The royal victoria hospital is a tertiary trauma centre receiving pelvic injury referrals for a population of 1.7 million. The use of ilio-sacral screw fixation with low anterior frame stabilisation has been adopted as the principle treatment for unstable pelvic ring injuries in our institution. We aim to describe our practice and outcomes following the use of percutaneous screw fixation of the pelvis. The review included standardised assessment of health-related quality of life (SF-36) as well as the Iowa pelvic score and Majeed pelvic injury outcome scores. Data was also collected on associated injuries, post-operative complications, nerve injury and pain scores. A total case series of 45 patients undergoing percutaneous ilio-sacral screw fixation following traumatic pelvic injury were identified over a 5 year period. Of these 23 were contactable to follow-up or responded to questionnaire review. The mean follow up was 680 days (range 151–1962). The mean age was 33 (range 18–57). The mean SF-36 physical and mental scores were 38 and 46 respectively. The mean Majeed score was 69 and Iowa pelvic score was 65. The mean pain score was 3.5 (range 0–7). There were no incidences of deep infection, post-operative PE or nerve injury related to screw insertion. Patients with isolated pelvic injuries performed better on outcome scoring however the low SF-36 scores highlight the severity of pelvic injuries
Stem geometry is known to influence the outcome in THA; however it is unknown whether the material properties, stiffness in particular can influence the stem stability and outcome. The aim of this study was to measure the influence of stem material properties on micromotion and migration using Roentgen Stereophotogrammetric Analysis (RSA) system. 41 patients were implanted with a collarless polished tapered (CPT) femoral stem (Zimmer, Warsaw, Indiana), which was made of either cobalt-chromium (CoCr) (n=21) or stainless steel (n=20). RSA was used to measure dynamically inducible micromotion (DIMM: difference in stem position in going from double-leg stance (DLS) to single leg stance (SLS)), prosthesis bending (difference in the head-tip distance when going from DLS to SLS), and mean migration of the head, tip and the cement restrictor. DIMM and bending were measured at 3 months, migration at 6, 12 and 24 months. All analyses were carried out using SPSS for windows (v.15.0.0, Chicago. IL, USA). Results were reported as mean ± 95% confidence interval (CI) and regarded as significant when p < 0.05.Introduction
Methods
Replacing bone lost as a consequence of trauma or disease is a major challenge in the treatment of musculoskeletal disorders. Tissue engineering strategies seek to harness the potential of stem cells to regenerate lost or damaged tissue. Bone marrow aspirate (BMA) provides a promising autologous source of skeletal stem cells (SSCs) however, previous studies have demonstrated that the concentration of SSCs required for robust tissue regeneration is below levels present in iliac crest BMA, emphasising the need for cell enrichment strategies prior to clinical application. To develop a novel strategy to enrich skeletal stem cells (SSCs) from human BMA, clinically applicable for intra-operative orthopaedic use.Background
Aims
This study was undertaken to evaluate the early results of a new implant system - the metaphyseal sleeve - in revision total knee replacement. The femoral and tibial metaphyseal sleeves are a modular option designed to deal with metaphyseal bone loss and achieve cementless fixation over a relatively wide area in the metaphysis. Over three years, femoral and/or tibial metaphyseal sleeves were implanted in 104 knees in 103 patients (54 male and 49 female). The clinical notes and radiographs of these patients were reviewed retrospectively. Thirty one patients had revision for infection, 42 for aseptic loosening, and 31 for instability, pain or stiffness. Eighty nine knees were revised as a single stage and 15 were done as two stage procedure. Minimum follow up is 12 months (average 18.5 months).Introduction
Methods
Skeletal stem cells (SSCs) have been used for the treatment of osteonecrosis of the femoral head to prevent subsequent collapse. In isolation SSCs do not provide structural support but an innovative case series in Southampton, UK, has used SSCs in combination with impaction bone grafting (IBG) to improve both the biological and mechanical environment and to regenerate new bone at the necrotic site. Analysis of retrieved tissue-engineered bone as part of ongoing follow-up of this translational case series.Background
Aims
Since the introduction of 3rd generation Metal-on-Metal-Hip-Resurfacing-Arthroplasty (MoMHRA), thousands of such prostheses have been implanted worldwide in younger patients with end-stage hip osteoarthritis. However, no independent centre has reported their medium-to-long term outcome. The aim of this study is to report the ten year survival and outcome of the Birmingham Hip Resurfacing (BHR), the most commonly used MoMHRA worldwide. Since 1999, 648 BHRs were implanted in 555 patients, the majority of which were male (326). The mean age at surgery was 52.1years (range: 17–82), with primary OA as most common indication (85%). Mean follow up was 7.1years (range: 1–11). The Oxford Hip Score (OHS) and UCLA questionnaires were sent to all patients. Implant survival was established, with revision as the end point. Sub-analysis was performed by gender, femoral component size (small: <45mm, standard: 46–52, large: >53mm) and age at surgery (young:<50yrs, old:>50yrs).Introduction
Methods
Despite interest, the current rate of day-case anterior cruciate ligament reconstruction (ACLR) in the UK remains low. Although specialised care pathways with standard operating procedures (SOPs) have been effective in reducing length of stay following some surgical procedures, this has not been previously reported for ACLR. We evaluate the effectiveness of SOPs for establishing day-case ACLR in a specialist unit. Fifty patients undergoing ACLR between May and September 2010 were studied prospectively (“study group”). SOPs were designed for pre-operative assessment, anaesthesia, surgical procedure, mobilisation and discharge. We evaluated length of stay, readmission rates, patient satisfaction and compliance to SOPs. A retrospective analysis of 50 patients who underwent ACLR prior to implementation of the day-case pathway was performed (“standard practice group”).Background
Methods
Total knee arthroplasty is an established and successful operation. In up to 10% of patients who undergo total knee arthroplasty continue to complain of pain [1]. Recently computerised tomography (CT) has been used to assess the rotational profile of both the tibial and femoral components in painful total knee arthroplasty. We reviewed 56 painful total knee replacements and compared these to 59 pain free total knee replacements. Datum gathered from case notes and radiographs using a prospective orthopaedic database to identify patients. The age, sex, preoperative Oxford score and BMI, postoperative Oxford score and treatments recorded. The CT information recorded was limb alignment, tibial component rotation, femoral component rotation and combined rotation.Introduction
Methods
In Europe, injectable collagenase clostridium histolyticum (CCH) is a novel, minimally invasive, non-surgical therapy with efficacy in correcting Dupuytren's contracture (DC). We evaluated the efficacy and tolerability of 5 CCH injections using a protocol designed to follow clinical practice. This was a 20-center, 9-month, open-label study in which DC patients with primary flexion deformities 20° (100° for MP; 80° for PIP) received 3 CCH (0.58 mg) injections/joint (5 injections/patient) at 30-day intervals. The primary endpoint was clinical success, defined as a reduction in contracture to 5° 30 days after the last injection (“Day 30”). After first injection into a prioritized joint, patients opted to receive up to 2 more injections into the same cord or cords from other affected joints whether or not they achieved clinical success with the first joint. Adverse events (AEs) were monitored.Introduction
Methods
Medial We prospectively evaluated 12 patients undergoing flatfoot reconstruction. Each patient had a preoperative AOFAS hindfoot score, pedobariographs and antero-posterior and lateral radiographs. This was repeated 6 months following surgery.Introduction
Materials and Methods
ARMD (Adverse Reaction to Metal Debris) is an increasingly recognised complication of metal on metal hip replacements. The MHRA (Medical and Healthcare Related Devices Agency) have advised a blood cobalt or chromium level above 7 mg/L is a threshold for further investigation, stating that “low levels are reassuring and strongly predict not having an adverse outcome”. Cross-sectional imaging should be performed when levels are above 7 mg/L. We have performed a study investigating the specificity and sensitivity of chromium and cobalt metal ion levels as a screening measure for ARMD. 79 ASR hip replacements were performed at our hospital and 75 (95%) of these underwent a Metal Artefact Reduction Sequence (MARS) MRI scan. All patients (64 hips) who had not undergone revision were invited to take part in this study. 57 patients with 62 hip replacements completed hip and activity scores, had blood cobalt and chromium ion level measurements and 3D-CT to measure acetabular component position. Acetabular component inclination (>50 degrees), small head size (< 51mm) and female gender were significantly correlated with raised chromium (Cr) and cobalt (Co) ion levels. An ARMD was detected using MRI in 18 (29%) of the hips in this study. The incidence of ARMD was significantly higher when chromium concentration was above 7 mg/l (p = 0.02). Chromium ion levels >7 mg/L had a sensitivity of 56% and specificity of 83% for ARMD, and cobalt ion levels >7 mg/L 56% and 76% respectively. 40 patients had cobalt levels <7 mg/L and 33 had chromium levels <7 mg/L, but 8 of these had an ARMD on MRI. All 8 patients had minimal symptoms (Oxford Hip Score ≥ 44 out of 48). The Medicines and Healthcare Products Regulatory Agency (MHRA) has recommended that cobalt and chromium levels be measured in patients with a metal-on-metal hip replacement and cross-sectional imaging performed when these levels are above 7 μg/L. This study has shown that by using this threshold, in patients with this implant combination, the sensitivity and specificity for the detection of ARMD is low and patients with soft tissue disease may be missed. Furthermore the presence of MRI detected ARMD, in the absence of significant clinical symptoms and with metal ion levels <7 μg/L is of concern. MoM implants at risk of failure are associated with raised cobalt and chromium levels. However metal ion analysis alone is not reliable as a screening tool for ARMD, which is often clinically “silent”. We recommend the routine use of MARS MRI as the safest method of ARMD diagnosis in patients with MoM implants.
The superficial anterior vasculature of the knee is variably described; most of our information comes from anatomical literature. Descriptions commonly emphasise medial-dominant genicular branches of the popliteal artery. Quantifying the relative contribution of medial and lateral vessels to the anastomotic network of the anterior knee may help provide grounds for selecting one of a number of popular incisions for arthrotomy. To describe the relative contribution of vessels to anastomoses supplying the anterior knee.Introduction
Aim
We describe the results for the management of chronic osteomyelitis in long bones using a new single stage procedure, the Cardiff technique. Fourteen consecutive patients were treated prospectively. The patients had a mean age of 52; all patients had a mean stay in hospital of 5 days with outpatient dressings. All patients had tibial fractures, 2 were infected non unions. The origin of infection was traumatic in 13 cases and haematogenous in 1 case. This one stage procedure or The Cardiff technique, uses techniques described by both Papineau's 3 stage method and Lautenbach's procedure. It involves removal of all avascular and infected tissue via marginal debridement, opening of the medullary cavity proximally and distally, compartmental debridement and copious saline irrigation. The wound is then packed with Jelonet and kaltostat and fresh dressings applied weekly. The wound is left to heal via secondary intention. There is no routine use of antibiotics. Antibiotics were only used when required, i.e. Clinical evidence of cellulitis or infection. 11 patients healed with no further surgery, no skin grafting, no bone grafting and no flap coverage. Mean time to healing was 5 months; both non unions united giving results similar to other accepted techniques. There were 3 residual infections, 2 due to inadequate debridement which required a single further compartmental debridement (Lautenbach method), 1 had an avascular bone edge requiring further local debridement. We feel this procedure confers the following advantages; minimal surgical insult, early discharge, out patient management, good outcomes and most importantly, high patient satisfaction. It also serves as a reminder that simple wounds do well with simple solutions.
Data was collected on 139 eligible patients a minimum of 18 months post surgery who had had 2 or more ligaments reconstructed. 63 patients were available for clinical follow up. It is the largest single surgeon series studied. 27% of injuries were high energy traffic accidents. 73% were low energy, mainly sports related. 63% of patients were delayed referrals to our unit. Of these nearly 48% had already undergone knee surgery, often more than 6 months post injury. 17% of all cases presented with failed ligament reconstructions. Of those patients followed up 19% were operated upon within 3 weeks of injury, 56% were delayed reconstructions with a mean time to surgery of 21 months and 25% were revision reconstructions. Time to follow up ranged from 18 months to 10 years. The median KOS ADL, KOS Sports Activity and Lysholm scores for uni-cruciate surgery were all better than those for bi-cruciate surgery. All results were better for acute rather than chronic cases, which in turn were better than those for revision cases. The Tegner score showed that only acute uni-cruciate reconstructions returned to their pre-injury level. TELOS stress radiographs demonstrated a mean post drawer of 5.9 mm side-to-side difference after reconstructions involving the PCL. IKDC grades showed 6% of knees were normal and 57% were nearly normal. 37% required further surgery, mainly to increase movement or for hardware removal. There was 1 deep infection and 2 cases of thrombosis. There were no vascular complications but 2 had transient nerve injuries. Multi-ligament surgery can produce good functional outcomes but the knee is never normal. There is an increased risk of PCL laxity post op. Early referral to a specialist unit is suggested as delayed referral to a specialist unit potentially subjects the patient to unnecessary surgery and may affect outcome.
Although chondrocytes have been used for autologous implantation in defects of articular cartilage, limited availability and donor-site morbidity have led to the search for alternative cell sources. Mesenchymal stem cells from various sources represent one option. The infrapatellar fat-pad is a promising source. Advantages include low morbidity, ease of harvest and ex-vivo evidence of chondrogenesis. Expansion of MSCs from human fat-pad in FGF-2 has been shown to enhance chondrogenesis. To further elucidate this process, we assessed the role of TGF-?3, FGF-2 and oxygen tension on growth kinetics of these cells during expansion. Infrapatellar fatpads were obtained from 4 donors with osteoarthritis. Cells were expanded in various media formulations (STD, FGF, TGF and FGF/TGF) at both 20% and 5% oxygen tensions. Colony forming unit fibroblast assays were performed for each expansion group and assessed with crystal violet staining. Cell aggregates from each group underwent chondrogenic differentiation in 5% and atmospheric oxygen tension. Pellets were analyzed on day 21. 5% Oxygen tension during expansion increased the colony size for both FGF and FGF/TGF groups. Cells expanded in FGF/TGF proliferated more rapidly. Biochemical analysis revealed that cells expanded in FGF-2 had higher glycosaminoglycan synthesis rates, a marker for chondrogenesis. Differentiation at 5% pO2 led to higher levels of sGAG but its effect was generally less potent compared to expansion in FGF-2.Methods
Results
The presence of a Hill-Sachs lesion is a major contributor to failure of surgical intervention following anterior shoulder dislocation. The relationship between lesion size, measured on pre-operative MRI, and risk of recurrent instability after surgery has not previously been defined. Hypothesis: We hypothesized that the size of Hill-Sachs lesions on pre-op MRI would be greater among patients who failed soft tissue stabilization when compared to patients who did not fail. We also hypothesized that the existence of a glenoid lesion would lead to failure with smaller Hill-Sachs lesions. Nested case-control analysis of 114 patients was performed to evaluate incidence of failure after soft tissue stabilization. Successful follow-up of at least 24 months was made with 91 patients (80%). Patients with recurrent instability after surgery were compared to randomly selected age and sex matched controls in a 1:1 ratio. Pre-operative sagittal and axial MRI series were analyzed for presence of Hill-Sachs lesions, and maximum edge-to-edge length and depth as well as location of the lesion related to the bicipital groove (axial) and humeral shaft (sagittal) were measured.Purpose
Method
Malalignment of some designs of stem is associated with an increased risk of aseptic loosening and revision. We investigated whether the alignment of the cemented polished, double-taper design adversely affected outcome, in a multicentre prospective study. A multicentre prospective study of 1189 total hip replacements was undertaken to investigate whether there is an association between surgical outcome and femoral stem alignment. All patients underwent a primary THR with the Exeter femoral stem (Stryker Howmedica Osteonics, Mahwah, NJ) and a variety of acetabular components. The primary outcome measure was the Oxford hip score (OHS) and change in OHS at five years. Secondary outcomes included rate of dislocation and revision. Radiographic evaluation of the femoral component was also undertaken. The long axis of the Exeter femoral component and the long axis of the femoral canal were located, and the angle at the point of intersection measured. The cementing quality was determined as defined by Barrack et al. Radiolucent lines at the cement-stem and cement-bone interface in the five year radiographs were defined using the zones described by Gruen et al. Subsidence was measured as the vertical dimension of the radiolucency craniolateral to the shoulder of the stem in Gruen zone 1 as described by Fowler et al. Cement fractures were recorded.Introduction
Methods
Tibial eminence fractures were historically thought of as a condition of skeletal immaturity. Increasingly this injury has been recognized in adults. The aim was to report on the demographics, mechanism, treatment and outcomes of this injury in adult and paediatric patients. A retrospective review of all patients presenting to Dunedin Hospital, for management of a displaced tibial eminence fracture, between 1989 and 2009. 19 cases were identified, 10 skeletally mature and 9 skeletally immature. Alpine skiing with a forced flexion and rotation injury accounted for 7 cases, primarily adult females (5 cases). A hyper-extension and rotation injury accounted for 7 cases, primarily in skeletally immature males (4 cases), while direct trauma accounted for 5 cases, primarily males (4 cases). Associated injuries were more commonly seen in adults and those with high energy trauma. Stiffness was the most common complication (10 cases). Tibial spine fractures are more common in adults than previously thought. Female skiers appear to be a group at particular risk. Our most common complication was stiffness. Early range of motion is essential to reduce the problem of stiffness and extension impingement. Laxity is an infrequent problem in adults and children.
Open cheilectomy is an established surgical treatment for hallux rigidus. Cheilectomy is now being performed using minimally invasive(MIS) techniques. In this prospective study we report the outcome of minimally invasive cheilectomy comparing the results with a matched group who had cheilectomy using standard open procedure. Prospective study of 47 patients. 22 patients had MIS cheilectomy between March 2009 and September 2010. We compared the outcome with a matched group (25 patients) who had open cheilectomy. Functional outcome was assessed using the Manchester Oxford Foot and ankle questionnaire (MOXFQ). The MOXFQ is a validated 16-item, patient-generated questionnaire designed to be self-completed and used as an outcome measure for foot surgery. It comprises three domains foot pain, walking and standing problems and social interaction. Total score ranges from 0 (best score) to 64 (worst score). Patients completed preoperative and postoperative questionnaires. Patients’ satisfaction and complications were recorded. In the MIS group, the median follow up was 11 months (4–23. The median preoperative MOXFQ score was 34/64(23) and the median postoperative score was 19/64 (p value <0.02) In the open group the median follow up was 17 months (9–27). The median preoperative MOXFQ score was 35/64 and the median postoperative score was 7.5/64 and this difference was statistically significant (<0.0001). There were three failures in the open group (Fusion) compared to none in the MIS. MIS cheilectomy is an effective alternative procedure with satisfactory functional outcome and high patient satisfaction. Results are comparable to the standard open cheilectomy with a lower apparent failure rate. The results of our randomised controlled trial comparing MIS cheilectomy to open cheilectomy are awaited.
Symptomatic hip disorders associated with cam deformities are routinely treated with surgery, during which the deformity is resected in an effort to restore joint range of motion, reduce pain, and protect the joint from further degeneration. This is a technically demanding procedure and the amount of correction is potentially critical to the success of the procedure: under-resection could lead to continued progression of the OA disease process in the joint, while over-resection puts the joint at risk for fracture. This study compares the accuracy of a new robotically assisted technique to a standard open technique. Sixteen identical Sawbones models with a cam type impingement deformity were resected by a single surgeon simulating an open procedure. An ideal final resected shape was the surgical goal in all cases. 8 procedures were performed manually using a free-hand technique and 8 were performed using robotic assistance that created a 3-dimensional haptic volume defined by the desired post-operative morphology. All of 16 sawbones, including uncut one as well, were scanned by Roland LPX-600 Laser scanner with 1mm plane scanning pitch and 0.9 degree of rotary scanning. Post-resection measurements included arc of resection, volume of bone removed and resection depth and were compared to the pre-operative plan.INTRODUCTION
METHODS
We present the results of a bi-centre, retrospective study examining the clinical, functional and radiological outcomes of distal radius fracture fixation with the Aptus locking plates and Tri-Lock® variable angle locking screws. We assessed 61 patients with distal radius fractures with a minimum of six months follow-up. Functional assessment was made using the DASH score. We measured wrist range of movement and grip strength, and reviewed radiographs to assess restoration of anatomy, fracture union and complications. All fractures united within six weeks. Mean ranges of movement and grip strength were only mildly restricted compared to the normal wrist. The mean DASH score was 18.2. Seven patients had screws misplaced outside the distal radius although 3 of these remained asymptomatic. Five other patients developed minor complications. Variable angle locking systems benefit from flexibility of implant positioning and may allow enhanced inter-fragmentary reduction for accurate fixation of intra-articular fractures. However, variable-angle systems may lead to increased rates of screw misplacement.
Despite the lack of robust evidence, numerous different track and trigger warning systems have been implemented. The MEWS (Modified Early Warning Score system) is one such example, and has not been validated in an emergency Identify whether the implementation of a MEWS system coupled with an outreach service had resulted in a reduction in the mortality within our unit.Introduction
Aim
Iliac crest bone marrow aspirate (ICBMA) is frequently cited as the ‘gold-standard’ source of MSCs. Mesenchymal stem cells have been shown to reside within the intramedullary (IM) cavities of long-bones and a comparative assessment with ICBMA has not yet been performed. Aspiration of the IM cavities of 6 patients' femurs with matched ICBMA was performed. The long-bone-fatty-bone-marrow (LBFBM) aspirated was filtered (70μm) and the solid fraction digested for 60min (37°C) with collagenase. Enumeration was performed via the colony-forming-unit-fibroblast (CFU-F) assay and using the CD45low CD271+ phenotype via flow-cytometry. Passaged (P2) cells were differentiated towards osteogenic, adipogenic and chondrogenic lineages with their phenotype assessed using flow-cytometry CD33 CD34 CD45 CD73 CD90 CD105.Introduction
Methods
Studies have suggested that there is a reduction in head-neck-ratio (HNR) associated with MoMHRA. A reduction in HNR at operation would decrease range of movement and increase impingement risk. Impingement could lead to 20 edge loading, increasing wear. Serum ion levels of Chromium (Cr) and Cobalt (Co) are surrogate markers of wear. Although acetabular component orientation has been shown to contribute to wear and PT development, the role of a decrease in HNR has only been highlighted in PT development. This study aimed to measure changes in HNR that occur at resurfacing and determine any gender- and component size-specific differences. In addition it aimed to determine whether changes in HNR could be associated with increased wear. 84 patients (56M: 28F) with unilateral MoMHRA were included. The mean age at surgery was 57 years. The mean femoral component was 49mm. Components were considered small if <45mm, average if between 45–50mm and large if >50mm. Three designs were implanted; BHR, C+ and Recap. The average follow up was 4 years. All patients had Cr/Co levels measured at follow up. Patients were considered to have high ions if Cr and Co levels were 5.1ppb and 4.4ppb respectively. Pre-operative HNR (HNRpre) and the post-operative HNR (HNRpost) were made from the respective pelvic radiographs. Assuming a 2mm thick cartilage layer, the HNR based on the diameter of the articular cartilage pre-operatively (HNRart) was calculated. The immediate changes in HNR as a result of the operation were expressed relative to articular HNR pre-op: HNRartpost=HNRpost–HNRartINTRODUCTION
METHODS
Electromagnetic navigation versus conventional Total Knee Arthroplasty: Clinical improvements Optical and electromagnetic (EM) tracking systems are widely used commercially. However in orthopaedic applications optical systems dominate the market. Optical systems suffer from deficiencies due to line of sight. EM trackers are smaller but are affected by metal. The accuracy of the two tracker systems has been seen to be comparable1. Recent advancements in optical navigated TKA have shown improved overall limb alignment, implant placement and reduce outliers when compared to conventional TKA2-4. This study is the first RCT to compare EM and conventional TKA. Two groups of 100 patients underwent TKA using either the EM navigation system or the conventional method. Frontal, sagittal and rotational alignment was analysed from a CT scan. Clinical scores including Oxford Knee Score (OKS) and Knee/Function American Knee Society Score (AKSS) were recorded pre-op, and at 3 and 12 months post-op. 3 month data presented includes 180 patients (n = 90). The 12 months data presented includes 140 (n = 70). The two groups had similar mean mechanical axis alignments (EM 0.31o valgus, conventional 0.15o valgus). The mechanical axis alignment was improved in the EM group with 92% within +/-3o of neutral compared to 84% of the conventional group (p = 0.90). The alignment of the EM group was improved in terms of frontal femoral, frontal tibial, sagittal femoral, sagittal tibial and tibial rotation alignment. However, only the sagittal femoral alignment was significantly improved in the EM group (p = 0.04). Clinically, both TKA groups showed significant improvements in OKS and AKSS scores between both pre-op to 3 month post-op and 3 months to 12 months post-op (p<0.001). The OKS and the AKSS knee score for the EM group was significantly better at 3 months post-op (OXS p = 0.02, AKSS knee p = 0.04). However there was no difference between the groups at 12 months. The mean pre-op range of motion (ROM) for both groups was 105o. This decreased to 102o in the EM group and 99o in the conventional group at 3 months. There was a significant improvement at 12 months post-op, EM = 113o (p = 0.012) and conventional = 112o (p = 0.026). There was no significant difference in ROM between the two groups at 3 or 12 months post-op. Therefore the alignment outcome of the EM TKA group was improved compared to the conventional group. The EM group also showed clinical improvements at 3 months post-op however these were not seen again at 12 months post-op. ROM was seen to decrease at 3 months post-op but then significantly improve by 12 month post-op.
Although simulation studies have shown superior wear properties of metal-on-metal articulations, increased concern exists regarding the excess in-vivo wear of a small number of Metal-on-Metal-Hip-Resurfacing (MoMHRA) implants. Serum ion levels of Chromium (Cr) and Cobalt (Co) are surrogate markers of wear. Risk factors associated with increased wear include female gender, small components, dysplasia, cup orientation outside safe zone and femoral head downsize during surgery with an associated decrease in Head-Neck-Ratio (HNR). However, these factors are interlinked. This study aims to identify the factors that are most important for subsequent wear of MoMHRA, by performing a multivariate analysis. 206 patients (124M: 82F) with unilateral MoMHRA were included in this study. The average follow up was 3.3 years. All patients had Cr/Co levels measured at follow up. Inclination and anteversion of each cup were measured using EBRA. Cups were analysed as being within or outside the previously defined optimum-zone. HNR measurements were made from pre-operative (HNRpre) and post-operative (HNRpost) radiographs. The immediate changes in HNR (downsize/upsize of femoral head) as a result of the operation were expressed as: HNRprepost=HNRpost–HNRpre Multivariate linear regression modelling was used to explore the association between measures of ions with the following predictor variables (gender, age, diagnosis, femoral component size, orientation of the acetabular component, head/neck ratio and position of femoral stem). Analyses were carried out separately for each outcome (Cr and Co). Classification and Regression Tree (CART) models were fitted as a complimentary approach to regression modelling.INTRODUCTION
METHODS
The introduction of hard-on-hard bearings and the consequences of increased wear due to edge-loading have renewed interest in the importance of acetabular component orientation for implant survival and functional outcome following hip arthroplasty. Some studies have shown increased dislocation risk when the cup is mal-oriented which has led to the identification of a safe-zone1. The aims of this prospective, multi-centered study of primary total hip arthroplasty (THA) were to: 1. Identify factors that influence cup orientation and 2. Describe the effect of cup orientation on clinical outcome. In a prospective study involving seven UK centers, patients undergoing primary THA between January 1999 and January 2002 were recruited. All patients underwent detailed assessment pre-operatively as well as post-op. Assessment included data on patient demographics, clinical outcome, complications and further surgery/revision. 681 primary THAs had adequate radiographs for inclusion. 590 hips received cemented cups. The primary functional outcome measure of the study was the change between pre-operative and at latest follow up OHS (OHS). Secondary outcome measures included dislocation rate and revision surgery. EBRA was used to determine acetabular inclination and version. The influence of patient's gender, BMI, surgeon's grade and approach on cup orientation was examined. Four different zones tested as possibly ± (Lewinnek Zone, Callanan's described zone and zones ± 5 and ±10 about the study's mean inclination and anteversion) for a reduced dislocation risk and an optimal functional outcome.INTRODUCTION
METHODS
The aim of this study was to determine whether the clinical outcome of autologous chondrocyte transplantation was dependent on the timing of a high tibial osteotomy in tibio-femoral mal-aligned knees. Between 2000 and 2005, forty-eight patients underwent autologous chondrocyte implantation with HTO performed at varying times relative to the second stage autologous chondrocyte implantation procedure. 24 patients had HTO performed simultaneously with their second stage cartilage transplantation, (the HTO Simultaneous Group). 5 patients had HTO prior to their cartilage procedure, (the HTO pre-ACI Group) and 19 had HTO performed between 1 to 4 years after their second stage cartilage implantation, (the HTO post-ACI Group). There were 29 men and 19 women with a mean age of 37 years (Range 28 to 50) at the time of their second stage procedure. With average follow-up of 72 months we have demonstrated a significant functional benefit in performing the HTO either prior to or simultaneously with the ACI procedure in the mal-aligned knee. The failure rate in the Post-ACI group was 45% compared to the Pre-ACI and Simultaneous group, with failure rates of 20% and 25%, respectively. An HTO performed prior to or simultaneously with an autologous chondrocyte implantation procedure in the mal-aligned knee, provides a significant protective effect by reducing the failure rate by approximately 50%.
Skeletal stem cells can be combined with human allograft, and impacted to produce a mechanically stable living bone composite. This strategy has been used for the treatment of femoral head avascular necrosis, and has been translated to four patients, of which three remain asymptomatic at up to three year follow-up. In one patient collapse occurred in both hips due to widely distributed and advanced AVN disease, necessitating bilateral hip arthroplasty. However this has provided the opportunity to retrieve the femoral heads and analyse human tissue engineered bone. Analysis of retrieved human tissue-engineered bone in conjunction with clinical follow-up of this translational case series.Background
Aims
Recent approaches have sought to harness the potential of stem cells to regenerate bone lost as a consequence of trauma or disease. Bone marrow aspirate (BMA) provides an autologous source of skeletal stem cells (SSCs) for such applications, however previous studies have demonstrated that the concentration of SSCs present in iliac crest BMA is below that required for robust bone regeneration. Here we present a novel acoustic-facilitated filtration strategy to concentrate BMA for SSCs, clinically applicable for intra-operative orthopaedic use. The aim of this study was to demonstrate the efficacy of this strategy in concentrating SSCs from iliac crest bone marrow, as well as femoral canal BMA from older patients. Iliac crest BMA (Lonza, Rockville, MD, USA) and femoral canal BMA was obtained with informed consent from older patients during total hip replacement. 5 to 40ml of BMA was processed via the acoustically-aided exclusion filtration process to obtain 2-8 fold volume reductions. SSC concentration and function was assessed by flow-cytometry, assays for fibroblastic colony-forming units (CFU-F) and multi-lineage differentiation along chondrogenic, osteogenic and adipogenic pathways examined. Seeding efficiency of enriched and unprocessed BMA (normalised to cell number) onto allograft was assessed. Iliac crest BMA from 15 patients was enriched for SSCs in a processing time of only 15 minutes. Femoral BMA from 15 patients in the elderly cohort was concentrated up to 5-fold with a corresponding enrichment of viable and functional SSCs, confirmed by flow cytometry and assays for CFU-F. Enhanced osteogenic (P<0.05) and chondrogenic (P<0.001) differentiation was observed using concentrated aspirate, as evidenced by biochemical assay and semi-quantitative histological analysis. Furthermore, enhanced cell seeding efficiency onto allograft was seen as an effect of SSC concentration per ml of aspirate (P<0.001), confirming the utility of this approach for application to bone regeneration. The ability to rapidly enrich BMA demonstrates potential for intra-operative application to enhance bone healing and offers immediate capacity for clinical application to treat many scenarios associated with local bone stock loss. Further in vivo analysis is ongoing prior to clinical tests.
Plasma levels of cobalt and chromium ions and
Metal Artefact Reduction Sequence (MARS)-MRI scans were performed
on patients with 209 consecutive, unilateral, symptomatic metal-on-metal
(MoM) hip arthroplasties. There was wide variation in plasma cobalt
and chromium levels, and MARS-MRI scans were positive for adverse reaction
to metal debris (ARMD) in 84 hips (40%). There was a significant
difference in the median plasma cobalt and chromium levels between
those with positive and negative MARS-MRI scans (p <
0.001).
Compared with MARS-MRI as the potential reference standard for the
diagnosis of ARMD, the sensitivity of metal ion analysis for cobalt
or chromium with a cut-off of >
7 µg/l was 57%. The specificity was
65%, positive predictive value was 52% and the negative predictive
value was 69% in symptomatic patients. A lowered threshold of >
3.5 µg/l for cobalt and chromium ion levels improved the sensitivity
and negative predictive value to 86% and 74% but at the expense
of specificity (27%) and positive predictive value (44%). Metal ion analysis is not recommended as a sole indirect screening
test in the surveillance of symptomatic patients with a MoM arthroplasty.
The investigating clinicians should have a low threshold for obtaining
cross-sectional imaging in these patients, even in the presence
of low plasma metal ion levels.
Fracture healing represents a physiological process regulated by a variety of signalling molecules, growth factors and osteogenic progenitor cells. Bone healing following trauma is associated with increased serum concentrations of several pro-inflammatory and angiogenic growth factors1. Platelet-derived growth factor (PDGF) has been shown to stimulate mesenchymal stem cell (MSC) proliferation in vitro. However, the in vivo relationship between the levels of PDGF and the numbers of MSCs in humans has not yet been explored. The aim of this study was to investigate PDGF release in the peripheral circulation following trauma and to correlate it with the numbers of MSCs in iliac crest bone marrow (BM) aspirate and in peripheral blood. Trauma patients with lower extremity fractures (n=12, age 18-63 years) were recruited prospectively. Peripheral blood was obtained on admission, and at 1, 3, 5 and 7 days following admission. The serum was collected and PDGF was measured using the enzyme-linked immuno-sorbent assay (ELISA) technique. Iliac crest (BM) aspirate (20ml) and peripheral blood (PB) (20ml) was obtained on days 0-9 following admission. MSCs were enumerated using standard colony-forming unit fibroblasts (CFU-F) assay.Background and objectives
Methods
Long bone fractures are a commonly presented paediatric injury. Whilst the possibility of either accidental or non-accidental aetiology ensures significant forensic relevance, there remain few clinical approaches that assist with this differential diagnosis. The aim of this current study was to generate a reproducible model of spiral fracture in immature bone, allowing investigation of the potential relationship between the rotational speed and the angle of the subsequent spiral fracture. Seventy bovine metacarpal bones were harvested from 7 day old calves. Sharp dissection ensured removal of the soft tissue, whilst preserving the periosteum. The bones were then distributed evenly before eleven groups, before being aligned along their central axis within a torsional testing machine. Each group of bones were then tested to failure at a different rotational speed (0.5, 1, 15, 20, 30, 40, 45, 60, 75, 80 and 90 degrees s-1). The angle of spiral fracture, relative to the long axis, was then measured, whilst the fracture location, the extent of comminution and periosteal disruption, were all recorded. Sixty-two out of 70 specimens failed in spiral fracture, with the remaining tests failing at the anchorage site. All bone fractures centred on the narrowest waist diameter, with 5 specimens (all tested at 90 degrees s-1) demonstrating comminution and periosteal disruption. The recorded spiral fracture angles ranged from 30 - 45 degrees, and were dependant on the rotational speed. This study has established a relationship between the speed of rotation and the angle of spiral fracture in immature bovine bone. It is anticipated that further study will enable investigation of this trend in paediatric bone, ultimately providing an additional diagnostic tool for clinicians trying to verify the proposed mechanism of injury.
Periprosthetic femoral fractures can occur as a complication of total hip arthroplasty and are often challenging to treat as the mechanical scenario is influenced by the presence of the metal prosthesis within the bone. This research focuses on finding the optimum fixation for transverse, Vancouver type B1 periprosthetic fractures, stabilised using locking plates and secured using screws. The aim of this study was to experimentally validate a computer model of a human femur, develop that model to represent a periprosthetic femoral fracture fixation and show how the model could be used to indicate differences between plating techniques. In the first development stage, both a laboratory model and a finite element model were developed to evaluate the mechanical behaviour of an intact composite femur under axial loading. Axial strains were recorded along the medial length of the femur in both cases and compared to provide validation for the computational model predications. The computational intact femur model was then modified to include a cemented total hip replacement, and further adapted to include a periprosthetic fracture stabilised using a locking plate, with unicortical screws above, and bicortical screws below the transverse fracture. For the intact femur case, the experimental and computational strain patterns correlated well with an average difference of 16%. Following the inclusion of the stem, there was a reduction in the strain in the region of the prosthesis reducing by an average of 45%. There was also a large increase in bulk stiffness with the introduction of the prosthesis. When the fracture and plate fixation were included, there was little difference in the proximal strain where the stem dominated, and the strains in the distal region were found to be highly sensitive to the distribution of the screws. The results of this study indicate that screw configuration is an important factor in periprosthetic fracture fixation. A laboratory model of the periprosthetic facture case is now under development to further validate the computational models and the two approaches will then be used to determine optimum fixation methods for a range of clinical scenarios.
Retrospective review of fusion rates using Grafton DBM/allografts only in AIS. Medical records of 30 consecutive patients at an average age of 19(18-24)were reviewed. All patients had segmental fixation with dual rod and pedicle screw construct followed by decortication supplemented with matrix strips/allograft chips. Minimum follow up 1.5 years, average of 2 years (1.5-3). First follow up at 3 months postoperatively and than 6 months subsequently. All patients were evaluated using criteria described by Betz et al for “possible pseudoarthrosis” which included persistent back pain, defects in the fusion mass, loosening of pedicle screws, junctional kyphosis and curve progression of more than 10 degrees from initial standing postoperative PA views. There were no infections. Average time to clinically and radiographically evident fusion was 12 months (range 10-16). Radiographically visible unfused facet joints were encountered in 3 patients towards the end of the construct. One patient had extension of the construct to treat junctional kyphosis. Other two remained asymptomatic. None had Progression of deformity. One patient developed pars defect at level below construct and was treated with extension of fusion.Purpose
Methods
Recent advancements in optical navigated TKA have shown improved overall limb alignment, implant placement and reduced outliers compared to conventional TKA. This study represents the first RCT comparing EM navigation and conventional TKA. 3D alignment was analysed from CT scans. Clinical scores (Oxford Knee Score (OKS) and American Knee Society Score (AKSS)) were recorded at pre-op, 3 and 12 months post-op. Data presented includes 180 patients (n=90 per group) at 3 months and 140 (n=70 per group) at 12 months. The groups had similar mean mechanical axis alignments (EM 0.31° valgus; conventional 0.15° valgus). Mechanical axis alignment however was improved in the EM group with 92% within +/−3° of neutral compared to 84% of the conventional group (p=0.90). The EM group showed improved coronal and sagittal femoral alignment and improved coronal, sagittal and rotational tibial alignment, which was significant for sagittal femoral alignment (p=0.04). The OKS and AKSS scores were significantly better for the EM group at 3 months post-op (OKS p=0.02, AKSS p=0.04), but there was no difference between groups at 12 months. The mean pre-op range of motion (ROM) for both groups was 105°. This decreased at 3 months to 102° in the EM group and 99° in the conventional group, but there was a significant improvement by 12 months: EM=113° (p=0.012) and conventional=112° (p=0.026). ROM was statistically similar between groups at all assessment phases. Knee alignment was better restored following EM navigated TKA relative to conventional TKA, but the difference was not significant. The EM group showed greater clinical improvements at early follow-up; however this difference was not sustained at 12 months. ROM was seen to decrease at 3 months but then significantly improve by 12 month post-op. Proving cost-effectiveness for navigation systems in TKA remains a challenge.
Patients with hip fracture are at high risk of venous thromboembolism (VTE). Chemical thromboprophylaxis with low molecular weight heparin (LMWH) is associated with a risk of major bleeding in certain patient groups, such as those with renal failure. In these patients, unfractionated heparin should be used. Our aim was to determine the practice of VTE risk assessment in patients admitted with hip fracture against the national guidance, which states that all should have VTE risk assessment on admission. We also assessed the impact of introducing the VTE risk assessment form on prescribing practice of chemical thromboprophylaxis in patients with renal failure. Prospective audit of patients of 50 patients admitted with hip fracture from 4/8/10 with re-audit of 50 patients admitted from 17/2/2011 after introducing the VTE risk assessment form into the hip fracture admissions proforma. Retrospective analysis was undertaken to determine chemical thromboprophylaxis prescribing in patients with eGFR <30ml/min/1.73m2. Patient demographics were comparable in both audit loops, with the mean age being equal (84 years) and an equal majority of female patients (76%). There were similar numbers of patients with eGFR <30ml/min/1.73m2 in both audit loops with 8% (n=4) in the initial audit, and 10% (n=5) in the re-audit. Frequency of VTE risk assessment significantly increased from 16% to 86% after including the VTE risk assessment form in the hip fracture proforma ( Documentation of VTE risk assessment in patients admitted with hip fracture can be improved by simple measures such as inclusion of the VTE risk assessment form in the admissions proforma. However, this did not result in a reduction of LMWH prescribed in patients with significant renal failure and risk of major bleeding.
The purpose of this study was to determine the accuracy of MRI scan for the detection of meniscal pathology in our unit. There are published data which show that both sensitivity and specificity can approach 90% when compared to arthroscopic findings. We retrospectively analysed a single surgeon series of 240 scopes for all indications The arthroscopic reports included an outline diagram of the meniscus upon which the surgeon recorded operative findings. 112 of these patients had also had recent MRI. We looked at whether the MRI report showed a tear, and this was graded Y/N. The arthroscopic report was graded for tear: Y/N. 66 patients had a positive scan. 64 of these were found to have a tear at surgery. 37 scans were reported as “no tear”, of which 4 were found to have a tear at surgery. Nine scans were not easy to classify as they were descriptive. In our series of 112 knees, MRI was 90.5% sensitive, 89.5% specific and 90.1% accurate. When a definite diagnosis of “tear”, or “no tear” was made at scan, there were two false positives and four false negatives. False positives may be unnecessarily exposed to the risks of surgery. Patients with negative scans had a mean delay to surgery of 33 weeks compared to 18 weeks for patients with positive scans. False negatives may wait longer for their surgery. Two of the false negative scans clearly showed meniscus tears which were missed by the reporting radiographer. In our series the scan itself was more accurate than the reporting. It is important to have an experienced musculoskeletal radiologist to minimise the number of missed tears. It is also important for surgeon to check the scan as well as the report.
Retrospective review of growth sparing spinal instrumentation. Medical records of 30 children with spinal deformity treated were evaluated. There were 14 male and 16 female patients at an average age of 4.9 years (1-14) at the time of presentation. These included 18 idiopathic, 11 congenital and a 14 year old with delayed growth having GH treatment. All patients underwent dual growing rod construct using hook and pedicle screw instrumentation. Extensions were carried out at approximately 6 monthly intervals. Average follow up was 4.2 years (2-8.5) with an average of 7.3(3-15) extension/exchange procedures per patient. Average immediate postoperative Cobb angle was 29(15-55) from a preoperative Cobb of 68(55-100) and this was maintained to a final mean Cobb angle of 30(15-60). Average gain in T1-S1 length was 5.7(3.5-9.8) cm. Five patients had final fusion at an average age of 15.5 years. There were no infections following primary operation. Out of 249 procedures including extensions/exchange, there were 9(4.5%) episodes of deep infection in 7 patients requiring debridement. Four patients (13%) had revisions for rod breakage/screw loosening/hook pullout/junctional kyphosis and three(10%) had prominent implants.Purpose
Methods and results
To establish the reliability of reporting and recording revision hip and knee arthroplasties by comparing data in the National Joint Registry (NJR), Hospital Episode Statistics (HES) and our local theatre records. The paper theatre registers for all orthopaedic theatres in the Royal Derby Hospitals NHS Trust were examined for details of revision hip and knee replacements carried out in 2007 and 2008. This was then cross-checked and merged with the local electronic theatre data to obtain a definitive local record of all revision hip and knee arthroplasties. Data for the same period was requested from the NJR and HES and these data were checked against our definitive local record for discrepancies. The HES codes used were the same codes used to compile the recent NJR annual reports.Purpose
Methods
Total knee arthroplasty (TKA) is an established and successful operation. However patient satisfaction rates vary from 81 to 89% 1,2,3. Pain following TKA is a significant factor in patient dissatisfaction 1. Many causes for pain following total knee arthroplasty have been identified 4 but rates of unexplained pain vary from 4 to 13.1% 5,6. Recently computerised tomography (CT) has been used to assess the rotational profile of both the tibial and femoral components in painful TKA We reviewed 57 patients with an unexplained painful following TKA and compared these to a matched control group of 60 patients with TKA. Datum gathered from case notes and radiographs using a prospective database to identify patients. The CT information recorded was limb alignment, tibial component rotation, and femoral component rotation and combined rotation. The two matched cohorts of patients had similar demographics. A significant difference in tibial, femoral and combined component rotation was identified between the groups. The following mean rotations were identified for the painful and control groups respectively. Tibial rotation was 3.46 degrees internal rotation (IR) compared to 2.50 degrees external rotation (ER)(p=0.001). Femoral rotation was 2.30 IR compared to 0.36 ER(p=0.02). Combined rotation was 7.08 IR compared to 2.85 ER(p=0.001). This is the largest study presently in the literature. We have identified significant internal rotation in a patient cohort with unexplained painful TKA when compared to a matched control group. Internal rotation of the tibial component, femoral component and combined rotation was identified as a factor in unexplained pain following TKA.
To determine the tensile forces across the knee extensor mechanism during walking, in simulated conditions of treatment. Gait analysis of six normal subjects was performed, with full weight bearing unilateral immobilisation of the knee during walking. Measurements were taken without then with a brace, unlocked then locked at 0°, 0-10°, 0-20° and 0-30° of flexion. Mean and maximum knee flexion angles were measured, followed by calculation of the mean and maximum forces across the extensor mechanism during loading, supporting and propulsion phases of gait.Aim
Methods
This study was undertaken to evaluate the early results of a new implant system - the metaphyseal sleeve - in revision total knee replacement. The femoral and tibial metaphyseal sleeves are a modular option designed to deal with metaphyseal bone loss and achieve cementless fixation over a relatively wide area in the metaphysis. Over three years, femoral and/or tibial metaphyseal sleeves were implanted in 104 knees in 103 patients (54 male and 49 female). The clinical notes and radiographs of these patients were reviewed retrospectively. Thirty one patients had revision for infection, 42 for aseptic loosening, and 31 for instability, pain or stiffness. Eighty nine knees were revised as a single stage and 15 were done as two stage procedure. Minimum follow up is 12 months (average 18.5 months).Purpose of the study
Methods
This review summarises the opinions and conclusions
reached from a symposium on infected total knee replacement (TKR)
held at the British Association of Surgery of the Knee (BASK) annual
meeting in 2011. The National Joint Registry for England and Wales
reported 5082 revision TKRs in 2010, of which 1157 (23%) were caused
by infection. The diagnosis of infection beyond the acute post-operative
stage relies on the identification of the causative organism by
aspiration and analysis of material obtained at arthroscopy. Ideal
treatment then involves a two-stage surgical procedure with extensive
debridement and washout, followed by antibiotics. An articulating
or non-articulating drug-eluting cement spacer is used prior to
implantation of the revision prosthesis, guided by the serum level
of inflammatory markers. The use of a single-stage revision is gaining popularity
and we would advocate its use in certain patients where the causative
organism is known, no sinuses are present, the patient is not immunocompromised,
and there is no radiological evidence of component loosening or
osteitis. It is our opinion that single-stage revision produces high-quality
reproducible results and will soon achieve the same widespread acceptance
as it does in infected hip arthroplasty.
The superficial anterior vasculature of the knee is variably described; most of our information comes from anatomical literature. Descriptions commonly emphasise medial-dominant genicular branches of the popliteal artery. Describing the relative contribution of medial and lateral vessels to the anastomotic network of the anterior knee may help provide grounds for selecting one of a number of popular incisions for arthrotomy. The aim of this study is to describe the relative contribution of vessels to anastomoses supplying the anterior knee. Cadaveric knees (n = 16) were used in two cohorts. The first cohort (n = 8) were injected at the popliteal artery with a single colour of latex, and then processed through a modified diaphanisation technique (chemical tissue clearance) before final dissection and analysis. This was repeated for the second cohort, but with initial dissection to identify potential source vessels at their origin. Each source vessel was injected with a different colour of latex. The dominant sources were determined in each specimen. The majority of the specimens (n = 13; 81%) demonstrated that an intramuscular branch though the vastus medialis muscle was the dominant vessel. Anastomoses were most common over the medial side of the knee, both superiorly and inferiorly (3-5 anastomoses in all cases). Anastomosis over the lateral knee was infrequent (1 anastomosis in 1 specimen). The results suggest that anterior vasculature of the knee is predominately medial in origin, but not from the genicular branches as previously described. This network of vessels found in the anterior knee is thought to be the main supply to the patella, extensor apparatus, anterior joint capsule and skin. Optimum placement of incision for arthrotomy is a subject of debate. Considering the main blood supply to the anterior knee may help in choosing a particular approach.
Cognitive impairment is common in patients with hip fracture both on admission and may develop later on. Reduced cognitive function is a risk factor for development of delirium, correlates with poor rehabilitation, and is an independent predictor of increased mortality. Despite its commonplace and potential for serious morbidity, cognitive dysfunction is often poorly assessed & diagnosed. Our aims were to 1) assess the practice of cognitive assessment on admission for hip fracture patients according to local guidelines and 2) ascertain whether it can be improved by the formal introduction of Abbreviated Mental Test Score (AMTS) & Clock Drawing Test (CDT) in the hip fracture admission proforma. A prospective audit was undertaken of cognitive assessment by either AMTS or CDT for 50 consecutive patients admitted with hip fracture from 4/8/2010. Subsequently, the hip fracture admission proforma was amended to include both the AMTS & CDT. A re-audit was performed on 50 consecutive patients admitted from 17/2/2011 to determine the change in practice. Patient demographics were comparable in both audit loops, with the mean age being equal (84 years) and an equal majority of female patients (76%). Cognitive assessment by either AMTS or CDT significant increased from 28% (n=14) to 86% (n=43) in the re-audit ( The assessment of cognitive function can be greatly improved by inclusion of both the AMTS & CDT to the hip fracture admission proforma, allowing the most appropriate multi-disciplinary care to be planned for the patient. Whilst both CDT and AMTS are good screening tools for cognitive impairment, many are unfamiliar with CDT & more training is needed.
Full-thickness burns around the knee can involve the extensor mechanism. The gastrocnemius flap is well described for soft tissue reconstruction around the knee. We describe a method where a Whichita Fusion Nail¯ knee arthrodesis, combined with a medial gastrocnemius muscle flap was used to salvage the knee and preserve the lower leg following a full-thickness contact burn. The gastrocnemius flap for wound coverage of an open knee joint was originally described in 1970 and remains the workhorse for soft tissue knee reconstruction. There are a number of local alternatives including the vastus lateralis, medialis and sartorius flap; and perforator flaps such as the medial sural artery perforator island flap and islanded posterior calf perforator flap, however many of these are unsuitable for larger defects. Full-thickness burns around the knee can put the extensor mechanism at risk and subsequent rupture is a possible consequence. The gastrocnemius flap has been used to cover a medial knee defect with exposed joint cavity following a burn and also been used in post burn contracture release around the knee. The primary indication for Wichita fusion nail is a failed total knee replacement. It allows intramedullary stabilization with compression at the arthrodesis site to stimulate bone union. With fusion rates reported up to 100% and low complication rates as compared to other methods of fusion, the technique has a useful role in limb salvage type procedures. While use of the gastrocnemius flap in knee burns has been described before we believe this is the first time that this combination of techniques, namely knee arthrodesis with soft tissue reconstruction using a gastrocnemius flap, has been reported. Combining these procedures with a multidisciplinary approach provides a useful alternative leading to limb salvage and avoiding the need for an above knee amputation when extensor reconstruction is not possible.
Stem geometry is known to influence the outcome in THA; however it is unknown whether the material properties, stiffness in particular can influence the stem stability and outcome. The aim of this study was to measure the influence of stem material properties on micromotion and migration using Roentgen Stereophotogrammetric Analysis (RSA) system. 41 patients were implanted with a collarless polished tapered (CPT) femoral stem (Zimmer, Warsaw, Indiana), which was made of either cobalt-chromium (CoCr) (n=21) or stainless steel (n=20). RSA was used to measure dynamically inducible micromotion (DIMM: difference in stem position in going from double-leg stance (DLS) to single leg stance (SLS)), prosthesis bending (difference in the head-tip distance when going from DLS to SLS), and mean migration of the head, tip and the cement restrictor. DIMM and bending were measured at 3 months, migration at 6, 12 and 24 months. All analyses were carried out using SPSS for windows (v.15.0.0, Chicago. IL, USA). Results were reported as mean ± 95% confidence interval (CI) and regarded as significant when p < 0.05. Preliminary analysis showed that total head DIMM was significantly (p = 0.02) greater for CoCr (0.97mm ± 0.6mm) than stainless steel (0.27mm ± 0.6mm). The mean stem bending for CoCr was 0.08mm (± 0.06mm) and for stainless steel 0.15mm (± 0.06mm) (p =0.77). Both implants heads migrated posteriorly, medially and distally. The mean subsidence for the cobalt-chromium and stainless steel stems was 1.02mm (± 0.19mm) (p < 0.001) and 1.12mm (± 0.34mm) (p=0.001) (p= 0.07) at 24 months. It was interesting to note that the dynamically induced micromotion was greater for the stiffer stem, however there were no differences in terms of overall migration, indicating that survival (in terms of loosening) should be the similar for both steel and CoCr versions of this implant.
To evaluate efficacy of blood conservation strategies on transfusion requirements in adult scoliosis surgery and establish a protocol for cross matching. Retrospective review of 50 consecutive adult scoliosis patients treated using anterior only(14,28%), posterior only(19,38%) or combined(17,34%) approaches. All patients were anaesthetised by the same anaesthetist implementing a standard protocol using cell salvage, controlled hypotension and antifibrinolytics. Mean age was 24.6 years. BMI was 21.9. On an average 9.5(6-15) levels were fused, with an average duration of surgery of 284.6(130-550) minutes. Antifibrinolytics were used in 31(62%) of the patients which included Aprotinin in 21(42%) and Tranexamic acid in 10(20%). Patients on antifibrinolytics had a significantly (p<0.05) lower blood loss (530ml) as compared to other patients (672ml). Mean volume of the cell saved blood re-transfused was 693.8 ml and mean postoperative HB level dropped to 10.7 g/dl(7.7-15) from a mean preoperative of 13.3 g/dl(10-17). 7(42%) with combined approaches and 3(15.8%) with posterior only approach required blood transfusion, 4/50(8%) of which required intra while 6/50(12%) required intra and postoperative transfusion. None of the patients having anterior surgery alone required blood transfusion.Purpose
Methods and Results
Total knee arthroplasty is an established and successful operation. In up to 13% of patients who undergo total knee arthroplasty continue to complain of pain. Recently computerised tomography (CT) has been used to assess the rotational profile of both the tibial and femoral components in painful total knee arthroplasty. We reviewed 56 painful total knee replacements and compared these to 56 matched patients with pain free total knee replacements. Patients with infection, aseptic loosening, revision arthroplasties and gross coronal malalignment were excluded. Datum gathered from case notes and radiographs using a prospective orthopaedic database to identify patients. The age, sex, preoperative and postoperative Oxford scores, visual analogue scores and treatments recorded. The CT information recorded was limb alignment, tibial component rotation, femoral component rotation and combined rotation. The two cohorts of patients had similar demographics. The mean limb alignments were 1.7 degrees varus and 0.01 degrees valgus in the painful and control groups respectively. A significant difference in tibial component rotation was identified between the groups with 3.2 degrees of internal rotation in the painful group compared to 0.5 degrees of external rotation in the control group (p=0.001). A significant difference in femoral component rotation was identified between the groups with 3.8 degrees of internal rotation in the painful group compared to 1.1 degrees of external rotation in the control group (p=0.001). A significant difference in the combined component rotation was identified between the groups with 6.8 degrees of internal rotation in the painful group compared to 1.7 degrees of external rotation in the control group (p=0.001). We have identified significant internal rotation in a patient cohort with painful total knee arthroplasty when compared to a control group with internal rotation of the tibial component, femoral component and combined rotation. This is the largest comparison series currently in the literature.
To investigate the effect of intraoperative wound irrigation with povidone-iodine on surgical site infection. Data were collected prospectively for all cases of instrumented thoracic and lumbar spine surgery undertaken by the senior author (DB) from 01/10/2008 to 1/10/2010. Variables recorded included patient factors (age, co-morbidities, drug history) and operative factors (type of operation, duration of operation, elective/emergency, in hours/out of hours, consultant/junior, perioperative antibiotic administration). Routine povidone-iodine application commenced on 1/06/2009. Surgical site infection was defined as wound infection confirmed on wound swab or blood cultures. Comparison was made between patients receiving povidone-iodine intraoperative wound irrigation and those who did not using Fisher's exact test.Aim
Methods
Anteromedial osteoarthritis of the knee (anteromedial gonarthrosis-AMG) is a common form of knee arthritis. In a clinical setting, knee arthritis has always been assessed by plain radiography in conjunction with pain and function assessments. Whilst this is useful for surgical decision making in bone on bone arthritis, plain radiography gives no insight to the earlier stages of disease. In a recent study 82% of patients with painful arthritis had only partial thickness joint space loss on plain radiography. These patients are managed with various surgical treatments; injection, arthroscopy, osteotomy and arthroplasty with varying results. We believe these varying results are in part due to these patients being at different stages of disease, which will respond differently to different treatments. However radiography cannot delineate these stages. We describe the Magnetic Resonance Imaging (MRI) findings of this partial thickness AMG as a way of understanding these earlier stages of the disease. 46 subjects with symptomatic partial thickness AMG underwent MRI assessment with dedicated 3 Tesla sequences. All joint compartments were scored for both partial and full thickness cartilage lesions, osteophytes and bone marrow lesions (BML). Both menisci were assessed for extrusion and tear. Anterior cruciate ligament (ACL) integrity was also assessed. Osteophytes were graded on a four point scale in the intercondylar notch and the lateral margins of the joint compartments. Scoring was performed by a consultant radiologist and clinical research fellow using a validated MRI atlas with consensus reached for disagreements. The results were tabulated and relationships of the interval data assessed with linear by linear Chi2 test and Pearson's Correlation.Introduction
Method
Frictional resistance to tendon gliding is minimised by surrounding loose areolar tissues. During periods of prolonged immobilisation, for example post tendon-repair, adhesions can form between the two adjacent tissues, thereby limiting function. Whilst agents applied during surgery are recognised to succeed in adhesion prevention, they have also been reported to provide some reduction in friction during
The risk of dislocation in large diameter metal on metal hip replacement is significantly lower than in standard THR. This is due to the increased primary arc, increased jump distance and possibly a suction effect. Our unit has performed over 1500 of these cases with an overall revision rate of <1%. We report a case series of dislocations in 5 large diameter metal on metal hips undertaken at our unit. All cases were reduced closed and investigated for cause of dislocation. Radiological investigation included plain film radiographs and CT to exclude component mal-position and MRI to document soft tissue deficiency. Metal ion levels were measured and microbiological investigation was undertaken.INTRODUCTION
METHOD
Many Accident and Emergency units employ a “one size fits all” policy with regard to referring patients with musculoskeletal injury for further review in fracture clinic. This may result in inappropriate timings of review in the clinic wasting patient time, clinic time and hospital resources. Our firm employs a rapid review of all radiographs and A&E notes of all musculoskeletal injury patients referred to our fracture clinic on a weekly basis. We aimed to investigate the impact this review has on the running of our clinic and what benefits were gained.Background
Aim
Femoral stem varus has been associated with poorer results. We report the incidence of varus/valgus malalignment of the Exeter polished, double taper design in a multicentre prospective study. The surgical outcomes at a minimum of five year and complication rates are also reported. A multicentre prospective study of 987 total hip replacements was undertaken to investigate whether there is an association between surgical outcome and femoral stem malalignment. The primary outcome measure was the change in the Oxford hip score (OHS) at five years. Secondary outcomes included the rate of dislocation and revision. The incidence of varus and valgus malignment were 7.1% and 2.6% respectively. There was no significant difference in OHS between neutral and malaligned femoral stems at 5 years (neutral, mean = 40.2; varus, mean 39.3, p = 0.465; valgus, mean = 40.9, p = 0.605). There was no significant difference in dislocation rate between the groups (p = 0.66). There was also no significant difference in revision rate (p = 0.34). This study provides evidence that the Exeter stem is extremely tolerant of varus and valgus malalignment, both in terms of outcome and complication rate.
Many of the questionnaire based scoring systems (i.e. Rowe score) require some form of clinical assessment. These clinical components can be very difficult to perform on a large scale particularly when a patient lives a long distance from clinic. We have attempted to counter this problem by asking the patient to asses their own range of motion. The aim of this study was to test the agreement between patient and clinician measured shoulder external rotation range using a photo based self-assessment tool. Fifty-one professional and semi-professional rugby players were recruited to assess shoulder external rotation range. Each player was presented with a photo based shoulder external rotation range self-assessment tool, which featured four photos of progressive shoulder external rotation in 2 positions, 900 abduction (150, 300, 450 & 600 of external rotation) and 00 abduction (700, 800, 900 & 1000 of external rotation). The players were asked to perform active external rotation in these two positions and mark the image which best matched their maximal external rotation. The player was then independently assessed using the same tool, by a clinician. The difference between the player's and the clinician's assessment was analysed using a weighted Kappa test. The Kappa for the shoulder external rotation in 900 abduction was 0.75 and 0.71 for left and right respectively, and 0.57 and 0.55 for shoulder external rotation in 00 abduction. Thus, the strength of agreement between the player's and clinician's assessment of shoulder external rotation is good in 900 abduction and moderate in 00 abduction. These results demonstrate that the photo-based shoulder external rotation range self-assessment tool is a very useful addition to researchers' and clinicians' toolkits and may be most useful when a patient lives a great distance from/or is unable to attend a clinic.
Avascular necrosis (AVN) of the femoral head is a potentially debilitating disease of the hip in young adults. Impaction bone grafting (IBG) of morcellised fresh frozen allograft is used in a number of orthopaedic conditions. This study has examined the potential of skeletal stem cells (SSC) to augment the mechanical properties of impacted bone graft and we translate these findings into clinical practice. We have examined the effect of SSC density on augmentation of bone formation. An in vitro model was developed to replicate the surgical IBG process. Plain allograft was used as the control, and the SSC's seeded at a density of 5×103, 5×104 and 2×105 cells per cc of allograft for the experimental groups. All samples were cultured for 2 weeks and mechanically tested to determine shear strength using the Mohr Coulomb failure curve. The approach was translated to 3 patients with early avascular necrosis (AVN) of the femoral head. The patient's bone marrow was concentrated in theatre using a centrifugation device and the concentrated fraction of SSC's were seeded onto milled allograft. The patient's necrotic bone was drilled, curetted and replaced with impacted allograft seeded with SSC's. Osteogenic potential of concentrated and unconcentrated marrow was simultaneously compared in vitro by colony forming unit assays.AIM
STUDY DESIGN
Iliac crest bone marrow aspirate (ICBMA) is frequently cited as the ‘gold-standard’ source of MSCs. MSCs have been shown to reside within the intramedullary (IM) cavities of long-bones [Nelea, 2005] however a comparative assessment with ICBMA has not yet been performed and the phenotype of the latter compartment MSCs remains undefined in their native environment. Aspiration of the IM cavities of 6 patients' femurs with matched ICBMA was performed. The long-bone-fatty-bone-marrow (LBFBM) was filtered (70μm) to separate liquid and solid fractions and the solid fraction was briefly (60min, 37oC) digested with collagenase. MSC enumeration was performed using the colony-forming-unit-fibroblast (CFU-F) assay and quantification of cells with the CD45low CD271+ phenotype by flow-cytometry. [Jones 2002, Buhring 2007] MSCs were cultured and standard expansion media and passage 2 cells were differentiated towards osteogenic, adipogenic and chondrogenic lineages.Introduction
Methods
Carpal tunnel decompression is common at the world's largest lamb processing plant. The purpose of this study was to establish whether lamb boning caused carpal tunnel syndrome, whether expeditious rehabilitation was possible and current New Zealand Orthopaedic practice. The incidences/relative risks of carpal tunnel syndrome were calculated. Kaplan-Meier survival analysis was performed examining six seasons. Comparison with a standard idiopathic population was performed. Retrospective review of five seasons established rate of return to work/complications using an accelerated rehabilitation programme. A prospective study qualified pre/postoperative symptoms using validated techniques. An email survey of the NZOA was also performed. Medical statistician advice was provided throughout.Introduction/aims
Method
“Increases in reconstructive orthopaedic surgery, resulting from advances in surgical practice and the ageing population, have lead to a demand for bone graft that far exceeds supply.”…Traditional bone grafting methods have been linked with a number of negative issues including increased morbidity due to secondary operation site and action as a vector for spread of disease. (Hing 2004). A solution to these insufficiencies would be the creation of a synthetic osteoinductive bone graft material. This would vastly improve bone graft surgery success rates and expedite post-op recovery times. The aim of this study was to classify then explore the dissolution rates of three experimental hydroxyapatite/silicate apatite synthetic bonegrafts in physiological solutions, (phosphate buffered saline, (PBS) +/− serum proteins, (PBS +FCS). The overall objective being to identify whether there is an explainable significant difference in ion exchange that could be behind the osteoinductive phenomena. Classification of the apatite samples, (HA, SA1 and SA2), was conducted via X-Ray diffraction, FTIR-PAS Spectroscopy and SEM with EDS analysis. A dissolution experiment of the experimental apatites was conducted in PBS and PBS + FCS solutions, over time periods of 1, 2 and 4 hours, and at 1, 2, 4 and 8 days, with repeat measures.Background, Context and Motivation
Methods Used
Therapeutic exploitation of MSCs in orthopaedics has been tempered by their scarcity within ‘gold-standard’ iliac crest bone marrow aspirate (ICBMA) and the resulting need to expand cells in vitro. This is time-consuming, expensive and results in cells with a reduced differentiation capacity. [Banfi 2000] The RIA is a device that provides continuous irrigation and suction during reaming of long bones. Aspirated contents pass via a filter, trapping bony-fragments, before moving into a ‘waste’ bag, from which MSCs have been previously isolated. [Porter 2009] We hypothesised that ‘waste’ RIA bag contains more MSCs than a standard aspirated volume of ICBMA (30 ml). We further hypothesised than a fatty solid phase within this ‘waste bag’ contains many MSCs trapped within the adipocyte-rich stromal network and hence requiring an enzymatic digestion for their efficient release [Jones 2006]. The discarded filtrate ‘waste’ bag that contained saline from marrow cavity irrigation procedure from RIA reaming (7 patients) was filtered (70μm) and the solid fraction digested for 60min (37oC) with collagenase. MSC enumeration was performed using the colony-forming-unit-fibroblast (CFU-F). Following culture in standard expansion media, passage 2 cells were differentiated towards osteogenic, adipogenic and chondrogenic lineages and their phenotype was assessed using flow cytometry. ICBMA from the same patients was used as controls.Introduction
Methods
The mechanical disadvantage and detrimental effect to articular cartilage following meniscectomy has been well documented in the literature. Meniscal repair in the avascular (white on white zone) is controversial and would be deemed inappropriate by many. Prospective data collection on all meniscal repairs between 1999 and 2008. 423 patients underwent meniscal repair at our unit during this time. We identified 88 patients who underwent a meniscal repair of a non peripheral tear (white on white zone) where there was no co-existent ACL injury or instability. There were 74 males and 14 females with a mean age of 26 years (13-54). There were 50 medial meniscal tears and 38 lateral tears, all in the non peripheral area of the meniscus. The criterion for failure was any reoperation on the same meniscus requiring excision or re fixation.Background
Methods
Spinal cord injury following trauma is initially dealt with by acute hospitals. The early management including stabilization is usually performed by these centres. This is followed by onward referral to one of the Regional Spinal Injury Units. There is concern of both sides of the fence regarding mobilization following spinal cord injury. The acute hospitals want to avoid the problems of prolonged recumbency and the Regional Spinal Injury Units wish to avoid the problems of early aggressive mobilization. Therefore, we set out to discover if there was a standard approach to mobilising these patients following surgical stabilization, because of the oversubscribed resources of the spinal injury units and the wish to start mobilizing the injured as soon as possible. A comparative audit of the Regional Spinal Injury Units in the UK and North American Units. Regional Spinal Injury Units in United Kingdom and North America Clear Management Plan Mobilisation Schedule We had replies from all Regional Spinal Injury Units in the UK and from seven in North America. The Regional Spinal Injury Units all had differing approaches. Only a few were able to convey a clear management plan and mobilization schedule. Whereas the North American Units provided a ‘mobilize as able’ plan in all cases. The North American Units had a ‘mobilize as able’ policy, whereas the UK units had a mixed approach. A coherent collaboration between the spinal surgeons stabilizing these injuries and the spinal injury units providing rehabilitation would improve patient management.
To assess adverse events related to XLIF approach in lumbar degenerative disease. Recently novel minimally disruptive spine procedure eXtreme lateral Interbody Fusion i.e XLIF has been developed. It is 90 (off the midline true lateral approach, which allows large graft placement, excellent disc height restoration and indirect decompression at the stenotic motion segment. We describe our experience in 28 patients. Retrospective review of records of patients undergoing surgery between July 2008- Jan 2010. Presenting complaints, number of levels performed and complications (medical, approach, or implant related) were audited. Results: 28 patients (17 female: 11 male) with median age of 47 yrs, range (38-75) formed the study group. Average stay was 4 days. All patients had MRI of lumbar spine. 2/3 rd patients had low back pain as their presenting complaint. All patients had nerve monitoring through out the procedure. There were 12 single, 15 two level and 1 three level cases (total 45 levels). 14/28 patients underwent plating at the same time. EBL was 100ml. There were 11/45 adverse events (24.4%). 6 events were approach, 4 were implant bone interface and 1 medical related. Major complication occurred in 1 patient (3.6%). 2/3 rd of patients, were better after the surgery. Almost negligible blood loss, low infection rate and short average stay seemed to work in favour of this approach. Complications are there as (with any new procedure) our results indicate, but these are manageable and less common with this technique. This did not require Ethics approval and there was no grant or industry support for the above.
Fracture of a ceramic component in total hip
replacement is a rare but potentially catastrophic complication.
The incidence is likely to increase as the use of ceramics becomes
more widespread. We describe such a case, which illustrates how
inadequate initial management will lead to further morbidity and
require additional surgery. We present the case as a warning that
fracture of a ceramic component should be revised to another ceramic-on-ceramic
articulation in order to minimise the risk of further catastrophic
wear.
We propose that Total Hip Replacement with correction of fixed flexion deformity of the hip and exaggerated lumbar lordosis will result in relief of symptoms from spinal stenosis, possibly avoiding a spinal surgery. A sequence of patients with this dual pathology has been assessed to examine this and suggest a possible management algorithm. A retrospective study of 19 patients who presented with dual pathology was performed and the patients were assessed with regards to pre and post-operative symptoms, walking distance, and neurological status.Introduction
Materials and methods
Brachial plexus blocks are used widely to provide intra-operative and post-operative analgesia. Their efficacy is well established, but little is known about discharging patients with a numb or weak arm. We need to quantify the risk of complications for improved informed consent. To assess whether patients can be safely discharged from hospital before the brachial plexus block has worn off and record any complications and concerns.Introduction
Objectives
Avascular meniscal tears can be repaired with good clinical outcomes. The mechanical disadvantage and detrimental effect to articular cartilage following meniscectomy has been well documented in the literature. Meniscal repair in the avascular (white on white zone) is controversial and would be deemed inappropriate by many.Hypothesis
Background
To determine the outcome, the need for revision surgery, quality of life (QOL) of patients and the financial implications of instability following successful closed reduction of dislocation after primary total hip arthroplasty (THA). Retrospective study. Parameters studied include indications for primary hip replacement, femoral head size, outcome in terms of the rate of recurrent dislocation, time to second dislocation and the need for revision surgery. QOL assessment was made cross-sectionally at a minimum follow-up of 1 year using the Oxford Hip Score (OHS) and the EuroQol-5 Dimension (EQ-5D) questionnaire.Aim
Methods
Review the results of modified Lautenbach procedure (new method) to treat chronic osteomyelitis of the long bones. Retrospective analysis of sixty-seven patients with osteomyelitis of the long bones treated over 5-year period with modified Lautenbach procedure. Four patients were excluded from this study, as we were unable to retrieve the case notes. 48 men and 16 women were included and the average age was 33 years. All these patients had prior operative intervention including plating, intramedullary nailing or external fixator. Forty-seven patients had discharging sinuses and deformed leg. We noted the pre-operative inflammatory markers, bacteriology and pain score. We also recorded the duration of the hospital stay, post-operative recovery, deformity and the ability of the patient to resume his prior occupation.Introduction
Patients and methods
This is a study of the quality of outcome of the first 100 patients who received the Twin Peg Oxford Partial knee replacement; which has been designed with a 15 degree extra surface for contact in deep flexion, and two pins for more secure fixation. We measured the outcome in patients with anteromedial osteoarthritis at 2 years after implantation using patient perception outcome measures: the OKS (Oxford Knee Score) and a patient satisfaction questionnaire. We also measured range of motion, the AKS (American Knee Society Score-Objective), the AFS (American Knee Society Score-Functional), and carried out a radiological assessment. The results showed a mean OKS of 41, a mean AKS of 93, a mean AFS of 84, a mean range of motion of 130 degrees and a 97% satisfaction rate. Results were significantly better in male patients. There were no deaths, infections, dislocations, fractures or revisions. There were no radiolucent lines of 2 mms or more at the femoral bone-cement interfaces. The introduction of this new version of the Oxford knee shows excellent clinical and radiological results which are at least as good as those seen with the Phase 3 Oxford Partial knee replacement. Small adjustments were made to the minimally invasive approach: a reduced invasive incision for ease of implantation. For those surgeons who are concerned over the risks of femoral loosening with the Phase 3 implant, or desire an improved surface area of contact at high angles of flexion, this Twin Peg Oxford Partial knee replacement offers an excellent alternative.
Simultaneous bilateral Total Knee Arthroplasty (TKA) has been reported to bring greater patient satisfaction, reduce in-patient stay and recovery, with similar outcomes to single sided or staged TKA, but higher complication rates. No validated selection criteria exist. We report the results of a single surgeon's experience of simultaneous bilateral TKA, using set guidelines for patient selection. A prospectively maintained database of all simultaneous bilateral TKA performed between 2002 and 2008 was retrospectively analysed, supplemented by case-note review. Outcome measures included length of stay, blood loss and transfusion rates, complications and functionality and validated outcome scores. 40 patients were included, 23 male and 17 female, all with osteoarthritis. Mean age was male 64.9 and female 61.3 years. Mean ASA grade was 1.8. All fitted selection criteria. Mean tourniquet time was right 79.1 minutes and left 83.6 minutes. Preoperative mean haemoglobin level was 141.8 g/dl and mean post operative level of 87.3 g/dl. 13 patients received purely autologous blood transfusion, 16 patients purely allogenic and 6 patients received both. There was 1 intraoperative complication (Medial collateral injury), 3 minor post operative complications which recovered prior to discharge. There were no thromboembolic events or deaths. Mean follow-up was 32.7 months (range 3-79 months). Mean in-patient stay was 7.5 days. Mean range of movement at most recent follow up was right 1.0 to 119.1 degrees flexion and left 1.0 to 120.8 degrees flexion. Mean Knee Society Scores pre- versus post-operatively were: 67 knee/62 function versus 90 knee/82 function. Oxford Knee Scores, Pre- versus post-operatively were: 43 versus 35 (Scoring 0-60, lowest best outcome). We demonstrate that with appropriate selection criteria, simultaneous bilateral TKA is safe and successful, giving excellent functional outcomes.
Bone marrow is an environment rich in its diversity of cell types and niches. Both hematopoietic and osteogenic stromal cells are present and have been studied extensively. Less is known about the function of one of the most abundant cell types in the bone marrow: adipocytes. There are several hypotheses that have been proposed including: passive role as a space filler; active role in the body's general lipid metabolism; role in providing a localized energy reservoir for emergency situations affecting the bone or hematopoiesis; support of differentiation or function of other cell types (such as bone, endothelial, and other stromal cells). There are several human pathologies associated with increases in adipocyte hypertrophy or proliferation including changes associated with aging, osteoporosis, and osteonecrosis. The reasons for these changes are poorly understood. One etiology associated with both osteoporosis and osteonecrosis, corticosteroid therapy, has been shown to increase the lipid content of osteoblasts and adipocytes. With osteonecrosis, several pathogenetic mechanisms involving adipocytes have been proposed: Mechanical - increased size and number cause increased intraosseous pressure and decreased venous outflow Direct precursor cells away from osteoblastogenesis towards adipogenesis Liquid fat causing a hypercoagulable state Osteocyte dysfunction or apoptosis Adipocyte and bone marrow necrosis Release adipokines and other factors that have an effect on the cells within the bone marrow (inhibiting angiogenesis, e.g.) The possibility that adipocytes may actually play an active role in propagating specific pathologic features has only recently been discussed. This is in part due to our increasing understanding that adipocytes have an endocrine role in metabolism. Only recently have scientists tried to identify specific cellular mechanisms that may be involved in the pathogenesis of osteonecrosis. Results from these studies will not only contribute to our understanding of the disease of osteonecrosis (and other diseases such as osteoporosis) but will also help us to appreciate the multiple functionalities of the heretofore unappreciated adipocyte.
To assess the accuracy of posterior and anterolateral methods of injection into the subacromial space (SAS) of the shoulder. Ethical approval was obtained and 50 patients (23 women and 27 men) with mean age of 64.5 years (42-87 years) and clinical diagnosis of subacromial impingement were recruited. Patients with old or recent shoulder fracture, bleeding disorders, and allergy to iodine were excluded. All injections were given by the consultant or an experienced registrar after obtaining informed consent. Patients were randomised into posterior and anterolateral groups and the method of injection was revealed by opening sealed envelopes just before the injection. A combination of 3mls 0.5% bupivacaine and 2mls of radiographic dye (Niopam) was injected in the subacromial space (SAS) using either anterolateral (n-22) and posterior approaches (28). AP and lateral radiographs of shoulder were taken after injection and were reported by a Consultant Radiologist blinded to the method of injection. Visual analogue scale (VAS) and Constant-Murley shoulder score was used to assess pain and function respectively. Both scores were determined before and 30 minutes after the injection.Aims
Patients and methods
Metal-on-Metal (MoM) hip bearings are being implanted in ever-increasing numbers and into ever-younger patients. The consequence of chronic exposure to metal ions is a cause for concern. Therefore, using cytogenetic biomarkers, we investigated a group of patients who have had MoM bearings in situ for in excess of 30 years. Whole blood specimens were obtained from an historical group of patients who have had MoM bearings in situ for in excess of 30 years. Blood was also obtained from an age and sex matched control group and from patients with Metal-on-Polyethylene (MoP) components of the same era. The whole blood was cultured with Pb-Max karyotyping medium and harvested for cytogenetics after 72 hrs. The 24 colour FISH (Fluorescent In Situ Hybridisation) chromosome painting technique was performed on the freshly prepared slides, allowing chromosomal mapping. Each slide was evaluated for chromosomal aberrations (deletions, fragments and translocations) against the normal 46 (22 pairs and two sex) chromosomes. At least 20 metaphases per sample were scored and the number of aberrations per cell calculated.Purpose
Method
We aimed (1) to determine the factors which influence outcome after surgery for CES and (2) to study CES MRI measurements. 56 patients with evidence of a sphincteric disturbance who underwent urgent surgery (1994-2002) were identified and invited to clinic. 31 MRIs were available for analysis and randomised with 19 MRIs of patients undergoing discectomy for persistent radiculopathy. Observers estimated the percentage of spinal canal compromise and indicated whether they thought the scan findings could produce CES and whether the discs looked degenerate. Measurements were repeated after two weeks. (1) 42 patients attended (mean follow up 60 months; range 25–114). Mean age at onset was 41 years (range 24–67). 26 patients were operated on within 48 hours of onset. Acute onset of sphincteric symptoms and the time to operation did not influence the outcomes. Leg weakness at onset persisted in a significant number at follow-up (p<0.005). Bowel disturbance at presentation was associated with sexual problems (<0.005) at follow-up. Urinary disturbance at presentation did not affect the outcomes. The 13 patients who failed their post-operative trial without catheter had worse outcomes. The SF36 scores at follow-up were reduced compared to age-matched norms in the population. The mean ODI was 29, LBOS 42 and VAS 4.5. (2) No significant correlations were found between MRI canal compromise and clinical outcome. There was moderate to substantial agreement for intra- and inter-observer reproducibility. Due to small numbers we cannot make the conclusion that delay to surgery influences outcome. Based on the SF36, LBOS and ODI scores, patients who have had CES do not return to a normal status. Using MRI alone, the correct identification of CES has sensitivity 68%, specificity 80% positive predictive value 84% and negative predictive value 60%. CES occurs in degenerate discs.Conclusions
In suspected scaphoid fracture the initial scaphoid series plain radiographs are 84-94% sensitive for scaphoid fractures. Patients are immobilised awaiting diagnosis. Unnecessary lengthy immobilisation leads to lost productivity and may leave the wrist stiff. Early accurate diagnosis would improve patient management. Although Magnetic Resonance Imaging (MRI) has come to be regarded as the gold standard in identifying occult scaphoid injury, recent evidence suggests Computer Tomography (CT) to be more accurate in identifying scaphoid cortical fracture. Additionally CT and USS are frequently a more available resource than MRI. We hypothesised that 16 slice CT is superior to high spatial resolution Ultrasonography (USS) in the diagnosis of radiograph negative suspected cortical scaphoid fracture and that a 5 point clinical examination will help to identify patients most likely to have sustained a fracture within this group. 100 patients with two negative scaphoid series and at least two out of five established clinical signs of scaphoid injury (anatomical snuffbox tenderness (AST), scaphoid tubercle tenderness (STT), effusion, pain on circumduction and pain on axial loading) were prospectively investigated with CT and USS. MRI was arranged for patient with persistent symptoms but negative CT/USS.Background
Methods
Pre-operative urine screening is accepted practice during pre-operative assessment in elective orthopaedic practice. There is no evidence surrounding the benefits, effects or clinical outcomes of such a practice. A series of 558 patients undergoing elective admission were recruited during pre-assessment for surgery and were screened for UTIs according to a pre-existing trust protocol. All patients had their urine dipstick tested and positive samples were sent for culture and microscopy. Patients with a positive urine culture were treated prior to surgery and were admitted to the elective centre where strict infection control methods were implemented. The patients were followed up after their surgery and divided into three clinical groups: uneventful surgery; Suspected wound infection; Confirmed wound infectionIntroduction
Methods
Elective Orthopaedics has been targeted by the UK Department of Health as a maximum six-month waiting time for operations could not be met. The National Orthopaedic Project was initiated as a consequence and Independent Sector Treatment Centres (ISTCs) and well established private hospitals were utilised to treat NHS long wait patients. We audited the primary total hip replacements performed in our hospital in 1998 and 2003 to compare the differences in the patient characteristics in particular age, length of stay and ASA grade.Introduction
Materials and methods
Unicompartmental knee replacements (UKR) converted to total knee replacements (TKR) have often been viewed with scepticism because of the perceived difficulty of the revision and because revision procedures generally do less well than primaries. This is a prospective review of TKRs converted from a UKR between 1982 and 2000. We present the survivorship of a 77 patient cohort and the clinical results of 35 patients. All information was recorded at the time of surgery onto a database and patients have been regularly reviewed since.Background
Methods
This study was to investigate the association of developmental dysplasia of the hip (DDH) and primary protrusion acetabuli (PPA) with Vitamin D receptor polymorphisms TaqI and FokI and oestrogen receptor polymorphisms Pvu II and XbaI. 45 patients with DDH and 20 patients with PPA were included in the study. Healthy controls (n=101) aged 18-60 years were recruited from the same geographical area. The control subjects had a normal acetabular morphology based on a recent pelvic radiograph performed for an unrelated cause. DNA was obtained from all the subjects from peripheral blood. Genotype frequencies were compared in the three groups. The relationship between the genotype and morphology of the hip joint, severity of the disease, age at onset of disease and gender were examined.Introduction
Methods
To report a retrospective study of 103 cases of primary spinal infection, the largest ever such series from the UK, analysing presenting symptoms, investigations, bacteriology and the results of treatment. This is a retrospective review of all patients (54 Male, 49 Female) treated for primary spinal infection in a Teaching Hospital in the UK.Purpose
Method
We obtained pre-operative and six-month post-operative
Oxford hip (OHS) and knee scores (OKS) for 1523 patients who underwent
total hip replacement and 1784 patients who underwent total knee
replacement. They all also completed a six-month satisfaction question. Scatter plots showed no relationship between pre-operative Oxford
scores and six-month satisfaction scores. Spearman’s rank correlation
coefficients were -0.04 (95% confidence interval (CI) -0.09 to 0.01)
between OHS and satisfaction and 0.04 (95% CI -0.01 to 0.08) between
OKS and satisfaction. A receiver operating characteristic (ROC) curve
analysis was used to identify a cut-off point for the pre-operative
OHS/OKS that identifies whether or not a patient is satisfied with
surgery. We obtained an area under the ROC curve of 0.51 (95% CI
0.45 to 0.56) for hip replacement and 0.56 (95% CI 0.51 to 0.60)
for knee replacement, indicating that pre-operative Oxford scores
have no predictive accuracy in distinguishing satisfied from dissatisfied
patients. In the NHS widespread attempts are being made to use patient-reported
outcome measures (PROMs) data for the purpose of prioritising patients
for surgery. Oxford hip and knee scores have no predictive accuracy
in relation to post-operative patient satisfaction. This evidence
does not support their current use in prioritising access to care.
Of the 76 hips that were MRI scanned, 27 (36%) had typical features of a MOM reaction. These were classified as mild in 10 (13%), moderate in 13 (17%) and severe in 4 (5%). 78 patients completed an OHS and the mean score was 21. The mean OHS was 29 pre-operatively in those that had been revised, 25 in patients with abnormal MRI findings and 20 in those with a normal MRI. 10 patients with abnormal MRIs had a near perfect OHS (15 or less)
Excessive implant migration and micromotion have been related to eventual implant loosening. The aim of this project is to develop a computational tool that will be able to predict the mechanical performance of a cementless implant in the presence of uncertainty, for example through variations in implant alignment or bone quality. To achieve this aim, a computational model has to be developed and implemented. However, to gain confidence in the model, it should be verified experimentally. To this end, the present work investigated the behavior of a cementless implant experimentally, and compared the results with a computational model of the same test setup. A synthetic bone (item 3406, Sawbones Europe AB, Sweden) was surgically implanted with a Furlong cementless stem (JRI, Sheffield, UK) in a neutral position and subjected to a compression fatigue test of −200 N to −1.6 kN at a frequency of 0.5 Hz for 50000 cycles. Measurements of the micromotion and migration were carried out using two linear variable differential transducers and the strain on the cortex of the femur was measured by a digital image correlation system (Limess Messtechnik &
Software Gmbh). A three-dimensional model was generated from computed tomography scans of the implanted Sawbone and converted to a finite element (FE) model using Simple-ware software (Simpleware Ltd, Exeter, UK). Face-to-face elements were used to generate a contact pair between the Sawbone and the implant. A contact stiffness of 6000 N/m and a friction coefficient of 0.3 were assigned. The analysis simulated a load of −1.6 kN applied to the head of the implant shortly post implantation. The motions and strains recorded in the experiment were compared with the predictions from the computational model. The micromotion (the vertical movement of the implant during a single load cycle), was measured at the proximal shoulder, at the distal tip of the implant and at the bone-implant interface. The maximum value calculated proximally using FE was 61.3 μm compared to the experimental value of 59.6 μm. At the distal end, the maximum micromotion from FE was 168.9 μm compared to 170 μm experimentally. As a point of reference, some authors have suggested that in vivo, fibrous tissue formation may take place at the bone-implant interface when the micromotion is above 150 μm. The maximum micromotion found computationally at this interface was 99 μm which is below the threshold value defined. The longitudinal strain over the surface of the bone was variable and reached values of up to 0.15% computationally and 0.4% experimentally; this may be related to the coordinate systems used. However, it was noted that digital image correlation identified qualitatively similar strain patterns, and has great potential for measuring low level surface strains on bone. In conclusion, the good correlation between the computational modelling and experimental tests provides confidence in the model for further investigations using probabilistic analyses where more complex configurations (for example change in implant alignment) can be analyzed.
Minimally invasive total knee arthroplasty is purported to have a number of patient benefits: reduced post-operative pain, earlier mobilisation, and shorter in-patient stay. However, previous literature has identified the existence of a learning curve that may render the procedure unsuitable for low-volume arthroplasty surgeons. Via retrospective analysis, we set out to compare the incidence of major and minor complications during the first eighty-four minimally invasive total-knee replacements (NexGen; Zimmer UK) undertaken by a single high-volume arthroplasty surgeon starting in April 2004. The eighty-four patients were sub-divided into four chronological groups (twenty one patients each, designated A, B, C &
D respectively). Fifty-three patient records were available for analysis. These comprised: Group A (n=17), Group B (n= 13), Group C (n= 10), and Group D (n=13), with a mean follow-up of 21 months. Three patients had rheumatoid arthritis, whilst the remaining fifty had osteoarthritis. There were two major and five minor complications in Group A, one major complication in Group B, one major and one minor complication in Group C, and two minor complications in Group D. Employing a Turkey post hoc ANOVA test, no significant differences were found between the groups when comparing overall complications, or when comparing minor and major complications as separate entities (PASW Statistics 17 for Windows, Chicago, Illinois). To conclude, although a higher complication rate was observed in this group of patients during the first twenty minimally invasive total knee arthroplasties, this difference was not statistically significant. A follow-up study will analyse the postoperative results of a more recent cohort of patients.
From a global point of view, chronic haematogenous osteomyelitis in children remains a major cause of musculoskeletal morbidity. We have reviewed the literature with the aim of estimating the scale of the problem and summarising the existing research, including that from our institution. We have highlighted areas where well-conducted research might improve our understanding of this condition and its treatment.
T8-L4 fusion and facet capsulotomy at L4–L5 and L5-S1; L4–L5 Maverick; L5-S1 Maverick. Maverick total disc replacement and fusion with the CD Horizon system was performed. Repeated measures ANOVA was used to analyze changes in ROM and HAM of the L4–L5 and L5-S1 segments.