A comprehensive understanding of the self-repair abilities of menisci and their overall function in the knee joint requires three-dimensional information. However, previous investigations of the meniscal blood supply have been limited to two-dimensional imaging methods, which fail to accurately capture tissue complexity. In this study, micro-CT was used to analyse the 3D microvascular structure of the meniscus, providing a detailed visualization and precise quantification of the vascular network. A contrast agent (μAngiofil®) was injected directly into the femoral artery of cadaver legs to provide the proper contrast enhancement. First, the entire knee joint was analysed with micro-CT, then to increase the applicable resolution the lateral and medial menisci were excised and investigated with a maximum resolution of up to 4 μm. The resulting micro-CT datasets were analysed both qualitatively and quantitatively. Key parameters of the vascular network, such as vascular volume fraction, vessel radius, vessel length density, and tortuosity, were separately determined for the lateral and medial meniscus, and their four circumferential zones defined by Cooper. In accordance with previous literature, the quantitative micro-CT data confirm a decrease in vascular volume fraction along the meniscal zones. The highest concentration of blood vessels was measured in the meniscocapsular region 0, which is characterized by vascular segments with a significantly larger average radius. Furthermore, the highest vessel length density observed in zone 0 suggests a more rapid delivery of oxygen and nutrients compared to other regions. Vascular tortuosity was detected in all circumferential regions, indicating the occurrence of vascular remodelling in all tissue areas. In conclusion, micro-CT is a non-invasive imaging technique that allows for the visualization of the internal structure of an object in three dimensions. These advanced 3D vascular analyses have the potential to establish new surgical approaches that rely on the healing potential of specific areas of the meniscus.
Distal femoral osteotomy is an established successful procedure which can delay the progression of arthritis and the need for knee arthroplasty. The surgery, however, is complex and lengthy and consequently it is generally the preserve of highly experienced specialists and thus not widely offered. Patient specific instrumentation is known to reduce procedural complexity, time, and surgeons’ anxiety levels1 in proximal tibial osteotomy procedures. This study evaluated a novel patient specific distal femoral osteotomy procedure (Orthoscape, Bath, UK) which aimed to use custom-made implants and instrumentation to provide a precision correction while also simplifying the procedure so that more surgeons would be comfortable offering the procedure. Three patients (n=3) with early-stage knee arthritis presented with valgus malalignment, the source of which was predominantly located within the distal femur, rather than intraarticular. Using conventional techniques and instrumentation, distal femoral knee osteotomy cases typically require 1.5–2 hours surgery time. The use of bi-planar osteotomy cuts have been shown to improve intraoperative stability as well as bone healing times2. This normally also increases surgical complexity; however, multiple cutting slots can be easily incorporated into patient specific instrumentation.Abstract
Background
Presenting problem
High tibial osteotomy (HTO) is a joint preserving alternative to knee replacement for medial tibiofemoral osteoarthritis in younger, more active patients. The procedure is technically challenging and limited also by ‘one size fits all’ plates which can result in patient discomfort necessitating plate removal. This clinical trial evaluated A novel custom-made HTO system – TOKA (3D Metal Printing LTD, Bath, UK) for accuracy of osteotomy correction and improvements in clinical outcome scores. The investigation was a single-arm single-centre prospective clinical trial (IRCCS Istituto Ortopedico Rizzoli; ClinicalTrials.gov NCT04574570), with recruitment of 25 patients (19M/6F; average age: 54.4 years; average BMI: 26.8), all of whom received the TOKA HTO 3D planning and surgery. All patients were predominantly diagnosed with isolated medial knee osteoarthritis and with a varus deformity under 20°. Patients were CT scanned pre- and post-operatively for 3D virtual planning and correctional assessment. All surgeries were performed by the lead clinical investigator – a consultant knee surgeon with a specialist interest in and clinical experience of HTO. On average, Knee Society Scores (KSS) improved significantly (p<0.001) by 27.6, 31.2 and 37.2 percentage points respectively by 3-, 6- and 12-months post-surgery respectively. Other measures assessed during the study (KOOS, EQ5D) produced similar increases. Our early experience using custom implants is extremely promising. We believe the reduced profile of the plate, as well as the reduced invasiveness and ease of surgery contributed to faster patient recovery, and improved outcome scores compared to conventional techniques. These clinical outcome results compare very favourably other case-series with published KOOS scores using different devices.
Meniscal allograft transplantation (MAT) for patients with symptomatic meniscal loss has demonstrated good clinical results and survivorship. Factors that affect both functional outcome and survivorship have been reported in the literature. These are typically single-centre case series with relatively small numbers and conflicting results. Our aim was to describe an international, two-centre case series, and identify factors that affect both functional outcome and survival. We report factors that affect outcome on 526 patients undergoing MAT across two sites (one in the UK and one in Italy). Outcomes of interest were the Knee injury and Osteoarthritis Outcome Score four (KOOS4) at two years and failure rates. We performed multiple regression analysis to examine for factors affecting KOOS, and Cox proportional hazards models for survivorship.Aims
Methods
High tibial osteotomy for knee realignment is effective at relieving symptoms of knee osteoarthritis but the operation is surgically challenging. A new personalised treatment with simpler surgery using pre-operatively planned measurements from computed tomography (CT) imaging and 3D-printed implants and instrumentation has been designed and is undergoing clinical trial. The aim of this study was to evaluate the early clinical results of a preliminary pilot study evaluating the safety of this new personalised treatment. The single-centre prospective clinical trial is ongoing (IRCCS Istituto Ortopedico Rizzoli; IRB-0013355; ClinicalTrials.gov NCT04574570), with recruitment completed and all patients having received the novel custom surgical treatment. To preserve the completeness of the trial reporting, only surgical aspects were evaluated in the present study. Specifically, the length of the implanted osteosynthesis screws was considered, being determined pre-operatively eliminating intraoperative measurements, and examined post-operatively (n=7) using CT image processing (ScanIP, Synopsys) and surface distance mapping. The surgical time, patient discharge date and ease of wound closure were recorded for all patients (n=25).Abstract
Objectives
Methods
Medial Knee Osteoarthritis (MKO) is associated with abnormal knee varism, this resulting in altered locomotion and abnormal loading at tibio-femoral condylar contacts. To prevent end-stage MKO, medial compartment decompression is selectively considered and, when required, executed via High Tibial Osteotomy (HTO). This is expected to restore normal knee alignment, load distribution and locomotion. In biomechanics, HTO efficacy may be investigated by a thorough analysis of the ground reaction forces (GRF), whose orientation with respect to patient-specific knee morphology should reflect knee misalignment. Although multi-instrumental assessments are feasible, a customized combination of medical imaging and gait analysis (GA), including GRF data, rarely is considered. The aim of this study was to report an original methodology merging Computed-Tomography (CT) with GA and GFR data in order to depict a realistic patient-specific representation of the knee loading status during motion before and after HTO. 25 MKO-affected patients were selected for HTO. All patients received pre-operative clinical scoring, and radiological/instrumental assessments; so far, these were also executed post-operatively at 6-month follow-up on 7 of these patients. State-of-the-art GA was performed during walking and more demanding motor tasks, like squatting, stair-climbing/descending, and chair-rising/sitting. An 8-camera motion capture system, combined with wireless electromyography, and force platforms for GRF tracking, was used together with an own established protocol. This marker-set was enlarged with 4 additional skin-based non-collinear markers, attached around the tibial-plateau rim. While still wearing these markers, all analyzed patients received full lower-limb X-ray in standing posture a CT scan of the knee in weight-bearing Subsequently, relevant DICOMs were segmented to reconstruct the morphological models of the proximal tibia and the additional reference markers, for a robust anatomical reference frame to be defined on the tibia. These marker trajectories during motion were then registered to the corresponding from CT-based 3D reconstruction. Relevant registration matrices then were used to report GRF data on the reconstructed tibial model. Intersection paths of GRF vectors with respect to the tibial-plateau plane were calculated, together with their centroids.Introduction and Objective
Materials and Methods
The medial opening-wedge high tibial osteotomy (OW-HTO) is an accepted option to treat the isolated medial compartment osteoarthritis (OA) in varus knee. Despite satisfactory outcomes were described in literature, consistent complication rate has been reported and the provided accuracy of coronal alignment correction using conventional HTO techniques falls short. Patient specific instrumentations has been introduced with the aim to reduce complications and to improve the intra-operative accuracy according to the pre-operative plan, which is responsible for the clinical result of the surgery. In this talk, an overview of the clinical results of HTO patient specific instrumentation available in literature will be performed. Moreover, preliminary intra-operative and clinical results of a new customised 3-D printed cutting guide and fixation plate for OW-HTO will be presented.
Physiological kinematics is very difficult to restore after total knee arthroplasty (TKA). A new model of medial stabilized (MS) TKA prosthesis has a high spherical congruence of the internal compartment, which guarantees anteroposterior (AP) stability associated with a flat surface of the insert in the lateral compartment, that allows a greater AP translation of the external condyle during knee flexion. The aim of our study is to evaluate, by dynamic radiostereometric analysis (RSA), the knee A cohort of 18 patients (72.1 ± 7.4 years old) was evaluated by dynamic RSA 9 months after TKA. The kinematic evaluation was carried out using the dynamic RSA tool (BI-STAND DRX 2), developed at our Institute, during the execution of sit to stand and lunge movements. The kinematic data were processed using the Grood and Suntay decomposition and the Low Point method. The patients performed two motor tasks: a sit-to-stand and a lunge. Data were related to the flexion angle versus internal-external, varus-valgus rotations and antero-posterior translations of the femur with respect to the tibia. During the sit to stand, the kinematic analysis showed the presence of a medial pivot, with a significantly greater (p=0.0216) anterior translation of the lateral condyle (3.9 ± 0.8 mm) than the medial one (1.6 ± 0.8 mm) associated with a femoral internal rotation (4.5 ± 0.9 deg). During the lunge, in the flexion phase, the lateral condyle showed a larger posterior translation than the medial one (6.2 ± 0.8 mm vs 5.3 ± 0.8 mm) associated with a femoral external rotation (3.1 ± 0.9 deg). In the extension phase, there is a larger anterior translation of the lateral condyle than the medial one (5.8 ± 0.8 mm vs 4.6 ± 0.8 mm) associated with femoral internal rotation (6.2 ± 0.9 deg). Analysing individual kinematics, we also found a negative correlation between clinical scores and VV laxity during sit to stand (R= −0.61) and that the higher femoral extra-rotation, the poorer clinical scores (R= 0.65). The finding of outliers in the VV and IE rotations analysis highlights the importance of a correct soft tissue balancing in order to allow the prosthetic design to manifest its innovative features.
Our aim was to perform a meta-analysis of the outcomes of revision
anterior cruciate ligament (ACL) reconstruction, comparing the use
of different types of graft. A search was performed of Medline and Pubmed using the terms
“Anterior Cruciate Ligament” and “ACL” combined with “revision”,
“re-operation” and “failure”. Only studies that reported the outcome
at a minimum follow-up of two years were included. Two authors reviewed
the papers, and outcomes were subdivided into autograft and allograft. Autograft
was subdivided into hamstring (HS) and bone-patellar tendon-bone
(BPTB). Subjective and objective outcome measures were analysed
and odds ratios with confidence intervals were calculated.Aims
Materials and Methods
The Pivot-shift phenomenon (PS) is known to be one of the essential signs of functional insufficiency of the anterior cruciate ligament (ACL). To evaluate the dynamic knee laxity is very important to accurately diagnose ACL injury, to assess surgical reconstructive techniques, and to evaluate treatment approaches. However, the pivot-shift test remains a subjective clinical examination difficult to quantify. The aim of the present study is to validate the use of an innovative non-invasive device based on the use of an inertial sensor to quantify PS test. The validation was based on comparison with data acquired by a surgical navigation system. The surgeon intraoperatively performed the PS tests on 15 patients just before fixing the graft required for the ACL reconstruction. A single accelerometer and a navigation system simultaneously acquired the joint kinematics. An additional optical tracker set to the accelerometer has allowed to quantify the movement of the sensor. The tibial anteroposterior acceleration obtained with the navigation system was compared with the acceleration acquired by the accelerometer. It is therefore estimated the presence of any artifacts due to the soft tissue as the test-retest repositioning error in the positioning of the sensor. It was also examined, the repeatability of the acceleration parameters necessary for the diagnosis of a possible ACL lesion and the waveform of the output signal obtained during the test. Finally it has been evaluated the correlation between the two acceleration measurements obtained by the two sensors. The RMS (root mean square) of the error of test-retest positioning has reported a good value of 5.5 ± 2.9 mm. While the amounts related to the presence of soft tissue artifacts was equal to 4.9 ± 2.6 mm. It was also given a good intra-tester repeatability (Cronbach's alpha = 0.86). The inter-patient similarity analysis showed a high correlation in the acceleration waveform of 0.88 ± 0.14. Finally the measurements obtained between the two systems showed a good correlation (rs = 0.72, p<0.05). This study showed good reliability of the proposed scheme and a good correlation with the results of the navigation system. The proposed device is therefore to be considered a valid method for evaluating dynamic joint laxity.
Anterior cruciate ligament (acl) reconstruction is one of the most commonly performed procedures in orthopedics for acl injury. While literature suggest short-term good-to-excellent functional results, a significant number of long-term studies report unexplained early oa development, regardless type of reconstruction. The present study reports the feasibility analysis and development of a clinical protocol, integrating different methodologies, able to determine which acl reconstruction technique could have the best chance to prevent oa. It gives also clinicians an effective tool to minimize the incidence of early oa. A prospective clinical trial was defined to evaluate clinical outcome, biochemical changes in cartilage, biomechanical parameters and possible development of oa. The most common reconstruction techniques were selected for this study, including hamstring single-bundle, single-bundle with extraarticular tenodesis and anatomical double-bundle. Power analysis was performed in terms of changes at cartilage level measurable by mri with t2 mapping. A sample size of 42 patients with isolated traumatic acl injury were therefore identified, considering a possible 10% to follow-up. Subjects presenting skeletal immaturity, degenerative tear of acl, other potential risk factors of oa and previous knee surgery were excluded. Included patients were randomized and underwent one of the 3 specified reconstruction techniques. The patients were evaluated pre-operatively, intra-operatively and post-operatively at 4 and 18 months of follow-up. Clinical evaluation were performed at each time using subjective scores (koos) and generic health status (sf-12). The activity level were documented (marx) as well as objective function (ikdc). Preliminary results allow to verify kinematic patterns during active tasks, including level walking, stair descending and squatting using dynamic roentgen sterephotogrammetric analysis (rsa) methodology before and after the injured ligament reconstruction. Intra-operative kinematics was also available by using a dedicated navigation system, thus to verify knee laxity at the time of surgery. Additionally, non-invasive assessment was possible both before the reconstruction and during the whole follow-up period by using inertial sensors. Integrating 3d models with kinematic data, estimation of contact areas of stress patterns on cartilage was also possible. The presented integrate protocol allowed to acquired different types of information concerning clinical assessment, biochemical changes in cartilage and biomechanical parameters to identify which acl reconstruction could present the most chondroprotective behavior. Preliminary data showed all the potential of the proposed workflow. The study is on-going and final results will be shortly provided.
Proper alignment (tibial alignment, femoral alignment, and overall anatomic alignment) of the prosthesis during total knee replacement is critical in maximizing implant survival[7] and to reduce polyethylene wear[1]. Poor overall anatomic alignment of a total knee replacement was associated with a 6.9 times greater risk of failure due to tibial collapse, that varus tibial alignment is associated with a 3.2 times greater risk[2] and valgus femoral alignment is associated with a 5.1 times greater risk of failure[7]. To reduce this variability intramedullary (IM) instruments have been widely used, with increased risk of the fat emboli rate to the lungs and brain during TKA[6] and possible increase of blood loss[4, 5]. Or, alternatively, navigation has been used to achieve proper alignment and to reduce morbidity[3]. Recently, for distal femoral resection, inertial sensors have been coupled to extramedullary (EM) instruments to improve TKA surgery in terms of femoral implant alignment, with respect to femoral mechanical axis, and reduced morbidity by avoidance of IM canal violation. The purpose if this study is to compare blood loss and alignment of distal femoral cut in three cohorts of patients: 1 Operated with inertial based cutting guide; 2 Operated with navigation instruments; 3 operated with conventional IM instruments. From September to November 2014 30 consecutive patients, eligible for TKA, were randomly divided into three cohorts with 10 patients each:x 1 “EM Perseus”, patient operated with EM inertial based instruments (Perseus, Orthokey Italia srl, Florence, Italy); 2 “EM Nav”, operated with standard navigated technique, where bone resections were planned and verified by mean of navigation system (BLUIGS, Orthokey Italia srl, Florence, Italy); 3 “IM Conv”, operated with standard IM instrumentation. All patients were operated by the same surgical technique, implanted TKA were mobile bearing PS models, Gemini (Waldemar Link, Hamburg, Germany) and Attune (Depuy, Warsaw, Indiana). Anteroposterior, lateral, and full-limb weightbearing views preoperatively and postoperatively at discharge were obtained, taking care of neutral limb rotational positioning in all patients enrolled in the study. Angles between femoral mechanical axis and implant orientation on frontal and lateral planes were measured with a CAD software (Rhinoceros 3, McNeel Europe, Rome, Italy) by two independent persons, average value was used for statistical analysis. Haemoglobin values were recorded at three time intervals: the day before surgery, at 24h follow-up and at patients discharge.Introduction
Material and methods
The purpose of this study was to examine whether three types of mobile-bearing PCL sacrificing TKA could restore the native knee translation and rotation. The primary hypothesis was that there are differences in knee kinematics and laxity between three different cruciate-substituting TKA designs: 1 with post-cam mechanism, 2 post-cam mechanism based on an inter-condylar ‘third condyle’ concept, 3 anterior stabilized with deep-dished highly congruent tibial insert; specifically, showing different femoral external rotation with flexion, different femoral translation with flexion and different laxity under stress test. The secondary hypothesis was that there is different clinical outcome between the three TKA designs at 2 years follow-up. We recruited 3 cohorts consisting of 30 patients each divided according 3 different TKA designs. All patients were operated with navigated procedure. During surgery preoperative and postoperative kinematics were recorded, in terms of femoral antero-posterior translation and tibial rotation during knee flexion, as also preoperative and postoperative at 2 years follow-up clinical scores have been acquired.Introduction
Methods
Providing proper rotational alignment of femoral component in total knee arthroplasty is mandatory to achieve correct kinematics, good ligament balance and proper patellar tracking. Recently functional references, like the function flexion axis (FFA), have been introduced to achieve this goal. Several studies reported the benefits of using the FFA but highlighted that further analyses are required to better verify the FFA applicability to the general clinical practice. Starting from the hypothesis that the FFA can thoroughly describe knee kinematics but that the joint kinematics itself can be different from flexion to extension movements, the purpose of this study was to analyse which factors could affect the FFA estimation by separately focusing on flexion and extension movements. Anatomical acquisitions and passive joint kinematics were acquired on 79 patients undergoing total knee arthroplasty using a commercial navigation system. Knee functional axis was estimated, from three flexion and extension movements separately acquired included in a range between 0° and 120°. For flexion and extension, in both pre- and post-implant conditions, internal-external (IE) rotations was analysed to track any changes in kinematic pattern, whereas differences in FFA estimation were identified by analysing the angle between the FFA itself and the transepicondylar axis (TEA) in axial and frontal plane.Introduction
Methods
Several methods, based on both functional and anatomical references, have been studied to reach the goal of a proper knee kinematics in total knee arthroplasty (TKA). However, at present, there is still a large debate about which is the most precise and accurate method to achieve the correct rotational implant positioning. One of the main methods already used in TKA to describe the tibiofemoral flexion-extension movement, based on a kinematic technique, thus not influenced by the typical variability related to the identification of anatomical references, is called “functional flexion axis” (FFA) method. The purpose of this study was to determine the repeatability in estimating knee functional flexion axis, thus evaluating the robustness of the method for navigated total knee arthroplasty. Passive kinematic and anatomical acquisitions were performed with a commercial navigation system on 87 patients undergoing TKA with primary osteoarthritis. Knee FFA was estimated, before and after implant positioning, from three flexion-extension movements between 0° and 120° (Figure 1). The angle between Functional Flexion Axis and an arbitrary clinical reference, the transepicondylar axis (TEA), was analysed in frontal and axial view (Figure 2). Repeatability Coefficient and Intraclass Correlation Coefficient (ICC) were estimated to analyse the reliability and the agreement in identifying the axis.Introduction
Methods
The use of a surgical navigation system has been demonstrated to allow to intraoperatively analyze knee kinematics during total knee arthroplasty (TKA), thus providing the surgeon with a quantitative and reproducible estimation of the knee functional behaviour. Recently severak authors used the computer assisted surgery (CAS) for kinematic evaluations during TKA, in particular to evaluate the achievement of a correct joint biomechanics after the prosthesis implantation. The major concern related to CAS is that the movements are usually passively performed, thence without a real active task performed by the subject. Starting from the hypothesis that the passive kinematics may properly describe the biomechanic behaviour of the knee, the main goal of this work was to intra-operatively compare the active kinematics of the limb, analysing a flexion movement actively performed by the patient, and the passive kinematics, manually performed by the surgeon. The anatomical and kinematic acquisitions were performed on 31 patients TKA using a commercial navigation system (BLU-IGS, Orthokey, USA). All the surgeries were performed under local anesthesia, which specifically allowed to acquire the passive and active kinematics including three flexion movements. Both in pre- and post-implant conditions, internal-external (IE) rotations and anterior-posterior (AP) translations were estimated to track any changes in the kinematic pattern.Introduction
Methods
The purpose of this study is to report results from a prospective multicenter study of a bioresorbable type I collagen scaffold used to replace tissue loss following irreparable lateral meniscus injuries. 49 non-consecutive patients (33M/16F; mean age 30.5 yrs, range 14.7–54.7 yrs) with irreparable lateral meniscus tears or loss requiring surgical treatment were prospectively enrolled at one of 7 EU centers. 11 patients (22%) had acute injuries of the lateral meniscus, while 38 (78%) had prior surgeries to the involved meniscus. Implantation of the LCMI (now Lateral Menaflex) was performed arthroscopically using an all-inside suturing technique (FASTFIX) combined with inside-out sutures in the more anterior meniscus aspect. Forty-three patients were evaluated with a 2 to 4-year follow-up (FU); mean FU duration was 45 months (range, 33–53 m). Patients were evaluated clinically and by self-assessment using Tegner activity and Lysholm function scores, as well as the Visual Analog Scales (VAS) for pain, and a satisfaction questionnaire. Evaluations were performed pre-operatively, 6 months, 1 year, 2 and 4 years after surgery. X-ray and/or MR-images were taken pre-operatively, and at 1 year and 2 years after surgery.INTRODUCTION
METHODS
The reported outcomes of unicompartmental knee replacement (UKR) for spontaneous osteonecrosis of the knee (SPONK) often derive from small series with an average followup of 5 years, enabling to generate meaningful conclusions. Therefore, we determined the long-term functional results and the 10-years survivorship of the implant in all patients with advanced SPONK of the medial tibio-femoral compartment treated with a unicompartmental knee arthroplasty at our institute. We retrospectively evaluated 84 consecutive patients with late stage SPONK. All patients received a pre-operative MRI to confirm the diagnosis, to exclude any metaphyseal involvement and to assess the absence of significative degenerative changes in the lateral and PF compartment. Mean age at surgery was 66 years and mean body mass index (BMI) was 28.9. In all cases, SPONK involved the medial compartment; in 77 cases the medial femoral condyle (MFC) was involved, while in 7 cases the pathology site was the medial tibial plateau (MTP). Radiological evaluation was conducted by 3 different radiologists and clinical evaluation according to KSS and WOMAC score was performed by 3 fellows from outside institutions, with no previous clinical contact with the patients, at a mean followup of 98 months.Background
Methods
This study aimed to intra-operatively quantify the improvements in knee stability given both by anatomic double-bundle (ADB) and single-bundle with additional lateral plasty (SBLP) ACL reconstruction using a navigation system. We prospectively included 35 consecutive patients, with an isolated anterior cruciate ligament injury, that underwent both ADB and SBLP ACL reconstruction (15 ADB, 20 SBLP). The testing protocol included anterior/posterior displacement at 30° and 90° of flexion (AP30–AP90), internal/external rotation at 30° and 90° of flexion (IE 30–IE90) and varus/valgus test at 0° and 30° of flexion (VV0–VV30); pivot-shift (PS) test was used to determine dynamic laxity. The tests were manually performed before and after the ACL reconstruction and the data were acquired by means a surgical navigation system (BLU-IGS, Orthokey, USA). Comparisons of pre- and post-reconstruction laxities were made using paired Student t-test (P=0.05) within the same group; comparison between ADB and SBLP groups was indeed performed using independent Student t-test (P=0.05), analysing both starting pre-operative condition and post-operative one.INTRODUCTION
MATERIALS AND METHODS
Several in vitro and in vivo studies have found correspondence between transepicondylar axis (TEA) and functional flexion axis (FFA) in healthy subjects. In addition some studies suggest that the use of FFA for rotational alignment of femoral implant may be more accurate than TEA. Ostheoarthritis (OA) may modify limb alignment and therefore flexion axis, introducing a bias at different flexion ranges during kinematic acquisition. In this study we want to understand whether OA affects somehow the FFA evaluation compared to TEA and whether the FFA could be considered a usable reference for implant positioning for osteoarthritic knees We included a group of 111 patients undergoing TKA. With a navigation system, we recorded intraoperative kinematic data in three different ranges of motion (0°-120°; 35°-80°; 35°-120°). We compared the difference in orientation of FFA (computed with the mean helical axis method) in the three ranges as also the difference with the TEA on frontal and axial planes. The correlation of preoperative limb deformity with FFA and TEA was also performed.Introduction
Methods
Patellar stability is an important component for a correct kinematic behaviour of the knee that depends on several factors such as joint geometry, muscles strength and soft tissues actions. Patellofemoral (PF) maltracking can results in many joint disorders which can cause pain and mobility alterations. The medial patellofemoral ligament (MPFL) is an important stabilizing structure for the patellofemoral joint. The aim of this study was to analyze patellofemoral kinematics with particular attention to the contribution of MPFL on patella stability. Using a navigation system PF kinematics during passive flexion/extension movements with quadriceps loaded at 60N, was recorded on 6 cadavers in three different anatomical conditions: intact knee, MPFL cut and MPFL reconstructed with graft. Test on patella was conducted without lateral force and with applied lateral force (25N). Tilt and lateral shift was evaluated in both cases at 0°. 30°, 60°and 90° of flexion.Introduction
Methods
We hypothesized that patients receiving a medial collagen meniscus implant (MCMI) would show better clinical, radiograpich and Magnetic Resonanace Imaging (MRI) outcomes than patients treated with partial medial meniscectomy (PMM) at minimum 10 year FU. Thirty-three non-randomized patients (males, mean age 40 years) were enrolled in the study to receive a MCMI (17 patients) or as control treated with a PMM (16 patients). All of them were clinically evaluated at time zero, 5 and minimum 10 years after surgery (mean FU 133 months, range 120–145) by Lysholm, VAS for pain, objective IKDC knee form and Tegner activity level. SF-36 score was performed pre-operatively and at final FU. Bilateral weight-bearing XRays were executed at time zero and at final FU. Minimum 10 years FU MRI images were compared with collected pre-operative MRI images by means of Yulish score. Genovese score was also used to evalute MCMI MRI survivorship.Purpouse
Material and Methods
Osteochondral defects are still a challenge for the orthopaedic surgeon, since most of the current surgical techniques lead to fibrocartilage formation and poor subchondral regeneration, often associated to joint stiffness and/or pain. Thinking of the ideal osteochondral graft from both the surgical an commercial point of view, it should be an off-the-shelf product; this is the research direction and the explanation for the new biomaterials recently proposed to repair osteochondral defect inducing an “in situ” cartilage regeneration starting from the time of the implantation into the defect site. For the clinical pilot study we performed, a newly developed nanostructured biomimetic scaffold was used to treat chondral and osteochondral lesions of the knee; its safety and manageability, as much as the surgical procedure reproducibility and the clinical outcome, were evaluated in order to test its intrinsic potential without any cells colture aid. A new osteochondral scaffold was obtained by enucleating equine collagen type 1 fibrils with hydroxyapatite nanoparticles in 3 different layers with 3 different gradient ratios at physiological conditions. 30 patients (9F, 21M, mean age 29,3yy) affected by either chondral or osteochondral lesions of the knee (8 medial femoral condyles, 5 lateral femoral condyles, 12 patellae, 8 femoral throcleas) underwent the scaffold implantation from January to July 2007. The sizes of the lesions were in between 2 and 6 squared cm. All patients and their clinical outcome were analyzed prospectively at 6, 12, 24 and 36 months using the Cartilage standard Evaluation Form as proposed by ICRS and an high resolution MRI.INTRODUCTION
MATERIALS AND METHODS
The menisci play a fundamental biomechanical role in the knee and also help in the maintaining of the articular homeostasis; thus, either a lesion or the complete absence of the menisci can invalidate the physiological function of the knee causing important damages, even at long term. Unfortunately, meniscal tears are often found during the ordinary orthopaedic practice while the regenerative potential of this kind of tissue is very low and limited to its peripheral-vascularized part; this is why the majority of these common arthroscopic findings are not reparable and often the surgeon is almost forced to perform a partial, subtotal or even total meniscectomy, regardless of the well-known consequences of this kind of surgery. Recently a porous, biodegradable scaffold made of an aliphatic polyurethane (Actifit(tm),Orteq Ltd) has been developed for the arthroscopic treatment of partial and irreparable meniscal tears; thanks to its particular structure, this scaffold facilitates the regeneration of the removed meniscal part, preventing the potential cartilage damage due to its complete or partial lack. We performed a prospective clinical study on 17 patients affected by a massive loss of meniscal substance either medial or lateral associated with intraarticular or global knee pain and/or swelling. We analyzed the patient both clinically and by using the International Knee Document Committee's (IKDC) Subjective and Objective Knee Evaluation Form. We also assessed the sport activity resumption by comparing the Tegner score at the time of the very first visit with the presurgery and prelesional ones. Finally, we also organized a control MRI at 6 and 12 months after surgery.INTRODUCTION
MATERIALS AND METHODS
We have shown in a previous study that patients with combined lesions of the anterior cruciate (ACL) and medial collateral ligaments (MCL) had similar anteroposterior (AP) but greater valgus laxity at 30° after reconstruction of the ACL when compared with patients who had undergone reconstruction of an isolated ACL injury. The present study investigated the same cohort of patients after a minimum of three years to evaluate whether the residual valgus laxity led to a poorer clinical outcome. Each patient had undergone an arthroscopic double-bundle ACL reconstruction using a semitendinosus-gracilis graft. In the combined ACL/MCL injury group, the grade II medial collateral ligament injury was not treated. At follow-up, AP laxity was measured using a KT-2000 arthrometer, while valgus laxity was evaluated with Telos valgus stress radiographs and compared with the uninjured knee. We evaluated clinical outcome scores, muscle girth and time to return to activities for the two groups. Valgus stress radiographs showed statistically significant greater mean medial joint opening in the reconstructed compared with the uninjured knees (1.7 mm (
Traumatic anterior shoulder dislocation and sub-luxation are common injuries. But few studies have compared arthroscopic and open stabilization of the shoulder at long-term follow up. The purpose of our study is to show whether an arthroscopic approach to repair Bankart lesion can obtain the same results at long follow up as an open procedure. We analyzed 110 non-randomized consecutive shoulders in 110 patients who underwent a surgical repair of recurrent anterior shoulder instability between 1990 and 1999. Eighty-two patients were available at long term follow up (74,5% retrieval rate). In particular, 49 patients (59.8%) (group A) were treated with arthroscopic transglenoid suture (modified Caspari) between 1990 and 1995 (mean 15,7 year FU), whereas, 33 patients (40.2%) (group B) were treated with open repair between 1995 and 1999 (mean 12,7 year FU). We evaluated the patients in terms of failure rates, Rowe and UCLA scores. The failure cases in the forty-nine patients treated with arthroscopic suture were 13, six dislocations and seven subluxations. The group A had also a Rowe score: function 24.2+8.2, stability 42.4+13.9, range of movement 18.6+3.8, total score 85.0+22.46. The UCLA score was: pain 8.8+1.7, function 8.6+2.1, muscle power 9.2+1.6, total score 26.4+4.8. Of the thirty-three patients treated with open repair, three had at least one post-op dislocations and four felt sometimes subluxations. The Rowe score in group B was: function 23.6+9.7, stability 41.2+14.9, range of movement 18.3+3.9, total score 83.2+24.4. Moreover the UCLA score was: pain 8.8+1.9, function 8.8+1.9, muscle power 9.2+1.2, total score 26.9+4.2. We showed that both techniques were fairly good in treatment of shoulder instability. In our series no significant difference was observed in redislocation rate and in Rowe and UCLA scores between the two groups. The recurrence rate (subluxations and dislocations) was high in both groups: the arthroscopic group had 26.5% and the open one had 21.2%. Our recurrence rate following open repair was higher than in many studies, while the rate after arthroscopic transglenoid procedure was almost equivalent. We hypothesize that one of the reasons for these higher recurrence rates may be the long term follow up. Another cause could be our decision to include subluxation as a failure value, even if there is no agreement about. In fact we believe it to be an important disability factor in sport as in life activities. After surgery, most of the patients returned to their preinjuried activities. But at long term follow up almost all patients have stopped high level sport activity. Moreover, at this long term follow up, some patients told us a feeling of muscle weakness in the last years. In conclusion patients had good impressions about their shoulders thanks to surgery, but also because of lower functional demand.
We performed a clinical, instrumental and radiographic study on a highly homogeneous series of 100 consecutive patients with unilateral ACL lesion at 7 years of minimum follow up, alternatively assigned to a single bundle reconstruction using patellar tendon (PT) or to a double bundle reconstruction using hamstrings (DB). Mean Tegner score was 4,8 for PT and 6,5 for DB (p=0,0005). Time for sport resumption was 6,6 months for PT and 3,8 months for DB (p=0,0052). There were no significative differences between the two groups regarding range of motion and functional subjective self-evaluation. Mean anterior displacement at instrumental evaluation performed with KT2000 showed no significative differences between the two groups. Objective clinical evaluation with IKDC was superior for DB group (A=86,5%; B=13,5%) respect to PT group (A=18,7%; B=75%; C=6,3%) (p<
0,0001). We found no differences regarding anterior knee pain between and Ahlback radiographic score the two groups and we have observed no recurrence of instability after surgical treatment. Double bundle ACL reconstruction with hamstrings has showed higher results respect to single bundle ACL reconstruction with patellar tendon in terms of Tegner score, IKDC, time for sport resumption.
We performed a retrospective clinical and radiographic evaluation of 100 cases operated in our institute between February 1996 and March 2003 with a mean follow-up of 60 months to assess the efficiency of UKR performed with a new minimally invasive technique. The aim of this study is to correlate the clinical outcome of the patients with the pre- and post-op alignment, and with implant positioning on coronal and sagittal plane. 100 patients (23 ♂, 64 ♀) underwent cemented UKR (De Puy Preservation Uni with all poly tibial component), both for arthritis and osteonecrosis. At the pre-op clinical and radiographic evaluation, 82 patients presented a varus deformity, 5 patients a valgus deformity. The Hospital for Special Surgery Score (HSS) was used to determine the subjective and objective clinical status of the patients before and after the intervention. Pre-op antero-posterior (AP) x-rays of the knee were executed to establish the femoro-tibial angle (FTA) and the angle between the affected tibial plateau and the tibial anatomical axis (PTA), while latero-lateral (LL) x-rays were performed to determine the posterior tibial slope (PS). To analyze ligamentous balancing, x-rays were performed both in supine and in plain weight bearing stance. Post-op, we performed supine AP e LL X-rays and at a mean follow-up of sixty months (12–84 months) we performed AP and LL plain weight bearing x-rays. We considered a knee with FTA >
175° as varus knee, 170°<
FTA<
175° as normal knee and an FTA <
170° as valgus knee. Moreover, we assumed a TPA >
90° for valgus knee and a TPA<
90° for varus knee. According with HSS scoring system, at a mean follow-up of 60 months, 63 (76%) cases were excellent (100-85 points), 15 (18%) cases were good (84-70 points), 5 (6%) bad results (<
60 points). Our results demonstrate that patients with a pre-operative varus alignment of 7 degrees are slightly more likely to be selected for UKR. In our series, patients with an excellent clinical result presented pre-operatively a mean varus deformity of 7,9°. According to literature, we demonstrated that a small amount of undercorrection with a residual varus deformity of 3–5° is the goal to be reached in order to avoid both rapid degeneration of the non-replaced compartment as well as the premature loosening of the replaced compartment. We performed a mean axial correction of 5,1° leaving a mean axial varus deformity of 2,8° in the excellent group. In our series the group with excellent results also showed a post-operative PTS of 7,1°, while mean pre-operative PTS was 6,6°. Moreover, the further our radiographic findings were from the optimal position suggested, the worst were the results : a decrease was evident comparing excellent group with good group and this was even more marked comparing excellent group with bad results group.
Arthroscopic selective resurfacing of the knee may be considered a treatment option for selected patients with focal articular damage. From more than 2 years in IX Division of Rizzoli Orthopaedics Institute(Bologna- Italy) we use, in selected cases with only one articular compartment damaged, an innovative resurfacing prosthesis. We mad a new design of focal resurfacing (MAIOR) that is possible to implant with arthroscopic technique and that realize both mini-invasive and mini-traumatic surgery. The fixation method of the MAIOR allows higher osteointegration by biomaterials and hydrossiapatite of new generation that permit a press-fit fixation of the implant. The new philosophy of this implant consist of early focal treatment with low compromise of bone. Many surgeons, in case of focal articular damage, prefer to attend to made an unique definitive surgical operation when the degenerative changes are more severe. This new implant permit to substitute, also in arthroscopic technique, only the articular damage and to avoid to attend a more important and diffuse articualr damage. It is an uncemented, focal resurfacing prosthesis that requires minimal bone sacrifice and utilizes a minimal invasive surgical (MIS) approach with or without arthroscopic assistance. In a prospective and consecutive study, 78 patients were followed up at least for 12 months. Subjective pain and joint function were assessed using Visual analogue scale (VAS) and Knee society scores respectively. The preliminary results are interesting and encouraging with subjective evaluation equal to 85% of normal knee. Significant reduction of pain and improvement in joint function was observed. Although, long term study will determine the real performance of the prosthesis, trend seems to be positive.
Information on knee kinematics during surgery is currently lacking. The aim of this study is to describe intra-operative kinematics evaluations during uni-compartmental knee arthroplasty (UKA) and total knee arthroplasty (TKA) by mean of a navigation system. Anatomical and kinematic data were acquired by Kin-Nav navigation system and analysed by a dedicated elaboration software developed at our laboratory. The study was conducted on 20 patients: 10 patients undergoing mini-invasive UKA and 10 patients undergoing posterior-substituting-rotating-platform TKA. In both group of patients the surgeon performed passive knee flexion immediately before and immediately after the prosthetic implant. Pattern and amount of internal/external tibial rotation in function of flexion were computed and significant changes between before and after implant were evaluated adopting Student’s t-test (significant level p=0.05). UKA implant did not significantly change the pattern of internal/external tibial rotation, nor the total magnitude of tibial rotation (15.75°±7.27°) during range of flexion (10°–110°), compared to pre-operative values (17.87°±7.34°, p=0.25). Magnitude of tibial rotation in TKA group before surgery (8.00°±3.67°) was significantly less compared to UKA patients and did not changed significantly after implant (5.96°±4.88°, p=0.09). Pattern of rotation before and after TKA implant were different between each other and between pattern in UKA patients both before and after implant. Intra-operative evaluations on tibial rotation during knee flexion confirmed some assumptions on knee implants from post-operative methods and suggest a more extensive use of surgical navigation systems for kinematic studies.
Total knee arthroplasty (TKA) is actually a satisfactory technique to reduce pain and enhance mobility in osteoartritic pathologies (OA) of the knee. However, life of the implant is strictly dependent on restoration of correct knee kinematics, as alteration of motion pattern could led to abnormal wear in prosthetic components and also damage soft tissues. The aim of our study was to evaluate new kinematic tests to be performed during surgery in order to improve the standard intra-operative evaluation of the outcome on the individual case. We used Kin-Nav navigation system to acquire anatomic and kinematic data, which were analysed by a dedicated elaboration software developed at our laboratory. Ten patients undergoing rotating platform cruciate substituting TKA were considered for this study. Immediately before the implant and immediately after component positioning, the surgeon performed 3 complete knee flexion imposing internal tibial rotation (IPROM) and 3 complete knee flexion imposing external tibial rotation (EPROM). Tibial rotation during IPROM and EPROM tests was plotted in function of flexion (in the range 10°–110°). Repeatability of IPROM and EPROM was tested by calculating ICC (Intra-class Correlation Coefficient) between 3 repeated curves. Distance between IPROM curve and EPROM curve was computed at various degree of flexion. Maximum distance obtained during all range of flexion before and after the implant were compared by Student’s t-test (significant level p=0.05). ICC for repeated motions were 0.99 for IPROM and 0.98 for EPROM. Maximum distance between tibial rotation in IPROM and EPROM was 27.82±6.98 before implant and significantly increased (p=0.001) to 40.09±6.92 after TKA. In one case we observed that the value remained similar before and after implant (from 33.11 to 33.98) while in one case we observed very large increase of rotation (from 30.56 to 50.01). The proposed kinematic tests were able to quantify the increase of tibial rotation after TKA implant. Future development of the study are encouraging and will include a larger sample and reflections on individual findings.
Samples prepared with Karnowsky fixing and urani-lacetate solution. Fibril diameter and transversal area measured by LEICA QUIN in 5 cuts randomly selected for each sample.
Investigation based on: Sport activity recover; IKDC; KT2000; isokinetical tests; muscular throphysm recover; Tegner and Lyshom score; Activity Rating Scale (ARS); Psychovitality Questionnaire; radio graphical evaluation in AP, LL and Rosemberg.
DB technique allows a faster sport activity and muscular throphysm recover and better results in the isoci-netical tests.
The kinematic effect of tunnel orientation and position, during ACL reconstruction, has been only recently related to the control of rotational instability. This paper presents a detailed computer-assisted in vitro evaluation of two different femoral tunnel orientations with the same tunnel position, at 10.30 ‘o clock, during the intervention of ACL reconstruction with double bundle technique. Results highlighted better kinematic performances of the horizontal tunnel, with respect to the vertical one, in controlling antero-posterior (AP) laxities at 30°, and internal-external (IE) laxities. Elongations of anterior and posterior bundles of reconstructed ACL, for both reconstruction, decreased during PROM respectively by 20% and 40%. Total length of the graft varied during PROM, mainly due to graft elongation during tests, graft length on horizontal tunnel varied from 237 to 213mm while graft length on vertical tunnel varied from 257 to 233mm. Kinematic tests showed a better performance of horizontal tunnel in the control of IE rotations at 30° and 90° and of the Lachman test with respect to the vertical one. Stability was restored with both reconstructions.
A computer assisted technique for TKA Revision is presented. It is based on the use of a navigation system, RTKANav consisting of anl optical localizer, a dedicated software specifically done for TKA revision and some navigated tools developed for this application. The system doesn’t use any patient model derived from medical images, but on the system interface patient anatomy model is represented with dots and lines corresponding to acquired landmarks and data derived from them. These data describe the main anatomical features and provide the surgeon with the main references for the intervention; angles between the mechanical axes can be controlled and monitored at any time. Even if during acquisition phase some specific points can not be identified, since for each prosthetic component several criteria to set each degree of freedom are considered and compared, the system is always able suggest an intervention plan. The system provides the surgeon with tools to analyse and modify the proposed plan, and to reproduce it on the patient. Navigated technique validation is under development. Till now it was used on two patients by an expert surgeon. Computer guidance showed early promising results providing the surgeon with useful indications achieve a satisfactory prosthesis implant.
This study identifies parameters that allow to foresee the necessity of soft tissue release (STR) before surgery. Femoral and tibial morphotype were defined evaluating several radiological parameters. Intra-operative STR during surgery was correlated to radiographic parameters identified. 33 cases were analysed and divided in 2 groups, release (6) no release (27), statistical evaluation has been performed using Mann-Whitney test and contingency tables for most relevant parameters. Three parameters were measured on femur and four on tibia. The results confirmed the usability of angle between femoral anatomical axis and transepicondylar axis ATA (p<
0.001) and between femoral mechanical axis and tangent to distal condyles MCA (p<
0.001 ) as predictors, among tibial parameters angle between mechanical axis and tangent to tibial plateaux gives good results (p=0.028).The use of contingency tables highlighted that the combined use of ATA and MCA, gives better specificity than the use of a single angle.
Large bone defect repair has always presented a difficult treatment problem. Marrow-derived osteogenic progenitor cells combined with hydroxyapatite (HA) were used for segmental bone reconstruction. The validity of this model has been shown for the repair of bone defects of critical size in large animal models. We used this cell-based therapeutic approach to treat three patients with large bone defects. The patients were 41, 22 and 16 years old and had large tibial, ulnar and humeral diaphyseal gaps that ranged in size from 3.0 to 28.3 cm3. Marrow samples were harvested from the iliac crest and osteogenic progenitors isolated and expanded “ex vivo”. The expanded cells were then combined with a highly macroporous bioceramic scaffold whose size and shape reflected each individual bony defect. The cell/bioceramic composites were implanted at the lesion sites. External fixation was used to stabilise the grafts. At present all patients have been followed up for 4–5 years. Already after the first month after surgery an initial integration at the bone/implant interface was evident. Bone formation in the implants, assessed by X-ray, progressed steadily in the follow-up period. Two patients achieved full functional recovery at 6 months after surgery, one patient at 12 months after surgery. The present report shows that large segmental bone reconstruction can be achieved in humans using osteoprogenitor cells. This technique can be improved by a more biodegradable and more biomechanically resistant scaffold use.
Autologous chondrocyte transplantation has become a possible solution for the treatment of chondral knee lesions. Recently an autologous tissue engineered cartilage (Hyalograft C), using biodegradable scaffolds for cell proliferation, was successfully developed. In osteochondritis dissecans (OCD) the lesion also involves subchondral bone. For this reason we began to use a two-step technique: arthroscopic autologous bone grafting followed by autologouos condrocyte Hyalograft C transplantation after 4–6 months. We treated five patients affected by OCD. All the patients were clinically evaluated and analysed according to the International Repair Cartilage Society score at 12 and 24 months. The ICRS score showed highly satisfactory clinical results in all treated patients at 12 and 24 months; CT and MRI evaluation had demonstrated a good articular surface reconstruction with complete bone defect restoration at a short 12-month follow-up period. The autologous chondrocyte transplantation provides highly satisfactory clinical results. This second-generation autologous tissue-engineered cartilage transplantation avoids the use of periosteal flap, simplifies the surgical procedure and permits use of an arthroscopic approach. In association with autologous bone grafting, bone loss can also be restored in order to recreate a perfect articular surface. The preliminary clinical and histological results are encouraging but longer follow-up is required to better evaluate this technique.
Rotational defects of the lower limb are frequently encountered and often underestimated. In fact, many symptoms in the lower joint can be related to rotational alteration in the lower leg. These problems are often more visible in the knee joint because they reflect the rotational problems of proximal and distal femur and tibia, respectively. The extensor apparatus, due to the fact that it interacts with both bones, is the more affected joint. Many authors have demonstrated that femoral anteversion increases stress on the patello-femoral joint due to excessive lateralisation of the patella. In the same manner, distal femur internal rotation increases the stress due to altered tracking of the patella during ROM. Valgus knee places stress on the patello-femoral joint, increasing the Q angle and determining a retraction of the lateral structure that causes stress on the lateral patellar face and altered patellar scratch during ROM. External tibial rotation also has been documented to increase the Q angle and patellar tilt, causing excessive stress on the patello-femoral joint. Valgus pronation of the foot, increasing the valgus stress on the knee, can contribute to patello-femoral symptoms, increasing the muscle imbalance at this level. These documented alterations contribute together with other anatomical abnormalities, such as trochlear dysplasia or muscle hypoplasia, in creating the high variability of patello-femoral symptoms that are observed. Rotational deformity of the lower leg therefore represents a frequently encountered pathological condition that must be taken into account when treating patello-femoral symptoms.
A tissue engineering-based approach has become a possible solution for the treatment of chondral lesions. Actually, autologous chondrocytes seeded on biodegradable scaffolds for cell proliferation were successfully developed. However, these techniques promote cartilaginous but not bony regeneration. Therefore a new experimental approach involving mesenchymal stem cells (MSC) has been introduced. A 31-year-old man affected by massive osteonecrosis of the right femoral head was selected to begin this study. The MSC were isolated from the bone marrow harvested from the patient’s iliac crest. After a 3-week monolayer expansion, cells were seeded and cultured onto hyaluronan-based three-dimensional scaffolds and DBM spongy chips, used to regenerate the cartilaginous and the bony portion, respectively. After a 2-week cultivation, constructs were implanted inside the osteochondral defect using the transtrochanteric approach under arthroscopic control. The patient underwent clinical, X-ray and MRI control during the first 6 months after operation. Pluripotent MSC may be a promising strategy for osteochondral defect reconstruction due to their capacity to differentiate in vivo along chondrocytic and osteoblastic lineages. This ability, combined with two different kinds of three-dimensional scaffolds, permits simultaneous bone and cartilage tissue regeneration. The preliminary results are encouraging but a more precise judgement of the effectiveness of this method requires longer follow-up.
Valgus deformity of the knee in relation to femoral dysplasia and post-traumatic varus deformity in relation to supracondylar fracture often needs to be corrected with varus or valgus distal femoral osteotomy. This procedure must be very precise to avoid compartimental overstress. However, in valgus knee the deformity is very often not only bi-planar but also tri-planar. In fact, the rotational defect of the distal femur can play an important role in determining the clinical symptoms and in altering the pathway of patello-femoral joint. Therefore, correcting only the valgus deformity does not solve the clinical symptoms related to incorrect rotation of distal femur. The same problem is often encountered in distal femoral deformity in relation to supracondylar fracture. The bad alignment of the healed fracture is very often on the three planes and this fact has always to be taken into account during the pre-operative planning. The pre-operative planning is fundamental and CT of the knee joint with reference to hip and ankle must be performed to evaluate the degree of rotational deformity that must be corrected. During surgery after the correction of valgus or varus deformity is fundamental to re-check the femur rotation, because the osteotomy automatically changes also the rotation of the distal femur. However, this correction may be insufficient to correct the rotation that can maintain clinical symptoms in the patello-femoral joint. If this is the case, an additional correction in external rotation is usually necessary to achieve an overall correction of distal femoral deformity. In our opinion, the difficulties and accuracy necessary to correct this type of pathology are often underestimated.