Purpose. We aimed to investigate whether the anterior superior iliac spine could provide consistent rotational landmark of the tibial component during mobile-bearing medial unicompartmental knee arthroplasty (UKA) using computed tomography (CT). Methods. During sagittal tibial resection, we utilized the ASIS as a rotational landmark. In 47 knees that underwent postoperative CT scans after medial UKA, the tibial component position was assessed by drawing a line tangential to the lateral wall of the tibial component. Rotation of the tibial component was measured using two reference lines: a line perpendicular to the posterior cortical rim of the tibia (angle α) and Akagi's line (angle β). Instant bearing position and posterior cruciate ligament fossa involvement were also evaluated. External rotation of the tibial component relative to each reference line and external rotation of the bearing relative to the lateral wall of the tibial component were considered positive values. Results. The mean angle α and β were 8.0 ± 6.1° (range, −4.0 – 24.3) and 8.7 ± 4.8° (range, 1.9 – 25.2), respectively. The mean instant bearing position was 4.3 ± 28.6° (range, −52.9 – 179.7). One bearing showed complete 180° rotation at 2 weeks postoperatively. Fourteen knees (29.8%) showed posterior cruciate ligament fossa involvement of the tibial resection margin. Conclusions. Due to the wide variation in, and inherent difficulty in identification of, the ASIS during the operation, it is not recommended for guidance of sagittal tibial resection during mobile-bearing medial UKA. Level of Evidence: Level IV


Bone & Joint Research
Vol. 10, Issue 8 | Pages 467 - 473
2 Aug 2021
Rodríguez-Collell JR Mifsut D Ruiz-Sauri A Rodríguez-Pino L González-Soler EM Valverde-Navarro AA

Aims. The main objective of this study is to analyze the penetration of bone cement in four different full cementation techniques of the tibial tray. Methods. In order to determine the best tibial tray cementation technique, we applied cement to 40 cryopreserved donor tibiae by four different techniques: 1) double-layer cementation of the tibial component and tibial bone with bone restrictor; 2) metallic cementation of the tibial component without bone restrictor; 3) bone cementation of the tibia with bone restrictor; and 4) superficial bone cementation of the tibia and metallic keel cementation of the tibial component without bone restrictor. We performed CT exams of all 40 subjects, and measured cement layer thickness at both levels of the resected surface of the epiphysis and the endomedular metaphyseal level. Results. At the epiphyseal level, Technique 2 gave the greatest depth compared to the other investigated techniques. At the endomedular metaphyseal level, Technique 1 showed greater cement penetration than the other techniques. Conclusion. The best metaphyseal cementation technique of the tibial component is bone cementation with cement restrictor. Additionally, if full tibial component cementation is to be done, the cement volume used should be about 40 g of cement, and not the usual 20 g. Cite this article: Bone Joint Res 2021;10(8):467–473


The Bone & Joint Journal
Vol. 104-B, Issue 4 | Pages 444 - 451
1 Apr 2022
Laende EK Mills Flemming J Astephen Wilson JL Cantoni E Dunbar MJ

Aims. Thresholds of acceptable early migration of the components in total knee arthroplasty (TKA) have traditionally ignored the effects of patient and implant factors that may influence migration. The aim of this study was to determine which of these factors are associated with overall longitudinal migration of well-fixed tibial components following TKA. Methods. Radiostereometric analysis (RSA) data over a two-year period were available for 419 successful primary TKAs (267 cemented and 152 uncemented in 257 female and 162 male patients). Longitudinal analysis of data using marginal models was performed to examine the associations of patient factors (age, sex, BMI, smoking status) and implant factors (cemented or uncemented, the size of the implant) with maximum total point motion (MTPM) migration. Analyses were also performed on subgroups based on sex and fixation. Results. In the overall group, only fixation was significantly associated with migration (p < 0.001). For uncemented tibial components in males, smoking was significantly associated with lower migration (p = 0.030) and BMI approached significance (p = 0.061). For females with uncemented components, smoking (p = 0.081) and age (p = 0.063) approached significance and were both associated with increased migration. The small number of self-reported smokers in this study warrants cautious interpretation and further investigation. For cemented components in females, larger sizes of tibial component were significantly associated with increased migration (p = 0.004). No factors were significant for cemented components in males. Conclusion. The migration of uncemented tibial components was more sensitive to patient factors than cemented implants. These differences were not consistent by sex, suggesting that it may be of value to evaluate female and male patients separately following TKA. Cite this article: Bone Joint J 2022;104-B(4):444–451


The Bone & Joint Journal
Vol. 103-B, Issue 6 Supple A | Pages 165 - 170
1 Jun 2021
Larson DJ Rosenberg JH Lawlor MA Garvin KL Hartman CW Lyden E Konigsberg BS

Aims. Stemmed tibial components are frequently used in revision total knee arthroplasty (TKA). The purpose of this study was to evaluate patient satisfaction, overall pain, and diaphyseal tibial pain in patients who underwent revision TKA with cemented or uncemented stemmed tibial components. Methods. This is a retrospective cohort study involving 110 patients with revision TKA with cemented versus uncemented stemmed tibial components. Patients who underwent revision TKA with stemmed tibial components over a 15-year period at a single institution with at least two-year follow-up were assessed. Pain was evaluated through postal surveys. There were 63 patients with cemented tibial stems and 47 with uncemented stems. Radiographs and Knee Society Scores were used to evaluate for objective findings associated with pain or patient dissatisfaction. Postal surveys were analyzed using Fisher’s exact test and the independent-samples t-test. Logistic regression was used to adjust for age, sex, and preoperative bone loss. Results. No statistically significant differences in stem length, operative side, or indications for revision were found between the two cohorts. Tibial pain at the end of the stem was present in 25.3% (16/63) of cemented stems and 25.5% (12/47) of uncemented stems (p = 1.000); 74.6% (47/63) of cemented patients and 78.7% (37/47) of uncemented patients were satisfied following revision TKA (p = 0.657). Conclusion. There were no differences in patient satisfaction, overall pain, and diaphyseal tibial pain in cemented and uncemented stemmed tibial components in revision TKA. Patient factors, rather than implant selection and surgical technique, likely play a large role in the presence of postoperative pain. Stemmed tibial components have been shown to be a possible source of pain in revision TKA. There is no difference in patient satisfaction or postoperative pain with cemented or uncemented stemmed tibial components in revision TKA. Cite this article: Bone Joint J 2021;103-B(6 Supple A):165–170


The Bone & Joint Journal
Vol. 104-B, Issue 10 | Pages 1118 - 1125
4 Oct 2022
Suda Y Hiranaka T Kamenaga T Koide M Fujishiro T Okamoto K Matsumoto T

Aims. A fracture of the medial tibial plateau is a serious complication of Oxford mobile-bearing unicompartmental knee arthroplasty (OUKA). The risk of these fractures is reportedly lower when using components with a longer keel-cortex distance (KCDs). The aim of this study was to examine how slight varus placement of the tibial component might affect the KCDs, and the rate of tibial plateau fracture, in a clinical setting. Methods. This retrospective study included 255 patients who underwent 305 OUKAs with cementless tibial components. There were 52 males and 203 females. Their mean age was 73.1 years (47 to 91), and the mean follow-up was 1.9 years (1.0 to 2.0). In 217 knees in 187 patients in the conventional group, tibial cuts were made orthogonally to the tibial axis. The varus group included 88 knees in 68 patients, and tibial cuts were made slightly varus using a new osteotomy guide. Anterior and posterior KCDs and the origins of fracture lines were assessed using 3D CT scans one week postoperatively. The KCDs and rate of fracture were compared between the two groups. Results. Medial tibial fractures occurred after surgery in 15 patients (15 OUKAs) in the conventional group, but only one patient (one OUKA) had a tibial fracture after surgery in the varus group. This difference was significant (6.9% vs 1.1%; p = 0.029). The mean posterior KCD was significantly shorter in the conventional group (5.0 mm (SD 1.7)) than in the varus group (6.1 mm (SD 2.1); p = 0.002). Conclusion. In OUKA, the distance between the keel and posterior tibial cortex was longer in our patients with slight varus alignment of the tibial component, which seems to decrease the risk of postoperative tibial fracture. Cite this article: Bone Joint J 2022;104-B(10):1118–1125


The Journal of Bone & Joint Surgery British Volume
Vol. 72-B, Issue 2 | Pages 252 - 258
1 Mar 1990
Albrektsson B Ryd L Carlsson L Freeman M Herberts P Regner L Selvik G

We studied the effect of a metal tray with an intramedullary stem on the micromotion of the tibial component in total knee arthroplasty. Of 32 uncemented Freeman-Samuelson knee arthroplasties performed in London and Gothenburg, nine had a metal backing and stem added to the tibial component. Micromotion of the tibial components, expressed as migration and inducible displacement, was analysed using roentgen stereophotogrammetric analysis up to two years follow-up. The addition of a metal back and a 110 mm stem to the standard polyethylene component significantly reduced both migration over two years and inducible displacement


The Bone & Joint Journal
Vol. 102-B, Issue 2 | Pages 170 - 176
1 Feb 2020
Bernthal NM Burke ZDC Hegde V Upfill-Brown A Chen CJ Hwang R Eckardt JJ

Aims. We aimed to examine the long-term mechanical survivorship, describe the modes of all-cause failure, and identify risk factors for mechanical failure of all-polyethylene tibial components in endoprosthetic reconstruction. Methods. This is a retrospective database review of consecutive endoprosthetic reconstructions performed for oncological indications between 1980 and 2019. Patients with all-polyethylene tibial components were isolated and analyzed for revision for mechanical failure. Outcomes included survival of the all-polyethylene tibial component, revision surgery categorized according to the Henderson Failure Mode Classification, and complications and functional outcome, as assessed by the Musculoskeletal Tumor Society (MSTS) score at the final follow-up. Results. A total of 278 patients were identified with 289 all-polyethylene tibial components. Mechanical survival was 98.4%, 91.1%, and 85.2% at five, ten and 15 years, respectively. A total of 15 mechanical failures were identified at the final follow-up. Of the 13 all-polyethylene tibial components used for revision of a previous tibial component, five (38.5%) failed mechanically. Younger patients (< 18 years vs > 18 years; p = 0.005) and those used as revision components (p < 0.001) had significantly increased rates of failure. Multivariate logistic regression modelling showed revision status to be a positive risk factor for failure (odds ratio (OR) 19.498, 95% confidence interval (CI) 4.598 to 82.676) and increasing age was a negative risk factor for failure (OR 0.927, 95% CI 0.872 to 0.987). Age-stratified risk analysis showed that age > 24 years was no longer a statistically significant risk factor for failure. The final mean MSTS score for all patients was 89% (8.5% to 100.0%). Conclusion. The long-term mechanical survivorship of all-polyethylene tibial components when used for tumour endoprostheses was excellent. Tumour surgeons should consider using these components for their durability and the secondary benefits of reduced cost and ease of removal and revision. However, caution should be taken when using all-polyethylene tibial components in the revision setting as a significantly higher rate of mechanical failure was seen in this group of patients. Cite this article: Bone Joint J. 2020;102-B(2):170–176


Bone & Joint Research
Vol. 11, Issue 5 | Pages 252 - 259
1 May 2022
Cho BW Kang K Kwon HM Lee W Yang IH Nam JH Koh Y Park KK

Aims. This study aimed to identify the effect of anatomical tibial component (ATC) design on load distribution in the periprosthetic tibial bone of Koreans using finite element analysis (FEA). Methods. 3D finite element models of 30 tibiae in Korean women were created. A symmetric tibial component (STC, NexGen LPS-Flex) and an ATC (Persona) were used in surgical simulation. We compared the FEA measurements (von Mises stress and principal strains) around the stem tip and in the medial half of the proximal tibial bone, as well as the distance from the distal stem tip to the shortest anteromedial cortical bone. Correlations between this distance and FEA measurements were then analyzed. Results. The distance from the distal stem tip to the shortest cortical bone showed no statistically significant difference between implants. However, the peak von Mises stress around the distal stem tip was higher with STC than with ATC. In the medial half of the proximal tibial bone: 1) the mean von Mises stress, maximum principal strain, and minimum principal strain were higher with ATC; 2) ATC showed a positive correlation between the distance and mean von Mises stress; 3) ATC showed a negative correlation between the distance and mean minimum principal strain; and 4) STC showed no correlation between the distance and mean measurements. Conclusion. Implant design affects the load distribution on the periprosthetic tibial bone, and ATC can be more advantageous in preventing stress-shielding than STC. However, under certain circumstances with short distances, the advantage of ATC may be offset. Cite this article: Bone Joint Res 2022;11(5):252–259


The Bone & Joint Journal
Vol. 103-B, Issue 5 | Pages 855 - 863
1 May 2021
Koster LA Meinardi JE Kaptein BL Van der Linden - Van der Zwaag E Nelissen RGHH

Aims. The objective of this study was to compare the two-year migration pattern and clinical outcomes of a total knee arthroplasty (TKA) with an asymmetrical tibial design (Persona PS) and a well-proven TKA with a symmetrical tibial design (NexGen LPS). Methods. A randomized controlled radiostereometric analysis (RSA) trial was conducted including 75 cemented posterior-stabilized TKAs. Implant migration was measured with RSA. Maximum total point motion (MTPM), translations, rotations, clinical outcomes, and patient-reported outcome measures (PROMs) were assessed at one week postoperatively and at three, six, 12, and 24 months postoperatively. Results. A linear mixed-effect model using RSA data of 31 asymmetrical and 38 symmetrical TKAs did not show a difference in mean MTPM migration pattern of the tibial or femoral components. Mean tibial component MTPM at two years postoperative of the asymmetrical TKA design was 0.93 mm and 1.00 mm for the symmetrical design. For the femoral component these values were 1.04 mm and 1.14 mm, respectively. No significant differences were observed in other migration parameters or in clinical and PROM measurements. Conclusion. The TKA design with an asymmetrical tibial component has comparable component migration with the proven TKA with a symmetrical tibial component. This suggests the risk of long-term aseptic loosening of the two designs is comparable. Cite this article: Bone Joint J 2021;103-B(5):855–863


Bone & Joint Research
Vol. 8, Issue 3 | Pages 126 - 135
1 Mar 2019
Sekiguchi K Nakamura S Kuriyama S Nishitani K Ito H Tanaka Y Watanabe M Matsuda S

Objectives. Unicompartmental knee arthroplasty (UKA) is one surgical option for treating symptomatic medial osteoarthritis. Clinical studies have shown the functional benefits of UKA; however, the optimal alignment of the tibial component is still debated. The purpose of this study was to evaluate the effects of tibial coronal and sagittal plane alignment in UKA on knee kinematics and cruciate ligament tension, using a musculoskeletal computer simulation. Methods. The tibial component was first aligned perpendicular to the mechanical axis of the tibia, with a 7° posterior slope (basic model). Subsequently, coronal and sagittal plane alignments were changed in a simulation programme. Kinematics and cruciate ligament tensions were simulated during weight-bearing deep knee bend and gait motions. Translation was defined as the distance between the most medial and the most lateral femoral positions throughout the cycle. Results. The femur was positioned more medially relative to the tibia, with increasing varus alignment of the tibial component. Medial/lateral (ML) translation was smallest in the 2° varus model. A greater posterior slope posteriorized the medial condyle and increased anterior cruciate ligament (ACL) tension. ML translation was increased in the > 7° posterior slope model and the 0° model. Conclusion. The current study suggests that the preferred tibial component alignment is between neutral and 2° varus in the coronal plane, and between 3° and 7° posterior slope in the sagittal plane. Varus > 4° or valgus alignment and excessive posterior slope caused excessive ML translation, which could be related to feelings of instability and could potentially have negative effects on clinical outcomes and implant durability. Cite this article: K. Sekiguchi, S. Nakamura, S. Kuriyama, K. Nishitani, H. Ito, Y. Tanaka, M. Watanabe, S. Matsuda. Bone Joint Res 2019;8:126–135. DOI: 10.1302/2046-3758.83.BJR-2018-0208.R2


Bone & Joint Research
Vol. 7, Issue 3 | Pages 226 - 231
1 Mar 2018
Campi S Mellon SJ Ridley D Foulke B Dodd CAF Pandit HG Murray DW

Objectives. The primary stability of the cementless Oxford Unicompartmental Knee Replacement (OUKR) relies on interference fit (or press fit). Insufficient interference may cause implant loosening, whilst excessive interference could cause bone damage and fracture. The aim of this study was to identify the optimal interference fit by measuring the force required to seat the tibial component of the cementless OUKR (push-in force) and the force required to remove the component (pull-out force). Materials and Methods. Six cementless OUKR tibial components were implanted in 12 new slots prepared on blocks of solid polyurethane foam (20 pounds per cubic foot (PCF), Sawbones, Malmo, Sweden) with a range of interference of 0.1 mm to 1.9 mm using a Dartec materials testing machine HC10 (Zwick Ltd, Herefordshire, United Kingdom) . The experiment was repeated with cellular polyurethane foam (15 PCF), which is a more porous analogue for trabecular bone. Results. The push-in force progressively increased with increasing interference. The pull-out force was related in a non-linear fashion to interference, decreasing with higher interference. Compared with the current nominal interference, a lower interference would reduce the push-in forces by up to 45% (p < 0.001 One way ANOVA) ensuring comparable (or improved) pull-out forces (p > 0.05 Bonferroni post hoc test). With the more porous bone analogue, although the forces were lower, the relationship between interference and push-in and pull-out force were similar. Conclusions. This study suggests that decreasing the interference fit of the tibial component of the cementless OUKR reduces the push-in force and can increase the pull-out force. An optimal interference fit may both improve primary fixation and decrease the risk of fracture. Cite this article: S. Campi, S. J. Mellon, D. Ridley, B. Foulke, C. A. F. Dodd, H. G. Pandit, D. W. Murray. Optimal interference of the tibial component of the cementless Oxford Unicompartmental Knee Replacement. Bone Joint Res 2018;7:226–231. DOI: 10.1302/2046-3758.73.BJR-2017-0193.R1


Bone & Joint Open
Vol. 5, Issue 1 | Pages 20 - 27
17 Jan 2024
Turgeon TR Vasarhelyi E Howard J Teeter M Righolt CH Gascoyne T Bohm E

Aims. A novel enhanced cement fixation (EF) tibial implant with deeper cement pockets and a more roughened bonding surface was released to market for an existing total knee arthroplasty (TKA) system.This randomized controlled trial assessed fixation of the both the EF (ATTUNE S+) and standard (Std; ATTUNE S) using radiostereometric analysis. Methods. Overall, 50 subjects were randomized (21 EF-TKA and 23 Std-TKA in the final analysis), and had follow-up visits at six weeks, and six, 12, and 24 months to assess migration of the tibial component. Low viscosity bone cement with tobramycin was used in a standardized fashion for all subjects. Patient-reported outcome measure data was captured at preoperative and all postoperative visits. Results. The patient cohort mean age was 66 years (SD seven years), 59% were female, and the mean BMI was 32 kg/m. 2. (SD 6 kg/m. 2. ). Mean two-year subsidence of the EF-TKA was 0.056 mm (95% confidence interval (CI) 0.025 to 0.086) versus 0.006 mm (95% CI -0.029 to 0.040) for the Std-TKA, and the two-year maximum total point motion (MTPM) was 0.285 mm (95% upper confidence limit (UCL) ≤ 0.363) versus 0.346 mm (95% UCL ≤ 0.432), respectively, for a mean difference of -0.061 mm (95% CI -0.196 to 0.074). Inducible displacement also did not differ between groups. The MTPMs between 12 and 24 months for each group was below the published threshold of 0.2 mm for predicting early aseptic loosening (p < 0.001 and p = 0.001, respectively). Conclusion. Both the enhanced fixation and the standard tibial implant design showed fixation with a predicted low risk of long-term aseptic loosening. Cite this article: Bone Jt Open 2024;5(1):20–27


The Bone & Joint Journal
Vol. 100-B, Issue 12 | Pages 1579 - 1584
1 Dec 2018
Turgeon TR Gascoyne TC Laende EK Dunbar MJ Bohm ER Richardson CG

Aims. The introduction of a novel design of total knee arthroplasty (TKA) must achieve outcomes at least as good as existing designs. A novel design of TKA with a reducing radius of the femoral component and a modified cam-post articulation has been released and requires assessment of the fixation to bone. Radiostereometric analysis (RSA) of the components within the first two postoperative years has been shown to be predictive of medium- to long-term fixation. The aim of this study was to assess the stability of the tibial component of this system during this period of time using RSA. Patients and Methods. A cohort of 30 patients underwent primary, cemented TKA using the novel posterior stabilized fixed-bearing (ATTUNE) design. There was an even distribution of men and women (15:15). The mean age of the patients was 64 years (sd 8) at the time of surgery; their mean body mass index (BMI) was 35.4 kg/m2 (sd 7.9). RSA was used to assess the stability of the tibial component at 6, 12, and 24 months compared with a six-week baseline examination. Patient-reported outcome measures were also assessed. Results. The mean maximum total point motion (MTPM) of the tibial component between 12 and 24 months postoperatively was 0.08 mm (sd 0.08), which is well below the published threshold of 0.2 mm (p < 0.001). Patient-reported outcome measures consistently improved. Conclusion. The tibial component of this novel design of TKA showed stability between assessment 12 and 24 months postoperatively, suggesting an acceptably low risk of medium- to long-term failure due to aseptic loosening


Bone & Joint Research
Vol. 6, Issue 11 | Pages 623 - 630
1 Nov 2017
Suh D Kang K Son J Kwon O Baek C Koh Y

Objectives. Malalignment of the tibial component could influence the long-term survival of a total knee arthroplasty (TKA). The object of this study was to investigate the biomechanical effect of varus and valgus malalignment on the tibial component under stance-phase gait cycle loading conditions. Methods. Validated finite element models for varus and valgus malalignment by 3° and 5° were developed to evaluate the effect of malalignment on the tibial component in TKA. Maximum contact stress and contact area on a polyethylene insert, maximum contact stress on patellar button and the collateral ligament force were investigated. Results. There was greater total contact stress in the varus alignment than in the valgus, with more marked difference on the medial side. An increase in ligament force was clearly demonstrated, especially in the valgus alignment and force exerted on the medial collateral ligament also increased. Conclusion. These results highlight the importance of accurate surgical reconstruction of the coronal tibial alignment of the knee joint. Varus and valgus alignments will influence wear and ligament stability, respectively in TKA. Cite this article: D-S. Suh, K-T. Kang, J. Son, O-R. Kwon, C. Baek, Y-G. Koh. Computational study on the effect of malalignment of the tibial component on the biomechanics of total knee arthroplasty: A Finite Element Analysis. Bone Joint Res 2017;6:623–630. DOI: 10.1302/2046-3758.611.BJR-2016-0088.R2


The Bone & Joint Journal
Vol. 99-B, Issue 12 | Pages 1596 - 1602
1 Dec 2017
Dunbar MJ Laende EK Collopy D Richardson CG

Aims. Hydroxyapatite coatings for uncemented fixation in total knee arthroplasty can theoretically provide a long-lasting biological interface with the host bone. The objective of this study was to test this hypothesis with propriety hydroxyapatite, peri-apatite, coated tibial components using component migration measured with radiostereometric analysis over two years as an indicator of long-term fixation. Patients and Methods. A total of 29 patients at two centres received uncemented PA-coated tibial components and were followed for two years with radiostereometric analysis exams to quantify the migration of the component. Results. While there was significant variation in individual migration patterns, the overall migration of the tibial component in the study group demonstrated a pattern of initial migration followed by stabilisation after one year, with mean maximum total point motion (MTPM) of 0.02 mm (standard deviation (. sd. ) 0.20) between one and two years post-operatively. The direction of greatest motion was subsidence, which stabilised at three months post-operatively (mean translation of 0.21 mm, . sd. 0.40). Conclusion. The tibial component migration pattern of stabilisation in the second post-operative year is indicative of successful long-term fixation for this PA-coated tibial component. Cite this article: Bone Joint J 2017;99-B:1596–1602


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_2 | Pages 29 - 29
1 Mar 2021
Dalal S Aminake G Chandratreya A Kotwal R
Full Access

Abstract. Introduction. Long term survivorship in Total Knee Arthroplasty is significantly dependent on prosthesis alignment. The aim of this study was to determine, compare and analyse the coronal alignment of the tibial component of a single implant system using 3 different techniques. Method. Retrospective study of cases from a prospectively collected database. Radiological assessment included measurement of the coronal alignment of tibial components of total knee arthroplasties, and its deviation from the mechanical axis. A comparison study of intramedullary, extramedullary and tibial crest alignment methods was performed. Results. 66 consecutive patients (3 groups of 22 each). Mean BMI was 26. The mean angle of deviation from the mechanical axis was significantly lesser (p< 0.05) in the Tibial crest alignment group patients compared to the other 2 groups. Moreover, the number of outliers (+/-3 degrees) were 2 and 4 in the intra and extramedullary group, whereas there were none in the tibial crest group. The inter and intraclass correlation coefficient was 0.8 and 0.9 respectively. Conclusion. The Tibial Crest Alignment Technique is an effective technique to produce consistent results to achieve optimal coronal alignment of the tibial component in TKA, even in patients with high BMI. Declaration of Interest. (b) declare that there is no conflict of interest that could be perceived as prejudicing the impartiality of the research reported:I declare that there is no conflict of interest that could be perceived as prejudicing the impartiality of the research project


Abstract. Introduction. Cementless fixation of Oxford Unicompartmental Knee Replacements (UKRs) is an alternative to cemented fixation, however, it is unknown whether cementless fixation is as good long-term. This study aimed to compare primary and long-term fixation of cemented and cementless Oxford UKRs using radiostereometric analysis (RSA). Methodology. Twenty-nine patients were randomised to receive cemented or cementless Oxford UKRs and followed for ten years. Differences in primary fixation and long-term fixation of the tibial components (inferred from 0/3/6-month and 6-month/1-year/2-year/5-year/10-year migration, respectively) were analysed using RSA and radiolucencies were assessed on radiographs. Migration rates were determined by linear regression and clinical outcomes measured using the Oxford Knee Score (OKS). Results. Preliminary analysis of Maximum Total Point Motion (MTPM) indicated cementless tibial components undergo significantly more migration than cemented components during the first 6 months (1.6mm/year, SD=0.92 versus 1.3mm/year, SD=1.1, p<0.001). Cementless migration was predominantly subsidence inferiorly (Mean=0.51mm/year, SD=0.29, p<0.001) and posteriorly (0.13mm/year, SD=0.21, p=0.03). Contrastingly, from 6 months to 10 years cemented components migrated significantly (MTPM=0.039mm/year, SD=0.11, p=0.04) whereas cementless components did not (MTPM=0.002mm/year, SD=0.02, p=0.744). Radiolucent lines occurred more frequently below cemented (10/13) than cementless (4/16) tibial components, but radiolucencies did not correlate with differences in migration or OKS. There was no significant difference in OKS between cemented and cementless. Conclusion. These results suggest that cementless tibial components migrate more than cemented before achieving primary fixation. However, long-term fixation of cementless tibial components appears to be as good, if not better, than cemented with the benefit of fewer radiolucent lines


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_7 | Pages 85 - 85
1 Jul 2022
Rahman A Heath D Mellon S Murray D
Full Access

Abstract. Introduction. In cementless UKR, primary fixation of the tibial component is achieved by press-fitting a keel (i.e. with interference) into a vertical slot cut into the proximal tibia. This may adversely affect the structural integrity of surrounding bone. Early post-operative peri-prosthetic tibial fractures are 7x more common in very small knees, but the aetiology of these fractures is unknown - such sizes are rarely used in the UK but more common in Asian populations. This study explores the effect of keel-related features in fracture risk of these very small tibias. Method. This in vitro study compares the effect of keel and slot depth (standard vs 33% shallower vs nil) and loading position (anterior/posterior gait range limits: mid-tibia vs 8mm posterior) on fracture load and path. 3D-printed titanium components were implanted using surgical instrumentation/technique, in bone-analogue foam machined to a CT-reconstructed very small tibia which subsequently experienced a peri-prosthetic fracture. Results. Introducing a standard slot reduces load-to-fracture by 50% (1421N-vs-710N, p<0.0001). Press-fitting a standard keel further reduces load-to-fracture by 40% (710N-vs-423N, p=0.0001). A shallower slot/keel increases load-to-fracture substantially (slot: 27% increase, 904N-vs-710N p=0.0003, slot+keel: 60% increase, 683N-vs-423N p=0.0004). Deeper keels fractured more vertically (current 8.2° vs shallow 15.5° vs nil 21°, degrees-to-vertical, p<0.0001). There was no difference caused by loading position. Conclusion. In very small tibias, a standard cementless keel significantly weakens the bone and may contribute to fractures. Therefore, decreasing interference or using a shallower keel should decrease the risk of fracture, although it might compromise fixation


The Bone & Joint Journal
Vol. 105-B, Issue 10 | Pages 1099 - 1107
1 Oct 2023
Henry JK Shaffrey I Wishman M Palma Munita J Zhu J Cody E Ellis S Deland J Demetracopoulos C

Aims. The Vantage Total Ankle System is a fourth-generation low-profile fixed-bearing implant that has been available since 2016. We aimed to describe our early experience with this implant. Methods. This is a single-centre retrospective review of patients who underwent primary total ankle arthroplasty (TAA) with a Vantage implant between November 2017 and February 2020, with a minimum of two years’ follow-up. Four surgeons contributed patients. The primary outcome was reoperation and revision rate of the Vantage implant at two years. Secondary outcomes included radiological alignment, peri-implant complications, and pre- and postoperative patient-reported outcomes. Results. There were 168 patients (171 ankles) included with a mean follow-up of 2.81 years (2 to 4.6) and mean age of 63.0 years (SD 9.4). Of the ten ankles with implant failure (5.8%), six had loosening of the tibial component. In the remaining four failed implants, one was due to periprosthetic joint infection (PJI), one was due to loosening of the talar component, and two were due to loosening of both the tibial and talar components. Seven patients underwent reoperation: irrigation and debridement for superficial infection (n = 4); bone grafting for cysts (n = 2); and open reduction internal fixation (n = 1). Asymptomatic peri-implant lucency/subsidence occurred in 20.1% of ankles, with the majority involving the tibial component (n = 25). There were statistically significant improvements in PROMs in all domains. Conclusion. Short-term results of this implant demonstrate early survival comparable to the reported survivorship of similar low-profile, non-stemmed implants. Radiological lucency occurred more commonly at the tibial component, and revisions occurred primarily due to loosening of the tibial component. Further research is needed to evaluate longer-term survivorship. Cite this article: Bone Joint J 2023;105-B(10):1099–1107


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_7 | Pages 84 - 84
1 Jul 2022
Rahman A Dangas K Mellon S Murray D
Full Access

Abstract. Introduction. After remodelling, loss of bone density beside the keel of cementless UKR tibial components has been observed as a potential cause of concern. How this affects patient-reported outcomes, and further clinical implications, is unclear. This study aims to assess the effect of cementless UKR implantation on tibial bone density, and to explore its relationship to patient demographics and outcomes. Method. This prospective study assesses 115 anterior-posterior radiographs from cementless UKR postoperatively and five years after surgery. Grey values from nine regions around each keel were collected and standardised to enable inter-radiograph comparison. Change between the post-operative and 5-year radiographs (indicating bone density) was calculated, and effect on 5-year patient demographics and pain and functional outcomes was assessed. Repeat measurements were performed by two operators to assess reliability. Results. There was excellent inter-operator correlation. There was increased bone density directly below the keel (9.1% vs 3.3%: p<0.0001), and reduced density beside the keel (−5.9% vs -1.0%, p<0.0001); comparisons to adjacent regions. Overall remodelling was significantly greater in smaller tibias (p=0.006), and females (p=0.01). Remodelling was unrelated to outcomes (OKS, ICOAP-A/B, TAS), age, and BMI. Conclusion. Remodelling patterns suggest increased loading below and decreased loading adjacent to the tibial keel. Remodelling is greater in smaller tibias and females. Remodelling is not related to any patient-reported pain or function five years after surgery, suggesting that remodelling is successful in removing any mechanical source of bone pain. Therefore, clinicians viewing such remodelling patterns can ignore them as they are of no consequence


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_3 | Pages 3 - 3
1 Apr 2018
Trieb K
Full Access

Introduction. Today TKR is considered one of the most successful operative procedures in orthopedic surgery. Nevertheless, failure rates of 2 – 10% depending on the length of the study and the design are still reported. This provides evidence for further development in knee arthroplasty. Particularly the oxide ceramics used now in THA show major advantages due to their excellent tribological properties, their significantly reduced third-body wear as well as their high corrosion resistance. A further advantage of ceramic materials is their potential use in patients with metal allergy. Metallic wear induces immunological reactions resulting in hypersensitivity, pain, osteolysis and implant loosening. The purpose of our study was to examine the safety of the tibial component of a novel all-ceramic TKR. Materials and Methods. We tested the tibial components of the primary knee implant BPK-S Integration Ceramic. Both the tibial and the femoral component consist of BIOLOX®delta ceramic The standards ISO 14879-1 and ASTM F1800-07 describe the test set-up for the experimental fatigue strength testing of tibial components from knee implants. We conducted the testing with a significantly increased maximum load of 5,300 N (900 N are required). A final burst strength test was carried out after the fatigue load testing in the same embedding and with the same test set-up. Results. No specimen failed during fatigue load testing. The subsequent post-fatigue burst strength testing showed a maximum strength against fracture of at least 9.7 kN for size 3 and at least 12.1 kN for size 6. Discussion. The good results of the strength testing of the tibial component of the BPK-S Integration Ceramic tibial plateau supported the good initial clinical outcome without any implant specific complications of this knee design. Further clinical studies have to show if this design fulfills the high expectations over long periods of time


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 10 | Pages 1466 - 1470
1 Oct 2010
Didden K Luyckx T Bellemans J Labey L Innocenti B Vandenneucker H

The biomechanics of the patellofemoral joint can become disturbed during total knee replacement by alterations induced by the position and shape of the different prosthetic components. The role of the patella and femoral trochlea has been well studied. We have examined the effect of anterior or posterior positioning of the tibial component on the mechanisms of patellofemoral contact in total knee replacement. The hypothesis was that placing the tibial component more posteriorly would reduce patellofemoral contact stress while providing a more efficient lever arm during extension of the knee. We studied five different positions of the tibial component using a six degrees of freedom dynamic knee simulator system based on the Oxford rig, while simulating an active knee squat under physiological loading conditions. The patellofemoral contact force decreased at a mean of 2.2% for every millimetre of posterior translation of the tibial component. Anterior positions of the tibial component were associated with elevation of the patellofemoral joint pressure, which was particularly marked in flexion > 90°. From our results we believe that more posterior positioning of the tibial component in total knee replacement would be beneficial to the patellofemoral joint


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 1 | Pages 45 - 49
1 Jan 2007
Ikeuchi M Yamanaka N Okanoue Y Ueta E Tani T

We prospectively assessed the benefits of using either a range-of-movement technique or an anatomical landmark method to determine the rotational alignment of the tibial component during total knee replacement. We analysed the cut proximal tibia intraoperatively, determining anteroposterior axes by the range-of-movement technique and comparing them with the anatomical anteroposterior axis. We found that the range-of-movement technique tended to leave the tibial component more internally rotated than when anatomical landmarks were used. In addition, it gave widely variable results (mean 7.5°; 2° to 17°), determined to some extent by which posterior reference point was used. Because of the wide variability and the possibilities for error, we consider that it is inappropriate to use the range-of-movement technique as the sole method of determining alignment of the tibial component during total knee replacement


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_2 | Pages 130 - 130
1 Jan 2016
Kuriyama S Ishikawa M Nakamura S Furu M Ito H Matsuda S
Full Access

Introduction. Malrotation of the tibial component would lead to various complications after total knee arthroplasty (TKA) such as improper joint kinematics, patellofemoral instability, or excessive wear of polyethylene. However, despite reports of internal rotation of the tibial component being associated with more severe pain or stiffness than external rotation, the biomechanical reasons remain largely unknown. In this study, we used a musculoskeletal computer model to simulate a squat (0°–130°–0° flexion) and analyzed the effects of malrotated tibial component on lateral and medial collateral ligament (LCL and MCL) tensions, tibiofemoral and patellofemoral contact stresses, during the weight-bearing deep knee flexion. Materials and Methods. A musculoskeletal model, replicating the dynamic quadriceps-driven weight-bearing knee flexion in previous cadaver studies, was simulated with a posterior cruciate-retaining TKA. The model included tibiofemoral and patellofemoral contact, passive soft tissue and active muscle elements. The soft tissues were modeled as nonlinear springs using previously reported stiffness parameters, and the bony attachments were also scaled to some cadaver reports. The neutral rotational alignment of the femoral and tibial components was aligned according to the femoral epicondylar axis and the tibial anteroposterior axis, respectively. Knee kinematics and ligament tensions were computed during a squat for malrotated conditions of the tibial component. The tibial rotational alignments were changed from 15° external rotation to 15° internal rotation in 5° increments. The MCL and LCL tensions, the tibiofemoral and patellofemoral contact stresses were compared among the knees with different rotational alignment. Results. For the MCL, the neutral rotated tibial components caused a maximum tension of 67.3 N. However, the 15° internally rotated tibial components increased tensions to 285.2N as a maximum tension [Fig.1]. By contrast, with external rotation of the tibial component, the MCL tensions increased only a small amount. The LCL tension also increased but up to less than half of the MCL value [Fig.2]. The tibiofemoral and patellofemoral contact stresses increased because of a decreased contact area [Fig.3]. Discussion and Conclusion: In this computer simulation, excessive internal rotation in the tibial component increased MCL tensions and patellofemoral and tibiofemoral contact stresses. The current study suggests that increased MCL tensions and patellofemoral and tibiofemoral contact stresses caused by a malrotated tibial component could be one cause of patient complaints and polyethylene problems after TKA


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_6 | Pages 105 - 105
1 Mar 2017
Yamazaki T Kamei R Tomita T Yoshikawa H Sugamoto K
Full Access

Purpose. To achieve 3D kinematic analysis of total knee arthroplasty (TKA), 2D/3D registration techniques, which use X-ray fluoroscopic images and computer aided design model of the knee implants, have been applied to clinical cases. However, most conventional methods have needed time-consuming and labor-intensive manual operations in some process. In particular, for the 3D pose estimation of tibial component model from X-ray images, these manual operations were carefully performed because the pose estimation of symmetrical tibial component get severe local minima rather than that of unsymmetrical femoral component. In this study, therefore, we propose an automated 3D kinematic estimation method of tibial component based on statistical motion model, which is created from previous analyzed 3D kinematic data of TKA. Methods. The used 2D/3D registration technique is based on a robust feature-based (contour-based) algorithm. In our proposed method, a statistical motion model which represents average and variability of joint motion is incorporated into the robust feature-based algorithm, particularly for the pose estimation of tibial component. The statistical motion model is created from previous a lot of analyzed 3D kinematic data of TKA. In this study, a statistical motion model for relative knee motion of the tibial component with respect to the femoral component was created and utilized. Fig. 1 shows each relative knee motion model for six degree of freedom (three translations and three rotations parameter). Thus, after the pose estimation of the femoral component model, 3D pose of the tibial component model is determined by maximum a posteriori (MAP) estimation using the new cost function introduced the statistical motion model. Experimental results. To validate the feasibility and effectiveness of 3D pose estimation for the tibial component using the proposed method, experiments using X-ray fluoroscopic images of 20 TKA patients under the squatting knee motion were performed. For the creation of correct pose (reference data) and the statistical motion model, we used the 3D pose data which were got by carefully applying previous method to the contour images which spurious edges and noises were removed manually. In order to ensure the validity for the statistical motion model of the proposed method, leave-one-out cross validation method was applied. In the 3D pose estimation of tibial component model, for the only first frame, initial guess pose of the model was manually given. For all images except for the first frame, the 3D pose of the model was automatically estimated without manual initial guess pose of the model. To assess the automation performance, the automation rate was calculated, and the rate was defined as the X-ray frame number of satisfying clinical required accuracy (error within 1mm, 1 degree) relative to all X-ray frame number. As results of the experiments, 3D pose of the tibial component model for all X-ray images except for the first frame was full-automatically stably-estimated, and the automation rate was 80.1 %. Conclusions. The proposed method by MAP estimation introduced the statistical motion model was successfully performed, and did not need labor-intensive manual operations for 3D pose estimation of tibial component. For any figures or tables, please contact authors directly (see Info & Metrics tab above).


The Bone & Joint Journal
Vol. 102-B, Issue 8 | Pages 1025 - 1032
1 Aug 2020
Hampton M Mansoor J Getty J Sutton PM

Aims. Total knee arthroplasty is an established treatment for knee osteoarthritis with excellent long-term results, but there remains controversy about the role of uncemented prostheses. We present the long-term results of a randomized trial comparing an uncemented tantalum metal tibial component with a conventional cemented component of the same implant design. Methods. Patients under the age of 70 years with symptomatic osteoarthritis of the knee were randomized to receive either an uncemented tantalum metal tibial monoblock component or a standard cemented modular component. The mean age at time of recruitment to the study was 63 years (50 to 70), 46 (51.1%) knees were in male patients, and the mean body mass index was 30.4 kg/m. 2. (21 to 36). The same cruciate retaining total knee system was used in both groups. All patients received an uncemented femoral component and no patients had their patella resurfaced. Patient outcomes were assessed preoperatively and postoperatively using the modified Oxford Knee Score, Knee Society Score, and 12-Item Short-Form Health Survey questionnaire (SF-12) score. Radiographs were analyzed using the American Knee Society Radiograph Evaluation score. Operative complications, reoperations, or revision surgery were recorded. A total of 90 knees were randomized and at last review 77 knees were assessed. In all, 11 patients had died and two were lost to follow-up. Results. At final review all patients were between 11 and 15 years following surgery. In total, 41 of the knees were cemented and 36 uncemented. There were no revisions in the cemented group and one revision in the uncemented group for fracture. The uncemented group reported better outcomes with both statistically and clinically significant (p = 0.001) improvements in knee-specific Oxford and Knee Society scores compared with the cemented group. The global SF-12 scores demonstrated no statistical difference (p = 0.812). Uncemented knees had better radiological analysis compared with the cemented group (p < 0.001). Conclusion. Use of an uncemented trabecular metal tibial implant can afford better long-term clinical outcomes when compared to cemented tibial components of a matched design. However, both have excellent survivorship up to 15 years after implantation. Cite this article: Bone Joint J 2020;102-B(8):1025–1032


Bone & Joint Research
Vol. 13, Issue 5 | Pages 226 - 236
9 May 2024
Jürgens-Lahnstein JH Petersen ET Rytter S Madsen F Søballe K Stilling M

Aims. Micromotion of the polyethylene (PE) inlay may contribute to backside PE wear in addition to articulate wear of total knee arthroplasty (TKA). Using radiostereometric analysis (RSA) with tantalum beads in the PE inlay, we evaluated PE micromotion and its relationship to PE wear. Methods. A total of 23 patients with a mean age of 83 years (77 to 91), were available from a RSA study on cemented TKA with Maxim tibial components (Zimmer Biomet). PE inlay migration, PE wear, tibial component migration, and the anatomical knee axis were evaluated on weightbearing stereoradiographs. PE inlay wear was measured as the deepest penetration of the femoral component into the PE inlay. Results. At mean six years’ follow-up, the PE wear rate was 0.08 mm/year (95% confidence interval 0.06 to 0.09 mm/year). PE inlay external rotation was below the precision limit and did not influence PE wear. Varus knee alignment did not influence PE wear (p = 0.874), but increased tibial component total translation (p = 0.041). Conclusion. The PE inlay was well fixed and there was no relationship between PE stability and PE wear. The PE wear rate was low and similar in the medial and lateral compartments. Varus knee alignment did not influence PE wear. Cite this article: Bone Joint Res 2024;13(5):226–236


The Bone & Joint Journal
Vol. 95-B, Issue 11_Supple_A | Pages 140 - 143
1 Nov 2013
Scott RD

At least four ways have been described to determine femoral component rotation, and three ways to determine tibial component rotation in total knee replacement (TKR). Each method has its advocates and each has an influence on knee kinematics and the ultimate short and long term success of TKR. Of the four femoral component methods, the author prefers rotating the femoral component in flexion to that amount that establishes a stable symmetrical flexion gap. This judgement is made after the soft tissues of the knee have been balanced in extension. Of the three tibial component methods, the author prefers rotating the tibial component into congruency with the established femoral component rotation with the knee is in extension. This yields a rotationally congruent articulation during weight-bearing and should minimise the torsional forces being transferred through a conforming tibial insert, which could lead to wear to the underside of the tibial polyethylene. Rotating platform components will compensate for any mal-rotation, but can still lead to pain if excessive tibial insert rotation causes soft-tissue impingement. Cite this article: Bone Joint J 2013;95-B, Supple A:140–3


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_I | Pages 122 - 122
1 Mar 2010
Aikawa J Urabe K Fujita M Itoman M
Full Access

Improper rotation of the femoral and tibial components in total knee arthroplasty may leads to various patellofemoral(PF) complications. As for the femoral component, alignment it to the epicondylar axis of the femur has been a widely used method. The tibial component traditionally has been aligned to the medial 1/3 of the tibial tuberosity. However, there is no consensus concerning how to determine the tibial component rotation. The purpose of the current study is to evaluate the influence rotational alignment of tibial component upon PF joint. We divided the cases to two groups. Group A: 41cases 50knees (OA 34cases, RA16cases). The average age was 69.5(35~84). Group B: 30cases 30knees (OA 25 cases, RA 5cases). The average age was 72.6(59~86). In group A, the anteropostrior (AP) axis was defined as the line connecting the medial 1/3 of tibial tuberosity and the center of PCL attachment. In group B, the line connecting the medial edge of patellar tendon attachment and the center of PCL attachment was defined as AP axis. We measured the PF alignment on postoperative X-rays. Tangential radiographs were used to measure the amount of patellar tilt (tilting angle: TA), subluxation and patellar lateral shift (LS). Group A showed that tilting angle 14±4°, lateral shift 0.3±0. These values of group B were 12±5°,0.2±0.1, respectively. In rotation of tibial component, Insall reported that the landmark in front of tibia was medial 1/3 tibial tuberosity. Akagi et,, al reported that the landmark was midial edge of patellar tendon attachment. This study indicated that the latter had better alignment in patellofemoral joint


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_8 | Pages 20 - 20
1 Apr 2017
Meijer M Boerboom A Stevens M Reininga I Janssen D Verdonschot N
Full Access

Background. Trabecular metal (TM) cones are designed to fill up major bone defects in total knee arthroplasty. Tibial components can be implanted in combination with a stem, but it is unclear if this is necessary after reconstruction with a TM cone. Implanting a stem may give extra stability, but may also have negative side-effects. Aim of this study was to investigate stability and strain distribution of a tibial plateau reconstruction with a TM cone while the tibal component is implanted with and without a stem, and whether prosthetic stability was influenced by bone mineral density (BMD). Methods. Tibial revision arthroplasties were performed after reconstruction of an AORI 2B bone defect with TM cones. Plateaus were implanted in seven pairs of cadaveric tibiae; of each pair, one was implanted with and the other without stem. All specimens were loaded to one bodyweight alternating between the medial and lateral tibia plateau. Implant-bone micro motions, bone strains, BMD and correlations were measured and/or calculated. Results. Tibial components without a stem showed only more varus tilt (difference in median 0.14 degrees (P<0.05), but this was not considered clinically relevant. Strain distribution did not differ. BMD had only an effect on the anterior/posterior tilt ρ:-0.72 (P<0.01). Conclusions. Tibial components, with or without a stem, which are implanted after reconstruction of major bone defects using TM cones produce very similar biomechanical conditions in terms of stability and strain distribution. Additional stem extension of the tibial component may not be required after reconstruction of major bone defects using TM cones. Level of evidence. IIb. Disclosures. The department of Orthopaedics, University of Groningen, University Medical Center Groningen has received direct funding from the Anna Fonds (Oegstgeest, NL). Zimmer (Warsaw, IN, USA) has provided the instrumentation and tools for this study. The department of Orthopaedics, University of Groningen, University Medical Center Groningen receives research institutional support from InSpine (Schiedam, NL) and Stryker (Kalamazoo, Mich. USA). One of the authors (ALB) will be and has been paid as a consultant by Zimmer (Warsaw, IN, USA) for purposes of education and training in knee arthroplasty


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_16 | Pages 20 - 20
17 Nov 2023
van Duren B France J Berber R Matar H James P Bloch B
Full Access

Abstract. Objective. Up to 20% of patients can remain dissatisfied following TKR. A proportion of TKRs will need early revision with aseptic loosening the most common. The ATTUNE TKR was introduced in 2011 as successor to its predicate design The PFC Sigma (DePuy Synthes, Warsaw, In). However, following reports of early failures of the tibial component there have been ongoing concerns of increased loosening rates with the ATTUNE TKR. In 2017 a redesigned tibial baseplate (S+) was introduced, which included cement pockets and an increased surface roughness to improve cement bonding. Given the concerns of early tibial loosening with the ATTUNE knee system, this study aimed to compare revision rates and those specific to aseptic loosening of the ATTUNE implant in comparison to an established predicate as well as other implant designs used in a high-volume arthroplasty centre. Methods. The Attune TKR was introduced to our unit in December 2011. Prior to this we routinely used a predicate design with an excellent long-term track record (PFC Sigma) which remains in use. In addition, other designs were available and used as per surgeon preference. Using a prospectively maintained database, we identified 10,202 patients who underwent primary cemented TKR at our institution between 01/04/2003–31/03/2022 with a minimum of 1 year follow-up (Mean 8.4years, range 1–20years): 1) 2406 with ATTUNE TKR (of which 557 were S+) 2) 4652 with PFC TKR 3) 3154 with other cemented designs. All implants were cemented using high viscosity cement. The primary outcome measures were all-cause revision, revision for aseptic loosening, and revision for tibial loosening. Kaplan-Meier survival analysis and Cox regression models were used to compare the primary outcomes between groups. Matched cohorts were selected from the ATTUNE subsets (original and S+) and PFC groups using the nearest neighbor method for radiographic analysis. Radiographs were assessed to compare the presence of radiolucent lines in the Attune S+, standard Attune, and PFC implants. Results. At a mean of 8.4 years follow-up, 308 implants underwent revision equating to 3.58 revisions per 1000 implant-years. The lowest risk of revision was noted in the ATTUNE cohort with 2.98 per 1000-implant-years where the PFC and All Other Implant groups were 3.15 and 4.4 respectively. Aseptic loosing was the most common cause for revision across all cemented implants with 76% (65/88) of involving loosening of the tibia. Survival analysis comparing the ATTUNE cohort to the PFC and All Other Cemented Implant cohorts showed no significant differences for: all-cause revision, aseptic loosening, or tibial loosening (p=0.15,0.77,0.47). Radiolucent lines were detected in 4.6%, 5.8%, and 5.0% of the ATTUNE S+, standard ATTUNE, and PFC groups respectively. These differences were not significant. Conclusion. This study represents the largest non-registry review of the original and S+ ATTUNE TKR in comparison to its predicate design as well as other cemented implants. There appears to be no significant increased revision rate for all-cause revision or aseptic loosening. Radiographic analysis also showed no significant difference in peri-implant radiolucency. It appears that concerns of early loosening may be unfounded. Declaration of Interest. (a) fully declare any financial or other potential conflict of interest


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XL | Pages 88 - 88
1 Sep 2012
Kang J Wazir A Fong A Joshi S Marjoram T Hussein A Reddy R Ashford RU Godsiff S
Full Access

Objectives. All Polyethylene Tibial components in Total Knee Arthroplasty have been in use for some years, studies showing equivalent results to Total Knee Arthroplasty (TKA) with metal-backed Tibial components at 10 years have shown no significant difference between the two on radiostereometric analysis and revision rates[1]. Post operative patient outcome data using standard metal-backed Tibial components is widely reported in the literature. This study is looking at patient outcomes following All-polyethylene tibial component TKA. We hypothesize that using standard patient outcome measures, an improvement comparable with that expected for metal-backed tibial component TKA will be shown with All-polyethylene tibial component TKA. Methods. Between August 2006 and August 2008, 229 all-polyethylene tibial component TKA were implanted at the elective orthopedic unit. The choice of implant was entirely dependent on surgeon's preference. Of the 229 patient's, 225 details were available for review, 27 did not wish to take part in the study and 1 patient died a year following surgery of an unrelated illness. The remaining 197 patients agreed to take part in the study. The patient's were contacted either in person or over the telephone and asked to completed questionnaires for standard knee scoring. These included: the Oxford Knee Score (OKS), the WOMAC Score and the SF-12 Score, both pre-operatively and post operatively. Results. All three Scoring systems used showed an overall improvement post-operatively, as would be reasonably be expected. The results for the OKS, WOMAC and SF-12 all showed an improvement comparable with that expected for metal-backed tibial component TKA. Conclusions. Total Knee Arthroplasty using an all-polyethylene tibial component has been shown with these early results to be a reasonable alternative to metal-backed options offering some advantages. [1,2]


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_5 | Pages 32 - 32
1 Apr 2019
Elkabbani M Haidar F Mohamed T Osman A Tarabichi S
Full Access

Introduction. Tibial component malrotation is one of the commonest causes of pain and stiffness following total knee arthroplasties, however, the assessment of tibial component malrotation on imaging is not a clear-cut. Aim. The objective of this study was to assess tibial component rotation in cases with pain following total knee replacement using MRI with metal artifact reduction technique. Methods. In 35 consecutive patients presented to our clinic between January 2016 and April 2017 with persistent unexplained moderate to severe pain for at least 6 months following total knee arthroplasties after exclusion of infection, MRI evaluation of tibial component rotation using O-MAR technique-(Metal Artifact Reduction for Orthopedic implants) to improve visualization of soft tissue and bone by reducing artifacts caused by metal implants- was done according to the technique of Berger et al. Results. 25 cases showed internal rotation of tibial component, 5 cases showed neutral rotation, 5 cases showed external rotation with presence of abnormal intraarticular fibrous bands. Conclusion. Two main conclusions are obtained from this study:. Firstly: Internal rotation of tibial component must be excluded in all cases of persistent pain following total knee replacement. Secondly: Magnetic resonance imaging with the newly developed metal artifact reduction techniques is a very useful tool in evaluating cases of unexplained pain following total knee replacement


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 4 | Pages 497 - 503
1 Apr 2012
Bercovy M Beldame J Lefebvre B Duron A

This prospective study compares the outcome of 157 hydroxyapatite (HA)-coated tibial components with 164 cemented components in the ROCC Rotating Platform total knee replacement in 291 patients. The mean follow-up was 7.6 years (5.2 to 11). There were two revisions for loosening: one for an HA-coated and one for a cemented tibial component. Radiological evaluation demonstrated no radiolucent lines with the HA-coated femoral components. A total of three HA-coated tibial components exhibited radiolucent lines at three months post-operatively and these disappeared after three further months of protected weight-bearing. With HA-coated components the operating time was shorter (p <  0.006) and the radiological assessment of the tibial interface was more stable (p < 0.01). Using revision for aseptic loosening of the tibial component as the end point, the survival rates at nine years was identical for both groups at 99.1%. Our results suggest that HA-coated components perform at least as well as the same design with cemented components and compare favourably with those of series describing cemented or porous-coated knee replacements, suggesting that fixation of both components with hydroxyapatite is a reliable option in primary total knee replacement


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_6 | Pages 109 - 109
1 Mar 2017
Yokhana S Bergum C Markel D
Full Access

Background. Total knee prostheses are continually being redesigned to improve performance, longevity and closer mimic kinematics of the native knee. Despite continued improvements, all knee implants even those with proven design features, have failures. We identified a cohort of patients with isolated tibial component failures that occurred in a popular and successful knee system. Our purpose was to (1) characterize the observed radiographic failure pattern; (2) investigate the biologic response that may contribute to the failure; and (3) to determine if the failure mechanism was of a biological or a mechanical nature. Methods. Twenty-one knees from 19 patients met the inclusion criteria of having isolated tibial component failure in a commonly used knee implant system. Radiographs from the primary and revision knee surgery were analyzed for implant positioning and failure pattern, respectively. Inflammatory biomarkers IL-1β, IL-6 and TNF-α were available in 16/21 knees and peripheral CD14. +. /16. +. monocytes were measured in 10 of the above mentioned 16 knee revisions. Additionally, white blood cell (WBC) count, erythrocyte sedimentation rate (ESR), and C-reactive protein (CRP) were measured to rule out infection as the cause of the cytokine upregulation. Results. Radiograph findings demonstrated that all of the 21 tibial components were implanted in either neutral or 2–3° varus position, none of the revisions were implanted in valgus (figure 1). All tibias showed obvious radiographic loosening and failed into varus. The inflammatory biomarkers IL-1b, IL-6, & TNF-a were negative. WBC, ESR, CRP were normal. Peripheral CD14+/16+ and total CD16+ monocytesmeasurements were consistent with previous findings of patients with osteoarthritis (figure 2). Conclusions. The findings supported a mechanical failure mechanism rather than that of a wear debris induced inflammatory pattern. The loosening, collapse and debonding from the cement may have been related to the implantation technique, stresses due to rotational freedom of the implant, or patient characteristics/behavior. For any figures or tables, please contact authors directly (see Info & Metrics tab above).


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_4 | Pages 94 - 94
1 Apr 2019
Osman A Tarabichi S Haidar F
Full Access

Introduction. Stiffness postTotal Knee Replacement (TKR) is a common, complex and multifactorial problem. Many reports claim that component mal-rotation plays an important role in this problem. Internal mal-rotation of the tibial component is underestimated among surgeons when compared to femoral internal mal-rotation. We believe the internal mal- rotation of thetibial component can negatively affect the full extension of Knee. We performed an in-vivo study of the impact of tibial internal mal-rotation on knee extension in 31 cases. Method. During TKR, once all bony cuts were completed and flexion/extension gaps balanced, we assessed the degree of knee extension using the trial component in the setting of normaltibial rotation and with varying degrees of internal rotation (13–33°, mean 21.2±4.6°). Intra-operative lateral knee X-ray was done to measure the degree of flexion contracture in both groups. We also compared the degree of flexion contracture between CR and PS spacers. Results. The average degree of knee flexion contracture with normal rotation of the tibial component was 0.7±4.1° (range:-9 to 10), whereas after tibial internal rotation was 7.3±4.6° (range:-1 to 23)(P – value:0.001). The increase in the flexion contracture deformity was higher with PS spacer (7.18±2.61) than with CR spacers (5.22±2.05). Conclusion. The internal mal-rotation of the tibial component limits the ability of the tibia to externally rotate on the femur, thereby limiting full knee extension and leading to flexion contracture


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_34 | Pages 99 - 99
1 Dec 2013
Kawano T Ihara H Tsurusaki S
Full Access

[Introduction]. One of the modern design total knee arthroplasty (TKA) system, the NexGen Legacy posterior-stabilized (LPS) Flex prosthesis, has been in use at our hospital since 2001. Between 2006 and 2011, NexGen LPS-Flex primary TKA were mainly performed in combination with a cemented short-keeled minimally invasive version tibial tray (MIS tibial component) instead of the traditional NexGen stemmed tibial tray. We observed some cases required early revision of isolated tibial component in primary TKA performed in this period. Therefore, our objectives were to report the series of this revision cases and to consider this failure mechanism. [Patients & Methods]. A total of 526 primary TKAs were performed using a NexGen LPS-Flex prosthesis and MIS tibial component during five-year period at our hospital. The mean age was 74 years at the time of the index procedure. We assessed revision rate of this tibial tray in this study and described clinical course of the revision cases. We also examined the clinical and radiographic features which could be associated with the failure. [Results]. The mean duration of follow-up was 2.5 years and there were 13 knees received tibial component revision during this period. Twelve knees were diagnosed with osteoarthritis and one knee with rheumatoid arthritis. The duration between primary TKA and revision averaged at 3.3 years, and the mean age at the second procedure was 67 years. TKAs were performed without applying the tibial central extension stem in all 13 knees, and thick polyethylene insert like 17 or 20 mm were selected for seven and 14 mm for five of 13 knees, that were the typical features on the primary TKA. Postoperative course of all 13 cases was uneventful and 10 of 13 knees achieved deep knee flexion over at 125 degrees. Prerevision radiographs showed characteristic pattern with tibial tray debonding at the cement-implant interface and subsidence into varus and flexion in all 13 knees. In all cases, intraoperative findings revealed a grossly loose tibial component with most of the cement mantle still attached to the bone. No case exhibited signs of macroscopic polyethylene wear and femoral component loosening. [Discussion]. The most common reason for failure of TKA is infection followed by implant loosening, polyethylene wear, and instability. Several studies document survival rates of over 90% up to 20 years with modern TKA designs using a cemented stemmed tibial component. Although failure of the tibial component was more prevalent in some early TKA designs, in recent years, failure of tibial fixation has been a rare cause of revision. Our experience with early aseptic loosening of this tibial component has suggested the low-profile design with no central stem as a cause for accelerated failure. Furthermore, other factors associated with increased this failure could include a thicker insert and postoperative achievement of high flexion


Purpose. Medial tibial condylar fractures (MTCFs) are rare but a serious complication after unicompartmental knee arthroplasty (UKA). The reasons for MTCFs was thought to be associated with the surgical procedures that are the halls for the guide pins, extended cut of the posterior tibial cortex, an incorrect positioning of the tibial keel groove, and an excessive force application when placing the tibial component. However, the relationship between MTCFs and the alignment of the tibial component has not been proven. The purpose of the study was to investigate the effect of the tibial component alignment to the MTCFs using the finite element method (FEM). Materials and Methods. We used three-dimensional (3D) image model of the tibia (Sawbones: Washington, US) on the FEM analysis software (ANSYS Design Space ver. 12, Tokyo, Japan). We measured the bone stresses in the 3D image model of the tibia at the site of the medial metaphyseal cortex and the anterior/posterior cortex. The tibial component was placed 0°, 3°varus, 3°valgus, 6°varus, and 6° valgus relative to the tibial anatomical axis in the coronal plane (Figure 1). In sagittal plane, tibial component was positioned 7° posterior inclination relative to the tibial anatomical axis. And, making an additional vertical groove at the posterior cortex by the extended sagittal saw cut of 2° and 10° posterior inclination, the impact of posterior cortical bone stress was evaluated (Figure 2). A load of 900 N was applied to the center of the tibial component parallel to the tibial axis, the maximum bone stress was subsequently calculated. Furthermore, to evaluate the stress distribution, we calculated the bone mass of the 3D bone model below the tibia component under the various alignment of the tibial component (Figure 3). Results. The bone stress at the medial metaphyseal cortex and the anterior cortex did not change depending on the alignment of the tibial component (Figure 4). When the tibial component was placed varus, the bone stress at the posteiror cortex decreased. By contrast, the valgus position of the tibial component increased the bone stress. An extended sagittal saw cut increased the bone stress depending on the depth of the groove. The bone mass of the tibia below the tibial component decreased as positioning the tibial component valgus. Conclusions. Surgeons should be aware of the potential pitfalls of valgus alignemnt of the tibial component and an extended sagittal saw cut, because this can lead to increased risk of the MTCFs


Orthopaedic Proceedings
Vol. 91-B, Issue SUPP_III | Pages 411 - 412
1 Sep 2009
Chau R Gulati A Pandit HG Beard DJ Gill HS Dodd CAF Simpson DJ Murray DW
Full Access

Purpose: To evaluate the effects of underhanging/overhanging tibial components on clinical outcome following the Oxford unicompartmental knee arthroplasty (UKA), and to identify an acceptable sizing limit. Method: One hundred and sixty-three knees which had undergone the Phase 3 medial Oxford UKA (Biomet, Swindon) were measured. Based on five-year post-operative radiographs, they were divided into groups with tibial component underhang (n=38), none or minimal overhang of less than three millimetres (n=121), and a group with overhang equal to or in excess of three millimetres (n=13). Clinical outcome was assessed by changes in the twelve-question Oxford Knee Score (ΔOKS) and pain score (ΔPS) component (questions 1,4,5,8,9) from pre-operative assessment to five years following surgery. Results: At five years after surgery, ΔOKS was significantly worse in the overhang group compared to both the neutral and underhang groups (p=0.015, and p=0.028 respectively). ΔPS was also shown to be significantly worse between the overhang and the neutral group (p=0.026 respectively). Conclusion: Appropriate sizing of the tibial component is essential to optimise load bearing in total knee arthroplasty. In UKA such sizing is critical due to halving of the bony support for the tibial component and the lack of room for a large stem. Excessive undersizing of the prosthesis may lead to subsidence and loosening, whilst excessive overhanging may cause local soft tissue irritation and pain. This study demonstrates that medial overhang of less than three millimetres for the tibial component is acceptable in the Oxford UKA. Excessive overhang equal to this or more results in significantly worse ΔOKS and ΔPS. However, no difference in the five year ΔOKS and ΔPS was demonstrated between underhang and the other two groups in this study


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_6 | Pages 24 - 24
1 Apr 2018
Adi MM Abdelnasser MK Haidar F Osman A Tarabichi S
Full Access

Introduction. Stiffness post Total Knee Replacement (TKR) is a common, complex and multifactorial problem. Many reports claim that component mal-rotation plays an important role in this problem. Internal mal-rotation of the tibial component is underestimated among surgeons when compared to femoral internal mal-rotation. We believe the internal mal-rotation of the tibial component can negatively affect the full extension of Knee. We performed an in-vivo study of the impact of tibial internal mal-rotation on knee extension in 31 cases. Method. During TKR, once all bony cuts were completed and flexion/extension gaps balanced, we assessed the degree of knee extension using the trial component in the setting of normal tibial rotation and with varying degrees of internal rotation (13–33°, mean 21.2±4.6°). Intra-operative lateral knee X-ray was done to measure the degree of flexion contracture in both groups. We also compared the degree of flexion contracture between CR and PS spacers. Results. The average degree of knee flexion contracture with normal rotation of the tibial component was 0.7±4.1° (range: −9 to 10), whereas after tibial internal rotation was 7.3±4.6° (range: −1 to 23) (P – value:0.001). The increase in the flexion contracture deformity was higher with PS spacer (7.18±2.61) than with CR spacers (5.22±2.05). Conclusion. The internal mal-rotation of the tibial component limits the ability of the tibia to externally rotate on the femur, thereby limiting full knee extension and leading to flexion contracture


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_34 | Pages 28 - 28
1 Dec 2013
Chaudhary M Walker P
Full Access

Tibial component loosening is an important failure mode in unicompartmental knee arthroplasty (UKA) which may be due to the 6–8 mm of bone resection required or the limited surface area. To address component loosening and fixation, a new Early Intervention (EI) design is proposed which reverses the traditional material scheme between femoral and tibial components. That is, the EI design consists of a plastic inlay component for the distal femur and a thin metal plate for the proximal tibia. With this reversed materials scheme, the EI design requires minimal tibial bone resection compared to traditional UKA to preserve the dense and stiff bone in the proximal tibia. This study investigated, by means of finite element (FE) simulations, the potential advantages of a thin metal tibial component compared with traditional UKA tibial components, such as an all-plastic inlay or a metal-backed onlay. We hypothesized that an EI component would produce comparable stress, strain, and strain energy density characteristics to an intact knee and more favorable values than UKA components. Indeed, the finite element results showed that an EI design reduced stresses, strains and strain energy density in the underlying support bone compared to an all-plastic UKA component. Analyzed parameters were similar for an EI and a metal-backed onlay, but the EI component had the advantage of minimal resection of the stiffest bone


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_1 | Pages 142 - 142
1 Jan 2016
Fukushima S Togashi E Sugawara H Narita A Takagi M
Full Access

It is very important for implanting tibial component to prevent bearing dislocation in Oxford UKA. One of the keys is accurate rotational position of tibia. But the problem remains what is accurate rotation of tibia in UKA. Oxford Signature decided the rotation of tibia component from MRI images. We measured the component rotation of tibia using CT after operation. Patients and Methods. 14 patients were operated by Oxford Signature and 11 patients were operated by Microplasty method. Patients were examined by CT 2 or 3 weeks later after operation. We compared component axis of tibia and A-P axis by best fit circle, Akagi's line. Results. In Oxford Signature group, component angle were 7.1 degree external rotation compared with A-P axis by best fit circle and were 3.6 degree external rotation compared with Akagi's line. In Microplasty group, component angle were 8.1 degree external rotation compared with A-P axis by best fit circle and were 3.8 degree external rotation compared with Akagi's line. Discussion. It is difficult to decide accurate position of tibial component for UKA. The A-P axis by best fit circle and Akagi's line are reliable methods for tibial axis in TKA. We examined component axis of Signature Oxford and Microplasty, these were same tendency toward external rotation


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 12 | Pages 1585 - 1593
1 Dec 2008
Henricson A Linder L Nilsson KG

We compared the performance of uncemented trabecular metal tibial components in total knee replacement with that of cemented tibial components in patients younger than 60 years over two years using radiostereophotogrammetric analysis (RSA). A total of 22 consecutive patients (mean age 53 years, 33 to 59, 26 knees) received an uncemented NexGen trabecular metal cruciate-retaining monobloc tibial component and 19 (mean 53 years, 44 to 59, 21 knees) a cemented NexGen Option cruciate-retaining modular tibial component. All the trabecular metal components migrated during the initial three months and then stabilised. The exception was external rotation, which did not stabilise until 12 months. Unlike conventional metal-backed implants which displayed a tilting migration comprising subsidence and lift-off from the tibial tray, most of the trabecular metal components showed subsidence only, probably due to the elasticity of the implant. This pattern of subsidence is regarded as being beneficial for uncemented fixation


The Journal of Bone & Joint Surgery British Volume
Vol. 82-B, Issue 2 | Pages 222 - 227
1 Mar 2000
Fukuoka S Yoshida K Yamano Y

Accurate quantitative measurements of micromovement immediately after operation would be a reliable indicator of the stability of an individual component. We have therefore developed a system for measuring micromovement of the tibial component using three non-contact displacement transducers attached to the tibial cortex during total knee arthroplasty (TKA). Using this system we measured the initial stability in 31 uncemented TKAs. All the tibial components were fixed by a stem and four screws. The initial stability was defined as the amount of displacement when a load of 20 kg was applied. The mean subsidence was 60.7 μm and the mean lift-off was 103.3 μm. We also studied the migration of the tibial component using roentgen stereophotogrammetric analysis (RSA) for up to two years after operation. Most migration occurred during the first six months, after which all prostheses remained stable. We defined migration as the maximum total point motion (MTPM) at two years after operation. The mean migration was 1.29 mm at two years. Our results show that there was a significant correlation between the initial stability and migration (p < 0.05) and emphasise the importance of the initial stability of the tibial component


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_12 | Pages 22 - 22
1 Oct 2018
Saffi M Young SW Spangehl MJ Clarke HD
Full Access

Introduction. Tibial component malrotation is associated with pain, stiffness and altered patellofemoral kinematics in total knee arthroplasty (TKA). However, accurately measuring tibial component rotation following TKA is difficult. Proposed protocols utilizing computed tomography (CT) are not well validated and can be time consuming. This study aimed to; 1) Validate and compare the reproducibility of the Berger (2D-CT) and Mayo (3D-CT) protocols; 2) Validate a simple, and potentially rapid screening measurement using an anatomical distance on 2D axial CT- the Centre of Tibial Tray to Tibial Tubercle (CTTT) distance. Methods. Rotational alignment of 70 TKA patients were evaluated by 3 independent observers using the Berger, and Mayo protocols, which have been previously described, and a new CTTT protocol (Figure 1). The inter and intra-rater interclass correlation coefficients (ICC's), mean difference between measurements and the mean measurement times were calculated. Linear regression analysis was performed to give a coefficient of determination (R2). Results. The intra-rater reliability for all 3 protocols was rated as “very good” (Mayo 0.96, Berger 0.85 and CTTT 0.85). The inter-rater reliability for the Mayo and the Berger method was rated as “very good” (0.87 and 0.83 respectively), the CTTT was rated as “good” (0.79). The Mayo method had a lower mean difference in intra-rater measurements than the Berger method (1.42° vs 2.60° p= <0.01). Comparing the CTTT to the Mayo method produced an R2 value of 0.73 indicating strong correlation. As a screening tool, 92% of patients with CTTT ≤ 6mm had < 9° of tibial component internal rotation (IR), and 93% of patients with a CTTT ≥ 10mm had ≥ 9° IR. The Mayo method takes 3 minutes, 29 seconds; Berger method: 2 minutes, 5 seconds; CTTT method: 39 seconds to perform. Conclusion. 3D CT is the gold standard for formally determining tibial component rotational alignment. The CTTT has the strongest correlation to the Mayo method, and is the least time consuming. The CTTT method can be used as a reliable, simple and rapid screening tool in daily clinical practice to assess tibial component rotational alignment following TKA, prior to formal measurement. For any figures or tables, please contact authors directly


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_8 | Pages 28 - 28
1 Apr 2017
Rastetter B Wright S Gheduzzi S Miles A Clift S
Full Access

Background. Finite element (FE) models are frequently used in biomechanics to predict the behaviour of new implant designs. To increase the stability after severe bone loss tibial components with long stems are used in revision total knee replacements (TKR). A clinically reported complication after revision surgery is the occurrence of pain in the stem-end region. The aim of this analysis was the development of a validated FE-model of a fully cemented implant and to evaluate the effect of different tibial stem orientations. Methods. A scanned 4th generation synthetic left tibia (Sawbones) was used to develop the FE-model with a virtually implanted fully cemented tibial component. The 500 N load was applied with medial:lateral compartment distributions of 60:40 and 80:20. Different stem positons were simulated by modifying the resection surface angle posterior to the tibias shaft axis. The results were compared with an experimental study which used strain gauges on Sawbones tibias with an implanted tibial TKR component. The locations of the experimental strain gauges were modelled in the FE study. Results. Similar patterns and magnitudes of the predicted and experimentally measured strains were observed which validated the FE-model. An increase of strain at the most distal gauge locations were measured with the stem-end in contact to the posterior cortical bone. More uniform strain distributions were observed with the stem aligned to the intramedullary canal axis. The load distribution of 80:20 shifts the strains to tensile laterally and a large increase of compressive strain in the medial distal tibia. Conclusions. A contributory factor of the clinically reported stem-end pain is possibly the direct effect of contact of the tibial stem-end to the posterior region of the cortical bone. The increased load to the medial tibial compartment is more critical for the development of pain


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_7 | Pages 11 - 11
1 Apr 2014
Abram S Marsh A Nicol F Brydone A Mohammed A Spencer S
Full Access

When performing total knee replacement (TKR), surgeons must select a size of tibial component tray that most closely matches the anatomy of the proximal tibia. As implants are available in a limited range of sizes, it may be necessary to slightly under or oversize the component. There are concerns overhang could lead to pain from irritation of soft tissues, and underhang could lead to subsidence and failure. 154 TKRs at 1- or 5-year follow up were reviewed prospectively. Oxford Knee Score (OKS), WOMAC and SF-12 was recorded along with pain scores. Scaled radiographs were reviewed and grouped into perfect sizing (78 TKRs, 50.6%), underhang in isolation (48 TKRs, 31.1%), minor overhang 1–3 mm (10 TKRs, 6.49%) or major overhang >3 mm (18 TKRs, 11.7%). There was no significant difference in the SF-12 (p=0.356), post-operative OKS (p=0.401) or WOMAC (p=0.466) score. For the OKS, there was no difference for the scores collected at 1 year (p=0.176) or at 5 years (p=0.883). Pre-operative OKS was well matched between the groups (p=0.152). There was no significant difference in the improvement in OKS from pre-operative scores (p=0.662). There was no significant difference in either the OKS or WOMAC pain scores (p=0.237 and 0.542 respectively). There was no significant association of medial overhang with?medial knee pain (p=1.000) or lateral overhang with lateral knee pain (p=0.569) when compared to the group of patients with a well sized tibial component. Our results suggest that tibial component overhang or underhang has no detrimental affect on outcome or pain scores. Surgeons should continue to select the tibial component that most closely fits the rim of the proximal tibia while accepting slight overhang if necessary due to the potential longer-term complications of subsidence and premature failure with an undersized tibial tray


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_5 | Pages 29 - 29
1 Mar 2017
Mori S Inoue S Asada S Tsukamoto I Akagi M
Full Access

Background. Several studies have reported that tibial component in varus alignment can worsen the survivorship of medial unicompartmental knee arthroplasty (UKA). On the other hand, Varus/valgus inclination of the tibial component can affect the location of the contact point between femoral and tibial component especially in round on flat bearing surface design. Along with the tibial component inclination, changes in the contact point may also alter the tibial condylar bone stress, which would affect the longevity or complications after UKA. Method. We constructed a validated three-dimensional finite element model of the tibia with a medial component and assessed stress concentrations by changing the tibial component coronal inclinations (squale inclination, 3° and 6° varus, 3° and 6° valgus inclination). We evaluated the Von Mises stress on the medial tibial metaphyseal cortex and the proximal resected surface when a load of 900N was applied on the tibial component surface by two conditions in each inclination models; one is that the loading site is fixed at the mediolateral center of the tibial component (fixed model), and the other is that the loading site is variable depending on the tibial component inclination (variable model) (Fig.1). Result. In variable models, the loading site moved medially 22.8% of the tibial component width as the tibial component inclination changed from 6°varus to 6°valgus. The Von Mises stress concentrations were observed on the medial tibial metaphyseal cortices and on the anterior and posterior corner of the resected surface in all models (Fig.2). Stress concentration was also observed along the medial cortical rim of the resected surface in valgus tibial component inclination of the fixed model and varus inclination of the variable model (Fig.2). The stress on the medial tibial metaphyseal cortices did not markedly change in any inclination of fixed models, but increased in variable models as the tibial component inclination changed from varus to valgus (Fig.3A). The stress on the medial cortical rim of the resected surface increased with varus inclination in the fixed model and decreased with varus inclination in the variable model (Fig.3B). Changes in the Von Mises stress on the anterior and posterior corner of the resected surfaces did not differ between the fixed and variable model. Discussion. Varus inclination of the tibial component has been considered to increase the bone stress in previous studies. However, in the current study, bone stress on the medial metaphyseal cortex and the medial cortical rim of the resected surface conversely decreased in varus inclination when the change of the femorotibial contact point was taken into consideration. Recent opinion has advocated that restoring the constitutive patient's anatomy by compensating cartilage wear is critical in producing the excellent clinical outcome after UKA. Therefore, three to five degrees of anatomical varus inclination of the tibial component would reduce the tibial condylar bone stress and protective against complications such as unknown postoperative pain or tibial component migration. For figures/tables, please contact authors directly.


Orthopaedic Proceedings
Vol. 91-B, Issue SUPP_I | Pages 30 - 31
1 Mar 2009
Nicoll D Rowley D
Full Access

The aim of this study is to identify the incidence of mal-rotation of TKR components in a group of patients with unexplained knee pain identified from the University of Dundee joint replacement database and compare that group with a group of painless TKRs. 38 of 45 NexGen LPS Total Knee Replacements identified with unexplained pain at a minimum of 1 year following surgery underwent CT scanning to determine rotational alignment. All patients had a Knee Society Pain score of 20 points or less and a mean Visual Analogue Pain Score of greater than 4.0. This group was compared with a control group of 26 TKRs all of which had never reported pain from 1 year post surgery. In the painful group mean femoral component rotation was 2.2° of internal rotation (range 8.8°IR to 3.9°ER, sd 3.6, SEm 0.59) compared to 0.9°IR (range 6.9°IR to 6.8°ER, sd 3.39, SEm 0.67) in the painless group (p= 0.15). In the painful group 21.6% of femoral components were more than 6° internally rotated compared with 7.7% in the painless group however this was not statistically significant (p=0.18). No femoral components in either group were in excessive (over 8 degrees) ER. Tibial component rotation was much more variable than femoral component rotation in both groups particularly in the painful group. Mean tibial component rotation was 4.1°IR (range 37.9°IR to 31.1°ER, sd 14.6, SEm 2.4) in the painful group compared to 2.2°ER (range 8.5°IR to 18.2°ER, sd 6.95, SEm 1.36) in the painless group (p=0.024). 15 tibial components (39.5%) were greater than 10° internally rotated in the painful group whilst no tibial components were more than 10° internally rotated in the pain free group (p< 0.001). In the painful group 7 tibial components (18.4%) were more than 10° externally rotated whilst 4 (15.4%) were in more than 10° ER in the painless group (p=1.00). Overall 22 tibial components (57.9%) were in more than 10° of malrotation in the painful group compared with 4 (15.4%) in the pain free group (p=0.05). Mean rotational mismatch between femoral and tibial components was 1.9° tibial IR (range 39.7° tibial IR to 35.1° tibial ER, sd 16.1, SEm 2.7) in the painful group whilst in the painless group mean rotational mismatch was 3.1 degrees tibial ER (range 10.3° tibial IR to 22.1° tibial ER, sd 8.4, SEm 1.65). This difference was not significant (p=0.12). 16 TKRs (55.3%) had rotational mismatch of more than 10° in the painful group compared to 7 (26.9%) in the control group (p=0.02). We conclude that rotational malalignment is frequent in painful total knee replacements and may be a major cause of pain after TKR. In particular tibial internal rotation is the most frequent alignment error in the painful TKR and appears to play a major role in the aetiology of pain after TKR


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_2 | Pages 102 - 102
1 Jan 2016
Khuangsirikul S Chotanaphuti T
Full Access

Rotational malalignment in total knee arthroplasty (TKA) may lead to several complications. Transepicondylar axis has been accepted for a reference of femoral rotation. In contrast, standard reference of tibial rotation remains controversial. Currently, two techniques are widely used, the anatomical landmarks technique and the range-of-movement (ROM) technique. Fifty-one patients underwent posterior-stabilized TKA with center-post self-align ROM technique for tibial component placement. Laurin view radiograph and computer tomography (CT) were used to assess the prosthetic position. The rotational mismatch between tibial and femoral components was 2.00° ± 0.34° (range, 0.1°-5.8°). All TKA showed a tibiofemoral mismatch within 10° (range, 0.1° −5.8°). Intraoperative evaluation of patellar tracking by no-thumb test and the Laurin view showed normal range in 90%. We concluded that tibial component placement with center-post self-align technique in PS-TKA can produce good patellar tracking with acceptable range of tibiofemoral mismatch