EARLY RESULTS OF PYROCARBON PIP JOINT REPLACEMENT: EXPERIENCE OVER 4 YEARS



Abstract

Background: PIP joint surface replacement has been shown to be effective in the treatment of arthritis. We performed a retrospective review to evaluate the clinical results and functional outcome of pyrocarbon proximal interphalangeal joint replacement, motion preserving and function in selected patients.

Method: The patients who underwent pyrocarbon PIP joint arthroplasty by the two senior authors were reviewed. Clinical assessment included range of motion, degree of pain and deformity pre and post operatively. Independent functional scores were collected. Radiographs were reviewed for evidence of loosening, fracture and dislocation. Patient overall satisfaction was assessed.

Results: 25 patients had 27 pyrocarbon PIP joint replacements between 2004 and 2008. Of these patients, there were 21 female (84%) and 4 male (16%) with average age of 62.5 (43–78). Indications for surgery were pain and loss of function. The preoperative diagnosis was post traumatic osteoarthritis in 9 (33.3%) and primary osteoarthritis in 18 (66.7%). The average arc of motion preoperatively was 42.3 (5–60), and the average postoperative one was 74.3 (45–100). Pain was relieved in majority of patients. 23 patients (92%) were satisfied completely with the procedure. Pain was relieved in the majority of cases and we had 2 dislocations requiring revision to silicone joint replacement and 2 adhesions/stiffness requiring tenolysis. There were no infections.

Conclusion: Our experience of pyrocarbon PIP joint replacement over the 4 years showed this implant is useful for relief of pain and function. A technically demanding procedure, it improves arc of motion, corrects deformity and achieves satisfactory function. We had 7 % revision rate and longer term follow-up is required.


Correspondence should be sent to: Mohamad Hachem, Norfolk and Norwich University Hospital, Trauma & Orthopaedics, Norwich, United Kingdom; Peterborough & Stamford Hospitals, Peterborough, United Kingdom, hachem.mohamad@nnuh.nhs.uk

The abstracts were prepared by Mr Matt Costa and Mr Ben Ollivere. Correspondence should be addressed to Mr Costa at Clinical Sciences Research Institute, University of Warwick, Clifford Bridge Road, Coventry CV2 2DX, UK.