Abstract
Background
The anatomy of the human body has been studied for centuries. Despite this, recent articles have announced the presence of a new knee ligament- the anterolateral ligament. It has been the subject of much discussion and media commentary. Previous anatomical studies indicate its presence, and describe its location, origin, course and insertion. Magnetic resonance imaging (MRI) is the best and most commonly used investigation to assess the ligamentous structure of the knee. To date, most MRI knee reports make no mention of the anterolateral ligament. The aim of this study was to assess for the presence of the anterolateral ligament using MRI, and to describe the structure if visualised.
Methods
All right knee MRIs performed on a Siemens Magnetom Espree 1.5 Tesla scanner in Merlin Park Hospital over a 4 year period were retrospectively analysed. Patients born before 1970, or with reported abnormalities were excluded. The normal MRIs were then analysed by a consultant radiologist specialising in musculoskeletal imaging. Measurements on origin, insertion, course and length were noted.
Results
942 right knee MRIs were performed in the time period. 62 were classed as normal, and within the specified age range. 10 were randomly sampled. Of these the ligament was visible on all 10 MRIs, best viewed in the coronal plane. The average length (visible in 8/10) was 28.88mm +/− 5.14mm. The origin (visible in all 10) was 2.25mm +/− 0.39mm. The insertion (visible in 9/10) was 1.93mm +/− 0.424. The mid thickness was 1.87mm +/− 0.2mm.
Conclusions
This study indicates that the ALL is a discrete, visible structure on MRI. This furthers the evidence of the presence of the ALL and also provides information that may be beneficial in future studies, and assessment of knee injuries.
Level of evidence
4