EFFECT OF A LEG LENGTH-EVENING DEVICE ON GAIT NORMALITY WHILE WEARING VACUUM ORTHOSES

The International Combined Orthopaedic Research Societies (ICORS), World Congress of Orthopaedic Research, Edinburgh, Scotland, 7–9 September 2022. Part 2 of 3.



Abstract

Vacuum orthoses are being applied in the care of patients with foot and lower leg conditions, as ankle fractures or sprains. The lower leg is protected and immobilized, which increases mobility. Due to the design, the orthoses lead to a difference in leg length, i.e. the side with the orthosis becomes longer, which changes the gait kinematics. To prevent or mitigate the unfavourable effects of altered gait kinematics, leg length-evening devices (shoe lifts) are offered that are worn under the shoe on the healthy side. Our aim was to evaluate the effect of such a device on the normality of gait kinematics.

Gait analysis was conducted with 63 adult, healthy volunteers having signed an informed consent form that were asked to walk on a treadmill at a speed of 4.5km/h in three different conditions:

  • barefoot - as reference for establishing the normality score baseline

  • with a vacuum orthosis (VACOPed, OPED GmbH, Germany) and a sport shoe

  • with a vacuum orthosis and a shoe lift (EVENup, OPED GmbH, Germany)

Data was sampled using the gait analysis system MCU 200 (LaiTronic GmbH, Austria). The positions of the joint markers were exported from the software and evaluated for the joint angles during the gait cycle using custom software (implemented in DIAdem 2017, National Instruments).

A normality score using a modification of the Gait Profile Score (GPS) was calculated in every 1%-interval of the gait cycle and evaluated with a Wilcoxon signed rank test.

The GPS value was reduced by 0.33° (0.66°) (median and IQR) while wearing the shoe lift. The effect was statistically significant, and very large (W = 1535.00, p < .001; r (rank biserial) = 0.52, 95% CI [0.29, 0.70]).

The significant reduction of the GPS value indicates a more normal gait kinematics while using the leg length-evening device on the contralateral shoe. This rather simple and inexpensive device thus might improve patient comfort and balance while using the vacuum orthoses.