header advert
Orthopaedic Proceedings Logo

Receive monthly Table of Contents alerts from Orthopaedic Proceedings

Comprehensive article alerts can be set up and managed through your account settings

View my account settings

Visit Orthopaedic Proceedings at:

Loading...

Loading...

Volume 99-B, Issue SUPP_8 April 2017 European Orthopaedic Research Society (EORS) 2015, Annual Conference, 2–4 September 2015. Part 1.

G.J. Walkden S. Lewis J. Soar

Background

The National Confidential Enquiry into Perioperative Deaths recommends that high-dependency (HDU) or intensive care unit (ICU) care is available following arthroplasty. In hospitals without dedicated post-operative care units, patients can be transferred to wards more rapidly, which is associated with adverse surgical outcome, increased morbidity & mortality and unplanned HDU/ICU admission. Pre-operative assessment clinics (POAC) have been demonstrated to reduce these adverse outcomes. We present an evaluation of HDU/ICU admissions and a micro-cost effectiveness evaluation of POAC and planned HDU/ICU admission in hip/knee arthroplasty.

Methods

Data were obtained retrospectively for all patients undergoing hip/knee arthroplasty between 01/06/2013–30/06/2014 at North Bristol NHS Trust. n=2258 admissions were linked across coding, ICU (WardWatcher), and Myocardial Ischaemia National Audit Project databases. POAC records and patient notes were hand-searched for n=83 admissions to HDU/ICU. Cost estimates were derived from clinical coding and length-of-stay. The work was performed in STATA and registered under Trust ID 15545.


J. Blackburn D. Lim I. Harrowell M. Parry A.W. Blom M.R. Whitehouse

Background

Over 96% of primary total hip replacements (THR) recorded in the National Joint Registry (NJR) are performed through a posterior or lateral surgical approach. There is no high quality evidence available to support the use of one approach over the other in primary THR and even less evidence when the outcome of revision THR is considered.

Methods

Questionnaires were sent to 267 patients who had revision hip replacements between January 2006 and March 2010 for aseptic loosening. They rated their pain from 0–10, and used the Self-Administered Patient Satisfaction Scale (SAPS), Oxford Hip Score (OHS), Western Ontario and McMaster University Osteoarthritis Index (WOMAC) and Short form-12 (SF-12).


A.J. Grazette J. Foote M.R. Whitehouse A.W. Blom

Background

Dissociation of the polyethylene liner is a known failure mechanism of the Harris Galante I and II uncemented acetabular components. The outcomes of revision surgery for this indication and the influence of time to diagnosis are not well described.

Methods

We report a series of 29 cases revised due to this failure mechanism.


O. Hapa O. Başçı L. Horoz F. Ertem A. Karakaşlı H. Havitçioglu

Background

Acetabular labral tears can cause pain and microinstability and are the most common indication for hip arthroscopy. Hip labral repair demonstrates better clinical outcome scores at a mean of 3.5 years post surgery than labral excision and tends to be performed in a younger age group. While different labral stitch configurations are possible, the most frequently used are a mattress stitch passed though the hip labrum at its widest part, or a simple loop surrounding the labrum. To determine the strength of variousrepair techniques and the impact suture passer sizesonhip labrum failure after cyclic loading.

Methods

35 unattached fresh-frozen bovine hip labrums were assigned to 5 repair techniques (7 specimens each): Group 1: horizontal mattress using a penetrating grasper; Group 2: vertical mattress using a penetrating grasper; Group 3: vertical mattress using asuture lasso; Group 4: Oblique repair using a penetrating grasper; Group 5: vertical mattress using a penetrating grasper and monopolar radio frequency device. Using a materials testing machine and after a 10N preload, each contruct was subjected to 20 cycles at 5N–80N. Cyclic elongation, peak-to-peak displacement, ultimate failure load, stiffness, and failure mode were recorded.


A.A. Alshuhri A.W. Miles J.L. Cunningham

Introduction

Aseptic loosening of the acetabular cup in total hip replacement (THR) remains a major problem. Current diagnostic imaging techniques are ineffective at detecting early loosening, especially for the acetabular component. The aim of this preliminary study was to assess the viability of using a vibration analysis technique to accurately detect acetabular component loosening.

Methods

A simplified acetabular model was constructed using a Sawbones foam block into which an acetabular cup was fitted. Different levels of loosening were simulated by the interposition of thin layer of silicon between the acetabular component and the Sawbones block. This included a simulation of a secure (stable) fixation and various combinations of cup zone loosening. A constant amplitude sinusoidal excitation with a sweep range of 100–1500 Hz was used. Output vibration from the model was measured using an accelerometer and an ultrasound probe. Loosening was determined from output signal features such as the number and relative strength of the observed harmonic frequencies.


Full Access
J.P. Kretzer R. Sonntag H. Kiefer J. Reinders A. A. Porporati R. Streicher

Background

The CoCrMo large bearings had shown a high failure rate, because of metal ion and particle release. Alumina matrix composite (AMC) ball heads have shown to mitigate such phenomena. The aim of this study was to investigate the leaching properties of AMC clinically as well as experimentally.

Methods

Two patient groups were compared: a control group (n=15) without any implant (Controls) and 15 Patients with unilateral treatment with Biolox delta ceramic-on-ceramic (CoC). Whole-blood samples of Controls and Patients (after 3 and 12 months from treatment with CoC) were measured by means of trace element analysis using a HR-ICPMS. The leaching behaviour of BIOLOX delta was also analysed in-vitro: five Biolox delta heads and five CoCrMo heads were immersed in serum for seven days at 37°C. Aluminium, cobalt, chromium and strontium were detected based on HR-ICPMS.


A. Karakaşlı F. Ertem N.D. Demirkıran Y.E. Bektaş H. Havıtçıoğlu

Background

Currently about 4–6% of all femur fractures consist of distal femoral fractures. Different methods and implants have been used for the surgical treatment of distal femoral fractures, including intramedullary nails. Retrograde nail. By contrast with antegrade nails, surgical approach or retrograde nailing exposes the knee joint which may lead to tendency of infection and increased knee pain. Present study aims to compare the biomechanical behaviour of distal angular condyler femoral intramedullary nail (DACFIN), retrograde nail and plate fixation.

Methods

Fifteen 4th generation Saw bones were used to evaluate the biomechanical differences between the groups (Group 1: Plate fixation, Group 2: Retrograde nailing, Group 3: DACFIN; (n=5)). Biomechanical test was performed by using an electromechanical test device Shimadzu (AG-IS 5kN, Japan). Displacement values were recorded by using a Non-contact Video Extensometer (DVE-101/201, Shimadzu, Japan) during the loading each femur with 5 cycles of 500 N at a rate of 10 N/s to determine axial stiffness. The faliure stiffness was measured by axial load to each constructat a displacement rate of 5 mm/min. Torsional loading applied to all groups in amount of 6 Nm of torque with a velocity of 18 degrees/min.


I. Ahmed P. Wall L. Fraser A. Sprowson

Background

Tourniquets are routinely used in total knee arthroplasty (TKA) with an estimated use by up to 93% of surgeons. Advantages include the ability to provide a bloodless field of view to facilitate cement application and increase the success of the procedure. Overall reduction in blood loss is another perceived advantage, however recent research has demonstrated no measurable reduction and conversely a substantial increase in complications such as deep vein thrombosis and systemic emboli. Given the significant complications of tourniquet use we aim to identify patients' views on tourniquets and of emphasis their awareness of the possible risks involved prior to the procedure.

Method

A questionnaire-based study was carried out on 35 patients attending an elective orthopaedic centre for TKA surgery. Ethical approval was granted by NRES committee – East of England (REC Ref: 14/EE/1265). Patients were provided with an information sheet detailing the reasons for the tourniquet use and the associated risks and benefits. They were then provided with a questionnaire to ascertain their views and previous understanding of the subject. Simple statistical measures were implemented to analyse the data.


V. Wylde E. Lenguerrand R. Gooberman-Hill A.D. Beswick E. Marques S. Noble J. Horwood M. Pyke P. Dieppe A.W. Blom

Background

Total hip replacement (THR) and total knee replacement (TKR) are usually effective at relieving pain; however, 7–23% of patients experience chronic post-surgical pain. These trials aimed to investigate the effect of local anaesthetic wound infiltration on pain severity at 12 months after primary THR or TKR for osteoarthritis.

Methods

Between November 2009 and February 2012, 322 patients listed for THR and 316 listed for TKR were recruited into a single-centre double-blind randomised controlled trial. Participants were randomly assigned (1:1) to receive local anaesthetic infiltration and standard care or standard care alone. Participants and outcomes assessors were masked to group allocation. The primary outcome was pain severity on the WOMAC Pain scale at 12 months post-surgery. Analyses were conducted using intention-to-treat and per-protocol approaches. Ethics approval was obtained from Southampton and South West Hampshire Research Ethics Committee.


Z. Tan Y.H. Ng A. Yew C.L. Poh J. Koh B. Morrey H.T. Sen

Introduction

The epicondylar axis of the elbow is a surface anatomical approximation of the true flexion-extension (F-E) axis used in the application of an external fixator/elbow arthroplasty. We hypothesise that the epicondylar axis coincides with the true F-E axis in terms of both angular displacement and position (ie. offset). This suggests that it can serve as a good landmark in total dynamic external fixator application and elbow arthroplasty.

Methods

Three-dimensional elbow models were obtained through manual segmentation and reconstruction from 142±40 slices of CT scans per elbow in 15 cadeveric specimens. Epicondylar axis was defined to be the axis through the 2 epicondyles manually identified on the elbow models. F-E axis was defined to be the normal of a circle fitted on 20 points identified on the trochlear groove. The long axis of the elbow was identified through a line fit through the center of the distal humerus on several slices along the elbow CT. Angle between the long axis and epicondylar axis was measured. Angular deviation of the epicondylar axis and the F-E axis was calculated in reference to the long axis. All axes were projected onto the orthogonal planes on the elbow CTs and all measurements were repeated. Angular differences in the axial, saggital and coronal planes are described in internal/external rotation, flexion/extension and valgus/varus respectively. Offset in the axial and coronal planes are described in the following directions respectively: proximal/distal and anterior/posterior respectively. Comparisons between angles were performed using student's t-test.


T.M. Grupp B. Fritz I. Kutzner Georg Bergmann J. Schwiesau

Background

Wear simulation in total knee arthroplasty (TKA) is currently based on the most frequent activity – level walking. A decade ago multi-station knee wear simulators were introduced leading to optimisations of TKA designs, component surface finish and bearing materials. One major limitation is that current wear testing is mainly focused on abrasive-adhesive wear and in vitro testing does not reflect “delamination” as an essential clinical failure mode. The objective of our study was to use a highly demanding daily activities wear simulation to evaluate the delamination risk of polyethylene materials with and without vitamin E stabilisation.

Methods

A cruciate retaining fixed bearing TKA design (Columbus CR) with artificially aged polyethylene knee bearings (irradiation 30±2 kGy) blended with and without 0.1% vitamin E was used under medio-lateral load distribution and soft tissue restrain simulation. Daily patient activities with high flexion (2×40% stairs up and down, 10% level walking, 8% chair raising, 2% deep squatting) were applied for 5 million cycles. The specimens were evaluated for gravimetric wear and analysed for abrasive-adhesive and delamination wear modes.


T. Yasuda Y. Yokoi K. Oyanagi K. Hamamoto

Background

Non-contact anterior cruciate ligament (ACL) injuries occurs with a higher incidence in female athletes compared with males after the onset of puberty. One anatomical factor with clinically observable differences between males and females is lower extremity alignment. The knee joint valgus in the coronal plane, which is associated with ACL injury risk, is composed of rotation of the tibia around the stationary femur and hip rotation combined with knee flexion. The purpose of this study was to prove the difference of hip rotation between female and male handball players with or without history of ACL injury.

Methods

Elite collegiate athletes on the varsity handball team (17 females and 24 males) were recruited. Whereas 8 females and 1 male had a history of ACL injury, there were 9 females and 23 males with no history of ACL injury. The 6 measures of hip joint motion [flexion, extension, abduction, adduction, external rotation (ER), and internal rotation (IR)] and the 2 measures of knee joint motion (flexion and extension) were measured with the standard procedure using a goniometer.


A. Kuo C. Bahney L. Jacobs D. Hu H.T. Kim R. Marcucio

Background

Tissue engineering strategies to heal critical-size bone defects through direct bone formation are limited by incomplete integration of grafts with host bone and incomplete vascularisation. An alternative strategy is the use of cartilage grafts that undergo endochondral ossification. Endochondral cartilages stimulate angiogenesis and are remodeled into bone, but are naturally found in only small quantities. We sought to develop engineered endochondral cartilage grafts using human osteoarthritic (OA) articular chondrocytes.

Methods

Study approval was obtained from our human and animal ethics review committees. Human OA cartilage was obtained from discarded tissues from total knee replacements. Scaffold-free engineered grafts were generated by pelleting primary or passaged chondrocytes, followed by culture with transforming growth factor-β1 (TGF-β1) and bone morphogenetic protein 4. Samples were transplanted into immunocompromised mice either subcutaneously or into critical-size tibial defects. Grafts derived from passaged chondrocytes from either of two patients (64 year old and 68 year old men) where implanted into tibial defects in five mice. Bone formation was assessed with histology after four weeks of implantation.


T. Tanaka T. Furumatsu S. Miyazawa M. Fujii H. Inoue T. Ozaki

Background

Hyaluronan (HA) promotes extracellular matrix (ECM) production and inhibits the activity of matrix degrading enzymes in chondrocytes. The meniscus is composed of the avascular inner and vascular outer regions. Inner meniscus cells have a chondrocytic phenotype compared with outer meniscus cells. In this study, we examined the effect of HA on chondrocytic gene expression in human meniscus cells.

Methods

Human meniscus cells were prepared from macroscopically intact lateral meniscus. Inner and outer meniscus cells were obtained from the inner and outer halves of the meniscus. The proliferative activity of meniscus cells was evaluated by WST-1 assay in the presence or absence of HA (MW = 600–1200 kDa; Seikagaku). Gene expression of SOX9, COL2A1, and COL1A1 was assessed by a quantitative real-time PCR analysis. The effect of HA on the gene expression and cellular proliferation was investigated under the treatment of interleukin (IL)-1α. Meniscal samples perforated by a 2-mm-diameter punch were maintained for 3 weeks in HA-supplemented media. Cultured meniscal samples were evaluated by histological analyses.


U.T. Timur A. van der Windt M. Caron T.J. Welting P.J. Emans H. Jahr

Background

Treatment of cartilage defects requires in vitro expansion of human articular chondrocytes (HACs) for autologous chondrocyte implantation (ACI). During standard expansion culture (i.e. plasma osmolarity, 280 mOsm) chondrocytes inevitably lose their specific phenotype (i.e. collagen type II (COL2) expression). This de-differentiation makes them inappropriate for ACI. Physiological osmolarity (i.e. 380 mOsm) improves COL2 expression in vitro, but the underlying reason is unknown. However, an accepted key regulator of chondrocyte differentiation, transforming growth factor beta (TGFβ), is known to stimulate COL2 production. In this study we aimed to elucidate if TGFβ signaling could potentially be driving the COL2 expression under physiological culture conditions.

Material and methods

After informed consent was obtained, HACs were isolated from five osteoarthritis (OA) patients and cultured in cytokine-free medium of 280 or 380 mOsm, respectively, under standard 2D in vitro conditions with or without lentiviral TGFβ2 knockdown (RNAi). Expression of TGFβ isoforms, superfamily receptors and chondrocyte marker genes was evaluated by qRT-PCR, TGFβ2 protein secretion by ELISA and TGFβ bioactivity using luciferase reporter assays. Statistical significance was assessed by a student's t-test.


R. Beckmann A. Fragoulis M. Tingart T. Pufe C. Wruck H. Jahr

Background

Transcription factor nuclear factor E2p45-related factor 2 (Nrf2) is crucial for controlling the antioxidant response and maintaining cellular redox homeostasis. Binding of Nrf2 to antioxidant response elements (ARE) promotes the expression of anti-oxidative stress enzymes. In osteoblasts, Nrf2 directly interacts with Runx2, a strong transcriptional activator of osteoblast-specific genes. Sox9, a key regulator of chondrocyte differentiation is dominant over Runx2 in mesenchymal chondrogenic precursors. We therefore aimed to elucidate the role of Nrf2, and its regulation of Sox9, in chondrocytes.

Methods

ARE sites in SOX9 promoter fragments were inactivated and cloned into pGL3 prior to co-transfection with phRL-TK into C-28/I2 cells for dual luciferase assay (n=4). Analyses of Nrf2 and Sox9 expression (n=3), following Nrf2 RNA interference (RNAi) (Sigma-Mission shRNAs library), was performed by qPCR (Applied Biosystems) as well as by Nrf2 and Sox9 immunohistochemistry in femoral condyle cartilage of wild type (WT) and Nrf2-knockout (KO) mice with ethical approval.


A.C. Ramesh T.J. Levingstone R.T. Brady J.P. Gleeson P. Brama F.J. O'Brien

Background

Articular cartilage has poor repair properties and poses a significant challenge in orthopaedics. Damage as a result of disease or injury frequently leads to formation of an osteochondral defect. Conventional repair methods, including allograft, autograft and microfracture, have a number of disadvantages in terms of cost, associated technical challenges and the requirement for multiple operations. A novel tri-layered scaffold developed in our lab, addresses this issue as it closely matches the structure and composition of osteochondral tissue.

Methods

In vivo assessment was carried out in a caprine model by creating 6 mm × 6 mm defects in the medial femoral condyle and lateral trochlear ridge of each joint. Defects were implanted with the tri-layered scaffold and for comparison also with a market-leading scaffold, while some of defects were left empty, acting as a control. Assessment was carried out at 3 month, 6 month and 12 month time points. The quality of the repair at the various time points was graded macroscopically and microscopically by histological staining of the samples and also assessed using micro-CT (computed tomography) analysis.


F. Russo M. Musumeci F. De Strobel M. Bernardini G. De Benedictis L. Denaro D. D'Avella R. Giordano V. Denaro

Background

Stem cell based intervertebral disc (IVD) regeneration is quickly moving towards clinical applications. However, many aspects need to be investigated to routinely translate this therapy to clinical applications, in particular, the most efficient way to deliver cell to the IVD. Cells are commonly delivered to the IVD through the annulus fibrosus (AF) injection. However, recent studies have shown serious drawbacks of this approach. As an alternative we have described and tested a new surgical approach to the IVD via the endplate-pedicles (transpedicular approach). The Purpose of the study was to test MSCs/hydrogel transplantation for IVD regeneration in a grade IV preclinical model of IDD on large size animals via the transpeducular approach with cell dose escalation.

Methods

Adult sheep (n=18) underwent bone marrow aspiration for autologous MSC isolation and expansion. MSC were suspended in autologous PRP and conjugated with Hyaluronic Acid and Batroxobin at the time of transplant (MSCs/hydrogel). Nucleotomy was performed via the transpedicular approach in four lumbar IVDs and that were injected with 1) hydrogel, 2) Low doses of MSC/hydrogel, 3) High doses of MSC/hydrogel, 4) no injection (CTRL). The endplate tunnel was sealed using a polyurethane scaffold. X-ray and MRI were performed at baseline and 1,3,6,12 months. Disc macro- and micro-morphology were analysed at each time point.


P. Corrado P.A. Alan S.R. Michael

Background

As the number of ceramic THR bearings used worldwide is increasing, the number of implants that experience off-normal working conditions, e.g. edge loading, third bodies in the joint, soft tissues laxity, dislocation/subluxation of the joint, increases too. Under all such conditions the bearing surfaces can be damaged, leading eventually to a limitation of the expected performances of the implant.

Methods

We characterised the damage resistance of different bearing surfaces (alumina matrix composite BIOLOXdelta, alpha-alumina BIOLOXforte, zirconia 3Y-TZP, oxidized zirconium alloy Zr-2.5Nb, CoCr-alloy) by scratch tests performed following the European standard EN 1071–3:2005. Also the scratch hardness of same materials has been assessed.


M.F. Meijer A.L. Boerboom M. Stevens I.H.F. Reininga D.W. Janssen N. Verdonschot

Background

Trabecular metal (TM) cones are designed to fill up major bone defects in total knee arthroplasty. Tibial components can be implanted in combination with a stem, but it is unclear if this is necessary after reconstruction with a TM cone. Implanting a stem may give extra stability, but may also have negative side-effects. Aim of this study was to investigate stability and strain distribution of a tibial plateau reconstruction with a TM cone while the tibal component is implanted with and without a stem, and whether prosthetic stability was influenced by bone mineral density (BMD).

Methods

Tibial revision arthroplasties were performed after reconstruction of an AORI 2B bone defect with TM cones. Plateaus were implanted in seven pairs of cadaveric tibiae; of each pair, one was implanted with and the other without stem. All specimens were loaded to one bodyweight alternating between the medial and lateral tibia plateau. Implant-bone micro motions, bone strains, BMD and correlations were measured and/or calculated.


J. Callear K. Shah

Introduction

Despite recent national advances in the care for the hip fracture patient, significant morbidity and mortality persists. Some of this morbidity is attributable to the analgesia provided in the hospital setting. The National Institute of Clinical Excellence recommends the use of simple oral analgesia including opioids, with fascia-iliac blocks used as an adjunct. Literature review reveals a paucity of evidence on this topic. The aim of this study was to evaluate the efficacy of fascia iliac blocks through analysis of pre and post-operative opioid usage, post-operative delirium, time to bowel opening and naloxone use.

Methods

A retrospective study was performed between September-December 2013. Inclusion criteria were determined. 41 patients who received spinal anaesthesia alone and 41 patients who received spinal anaesthesia and a fascia-iliac block were included.


M.D. Jones M. Parry M. Whitehouse A.W. Blom

Background

Frequency of primary total hip (THA) and total knee (TKA) arthroplasty procedures is increasing, with a subsequent rise in revision procedures. This study aims to describe timing and excess surgical mortality associated with revision THA and TKA compared to those on the waiting list.

Methods

All patients from 2003–2013 in a single institution who underwent revision THA and TKA, or added to the waiting list for the same procedure were recorded. Mortality rates were calculated at cutoffs of 30- and 90-days post-operation or addition to the waiting list.


H. Lawrence D.J. Deehan J.P. Holland J.A. Kirby A.J. Tyson-Capper

Background

Metal-on-metal (MoM) hip arthroplasty has been associated with adverse reactions including pseudotumours, and osteolysis. Tissues surrounding failed MoM hip implants are often infiltrated by inflammatory cells such as monocytes and neutrophils. The mechanisms by which these cells are recruited to the tissues remain unclear. Cobalt from MoM implants activates Toll-like receptor 4 (TLR4), an immune cell surface receptor usually responsible for recognition of bacteria and prevention of sepsis. Activation by bacteria leads to secretion of pro-inflammatory cytokines which guide other immune cells to the site of inflammation. The effect of cobalt on this response is unknown and therefore this study aims to determine the effect of cobalt-mediated TLR4 activation on the migration of inflammatory cells.

Methods

A human macrophage cell line (MonoMac 6) was stimulated with a physiologically-relevant range of cobalt ions for 24h with or without pre-treatment with a TLR4 antagonist. Conditioned media was collected and used in a trans-well migration assay to determine its effect on migration of primary monocytes and neutrophils isolated from whole human blood. Migrated cells were stained with haematoxylin and counted at ×40 magnification.


D. Janssen T. Bitter B.W. Schreurs T. Marriott I. Khan N. Verdonschot

Background

Fretting at modular junctions is thought to be a ‘mechanically assisted’ corrosion phenomenon, initiated by mechanical factors that lead to increased contact stresses and micromotions at the taper interface. We adopted a finite element approach to model the head-taper junction, to analyse the contact mechanics at the taper interface. We investigated the effect of assembly force and angle on contact pressures and micromotions, during loads commonly used to test hip implants, to demonstrate the importance of a good assembly during surgery.

Methods

Models of the Bimetric taper and adaptor were created, with elastic-plastic material properties based on material tests with the actual implant alloy. FE contact conditions were validated against push-on and pull-off experiments. The models were loaded according to ISO 7206-4 and −6, after being assembled at 2-4-15kN, both axially and at a 30° angle. Average micromotions and contact pressures were analysed, and a wear score was calculated based on the contact pressures and micromotions.


M.A.E. Schoeman A.E. Oostlander K.E. de Rooij C.W.G.M. Löwik E.R. Valstar R.G.H.H. Nelissen

Background

Aseptic loosening of prostheses is the most common cause for failure in total joint arthroplasty. Particulate wear debris induces a non-stop inflammatory-like response resulting in the formation of a layer of fibrous periprosthetic tissue at the bone/implant interface. The current treatment is an invasive revision joint replacement surgery. However, this procedure has a high morbidity rate, therefore, a less invasive alternative is necessary. One approach could be to re-establish osseointegration of the joint prosthesis by inducing osteoblast differentiation in the periprosthetic tissue. Therefore, the aim of this study was to investigate the capacity of periprosthetic tissue cells to differentiate into the osteoblast lineage.

Methods

Periprosthetic tissue samples were collected during revision surgery of aseptic loosened hip prostheses, after which cells were isolated by collagenase digestion. Of 14 different donors, cells from passage 1 till 3 were used for differentiation experiments. During 21 days, cells were cultured under normal and several osteogenic culture conditions. Cultures were stained for alkaline phosphatase (ALP) activity and mineral deposits in the extracellular matrix.


L. Li A. Patel H. Jundi H. Parmar

Background

Focal resurfacing can treat localised articular damage of the knee not appropriate for arthroplasty or biological repair. Independent results on these implants are limited. We previously published early results showing significantly improved Knee Injury & Osteoarthritis Outcome Score (KOOS4) without complication or re-operation, demonstrating this system gives good analgesia and functional improvement in selected patients. We present long-term follow-up of these patients.

Methods

We prospectively evaluated medium- to long-term results in patients with localised, full-thickness articular cartilage defects of the knee undergoing HemiCAP resurfacing. All procedures were performed by one consultant surgeon. Post-operative rehabilitation was standardised. Outcome measures were KOOS4 score, visual analogue score (VAS), Kellgren and Lawrence arthritis grade, and re-operation rates.


T.S. Adesina S. Ajami M.J. Coathup G.W. Blunn

Background

Stress shielding and wear induced aseptic loosening cause failure in arthroplasty surgery. To improve survivorship, the use of a low modulus, low wearing biomaterial may be a suitable alternative to hard bearing prostheses, such as cobalt chromium (CoCr). There has been considerable research interest in the use of polyetheretherketone (PEEK) based on observed clinical success especially in spinal surgery. This study investigated the wear performance of PEEK, carbon reinforced PEEK (CFR-PEEK) and acetal as bearing materials in an all polymer total knee arthroplasty (TKA) using a unidirectional pin on plate test.

Methods

The following material combinations were tested: PEEK vs. UHMWPE, CFR-PEEK vs. UHMWPE, PEEK vs. PEEK, CFR-PEEK vs. PEEK, CoCr vs. UHMWPE, PEEK vs. XLPE, CFR-PEEK vs. CFR-PEEK, PEEK vs. Acetal, Acetal vs. XLPE and CoCr vs. XLPE.Tribological couples tested (Pin vs. Plate) Using a previously validated modification of ASTM F732, 20mm diameter spherically ended pins with a radius of 25mm were articulated against 40mm diameter plates. A load of 1000N was applied to generate a contact stress of about 70MPa similar to contact stresses previously reported in the knee. The lubricant used was 25% newborn calf serum containing 0.3% sodium azide to retard bacteria growth and 20mM EDTA to prevent calcium deposition. Three repeats of pin on plate combinations (including 2 passive soak controls) were tested for 2 million cycles at a cycle frequency of 1Hz and a stroke length of 10 mm. Gravimetric wear was analysed every 250,000 cycles and results converted to volumetric wear using material density.


B.R. Rastetter S.J. Wright S. Gheduzzi A.W. Miles S.E. Clift

Background

Finite element (FE) models are frequently used in biomechanics to predict the behaviour of new implant designs. To increase the stability after severe bone loss tibial components with long stems are used in revision total knee replacements (TKR). A clinically reported complication after revision surgery is the occurrence of pain in the stem-end region. The aim of this analysis was the development of a validated FE-model of a fully cemented implant and to evaluate the effect of different tibial stem orientations.

Methods

A scanned 4th generation synthetic left tibia (Sawbones) was used to develop the FE-model with a virtually implanted fully cemented tibial component. The 500 N load was applied with medial:lateral compartment distributions of 60:40 and 80:20. Different stem positons were simulated by modifying the resection surface angle posterior to the tibias shaft axis. The results were compared with an experimental study which used strain gauges on Sawbones tibias with an implanted tibial TKR component. The locations of the experimental strain gauges were modelled in the FE study.


M. Verstraete S. Van Onsem C. Stevens S. Herregodts N. Arnout J. Victor

Background

In-vitro testing of knee joints remains vital in the understanding of knee surgery and arthroplasty. However, based on the design philosophy of the original Oxford knee simulator, this in-vitro testing has mainly focused on squatting motion. As the activities of daily living might drastically differ from this type of motion, both from a kinematic and kinetic point of view, a new knee simulator is required that allows studying more random motion patterns. This paper describes a novel knee simulator that overcomes the limitations of traditional Oxford simulators, providing both kinematic and kinetic freedom with respect to the applied boundary conditions.

Methods

This novel test simulator keeps the hip at a fixed position, only providing a single rotational degree of freedom (DOF) in the sagittal plane. In addition, the ankle holds four DOF, including all rotational DOF and the translation along the medio-lateral axis. Combining these boundary conditions leaves five independent DOF to the knee; the knee flexion angle is actively controlled through the positioning of the ankle joint in the antero-posterior and proximal-distal direction. The specimens' quadriceps muscle is actively controlled, the medial and lateral hamstrings are passively loaded. To validate the performance of this simulator, two fresh frozen specimens have been tested during normal squatting and cycling. Their kinematic patterns have been compared to relevant literature data.


N. Islam M. Whitehouse S. Mehandale A. Blom G. Bannister R. Ceredig B. Bradley

Background

Post-traumatic immunosuppression (PTI) after surgery increases vulnerability to nosocomial infections, sepsis, and death. Knee arthroplasty offers a sterile clinical model to characterise PTI and explore its underlying mechanisms.

Methods

This prospective non-randomised cohort study of primary total knee arthroplasty was approved by the Local Ethics Committee. Exclusion criteria included revision-arthroplasty, pre-existing infections, blood-transfusions, malignancy, and auto-immune disease. 48 recruited patients fell into two groups, the first received unwashed anti-coagulated autologous salvaged blood transfusions after surgery (ASBT cohort, n=25). The second received no salvaged blood transfusions (NSBT cohort, n=18). Venous blood was sampled pre-operatively and within 3–7 days post-operatively. Salvaged blood was sampled at one and six hours post-operatively. Biomarkers of immune status included: interleukins (IL) or cytokines (x15), chemokines (x3), Damage-Associated-Molecular-Patterns (DAMPS) (x5), anti-microbial proteins (x3), CD24, and Sialic-acid-binding-Immunoglobulin-type-Lectin-10 (Siglec-10). Results were expressed as fold-change over pre-operative values. Only significant changes are described.


M.F. Meijer A.L. Boerboom S.K. Bulstra I.H.F. Reininga M. Stevens

Background

Achieving optimal prosthesis alignment during total knee arthroplasty (TKA) is essential. Imageless computer-assisted surgery (CAS) is developed to improve knee prosthesis alignment and with CAS it is possible to perform intraoperative alignment measurements. Lower limb alignment measurements are also performed for preoperative planning and postoperative evaluation. A new stereoradiography system, called EOS, can be used to perform these measurements in 3D and thus measurement errors due to malpositioning can be eliminated. Since both CAS and EOS are based on 3D modeling, measurements should theoretically correlate well. Therefore, objective was to compare intraoperative CAS-TKA measurements with pre- and postoperative EOS 3D measurements.

Methods

In a prospective study 56 CAS-TKAs were performed and alignment measurements were recorded two times: before bone cuts were made and after implantation of the prosthesis. Pre- and postoperative coronal alignment measurements were performed using EOS 3D. CAS measurements were compared with EOS 3D reconstructions. Measured angles were: varus/valgus (VV), mechanical lateral distal-femoral (mLDFA) and medial proximal tibial angle (mMPTA).


R. Kabariti M. Whitehouse

Background

Recent studies have suggested that full-limb radiographs are more accurate and sensitive than short film radiographs for pre-operative measurement of the anatomical angles required to achieve optimal knee alignment in Total Knee Arthroplasty (TKA). However, there are drawbacks associated with their use including excess radiation to the pelvic organs, the need for specialised radiography equipment and increased cost. Given these drawbacks, we compared the use of MRI scans, a commonly performed pre-operative investigation, with short film knee radiographs for measurement of knee alignment.

Objective

To investigate whether knee alignment measurements made on MRI scans correlate with those measured on short film knee radiographs in patients with osteoarthritic knees.


T. Barlow D. Griffin P. Scott A. Realpe

Background

Knee replacement surgery is currently facing three dilemmas: a high dissatisfaction rate; increasing demand with financial constraints; and variation in utilisation. A patient centred approach, usually achieved through shared decision-making, has the potential to help address these dilemmas. However, such an approach requires an understanding of the factors involved in patient decision-making. This is the first study examining decision-making in knee replacements that includes patients at different stages of decision-making – this is critical when considering decision-making as a process. We base our findings in a theoretical model, proposed by Elwyn et al, that highlights the distinction between deliberation and decision-making, and propose modifications to this model specific to knee replacement decision-making.

Methods

This study used two focus groups of six patients each and in-depth interviews with 10 patients to examine the factors that affect patient decision-making and their interaction at different points in the decision-making process. A qualitative analysis of themes, based on a constant comparative method, is used to analyse the data. This study was approved by the Dyfed Powys Research Ethics Committee (13/WA/0140).


M. Hadi T. Barlow I. Ahmed M. Dunbar D. Griffin

Background

Total Knee Replacement (TKR) is an effective treatment for knee arthritis. One long held principle of TKRs is positioning the components in alignment with the mechanical axis to restore the overall limb alignment to 180 ± 3 degrees. However, this view has been challenged recently. Given the high number of replacements performed, clarity on this integral aspect is necessary. Our objective was to investigate the association between malalignment and outcome (both PROMs and revision) following primary TKR.

Metod

A systematic review of MEDLINE, CINHAL, and EMBASE was carried out to identify studies published from 2000 onwards. The study protocol including search strategy can be found on the PROSPERO database for systematic reviews.


G. Ciapetti C. Fotia D. Granchi M. Rojewski P. Rosset E. Gómez-Barrena N. Baldini

Background

Delayed bone healing and nonunion are complications of long bone fractures, with prolonged pain and disability. Regenerative therapies employing mesenchymal stromal cells (MSC) and/or bone substitutes are increasingly applied to enhance bone consolidation. Within the REBORNE project, a multi-center orthopaedic clinical trial was focused on the evaluation of efficacy of expanded autologous bone marrow (BM) derived MSC combined with a CaP-biomaterial to enhance bone healing in patients with nonunion of diaphyseal fractures. To complement the clinical and radiological examination of patients, bone turnover markers (BTM) were assayed as potential predictors of bone healing or non-union.

Methods

Bone-specific alkaline phosphatase (BAP), C-terminal-propeptide type I-procollagen (PICP), osteocalcin (OC), β-Cross-Laps Collagen (CTX), soluble receptor activator of NFkB (RANKL), osteoprotegerin (OPG) were measured by ELISA assays in blood samples of 22 patients at BM collection and at follow-ups (6, 12 and 24 weeks post-surgery).


S. Ray U. Thormann U. Sommer T. ElKhassawna M. Rhonke A. Henns M. Gelinsky T. Hanke R. Schnettler C. Heiss V. Alt

Background

Multiple Myeloma is a hematological malignancy of terminally differentiated plasma cells associated with increased osteoclast activity and decreased osteoblast functions. Systemic antiproliferative treatment includes proteasome inhibitors such as bortezomib, a clinical potent antimyeloma agent. Local delivery of biological active molecules via biomaterial composite implants to the site of the lesion has been shown to be beneficial for bone and implant-associated infections. In anticancer treatment local delivery of anticancer agents to the neoplasia via biomaterial carriers has never been reported before. The purpose of the current is to present the concepts and the first in vivo results for proteasome inhibitor composite biomaterials for local delivery of bortezomib to proliferative multiple myeloma bone lesions including concentration measurements at different anatomical regions in a rat model.

Methods

80 female Sprague-Dawley rats were randomised into five different treatment groups (n=16/group): 1) Empty (2) Xerogel-granulat: XG (3) Xerogel-granulat+100mgbortezomib [b]: XG100b (4) Xerogel-granulat+500mgb:XG500b (5) Xerogel-granulat+2500mgb:XG2500b. A 2.5 mm drill hole was then created in the metaphysis of the left femur. The defect was then either filled with the previously mentioned substitutes or left empty to serve as a control. After 4 weeks femora were harvested followed by histological, histomorphometrical and immunohistochemical (BMP2; bone-morphogenic protein 2, OPG; osteoprotegerin, RANKL; Receptor activator of nuclear factor kappa-B ligand, ASMA; alpha smooth muscle actin, ED1;CD68 antibody). TOF-SIMS was used to assess the distribution of released strontium ions. Statistical analysis was done using SPSS software. Data was not found normally distributed and hence Mann-Whitney U with bonferroni correction was used. To avoid type I errors due to unequal variances and group sizes Games-Howell test was also performed.


A. Sanghani M. Coathup S. Samazideh P. Kalia L. Di Silvio G. Blunn

Background

Osteoporosis and bone fractures lead to immobility, chronic pain and high patient care costs. Mesenchymal stem cells (MSCs) from postmenopausal women have a slower growth rate and osteogenic differentiation ability causing lower bone density and reduced fracture healing capacity compared to MSCs from premenopausal women. Cellular movement and relocalisation are necessary for many physiologic properties. Local MSCs from injured tissues and circulating MSCs are involved in fracture healing. Cytokines and chemokines such as SDF-1 and its receptor CXCR4 play important roles in maintaining mobilisation, trafficking and homing of stem cells from bone marrow to the site of injury. This study investigated the effect of CXCR4 over-expression on the migration of MSCs from ovariectomised, normal and young rats.

Methods

MSCs were harvested from femora of young, normal and OVX rats, genetically modified to over-express CXCR4and put in a Boyden chamber to establish their migration towards SDF-1. This was compared to the non-transfected stem cells.


S. Ray T. El Khassawna U. Thormann U. Sommer M. Rhonke A Henns M. Gelinsky T Hanke R. Schnettler C. Heiss V. Alt

Objectives

Osteoporosis and osteomalacia lead to increased fracture risk. Previous studies documented dysregulated osteoblast and osteoclast activity, leading to a high-turnover phenotype, reduced bone mass and low bone mineral content. Osteocytes, the most abundant bone cell type, are involved in bone metabolism by enabling cell to cell interaction. Osteocytes presence and viability are crucial for bone tissue homeostasis and mechanical integrity. Osseo-integration and implant degradation are the main problems in developing biomaterials for systemically diseased bone. This study examines osteocyte localisation, morphology and on the implant surface and at the implant bone interface. Furthermore, the study investigates ECM proteins regulation correlated to osteocytes and mechanical competence in an ovariectomised rat model with a critical size metaphyseal defect.

Methodology

After induction of osteoporosis, 60 female Sprague-Dawley rats were randomised into five groups: SrCPC (n=15), CPC (n=15), ScB30 (n=15), ScB30Sr20 (n=15) and empty defect (n=15). The left femur of all animals underwent a 4mm wedge-shaped metaphyseal osteotomy that was internally fixed with a T-shaped plate. The defect was then either filled with the above mentioned implants or left empty. After six weeks, histomorphometric analysis showed a statistically significant increase in bone formation at the tissue-implant interface in the SrCPC group compared to the other groups (p<0.01). Osteocyte morphology and networks were detected using silver and staining. ECM proteins were investigated through immunohistochemistry. Cellular populations were tested using enzyme histochemistry. Mineralisation was assessed using time of flight secondary ion mass spectrometry (TOF-SIMS). Statistical analysis was performed using Mann Whitney U test with Bonferroni correction.


E. Gomez-Barrena P. Rosset P. Hernigou F. Gebhard C. Ehrnthaller N. Baldini P. Layrolle

Background

Definitive proof is lacking on mesenchymal stem cell (MSCs) cellular therapy to regenerate bone if biological potential is insufficient. High number of MSCs after GMP expansion may solve the progenitor insufficiency at the injury but clinical trials are pending.

Methods

A prospective, multicenter, multinational Phase I/IIa interventional clinical trial was designed under the EU-FP7 REBORNE Project to evaluate safety and early efficacy of autologous expanded MSCs loaded on biomaterial at the fracture site in diaphyseal and/or metaphysodiaphyseal fractures (femur, tibia, humerus) nonunions. The trial included 30 recruited patients among 5 European centres in France, Spain, Germany, and Italy. Safety endpoints (local and general complication rate) and secondary endpoints for early efficacy (number of patients with clinically and radiologically proven bone healing at 12 and 24 weeks) were established. Cultured MSCs from autologous bone marrow, expanded under GMP protocol was the Investigational Medicinal Product, standardised in the participating countries confirming equivalent cell production in all the contributing GMP facilities. Cells were mixed with CE-marked biphasic calcium phosphate biomaterial in the surgical setting, at an implanted dose of 20−106 cells per cc of biomaterial (total 10cc per case) in a single administration, after debridement of the nonunion.


S. Vidal Rodríguez I. del Castillo

Background

Rotator cuff disease (RCD) is the most common cause of shoulder pain and limitation of activities in sports and in repetitive work. The aetiology of RCD is not well established. A number of gene pathways are altered in RCD. Polymorphisms in Col1A1, Col5A1 (encoding collagen) and GDF5 (TGF-beta superfamily) can be associated with RCD susceptibility.

Materials and Methods

Single-nucleotide polymorphisms (SNPs) in Col1A1, GDF5 and Col5A1 were genotyped in a case-control study with 103 RCD patients and 104 controls in Caucasian and African populations who suffered from injuries in any other anatomical location. All patients provided signed informed consent. Sampling was carried out with a puncture of the pad of a finger using a sterile, single-use lancet. NSPs were determined by real-time polymerase chain reaction (PCR) using specific, unique probes with the analysis of the melting temperature of hybrids. The X2 test compared genotypes between groups. Multivariate logistic regression analysed the significance of many covariates and the incidence of RCD.


O. Dolkart H. Yehuda Y. Zarfati T. Brosh O. Chechik E. Maman

Background

The effect of corticosteroids on tendon properties is poorly understood, and current data are insufficient and conflicting. The objective of this study was to evaluate the effects of corticosteroids injection on intact and injured rotator cuff (RC) through biomechanical and radiographic analyses in a rat model.

Methods

70 rats were assigned to seven groups:1)control - saline injection;2) no tear + single methylprednisolone acetate (MTA) injection; 3) no tear + triple MTA injection; 4) tear + single saline injection; 5) tear + single MTA injection; 6) tear+ triple saline injections; 7) tear+ triple MTA injections. Triple injections were repeated once a week. Following unilateral supraspinatus (SSP) injuries, MTA was injected subacromialy. Rats were sacrificed 1 week after last injection. Shoulders were harvested, grossly inspected, SSP was evaluated biomechanically. Bone density at the tendon insertion site on the greater tuberosity (GT) were assessed with micro-computed tomography (CT).


T. Thangarajah C.J. Pendegrass S. Shahbazi S. Lambert S. Alexander G.W. Blunn

Background

Re-attachment of tendon to bone is challenging with surgical repair failing in up to 90% of cases. Poor biological healing is common and characterised by the formation of weak scar tissue. Previous work has demonstrated that decellularised allogenic demineralised bone matrix (DBM) regenerates a physiologic enthesis. Xenografts offer a more cost-effective option but concerns over their immunogenicity have been raised. We hypothesised that augmentation of a healing tendon-bone interface with DBM incorporated with autologous mesenchymal stem cells (MSCs) would result in improved function, and restoration of the native enthesis, with no difference between xenogenic and allogenic scaffolds.

Methods

Using an ovine model of tendon-bone retraction the patellar tendon was detached and a complete distal tendon defect measuring 1 cm was created. Suture anchors were used to reattach the shortened tendon and xenogenic DBM + MSCs (n=5) and allogenic DBM + MSCs (n=5) were used to bridge the defect. Functional recovery was assessed every 3 weeks and DBM incorporation into the tendon and its effect on enthesis regeneration was measured using histomorphometry.


J.J. Arts J. Hazrati Marangalou G. Meijer K. Ito B. van Rietbergen J.J. Homminga

Background

Finite element (FE) models have become a standard pre-clinical tool to study biomechanics of spine and are used to simulate and evaluate different strategies in scoliosis treatment: examine their efficacy as well as the effect of different implant design parameters. The goal of this study is to investigate, in a system of rods and laminar wires, the effect of the number of wires and their pre-stress on whole spine stiffness.

Methods

A generic FE model was developed to represent a full human spine, including vertebrae, intervertebral discs, ligaments, facet and costovertebral joints, and ribcage. Intervertebral discs were modeled with 3D rebar elements with linear elastic material properties. Vertebrae, ribs, sternum, facet joints, cartilage and endplates were modeled with brick elements, and costal muscles with shell elements with linear elastic properties. Furthermore, ligaments were modeled with truss elements with nonlinear hypo-elastic properties. The spine model was instrumented from T7 to T12 with rods and wires modeled as titanium. Nonlinear contact properties were defined for rib neck-vertebra, transverse processes-rib and facet joint sets. The FE model was loaded in flexion and the whole spine instantaneous stiffness was calculated for different wire pre-stressing levels (0.1 to 2 MPa). Similar analyses were performed with changed numbers of wires and whole spine stiffness was calculated.


A. Moore R. Gooberman-Hill

Background

Around 1% of patients who have hip replacement have deep prosthetic joint infection afterwards. Infection is treated with antibiotics and revision surgery. We aimed to characterise the impact of deep joint infection and its treatment, to identify treatment preferences, and to describe surgeons' treatment decisions.

Methods

In a qualitative study in the UK we interviewed 19 patients who had infection after hip replacement and 12 orthopaedic surgeons specialising in infection. Face-to-face interviews with patients explored experience of infection, treatment and recovery. Interviews with surgeons explored treatment decisions. With consent, interviews were audio-recorded, transcribed and anonymised. Once imported into QSR NVivo software, data were analysed using constant comparison.


A. Sayers V. Wylde E. Lenguerrand A. Beswick R. Gooberman-Hill M. Pyke P Dieppe A.W. Blom

Objective

There is limited information about the extent to which the association between pre-operative and chronic post-operative pain is mediated via pain-on-movement or pain-at-rest. We explored these associations in patients undergoing total hip (THR) and total knee (TKR) replacement.

Methods

322 and 316 patients receiving THR and TKR respectively were recruited into in a single centre UK cohort (APEX) study. Pre-operative, acute post-operative and 12-month pain severity was measured using self-reported pain instruments. The association between pre-operative / acute pain and chronic post-operative pain was investigated using structural equation modelling (SEM).


H. Floyd J. Lord E. Davies O. Addison L Grover

Background

Investigations into the response to implant debris tend to concentrate on how a population of cells proliferate in the presence of implant material, and how the regulation of cytokines change. For the problem of cobalt-chromium (CoCr) implants this has been done for osteoblasts and osteoclasts to understand how bone resorption, leading to aseptic loosening, is occurring. However, investigating the formation of the extracellular-matrix (ECM) may give a better indication of the mechanisms occurring. ECM is excreted from cells and is important for adhesion, structure, signaling and growth. Type I collagen is the most abundant protein in the ECM and is known to direct tissue development and is therefore a key part of understanding the mechanism behind aseptic loosening.

Methods

3T3-fibroblasts were seeded in Dulbecco's Modified Eagle Medium (DMEM) and supplemented with 100mM ascorbic acid. Every 48hours cells were fed with DMEM and doped with Co and Cr ions until fixation. Sirius Red dye was used to bind to the type I collagen, then removed using NaOH and analysed using UV absorption to show relative amounts of collagen. Type I collagen gel was formed in the presence of Co and Cr ions with and without DMEM and the fibers were imaged using AFM.


J. Jelsma R. Senden M. Schotanus N. Kort B. Grimm I. Heyligers

Background

The second generation metal-on-metal (MoM) prosthesis of the hip became a worldwide success in the 90s. However, after the placement of a MoM prosthesis the cobalt ion concentrations raise significantly. This may lead to systemic complaints and even cobalt toxicity.

Methods

Sixty-one patients (26F/35M) with both an unilateral and bilateral resurfacing or large-head MoM (LHMoM) hip prosthesis were included. At last follow-up (5.77 ± 1.57 yrs) cobalt concentrations in the blood were determined by ICP-MS. Based on the known cobalt toxicity symptoms we developed a non-validated questionnaire. Analysis was done on two groups; a low cobalt concentration group and a high cobalt concentration group. We used 170 nmol/L as the upper limit of well functioning prosthesis as defined by the Dutch Orthopaedic Society (NOV). Independent samples T test and Pearson correlation coefficient were done.


A. Karakaşlı M.H. Özcanhan A. Karaaslan R. Özmanevra F. Ertem D.V. Yıldız

Background

Femur fracture fixation systems depend on the stability of the supporting cortical screws, inside the host bone. Only a few works have studied the stability of cortical screws in femur shafts and compared their results with previous studies.

Methods

In present study, five different cortical screw types are assessed using artificial femurs, under equated testing conditions. The maximum force needed to cause screw-bone inter face failure was measured, for each screw type by pullout tests. The obtained results were normalised according to traditional methods and cross-compared. The best performer was searched for and the effect of screw dimensions on the screw performance was investigated. To make the pullout tests solely dependent on screw dimensions, the effect of the bicortical bone thickness was eliminated by equating the conditions of screw insertion.


O.O. Lancaster-Jones M. Al-Hajjar J. Thompson G. Isaac J. Fisher

Background

Many factors contribute to the occurrence of edge-loading conditions in hip replacement; soft tissue tension, surgical position, patient biomechanical variations and type of activities, hip design, etc. The aim of this study was to determine the effect of different levels of rotational and translational surgical positioning of hip replacement bearings on the occurrence and severity of edge-loading and the resultant wear rates.

Method

The Leeds II Hip-Joint Simulator and 36mm diameter alumina matrix composite ceramic bearings (BIOLOX delta, DePuy Synthes, UK) were used in this study. Different levels of mismatch between the reconstructed rotational centres of the head and the cup were considered (2, 3 and 4mm) in the medial-lateral axis. Two cup inclination angles were investigated; an equivalent to 45 and 65 degrees in-vivo, thus six conditions (n=6 for each condition) were studied in total with three million cycles completed for each condition. The wear of the ceramic-on-ceramic bearings were determined using a microbalance (Mettler Toledo, XP205, UK) and the dynamic microseparation displacement was measured using a Liner Variable Differential Transformer.


M.K. Wasko K. Bobecka Wesolowska I. Pokrzywnicka G. Kowalczewski J. Kowalczewski

Background

Hitherto, no study has compared blood loss (BL) after different thromoprophylactic regimes (TR). The objective of this study was to quantify and compare BL in total hip arthroplasty (THA) under three different TRs.

Methods

Between September 2013 and July 2014, sixty primary, unilateral, same-implant THAs entered a randomised, double-blind clinical trial. The patients were randomised to receive manufacturers' recommended doses of enoxaparin, dabigatran or rivaroxaban. Complete blood counts were obtained preoperatively and on the third day postoperatively. BL was calculated according to the Nadler formula. We also evaluated the occurence of wound healing disturbances (WHDs). All data were analysed using R statistical software.


S.J. Wong J. Nicholson I. Ahmed A. Ning J.F. Keating

Background

Acetabular fractures occur as a result of high-velocity trauma and are often associated with other life threatening injuries. Approximately one-third of these fractures are associated with dislocation of the femoral head but there are only few studies documenting the long term outcomes of this group of acetabular fracture.

Methods

This was undertaken at the Royal Infirmary of Edinburgh which provides the definitive orthopaedic treatment for all major trauma including all acetabular fractures for the South East of Scotland. We retrospectively reviewed patients who sustained an acetabular fracture associated with a posterior hip dislocation from a prospectively gathered trauma database between 1990 to 2010. Patient characteristics, complications and the requirement for further surgery were recorded. Patient outcomes were measured using the Oxford Hip score and Short Form SF-12 health survey.


D. Cundall-Curry J.E. Lawrence

Background

Since it's establishment in 2007, the National Hip Fracture Database [NHFD] has been the key driving force in improving care for hip fracture patients across the UK. It has facilitated the setting of standards to which all musculoskeletal units are held, and guides service development to optimise outcomes in this group of patients. As with any audit, the ability to draw conclusions and make recommendations for changes in practise relies on the accuracy of data collection. This project aimed to scrutinise the data submitted to the NHFD from a Major Trauma Centre [MTC], focusing on procedure coding, and discuss the implications of any inaccuracies.

Method

The authors performed a retrospective analysis of all procedure coding data entered into the NHFD from July 2009 to July 2014 at Cambridge University Hospitals NHS Foundation Trust. We examined 1978 cases for discrepancies, comparing procedure codes entered into the NHFD with post-procedure imaging and operative notes.


A. Goubran S. McHale C.W.B. Steinlechner

Background

Aseptic loosening of cemented femoral stems results from migration of wear particles along the bone-cement interface, producing a foreign body reaction. After cement insertion, blood back pressure can disrupt the bone-cement interface, enabling this spread of wear particles. Our study investigates whether altering timing and speed of stem insertion can reduce this risk.

Methods

We inserted mock “C-Stem” femoral components (De Puy-Synthes), using Smartset HV cement (De Puy-Synthes) into artificial femora, fitted with proximal and distal pressure transducers. Cement insertion began two, three or four minutes after mixing. Cement pressures were then allowed to settle for one minute and the stems were then inserted over durations of 25, 60 or 90 seconds.


V.M.A. Voorn P.J. Marang- van de Mheen A. van der Hout T.P.M. Vliet Vlieland R.G.H.H. Nelissen L. van Bodegom

Backgroud: Allogeneic transfusion rates after primary hip and knee arthroplasty are used as quality indicators for hospitals, but hospital comparisons may be hampered by low event rates. Extended hospital stay is often used and may be more suitable as an alternative. This study aims to assess whether transfusion rates and extended hospital stay can be used to reliably rank hospitals.

Methods

We used the baseline data from the LISBOA implementation trial, where data on patient characteristics and outcomes were collected in a sample of approximately 100 patients undergoing elective primary total hip or knee arthroplasty for each of the 23 participating hospitals. We calculated the reliability of ranking (Rankability) of transfusion rates and extended hospital stay (> 4 postoperative days), using fixed and random effects logistic regression analysis, by dividing the between-hospital variation to the sum of within and between-hospital variation. Rankability thus shows which part of the hospital differences are true differences and not due to random variation.

Results

1163 total hip and 986 total knee procedures were assessed. After adjustment for patient characteristics the odds ratio (OR) of receiving a transfusion in a hospital after total hip ranged from 0.72 to 1.38 and from 0.30 to 3.30 in total knee. Rankability was 17% for hip and 36% for knee arthroplasty, meaning that only 17% and 36% are true hospital differences. Larger hospital variation was found for extended hospital stay (OR range [0.28–3.51] for hip and [0.10–9.95] for knee arthroplasty), and better rankability.


S.P. Singh I. Parviaine M. Hyvärinen H. Dekker C.H. Ten Bruggenkate J. Mikkonen E. Schulten N. Bravenboer A. Koistinen A. Kullaa

Background

Radiotherapy has contributed with a significant and impressive stride to the survival rates of oral cancer patients. However, quality and alterations in the biochemical composition of bones used for dental implantation after radiotherapy in cancer patients is always a critical and debatable factor. The aim of this study was to determine compositional alterations in human mandible bone after irradiation using Raman microspectroscopy.

Methods

A total of 36 bone biopsies (21-control, 4-cancer and 11-irradiated) obtained from 36 patients during implant surgery were used. Raman measurements were carried out using a Bruker Senterra LX200 dispersive Raman spectrometer. Data acquisition points were determined under pathological supervision. Three measurements from different locations were conducted with a spot size of 10 microns. Spectra were acquired for 60s and averaged over 5-accumulations. Both mineral and matrix constituents were analysed by computing area associated with of phosphate (958 cm-1), carbonate (1070 cm-1), collagen (amide III) and matrix (amide I) bands using in-house MATLAB-based software. Unpaired student ‘t’ test was employed to measure level of significance.


C.J.C. Gouk P. Rebgetz M.J. Thomas

Background

Distal radius fractures are among the most common fractures encountered in the clinical setting, with a reported incidence of 17%. Of these common fractures, it has been said 60% are intra-articular in nature. Intra-articular or unstable and comminuted fractures represent severe, high energy injuries. There is a considerable amount of controversy as to which fixation method is superior. Even the OA concludes; “comparing external fixation (EF) with open reduction and internal fixation (ORIF) for the treatment of intra-articular distal radius fractures described no consistent benefit of one treatment over another”. There are only a few randomised control trials that go beyond one year to cover the long-term follow up (over two years). There has yet to be a meta-analysis of the long-term outcomes of open reduction internal fixation (ORIF) versus external fixation. We aim to show from this meta-analysis if there is any significant difference in the outcomes of either fixation method in the long-term.

Method

We pooled the data of all available randomised control trials that compare the long-term outcomes of ORIF against external fixation of distal radius fractures. We completed a systematic review of PubMed, embase, MEDLINE and the Cochrane Library, from inception to December 2014. We then preformed our meta-analysis using RevMan 5.3 software.


M. Aragonés E. Hevia A. Caballero C. Barrios

Background

The controversy concerning the benefits of unisegmental cervical disc arthroplasty (CDA) over anterior cervical discectomy and fusion (ACDF) is still open because some randomised clinical trial (RTC) comparing ACDF with CDA have been highly inconclusive. Most of these studies mixed disc prosthesis with dissimilar kinematic characteristics. To date, a compilation of the clinical and radiologic outcomes and adverse events of anterior cervical discectomy and fusion (ACDF) compared with a single cervical disc arthroplasty (CDA) design, the Bryan disc has partially accomplished.

Methods

This is a systematic review of RCTs with level I-II evidence. Only RCTs reporting clinical outcomes were included in this review. After a search on different databases including PubMed, Cochrane Central Register of Controlled Trials, and Ovid MEDLINE, a total of 10 RCTs out of total 51 studies were entered in the study. RTC's were searched from the earliest available records in 2005 to December 2014.


R. Lorente L. Fernández-Pineda J. Burgos L.M. Antón-Rodrigálvarez E. Hevia C. Pérez-Encinas C. Barrios

Background

After surgical correction of thoracic scoliosis, an improvement in the cardio-respiratory adaptation to exercise would be expected because of the correction of the rib cage associated with the spinal deformity. This work intended to evaluate the physiologic responses to incremental exercise in patients undergoing surgical correction of adolescent idiopathic scoliosis (AIS). The hypothesis of this study was that the exercise limitations described in patients with AIS could be related with the physical deconditioning instead of being linked to the severity of the vertebral deformity.

Methods

Cross-sectional study of the exercise tolerance in a series of patients with AIS type Lenke 1A, before and 2 years after surgical correction. Twenty patients with AIS and 10 healthy adolescents aged between 12 and 17 years old were evaluated. The average magnitude of the curves was 60.3±12.9 Cobb. Cardio-respiratory function was assessed before surgery and at 2-year follow-up by maximal exercise tolerance test on treadmill following a Bruce standard protocol. Maximal oxygen uptake (VO2), VCO2, expiratory volume (VE), and VE/VO2 ratio were registered.


C. Hernandez J. Burgos L.M. Antón V. García E. Hevia C. Barrios

Background

The improvement of the rib cage deformity (RCD) after surgery correction has not been correlated in detail with the correction of vertebral axial rotation (AR). The loss of at the rib cage after correction has been never monitored. The hypothesis of this work was that the aesthetic improvement of RCD in adolescent idiopathic scoliosis (AIS) does not follow completely the reduction of thoracic AR after correction surgery. Moreover, lesser correction of thorax deformity could be expected in mature patients with more rigid curves.

Methods

Multicenter prospective study of the modifications of the rib cage deformity in 24 patients operated because of AIS Lenke type 1A. RDC was assessed in the preoperative MRI exams including the thoracic perimeter. Vertebral AR was quantified by the RaSac angle. Anterior and posterior rib hump, and the translation of the sternum were measured in mm according to standard protocols. All these parameters were assessed in the immediate post-op period and 2-years after surgery using CT-scan axial slides. In all cases, a vertebral derotation technique performed by asymmetric rod bending was used. Immature (Risser 0–2) and mature (Risser 3–4) patients were compared.


E. Hevia A. Paniagua C. Barrios A. Caballero A. Chiaraviglio J. Flores

Background

Recently, some studies have focused attention on the possibility that anaerobic pathogens of low virulence could constitute an etiological factor in disc herniation. There have been isolated such strains, predominantly Propionibacterium acne, between 7 and 53% of patients undergoing surgery for disc pathology. According to these studies, patients with anaerobic infections of the disc are more likely to develop Modic changes in the adjacent vertebrae. The aim of this work was to test this hypothesis by growing in specific media the disc material extracted in a series of lumbar discectomy and relating this factor with the presence of pre-intervention Modic changes.

Methods

A total of 22 consecutive patients undergoing primary unisegmental discectomy for lumbar disc herniation (77.2% male, mean age 40.1 ± 9.1 years) were included. All patients were immunocompetent and none had previously received an epidural steroid injection prior surgery. MRI study confirmed the disc herniation. Following strict antiseptic protocols, the extracted disc material was sent for slow-growth anaerobic enriched culture (>10 days).


Luis M Antón-Rodrigálvarez Jesus Burgos Flores Lidia Cabanes Carlos Barrios Eduardo Hevia Gema de Blas Vicente García

Background

The overall incidence of neurological symptoms attributed to lumbar misplaced screws has been described to occur in 3.48% of patients undergoing surgery. These lumbar radicular neurological lesions are undetected with conventional intraoperative neurophysiological and radiological controls. The hypothesis of this study was that direct stimulation of the pedicle screw after placement in the lumbar spine may not work as well as for screws placed in the thoracic pedicles. A more suitable method for the lumbar spine could be the stimulation of the pedicle track with a ball-tipped probe.

Methods

Comparative observational study on the detection of malpostioned lumbar pedicle screws using two different techniques in two different periods: t-EMG screw stimulation (2011–2012) and track stimulation (2013–2014). A total of 1440 lumbar pedicle screws were placed in 242 patients undergoing surgery for vertebral deformities in the last four years (2011–2014). In the first two years, 802 lumbar screws were neuromonitored using t-EMG during. In the last two years, 638 screws were placed after probe stimulation of the pedicle track. Standardised t-EMG conventional registration and fluoroscopy were afterwards performed in all cases.


J.A. Inzana C. Münch P. Varga L. Hofmann-Fliri N.P. Südkamp M. Windolf

Background

Osteoporotic fracture fixation in the proximal humerus remains a critical challenge. While the biomechanical benefits of screw augmentation with bone cement are established, minimising the cement volume may help control any risk of extravasation and reduce surgical procedure time. Previous experimental studies suggest that it may be sufficient to only augment the screws at the sites of the lowest bone quality. However, adequately testing this hypothesis in vitro is not feasible.

Methods

This study systematically evaluated the 64 possible strategies for augmenting six screws in the humeral head through finite element simulations to determine the relative biomechanical benefits of each augmentation strategy. Two subjects with varying levels of local bone mineral density were each modeled with a 2-part and 3-part fracture that was stabilised with a PHILOS plate. The biomechanical fixation was evaluated under physiological loads (muscle and joint reaction forces) that correspond to three different motions: 45 degrees abduction, 45 degrees abduction with 45 degrees internal rotation, and 45 degrees flexion.


W.A.K. Al-Azzani C.E. Hill C. Passmore A. Czepulkowski A. Mahon A. Logan

Background

Patients with hand injuries frequently present to Emergency Departments. The ability of junior doctors to perform an accurate clinical assessment is crucial in initiating appropriate management.

Objectives

To assess the adequacy of junior doctor hand examination skills and to establish whether further training and education is required.


R.W. Jordan A. Saithna

Background

Distal radius fractures are common injuries but no clear consensus regarding optimal management of unstable fractures exists. Open reduction and internal fixation with volar plates is an increasingly popular but the associated complication rate can be 10%. Intramedullary nails are an alternative offering the potential advantages of reduced risk of tendon injury and intra-articular screw penetration. This article systematically reviews the published literature evaluating the biomechanics, outcomes and complications of intramedullary nails in the management of distal radius fractures.

Methods

A systematic review of Medline and EMBASE databases was performed for studies reporting the biomechanics, functional outcome or complications following intramedullary nailing of distal radius fractures. Critical appraisal was performed with respect to validated quality assessment scales.


A. Patel L. Li A. Rashid

Background

Radial head fractures are the commonest fractures involving the elbow. The goals of treatment are to restore stability, preserve motion, and maintain the relative length of the radius. Fortunately, most simple uncomplicated fractures can be treated non-operatively. Choosing between fixation and radial head replacement for comminuted fractures remains difficult. Excision of radial head fractures is not an ideal option in unstable elbow injuries. The purpose of this systematic review was to search for and critically appraise articles directly comparing functional outcomes and complications for fixation (open reduction internal fixation, ORIF) versus arthroplasty for comminuted radial head fractures (Mason type 3) in adults.

Method

A comprehensive search of Medline, Embase and Cochrane databases using specific search terms and limits was conducted. Strict eligibility criteria were applied to stringently screen resultant articles. Three comparative studies were identified and reviewed.


Y.C. Sun Y.S. Chen F.S. Wang

Background

Epigenetic regulation of gene transcription affects metabolism of chondrocytes and synovial fibroblasts and is associated with the prevalence of osteoarthritis (OA) of knees. Histone lysine demethylase (KDMs) reportedly modulates tissue homeostasis and deterioration. This study investigated whether KMD6a inhibitor treatment affected the joint injuries in the progression of OA.

Methods

Collagenase-induced OA knees in mice were intra-articular administered with KDM6a inhibitor GSK-J4. Walking patterns and footprints of affected animals were detected by Catwalk. Articular cartilage injury was quantified by OARSI scoring; and subchondral bone microstructure was analysed by μCT imaging. Histopathology and mRNA expression of cartilage, fibrosis and bone matrices in joint micro-compartments were detected by histomorphometry and quantitative RT-PCR. Methylation states of chondrogenic transcription factor SOX9 promoter was detected by methylation-specific PCR and chromatin immuno-precipitation.


A. Ezzat C. Iobst

Background

Plate fixation is one of several options available to surgeons for the management of pediatric femur fractures. Recent literature reports distal femoral valgus can be a complication following lateral plate fixation of femur fractures. We report on a case of extreme distal femoral valgus deformity and a lateral dislocation of the patella four years after having plate fixation of a left distal femoral fracture.

Method

A single case was anonymised and retrospectively reviewed through examination of clinical and radiographic data.


C.J. Moran T.J. Levingstone J.M. O'Byrne F.J. O'Brien

Background

The gradient structure of osteochondral tissue, with bone, calcified and cartilage regions, challenges the design of biomaterials for defect repair. A novel biomimetic tri-layered collagen-based scaffold, designed to replicate these 3 anatomical layers, has been developed within our group and has shown success as an off-the-shelf product in treatment of focal defects in several animal models by recruiting host cells and directing them to form bone and cartilage in the requisite layers. This study aimed to elucidate the mechanism by which the extracellular matrix macromolecules in the scaffold directed stem cell differentiation in each layer.

Methods

Tri-layered scaffolds were divided into their three constituent layers. Each layer was individually seeded with rat mesenchymal stem cells (MSCs). Cell infiltration and proliferation, calcium production and sGAG formation were assessed up to 28 days.


L. Barnouin E. Günzel

Background

Based on decellularisation and cleaning processes of trabecular bone and fibrocartilage, an osteochondral allograft has been developed.

Material

The chemical process, established thanks to bone and fibrocartilage data, included an efficient viroinactivation step. The raw material was a tibial plateau collected during knee arthroplasty, cut in cylinders strictly selected (>2mm cartilage height and total height between 10 and 16mm). The grafts were freeze-dried and gamma sterilised.


E. Günzel L. Barnouin P. Delépine F. Le Pape

Background

Meniscal tears are among the most common knee injuries. To preserve as much as possible the joint, partial and total meniscal replacements are necessary. To combine the biocompatibility and mechanical resistance of meniscus allograft with the disponibility of synthetic substitutes, an acellular, viroinactivated and sterile scaffold with well-preserved structure has been developed based on PHOENIX process.

Methods

Human menisci were collected from living donors undergoing total knee arthroplasty. They underwent chemical treatments, freeze-drying and gamma irradiation. Decellularisation of menisci and preservation of the matrix structure were explored by histological studies. Meniscal scaffold ultrastructure was analysed by scanning electron microscopy. Biomechanical studies were also conducted. Scaffold viroinactivation was investigated by viral clearance studies. Finally, the allografts were cultured for 4 weeks with Mesenchymal Stem Cells (CSM); cells viability and proliferation were assessed histologically and by confocal microscopy following stainings.


L. Barnouin N. Ruiz H. Robert

Background

The objective was to evaluate the benefit that could be obtained in terms of pain and efficacy with processed segmental allografts on 20 patients in meniscal repair treatment.

Methods

Segmental meniscal allografts were extracted from tibial plateaux during total knee arthroplasties on lateralised osteoarthritis and selected on macroscopic integrity criteria. They underwent decellularisation and deproteinisation processes to obtain a sterile collagenous matrix with glycosaminoglycans removal. Under arthroscopy, the grafts (50mm length) were fixed at the posterior horn and at the meniscosynovial wall. The main evaluation criterion was the IKDC subjective knee score evolution. Secondary criteria were the meniscus morphology (Magnetic Resonance Imaging after 12 months) and the recellularisation (biopsy after 1 year).


A. Karakasli E. Skiak İ.S. Satoglu N.D. Demirkiran F. Ertem H. Havitcioglu

Background

Bothlimited-contact dynamic compression plate (LC-DCP) and locking compression plate (LCP) systems were designed to provide enhanced bone healing and to improve stability at fracture site. However, implant failure, delayed union, nonunion and instability are still frequently encountered complications. The purpose of this study was to determine the biomechanical characteristics of a novel persistent compression dynamic plate (PCDP) which provides a persistent compression to fracture edges, and to compare the biomechanical properties of such a novel plate with the commonly used LCP.

Methods

The novel persistent compression dynamic plate (PCDP) system is composed of a body, an inner compression spring and a distal mobile component. The body (proximal part) contains an adjustable screw and the distal part of the dynamic system can slide inside the body through a special tube. 12 (saw bone) artificial femoral bones were used. Transverse distal shaft fracture was created in all the saw bones at the same level, 6 femurs were fixed using the novel PCDP, whereas the other 6 femurs were fixed using the well-known LCP. All samples had undergone a nondestructive repetitive different forces (axial compression, bending and torsion), to evaluate the biomechanical differences between the two plating systems.


R. Hurley C. Barry D. Bergin F. Shannon

Background

The anatomy of the human body has been studied for centuries. Despite this, recent articles have announced the presence of a new knee ligament- the anterolateral ligament. It has been the subject of much discussion and media commentary. Previous anatomical studies indicate its presence, and describe its location, origin, course and insertion. Magnetic resonance imaging (MRI) is the best and most commonly used investigation to assess the ligamentous structure of the knee. To date, most MRI knee reports make no mention of the anterolateral ligament. The aim of this study was to assess for the presence of the anterolateral ligament using MRI, and to describe the structure if visualised.

Methods

All right knee MRIs performed on a Siemens Magnetom Espree 1.5 Tesla scanner in Merlin Park Hospital over a 4 year period were retrospectively analysed. Patients born before 1970, or with reported abnormalities were excluded. The normal MRIs were then analysed by a consultant radiologist specialising in musculoskeletal imaging. Measurements on origin, insertion, course and length were noted.


P. Raval R. Ogollah A. Hall N. Foster E. Roddy

Introduction

Subacromial corticosteroid injection is widely used in the treatment of Subacromial Impingement Syndrome (SIS). There is increasing interest in using ultrasound (US) to improve the accurate placement of injections. This study investigated whether the accuracy of placement of US-guided subacromial corticosteroid injections influences patients' outcome of pain and function.

Method

Secondary analysis of data from a 2−2 factorial randomised controlled trial investigating exercise and corticosteroid injection for pain and function in SIS. US-guided injections were delivered according to a pre-defined protocol. Video images were reviewed to categorise accuracy of injection into the subacromial bursa into 3 accuracy groups using pre-defined criteria: 1) not in the subacromial bursa; 2) probably in the subacromial bursa; and 3) definitely in the subacromial bursa. The primary outcome measure was the self-reported Shoulder Pain and Disability Index (SPADI) total score, compared at 6 weeks and 6 months. Secondary outcomes included SPADI pain and function subscales and participant global rating of overall change from baseline. A mixed effects model was used to compare accuracy groups' outcomes at 6 weeks and 6 months, adjusted for baseline covariates.


T. Heigl P. Lichte K. Kloss H. Fischer T. Pufe M. Tohidnezhad

Background

Large bone defects still challenge the orthopaedic surgeon. Local vascularity at the site of the fracture has an important influence on the healing procedure. Vascular endothelial growth factor (VEGF) and it's receptor (VEGFR2) are potent inducer of angiogenesis during the fracture healing. Aim of the present study was the investigation of critical size fracture (CSF) healing in VEGFR2-luc mice using tailored scaffolds.

Methods

CSFs were performed and stabilised in mouse femur using an external fixator. The fracture was bridged using a synthetic 3D printed scaffold with a defined porosity to promote regeneration. The ß-tricalciumphosphate (ßTCP) and strontium doped ß-tricalciumphosphate (ßTCP+Sr) scaffolds were investigated for their regenerative potential. The expression levels of VEGFR2 could be monitored non-invasively via in vivo bioluminescence imaging for 2 months. After the longitudinal measurements the animals were euthanised for an in depth histological endpoint analysis. The different scaffold induced tissue regeneration was quantified for both, the ßTCP and the ßTCP+Sr group.


V. Goriainov R. Pedersen N. Gadegaard D.G. Dunlop R.O.C. Oreffo

Background

Following endosteal uncemented orthopaedic device implantation, the initial implant/bone interface retains spaces and deficiencies further exacerbated by pressure necrosis and resultant bone resorption. This implant-bone space requires native bone infill through the process of de novo osteogenesis. New appositional bone formation on the implant surface is known as contact osteogenesis and is generated by osteogenic cells, including skeletal stem cells (SSCs), colonising the implant surface and depositing the extracellular bone matrix. Surface nanotopographies provide physical cues capable of triggering SSC differentiation into osteoblasts, thus inducing contact osteogenesis, translated clinically into enhanced osseointegration and attainment of secondary stability. The current study has investigated the in vitro and in vivo effects of unique nanotopographical pillar substrates on SSC phenotype and function.

Methods

Adult human SSCs were immunoselected, enriched using STRO-1 antibody and cultured on control and test surfaces for 21 days in vitro. The test groups comprised Ti-coated substrates with planar or modified surfaces with nanopillar. Osteoinductive potential was analysed using qPCR and immunostaining to examine gene expression and protein synthesis.


M.S. Rashid S. Aziz S. Heydar S. Fleming A. Datta

Background

Radiation exposure remains a significant occupational hazard for Orthopaedic surgeons. There are no references values for trauma procedures performed with Image Intensifier (II). We aimed to determine and compare reference values for patient radiation exposure for common trauma operations, and to analyse the effect of surgeon grade on II usage.

Methods

Data collected prospectively from 849 cases between 01/05/2013 and 01/10/2014 were analysed. Statistical analysis was performed to calculate reference values for dose area product (DAP), screening time (ST), and number of II images taken for common trauma procedures where n>9 (n=808).


E. García-Rey E. García-Cimbrelo E. Gómez-Barrena

Background and aim

Recent proposals have been introduced to modify stem design and/or femoral fixation in total hip replacement (THR). New designs need to consider previous design features and their results. The aim of this study has been to evaluate the clinical and radiological results of six different designs of tapered uncemented stems implanted in our Institution.

Methods

1918 uncemented hips were prospectively assessed from 1999 to 2011 (minimum follow-up of five years for the unrevised hips). All hips had a 28 or 32 mm femoral head and metal-on-polyethylene or alumina-on-alumina bearing surface. Six uncemented femoral designs that shared a femoral tapered stem incorporating a coating surface were included in the study. The different design features included the type of coating, metaphyseal filling, and sectional shape.


W.A.K. Al-Azzani D.A. Mak P. Hodgson R. Williams

Background

We reproduced a frequently cited study performed at our University Hospital that was published in the British Medical Journal in 1981 assessing the extent of “snow and ice” fractures during the winter period.

Methods

As per the original study, four days of snow and ice were identified as well as two control periods when snow and ice wasn't recorded; four days within the same year, with a similar amount of sunshine hours, and four days one calendar year later. The distribution of fractures according to age and sex in addition to the anatomical location were examined in relation to the presence of snow and ice as well as comparisons with the index study 33 years ago.


F.S. Wang Y.C. Sun Y.S. Chen J.Y. Ko

Background

Long-term glucocorticoid treatment increases incidence of osteoporotic or osteonecrotic disorders. Excessive bone loss and marrow fat accumulation are prominent features of glucocorticoid-induced osteoporosis. MicroRNA-29 (miR-29) family members reportedly modulate lineage commitment of stem cells. This study was undertaken to define the biological roles of miR-29a in skeletal and fat metabolism in the pathogenesis of glucocorticoid-induced osteoporosis.

Methods

Osteoblast-specific miR-29a transgenic mice (Tg) driven by osteocalcin promoter (C57BL/6JNarl-TgOCN-mir29a) or wild-type (WT) mice were given methylprednisolone. Bone mass, trabecular and cortical bone microarchitecture were assessed by μCT. Comparative mRNA and protein expression was quantified by RT-PCR and immunoblotting. Primary bone-marrow mesenchymal cells were isolated for elucidating ex vivo osteogenic and adipogenic differentiation capacity.


Y.S. Cheng F.S. Wang Y.C. Su J.Y. Ko

Background

MicroRNAs are non-coding small RNAs that reportedly regulate mRNA targets or protein translation of various tissues in physiological and pathological contexts. This study was undertaken to characterise the contributions of microRNA-29a (miR-29a) to the progression of estrogen deficiency-mediated excessive osteoclast resorption and bone loss.

Methods

Osteoblast-specific transgenic mice overexpressing miR-29a driven by osteocalcin promoter (C57BL/6JNarl-TgOCN-mir29a) or wild-type mice were subjected to bilateral ovariectomy. Bone mineral density, trabecular microarchitecture and osteoclast distribution was quantified by μCT and histomorphometry. Primary CD11b+CSF-1R+ preosteoclasts were isolated for detecting ex vivo osteoclast differentiation. Gene expression and transcription factor-promoter interaction were quantified by RT-PCR and chromatin immunoprecipitation.


J. Palmer A. Palmer L. Jones W. Jackson S. Glyn-Jones A. Price

Background

Since 2011, the knee service at the Nuffield Orthopaedic Centre has been offering a neutralising medial opening wedge high tibial osteotomy (HTO) to a group of patients presenting with early medial osteoarthritis of the knee, varus alignment and symptoms for more than 2 years. During development of this practice an association was observed between this phenotype of osteoarthritis and the presence of CAM deformity at the hip.

Methods

A retrospective cohort study. All patients who underwent HTO since 2011 were identified (n=30). Comparator groups were used in order to establish whether meaningful observations were being made: Control group: The spouses of a high-risk osteoarthritis cohort recruited for a different study at our unit (n=20) Pre-arthroplasty group: Patients who have undergone uni-compartmental arthroplasty (UKA) for antero-medial osteoarthritis (n=20)All patients had standing bilateral full-length radiographs available for analysis using in house developed Matlab-based software for hip measurements and MediCAD for lower limb alignment measurements.


F. Gindraux K. Oudina A. Nallet B. de Billy H. Petite L. Obert

Previous clinical studies have shown the efficacy of a foreign body-induced membrane combined with bone autograft for the reconstruction of traumatologic or pathologic large bone defects or, bone non union. This membrane, rich in mesenchymal stromal cells (MSC), avoids bone autograft resorption and promotes consolidation by revascularisation of the bone and secretion of growth factors. Reconstruction requires two different surgical stages: firstly, insertion of a cement spacer in the defect, and secondly, removal of the spacer, preservation of the foreign body-induced membrane and filling of the cavity by bone autograft. The optimal time to perform the second surgical stage remains unclear.

So, we aimed to correlate bone healing and, phenotype and function of cells isolated from the induced membrane, in patients whose second surgery was performed on average after 6 months (i.e. beyond the recommended time of one month). Cell phenotype was determined by flow cytometry and cell function by: alkaline Phosphatase enzyme activity, secretion of calcium and von Kossa staining. Second, using histological and immunohistochemistry studies, we aimed to determine the nature and function of induced membrane over time. Seven patients were included with their consent.

Results showed Treated patients achieved in all cases bone union (except for one patient) and in in vitro and histology and immunohistochemistry gave some indications which need to be completed in the future. First, patient age seemed to be an indicator of bone union speed and recurrent infection, appeared to influence in vitro MSC osteogenic potential and induced membrane structure. Second, we reported, in bone repair situation, the commitment over time in osteogenic lineage of a surprising multipotent tissue (induced membrane) able of vascularisation/ osteogenesis/ chondrogenesis at a precocious time. Finally, best time to perform the second stage (one month) could be easily exceeded since bone union occurred even at very late times.


R.W. Jordan G. Chahal M. Davies K. Srinivas

Background

Patients suffering a distal femoral fracture are at a high risk of morbidity and mortality. Currently this cohort is not afforded the same resources as those with hip fractures. This study aims to compare their mortality rates and assess whether surgical intervention improves either outcome or mortality following distal femoral fractures.

Methods

Patients over sixty-five admitted with a distal femoral fracture between June 2007 and 2012 were retrospectively identified. Patients mobility was categorised as unaided, walking aid, zimmer frame, or immobile. The 30-day, six-month, and one-year mortality rates were recorded for this group as well as for hip fractures during the same period.


Full Access
E. Hughes R. Williams G. Chouhan P. Jamshidi L. Grover

Background

Calcium orthophosphates, such as hydroxyapatite (Ca5(PO4)3OH) (HA), have long been employed as bone graft materials. Recent work has suggested that calcium pyrophosphate (Ca2P2O7) (CaPy) may strongly stimulate bone deposition. In this study we compare calcium orthophosphate and pyrophosphate precipitates as suitable bone regeneration materials. As well as HA, two forms of pyrophosphate precipitate were compared in this work: amorphous calcium pyrophosphate (amCaPy) and star particle calcium pyrophosphate (stCaPy).

Methods

Briefly, 0.15M Na4P2O7·10H2O and 0.3M Ca2Cl·2H2O solutions of equivalent volume were combined and left to age before performing a series of filtration and re-suspension steps upon the precipitate. Drying yielded amCaPy powder. stAmPy was produced by the same procedure however the pH of the starting solutions were altered to pH7 before combination.


R.W. Jordan A. Saithna

Background

Despite arthroscopy being the gold standard for long head of biceps pathology, the literature is seemingly lacking in any critical appraisal or validation to support its use. The aim of this study was to evaluate its appropriateness as a benchmark for diagnosis. The objectives were to evaluate whether the length of the tendon examined at arthroscopy allows visualisation of areas of predilection of pathology and also to determine the rates of missed diagnoses when compared to an open approach.

Methods

A systematic review of cadaveric and clinical studies was performed. The search strategy was applied to Medline, PubMed and Google Scholar databases. All relevant articles were included. Critical appraisal of clinical studies was performed using a validated quality assessment scale.


A.I. Simpson R. Dattani R.A. Sankey

Background

Radiological and clinical results of total shoulder arthroplasty are dependent upon ability to accurately measure and correct glenoid version. There are a variety of imaging modalities and computer-assisted reconstruction programmes that are employed with varying degrees of success. We have compared three freely available modalities: unformatted 2D CT; formatted 2D CT; and 3D CT reconstructions.

Methods

A retrospective analysis of 20 shoulder CT scans was performed. Glenoid version was measured at the estimated mid-point of the glenoid from unformatted 2D CT scans (Scapula body method) and again following formatting of 2D CT scans in the plane of the scapula (Friedman method). 3D scapula reconstructions were also performed by downloading CT DICOM images to OSIRIX 6 and plotting ROI points on Friedman's axis to most accurately define glenoid version. Both measurements taken from 2D CT were compared to those from 3D CT. Eleven CT scans were of male patients, 9 female. Mean age was 55.2 years (Range: 23–77 years). Fourteen scans were performed for trauma, 6 for arthroplasty. Twelve scans were of the left shoulder.


A.E. Oostlander A.M. Moerman A.A. Zadpoor M.A.E. Schoeman R.G.H.H. Nelissen E.R. Valstar

Background

Periprosthetic osteolysis is the most common long-term complication of a total joint arthroplasty, often resulting in aseptic loosening of the implant. As we aim at developing a safe and minimally invasive implant refixation procedure, thorough characterisation of the properties of the periprosthetic tissue is needed.

Methods

In this pilot study, the periprosthetic tissue of eleven patients undergoing hip revision surgery due to aseptic loosening was obtained. Histology, confocal microscopy, atomic force microscopy (AFM) and nanoindentation were performed to structurally and mechanically characterise the tissue. The study was approved by the Medical Ethical Committee of the Leiden University Medical Center.


E. Lenguerrand V. Wylde R. Gooberman-Hill A. Sayers P. Dieppe A. W. Blom

Background

While many studies have investigated long-term outcomes after lower limb arthroplasty, rather less is known about the trajectory of short-term outcomes in the first post-operative year. It is difficult for a surgeon to know when, in terms of disease severity, it is best to operate, or to make an accurate prediction of the patient pattern of post-operative recovery. We explored the trajectory of change in pain and function following primary hip and knee arthroplasty and the influence of pre-operative self-reported symptoms on post-operative improvements.

Methods

A prospective UK cohort study of 164 patients undergoing primary hip (n=80) or knee (n=84) arthroplasty. WOMAC pain and function measures were collected pre-operatively and at 3 and 12 months post-operatively. Hip and knee arthroplasties were analysed separately, and patients were split into two groups: those with high or low symptoms pre-operatively. Multilevel regressions were used for each outcome (pain and function), and the trajectory of change (0–3 months and 3–12 months) charted. The study was approved by Southwest 4 Research Ethics Committee (09/H0102/72) and all patients provided informed, written consent. The authors have no competing interests to disclose.


A. Ezzat J. Lovejoy K. Alexander

Background

North America is facing a rising epidemic involving strains of methicillin-resistant Staphylococcus aureus (MRSA) that, instead of being found almost exclusively in hospitals, are community-associated (CA-MRSA). These strains are aggressive, associated with musculoskeletal manifestations including osteomyelitis (OM), and septic arthritis (SA). We aimed to establish novel management algorithms for acute OM and SA in children. We investigated S.aureus susceptibilities to current first-line antimicrobials to determine their local efficacy.

Methods

The project was conducted at Nemours Children Hospital in Florida, USA, following approval by the internal review board. A literature review was conducted. An audit of S.aureus antimicrobial sensitivities was completed over three years and compared against national standards. Susceptibilities of clindamycin, trimethoprim/sulfamethoxazole (TMP/SMX) and vancomycin were studied using local resistance ranges.


R. Lerf I. Reimelt F. Dallmann D. Delfosse

Background

When reversing the hard-soft articulation in inverse shoulder replacement, i.e. hard inlay and soft glenosphere, the tribological behaviour of such a pairing has to be tested thoroughly. Therefore, two hard materials for the inlay, CoCr alloy and alumina toughened zirconia ceramic (ATZ) articulating on two soft materials, conventional UHMWPE and vitamin E stabilised, highly cross-linked PE (E-XLPE) were tested.

Methods

The simulator tests were performed analogue to standardised gravimetric wear tests for hip prosthesis (ISO 14242-1) with load and motion curves adapted to the shoulder. The test parameters differing from the standard were the maximum force (1.0 kN) and the range of motion. A servo-hydraulic six station joint simulator (EndoLab, Rosenheim) was used to run the tests up to 5 times 106 cycles with diluted calf serum at 37° C as lubricant.


J.R.A. Smith R. Halliday A.L. Aquilina P. Hull M.B. Kelly

Background

Hip fracture care has evolved, largely due to standardisation of practice, measurement of outcomes and the introduction of the Best Practice Tariff, leading to the sustained improvements documented by the National Hip Fracture Database (NHFD). The treatment of distal femoral fractures in this population has not had the same emphasis. This study defines the epidemiology, current practice and outcomes of distal femoral fractures in four English centres.

Methods

105 patients aged 50 years or greater with a distal femoral fracture, presenting to four UK major trauma centres between October 2010 and September 2011 were identified. Data was collected using an adapted NHFD data collection tool via retrospective case note and radiograph review. Local ethics approval was obtained.


A. Karaaslan A. Karakaşlı F. Ertem H. Aycan

Background

Intramedullary nailing is a widely accepted treatment method for femoral fractures. Failure of locking screws is often a threatening complication, particularly on comminuted fractures. For comminuted fractures, the locking nails are load-bearing devices. The load transfer between fractured fragments is made through especially the locking screws for these load bearing situations. Nonunion, malunion, delayed union, shortening, and nail migration are the expected results if early failure of locking screws is present with comminuted fractures. In this study our aim was to compare the bending resistance of titanium and stainless steel locking screws.

Methods

We tested 60 locking screws in six groups (titanium, stainless steel, unthreaded, low threaded and high threaded) in a steel tube that has 30 mm inner diameter, which imitates the lesser trochanter level. We determined the yield points at three-point bending tests that permanent deformation started in the locking screws using an axial compression testing machine.


K. Ahmed A. Pillai K. Somasundaram

Background

Patient reported outcomes measures are a fundamental part of the NHS. Since 2009, they have been used to measure quality from the patient's perspective. PROMS2.0 is a semi-automated web based system, which allows collection and analysis of outcome data. This study looks at the factors, which can influence PROMS. These include looking at general trends which affect reported outcomes such as surgeon, age and gender. We also look to assess the reasons for non-uptake in the study.

Methods

Data was collected from October 2012 to March 2015. Scores used to asses outcome measures included EQ-5D VAS, EQ-5D Health Index, and MOxFQ, collected pre-operatively and post-operatively.


S.A.A.N. Bolink E. Lenguerrand A.W. Blom B. Grimm

Background

Assessment of functional outcome after total hip arthroplasty (THA) often involves subjective patient-reported outcome measures (PROMs) whereas analysis of gait allows more objective assessment. The aims of the study were to compare longitudinal changes of WOMAC function score and ambulatory gait analysis after THA, between patients with low and high self-reported levels of physical function.

Methods

Patients undergoing primary THA (n=36; m/f=18/18; mean age=63.9; SD=9.8yrs; BMI=26.3 SD=3.5) were divided in a high and low function group, on their preoperative WOMAC function score. Patients were prospectively measured preoperatively and 3 and 12 months postoperatively. WOMAC function scores 0–100) were compared to inertial sensor based ambulatory gait analysis.


A. Sayers V. Wylde E. Lenguerrand R. Gooberman-Hill J. Dawson D. Beard A. Price A.W. Blom

Background

This article reviews four commonly used approaches to assess patient responsiveness to a treatment or therapy [Return To Normal (RTN), Minimal Important Difference (MID), Minimal Clinically Important Difference (MCID), OMERACT-OARSI (OO)], and demonstrates how each of the methods can be formulated in a multi-level modelling (MLM) framework.

Methods

Data from the Arthroplasty Pain Experience (APEX) cohort study was used. Patients undergoing total hip and knee replacement completed the Intermittent and Constant Osteoarthritis Pain (ICOAP) questionnaire prior to surgery and then at 3, 6 and 12 months after surgery. We compare baseline scores, change scores, and proportion of individuals defined as “responders” using traditional and multi-level model (MLM) approaches to patient responsiveness.


I. Bohler N. Malek A. Vane

Background

Positioning of the acetabular component in total hip arthroplasty has profound effects on the biomechanics, stability and wear of the prosthesis. Normal anatomical position in females is 57 degrees (50 – 67 degrees) inclination with 19 degrees (9 – 32 degrees) of anteversion, whilst in males 56 degrees of inclination (48 – 66 degrees) with 19 degrees (9 – 32 degrees) is normal. In total hip arthroplasty, inclination recommendation ranges from 30 – 50 degrees. The aim of this study was to radiographically measure acetabular component position in total hip arthroplasty and compare to normal values.

Method

The Widmer method was used by two independent observers to radiographically measure inclination in 522 patients using standard AP radiographs. Primary measures and variables were statistically analysed as was inter and intra observer reliability. All patients included within the study received total hip arthroplasty for age related degenerative changes to the hip. Operations were undertaken by 17 separate consultants or senior registrars under their care.


V.N. Gibbs H.G.R. Lowdon T. Barlow

Background

Multiple randomised controlled trials have demonstrated that arthroscopy provides little benefit in patients with knee osteoarthritis. In 2008, NICE released guidelines to reflect this evidence. Implementation has been sporadic, and arthroscopy for knee osteoarthritis is commonly performed with an annual incidence of 9.9 per 10,000 in England. Our aim was to establish whether previous arthroscopy affects Patient Reported Outcome Measures (PROMs) in Total Knee Replacement (TKR) patients.

Methods

Data was retrospectively collected from 2010–2012 from a University hospital. Pre-operative and one-year post-operative PROMs were collected on patients who had undergone arthroscopy and then TKR, or only TKR. The change in PROMs score over TKR was then compared between groups.


V. Povoroznyuk M. Bystrytska

Aim

The aim of the study was to define the peculiarities of bone remodeling and identify specific parameters to development to heterotopic ossification.

Materials and methods

Markers of bone formation (Osteocalcin, serum type 1 procollagen (N-terminal) (tP1NP)) and bone resorption (serum collagen type 1 cross-linked C-telopeptide (β-CTx)) were determined by the electrochemiluminiscence immunoassay “ECLIA” for Elecsys user cobas immunoassay analyser. In the study were included 23 patients with spinal cord injury – first group (average age 26.8 ± 3.9, duration of spinal cord injury from 3 to 12 months) and 23 healthy people's appropriate age and gender (average age 30.6 ± 6.0, years). In the first group included 11 patients with spinal cord injury with the presence of heterotopic ossification – subgroup I and 12 patients with spinal cord injury without heterotopic ossification – subgroup II.


W.A.K. Al-Azzani H.J. Iqbal A.J. Thayaparan S.P. White

Background

The incidence of bleeding following primary TKR has increased with the use of chemical thromboprophylaxis. Our aim was to compare Clexane, Apixaban and Rivaroxaban in terms of frequency and volume of bleeding episodes, need for blood transfusion, return to theatre and incidence of VTE events.

Methods

Between February and May 2014, a consecutive series of 132 primary TKRs were studied prospectively. The wound dressings of these patients were assessed daily to look for signs of bleeding and classified into: Mild (< 50p size coin), moderate (> 50p size coin) or Severe (blood seeping through the dressing). Follow up was up to minimum of 30 days post discharge.


W.A.K. Al-Azzani H.J. Iqbal Y. Al-Soudaine A.J. Thayaparan M.I.M. Suhaimi S. Masud S.P. White

Background

Increasing number of studies investigating surgical patients have reported longer length of stay (LOS) in hospital after an operation with higher ASA grades. However, the impact of Body Mass Index (BMI) on LOS in hospital post Total Knee Replacement (TKR) remains a controversial topic with conflicting findings in reported literature. In our institution, we recently adopted a weight reduction program requiring all patients with raised BMI to participate in order to be considered for elective TKR.

Objectives

This has prompted us to investigate the impact BMI has on LOS compared to the more established impact of ASA grade on patients following Primary TKR.


S. Descamps G. Villatte C. Massard C. Forrestier K.O. Awitor

Background

External fixation is a method of osteosynthesis currently required in traumatology and orthopaedic surgery. Pin tract infection is a common problem in clinical practice. Infection occurs after a bacterial colonisation of the pin due to its contact with skin and local environment. To prevent such local contamination, one way to handle this issue is to create a specific coating using method which could be applied in the medical field. In this work we develop a surface coating for external fixator pins based on photocatalytic TiOα properties, producing a bactericidal effect with sufficient mechanical strength to be compatible with surgical use.

Method

The morphology and structure of the sol-gel coating layers were characterised using, respectively, scanning electron microscopy and X-ray diffraction. Resistance properties of the coating were investigated by mechanical testing. Photo-degradation of acid orange 7 in aqueous solution was used as a probe, to assess the photo-catalytic activity of titanium dioxide layers under UV irradiation. The bactericidal effect induced by the process was evaluated against 2 strains: a Staphylococcus aureus and a multiresistant Staphylococcus epidermidis.


C. Kocialkowski C. Peach

Background

Functional outcomes of conservatively managed, valgus impacted proximal humeral fractures are poor. Operative fixation can improve results but can be technically challenging. We prospectively assessed outcomes following fixation of valgus unstable proximal humeral fractures with a novel hybrid fixed angle blade plate, at a minimum of 12 months follow up.

Methods

A new hybrid fixed angle blade plate design (Fx Plate, Exactech, Gainesville, USA) was used by the senior author to treat patients with displaced and potentially valgus unstable proximal humeral fractures, at our institution between November 2012 and March 2014. The study was approved by the research and development department. Outcomes were prospectively assessed using the Oxford and Constant shoulder scores and quality of life was assessed using the SF-36 questionnaire. Radiographs were taken at regular intervals to assess fracture healing.


P. Turner N. Choudhry R.N. Green N.M. Aradhyula

Background

Distal femoral fractures are 10 times less common than hip fractures. 12-month mortality has been reported as 25–30% but there is no longer-term data. In Northumbria hip fractures have a 5-year mortality of 68%.

Objectives

To analyse 5-year mortality in distal femur fractures in the Northumbrian NHS trust, and identify risk factors for mortality. To compare the results to literature standards and Northumbrian hip fracture data.


C. Kocialkowski N. Philips C. Peach

Aim

Prospectively assess the degree of finger swelling after shoulder arthroscopy, to determine whether rings should be routinely removed prior to surgery.

Method and Results

Patients undergoing shoulder arthroscopic procedures had finger diameters measured prior and post surgery, over a three month period. The study was approved by our Research and Development department. Measurements were taken using a finger circumference gauge (Southpointe, Florida, USA) and were all performed by one researcher in a standard technique, to eliminate inter observer variability. Control measurement, using the contralateral hand, were taken. Statistical analysis was performed, using the Mann Whitney U test. 31 patients undergoing shoulder arthroscopy were included in the study and had finger diameters assessed. The median amount of finger swelling on the operated side was 2.8 mm (IQR 4.6) per digit, compared to 0 mm on the contralateral side (IQR 1.6), which was significantly greater (p=0.0003). There was no statistical difference in the amount of finger swelling when patients undergoing short procedures (less than 30 minutes operating time) were compared to patients undergoing long procedures (greater than 60 minutes).


J.B. Monsef T. Schmidt-Braekling A. Gonzalez Della Valle M. Parks T. Sculco F. Boettner

Background

Tranexamic acid (TXA) and fibrin sealants have gained widespread use in total knee arthroplasty. They can decrease bleeding, drainage volume, hematoma formation, and incidence of blood transfusion. However, they are costly and carry a theoretical risk of infection transmission and thrombosis. This study compares the two pharmacologic interventions to preoperative autologous blood donation as well as no intervention.

Methods

This prospective study evaluated a process change within our blood management program over the last five years. The program began initially with a comparison of only routine hemostasis compared to routine preoperative autologous blood donation (PABD) for all patients (Group 1), which then evolved into a targeted PABD protocol where only anaemic patients predonated (Group 2). Subsequently, patients received topical fibrin sealant for a year (Group 3), after which the topical TXA protocol was introduced and is still in place (Group 4).


S.K. Kunutsor M.R. Whitehouse A.W. Blom A.D. Beswick

Background

The two-stage revision strategy has been claimed as being the “gold standard” for treating prosthetic joint infection. The one-stage revision strategy remains an attractive alternative option, however, its effectiveness in comparison to the two-stage strategy remains uncertain. A systematic review and meta-analysis was conducted to compare the effectiveness of one- and two-stage revision strategies to prevent re-infection after prosthetic hip infection.

Methods

Cohort studies (prospective or retrospective) conducted in unselected patients with infection treated exclusively by one- or two-stage revision and reporting re-infection outcomes within two years of revision were retrieved from MEDLINE, EMBASE, Web of Science, Cochrane databases, manual search of bibliographies to March 2015, and email contact with investigators. Data were extracted by two independent investigators and a consensus was reached with involvement of a third. Rates of re-infection were aggregated using random-effect models after arcsine transformation, and were grouped by study and population level characteristics.


A. Bhattacharjee R. Freeman A. Roberts N.T. Kiely

Methods

A retrospective review of 80 patients with unilateral slipped capital femoral epiphysis from 1998–2012 was undertaken to determine the outcome of the unaffected hip. All patients were treated with either prophylactic single Richards screw fixation or observation of the uninvolved hip and were followed up for at least 12 months. The unaffected hip of 44 patients (mean age 12.6 years, range 9–17) had simultaneous prophylactic fixation and 36 patients (mean age 13.4 years, range 9–17.4) were managed with observation.

Results

Sequential slip of the unaffected hip was noted in 10 patients (28 per cent) in the observation group and only in 1 patient (2 per cent) in the group managed with prophylactic fixation. A Fisher's exact test showed significantly high incidence of sequential slip in unaffected hips when managed with regular observation (p-value 0.002). Only 3 cases had symptomatic hardware on the unaffected side after prophylactic fixation with one requiring revision of the metal work; one had superficial wound infection treated with antibiotics. No cases had AVN or chondrolysis.


M. Gasik

For evaluation of orthopaedic biomaterials the closest hostile-like in vitro environments are desirable with relevant control of chemical, biological, mechanical etc. parameters. For faster screening and reduction of time and costs, combination of different critical key parameters in minimal tests is needed. New trends also favour minimisation of in vivo (2010/63/EC, towards replacement technology) and clinical tests (2001/20/EC, 2005/28/EC) for new products yet not compromising risks. Biomaterials manufacturers also are interested in shortening of the time-to-market keeping conformity to essential requirements and withstanding the simulated “worst case” conditions (2003/94/EC). Here we show the new approach of the creation of conditions closest to real life and applications, based on scientifically designed and optimised models, aiming on predictive outputs. With new device and designed protocols, several biomaterials for orthopaedic applications were analysed: titanium, biodegradable fibrous scaffolds and hydrogels. Creation of several favourable conditions for different tissues type formation took place on the surface of the porous titanium specimen. Such conditions could be designed for measurement of the cells proliferation and e.g. simultaneous bacterial adhesion with rather high precision. The method has been compared in independent laboratories for hydrogels with other measuring techniques and shown the benefits of the method especially in more precise control of biomechanical cues. It was observed that significant amount of data are containing in the recorded signals which underlines the importance of correct and holistic data post-processing. The protocols can be furthermore tailored to simulate different conditions, such as for specific positions in tibia, or humeral etc., and combined with patient-specific biomechanics (soft tissues) for customised implant design. The financial support from the Finnish Agency of Innovation (Tekes) is gratefully acknowledged.

Author has no competing financial or conflicting interests.


R. Lerf C. Witt D. Delfosse

Background

Simply stated, carbon reinforced carbon (C/C) may be considered as fibre reinforced pyrocarbon. Pyrocarbon is used e.g. in finger joints and artificial heart valves. Aim of the present study was to evaluate if C/C could broaden the field of orthopaedic applications compared to pyrocarbon. Technically, C/C is used e.g. for brakes of F-1 race cars.

Methods

The mechanical strength of the C/C material was characterised by a biaxial flexural bending test according ISO 6474-1. Three C/C shoulder heads articulating against vitamin E stabilised, highly cross-linked UHMWPE (E-XLPE) underwent a shoulder simulator study up to 106 cycles. The Coefficient of Friction (CoF) of C/C disks (Ra: 0.045 μm) against cartilage was analysed by a reciprocal cartilage wear tester. The test was conducted in cell culture medium for 4 h and 12 h using bovine cartilage. All test data is compared to the corresponding test results with Al2O3 ceramic.


S. Van Onsem D. Lambrecht M. Verstraete C. Van Der Straeten J. Victor

Introduction

Better functional outcomes, lower pain and better stability have been reported with knee designs which restore physiological knee kinematics. Also the ability of the TKA design to properly restore the physiological femoral rollback during knee flexion, has shown to be correlated with better restoration of the flexor/extensor mechanism, which is fundamental to the function of the human knee. The purpose of the study is to compare the kinematics of three different TKA designs, by evaluating knee motion during Activities of Daily Living. The second goal is to see if there is a correlation between the TKA kinematics and the patient reported outcomes.

Methods

Ten patients of each design, who are at least 6 months after their Total Knee Replacement, will be included in this study. Seven satisfied and 3 dissatisfied patients will be selected for each design. In this study 5 different movements will be analysed: flexion/extension; Sitting on and rising from a chair, Stair climbing, descending stairs, Flexion and extension open chain and squatting. These movements will be captured with a fluoroscope. The 2D images that are obtained, will be matched with the 3D implants. This 3D image will be processed with custom-made software to be able to analyse the movement. Tibio-femoral contact points of the medial and lateral condyles, tibio-femoral axial rotation, determination of the pivot-point will be analysed and described. After this analysis, a correlation between the kinematics and the KOOS and KSS will be investigated.


S. Herregodts P. De Baets J. Victor M. Verstraete

Background

Biomechanical joint contact pressure distribution measurements have proven to be a very valuable tool in orthopaedic research to investigate the influence of surgical techniques such as total knee arthroplasty (TKA) on the human knee joint. Quantification of the in vitro tibiofemoral and patellofemoral contact pressure distribution before and after the intervention are an important measure to evaluate the impact of the surgery. The K scan pressure sensor from Tekscan (South Boston USA) is a commonly reported device for these in vitro pressure measurements. Despite the large interest in the sensor, the effective measurement accuracy for in vitro biomechanical joint contact measurement still remains a big question and therefore the reliability of these measurements should be questioned.

Methods

Reliable contact pressure measurements can only be done if the sensor behaviour is fully understood. Therefore, a tailored multi-axial testing machine has been designed to profoundly investigate and characterise the sensor behaviour. This test setup is unique through its ability to apply a predefined tangential force or sliding velocity to the sensor's interface next to a normal force. Dynamic effects occurring in knee joint motion can thus be simulated while evaluating the effect on the contact pressure measurements.