header advert
Results 1 - 100 of 430
Results per page:
Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_5 | Pages 12 - 12
1 Apr 2018
Moharamzadeh D Piarulli G Molisani D Andreoletti G
Full Access

Cementless total knee replacement (TKR) is at the present date a controversial topic. Aim of the study was to compare the effect on tibial periprosthetic bone mineral density (BMD) between different implant materials and designs. During the two-year period between January 2005 and December 2006, we analysed data of 45 patients who underwent consecutively cementless TKR (49 implants) at our Institution for primary osteoarthritis. Data was divided in 2 groups: A) 26 implants with tantalium tibial component (Zimmer NexGen Trabecular Metal. TM. Monoblock); B) 23 implants with porous titanium tibial component (Lima MultiGen. TM. ). Data was comparable per sex, age, BMI, post-op alignment, post-op KSS > 75, absence of major post-op complications. Standard AP x-rays were taken 4 months post-op and 8 years post-op. In order to quantify the reduction of BDM, we determined using ImageJ (an open source software) the Mean Grey Value (MGV) of a specific area on the 4 months- and 8 yrs-postop AP x-rays. Group A and Group B had an average MGV variation of, respectively, 11.79% and 10.51%; there was no statistically significant difference between the two groups. Reduction of BMD in a TKR is known to be a biomechanical response to load and it is conditioned by the alignment of the components and their design. Our study shows that the different materials (porous titanium vs. tantalium), in relation to the different implant design, have a similar effect on the surrounding bone. The overall results show a valid osseointegration in both group of patients


Orthopaedic Proceedings
Vol. 91-B, Issue SUPP_III | Pages 450 - 451
1 Sep 2009
Penny JO Ovesen O Varmarken J Brixen K Overgaard S
Full Access

Resurfacing THA is claimed to transfer stress naturally to the femur neck and preserve proximal femoral bone mass postoperatively. DXA is an established method in estimating BMD around a standard THA, but due to the anteversion of the femur neck, rotation could affect the size of the neck-regions and thereby the BMD measurements around a RTHA. To our knowledge, this is the first study to analyze the effects of hip rotation on BMD in the femoral neck around a RTHA.

We scanned the femoral neck of 15 patients twice in each position of 15° inward, 0° and 15° outward rotation, and analyzed BMD in a single and a six-region model. CVs were calculated for BMD in the same position as well as between different positions.

For double measurements in the same position we found mean CVs of 3.1% (range 2.5% – 3.7%) and 4.6% (range 2.2% – 8.6%) in the one- and six-region models, respectively. When the 15° outward position was excluded, the CVs decreased to 2.8% and 4.0%. With rotation, the mean CVs rose to 5.4% (range 3.2%–7.2%) and 11.8% (range 2.7% – 36.3%). This effect was most pronounced in the 6-region model, predominantly in the lateral and distal parts of the femoral neck, where the change was significantly different from the fixated position. For the single-region model 15° rotation could be allowed without compromising the precision.

We conclude that rotation adversely affects the precision of BMD measurements around a RTHA, but in the single-region model smaller rotations can be allowed.

With the hip fixated the six-region model produces low CVs, acceptable for longitudinal studies. For maximal topographical detail we prefer the six-region model and recommend that future longitudinal DXA studies, including RTHA, be performed standardised, Preferably, with the hip in the neutral or internal rotation.


Orthopaedic Proceedings
Vol. 91-B, Issue SUPP_I | Pages 145 - 145
1 Mar 2009
Albanese C Lucidi M Rendine M Santori N Pavan L Passariello R Santori F
Full Access

Introduction: Bone resorption in the proximal femur is commonly seen after cementless total hip arthroplasty (THA). One of the main determinants of bone remodeling seems to be prosthesis design. With DXA, the amount of bone mass after THA can be precisely determined. We evaluated the BMD behavior of two different ultra-short implants with proximal load transfer, in order to study how a design can affect femoral bone remodeling. The rationale behind these designs is the experimental evidence that loading the medial and the lateral flare effectively preserves in time metaphyseal bone stock. Moreover, biomechanical tests have confirmed that this kind of stress distribution allows to remove the diaphyseal portion of the stem.

Methods: A total of 33 patients operated with a cementless femoral implant were included in this study. Two slightly different designs were tested: Type 1 (Stanmore Orthopaedics), featuring an extremely short distal stem (n=10), and Type 2 (DePuy International Ltd), where distal stem was virtually absent (n=23). All implants were customized based on pre-operative CT data. The main features of these implants were the ultra-short stem and the large lateral flare. The rationale was to preserve bone stock and gain a more physiologic load transfer to the proximal femur thus preventing stress-shielding. DXA examination was performed on all patients 3 years after THA. Due to the peculiar design, a specific protocol of analysis with five regions of interest (ROI) was developed: ROI1 (greater trochanter), ROI2 and ROI4 (respectively lateral and medial of the ultra-short stem), ROI3 (below the tip) and ROI5 (calcar). The same protocol was applied to the non-operated contralateral femur and percentage contralateral BMD was calculated with the following formula: (BMD of operated hip/BMD of contralateral hip)×100. A standard DXA of contralateral hip and lumbar spine was also performed to evaluate the skeletal bone mineralization.

Results: No differences were found in the anthropometric data and sex between the two groups. Age was found lower (p=0.001) in Type 2. BMD of lumbar spine and contralateral femur from standard DXA were not different in the two groups. BMD was higher in Type 2 in ROI4 and ROI5 (p< 0.001). The calculated percentage contralateral BMD was higher in Type 2 in ROI2 (p=0.009), ROI4 (p< 0.001) and ROI5 (p=0.01).

Conclusions: This study confirms that progressive shortening of femoral stem produces a more proximal loading, which effectively preserves in time metaphyseal bone stock and increases periprosthetic BMD in the medial ROIs. The increased BMD in periprosthetic lateral and medial proximal regions in the operated hip respect to the contralateral femur seems to be due not only to the increased weight-bearing, but also to the specific ultra-short stem design.


Orthopaedic Proceedings
Vol. 86-B, Issue SUPP_III | Pages 249 - 249
1 Mar 2004
Remes T Väisänen S Mahonen A Huuskonen J Kröger H Jurvelin J Rauramaa R
Full Access

Aims: The purpose of this study was to investigate interactions of vitamin D receptor gene (VDR) polymorphisms and regular physical exercise on BMD in a four-year randomized, controlled intervention trial in Finnish middle-aged men. Methods: The TaqI, FokI, and ApaI RFLP-markers of the VDR gene were evaluated. BMDs of the lumbar spine (L2–L4), femoral neck, and total proximal femur were measured with a dual-energy X-ray absorptiometry (DXA). Results: In the entire study group, the subjects with the VDR gene TaqI Tt or tt genotype had a greater body height and higher femoral neck BMD values than the TT subjects (p=0.001, p=0.003, respectively). After adjustment the femoral neck BMD for body height, the association remained (p=0.021). There was no difference in BMD values between the reference and exercise groups during intervention. Conclusions: We suggest that the VDR gene TaqI polymorphism may be affecting bone mass through an influence on body growth. The present findings also suggest that the VDR polymorphisms do not modify the effect of regular aerobic exercise on BMD.


Bone & Joint Research
Vol. 11, Issue 5 | Pages 304 - 316
17 May 2022
Kim MH Choi LY Chung JY Kim E Yang WM

Aims. The association of auraptene (AUR), a 7-geranyloxycoumarin, on osteoporosis and its potential pathway was predicted by network pharmacology and confirmed in experimental osteoporotic mice. Methods. The network of AUR was constructed and a potential pathway predicted by Kyoto Encyclopedia of Genes and Genomes (KEGG) pathway and Gene Ontology (GO) terms enrichment. Female ovariectomized (OVX) Institute of Cancer Research mice were intraperitoneally injected with 0.01, 0.1, and 1 mM AUR for four weeks. The bone mineral density (BMD) level was measured by dual-energy X-ray absorptiometry. The bone microstructure was determined by histomorphological changes in the femora. In addition, biochemical analysis of the serum and assessment of the messenger RNA (mRNA) levels of osteoclastic markers were performed. Results. In total, 65.93% of the genes of the AUR network matched with osteoporosis-related genes. Osteoclast differentiation was predicted to be a potential pathway of AUR in osteoporosis. Based on the network pharmacology, the BMD and bone mineral content levels were significantly (p < 0.05) increased in the whole body, femur, tibia, and lumbar spine by AUR. AUR normalized the bone microstructure and the serum alkaline phosphatase (ALP), bone-specific alkaline phosphatase (bALP), osteocalcin, and calcium in comparison with the OVX group. In addition, AUR treatment reduced TRAP-positive osteoclasts and receptor activator of nuclear factor kappa-B ligand (RANKL). +. nuclear factor of activated T cells 1 (NFATc1). +. expression in the femoral body. Moreover, the expressions of initiators for osteoclastic resorption and bone matrix degradation were significantly (p < 0.05) regulated by AUR in the lumbar spine of the osteoporotic mice. Conclusion. AUR ameliorated bone loss by downregulating the RANKL/NFATc1 pathway, resulting in improvement of osteoporosis. In conclusion, AUR might be an ameliorative cure that alleviates bone loss in osteoporosis via inhibition of osteoclastic activity. Cite this article: Bone Joint Res 2022;11(5):304–316


Bone & Joint Research
Vol. 12, Issue 9 | Pages 590 - 597
20 Sep 2023
Uemura K Otake Y Takashima K Hamada H Imagama T Takao M Sakai T Sato Y Okada S Sugano N

Aims. This study aimed to develop and validate a fully automated system that quantifies proximal femoral bone mineral density (BMD) from CT images. Methods. The study analyzed 978 pairs of hip CT and dual-energy X-ray absorptiometry (DXA) measurements of the proximal femur (DXA-BMD) collected from three institutions. From the CT images, the femur and a calibration phantom were automatically segmented using previously trained deep-learning models. The Hounsfield units of each voxel were converted into density (mg/cm. 3. ). Then, a deep-learning model trained by manual landmark selection of 315 cases was developed to select the landmarks at the proximal femur to rotate the CT volume to the neutral position. Finally, the CT volume of the femur was projected onto the coronal plane, and the areal BMD of the proximal femur (CT-aBMD) was quantified. CT-aBMD correlated to DXA-BMD, and a receiver operating characteristic (ROC) analysis quantified the accuracy in diagnosing osteoporosis. Results. CT-aBMD was successfully measured in 976/978 hips (99.8%). A significant correlation was found between CT-aBMD and DXA-BMD (r = 0.941; p < 0.001). In the ROC analysis, the area under the curve to diagnose osteoporosis was 0.976. The diagnostic sensitivity and specificity were 88.9% and 96%, respectively, with the cutoff set at 0.625 g/cm. 2. . Conclusion. Accurate DXA-BMD measurements and diagnosis of osteoporosis were performed from CT images using the system developed herein. As the models are open-source, clinicians can use the proposed system to screen osteoporosis and determine the surgical strategy for hip surgery. Cite this article: Bone Joint Res 2023;12(9):590–597


Bone & Joint Research
Vol. 10, Issue 12 | Pages 820 - 829
15 Dec 2021
Schmidutz F Schopf C Yan SG Ahrend M Ihle C Sprecher C

Aims. The distal radius is a major site of osteoporotic bone loss resulting in a high risk of fragility fracture. This study evaluated the capability of a cortical index (CI) at the distal radius to predict the local bone mineral density (BMD). Methods. A total of 54 human cadaver forearms (ten singles, 22 pairs) (19 to 90 years) were systematically assessed by clinical radiograph (XR), dual-energy X-ray absorptiometry (DXA), CT, as well as high-resolution peripheral quantitative CT (HR-pQCT). Cortical bone thickness (CBT) of the distal radius was measured on XR and CT scans, and two cortical indices mean average (CBTavg) and gauge (CBTg) were determined. These cortical indices were compared to the BMD of the distal radius determined by DXA (areal BMD (aBMD)) and HR-pQCT (volumetric BMD (vBMD)). Pearson correlation coefficient (r) and intraclass correlation coefficient (ICC) were used to compare the results and degree of reliability. Results. The CBT could accurately be determined on XRs and highly correlated to those determined on CT scans (r = 0.87 to 0.93). The CBTavg index of the XRs significantly correlated with the BMD measured by DXA (r = 0.78) and HR-pQCT (r = 0.63), as did the CBTg index with the DXA (r = 0.55) and HR-pQCT (r = 0.64) (all p < 0.001). A high correlation of the BMD and CBT was observed between paired specimens (r = 0.79 to 0.96). The intra- and inter-rater reliability was excellent (ICC 0.79 to 0.92). Conclusion. The cortical index (CBTavg) at the distal radius shows a close correlation to the local BMD. It thus can serve as an initial screening tool to estimate the local bone quality if quantitative BMD measurements are unavailable, and enhance decision-making in acute settings on fracture management or further osteoporosis screening. Cite this article: Bone Joint Res 2021;10(12):820–829


The Bone & Joint Journal
Vol. 105-B, Issue 3 | Pages 254 - 260
1 Mar 2023
Bukowski BR Sandhu KP Bernatz JT Pickhardt PJ Binkley N Anderson PA Illgen R

Aims. Osteoporosis can determine surgical strategy for total hip arthroplasty (THA), and perioperative fracture risk. The aims of this study were to use hip CT to measure femoral bone mineral density (BMD) using CT X-ray absorptiometry (CTXA), determine if systematic evaluation of preoperative femoral BMD with CTXA would improve identification of osteopenia and osteoporosis compared with available preoperative dual-energy X-ray absorptiometry (DXA) analysis, and determine if improved recognition of low BMD would affect the use of cemented stem fixation. Methods. Retrospective chart review of a single-surgeon database identified 78 patients with CTXA performed prior to robotic-assisted THA (raTHA) (Group 1). Group 1 was age- and sex-matched to 78 raTHAs that had a preoperative hip CT but did not have CTXA analysis (Group 2). Clinical demographics, femoral fixation method, CTXA, and DXA data were recorded. Demographic data were similar for both groups. Results. Preoperative femoral BMD was available for 100% of Group 1 patients (CTXA) and 43.6% of Group 2 patients (DXA). CTXA analysis for all Group 1 patients preoperatively identified 13 osteopenic and eight osteoporotic patients for whom there were no available preoperative DXA data. Cemented stem fixation was used with higher frequency in Group 1 versus Group 2 (28.2% vs 14.3%, respectively; p = 0.030), and in all cases where osteoporosis was diagnosed, irrespective of technique (DXA or CTXA). Conclusion. Preoperative hip CT scans which are routinely obtained prior to raTHA can determine bone health, and thus guide femoral fixation strategy. Systematic preoperative evaluation with CTXA resulted in increased recognition of osteopenia and osteoporosis, and contributed to increased use of cemented femoral fixation compared with routine clinical care; in this small study, however, it did not impact short-term periprosthetic fracture risk. Cite this article: Bone Joint J 2023;105-B(3):254–260


Bone & Joint Research
Vol. 10, Issue 11 | Pages 734 - 741
1 Nov 2021
Cheng B Wen Y Yang X Cheng S Liu L Chu X Ye J Liang C Yao Y Jia Y Zhang F

Aims. Despite the interest in the association of gut microbiota with bone health, limited population-based studies of gut microbiota and bone mineral density (BMD) have been made. Our aim is to explore the possible association between gut microbiota and BMD. Methods. A total of 3,321 independent loci of gut microbiota were used to calculate the individual polygenic risk score (PRS) for 114 gut microbiota-related traits. The individual genotype data were obtained from UK Biobank cohort. Linear regressions were then conducted to evaluate the possible association of gut microbiota with L1-L4 BMD (n = 4,070), total BMD (n = 4,056), and femur total BMD (n = 4,054), respectively. PLINK 2.0 was used to detect the single-nucleotide polymorphism (SNP) × gut microbiota interaction effect on the risks of L1-L4 BMD, total BMD, and femur total BMD, respectively. Results. We detected five, three, and seven candidate gut microbiota-related traits for L1-L4 BMD, total BMD, and femur BMD, respectively, such as genus Dialister (p = 0.004) for L1-L4 BMD, and genus Eisenbergiella (p = 0.046) for total BMD. We also detected two common gut microbiota-related traits shared by L1-L4 BMD, total BMD, and femur total BMD, including genus Escherichia Shigella and genus Lactococcus. Interaction analysis of BMD detected several genes that interacted with gut microbiota, such as phospholipase D1 (PLD1) and endomucin (EMCN) interacting with genus Dialister in total BMD, and COL12A1 and Discs Large MAGUK Scaffold Protein 2 (DLG2) interacting with genus Lactococcus in femur BMD. Conclusion. Our results suggest associations between gut microbiota and BMD, which will be helpful to further explore the regulation mechanism and intervention gut microbiota of BMD. Cite this article: Bone Joint Res 2021;10(11):734–741


The Bone & Joint Journal
Vol. 106-B, Issue 6 | Pages 548 - 554
1 Jun 2024
Ohyama Y Minoda Y Masuda S Sugama R Ohta Y Nakamura H

Aims. The aim of this study was to compare the pattern of initial fixation and changes in periprosthetic bone mineral density (BMD) between patients who underwent total hip arthroplasty (THA) using a traditional fully hydroxyapatite (HA)-coated stem (T-HA group) and those with a newly introduced fully HA-coated stem (N-HA group). Methods. The study included 36 patients with T-HA stems and 30 with N-HA stems. Dual-energy X-ray absorptiometry was used to measure the change in periprosthetic BMD, one and two years postoperatively. The 3D contact between the stem and femoral cortical bone was evaluated using a density-mapping system, and clinical assessment, including patient-reported outcome measurements, was recorded. Results. There were significantly larger contact areas in Gruen zones 3, 5, and 6 in the N-HA group than in the T-HA group. At two years postoperatively, there was a significant decrease in BMD around the proximal-medial femur (zone 6) in the N-HA group and a significant increase in the T-HA group. BMD changes in both groups correlated with BMI or preoperative lumbar BMD rather than with the extent of contact with the femoral cortical bone. Conclusion. The N-HA-coated stem showed a significantly larger contact area, indicating a distal fixation pattern, compared with the traditional fully HA-coated stem. The T-HA-coated stem showed better preservation of periprosthetic BMD, two years postoperatively. Surgeons should consider these patterns of fixation and differences in BMD when selecting fully HA-coated stems for THA, to improve the long-term outcomes. Cite this article: Bone Joint J 2024;106-B(6):548–554


Bone & Joint Research
Vol. 12, Issue 5 | Pages 339 - 351
23 May 2023
Tan J Liu X Zhou M Wang F Ma L Tang H He G Kang X Bian X Tang K

Aims. Mechanical stimulation is a key factor in the development and healing of tendon-bone insertion. Treadmill training is an important rehabilitation treatment. This study aims to investigate the benefits of treadmill training initiated on postoperative day 7 for tendon-bone insertion healing. Methods. A tendon-bone insertion injury healing model was established in 92 C57BL/6 male mice. All mice were divided into control and training groups by random digital table method. The control group mice had full free activity in the cage, and the training group mice started the treadmill training on postoperative day 7. The quality of tendon-bone insertion healing was evaluated by histology, immunohistochemistry, reverse transcription quantitative polymerase chain reaction, Western blotting, micro-CT, micro-MRI, open field tests, and CatWalk gait and biomechanical assessments. Results. Our results showed a significantly higher tendon-bone insertion histomorphological score in the training group, and the messenger RNA and protein expression levels of type II collagen (COL2A1), SOX9, and type X collagen (COL10A1) were significantly elevated. Additionally, tendon-bone insertion resulted in less scar hyperplasia after treadmill training, the bone mineral density (BMD) and bone volume/tissue volume (BV/TV) were significantly improved, and the force required to induce failure became stronger in the training group. Functionally, the motor ability, limb stride length, and stride frequency of mice with tendon-bone insertion injuries were significantly improved in the training group compared with the control group. Conclusion. Treadmill training initiated on postoperative day 7 is beneficial to tendon-bone insertion healing, promoting biomechanical strength and motor function. Our findings are expected to guide clinical rehabilitation training programmes. Cite this article: Bone Joint Res 2023;12(5):339–351


Bone & Joint Research
Vol. 11, Issue 4 | Pages 229 - 238
11 Apr 2022
Jaeger S Eissler M Schwarze M Schonhoff M Kretzer JP Bitsch RG

Aims. One of the main causes of tibial revision surgery for total knee arthroplasty is aseptic loosening. Therefore, stable fixation between the tibial component and the cement, and between the tibial component and the bone, is essential. A factor that could influence the implant stability is the implant design, with its different variations. In an existing implant system, the tibial component was modified by adding cement pockets. The aim of this experimental in vitro study was to investigate whether additional cement pockets on the underside of the tibial component could improve implant stability. The relative motion between implant and bone, the maximum pull-out force, the tibial cement mantle, and a possible path from the bone marrow to the metal-cement interface were determined. Methods. A tibial component with (group S: Attune S+) and without (group A: Attune) additional cement pockets was implanted in 15 fresh-frozen human leg pairs. The relative motion was determined under dynamic loading (extension-flexion 20° to 50°, load-level 1,200 to 2,100 N) with subsequent determination of the maximum pull-out force. In addition, the cement mantle was analyzed radiologically for possible defects, the tibia base cement adhesion, and preoperative bone mineral density (BMD). Results. The BMD showed no statistically significant difference between both groups. Group A showed for all load levels significantly higher maximum relative motion compared to group S for 20° and 50° flexion. Group S improved the maximum failure load significantly compared to group A without additional cement pockets. Group S showed a significantly increased cement adhesion compared to group A. The cement penetration and cement mantle defect analysis showed no significant differences between both groups. Conclusion. From a biomechanical point of view, the additional cement pockets of the component have improved the fixation performance of the implant. Cite this article: Bone Joint Res 2022;11(4):229–238


The Bone & Joint Journal
Vol. 104-B, Issue 10 | Pages 1132 - 1141
1 Oct 2022
Holm-Glad T Røkkum M Röhrl SM Roness S Godang K Reigstad O

Aims. To analyze the short-term outcome of two types of total wrist arthroplasty (TWA) in terms of wrist function, migration, and periprosthetic bone behaviour. Methods. A total of 40 patients suffering from non-rheumatoid wrist arthritis were enrolled in a randomized controlled trial comparing the ReMotion and Motec TWAs. Patient-rated and functional outcomes, radiological changes, blood metal ion levels, migration measured by model-based radiostereometric analysis (RSA), bone mineral density (BMD) measured by dual-energy X-ray absorptiometry (DXA), complications, loosening, and revision rates at two years were compared. Results. Patient-Rated Wrist and Hand Evaluation (PRWHE) scores, abbreviated version of the Disabilities of the Arm, Shoulder and Hand questionnaire (QuickDASH) scores, and pain improved similarly and significantly in both groups. Wrist motion improved significantly in the Motec group only, and forearm rotation in the ReMotion group only. Cobalt (Co) and chromium (Cr) blood ion levels were significantly higher in the metal-on-metal (MoM) Motec group than in the metal-on-polyethylene (MoP) ReMotion group. Mean total translation was 0.65 mm (95% confidence interval (CI) 0.26 to 1.12) and 0.27 mm (95% CI 0.14 to 0.47) for the ReMotion carpal and radial components, and 0.32 mm (95% CI 0.22 to 0.45) and 0.26 mm (95% CI 0.20 to 0.34) for the Motec metacarpal and radial components, respectively. Apart from dorsal and volar tilts, which were significantly higher for the radial ReMotion than for the Motec component, no significant differences in absolute migration occurred. BMD around the radial components never returned to baseline. Almost one-third of patients required reoperation due to complications. Two ReMotion implants were revised to Motec TWAs due to carpal component loosening, and three Motec MoM articulations were revised to metal-on-polyether ether ketone due to painful synovitis. Conclusion. Both implants provided matched function and were stable at short-term follow-up, but with a high complication rate. This procedure should be restricted to specialist centres undertaking prospective analysis until its role is clarified. Cite this article: Bone Joint J 2022;104-B(10):1132–1141


Aims. The aim of this study was to compare the mid-term patient-reported outcome, bone remodelling, and migration of a short stem (Collum Femoris Preserving; CFP) with a conventional uncemented stem (Corail). Methods. Of 81 patients who were initially enrolled, 71 were available at five years’ follow-up. The outcomes at two years have previously been reported. The primary outcome measure was the clinical result assessed using the Oxford Hip Score (OHS). Secondary outcomes were the migration of the stem, measured using radiostereometric analysis (RSA), change of bone mineral density (BMD) around the stem, the development of radiolucent lines, and additional patient-reported outcome measures (PROMs). Results. There were no statistically significant differences between the groups regarding PROMs (median OHS (CFP 45 (interquartile range (IQR) 35 to 48); Corail 45 (IQR 40 to 48); p = 0.568). RSA showed stable stems in both groups, with little or no further subsidence between two and five years. Resorption of the femoral neck was evident in nine patients in the CFP group and in none of the 15 Corail stems with a collar that could be studied. Dual X-ray absorbiometry showed a significantly higher loss of BMD in the proximal Gruen zones in the CFP group (mean changes in BMD: Gruen zone 1, CFP -9.5 (95% confidence interval (CI) -14.8 to -4.2), Corail 1.0 (95% CI 3.4 to 5.4); Gruen zone 7, CFP -23.0 (95% CI -29.4 to -16.6), Corail -7.2 (95% CI -15.9 to 1.4). Two CFP stems were revised before two years’ follow-up due to loosening, and one Corail stem was revised after two years due to chronic infection. Conclusion. The CFP stem has a similar clinical outcome and subsidence pattern when compared with the Corail stem. More pronounced proximal stress-shielding was seen with the CFP stem, suggesting diaphyseal fixation, and questioning its femoral neck-sparing properties in the long term. Cite this article: Bone Joint J 2022;104-B(5):581–588


Bone & Joint Open
Vol. 3, Issue 3 | Pages 261 - 267
22 Mar 2022
Abe S Kashii M Shimada T Suzuki K Nishimoto S Nakagawa R Horiki M Yasui Y Namba J Kuriyama K

Aims. Low-energy distal radius fractures (DRFs) are the most common upper arm fractures correlated with bone fragility. Vitamin D deficiency is an important risk factor associated with DRFs. However, the relationship between DRF severity and vitamin D deficiency is not elucidated. Therefore, this study aimed to identify the correlation between DRF severity and serum 25-hydroxyvitamin-D level, which is an indicator of vitamin D deficiency. Methods. This multicentre retrospective observational study enrolled 122 female patients aged over 45 years with DRFs with extension deformity. DRF severity was assessed by three independent examiners using 3D CT. Moreover, it was categorized based on the AO classification, and the degree of articular and volar cortex comminution was evaluated. Articular comminution was defined as an articular fragment involving three or more fragments, and volar cortex comminution as a fracture in the volar cortex of the distal fragment. Serum 25-hydroxyvitamin-D level, bone metabolic markers, and bone mineral density (BMD) at the lumbar spine, hip, and wrist were evaluated six months after injury. According to DRF severity, serum 25-hydroxyvitamin-D level, parameters correlated with bone metabolism, and BMD was compared. Results. The articular comminuted group (n = 28) had a significantly lower median serum 25-hydroxyvitamin-D level than the non-comminuted group (n = 94; 13.4 ng/ml (interquartile range (IQR) 9.8 to 17.3) vs 16.2 ng/ml (IQR 12.5 to 20.4); p = 0.005). The AO classification and volar cortex comminution were not correlated with the serum 25-hydroxyvitamin-D level. Bone metabolic markers and BMD did not significantly differ in terms of DRF severities. Conclusion. Articular comminuted DRF, referred to as AO C3 fracture, is significantly associated with low serum 25-hydroxyvitamin-D levels. Therefore, vitamin D. 3. supplementation for vitamin D deficiency might prevent articular comminuted DRFs. Nevertheless, further studies must be conducted to validate the results of the current study. Cite this article: Bone Jt Open 2022;3(3):261–267


Bone & Joint Research
Vol. 12, Issue 7 | Pages 423 - 432
6 Jul 2023
Xie H Wang N He H Yang Z Wu J Yang T Wang Y

Aims

Previous studies have suggested that selenium as a trace element is involved in bone health, but findings related to the specific effect of selenium on bone health remain inconclusive. Thus, we performed a meta-analysis by including all the relevant studies to elucidate the association between selenium status (dietary intake or serum selenium) and bone health indicators (bone mineral density (BMD), osteoporosis (OP), or fracture).

Methods

PubMed, Embase, and Cochrane Library were systematically searched to retrieve relevant articles published before 15 November 2022. Studies focusing on the correlation between selenium and BMD, OP, or fracture were included. Effect sizes included regression coefficient (β), weighted mean difference (WMD), and odds ratio (OR). According to heterogeneity, the fixed-effect or random-effect model was used to assess the association between selenium and bone health.


Bone & Joint Research
Vol. 11, Issue 8 | Pages 528 - 540
1 Aug 2022
Dong W Postlethwaite BC Wheller PA Brand D Jiao Y Li W Myers LK Gu W

Aims

This study investigated the effects of β-caryophyllene (BCP) on protecting bone from vitamin D deficiency in mice fed on a diet either lacking (D-) or containing (D+) vitamin D.

Methods

A total of 40 female mice were assigned to four treatment groups (n = 10/group): D+ diet with propylene glycol control, D+ diet with BCP, D-deficient diet with control, and D-deficient diet with BCP. The D+ diet is a commercial basal diet, while the D-deficient diet contains 0.47% calcium, 0.3% phosphorus, and no vitamin D. All the mice were housed in conditions without ultraviolet light. Bone properties were evaluated by X-ray micro-CT. Serum levels of klotho were measured by enzyme-linked immunosorbent assay.


Bone & Joint Research
Vol. 13, Issue 4 | Pages 184 - 192
18 Apr 2024
Morita A Iida Y Inaba Y Tezuka T Kobayashi N Choe H Ike H Kawakami E

Aims. This study was designed to develop a model for predicting bone mineral density (BMD) loss of the femur after total hip arthroplasty (THA) using artificial intelligence (AI), and to identify factors that influence the prediction. Additionally, we virtually examined the efficacy of administration of bisphosphonate for cases with severe BMD loss based on the predictive model. Methods. The study included 538 joints that underwent primary THA. The patients were divided into groups using unsupervised time series clustering for five-year BMD loss of Gruen zone 7 postoperatively, and a machine-learning model to predict the BMD loss was developed. Additionally, the predictor for BMD loss was extracted using SHapley Additive exPlanations (SHAP). The patient-specific efficacy of bisphosphonate, which is the most important categorical predictor for BMD loss, was examined by calculating the change in predictive probability when hypothetically switching between the inclusion and exclusion of bisphosphonate. Results. Time series clustering allowed us to divide the patients into two groups, and the predictive factors were identified including patient- and operation-related factors. The area under the receiver operating characteristic (ROC) curve (AUC) for the BMD loss prediction averaged 0.734. Virtual administration of bisphosphonate showed on average 14% efficacy in preventing BMD loss of zone 7. Additionally, stem types and preoperative triglyceride (TG), creatinine (Cr), estimated glomerular filtration rate (eGFR), and creatine kinase (CK) showed significant association with the estimated patient-specific efficacy of bisphosphonate. Conclusion. Periprosthetic BMD loss after THA is predictable based on patient- and operation-related factors, and optimal prescription of bisphosphonate based on the prediction may prevent BMD loss. Cite this article: Bone Joint Res 2024;13(4):184–192


Aims

This study examined whether systemic administration of melatonin would have different effects on osseointegration in ovariectomized (OVX) rats, depending on whether this was administered during the day or night.

Methods

In this study, a titanium rod was implanted in the medullary cavity of one femoral metaphysis in OVX rats, and then the rats were randomly divided into four groups: Sham group (Sham, n = 10), OVX rat group (OVX, n = 10), melatonin day treatment group (OVX + MD, n = 10), and melatonin night treatment group (OVX + MN, n = 10). The OVX + MD and OVX + MN rats were treated with 30 mg/kg/day melatonin at 9 am and 9 pm, respectively, for 12 weeks. At the end of the research, the rats were killed to obtain bilateral femora and blood samples for evaluation.


Bone & Joint Research
Vol. 12, Issue 2 | Pages 147 - 154
20 Feb 2023
Jia Y Qi X Ma M Cheng S Cheng B Liang C Guo X Zhang F

Aims. Osteoporosis (OP) is a metabolic bone disease, characterized by a decrease in bone mineral density (BMD). However, the research of regulatory variants has been limited for BMD. In this study, we aimed to explore novel regulatory genetic variants associated with BMD. Methods. We conducted an integrative analysis of BMD genome-wide association study (GWAS) and regulatory single nucleotide polymorphism (rSNP) annotation information. Firstly, the discovery GWAS dataset and replication GWAS dataset were integrated with rSNP annotation database to obtain BMD associated SNP regulatory elements and SNP regulatory element-target gene (E-G) pairs, respectively. Then, the common genes were further subjected to HumanNet v2 to explore the biological effects. Results. Through discovery and replication integrative analysis for BMD GWAS and rSNP annotation database, we identified 36 common BMD-associated genes for BMD irrespective of regulatory elements, such as FAM3C (p. discovery GWAS. = 1.21 × 10. -25. , p. replication GWAS. = 1.80 × 10. -12. ), CCDC170 (p. discovery GWAS. = 1.23 × 10. -11. , p. replication GWAS. = 3.22 × 10. -9. ), and SOX6 (p. discovery GWAS. = 4.41 × 10. -15. , p. replication GWAS. = 6.57 × 10. -14. ). Then, for the 36 common target genes, multiple gene ontology (GO) terms were detected for BMD such as positive regulation of cartilage development (p = 9.27 × 10. -3. ) and positive regulation of chondrocyte differentiation (p = 9.27 × 10. -3. ). Conclusion. We explored the potential roles of rSNP in the genetic mechanisms of BMD and identified multiple candidate genes. Our study results support the implication of regulatory genetic variants in the development of OP. Cite this article: Bone Joint Res 2023;12(2):147–154


Bone & Joint Research
Vol. 11, Issue 12 | Pages 873 - 880
1 Dec 2022
Watanabe N Miyatake K Takada R Ogawa T Amano Y Jinno T Koga H Yoshii T Okawa A

Aims

Osteoporosis is common in total hip arthroplasty (THA) patients. It plays a substantial factor in the surgery’s outcome, and previous studies have revealed that pharmacological treatment for osteoporosis influences implant survival rate. The purpose of this study was to examine the prevalence of and treatment rates for osteoporosis prior to THA, and to explore differences in osteoporosis-related biomarkers between patients treated and untreated for osteoporosis.

Methods

This single-centre retrospective study included 398 hip joints of patients who underwent THA. Using medical records, we examined preoperative bone mineral density measures of the hip and lumbar spine using dual energy X-ray absorptiometry (DXA) scans and the medications used to treat osteoporosis at the time of admission. We also assessed the following osteoporosis-related biomarkers: tartrate-resistant acid phosphatase 5b (TRACP-5b); total procollagen type 1 amino-terminal propeptide (total P1NP); intact parathyroid hormone; and homocysteine.


Bone & Joint Research
Vol. 10, Issue 12 | Pages 830 - 839
15 Dec 2021
Robertson G Wallace R Simpson AHRW Dawson SP

Aims. Assessment of bone mineral density (BMD) with dual-energy X-ray absorptiometry (DXA) is a well-established clinical technique, but it is not available in the acute trauma setting. Thus, it cannot provide a preoperative estimation of BMD to help guide the technique of fracture fixation. Alternative methods that have been suggested for assessing BMD include: 1) cortical measures, such as cortical ratios and combined cortical scores; and 2) aluminium grading systems from preoperative digital radiographs. However, limited research has been performed in this area to validate the different methods. The aim of this study was to investigate the evaluation of BMD from digital radiographs by comparing various methods against DXA scanning. Methods. A total of 54 patients with distal radial fractures were included in the study. Each underwent posteroanterior (PA) and lateral radiographs of the injured wrist with an aluminium step wedge. Overall 27 patients underwent routine DXA scanning of the hip and lumbar spine, with 13 undergoing additional DXA scanning of the uninjured forearm. Analysis of radiographs was performed on ImageJ and Matlab with calculations of cortical measures, cortical indices, combined cortical scores, and aluminium equivalent grading. Results. Cortical measures showed varying correlations with the forearm DXA results (range: Pearson correlation coefficient (r) = 0.343 (p = 0.251) to r = 0.521 (p = 0.068)), with none showing statistically significant correlations. Aluminium equivalent grading showed statistically significant correlations with the forearm DXA of the corresponding region of interest (p < 0.017). Conclusion. Cortical measures, cortical indices, and combined cortical scores did not show a statistically significant correlation to forearm DXA measures. Aluminium-equivalent is an easily applicable method for estimation of BMD from digital radiographs in the preoperative setting. Cite this article: Bone Joint Res 2021;10(12):830–839


Bone & Joint Research
Vol. 10, Issue 12 | Pages 840 - 843
15 Dec 2021
Al-Hourani K Tsang SJ Simpson AHRW


The Bone & Joint Journal
Vol. 103-B, Issue 5 | Pages 872 - 880
1 May 2021
Young PS Macarico DT Silverwood RK Farhan-Alanie OM Mohammed A Periasamy K Nicol A Meek RMD

Aims. Uncemented metal acetabular components show good osseointegration, but material stiffness causes stress shielding and retroacetabular bone loss. Cemented monoblock polyethylene components load more physiologically; however, the cement bone interface can suffer fibrous encapsulation and loosening. It was hypothesized that an uncemented titanium-sintered monoblock polyethylene component may offer the optimum combination of osseointegration and anatomical loading. Methods. A total of 38 patients were prospectively enrolled and received an uncemented monoblock polyethylene acetabular (pressfit) component. This single cohort was then retrospectively compared with previously reported randomized cohorts of cemented monoblock (cemented) and trabecular metal (trabecular) acetabular implants. The primary outcome measure was periprosthetic bone density using dual-energy x-ray absorptiometry over two years. Secondary outcomes included radiological and clinical analysis. Results. Although there were differences in the number of males and females in each group, no significant sex bias was noted (p = 0.080). Furthermore, there was no significant difference in age (p = 0.910) or baseline lumbar bone mineral density (BMD) (p = 0.998) found between any of the groups (pressfit, cemented, or trabecular). The pressfit implant initially behaved like the trabecular component with an immediate fall in BMD in the inferior and medial regions, with preserved BMD laterally, suggesting lateral rim loading. However, the pressfit component subsequently showed a reversal in BMD medially with recovery back towards baseline, and a continued rise in lateral BMD. This would suggest that the pressfit component begins to reload the medial bone over time, more akin to the cemented component. Analysis of postoperative radiographs revealed no pressfit component subsidence or movement up to two years postoperatively (100% interobserver reliability). Medial defects seen immediately postoperatively in five cases had completely resolved by two years in four patients. Conclusion. Initially, the uncemented monoblock component behaved similarly to the rigid trabecular metal component with lateral rim loading; however, over two years this changed to more closely resemble the loading pattern of a cemented polyethylene component with increasing medial pelvic loading. This indicates that the uncemented monoblock acetabular component may result in optimized fixation and preservation of retroacetabular bone stock. Cite this article: Bone Joint J 2021;103-B(5):872–880


Bone & Joint Research
Vol. 9, Issue 10 | Pages 731 - 741
28 Oct 2020
He Z Nie P Lu J Ling Y Guo J Zhang B Hu J Liao J Gu J Dai B Feng Z

Aims. Osteoarthritis (OA) is a disabling joint disorder and mechanical loading is an important pathogenesis. This study aims to investigate the benefits of less mechanical loading created by intermittent tail suspension for knee OA. Methods. A post-traumatic OA model was established in 20 rats (12 weeks old, male). Ten rats were treated with less mechanical loading through intermittent tail suspension, while another ten rats were treated with normal mechanical loading. Cartilage damage was determined by gross appearance, Safranin O/Fast Green staining, and immunohistochemistry examinations. Subchondral bone changes were analyzed by micro-CT and tartrate-resistant acid phosphatase (TRAP) staining, and serum inflammatory cytokines were evaluated by enzyme-linked immunosorbent assay (ELISA). Results. Our radiographs showed that joint space was significantly enlarged in rats with less mechanical loading. Moreover, cartilage destruction was attenuated in the less mechanical loading group with lower histological damage scores, and lower expression of a disintegrin and metalloproteinase with thrombospondin motifs (ADAMTS)-5, matrix metalloproteinase (MMP)-3, and MMP-13. In addition, subchondral bone abnormal changes were ameliorated in OA rats with less mechanical loading, as reduced bone mineral density (BMD), bone volume/tissue volume (BV/TV), and number of osteophytes and osteoclasts in the subchondral bone were observed. Finally, the level of serum inflammatory cytokines was significantly downregulated in the less mechanical loading group compared with the normal mechanical loading group, as well as the expression of NACHT, LRR, and PYD domains-containing protein 3 (NLRP3), caspase-1, and interleukin 1β (IL-1β) in the cartilage. Conclusion. Less mechanical loading alleviates cartilage destruction, subchondral bone changes, and secondary inflammation in OA joints. This study provides fundamental insights into the benefit of non-weight loading rest for patients with OA. Cite this article: Bone Joint Res 2020;9(10):731–741


Objectives. MicroRNAs (miRNAs) have been reported as key regulators of bone formation, signalling, and repair. Fracture healing is a proliferative physiological process where the body facilitates the repair of a bone fracture. The aim of our study was to explore the effects of microRNA-186 (miR-186) on fracture healing through the bone morphogenetic protein (BMP) signalling pathway by binding to Smad family member 6 (SMAD6) in a mouse model of femoral fracture. Methods. Microarray analysis was adopted to identify the regulatory miR of SMAD6. 3D micro-CT was performed to assess the bone volume (BV), bone volume fraction (BVF, BV/TV), and bone mineral density (BMD), followed by a biomechanical test for maximum load, maximum radial degrees, elastic radial degrees, and rigidity of the femur. The positive expression of SMAD6 in fracture tissues was measured. Moreover, the miR-186 level, messenger RNA (mRNA) level, and protein levels of SMAD6, BMP-2, and BMP-7 were examined. Results. MicroRNA-186 was predicted to regulate SMAD6. Furthermore, SMAD6 was verified as a target gene of miR-186. Overexpressed miR-186 and SMAD6 silencing resulted in increased callus formation, BMD and BV/TV, as well as maximum load, maximum radial degrees, elastic radial degrees, and rigidity of the femur. In addition, the mRNA and protein levels of SMAD6 were decreased, while BMP-2 and BMP-7 levels were elevated in response to upregulated miR-186 and SMAD6 silencing. Conclusion. In conclusion, the study indicated that miR-186 could activate the BMP signalling pathway to promote fracture healing by inhibiting SMAD6 in a mouse model of femoral fracture. Cite this article: Bone Joint Res 2019;8:550–562


The Bone & Joint Journal
Vol. 103-B, Issue 4 | Pages 644 - 649
1 Apr 2021
Alsousou J Oragu E Martin A Strickland L Newman S Kendrick B Taylor A Glyn-Jones S

Aims. The aim of this prospective cohort study was to evaluate the early migration of the TriFit cementless proximally coated tapered femoral stem using radiostereometric analysis (RSA). Methods. A total of 21 patients (eight men and 13 women) undergoing primary total hip arthroplasty (THA) for osteoarthritis of the hip were recruited in this study and followed up for two years. Two patients were lost to follow-up. All patients received a TriFit stem and Trinity Cup with a vitamin E-infused highly cross-linked ultra-high molecular weight polyethylene liner. Radiographs for RSA were taken postoperatively and then at three, 12, and 24 months. Oxford Hip Score (OHS), EuroQol five-dimension questionnaire (EQ-5D), and adverse events were reported. Results. At two years, the mean subsidence of the head and tip for the TriFit stem was 0.38 mm (SD 0.32) and 0.52 mm (SD 0.36), respectively. The total migration of the head and tip was 0.55 mm (SD 0.32) and 0.71 mm (SD 0.38), respectively. There were no statistically significant differences between the three to 12 months' migration (p = 0.105) and 12 to 24 months' migration (p = 0.694). The OHS and EQ-5D showed significant improvements at two years. Conclusion. The results of this study suggest that the TriFit femoral stem achieves initial stability and is likely to be stable in the mid and long term. A long-term outcome study is required to assess late mechanisms of failure and the effects of bone mineral density (BMD) related changes. Cite this article: Bone Joint J 2021;103-B(4):644–649


Bone & Joint Research
Vol. 7, Issue 7 | Pages 468 - 475
1 Jul 2018
He Q Sun H Shu L Zhu Y Xie X Zhan Y Luo C

Objectives. Researchers continue to seek easier ways to evaluate the quality of bone and screen for osteoporosis and osteopenia. Until recently, radiographic images of various parts of the body, except the distal femur, have been reappraised in the light of dual-energy X-ray absorptiometry (DXA) findings. The incidence of osteoporotic fractures around the knee joint in the elderly continues to increase. The aim of this study was to propose two new radiographic parameters of the distal femur for the assessment of bone quality. Methods. Anteroposterior radiographs of the knee and bone mineral density (BMD) and T-scores from DXA scans of 361 healthy patients were prospectively analyzed. The mean cortical bone thickness (CBTavg) and the distal femoral cortex index (DFCI) were the two parameters that were proposed and measured. Intra- and interobserver reliabilities were assessed. Correlations between the BMD and T-score and these parameters were investigated and their value in the diagnosis of osteoporosis and osteopenia was evaluated. Results. The DFCI, as a ratio, had higher reliability than the CBTavg. Both showed significant correlation with BMD and T-score. When compared with DFCI, CBTavg showed better correlation and was better for predicting osteoporosis and osteopenia. Conclusion. The CBTavg and DFCI are simple and reliable screening tools for the prediction of osteoporosis and osteopenia. The CBTavg is more accurate but the DFCI is easier to use in clinical practice. Cite this article: Q-F. He, H. Sun, L-Y. Shu, Y. Zhu, X-T. Xie, Y. Zhan, C-F. Luo. Radiographic predictors for bone mineral loss: Cortical thickness and index of the distal femur. Bone Joint Res 2018;7:468–475. DOI: 10.1302/2046-3758.77.BJR-2017-0332.R1


Bone & Joint Research
Vol. 10, Issue 1 | Pages 51 - 59
1 Jan 2021
Li J Ho WTP Liu C Chow SK Ip M Yu J Wong HS Cheung W Sung JJY Wong RMY

Aims. The effect of the gut microbiota (GM) and its metabolite on bone health is termed the gut-bone axis. Multiple studies have elucidated the mechanisms but findings vary greatly. A systematic review was performed to analyze current animal models and explore the effect of GM on bone. Methods. Literature search was performed on PubMed and Embase databases. Information on the types and strains of animals, induction of osteoporosis, intervention strategies, determination of GM, assessment on bone mineral density (BMD) and bone quality, and key findings were extracted. Results. A total of 30 studies were included, of which six studies used rats and 24 studies used mice. Osteoporosis or bone loss was induced in 14 studies. Interventions included ten with probiotics, three with prebiotics, nine with antibiotics, two with short-chain fatty acid (SCFA), six with vitamins and proteins, two with traditional Chinese medicine (TCM), and one with neuropeptide Y1R antagonist. In general, probiotics, prebiotics, nutritional interventions, and TCM were found to reverse the GM dysbiosis and rescue bone loss. Conclusion. Despite the positive therapeutic effect of probiotics, prebiotics, and nutritional or pharmaceutical interventions on osteoporosis, there is still a critical knowledge gap regarding the role of GM in rescuing bone loss and its related pathways. Cite this article: Bone Joint Res 2021;10(1):51–59


Bone & Joint Research
Vol. 9, Issue 3 | Pages 139 - 145
1 Mar 2020
Guebeli A Platz EA Paller CJ McGlynn KA Rohrmann S

Aims. To examine the relationship of sex steroid hormones with osteopenia in a nationally representative sample of men in the USA. Methods. Data on bone mineral density (BMD), serum sex hormones, dairy consumption, smoking status, and body composition were available for 806 adult male participants of the cross-sectional National Health and Nutrition Examination Survey (NHANES, 1999-2004). We estimated associations between quartiles of total and estimated free oestradiol (E2) and testosterone (T) and osteopenia (defined as 1 to 2.5 SD below the mean BMD for healthy 20- to 29-year-old men) by applying sampling weights and using multivariate-adjusted logistic regression. We then estimated the association between serum hormone concentrations and osteopenia by percentage of body fat, frequency of dairy intake, cigarette smoking status, age, and race/ethnicity. Results. Men in the lowest quartile of total E2 concentrations (< 21.52 pg/ml) had greater odds of osteopenia compared with men in the highest quartile (odds ratio (OR) 2.29, 95% confidence interval (CI) 1.11 to 4.73; p-trend = 0.030). Total and free T were not associated with osteopenia. Low total E2 concentrations were associated with greater odds of osteopenia among non-daily dairy consumers (p-trend = 0.046), current or former smokers (p-trend = 0.032), and younger men (p-trend = 0.031). No differences were observed by race/ethnicity and obesity. Conclusion. In this nationally representative study of the USA, men with lower total E2 were more likely to have osteopenia, which was particularly evident among younger men, men with less-than-daily dairy consumption, and current or former smokers. Cite this article:Bone Joint Res. 2020;9(3):139–145


The Bone & Joint Journal
Vol. 103-B, Issue 7 Supple B | Pages 73 - 77
1 Jul 2021
Lawrie CM Barrack RL Nunley RM

Aims. Dual mobility (DM) implants have been shown to reduce the dislocation rate after total hip arthroplasty (THA), but there remain concerns about the use of cobalt chrome liners inserted into titanium shells. The aim of this study was to assess the clinical outcomes, metal ion levels, and periprosthetic femoral bone mineral density (BMD) at mid-term follow-up in young, active patients receiving a modular DM THA. Methods. This was a prospective study involving patients aged < 65 years, with a BMI of < 35 kg/m. 2. , and University of California, Los Angeles activity score of > 6 who underwent primary THA with a modular cobalt chrome acetabular liner, highly cross-linked polyethylene mobile bearing, and a cementless titanium femoral stem. Patient-reported outcome measures, whole blood metal ion levels (μg/l), and periprosthetic femoral BMD were measured at baseline and at one, two, and five years postoperatively. The results two years postoperatively for this cohort have been previously reported. Results. A total of 43 patients were enrolled. At minimum follow-up of five years, 23 (53.4%) returned for clinical and radiological review, 25 (58.1%) had metal ion analysis performed, 19 (44.2%) underwent dual energy x-ray absorptiometry scans, and 25 (58%) completed a pain-drawing questionnaire. The mean modified Harris Hip Scores improved significantly from 54.8 (SD 19) preoperatively to 93.08 (SD 10.5) five years postoperatively (p < 0.001). One patient was revised for aseptic acetabular loosening. The mean cobalt levels increased from 0.065 μg/l (SD 0.03) to 0.08 (SD 0.05) and the mean titanium levels increased from 0.35 (SD 0.13) to 0.78 (SD 0.29). The femoral BMD ratio decreased in Gruen Zone 1 (91.9%) at five years postoperatively compared with the baseline scores at six weeks potoperatively. The femoral BMD ratio was maintained in Gruen zones 2 to 7. Conclusion. The use of a modular DM component and a cementless, tapered femoral stem shows excellent mid-term survivorship with minimal concerns for corrosion and metal ion release in a cohort of young, active patients undergoing primary THA. Cite this article: Bone Joint J 2021;103-B(7 Supple B):73–77


Bone & Joint Research
Vol. 9, Issue 10 | Pages 675 - 688
1 Oct 2020
Shao L Gou Y Fang J Hu Y Lian Q Zhang Y Wang Y Tian F Zhang L

Aims. Parathyroid hormone (PTH) (1-34) exhibits potential in preventing degeneration in both cartilage and subchondral bone in osteoarthritis (OA) development. We assessed the effects of PTH (1-34) at different concentrations on bone and cartilage metabolism in a collagenase-induced mouse model of OA and examined whether PTH (1-34) affects the JAK2/STAT3 signalling pathway in this process. Methods. Collagenase-induced OA was established in C57Bl/6 mice. Therapy with PTH (1-34) (10 μg/kg/day or 40 μg/kg/day) was initiated immediately after surgery and continued for six weeks. Cartilage pathology was evaluated by gross visual, histology, and immunohistochemical assessments. Cell apoptosis was analyzed by TUNEL staining. Microcomputed tomography (micro-CT) was used to evaluate the bone mass and the microarchitecture in subchondral bone. Results. Enhanced matrix catabolism, increased apoptosis of chondrocytes in cartilage, and overexpressed JAK2/STAT3 and p-JAK2/p-STAT3 were observed in cartilage in this model. All of these changes were prevented by PTH (1-34) treatment, with no significant difference between the low-dose and high-dose groups. Micro-CT analysis indicated that bone mineral density (BMD), bone volume/trabecular volume (BV/TV), and trabecular thickness (Tb.Th) levels were significantly lower in the OA group than those in the Sham, PTH 10 μg, and PTH 40 μg groups, but these parameters were significantly higher in the PTH 40 μg group than in the PTH 10 μg group. Conclusion. Intermittent administration of PTH (1-34) exhibits protective effects on both cartilage and subchondral bone in a dose-dependent manner on the latter in a collagenase-induced OA mouse model, which may be involved in regulating the JAK2/STAT3 signalling pathway. Cite this article: Bone Joint Res 2020;9(10):675–688


The Bone & Joint Journal
Vol. 102-B, Issue 2 | Pages 268 - 272
1 Feb 2020
Diarbakerli E Savvides P Wihlborg A Abbott A Bergström I Gerdhem P

Aims. Idiopathic scoliosis is the most common spinal deformity in adolescents and children. The aetiology of the disease remains unknown. Previous studies have shown a lower bone mineral density in individuals with idiopathic scoliosis, which may contribute to the causation. The aim of the present study was to compare bone health in adolescents with idiopathic scoliosis with controls. Methods. We included 78 adolescents with idiopathic scoliosis (57 female patients) at a mean age of 13.7 years (8.5 to 19.6) and 52 age- and sex-matched healthy controls (39 female patients) at a mean age of 13.8 years (9.1 to 17.6). Mean skeletal age, estimated according to the Tanner-Whitehouse 3 system (TW3), was 13.4 years (7.4 to 17.8) for those with idiopathic scoliosis, and 13.1 years (7.4 to 16.5) for the controls. Mean Cobb angle for those with idiopathic scoliosis was 29° (SD 11°). All individuals were scanned with dual energy x-ray absorptiometry (DXA) and peripheral quantitative CT (pQCT) of the left radius and tibia to assess bone density. Statistical analyses were performed with independent-samples t-test, the Mann-Whitney U test, and the chi-squared test. Results. Compared with controls, adolescents with idiopathic scoliosis had mean lower DXA values in the left femoral neck (0.94 g/cm. 2. (SD 0.14) vs 1.00 g/cm. 2. (SD 0.15)), left total hip (0.94 g/cm. 2. (SD 0.14) vs 1.01 g/cm. 2. (SD 0.17)), L1 to L4 (0.99 g/cm. 2. (SD 0.15) vs 1.06 g/cm. 2. (SD 0.17)) and distal radius (0.35 g/cm. 2. (SD 0.07) vs 0.39 g/cm. 2. (SD 0.08; all p ≤ 0.024), but not in the mid-radius (0.72 g/cm. 2. vs 0.74 g/cm. 2. ; p = 0.198, independent t-test) and total body less head (1,559 g (SD 380) vs 1,649 g (SD 492; p = 0.0.247, independent t-test). Compared with controls, adolescents with idiopathic scoliosis had lower trabecular volume bone mineral density (BMD) on pQCT in the distal radius (184.7 mg/cm. 3. (SD 40.0) vs 201.7 mg/cm. 3. (SD 46.8); p = 0.029), but not in other parts of the radius or the tibia (p ≥ 0.062, Mann-Whitney U test). Conclusion. In the present study, idiopathic scoliosis patients seemed to have lower BMD at central skeletal sites and less evident differences at peripheral skeletal sites when compared with controls. Cite this article: Bone Joint J 2020;102-B(2):268–272


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_12 | Pages 73 - 73
23 Jun 2023
Sheth N Bostrom M Winzenrieth R Humbert L Pearman L Caminis J Wang Y Boxberger J Krohn K
Full Access

To evaluate the effects of 6 and 18 months of abaloparatide (ABL) compared with placebo (PBO) on bone mineral density (BMD) in the acetabular regions of postmenopausal women with osteoporosis (OP). Acetabular bone loss, as may occur in OP, increases risk of acetabular fragility fractures. a. In total hip arthroplasty (THA), low acetabular BMD adversely affects primary stability, osseointegration, and migration of acetabular cups. c. ABL is an osteoanabolic agent for the treatment of men and postmenopausal women with OP at high risk for fracture. Effects of ABL on acetabular BMD are unknown. Hip DXA scans were obtained at baseline, 6, and 18 months from a random subgroup of postmenopausal women (aged 49–86 y) from the phase 3 ACTIVE trial randomized to either ABL 80 µg/d or PBO (n=250/group). Anatomical landmarks were identified in each DXA scan to virtually place a hemispherical shell model of an acetabular cup and define regions of interest corresponding to DeLee & Charnley zones 1 (R1), 2 (R2), and 3 (R3). BMD changes compared to baseline were calculated for each zone. Statistical P values were based on a repeated mixed measures model. BMD in all zones were similar at baseline in the ABL and PBO groups. BMD significantly increased in the ABL group at 6 and 18 months compared with PBO (all P<0.0001 vs PBO). BMD in the PBO group was relatively stable over time. ABL treatment resulted in rapid and progressive increases in BMD of all 3 acetabular zones. Increasing acetabular BMD has the potential to improve acetabular strength, which may reduce risk of acetabular fragility fractures. In bone health optimization prior to THA, increased acetabular BMD via ABL may provide better primary stability and longevity of acetabular cups in postmenopausal women with OP


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_8 | Pages 49 - 49
11 Apr 2023
Speirs A Melkus G Rakhra K Beaule P
Full Access

Femoroacetabular impingement (FAI) results from a morphological deformity of the hip and is associated with osteoarthritis (OA). Increased bone mineral density (BMD) is observed in the antero-superior acetabulum rim where impingement occurs. It is hypothesized that the repeated abnormal contact leads to damage of the cartilage layer, but could also cause a bone remodelling response according to Wolff's Law. Thus the goal of this study was to assess the relationship between bone metabolic activity measured by PET and BMD measured in CT scans. Five participants with asymptomatic cam deformity, three patients with uni-lateral symptomatic cam FAI and three healthy controls were scanned in a 3T PET-MRI scanner following injection with [18F]NaF. Bone remodelling activity was quantified with Standard Uptake Values (SUVs). SUVmax was analyzed in the antero-superior acetabular rim, femoral head and head-neck junction. In these same regions, BMD was calculated from CT scans using the calibration phantom included in the scan. The relationship between SUVmax and BMD from corresponding regions was assessed using the coefficient of determination (R. 2. ) from linear regression. High bone activity was seen in the cam deformity and acetabular rim. SUVmax was negatively correlated with BMD in the antero-superior region of the acetabulum (R. 2. =0.30, p=0.08). SUVmax was positively correlated with BMD in the antero-superior head-neck junction of the femur (R. 2. =0.359, p=0.067). Correlations were weak in other regions. Elevated bone turnover was seen in patients with a cam deformity but the relationship to BMD was moderate. This study demonstrates a pathomechanism of hip degeneration associated with FAI deformities, consistent with Wolff's law and the proposed mechanical cause of hip degeneration in FAI. [18F]-NaF PET SUV may be a biomarker of degeneration, especially in early stages of degeneration, when joint preservation surgery is likely to be the most successful


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_12 | Pages 14 - 14
23 Jun 2023
Hooper G Thompson D Frampton C Lash N Sharr J Fulkner D Gilchrist N
Full Access

Femoral stem design affects periprosthetic bone mineral density (BMD), which may impact long term survival of cementless implants in total hip arthroplasty (THA). The aim of this study was to examine proximal femoral BMD in three morphologically different uncemented femoral stems designs to investigate whether one particular design resulted in improved preservation of BMD. 119 patients were randomized to receive either a proximally coated dual taper wedge stem, a proximally coated anatomic stem or a fully coated collarless triple tapered stem. Dual energy x-ray absorptiometry scans (Lunar iDXA, GE Healthcare, Madison, WI) assessed BMD across the seven Gruen zones pre-operatively, and post-operatively at 6-weeks, 1-year, and 2-years comparing the unoperated contralateral femur as a control. BMD increased in zones one (2.5%), two (17.1%), three (13.0%), five (10%) and six (17.9%) for all stems. Greater preservation of BMD was measured on the lateral cortex (zone 2) for both the dual taper wedge and anatomic stems (p = 0.019). The dual taper wedge stem also demonstrated preservation of BMD in the medial calcar (zone 7) whilst the anatomic and triple taper stem declined in this region, however this was not statistically significant (p = 0.059). BMD decreased on average by 2.1% in the mid-diaphysis region, distal to the stem tip (zone 4) for all implants. All stems performed equivalently at final follow-up in all patient reported outcome measures. Implant design was shown to impact BMD changes. All stems preserved bone at the metaphyseal level in early follow-up, which theoretically indicates favorable implant fixation. There was no significant stress shielding observed, however longer follow-up is required to elucidate the impact of this finding on implant survivorship


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_7 | Pages 41 - 41
4 Apr 2023
Benca E Zderic I van Knegsel K Caspar J Hirtler L Fuchssteiner C Strassl A Gueorguiev B Widhalm H Windhager R Varga P
Full Access

Odontoid fracture of the second cervical vertebra (C2) is the most common spinal fracture type in elderly patients. However, very little is known about the biomechanical fracture mechanisms, but could play a role in fracture prevention and treatment. This study aimed to investigate the biomechanical competence and fracture characteristics of the odontoid process. A total of 42 human C2 specimens (14 female and 28 male, 71.5 ± 6.5 years) were scanned via quantitative computed tomography, divided in 6 groups (n = 7) and subjected to combined quasi-static loading at a rate of 0.1 mm/s until fracturing at inclinations of −15°, 0° and 15° in sagittal plane, and −50° and 0° in transverse plane. Bone mineral density (BMD), specimen height, fusion state of the ossification centers, stiffness, yield load, ultimate load, and fracture type according to Anderson and d'Alonzo were assessed. While the lowest values for stiffness, yield, and ultimate load were observed at load inclination of 15° in sagittal plane, no statistically significant differences could be observed among the six groups (p = 0.235, p = 0.646, and p = 0.505, respectively). Evaluating specimens with only clearly distinguishable fusion of the ossification centers (n = 26) reveled even less differences among the groups for all mechanical parameters. BMD was positively correlated with yield load (R² = 0.350, p < 0.001), and ultimate load (R² = 0.955, p < 0.001), but not with stiffness (p = 0.070). Type III was the most common fracture type (23.5%). These biomechanical outcomes indicate that load direction plays a subordinate role in traumatic fractures of the odontoid process in contrast to BMD which is a strong determinant of stiffness and strength. Thus, odontoid fractures appear to result from an interaction between load magnitude and bone quality


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_2 | Pages 77 - 77
10 Feb 2023
Hooper G Thompson D Lash N Sharr J Faulkner D Frampton C Gilchrist N
Full Access

Femoral stem design affects periprosthetic bone mineral density (BMD), which may impact long term survival of cementless implants in total hip arthroplasty (THA). The aim of this study was to examine proximal femoral BMD in three morphologically different uncemented femoral stems designs to investigate whether one particular design resulted in improved preservation of BMDMethods: 119 patients were randomised to receive either a proximally coated dual taper wedge stem, a proximally coated anatomic stem or a fully coated collarless triple tapered stem. All surgeries were performed via the posterior approach with mobilization on the day of surgery. Dual energy x-ray absorptiometry scans (Lunar iDXA, GE Healthcare, Madison, WI) assessed BMD across the seven Gruen zones pre-operatively, and post-operatively at 6-weeks, 1-year, and 2-years and compared to the unoperated contralateral femur as a control. Patient reported outcome measures of pain, function and health were also included at these corresponding follow-ups. BMD increased in zones one (2.5%), two (17.1%), three (13.0%), five (10%) and six (17.9%) for all stems. Greater preservation of BMD was measured on the lateral cortex (zone 2) for both the dual taper wedge and anatomic stems (p = 0.019). The dual taper wedge stem also demonstrated preservation of BMD in the medial calcar (zone 7) whilst the anatomic and triple taper stem declined in this region, however this was not statistically significant (p = 0.059). BMD decreased on average by 2.1% inthe mid-diaphysis region, distal to the stem tip (zone 4) for all implants. All stems performed equivalently at final follow-up in all patient reported outcome measures. This study demonstrated maintenance of femoral BMD in three different cementless femoral stem designs, with all achieving excellent improvements in patient reported outcomes. There was no significant stress shielding observed, however longer follow-up is required to elucidate the impact of this finding on implant survivorship


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_7 | Pages 53 - 53
4 Apr 2023
Hipps D Dobson P Warren C Russell O Turnbull D Deehan D Lawless C
Full Access

We have developed a novel technique to analyse bone, using imaging mass cytometry (IMC) without the constraints of using immunofluorescent histochemistry. IMC can measure the expression of over 40 proteins simultaneously, without autofluorescence. We analysed mitochondrial respiratory chain (RC) protein deficiencies in human bone which are thought to contribute to osteoporosis with increasing age. Osteoporosis is characterised by reduced bone mineral density (BMD) and fragility fractures. Humans accumulate mitochondrial mutations and RC deficiency with age and this has been linked to the changing phenotype in advancing age and age-related disease. Mitochondrial mutations are detectable from the age of 30 onwards, coincidently the age BMD begins to decline. Mitochondria contain their own genome which accumulates somatic variants at around 10 times the rate of nuclear DNA. Once these mutations exceed a threshold, RC deficiency and cellular dysfunction occur. The PolgD257A/D257A mouse model expresses a proof-reading deficient version of PolgA, a mtDNA polymerase. These mice accumulate mutations 3-5 times higher than wild-type mice showing enhanced levels of age-related osteoporosis and RC deficiency in osteoblasts. Bone samples were analysed from young and old patients, developing a protocol and analysis framework for IMC in bone tissue sections to analyse osteoblasts in-situ for RC deficiency. Samples from the femoral neck of 10 older healthy volunteers aged 40 – 85 were compared with samples from young patients aged 1-19. We have identified RC complex I defect in osteoblasts from 6 of the older volunteers, complex II defects in 2 of the older volunteers, complex IV defect in just 1 older volunteer, and complex V defect in 4 of the older volunteers. These observations are consistent with the PolgD257A/D257A mouse-model and suggest that RC deficiency, due to age-related pathogenic mitochondrial DNA mutations, may play a significant role in the pathogenesis of human age-related osteoporosis


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_7 | Pages 106 - 106
4 Apr 2023
Ding Y Luo W Chen Z Guo P Lei B Zhang Q Chen Z Fu Y Li C Ma T Liu J
Full Access

Quantitative ultrasound (QUS) is a promising tool to estimate bone structure characteristics and predict fragile fracture. The aim of this pilot cross-sectional study was to evaluate the performance of a multi-channel residual network (MResNet) based on ultrasonic radiofrequency (RF) signal to discriminate fragile fractures retrospectively in postmenopausal women. Methods. RF signal and speed of sound (SOS) were obtained using an axial transmission QUS at one‐third distal radius for 246 postmenopausal women. Based on the involved RF signal, we conducted a MResNet, which combines multi-channel training with original ResNet, to classify the high risk of fragility fractures patients from all subjects. The bone mineral density (BMD) at lumber, hip and femoral neck acquired with DXA was recorded on the same day. The fracture history of all subjects in adulthood were collected. To assess the ability of the different methods in the discrimination of fragile fracture, the odds ratios (OR) calculated using binomial logistic regression analysis and the area under the receiver operator characteristic curves (AUC) were analyzed. Results. Among the 246 postmenopausal women, 170 belonged to the non-fracture group, 50 to the vertebral group, and 26 to the non-vertebral fracture group. MResNet was discriminant for all fragile fractures (OR = 2.64; AUC = 0.74), for Vertebral fracture (OR = 3.02; AUC = 0.77), for non-vertebral fracture (OR = 2.01; AUC = 0.69). MResNet showed comparable performance to that of BMD of hip and lumbar with all types of fractures, and significantly better performance than SOS all types of fractures. Conclusions. the MResNet model based on the ultrasonic RF signal can significantly improve the ability of QUS device to recognize previous fragile fractures. Moreover, the performance of the proposed model modified by age, weight, and height is further optimized. These results open perspectives to evaluate the risk of fragile fracture applying a deep learning model to analyze ultrasonic RF signal


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_1 | Pages 26 - 26
2 Jan 2024
Jacob A Heumann M Zderic I Varga P Caspar J Lauterborn S Haschtmann D Fekete T Gueorguiev B Loibl M
Full Access

Stand-alone anterior lumbar interbody fusion (ALIF) provides the opportunity to avoid supplemental posterior fixation. This may reduce morbidity and complication rate, which is of special interest in patients with reduced bone mineral density (BMD). This study aims to assess immediate biomechanical stability and radiographic outcome of a stand-alone ALIF device with integrated screws in specimens of low BMD. Eight human cadaveric spines (L4-sacrum) were instrumented with SynFix-LR™ (DePuy Synthes) at L5/S1. Quantitative computed tomography was used to measure BMD of L5 in AMIRA. Threshold values proposed by the American Society of Radiology 80 and 120 mg CaHa/mL were used to differentiate between Osteoporosis, Osteopenia, and normal BMD. Segmental lordosis, anterior and posterior disc height were analysed on pre- and postoperative radiographs (Fig 1). Specimens were tested intact and following instrumentation using a flexibility protocol consisting of three loading cycles to ±7.5 Nm in flexion-extension, lateral bending, and axial rotation. The ranges of motion (ROM) of the index level were assessed using an optoelectronic system. BMD ranged 58–181mg CaHA/mL. Comparison of pre- and postoperative radiographs revealed significant increase of L5/S1 segmental lordosis (mean 14.6°, SD 5.1, p < 0.001) and anterior disc height (mean 5.8mm, SD 1.8, p < 0.001), but not posterior disc height. ROM of 6 specimens was reduced compared to the intact state. Two specimens showed destructive failure in extension. Mean decrease was most distinct in axial rotation up to 83% followed by flexion-extension. ALIF device with integrated screws at L5/S1 significantly increases segmental lordosis and anterior disc height without correlation to BMD. Primary stability in the immediate postoperative situation is mostly warranted in axial rotation. The risk of failure might be increased in extension for some patients with reduced lumbar BMD, therefore additional posterior stabilization could be considered. For any figures or tables, please contact the authors directly


Bone & Joint Research
Vol. 6, Issue 10 | Pages 584 - 589
1 Oct 2017
den Teuling J Pauwels B Janssen L Wyers C Janzing HMJ van den Bergh J Morrenhof JW

Objectives. The goal of this study is to investigate the relation between indicators of osteoporosis (i.e., bone mineral density (BMD), and Cortical Index (CI)) and the complexity of a fracture of the proximal humerus as a result of a low-energy trauma. Methods. A retrospective chart review of 168 patients (mean age 67.2 years, range 51 to 88.7) with a fracture of the proximal humerus between 2007 and 2011, whose BMD was assessed at the Fracture Liaison Service with Dual Energy X-ray Absorptiometry (DXA) measurements of the hip, femoral neck (FN) and/or lumbar spine (LS), and whose CI and complexity of fracture were assessed on plain anteroposterior radiographs of the proximal humerus. Results. No significant differences were found between simple and complex fractures of the proximal humerus in the BMD of the hip, FN or LS (all p > 0.3) or in the CI (p = 0.14). Only the body mass index was significantly higher in patients with a complex fracture compared with those with a simple fracture (26.9 vs 25.2; p = 0.05). Conclusion. There was no difference in BMD of the hip, FN, LS or CI of the proximal humerus in simple compared with complex fractures of the proximal humerus after a low-energy trauma. Factors other than the BMD and CI, for example body mass index, may play a more important role in the complexity of this fracture. Cite this article: J.W.A.M. den Teuling, B.S. Pauwels, L. Janssen, C.E. Wyers, H. M. J. Janzing, J.P.W. van den Bergh, J. W. Morrenhof. The Influence of bone mineral density and cortical index on the complexity of fractures of the proximal humerus. Bone Joint Res 2017;6:584–589. DOI: 10.1302/2046-3758.610.BJR-2017-0080


Bone & Joint Research
Vol. 5, Issue 9 | Pages 362 - 369
1 Sep 2016
Oba M Inaba Y Kobayashi N Ike H Tezuka T Saito T

Objectives. In total hip arthroplasty (THA), the cementless, tapered-wedge stem design contributes to achieving initial stability and providing optimal load transfer in the proximal femur. However, loading conditions on the femur following THA are also influenced by femoral structure. Therefore, we determined the effects of tapered-wedge stems on the load distribution of the femur using subject-specific finite element models of femurs with various canal shapes. Patients and Methods. We studied 20 femurs, including seven champagne flute-type femurs, five stovepipe-type femurs, and eight intermediate-type femurs, in patients who had undergone cementless THA using the Accolade TMZF stem at our institution. Subject–specific finite element (FE) models of pre- and post-operative femurs with stems were constructed and used to perform FE analyses (FEAs) to simulate single-leg stance. FEA predictions were compared with changes in bone mineral density (BMD) measured for each patient during the first post-operative year. Results. Stovepipe models implanted with large-size stems had significantly lower equivalent stress on the proximal-medial area of the femur compared with champagne-flute and intermediate models, with a significant loss of BMD in the corresponding area at one year post-operatively. Conclusions. The stovepipe femurs required a large-size stem to obtain an optimal fit of the stem. The FEA result and post-operative BMD change of the femur suggest that the combination of a large-size Accolade TMZF stem and stovepipe femur may be associated with proximal stress shielding. Cite this article: M. Oba, Y. Inaba, N. Kobayashi, H. Ike, T. Tezuka, T. Saito. Effect of femoral canal shape on mechanical stress distribution and adaptive bone remodelling around a cementless tapered-wedge stem. Bone Joint Res 2016;5:362–369. DOI: 10.1302/2046-3758.59.2000525


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_7 | Pages 147 - 147
4 Apr 2023
Tohidnezhad M Kubo Y Gonzalez J Weiler M Pahlavani H Szymanski K Mirazaali M Pufe T Jahr H
Full Access

Nuclear factor erythroid 2–related factor 2 (Nrf2) is a crucial transcription factor to maintain cellular redox homeostasis, but is also affecting bone metabolism. As the association between Nrf2 and osteoporosis in elderly females is not fully elucidated, our aim was to shed light on the potential contribution of Nrf2 to the development of age-dependent osteoporosis using a mouse model. Female wild-type (WT, n=18) and Nrf2-knockout (KO, n=12) mice were sacrificed at different ages (12 weeks=young mature adult, and 90 weeks=old), morphological cortical and trabecular properties of femoral bone analyzed by micro-computed tomography (µCT), and compared to histochemistry. Mechanical properties were derived from quasi-static compression tests and digital image correlation (DIC) used to analyze full-field strain distribution. Bone resorbing cells and aromatase expression by osteocytes were evaluated immunohistochemically and empty osteocyte lacunae counted in cortical bone. Wilcoxon rank sum test was used for data comparison and differences considered statistically significant at p<0.05. When compared to old WT mice, old Nrf2-KO mice revealed a significantly reduced trabecular bone mineral density (BMD), cortical thickness (Ct.Th), cortical area (Ct.Ar), and cortical bone fraction (Ct.Ar/Tt.Ar). Surprisingly, these parameters were not different in skeletally mature young adult mice. Metaphyseal trabeculae were thin but present in all old WT mice, while no trabecular bone was detectable in 60% of old KO mice. Occurrence of empty osteocyte lacunae did not differ between both groups, but a significantly higher number of osteoclast-like cells and fewer aromatase-positive osteocytes were found in old KO mice. Furthermore, female Nrf2-KO mice showed an age-dependently reduced fracture resilience when compared to age-matched WT mice. Our results confirmed lower bone quantity and quality as well as an increased number of bone resorbing cells in old female Nrf2-KO mice. Additionally, aromatase expression in osteocytes of old Nrf2-KO mice was compromised, which may indicate a chronic lack of estrogen in bones of old Nrf2-deficient mice. Thus, chronic Nrf2 loss seems to contribute to age-dependent progression of female osteoporosis


Bone & Joint Research
Vol. 7, Issue 11 | Pages 601 - 608
1 Nov 2018
Hsu W Hsu W Hung J Shen W Hsu RW

Objectives. Osteoporosis is a metabolic disease resulting in progressive loss of bone mass as measured by bone mineral density (BMD). Physical exercise has a positive effect on increasing or maintaining BMD in postmenopausal women. The contribution of exercise to the regulation of osteogenesis in osteoblasts remains unclear. We therefore investigated the effect of exercise on osteoblasts in ovariectomized mice. Methods. We compared the activity of differentially expressed genes of osteoblasts in ovariectomized mice that undertook exercise (OVX+T) with those that did not (OVX), using microarray and bioinformatics. Results. Many inflammatory pathways were significantly downregulated in the osteoblasts after exercise. Meanwhile, IBSP and SLc13A5 gene expressions were upregulated in the OVX+T group. Furthermore, in in vitro assay, IBSP and SLc13A5 mRNAs were also upregulated during the osteogenic differentiation of MC3T3-E1 and 7F2 cells. Conclusion. These findings suggest that exercise may not only reduce the inflammatory environment in ovariectomized mice, indirectly suppressing the overactivated osteoclasts, but may also directly activate osteogenesis-related genes in osteoblasts. Exercise may thus prevent the bone loss caused by oestrogen deficiency through mediating the imbalance between the bone resorptive activity of osteoclasts and the bone formation activity of osteoblasts. Cite this article: W-B. Hsu, W-H. Hsu, J-S. Hung, W-J. Shen, R. W-W. Hsu. Transcriptome analysis of osteoblasts in an ovariectomized mouse model in response to physical exercise. Bone Joint Res 2018;7:601–608. DOI: 10.1302/2046-3758.711.BJR-2018-0075.R2


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XLIII | Pages 52 - 52
1 Sep 2012
Al-Maiyah M Rawlings D Chuter G Ramaskandhan J Siddique M
Full Access

Introduction. There is no published series described change in bone mineral density (BMD) after ankle replacement. We present the results of a prospective study examining the effect of total ankle replacement (TAR) upon local bone mineral density (BMD). Aim. To design a method and assess the effect of TAR loading on local ankle bones, by analysing the BMD of different area around ankle before and after Mobility TAR. Methods. 23 patients undergoing Mobility ankle arthroplasty for osteoarthritis had preoperative bone densitometry scans of the ankle, repeated at 1 and 2 years after surgery. BMD of 2 cm. 2. areas around ankle were measured. Pre- and postoperative data were compared. Results: Mean BMD within the lateral malleolus decreased significantly from 0.5g/cm. 2. to 0.42g/cm. 2. (17%, P > 0.01), at 1 & 2 years postoperatively. Mean BMD within medial malleolus decreased slightly from 0.67g/cm. 2. to 0.64 g/cm. 2. at the same period. However BMD at medial side metaphysic of tibia increased by 7%. There was little increase in BMD in tibia just proximal to implant and at talus. Discussion and Conclusion. Absence of stress shielding around distal tibia, just proximal to tibial component and talus indicates that ankle replacements implanted within the accepted limits for implant alignment, load distal tibia and talus. However, there was stress shielding over the lateral malleolus resulting in decreased BMD in lateral malleolus. Increase BMD at tibial metaphysis, proximal to medial malleolus indicates an increase in mechanical stress which may explain occasional postoperative stress fracture of medial malleolus or medial side ankle pain


Bone & Joint Research
Vol. 6, Issue 10 | Pages 572 - 576
1 Oct 2017
Wang W Huang S Hou W Liu Y Fan Q He A Wen Y Hao J Guo X Zhang F

Objectives. Several genome-wide association studies (GWAS) of bone mineral density (BMD) have successfully identified multiple susceptibility genes, yet isolated susceptibility genes are often difficult to interpret biologically. The aim of this study was to unravel the genetic background of BMD at pathway level, by integrating BMD GWAS data with genome-wide expression quantitative trait loci (eQTLs) and methylation quantitative trait loci (meQTLs) data. Method. We employed the GWAS datasets of BMD from the Genetic Factors for Osteoporosis Consortium (GEFOS), analysing patients’ BMD. The areas studied included 32 735 femoral necks, 28 498 lumbar spines, and 8143 forearms. Genome-wide eQTLs (containing 923 021 eQTLs) and meQTLs (containing 683 152 unique methylation sites with local meQTLs) data sets were collected from recently published studies. Gene scores were first calculated by summary data-based Mendelian randomisation (SMR) software and meQTL-aligned GWAS results. Gene set enrichment analysis (GSEA) was then applied to identify BMD-associated gene sets with a predefined significance level of 0.05. Results. We identified multiple gene sets associated with BMD in one or more regions, including relevant known biological gene sets such as the Reactome Circadian Clock (GSEA p-value = 1.0 × 10. -4. for LS and 2.7 × 10. -2. for femoral necks BMD in eQTLs-based GSEA) and insulin-like growth factor receptor binding (GSEA p-value = 5.0 × 10. -4. for femoral necks and 2.6 × 10. -2. for lumbar spines BMD in meQTLs-based GSEA). Conclusion. Our results provided novel clues for subsequent functional analysis of bone metabolism, and illustrated the benefit of integrating eQTLs and meQTLs data into pathway association analysis for genetic studies of complex human diseases. Cite this article: W. Wang, S. Huang, W. Hou, Y. Liu, Q. Fan, A. He, Y. Wen, J. Hao, X. Guo, F. Zhang. Integrative analysis of GWAS, eQTLs and meQTLs data suggests that multiple gene sets are associated with bone mineral density. Bone Joint Res 2017;6:572–576


Bone & Joint Research
Vol. 3, Issue 11 | Pages 317 - 320
1 Nov 2014
Basso T Klaksvik J Foss OA

Objective. In ex vivo hip fracture studies femoral pairs are split to create two comparable test groups. When more than two groups are required, or if paired femurs cannot be obtained, group allocation according to bone mineral density (BMD) is sometimes performed. In this statistical experiment we explore how this affects experimental results and sample size considerations. Methods. In a hip fracture experiment, nine pairs of human cadaver femurs were tested in a paired study design. The femurs were then re-matched according to BMD, creating two new test groups. Intra-pair variance and paired correlations in fixation stability were calculated. A hypothetical power analysis was then performed to explore the required sample size for the two types of group allocation. . Results. The standard deviation (. sd. ) of the mean paired difference in fixation stability increased from 2 mm in donor pairs to 5 mm in BMD-matched pairs. Intra-pair correlation was 0.953 (Pearson’s r) in donor pairs and non-significant at -0.134 (Pearson’s r) in BMD-matched pairs. Required sample size to achieve a statistical power of 0.8 increased from ten pairs using donor pairs to 54 pairs using BMD-matched pairs. Conclusion. BMD cannot be used to create comparable test groups unless sample size is increased substantially and paired statistics are no longer valid. Cite this article: Bone Joint Res 2014;3:317–20


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_2 | Pages 111 - 111
1 Jan 2017
Menichetti A Gargiulo P Gislason M Edmunds K Hermannsson T Jonsson H Esposito L Bifulco P Cesarelli M Fraldi M Cristofolini L
Full Access

Total Hip Replacement (THR) is one of the most successful operations in all of medicine, however surgeons just rely on their experience and expertise when choosing between cemented or cementless stem, without having any quantitative guidelines. The aim of this project is to provide clinicians with some tools to support in their decision making. A novel method based on bone mineral density (BMD) measurements and assessments was developed 1) to estimate the periprosthetic fracture risk (FR) while press-fitting cementless stem; 2) to evaluate post-operative bone remodeling in terms of BMD changes after primary THR. Data for 5 out of over 70 patients (already involved in a previous study. 1. ) that underwent primary THA in Iceland were selected for developing novel methods to assess intra-operative FR and bone mineral density (BMD) changes after the operation. For each patient three CT images were acquired (Philips Brilliance 64 Spiral-CT, 120 kVp, slice thickness: 1 mm, slice increment: 0.5 mm): pre-op, 24 hours and 1 year post-operative. Pre-op CT scan was used to create 3D finite element model (Materialise Mimics) of the proximal femur. The material properties were assigned based on Hounsfield Units. Different strategies were analyzed for simulating the press-fitting operation, developing what has already been done in prior study. 1. In the finite element simulation (Ansys Workbench), a pressure (related to the implant hammering force of 9.25 kN. 2. ) was applied around the femur's hollow for the stem and the distribution of maximum principal elastic strain over the bone was calculated. Assuming a critical failure value. 3. of 7300 με, the percentage of fractured elements was calculated (i.e. FR). Post 24 hours and Post 1 year CT images were co-registrated and compared (Materialise Mimics) in order to assess BMD changes. Successively, volumes of bone lost and bone gained were calculated and represented in a 3D model. Age and gender should not be taken as unique indicators to choose between implants typologies, since also three dimensional BMD distribution along with volume of cortical bone influence the risk of periprosthetic fractures. Highest FR values were experienced in the calcar-femorale zone and in similar location on the posterior side. BMD loss volume fractions after 1 year were usually higher than BMD gain ones. Consistently with prior studies. 4. , BMD loss was mainly concentrated around the proximal end (lesser trochanter area, outer bone). If present, BMD gain occurred at the distal end (below stem's tip) or proximally (lesser trochanter area, interface contact with the stem). The use of clinical data for BMD assessments serves as an important tool to develop a quantitative method which will support surgeons in their decisions, guiding them to the optimal implant for the patient. Knowing the risk of fracture if choosing a cementless stem and being aware of how the bone will remodel around the stem in one year's time can eventually lead to reduction in revisions and increased quality of life for the patient. Further work will target analysis of a larger cohort of patients and validate FE models


Bone & Joint Research
Vol. 8, Issue 6 | Pages 275 - 287
1 Jun 2019
Clement ND Bardgett M Merrie K Furtado S Bowman R Langton DJ Deehan DJ Holland J

Objectives. Our primary aim was to describe migration of the Exeter stem with a 32 mm head on highly crosslinked polyethylene and whether this is influenced by age. Our secondary aims were to assess functional outcome, satisfaction, activity, and bone mineral density (BMD) according to age. Patients and Methods. A prospective cohort study was conducted. Patients were recruited into three age groups: less than 65 years (n = 65), 65 to 74 years (n = 68), and 75 years and older (n = 67). There were 200 patients enrolled in the study, of whom 115 were female and 85 were male, with a mean age of 69.9 years (sd 9.5, 42 to 92). They were assessed preoperatively, and at three, 12 and, 24 months postoperatively. Stem migration was assessed using Einzel-Bild-Röntgen-Analyse (EBRA). Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC), Harris Hip Score (HHS), Hip Disability and Osteoarthritis Outcome Score (HOOS), EuroQol-5 domains questionnaire (EQ-5D), short form-36 questionnaire (SF-36,) and patient satisfaction were used to assess outcome. The Lower Extremity Activity Scale (LEAS), Timed Up and Go (TUG) test, and activPAL monitor (energy expelled, time lying/standing/walking and step count) were used to assess activity. The BMD was assessed in Gruen and Charnley zones. Results. Mean varus/valgus tilt was -0.77⁰ and axial subsidence was -1.20 mm. No significant difference was observed between age groups (p ⩾ 0.07). There was no difference according to age group for postoperative WOMAC (p ⩾ 0.11), HHS (p ⩾ 0.06), HOOS (p ⩾ 0.46), EQ-5D (p ⩾ 0.38), patient satisfaction (p ⩾ 0.05), or activPAL (p ⩾ 0.06). Patients 75 years and older had a worse SF-36 physical function (p = 0.01) and physical role (p = 0.03), LEAS score (p < 0.001), a shorter TUG (p = 0.01), and a lower BMD in Charnley zone 1 (p = 0.02). Conclusion. Exeter stem migration is within normal limits and is not influenced by age group. Functional outcome, patient satisfaction, activity level, and periprosthetic BMD are similar across all age groups. Cite this article: N. D. Clement, M. Bardgett, K. Merrie, S. Furtado, R. Bowman, D. J. Langton, D. J. Deehan, J. Holland. Cemented Exeter total hip arthroplasty with a 32 mm head on highly crosslinked polyethylene: Does age influence functional outcome, satisfaction, activity, stem migration, and periprosthetic bone mineral density? Bone Joint Res 2019;8:275–287. DOI: 10.1302/2046-3758.86.BJR-2018-0300.R1


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_13 | Pages 29 - 29
1 Nov 2021
Micheletti C Shah FA Grandfield K Palmquist A
Full Access

Introduction and Objective. Type 2 diabetes mellitus (T2DM), and the often concurrent obesity, causes metabolic changes that affect many organs and tissues, including bone. Despite a normal or even higher bone mineral density (BMD), T2DM has often been associated with a higher fracture risk, indicating a compromised bone quality. In this work, we use a novel congenic leptin receptor-deficient BioBreeding Diabetes Resistant rat (BBDR.cg.lepr.cp) to investigate the impact of T2DM and obesity on bone morphology and architecture at the microscale. Materials and Methods. Two different anatomical locations, i.e., femur and cranium, were studied combining micro-computed X-ray tomography (micro-CT) with scanning electron microscopy (SEM). Micro-CT data were examined using advanced image analysis tools in three-dimensions (3D). Results. Both parietal bones and femurs were smaller, i.e., thinner and shorter, respectively, in diabetic animals compared to healthy controls. Image analysis of the sagittal suture revealed a reduced suture width and length in diabetic animals, suggesting an altered bone apposition rate. Histomorphometry analysis from micro-CT data highlighted differences in microstructure of both trabecular and cortical femur between diabetic and healthy rats. In particular, bone volume fraction (BV/TV) was lower in the T2DM group, while trabecular spacing (Tb.Sp) was increased, overall indicating a higher porosity in diabetic trabecular bone. SEM revealed the presence of extended portions of hyper-mineralized cartilage in the distal femur of the diabetic animals. Conclusions. Micro-CT analyses, combined with SEM imaging, suggest that T2DM impacts bone growth and remodelling, in turn leading to differences in the structural organization at the microscale


Orthopaedic Proceedings
Vol. 86-B, Issue SUPP_III | Pages 324 - 324
1 Mar 2004
Rajesh M Manning P Neumann L Wallace W
Full Access

Introduction: The aim of this paper is to biomechanically evaluate its stabilisation properties of a new retrograde device used in the þxation of proximal humeral fractures and to assess the effect of Bone Mineral Density (BMD) on its intramedullary þxation. The device incorporates a trio wire at the proximal end instead of a conventional proximal locking screw relying on it for proximal humeral segment stability. Methods: Eight fresh frozen human humeri were harvested from post mortem specimens and evaluated for Bone Mineral Density (BMD). The long axis of the nail and the rotational axis of the humerus were perfectly aligned. A 2-mm perpendicular osteotomy (fracture), 3cm distal to the distal margin of the medial joint surface represented the most rotationally unstable proximal humeral fracture. The proximal end was loaded for torque at a rate of 10û/sec. All testing was halted at failure (10% drop in recorded load). Results: The mean torque hold at failure was 1.51 ± 0.56, median 1.4 Nm-1. The mean rotation observed at failure was 32.2û ± 21.43û, median 34.3û. No signiþcant relationship was identiþed between proximal humeral bone mineral density and Failure of torque hold with the use of this particular device. Conclusions: Biomechanical data from previous similar studies are based on highly variable testing conþgurations. True comparisons are difþcult to obtain. This study shows that the trio wires deform with minimal torque. The Nail is weak in torsional control when compared to other implants available for the treatment of proximal humeral fractures


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_16 | Pages 40 - 40
1 Dec 2021
Cheong VS Roberts B Kadirkamanathan V Dall'Ara E
Full Access

Abstract. Objectives. Current therapies for osteoporosis are limited to generalised antiresorptive or anabolic interventions, which do not target specific regions to improve skeletal health. Moreover, the adaptive changes of separate and combined pharmacological and biomechanical treatments in the ovariectomised (OVX) mouse tibia has not been studied yet. Therefore, this study combines micro- computed tomography (micro-CT) imaging and computational modelling to evaluate the efficacies of treatments in reducing bone loss. Methodology. In vivo micro-CT (10.4µm/voxel) images of the right tibiae of N=18 female OVX C57BL/6 mice were acquired at weeks 14, 16, 18, 20 and 22 of age for 3 groups: mechanical loading (ML), parathyroid hormone (PTH) or combined therapies (PTHML). All mice received either injection of PTH (100μg/kg/day, 5days/week) or vehicle from week 18. The right tibiae were mechanically loaded in vivo at week 19 and 21 with a 12N peak load, 40 cycles/day and 3 days/week. Bone adaptation was quantified through spatial changes in bone mineral density (BMD) and strain distribution was obtained from micro-CT-based finite element models. Results. Densitometric parameters improved for all treatment between week 18–20 (10–21%), with the strongest benefits due to loading in the proximal regions (16–35%). At week 22, PTHML treatment induced 23–76% higher bone apposition in the proximal tibia than either monotherapy. Compared to the OVX control, all treatments reduced periosteal resorption at weeks 18–20 and 20–22 (20–87%). However, resorption in weeks 20–22 were 29–55% higher than weeks 18–20, increasing the strain in the proximal tibia. Synergistic effects of PTH and ML were observed on the periosteal surface of proximal tibia, but additive effects were seen predominately on the distal and lateral tibia. Conclusions. ML had a more dominant effect in improving bone health. PTH enhances bone's osteogenic response to ML additively and synergistically in a site- and time-dependent manner


The Bone & Joint Journal
Vol. 101-B, Issue 4 | Pages 365 - 371
1 Apr 2019
Nam D Salih R Nahhas CR Barrack RL Nunley RM

Aims. Modular dual mobility (DM) prostheses in which a cobalt-chromium liner is inserted into a titanium acetabular shell (vs a monoblock acetabular component) have the advantage of allowing supplementary screw fixation, but the potential for corrosion between the liner and acetabulum has raised concerns. While DM prostheses have shown improved stability in patients deemed ‘high-risk’ for dislocation undergoing total hip arthroplasty (THA), their performance in young, active patients has not been reported. This study’s purpose was to assess clinical outcomes, metal ion levels, and periprosthetic femoral bone mineral density (BMD) in young, active patients receiving a modular DM acetabulum and recently introduced titanium, proximally coated, tapered femoral stem design. Patients and Methods. This was a prospective study of patients between 18 and 65 years of age, with a body mass index (BMI) < 35 kg/m. 2. and University of California at Los Angeles (UCLA) activity score > 6, who received a modular cobalt-chromium acetabular liner, highly crosslinked polyethylene mobile bearing, and cementless titanium femoral stem for their primary THA. Patients with a history of renal disease and metal hardware elsewhere in the body were excluded. A total of 43 patients (30 male, 13 female; mean age 52.6 years (. sd. 6.5)) were enrolled. All patients had a minimum of two years’ clinical follow-up. Patient-reported outcome measures, whole blood metal ion levels (ug/l), and periprosthetic femoral BMD were measured at baseline, as well as at one and two years postoperatively. Power analysis indicated 40 patients necessary to demonstrate a five-fold increase in cobalt levels from baseline (alpha = 0.05, beta = 0.80). A mixed model with repeated measures was used for statistical analysis. Results. Mean Harris Hip Scores improved from 54.1 (. sd. 20.5) to 91.2 (. sd. 10.8) at two years postoperatively (p < 0.001). All patients had radiologically well-fixed components, no patients experienced any instability, and no patients required any further intervention. Mean cobalt levels increased from 0.065 ug/l (. sd. 0.03) preoperatively to 0.30 ug/l (. sd. 0.51) at one year postoperatively (p = 0.01) but decreased at two years postoperatively to 0.16 ug/l (. sd. 0.23; p = 0.2). Four patients (9.3%) had a cobalt level outside the reference range (0.03 ug/l to 0.29 ug/l) at two years postoperatively, with values from 0.32 ug/l to 0.94 ug/l. The mean femoral BMD ratio was maintained in Gruen zones 2 to 7 at both one and two years postoperatively using this stem design. At two years postoperatively, mean BMD in the medial calcar was 101.5% of the baseline value. Conclusion. Use of a modular DM prosthesis and cementless, tapered femoral stem has shown encouraging results in young, active patients undergoing primary THA. Elevation in mean cobalt levels and the presence of four patients outside the reference range at two years postoperatively demonstrates the necessity of continued surveillance in this cohort. Cite this article: Bone Joint J 2019;101-B:365–371


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 6 | Pages 794 - 798
1 Jun 2010
Minoda Y Ikebuchi M Kobayashi A Iwaki H Inori F Nakamura H

Bone mineral density (BMD) around the femoral component has been reported to decrease after total knee replacement (TKR) because of stress shielding. Our aim was to determine whether a cemented mobile-bearing component reduced the post-operative loss of BMD. In our study 28 knees receiving a cemented fixed-bearing TKR were matched with 28 receiving a cemented mobile-bearing TKR. They underwent dual-energy x-ray absorptiometry, pre-operatively and at three weeks and at three, six, 12, 18 and 24 months post-operatively. The patients were not taking medication to improve the BMD. The pre-operative differences in the BMD of the femoral neck, wrist, lumbar spine and knee in the two groups were not significant. The BMD of the femur decreased postoperatively in the fixed-bearing group, but not the mobile-bearing group. The difference in the post-operative change in the BMD in the two groups was statistically significant (p < 0.05) at 18 and 24 months. Our findings show that a cemented mobile-bearing TKR has a favourable effect on the BMD of the distal femur after TKR in the short term. Further study is required to determine the long-term effects


Orthopaedic Proceedings
Vol. 87-B, Issue SUPP_I | Pages 64 - 64
1 Mar 2005
Castoldi F Lollino N D’Amelio P Sattin F Delise M Girardo M Dettoni F Bignardi C Rossi R Isaia G
Full Access

Aims: evaluate the relationship between Singh index (SI), bone mineral density (BMD) examining bone mechanical properties from ex-vivo human femoral heads. Methods: we collected the femoral heads of 22 patients that underwent arthroplastic for fracture of femoral head under low energy trauma. 5 patients were male while 17 were female. In each patient a pelvis X-ray was performed to estimate Singh Index. From 2 to 3 bone cylinders of cancellous bone were obtained from each femoral head. 52 bone cylinders (7x10mm) were obtained. In each specimen densitometric scans were performed by means of a Hologic QDR 4500 X-ray densitometer, using a small animal software. The coefficient of variation (CV) was calculated by repositioning a sample for 5 scans by different operators. The data obtained were expressed as bone mineral content (BMC) and bone mineral density (BMD). Compression tests with a JJ Instruments T5K machine were conducted on 52 spongy bone cylinders. Each specimen was loaded in movement control; maximum failure load and Young modulus were recorded. Results The CV for the precision was 1.8% for BMC and 2.7% for BMD. There are no differences between males and females in age, BMC, BMD and Young modulus, while there is a significant difference in maximum load and SI. As regards SI values, there are significant differences among different categories of SI for age, sex, BMC, BMD, Young modulus and maximum failure load. Considering each sample position, namely 1, 2 or 3, there was no significant difference in densitometric parameters and in mechanical properties Statistical analyses of correlations by Pearson’s coefficient showed significant inverse correlations between age and mechanical bone properties (Young modulus and maximum failure load), while the correlations between BMC, BMD and biomechanical bone behaviour were strictly direct Linear regression model demonstrated only maximum load predictors are Young modulus and BMD. Conclusions The maximum failure load is lower in females than in males with similar BMD but lower SI for different SI categories there are significant differences both in biomechanical behaviour both in densitometric parameters.The age is inversely correlated with bone densitometric features and bone biomechanical behaviour, while bone density is directly correlated with bone strength and elastic modulus.The bone strength is predicted with 93% accuracy by Young modulus and BMD


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 2 | Pages 174 - 179
1 Feb 2007
Kim Y Yoon S Kim J

Our aim in this prospective study was to compare the bone mineral density (BMD) around cementless acetabular and femoral components which were identical in geometry and had the same alumina modular femoral head, but differed in regard to the material of the acetabular liners (alumina ceramic or polyethylene) in 50 patients (100 hips) who had undergone bilateral simultaneous primary total hip replacement. Dual energy X-ray absorptiometry scans of the pelvis and proximal femur were obtained at one week, at one year, and annually thereafter during the five-year period of the study. At the final follow-up, the mean BMD had increased significantly in each group in acetabular zone I of DeLee and Charnley (20% (15% to 26%), p = 0.003), but had decreased in acetabular zone II (24% (18% to 36%) in the alumina group and 25% (17% to 31%) in the polyethylene group, p = 0.001). There was an increase in the mean BMD in zone III of 2% (0.8% to 3.2%) in the alumina group and 1% (0.6% to 2.2%) in the polyethylene group (p = 0.315). There was a decrease in the mean BMD in the calcar region (femoral zone 7) of 15% (8% to 24%) in the alumina group and 14% (6% to 23%) in the polyethylene group (p < 0.001). The mean bone loss in femoral zone 1 of Gruen et al was 2% (1.1% to 3.1%) in the alumina group and 3% (1.3% to 4.3%) in the polyethylene group (p = 0.03), and in femoral zone 6, the mean bone loss was 15% (9% to 27%) in the alumina group and 14% (11% to 29%) in the polyethylene group compared with baseline values. There was an increase in the mean BMD on the final scans in femoral zones 2 (p = 0.04), 3 (p = 0.04), 4 (p = 0.12) and 5 (p = 0.049) in both groups. There was thus no significant difference in the bone remodelling of the acetabulum and femur five years after total hip replacement in those two groups where the only difference was in the acetabular liner


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_4 | Pages 106 - 106
1 Mar 2021
Torgutalp SS Babayeva N Kara OS Özkan Ö Güdemez G Korkusuz F
Full Access

Osteoporosis is a common disorder characterized by low bone mass and reduced bone quality that affects the bone strength negatively and leads to increased risk of fracture. Bone mineral density (BMD) has been the standard instrument for the diagnosis of osteoporosis and the determination of fracture risk. Despite the approximation of the bone mass, BMD does not provide information about the bone structure. Trabecular bone score (TBS), which provides an indirect evaluation of skeletal microarchitecture, is calculated from dual X-ray absorptiometry and a simple and noninvasive method that may contribute to the prediction of osteoporotic fractures in addition to the measure of bone density. The goal of this study was to determine the mean TBS values in healthy postmenopausal women and the overall association between TBS and demographic features, bone mineral density of the lumbar spine and femoral neck and bone mineral density to body mass index ratio (BMD/BMI) of the lumbar spine. Fifty-three postmenopausal healthy women participated. The bone mineral density of the lumbar spine and femoral neck were measured dual X-ray absorptiometry. Anteroposterior lumbar spine acquisitions were used to calculate TBS for L1-L4. Age, height, weight, BMI and the ratio of BMD to BMI, which was considered to be a simple tool for assessing fracture risk in especially obese individuals, were calculated. The relationship between TBS and other variables was examined using Spearman's rank correlation coefficients. Mean BMD of the lumbar spine and the femoral neck were 0.945 ± 0.133 and 0.785 ± 0.112 g/cm2, respectively (Table 1). Mean TBS was 1.354 ± 0.107. There was a significant positive moderate correlation between TBS and total lumbar BMD/BMI ratio (r=0.595, pTBS values of postmenopausal women were negatively correlated with age and BMI and positively with bone mineral density and BMD/BMI ratio. The ratio between lumbar BMD and BMI presented a stronger correlation with TBS than that of BMD with TBS. Because of the better correlation, the BMD/BMI ratio may be used as a simple tool for the assessment of the risk of fractures. Further investigation may be needed to evaluate the factors influencing exercise intervention on TBS on this population of patients


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_1 | Pages 9 - 9
1 Feb 2021
Soltanihafshejani N Bitter T Janssen D Verdonschot N
Full Access

Introduction. The fixation of press-fit orthopaedic devices depends on the mechanical properties of the bone that is in contact with the implants. During the press-fit implantation, bone is compacted and permanently deformed, finally resulting in the mechanical interlock between implant and bone. For the development and design of new devices, it is imperative to understand these non-linear interactions. One way to investigate primary fixation is by using computational models based on Finite Element (FE) analysis. However, for a successful simulation, a proper material model is necessary that accurately captures the non-linear response of the bone. In the current study, we combined experimental testing with FE modeling to establish a Crushable Foam model (CFM) to represent the non-linear bone biomechanics that influences implant fixation. Methods. Mechanical testing of human tibial trabecular bone was done under uniaxial and confined compression configurations. We examined 62 human trabecular bone samples taken from 8 different cadaveric tibiae to obtain all the required parameters defining the CFM, dependent on local bone mineral density (BMD). The derived constitutive rule was subsequently applied using an in-house subroutine to the FE models of the bone specimens, to compare the model predictions against the experimental results. Results. The crushable foam model provided an accurate simulation of the experimental compression test, and was able to replicate the ultimate compression strength measured in the experiments [Figure 1]. The CFM was able to simulate the post-failure behavior that was observed in the experimental specimens up to strain levels of 50% [Figure 2]. Also, the distribution of yield strains and permanent displacement was qualitatively very similar to the experimental deformation of the bone specimens [Figure 3]. Conclusion. The crushable foam model developed in the current study was able to accurately replicate the mechanical behavior of the human trabecular bone under compression loading beyond the yield point. This advanced bone model enables realistic simulations of the primary fixation of orthopaedic devices, allowing for the analysis of the influence of interference fit and frictional properties on implant stability. In addition, the model is suitable for failure analysis of reconstructions, such as the tibial collapse of total knee arthroplasty. For any figures or tables, please contact the authors directly


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 1 | Pages 93 - 97
1 Jan 2012
Lee JH Lee J Park JW Shin YH

In patients with osteoporosis there is always a strong possibility that pedicle screws will loosen. This makes it difficult to select the appropriate osteoporotic patient for a spinal fusion. The purpose of this study was to determine the correlation between bone mineral density (BMD) and the magnitude of torque required to insert a pedicle screw. To accomplish this, 181 patients with degenerative disease of the lumbar spine were studied prospectively. Each underwent dual-energy x-ray absorptiometry (DEXA) and intra-operative measurement of the torque required to insert each pedicle screw. The levels of torque generated in patients with osteoporosis and osteopenia were significantly lower than those achieved in normal patients. Positive correlations were observed between BMD and T-value at the instrumented lumbar vertebrae, mean BMD and mean T-value of the lumbar vertebrae, and mean BMD and mean T-value of the proximal femur. The predictive torque (Nm) generated during pedicle screw insertion was [-0.127 + 1.62 × (BMD at the corresponding lumbar vertebrae)], as measured by linear regression analysis. The positive correlation between BMD and the maximum torque required to insert a pedicle screw suggests that pre-operative assessment of BMD may be useful in determining the ultimate strength of fixation of a device, as well as the number of levels that need to be fixed with pedicle screws in patients who are suspected of having osteoporosis


The Bone & Joint Journal
Vol. 97-B, Issue 3 | Pages 337 - 345
1 Mar 2015
Jaroma AVJ Soininvaara TA Kröger H

Total knee arthroplasty (TKA) is known to lead to a reduction in periprosthetic bone mineral density (BMD). In theory, this may lead to migration, instability and aseptic loosening of the prosthetic components. Bisphosphonates inhibit bone resorption and may reduce this loss in BMD. We hypothesised that treatment with bisphosphonates and calcium would lead to improved BMD and clinical outcomes compared with treatment with calcium supplementation alone following TKA. A total of 26 patients, (nine male and 17 female, mean age 67 years) were prospectively randomised into two study groups: alendronate and calcium (bisphosphonate group, n = 14) or calcium only (control group, n = 12). Dual energy X-ray absorptiometry (DEXA) measurements were performed post-operatively, and at three months, six months, one, two, four, and seven years post-operatively. . Mean femoral metaphyseal BMD was significantly higher in the bisphosphonate group compared with controls, up to four years following surgery in some areas of the femur (p = 0.045). BMD was observed to increase in the lateral tibial metaphysis in the bisphosphonate group until seven years (p = 0.002), and was significantly higher than that observed in the control group throughout (p = 0.024). There were no significant differences between the groups in the central femoral metaphyseal, tibial medial metaphyseal or diaphyseal regions of interest (ROI) of either the femur or tibia. Bisphosphonate treatment after TKA may be of benefit for patients with poor bone quality. However, further studies with a larger number of patients are necessary to assess whether this is clinically beneficial. Cite this article: Bone Joint J 2015;97-B:337–45


Bone & Joint Research
Vol. 5, Issue 11 | Pages 538 - 543
1 Nov 2016
Weeks BK Hirsch R Nogueira RC Beck BR

Objectives. The aim of the current study was to assess whether calcaneal broadband ultrasound attenuation (BUA) can predict whole body and regional dual-energy x-ray absorptiometry (DXA)-derived bone mass in healthy, Australian children and adolescents at different stages of maturity. Methods. A total of 389 boys and girls across a wide age range (four to 18 years) volunteered to participate. The estimated age of peak height velocity (APHV) was used to classify children into pre-, peri-, and post-APHV groups. BUA was measured at the non-dominant heel with quantitative ultrasonometry (QUS) (Lunar Achilles Insight, GE), while bone mineral density (BMD) and bone mineral content (BMC) were examined at the femoral neck, lumbar spine and whole body (DXA, XR-800, Norland). Associations between BUA and DXA-derived measures were examined with Pearson correlations and linear regression. Participants were additionally ranked in quartiles for QUS and DXA measures in order to determine agreement in rankings. Results. For the whole sample, BUA predicted 29% of the study population variance in whole body BMC and BMD, 23% to 24% of the study population variance in lumbar spine BMC and BMD, and 21% to 24% of the variance in femoral neck BMC and BMD (p < 0.001). BUA predictions were strongest for the most mature participants (pre-APHV R. 2. = 0.03 to 0.19; peri-APHV R. 2. = 0.05 to 0.17; post-APHV R. 2. = 0.18 to 0.28) and marginally stronger for girls (R. 2. = 0.25-0.32, p < 0.001) than for boys (R. 2. = 0.21-0.27, p < 0.001). Agreement in quartile rankings between QUS and DXA measures of bone mass was generally poor (27.3% to 38.2%). Conclusion. Calcaneal BUA has a weak to moderate relationship with DXA measurements of bone mass in children, and has a tendency to misclassify children on the basis of quartile rankings. Cite this article: B. K. Weeks, R. Hirsch, R. C. Nogueira, B. R. Beck. Is calcaneal broadband ultrasound attenuation a valid index of dual-energy x-ray absorptiometry-derived bone mass in children? Bone Joint Res 2016;5:538–543. DOI: 10.1302/2046-3758.511.BJR-2016-0116.R1


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 4 | Pages 455 - 459
1 Apr 2006
Shetty NR Hamer AJ Kerry RM Stockley I Eastell R Wilkinson JM

The aims of this study were to examine the repeatability of measurements of bone mineral density (BMD) around a cemented polyethylene Charnley acetabular component using dual-energy x-ray absorptiometry and to determine the longitudinal pattern of change in BMD during the first 24 months after surgery. The precision of measurements of BMD in 19 subjects ranged from 7.7% to 10.8% between regions, using a four-region-of-interest model. A longitudinal study of 27 patients demonstrated a transient decrease in net pelvic BMD during the first 12 months, which recovered to baseline at 24 months. The BMD in the region medial to the dome of the component reduced by between 7% and 10% during the first three months, but recovered to approximately baseline values by two years. Changes in BMD in the pelvis around cemented acetabular components may be measured using dual-energy x-ray absorptiometry. Bone loss after insertion of a cemented Charnley acetabular component is small, transient and occurs mainly at the medial wall of the acetabulum. After two years, bone mass returns to baseline values, with a pattern suggesting a uniform transmission of load to the acetabulum


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_13 | Pages 68 - 68
1 Nov 2021
Monahan G Schiavi J Vaughan T
Full Access

Introduction and Objective. Individuals with type 2 diabetes (T2D) have a 3-fold increased risk of bone fracture compared to non-diabetics, with the majority of fractures occurring in the hip, vertebrae and wrists. However, unlike osteoporosis, in T2D, increased bone fragility is generally not accompanied by a reduction in bone mineral density (BMD). This implies that T2D is explained by poorer bone quality, whereby the intrinsic properties of the bone tissue itself are impaired, rather than bone mass. Yet, the mechanics remain unclear. The objective of this study is to (1) assess the fracture mechanics of bone at the structural and tissue level; and (2) investigate for changes in the composition of bone tissue along with measuring total fluorescent advanced glycation end products (fAGEs) from the skin, as T2D progresses with age in Zucker diabetic fatty (ZDF (fa/fa)) and lean Zucker (ZL (fa/+)) rats. Materials and Methods. Right ulnae and skin sections were harvested from ZDF (fa/fa) (T2D) and ZL (fa/+) (Control) rats at 12 and 46 weeks (wks) of age (n = 8, per strain and age) and frozen. Right ulnae were thawed for 12 hrs before micro-CT (μCT) scanning to assess the microstructure and measure BMD. After scanning, ulnae were loaded until failure via three-point bending. Fourier transform-infrared microspectroscopy (FTIR) was used to measure various bone mineral- and collagen-related parameters such as, mineral-to-matrix ratio and nonenzymatic cross-link ratio. Finally, fAGEs were measured from skin sections using fluorescence spectrometry and an absorbance assay, reported in units of ng quinine/ mg collagen. Results. At 12 and 46 wks bone size was significantly smaller in length (p < 0.01), cortical area (p < 0.001) and cross-sectional moment of inertia (p < 0.001) in T2D rats compared to age-matched controls. A slight reduction in BMD was observed in T2D rats compared to controls at both ages, however, this was not significant. Structural properties of T2D bone were significantly altered at 12 and 46 wks, with bending rigidity increasing approximately 2.5-fold and 1.5-fold in control and T2D rats with age, respectively (p < 0.0001). Similarly, yield and ultimate moment significantly reduced in T2D rats with age in comparison to controls (p < 0.0001). Energy absorbed to failure was significantly reduced in T2D rats at 46 weeks of age compared to controls (p < 0.01). The amount of energy absorbed to failure increased approximately 1.4-fold from 12 to 46 wks in control rats, however, in T2D rats a reduction was seen with age, although not significant. At 12 wks, there was no significant deficits in tissue material properties, whereas, at 46 wks a significant reduction in yield stress, yield strain and ultimate stress was observed for T2D rats in comparison to controls (p < 0.05). Conclusions. These findings show that longitudinal growth is impaired as early as 12 wks of age and by 46 wks bone size is significantly reduced in T2D rats compared to controls. The reduction in T2D structural properties is likely attributed to the bone geometry deficits. At 12 wks of age, the tissue material properties are not altered in T2D bone versus controls. However, at 46 wks, bone strength is reduced in T2D, leading to the conclusion that tissue properties are altered as the disease progresses


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_10 | Pages 6 - 6
1 Oct 2020
Maruyama M Moeinzadeh S Guzman RA Takagi M Yang YP Goodman SB
Full Access

Introduction. In early stage osteonecrosis of the femoral head (ONFH), core decompression (CD) is often performed; however, approximately 30% of CD cases progress to femoral head collapse. Bone healing can be augmented by preconditioning MSCs (pMSCs) with inflammatory cytokines. Another immunomodulatory approach is the timely resolution of inflammation using cytokines such as IL-4. We investigated the efficacy of pMSC and genetically modified MSCs that over-express IL-4 (IL4-MSCs) on steroid-associated ONFH in rabbits. Methods. Thirty-six male skeletally mature NZW rabbits received methylprednisolone acetate (20mg/kg) IM once 4 weeks before surgery. There were 6 groups:. CD alone – a 3 mm drill hole. + injection into the CD of:. hydrogel (HG) - 200 μl of hydrogel carrier. MSCs–1 million rabbit MSCs. pMSC - LPS (20 μg/ml) + TNFα (20 ng/ml) preconditioned MSCs. IL4-MSCs – rabbit IL-4 over-expressing MSCs. IL4-pMSCs – preconditioned IL-4 over-expressing MSCs. Eight weeks after surgery, femurs were harvested, and evaluated by microCT, biomechanical, and histological analyses. Results. Bone mineral density (BMD) and bone volume fraction (BVF) increased in the pMSC group compared to the CD and MSC groups . outside. of the CD area (p < 0.05, Fig.1). Similarly, the IL4-pMSC group was increased compared to the CD group (p < 0.05). The percentage of empty lacunae in the IL4-MSC group was significantly less than other groups . outside. the CD area (p < 0.05, Fig.2); however, IL4-MSC group had less trabecular bone formation . inside. the CD. The mechanical tests demonstrated no differences. Discussion. This rabbit steroid-associated ONFH model demonstrated that pMSC increased new bone formation after CD; IL4-MSCs that continuously secreted IL-4 decreased the number of empty lacunae . Immunomodulation of bone healing has the potential to improve bone healing after CD for early stage ONFH; these interventions must be applied in a temporally sensitive fashion. For any figures, tables, or references, please contact the authors directly


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_4 | Pages 19 - 19
1 Mar 2021
Mischler D Schader JF Windolf M Varga P
Full Access

To date, the fixation of proximal humeral fractures with angular stable locking plates is still insufficient with mechanical failure rates of 18% to 35%. The PHILOS plate (DePuy Synthes, Switzerland) is one of the most used implants. However, this plate has not been demonstrated to be optimal; the closely symmetric plate design and the largely heterogeneous bone mineral density (BMD) distribution of the humeral head suggest that the primary implant stability may be improved by optimizing the screw orientations. Finite element (FE) analysis allows testing of various implant configurations repeatedly to find the optimal design. The aim of this study was to evaluate whether computational optimization of the orientation of the PHILOS plate locking screws using a validated FE methodology can improve the predicted primary implant stability. The FE models of nineteen low-density (humeral head BMD range: 73.5 – 139.5 mg/cm3) left proximal humeri of 10 male and 9 female elderly donors (mean ± SD age: 83 ± 8.8 years) were created from high-resolution peripheral computer tomography images (XtremeCT, Scanco Medical, Switzerland), using a previously developed and validated computational osteosynthesis framework. To simulate an unstable mal-reduced 3-part fracture (AO/OTA 11-B3.2), the samples were virtually osteotomized and fixed with the PHILOS plate, using six proximal screws (rows A, B and E) according to the surgical guide. Three physiological loading modes with forces taken from musculoskeletal models (AnyBody, AnyBody Technology A/S, Denmark) were applied. The FE analyses were performed with Abaqus/Standard (Simulia, USA). The average principal compressive strain was evaluated in cylindrical bone regions around the screw tips; since this parameter was shown to be correlated with the experimental number of cycles to screw cut-out failure (R2 = 0.90). In a parametric analysis, the orientation of each of the six proximal screws was varied by steps of 5 in a 5×5 grid, while keeping the screw head positions constant. Unfeasible configurations were discarded. 5280 simulations were performed by repeating the procedure for each sample and loading case. The best screw configuration was defined as the one achieving the largest overall reduction in peri-screw bone strain in comparison with the PHILOS plate. With the final optimized configuration, the angle of each screw could be improved, exhibiting significantly smaller average bone strain around the screw tips (range of reduction: 0.4% – 38.3%, mean ± SD: 18.49% ± 9.56%). The used simulation approach may help to improve the fixation of complex proximal humerus fractures, especially for the target populations of patients at high risk of failure


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_8 | Pages 39 - 39
1 Aug 2020
Ma C Li C Jin Y Lu WW
Full Access

To explore a novel machine learning model to evaluate the vertebral fracture risk using Decision Tree model and train the model by Bone Mineral Density (BMD) of different compartments of vertebral body. We collected a Computed Tomography image dataset, including 10 patients with osteoporotic fracture and 10 patients without osteoporotic fracture. 40 non-fracture Vertebral bodies from T11 to L5 were segmented from 10 patients with osteoporotic fracture in the CT database and 53 non-fracture Vertebral bodies from T11 to L5 were segmented from 10 patients without osteoporotic fracture in the CT database. Based on the biomechanical properties, 93 vertebral bodies were further segmented into 11 compartments: eight trabecular bone, cortical shell, top and bottom endplate. BMD of these 11 compartments was calculated based on the HU value in CT images. Decision tree model was used to build fracture prediction model, and Support Vector Machine was built as a compared model. All BMD data was shuffled to a random order. 70% of data was used as training data, and 30% left was used as test data. Then, training prediction accuracy and testing prediction accuracy were calculated separately in the two models. The training accuracy of Decision Tree model is 100% and testing accuracy is 92.14% after trained by BMD data of 11 compartments of the vertebral body. The type I error is 7.14% and type II error is 0%. The training accuracy of Support Vector Machine model is 100% and the testing accuracy is 78.57%. The type I error is 17.86% and type II error is 3.57%. The performance of vertebral body fracture prediction using Decision Tree is significantly higher than using Support Vector Machine. The Decision Tree model is a potential risk assessment method for clinical application. The pilot evidence showed that Decision Tree prediction model overcomes the overfitting drawback of Support Vector Machine Model. However, larger dataset and cohort study should be conducted for further evidence


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 11 | Pages 1509 - 1514
1 Nov 2010
Smolders JMH Hol A Rijnders T van Susante JLC

We undertook a randomised prospective follow-up study of changes in peri-prosthetic bone mineral density (BMD) after hip resurfacing and compared them with the results after total hip replacement. A total of 59 patients were allocated to receive a hip resurfacing (n = 29) or an uncemented distally fixed total hip replacement (n = 30). The BMD was prospectively determined in four separate regions of interest of the femoral neck and in the calcar region corresponding to Gruen zone 7 for the hip resurfacing group and compared only to the calcar region in the total hip replacement group. Standardised measurements were performed pre-operatively and after three, six and 12 months. The groups were well matched in terms of gender distribution and mean age. The mean BMD in the calcar region increased after one year to 105.2% of baseline levels in the resurfaced group compared with a significant decrease to 82.1% in the total hip replacement group (p < 0.001) by 12 months. For the resurfaced group, there was a decrease in bone density in all four regions of the femoral neck at three months which did not reach statistical significance and was followed by recovery to baseline levels after 12 months. Hip resurfacing did indeed preserve BMD in the inferior femoral neck. In contrast, a decrease in the mean BMD in Gruen zone 7 followed uncemented distally fixed total hip replacement. Long term follow-up studies are necessary to see whether this benefit in preservation of BMD will be clinically relevant at future revision surgery


The Bone & Joint Journal
Vol. 95-B, Issue 11 | Pages 1480 - 1483
1 Nov 2013
Hooper GJ Gilchrist N Maxwell R March R Heard A Frampton C

We studied the bone mineral density (BMD) and the bone mineral content (BMC) of the proximal tibia in patients with a well-functioning uncemented Oxford medial compartment arthroplasty using the Lunar iDXA bone densitometer. Our hypothesis was that there would be decreased BMD and BMC adjacent to the tibial base plate and increased BMD and BMC at the tip of the keel. There were 79 consecutive patients (33 men, 46 women) with a mean age of 65 years (44 to 84) with a minimum two-year follow-up (mean 2.6 years (2.0 to 5.0)) after unilateral arthroplasty, who were scanned using a validated standard protocol where seven regions of interest (ROI) were examined and compared with the contralateral normal knee. All had well-functioning knees with a mean Oxford knee score of 43 (14 to 48) and mean Knee Society function score of 90 (20 to 100), showing a correlation with the increasing scores and higher BMC and BMD values in ROI 2 in the non-implanted knee relative to the implanted knee (p = 0.013 and p = 0.015, respectively). The absolute and percentage changes in BMD and BMC were decreased in all ROIs in the implanted knee compared with the non-implanted knee, but this did not reach statistical significance. Bone loss was markedly less than reported losses with total knee replacement. There was no significant association with side, although there was a tendency for the BMC to decrease with age in men. The BMC was less in the implanted side relative to the non-implanted side in men compared with women in ROI 2 (p = 0.027), ROI 3 (p = 0.049) and ROI 4 (p = 0.029). The uncemented Oxford medial compartment arthroplasty appears to allow relative preservation of the BMC and BMD of the proximal tibia, suggesting that the implant acts more physiologically than total knee replacement. Peri-prosthetic bone loss is an important factor in assessing long-term implant stability and survival, and the results of this study are encouraging for the long-term outcome of this arthroplasty. Cite this article: Bone Joint J 2013;95-B:1480–3


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_7 | Pages 40 - 40
1 Jul 2020
Farzi M Pozo JM McCloskey E Eastell R Frangi A Wilkinson JM
Full Access

In conventional DXA (Dual-energy X-ray Absorptiometry) analysis, pixel bone mineral density (BMD) is often averaged at the femoral neck. Neck BMD constitutes the basis for osteoporosis diagnosis and fracture risk assessment. This data averaging, however, limits our understanding of localised spatial BMD patterns that could potentially enhance fracture prediction. DXA region free analysis (RFA) is a validated toolkit for pixel-level BMD analysis. We have previously deployed this toolkit to develop a spatio-temporal atlas of BMD ageing in the femur. This study aims first to introduce bone age to reflect the overall bone structural evolution with ageing, and second to quantify fracture-specific patterns in the femur. The study dataset comprised 4933 femoral DXA scans from White British women aged 75 years or older. The total number of fractures was 684, of which 178 were reported at the hip within a follow-up period of five years. BMD maps were computed using the RFA toolkit. For each BMD map, bone age was defined as the age for which the L2-norm between the map and the median atlas at that age is minimised. Next, bone maps were normalised for the estimated bone age. A t-test followed by false discovery rate (FDR) analysis was applied to compare between fracture and non-fracture groups. Excluding the ageing effect revealed subtle localised patterns of loss in BMD oriented in the same direction as principal tensile curves. A new score called f-score was defined by averaging the normalised pixel BMD values over the region with FDR q-value less than 1e–6. The area under the curve (AUC) was 0.731 (95% confidence interval (CI)=0.689–0.761) and 0.736 (95% CI=0.694–0.769) for neck BMD and f-score. Combining bone age and f-score improved the AUC significantly by 3% (AUC=0.761, 95% CI=0.756–0.768) over the neck BMD alone (AUC=0.731, 95% CI=0.726–0.737). This technique shows promise in characterizing spatially-complex BMD changes, for which the conventional region-based technique is insensitive. DXA RFA shows promise to further improve fracture prediction using spatial BMD distribution


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_14 | Pages 3 - 3
1 Nov 2018
Ike H Inaba Y Kobayashi N Choe H Tezuka T Kobayashi D Watanabe S Higashihira S
Full Access

SL-PLUS MIA stem (Smith & Nephew Orthopaedics AG) is a modified implant of Zweymuller type SL-PLUS standard stem (Smith & Nephew Orthopaedics AG). We constructed finite element (FE) models and analysed equivalent stresses in the femur. In addition, we measured bone mineral density (BMD) in the femur by dual-energy X-ray absorptiometry (DEXA) after THA. The purpose of this study was to investigate the equivalent stress and to compare the results of the FE analyses with changes in BMD after THA. Twenty-one patients (18 women and 3 men) who underwent primary cementless THA with SL-PLUS MIA or SL-PLUS formed the basis of this study. Eleven patients received SL-PLUS MIA and ten patients received SL-PLUS. Zones were defined according to Gruen's system (zones 1∼7). Computed-tomography (CT) images of the femur were taken before and at 1 week after THA. FE models of the femur and prosthesis were obtained from CT data by Mechanical Finder (Research Center of Computational Mechanics Inc., Tokyo, Japan), software that creates FE models showing individual bone shape and density distribution. Equivalent stresses were analysed in zones 1 to 7 and compared to the DEXA data. FE studies revealed that there was no significant difference in equivalent stress between SL-PLUS MIA and SL-PLUS. BMD was maintained after THA in zones 3, 4, and 5, whereas BMD decreased in zones 2, 6, and 7. In zone 1, BMD decreased in SL-PLUS MIA stem group by 14%, while BMD was maintained in SL-PLUS standard stem


The Bone & Joint Journal
Vol. 100-B, Issue 9 | Pages 1175 - 1181
1 Sep 2018
Benca E Willegger M Wenzel F Hirtler L Zandieh S Windhager R Schuh R

Aims. The traditional transosseus flexor hallucis longus (FHL) tendon transfer for patients with Achilles tendinopathy requires two incisions to harvest a long tendon graft. The use of a bio-tenodesis screw enables a short graft to be used and is less invasive, but lacks supporting evidence about its biomechanical behaviour. We aimed, in this study, to compare the strength of the traditional transosseus tendon-to-tendon fixation with tendon-to-bone fixation using a tenodesis screw, in cyclical loading and ultimate load testing. Materials and Methods. Tendon grafts were undertaken in 24 paired lower-leg specimens and randomly assigned in two groups using fixation with a transosseus suture (suture group) or a tenodesis screw (screw group). The biomechanical behaviour was evaluated using cyclical and ultimate loading tests. The Student’s t-test was performed to assess statistically significant differences in bone mineral density (BMD), displacement, the slope of the load-displacement curves, and load to failure. Results. The screw group showed less displacement (loosening) during cyclical loading, which was significant during 300, 500, 600, 700, 800, 900, and 1000 cycles (p < 0.05: other cycles: 0.079 < p < 0.402). Compared with the suture group, the screw group had higher mean ultimate load values (133.6 N, . sd. 73.5 vs 110.1 N,. sd. 46.2; p = 0.416). Conclusion. Fixation of the FHL tendon with a tenodesis screw enables a less invasive procedure to be undertaken and shows similar biomechanical behaviour and primary strength compared with fixation using a transosseus suture. Cite this article: Bone Joint J 2018;100-B:1175–81


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_16 | Pages 99 - 99
1 Nov 2018
Mizrak S Turan V Inan S Uysal A Yilmaz C Gürdal M Ercan G
Full Access

To prevent bone loss, OPG/RANK/RANKL signalling pathway is a key in keeping the balance between the action of osteoblasts and osteoclasts. Aim of this study is to assess the influence of long-term nicotine exposure on bone mineral density (BMD) scores, RANKL and OPG levels of plasma and RANKL and OPG immunoreactivities of tissue in rats. In this study, totally 36 Swiss Albino rats (70±10 g) were used in three groups. Whereas normal drinking water was given for the control group (n:12), 0.4 mg/kg/day and 6.0 mg/kg/day nicotine was added to drinking water for low-dose nicotine (LDN) group (n:12) and high-dose nicotine (HDN) group (n:12), respectively for 12 months. At the end of 12. th. month, BMD scores were measured via X-ray absorptiometry and then bone turnover was assessed via measuring both RANKL, OPG levels in plasma and RANKL, OPG immunoreactivities in tail vertebrae of all rats. Lumbar spine and femoral regions BMD scores of the control group and the nicotine groups were not significantly difference. In HDN group, OPG levels of plasma were found significantly higher when compared with the control and LDN groups (p=0.001) unlike RANKL levels of plasma. RANKL and OPG immunoreactivities of tissue were found significantly lower in both LDN and HDN groups (p<0.001, p=0.004, respectively) in comparison to control group. No correlation was found between plasma levels and tissue immunoreactivities of RANKL and OPG. As a result, this study indicates that nicotine is not primarily responsible for the decline of BMD frequently seen in smokers


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_10 | Pages 50 - 50
1 Oct 2020
Kraay MJ Bigach SD Rimnac CM Moore RD Kolevar MP Adavi P
Full Access

Introduction. The purpose of this study was to evaluate the long term changes in bone mineral density (BMD) following implantation of a low-modulus composite femoral component designed to closely match the stiffness of the proximal femur and minimize stress shielding. Specifically, we asked: 1) How does BMD in the proximal femur change with time and with Gruen zone location; 2) Does BMD in the proximal femur stabilize after two years of implantation?. Methods. We retrospectively reviewed a subgroup of sixteen patients who had preoperative and postoperative DEXA scans in an FDA multi-center prospective trial of this composite stem. Five of these sixteen patients returned for long-term DEXA scans at a mean 22.0 years post-op (range 21.2–22.6 years). BMD in the 7 Gruen zones at final follow-up was compared to immediate post-operative and 2-year follow-up values. Percentage change was calculated and change in BMD was plotted against time from immediate post-operative measurements to each subsequent follow-up. Results. At the time of last follow-up, all stems were well fixed with signs of extensive osteointegration. There were no mechanical implant failures. In Gruen zone 1, patients underwent an overall decrease or little change in BMD, though one patient experienced a notable increase from initial post-op to the latest follow-up. The overall mean (+ SD) annual percent change in BMD in Gruen zone 1 was −0.31% ± 1.09%. When considering the change from the two-year DEXA scan to latest follow-up, two patients demonstrated a decrease in BMD and three patients demonstrated an increase in BMD in Gruen zone 1. All patients demonstrated progressive increase in BMD in Gruen zones 2, 3, 4, 5, and 6 from the initial post-op scan until last follow-up with mean annual percent changes ranging from 0.59% ± 0.50% in Gruen zone 6 to 2.78% ± 2.49% in Gruen zone 3. In our cohort, BMD progressively decreased with time in Gruen zone 7 for all patients with a mean decrease of 1.78% + 0.38% annually from the time of the initial post-op DEXA scan until last follow-up. This was consistent with prior reports with shorter term follow-up. Conclusions. Despite the extensively porous coated design of this stem and concerns about distal fixation and related stress shielding, we observed consistent DEXA scan evidence of increases in BMD in Gruen zones 2–6 and limitation of decreases in BMD exclusively to zone 7 and to a lesser extent zone 1. This is unlike reported results with several other extensively porous coated and proximally porous coated implants designed to obtain proximal fixation. These increases in BMD occurred despite the potential age-related decreases in BMD in the proximal femur that one would anticipate over the mean 22-year follow-up in this study. Clearly, “normal” physiologic loading of bone after THA is determined by a complex interaction between location of ingrowth, location and extent of endosteal contact of the implant in the proximal femur, stiffness of the stem and other implant design and patient related factors. The long-term observations of this study suggest that effective loading of the proximal femur occurs with this low-modulus stem and that this concept may have a role in the future of THA


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_9 | Pages 69 - 69
1 Oct 2020
Lawrie CM Barrack RL Nunley RM
Full Access

Introduction. Bone mineral density (BMD) is correlated with component migration and aseptic loosening after total knee arthroplasty (TKA). Older implant designs have demonstrated BMD loss up to 23% in the first 6 months after TKA, and continued to BMD decline at an average of 5% per year for as long as 2 years after TKA. The impact of component design and fixation method on BMD loss after TKA in modern implant designs has not been fully elucidated. The purpose of this study is to determine the effect of tibial tray thickness and fixation method (cemented versus cementless) on BMD loss patterns of the proximal tibia in two different modern TKA implant systems. Methods. A prospective, nonrandomized, single center study of patients undergoing primary TKA by one of two surgeons was performed with four study cohorts: cemented DePuy Attune, cementless DePuy Attune, cemented Stryker Triathlon, cementless Stryker Triathlon. Target sample size was 80, with 20 per cohort based on adhoc power analysis. Exclusion criteria included: age over 75, BMI >40, inflammatory arthritis, previous knee surgery involving the femur, tibia or tibial bone, and diagnosis of osteopenia/osteoporosis. Implant fixation type was based on surgeon intraoperative assessment of patient bone quality. Demographic data was collected preoperatively. Dual Energy X-ray Absorptiometry (DEXA) Bone Density Monitoring was performed at 6 weeks and one year postoperatively. Bone mineral density was calculated from the DEXA scans for 4 zones for the tibia relative to the keel or central peg: anterior, posterior, medial and lateral. Results were reported as BMD at 1 year postoperatively as a percentage of BMD at 6 weeks postoperatively. Results. 81 knees with complete DEXA studies at 6 weeks and 1 year postoperatively were available for analysis. The mean (SD) age at the time of surgery was 65.4 years (6.1), with 39 men and 42 women and a mean (SD) BMI of 31.2 kg/m. 2. (4.7). The patients who received cementless implants were significantly younger with a mean (SD) age of 62.1 (6.0) than those who received cemented implants with a mean age of 69.1 (3.7) (p < 0.05). There was no difference in age between implant type (p > 0.05). There was no difference in BMI or gender distribution between implant types or fixation type (p > 0.05). There was no significant difference in mean BMD loss between 6 weeks and 1 year postoperatively between the cemented and cementless Triathlon in any zone, between the cemented Triathlon and Attune in any zone, the cementless Triathlon and Attune in any zone, and the cemented and cementless attune in the lateral, anterior and posterior proximal tibia (p > 0.05). There was significantly more BMD loss seen in the medial tibia in the cemented (BMD at 1 year 88% of BMD at 6 weeks) than cementless (BMD at 1 year 103% of BMD at 6 weeks) Attune (p = 0.043). Conclusion. BMD loss at 1 year postoperatively versus 6 weeks postoperatively after TKA with two modern implant designs is not significantly affected by tibial tray thickness. BMD loss was unaffected by fixation type for the Stryker Triathlon, but was significant less for the cementless DePuy Attune than the cemented version


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_34 | Pages 15 - 15
1 Dec 2013
Berahmani S Janssen D Wolfson D De Waal Malefijt M Verdonschot N
Full Access

The effect of an advanced porous surface morphology on the mechanical performance of an uncemented femoral knee prosthesis was investigated. Eighteen implants were inserted and then pushed-off from nine paired femurs (Left legs: advanced surface coating; right legs: Porocoat® surface coating as baseline). Bone mineral density (BMD) and anteroposterior dimension were measured, which both were not significantly different between groups. The insertion force was not significantly different, but push-off force was significantly higher in the advanced surface coating group (P = 0.007). BMD had direct relationship with the insertion force and push-off force (p < 0.001). The effect of surface morphology on implant alignment was very small. We suggest that the surface properties create a higher frictional resistance thereby providing a better inherent stability of implants featuring the advanced surface coating


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_4 | Pages 8 - 8
1 Apr 2018
Wang FS Sun YC Ko JY
Full Access

Introduction. Excessive bone mass and microarchitecture loss exacerbate the risk of osteoporotic fracture, a skeletal disorder attributable to disability in the elder. Excessive marrow adipose development at the expense of osteoblastic bone acquisition is a prominent feature of aging-induced osteoporotic skeletons. MicroRNA-29a (miR-29a) modulates osteogenic and adipogenic commitment of mesenchymal progenitor cells. The purposes of this study were to test if miR-29a overexpression changed bone mass or microstructure in aged skeletal tissues. Materials/Methods. Transgenic mice that overexpressed miR-29a in osteoblasts driven by osteocalcin promoter (miR-29aTg) were generated. Littermates without carrying construct of interest were used as wild-type mice (WT). 3- and 12-month-old mice were designated into young and aged groups respectively. Bone mineral density (BMD), cortical, trabecular microarchitecture and morphometric profiles were quantified with ultrahigh resolution μCT system. Primary bone-marrow mesenchymal stem cells (BMMSCs) were incubated in osteogenic and adipogenic conditions. Expressions of osteogenic and adipogenic marker were quantified with RT-PCR. Results. Skeletons in the aged WT group showed 65% decrease in BMD in association with 72% reduction in miR-29a expression and 2.3-fold elevation in marrow fat volume as compared with those in young WT group. The young miR-29aTg mice showed 35–48% increases in serum osteocalcin and bone alkaline phosphatase levels concomitant with 22–35% increases in BMD, trabecular BV/TV, Tb.Th, Tb.N, and cortical morphology than those of young WT mice. Intriguing analyses are that miR-29aTg mice exhibited mild responses to the aging provocation of BMD loss, trabecular, cortical microstructure deterioration, and fatty marrow histopathology. In vitro, primary BMMSCs in miR-29aTg mice showed significant increases in osteogenic gene expression and mineralized matrices as probed with von Kossa staining, whereas adipogenic gene expression and adipocyte formation were evidently reduced as evidenced by fluorescence Nile Red. Conclusion. miR-29a overexpression in osteoblasts facilitates skeletal tissue anabolism. High osteogenic lineage commitment of bone-marrow mesenchymal progenitor cells contributes to high bone mass and microstructure phenotypes promoted by miR-29a signaling. Analyses shed a new light on the miR-29a signaling protection against the aging escalation of osteoporosis pathogenesis


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_11 | Pages 3 - 3
1 Aug 2018
Barrack R Nam D Salih R Nahhas C Nunley R
Full Access

To assess clinical outcomes, metal ion levels, and periprosthetic femoral bone mineral density (BMD) in young, active patients receiving a modular dual mobility acetabulum and recently introduced titanium, proximally coated, tapered femoral stem design. This was a prospective study of patients  65 years of age, with a BMI  35 kg/m. 2. , and UCLA activity score > 6 who received a modular cobalt chrome acetabular liner, highly cross-linked polyethylene mobile bearing, and cementless titanium femoral stem for their primary THA. Patients with a history of renal disease and metal hardware elsewhere in the body were excluded. All patients had a minimum of 2-year clinical follow-up. Patient reported outcome measures, whole blood metal ion levels (ug/L), and periprosthetic femur BMD were measured at baseline and at 1- and 2-years postoperatively. 43 patients (30 male, 13 female; mean age 52.6 ± 6.5 years) were enrolled. Harris Hip Scores improved from 54.1 ± 20.5 to 91.2 ± 10.8 at 2 years postoperatively (p<0.001). All patients had radiographically well-fixed components, no patients have sustained an instability event, and no patients have required a return to the operating room or revision procedure. Mean cobalt levels increased from 0.065 ± 0.03 ug/L preoperatively to 0.30 ± 0.51 at 1-year postoperatively (p=0.01), but decreased at 2 years postoperatively to 0.16 ± 0.23 (p=0.2) (Table 1). Four patients (9.3%) had a cobalt level outside the reference range (0.03 to 0.29ug/L) at 2 years postoperatively with values from 0.32 to 0.94. None were symptomatic. The mean femoral BMD ratio was maintained in Gruen zones 2 thru 7 at both 1- and 2-years postoperatively using this stem design (Table 2). At 2 years postoperatively, BMD in the medial calcar was 101.5% of the baseline value. Use of a modular dual mobility prosthesis and cementless, tapered femoral stem has shown encouraging results in young, active patients undergoing primary THA. Elevation in mean cobalt levels and the presence of four patients outside the reference range at 2 years postoperatively demonstrates the necessity of continued surveillance in this cohort. For any figures or tables, please contact authors directly: . barrackr@wustl.edu


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_3 | Pages 74 - 74
1 Apr 2018
Chevalier Y Chamseddine M Santos I Müller P Pietschmann M
Full Access

Introduction. Glenoid loosening, still a main complication for shoulder arthroplasty, was suggested to be related implant design, surgical aspects, and also bone quality. However, typical studies of fixation do not account for heterogeneity in bone morphology and density which were suggested to affect fixation failure. In this study, a combination of cyclic rocking horse tests on cadaver specimens and microCT-based finite element (microFE) analysis of specimens of a wide range of bone density were used to evaluate the effects of periprosthetic bone quality on the risks of loosening of anatomical keeled or pegged glenoid implants. Methods. Six pairs of cadaveric scapulae, scanned with a quantitative computer tomography (QCT) scanner to calculate bone mineral density (BMD), were implanted with either cemented anatomical pegged or keeled glenoid components and tested under constant glenohumeral load while a humeral head component was moved cyclically in the inferior and superior directions. Edge displacements were measured after 1000, 4000 and 23000 test cycles, and tested for statistical differences with regards to changes or implant design. Relationships were established between edge displacements and QCT-based BMD below the implant. Four other specimens were scanned with high-resolution peripheral QCT (82µm) and implanted with the same 2 implants to generate virtual models. These were loaded with constant glenohumeral force, varying glenohumeral conformity and superior or inferior load shifts while internal stresses at the cement-bone and implant-cement interfaces were calculated and related to apparent bone density in the periprosthetic zone. Results. Mean displacements at the inferior and superior edges showed no statistical difference between keeled and pegged designs (p>0.05). Compression and distraction were however statistically different from the initial reference measurement at even 1000 and 4000 cycles for both implant designs (p<0.05). For both implant designs, superior and inferior distractions were generally highest at each measurement time in specimens where BMD below the lifting edge was lower, showing a trend of increased distraction with decreased BMD. Moreover, the microFE models predicted higher bone and cement stresses for specimens of lower apparent bone density. Finally, highest peak stresses were located at the cement-bone interface, which seemed the weaker part of the fixation. Discussion. With this combined experimental and numerical study, it was shown that implant distraction and stresses in the cement layer are greater in glenoids of lower bone density for both implant designs. This indicates that fixation failure will most likely occur in bone of lower density, and that fixation design itself may play a secondary role. These results have important impact for understanding the mechanisms of glenoid component failure, a common complication of total shoulder arthroplasty


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_8 | Pages 20 - 20
1 Apr 2017
Meijer M Boerboom A Stevens M Reininga I Janssen D Verdonschot N
Full Access

Background. Trabecular metal (TM) cones are designed to fill up major bone defects in total knee arthroplasty. Tibial components can be implanted in combination with a stem, but it is unclear if this is necessary after reconstruction with a TM cone. Implanting a stem may give extra stability, but may also have negative side-effects. Aim of this study was to investigate stability and strain distribution of a tibial plateau reconstruction with a TM cone while the tibal component is implanted with and without a stem, and whether prosthetic stability was influenced by bone mineral density (BMD). Methods. Tibial revision arthroplasties were performed after reconstruction of an AORI 2B bone defect with TM cones. Plateaus were implanted in seven pairs of cadaveric tibiae; of each pair, one was implanted with and the other without stem. All specimens were loaded to one bodyweight alternating between the medial and lateral tibia plateau. Implant-bone micro motions, bone strains, BMD and correlations were measured and/or calculated. Results. Tibial components without a stem showed only more varus tilt (difference in median 0.14 degrees (P<0.05), but this was not considered clinically relevant. Strain distribution did not differ. BMD had only an effect on the anterior/posterior tilt ρ:-0.72 (P<0.01). Conclusions. Tibial components, with or without a stem, which are implanted after reconstruction of major bone defects using TM cones produce very similar biomechanical conditions in terms of stability and strain distribution. Additional stem extension of the tibial component may not be required after reconstruction of major bone defects using TM cones. Level of evidence. IIb. Disclosures. The department of Orthopaedics, University of Groningen, University Medical Center Groningen has received direct funding from the Anna Fonds (Oegstgeest, NL). Zimmer (Warsaw, IN, USA) has provided the instrumentation and tools for this study. The department of Orthopaedics, University of Groningen, University Medical Center Groningen receives research institutional support from InSpine (Schiedam, NL) and Stryker (Kalamazoo, Mich. USA). One of the authors (ALB) will be and has been paid as a consultant by Zimmer (Warsaw, IN, USA) for purposes of education and training in knee arthroplasty


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_16 | Pages 48 - 48
1 Oct 2016
Dobson P Greaves L Deehan D Turnbull D
Full Access

The pathogenesis of falling bone mineral density (BMD) as a universal feature of advancing age is poorly understood. 1. Frequently culminating in the development of osteoporosis, the process is attributable to more than 500,000 fragility fractures occurring every year in the UK Such injuries are associated with great levels of morbidity, mortality and a £3.5 billion cost to the healthcare economy. 2. . With age, humans are known to accumulate somatic mitochondrial DNA (mtDNA) mutations in mitotic and post mitotic tissue, and stem cell precursors. 3. Compelling evidence in recent years, particularly that provided by animal models suggests that these mutations are intrinsic to the ageing process. 4–6. We provide evidence for the first time that mitochondrial dysfunction contributes significantly to the failure of bone homeostasis and falling BMD. We have utilised a mouse model that accumulates mtDNA mutations at 3–5 times the rate of normal mice, consequently ageing and developing osteoporosis prematurely. 7. , to clearly demonstrate that osteoblasts are vulnerable to mtDNA mutations. We have developed a new quadruple immunofluorescent assay to show that mitochondrial respiratory chain dysfunction occurs in osteoblasts as a consequence (p < 0.0001). We show that this mitochondrial dysfunction is associated with reduced BMD in female and male mice by 7 (p = 0.003) and 11 (p = 0.0003) months of age respectively. Using osteoblasts derived from mesenchymal stem cells extracted from male and female mice with mitochondrial dysfunction aged 4, 7 and 11 months, we demonstrate a vastly reduced capacity to produce new mineralised bone in vitro when compared to wild type cell lines (p < 0.0001). Exercise was found to have no beneficial effect on osteoblast and whole bone phenotype in this mouse model. It is likely that mtDNA mutations accumulating over a longer time period in human ageing have significantly detrimental effects on bone biology and diminishing BMD


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_3 | Pages 3 - 3
1 Feb 2017
Abel R Hansen U Cobb J
Full Access

Bones are thought to become fragile with advancing age due to a loss of mass and structure. However, there are important aspects of bone fragility and fracture that cannot be explained simply by a loss of bone: 30% of all patients told they have healthy bone based on bone mineral density (BMD) measurements go on to fracture. It has been suggested that increased fracture risk might also be due to ageing at the nanoscale, which might deteriorate the overall mechanical properties of a bone. However, it is not clear how mechanics at the level of the collagen-mineral matrix relate to mechanical properties of the whole bone, or whether nano-mechanics contribute to fracture risk. In order to answer these questions our group is developing state of the art methods for analysing the structure and function of the collagen mineral matrix under loading. To image the collagen mineral matrix we obtained beam time on a synchrotron particle accelerator at the Diamond Light Source (Didcot, UK). Electrons are accelerated to near light speed by powerful electromagnets, then slowed to create high energy monochromatic X-Ray beams. Through a combination of X-Ray computed tomography and X-Ray diffraction we have been able to image the collagen/mineral matrix. Furthermore, using in situ loading experiments it has been possible to visualise collagen fibrillar sliding and mineral crystal structure. Our group is analysing how age related changes in nano-structure affect bone mechanical behaviour. As well as comparing fragility fracture patients with ‘healthy’ age matched controls to investigate whether ageing at the nano-scale could increase fracture risk. We are also assessing the effect of common treatments for bone fragility (e.g. bisphosphonate) on nano-mechanics. Unfortunately the expense and high radiation dose associated with synchrotron imaging prevents the technology from being adapted for patients. Therefore the next step will be to identify and test tools that can be used to indirectly assess bone chemistry and mechanical properties at point of care (e.g. laser spectroscopy and indentation). The data could be used to improve the diagnosis, monitoring and treatment of bone fragility


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_5 | Pages 22 - 22
1 Apr 2019
Massari L Bistolfi A Grillo PP Causero A
Full Access

Introduction. Trabecular Titanium is a biomaterial characterized by a regular three-dimensional hexagonal cell structure imitating trabecular bone morphology. Components are built via Electron Beam Melting technology in aone- step additive manufacturing process. This biomaterial combines the proven mechanical properties of Titanium with the elastic modulus provided by its cellular solid structure (Regis 2015 MRS Bulletin). Several in vitro studies reported promising outcomes on its osteoinductive and osteoconductive properties: Trabecular Titanium showed to significantly affect osteoblast attachment and proliferation while inhibiting osteoclastogenesis (Gastaldi 2010 J Biomed Mater Res A, Sollazzo 2011 ISRN Mater Sci); human adipose stem cells were able to adhere, proliferate and differentiate into an osteoblast-like phenotype in absence of osteogenic factors (Benazzo 2014 J Biomed Mater Res A). Furthermore, in vivo histological and histomorphometric analysis in a sheep model indicated that it provided bone in-growth in cancellous (+68%) and cortical bone (+87%) (Devine 2012 JBJS). A multicentre prospective study was performed to assess mid-term outcomes of acetabular cups in Trabecular Titanium after Total Hip Arthroplasty (THA). Methods. 89 patients (91 hips) underwent primary cementless THA. There were 46 (52%) men and 43 (48%) women, with a median (IQR) age and BMI of 67 (57–70) years and 26 (24–29) kg/m2, respectively. Diagnosis was mostly primary osteoarthritis in 80 (88%) cases. Radiographic and clinical evaluations (Harris Hip Score [HHS], SF-36) were performed preoperatively and at 7 days, 3, 6, 12, 24 and 60 months. Bone Mineral Density (BMD) was determined by dual-emission X-ray absorptiometry (DEXA) according to DeLee &Charnley 3 Regions of Interest (ROI) postoperatively at the same time-points using as baseline the measureat 1 week. Statistical analysis was carried out using Wilcoxon test. Results. Median (IQR) HHS and SF-36 improved significantly from 48 (39–61) and 49 (37–62) preoperatively to 99 (96–100) and 76 (60–85) at 60 mo. (p≤0.0001). Radiographic analysis showed evident signs of bone remodelling and biological fixation, with presence of superolateral and inferomedial bone buttress, and radial trabeculae in ROI I/II. All cups resulted radiographically stable without any radiolucent lines. The macro-porous structure of this biomaterial generates a high coefficient of friction (Marin 2012 Hip Int), promoting a firm mechanical interlocking at the implant-bone interface which could be already observed in the operating room. BMD initially declined from baseline at 7 days to 6 months. Then, BMD slightly increased or stabilized in all ROIs up to 24 months, while showing evidence of partial decline over time with increasing patient' age at 60 months, although without any clinical significance in terms of patients health status or implant stability. Statistical significant correlations in terms of bone remodeling were observed between groups of patients on the basis of gender and age (p≤0.05). No revision or implant failure was reported. Conclusions. All patients reported significant improvements in quality of life, pain relief and functional recovery. Radiographic evaluation confirmed good implant stability at 60 months. These outcomes corroborate the evidence reported on these cups by orthopaedic registries and literature (Perticarini 2015 BMC Musculoskelet Disord; Bistolfi 2014 Min Ortop)


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_8 | Pages 74 - 74
1 May 2016
Kanagawa H Kodama T Tsuji O Nakayama M Shiromoto Y Ogawa Y
Full Access

Introduction. We report a case which total knee arthroplasty (TKA) was able to be performed on schedule for the patient with occult fracture of proximal tibia which seemed to have occurred three months prior to the surgery, and has healed in short period of time by the use of Teriparatide. Case report. The patient is 84-year-old female, having right knee pain for past 7 years. Her knee pain increased by passive extension maneuver that was done by a bonesetter 3 months prior to the surgery. On her initial visit, the X-ray finding was severe medial osteoarthritis, and femorotibial angle (FTA) in the upright film was 197°, but there was no other disorder including fracture. Since the bone mineral density (BMD) of affected femoral neck was 62%YAM, and affected lateral femoral condyle as well as lateral tibial condyle seemed very porotic, we started using daily 20μg Teriparatide injection from 3 months prior to the surgery. Proximal tibial fracture was presented in the X-ray taken on the day before surgery, but since adequate bone union has already been formed, surgery was performed on schedule. Tibial implant with long stem was used for just to be certain. Thanks to the Teriparatide, the condition of cancellous bone in cut surface was excellent, and reaming of the tibia through fracture area felt very solid. Discussion. Proximal tibial fracture that occurred just before TKA is very rare. The fracture in this case was probably due to the maneuver done by the bonesetter. Teriparatide is indicated when osteoporosis is severe and the patient is at risk for fracture. We also indicate Teriparatide for the patients whose femoral neck BMD is very low and severe valgus knee or varus knee is present. Unloaded side of femoral or tibial condyle is usually very porotic in such a case. In our case, the fracture was so called fragility fracture which was found incidentally the day before surgery, but TKA could be done on schedule since adequate callus has been formed by the use of Teriparatide which started 3 months prior to the surgery


The Journal of Bone & Joint Surgery British Volume
Vol. 77-B, Issue 5 | Pages 815 - 819
1 Sep 1995
Cohen B Rushton N

We measured bone mineral density (BMD) in the proximal femur by dual-energy X-ray absorptiometry (DEXA) in 20 patients after cemented total hip arthroplasty over a period of one year. We found a statistically significant reduction in periprosthetic BMD after six months on the medial side and on the lateral side adjacent to the mid and distal thirds of the prosthesis. At one year after operation there was a mean 6.7% reduction in BMD in the region of the calcar and a mean 5.3% increase in BMD in the femoral shaft distal to the tip of the implant. These changes reflect a pattern of reduced stress in the proximal femur and increased stress around the tip of the prosthesis. They support current concepts of bone remodelling in the proximal femur in response to prosthetic implantation


The Journal of Bone & Joint Surgery British Volume
Vol. 80-B, Issue 3 | Pages 432 - 436
1 May 1998
Terauchi M Shirakura K Katayama M Higuchi H Takagishi K

We studied 37 patients with varus osteoarthritis of the knee to determine the influence of the bone mineral density (BMD) on the varus deformity. There were 15 men (21 knees) and 22 women (38 knees). The mean age of the men was 69 years and of the women 68 years. BMD was measured in the L1–L4 spinal region using dual X-ray absorptiometry. In the women a low level of BMD was associated with varus deformity originating at the proximal tibia, but a high level was predominantly linked with deformity originating in the joint space. Similar findings were obtained in the men. Our results suggest that a low BMD predisposes to trabecular microfractures and consequently increased stress on the articular cartilage. A low BMD does not preclude osteoarthritic change in the knee


The Journal of Bone & Joint Surgery British Volume
Vol. 85-B, Issue 3 | Pages 423 - 425
1 Apr 2003
Wigderowitz CA Cunningham T Rowley DI Mole PA Paterson CR

Fractures of the distal forearm are widely regarded as the result of “fragility”. We have examined the extent to which patients with Colles’ fractures have osteopenia. We measured the bone mineral density (BMD) in the contralateral radius of 235 women presenting with Colles’ fractures over a period of two years. While women of all ages had low values for ultra-distal BMD, the values, in age-matched terms, were particularly low among premenopausal women aged less than 45 years. This result was not due to the presence of women with an early menopause. This large survey confirms and extends the findings from earlier small studies. We consider that it is particularly important to investigate young patients with fractures of the distal forearm to identify those with osteoporosis, to seek an underlying cause and to consider treatment


The Journal of Bone & Joint Surgery British Volume
Vol. 85-B, Issue 2 | Pages 231 - 237
1 Mar 2003
Holzer G Krepler P Koschat MA Grampp S Dominkus M Kotz R

We studied the bone mineral density (BMD) of 48 long-term survivors of highly malignant osteosarcoma who had been treated according to the chemotherapy protocols of the German- Swiss-Austrian Co-operative Osteosarcoma Study Group which include high-dose methotrexate. The mean age of the patients was 31 ± 4.2 years and the mean follow-up 16 ± 2.2 years. The BMD of the lumbar spine and of the proximal femur of the non-operated side was measured by dual- energy x-ray absorptiometry. A questionnaire was given to determine life-style factors, medical history and medication. Ten patients were osteoporotic, 21 osteopenic and 17 normal according to the WHO definition. Eighteen patients suffered fractures after receiving chemotherapy and all had significantly lower levels of BMD for all the sites measured


The Journal of Bone & Joint Surgery British Volume
Vol. 77-B, Issue 3 | Pages 479 - 483
1 May 1995
Cohen B Rushton N

Dual-energy X-ray absorptiometry (DEXA) is increasingly used to measure changes in bone mineral density (BMD) around femoral prostheses after total hip arthroplasty. We have studied the factors which affect the accuracy of these measurements. The coefficient of variation was < 2% using a hydroxyapatite phantom, 2.7% in an anthropomorphic phantom specimen, and < 1% in repeated measurements on implanted cadaver femora. The precision did not vary with different implant materials or designs. In patients we found a mean precision error of 2.7% to 3.4%. The most significant factor affecting reproducibility was rotation of the femur. We conclude that DEXA is a precise method of measurement for small changes in BMD around femoral implants, but that correct and careful positioning of patients is essential to obtain reliable results


The Journal of Bone & Joint Surgery British Volume
Vol. 77-B, Issue 1 | Pages 143 - 147
1 Jan 1995
Zionts L Nash J Rude R Ross T Stott N

We used dual-energy X-ray absorptiometry (DEXA) to compare the bone mineral density (BMD) of nine children aged from 2 years 7 months to 13 years 5 months who had mild osteogenesis imperfecta with an age- and sex-matched control group. The patients had only mild clinical symptoms but DEXA detected highly significant differences in BMD between them and the controls. The mean BMD in the children with osteogenesis imperfecta was 76.7% of normal in the lumbar spine (p < 0.001) and 71.2% of normal in the femoral neck (p < 0.001). DEXA is an objective, reproducible and sensitive method of measurement of BMD in children. It may help to establish the diagnosis, to assess prognosis and possibly to monitor the response to different types of treatment


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_16 | Pages 43 - 43
1 Apr 2013
Boey J Tow B Yeo W Guo CM Yue WM Chen J Tan SB
Full Access

Introduction. The risk factors for new adjacent vertebral compression fracture (NAVCF) after Vertebroplasty (VP) or Kyphoplasty (KP) for osteoporotic vertebral compression fractures (VCFs) were investigated. Materials and methods. The authors retrospectively analyzed the incidence of NAVCFs in 135 patients treated with VP or KP for osteoporotic VCFs. Study period was from 2004 to 2008 with minimum follow-up of 2 years. Possible risk factors were documented: age, gender, body mass index, bone mineral density (BMD), co-morbidities, location of treated vertebra, treatment modality and amount of bone cement injected. Anterior-posterior vertebral body height ratio, intra-discal cement leakage into the disc space and pattern of cement distribution of the initial VCF and adjacent vertebral bodies were assessed on lateral thoracolumbar radiographs by 2 independent assessors. Results. 21 patients (15.6%) had subsequent symptomatic NAVCFs with a median time to new fracture was of 125 days. There was no difference in incidence of NAVCF between VP and KP groups (P>0.05). Significant differences were found between patients with and without NAVCF in terms of age, BMD, and the proportion of cement leakage into the disc space (P < 0.05). Greater age, intra-discal cement leakage and low BMD were found in patients with NAVCF. Conclusion. The most important risk factors affecting NAVCFs were age, osteoporosis and intra-discal cement leakage


Orthopaedic Proceedings
Vol. 87-B, Issue SUPP_III | Pages 276 - 276
1 Sep 2005
de Beer M Boon J van der Merwe A Scholtz M Becker P
Full Access

Loosening of the glenoid component after total shoulder arthroplasty is the most common indication for revision surgery and the reason for 40% of postoperative complications. Presupposing that implants would survive better in areas with higher bone mineral density (BMD), we aimed to determine BMD of the cancellous part of the glenoid and the dimensions of its cortical bone. Using spiral CT scans of the left and right shoulders of 45 men and 25 women with no shoulder pathology, we assessed the BMD of the anterior, middle and posterior subcortical planes of the cancellous part of the glenoid at the superior, middle and inferior levels. The cortical thickness was measured at corresponding sites. In both sexes, at all three levels we found the posterior plane had the highest BMD and cortical thickness. These findings indicate that BMD varies between planes and areas of cancellous bone in the glenoid. This may influence the engineering of future implants


The Journal of Bone & Joint Surgery British Volume
Vol. 79-B, Issue 4 | Pages 675 - 679
1 Jul 1997
Ang KC Das De S Goh JCH Low SL Bose K

In a prospective study of 14 patients undergoing total hip replacement we have used dual-energy X-ray absorptiometry (DEXA) to investigate remodelling of the bone around two different designs of cementless femoral prosthesis. The bone mineral density (BMD) was measured at 12-weekly intervals for a year. Eight patients (group A) had a stiff, collarless implant and six (group B) a flexible isoelastic implant. Patients in group A showed a decrease in BMD from 14 weeks after operation. By 12 months, the mean loss in BMD was 27%, both medially and laterally to the proximal part of the implant. Those in group B showed an overall increase in BMD which reached a mean of 12.6% on the lateral side of the distal portion of the implant. Our results support the current concepts of the effects of stem stiffness and flexibility on periprosthetic remodelling


The Journal of Bone & Joint Surgery British Volume
Vol. 86-B, Issue 1 | Pages 20 - 26
1 Jan 2004
Brodner W Bitzan P Lomoschitz F Krepler P Jankovsky R Lehr S Kainberger F Gottsauner-Wolf F

We investigated prospectively the bone mineral density (BMD) of the proximal femur after implantation of a tapered rectangular cementless stem in 100 patients with a mean age of 60 years (16 to 87). It was determined using dual energy x-ray absorptiometry, performed one week after surgery and then every six months until the end-point of five years. The BMD increased significantly in Gruen zones 2, 4 and 5 by 11%, 3% and 11% respectively, and decreased significantly in Gruen zones 1, 6 and 7 by 3%, 6% and 14% respectively, over the five-year period. The net mean BMD did not change over this time period. The changes in the BMD were not confined to the first 12 months after surgery. This investigation revealed no change in the overall periprosthetic BMD, but demonstrated a regional redistribution of bone mass from the proximal to distal zones


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XLI | Pages 118 - 118
1 Sep 2012
Bentley J
Full Access

Orthopaedic surgeons are astounded with the strength of bone found in Polynesians. Furthermore the rate at which new Polynesian bone over-grows metal fixation of a recent fracture is impressive. Studies demonstrate that Polynesians have a higher Bone Mineral Density (BMD) than age and weight matched Europeans in NZ (1, 2). In addition, Polynesians have a lower incidence of hip fractures when compared to other ethnic groups (3). This suggests that the higher BMD or other inherent differences must account for the lower incidence of hip fractures in Polynesians. The aim of this study was to identify (if any) a difference in osteoblast mitosis between European and Polynesian bone. Samples were collected from 13 patients that had joint replacements in accordance with the MCNZ ethics approval. The bone is processed and osteoblasts cultured in the lab to 50% confluence. The cells are then tagged with Propidium Iodide. Using Fluorescence-Activated Cell Sorting (or FACS) the number of osteoblasts in the different phases of the cell cycle are counted. The percentage of cells in G0/G1, S and G2/M phase can be determined by entering the FACS data into a program called mod-fit. This study shows that Polynesians have a greater proportion of cells undergoing replication (i.e S-phase) than their European counterparts. Incidentally we have also shown that the proportion of cells undergoing mitosis lowers with age irrespective of ethnicity


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_6 | Pages 4 - 4
1 Apr 2018
Baetz J Messer P Lampe F Pueschel K Klein A Morlock M Campbell G
Full Access

INTRODUCTION. Loosening is a major cause for revision in uncemented hip prostheses due to insufficient primary stability. Primary stability after surgery is achieved through press-fit in an undersized cavity. Cavity preparation is performed either by extraction (removing bone) or compaction (crushing bone) broaching. Densification of trabecular bone has been shown to enhance primary stability in human femora; however, the effect of clinically used compaction and extraction broaches on human bone with varying bone mineral density (BMD) has not yet been quantified. The purpose of this study was to determine the influence of the broach design and BMD on the level of densification at the bone-cavity interface, stem seating, the bone-implant contact area and the press-fit achieved. METHODS. Paired human femora (m/f=11/12, age=60±18 y) were scanned with quantitative computed tomography (QCT, Philips Brilliance 16) before broaching, with the final broach, after its removal and after stem implantation. Compaction broaching (n=4) was compared in an in situ (cadaver) study against extraction broaching with blunt tooth types (n=3); in an ex situ (excised femora) study, compaction broaching was compared against extraction broaching with sharp tooth types (n=8 each). QCT data were resampled to voxel sizes of 1×1×1 mm (in situ) and 0.5×0.5×1 mm (ex situ). Mean trabecular BMD of the proximal femur was determined. The cavity volumes were segmented in the post-broach images (threshold: −250 mgHA/cm3, Avizo 9.2) and a volume of interest (VOI) of one-voxel thickness was added around the cavity to capture the interfacial bone. VOIs were transferred to the pre-broach image and bone densification was calculated within each VOI as the increase from pre- to post-broach image (MATLAB). Detailed surface data sets of broaches and stems were collected with a 3D laser-scanner (Creaform Handyscan 700) and aligned with the segmented components in the CT scans (Fig. 1). Stem seating was defined as the difference between the top edge of the stem coating and the final broach. Distance maps between the stem and cavity surface were generated to determine the bone-implant contact area and press-fit. All parameters were analysed between 5 mm distal to the coating and 1 cm distal to the lesser trochanter and analysed with related-samples Wilcoxon signed rank and Spearman's correlation tests (IBM SPSS Statistics 22). RESULTS. Trabecular BMD ranged from 81 to 221 mgHA/cm3. Densification was higher with compaction compared to sharp (p=0.034), but not blunt extraction broaching (p=1.000). Proximal bone-implant contact area, press-fit and stem seating did not differ between broaching methods. Bone-implant contact area and bone densification increased with trabecular BMD (rs=0.658, p=0.001 and rs=0.443, p=0.034), press-fit with stem seating (rs=0.746, p<0.001) and contact area with bone densification (rs=0.432, p=0.039). DISCUSSION. Sharp extraction broaching reduces densification at the bone-cavity interface, but does not affect the press-fit or contact area. Trabecular BMD was positively associated with contact area, and stem seating with press-fit. Future studies will aim to link these findings to primary stability and influence on periprosthetic fractures. For any figures or tables, please contact authors directly


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_1 | Pages 4 - 4
1 Jan 2016
Todo M Abdullah AH Nakashima Y Iwamoto Y
Full Access

Bone remodeling effects is a significant issue in predicting long term stability of hip arthroplasty. It has been frequently observed around the femoral components especially with the implantation of prosthesis stem. Presence of the stiffer materials into the femur has altering the stress distribution and induces changes in the architecture of the bone. Phenomenon of bone resorption and bone thickening are the common reaction in total hip arthroplasty (THA) which leading to stem loosening and instability. The objectives of this study are (i) to develop inhomogeneous model of lower limbs with hip osteoarthritis and THA and (ii) to predict the bone resorption behavior of lower limbs for both cases. Biomechanical evaluations of lower limbs are established using the finite element method in predicting bone remodeling process. Lower limbs CT-based data of 79 years old female with hip osteoarthritis (OA) are used in constructing three dimensional inhomogenous models. The FE model of lower limbs was consisted of sacrum, left and right ilium and both femur shaft. Bond between cartilage, acetabulum and femoral head, sacrum and ilium were assumed to be rigidly connected. The inhomogeneous material properties of the bone are determined from the Hounsfield unit of the CT image using commercial biomedical software. A load case of 60kg body weight was considered and fixed at the distal cut of femoral shaft. For THA lower limbs model, the left femur which suffering for hip OA was cut off and implanted with prosthesis stem. THA implant is designed to be Titanium alloy and Alumina for stem and femoral ball, respectively. Distribution of young modulus of cross-sectional inhomogeneous model is presented in Fig. 2 while model of THA lower limbs also shown in Fig. 2. Higher values of young modulus at the outer part indicate hard or cortical bone. Prediction of bone resorption is discussed with the respect of bone mineral density (BMD). Changes in BMD at initial age to 5 years projection were simulated for hip OA and THA lower limbs models. The results show different pattern of stress distribution and bone mineral density between hip OA lower limbs and THA lower limbs. Stress is defined to be dominant at prosthesis stem while femur experienced less stress and leading to bone resorption. Projection for 5 years follow up shows that the density around the greater tronchanter appears to decrease significantly


The Journal of Bone & Joint Surgery British Volume
Vol. 86-B, Issue 2 | Pages 185 - 189
1 Mar 2004
Kishida Y Sugano N Nishii T Miki H Yamaguchi K Yoshikawa H

We investigated the effect of the Birmingham hip resurfacing (BHR) arthroplasty on the bone mineral density (BMD) of the femur. A comparative study was carried out on 26 hips in 25 patients. Group A consisted of 13 patients (13 hips) who had undergone resurfacing hip arthroplasty with the BHR system and group B of 12 patients (13 hips) who had had cementless total hip arthroplasty with a proximal circumferential plasma-spray titanium-coated anatomic Ti6A14V stem. Patients were matched for gender, state of disease and age at the time of surgery. The periprosthetic BMD of the femur was measured using dual-energy x-ray absorptiomentry of the Gruen zones at two years in patients in groups A and B. The median values of the BMD in zones 1 and 7 were 99% and 111%, respectively. The post-operative loss of the BMD in the proximal femur was significantly greater in group B than in group A. These findings show that the BHR system preserves the bone stock of the proximal femur after surgery


The Journal of Bone & Joint Surgery British Volume
Vol. 85-B, Issue 4 | Pages 611 - 617
1 May 2003
Tingart MJ Apreleva M von Stechow D Zurakowski D Warner JJP

The operative treatment of fractures of the proximal humerus can be complicated by poor bone quality. Our aim was to evaluate a new method which allows prediction of the bone quality of the proximal humerus from radiographs. Anteroposterior radiographs were taken of 19 human cadaver humeri. The cortical thickness was measured at two levels of the proximal humeral diaphysis. The bone mineral density (BMD) was determined for the humeral head (HH), the surgical neck (SN), the greater tuberosity (GT) and lesser tuberosity (LT) using dual-energy x-ray absorptiometry. The mean cortical thickness was 4.4 ± 1.0 mm. Specimens aged 70 years or less had a significantly higher cortical thickness than those aged over 70 years. A significant positive correlation was found between cortical thickness and the BMD for each region of interest. The cortical thickness of the proximal diaphysis is a reliable predictor of the bone quality of the proximal humerus


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_1 | Pages 125 - 125
1 Jan 2017
Anitha D Subburaj K Kirschke J Baum T
Full Access

Multiple myeloma (MM) is a chronic, malignant B-cell disorder, with a less than 50% 5-year survival rate [1]. This disease is responsible for vertebral compression fractures (VCFs) in 34 to 64% of diagnosed patients [1], and at least 80% of MM patients experience pathological fractures [3]. Even though reduced DXA-derived bone mineral density (BMD) has been observed in MM patients with vertebral fractures [4], the current quantitative standard method is insufficient in MM due to the osteo-destructive bone changes. Finite-element (FE) analysis is a computational and non-destructive modeling and testing approach to determine bone strength using 3D bone models from CT images. Thus, this study aimed to assess the differences in FE-predicted critical fracture load in MM patients with and without VCFs in the thoracic and lumbar segments of the spine. Multi-detector CT (MDCT) images of two radiologically assessed MM patients (1 with VCFs and 1 without VCFs) were used to generate three-dimensional (3D) models of the whole spine. For each subject, the thoracic segments, 1 to 12 (T1-T12) and lumbar segments, 1 to 5 (L1-L5) were segmented and meshed. Heterogeneous, non-linear anisotropic material properties were applied by discretizing each vertebral segment into 10 distinct sets of materials. A compressive load was simulated by constraining the surface nodes on the inferior endplate in all directions, and a displacement load was applied on the surface nods on the superior endplate [2]. This analysis was performed using ABAQUS version 6.10 (Hibbitt, Karlsson, and Sorensen, Inc., Pawtucket, RI, USA). The MM subject with VCFs had originally experienced fractures in the T4, T5, T12, L1, and L5 segments whereas the MM subject without VCFs experienced none. The former displayed large and abrupt differences in fracture loads between adjacent vertebrae segments, unlike the latter, which exhibited progressive differences instead (no abrupt changes between adjacent vertebrae segments observed). Results from this preliminary study suggest that segments at high risk of fracture are collectively involved in an unstable network, which place the vertebral segments with high values of fracture loads (peaks) as well as the adjacent segments at risk of VCF. For instance, the high fracture load at T11 places T10, T11 and T12 at risk of fracture. Accordingly, T12 has already fractured, and T10 and T11 remain at risk. The relative changes between adjacent vertebrae segments that indicate instability (extremely high fracture load values) enables ease of identification of segments at high fracture risk. Clinicians would be able to work with pre-emptive treatment strategies in future as they can focus on more targeted therapy options at the high-risk vertebrae segments [3]