Results 1 - 95 of 95
Results per page:
Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_16 | Pages 20 - 20
1 Dec 2021
Yang I Gammell JD Murray DW Mellon SJ
Full Access

Abstract. Background. The Oxford Domed Lateral (ODL) Unicompartmental Knee Replacement (UKR) has some advantages over other lateral UKRs, but the mobile bearing dislocation rate is high (1–6%). Medial dislocations, with the bearing lodged on the tibial component wall, are most common. Anterior/posterior dislocations are rare. For a dislocation to occur distraction of the joint is required. We have developed and validated a dislocation analysis tool based on a computer model of the ODL with a robotics path-planning algorithm to determine the Vertical Distraction required for a Dislocation (VDD), which is inversely related to the risk of dislocation. Objectives. To modify the ODL design so the risk of medial dislocation decreases to that of an anterior/posterior dislocation. Methods. The components were modified using Solidworks. For each modification the dislocation analysis tool was used to determine the VDD for medial dislocation (with bearing 0–6mm from the tibial wall). This was compared with the original implant to identify the modifications that were most effective at reducing the dislocation risk. These modifications were combined into a final design, which was assessed. Results. Modifying the tibial component plateau, changing the femoral component width and making the bearing wider medially had little effect on VDD. Shifting the femoral sphere centre medially decreased VDD. Shifting the femoral sphere laterally, increasing tibial wall height and increasing bearing width laterally increased VDD. A modified implant with a femoral sphere centre 3mm lateral, wall 2.8mm higher, and bearing 2mm wider laterally, implanted so the bearing is ≤4mm from the tibial wall with a bearing thickness ≥4mm had a minimum VDD for medial dislocation of 5.75mm, which is larger than the minimum VDD for anterior/posterior dislocation of 5.5mm. Conclusions. A modified ODL design should decrease the dislocation rate to an acceptable level, however, further testing in cadavers is required. Declaration of Interest. (a) fully declare any financial or other potential conflict of interest


The Bone & Joint Journal
Vol. 106-B, Issue 9 | Pages 916 - 923
1 Sep 2024
Fricka KB Wilson EJ Strait AV Ho H Hopper, Jr RH Hamilton WG Sershon RA

Aims. The optimal bearing surface design for medial unicompartmental knee arthroplasty (UKA) remains controversial. The aim of this study was to compare outcomes of fixed-bearing (FB) and mobile-bearing (MB) UKAs from a single high-volume institution. Methods. Prospectively collected data were reviewed for all primary cemented medial UKAs performed by seven surgeons from January 2006 to December 2022. A total of 2,999 UKAs were identified, including 2,315 FB and 684 MB cases. The primary outcome measure was implant survival. Secondary outcomes included 90-day and cumulative complications, reoperations, component revisions, conversion arthroplasties, range of motion, and patient-reported outcome measures. Overall mean age at surgery was 65.7 years (32.9 to 94.3), 53.1% (1,593/2,999) of UKAs were implanted in female patients, and demographics between groups were similar (p > 0.05). The mean follow-up for all UKAs was 3.7 years (0.0 to 15.6). Results. Using revision for any reason as an endpoint, five-year survival for FB UKAs was 97.2% (95% CI 96.4 to 98.1) compared to 96.0% for MB (95% CI 94.1 to 97.9; p = 0.008). The FB group experienced fewer component revisions (14/2,315, 0.6% vs 12/684, 1.8%; p < 0.001) and conversion arthroplasties (38/2315, 1.6% vs 24/684, 3.5%; p < 0.001). A greater number of MB UKAs underwent revision due to osteoarthritis progression (FB = 21/2,315, 0.9% vs MB = 16/684, 2.3%; p = 0.003). In the MB group, 12 (1.8%) subjects experienced bearing dislocations which required revision surgery. There were 15 early periprosthetic tibia fractures (0.6%) in the FB group compared to 0 for MB (p = 0.035). Conclusion. In similar patient populations, FB UKAs demonstrated slightly higher survival than a commonly used MB design. Adverse event profiles differed by bearing type, with an increased risk of bearing dislocation and OA progression with MB designs, and early periprosthetic tibia fractures for FB designs. Cite this article: Bone Joint J 2024;106-B(9):916–923


The Bone & Joint Journal
Vol. 105-B, Issue 3 | Pages 269 - 276
1 Mar 2023
Tay ML Monk AP Frampton CM Hooper GJ Young SW

Aims. Unicompartmental knee arthroplasty (UKA) has higher revision rates than total knee arthroplasty (TKA). As revision of UKA may be less technically demanding than revision TKA, UKA patients with poor functional outcomes may be more likely to be offered revision than TKA patients with similar outcomes. The aim of this study was to compare clinical thresholds for revisions between TKA and UKA using revision incidence and patient-reported outcomes, in a large, matched cohort at early, mid-, and late-term follow-up. Methods. Analyses were performed on propensity score-matched patient cohorts of TKAs and UKAs (2:1) registered in the New Zealand Joint Registry between 1 January 1999 and 31 December 2019 with an Oxford Knee Score (OKS) response at six months (n, TKA: 16,774; UKA: 8,387), five years (TKA: 6,718; UKA: 3,359), or ten years (TKA: 3,486; UKA: 1,743). Associations between OKS and revision within two years following the score were examined. Thresholds were compared using receiver operating characteristic analysis. Reasons for aseptic revision were compared using cumulative incidence with competing risk. Results. Fewer TKA patients with ‘poor’ outcomes (≤ 25) subsequently underwent revision compared with UKA at six months (5.1% vs 19.6%; p < 0.001), five years (4.3% vs 12.5%; p < 0.001), and ten years (6.4% vs 15.0%; p = 0.024). Compared with TKA, the relative risk for UKA was 2.5-times higher for ‘unknown’ reasons, bearing dislocations, and disease progression. Conclusion. Compared with TKA, more UKA patients with poor outcomes underwent revision from early to long-term follow-up, and were more likely to undergo revision for ‘unknown’ reasons, which suggest a lower clinical threshold for UKA. For UKA, revision risk was higher for bearing dislocations and disease progression. There is supporting evidence that the higher revision UKA rates are associated with lower clinical thresholds for revision and additional modes of failure. Cite this article: Bone Joint J 2023;105-B(3):269–276


Bone & Joint Open
Vol. 4, Issue 6 | Pages 457 - 462
26 Jun 2023
Bredgaard Jensen C Gromov K Petersen PB Jørgensen CC Kehlet H Troelsen A

Aims. Medial unicompartmental knee arthroplasty (mUKA) is an advised treatment for anteromedial knee osteoarthritis. While long-term survival after mUKA is well described, reported incidences of short-term surgical complications vary and the effect of surgical usage on complications is less established. We aimed to describe the overall occurrence and treatment of surgical complications within 90 days of mUKA, as well as occurrence in high-usage centres compared to low-usage centres. Methods. mUKAs performed in eight fast-track centres from February 2010 to June 2018 were included from the Lundbeck Foundation Centre for Fast-track Hip and Knee Replacement Database. All readmissions within 90 days of surgery underwent chart review and readmissions related to the surgical wound or the prosthesis were recorded. Centres were categorized as high-usage centres when using mUKA in ≥ 20% of annual knee arthroplasties. The occurrence of complications between high- and low-usage centres were compared using Fisher’s exact test. Results. We included 3,757 mUKAs: 2,377 mUKAs from high-usage centres and 1,380 mUKAs from low-usage centres. Surgical complications within 90 days occurred in 69 cases (1.8%), 45 (1.9%) in high-usage centres and 24 (1.7%) in low-usage centres (odds ratio (OR) 1.1 (95% confidence interval (CI) 0.65 to 1.8)). The most frequent complications were periprosthetic joint infections (PJIs) (n = 18; 0.48%), wound-related issues (n = 14; 0.37%), and periprosthetic fractures (n = 13; 0.35%). Bearing dislocations (n = 7; 0.19%) occurred primarily in procedures from high-usage centres. In high-usage centres, seven periprosthetic fractures (0.29%) occurred compared to six (0.43%) in low-usage centres (OR 0.68 (95% CI 0.20 to 2.0)). In high-usage centres, nine PJIs (0.38%) occurred compared to nine (0.65%) in low-usage centres (OR 0.58 (95% CI 0.22 to 1.6)). Conclusion. Surgical complications are rare after fast-track mUKA surgery and with no difference in overall occurrence of surgical complications between high- and low-usage centres, although the risk of some specific surgical complications may favour high-usage centres. Cite this article: Bone Jt Open 2023;4(6):457–462


Orthopaedic Proceedings
Vol. 85-B, Issue SUPP_I | Pages 64 - 64
1 Jan 2003
Lee PTH Clarke MT Villar RNV
Full Access

Background: Metal-on-metal (MOM) bearing surfaces with low diametric clearance possess a surface tension that prevents easy separation of the surfaces when lubricated. Potentially this ‘suction-fit’ may increase the torque required for dislocation. This study assessed the protective role of a MOM bearing surface as a single risk factor for dislocation.

Method: Prospective data was recorded on a series of 229 patients undergoing 249 primary THR for osteoarthritis. From 1993–8, patients under 70 years old were routinely given a 28mm ceramic-on-polyethylene (COP) bearing surface. Due to a high dislocation rate (see results below), an alternative was sought (1998–2001) and a 28mm metal-on-metal (MOM) bearing system chosen. For all cases in both groups, the acetabulum was uncemented with a modular 10° posterior lip insert allowing the same primary arc range (Duraloc/PFC/ Ultima, Johnson & Johnson). The cemented femoral component was the same in all cases (Ultima). All operations were performed by the same surgeon using the posterior approach. Variables in patient and prosthesis factors were compared. Statistical analysis was performed by the Chi-square and student’s t-test where appropriate.

Results: We identified 140 THR in 129 patients who received a COP bearing and 109 THR in 100 patients who received a MOM bearing. Nine of 140 (6.4%) COP bearings dislocated within 3 months of surgery compared to 1 of 109 (0.9%) in the MOM group (p=0.028). No significant differences were identified between groups when comparing factors relating to the patient or prosthesis.

Discussion: This study has shown a high dislocation rate for a COP bearing that was reduced to a low dislocation rate by changing the bearing surface to a MOM design. A potential mechanism for this may be the ‘suction fit’ from the surface tension of the low clearance, high tolerance that the metal-on-metal bearing possesses, requiring increased torque to dislocate during impingement.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_3 | Pages 16 - 16
23 Feb 2023
Tay M Bolam S Coleman B Munro J Monk A Hooper G Young S
Full Access

Source of the study: University of Auckland, Auckland, New Zealand. Unicompartmental knee arthroplasty (UKA) is effective for patients with isolated compartment osteoarthritis, however the procedure has higher revision rates. Long-term survivorship and accurate characterisation of revision reasons are limited by a lack of long-term data and standardised revision definitions. We aimed to identify survivorship, risk factors and revision reasons in a large UKA cohort with up to 20 years follow-up. Patient, implant and revision details were recorded through clinical and radiological review for 2,137 consecutive patients undergoing primary medial UKA across Auckland, Canterbury, Counties Manukau and Waitematā DHB between 2000 and 2017. Revision reasons were determined from review of clinical, laboratory, and radiological records for each patient using a standardised protocol. To ensure complete follow-up data was cross-referenced with the New Zealand Joint Registry to identify patients undergoing subsequent revision outside the hospitals. Implant survival, revision risk and revision reasons were analysed using Cox proportional-hazards and competing risk analyses. Implant survivorship at 15 years was comparable for cemented fixed-bearing (cemFB; 91%) and uncemented mobile-bearing (uncemMB; 91%), but lower for cemented mobile-bearing (cemMB; 80%) implants. There was higher incidence of aseptic loosening with cemented implants (3–4% vs. 0.4% uncemented, p<0.01), osteoarthritis (OA) progression with cemMB implants (9% vs. 3% cemFB/uncemMB; p<0.05) and bearing dislocations with uncemMB implants (3% vs. 2% cemMB, p=0.02). Compared with the oldest patients (≥75 years), there was a nearly two-fold increase in risk for those aged 55–64 (hazard ratio 1.9; confidence interval 1.1-3.3, p=0.03). No association was found with gender, BMI or ASA. Cemented mobile-bearing implants and younger age were linked to lower implant survivorship. These were associated with disease progression and bearing dislocations. The use of cemented fixed-bearing and uncemented mobile-bearing designs have superior comparable long-term survivorship


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_2 | Pages 95 - 95
10 Feb 2023
Mowbray J Frampton C Maxwell R Hooper G
Full Access

Cementless fixation is an alternative to cemented unicompartmental knee replacement (UKR), with several advantages over cementation. This study reports on the 15-year survival and 10-year clinical outcomes of the cementless Oxford unicompartmental knee replacement (OUKR). This prospective study describes the clinical outcomes and survival of first 693 consecutive cementless medial OUKRs implanted in New Zealand. The sixteen-year survival was 89.2%, with forty-six knees being revised. The commonest reason for revision was progression of arthritis, which occurred in twenty-three knees, followed by primary dislocation of the bearing, which occurred in nine knees. There were two bearing dislocations secondary to trauma and a ruptured ACL, and two tibial plateau fractures. There were four revisions for polyethylene wear. There were four revisions for aseptic tibial loosening, and one revision for impingement secondary to overhang of the tibial component. There was only one revision for deep infection and one revision where the indication was not stated. The mean OKS improved from 23.3 (7.4 SD) to 40.59 (SD 6.8) at a mean follow-up of sixteen years. In conclusion, the cementless OUKR is a safe and reproducible procedure with excellent sixteen-year survival and clinical outcomes


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_3 | Pages 14 - 14
23 Feb 2023
Tay M Monk A Frampton C Hooper G Young S
Full Access

Source of the study: University of Auckland, Auckland, New Zealand and University of Otago, Christchurch, New Zealand. Patient reported outcome measures (PROMs) are predictors of knee arthroplasty revision. Unicompartmental knee arthroplasty (UKA) is effective for patients with the correct indications, however has higher revision rates than total knee arthroplasty (TKA). Different revision thresholds for the procedures have been postulated. Our aims were to investigate: 1) if PROMs could predict knee arthroplasty revision within two years of the score at six months, five years and ten years follow-up, and 2) if revision ‘thresholds’ differed between TKA and UKA. All TKAs and UKAs captured by the New Zealand Joint Registry between 1999 and 2019 with at least one OKS response at six months (TKA n=27,708, UKA n=8,415), five years (TKA n=11,519, UKA n=3,365) or ten years (TKA n=6,311, UKA n=1,744) were included. were propensity-score matched 2:1 with UKAs for comparison of revision thresholds. Logistic regression indicated that for every one-unit decrease in OKS, the odds of TKA and UKA revision decreased by 10% and 11% at six months, 10% and 12% at five years and 9% and 5% at ten years. Fewer TKA patients with ‘poor’ outcomes (≤25) subsequently underwent revision compared with UKA at six months (5.1% vs. 19.6%, p<0.001), five years (4.3% vs. 12.5%, p<0.001) and ten years (6.4%vs. 15.0%, p=0.02). Compared with TKA, UKA patients were 2.5 times more likely to undergo revision for ‘unknown’ reasons, bearing dislocations and disease progression. The OKS is a strong predictor of subsequent knee arthroplasty revision within two years of the score from early to late term. A lower revision threshold was found with UKA when compared with a matched TKA cohort. Higher revision rates of UKA are associated with both lower clinical thresholds for revision and additional modes of UKA failure


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_II | Pages 210 - 210
1 May 2011
Simpson D Kendrick B O’Connor J Pandit H Dodd C Murray D
Full Access

Introduction: The results of the mobile bearing Oxford partial knee replacement (PKR) in the lateral compartment have been disappointing with a five year survival of 82%. Bearing dislocation is a particular concern, and to address this issue a new domed implant was introduced with a modified surgical technique. The aim of this study was to compare the risk of dislocation between a domed and flat lateral PKR. Methods: Separate kinematic models were generated for the domed and flat bearings. The femoral component, tibial tray and bearing were aligned in a neutral position; the flat bearing was positioned centrally on the tibial tray and 2 mm from the side wall; the domed bearing was placed concentrically on the domed tibial tray. Dislocation in the Posterior (A-P), Lateral (M-L) and Medial against the tray wall (L-M-wall) were investigated. For each dislocation the tibial tray was restrained in all degrees of freedom (DOF) and the femoral component was restrained in five DOF; A-P and M-L displacements; A-P, M-L and Superior-Inferior (S-I) rotations. The bearing was restrained from rotating about the S-I axis for each dislocation. For the L-M-wall dislocation the underside of the bearing was held in contact with the tibial tray wall such that the lowest S-I displacement of the femoral component was achieved. The least amount of distraction required for bearing dislocation to occur was calculated for the seven bearing sizes available. The effect of medial-lateral positioning of the femur on dislocation was investigated. Results: The minimum femur distraction to cause A-P flat and domed bearing dislocation ranged from 4.68mm to 3.91mm and 6.29mm to 5.59mm respectively as the bearing thickness increased from 3.5mm to 9.5mm. The minimum femur distraction to cause L-M-wall flat and domed bearing dislocation ranged from 3.42mm to 4.16mm and 4.55mm to 5.44mm respectively as the bearing thickness increased from 3.5 mm to 9.5 mm. The femur distraction required for L-M-wall bearing dislocation increased from 4.55mm to 6.3mm with a 2 mm medial movement of the femoral component. A 4 mm lateral movement of the femoral component decreased the distraction from 4.55mm to 2.35mm. Discussion: A domed bearing can lead to an increased femoral distraction of between 25% and 37%, significantly reducing the likelihood of dislocation. This may be significant during everyday activities and demonstrates that the new domed design should reduce the incidence of bearing dislocation by increasing the amount of entrapment; our current series of 200 patients has no dislocations. Increasing the thickness of the bearing has a small effect on the distraction required to allow bearing dislocation. The medial-lateral placement of the femoral component has a pronounced effect on the femoral distraction required for bearing dislocation over the tray wall; medial placement of the femoral component is advisable


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_16 | Pages 19 - 19
1 Oct 2017
Masud S Guro R Mohan R Chandratreya A
Full Access

Oxford Medial Unicompartmental Knee Replacement (OMUKR) is a well-established treatment option for isolated medial compartment arthritis, with good patient reported outcome measures (PROMs). We present our results of the Oxford Domed Lateral Unicompartmental Knee Replacement (ODLUKR) to establish if patients benefit as much as with OMUKR. Retrospective review of prospectively collected data of a single surgeon series of consecutive UKR from 2007 to 2014 were collated with a minimum 2 years follow-up. PROMs data were collected using pre- and post-operative Oxford Knee Scores (OKS) (best score of 48). One hundred and twenty-eight OMUKR and 27 ODLUKR were performed in the study period. There was no significant difference in the age at time of surgery, but there were significantly more women in the ODLUKR group (74% vs 53%). There was no significant difference in pre-op OKS between the groups (OMUKR = 16/48; ODLUKR = 20/48), or the improvement in OKS post-op (OMUKR = 19 points; ODLUKR = 17 points). One ODLUKR was revised to Total Knee Replacement (TKR) for pain. There were three (11.1%) bearing dislocations, which were treated with thicker bearing exchange, with no subsequent problems. There were no bearing dislocations in the OMUKR. Four OMUKR were revised to TKR due to pain. The overall implant survivorship was 96.3% for ODLUKR and 96.9% for OMUKR. ODLUKR is a good treatment option for isolated lateral compartment arthritis and gives results equivalent to OMUKR. There is, however, an increased risk of bearing dislocation so should be performed by a high volume UKR surgeon


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XVIII | Pages 59 - 59
1 May 2012
Simpson DJ Kendrick B Thomas G Gill H O'Connor J Murray DW
Full Access

Introduction. The results of the original mobile bearing Oxford unicompartmental knee replacement (UKR) in the lateral compartment have been disappointing because of high dislocation rates (11%). This original implant used a flat bearing articulation on the tibial tray. To address the issue of dislocation a new implant (domed tibia with biconcave bearing to increase entrapment) was introduced with a modified surgical technique. The aim of this study was to compare the risk of dislocation between a domed and flat lateral UKR. Methods. Separate geometric computer models of an Oxford mobile bearing lateral UKR were generated for the two types of articulation between the tibial component and the meniscal bearing: Flat-on-flat (flat) and Concave-on-convex (domed). Each type of mobile bearing was used to investigate three distinct dislocation modes observed clinically: lateral to medial dislocation, with the bearing resting on the tray wall (L-M-Wall); medial to lateral dislocation, out of the joint space (M-L); anterior to posterior dislocation, out of the joint space (A-P). A size C tray and a medium femoral component and bearing were used in all models. The femoral component, tibial tray and bearing were first aligned in a neutral position. For each dislocation the tibial tray was restrained in all degrees of freedom. The femoral component was restrained from moving in the anterior-posterior directions and in the medial-lateral directions. The femoral component was also restrained from rotating about the anterior-posterior, medial-lateral and superior-inferior directions. This meant that the femoral component was only able to move in the superior-inferior direction. Different bearing sizes were inserted into the model and the effect that moving the femoral component medially and laterally had on the amount of distraction required to cause bearing dislocation was investigated. Results. The average femur distraction to allow bearing dislocation in the A-P, M-L and L-M-wall directions was 1.62 mm (27%), 0.51 mm (26%) and 1.2 mm (24%) greater respectively for the domed bearing. There was a 3% increase in femoral distraction required to cause L-M-Wall dislocation, per increment of bearing thickness for both the domed and lateral bearings. There was on average a 7% increase in femoral distraction required to cause L-M-Wall dislocation per mm increment of medial femoral component movement. Discussion. Dislocation over the tray wall is a particular clinical problem and using a domed bearing can lead to an increased required femoral distraction of between 25% and 37%. This may be significant during everyday activities and demonstrates that the new domed design should reduce the incidence of bearing dislocation by increasing the amount of entrapment. Increasing the thickness of the bearing has a small effect on the distraction required to allow bearing dislocation. Lateral placement of the femoral component markedly reduced the femoral distraction required for bearing dislocation over the tray wall. Medial placement of the femoral component is advisable so long as impingement with the tray wall is avoided


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_4 | Pages 69 - 69
1 Feb 2017
Kim K Lee S
Full Access

Background. To evaluate the causes and modes of complications after unicompartmental knee arthroplasty (UKA), and to identify its prevention and treatment method by analyzing the complications after UKA. Materials and Methods. A total of 1,576 UKAs were performed between January 2002 and December 2014 at a single-institution. Postoperative complications occurred in 89 knees (83 patients, 5.6%), and 86 of them were found in females and 3 in males. Their mean age was 61 years (range, 46 to 81 years) at the time of initial UKA and 66 years (range, 46 to 82 years) at the time of revision surgery. We analyzed the complications after UKA retrospectively andinvestigated the proper methods of treatment (Table 1). Results. A total of 89 complications (5.6%) occurred afterUKA. Regarding the type of complications after UKA, there were bearing dislocation (n=42), component loosening (n=23), 11 cases of femoral component loosening, 8 cases of tibial component loosening, and 4 cases of both femoral and tibial component loosening, periprosthetic fracture (n=6), polyethylene wear/ destruction (n=3), progression of arthritis to the other compartment (n=3), medial collateral ligament (MCL) injury (n=2), impingement (n=2), infection (n=5), ankylosis (n=1), and unexplained pain (n=2) (Table 2). The most common complication after UKA was mobile bearing dislocation in mobile-bearing type and loosening of prosthesis in fixed-bearing type, but polyethylene wear and progression of arthritis were relatively rare. The mean interval from UKA to the occurrence of complications was 4 years and 6 months (range, 0 [during operation] to 12 years). Of those complications following UKA, 58 knees were treated with conversion TKA, 1 with revision UKA, and 21 with simple bearing change. Complications in the remaining knees were treated with arthroscopic management (n=2), open reduction and internal fixation (n=3), closed reduction and internal fixation (n=1), manipulation (n=1), and MCL repair (n=2) (Table 3). Discussion. In this single-center study, we reviewed the causes and types of complications (n=89) that occurred following UKA (n=1,576) and investigated optimal treatment methods. The incidence and type of complications were also compared among patients classified according to gender, medial/lateral UKA, and implant design and type. The strengths of this study include that all the patients were enrolled from the same institution and the sample size (UKA cases and complication cases) was relatively large compared to that in previous publications. The most common complication following UKA was bearing dislocation in the mobile-bearing knees and component loosening in the fixed-bearing knees. The incidence of polyethylene wear and progression of arthritis to the other compartment was relatively low. The results of our study are in some discrepancy with those of studies involving Western patients. This can be attributed to the differences in patient characteristics such as lifestyle and in the type and design of implant used. Conclusion. Thorough understanding of UKA, proper patient selection, appropriate implant choice are essential to reduce complications following UKA and obtain satisfactory outcomes. We suggest that complications following UKA should be treated differently according to the type and cause of complication and conversion TKA can be the most effective treatment when revision operation is determined necessary


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_6 | Pages 33 - 33
1 Apr 2018
Song M Kim Y Yoo S Kang S Kwack C
Full Access

Purpose. Unicompartmental Knee Arthroplasty (UKA) has been indicated for inactive elderly patients over 60, but for young and active patients less than 60 years old, it has been regarded as a contraindication. The purpose of this study is to evaluate the usefulness of UKA performed on young Asian patients under 60 years of age by analyzing clinical outcomes, complications and survival rate. Materials and Methods. The subjects were 82 cases, which were followed up for at least 5 years (from 5 to 12 years). Only Oxford phase III® (Biomet Orthopedics, Inc, Warsaw, USA) prosthesis was used for all cases. The clinical evaluation was done by the range of motion, Knee society score (KSS), WOMAC score. The radiographic evaluation was performed on weight bearing long-leg radiographs, AP and lateral view of the knee and skyline view of the patella. The survival rate was estimated by Kaplan-Meier survival analysis. Results. Three bearing dislocations, one medial tibial collapse and one lateral osteoarthritis occurred, so the complication rate was 6.1% (5/82). Among the 3 cases of bearing dislocation, 2 cases were resolved by replacing with a thicker bearing and 1 case was converted to TKA due to repeated dislocation. One case of medial tibia collapse and one lateral osteoarthritis were converted to total knee arthroplasty (TKA). All clinical outcomes measured by KSS scores and WOMAC score showed a statistically significant difference (p<0.001). The 10 year cumulative survival rate using Kaplan-Meier survival method was 94.7% (95% CI: 88.7%–100%). Conclusion. The clinical outcomes and the survival rate of young asian patients less than 60 years of age who underwent Oxford medial UKA showed good clinical results and a good survival rate in the mid-term results. However, long-term follow-up is needed for more reliable clinical results


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XII | Pages 5 - 5
1 Apr 2012
Wakeling C Bracey D
Full Access

The Oxford unicompartmental knee replacement (UKR) was introduced in 1976 with good results. Mobile bearings in the lateral compartment have been associated with unacceptably high bearing dislocation rates, due to greater movement between the lateral femoral condyle and tibia, and the lateral collateral ligament's laxity in flexion. The new domed implant is designed to counter this with a convex tibial prosthesis and a fully-congruent, bi-concave mobile bearing allowing a full range-of-movement (ROM), minimising dislocation risk and bearing wear. We present complication rates and clinical outcomes for a consecutive series of our first 20 patients undergoing Oxford domed lateral UKR, between June 2006 and August 2009, with minimum 6-month follow-up. There was one unrelated death (31 months post-UKR) and one postop MI. We had no bearing dislocations, infections or loosening nor other complications. All patients had post-op Oxford Knee Scores; eleven had pre-op scores and demonstrated a significant improvement – mean pre-op 22.75 to post-op 35.45 (p=0.01). All achieved full extension with average ROM 116°, mean change in ROM was –2.6°(p=0.6). This study adds to previous work in confirming a low level of complications with this new procedure (including the early learning curve), particularly bearing dislocation and demonstrates excellent functional outcomes


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_IX | Pages 25 - 25
1 Mar 2012
Pandit H Jenkins C Gill H Beard D Price A Dodd C Murray D
Full Access

Introduction. The results of the mobile bearing Oxford unicompartmental knee replacement (UKR) in the lateral compartment have been disappointing with a five year survival of 82%. Therefore, it is recommended that mobile bearings should not be used for lateral UKR. This low survivorship is primarily due to high dislocation rate, all occurring in the first year. A detailed analysis of the causes of bearing dislocation confirmed the elevated lateral tibial joint line to be a contributory factor. A new surgical technique was therefore introduced in which care was taken neither to remove too much bone from distal femur nor to over tighten the knee and thus ensure that the tibial joint line was not elevated. Other modifications to the technique were also introduced including use of a domed tibial component. Aim. The aim of this study is to compare the outcome of these iterations: the original series [series I], Series II with improved surgical technique and the domed tibial component [Series III]. Method. The primary assessment of outcome was bearing dislocation at one year. One year was chosen as all the dislocations in the first series occurred within a year. In series I, there were 53 knees, in series II 65 knees and in series III 100 knees, all with a minimum of one year follow up. Results. In series I, there were 6 bearing dislocations (11%) and the average range of movement (ROM) was 110°. In the second series, there were 2 dislocations (3%) and the average ROM was 118°. In the third series, there were no primary dislocations and the average ROM was 125°, the difference between range of movement as well as dislocation rate being significant. Conclusions. The improved surgical technique and implant design have reduced the dislocation rate to an acceptable level and therefore a mobile bearing can now be recommended for lateral UKR


Orthopaedic Proceedings
Vol. 91-B, Issue SUPP_III | Pages 412 - 412
1 Sep 2009
Pandit H Jenkins C Gill H Beard D Marks B Price A Dodd C Murray D
Full Access

Introduction: The results of the mobile bearing Oxford unicompartmental knee replacement (UKR) in the lateral compartment have been disappointing with a five year survival of 82%. Therefore, it is recommended that mobile bearings should not be used for lateral UKR. This low survivorship is primarily due to high dislocation rate, all occurring in the first year. A detailed analysis of the causes of bearing dislocation confirmed the elevated lateral tibial joint line to be a contributory factor. A new surgical technique was therefore introduced in which care was taken neither to remove too much bone from the distal femur nor to over tighten the knee and therefore ensure that the tibial joint line was not elevated. Other modifications to the technique were also introduced including use of a domed tibial component. Aim: The aim of this study is to compare the outcome of these iterations: the original series [series I], Series II with improved surgical technique and the domed tibial component [Series III]. Method: The primary assessment of outcome was bearing dislocation at one year. One year was chosen as all the dislocations in the first series occurred within a year. In series I, there were 53 knees, in series II 65 knees and in series III 60 knees, all with a minimum of one year follow up. Results: In series I, there were 6 bearing dislocations (11%) and the average range of movement (ROM) was 110°. In the second series, there were 2 dislocations (3%) and the average ROM was 118°. In the third series, there were no primary dislocations and the average ROM was 125°. Conclusions: The improved surgical technique and implant design has reduced the dislocation rate to an acceptable level so a mobile bearing can now be recommended for lateral UKR


The Bone & Joint Journal
Vol. 96-B, Issue 7 | Pages 914 - 922
1 Jul 2014
Lee SY Bae JH Kim JG Jang KM Shon WY Kim KW Lim HC

The aim of this study was to evaluate the risk factors for dislocation of the bearing after a mobile-bearing Oxford medial unicompartmental knee replacement (UKR) and to test the hypothesis that surgical factors, as measured from post-operative radiographs, are associated with its dislocation. From a total of 480 UKRs performed between 2001 and 2012, in 391 patients with a mean age of 66.5 years (45 to 82) (316 female, 75 male), we identified 17 UKRs where bearing dislocation occurred. The post-operative radiological measurements of the 17 UKRs and 51 matched controls were analysed using conditional logistic regression analysis. The post-operative radiological measurements included post-operative change in limb alignment, the position of the femoral and tibial components, the resection depth of the proximal tibia, and the femoral component-posterior condyle classification. We concluded that a post-operative decrease in the posterior tibial slope relative to the pre-operative value was the only significant determinant of dislocation of the bearing after medial Oxford UKR (odds ratio 1.881; 95% confidence interval 1.272 to 2.779). A post-operative posterior tibial slope < 8.45° and a difference between the pre-operative and post-operative posterior tibial slope of > 2.19° may increase the risk of dislocation. Cite this article: Bone Joint J 2014; 96-B:914–22


The Bone & Joint Journal
Vol. 98-B, Issue 10_Supple_B | Pages 22 - 27
1 Oct 2016
Bottomley N Jones LD Rout R Alvand A Rombach I Evans T Jackson WFM Beard DJ Price AJ

Aims. The aim of this to study was to compare the previously unreported long-term survival outcome of the Oxford medial unicompartmental knee arthroplasty (UKA) performed by trainee surgeons and consultants. . Patients and Methods. We therefore identified a previously unreported cohort of 1084 knees in 947 patients who had a UKA inserted for anteromedial knee arthritis by consultants and surgeons in training, at a tertiary arthroplasty centre and performed survival analysis on the group with revision as the endpoint. Results. The ten-year cumulative survival rate for revision or exchange of any part of the prosthetic components was 93.2% (95% confidence interval (CI) 86.1 to 100, number at risk 45). Consultant surgeons had a nine-year cumulative survival rate of 93.9% (95% CI 90.2 to 97.6, number at risk 16). Trainee surgeons had a cumulative nine-year survival rate of 93.0% (95% CI 90.3 to 95.7, number at risk 35). Although there was no differences in implant survival between consultants and trainees (p = 0.30), there was a difference in failure pattern whereby all re-operations performed for bearing dislocation (n = 7), occurred in the trainee group. This accounted for 0.6% of the entire cohort and 15% of the re-operations. . Conclusion. This is the largest single series of the Oxford UKA ever reported and demonstrates that good results can be achieved by a heterogeneous group of surgeons, including trainees, if performed within a high-volume centre with considerable experience with the procedure. Cite this article: Bone Joint J 2016;(10 Suppl B):22–7


Orthopaedic Proceedings
Vol. 86-B, Issue SUPP_I | Pages 18 - 18
1 Jan 2004
Robinson B Halliday S Price A Beard D Rees J Dodd C Murray D Goodfellow J O’Connor J
Full Access

When the Oxford unicompartmental meniscal bearing arthroplasty (UCA) is used in the lateral compartment of the knee 10% of the bearings dislocate. An in-vitro cadaveric study was performed to investigate if the anatomy and joint geometry of the lateral compartment was a contributory factor in bearing dislocation. More specifically, the study investigated if the soft tissue tension of the lateral compartment, as determined by the length of the lateral collateral ligament (LCL), was related to bearing dislocation. A change in length of greater than 2 mm is sufficient to allow the bearing to dislocate. The Vicon Motion Analysis System (Oxford Metrics, Oxford, UK) was used to assess length changes in the LCL of seven cadaveric knees. Measurements were made of the LCL length through knee flexion and of the change in LCL length when a varus force was applied at a fixed flexion angle. Measurements were made in the normal knee and with the knee implanted with the Oxford prosthesis. In the intact knee the mean LCL change was 5.5mm (8%) over the flexion range. After implantation with the Oxford UCA the mean change in length was only 1 mm (1%). There was a significant difference in the LCL length at 90° (p=0.03) and 135° (p=0.01) of knee flexion compared to the intact knee. When a varus force was applied the LCL length change of the intact knee (5.4 mm) was significantly different (p=0.02) to that of the knee with the prosthesis implanted (2.7 mm). This study used a new method to dynamically measure LCL length. It found that after implantation of the Oxford lateral UCA the LCL remains isometric over the flexion range and does not slacken in flexion as it in the normal knee. This would suggest that the soft tissue tension was adequate to contain the bearing within the joint. However, when a varus force was applied the LCL did not sufficiently resist a displacing force producing an LCL length change greater than 2 mm. The evidence provided by this study is contradictory. The “lack of change in LCL length through flexion” suggests that the ligament remains tight through range and is unlikely to allow dislocation. However, the amount of distraction possible when an adducting moment is applied is sufficient to allow bearing dislocation. The length tension properties of the lateral structures are therefore implicated in the mechanism of dislocation


Bone & Joint Open
Vol. 4, Issue 12 | Pages 923 - 931
4 Dec 2023
Mikkelsen M Rasmussen LE Price A Pedersen AB Gromov K Troelsen A

Aims

The aim of this study was to describe the pattern of revision indications for unicompartmental knee arthroplasty (UKA) and total knee arthroplasty (TKA) and any change to this pattern for UKA patients over the last 20 years, and to investigate potential associations to changes in surgical practice over time.

Methods

All primary knee arthroplasty surgeries performed due to primary osteoarthritis and their revisions reported to the Danish Knee Arthroplasty Register from 1997 to 2017 were included. Complex surgeries were excluded. The data was linked to the National Patient Register and the Civil Registration System for comorbidity, mortality, and emigration status. TKAs were propensity score matched 4:1 to UKAs. Revision risks were compared using competing risk Cox proportional hazard regression with a shared γ frailty component.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXI | Pages 118 - 118
1 May 2012
T P J R J M A P M H
Full Access

Background. A commonly held belief amongst surgeons and patients is that progression of disease (arthritis) to other compartments is a major cause of early failure of UKRs. Methods. We analysed the NJR database records of 17,643 primary UKRs performed between April 2003 and April 2009. Where these had been revised the reason for revision was noted. Results. Of the 17,643 primary UKRs, 308 had died and were excluded from the analysis. Of the living, 505 had been revised (3%) at a mean 3.45 years (range 2-6 years) following the primary procedure. Reason for revision was recorded in 472 cases (93%). Aseptic loosening was the commonest cause for revision in 154 cases (33%), followed by non specific pain in 129 cases (27%), bearing dislocation in 58 cases (12%), Instability in 33 cases (7%), Infection 28 cases (6%), progression of disease 23 cases (5%), periprosthetic fracture 19 cases (4%) and malalignment 15 cases (3%). 35% failed within 1 year, 38% within 2 years and 16% within 3 years of the index operation. Conclusion. Similar findings has been reported on the New Zealand Registry 10 year report where the overall revision rate was 284/4,826 (5.9%), and revision due to disease progression 7.7%. Progression of disease is not a major cause of early failure of UKRs. 73% of the failures occurred within two years of surgery. Other causes such as aseptic loosening, bearing dislocation and instability are more common and could be possibly ameliorated by improved surgical technique, better patient selection and component choice


Bone & Joint 360
Vol. 12, Issue 4 | Pages 16 - 20
1 Aug 2023

The August 2023 Knee Roundup360 looks at: Curettage and cementation of giant cell tumour of bone: is arthritis a given?; Anterior knee pain following total knee arthroplasty: does the patellar cement-bone interface affect postoperative anterior knee pain?; Nickel allergy and total knee arthroplasty; The use of artificial intelligence for the prediction of periprosthetic joint infection following aseptic revision total knee arthroplasty; Ambulatory unicompartmental knee arthroplasty: development of a patient selection tool using machine learning; Femoral asymmetry: a missing piece in knee alignment; Needle arthroscopy – a benefit to patients in the outpatient setting; Can lateral unicompartmental knees be done in a day-case setting?


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_I | Pages 19 - 19
1 Jan 2011
Pandit H Jenkins C Beard D Gill H Price A Dodd C Murray D
Full Access

The results of mobile bearing Oxford unicompartmental knee replacement (UKR) in the lateral compartment have been disappointing (five-year survival: 82%). Therefore, it is recommended that mobile bearings should not be used for lateral UKR. This low survivorship is primarily due to a high dislocation rate. A detailed analysis confirmed the elevated lateral tibial joint line to be a contributory factor to bearing dislocation. A new surgical technique was therefore introduced in which care was taken neither to remove too much bone from the distal femur nor to over tighten the knee and therefore ensure that the tibial joint line was not elevated. Other modifications included use of a domed tibial component. The aim of this study is to compare the outcome of these iterations: the original series (series I), those with improved surgical technique (series II) and the domed tibial component (series III). The primary outcome measure was bearing dislocation at one year. One year was chosen as all the dislocations in the first series occurred within a year. In the original series (n=53), implanted using a standard open approach, there were six dislocations in the first year, the average flexion 110°, and 95% had no/mild pain on activity. In the second series (n=65), there were 3 dislocations, the average flexion was 117°, and 80% had no/mild pain on activity. In the third series with the modified technique and a convex domed tibial plateau, there was one dislocation, average flexion was 125° and 94% had no/mild pain on activity. At four years the cumulative primary dislocation rates were 10%, 5% and 0% respectively, and were significantly different (p=0.04). The improved surgical technique and implant design has reduced dislocation rate to an acceptable level so a mobile bearing can now be recommended for lateral UKR


Orthopaedic Proceedings
Vol. 88-B, Issue SUPP_II | Pages 317 - 317
1 May 2006
Tregonning R
Full Access

The aim was to identify frequency and pattern of early UKR failure in New Zealand. We analysed data from the New Zealand National Joint Register in a 44 month period of 2000–2003. Thirty-five percent of the 1790 registered UKRs were performed in the last 8 months [ie. in 18% of the total time period]. The ratio of UKRs to TKRs performed was 1:6.25. Fifty two revisions meant a failure rate of 2.9% for UKR (n=1790) compared with 1.6% for TKR (n=11243). The most commonly used implants were the Oxford P3 (68% of total with 2.2% revision rate), MG uni (14.6% with 4.6% revision rate) and Preservation (7% with 5.6 revision rate). The most common reasons for revision (n=52) were aseptic loosening (28%), bearing dislocation or impingement (19%), and unexplained pain (13%). The deep sepsis rate for UKR was 0.33% compared to 0.43% for TKR. UKR usage is rapidly increasing in NZ. The revision rate for UKR was 1.8 x that for TKR. The revision rate for deep sepsis was 77% that for TKR. Unexplained pain in apparently technically normal UKR was the 3rd most common reason for revision. Bearing impingement was as common as bearing dislocation as a cause for failure in the Oxford P3 UKR. Early polythene wear was the reason for revision only in the 8mm MG prosthesis


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_I | Pages 117 - 117
1 Mar 2010
Choy W Kim K Ko J
Full Access

Purpose: To analyze the clinical and radiographic results of patients treated by Oxford minimally invasive unicompartmental knee arthroplasty. Materials and Methods: We have operated 166 patients 188 knees of minimally invasive unicompartmental knee arthroplasty(Oxford Uni. ®. ) from January 2002 to December 2005. The mean ages was 65.3 (44–82) years and 16 cases of male and 150 cases of female. The mean follow-up period was 57 (36–77) months. Preoperative diagnosis were osteoarthritis in 166 cases, avascular necrosis of medial femoral condyle in 20 cases and chondrocalcinosis in 2 cases. The clinical results were evaluated using the HSS knee score and the range of motion of knee preoperatively and at the final follow up. At the final follow up, the ability of the patient to assume the squatting and cross-leg position were checked. The tibiofemoral angle was measured preoperatively and postoperatively. Component loosening, radiolucent lines were checked. Result: The HSS knee score was 67.5 (52–86) preoperatively and 89.9 (59–100) at the final follow up. The mean preoperative flexion contracture was 6.5° (0–20) and 0.81 (0–5) at the final follow up. Active full flexion was possible within postoperative 2 months. The squatting position was possible in 133 patients (80.1%) and the cross-leg position was possible in 152 patients (91.6%). The tibiofemoral angle was improved varus 1.5° to valgus 4.8°. Complication occurred in 14 cases (7.4%). Meniscal bearing dislocation in 8 cases (4.3%). Tibial components loosenig in 3 cases (1.6%). Femoral components loosening in 2 cases (1.1%). The average time of meniscal bearing dislocation was 11.3 (3–24)months postoperatively. Six cases returned to the predislocation level of activity with the insertion of thicker bearings and 2cases required TKR conversion. Conclusion: Minimally invasive unicompartmental knee arthroplasty(Oxford Uni. ®. ) provides rapid recovery, good pain relief and excellent function quite suitable to Korean life-style. But given the high complicate rate in mid-term results. Oxford Uni. ®. gives less reliability compared with TKR


Orthopaedic Proceedings
Vol. 88-B, Issue SUPP_I | Pages 92 - 92
1 Mar 2006
Bontemps G Saxler G
Full Access

Introduction: Increasing experiences in determining the indication for UKA and improvements in design and materials of the prosthesis led to better results. The AMC-Uniglide has an unconstrained mobile bearing with congruent area contact. This ensures complete freedom to rotate and slide upon one other with physiologic kinematic and low intrinsic stability. Material and Methods:. Minimal-invasive technique 30 patients with minimal-invasive AMC-Uniglide implantation technique were compared with 30 conventional implanted AMC’s and 30 total knee replacements in regard to rehabilitation and accuracy of implantation. 361AMC-Uniglides 361 consecutive patients were investigated after AMC-Uniglide implantation. The mean duration of follow-up was 5.5 (2.3-12.5) years. Patients were reviewed using the American Knee Society Rating System. The roentgenographic analyses were performed with the American Knee Society Evaluation System. Results:. Minimal-invasive technique The comparison of 30 minimal-invasive UKA with 30 conventional UKA and 30 total knee replacements show an advantage of minimal invasive technique with regard to a reduced time of rehabilitation. The accuracy of implantation was comparable between the conventional and the minimal-invasive technique. 361 AMC-Uniglides Ninety-five percent of patients had no pain or slight pain at the latest follow-up, ninety-two percent had good or excellent clinical outcome. Three knees were revised for mobile bearing dislocation after medial UCA and three for lateral mobile bearing dislocation after lateral UCA. Five revisions because of component loosening were performed and there was one case of deep infection. Conclusion: The clinical results of the investigated patients demonstrate that the AMC-Uniglide is a successful concept with a safe anchorage of the prosthesis and a good durability of the mobile bearings. An advantage of minimal invasive technique with regard to a reduced time of rehabilitation was found. The accuracy of implantation was comparable between the conventional and the minimal-invasive technique


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_15 | Pages 56 - 56
1 Mar 2013
Netter J Hermida J Kester M D'Alessio J Steklov N Flores-Hernandez C Colwell C Lima DD
Full Access

INTRODUCTION. Wear and polyethylene damage have been implicated in up to 22% of revision surgeries after unicompartmental knee replacement. Two major design rationales to reduce this rate involve either geometry and/or material strategies. Geometric options involve highly congruent mobile bearings with large contact areas; or moderately conforming fixed bearings to prevent bearing dislocation and reduce back-side wear, while material changes involve use of highly crosslinked polyethylene. This study was designed to determine if a highly crosslinked fixed-bearing design would increase wear resistance. METHODS. Gravimetric wear rates were measured for two unicompartmental implant designs: Oxford unicompartmental (Biomet) and Triathlon X3 PKR (Stryker) on a knee wear simulator (AMTI) using the ISO-recommended standard. The Oxford design had a highly conforming mobile bearing of compression molded Polyethylene (Arcom). The Triathlon PKR had a moderately conforming fixed bearing of sequentially crosslinked Polyethylene (X3). A finite element model of the AMTI wear simulation was constructed to replicate experimental conditions and to compute wear. This approach was validated using experimental results from previous studies. The wear coefficient obtained previously for radiation-sterilized low crosslinked polyethylene was used to predict wear in Oxford components. The wear coefficient obtained for highly crosslinked polyethylene was used to predict wear in Triathlon X3 PKR components. To study the effect design and polyethylene crosslinking, wear rates were computed for each design using both wear coefficients. RESULTS. Wear rates were significantly lower (69%) for the Triathlon fixed-bearing design compared to the Oxford mobile-bearing design (Fig 1, p<0.01). The FEA model predicted 46% of wear occurring at the back side of the mobile bearing (Fig 2). When wear was computed for the Triathlon PKR design using the wear coefficients used for the low crosslinked polyethylene, wear rates increased to 13.9 mg/million cycles. DISCUSSION. We used a combined experimental and computational approach to quantify factors contributing to polyethylene wear after unicompartmental knee arthroplasty. To isolate the effect of crosslinking level and mobile-bearing design, we computed wear rates for both designs using the same wear coefficient obtained for low crosslinked polyethylene. Wear rates in the low crosslinked Triathlon PKR insert increased by more than 160% relative to those in the highly crosslinked Triathlon X3 PKR. The finite element method facilitates computation of relative back-side to front-side wear, which is challenging to obtain experimentally. The back-side wear Oxford mobile bearing was 46% of total wear. Major factors contributing to the difference in wear were back-side wear (46%) and increased crosslinking (63%) with the combined effect having an additive effect. Our FEA-predicted wear penetration rates (0.024 mm/million cycles) also compare well to in vivo studies, which reported penetration rates of 0.022 mm/year for Oxford bearings. A validated computer model is extremely valuable for efficient evaluation of wear performance and design development. In summary, increasing conformity to increase contact area and reduce contact stress may not be the sole predictor of wear performance. A highly crosslinked polyethylene insert in a fixed-bearing design may provide the high wear performance of a mobile-bearing design without the increased risk for bearing dislocation


The Bone & Joint Journal
Vol. 104-B, Issue 6 | Pages 672 - 679
1 Jun 2022
Tay ML Young SW Frampton CM Hooper GJ

Aims

Unicompartmental knee arthroplasty (UKA) has a higher risk of revision than total knee arthroplasty (TKA), particularly for younger patients. The outcome of knee arthroplasty is typically defined as implant survival or revision incidence after a defined number of years. This can be difficult for patients to conceptualize. We aimed to calculate the ‘lifetime risk’ of revision for UKA as a more meaningful estimate of risk projection over a patient’s remaining lifetime, and to compare this to TKA.

Methods

Incidence of revision and mortality for all primary UKAs performed from 1999 to 2019 (n = 13,481) was obtained from the New Zealand Joint Registry (NZJR). Lifetime risk of revision was calculated for patients and stratified by age, sex, and American Society of Anesthesiologists (ASA) grade.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_9 | Pages 53 - 53
1 May 2016
Moon Y Seo J Kim S Park J
Full Access

Background. The purpose of this study is to report the outcome of navigation-assisted cruciate-retaining total knee arthroplasty (TKA) using one type of cemented, second-generation, floating-platform (FP), mobile-bearing system. Methods. We retrospectively reviewed 42 patients (51 knees) who underwent cruciate retaining TKAs using e.motion-FP prostheses under navigational guidance. The preoperative diagnosis was osteoarthritis in all knees except one rheumatoid arthritis. There were 2 men (2 knees) and 40 women (49 knees) with a mean age of 64.0 ± 4.7 years (range, 51 – 76 years) at the time of index surgery. The mean follow-up was 120.0 months (range, 106 – 126 months). Clinical and radiographic results as well as mechanical survival rate of this type prosthesis were investigated at a mean follow-up of 10 years. Results. The mean mechanical femorotibial angle was improved from 11.7° ± 3.3° (range, 5.0° to 19.7°) preoperatively to 1.4° ± 1.7° (range, −2.9° to 6.4°) at the latest follow-up. No prosthesis-related complications such as bearing dislocation or breakage occurred and no knees showed aseptic loosening or progressive osteolysis. Kaplan-Meier survivorship at 10.5 years was 100% with an endpoint of revision for any prosthesis-associated reason. Conclusions. The emotion-floating platform mobile-bearing design yielded satisfactory mid-term durability and implant performance under navigational guidance


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_14 | Pages 8 - 8
1 Jul 2016
Sheikh N Mundy G
Full Access

The dual mobility (DM) bearing concept was introduced to reduce the risk of dislocation in total hip arthroplasty (THA). Our aim was to evaluate the early outcomes following the utilisation of DM in primary and revision THA in our unit. Prospectively collected data on all patients undergoing a DM bearing at was reviewed between July 2012and December 2015. The primary outcome assessed was dislocation, with a secondary outcome revision for any reasons. All data was gathered from patient clinical records and the digital picture archiving and communication system (PACS). 30 primary THA were undertaken and 54 revision THAin the time period described. 11 of the procedures involved a proximal femoral endoprosthesis. The mean age in the primary setting was 65 and 73 in the revision population. The main indications for using DM bearing in the primary setting were; trauma (40%), residual dysplasia (40%) and malignancy (17%). There were no dislocations in the primary THA category. Indications in the revision THA cohort included 33% for aseptic loosening, 11% for instability, 18% for ALVAL reactions, 20% for infection, 18% for fracture. 1 out of the 54 revision THA had one large bearing dislocation requiring closed reduction. Subsequent analysis confirmed that implant alignment was satisfactory and this was a patient compliance issue due to mental health concerns. To date no patient in either cohort required revision surgery. Overall dislocation rate was 1.2%. Our early experience with DM bearings has been positive with no evidence of early failure or loosening. The dislocation rate overall has been low and matches the current large series in the literature


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_1 | Pages 142 - 142
1 Jan 2016
Fukushima S Togashi E Sugawara H Narita A Takagi M
Full Access

It is very important for implanting tibial component to prevent bearing dislocation in Oxford UKA. One of the keys is accurate rotational position of tibia. But the problem remains what is accurate rotation of tibia in UKA. Oxford Signature decided the rotation of tibia component from MRI images. We measured the component rotation of tibia using CT after operation. Patients and Methods. 14 patients were operated by Oxford Signature and 11 patients were operated by Microplasty method. Patients were examined by CT 2 or 3 weeks later after operation. We compared component axis of tibia and A-P axis by best fit circle, Akagi's line. Results. In Oxford Signature group, component angle were 7.1 degree external rotation compared with A-P axis by best fit circle and were 3.6 degree external rotation compared with Akagi's line. In Microplasty group, component angle were 8.1 degree external rotation compared with A-P axis by best fit circle and were 3.8 degree external rotation compared with Akagi's line. Discussion. It is difficult to decide accurate position of tibial component for UKA. The A-P axis by best fit circle and Akagi's line are reliable methods for tibial axis in TKA. We examined component axis of Signature Oxford and Microplasty, these were same tendency toward external rotation


The Bone & Joint Journal
Vol. 103-B, Issue 7 | Pages 1261 - 1269
1 Jul 2021
Burger JA Zuiderbaan HA Sierevelt IN van Steenbergen L Nolte PA Pearle AD Kerkhoffs GMMJ

Aims

Uncemented mobile bearing designs in medial unicompartmental knee arthroplasty (UKA) have seen an increase over the last decade. However, there are a lack of large-scale studies comparing survivorship of these specific designs to commonly used cemented mobile and fixed bearing designs. The aim of this study was to evaluate the survivorship of these designs.

Methods

A total of 21,610 medial UKAs from 2007 to 2018 were selected from the Dutch Arthroplasty Register. Multivariate Cox regression analyses were used to compare uncemented mobile bearings with cemented mobile and fixed bearings. Adjustments were made for patient and surgical factors, with their interactions being considered. Reasons and type of revision in the first two years after surgery were assessed.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_1 | Pages 102 - 102
1 Jan 2016
D'Lima D Netter J D'Alessio J Kester M Colwell C
Full Access

Background. Wear and fatigue damage to polyethylene components remain major factors leading to complications after total knee and unicompartmental arthroplasty. A number of wear simulations have been reported using mechanical test equipment as well as computer models. Computational models of knee wear have generally not replicated experimental wear under diverse conditions. This is partly because of the complexity of quantifying the effect of cross-shear at the articular interface and partly because the results of pin-on-disk experiments cannot be extrapolated to total knee arthroplasty wear. Our premise is that diverse experimental knee wear simulation studies are needed to generate validated computational models. We combined five experimental wear simulation studies to develop and validate a finite-element model that accurately predicted polyethylene wear in high and low crosslinked polyethylene, mobile and fixed bearing, and unicompartmental (UKA) and tricompartmental knee arthroplasty (TKA). Methods. Low crosslinked polyethylene (PE). A finite element analysis (FEA) of two different experimental wear simulations involving TKA components of low crosslinked polyethylene inserts, with two different loading patterns and knee kinematics conducted in an AMTI knee wear simulator: a low intensity and a high intensity. Wear coefficients incorporating contact pressure, sliding distance, and cross-shear were generated by inverse FEA using the experimentally measured volume of wear loss as the target outcome measure. The FE models and wear coefficients were validated by predicting wear in a mobile bearing UKA design. Highly crosslinked polyethylene (XLPE). Two FEA models were constructed involving TKA and UKA XLPE inserts with different loading patterns and knee kinematics conducted in an AMTI knee wear simulator. Wear coefficients were generated by inverse FEA. Results. Predicted wear rates were within 5% of experimental wear rates during validation tests. Unicompartmental mobile bearing back-side wear accounted for 46% of the total wear in the mobile bearing. Wear during the swing phase was 38% to 44% of total wear. Discussion & Conclusions. Crosslinking polyethylene primarily decreased (by nearly 10-fold) the wear generated by cross-shear. This result can be explained by the reduced propensity of crosslinked polyethylene molecules to orient in the dominant direction of sliding. A highly crosslinked fixed-bearing polyethylene insert can provide high wear performance without the increased risk for mobile bearing dislocation. Finite element analysis can be a robust and efficient method for predicting experimental wear. The value of this model is in rapidly conducting screening studies for design development, assessing the effect of varying patient activity, and assessing newer biomaterials. This FEA model was experimentally validated but requires clinical validation


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_13 | Pages 41 - 41
1 Sep 2014
Riemer B Grobler G Dower B MacIntyre K
Full Access

Background and Purpose of Study. The Valgus knee in total knee Arthroplasty, is considered a more demanding procedure, often with ligament balance a greater challenge than seen with neutral or Varus knees. It has also frequently been suggested that prostheses with higher levels of constraint be used to avoid late-onset instability. Various lateral release techniques have also been suggested in the literature. This study is aimed at assessing the outcomes of an unconstrained, rotating platform designed prosthesis, the LCS, using our technique, in the management of severe valgus deformity. Methods. 44 knees in 42 patients with a pre-operative valgus deformity of more than 10 degrees were included in our retrospective series. We analyzed the radiographs for the degree of correction, the angle of tibial tray implantation, and femoral implantation angle, tibial slope, as well as the presence (or degree) of lift off and any complications were noted. In this group, 7 had a Valgus deformity of greater than 25 degrees, with a mean Valgus deformity of 17,36 degrees. The mean age at operation was 65. Clinical and radiological analysis was done Pre-hospital discharge and again post-operatively 6 weeks. Results. The mean coronal alignment was corrected from 17,36 degrees to 5 degrees of Valgus post operatively. 2 knees were corrected past neutral to varus alignment. There was 1 case of bearing spin out experienced early on in the series. The mean tibial implant angle was 1,7 degrees from neutral. Lift off in the early post-operative X-rays was seen in 6 patients, however at 3 month follow up the knees appeared to be well balanced. There were no infections or revisions for wear, one re-operation for bearing dislocation, and no cases of loosening in our series. There were no cases of delayed instability. Patient satisfaction was 86 %. Conclusions. The rotating platform, mobile bearing prosthesis, using our technique, provided a reproducible correction of deformity in Valgus knees, a well-balanced knee, a low complication rate, and an excellent degree of patient satisfaction. NO DISCLOSURES


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_10 | Pages 12 - 12
1 Feb 2013
Clement A Baird K
Full Access

A review of current literature describes varying 10-year survival rates for the Oxford Unicompartmental Knee Replacement (Biomet Orthopedics Inc, Warsaw, Ind). Application of rigorous indications and meticulous surgical technique are two factors considered to reduce revision rates. A retrospective case-note review was conducted for 96 patients (128 knees) aged 42–89 (mean 57) who had an Oxford unicompartmental knee replacement for medial compartment osteoarthritis between January 2000 and January 2011. All procedures were performed, or directly supervised, by one 5 surgeons. The aim of the study was to ascertain the rate of revision to bicompartmental knee replacement and any associated contributory factors. Of the 128 unicompartmental knees, 10.9% were revised to either mobile- or fixed-bearing total knee replacements due to septic (0.5%) and aseptic (1.5%) loosening, patello-femoral pain (3.9%), periprosthetic fracture (0.8%) and bearing dislocation (3.1%). Of those knees requiring revision, mean patient age was 73 years, 50% had wound complications and 42% were performed by senior trainees. All patients had intact ACL and medial osteoarthritis. Mean time to revision was 2.7 years. In conclusion, revision of the unicompartmental knee was related to patient age > 65 years and early post-operative complications; grade of operating surgeon had little apparent effect


Bone & Joint Research
Vol. 10, Issue 11 | Pages 723 - 733
1 Nov 2021
Garner AJ Dandridge OW Amis AA Cobb JP van Arkel RJ

Aims

Bi-unicondylar arthroplasty (Bi-UKA) is a bone and anterior cruciate ligament (ACL)-preserving alternative to total knee arthroplasty (TKA) when the patellofemoral joint is preserved. The aim of this study is to investigate the clinical outcomes and biomechanics of Bi-UKA.

Methods

Bi-UKA subjects (n = 22) were measured on an instrumented treadmill, using standard gait metrics, at top walking speeds. Age-, sex-, and BMI-matched healthy (n = 24) and primary TKA (n = 22) subjects formed control groups. TKA subjects with preoperative patellofemoral or tricompartmental arthritis or ACL dysfunction were excluded. The Oxford Knee Score (OKS) and EuroQol five-dimension questionnaire (EQ-5D) were compared. Bi-UKA, then TKA, were performed on eight fresh frozen cadaveric knees, to investigate knee extensor efficiency under controlled laboratory conditions, using a repeated measures study design.


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_2 | Pages 35 - 35
1 Jan 2019
Zaribaf F Gill HR Pegg E
Full Access

Ultra-high molecular weight polyethylene (UHMWPE) is a commonly used as bearing material in joint replacement devices. UHMWPE implants can be hard to see on a standard X-ray because UHMWPE does not readily attenuate X-rays. Radiopaque UHMWPE would enable direct imaging of the bearing both during and after surgery, providing in vivo assessment of bearing position, dislocation or fracture, and potentially a direct measure of wear. The X-ray attenuation of UHMWPE was increased by diffusing an FDA approved contrast agent (Lipiodol) into UHMWPE parts (Zaribaf et al, 2018). The aim of this study was to evaluate the optimal level of radiopacity for a UHMWPE bearing. Samples of un-irradiated medical grade UHMWPE (GUR 1050) were machined into 4mm standard medium Oxford Unicompartmental bearings. Samples were immersed in Lipiodol Ultra Fluid (Guerbert, France) at elevated temperatures (85 °C, 95 °C and 105 °C) for 24 h to achieve three different levels of radiopacity. A phantom set-up was used for X-ray imaging; the phantom contained two perspex rods to represent bone, with the metallic tibial tray and polyethylene bearing fixed to the end of one rod and the metallic femoral component fixed to the other rod. Radiographs of the samples were taken (n=5) with the components positioned in full extension. To ensure consistency, the images of all the samples were taken simultaneously alongside an untreated part. The results of our ongoing study demonstrate that the radiopacity of UHMWPE can be enhanced using Lipiodol and the parts are visible in a clinical radiographs. The identification of the optimal treatment from a clinical perspective is ongoing; we are currently running a survey with clinicians to find the consensus on the optimal radiopacity taking into account the metallic components and alignment. Future work will involve a RSA study to assess the feasibility of measuring wear directly from the bearing


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_15 | Pages 335 - 335
1 Mar 2013
Song I Lee C
Full Access

Purpose. We analyzed the frequency, causes and treatment of dislocation of polyethylene insertion among various causes of failure of unicompartmental knee arthroplasty. Materials and Methods. We studied 69 knee joints of 65 patients who underwent medial unicompartmental knee arthroplasty using from June 2005 to December 2010. Average age was 61.8 and average follow-up period was 20 months. Radiologic results evaluated preoperative and postopertative mechanical axis deviation, tibio-fibular angle and postoperative implant position in total 69 knees(A group), failed 15 cases(B group) and 10 cases(C group) of bearing dislocation. We demonstrated treatment on failure group and analyzed preoperative and postoperative HSS and Lysolm score. Results. Failures were observed in 15 cases(21.7%) on follow-up. dislocation of polyethylene insertion was observed in 10 cases at average 26.7 months (3–60). There were 2 cases of dislocation of insert without loosening of implant and 8 cases of dislocation of insert with loosening of implant. Tibio-femoral angle in A, B and C group were corrected form preoperative varus 8.1°, 7.3° and 6.3° to postoperative valgus 3.6°, 4.0° and 3.5°. Thickness of inserted polyethylene in A, B and C were 4.7 mm, 5.2 mm and 4.8 mm, but each groups didn't show statistical significance. HSS and Lysolm score improvement had statistical significance. Conclusion. Dislocation of polyethylene insert (66.1%) in cases of the failure was most common. Coronal correction angle and thickness of inserted polyethylene showed no difference between dislocation gourp and non-dislocation group, so we consider that polyethylene dislocation after unicompartmental knee arthroplasty seems to be due to structural problem of the implant


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_II | Pages 113 - 113
1 May 2011
Malhotra R Kumar V Eachempati K Bhan S
Full Access

Background: Durable long-term independent results with the Low Contact Stress rotating-platform (mobile-bearing) and the Insall Burstein-II (fixed-bearing) total knee prostheses have been reported, but no studies describing either the mid-term or long-term results and comparing the two prostheses are available, to our knowledge. Methods: Thirty-two patients who had bilateral arthritis of the knee with similar deformity and preoperative range of motion on both sides and who agreed to have one knee replaced with a mobile-bearing total knee design and the other with a fixed-bearing design were prospectively evaluated. Comparative analysis of both designs was done at a mean follow-up period of six years, minimizing patient, surgeon, and observer-related bias. Clinical and radiographic outcome, survival, and complication rates were compared. Results: Patients with osteoarthritis had better function scores and range of motion compared with patients with rheumatoid arthritis. However, with the numbers available, no benefit of mobile-bearing over fixed-bearing designs could be demonstrated with respect to Knee Society scores, range of flexion, subject preference, or patellofemoral complication rates. Radiographs showed no difference in prosthetic alignment. Two knees with a mobile-bearing prosthesis required a reoperation: one had an early revision because of bearing dislocation and another required conversion to an arthrodesis to treat a deep infection. Conclusions: We found no advantage of the mobile-bearing arthroplasty over the fixed-bearing arthroplasty with regard to the clinical results at mid-term follow-up. The risk of bearing subluxation and dislocation in knees with the mobile-bearing prosthesis is a cause for concern and may necessitate early revision


The Bone & Joint Journal
Vol. 102-B, Issue 8 | Pages 1033 - 1040
1 Aug 2020
Kennedy JA Mohammad HR Yang I Mellon SJ Dodd CAF Pandit HG Murray DW

Aims

To report mid- to long-term results of Oxford mobile bearing domed lateral unicompartmental knee arthroplasty (UKA), and determine the effect of potential contraindications on outcome.

Methods

A total of 325 consecutive domed lateral UKAs undertaken for the recommended indications were included, and their functional and survival outcomes were assessed. The effects of age, weight, activity, and the presence of full-thickness erosions of cartilage in the patellofemoral joint on outcome were evaluated.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_15 | Pages 223 - 223
1 Mar 2013
Kim K
Full Access

Purpose. To identify the causes of failure after unicompartmental knee arthroplasty (UKA), and to evaluate considerations for surgical procedures and the results of revision total knee arthroplasty (TKA) performed after failure of UKA. Materials and Methods. Eight hundreds and fifty-two cases of UKA were performed from January 2002 to June 2011. Forty-seven cases of failures after UKA were analyzed for the cause of the failures, and thirty-five cases of revision TKA after failure were analyzed for the operative findings and surgical technique. The clinical results were measured for thirty cases which were followed-up on at least two years after TKA. The mean duration of follow-up was four years and one month after revision TKA and the mean patient age at the time of surgery was sixty-five years. Results. For the cause of failures after UKA, there were twenty-two cases of early loosening of prosthesis, seventeen cases of simple mobile bearing dislocation, five cases of infection, one case of fracture of medial tibial condyle and two cases of unknown origin pain. In operative findings of thirty-five cases of TKA after failed UKA, there were twenty-five cases of bone defect requiring treatment and the mean thickness of the defect was 10.6 mm. For the treatment of bone defect, there were five cases of autogenous bone graft, twenty-one cases of metal blocks, and one case of autogenous bone graft with metal block. The stem was used in tibial implants for nineteen cases, and one case of use in tibial and femoral implants. For thirty cases where follow ups were possible at least two years after operation, the mean knee score was improved from 68.2 to 85.2 and the mean knee function score was improved from 67.7 to 78.0 at the last follow-up, respectively. The mean range of knee motion was 107.2° pre-operatively, which was recovered to 120.7° after the operation. The mean tibiofemoral angle was changed from 1.7° of valgus to 5.2° of valgus. Conclusion. As shown in this study, the tibial bone defect was the most important problem in revision TKA after failure of UKA. Therefore, proper indication and accurate surgical technique using autogenous bone graft, metal block and stemmed implants would be able to achieve satisfactory results in revision TKA after failure of UKA


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXIII | Pages 106 - 106
1 May 2012
Viswanathan S
Full Access

Mobile bearings in knee arthroplasty carry the theoretical advantage of lower wearing prostheses. However, dislocating mobile bearings can be a significant issue in mobile bearing knee replacement arthroplasty. Our aim is to report our design alterations to the insert to address bearing spinout. A total of 598 RBK mobile bearing total knee arthroplasties were performed by the senior author over a 10–year period. The standard bearing was subjected to three design changes to address spinout and increase flexion range. The first alteration involved a deeper dish with a higher anterior lip. Subsequently, a reduced footprint insert (RFI) was created. The final modification was a shaved off posterior rim to allow for greater flexion (high flex). An overall bearing dislocation rate of 1.0% (6 out of 595) was obtained. Of these 595 knees, 132 were of the initial insert design, 194 were deep-dished inserts, 71 inserts were RFI, and 198 were high flex. There were four (3%) dislocations with the initial insert design and two (1%) dislocations in the final implant version. In our series the dislocated bearings have in all but one required revision to higher constrained prostheses. The mechanism of dislocation is speculated to be instability in flexion, leading to posterior loading of the insert and spinning out of the bearing. Most of the bearing subluxations have been medial but one was observed intra operatively to be a lateral extrusion. With respect to the two dislocations in the final implant design, one dislocation was attributed to a technical error of under sizing the insert. At revision surgery he was also found to have a disrupted MCL, which was repaired. He has had no further issues after the insert was upsized. The cause of spin out in the second patient was speculated to be obesity and a diminished pre- operative range of movement. She required a revision to a higher constrained prosthesis. Insert spinout has a multifactorial aetiology. The occurrence of spinout can be minimised by a combination of good surgical technique, such as balanced flexion and extension gaps and design modifications to the insert as we have instituted


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_I | Pages 19 - 19
1 Jan 2011
Pandit H Jenkins C Beard D Gill H Price A Dodd C Murray D
Full Access

About ten years ago we introduced sophisticated instrumentation and an increased range of component sizes for the Oxford unicompartmental knee replacement (UKR) to facilitate a minimally invasive surgical (MIS) approach. The device is now routinely implanted through an incision from the medial pole of the patella to the tibial tuberosity. This has resulted in a more rapid recovery and an improved functional result. As the access to the knee is limited there is a concern that the long term results may be compromised. The aim of this study was to determine the 10 year survival. A prospective follow up of all Phase 3 minimally invasive Oxford UKR implanted by two senior authors (DWM & CAFD) has been undertaken. So far 1015 UKRs have been implanted for anteromedial osteoarthritis. All patients received a cemented implant through a MIS approach and were followed up prospectively by an independent observer. The data was collected prospectively regarding pre-operative status, complications and clinical as well as functional outcome at predetermined intervals. The average age of patients was 66.4 years (range: 33 – 88) with mean Oxford Knee Score 41 (SD: 7.9) at the time of last follow up, Knee Society Score (objective) of 84 (SD: 13) and Knee Society Score (functional) of 83 (SD: 21). At ten years the survival of this cohort is 96%. There were 22 revisions including 7 for progression of arthritis, 5 for infection, 5 for bearing dislocation, 4 for unexplained pain and one for rupture of ACL secondary to trauma. We conclude that the Oxford Knee can be implanted reliably through a minimally invasive approach, giving excellent long term results


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXI | Pages 117 - 117
1 May 2012
R. T T. H C. F A. R
Full Access

Purpose. To identify the incidence and reasons for revision of the Oxford prosthesis (OXF) in New Zealand. Methods. Review and compare UKA and TKA data including patient-generated Oxford scores after operation. Results. 105 surgeons performed 3,624 OXF (66.5% of all UKA). UKA made up 12.8% of all knee arthroplasties. There were 216 OXF revisions and revision rate (RR) of 1.39 per 100 component-years (p100cy); for UKA this was 1.42 p100cy, and for TKA 0.54 p100cy (OXF vs TKA p< 0.0001). The indications for OXF revisions were unexplained pain (38.0%); aseptic loosening (38.0%); bearing dislocation (9.3%) and deep sepsis (4.2%). For TKA, unexplained pain (28%) was significantly lower than from OXF (p=0.005). Revision for deep sepsis was significantly lower for OXF compared with TKA (4.2% vs 13.1%, p < 0.001). The Oxford scores 6 months post-op were excellent or good in 79% of OXF vs 72% TKA patients (p< 0.0001); at 5 years after operation these were 88% for OXF and 81% for TKA (p=0.001). Twenty high-use OXF surgeons (10 or more operations/year) performed 44% of the operations (RR of 1.3 p100cy), 62 medium-use surgeons (2-9/year) performed 54% (RR of 1.3 p100cy). 23 low-use surgeons (2 or less/year) performed 2% (RR of 3.9p100cy). The differences in RR high vs low users (p< 0.001) and medium vs low groups (p< 0.001) were significant. RR for OXF high or medium users was significantly higher than the overall rate for TKA (p< 0.001). Conclusion. RR for the OXF was 2.5 times greater than that for TKA. Deep infection rate was lower, and 6-month and 5-year function scores were significantly higher OXF vs TKA


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_III | Pages 286 - 286
1 Jul 2011
David M Datta A Baloch K
Full Access

Introduction: Unicompartmental knee replacement (UKR) is a popular alternative to total knee replacement (TKR) in medial compartment disease. Early problems include bearing dislocation, persistent pain, stiffness and infection. Revision to TKR is well described as a late endpoint. Objective: Investigate the early surgical management of persistent pain and debility following UKR, identify common themes and rate effectiveness of any re-intervention. Methods: 381 UKRs implanted over 5 years included, and patients requiring re-operation reviewed retrospectively. Findings: 27 re-operations performed on 17 patients at a mean 16.8 months (95% CI 9.5 to 24.1), with symptom onset post-operatively at 9 months (95% CI 4–14). There were 10 arthroscopies, 10 total knee replacements (revision), 4 manipulations under anaesthesia, 2 bearing exchanges, and 1 tibial-plateau fracture fixation. Manipulation under anaesthesia improved stiffness in 2 of 3 patients. Arthroscopy was successful in 2 patients with loose cement-bodies but did not provide a diagnosis in 8 patients, of whom 7 were revised subsequently after 17.1 months (95% CI 10.1 to 24.1) with 6 reporting symptom resolution. Overall there were 10 revisions: 9 were performed for persistent pain and 9 reported symptom improvement. Intra-operative findings included aseptic loosening (n=4), synovitis (n=2), increased posterior slope of the tibial cut (n=1), dislocated bearing (n=1), and no cause of failure in 2. Only two cases required revision implants with medial augments for bone loss. There were no deep infections. Conclusions: The early re-intervention rate at our unit is 4.5% (95% CI 2.4 to 6.5), with a revision rate of 2.6% (95% CI 1.0 to 4.2) after a mean (±SD) follow-up of 40.1 (±16) months. Arthroscopy is a poor diagnostic and therapeutic option against persistent pain following UKR. In contrast, the decision to revise, although initially disappointing for both patient and surgeon, gave symptom improvement in 90%


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 422 - 422
1 Sep 2012
Weston-Simons J Pandit H Kendrick B Beard D Gibbons M Jackson W Gill H Price A Dodd C Murray D
Full Access

Introduction. The options for the treatment of the young active patient with unicompartmental symptomatic osteoarthritis and pre-existing Anterior Cruciate Ligament (ACL) deficiency are limited. Patients with ACL deficiency and end-stage medial compartment osteoarthritis are usually young and active. The Oxford Unicompartmental Knee Replacement (UKA) is a well established treatment option in the management of symptomatic end-stage medial compartmental osteoarthritis, but a functionally intact ACL is a pre-requisite for its satisfactory outcome. If absent, high failure rates have been reported, primarily due to tibial loosening. Previously, we have reported results on a consecutive series of 15 such patients in whom the ACL was reconstructed and patients underwent a staged or simultaneous UKA. The aim of the current study is to provide an update on the clinical and radiological outcomes of a large, consecutive cohort of patients with ACL reconstruction and UKA for the treatment of end-stage medial compartment osteoarthritis and to evaluate, particularly, the outcome of those patients under 50. Methods. This study presents a consecutive series of 52 patients with ACL reconstruction and Oxford UKA performed over the past 10 years (mean follow-up 3.4 years). The mean age was 51 years (range: 36–67). Procedures were either carried out as Simultaneous (n=34) or Staged (n=18). Changes in clinical outcomes were measured using the Oxford Knee Score (OKS), the change in OKS (OKS=Post-op − Pre-op) and the American Knee Society Score (AKSS). Fluoroscopy assisted radiographs were taken at each review to assess for evidence of loosening, radiolucency progression, (if present), and component subsidence. Results. Five year survival was 90%. At last follow-up, the mean outcome scores for the group were: OKS 40 (SD: 8.3), objective AKSS 77 (SD: 16.1), functional AKSS 93 (SD: 13.7) and OKS of 11. Complications were recorded in three patients, (one early infection requiring a two-stage revision, a bearing dislocation and progression of OA in the lateral compartment). 25 patients, whose procedure occurred under the age of 50, had mean outcome scores of: OKS 38 (SD: 7.7), objective AKSS 73 (SD: 20.2), functional AKSS 93 (SD: 11.9) and OKS 12. No patients had radiological evidence of component loosening. Discussion and Conclusion. This study has demonstrated that combined ACL reconstruction and Oxford UKA provide good medium-term clinical and radiological results. The mobile bearing used in the Oxford knee minimises wear and our radiographic study has seen no suggestions of loosening


Orthopaedic Proceedings
Vol. 90-B, Issue SUPP_III | Pages 579 - 579
1 Aug 2008
Price A Svard U
Full Access

Aim: This paper presents the 20-year survival and 10-year clinical follow-up results from the entire series of all medial Oxford meniscal bearing unicompartmental knee arthroplasties performed in a single centre in Sweden, between 1985 and 2004. Method: Patients were contacted and information about the state of the knee collected. Revision surgery was used in the life-table survival analysis performed. For the entire cohort clinical follow up at 10-years is routinely performed, using the HSS knee score. Results: The entire group comprised of 683 knees in 572 patients. The mean age at implantation was 69.7 (range 48–94). There had been 30 revision procedures: 8 for lateral arthrosis, 7 for component loosening, 3 for infection, 6 for bearing dislocation, 1 for bearing fracture and 5 for unexplained pain. The 10-year, 15-year and 20-year survival (all cause revision) were 94.1 % (CI 2.9, 237 at risk), 93.5% (CI 4.6, 101 at risk) and 92.3% (CI 15.1, 11 at risk) respectively. From the patients reviewed clinically the mean pre-operative HSS knee score was 57 (95% CI 1), compared to 87 (95% CI 1) at 10-years. Using HSS criteria the results were: 68% excellent, 23% good, 6% moderate and 2% poor. Conclusion: The results show that this mobile bearing unicompartmental prosthesis offers patients excellent clinical results during the first decade and is durable during the second decade after implantation


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 249 - 249
1 Sep 2012
Kendrick B Weston-Simons J Sim F Gibbons M Pandit H Gill H Price A Dodd C Murray D
Full Access

Introduction. Radiolucencies beneath the tibial component are well recognized in knee arthroplasty; the aetiology and significance are poorly understood. Non-progressive narrow radiolucencies with a sclerotic margin are thought not to be indicative of loosening. Factors which decrease the incidence of radiolucencies include cementless fixation and the use of pulse lavage. Leg/component alignment or BMI do not influence radiolucency. We are not aware of any studies that have looked at the effect of load type on radiolucency. The Oxford domed lateral tibial component was introduced to decrease the bearing dislocation rate that was unacceptably high with the flat tibial tray. However, the introduction of the domed tibial component alters the forces transmitted through the implant-cement-bone interface. As the Oxford UKR uses a fully congruent mobile bearing, the forces transmitted through the interface with a flat tray are compressive, except for the effect of friction. However, with the domed tibial component shear forces are introduced. The aim of this study was to assess the prevalence of radiolucency beneath the previous flat design and the new domed tibial tray. Patients and methods. A consecutive series of 248 cemented lateral UKRs (1999–2009) at a single institution were assessed. The first 55 were with a flat tibia and the subsequent 193 with a domed component. One year post-op radiographs were assessed, by two observers, for the presence (full or partial) and distribution of radiolucency. The distribution and thickness of each radiolucency. Cases were excluded for missing or poorly aligned radiographs. Results. In the flat group there were 42 patients (17 male, 25 female) with 42 joints. In the domed group there were 139 patients (44 male, 95 female) with 146 joints. There was a statistical significant difference between groups for the presence and extent of radiolucency (p<0.001). In the flat group, 6 (14%) had a full radiolucency and 18 (43%) had a partial radiolucency. 14 of the 18 partial radiolucencies involved the far lateral zones (1&2) and 3 partial radiolucencies involved the keel. In the domed group 6, (4.1%) had a full radiolucency and 13 (8.9%) had a partial radiolucency. All radiolucencies observed were less than 1 mm thick. Intra-class correlation for inter-observer agreement for assessment of radiolucency was 0.679. Discussion. The introduction the domed lateral tibial component results in a reduction in prevalence of radiolucency compared to a flat component. This suggests, as the mode of fixation is identical, that the forces across the tibial-cement-bone interface have a significant effect on the development of the tissue at that interface. In particular it suggests that compressive forces alone tend to cause soft tissue to be formed at the interface, whereas shear force causes bone


Orthopaedic Proceedings
Vol. 86-B, Issue SUPP_IV | Pages 441 - 441
1 Apr 2004
Pandit H Beard D Jenkins C Isaac S Lisowski L Abidien Z Keyes G Lisowski A Fievez A Gill HS Dodd C Murray D
Full Access

Introduction: Oxford Unicompartmental knee arthroplasty (UKA) is now performed using a minimally invasive surgical (MIS) technique. Although early results are encouraging, the studies assessing outcome could be criticised for the restricted number of patients and centres involved. A multi-centre follow-up of patients is required to confirm the preliminary findings. Aim: To examine early clinical outcome in patients with minimally invasive Oxford medial UKA using a multi-centre, multi-surgeon design. Materials and Methods: This prospective study was carried out in three centres with involvement of six surgeons. All patients undergoing cemented Oxford UKA for medial OA using MIS were included. 231 consecutive UKAs with a minimum follow up of 2 years (mean: 2.84) were assessed using objective and functional Knee Society Score (KSS). Results: There were 108 females and 102 males (21-bilateral) with average age of 66.8 years (42 – 86). No significant difference was noted between various age groups or between different surgeons. Three knees were revised: one for infection, one for unexplained pain and one for bearing dislocation. Cumulative survival rate at 2 years was 98.6% with 93% patients having good or excellent KSS rating. Conclusions: This multi-centre study has confirmed preliminary findings that Oxford UKA using a minimally invasive approach is safe and effective


Orthopaedic Proceedings
Vol. 88-B, Issue SUPP_II | Pages 318 - 318
1 May 2006
Hartnett N Tregonning R Rothwell A Hobbs T
Full Access

To identify frequency and patterns of Oxford Phase 3 UKA failure in New Zealand through analysis of national primary and revision data. Retrospective audit examining all revision Oxford Phase 3 UKAs recorded in the New Zealand National Joint Register from January 2000 to October 2003 were analysed along with surgeons’ clinical notes and patient x-rays. Seventy-three Orthopædic Surgeons performed 1216 Oxford UKAs. The average age was 66.4 years (range 35–94). Osteoarthritis was the primary diagnosis for 1163 (96%) patients. Mean time to revision was 437 days (14.4 months). The early revision rate was 2.2% (n=27). The most common reasons for revision were aseptic loosening (n=7, 26%), bearing dislocation (n=5, 19%) and pain (n=4, 15%). The deep infection rate was 0.16% (2/1216). Eighteen surgeons (high use > 8 UKAs/year) performed 787 (64%) operations, with a revision rate of 1.5%. Twenty-two surgeons (low use ≤ 1 UKA/year) performed 38 (3%) operations, with a revision rate of 8%. This was statistically significant, p= 0.03 (odds ratio 5.7). The early revision rate for the Oxford UKA is 1.4 times greater than TKA. High use surgeons revision rate is lower than TKA. An inverse relationship between failure and surgeon experience exists. This confirms Swedish Knee Arthroplasty Register findings


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_15 | Pages 27 - 27
1 Mar 2013
Burnett S Nair R Jacks D Hall C
Full Access

Introduction. Unicompartmental knee arthroplasty (UKA) is a successful procedure for medial compartment osteoarthritis (OA). Recent studies using the same implant report a revision rate of 2.9%. Other centers have reported revision rates as high as 10.3%. The purpose of this study was to retrospectively review the clinical results of Oxford Phase 3 UKA's performed in the setting of isolated medial compartment OA and to compare our results to the previous mid-term studies. Our secondary goal was to determine reasons for revision and evaluate selected independent predictors of failure. Methods. A retrospective review of 465 Oxford Phase 3 medial UKA's performed on 386 patients (222 female; 164 male) with isolated medial compartment OA. The average age at surgery was 69.5 years (40–88). Outcome measures included: Knee Society Scores(KSS), Oxford Knee Scores(OKS), SF-12, WOMAC, revision rates, and patient satisfaction. We evaluated independently predictors of failure including: gender, body mass index(BMI), number of previous surgeries, implant sizes, cement technique (simultaneous vs staged), cement type. Revision rates based upon the polyethylene thickness (defined as thin 3–4 mm; medium 5–6 mm; thick 7–9 mm). The need for stems and augments and the degree of constraint required at revision to a total knee arthroplasty (TKA) were evaluated. Results. At a mean follow-up of 60.7 months (11–114) OKS improved from 21 to 37 points (p<.05). Latest SF-12 score was 43.8 points (16.8–64.7 points; SD, 10.5) and WOMAC was 80 points (23–100 points; SD, 18). The overall revision rate was 6.9% (32/465 knees). Mean time to revision in 25 knees was 34.5 months (7–96), and revision was most commonly performed for lateral compartment OA (10). Eight knees were revised for tibial loosening, femoral loosening (6), and PCL failure (1). Revision implants included posterior stabilized in 13 knees (52%), cruciate retaining in 9 knees (36%), and cruciate substituting/dished in 3 knees (12%). Five revisions (20%) required tibial augments and 2(8%) had cemented tibial stems. The mean revision polyethylene thickness was 12 mm (range, 9–19 mm) and one knee required a constrained polyethylene. Three knees are pending revision to TKA. Four knees underwent poly exchange for bearing dislocation and 3 knees had further arthroscopic procedures. Eighty-four percent of the patella were resurfaced at revision. Three quarters (76%) of the patients were extremely or very satisfied with their surgery. Over 90% would have had their surgeries again. Gender, BMI, number of previous surgeries, femoral or tibial sizing, poly thickness, cementing technique or type did not predict revision, the need for constraint, or the need for stems or augments. Conclusion. Our revision rate of 6.9% was comparable to other midterm studies from independent centers but not as low as recently reported results from Oxford. Progression to lateral compartment OA was the most common reason for revision. We could not find any independent predictors of failures in this group of 465 knees


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXV | Pages 203 - 203
1 Jun 2012
Schelfaut S
Full Access

Introduction. Despite the theoretical advantages of mobile bearings for lateral unicompartmental knee replacement (UKR), the failure rate in the initial published series of the lateral Oxford UKR's was unacceptably high. The main cause of failure was early dislocation. In contrast, dislocations of bearings in medial UKR's are rare. The lateral compartment present a higher laxity in flexion than the medial. An adaptation of the lateral design by introducing a convex tibial component and biconcave bearing should tackle this difference in kinematics. The risk of dislocation increased substantially if the lateral tibial joint line was elevated, quantified by the proximal tibial varus angle. This angle had a significant relationship to dislocation. A recent kinematic study identified roughly 3 times as much posterior translation of the tibia during deep knee bend activities after lateral UKR compared to the normal knee, possibly also resulting in a higher incidence of bearing dislocation. With the exception of dislocation, the overall early complication ratio in the initial published series of lateral Oxford UKR was also rather high compared to the last published series. Is there a learning curve?. Materials and Methods. Between January 2009 and April 2010, 16 domed lateral Oxford unicompartmental knee replacements were implanted by the senior author. The valgus deformity was in 2 cases not completely correctable. All femoral components were positioned anatomically. In no case the popliteus tendon was divided. A partial iliotibial band (ITB) release was done in 2 cases. The most common tracking deviation of the bearing peroperatively was a small lift off in deep flexion, seen in 6 cases. Results. Dislocation: no. Clinical outcome. Twelve of our patients (75%) have already good or excellent results with no pain in rest, no or mild pain with activity and good restoration of function. One patient feels some pain in deep flexion during work as a carpenter. In only one patient there is still a flexion of less than 100°. Small extension deficits are seen in 4 patients. Radiographic outcome. The full-leg radiographs showed a valgus axis of 1,2° (-1° to 7°) compared to preoperative 5,8° (0° to 14°). The assessment of the proximal tibial varus angle resulted in an angle of 3,8° (1 to 7°). The measurements on deep flexion radiographs are not yet available. Discussion and Conclusion. Until now we had no dislocation of the bearing in our series, but further follow-up is needed. The preliminary clinical results are already promising and display no early complications needing further operations. By anatomical placement of the femoral component the height of the lateral joint line seems to be respected, confirmed by a nearly correct proximal tibial varus angle in all cases. An increased proximal tibial varus angle can also be avoided by minimizing damage to the lateral soft tissues during surgery and so not over-tighten the knee. Therefore the popliteus tendon should stay intact. The elevated posterior translation, as seen in the recent kinematic studies of the lateral Oxford UKP can perhaps also be reduced by respecting those soft tissues


Orthopaedic Proceedings
Vol. 85-B, Issue SUPP_I | Pages 29 - 29
1 Jan 2003
Price A Svard U
Full Access

To report a 15-year survival analysis of the Oxford Medial Unicompartmental Knee Arthroplasty (Oxford UKA) in an independent series. We report the results of a series of 420 Oxford UKAs performed between 1983 and 2000. Indications for surgery were primary antero-medial osteoarthritis of the knee with an intact ACL, correctable varus deformity of < 15° and < 15° fixed flexion deformity. The state of the patello-femoral joint was not used as a selection criterion. Patients were contacted by a postal questionnaire or by telephone. The outcome of all 420 knees was established, with none lost to follow-up. Seventy-six knees were in patients who had died and the state of each arthroplasty was determined from hospital and GP records. Seventeen patients (4%) had required revision. Indications for revision were lateral compartment arthrosis (7), component loosening (4), bearing dislocation (4) and infection (2). There were no failures for polyethylene wear. Cumulative survival at 15 years was 94.3% [95% CI 3.8%]. The worst case scenario was 94.3% as none were lost to follow-up. The results from an independent series are important, as they avoid bias. The 15-year results of this independent series are better than any other reported series of unicompartmental device at 15 years and as good as the published independent 15 year survival results for total knee arthroplasty. The data illustrates that excellent long-term survival can be achieved with the Oxford UKA, allowing patients to benefit from the advantages that unicompartmental arthroplasty offers. We believe that provided patients are selected appropriately, this device provides the treatment of choice for anteromedial osteoarthritis of the knee


Orthopaedic Proceedings
Vol. 84-B, Issue SUPP_II | Pages 164 - 164
1 Jul 2002
Thompson NW Wilson DS Beverland DE
Full Access

Dislocation of the polyethylene-rotating platform is a recognised complication of LCS knee arthroplasty. We report ten cases of rotating platform dislocation out of 2151 primary total knee arthroplasties (0.5%) performed to date in our unit. Of the ten cases (3 male: 7 female), six patients had a preoperative valgus deformity, two had a varus deformity and the remaining two patients were in neutral alignment, although the wear was predominantly within the lateral compartment. Two patients also had a previous patellectomy on the side of the platform spinout. Of the ten cases, six patients were symptomatic as a result of their platform dislocation. The remaining four patients were asymptomatic and mobilising without any difficulty. In these patients, the dislocated platform was diagnosed on x-ray at outpatient review. Time to detection of the platform dislocation ranged from six days to two years. Three patients required revision of their original insert to a larger, deeper dish insert. Three were managed by open reduction of the original insert. Of the remaining patients, one was managed successfully by closed reduction, one required an arthrodesis and one had the tibial insert cemented to the tibial tray. All patients at latest review have a functional and stable knee joint. In conclusion, we feel that surgical error was to blame for the majority of our ten cases. Furthermore, we emphasise the importance of producing equal and balanced flexion and extension gaps at the time of knee arthroplasty in order to prevent mobile bearing dislocation. A novel technique for reducing a dislocated rotating platform is also described


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_I | Pages 224 - 224
1 Mar 2010
Harnett N Tregonning R Rothwell A Hobbs T
Full Access

To identify frequency and patterns of Oxford Phase 3 Unicompartmental Knee Arthroplasty (UKA) failure in New Zealand through analysis of national primary and revision data. Compare the results of this data with that of total knee arthroplasty and other international joint registers. Retrospective audit examining all Oxford Phase 3 UKAs recorded in the New Zealand National Joint Register from January 2000 to December 2007 were analysed and then statistic al analysis performed to identify patterns of failure and reasons for revision. Two thousand six hundred and twenty Oxford UKAs were performed by 99 Orthopædic Surgeons. The average age was 66.1 years (range 35–94). Osteoarthritis was the primary diagnosis. Mean time to revision 839 days (2.3 years). Revision rate was 5.6% (n=148). The most common reasons for revision were pain (n=61, 41%), aseptic loosening (n=53, 36%), and bearing dislocation (n=16, 11%). Deep infection rate was 0.26% (7/2620) compared with 1.76% of total knee arthroplasties (564/32029). Six surgeons (high use & #8805;10 UKAs/year) performed 699 (26.7%) operations, revision rate 2.6%. Fifty-five surgeons (low use & #8804; two UKA/year) performed 283 (10.8%) operations, revision rate 10.6%. There was a statistically significant difference seen with an inverse relationship between surgeon experience and revision. The revision rate for the Oxford is three, two times greater than TKA. UKA is now decreasing in New Zealand whilst Total Knee Arthroplasty (TKA) continues to increase. The number of is now decreasing in New Zealand whilst Total Knee Arthroplasty (TKA) continues to increase. The number of surgeons using Oxford UKA has increased by 19% but the number of Oxfords being done has fallen by 13%. High use surgeons’ revision rate is now higher than TKA. An inverse relationship between failure and surgeon experience exists which confirms Swedish Knee Arthroplasty register reports. The deep infection rate is less than TKA. Revisions were performed early for unexplained pain in the absence of obvious mechanical failure. This is against generally held wisdom for TKA and may reflect the perception that UKA is easily revised to TKA


Orthopaedic Proceedings
Vol. 86-B, Issue SUPP_I | Pages 14 - 14
1 Jan 2004
Gasparini G Tafuro L Cerciello S Pola E De Santis E
Full Access

Aseptic loosening is one of the most frequent cause of total knee arthroplasty (TKA) failure; it is related to a fatigue-type wear which can rapidly break up a tibial polyethylene (PE) inlay. PE debris production is the result of this wear and depend on contact stress between the components. This crucial parameter is more related to conformity than to load tranfer. That is why mobile bearing TKA seems to represent a valid solution to the PE debris production. In fact this implant offers great tibio-femoral conformity without an increased risk of loosening due to increased axial torque. Mobile bearing TKA also eneables the surgeon to self correct tibial component malrotation. On the other hand this implant could lead to new problems such as bearing dislocation or breakage and a possible new wear pattern at the PE-tibial metal tray interface. We performed 100 consecutive cemented posterior stabilised TKA using randomly in 50 cases a mobile bearing and in 50 cases the same implant with a fixed bearing. The mean follow up was 15 months. The results in mobile bearing group are the following. Hospital for Special Surgery (HSS) score improved from 38 to 91 after the surgery. Preoperative Range of Movement (ROM) was 71 while the post op value was 107. No lucencies > 1 mm were observed. There were no statistically significant differences among the mobile bearing group and the fixed bearing one. Despite our short follow up, this implant offers the same good clinical results if compared to other devices, and allows the surgeons to correct errors in positioning the implant. In future we have to consider that this possibility will lead to an abnormal load stresses distribution and to a higher risk of late loosening


Orthopaedic Proceedings
Vol. 91-B, Issue SUPP_II | Pages 339 - 339
1 May 2009
Tregonning R Rothwell A Hobbs T Hartnett N
Full Access

The purpose of this study was to identify causes of failure and rates of revision of the Oxford prosthesis (OXF) in New Zealand, by reviewing and comparing the uni-compartmental (UKA) and total knee arthroplasty (TKA) data from January 2000 to December 2005, as recorded in the New Zealand National Joint Registry. Eighty one orthopaedic surgeons performed 2006 Oxford UKAs (64% of all UKAs). The revision rate was 4.7%. This compared with a revision rate of 4.8% for all UKAs combined, and 1.6% for TKA. UKA (3122) made up 13% of all knee arthroplasties (24 260). The most common reasons for revision of the OXF were aseptic loosening (45%), unexplained pain (33%) and bearing dislocation (12%). Unexplained pain as the only reason for revision (33%) was significantly different (p = 0.001) from the TKA rate (23%). Deep infection as a cause for revision was 0.20% for the OXF compared with 0.48% for TKA (p=0.07). The patient- generated Oxford scores at six months after operation were rated excellent or very good (Field et al, 2004) in 68% of OXF compared with 62% TKA patients (p = 0.001). Five higher-use OXF surgeons (12 or more/year) performed 25.1% of the operations with a revision rate of 0.99%. Ten high- use surgeons (eight to 11/year) performed 28.1 % of operations with a revision rate 4.6%. Thirty medium-use surgeons (two to seven/year) performed 39.0% of the operations with a revision rate of 6.4%. Thirty-six low-use surgeons (one or less/ year) performed 7.8% of the operations with a revision rate of 8.3%. The difference in revision rate between the higher-use surgeons (one operation/month) and all the other three lower use groups was significant (e.g. p=0.0006 higher/low). The early revision rate for the OXF was 2.9 times greater than that for TKA. However, higher-use surgeons (i.e. those performing one/month or more) had a revision rate comparable to TKA. Deep infection was lower and six month function scores were higher for OXF compared with TKA. Unexplained pain as the only reason for revision was significantly higher for OXF compared with TKA


Orthopaedic Proceedings
Vol. 86-B, Issue SUPP_IV | Pages 468 - 468
1 Apr 2004
Kohan L Cordingley R Ben-Nissan B
Full Access

Introduction This prospective outcome study presents the results and complications of 41 lateral unicompartmental knee joint replacements. Methods One surgeon operated on all the patients in this series. The surgery was performed through minimally invasive techniques wtih the patients being day-stay or overnight stay patients. Assessment was made using SF-36 and WOMAC questionnaires, physical examination, x-ray pre-operatively and at six monthly intervals. Kaplan-Meier survival analysis was carried out. Results Forty-one knees (39 patients) underwent surgery. There were 15 males (average age 64 years) and 26 females (average age 68 years). Mean follow-up time was 3.2 years (max 4.6 years). Of these four were Repicci inlay components, 10 were Repicci onlay components and 28 were Oxford mobile bearing implants. Three patients required reoperation, all having mobile bearings in place. One required revision to total knee replacement for progression of arthritis in the medial compartment, and two for bearing dislocation. The operation consisted of a change of bearing to a thicker one. One of these patients had a further complication, a deep infection which was treated successfully with arthroscopic debridement and antibiotics. Another of the mobile bearing patients had a DVT. WOMAC and SF36 show a reduction in pain and stiffness, and an increase in physical function and quality of life. Kaplan-Meier analysis shows 100% survival of the fixed implants but 96% in the mobile bearing group. However 11% of the mobile bearing group required reoperation. Conclusions Lateral compartment replacement is a technically demanding procedure. This study looks at the early results, and does not examine long-term wear. A significant difference in the complication rates for the different type of implant is noted, with the mobile bearing having a higher reoperation rate. In relation to the conduct of this study, one or more of the authors is in receipt of a research grant from a non-commercial source


Aims

Mobile-bearing unicompartmental knee arthroplasty (UKA) with a flat tibial plateau has not performed well in the lateral compartment, leading to a high rate of dislocation. For this reason, the Domed Lateral UKA with a biconcave bearing was developed. However, medial and lateral tibial plateaus have asymmetric anatomical geometries, with a slightly dished medial and a convex lateral plateau. Therefore, the aim of this study was to evaluate the extent at which the normal knee kinematics were restored with different tibial insert designs using computational simulation.

Methods

We developed three different tibial inserts having flat, conforming, and anatomy-mimetic superior surfaces, whereas the inferior surface in all was designed to be concave to prevent dislocation. Kinematics from four male subjects and one female subject were compared under deep knee bend activity.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVIII | Pages 97 - 97
1 Sep 2012
Dervin G Thurston PR
Full Access

Purpose. Patients with anterior cruciate ligament (ACL) deficiency and symptomatic medial compartment osteoarthritis (OA) present a challenge in management. These are often younger than typical primary OA patients and aspire to remain athletically active beyond simple ADLs. Combined ACL reconstruction and valgus tibial osteotomy (ACLHTO) is a well documented surgical option for patients deemed wither too young or too active for total knee arthroplasty. Unicompartmental knee arthroplasty (UKA) is an established surgical treatment for symptomatic medial osteoarthritis of the knee refractory to conservative management. A commonly cited contraindications is symptomatic ACL deficiency because of previous reports detailing premature failure through loosening of the tibial component. Improved results and endoscopic ACL reconstructive procedures have led to an enticing concept of combining ACL reconstruction with medial unicompartmental knee arthroplasty (ACLUKR) for those ACL-deficient medial osteoarthritic (OA) knees. We sought to compare the outcomes in 2 cohorts of patients who underwent either ACLHTO or ACLUKR for this clinical problem. Method. Patients presenting with symptomatic bone on bone medial compartment OA and concomitant ACL deficiency (clinical or asymptomatic) were evaluated for surgery after exhausting non operative management. Patients who were under 40 or had plans to return to high impact loading sports and/or who had more moderate OA were offered combined ACL – medial opening wedge tibia osteotomy as a surgical procedure of choice. Patients were considered for combined ACL Oxford replacement if they were primarily seeking pain relief and were not engaged or aspiring to return to high impact or pivoting sports. All cases but one were concurrent ACL with either HTO or UKR with autogenous hamstring grafts used in all but 2 cases. Results. Thirty of 34 consecutive cases were available for follow-up for a rate of 88%. The median ages for 14 cases of ACLUKR was 51 (range 43 60) whereas 16 patients with ACLHTO had median age 43.4 (range 32 −59). Median FU was 4.65 yrs with minimum 2 year follow up (range 2–8.3). Three of the cases were revision ACL cases all from previous Gore-Tex reconstructions. All but the first patient had concomitant ACL and Oxford unicompartmental knee replacement at 1 surgical sitting and are the subject of this report. The first patient had an autogenous patella bone tendon bone graft performed 6 months prior to the UKA. There were similar change scores for patients in both groups. For ACLUKR, WOMAC pain improvements from 48.1 10.2 SD preoperatively to 79.0 17 SD postop. For ACLHTO, WOMAC improvements from 55.1 13.2 SD preoperatively to 85.0 17 SD postop. To date there have been no cases of infection or bearing dislocation in the ACLUKR group. One patient in the ACLHTO group was revised to TKR for ongoing pain and postoperative flexion contracture. Patient activities ranged from ambulation to vigorous hiking, tennis, and downhill skiing in the UKR group whereas a few in the ACLHTO group were also running mid distances. Overall satisfaction was similar in both groups. Conclusion. ACL reconstruction can safely be combined with medial UKR. The procedure has been used in younger patients with a view toward bone preservation while anticipating need for future revision. Both cohorts showed similar improvements and can be considered. The choice should be geared toward patient athletic demand. While short term results are encouraging though longer term data are necessary to thoroughly evaluate the role of this procedure in patients with medial compartment osteoarthritis and ACL deficiency


The Bone & Joint Journal
Vol. 102-B, Issue 7 Supple B | Pages 27 - 32
1 Jul 2020
Heckmann N Weitzman DS Jaffri H Berry DJ Springer BD Lieberman JR

Aims

Dual mobility (DM) bearings are an attractive treatment option to obtain hip stability during challenging primary and revision total hip arthroplasty (THA) cases. The purpose of this study was to analyze data submitted to the American Joint Replacement Registry (AJRR) to characterize utilization trends of DM bearings in the USA.

Methods

All primary and revision THA procedures reported to AJRR from 2012 to 2018 were analyzed. Patients of all ages were included and subdivided into DM and traditional bearing surface cohorts. Patient demographics, geographical region, hospital size, and teaching affiliation were assessed. Associations were determined by chi-squared analysis and logistic regression was performed to assess outcome variables.


The Bone & Joint Journal
Vol. 102-B, Issue 3 | Pages 319 - 328
1 Mar 2020
St Mart J de Steiger RN Cuthbert A Donnelly W

Aim

There has been a significant reduction in unicompartmental knee arthroplasty (UKA) procedures recorded in Australia. This follows several national joint registry studies documenting high UKA revision rates when compared to total knee arthroplasty (TKA). With the recent introduction of robotically assisted UKA procedures, it is hoped that outcomes improve. This study examines the cumulative revision rate of UKA procedures implanted with a newly introduced robotic system and compares the results to one of the best performing non-robotically assisted UKA prostheses, as well as all other non-robotically assisted UKA procedures.

Methods

Data from the Australian Orthopaedic Association National Joint Arthroplasty Registry (AOANJRR) for all UKA procedures performed for osteoarthritis (OA) between 2015 and 2018 were analyzed. Procedures using the Restoris MCK UKA prosthesis implanted using the Mako Robotic-Arm Assisted System were compared to non-robotically assisted Zimmer Unicompartmental High Flex Knee System (ZUK) UKA, a commonly used UKA with previously reported good outcomes and to all other non-robotically assisted UKA procedures using Cox proportional hazard ratios (HRs) and Kaplan-Meier estimates of survivorship.


The Bone & Joint Journal
Vol. 101-B, Issue 2 | Pages 227 - 232
1 Feb 2019
Walker T Rutkowski L Innmann M Panzram B Herre J Gotterbarm T Aldinger PR Merle C

Aims

The treatment of patients with allergies to metal in total joint arthroplasty is an ongoing debate. Possibilities include the use of hypoallergenic prostheses, as well as the use of standard cobalt-chromium (CoCr) alloy. This non-designer study was performed to evaluate the clinical outcome and survival rates of unicondylar knee arthroplasty (UKA) using a standard CoCr alloy in patients reporting signs of a hypersensitivity to metal.

Patients and Methods

A consecutive series of patients suitable for UKA were screened for symptoms of metal hypersensitivity by use of a questionnaire. A total of 82 patients out of 1737 patients suitable for medial UKA reporting cutaneous metal hypersensitivity to cobalt, chromium, or nickel were included into this study and prospectively evaluated to determine the functional outcome, possible signs of hypersensitivity, and short-term survivorship at a minimum follow-up of 1.5 years.


The Bone & Joint Journal
Vol. 100-B, Issue 1 | Pages 42 - 49
1 Jan 2018
Walker T Zahn N Bruckner T Streit MR Mohr G Aldinger PR Clarius M Gotterbarm T

Aims

The aim of this independent multicentre study was to assess the mid-term results of mobile bearing unicondylar knee arthroplasty (UKA) for isolated lateral osteoarthritis of the knee joint.

Patients and Methods

We retrospectively evaluated 363 consecutive, lateral UKAs (346 patients) performed using the Oxford domed lateral prosthesis undertaken in three high-volume knee arthroplasty centres between 2006 and 2014. Mean age of the patients at surgery was 65 years (36 to 88) with a mean final follow-up of 37 months (12 to 93)


Bone & Joint 360
Vol. 7, Issue 6 | Pages 15 - 18
1 Dec 2018


The Bone & Joint Journal
Vol. 100-B, Issue 10 | Pages 1352 - 1358
1 Oct 2018
Clough TM Alvi F Majeed H

Aims

Total ankle arthroplasty (TAA) surgery is complex and attracts a wide variety of complications. The literature lacks consistency in reporting adverse events and complications. The aim of this article is to provide a comprehensive analysis of each of these complications from a literature review, and to compare them with rates from our Unit, to aid clinicians with the process of informed consent.

Patients and Methods

A total of 278 consecutive total ankle arthroplasties (251 patients), performed by four surgeons over a six-year period in Wrightington Hospital (Wigan, United Kingdom) were prospectively reviewed. There were 143 men and 108 women with a mean age of 64 years (41 to 86). The data were recorded on each follow-up visit. Any complications either during initial hospital stay or subsequently reported on follow-ups were recorded, investigated, monitored, and treated as warranted. Literature search included the studies reporting the outcomes and complications of TAA implants.


The Bone & Joint Journal
Vol. 101-B, Issue 1 | Pages 15 - 21
1 Jan 2019
Kelly MJ Holton AE Cassar-Gheiti AJ Hanna SA Quinlan JF Molony DC

Aims

The glenohumeral joint is the most frequently dislocated articulation, but possibly due to the lower prevalence of posterior shoulder dislocations, approximately 50% to 79% of posterior glenohumeral dislocations are missed at initial presentation. The aim of this study was to systematically evaluate the most recent evidence involving the aetiology of posterior glenohumeral dislocations, as well as the diagnosis and treatment.

Materials and Methods

A systematic search was conducted using PubMed (MEDLINE), Web of Science, Embase, and Cochrane (January 1997 to September 2017), with references from articles also evaluated. Studies reporting patients who experienced an acute posterior glenohumeral joint subluxation and/or dislocation, as well as the aetiology of posterior glenohumeral dislocations, were included.


The Bone & Joint Journal
Vol. 97-B, Issue 10_Supple_A | Pages 9 - 15
1 Oct 2015
Parratte S Ollivier M Lunebourg A Abdel MP Argenson J

Partial knee arthroplasty (PKA), either medial or lateral unicompartmental knee artroplasty (UKA) or patellofemoral arthroplasty (PFA) are a good option in suitable patients and have the advantages of reduced operative trauma, preservation of both cruciate ligaments and bone stock, and restoration of normal kinematics within the knee joint. However, questions remain concerning long-term survival. The goal of this review article was to present the long-term results of medial and lateral UKA, PFA and combined compartmental arthroplasty for multicompartmental disease. Medium- and long-term studies suggest reasonable outcomes at ten years with survival greater than 95% in UKA performed for medial osteoarthritis or osteonecrosis, and similarly for lateral UKA, particularly when fixed-bearing implants are used. Disappointing long-term outcomes have been observed with the first generation of patellofemoral implants, as well as early Bi-Uni (ie, combined medial and lateral UKA) or Bicompartmental (combined UKA and PFA) implants due to design and fixation issues. Promising short- and med-term results with the newer generations of PFAs and bicompartmental arthroplasties will require long-term confirmation.

Cite this article: Bone Joint J 2015;97-B(10 Suppl A):9–15.


The Bone & Joint Journal
Vol. 99-B, Issue 5 | Pages 623 - 631
1 May 2017
Blaney J Harty H Doran E O’Brien S Hill J Dobie I Beverland D

Aims

Our aim was to examine the clinical and radiographic outcomes in 257 consecutive Oxford unicompartmental knee arthroplasties (OUKAs) (238 patients), five years post-operatively.

Patients and Methods

A retrospective evaluation was undertaken of patients treated between April 2008 and October 2010 in a regional centre by two non-designing surgeons with no previous experience of UKAs. The Oxford Knee Scores (OKSs) were recorded and fluoroscopically aligned radiographs were assessed post-operatively at one and five years.


Bone & Joint Research
Vol. 6, Issue 8 | Pages 522 - 529
1 Aug 2017
Ali AM Newman SDS Hooper PA Davies CM Cobb JP

Objectives

Unicompartmental knee arthroplasty (UKA) is a demanding procedure, with tibial component subsidence or pain from high tibial strain being potential causes of revision. The optimal position in terms of load transfer has not been documented for lateral UKA. Our aim was to determine the effect of tibial component position on proximal tibial strain.

Methods

A total of 16 composite tibias were implanted with an Oxford Domed Lateral Partial Knee implant using cutting guides to define tibial slope and resection depth. Four implant positions were assessed: standard (5° posterior slope); 10° posterior slope; 5° reverse tibial slope; and 4 mm increased tibial resection. Using an electrodynamic axial-torsional materials testing machine (Instron 5565), a compressive load of 1.5 kN was applied at 60 N/s on a meniscal bearing via a matching femoral component. Tibial strain beneath the implant was measured using a calibrated Digital Image Correlation system.


The Bone & Joint Journal
Vol. 96-B, Issue 1 | Pages 59 - 64
1 Jan 2014
Weston-Simons JS Pandit H Kendrick BJL Jenkins C Barker K Dodd CAF Murray DW

Mobile-bearing unicompartmental knee replacements (UKRs) with a flat tibial plateau have not performed well in the lateral compartment, owing to a high dislocation rate. This led to the development of the Domed Lateral Oxford UKR (Domed OUKR) with a biconcave bearing. The aim of this study was to assess the survival and clinical outcomes of the Domed OUKR in a large patient cohort in the medium term.

We prospectively evaluated 265 consecutive knees with isolated disease of the lateral compartment and a mean age at surgery of 64 years (32 to 90). At a mean follow-up of four years (sd 2.2, (0.5 to 8.3)) the mean Oxford knee score was 40 out of 48 (sd 7.4). A total of 12 knees (4.5%) had re-operations, of which four (1.5%) were for dislocation. All dislocations occurred in the first two years. Two (0.8%) were secondary to significant trauma that resulted in ruptured ligaments, and two (0.8%) were spontaneous. In four patients (1.5%) the UKR was converted to a primary TKR. Survival at eight years, with failure defined as any revision, was 92.1% (95% confidence interval 81.3 to 100).

The Domed Lateral OUKR gives good clinical outcomes, low re-operation and revision rates and a low dislocation rate in patients with isolated lateral compartmental disease, in the hands of the designer surgeons.

Cite this article: Bone Joint J 2014;96-B:59–64.


The Bone & Joint Journal
Vol. 99-B, Issue 1_Supple_A | Pages 65 - 69
1 Jan 2017
Thienpont E

Objectives

Unicompartmental knee arthroplasty (UKA) is a potential treatment for isolated bone on bone osteoarthritis when limited to a single compartment. The risk for revision of UKA is three times higher than for total knee arthroplasty (TKA). The aim of this review was to discuss the different revision options after UKA failure.

Materials and Methods

A search was performed for English language articles published between 2006 and 2016. After reviewing titles and abstracts, 105 papers were selected for further analysis. Of these, 39 papers were deemed to contain clinically relevant data to be included in this review.


Bone & Joint 360
Vol. 3, Issue 5 | Pages 12 - 16
1 Oct 2014

The October 2014 Knee Roundup360 looks at: microfracture equivalent to OATS; examination better than MRI in predicting hamstrings re-injury; a second view on return to play with hamstrings injuries; dislocation risks in the Oxford Unicompartmental Knee; what about the tibia?; getting on top of lateral facet pain post TKR; readmission in TKR; patient-specific instrumentation; treating infrapatellar saphenous neuralgia; and arthroscopy in the middle-aged.


The Bone & Joint Journal
Vol. 98-B, Issue 10_Supple_B | Pages 34 - 40
1 Oct 2016
Emerson RH Alnachoukati O Barrington J Ennin K

Aims

Approved by the Food and Drug Administration in 2004, the Phase III Oxford Medial Partial Knee is used to treat anteromedial osteoarthritis (AMOA) in patients with an intact anterior cruciate ligament. This unicompartmental knee arthroplasty (UKA) is relatively new in the United States, and therefore long-term American results are lacking.

Patients and Methods

This is a single surgeon, retrospective study based on prospectively collected data, analysing a consecutive series of primary UKAs using the Phase III mobile-bearing Oxford Knee and Phase III instrumentation.

Between July 2004 and December 2006, the senior author (RHE) carried out a medial UKA in 173 patients (213 knees) for anteromedial osteoarthritis or avascular necrosis (AVN).

A total of 95 patients were men and 78 were women. Their mean age at surgery was 67 years (38 to 89) and mean body mass index 29.87 kg/m2 (17 to 62).

The mean follow-up was ten years (4 to 11).


The Bone & Joint Journal
Vol. 98-B, Issue 10_Supple_B | Pages 41 - 47
1 Oct 2016
Lisowski LA Meijer LI Bekerom MPJVD Pilot P Lisowski AE

Aims

The interest in unicompartmental knee arthroplasty (UKA) for medial osteoarthritis has increased rapidly but the long-term follow-up of the Oxford UKAs has yet to be analysed in non-designer centres. We have examined our ten- to 15-year clinical and radiological follow-up data for the Oxford Phase III UKAs.

Patients and Methods

Between January 1999 and January 2005 a total of 138 consecutive Oxford Phase III arthroplasties were performed by a single surgeon in 129 patients for medial compartment osteoarthritis (71 right and 67 left knees, mean age 72.0 years (47 to 91), mean body mass index 28.2 (20.7 to 52.2)). Both clinical data and radiographs were prospectively recorded and obtained at intervals. Of the 129 patients, 32 patients (32 knees) died, ten patients (12 knees) were not able to take part in the final clinical and radiological assessment due to physical and mental conditions, but via telephone interview it was confirmed that none of these ten patients (12 knees) had a revision of the knee arthroplasty. One patient (two knees) was lost to follow-up.


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 5 | Pages 622 - 628
1 May 2011
Pandit H Jenkins C Gill HS Smith G Price AJ Dodd CAF Murray DW

The contraindications for unicompartmental knee replacement (UKR) remain controversial. The views of many surgeons are based on Kozinn and Scott’s 1989 publication which stated that patients who weighed more than 82 kg, were younger than 60 years, undertook heavy labour, had exposed bone in the patellofemoral joint or chondrocalcinosis, were not ideal candidates for UKR. Our aim was to determine whether these potential contraindications should apply to patients with a mobile-bearing UKR. In order to do this the outcome of patients with these potential contraindications was compared with that of patients without the contraindications in a prospective series of 1000 UKRs. The outcome was assessed using the Oxford knee score, the American Knee Society score, the Tegner activity score, revision rate and survival.

The clinical outcome of patients with each of the potential contraindications was similar to or better than those without each contraindication. Overall, 678 UKRs (68%) were performed in patients who had at least one potential contraindication and only 322 (32%) in patients deemed to be ideal. The survival at ten years was 97.0% (95% confidence interval 93.4 to 100.0) for those with potential contraindications and 93.6% (95% confidence interval 87.2 to 100.0) in the ideal patients.

We conclude that the thresholds proposed by Kozinn and Scott using weight, age, activity, the state of the patellofemoral joint and chondrocalcinosis should not be considered to be contraindications for the use of the Oxford UKR.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 8 | Pages 1071 - 1076
1 Aug 2012
Lim H Bae J Song S Kim S

Medium-term survivorship of the Oxford phase 3 unicompartmental knee replacement (UKR) has not yet been established in an Asian population. We prospectively evaluated the outcome of 400 phase 3 Oxford UKRs in 320 Korean patients with a mean age at the time of operation of 69 years (48 to 82). The mean follow-up was 5.2 years (1 to 10). Clinical and radiological assessment was carried out pre- and post-operatively. At five years, the mean Knee Society knee and functional scores had increased significantly from 56.2 (30 to 91) pre-operatively to 87.2 (59 to 98) (p = 0.034) and from 59.2 (30 to 93) to 88.3 (50 to 100) (p = 0.021), respectively. The Oxford knee score increased from a mean of 25.8 (12 to 39) pre-operatively to 39.8 (25 to 58) at five years (p = 0.038). The ten-year survival rate was 94% (95% confidence interval 90.1 to 98.0). A total of 14 UKRs (3.5%) required revision. The most common reason for revision was dislocation of the bearing in 12 (3%). Conversion to a total knee replacement was required in two patients who developed osteoarthritis of the lateral compartment.

This is the largest published series of UKR in Korean patients. It shows that the mid-term results after a minimally invasive Oxford phase 3 UKR can yield satisfactory clinical and functional results in this group of patients.


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 2 | Pages 198 - 204
1 Feb 2011
Pandit H Jenkins C Gill HS Barker K Dodd CAF Murray DW

This prospective study describes the outcome of the first 1000 phase 3 Oxford medial unicompartmental knee replacements (UKRs) implanted using a minimally invasive surgical approach for the recommended indications by two surgeons and followed up independently. The mean follow-up was 5.6 years (1 to 11) with 547 knees having a minimum follow-up of five years. At five years their mean Oxford knee score was 41.3 (sd 7.2), the mean American Knee Society Objective Score 86.4 (sd 13.4), mean American Knee Society Functional Score 86.1 (sd 16.6), mean Tegner activity score 2.8 (sd 1.1). For the entire cohort, the mean maximum flexion was 130° at the time of final review.

The incidence of implant-related re-operations was 2.9%; of these 29 re-operations two were revisions requiring revision knee replacement components with stems and wedges, 17 were conversions to a primary total knee replacement, six were open reductions for dislocation of the bearing, three were secondary lateral UKRs and one was revision of a tibial component. The most common reason for further surgical intervention was progression of arthritis in the lateral compartment (0.9%), followed by dislocation of the bearing (0.6%) and revision for unexplained pain (0.6%). If all implant-related re-operations are considered failures, the ten-year survival rate was 96% (95% confidence interval, 92.5 to 99.5). If only revisions requiring revision components are considered failures the ten-year survival rate is 99.8% (confidence interval 99 to 100).

This is the largest published series of UKRs implanted through a minimally invasive surgical approach and with ten-year survival data. The survival rates are similar to those obtained with a standard open approach whereas the function is better. This demonstrates the effectiveness and safety of a minimally invasive surgical approach for implanting the Oxford UKR.


The Bone & Joint Journal
Vol. 97-B, Issue 10 | Pages 1358 - 1363
1 Oct 2015
Hooper N Snell D Hooper G Maxwell R Frampton C

This study reports on the first 150 consecutive Oxford cementless unicompartmental knee arthroplasties (UKA) performed in an independent centre (126 patients). All eligible patients had functional scores (Oxford knee score and high activity arthroplasty score) recorded pre-operatively and at two- and five-years of follow-up. Fluoroscopically aligned radiographs were taken at five years and analysed for any evidence of radiolucent lines (RLLs), subsidence or loosening. The mean age of the cohort was 63.6 years (39 to 86) with 81 (53.1%) males. Excellent functional scores were maintained at five years and there were no progressive RLLs demonstrated on radiographs. Two patients underwent revision to a total knee arthroplasty giving a revision rate of 0.23/100 (95% confidence interval 0.03 to 0.84) component years with overall component survivorship of 98.7% at five years. There were a further four patients who underwent further surgery on the same knee, two underwent bearing exchanges for dislocation and two underwent lateral UKAs for disease progression. This was a marked improvement from other UKAs reported in New Zealand Joint Registry data and supports the designing centre’s early results.

Cite this article: Bone Joint J 2015;97-B:1358–63.


The Bone & Joint Journal
Vol. 97-B, Issue 11 | Pages 1493 - 1499
1 Nov 2015
Pandit H Hamilton TW Jenkins C Mellon SJ Dodd CAF Murray DW

This prospective study reports the 15-year survival and ten-year functional outcome of a consecutive series of 1000 minimally invasive Phase 3 Oxford medial UKAs (818 patients, 393 men, 48%, 425 women, 52%, mean age 66 years; 32 to 88). These were implanted by two surgeons involved with the design of the prosthesis to treat anteromedial osteoarthritis and spontaneous osteonecrosis of the knee, which are recommended indications. Patients were prospectively identified and followed up independently for a mean of 10.3 years (5.3 to 16.6).

At ten years, the mean Oxford Knee Score was 40 (standard deviation (sd) 9; 2 to 48): 79% of knees (349) had an excellent or good outcome. There were 52 implant-related re-operations at a mean of 5.5 years (0.2 to 14.7). The most common reasons for re-operation were arthritis in the lateral compartment (2.5%, 25 knees), bearing dislocation (0.7%, seven knees) and unexplained pain (0.7%, seven knees). When all implant-related re-operations were considered as failures, the ten-year rate of survival was 94% (95% confidence interval (CI) 92 to 96) and the 15-year survival rate 91% (CI 83 to 98). When failure of the implant was the endpoint the 15-year survival was 99% (CI 96 to 100).

This is the only large series of minimally invasive UKAs with 15-year survival data. The results support the continued use of minimally invasive UKA for the recommended indications.

Cite this article: Bone Joint J 2015;97-B:1493–99.


The Bone & Joint Journal
Vol. 97-B, Issue 2 | Pages 185 - 191
1 Feb 2015
Kendrick BJL Kaptein BL Valstar ER Gill HS Jackson WFM Dodd CAF Price AJ Murray DW

The most common reasons for revision of unicompartmental knee arthroplasty (UKA) are loosening and pain. Cementless components may reduce the revision rate. The aim of this study was to compare the fixation and clinical outcome of cementless and cemented Oxford UKAs.

A total of 43 patients were randomised to receive either a cemented or a cementless Oxford UKA and were followed for two years with radiostereometric analysis (RSA), radiographs aligned with the bone–implant interfaces and clinical scores.

The femoral components migrated significantly during the first year (mean 0.2 mm) but not during the second. There was no significant difference in the extent of migration between cemented and cementless femoral components in either the first or the second year. In the first year the cementless tibial components subsided significantly more than the cemented components (mean 0.28 mm (sd 0.17) vs. 0.09 mm (sd 0.19 mm)). In the second year, although there was a small amount of subsidence (mean 0.05 mm) there was no significant difference (p = 0.92) between cemented and cementless tibial components. There were no femoral radiolucencies. Tibial radiolucencies were narrow (< 1 mm) and were significantly (p = 0.02) less common with cementless (6 of 21) than cemented (13 of 21) components at two years. There were no complete radiolucencies with cementless components, whereas five of 21 (24%) cemented components had complete radiolucencies. The clinical scores at two years were not significantly different (p = 0.20).

As second-year migration is predictive of subsequent loosening, and as radiolucency is suggestive of reduced implant–bone contact, these data suggest that fixation of the cementless components is at least as good as, if not better than, that of cemented devices.

Cite this article: Bone Joint J 2015; 97-B:185–91.


The Bone & Joint Journal
Vol. 96-B, Issue 10 | Pages 1359 - 1365
1 Oct 2014
Large R Tambe A Cresswell T Espag M Clark DI

Medium-term results of the Discovery elbow replacement are presented. We reviewed 51 consecutive primary Discovery total elbow replacements (TERs) implanted in 48 patients. The mean age of the patients was 69.2 years (49 to 92), there were 19 males and 32 females (37%:63%) The mean follow-up was 40.6 months (24 to 69). A total of six patients were lost to follow-up. Statistically significant improvements in range movement and Oxford Elbow Score were found (p < 0.001). Radiolucent lines were much more common in, and aseptic loosening was exclusive to, the humeral component. Kaplan–Meier survivorship at five years was 92.2% (95% CI 74.5% to 96.4%) for aseptic loosening. In four TERs, periprosthetic infection occurred resulting in failure. A statistically significant association between infection and increased BMI was found (p = 0.0268). Triceps failure was more frequent after the Mayo surgical approach and TER performed after previous trauma surgery. No failures of the implant were noted.

Our comparison shows that the Discovery has early clinical results that are similar to other semi-constrained TERs. We found continued radiological surveillance with particular focus on humeral lucency is warranted and has not previously been reported. Despite advances in the design of total elbow replacement prostheses, rates of complication remain high.

Cite this article: Bone Joint J 2014;96-B:1359–65


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 12 | Pages 1597 - 1601
1 Dec 2007
Beard DJ Pandit H Gill HS Hollinghurst D Dodd CAF Murray DW

Patellofemoral joint degeneration is often considered a contraindication to medial unicompartmental knee replacement. We examined the validity of this preconception using information gathered prospectively on the intra-operative status of the patellofemoral joint in 824 knees in 793 consecutive patients who underwent Oxford unicondylar knee replacement for anteromedial osteoarthritis. All operations were performed between January 1998 and September 2005. A five-point grading system classified degeneration of the patellofemoral joint from none to full-thickness cartilage loss. A subclassification of the presence or absence of any full-thickness cartilage loss was subsequently performed to test selected hypotheses. Outcome was evaluated independently by physiotherapists using the Oxford and the American Knee Society Scores with a minimum follow-up of one year.

Full-thickness cartilage loss on the trochlear surface was observed in 100 of 785 knees (13%), on the medial facet of the patella in 69 of 782 knees (9%) and on the lateral facet in 29 of 784 knees (4%). Full-thickness cartilage loss at any location was seen in 128 knees (16%) and did not produce a significantly worse outcome than those with a normal or near-normal joint surface. The severity of the degeneration at any of the intra-articular locations also had no influence on outcome.

We concluded that, provided there is not bone loss and grooving of the lateral facet, damage to the articular cartilage of the patellofemoral joint to the extent of full-thickness cartilage loss is not a contraindication to the Oxford mobile-bearing unicompartmental knee replacement.


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 11 | Pages 1488 - 1492
1 Nov 2005
Price AJ Dodd CAF Svard UGC Murray DW

We present a comparison of the results of the Oxford unicompartmental knee arthroplasty in patients younger and older than 60 years of age. The ten-year all-cause survival of the < 60 years of age group (52) was 91% (95% confidence interval (CI) 12), while in the ≥ 60 years of age group (512), the figure was 96% (95% CI 3). For the younger group, the mean Hospital for Special Surgery score at ten-year follow-up (n = 21) was 94 of 100, compared with a mean of 86 of 100 for the older group (n = 135). The results show that the Oxford unicompartmental arthroplasty can achieve ten-year results that are comparable to total knee arthroplasty in patients < 60 years of age. We conclude that for patients aged over 50, age should not be considered a contraindication for this procedure.


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 1 | Pages 54 - 60
1 Jan 2006
Pandit H Jenkins C Barker K Dodd CAF Murray DW

This prospective study describes the complications and survival of the first 688 Phase 3 Oxford medial unicompartmental knee replacements implanted using a minimally-invasive technique by two surgeons and followed up independently. None was lost to follow-up. We had carried out 132 of the procedures more than five years ago. The clinical assessment of 101 of these which were available for review at five years is also presented.

Nine of the 688 knees were revised: four for infection, three for dislocation of the bearing and two for unexplained pain. A further seven knees (1%) required other procedures: four had a manipulation under anaesthesia, two an arthroscopy and one a debridement for superficial infection. The survival rate at seven years was 97.3% (95% confidence interval 5.3). At five years, 96% of the patients had a good or excellent American Knee Society score, the mean Oxford knee score was 39 and the mean flexion was 133°. This study demonstrates that the minimally-invasive Oxford unicompartmental knee replacement is a reliable and effective procedure.


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 4 | Pages 470 - 475
1 Apr 2011
Kendrick BJL Simpson DJ Kaptein BL Valstar ER Gill HS Murray DW Price AJ

The Oxford unicompartmental knee replacement (UKR) was designed to minimise wear utilising a fully-congruent, mobile, polyethylene bearing. Wear of polyethylene is a significant cause of revision surgery in UKR in the first decade, and the incidence increases in the second decade. Our study used model-based radiostereometric analysis to measure the combined wear of the upper and lower bearing surfaces in 13 medial-compartment Oxford UKRs at a mean of 20.9 years (17.2 to 25.9) post-operatively.

The mean linear penetration of the polyethylene bearing was 1.04 mm (0.307 to 2.15), with a mean annual wear rate of 0.045 mm/year (0.016 to 0.099). The annual wear rate of the phase-2 bearings (mean 0.022 mm/year) was significantly less (p = 0.01) than that of phase-1 bearings (mean 0.07 mm/year).

The linear wear rate of the Oxford UKR remains very low into the third decade. We believe that phase-2 bearings had lower wear rates than phase-1 implants because of the improved bearing design and surgical technique which decreased the incidence of impingement. We conclude that the design of the Oxford UKR gives low rates of wear in the long term.


Bone & Joint 360
Vol. 1, Issue 6 | Pages 12 - 14
1 Dec 2012

The December 2012 Knee Roundup360 looks at: the demand for knee replacement; a Japanese knee outcome score; smoking and TKR; coronal alignment as a determinant of outcome in TKR; fixed flexion; MRI detected knee lesions; and lateral domed Oxford unicompartmental knee replacements.


The Bone & Joint Journal
Vol. 95-B, Issue 2 | Pages 181 - 187
1 Feb 2013
Liddle AD Pandit H O’Brien S Doran E Penny ID Hooper GJ Burn PJ Dodd CAF Beverland DE Maxwell AR Murray DW

The Cementless Oxford Unicompartmental Knee Replacement (OUKR) was developed to address problems related to cementation, and has been demonstrated in a randomised study to have similar clinical outcomes with fewer radiolucencies than observed with the cemented device. However, before its widespread use it is necessary to clarify contraindications and assess the complications. This requires a larger study than any previously published.

We present a prospective multicentre series of 1000 cementless OUKRs in 881 patients at a minimum follow-up of one year. All patients had radiological assessment aligned to the bone–implant interfaces and clinical scores. Analysis was performed at a mean of 38.2 months (19 to 88) following surgery. A total of 17 patients died (comprising 19 knees (1.9%)), none as a result of surgery; there were no tibial or femoral loosenings. A total of 19 knees (1.9%) had significant implant-related complications or required revision. Implant survival at six years was 97.2%, and there was a partial radiolucency at the bone–implant interface in 72 knees (8.9%), with no complete radiolucencies. There was no significant increase in complication rate compared with cemented fixation (p = 0.87), and no specific contraindications to cementless fixation were identified.

Cementless OUKR appears to be safe and reproducible in patients with end-stage anteromedial osteoarthritis of the knee, with radiological evidence of improved fixation compared with previous reports using cemented fixation.

Cite this article: Bone Joint J 2013;95-B:181–7.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 9 | Pages 1216 - 1220
1 Sep 2012
Weston-Simons JS Pandit H Jenkins C Jackson WFM Price AJ Gill HS Dodd CAF Murray DW

The Oxford unicompartmental knee replacement (UKR) is an established treatment option in the management of symptomatic end-stage medial compartmental osteoarthritis (MCOA), which works well in the young and active patient. However, previous studies have shown that it is reliable only in the presence of a functionally intact anterior cruciate ligament (ACL). This review reports the outcomes, at a mean of five years and a maximum of ten years, of 52 consecutive patients with a mean age of 51 years (36 to 57) who underwent staged or simultaneous ACL reconstruction and Oxford UKR. At the last follow-up (with one patient lost to follow-up), the mean Oxford knee score was 41 (sd 6.3; 17 to 48). Two patients required conversion to TKR: one for progression of lateral compartment osteoarthritis and one for infection. Implant survival at five years was 93% (95% CI 83 to 100). All but one patient reported being satisfied with the procedure. The outcome was not significantly influenced by age, gender, femoral or tibial tunnel placement, or whether the procedure was undertaken at one- or two-stages.

In summary, ACL reconstruction and Oxford UKR gives good results in patients with end-stage MCOA secondary to ACL deficiency.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 10 | Pages 1366 - 1371
1 Oct 2012
Pijls BG Valstar ER Kaptein BL Nelissen RGHH

This single-blinded randomised controlled trial investigated whether one design of mobile-bearing (MB) total knee replacement (TKR) has any advantage over a fixed-bearing (FB) design on long-term fixation as measured by radiostereometry. The amount of wear underneath the mobile bearing was also evaluated. A series of 42 knees was randomised to MB or FB tibial components with appropriate polyethylene inserts and followed for between ten and 12 years, or until the death of the patient. The polyethylene in the MB group was superior in that it was gamma-irradiated in inert gas and was calcium-stearate free; the polyethylene in the FB group was gamma-irradiated in air and contained calcium stearate. In theory this should be advantageous to the wear rate of the MB group. At final follow-up the overall mean migration was 0.75 mm (sd 0.76) in the MB group and 0.66 mm (sd 0.4) in the FB group, with the FB group demonstrating more posterior tilt and the MB group more internal rotation. In the FB group there was one revision for aseptic loosening, but none in the MB group. There were no significant differences in clinical or radiological scores.

For the MB group, the mean linear wear rate on the under-surface was 0.026 mm/year (sd 0.014). This was significantly smaller than the wear rate of 0.11 mm/year (sd 0.06) in the MB between femur and polyethylene (p < 0.001). Nevertheless, even in a best-case setting the mobile bearings of this TKR design had no apparent advantage in terms of fixation over the FB knee prosthesis at ten to 12 years. The wear underneath the mobile bearing was small and is unlikely to be clinically relevant.


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 6 | Pages 777 - 781
1 Jun 2011
Kalra S Smith TO Berko B Walton NP

The Oxford unicompartmental knee replacement gives good results in patients with symptomatic osteoarthritis of the medial compartment. Previous studies have suggested that the presence of radiolucent lines (RLLs) does not reflect a poor outcome in such patients. However, the reliability and validity of this assessment have not been determined. Our aim was to assess the intra- and interobserver reliability and the sensitivity and specificity of the assessment of RLLs around both tibial and femoral components using standard radiographs.

Two reviewers assessed the radiographs of 45 patients who had loosening of the tibial or femoral component confirmed at revision surgery and compared them with those of a series of 45 asymptomatic patients matched for age and gender.

The results suggested that, using standard radiographs, tibial RLLs were 63.6% sensitive and 94.4% specific and femoral RLLs 63.9% sensitive and 72.7% specific for loosening. Overall intra- and interobserver reliability was highly variable, but zonal analysis showed that lucency at the tip of the femoral peg was significantly associated with loosening of the femoral component.

Fluoroscopically guided radiographs may improve the zonal reliability of the assessment of RLLs, but further independent and comparative studies are required. In the meantime, the innocence of the physiological RLLs detected by standard radiographs should be viewed with caution.


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 4 | Pages 508 - 512
1 Apr 2010
Pearse AJ Hooper GJ Rothwell A Frampton C

We reviewed the rate of revision of unicompartmental knee replacements (UKR) from the New Zealand Joint Registry between 1999 and 2008. There were 4284 UKRs, of which 236 required revision, 205 to a total knee replacement (U2T) and 31 to a further unicompartmental knee replacement (U2U). We used these data to establish whether the survival and functional outcome for revised UKRs were comparable with those of primary total knee replacement (TKR). The rate of revision for the U2T cohort was four times higher than that for a primary TKR (1.97 vs 0.48; p < 0.05). The mean Oxford Knee Score was also significantly worse in the U2T group than that of the primary TKR group (30.02 vs 37.16; p < 0.01). The rate of revision for conversion of a failed UKR to a further UKR (U2U cohort) was 13 times higher than that for a primary TKR.

The poor outcome of a UKR converted to a primary TKR compared with a primary TKR should contra-indicate the use of a UKR as a more conservative procedure in the younger patient.


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 3 | Pages 413 - 418
1 Mar 2010
Rothwell AG Hooper GJ Hobbs A Frampton CM

We analysed data from the Oxford hip and knee questionnaires collected by the New Zealand Joint Registry at six months and five years after joint replacement, to determine if there was any relationship between the scores and the risk of early revision. Logistic regression of the six-month scores indicated that for every one-unit decrease in the Oxford score, the risk of revision within two years increased by 9.7% for total hip replacement (THR), 9.9% for total knee replacement (TKR) and 12.0% for unicompartmental knee replacement (UKR). Our findings showed that 70% of the revisions within two years for TKR and 67% for THR and UKR would have been captured by monitoring the lowest 22%, 28% and 28%, respectively, of the Oxford scores. When analysed using the Kalairajah classification a score of < 27 (poor) was associated with a risk of revision within two years of 7.6% for THR, 7.0% for TKR and 24.3% for UKR, compared with risks of 0.7%, 0.7% and 1.8%, respectively, for scores > 34 (good or excellent).

Our study confirms that the Oxford hip and knee scores at six months are useful predictors of early revision after THR and TKR and we recommend their use for the monitoring of the outcome and potential failure in these patients.


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 8 | Pages 1032 - 1038
1 Aug 2008
Cobb JP Dixon H Dandachli W Iranpour F

The rotational alignment of the tibia is an unresolved issue in knee replacement. A poor functional outcome may be due to malrotation of the tibial component. Our aim was to find a reliable method for positioning the tibial component in knee replacement.

CT scans of 19 knees were reconstructed in three dimensions and orientated vertically. An axial plane was identified 20 mm below the tibial spines. The centre of each tibial condyle was calculated from ten points taken round the condylar cortex. The tibial tubercle centre was also generated as the centre of the circle which best fitted eight points on the outside of the tubercle in an axial plane at the level of its most prominent point.

The derived points were identified by three observers with errors of 0.6 mm to 1 mm. The medial and lateral tibial centres were constant features (radius 24 mm (sd 3), and 22 mm (sd 3), respectively). An anatomical axis was created perpendicular to the line joining these two points. The tubercle centre was found to be 20 mm (sd 7) lateral to the centre of the medial tibial condyle. Compared with this axis, an axis perpendicular to the posterior condylar axis was internally rotated by 6° (sd 3). An axis based on the tibial tubercle and the tibial spines was also internally rotated by 5° (sd 10).

Alignment of the knee when based on this anatomical axis was more reliable than either the posterior surfaces or any axis involving the tubercle which was the least reliable landmark in the region.


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 10 | Pages 1317 - 1323
1 Oct 2007
Kim Y Yoon S Kim J

We compared the results of 146 patients who received an anatomic modular knee fixed-bearing total knee replacement (TKR) in one knee and a low contact stress rotating platform mobile-bearing TKR in the other. There were 138 women and eight men with a mean age of 69.8 years (42 to 80). The mean follow-up was 13.2 years (11.0 to 14.5). The patients were assessed clinically and radiologically using the rating systems of the Hospital for Special Surgery and the Knee Society at three months, six months, one year, and annually thereafter.

The assessment scores of both rating systems pre-operatively and at the final review did not show any statistically significant differences between the two designs of implant. In the anatomic modular knee group, one knee was revised because of aseptic loosening of the tibial component and one because of infection. In addition, three knees were revised because of wear of the polyethylene tibial bearing. In the low contact stress group, two knees were revised because of instability requiring exchange of the polyethylene insert and one because of infection.

The radiological analysis found no statistical difference in the incidence of radiolucent lines at the final review (Student’s t-test, p = 0.08), most of which occurred at tibial zone 1. The Kaplan-Meier survivorship for aseptic loosening of the anatomic modular knee and the low contact stress implants at 14.5 years was 99% and 100%, respectively, with a 95% confidence interval of 94% to 100% for both designs.

We found no evidence of the superiority of one design over the other at long-term follow-up.