partial resolution in 13%, and no benefit in 26%. Eight out of 24 patients (who initially responded to injection) subsequently underwent surgical intervention including tenotomy (n = 7) and revision of the acetabular component (n = 1). Conclusion. This is the largest case series to estimate the incidence of iliopsoas pathology to date. There is a higher incidence of this condition in younger patients, possibly due to the differing surgical indications. Arthoplasty for Perthes' disease or developmental dysplasia of the hip (DDH) often results in
The MAKO Robotic arm is a haptic robotic system that can be used to optimise performance during total hip arthroplasty (THA). We present the outcome of the first 40 robotic cases performed in an NHS foundation trust along with the technique of performing robotic THA in our unit. Forty consecutive patients undergoing robotic THA (rTHA) were compared to a case matched group of patients undergoing manual THA (m-THA). 2:1 blinded case matching was performed for age, sex, implants used (Trident uncemented socket and cemented Exeter stem, Stryker Mahwah, NJ, US) and surgeon grade. Comparisons were made for radiological positioning of implants, including
INTRODUCTION. Combining novel diverse population-based software with a clinically-demonstrated implant design is redefining total hip arthroplasty. This contemporary stem design utilized a large patient database of high-resolution CT bone scans in order to determine the appropriate femoral head centers and neck lengths to assist in the recreation of natural head offset, designed to restore biomechanics. There are limited studies evaluating how radiographic software utilizing reference template bone can reconstruct patient composition in a model. The purpose of this study was to examine whether the application of a modern analytics system utilizing 3D modeling technology in the development of a primary stem was successful in restoring patient biomechanics, specifically with regards to femoral offset (FO) and leg length discrepancy (LLD). METHODS. Two hundred fifty six patients in a non-randomized, post-market multicenter study across 7 sites received a primary cementless fit and fill stem. Full anteroposterior pelvis and Lauenstein cross-table lateral x-rays were collected preoperatively and at 6-weeks postoperative. Radiographic parameters including contralateral and operative FO and LLD were measured. Preoperative and postoperative FO and LLD of the operative hip were compared to the normal, native hip. Clinical outcomes including the Harris Hip Score (HHS), Lower Extremity Activity Scale (LEAS), Short Form 12 (SF12), and EuroQol 5D Score (EQ-5D) were collected preoperatively, 6 weeks postoperatively, and at 1 year. RESULTS. The mean age is 62 years old (range 32 – 75), 136 male and 120 female, BMI 29.7. The preoperative FO and LLD of the operative hip were 43.5 mm (±9.0 mm) and 3.0 mm (±6.5 mm) compared to the native contralateral hip, respectively. The postoperative FO and LLD were 46.4 mm (±8.7 mm) and 1.6 mm (±7.6 mm) compared to the native contralateral hip, respectively. The change in FO on the operative side was 3.0 mm (±7.2 mm) (p<0.0001) and the change in LLD from preoperative to 6-weeks postoperative was 1.6 mm (±8.4 mm) (p=0.0052) (Figure 1), demonstrating the ability of this stem design to recreate normal hip biomechanics in this study. The HHS increased considerably from a preoperative score of 55.9 to 78.4 at 6 weeks and 92.7 at 1 year. Clinically significant improvements were also seen at 1 year in the LEAS (+2.3), SF12 PCS (+16.3), and EQ-5D TTO (+0.26) and the EQ-5D VAS (+15.7). DISCUSSION and CONCLUSION. This study demonstrated that recreation of normal anatomic
Acetabular cup positioning remains a real challenge and component malpositioning after total hip arthroplasty (THA) can lead to increased rates of dislocation and wear. It is a common cause for revision THA. A novel 3D imageless mini-optical navigation system was used during THA to provide accurate, intraoperative, real-time, and non-fluoroscopic data including component positioning to the surgeon. This retrospective comparative single surgeon and single approach study examined acetabular component positioning between traditional mini-posterolateral THA and mini-posterolateral THA using the 3D mini-optical navigation system. A retrospective chart review was conducted of 157 consecutive (78 3D mini-optical navigation and 79 traditional non-navigation methods) THAs performed by the senior author using a mini-posterolateral approach at an ambulatory surgery center and hospital setting. Two independent reviewers analyzed postoperative radiographs in a standardized fashion to measure acetabular component positioning. Demographic, clinical, surgical, and radiographic data were analyzed. These groups were found to have no statistical difference in age, gender, and BMI (Table I). There was no difference between groups in acetabular components in the Lewinnek safe zone, 31.2% vs 26.6% (p = 0.53). Cup anteversion within the safe zone did not differ, 35.1% vs 40.5% (p = 0.48); while cup inclination within the safe zone differed, with more in the navigation group, 77.9% vs 51.9% (p < 0.01). Change in
Purpose: Clinical studies still show significant variability in offset and
In schoolchildren screened for scoliosis about 40% have minor, non-progressive, lumbar scolioses secondary to pelvic tilt with leg-length and/or sacral inequality [1] not reported with preoperative thoracic curves [2]. Forty-nine of 108 consecutive adolescent patients referred from routine scoliosis school screening during 1996–1999 had lower spinal scoliosis with measurable radiological sacral alar and hip tilt angles – lumbar scoliosis 18, thoracolumbar scoliosis 31 (girls 41, boys 8, mean Cobb angle 16 degrees, range 4–38 degrees). In standing full spine antero-posterior radiographs measurements were made of Cobb angle and pelvic asymmetries as sacral alar and iliac heights (left minus right). From anthropometric measurements derivatives were calculated as ilio-femoral
Background. Exeter Trauma Stem (ETS) is a polished tapered collarless monopolar prosthesis used for cemented hemiarthroplasty for fracture neck of femur. Two modular rasps are available on the instrumentation set. The larger rasp, in practice, rarely fits into the femur making trial reduction impossible. Our hypothesis was that the absence of a trial reduction could affect
Background. It is unclear which form of anaesthesia is the most favourable in primary total hip replacement (THR) surgery. A recently published systematic review of modern anaesthesia techniques in primary THR surgery (Macfarlane 2009) was not able to show any convincing benefit of regional or general anaesthesia. One retrospective study that examined anaesthesia and
Introduction:. Paley et al has developed a multiplier method for calculating both
Cement-in-cement revision of the femoral component represents a widely practiced technique for a variety of indications. In this study we compare the clinical and radiological outcomes of two polished tapered stems. From our prospectively collated database we identified all patients undergoing cement-in-cement revision from January 2005 – 2013 who had a minimum of two years follow-up. All cases were performed by the senior author using either an Exeter short revision stem or the C-stem AMT high offset No 1. Patients were followed-up annually with clinical and radiological assessment. Ninety-seven patients matched the inclusion criteria. There were 50 Exeter and 47 C-stem AMT components. There were no significant differences between the patient demographics in either group. Mean follow-up was 9.7 years. A significant improvement in OHS, WOMAC and SF-12 scores was observed in both cohorts.
Background:. Paley et al has developed the multiplier method for predicting
Introduction. The primary purpose of Total Hip Arthroplasty (THA), aside from pain relief, is to restore hip biomechanics such that the patient experiences no discernible functional deficit, while also providing an environment conducive to implant longevity. Key factors in determining a successful THA include achieving the desired pre-operative femoral offset and
Background:. Acetabular cup positioning. 1, 2. , leg length discrepancy. 3. and global offset. 4. are important parameters associated with outcomes following total hip arthroplasty (THA). Deviation from an accepted range of values for each of these parameters can lead to significant complications including nerve injury, low back pain, abnormal gait, increased dislocation rate, and bearing surface wear. The primary purpose of this study was to assess whether the use of the MAKO™ robotic hip system is reliable in predicting post-operative radiographic measurements of cup inclination, cup anteversion,
Introduction. Acetabular component positioning, offset, combined anteversion,
Introduction. Computer navigation is a highly sophisticated tool in orthopedic surgery for component placement in total hip arthroplasty (THA). A number of recommendations have been published. Although Lewinnek's safe-zone is the best-known among these its significance is questioned in recent years since it addresses the acetabular socket only ignoring the femoral stem. Modern target definitions consider both socket and stem and provide well-defined recommendations for complementary component positioning. We present a new small-sized hand-held imageless navigation system that implies these targets and supports the surgeon in realizing the concept of combined anteversion and combined Target-Zone (cTarget- Zone) in THA and to control
Predictions of lower limb growth are based upon historical data, collected from patients who had coexistent poliomyelitis. By utilising standardised longitudinal prospective European data, our objective was to generate superior estimates for the age and rate at which lower limb skeletal maturity is reached; thus improving the timing of epiphysiodesis, for the management of leg length discrepancy. The Avon Longitudinal Study of Parents and Children of the 90s (ALSPAC) is a longitudinal cohort study of children recruited antenatally 2. Using a previously validated Multiplier Method, a sequence of
Aims. Accurate placement of acetabular and femoral stem components in total hip arthroplasty (THA) is an important factor in the success of the procedure. A variety of free hand or navigated techniques is reported. Survivorship and complications have been shown to be directly related to implant position during THA. The aim of this cadaver study was to assess the accuracy of the placement of the components in THA using patient specific instruments (PSI) in combination with a 3D planning software and the direct anterior approach. Method. Patient specific instruments (PSI) were developed to guide the surgeon during THA that were 3D printed with their bone models following a 3D software planning protocol (LPH software V2.5.1, Onefit-Medical, Eos Imaging Company, Besancon, France). Acetabular guides: cup, offset and straight reamer handle and impactor, femoral- and chisel guides were used in each THA (Fig. 1). To define anatomic bone landmarks and to generate a 3D model of each hip joint CT scans were performed preoperatively. The planning of component position was done by one surgeon (AZ) preop. Surgery was performed by two experienced surgeons (AZ, SD) on cadaver specimen with 4 hips in two separate series. A total of 8 hip replacements were evaluated pre- and postoperatively using CT-scans of each hip joint to compare planned to achieved results. Mechanical simulations of the guides were carried out to verify that there were no conflicts between the different instruments. To meet the ISO standard 16061: 2015 the compatibility of the instruments with the guides has been checked. Parameters were evaluated in 3D pelvic and femoral planes: center cup position, inclination angle, anteversion angle, cutting height and plan orientation, anteversion angle, flexion/extension angle, varus/valgus angle, anatomical and functional
Abstract. Objectives. 1. To investigate the effect of revision total knee replacement (TKR) on gait kinematics in patients with a primary TKR and instability.2. To compare gait kinematics between patients with a well-functioning TKR and those with a primary TKR and symptoms of instability. Methods. This single-centre observational study is following patients who have had a revision TKR due to knee instability. Data was collected pre- and post-operatively at 8–12 week follow-up. The data was compared to a control group of 18 well-functioning TKR patients. Kinematic gait data was collected during routine clinics using a treadmill-based infrared 3D system (Vicon, Oxford, UK) and a published lower limb marker-set. Patients performed 15 strides at three different speeds: 0.6mph, self-selected, and a ‘slow walk’ normalised to
Acetabular component positioning is highly correlated with total hip arthroplasty (THA) outcomes. Multiple reports however indicate that less than 50% of acetabular cups are placed within surgeon-desired ranges for abduction and anteversion angles when using conventional cup positioning techniques. Issues with improper placement include instability-dislocation, impingement and impact on range of motion, polyethylene wear, leg length discrepancy, and gait mechanics. Accuracy in placement of the acetabular component is complicated by the need to estimate cup impactor angles to create desired cup position. A low cost approach to THA using Image-based Ultrasonic Guidance (IUG) (Orthosensor, Sunrise, FL) coupled to existing surgical tools is presented. IUG utilises acoustic measurement techniques for achieving optimal component positioning and
Aims.
Introduction: Patients following resurfacing frequently remark about the natural feel of the resurfaced hip joint in contrast to those with total hip arthroplasty. Possible reasons for this include the larger femoral head size, conservation of bone and superior biomechanics of the implant with more accurate restoration of femoral offset,
Total hip replacement for high dislocation of the hip joint remains technically difficult in terms of preparation of the true acetabulum and restoration of
Introduction & aims. Correct prosthetic alignment is important to the longevity and function of a total hip replacement (THR). With the growth of 3-dimensional imaging for planning and assessment of THR, the importance of restoring, not just
While squeaking ceramic bearings in total hip arthroplasty are increasingly reported in the literature, the etiology remains unclear. Cup inclination and anteversion have been correlated with the phenomenon but even amongst well positioned cups bearing noise is observed. Most studies do not distinguish between different types of noise or incidence rate and do only investigate actively complaining patients. This study analysed the incidence of ceramic bearing noise in a single type of hip implant and investigates correlations with patient, implant and surgery parameters. In a consecutive series of 145 ceramic-on-ceramic primary hips (Stryker ABG-II, 28mm head) in 132 patients (m/f=72/60, avg. age=54yrs) and an average follow-up of 3.0 (1–7) years, noisy bearings were identified by a patient questionnaires stating the type of noise (squeaking, clicking, scratching, combinations), time of initial incidence, incidence rate (permanent, often, sometimes, rare) and type of movement. Patient demographics (age, gender, height, weight, BMI, side of surgery,
We compared a modular neck system with a non-modular system in a cementless anatomical total hip replacement (THR). Each group consisted of 74 hips with developmental hip dysplasia. Both groups had the same cementless acetabular component and the same articulation, which consisted of a conventional polyethylene liner and a 28 mm alumina head. The mean follow-up was 14.5 years (13 to 15), at which point there were significant differences in the mean total Harris hip score (modular/non-modular: 98.6 (64 to 100)/93.8 (68 to 100)), the mean range of abduction (32° (15° to 40°)/28 (0° to 40°)), use of a 10° elevated liner (31%/100%), the incidence of osteolysis (27%/79.7%) and the incidence of equal
Introduction. Our primary hypothesis was simple: does gait on a downhill gradient distinguish between types of knee arthroplasty? Our secondary hypotheses were these: are stride length and other kinematic variables affected by cruciate ligament integrity following knee arthroplasty?. Participants. Ethical approval was sought and gained prior to commencement of the study. 52 subjects were tested on the instrumented treadmill, 3 groups (UKA, TKA, and young healthy control) of 19, 14, and 19 respectively. The two high performing arthroplasty groups were recruited from a database of patient related outcome measures (PROMs) and were chosen based on high Oxford knee scores (OKS) with a minimum 12 months post hip arthroplasty. Gait Analysis. Gait performance was tested on a validated instrumented treadmill (Kistler Gaitway®, Kistler Instrument Corporation, Amherst NY)[22, 23]. The rear of the treadmill was ramped with 30 cm axle stands in order to create a 7 degree decline for downhill walking (figure 1). The speed was increased incrementally. Hof scaling and body weight normalising was also applied to the outputted mechanical data to correct for
The position of the gastrocnemius tendon relative to the calcaneus and fibular head distance may be different in children with cerebral palsy (CP) when compared to normal children. However, no such data is available. Usually, palpation of the muscle bellies or previous experience of the operating surgeon is employed to place the surgical incision. Inaccurate localisation may cause incorrect incision and a risk of iatrogenic damage to the vital structures (i.e. sural nerve). The aim of our study is to compare gastrocnemius muscle length in-vivo between paretic and unaffected children and suggest a formula to localise muscle-tendon junction. Ten children with di/hemiplegia (seven females and three males; mean age 8y 7mo, range 2–14y) were recruited. None of them had received any conventional medical treatment. An equal number of age/sex matched, typically developing children (mean age 9y 1mo, range 4–14y) were recruited. Participants lay prone on an examination plinth with their feet hanging from its edge. Sagittal-plane ultrasound scanning of the gastrocnemius muscle at rest was performed to measure the length of gastrocnemius bellies. We also measured the heights, lower
Total hip joint replacement (THJR) for high riding congenital hip dislocation (CDH) is often performed in young patients, and presents unique problems with acetabular cup placement and