Full Access

Research

COMPUTERISED TOMOGRAPHY ROTATIONAL ALIGNMENT IN PAINFUL TOTAL KNEE ARTHROPLASTY A MATCHED COHORT STUDY

West of Scotland Orthopaedic Research Society (WOSORS) - 4th Annual Meeting



Abstract

Total knee arthroplasty is an established and successful operation. In up to 13% of patients who undergo total knee arthroplasty continue to complain of pain. Recently computerised tomography (CT) has been used to assess the rotational profile of both the tibial and femoral components in painful total knee arthroplasty.

We reviewed 56 painful total knee replacements and compared these to 56 matched patients with pain free total knee replacements. Patients with infection, aseptic loosening, revision arthroplasties and gross coronal malalignment were excluded. Datum gathered from case notes and radiographs using a prospective orthopaedic database to identify patients. The age, sex, preoperative and postoperative Oxford scores, visual analogue scores and treatments recorded. The CT information recorded was limb alignment, tibial component rotation, femoral component rotation and combined rotation.

The two cohorts of patients had similar demographics. The mean limb alignments were 1.7 degrees varus and 0.01 degrees valgus in the painful and control groups respectively. A significant difference in tibial component rotation was identified between the groups with 3.2 degrees of internal rotation in the painful group compared to 0.5 degrees of external rotation in the control group (p=0.001). A significant difference in femoral component rotation was identified between the groups with 3.8 degrees of internal rotation in the painful group compared to 1.1 degrees of external rotation in the control group (p=0.001). A significant difference in the combined component rotation was identified between the groups with 6.8 degrees of internal rotation in the painful group compared to 1.7 degrees of external rotation in the control group (p=0.001).

We have identified significant internal rotation in a patient cohort with painful total knee arthroplasty when compared to a control group with internal rotation of the tibial component, femoral component and combined rotation. This is the largest comparison series currently in the literature.