header advert
Results 1 - 100 of 342
Results per page:
The Bone & Joint Journal
Vol. 105-B, Issue 11 | Pages 1168 - 1176
1 Nov 2023
Yüksel Y Koster LA Kaptein BL Nelissen RGHH den Hollander P

Aims. Conflicting clinical results are reported for the ATTUNE Total Knee Arthroplasty (TKA). This randomized controlled trial (RCT) evaluated five-year follow-up results comparing cemented ATTUNE and PFC-Sigma cruciate retaining TKAs, analyzing component migration as measured by radiostereometric analysis (RSA), clinical outcomes, patient-reported outcome measures (PROMs), and radiological outcomes. Methods. A total of 74 primary TKAs were included in this single-blind RCT. RSA examinations were performed, and PROMs and clinical outcomes were collected immediate postoperatively, and at three, six, 12, 24, and 60 months’ follow-up. Radiolucent lines (RLLs) were measured in standard anteroposterior radiographs at six weeks, and 12 and 60 months postoperatively. Results. At five-year follow-up, RSA data from 61 patients were available and the mean maximum total point motion (MTPM) of the femoral components were: ATTUNE: 0.96 mm (95% confidence interval (CI) 0.79 to 1.14) and PFC-Sigma 1.37 mm (95% CI 1.18 to 1.59) (p < 0.001). The PFC-Sigma femoral component migrated more in the first postoperative year, but stabilized thereafter. MPTM of the tibial components were comparable at five-year follow-up: ATTUNE 1.12 mm (95% CI 0.95 to 1.31) and PFC-Sigma 1.25 mm (95% CI 1.07 to 1.44) (p = 0.438). RLL at the medial tibial implant-cement interface remained more prevalent for the ATTUNE at five-year follow-up compared to the PFC-Sigma (20% vs 3%). RLL did not progress over time, and varied between patients at different timepoints for both TKA systems. Clinical outcomes and PROMs improved compared with preoperative scores, and were not different between groups. Conclusion. MTPM migration at five-year follow-up of the femoral and tibial component of the ATTUNE were similar and as low as that of the PFC-Sigma. MTPM migration of both knee implants did not significantly change from one year post-surgery, indicating stable fixation. Long-term ATTUNE performance may be expected to be comparable to the clinically well-performing PFC-Sigma. We have not found evidence of increased tibial component migration as measured by RSA to support concerns about cement debonding and a higher risk of aseptic loosening with the ATTUNE TKA. Cite this article: Bone Joint J 2023;105-B(11):1168–1176


Aims. Patient-specific instrumentation of total knee arthroplasty (TKA) is a technique permitting the targeting of individual kinematic alignment, but deviation from a neutral mechanical axis may have implications on implant fixation and therefore survivorship. The primary objective of this randomized controlled study was to compare the fixation of tibial components implanted with patient-specific instrumentation targeting kinematic alignment (KA+PSI) versus components placed using computer-assisted surgery targeting neutral mechanical alignment (MA+CAS). Tibial component migration measured by radiostereometric analysis was the primary outcome measure (compared longitudinally between groups and to published acceptable thresholds). Secondary outcome measures were inducible displacement after one year and patient-reported outcome measures (PROMS) over two years. The secondary objective was to assess the relationship between alignment and both tibial component migration and inducible displacement. Patients and Methods. A total of 47 patients due to undergo TKA were randomized to KA+PSI (n = 24) or MA+CAS (n = 23). In the KA+PSI group, there were 16 female and eight male patients with a mean age of 64 years (. sd. 8). In the MA+CAS group, there were 17 female and six male patients with a mean age of 63 years (. sd. 7). Surgery was performed using cemented, cruciate-retaining Triathlon total knees with patellar resurfacing, and patients were followed up for two years. The effect of alignment on tibial component migration and inducible displacement was analyzed irrespective of study group. Results. There was no difference over two years in longitudinal migration of the tibial component between the KA+PSI and MA+CAS groups (reaching median maximum total point motion migration at two years of 0.40 mm for the KA+PSI group and 0.37 mm for the MA+CAS group, p = 0.82; p = 0.68 adjusted for age, sex, and body mass index (BMI) for all follow-ups). Both groups had mean migrations below acceptable thresholds. There was no difference in inducible displacement (p = 0.34) or PROMS (p = 0.61 for the Oxford Knee Score) between groups. There was no correlation between alignment and tibial component migration or alignment and inducible displacement. These findings support non-neutral alignment as a viable option with this component, with no evidence that it compromises fixation. Conclusion. Kinematic alignment using patient-specific instrumentation in TKA was associated with acceptable tibial component migration, indicating stable fixation. These results are supportive of future investigations of kinematic alignment. Cite this article: Bone Joint J 2019;101-B:929–940


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_9 | Pages 72 - 72
1 Oct 2020
Howard JL Williams HA Lanting BA Teeter MG
Full Access

Background. In recent years, the use of modern cementless implants in total knee arthroplasty has been increasing in popularity. These implants take advantage of new technologies such as additive manufacturing and potentially provide a promising alternative to cemented implant designs. The purpose of this study was to compare implant migration and tibiofemoral contact kinematics of a cementless primary total knee arthroplasty (TKA) implanted using either a gap balancing (GB) or measured resection (MR) surgical technique. Methods. Thirty-nine patients undergoing unilateral TKA were recruited and assigned based on surgeon referral to an arthroplasty surgeon who utilizes either a GB (n = 19) or a MR (n = 20) surgical technique. All patients received an identical fixed-bearing, cruciate-retaining beaded peri-apatite coated cementless femoral component and a pegged highly porous cementless tibial baseplate with a condylar stabilizing tibial insert. Patients underwent a baseline radiostereometric analysis (RSA) exam at two weeks post-operation, with follow-up visits at six weeks, three months, six months, and one year post-operation. Migration including maximum total point motion (MTPM) of the femoral and tibial components was calculated over time. At the one year visit patients also underwent a kinematic exam using the RSA system. Results. Mean MTPM of the tibial component at one year post-operation was not different (mean difference = 0.09 mm, p = 0.980) between the GB group (0.85 ± 0.37 mm) and the MR group (0.94 ± 0.41 mm). Femoral component MTPM at one year post-operation was also not different (mean difference = 0.27 mm, p = 0.463) between the GB group (0.62 ± 0.34 mm) and the MR group (0.89 ± 0.44 mm). Both groups displayed a lateral pivot pattern with similar frequencies of condylar separation. Conclusion. There was no difference in implant migration and kinematics of a single-radius, cruciate retaining cementless TKA performed using a GB or MR surgical technique. The magnitude of migration suggests there is no risk of early loosening. The results provide support for the use of a cementless TKA as a viable alternative to cemented fixation


The Bone & Joint Journal
Vol. 102-B, Issue 12 | Pages 1654 - 1661
1 Dec 2020
Perelgut ME Polus JS Lanting BA Teeter MG

Aims. The direct anterior (DA) approach has been associated with rapid patient recovery after total hip arthroplasty (THA) but may be associated with more frequent femoral complications including implant loosening. The objective of this study was to determine whether the addition of a collar to the femoral stem affects implant migration, patient activity, and patient function following primary THA using the DA approach. Methods. Patients were randomized to either a collared (n = 23) or collarless (n = 26) cementless femoral stem implanted using the DA approach. Canal fill ratio (CFR) was measured on the first postoperative radiographs. Patients underwent a supine radiostereometric analysis (RSA) exam postoperatively on the day of surgery and at two, four, six, 12, 26, and 52 weeks postoperatively. Patient-reported outcome measures (Western Ontario and McMaster Universities Osteoarthritis (WOMAC) Index, the 12-item Short Form Health Survey Mental and Physical Score, and University of California, Los Angeles (UCLA) Activity Score) were measured preoperatively and at each post-surgery clinic visit. Activity and function were also measured as the weekly average step count recorded by an activity tracker, and an instrumented timed up-and-go (TUG) test in clinic, respectively. Results. Comparing the RSA between the day of surgery baseline exam to two weeks postoperatively, subsidence was significantly lower (mean difference 2.23 mm (SD 0.71), p = 0.023) with collared stems, though these patients had a greater CFR (p = 0.048). There was no difference (p = 0.426) in subsidence between stems from a two-week baseline through to one year postoperatively. There were no clinically relevant differences in PROMs; and there was no difference in the change in activity (p = 0.078) or the change in functional capacity (p = 0.664) between the collared stem group and the collarless stem group at any timepoint. Conclusion. Presence of a collar on the femoral stem resulted in reduced subsidence during the first two postoperative weeks following primary THA using the DA approach. However, the clinical implications are unclear, and larger studies examining patient activity and outcomes are required. Cite this article: Bone Joint J 2020;102-B(12):1654–1661


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_1 | Pages 89 - 89
1 Feb 2020
Williams H Howard J Lanting B Teeter M
Full Access

Introduction. A total knee arthroplasty (TKA) is the standard of care treatment for end-stage osteoarthritis (OA) of the knee. Over the last decade, we have observed a change in TKA patient population to include younger patients. This cohort tends to be more active and thus places more stress on the implanted prothesis. Bone cement has historically been used to establish fixation between the implant and host bone, resulting in two interfaces where loosening may occur. Uncemented fixation methods provide a promising alternative to cemented fixation. While vulnerable during the early post-operative period, cementless implants may be better suited to long-term stability in younger patient cohorts. It is currently unknown whether the surgical technique used to implant the cementless prostheses impacts the longevity of the implant. Two different surgical techniques are commonly used by surgeons and may result in different load distribution across the joint, which will affect bone ingrowth. The overall objective of the study is to assess implant migration and in vivo kinematics following cementless TKA. Methods. Thirty-nine patients undergoing a primary unilateral TKA as a result of OA were recruited prior to surgery and randomized to a surgical technique based on surgeon referral. In the gap balancing surgical technique (GB) soft tissues releases are made to restore neutral limb alignment followed by bone cuts (resection) to balance the joint space in flexion and extension. In the measured resection surgical technique (MR) bone cuts are first made based on anatomical landmarks and soft tissue releases are subsequently conducted with implant components in-situ. Patients returned 2 weeks, 6 weeks, 12 weeks, 24 weeks, and 52 weeks following surgery for radiographic evaluation. Kinematics were assessed 52 weeks post-operatively. Results. No significant difference was observed between groups in maximum total point motion (MTPM) at any time point during the first post-operative year. MTPM of both the tibial and femoral component did not significantly change between the six month and one year follow up visits for both the GB (6 mths=0.67 ±0.34mm, 1 yr=0.65 ±0.52, p=0.71) and MR (6 mths= 0.79 ±0.53mm, 1 yr= 0.82 ±0.43mm, p=0.56) cohorts. MTPM for both components over the follow up period is displayed in Figure 1. No significant difference was observed in contact location or pattern on the medial condyle during deep flexion (Figure 2A). A significant difference (p=0.01) was observed, however, between surgical techniques in the lateral contact location at full extension (Figure 2B). No significant difference was observed in the magnitude of AP excursion for both the medial and lateral condyles within and between groups. Conclusion. Surgical technique did not impact the MTPM of an uncemented TKA design during the first post-operative year. By the six month post-operative period tibial and femoral MTPM plateaus indicating that osseointegration between the host bone and implanted components has occurred. Kinematic evaluation indicates contact locations anterior to the midline of the sagittal plane, paradoxical anterior translation, and a lateral pivot point, regardless of surgical technique


Orthopaedic Proceedings
Vol. 91-B, Issue SUPP_II | Pages 336 - 336
1 May 2009
Devane P Horne G
Full Access

Early migration of the acetabular and femoral component after total hip replacement has shown to be a good predictor of implant failure. The only current technique available for this measurement is RSA. An entirely new technique for the measurement of component migration and polyethylene wear has been developed. Required are a single CT of the patients’ pelvis and femur, and routine serial postoperative antero-posterior (AP) and lateral radiographs. A CT scan of the patients pelvis and proximal femur is performed either pre or post-operatively. This CT is used to build a solid model of the patients’ bony anatomy. CAD models of the femoral and acetabular component are obtained from the manufacturer and all four solid models are imported into custom software. Ray tracer (RT) technology is the computer generation of images of a solid model placed between a camera and a screen. It has been adapted to reproduce the radiological setup used to take clinical AP and lateral radiographs. The four solid models (pelvis, acetabular component, femoral component, femoral shaft) are each placed in the RT. Manipulation of each solid model is performed (6 degrees of freedom, x, y, z translation, and rotation about the x, y, z axis) using Artificial Intelligence, until an outline of the solid model generated by the ray tracer is identical to the outline of the AP and lateral radiograph of that patient. Change in relative positions of each solid model over time (pelvis acetabular component represents acetabular migration, acetabular component femoral stem represents polyethylene wear, and femoral stem femur represents femoral migration) are recorded. Validation to measure accuracy of the technique has been performed using computer models, and femoral and acetabular prostheses implanted into a cadaver. Despite significant variations in the position of the pelvis and leg during the obtaining of post-operative radiographs, this new technique was able to measure polyethylene wear and component migration with accuracy similar to that of RSA (0.25 mm in the AP plane). Further testing and validation is required, but this technique offers promise for the future in being able to retrospectively measure component migration and poly-ethylene wear, using a single CT scan and routine clinical postoperative radiographs


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_2 | Pages 138 - 138
1 Jan 2016
Laende E Dunbar M Richardson G Biddulph M
Full Access

Introduction. The dual mobility design concept for acetabular liners is intended to reduce the risk of dislocation and increase range of motion, but the wear pattern of this design is unclear and may have implications in implant fixation. Additionally, the solid back cups do not have the option for supplementary screw fixation, providing an additional smooth articulating surface for the liner to move against. The objective of this study was to assess cup fixation by measuring implant migration. A secondary objective was to evaluate the mobile bearing motion after rotating the hip. Methods. Thirty subjects were recruited in a consecutive series prospective study and received Anatomic Dual Mobility (Stryker Orthopedics) uncemented acetabular components with mobile bearing polyethylene liners through a direct lateral approach. Femoral stems were cemented (Exeter) or uncemented (Accolade, Stryker Orthopedics). The femur, acetabulum, and non-articulating surface of the polyethylene liner were marked with tantalum beads. Radiostereometric analysis (RSA) exams were performed post-operatively and at 6 weeks, 3, 6, months, and at 1 year. At the 1 year exam, a frog leg RSA exam was performed to assess the mobility of the cup compared to its position during a supine exam. Results. Proximal translation of the cup was 0.16 ± 0.28 mm (range −0.18 to 0.92 mm) and sagittal rotation was 0.08 ± 0.86 degrees (range −1.81 to 2.18 degrees) at 1 year. Analysis of the motion of the mobile bearing liner during the frog leg RSA exam showed total motions of between 0.10 to 5.58 mm (maximum total point motion). Discussion & Conclusions. The migration of the cup has a low group average and is on track to be in the “acceptable” range as defined by Pijls et al. [1] of less than 0.2 mm of subsidence at 2 years. The combination of low subsidence and low sagittal rotations of the cup are favorable predictors of good long-term performance [2]. The wide range of motions of the mobile bearing suggest that in some patients the liner is moving freely, while in a subset of subjects there is no motion. The implications of this in terms of the generation of wear particles and affect on implant migration will be monitored to 3 years


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_2 | Pages 137 - 137
1 Jan 2016
Laende E Richardson G Biddulph M Dunbar M
Full Access

Introduction. Debate over appropriate alignment in total knee arthroplasty has become a topical subject as technology allows planned alignments that differ from a neutral mechanical axis. These surgical techniques employ patient-specific cutting blocks derived from 3D reconstructions of pre-operative imaging, commonly MRI or CT. The patient-specific OtisMed system uses a detailed MRI scan of the knee for 3D reconstruction to estimate the kinematic axis, dictating the cutting planes in the custom-fit cutting blocks machined for each patient [1, 2]. The purpose of this study was to evaluate the correlation between post-operative limb alignment and implant migration in subjects receiving shape match derived kinematic alignment. Methods. In a randomized controlled trial comparing patient-specific cutting blocks to navigated surgery, seventeen subjects in the patient specific group had complete 1 year data. They received cruciate retaining cemented total knee replacements (Triathlon, Stryker) using patient-specific cutting blocks (OtisMed custom-fit blocks, Stryker). Intra-operatively, 6–8 tantalum markers (1 mm diameter) were inserted in the proximal tibia. Radiostereometric analysis (RSA) [3, 4] exams were performed with subjects supine on post-operative day 1 and at 6 week, 3, 6, and 12 month follow-ups with dual overhead tubes (Rad 92, Varian Medical Systems, Inc., Palo Alto, CA, USA), digital detectors (CXDI-55C, Canon Inc., Tokyo, Japan), and a uniplanar calibration box (Halifax Biomedical Inc., Mabou, NS, Canada). RSA exams were analyzed in Model-based RSA (Version 3.32, RSAcore, Leiden, The Netherlands. Post-operative limb alignment was evaluated from weight-bearing long-leg films. Results. Post-operative limb alignments ranged from 5 degrees of varus to 5 degrees of valgus. Comparing implant migration to post-operative alignment did not demonstrate a relationship between deviation from neutral mechanical alignment and increased migration (Pearson correlation coefficient = 0.25, P = 0.33) (Figure 1). Conclusions. Previous studies have suggested that alignment of greater than 3 degrees from neutral may have adverse effects on implant survivorship [5], but this early data does not suggest increased migration with non-neutral alignment. Continued evaluation with RSA to 2 years will be performed to monitor these subjects over the longer term


Orthopaedic Proceedings
Vol. 85-B, Issue SUPP_I | Pages 59 - 59
1 Jan 2003
Wilkinson JM Stockley I Hamer AJ Elson RA Eastell R
Full Access

Factors that allow the generation or ingression of wear particles at the implant-host interface after total hip arthroplasty (THA) may include early migration and periprosthetic bone loss. We have previously shown that a single 90mg dose of the bisphosphonate pamidronate prevents bone loss over 6 months after THA. In this 2 year randomised trial extension study we assessed the longer term effects of this intervention on bone loss and implant migration. Twenty-two patients received 90mg of pamidronate and 22 received placebo at randomisation 5 days after surgery. Femoral and pelvic bone mineral density (BMD) was measured by dual energy x-ray absorptiometry (DXA) and implant migration was measured using the EBRA-Digital method over a 104 week period. In the placebo group rapid periprosthetic bone loss occurred over the first 6 months. After this period a partial recovery in bone mass occurred in most regions. Patients in the pamidronate group had significantly less femoral, but not pelvic, bone loss than those give placebo (ANOVA P=0.02). Pamidronate was most effective in preventing bone loss in Gruen zones 6 and 7 (ANOVA P=0.004, and P=0.014, respectively). At week 104 the mean total stem migration was 1.77mm±0.27 and 1.62mm±0.37 for the placebo and pamidronate groups, respectively (P> 0.05). Total cup migration was 0.75mm±0.26 and 0.76mm±0.14, respectively (P> 0.05). Age at surgery accounted for 26% (linear regression r=−0.65, P=0.02) and 38% (r=−0.51, P=0.007) of the variability in stem and cup migration at week 104, with younger subjects experiencing greater migration. Stem migration at week 104 was also inversely related to the Barrack cement mantle grade (r=−0.66, r. 2. 41%, P=0.0003). Implant migration was not significantly related to changes in periprosthetic bone mass. Pamidronate therapy has a significant effect on bone mass, but not implant stability, after THA.Our findings suggest that the major determinants of early migration after THA are young patient age and poor cementing technique


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_IV | Pages 555 - 555
1 Nov 2011
White C Castellaro JL Beaulé PE Kim P
Full Access

Purpose: Although femoral neck fractures remain a concern in terms of short term failures for hip resurfacing, acetabular component position and fixation are increasingly being recognized as causes of mid term failures for hip resurfacing. The purpose of our study was to evaluate the migration pattern of a cementless acetabular component for a metal on metal hip resurfacing. Method: Between January 2006 and June 2007, 130 patients underwent metal on metal hip resurfacing; 66 hips in 60 patients were included in this analysis. Forty-eight patients were male and 12 were female, with a mean age of 50 (range, 32–66). Ninety-five percent of the surgeries were performed for osteoarthritis. All surgeries were performed by two surgeons using the Conserve Plus (Wright Medical Technology, Memphis, TN) hip resurfacing system. The acetabular component is a monoblock cobalt chrome with a porous beaded surface for osteointegration. In all cases acetabular migration was measured both vertically and horizontally, on serial radiographs using the computer-assisted Ein Bild Röntgen Analyse (EBRA) method. A minimum of three comparable radiographs is necessary for calculating the migration curves. We scored medial migration as negative horizontal movement. Results: At a mean follow up 25.3 months (range, 24–36 months), each hip had an average of 5.1 radiographs for analysis. The software excluded two cases for poor comparability ending finally with 64 cases for the analysis. Eighty-seven point five per cent of the cups showed less than 1 mm migration in the medium-lateral axis and 54.7% less than 1 mm in the vertical axis. Seventy-seven percent of the cups showed a combined migration of less than 2 mm in the observation period, without radiolucencies, leaving 23% of the acetabular components with 2 mm or greater of component migration. One of these cases required revision for aseptic loosening at 34 months. Conclusion: In our study the majority of the acetabular components were stable with some of the migration observed secondary to lack of complete initial seating due to the rigidity of the shell. Krismer et al did report on the migration of the PCA shell (also a porous beaded cobalt-chrome shell) using EBRA, with 27.5% of the shells demonstrating > 1 mm of migration. Although hip resurfacing has only mid term followup, results have been good to excellent. Caution should still be maintained since the higher frictional torque generated by the larger femoral head size as well as the nanometer size particles could negatively affect long term fixation of the acetabular component


Orthopaedic Proceedings
Vol. 87-B, Issue SUPP_III | Pages 364 - 364
1 Sep 2005
Beaulé P Le Duff M Amstutz H Biederman R Mayrhofer P
Full Access

Introduction and Aims: The purpose of this study was to validate in a clinical series a method to measure femoral component migration in surface arthroplasty based on the principles of EBRA-FCA. Method: The first 400 hybrid MMSA in 355 patients have an average of 3.5 years follow-up (range two to six years). The average age was 48 years, 73% were men and 35% had secondary osteoarthritis. All patients were evaluated prospectively at three months and then yearly. We reviewed the x-rays of 26 hips that had undergone metal-on-metal resurfacing using EBRA-FCA. Minimum follow-up was 3.5 years. Group 1was free of any clinical or radiographic signs of loosening (17 hips); group 2 had failed from femoral component aseptic loosening (nine hips). Mean age for the whole group was 50.7 years (28–67). Sixty-six percent were male and 63% were operated for osteoarthritis. We recorded migrations of 2mm or greater and the time to initiation of migration. Results: Group 2 showed significantly greater migration than group 1, respectively: 4.57 mm versus 1.62mm for centre of the head (p=0.005), 4.51mm versus 1.05mm for stem tip (p=0.001). Initial migration was significantly sooner in group 2 versus group 1: 19 months versus 29.2 months (p=0.030). In group 2, the average time to first migration detected with EBRA-FCA was significantly less than time to first clinical symptoms: 19 months versus 29.5 months (p=0.003). More importantly, the time to detection of significant migration was shorter than the time to detection of the first metaphyseal stem radiolucency: 19 months versus 24.3 months (p=0.028). Conclusion: EBRA-FCA represents a reliable tool to measure migration of femoral component, which may become essential in the assessment of the clinical performance of MMSA. It is best used in large clinical series with standardised x-ray technique and limiting the number of observers


Orthopaedic Proceedings
Vol. 85-B, Issue SUPP_I | Pages 59 - 59
1 Jan 2003
Derbyshire B Porter ML
Full Access

Introduction: Long-term, aseptic loosening is the central problem for total hip replacements (THR). 1. Several studies have suggested the possibility of predicting long-term loosening of femoral components (after about 7 years) by assessment of the short-term migration pattern (1 – 2 years) using radiostereometric analysis (RSA). 2. During the past 2 years, we have been conducting an RSA study of the Elite Plus (DePuy) femoral component migration in 25 (8M, 17F) primary THR patients (mean age 61 years). Results: The Table below shows the mean and SD of the stem centroid migrations after 12 months. The mean subsidence rate of 0.71 mm/year (15 patients) during the first month reduced to 0.16 mm/year, (22 patients) during the following two months. By the latter half of the first postoperative year, the mean rate had reduced to 0.13 mm/year. Subsidence. 0.20 ± 0.12 mm (15). Internal Rotation. 0.89 ± 0.52 deg (14). Lateral. 0.13 ± 0.09 mm (8). External Rotation. 0.16 deg (1). Medial. 0.11 ± 0.09 mm (7). Valgus Rotation. 0.09 ± 0.06 deg (5). Posterior. 0.17 ± 0.12 mm (11). Varus Rotation. 0.23 ± 0.14 deg (10). Anterior. 0.08 ± 0.08 mm (4). Flexion. 0.28 ± 0.15 deg (7). Extension. 0.15 ± 0.09 deg (8). Discussion: A study by the Oxford group (Alfaro-Adrian et al. 3. ) compared the migration of 19 Elite Plus stems with 32 Exeter (Howmedica) stems over a two year period. After 1 year, there is a remarkable similarity in the subsidence, lateral migration and internal rotation between the two groups. However, combining the posterior and anterior migrations in the present study, the mean posterior migration was 0.15 mm. This is about half of that measured by the Oxford group (0.28 mm). Furthermore, the present study shows that varus rotation is predominant – compared to valgus rotation in the Oxford group’s study


Orthopaedic Proceedings
Vol. 86-B, Issue SUPP_III | Pages 310 - 310
1 Mar 2004
Arild A Benum P Haugan K Persen L Husby OS
Full Access

Aims: The aim of this study was to measure implant migration and bone remodelling of the proximal femur two years after insertion of a customized or a standard femoral stem. Materials and methods: In a prospective, randomized study 26 hips (26 patients) have been examined postoperatively and after 3, 6, 12 and 24 months using radiostereometry (RSA) and DEXA. Thirteen hips received a customized femoral stem (Unique, SCP as) and 13 hips received a standard uncemented femoral stem (ABG¨, Stryker-Howmedica). An uncemented acetabular cup (Duraloc¨, DePuy) was used in all hips. The mean age of the patients was 55 (24–67) years. Results: The median displacement of the custom/ standard femoral stems was 0.04/0.01 mm along the - medial-lateral axis, 0.08/0.02 mm along the proximal-distal axis and 0.03/0.08 mm along the anterior-posterior axis, respectively. Statistically, there was no difference between the two groups. One custom stem subsided 5.2 mm at one year, but showed no further migration at two years. The mean decrease in bone mineral density (BMD) in all Gruen zones was 6% in the Custom-group and 7% in the ABG-group. The most pronounced bone loss was seen in Zone 7 and was 21% and 25% for the two groups, respectively. Discussion: We found no statistically signiþcant difference in short-term stem migration comparing a customized and a standard, uncemented femoral stem. Furthermore, the changes in bone mineral density were almost equal in femurs with either type of prosthesis


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_6 | Pages 47 - 47
1 Mar 2017
Teeter M Perry K Yuan X Howard J Lanting B
Full Access

Background

Surgeons generally perform total knee replacement using either a gap balancing or measured resection approach. In gap balancing, ligamentous releases are performed first to create an equal joint space before any bony resections are performed. In measured resection, bony resections are performed first to match anatomical landmarks, and soft tissue releases are subsequently performed to balance the joint space. Previous studies have found a greater rate of coronal instability and femoral component lift-off using the measured resection technique, but it is unknown how potential differences in loading translate into component stability and fixation.

Methods

Patients were randomly assigned at the time of referral to a surgeon performing either the gap balancing or measured resection technique (n = 12 knees per group). Both groups received an identical cemented, posterior-stabilized implant. At the time of surgery, marker beads were inserted in the bone around the implants to enable radiostereometeric analysis (RSA) imaging. Patients underwent supine RSA exams at 0–2 weeks, 6 weeks, 3 months, 6 months, and 12 months. Migration of the tibial and femoral components including maximum total point motion (MTPM) was calculated using model-based RSA software. Knee Society Scores were also recorded for each group.


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_1 | Pages 56 - 56
1 Feb 2020
Perelgut M Lanting B Teeter M
Full Access

Background

There is increasing impetus to use rapid recovery care pathways when treating patients undergoing total hip arthroplasty (THA). The direct anterior (DA) approach is a muscle sparing technique that is believed to support these new pathways. Implants designed for these approaches are available in both collared and collarless variations and understanding the impact each has is important for providing the best treatment to patients.

Purpose/Aim of Study

This study aims to examine the role of implant design on implant fixation and patient recovery.


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_IV | Pages 558 - 558
1 Nov 2011
Wilson DA Hubley-Kozey C Dunbar MJ Wilson JLA
Full Access

Purpose: The goal of this study was to investigate if musculoskeletal activation patterns measured with electromyography (EMG) are predictive of migration of total knee replacements (TKR) measured with radiostereometric analysis (RSA).

Method: 37 TKR patients who were part of a larger randomized controlled RSA trial were recruited to this study. Study participants had been randomized to receive the Nexgen LPS Trabecular Metal tibial monoblock component (n = 19), or the cemented NexGen Option Stemmed tibial component (n = 18) (Zimmer, Warsaw IN). Ethics approval was received from the institutional review board. In the week prior to their surgery, the patients went to the dynamics of human motion laboratory and underwent EMG data collection. Surface electrodes were placed over the vastus lateralis, vastus medialis, rectus femoris, the lateral and medial hamstrings, and the lateral and medial gastrocnemius using standardized placements (Hubley-Kozey et al., 2006). The variability in subject EMG patterns was captured with a set of discrete scores that represented weightings on objectively-extracted features of the gait waveform data using principal component analysis (PCA). Within four days of surgery and at six months post-operatively, patients had bi-planar knee x-rays taken. RSA analysis was performed with MB-RSA (MEDIS, Leiden). RSA results were reported as maximum total point motion (MTPM), and six degrees of freedom translations and rotations at six months.

Results: A correlation was found between the third principle component of the lateral gastrocnemius muscle (representing high gastrocnemius activation in late stance) and the anterior migration of the component (R2=0.247 P=0.002). A correlation was found between the vastus medialis principle component three (representing low vastus medialis activation in late stance) and the anterior migration of the component (R2= 0.338, P=0.000). A stepwise regression model was developed for anterior migration of the tibial component. To reduce the number of terms in the model only the two EMG variables that were correlated with anterior migration, implant type and BMI were entered leaving four possible terms. The stepwise regression eliminated all variables but the lateral gastrocnemius and the vastus medialis. The regression equation was Anterior-Posterior Migration = 0.01 +0.12*Vastus Medialis PC3 + 0.074*Lateral Gastrocnemius PC3 (R2=0.487, R2 Adj=0.457, P< 0.0001)

Conclusion: It has previously been shown that anterior shear on the tibial component of TKR is temporally localized to the last third of stance phase of gait. Both the gastrocnemius and vastus muscle groups have the ability to produce large anterior posterior shear on an the knee during late stance. This result shows that variables which capture the temporal activation patterns of these muscles preoperatively are related to the migration of the tibial component of TKR postoperatively. This may have implications for rehabilitation of these patients.


The Bone & Joint Journal
Vol. 99-B, Issue 10 | Pages 1290 - 1297
1 Oct 2017
Devane PA Horne JG Foley G Stanley J

Aims

This paper describes the methodology, validation and reliability of a new computer-assisted method which uses models of the patient’s bones and the components to measure their migration and polyethylene wear from radiographs after total hip arthroplasty (THA).

Materials and Methods

Models of the patient’s acetabular and femoral component obtained from the manufacturer and models of the patient’s pelvis and femur built from a single computed tomography (CT) scan, are used by a computer program to measure the migration of the components and the penetration of the femoral head from anteroposterior and lateral radiographs taken at follow-up visits. The program simulates the radiographic setup and matches the position and orientation of the models to outlines of the pelvis, the acetabular and femoral component, and femur on radiographs. Changes in position and orientation reflect the migration of the components and the penetration of the femoral head. Validation was performed using radiographs of phantoms simulating known migration and penetration, and the clinical feasibility of measuring migration was assessed in two patients.


The Journal of Bone & Joint Surgery British Volume
Vol. 79-B, Issue 2 | Pages 181 - 182
1 Mar 1997
Taylor M Tanner KE


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 214 - 214
1 Sep 2012
Beaulé P White C Lopez-Castellaro J Kim P
Full Access

Introduction

Although femoral neck fractures remain a concern in short term failures for hip resurfacing, acetabular component position and fixation are increasingly being recognized as causes of mid term failures for hip resurfacing. This study aimed to evaluate the migration pattern of a cobalt chrome, beaded acetabular component for a metal on metal hip resurfacing.

Methods

130 patients underwent metal on metal hip resurfacing: 66 hips in 60 patients had sufficient films to be included in this analysis. Forty-eight patients were male and 12 were female, with a mean age of 50 (range, 32–66). Ninety-five percent of the procedures were performed for osteoarthritis. In all cases acetabular migration was measured both vertically and horizontally, on serial radiographs using the computer-assisted Ein Bild Röntgen Analyse method. A minimum of three comparable radiographs is necessary for calculating the migration curves. We scored medial migration as negative horizontal movement.


Aims. The primary objective of this study was to compare the five-year tibial component migration and wear between highly crosslinked polyethylene (HXLPE) inserts and conventional polyethylene (PE) inserts of the uncemented Triathlon fixed insert cruciate-retaining total knee arthroplasty (TKA). Secondary objectives included clinical outcomes and patient-reported outcome measures (PROMs). Methods. A double-blinded, randomized study was conducted including 96 TKAs. Tibial component migration and insert wear were measured with radiostereometric analysis (RSA) at three, six, 12, 24, and 60 months postoperatively. PROMS were collected preoperatively and at all follow-up timepoints. Results. There was no clinically relevant difference in terms of tibial component migration, insert wear, and PROMs between the HXLPE and PE groups. The mean difference in tibial component migration (maximal total point migration (MTPM)) was 0.02 mm (95% confidence interval (CI) -0.07 to 0.11), which is below the value of 0.2 mm considered to be clinically relevant. Wear after five years for HXLPE was 0.16 mm (95% CI 0.05 to 0.27), and for PE was 0.23 mm (95% CI 0.12 to 0.35). The mean difference in wear rate was 0.01 mm/year (95% CI -0.02 to 0.05) in favour of the HXLPE group. Wear is mainly present on the medial side of the insert. Conclusion. There is no clinically relevant difference in tibial component migration and insert wear for up to five years between the HXLPE conventional PE inserts. For the implant studied, the potential advantages of a HXLPE insert remain to be proven under clinical conditions at longer-term follow-up. Cite this article: Bone Joint J 2023;105-B(5):518–525


The Bone & Joint Journal
Vol. 105-B, Issue 10 | Pages 1052 - 1059
1 Oct 2023
El-Sahoury JAN Kjærgaard K Ovesen O Hofbauer C Overgaard S Ding M

Aims. The primary outcome was investigating differences in wear, as measured by femoral head penetration, between cross-linked vitamin E-diffused polyethylene (vE-PE) and cross-linked polyethylene (XLPE) acetabular component liners and between 32 and 36 mm head sizes at the ten-year follow-up. Secondary outcomes included acetabular component migration and patient-reported outcome measures (PROMs) such as the EuroQol five-dimension questionnaire, 36-Item Short-Form Health Survey, Harris Hip Score, and University of California, Los Angeles Activity Scale (UCLA). Methods. A single-blinded, multi-arm, 2 × 2 factorial randomized controlled trial was undertaken. Patients were recruited between May 2009 and April 2011. Radiostereometric analyses (RSAs) were performed from baseline to ten years. Of the 220 eligible patients, 116 underwent randomization, and 82 remained at the ten-year follow-up. Eligible patients were randomized into one of four interventions: vE-PE acetabular liner with either 32 or 36 mm femoral head, and XLPE acetabular liner with either 32 or 36 mm femoral head. Parameters were otherwise identical except for acetabular liner material and femoral head size. Results. A total of 116 patients participated, of whom 77 were male. The median ages of the vE-PE 32 mm and 36 mm groups were 65 (interquartile range (IQR) 57 to 67) and 63 years (IQR 56 to 66), respectively, and of the XLPE 32 mm and 36 mm groups were 64 (IQR 58 to 66) and 61 years (IQR 54 to 66), respectively. Mean total head penetration was significantly lower into vE-PE acetabular liner groups than into XLPE acetabular liner groups (-0.219 mm (95% confidence interval -0.348 to -0.090); p = 0.001). There were no differences in wear according to head size, acetabular component migration, or PROMs, except for UCLA. There were no cases of aseptic loosening or failures requiring revision at long-term follow-up. Conclusion. Significantly lower wear was observed in vE-PE acetabular liners than in XLPE acetabular liners. No difference in wear was observed between different head size or PROMs except for the UCLA at ten years. Cite this article: Bone Joint J 2023;105-B(10):1052–1059


The Bone & Joint Journal
Vol. 106-B, Issue 2 | Pages 136 - 143
1 Feb 2024
van der Lelij TJN Marang-van de Mheen PJ Kaptein BL Koster LA Ljung P Nelissen RGHH Toksvig-Larsen S

Aims. The objective of this study was to compare the two-year migration and clinical outcomes of a new cementless hydroxyapatite (HA)-coated titanium acetabular shell with its previous version, which shared the same geometrical design but a different manufacturing process for applying the titanium surface. Methods. Overall, 87 patients undergoing total hip arthroplasty (THA) were randomized to either a Trident II HA or Trident HA shell, each cementless with clusterholes and HA-coating. All components were used in combination with a cemented Exeter V40 femoral stem. Implant migration was measured using radiostereometric analysis (RSA), with radiographs taken within two days of surgery (baseline), and at three, 12, and 24 months postoperatively. Proximal acetabular component migration was the primary outcome measure. Clinical scores and patient-reported outcome measures (PROMs) were collected at each follow-up. Results. Mean proximal migrations at three, 12, and 24 months were 0.08 mm (95% confidence interval (CI) 0.03 to 0.14), 0.11 mm (95% CI 0.06 to 0.16), and 0.14 mm (95% CI 0.09 to 0.20), respectively, in the Trident II HA group, versus 0.11 mm (95% CI 0.06 to 0.16), 0.12 mm (95% CI 0.07 to 0.17), and 0.14 mm (95% CI 0.09 to 0.19) in the Trident HA group (p = 0.875). No significant differences in translations or rotations between the two designs were found in any other direction. Clinical scores and PROMs were comparable between groups, except for an initially greater postoperative improvement in Hip disability and Osteoarthritis Outcome Symptoms score in the Trident HA group (p = 0.033). Conclusion. The Trident II clusterhole HA shell has comparable migration with its predecessor, the Trident hemispherical HA cluster shell, suggesting a similar risk of long-term aseptic loosening. Cite this article: Bone Joint J 2024;106-B(2):136–143


The Bone & Joint Journal
Vol. 103-B, Issue 5 | Pages 855 - 863
1 May 2021
Koster LA Meinardi JE Kaptein BL Van der Linden - Van der Zwaag E Nelissen RGHH

Aims. The objective of this study was to compare the two-year migration pattern and clinical outcomes of a total knee arthroplasty (TKA) with an asymmetrical tibial design (Persona PS) and a well-proven TKA with a symmetrical tibial design (NexGen LPS). Methods. A randomized controlled radiostereometric analysis (RSA) trial was conducted including 75 cemented posterior-stabilized TKAs. Implant migration was measured with RSA. Maximum total point motion (MTPM), translations, rotations, clinical outcomes, and patient-reported outcome measures (PROMs) were assessed at one week postoperatively and at three, six, 12, and 24 months postoperatively. Results. A linear mixed-effect model using RSA data of 31 asymmetrical and 38 symmetrical TKAs did not show a difference in mean MTPM migration pattern of the tibial or femoral components. Mean tibial component MTPM at two years postoperative of the asymmetrical TKA design was 0.93 mm and 1.00 mm for the symmetrical design. For the femoral component these values were 1.04 mm and 1.14 mm, respectively. No significant differences were observed in other migration parameters or in clinical and PROM measurements. Conclusion. The TKA design with an asymmetrical tibial component has comparable component migration with the proven TKA with a symmetrical tibial component. This suggests the risk of long-term aseptic loosening of the two designs is comparable. Cite this article: Bone Joint J 2021;103-B(5):855–863


Bone & Joint Research
Vol. 13, Issue 5 | Pages 226 - 236
9 May 2024
Jürgens-Lahnstein JH Petersen ET Rytter S Madsen F Søballe K Stilling M

Aims. Micromotion of the polyethylene (PE) inlay may contribute to backside PE wear in addition to articulate wear of total knee arthroplasty (TKA). Using radiostereometric analysis (RSA) with tantalum beads in the PE inlay, we evaluated PE micromotion and its relationship to PE wear. Methods. A total of 23 patients with a mean age of 83 years (77 to 91), were available from a RSA study on cemented TKA with Maxim tibial components (Zimmer Biomet). PE inlay migration, PE wear, tibial component migration, and the anatomical knee axis were evaluated on weightbearing stereoradiographs. PE inlay wear was measured as the deepest penetration of the femoral component into the PE inlay. Results. At mean six years’ follow-up, the PE wear rate was 0.08 mm/year (95% confidence interval 0.06 to 0.09 mm/year). PE inlay external rotation was below the precision limit and did not influence PE wear. Varus knee alignment did not influence PE wear (p = 0.874), but increased tibial component total translation (p = 0.041). Conclusion. The PE inlay was well fixed and there was no relationship between PE stability and PE wear. The PE wear rate was low and similar in the medial and lateral compartments. Varus knee alignment did not influence PE wear. Cite this article: Bone Joint Res 2024;13(5):226–236


The Bone & Joint Journal
Vol. 102-B, Issue 10 | Pages 1303 - 1310
3 Oct 2020
Kjærgaard K Ding M Jensen C Bragdon C Malchau H Andreasen CM Ovesen O Hofbauer C Overgaard S

Aims. The most frequent indication for revision surgery in total hip arthroplasty (THA) is aseptic loosening. Aseptic loosening is associated with polyethylene liner wear, and wear may be reduced by using vitamin E-doped liners. The primary objective of this study was to compare proximal femoral head penetration into the liner between a) two cross-linked polyethylene (XLPE) liners (vitamin E-doped (vE-PE)) versus standard XLPE liners, and b) two modular femoral head diameters (32 mm and 36 mm). Methods. Patients scheduled for a THA were randomized to receive a vE-PE or XLPE liner with a 32 mm or 36 mm metal head (four intervention groups in a 2 × 2 factorial design). Head penetration and acetabular component migration were measured using radiostereometric analysis at baseline, three, 12, 24, and 60 months postoperatively. The Harris Hip Score, University of California, Los Angeles (UCLA) Activity Score, EuroQol five-dimension questionnaire (EQ-5D), and 36-Item Short-Form Health Survey questionnaire (SF-36) were assessed at baseline, three, 12, 36, and 60 months. Results. Of 220 screened patients, 127 were included in this study. In all, 116 received the allocated intervention, and 94 had their results analyzed at five years. Head penetration was similar between liner materials and head sizes at five years, vE-PE versus XLPE was -0.084 mm (95% confidence interval (CI) -0.173 to 0.005; p = 0.064), and 32 mm versus 36 mm was -0.020 mm (95% CI -0.110 to 0.071; p = 0.671), respectively. No differences were found in acetabular component migration or in the patient-reported outcome measures. Conclusion. No significant difference in head penetration was found at five years between vE-PE and XLPE liners, nor between 32 mm and 36 mm heads. Cite this article: Bone Joint J 2020;102-B(10):1303–1310


The Bone & Joint Journal
Vol. 99-B, Issue 12 | Pages 1596 - 1602
1 Dec 2017
Dunbar MJ Laende EK Collopy D Richardson CG

Aims. Hydroxyapatite coatings for uncemented fixation in total knee arthroplasty can theoretically provide a long-lasting biological interface with the host bone. The objective of this study was to test this hypothesis with propriety hydroxyapatite, peri-apatite, coated tibial components using component migration measured with radiostereometric analysis over two years as an indicator of long-term fixation. Patients and Methods. A total of 29 patients at two centres received uncemented PA-coated tibial components and were followed for two years with radiostereometric analysis exams to quantify the migration of the component. Results. While there was significant variation in individual migration patterns, the overall migration of the tibial component in the study group demonstrated a pattern of initial migration followed by stabilisation after one year, with mean maximum total point motion (MTPM) of 0.02 mm (standard deviation (. sd. ) 0.20) between one and two years post-operatively. The direction of greatest motion was subsidence, which stabilised at three months post-operatively (mean translation of 0.21 mm, . sd. 0.40). Conclusion. The tibial component migration pattern of stabilisation in the second post-operative year is indicative of successful long-term fixation for this PA-coated tibial component. Cite this article: Bone Joint J 2017;99-B:1596–1602


The Bone & Joint Journal
Vol. 101-B, Issue 5 | Pages 565 - 572
1 May 2019
Teeter MG Marsh JD Howard JL Yuan X Vasarhelyi EM McCalden RW Naudie DDR

Aims. The purpose of the present study was to compare patient-specific instrumentation (PSI) and conventional surgical instrumentation (CSI) for total knee arthroplasty (TKA) in terms of early implant migration, alignment, surgical resources, patient outcomes, and costs. . Patients and Methods. The study was a prospective, randomized controlled trial of 50 patients undergoing TKA. There were 25 patients in each of the PSI and CSI groups. There were 12 male patients in the PSI group and seven male patients in the CSI group. The patients had a mean age of 69.0 years (. sd. 8.4) in the PSI group and 69.4 years (. sd. 8.4) in the CSI group. All patients received the same TKA implant. Intraoperative surgical resources and any surgical waste generated were recorded. Patients underwent radiostereometric analysis (RSA) studies to measure femoral and tibial component migration over two years. Outcome measures were recorded pre- and postoperatively. Overall costs were calculated for each group. Results. There were no differences (p > 0.05) in any measurement of migration at two years for either the tibial or femoral components. Movement between one and two years was < 0.2 mm, indicating stable fixation. There were no differences in coronal or sagittal alignment between the two groups. The PSI group took a mean 6.1 minutes longer (p = 0.04) and used a mean 3.4 less trays (p < 0.0001). Total waste generated was similar (10 kg) between the two groups. The PSI group cost a mean CAD$1787 more per case (p < 0.01). Conclusion. RSA criteria suggest that both groups will have revision rates of approximately 3% at five years. The advantages of PSI were minimal or absent for surgical resources used and waste eliminated, and for meeting target alignment, yet had significantly greater costs. Therefore, we conclude that PSI may not offer any advantage over CSI for routine primary TKA cases. Cite this article: Bone Joint J 2019;101-B:565–572


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_11 | Pages 50 - 50
1 Nov 2022
Nayak M Rambani R
Full Access

Abstract. Background. Although tantalum is a well recognised implant material used for revision arthroplasty, little is known regarding the use of the same in primary total hip arthroplasty. Methods. A literature search was performed to find all relevant clinical studies until March 2020, which then underwent a further selection criteria. The inclusion criteria was set as follows: Reporting on human patients undergoing primary total hip arthroplasty; Direct comparison between tantalum acetabular cups with conventional acetabular cups. for use in primary total hip arthroplasty; Radiological evaluation (cup migration, osteointegration); Clinical (functional scores, need for subsequent revision, patient-reported outcomes; Post-operative complications; Reporting findings in the English Language. After a thorough search a total of six studies were included in the review. The primary outcome. measures were clinical outcomes, implant migration, change in bone mineral density and rate of revision and infection. Results. Tantalum was found superior to titanium with regards to fewer radiolucencies, survivorship, osteointegration, decreased osteolysis and mechanical loosening. No significant difference in radioisometric analysis, bone mineral density or Harris Hip Score was found. Revision and infection rates were found to be significantly lower in tantalum group at 10 years from pooled data of national joint registry. Conclusion. The use of tantalum can be reserved for cases of high risk of failure or mechanical loosening, where failure of a contralateral joint occurred as it carries lower risk of failure and infection. Further studies with longer follow-up would be useful in drawing further conclusions


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_7 | Pages 132 - 132
4 Apr 2023
Callary S Abrahams J Zeng Y Clothier R Costi K Campbell D Howie D Solomon L
Full Access

First-time revision acetabular components have a 36% re-revision rate at 10 years in Australia, with subsequent revisions known to have even worse results. Acetabular component migration >1mm at two years following revision THA is a surrogate for long term loosening. This study aimed to measure the migration of porous tantalum components used at revision surgery and investigate the effect of achieving press-fit and/or three-point fixation within acetabular bone. Between May 2011 and March 2018, 55 patients (56 hips; 30 female, 25 male) underwent acetabular revision THR with a porous tantalum component, with a post-operative CT scan to assess implant to host bone contact achieved and Radiostereometric Analysis (RSA) examinations on day 2, 3 months, 1 and 2 years. A porous tantalum component was used because the defects treated (Paprosky IIa:IIb:IIc:IIIa:IIIb; 2:6:8:22:18; 13 with pelvic discontinuity) were either deemed too large or in a position preventing screw fixation of an implant with low coefficient of friction. Press-fit and three-point fixation of the implant was assessed intra-operatively and on postoperative imaging. Three-point acetabular fixation was achieved in 51 hips (92%), 34 (62%) of which were press-fit. The mean implant to host bone contact achieved was 36% (range 9-71%). The majority (52/56, 93%) of components demonstrated acceptable early stability. Four components migrated >1mm proximally at two years (1.1, 3.2, 3.6 and 16.4mm). Three of these were in hips with Paprosky IIIB defects, including 2 with pelvic discontinuity. Neither press-fit nor three-point fixation was achieved for these three components and the cup to host bone contact achieved was low (30, 32 and 59%). The majority of porous tantalum components had acceptable stability at two years following revision surgery despite treating large acetabular defects and poor bone quality. Components without press-fit or three-point fixation were associated with unacceptable amounts of early migration


Aims. Vitamin E-infused highly crosslinked polyethylene (VEPE) has been introduced into total hip arthroplasty (THA) with the aim of further improving the wear characteristics of moderately and highly crosslinked polyethylenes (ModXLPE and HXLPE). There are few studies analyzing the outcomes of vitamin E-infused components in cemented arthroplasty, though early acetabular component migration has been reported. The aim of this study was to measure five-year polyethylene wear and acetabular component stability of a cemented VEPE acetabular component compared with a ModXLPE cemented acetabular component. Methods. In a prospective randomized controlled trial (RCT), we assessed polyethylene wear and acetabular component stability (primary outcome) with radiostereometric analysis (RSA) in 68 patients with reverse hybrid THA at five years follow-up. Patients were randomized to either a VEPE or a ModXLPE cemented acetabular component. Results. Mean polyethylene wear in the proximal direction was 0.17 mm (SD 0.15) for the VEPE group and 0.20 mm (SD 0.09) for the ModXLPE group (p = 0.005) at five years. Annual proximal wear rates were 0.03 mm/year (VEPE) and 0.04 mm/year (ModXLPE). Total 3D wear was 0.21 mm (SD 0.26) and 0.23 mm (SD 0.10) for the VEPE and ModXLPE groups, respectively (p = 0.009). Total 3D cup translation was 0.72 mm (SD 0.70) (VEPE) and 0.50 mm (SD 0.44) (ModXLPE) (p = 0.409). Conclusion. At five years, there was less polyethylene wear in the VEPE group than in the ModXLPE group. Both VEPE and ModXLPE cemented components showed low annual wear rates. Component stability was similar in the two groups and remained constant up to five years. Whether these results will equate to a lower long-term revision rate is still unknown. Cite this article: Bone Joint J 2020;102-B(12):1646–1653


Bone & Joint Open
Vol. 4, Issue 5 | Pages 306 - 314
3 May 2023
Rilby K Mohaddes M Kärrholm J

Aims. Although the Fitmore Hip Stem has been on the market for almost 15 years, it is still not well documented in randomized controlled trials. This study compares the Fitmore stem with the CementLeSs (CLS) in several different clinical and radiological aspects. The hypothesis is that there will be no difference in outcome between stems. Methods. In total, 44 patients with bilateral hip osteoarthritis were recruited from the outpatient clinic at a single tertiary orthopaedic centre. The patients were operated with bilateral one-stage total hip arthroplasty. The most painful hip was randomized to either Fitmore or CLS femoral component; the second hip was operated with the femoral component not used on the first side. Patients were evaluated at three and six months and at one, two, and five years postoperatively with patient-reported outcome measures, radiostereometric analysis, dual-energy X-ray absorptiometry, and conventional radiography. A total of 39 patients attended the follow-up visit at two years (primary outcome) and 35 patients at five years. The primary outcome was which hip the patient considered to have the best function at two years. Results. At two and five years, more patients considered the hip with the CLS femoral component as superior but without a statistically significant difference. There were no differences in clinical outcome, magnitude of femoral component migration, or change of bone mineral density at five years. At three months, the Fitmore femoral component had subsided a median -0.71 mm (interquartile range (IQR) -1.67 to -0.20) and the CLS femoral component -0.70 mm (IQR -1.53 to -0.17; p = 0.742). In both groups the femoral head centre had migrated posteriorly (Fitmore -0.17 mm (IQR -0.98 to -0.04) and CLS -0.23 mm (IQR -0.87 to 0.07; p = 0.936)). After three months neither of the femoral components showed much further migration. During the first postoperative year, one Fitmore femoral component was revised due to aseptic loosening. Conclusion. Up to five years, we found no statistically significant difference in outcomes between the Fitmore and the CLS femoral components. The slightly worse outcomes, including one revised hip because of loosening, speaks against the hypothesis that the Fitmore femoral component should be advantageous compared to the CLS if more patients had been recruited to this study. Cite this article: Bone Jt Open 2023;4(5):306–314


The Bone & Joint Journal
Vol. 102-B, Issue 6 | Pages 699 - 708
1 Jun 2020
Nieuwenhuijse MJ Vehmeijer SBW Mathijsen NMC Keizer SB

Aims. Short, bone-conserving femoral components are increasingly used in total hip arthroplasty (THA). They are expected to allow tissue-conserving implantation and to render future revision surgery more straightforward but the long-term data on such components is limited. One such component is the global tissue-sparing (GTS) stem. Following the model for stepwise introduction of new orthopaedic implants, we evaluated early implant fixation and clinical outcome of this novel short-stem THA and compared it to that of a component with established good long-term clinical outcome. Methods. In total, 50 consecutive patients ≤ 70 years old with end-stage symptomatic osteo-arthritis were randomized to receive THA with the GTS stem or the conventional Taperloc stem using the anterior supine intermuscular approach by two experienced hip surgeons in two hospitals in the Netherlands. Primary outcome was implant migration. Patients were followed using routine clinical examination, patient reported outcome using Harris Hip Score (HHS), Hip Disability And Osteoarthritis Outcome Score (HOOS), EuroQol five-dimension questionnaire (EQ5D), and Roentgen Stereophotogrammetric Analysis (RSA) at three, six, 12, and 24 months. This study evaluated the two-year follow-up results. Results. In addition to the initial migration pattern of distal migration (subsidence, Y-translation) and retroversion (Y-rotation) also exhibited by the Taperloc stem, the GTS stem showed an initial migration pattern of varization (X-translation combined with Z-rotation) and posterior translation (Z-translation). However, all components stabilized aside from one Taperloc stem which became loose secondary to malposition and was later revised. Clinical outcomes and complications were not statistically significantly different with the numbers available. Conclusion. A substantially different and more extensive initial migration pattern was seen for the GTS stem compared to the Taperloc stem. Although implant stabilization was achieved, excellent long-term survival similar to that of the Taperloc stem should not be inferred. Especially in the absence of clinically proven relevant improvement, widespread usage should be postponed until long-term safety has been established. Cite this article: Bone Joint J 2020;102-B(6):699–708


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_4 | Pages 14 - 14
1 Apr 2019
Van De Kleut M Athwal G Yuan X Teeter M
Full Access

Introduction. Total shoulder arthroplasty is the fastest growing joint replacement in recent years, with projected compound annual growth rates of 10% for 2016 through 2021 – higher than those of both the hip and knee combined. Reverse total shoulder arthroplasty (RTSA) has gained particular interest as a solution for patients with irreparable massive rotator cuff tears and failed conventional shoulder replacement, for whom no satisfactory intervention previously existed. As the number of indications for RTSA continues to grow, so do implant designs, configurations, and fixation techniques. It has previously been shown that continuous implant migration within the first two years postoperatively is predictive of later loosening and failure in the hip and knee, with aseptic loosening of implant components a guaranteed cause for revision in the reverse shoulder. By identifying implants with a tendency to migrate, they can be eliminated from clinical practice prior to widespread use. The purpose of this study is to, for the first time, evaluate the pattern and magnitude of implant component migration in RTSA using the gold standard imaging technique radiostereometric analysis (RSA). Methods. Forty patients were prospectively randomized to receive either a cemented or press-fit humeral stem, and a glenosphere secured to the glenoid with either autologous bone graft or 3D printed porous titanium (Aequalis Ascend Flex, Wright Medical Group, Memphis, TN, USA) for primary reverse total shoulder arthroplasty. Following surgery, partients are imaged using RSA, a calibrated, stereo x-ray technique, at 6 weeks (baseline), 3 months, 6 months, 1 year, and 2 years. Migration of the humeral stem and glenosphere at each time point is compared to baseline. Preliminary results are presented, with 15 patients having reached the 6-month time point by presentation. Results. Implant migration of ten participants at the 3-month time point is presented. Maximum total point motion (MTPM) is a measure of translation and rotation of the point on the implant that has moved the most from baseline. Average MTPM ± SD of the humeral stem is 1.18 ± 0.65 mm and 0.98 ± 0.46 mm for press-fit (n = 6) and cemented (n = 4) stems, respectively; and 0.25 ± 0.09 mm and 0.47 ± 0.24 mm for bone graft (n = 4) and porous titanium (n = 6) glenosphere fixations, respectively, at the 3-month time point. Conclusion. There is a trend towards increased migration with the use of press-fit humeral stems and porous titanium glenosphere fixation, though no conclusions can be made from the current sample size. Further, though differences in migration magnitude may be observed at early postoperative time points, it is expected that all fixation techniques will show stability from 1 to 2 years postoperatively


The Bone & Joint Journal
Vol. 101-B, Issue 7_Supple_C | Pages 40 - 47
1 Jul 2019
Sporer S MacLean L Burger A Moric M

Aims. Our intention was to investigate if the highly porous biological fixation surfaces of a new 3D-printed total knee arthroplasty (TKA) achieved adequate fixation of the tibial and patellar components to the underlying bone. Patients and Methods. A total of 29 patients undergoing primary TKA consented to participate in this prospective cohort study. All patients received a highly porous tibial baseplate and metal-backed patella. Patient-reported outcomes measures were recorded and implant migration was assessed using radiostereometric analysis. Results. Patient function significantly improved by three months postoperatively (p < 0.001). Mean difference in maximum total point motion between 12 and 24 months was 0.021 mm (-0.265 to 0.572) for the tibial implant and 0.089 mm (-0.337 to 0.758) for the patellar implant. The rate of tibial and patellar migration was largest over the first six postoperative weeks, with no changes in mean tibia migration occurring after six months, and no changes in mean patellar migration occurring after six weeks. One patellar component showed a rapid rate of migration between 12 and 24 months. Conclusion. Biological fixation appears to occur reliably on the highly porous implant surface of the tibial baseplate and metal-backed patellar component. Rapid migration after 12 months was measured for one patellar component. Further investigation is required to assess the long-term stability of the 3D-printed components and to determine if the high-migrating components achieve fixation. Cite this article: Bone Joint J 2019;101-B(7 Supple C):40–47


Bone & Joint Research
Vol. 5, Issue 6 | Pages 206 - 214
1 Jun 2016
Malak TT Broomfield JAJ Palmer AJR Hopewell S Carr A Brown C Prieto-Alhambra D Glyn-Jones S

Objectives. High failure rates of metal-on-metal hip arthroplasty implants have highlighted the need for more careful introduction and monitoring of new implants and for the evaluation of the safety of medical devices. The National Joint Registry and other regulatory services are unable to detect failing implants at an early enough stage. We aimed to identify validated surrogate markers of long-term outcome in patients undergoing primary total hip arthroplasty (THA). Methods. We conducted a systematic review of studies evaluating surrogate markers for predicting long-term outcome in primary THA. Long-term outcome was defined as revision rate of an implant at ten years according to National Institute of Health and Care Excellence guidelines. We conducted a search of Medline and Embase (OVID) databases. Separate search strategies were devised for the Cochrane database and Google Scholar. Each search was performed to include articles from the date of their inception to June 8, 2015. Results. Our search strategy identified 1082 studies of which 115 studies were included for full article review. Following review, 17 articles were found that investigated surrogate markers of long-term outcome. These included one systematic review, one randomised control trial (RCT), one case control study and 13 case series. Validated surrogate markers included Radiostereometric Analysis (RSA) and Einzel-Bild-Röntgen-Analyse (EBRA), each measuring implant migration and wear. We identified five RSA studies (one systematic review and four case series) and four EBRA studies (one RCT and three case series). Patient Reported Outcome Measures (PROMs) at six months have been investigated but have not been validated against long-term outcomes. Conclusions. This systematic review identified two validated surrogate markers of long-term primary THA outcome: RSA and EBRA, each measuring implant migration and wear. We recommend the consideration of RSA in the pre-market testing of new implants. EBRA can be used to investigate acetabular wear but not femoral migration. Further studies are needed to validate the use of PROMs for post-market surveillance. Cite this article: T. T. Malak, J. A. J. Broomfield, A. J. R. Palmer, S. Hopewell, A. Carr, C. Brown, D. Prieto-Alhambra, S. Glyn-Jones. Surrogate markers of long-term outcome in primary total hip arthroplasty: A systematic review. Bone Joint Res 2016;5:206–214. DOI: 10.1302/2046-3758.56.2000568


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_11 | Pages 57 - 57
1 Oct 2019
Broberg JS Teeter MG Lanting B Vasarhelyi EM Howard JL Yuan X Naudie DDR
Full Access

Introduction. Surgeons performing a total knee replacement (TKR) have two techniques to assist them achieve proper bone resections and ligament tension – gap balancing (GB) and measured resection (MR). GB relies on balancing ligaments prior to bony resections, whereas bony resections are made based on anatomical landmarks in MR. Many studies have been done to compare the implant migration and kinematics between the two techniques, but the results have been varied. However, these studies have not been done on modern anatomically designed prostheses using radiostereometric analysis (RSA). Anatomical designs attempt to mimic the normal knee joint structure to return more natural kinematics to the joint, with emphasis on eliminating both paradoxical anterior motion and reduced posterior femoral rollback. Given the major design differences between anatomical and non-anatomical prostheses, it is important to investigate whether one surgical technique may have advantages another. We hypothesize that there would be no difference between GB and MR techniques in implant migration, but that GB might provide better knee kinematics. Methods. Patients were recruited to receive an anatomically designed prosthesis and randomized to groups where the GB or MR technique is used. For all patients in the study, RSA images were acquired at a 2 week baseline, as well as at 6 weeks, 3 months, and 6 months post-operatively. These images were used to collect the maximum total point motion (MTPM) of the tibial and femoral implant components relative to the bone using a model-based RSA software. A series of RSA images were also acquired at 3-months post-operatively at different knee flexion angles, ranging in 20° increments from 0° to 100°. Model-based RSA software was used to obtain the 3D positions and orientations of the femoral and tibial components, which were used to obtain the anterior-posterior (AP) contact locations for each condyle. Results. Results from 47 patients (27 GB, 20 MR) were analyzed. No significant differences were present between the two surgical techniques for tibial component MTPM at 6 weeks (mean difference=0.02 mm, p=0.61), 3 months (mean difference=0.01 mm, p=0.92), and 6 months (mean difference=0.01 mm, p=0.93) post-operatively. No significant differences were present between the two surgical techniques for femoral component MTPM at 6 weeks (mean difference=0.12 mm, p=0.08), 3 months (mean difference=0.05 mm, p=0.54), and 6 months (mean difference=0.13 mm, p=0.05) post-operatively. On the medial condyle, no significant differences in AP contact location were found at all angles between 0° and 80° of flexion (p-values from 0.28 to 0.95). There was a significant difference medially between the AP contact location of the two surgical techniques at 100° of flexion (p=0.01), indicating more posterior rollback on the medial condyle in the GB technique. On the lateral condyle, no significant differences in AP contact location were found at all angles of flexion (p-values from 0.13 to 0.62). On the medial condyle of the GB group, the AP contact location moved posteriorly 5.83 mm from 0° to 20°, anteriorly 2.60 mm from 20° to 60°, and posteriorly 7.40 mm from 60° to 100°. On the medial condyle of the MR group, the AP contact location moved posteriorly 5.36 mm from 0° to 20°, anteriorly 2.87 mm from 20° to 60°, and posteriorly 3.65 mm from 60° to 100°. On the lateral condyle of the GB group, the AP contact location moved posteriorly 6.87 mm from 0° to 20°, 0.30 mm from 20° to 60°, and 3.61 mm from 60° to 100°. On the lateral condyle of the MR group, the AP contact location moved posteriorly 6.86 mm from 0° to 20°, anteriorly 0.02 mm from 20° to 60°, and posteriorly 3.56 mm from 60° to 100°. Conclusions. The GB and MR techniques are very similar in terms of implant migration and overall kinematics when an anatomical prosthesis design is used for TKR. This study suggests that surgeon preference should be used when deciding which technique to use for implanting this anatomically designed knee replacement. For figures, tables, or references, please contact authors directly


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_1 | Pages 22 - 22
1 Feb 2020
Van De Kleut M Athwal G Yuan X Teeter M
Full Access

Introduction. Reverse total shoulder arthroplasty (RTSA) is rapidly being adopted as the standard procedure for a growing number of shoulder arthropathies. Though short-term outcomes are promising, mid- and long-term follow-ups present a number of complications – among them, humeral stem and glenosphere component loosening. Though not the primary complication, previously reported aseptic loosening required revision in 100% of cases. As the number of patients undergoing RTSA increases, especially in the younger population, it is important for surgeons to identify and utilize prostheses with stable long-term fixation. It has previously been shown in the hip and knee literature that implant migration in the first two years following surgery is predictive of later failure due to loosening in the 5=10-year postoperative window. The purpose of this study is to, for the first time, evaluate the pattern and total magnitude of implant migration in reverse shoulder arthroplasty using the gold standard imaging technique radiostereometric analysis (RSA). Methods. Forty patients were prospectively randomized to receive either a cemented or press-fit humeral stem, and a glenosphere secured to the glenoid with either autologous bone graft or 3D printed porous titanium for primary reverse total shoulder arthroplasty. Following surgery, participants are imaged using RSA, a calibrated, stereo x-ray technique. Radiographs are acquired at 6 weeks (baseline), 3 months, 6 months, 1 year, and 2 years. Migration of the humeral stem and glenosphere at each time point is compared to baseline. Migration of the prostheses is independently compared between humeral stem fixation groups and glenosphere fixation groups using a two-way repeated measures ANOVA with Tukey's test for multiple comparisons. Results. Follow-ups are ongoing and preliminary results are presented. Significant differences were observed at the 6-month and 1-year time points for superior-inferior translation (p = 0.0067, p = 0.0048), and total three-dimensional translation (p = 0.0011, p = 0.0272) between humeral stems, with press-fit humeral stems subsiding significantly more than cemented stems. Migration between the 6-month and 1-year time points was minimal for both stem fixation groups (less than 0.2 mm). No significant differences were observed along any axis at any time point for the glenosphere fixation groups. Conclusion. There is a trend towards increased subsidence with the use of press-fit stems compared to cemented stems in the first six months postoperatively, as is expected. Both implant fixation techniques demonstrate stability from six months through one year, and this trend is expected through two-year follow-up. Similarly, both glenosphere fixation techniques demonstrate immediate and stable fixation through one year


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_14 | Pages 43 - 43
1 Nov 2021
Callary S Abrahams J Zeng Y Clothier R Costi K Campbell D Howie D Solomon L
Full Access

First-time revision acetabular components have a 36% re-revision rate at 10 years in Australia, with subsequent revisions known to have even worse results. Acetabular component migration >1mm at two years following revision THA is a surrogate for long term loosening. This study aimed to measure the migration of porous tantalum components used at revision surgery and investigate the effect of achieving press-fit and/or three-point fixation within acetabular bone. Between May 2011 and March 2018, 55 patients (56 hips; 30 female, 25 male) underwent acetabular revision THR with a porous tantalum component, with a post-operative CT scan to assess implant to host bone contact achieved and Radiostereometric Analysis (RSA) examinations on day 2, 3 months, 1 and 2 years. A porous tantalum component was used because the defects treated (Paprosky IIa:IIb:IIc:IIIa:IIIb; 2:6:8:22:18; 13 with pelvic discontinuity) were either deemed too large or in a position preventing screw fixation of an implant with low coefficient of friction. Press-fit and three-point fixation of the implant was assessed intra-operatively and on postoperative imaging. Three-point acetabular fixation was achieved in 51 hips (92%), 34 (62%) of which were press-fit. The mean implant to host bone contact achieved was 36% (range 9–71%). The majority (52/56, 93%) of components demonstrated acceptable early stability. Four components migrated >1mm proximally at two years (1.1, 3.2, 3.6 and 16.4mm). Three of these were in hips with Paprosky IIIB defects, including 2 with pelvic discontinuity. Neither press-fit nor three-point fixation was achieved for these three components and the cup to host bone contact achieved was low (30, 32 and 59%). The majority of porous tantalum components had acceptable stability at two years following revision surgery despite treating large acetabular defects and poor bone quality. Components without press-fit or three-point fixation were associated with unacceptable amounts of early migration


The Bone & Joint Journal
Vol. 101-B, Issue 7_Supple_C | Pages 55 - 60
1 Jul 2019
Laende EK Richardson CG Dunbar MJ

Aims. Early implant migration measured with radiostereometric analysis (RSA) has been proposed as a useful predictor of long-term fixation of tibial components in total knee arthroplasty. Evaluation of actual long-term fixation is of interest for cemented components, as well as for cementless fixation, which may offer long-term advantages once osseointegration has occurred. The objective of this study was to compare the long-term migration with one- and two-year migration to evaluate the predictive ability of short-term migration data and to compare migration and inducible displacement between cemented and cementless (porous metal monoblock) components at least ten years postoperatively. Patients and Methods. Patients who had participated in RSA migration studies with two-year follow-up were recruited to return for a long-term follow-up, at least ten years from surgery. Two cemented tibial designs from two manufacturers and one porous metal monoblock cementless tibial design were studied. At the long-term follow-up, patients had supine RSA examinations to determine migration and loaded examinations (single leg stance) to determine inducible displacement. In total, 79 patients (54 female) returned, with mean time since surgery of 12 years (10 to 14). There were 58 cemented and 21 cementless tibial components. Results. Migration at one year and two years was significantly correlated with long-term migration (p < 0.001). Median migration at the long-term follow-up was 0.6 mm (maximum total point motion; interquartile range (IQR) 0.4 to 0.9) for the cemented group and 0.6 mm. (IQR 0.3 to 1.1) for the cementless group with no difference between groups (p = 0.99). Inducible displacement was significantly lower for the cementless components (p < 0.001). Conclusion. Long-term migration was strongly correlated with two-year migration. Although long-term migration was not different for cemented or cementless tibial components, inducible displacement at the long-term visit was significantly lower for these cementless components, suggesting superior fixation. These findings support the predictive value of short-term migration in determining long-term fixation. Cite this article: Bone Joint J 2019;101-B(7 Supple C):55–60


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_1 | Pages 7 - 7
1 Feb 2020
Hettich G Schierjott R Graichen H Jansson V Rudert M Traina F Weber P Grupp T
Full Access

Introduction. Revision total hip arthroplasty is often associated with acetabular bone defects. In most cases, assessment of such defects is still qualitative and biased by subjective interpretations. Three-dimensional imaging techniques and novel anatomical reconstructions using statistical shape models (SSM) allow a more impartial and quantitative assessment of acetabular bone defects [1]. The objectives of this study are to define five clinically relevant parameters and to assess 50 acetabular bone defects in a quantitative way. Methods. Anonymized CT-data of 50 hemi-pelvises with acetabular bone defects were included in the study. The assessment was based on solid models of the defect pelvis (i.e. pelvis with bone defect) and its anatomical reconstruction (i.e. native pelvis without bone defect) (Fig.1A). Five clinically relevant parameters were defined: (1) Bone loss, defined by subtracting defect pelvis from native pelvis. (2) Bone formation, defined by subtracting native pelvis from defect pelvis. Bone formation represents bone structures, which were not present in the native pelvis (e.g. caused by remodeling processes around a migrated implant). (3) Ovality, defined by the length to width ratio of an ellipse fitted in the defect acetabulum. A ratio of 1.0 would represent a circular acetabulum. (4) Lateral center-edge angle (LCE angle), defined by the angle between the most lateral edge of the cranial roof and the body Z-axis, and (5) implant migration, defined by the distance between center of rotation (CoR) of the existing implant and CoR of native pelvis (Fig. 1B). Results. All data are presented as single values as well as median and [25. th. , 75. th. ]- percentile (Fig.2). Bone loss was 53.6 [41.5, 76.7] ml with a minimum of 19.0 ml and maximum of 103.9 ml. Bone formation was 15.7 [10.5, 21.2] ml with a minimum of 3.5 ml and a maximum of 41.6 ml. Ovality was 1.3 [1.1, 1.4] with a minimum of 1.0 and a maximum of 2.0. LCE angle was 30.4° [21.5°, 40.1°] with a minimum of 11.6° and a maximum of 63.0°. Implant migration was 25.3 [15.1, 32.6] mm with a minimum of 5.4 mm and a maximum of 53.5 mm. Discussion. Within this study, 50 hemi-pelvises with acetabular bone defects were successfully quantified using five clinically relevant parameters. Application of this method provides impartial and quantitative data of acetabular bone defects, which could be beneficial in clinical practice for pre-operative planning or comparison of surgical outcomes. Including a larger number of cases, this method could even serve as a basis for a novel classification system for acetabular bone defects. For any figures or tables, please contact the authors directly


The Bone & Joint Journal
Vol. 101-B, Issue 7 | Pages 760 - 767
1 Jul 2019
Galea VP Rojanasopondist P Laursen M Muratoglu OK Malchau H Bragdon C

Aims. Vitamin E-diffused, highly crosslinked polyethylene (VEPE) and porous titanium-coated (PTC) shells were introduced in total hip arthroplasty (THA) to reduce the risk of aseptic loosening. The purpose of this study was: 1) to compare the wear properties of VEPE to moderately crosslinked polyethylene; 2) to assess the stability of PTC shells; and 3) to report their clinical outcomes at seven years. Patients and Methods. A total of 89 patients were enrolled into a prospective study. All patients received a PTC shell and were randomized to receive a VEPE liner (n = 44) or a moderately crosslinked polyethylene (ModXLPE) liner (n = 45). Radiostereometric analysis (RSA) was used to measure polyethylene wear and component migration. Differences in wear were assessed while adjusting for body mass index, activity level, acetabular inclination, anteversion, and head size. Plain radiographs were assessed for radiolucency and patient-reported outcome measures (PROMs) were administered at each follow-up. Results. In total, 73 patients (82%) completed the seven-year visit. Mean seven-year linear proximal penetration was -0.07 mm (. sd. 0.16) and 0.00 mm (. sd. 0.22) for the VEPE and ModXLPE cohorts, respectively (p = 0.116). PROMs (p = 0.310 to 0.807) and radiolucency incidence (p = 0.330) were not different between the polyethylene cohorts. The mean proximal shell migration rate was 0.04 mm per year (. sd. 0.09). At seven years, patients with radiolucency (34%) demonstrated greater migration (mean difference: 0.6 mm (. sd. 0.2); p < 0.001). PROMs were lower for patients with radiolucency and greater proximal migration (p = 0.009 to p = 0.045). No implants were revised for aseptic loosening. Conclusion. This is the first randomized controlled trial to report seven-year RSA results for VEPE. All wear rates were below the previously reported osteolysis threshold (0.1 mm per year). PTC shells demonstrated acceptable primary stability through seven years, as indicated by low migration and lack of aseptic loosening. However, patients with acetabular radiolucency were associated with higher shell migration and lower PROM scores. Cite this article: Bone Joint J 2019;101-B:760–767


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_1 | Pages 109 - 109
1 Jan 2017
van Hamersveld K Valstar E Toksvig-Larsen S
Full Access

Whether it is best to retain the posterior cruciate ligament in the degenerated knee, i.e. using a cruciate-retaining (CR) total knee prosthesis (TKP), or to use a more constraint posterior-stabilized (PS) TKP is of debate. There are limited studies comparing the effect of both methods on implant fixation and clinical outcome, leaving it up to the surgeon to base this decision on anything but conclusive evidence. We assessed the effect of two different philosophies in knee arthroplasty on clinical outcome and tibial component migration measured with radiostereometric analysis (RSA), by directly comparing the CR and PS version of an otherwise similarly designed cemented TKP. Sixty patients were randomized and received a Triathlon TKP (Stryker, NJ, USA) of either CR (n=30) or PS (n=30) design. RSA measurements (primary outcome) and clinical scores including the Knee Society Score and Knee injury and Osteoarthritis Outcome Score were evaluated at baseline, at three months postoperatively and at one, two, five and seven years. A linear mixed-effects model was used to analyse the repeated measurements. Both groups showed a similar implant migration pattern, with a maximum total point motion at seven years follow-up of around 0.8 mm of migration (mean difference between groups 95% CI −0.11 to 0.15mm, p=0.842). Two components (one of each group) were considered to have an increased risk of aseptic loosening. Both groups improved equally after surgery on the KSS and KOOS scores and no differences were seen during the seven years of follow-up. No differences in implant migration nor clinical results were seen seven years after cruciate-retaining compared to posterior-stabilized total knee prostheses


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_7 | Pages 11 - 11
1 May 2021
Skipsey DA Downing MR Ashcroft GP Cairns DA Kumar K
Full Access

Over the last decade stemless shoulder arthroplasty has become increasingly popular. However, stability of metaphyseal loading humeral components remains a concern. This study aimed to assess the stability of the Affinis stemless humeral component using Radiostereometric analysis (RSA). Patients underwent total shoulder arthroplasty via a standardised technique with a press-fit stemless humeral component and a cemented pegged glenoid. Tantalum beads were inserted into the humerus at the time of operation. RSA of the relaxed shoulder was completed at weeks 1, 6, 13, 26, 52 and 104 post-operatively. Stressed RSA with 12 newtons of abduction force was completed from week 13 onwards. ABRSA 5.0 software (Downing Imaging Limited, Aberdeen) was used to calculate humeral component migration and induced movement. 15 patients were recruited. Precision was: 0.041, 0.034, 0.086 and 0.101 mm for Superior, Medial, Posterior and Total Point Motion (TPM) respectively. The mean TPM over 2 years was 0.24 (0.30) mm, (Mean (Standard deviation)). The mean rate of migration per 3 month time period decreased from 0.45 (0.31) to 0.02 (0.01) mm over 2 years. Mean inducible movement TPM peaked at 26 weeks at 0.1 (0.08) mm, which reduced to 0.07 (0.06) mm by 104 weeks when only 3 patients had measurable inducible motion. There was no clear trend in direction of induced movement. There were no adverse events or revisions required. We conclude migration of the humeral component was low with little inducible movement in the majority of patients implying initial and 2 year stability of the stemless humeral component


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_21 | Pages 57 - 57
1 Dec 2016
Laende E Dunbar M Richardson G Reardon G Amirault D
Full Access

The trabecular metal Monoblock TKR is comprised of a porous tantalum base plate with the polyethylene liner embedded directly in the porous metal. An alternative design, the trabecular metal Modular TKR, allows polyethylene liner insertion into the locking base plate after base plate implantation, but removes the low modulus of elasticity that was inherent in the Monoblock design. The purpose of this study was to compare the fixation of the Monoblock and Modular trabeucular metal base plates in a randomised controlled trial. Fifty subjects (30 female) were randomly assigned to receive the uncemented trabecular metal Monoblock or uncemented trabecular metal Modular knee replacement. A standard procedure of tantalum marker insertion in the proximal tibial and polyethylene liner was followed with uniplanar radiostereometric analysis (RSA) examinations immediately post-operatively and at 6 week, 3 month, 6 month, and 12 month follow-ups. The study was approved by the Research Ethics Board and all subjects signed an Informed Consent Form. Twenty-one subjects received Monoblock components and 20 received Modular components. An intra-operative decision to use cemented implants occurred in 5 cases and 4 subjects did not proceed to surgery after enrollment. The clinical precision of implant migration measured as maximum total point motion (MTPM) was 0.13 mm (upper limit of 95% confidence interval of double exams). Implant migration at 12 months was 0.88 ± 0.64 mm (mean and standard deviation; range 0.21 – 2.84 mm) for the Monoblock group and 1.60 ± 1.51 mm (mean and standard deviation; range 0.27 – 6.23 mm) for the Modular group. Group differences in 12 month migration approached clinical significance (p = 0.052, Mann Whitney U-test). High early implant migration is associated with an increased risk for late aseptic loosening. Although not statistically significant, the mean migration for the Modular component group was nearly twice that of the Monoblock, which places it at the 1.6 mm threshold for “unacceptable” early migration (Pijls et al 2012). This finding is concerning in light of the recent recall of a similar trabecular metal modular knee replacement and adds validity to the use of RSA in the introduction of new or modified implant designs. Reference: Pijls, B.G., et al., Early migration of tibial components is associated with late revision: a systematic review and meta-analysis of 21,000 knee arthroplasties. Acta Orthop, 2012. 83(6): p. 614–24


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_12 | Pages 27 - 27
1 Oct 2018
Sporer S MacLean L Burger A
Full Access

Introduction. Uncemented highly porous titanium implants have been shown to promote osseointegration, and may result in a durable construct for total knee arthroplasty (TKA). Given the mixed results of uncemented TKA, it is important to evaluate the early stability for this product. The objective of the following study was to use radiostereometric analysis (RSA) to assess early fixation of a highly porous tibial baseplate and metal backed patella. Methods. Twenty-seven patients (mean age 64 years, 30% female) undergoing primary TKA consented to participate in this prospective cohort study. All patients received a highly porous tibial baseplate, a metal backed patella and tantalum RSA bone markers. Implant migration was assessed using model-based RSA at 1.5, 3, 6, 12 and 24 months post-operative. Patient reported outcome measures were captured using the same follow-up schedule, and compared to pre-operative measures. Results. There were no adverse events affecting implant fixation, and no revisions. Patient function significantly improved by 3 months post-operation (p < 0.001). The highest rate of tibia and patellar component migration occurred over the first six post-operative weeks, with minimal migration thereafter. Mean maximum total point motion (MTPM) at 24 months was 0.72 (SD 0.34) mm for the tibia, and 0.44 (SD 0.25) mm for the patella. Three tibia baseplates migrated more than 1 standard deviation greater than the mean at 24 months, and also had continuous migration (> 0.2mm of MTPM) in the second post-operative year. One patellar component showed a rapid rate of migration between 6 and 24 months, whereas all other patellar components appeared to stabilize. Conclusions. Osseointegration appears to occur on the highly porous implant surface of the tibia baseplate and metal backed patella, as evidenced by implant stability. Further follow-up is required to determine if clinical loosening will manifest in the continuously migrating implants


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_I | Pages 225 - 225
1 Mar 2010
Devane P Horne G
Full Access

Measurement of polyethylene (PE) wear in total hip joint replacement (THJR) is performed by measuring change in the position of the femoral head on post-operative radiographs. Early methods used manual measurement with calipers and concentric circles, while more recent techniques involve the use of computer assisted technology. RSA, while mainly used for measuring component migration, can also be used for measurement of PE wear. The aim of this paper is to describe two new methods for measuring PE wear;. A completely automated measurement (which eliminates user error and is 100% reproducible). A method currently under development which uses artificial intelligence to match CAD models to radiographs, enabling measurement of both PE wear and prosthesis migration. For the Automated Measurement Technique (AMT), software has been developed which locates the centre of the acetabular cup and femoral head on both the anteroposterior and lateral radiographs. No user input is required. Accuracy is ± 0.16 mm. Clinically, it has been used in a double-blinded randomized controlled trial (RCT) comparing conventional with cross-linked PE. For the Model Matching Technique (MMT), two pieces of software are combined, Ray-Tracing technology (used in the generation of animated movies), and the Genetic Algorithm (a branch of Artificial Intelligence). CAD models of an acetabular cup and femoral head are matched to post-operative films to position them in 3D space. Change in position of these models over time represents PE wear. CAD models of the patients’ pelvis and femur (built from CT scans) can be similarly used to measure femoral and acetabular component migration. The AMT was used to measure the PE wear of 116 patients enrolled in a prospective RCT comparing conventional and cross-linked PE. At a follow-up of two to four years, cross-linked PE showed statistic ally significant lower PE wear than the conventional material. A cadaver pelvis and femur has been used to analyse accuracy of the MMT for measurement of component migration. Preliminary results show an accuracy of ± 0.22mm for component migration. The accuracy of PE wear measurement appears to be significantly less than this. The development of new bearing surfaces to reduce wear in THJR requires new techniques of in-vivo wear measurement. These two new techniques should give important information on the performance of new bearings, and possibly allow measurement of clinical component migration without the need for bead implantation


Bone & Joint Research
Vol. 8, Issue 10 | Pages 443 - 450
1 Oct 2019
Treacy RBC Holland JP Daniel J Ziaee H McMinn DJW

Objectives. Modern metal-on-metal (MoM) hip resurfacing arthroplasty (HRA), while achieving good results with well-orientated, well-designed components in ideal patients, is contraindicated in women, men with head size under 50 mm, or metal hypersensitivity. These patients currently have no access to the benefits of HRA. Highly crosslinked polyethylene (XLPE) has demonstrated clinical success in total hip arthroplasty (THA) and, when used in HRA, potentially reduces metal ion-related sequelae. We report the early performance of HRA using a direct-to-bone cementless mono-bloc XLPE component coupled with a cobalt-chrome femoral head, in the patient group for whom HRA is currently contraindicated. Methods. This is a cross-sectional, observational assessment of 88 consecutive metal-on-XLPE HRAs performed in 84 patients between 2015 and 2018 in three centres (three surgeons, including the designer surgeon). Mean follow-up is 1.6 years (0.7 to 3.9). Mean age at operation was 56 years (. sd. 11; 21 to 82), and 73% of implantations were in female patients. All patients were individually counselled, and a detailed informed consent was obtained prior to operation. Primary resurfacing was carried out in 85 hips, and three cases involved revision of previous MoM HRA. Clinical, radiological, and Oxford Hip Score (OHS) assessments were studied, along with implant survival. Results. There was no loss to follow-up and no actual or impending revision or reoperation. Median OHS increased from 24 (interquartile range (IQR) 20 to 28) preoperatively to 48 (IQR 46 to 48) at the latest follow-up (48 being the best possible score). Radiographs showed one patient had a head-neck junction lucency. No other radiolucency, osteolysis, component migration, or femoral neck thinning was noted. Conclusion. The results in this small consecutive cohort suggest that metal-on-monobloc-XLPE HRA is successful in the short term and merits further investigation as a conservative alternative to the current accepted standard of stemmed THA. However, we would stress that survival data with longer-term follow-up are needed prior to widespread adoption. Cite this article: R. B. C. Treacy, J. P. Holland, J. Daniel, H. Ziaee, D. J. W. McMinn. Preliminary report of clinical experience with metal-on-highly-crosslinked-polyethylene hip resurfacing. Bone Joint Res 2019;8:443–450. DOI: 10.1302/2046-3758.810.BJR-2019-0060.R1


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_1 | Pages 11 - 11
1 Jan 2016
Al-Khateeb H Mahmud T MacDonald S McAuley JP
Full Access

Objectives. Porous metal surfaces have been a popular option for acetabular component fixation in total hip arthroplasty (THA). New THA component designs are introduced periodically with the expectation of better wear properties and survivorship. Since its approval for use in 2002 there have been few clinical outcome studies published on the Pinnacle acetabular cup system. We hypothesised that the hemispherical porous coated Pinnacle acetabular cup system with a range of cup options and bearing surfaces would give us predictably good fixation and survivorship at five years post implantation. Materials and Methods. A total of 1391 Pinnacle acetabular cups (De Puy, a Johnson & Johnson company, Warsaw IN) were implanted between the period March 2003 to August 2011 by four senior surgeons. There were a total of 29 patients requiring revision surgery. Of these revisions, 23 were excluded from the final analysis. Sixteen were for early infection requiring debridement of the hip joint and exchange of the modular liner and femoral head. Five patients sustained femoral peri-prosthetic fractures requiring further surgery with retention of the acetabular component in all cases. Of the remaining 8 revision cases, only 6 had more than two years follow-up. All patients had pre and post-operative Harris hip scores, WOMAC and SF-12 scores. All patients were assessed with serial radiographs immediately post-operatively, 3 months, 1 year, 2 years, every 2 years thereafter. Component migration and revisions (excluding infection and peri-prosthetic fractures) are reported as failures. Post-operative radiographs were evaluated for component migration. Kaplan-Meier survivorship curves were drawn to show survivorship for cup type and bearing type. Results. A total of 894 Pinnacle acetabular components implanted into 796 patients were available for inclusion in the final analysis. There were 358 males with an average age of 63.70 years and 438 females with an average age of 64.55 years. The average period for follow-up was 44.95 months with 133 patients having more than five years of follow-up. Only one cup showed signs of aseptic loosening and component migration on plain radiographs, this patient had previously sustained an acetabular fracture requiring open reduction and internal fixation ans subsequently developed osteoarthritis. The cup failed to adequately in-grow and migrated medially to an intra-pelvic position, this was revised to a Trabelcular Metal cup with bone grafting to the acetabulum. There were two cases revised for instability. Three revisions were performed for aseptic loosening of the femoral components which were revised with retention of the acetabular cups. Conclusion. Published data on the performance of various porous coated cups have demonstrated varying degrees of osteolysis, however the Pinnacle cup has shown excellent midterm results postulated to be associated with the taper lock liner mechanism of the Pinnacle cups resulting in less micromotion and, therefore, reduced hydraulic pressure pumping polyethylene wear debris behind the cup. Our study confirms excellent overall survivorship of the Pinnacle acetabular porous coated cup system at a minimum of two years followup in over 790 patients


The Bone & Joint Journal
Vol. 99-B, Issue 4 | Pages 458 - 464
1 Apr 2017
Abrahams JM Kim YS Callary SA De Ieso C Costi K Howie DW Solomon LB

Aims. This study aimed to determine the diagnostic performance of radiographic criteria to detect aseptic acetabular loosening after revision total hip arthroplasty (THA). Secondary aims were to determine the predictive values of different thresholds of migration and to determine the predictive values of radiolucency criteria. Patients and Methods. Acetabular component migration to re-revision was measured retrospectively using Ein-Bild-Rontgen-Analyse (EBRA-Cup) and manual measurements (Sutherland method) in two groups: Group A, 52 components (48 patients) found not loose at re-revision and Group B, 42 components (36 patients) found loose at re-revision between 1980 and 2015. The presence and extent of radiolucent lines was also assessed. Results. Using EBRA, both proximal translation and sagittal rotation were excellent diagnostic tests for detecting aseptic loosening. The area under the receiver operating characteristic (ROC) curves was 0.94 and 0.93, respectively. The thresholds of 2.5 mm proximal translation or 2° sagittal rotation (EBRA) in combination with radiolucency criteria had a sensitivity of 93% and specificity of 88% to detect aseptic loosening. The sensitivity, specificity, positive predictive value and negative predictive value (NPV) of radiolucency criteria were 41%, 100%, 100% and 68% respectively. Manual measurements of both proximal translation and sagittal rotation were very good diagnostic tests. The area under the ROC curve was 0.86 and 0.92 respectively. However, manual measurements had a decreased specificity compared with EBRA. Radiolucency criteria had a poor sensitivity and NPV of 41% and 68% respectively. Conclusion. This study shows that EBRA and manual migration measurements can be used as accurate diagnostic tools to detect aseptic loosening of cementless acetabular components used at revision THA. Radiolucency criteria should not be used in isolation to exclude loosening of cementless acetabular components used at revision THA given their poor sensitivity and NPV. Cite this article: Bone Joint J 2017;99-B:458–64


The Bone & Joint Journal
Vol. 98-B, Issue 10 | Pages 1333 - 1341
1 Oct 2016
van der Voort P Valstar ER Kaptein BL Fiocco M van der Heide HJL Nelissen RGHH

Aims. The widely used and well-proven Palacos R (a.k.a. Refobacin Palacos R) bone cement is no longer commercially available and was superseded by Refobacin bone cement R and Palacos R + G in 2005. However, the performance of these newly introduced bone cements have not been tested in a phased evidence-based manner, including roentgen stereophotogrammetric analysis (RSA). Patients and Methods. In this blinded, randomised, clinical RSA study, the migration of the Stanmore femoral component was compared between Refobacin bone cement R and Palacos R + G in 62 consecutive total hip arthroplasties. The primary outcome measure was femoral component migration measured using RSA and secondary outcomes were Harris hip score (HHS), Hip disability and Osteoarthritis Outcome Score (HOOS), EuroQol 5D (EQ-5D) and Short Form 36 (SF-36). Results. Femoral component migration was comparable between Refobacin bone cement R and Palacos R + G during the two-year follow-up period with an estimated mean difference of 0.06 mm of subsidence (p = 0.56) and 0.08° of retroversion (p = 0.82). Five hips (three Refobacin bone cement R and two Palacos R + G) showed non-stabilising, continuous migration; the femoral cement mantle in these hips, was mean 0.7 mm thicker (p = 0.02) and there were more radiolucencies at the bone-cement interface (p = 0.004) in comparison to hips showing stabilising migration. Post-operative HHS was comparable throughout the follow-up period (p = 0.62). HOOS, EQ5D, and SF-36 scores were also comparable (p-values >  0.05) at the two-year follow-up point. Conclusion. Refobacin bone cement R and Palacos R + G show comparable component migration and clinical outcome during the first two post-operative years. Hips showing continuous migration are at risk for early failure. However, this seems to be unrelated to cement type, but rather to cementing technique. Cite this article: Bone Joint J 2016;98-B:1333–41


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_8 | Pages 43 - 43
1 Aug 2020
Laende E Dunbar MJ Richardson G
Full Access

The dual mobility design concept for acetabular components is intended to reduce the risk of dislocation and increase range of motion, but the wear pattern of this design is unclear and may have implications in implant fixation. Additionally, the solid back cups do not have the option for supplementary screw fixation, providing an additional smooth articulating surface for the liner to move against. The objective of this study was to assess cup fixation by measuring implant migration as well as proximal femoral head penetration to evaluate wear performance. Thirty subjects were recruited in a consecutive series prospective study and received dual mobility uncemented acetabular components with mobile bearing polyethylene liners through a direct lateral approach. Femoral stems were cemented or uncemented. All subjects had 28 mm femoral heads. The femur, acetabulum, and non-articulating surface of the mobile polyethylene liner were marked with tantalum beads. Radiostereometric analysis (RSA) exams were performed post-operatively and at 6 weeks, 3 months, 6 months, 1 year, 2 years, and 3 years. Oxford 12 Hip and Satisfaction questionnaire responses were recorded. Mobile bearing motion was assessed under fluoroscopy for a single case under loaded and unloaded conditions. Twenty-nine subjects (17 female) proceeded to surgery. Subjects were 63±11 years of age with BMIs of 28±4.7 kg/m2. Cup migration reached 0.16 ± 0.31 mm of proximal translation and 0.29±1.03 degrees of sagittal rotation at three years. A single individual had more than 3 degrees of cup rotation, occurring by 6 months and not substantially increasing after this time. Proximal translation was low for this subject. Wear of the highly cross-linked mobile bearings was 0.18 ± 0.30 mm of proximal femoral head penetration from 0 to 3 years. The mean wear rate from 1 to 3 years was 0.02 mm/year. One subject was an outlier for wear, with more than 1 mm of femoral head penetration at 1 year. However, wear did not increase after 1 year for this subject and cup migrations were below average for this individual. Similarly, the outlier for cup rotation had below average wear. Satisfaction (out of 100%) improved from 25±27% to 96±7% pre-operatively to 3 years post-operatively. Oxford 12 scores (best possible score of 48) improved from 21±7 to 43±7 over the same period. The fluoroscopic case study demonstrated visible motion of the mobile bearing during hip rotation tasks. The overall migration of the cup was low and demonstrated favorable patterns suggesting low risk of aseptic loosening. Wear rates are also within the expected range of 0 to 0.06 mm/year for highly cross-linked polyethylene. The combination of low subsidence and low sagittal rotations of the cup, and low wear of the polyethylene are favorable predictors of good long-term performance


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_9 | Pages 69 - 69
1 Oct 2020
Lawrie CM Barrack RL Nunley RM
Full Access

Introduction. Bone mineral density (BMD) is correlated with component migration and aseptic loosening after total knee arthroplasty (TKA). Older implant designs have demonstrated BMD loss up to 23% in the first 6 months after TKA, and continued to BMD decline at an average of 5% per year for as long as 2 years after TKA. The impact of component design and fixation method on BMD loss after TKA in modern implant designs has not been fully elucidated. The purpose of this study is to determine the effect of tibial tray thickness and fixation method (cemented versus cementless) on BMD loss patterns of the proximal tibia in two different modern TKA implant systems. Methods. A prospective, nonrandomized, single center study of patients undergoing primary TKA by one of two surgeons was performed with four study cohorts: cemented DePuy Attune, cementless DePuy Attune, cemented Stryker Triathlon, cementless Stryker Triathlon. Target sample size was 80, with 20 per cohort based on adhoc power analysis. Exclusion criteria included: age over 75, BMI >40, inflammatory arthritis, previous knee surgery involving the femur, tibia or tibial bone, and diagnosis of osteopenia/osteoporosis. Implant fixation type was based on surgeon intraoperative assessment of patient bone quality. Demographic data was collected preoperatively. Dual Energy X-ray Absorptiometry (DEXA) Bone Density Monitoring was performed at 6 weeks and one year postoperatively. Bone mineral density was calculated from the DEXA scans for 4 zones for the tibia relative to the keel or central peg: anterior, posterior, medial and lateral. Results were reported as BMD at 1 year postoperatively as a percentage of BMD at 6 weeks postoperatively. Results. 81 knees with complete DEXA studies at 6 weeks and 1 year postoperatively were available for analysis. The mean (SD) age at the time of surgery was 65.4 years (6.1), with 39 men and 42 women and a mean (SD) BMI of 31.2 kg/m. 2. (4.7). The patients who received cementless implants were significantly younger with a mean (SD) age of 62.1 (6.0) than those who received cemented implants with a mean age of 69.1 (3.7) (p < 0.05). There was no difference in age between implant type (p > 0.05). There was no difference in BMI or gender distribution between implant types or fixation type (p > 0.05). There was no significant difference in mean BMD loss between 6 weeks and 1 year postoperatively between the cemented and cementless Triathlon in any zone, between the cemented Triathlon and Attune in any zone, the cementless Triathlon and Attune in any zone, and the cemented and cementless attune in the lateral, anterior and posterior proximal tibia (p > 0.05). There was significantly more BMD loss seen in the medial tibia in the cemented (BMD at 1 year 88% of BMD at 6 weeks) than cementless (BMD at 1 year 103% of BMD at 6 weeks) Attune (p = 0.043). Conclusion. BMD loss at 1 year postoperatively versus 6 weeks postoperatively after TKA with two modern implant designs is not significantly affected by tibial tray thickness. BMD loss was unaffected by fixation type for the Stryker Triathlon, but was significant less for the cementless DePuy Attune than the cemented version


The Bone & Joint Journal
Vol. 97-B, Issue 1 | Pages 35 - 44
1 Jan 2015
Flivik G Kristiansson I Ryd L

We hypothesised that the removal of the subchondral bone plate (SCBP) for cemented acetabular component fixation in total hip arthroplasty (THA) offers advantages over retention by improving the cement-bone interface, without jeopardising implant stability. We have previously published two-year follow-up data of a randomised controlled trial (RCT), in which 50 patients with primary osteoarthritis were randomised to either retention or removal of the SCBP. The mean age of the retention group (n = 25, 13 males) was 70.0 years (. sd. 6.8). The mean age in the removal group (n = 25, 16 males) was 70.3 years (. sd. 7.9). Now we have followed up the patients at six (retention group, n = 21; removal group, n = 20) and ten years (retention group: n = 17, removal group: n = 18), administering clinical outcome questionnaires and radiostereometric analysis (RSA), and determining the presence of radiolucent lines (RLLs) on conventional radiographs. RSA demonstrated similar translation and rotation patterns up to six years. Between six and ten years, proximal acetabular component migration and changes of inclination were larger in the retention group, although the mean differences did not reach statistical significance. Differences in migration were driven by two patients in the SCBP retention group with extensive migration versus none in the SCBP removal group. The significant difference (p < 0.001) in the development of radiolucent lines in the retention group, previously observed at two years, increased even further during the course of follow-up (p < 0.001). While recognising SCBP removal is a more demanding technique, we conclude that, wherever possible, the SCBP should be removed to improve the cement–bone interface in order to maximise acetabular component stability and longevity. Cite this article: Bone Joint J 2015;97-B:35–44


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_11 | Pages 140 - 140
1 Jul 2014
Hjorth M Søballe K Jakobsen S Lorenzen N Mechlenburg I Stilling M
Full Access

Summary. Five year migration results of 49 large-head metal-metal (MoM) total hip arthroplasties show good implant stability and no association between implant migration and metal-ions levels, stem and cup position, or femoral bone mineral density. Introduction. The failure mechanism of metal-metal (MoM) total hip arthroplasty has been related to metal wear-debris and pseudotumor, but it is unknown whether implant fixation is affected by metal wear-debris. Patients and Methods. In July-August 2012 41 patients (10 women) at a mean age of 47 (23–63) years with a total of 49 MoM hip arthroplasties (ReCap Shell/M2a-Magnum head/Bi-Metric stem; Biomet Inc.) participated in a 5–7 year follow-up with blood tests (chrome and cobalt serum ions), questionnaires (Oxford Hip Score (OHS) and Harris Hip Score (HHS), measurement of cup and stem position and periprosthetic BMD. Further the patients had been followed with stereo-radiographs post-operative and at 1, 2 and 5 years for analysis of implant migration (Model-Based RSA 3.32). Results. 4 patients (6 hips) had elevated metal-ion levels (>7ug/l). The mean cup inclination was 45°(sd 6), the mean cup anteversion was 17°(sd7), and the mean stem anteversion was 19°(sd7). The difference between genders was statistically insignificant (p>0.09). At 5 years follow-up total translation (TT) for the stems (n=39 hips) was a mean 0.79mm (sd 0.53) and total rotation (TR) was a mean 1.99° (sd 1.53). Between 1–2 years there was no significant difference in mean TT (p=0.49)for the stems and between 2–5 years TT was mean 0.13 mm (sd 0.35) which was significant (p=0.03) but clinically very small and within the precision limits of the method. We found no significant migration along the 3 separate axes. There was no significant association between stem migration and metal ion levels >7ug/l (p=0.55), female gender (p=0.86), stem anteversion > 25° (p=0.29), T-scores < −1 (p=0.23), total OHS < 40 (p=0.19) or total HHS < 90 (p=0.68). Between 1–5 years there was no significant change in neither subsidence (p=0.14) nor in version (p=0.91) of the stems. At 5 years TT for the cups (n=36) was mean 1.21 mm (sd 0.74) and TR was mean 2.63° (sd 1.71). Between 1–2 years cup migration along the z-axis was mean 0.29 (sd 0.73) (p=0.03), which was also within precision limits of the method. There was a positive association between total OHS below 40 (n=4) and cup migration (p=0.04), but no association between cup migration and metal ion levels >7ug/l (p=0.80), female gender (p=0.74), cup inclination > 50° (p=0.93), cup anteversion > 25° (p=0.88) or HHS < 90 (p=0.93). Proximal cup migration at 5 years was mean 0.46 mm (sd 0.47), which was similar to the cup migration at 1 year (p=0.91) and 2 years (p=0.80) follow-up. No patients were revised before the final 5–7 year follow-up. Patient satisfaction was high (94%). Conclusion. All cups and stems were well-fixed between 1–5 years. We found no statistical significant correlation between implant migration and other factors that have been associated with failure of MoM hip arthroplasty such as elevated metal ion levels, component position, and female gender. Cup migration was higher in patients with a total OHS below 40. In conclusion, metal wear-debris does not seem to influence fixation of hip components in large-head MoM articulations at mid-term follow-up


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_21 | Pages 55 - 55
1 Dec 2016
Lanting B Thoren J Yuan X McCalden R McAuley J MacDonald S Vasarhelyi E Howard J Naudie D Teeter M
Full Access

Adequate fixation of implant components is an important goal for all arthroplasty procedures. Aseptic loosening is one of the leading causes of revision surgery in total knee arthroplasty. Radiostereometric analysis (RSA) is an imaging technique to measure implant migration, with established migration thresholds for well-fixed, at risk, and unacceptably migrating components. The purpose of the present study was to examine the long-term fixation of a cemented titanium fixed bearing polished tibial baseplate. Patients enrolled in a previous two-year prospective trial were recalled at ten years. All patients received a cemented, posterior-stabilised total knee replacement of the same design implanted by one of three surgeons. Of the original 35 patients, 16 were available for long-term follow-up, with one patient lost to follow-up, nine patients deceased, and a further nine patients unwilling to return to the clinic. Each patient underwent RSA imaging in a supine position using a conventional RSA protocol. Migration of the tibial component in all planes as well as maximum total point motion (MTPM) was compared between all time points (baseline, six weeks, three months, six months, one year, two years) up to the ten year follow-up visits. Outcome scores including the Knee Society Score (KSS), WOMAC, SF-12, and UCLA Activity Score were recorded. At ten years, the mean migrations of the tibial component were less than 0.1 mm and 0.1 degree in all planes relative to the post-operative RSA exam. There was no significant difference in tibial component migration between time points. However, MTPM increased significantly over time (p = 0.002), from 0.23 ± 0.18 mm at six weeks to 0.42 ± 0.20 mm at ten years. At one year, 13 patients had an acceptable MTPM level, three patients had an ‘at risk’ level, and no patient had an ‘unacceptable’ level. No patients were revised at ten years. WOMAC and KSS were significantly improved (p < 0.0001) at the latest follow-up compared to pre-operatively, but there was no difference in SF-12. The median UCLA Activity Score at latest follow-up was six (range, two to eight). The tibial baseplate demonstrated solid fixation at ten years. No patients had an unacceptable MTPM level at one year and no patients were revised at ten years, supporting the use of RSA to predict long-term loosening risk. The low level of tibial baseplate migration found in the present study correlates to the low rate of revision for this implant as reported in individual studies and in joint replacement registries


The Bone & Joint Journal
Vol. 101-B, Issue 10 | Pages 1192 - 1198
1 Oct 2019
Sköldenberg OG Rysinska AD Chammout G Salemyr M Mukka SS Bodén H Eisler T

Aims. Radiostereometric analysis (RSA) studies of vitamin E-doped, highly crosslinked polyethylene (VEPE) liners show low head penetration rates in cementless acetabular components. There is, however, currently no data on cemented VEPE acetabular components in total hip arthroplasty (THA). The aim of this study was to evaluate the safety of a new cemented VEPE component, compared with a conventional polyethylene (PE) component regarding migration, head penetration, and clinical results. Patients and Methods. We enrolled 42 patients (21 male, 21 female) with osteoarthritis and a mean age of 67 years (. sd. 5), in a double-blinded, noninferiority, randomized controlled trial. The subjects were randomized in a 1:1 ratio to receive a reverse hybrid THA with a cemented component of either argon-gas gamma-sterilized PE component (controls) or VEPE, with identical geometry. The primary endpoint was proximal implant migration of the component at two years postoperatively measured with RSA. Secondary endpoints included total migration of the component, penetration of the femoral head into the component, and patient-reported outcome measurements. Results. In total, 19 control implants and 18 implants in the VEPE group were analyzed for the primary endpoint. We found a continuous proximal migration of the component in the VEPE group that was significantly higher with a difference at two years of a mean 0.21 mm (95% confidence interval (CI) 0.05 to 0.37; p = 0.013). The total migration was also significantly higher in the VEPE group, but femoral head penetration was lower. We found no difference in clinical outcomes between the groups. Conclusion. At two years, this cemented VEPE component, although having a low head penetration and excellent clinical results, failed to meet noninferiority compared with the conventional implant by a proximal migration above the proposed safety threshold of RSA. The early proximal migration pattern of the VEPE component is a reason for continued monitoring, although a specific threshold for proximal migration and risk for later failure cannot be defined and needs further study. Cite this article: Bone Joint J 2019;101-B:1192–1198


Bone & Joint Open
Vol. 4, Issue 5 | Pages 385 - 392
24 May 2023
Turgeon TR Hedden DR Bohm ER Burnell CD

Aims

Instability is a common cause of failure after total hip arthroplasty. A novel reverse total hip has been developed, with a femoral cup and acetabular ball, creating enhanced mechanical stability. The purpose of this study was to assess the implant fixation using radiostereometric analysis (RSA), and the clinical safety and efficacy of this novel design.

Methods

Patients with end-stage osteoarthritis were enrolled in a prospective cohort at a single centre. The cohort consisted of 11 females and 11 males with mean age of 70.6 years (SD 3.5) and BMI of 31.0 kg/m2 (SD 5.7). Implant fixation was evaluated using RSA as well as Western Ontario and McMaster Universities Osteoarthritis Index, Harris Hip Score, Oxford Hip Score, Hip disability and Osteoarthritis Outcome Score, 38-item Short Form survey, and EuroQol five-dimension health questionnaire scores at two-year follow-up. At least one acetabular screw was used in all cases. RSA markers were inserted into the innominate bone and proximal femur with imaging at six weeks (baseline) and six, 12, and 24 months. Independent-samples t-tests were used to compare to published thresholds.


The Bone & Joint Journal
Vol. 105-B, Issue 10 | Pages 1045 - 1051
1 Oct 2023
Turgeon TR Righolt CH Burnell CD Gascoyne TC Hedden DR Bohm ER

Aims

The primary aim of this trial was to compare the subsidence of two similar hydroxyapatite-coated titanium femoral components from different manufacturers. Secondary aims were to compare rotational migration (anteversion/retroversion and varus/valgus tilt) and patient-reported outcome measures between both femoral components.

Methods

Patients were randomized to receive one of the two femoral components (Avenir or Corail) during their primary total hip arthroplasty between August 2018 and September 2020. Radiostereometric analysis examinations at six, 12, and 24 months were used to assess the migration of each implanted femoral component compared to a baseline assessment. Patient-reported outcome measures were also recorded for these same timepoints. Overall, 50 patients were enrolled (62% male (n = 31), with a mean age of 65.7 years (SD 7.3), and mean BMI of 30.2 kg/m2 (SD 5.2)).


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_9 | Pages 74 - 74
1 May 2017
ten Broeke R Rudolfina R Geurts J Arts J
Full Access

Background. Implant stability and is an important factor for adequate bone remodelling and both are crucial in the long-term clinical survival of total hip arthroplasty (THA). Assessment of early bone remodelling on X-rays during the first 2 years post-operatively is mandatory when stepwise introduction of a new implant is performed. Regardless of fixation type (cemented or cementless), early acetabular component migration is usually the weakest link in THA, eventually leading to loosening. Over the past years, a shift towards uncemented cup designs has occurred. Besides the established hydroxyapatite (HA) coated uncemented cups which provide ongrowth of bone, new uncemented implant designs stimulating ingrowth of bone have increased in popularity. These cups initiate ingrowth of bone into the implant by their open metallic structure with peripheral pores, to obtain a mechanical interlock with the surrounding bone, thereby stabilising the prosthesis in an early stage after implantation. This retrospective study assessed bone remodelling, osseointegration and occurrence of radiolucency around a new ingrowth philosophy acetabular implant. Methods. In a retrospectively, single centre cohort study all patients whom underwent primary THA with a Tritanium acetabular component in 2011 were included. Bone remodelling, osseointegration and occurrence of radiolucency were determined by two reviewers from X-ray images that were made at 6 weeks, 3–6-12 and 24 months post-operatively. Bone contact % was calculated based on the original Charnley and DeLee zones. According to Charnley and DeLee the outer surface of an acetabular cup is divided into 3 zones (1-2-3). For our analysis the original 3 zones were further divided into 2 producing 6 zones 1A to 3B. Each of these 6 zones were then further divided into 4 equal sections. We attributed 25 points per section in which complete bone contact without lucency was observed. If lucency was observed no points were attributed to the section. A fully osteointegrated cup in all 24 sections could therefore attain 600 points. The total of each section and zone was subsequently tallied and recalculated to produce the percentage of bone contact on a 1–100% score. Results. In 2011 131 patients; 54 male and 76 female with average age of 60.83 (SD 12.42) and 60.57 (SD 12.11) year respectively underwent primary THA at our institution and all where included in our study cohort. Majority of this cohort underwent primary THA due to osteoarthrosis and most patients were classified ASO I (18%) or ASA II (65%). At two year clinical follow-up two revision were performed. One constituted a femur and acetabulum revision due to leg length difference and a snapping hip phenomenon. Complications included 3 dislocations (all treated policlinic), 4 deep infections (all treated with Genta PMMA beads with prosthesis in situ and healed) and 1 removal of hematoma. In another patient the femoral component was revised due to a peri-prosthetic fracture. Mean bone contact % values for all Charnley and DeLee zones combined were calculated and improved from 68,18% (SD 22,36) at 6 weeks to 73,61% SD (16,26) at 3 months to 84,21% (SD 19,02) at 6 months to 86,90% (SD 16,0) at 1 year to 92,19% (SD 12,74) at two year follow-up. When analysing the bone contact % per individual zone a remarkable difference was found for zones 2A-B. In contrast to zone 1A-B and 3A-B the initial bone contact % was clearly although not significantly lower until two year follow-up. Conclusions. In this study, the bone apposition around Tritanium actebular component was retrospectively assessed until two year clinical. Our results show excellent bone apposition that continues to improve over time (at least until two year clinical follow-up) suggesting that the open trabecular Ti structure of the Tritanium has a positive effect on cup osseointegration. However, some recent reports have shown the development of reactive lines around cups with porous/trabecular metal surfaces, of which the meaning is still unclear. Our analysis indicated that especially acetabular zone 2A-B according to Charnley&DeLee needs time to establish a direct contact of the implant surface and the surrounding bone tissues. Perhaps this might be explained by reaming technique (underreaming vs line to line reaming) resulting in suboptimal seating of the cup. Therefore, careful follow-up of this new implant technology will remain necessary and continued in this study. We aim to improve cohort size and establish results at longer follow-up times. Furthermore we aim to correlate these results to RSA component migration analysis


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_2 | Pages 13 - 13
1 Jan 2016
Grosser D Benveniste S Bramwell D Krishnan J
Full Access

Background. Radiostereometric Analysis (RSA) is an accurate measure of implant migration following total joint replacement surgery. Early implant migration predicts later loosening and implant failure, with RSA a proven short-term predictor of long-term survivorship. The proximal migration of an acetabular cup has been demonstrated to be a surrogate measure of component loosening and the associated risk of revision. RSA was used to assess migration of the R3 acetabular component which utilises an enhanced porous ingrowth surface. Migration of the R3 acetabular component was also assessed when comparing the fixation technique of the femoral stems implanted. Methods. Twenty patients undergoing primary total hip arthroplasty were implanted with the R3 acetabular cup. The median age was 70 years (range, 53–87 years). During surgery tantalum markers were inserted into the acetabulum and the outer rim of the polyliner. RSA examinations were performed postoperatively at 4 to 5 days, 6, 12 and 24 months. Data was analysed for fourteen patients to determine the migration of the acetabular cup relative to the acetabulum. Of these fourteen patients, six were implanted with a cementless femoral stem and eight with a cemented femoral stem. Patients were clinically assessed using the Harris Hip Score (HHS) and Hip Disability and Osteoarthritis Outcome Score (HOOS) preoperatively and at 6, 12 and 24 months postoperatively. Results. RSA revealed no significant acetabular cup migration in all planes of translation and rotation with mean translations below 0.40 mm and mean rotations below 1 deg at 24 months. The data suggests that acetabular migration occurred primarily in the first 6 months postoperatively. We observed mean translations at 24 months of 0.36 mm (x-axis), 0.39 mm (y-axis) and 0.35 mm (z-axis). Mean rotations of 0.68 deg (x-axis), 0.99 deg (y-axis) and 0.77 deg (z-axis) were also observed at 24 months. Micromotion along the proximal-distal translation (y-axis) plane represented proximal migration of the acetabular component (Figure 1). On investigation of the femoral stems (cementless and cemented) implanted with the R3 acetabular cup, the mean proximal migration of the acetabular cup for both was 0.39 mm (CI 0.19–0.58). For cementless femoral stems a mean proximal migration of 0.45 mm (CI 0.09–0.98) and for cemented femoral stems a mean proximal migration of 0.35 mm (CI 0.24–0.45) were observed (Figure 1). A significant difference in the clinical assessment of patients when comparing pre-operative with 6, 12 and 24 months were also observed (p < 0.0001). All clinical assessments demonstrated equivalent results when comparing the post-operative follow-up time points and the R3 acetabular cup and stem combinations. Conclusions. Mean translations and rotations were higher than previously reported for acetabular components with the enhanced porous ingrowth surface. The magnitude of proximal migration 24 months postoperatively was within published ‘acceptable’ levels, albeit within the ‘at risk’ range of 0.2–1.0 mm. Comparison of the proximal migration for cementless and cemented femoral stems expressed similar outcomes, a trend also observed with the clinical assessments. These findings support further investigation and analysis of the R3 acetabular component


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_2 | Pages 136 - 136
1 Jan 2016
Laende E Richardson G Biddulph M Dunbar M
Full Access

Introduction. Surgical techniques for implant alignment in total knee arthroplasty (TKA) is a expanding field as manufacturers introduce patient-specific cutting blocks derived from 3D reconstructions of pre-operative imaging, commonly MRI or CT. The patient-specific OtisMed system uses a detailed MRI scan of the knee for 3D reconstruction to estimate the kinematic axis, dictating the cutting planes in the custom-fit cutting blocks machined for each patient. The resulting planned alignment can vary greatly from a neutral mechanical axis. The purpose of this study was to evaluate the early fixation of components in subjects randomized to receive shape match derived kinematic alignment or conventional alignment using computer navigation. A subset of subjects were evaluated with gait analysis. Methods. Fifty-one patients were randomized to receive a cruciate retaining cemented total knees (Triathlon, Stryker) using computer navigation aiming for neutral mechanical axis (standard of care) or patient-specific cutting blocks (OtisMed custom-fit blocks, Stryker). Pre-operatively, all subjects had MRI scans for cutting block construction to maintain blinding. RSA exams and health outcome questionnaires were performed post-operatively at 6 week, 3, 6, and 12 month follow-ups. A subset (9 subjects) of the patient-specific group underwent gait analysis (Optotrak TM 3020, AMTI force platforms) one-year post-TKA, capturing three dimensional (3D) knee joint angles and kinematics. Principal component analysis (PCA) was applied to the 3D gait angles and moments of the patient-specific group, a case-matched control group, and 60 previously collected asymptomatic subjects. Results. Five MRI scans for surgical planning were not useable due to motion artifacts, with 2 successfully rescanned. Ligament releases were performed in 62% of navigation cases and 32% of patient-specific cases. One patient-specific case was revised for failure of the cruciate ligament, resulting in a polyethylene liner exchange for a thicker, cruciate substituting insert. Implant migration at 1 year was 0.40±0.25 mm for the patient-specific group and 0.37±0.20 mm for the navigation group (maximum total point motions; t-test P=0.65). EQ-5D scores, Oxford Knee scores, satisfaction, pain, and range of motion were not different between groups at any follow-up to 1 year, including the polyethylene liner exchange case. The gait analysis showed that there were no statistical differences between groups. PCA captured a lower early stance phase flexion moment magnitude in the patient-specific group than the computer navigated recipients, bringing patterns further away from asymptomatic characteristics (flexion moment PC2, P=0.02). Conclusions. Implant migration was not different between groups at 1 year despite differences in implant alignment methods. Subject function and satisfaction were also not different between groups, despite significantly fewer ligament releases in the patient-specific group. However, gait analysis of a subgroup has not shown an improvement towards restoring asymptotic gait. It should be acknowledged that the production of patient-specific cutting blocks may not be possible for all patients due to the MRI scanning requirements. Continued evaluation with RSA to 2 years will be performed to monitor these subjects over the longer term


This prospective study reviews the two-year results in a series of total hip replacements using the Silent Hip ‘neck only’ prosthesis. The Silent Hip was used in 15 hips in 14 patients in combination with large bore metal heads and ASR metal cups. Results were analysed using pre-operative and two-year Harris hip scores, Oxford hip scores, and UCLA activity ratings. Radiographs were independently analysed for evidence of implant migration, loosening, and bony hypertrophy. All patients had successful outcomes at two years. The mean Harris hip score improved from 52 to 97.4, with nine patients (10 hips) scoring 100. There were 14 excellent hips and one good hip according to the Harris scoring system. The mean Oxford hip scores improved from 36.8 to 13.8, with nine patients achieving a perfect score of 12. The average UCLA activity rating improved from 5.2 to 8.1. Independent radiographic analysis demonstrated no cases of implant migration or bony hypertrophy. The only complication in the series was one DVT. The Silent Hip is a safe and effective implant in patients with adequate femoral neck bone stock


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_5 | Pages 8 - 8
1 Apr 2019
Wilson C Critchely O Callary S Campbell D
Full Access

Introduction & aims. The magnitude and pattern of acceptable migration in clinically successful cementless stems is not well understood. Radiostereometric analysis (RSA) is a well-recognised method of assessing implant migration. Previous studies have reported long term RSA results for cemented stems. The aim of this study was to assess the long-term migration characteristics of the Corail hydroxyapatite-coated cementless stem at 10 years using RSA. Method. A prospective cohort of 30 patients undergoing primary total hip arthroplasty for primary hip osteoarthritis were enrolled into a study to characterise the migration behaviour of a cementless stem. Tantalum markers were attached to the stem and placed in the bone intraoperatively, allowing for RSA measurements to be taken in vivo. Previous 5-year results have been presented. A total of 14 patients (total 15 hips, one bilateral) with mean age 82 years (range, 69–92 years) underwent repeat long-term RSA radiographs at minimum 10 years post op. The mean time to follow up was 13.9 years (range, 13.3–14.4 years). The RSA radiographs were analysed to assess for implant rotation and translation. Results. None of the 14 patients (15 hips) followed up have been revised. The migration (rotation and translation) at 6 months, 1 year, 2 years, and 6 years has been described previously. No stems had additional subsidence of more than 0.25 mm between 6 months and 6 years. The resultant mean subsidence between 2 years and 6 years was 0.03 mm, which is below the limit measurable by RSA. The long-term, 10-year results, on implant rotation and translation will be presented. Conclusions. The Corail stem exhibited variable subsidence within the first 6 months after which there is persistent stabilisation through to 6 years. 10-year results on long-term migration show no further migration. These results can be used as a gold standard for other uncemented stems


Bone & Joint Research
Vol. 11, Issue 4 | Pages 210 - 213
1 Apr 2022
Fontalis A Haddad FS


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_10 | Pages 69 - 69
1 Jun 2018
Rosenberg A
Full Access

Nutritional Status and Short-Term Outcomes Following THA; Initial Metal Ion Levels Predict Risk in MoM THA; THA Bearing Surface Trends in the US ‘07- ’14; Dislocation Following Two-Stage Revision THA; Timing of Primary THA Prior to or After Lumbar Spine Fusion; Failure Rate of Failed Constrained Liner Revision; ESR and CRP vs. Reinfection Risk in Two-Stage Revision?; Mechanical Complications of THA Based on Approach; Impaction Force and Taper-Trunnion Stability in THA; TKA in Patients Less Than 50 Years of Age; Post-operative Mechanical Axis and 20-year TKA Survival and Function; Return to Moderate to High-intensity Sports after UKA; “Running Two Rooms” and Patient Safety in TJA; Varus and Implant Migration and Contact Kinematics after TKA; Quadriceps Snips in 321 Revision TKAs; Tubercle Proximalization for Patella Infera in Revision TKA; Anterior Condylar Height and Flexion in TKA; Compression Bandage Following Primary TKA; Unsupervised Exercise vs. Traditional PT After Primary TKA and UKA


Aims

The aim of this study was to compare the migration of the femoral component, five years postoperatively, between patients with a highly cross-linked polyethylene (HXLPE) insert and those with a conventional polyethylene (PE) insert in an uncemented Triathlon fixed insert cruciate-retaining total knee arthroplasty (TKA). Secondary aims included clinical outcomes and patient-reported outcome measures (PROMs). We have previously reported the migration and outcome of the tibial components in these patients.

Methods

A double-blinded randomized controlled trial was conducted including 96 TKAs. The migration of the femoral component was measured with radiostereometry (RSA) at three and six months and one, two, and five years postoperatively. PROMs were collected preoperatively and at all periods of follow-up.


Bone & Joint 360
Vol. 12, Issue 1 | Pages 26 - 29
1 Feb 2023

The February 2023 Wrist & Hand Roundup360 looks at: ‘Self-care’ protocol for minimally displaced distal radius fractures; Treatment strategies for acute Seymour fractures in children and adolescents: including crushed open fractures; Routinely collected outcomes of proximal row carpectomy; Moving minor hand surgeries in the office-based procedure room: a population-based trend analysis; A comparison between robotic-assisted scaphoid screw fixation and a freehand technique for acute scaphoid fracture: a randomized, controlled trial; Factors associated with conversion to surgical release after a steroid injection in patients with a trigger finger; Two modern total wrist arthroplasties: a randomized comparison; Triangular fibrocartilage complex suture repair reliable even in ulnar styloid nonunion.


Bone & Joint Open
Vol. 4, Issue 7 | Pages 507 - 515
6 Jul 2023
Jørgensen PB Jakobsen SS Vainorius D Homilius M Hansen TB Stilling M

Aims

The Exeter short stem was designed for patients with Dorr type A femora and short-term results are promising. The aim of this study was to evaluate the minimum five-year stem migration pattern of Exeter short stems in comparison with Exeter standard stems.

Methods

In this case-control study, 25 patients (22 female) at mean age of 78 years (70 to 89) received cemented Exeter short stem (case group). Cases were selected based on Dorr type A femora and matched first by Dorr type A and then age to a control cohort of 21 patients (11 female) at mean age of 74 years (70 to 89) who received with cemented Exeter standard stems (control group). Preoperatively, all patients had primary hip osteoarthritis and no osteoporosis as confirmed by dual X-ray absorptiometry scanning. Patients were followed with radiostereometry for evaluation of stem migration (primary endpoint), evaluation of cement quality, and Oxford Hip Score. Measurements were taken preoperatively, and at three, 12, and 24 months and a minimum five-year follow-up.


Bone & Joint Open
Vol. 5, Issue 4 | Pages 277 - 285
8 Apr 2024
Khetan V Baxter I Hampton M Spencer A Anderson A

Aims

The mean age of patients undergoing total knee arthroplasty (TKA) has reduced with time. Younger patients have increased expectations following TKA. Aseptic loosening of the tibial component is the most common cause of failure of TKA in the UK. Interest in cementless TKA has re-emerged due to its encouraging results in the younger patient population. We review a large series of tantalum trabecular metal cementless implants in patients who are at the highest risk of revision surgery.

Methods

A total of 454 consecutive patients who underwent cementless TKA between August 2004 and December 2021 were reviewed. The mean follow-up was ten years. Plain radiographs were analyzed for radiolucent lines. Patients who underwent revision TKA were recorded, and the cause for revision was determined. Data from the National Joint Registry for England, Wales, Northern Island, the Isle of Man and the States of Guernsey (NJR) were compared with our series.


The Bone & Joint Journal
Vol. 104-B, Issue 4 | Pages 444 - 451
1 Apr 2022
Laende EK Mills Flemming J Astephen Wilson JL Cantoni E Dunbar MJ

Aims

Thresholds of acceptable early migration of the components in total knee arthroplasty (TKA) have traditionally ignored the effects of patient and implant factors that may influence migration. The aim of this study was to determine which of these factors are associated with overall longitudinal migration of well-fixed tibial components following TKA.

Methods

Radiostereometric analysis (RSA) data over a two-year period were available for 419 successful primary TKAs (267 cemented and 152 uncemented in 257 female and 162 male patients). Longitudinal analysis of data using marginal models was performed to examine the associations of patient factors (age, sex, BMI, smoking status) and implant factors (cemented or uncemented, the size of the implant) with maximum total point motion (MTPM) migration. Analyses were also performed on subgroups based on sex and fixation.


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 3 | Pages 304 - 309
1 Mar 2006
Macheras GA Papagelopoulos PJ Kateros K Kostakos AT Baltas D Karachalios TS

Between January 1998 and December 1998, 82 consecutive patients (86 hips) underwent total hip arthroplasty using a trabecular metal monoblock acetabular component. All patients had a clinical and radiological follow-up evaluation at six, 12 and 24 weeks, 12 months, and then annually thereafter. On the initial post-operative radiograph 25 hips had a gap between the outer surface of the component and the acetabular host bed which ranged from 1 to 5 mm. All patients were followed up clinically and radiologically for a mean of 7.3 years (7 to 7.5). The 25 hips with the 1 to 5 mm gaps were studied for component migration at two years using the Einzel-Bild-Roentgen-Analyse (EBRA) digital measurement method. At 24 weeks all the post-operative gaps were filled with bone and no acetabular component had migrated. The radiographic outcome of all 86 components showed no radiolucent lines and no evidence of lysis. No acetabular implant was revised. There were no dislocations or other complications. The bridging of the interface gaps (up to 5 mm) by the trabecular metal monoblock acetabular component indicates the strong osteoconductive, and possibly osteoinductive, properties of trabecular metal


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_IV | Pages 523 - 523
1 Nov 2011
Chevillotte C Pibarot V Guyen O Carret J Bejui-Hugues J
Full Access

Purpose of the study: The ceramic-on-ceramic bearing for total hip arthroplasty (THA) has been widely used in Europe for many years. There have however been few publications on its long-term outcome. The purpose of this study was to examine the outcome at nine years follow-up of 100 THA implanted without cement using a ceramic-on-ceramic bearing. Material and methods: The first 100 ceramic-on-ceramic THA implanted from November 1999 in our unit in patients aged less than 65 years were studied. The clinical assessment included the physical examination with search for complications and the Harris and Postel-Merle-d’Aubigné scores noted preoperatively and at last follow-up. The radiographic assessment was performed by two surgeons (double reading) to search for peri-prosthetic lucency, osteolysis, ossifications and implant migration. The state of the calcar was noted. The Delee-Charnley classification was used to classify the lucent lines for the acetabulum and the Gruen McNiece and Amstutz classification for the femur. Results: Among the 100 THA, 20 patients were lost to follow-up. The Harris score was 42.6 (29–55) preoperatively and 93.9 (67–100) at last follow-up. The PMA was 8 (5–11) preoperatively and 16.7 (9–18) at last follow-up. One hip was revised to change the acetabular implant at five years. There were six early dislocations [one episode (n=4), two episodes (n=2)], one late dislocation, and two episodes of subluxation without recurrence. There were no fractures of the femoral head. The radiographic analysis identified moderate bone absorption of the calcar without real osteolysis in nearly all of the patients. For a few patients, a lucent line seen early postoperatively had disappeared at last follow-up. No implant migration (cup, stem) was noted. Discussion: The clinical and radiographic outcomes are in agreement with the literature. The relatively high rate of dislocation can be explained by the diverse levels of experience of the surgical teams. The prostheses presenting dislocation did not have an unfavourable outcome, particularly radiographically. Conclusion: These clinical and radiographic results at nine years follow-up, and the current systematic use of computer assisted navigation for optimal implant positioning favour continuation of the implantation of the ceramic-on-ceramic bearing in patients aged less than 65 years


Orthopaedic Proceedings
Vol. 87-B, Issue SUPP_III | Pages 224 - 224
1 Sep 2005
Glyn-Jones S Gill H McLardy-Smith P Murray D
Full Access

Introduction: The Birmingham Hip Resurfacing (BHR) is a metal on metal prosthesis with no published independent clinical studies. It is increasingly used as an alternative to stemmed prostheses in younger patients. This study presents the 2 year migration results of the BHR femoral component using Roentgen Stereophoto-grammteric Analysis (RSA). Methods: 26 hips in 24 subjects underwent a BHR, through the postero-lateral approach using CMW3G cement. RSA marker balls were placed in the cortical bone of the femur intra-operatively. The femoral component migration was measured at intervals of 3, 6, 12 and 24 months postoperatively using the Oxford RSA system. The implants were un-modified, geometric algorithms were used to identify the femoral component. Results: The BHR femoral component showed no significant displacement from its immediate post-operative position. All components of migration showed no significant displacement in any direction, at 1 or 2 years. Conclusion: The BHR femoral component does not migrate significantly within the first two post-operative years. Its’ migration compares favourably to other designs of femoral component. The BHR is therefore likely to remain stable in the future, as the majority of implant migration occurs within the first two years


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_III | Pages 419 - 419
1 Jul 2010
Loughenbury PR MacDonald DA
Full Access

Introduction: Tibial augments are required to replace bone loss in the proximal tibia during revision total knee replacement and can be either a rectangular ‘block’ shape or an angled ‘wedge’ shape. Purpose of study: We have identified a high failure rate with the ‘wedge’ shape currently used in the Co-ordinate (DePuy) revision knee system. Methods: We report a series of revision total knee replacement procedures performed using the Co-ordinate system. All revision ‘angled’ tibial wedge implants were selected from our prospective database containing follow up records for knee replacements. Patients underwent clinical and radiological review at three months following the procedure, on the anniversary of surgery and then on a yearly basis. Those with fewer than 12 months follow-up were excluded. Results: Between December 1993 and February 2006, a total of 34 patients (19 female, 15 male) required revision knee arthroplasty with an ‘angled’ wedged tibial augment. Mean age at surgery was 59.3 years (range 46–93). Five cases were excluded due to absence of follow-up (four requiring further surgery for infection and one due to unrelated medical complications). Of the remaining 29 cases, 16 (55.2%) had no problems with the tibial implant, while 13 (44.8%) exhibited radiological changes on review. Tibial implant migration was seen in 5 cases (17.2%), all within three years of surgery. One of these has needed further revision surgery and the other four are expected to need revision in the future. Seven (24.1%) were found to have a tibial radiolucent zone, which was progressive in four cases. There was one case of stem dissociation. Conclusion: ‘Angled’ tibial wedge implants are associated with a high rate of implant migration and loosening, presumably due to the effect of shear forces. Use of these implants should be reserved for low demand patients


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_5 | Pages 93 - 93
1 Apr 2019
Anijs T Janssen D Verdonschot N
Full Access

Introduction. Aseptic loosening is the main reason for total knee arthroplasty (TKA) failure, responsible for more than 25% of the revision procedures, with most of the problems occurring with the tibial component. While early loosening can be attributed to failure of primary fixation, late implant loosening is associated with loss of fixation secondary to bone resorption due to altered physiological load transfer to the tibial bone. Several attempts have been made to investigate these changes in bone load transfer in biomechanical simulations and bone remodeling analyses, which can be useful to provide information on the effect of patient, surgery, or design-related factors. On the other hand, these factors have also been investigated in clinical studies of radiographic changes of bone density following TKA. In this study we made an overview of the knowledge obtained from these clinical studies, which can be used to inform clinical decision making and implant design choices. Methods. A literature search was performed to identify clinical follow-up studies that monitored peri-prosthetic bone changes following TKA. Within these studies, effects of the following parameters on bone density changes were investigated: post-operative time, region of interest, alignment, body weight, systemic osteoporosis, implant design and cementation. Moreover, we investigated the effect of bone density loss on implant survival. Results. A total of 19 studies was included in this overview, with a number of included patients ranging from 12 to 7,760. Most studies used DEXA (n=16), while a few studies performed analyses on calibrated digital radiographs (n=2), or computed tomography (n=1). Postoperative follow-up varied from 9 months to 10 years. Studies consistently report the largest bone density reduction within the first postoperative year. Bone loss is mainly seen in the medial region. This has been attributed to the change in alignment following surgery, during which often the pre-operative varus knee is corrected to a more physiological alignment, resulting in a load shift towards the lateral compartment. Measurements in unoperated contralateral legs were performed in 3 cases, and two studies performed standardized DEXA measurements to provide information on systemic osteoporosis. While on the short term no changes were observed, significant negative correlations have been found between severity of osteoporosis and peri-prosthetic bone density. No clear effects of bodyweight and cementation on bone loss have been identified. Although some studies do find differences between implant types, the variation in the data makes it difficult to draw general conclusions from these findings. Several studies reported no effect of bone loss on implant migration. In another study, a medial collapse was associated with a medial increase in density, suggesting that altered loading and increased stresses are responsible for both bone formation and the overload leading to collapse. Discussion. There are important lessons to be learned from these clinical studies, although generally the large spread in the DEXA data restricts strong conclusions. There is a large variation in used ROI definitions, complicating direct comparisons. Finally, most studies report density changes of well-functioning reconstructions, since only very large studies are able to gather enough failed cases


Orthopaedic Proceedings
Vol. 91-B, Issue SUPP_III | Pages 444 - 444
1 Sep 2009
Friedl G Stihsen C Radl R Rehak P Aigner R Windhager R
Full Access

Aseptic loosening is the most frequent cause of implant failure in total hip arthroplasty (THA). Additionally, failure rate was still found by some authors to be increased in patients with osteonecrosis of the femoral head (ON-FH). It is well evidenced that low initial fixation and early migration precedes and predicts long-term failure rate of both, the acetabular and femoral component in THA. This independent, double-blind, randomized, controlled study was primarily designed to evaluate whether a single infusion of 4 mg of zoledronic acid is sufficient to prevent implant migration determined by the EBRA-digital method. Fifty patients were consecutively enrolled between July 2002 and March 2005 to receive either 4 mg zoledronic acid (ZOL) or saline solution (CTR) one day after THA (Zweymüller system, cementless). Plain radiographs were performed postoperatively and all parameters were evaluated at each follow-up meeting interval at 7 weeks, 6 months, 1 year, and yearly thereafter during a median follow-up period of 2.8 years (2 years minimum). In CTR, subsidence increased up to −1.2 mm ± 0.6 SD at 2 years in CTR (P< 0.001). Less, but a near curve-linear shaped migration pattern was found for the ace-tabular component, with an averaged medialization of 0.6 mm ± 1.0 SD and a cranialization of 0.6 mm ± 0.8 SD at 2 years (P< 0.05, Friedman ANOVA) at 2 years. In ZOL, a significant reduction in bone turnover markers was accompanied by a complete prevention of cup migration in both, the transverse and vertical direction (P< 0.05, ANOVA), while there was only a trend to a decreased subsidence in stems. The study provides useful data which are promising and support the suggestions that bisphosphonates may offer significant opportunities to reduce and prevent implant migration of THA, thus increasing long-term durability of THA especially in selected high-risk patients


The Bone & Joint Journal
Vol. 106-B, Issue 5 Supple B | Pages 54 - 58
1 May 2024
Wassilew GI Zimmerer A Fischer M Nonnenmacher L O'Hara L Hube R

Aims

The use of a porous metal shell supported by two augments with the ‘footing’ technique is one solution to manage Paprosky IIIB acetabular defects in revision total hip arthroplasty. The aim of this study was to assess the medium-term implant survival and radiological and clinical outcomes of this technique.

Methods

We undertook a retrospective, two-centre series of 39 hips in 39 patients (15 male, 24 female) treated with the ‘footing’ technique for Paprosky IIIB acetabular defects between 2007 and 2020. The median age at the time of surgery was 64.4 years (interquartile range (IQR) 54.4 to 71.0). The median follow-up was 3.9 years (IQR 3.1 to 7.0).


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 3 | Pages 302 - 307
1 Mar 2012
Kadar T Furnes O Aamodt A Indrekvam K Havelin LI Haugan K Espehaug B Hallan G

In this prospective study we studied the effect of the inclination angle of the acetabular component on polyethylene wear and component migration in cemented acetabular sockets using radiostereometric analysis. A total of 120 patients received either a cemented Reflection All-Poly ultra-high-molecular-weight polyethylene or a cemented Reflection All-Poly highly cross-linked polyethylene acetabular component, combined with either cobalt–chrome or Oxinium femoral heads. Femoral head penetration and migration of the acetabular component were assessed with repeated radiostereometric analysis for two years. The inclination angle was measured on a standard post-operative anteroposterior pelvic radiograph. Linear regression analysis was used to determine the relationship between the inclination angle and femoral head penetration and migration of the acetabular component. We found no relationship between the inclination angle and penetration of the femoral head at two years’ follow-up (p = 0.9). Similarly, our data failed to reveal any statistically significant correlation between inclination angle and migration of these cemented acetabular components (p = 0.07 to p = 0.9)


The Bone & Joint Journal
Vol. 105-B, Issue 8 | Pages 912 - 919
1 Aug 2023
Cunningham LJ Walton M Bale S Trail IA

Aims

Reverse total shoulder arthroplasty (rTSA) can be used in complex cases when the glenoid requires reconstruction. In this study, a baseplate with composite bone autograft and a central trabecular titanium peg was implanted, and its migration was assessed for two years postoperatively using radiostereometric analysis (RSA).

Methods

A total of 14 patients who underwent a rTSA with an autograft consented to participate. Of these, 11 had a primary rTSA using humeral head autograft and three had a revision rTSA with autograft harvested from the iliac crest. The mean age of the patients was 66 years (39 to 81). Tantalum beads were implanted in the scapula around the glenoid. RSA imaging (stereographic radiographs) was undertaken immediately postoperatively and at three, six, 12, and 24 months. Analysis was completed using model-based RSA software. Outcomes were collected preoperatively and at two years postoperatively, including the Oxford Shoulder Score, the American Shoulder and Elbow Score, and a visual analogue score for pain. A Constant score was also obtained for the assessment of strength and range of motion.


Bone & Joint 360
Vol. 12, Issue 6 | Pages 17 - 20
1 Dec 2023

The December 2023 Hip & Pelvis Roundup360 looks at: Early hip fracture surgery is safe for patients on direct oral anticoagulants; Time to return to work by occupational class after total hip or knee arthroplasty; Is there a consensus on air travel following hip and knee arthroplasty?; Predicting whether patients will achieve minimal clinically important differences following hip or knee arthroplasty; High-dose dual-antibiotic-loaded cement for hip hemiarthroplasty in the UK (WHiTE 8): a randomized controlled trial; Vitamin E – a positive thing in your poly?; Hydroxapatite-coated femoral stems: is there a difference in fixation?


The Bone & Joint Journal
Vol. 106-B, Issue 4 | Pages 352 - 358
1 Apr 2024
Wilson JM Trousdale RT Bedard NA Lewallen DG Berry DJ Abdel MP

Aims

Dislocation remains a leading cause of failure following revision total hip arthroplasty (THA). While dual-mobility (DM) bearings have been shown to mitigate this risk, options are limited when retaining or implanting an uncemented shell without modular DM options. In these circumstances, a monoblock DM cup, designed for cementing, can be cemented into an uncemented acetabular shell. The goal of this study was to describe the implant survival, complications, and radiological outcomes of this construct.

Methods

We identified 64 patients (65 hips) who had a single-design cemented DM cup cemented into an uncemented acetabular shell during revision THA between 2018 and 2020 at our institution. Cups were cemented into either uncemented cups designed for liner cementing (n = 48; 74%) or retained (n = 17; 26%) acetabular components. Median outer head diameter was 42 mm. Mean age was 69 years (SD 11), mean BMI was 32 kg/m2 (SD 8), and 52% (n = 34) were female. Survival was assessed using Kaplan-Meier methods. Mean follow-up was two years (SD 0.97).


Bone & Joint Open
Vol. 3, Issue 11 | Pages 859 - 866
4 Nov 2022
Diesel CV Guimarães MR Menegotto SM Pereira AH Pereira AA Bertolucci LH Freitas EC Galia CR

Aims

Our objective was describing an algorithm to identify and prevent vascular injury in patients with intrapelvic components.

Methods

Patients were defined as at risk to vascular injuries when components or cement migrated 5 mm or more beyond the ilioischial line in any of the pelvic incidences (anteroposterior and Judet view). In those patients, a serial investigation was initiated by a CT angiography, followed by a vascular surgeon evaluation. The investigation proceeded if necessary. The main goal was to assure a safe tissue plane between the hardware and the vessels.


Purpose. To report clinical results and demonstrate any posterior femoral translation (PFT) in medial rotation total knee arthroplasty (TKA) of posterior cruciate ligament (PCL) retaining type. Materials and Methods. A prospective study was performed upon thirty consecutive subjects who were operated on with medial rotation TKA of PCL retaining type (Advance® Medial Pivot prosthesis with ‘Double High’ insert; Wright Medical Technology, Arlington, TN, USA) (Fig. 1). between March 2009 and March 2010 and had been followed up for a least 2 years. Inclusion criteria were age between 60 and 75 years and primary degenerative joint disease of knee graded as Kellgren Lawrence grade III or higher. Exclusion criteria were age under 60 years, any inflammatory joint disease including rheumatoid arthritis, early stage of primary degenerative joint disease of knee or any history of previous osteotomy around knee. Clinically, the knee society knee score and function score were used to evaluate pain and function. At last follow-up, all subjects performed full extension, thirty degree flexion and full active flexion sequentially under fluoroscopic surveillance. In each of these lateral radiographs, anteroposterior(AP) condylar position was pinpointed and the magnitude of PFT was determined by degree of transition of AP condylar position from full extension to full active flexion radiograph (Fig. 2 A–B). Statistical methods used were paired t-test, Pearson correlation, Steadman rank correlation and regression analysis. Component migration and radiolucent line were also observed. Results. At last follow-up, the mean knee society knee score and the mean function score improved significantly compared to preoperative scores (from 61.5 to 90.4 and from 57.8 to 84.7 respectively). The mean maximum flexion of knee increased postoperatively compared to preoperative one without any significant difference (105.5Ëš±11.2Ëšvs 109.3Ëš±9.8Ëš, p=0.051, β=0.387). Neverthless, regression analysis showed a good linear association (r = 0.53, p=0.0027) between the pre- and post-operative maximum flexions of knee. The AP condylar positions were consistently posterior to midline throughout the entire range of flexion. The mean maximum PFT was 10.5 mm (± 4.3 mm) and the magnitude of maximum PFT was greater in higher flexion cases (r = 0.57, p = 0.0009) (Fig. 3). There were no cases having either component migration or radiolucent line except for one case showing instability related to trauma. Conclusions. In medial rotation total knee arthroplasty of PCL retaining type, clinical outcomes were satisfactory and the maximum obtainable flexions tended to be in narrower ranges than those of preoperative ones and smaller than those of other TKA prostheses. Nonetheless, reliable posterior femoral translations were observed during progressive flexions of knees, which was considered to be one of important kinematic factors in increasing the level of knee flexion of medial-rotation TKA in longer follow-ups by providing greater posterior clearance and reduced femoro-tibial impingement


The Bone & Joint Journal
Vol. 106-B, Issue 5 Supple B | Pages 82 - 88
1 May 2024
Villa JM Rajschmir K Hosseinzadeh S Manrique-Succar J Grieco P Higuera-Rueda CA Riesgo AM

Aims

Large bone defects resulting from osteolysis, fractures, osteomyelitis, or metastases pose significant challenges in acetabular reconstruction for total hip arthroplasty. This study aimed to evaluate the survival and radiological outcomes of an acetabular reconstruction technique in patients at high risk of reconstruction failure (i.e. periprosthetic joint infection (PJI), poor bone stock, immunosuppressed patients), referred to as Hip Reconstruction In Situ with Screws and Cement (HiRISC). This involves a polyethylene liner embedded in cement-filled bone defects reinforced with screws and/or plates for enhanced fixation.

Methods

A retrospective chart review of 59 consecutive acetabular reconstructions was performed by four surgeons in a single institution from 18 October 2018 to 5 January 2023. Cases were classified based on the Paprosky classification, excluding type 1 cases (n = 26) and including types 2 or 3 for analysis (n = 33). Radiological loosening was evaluated by an orthopaedic surgeon who was not the operating surgeon, by comparing the immediate postoperative radiographs with the ones at latest follow-up. Mean follow-up was 557 days (SD 441; 31 to 1,707).


Orthopaedic Proceedings
Vol. 86-B, Issue SUPP_I | Pages 19 - 19
1 Jan 2004
Glyn-Jones S Gill H McLardy-Smith P Murray D
Full Access

The Birmingham reSurfacing Arthroplasty (BSA) is a metal on metal prosthesis with no published independent clinical studies. Despite this, it is increasing in popularity, especially as an alternative to stemmed prostheses in younger patients. This study presents the 1year migration results of the BSA femoral component using Roentgen Stereophotogrammteric Analysis (RSA). Twenty six subjects underwent a BSA, through the postero-lateral approach using CMW3G cement, with RSA marker balls placed intra-operatively. The femoral component migration was measured at intervals of 3, 6 and 12 months using the Oxford RSA system. Geometric algorhythms were used to identify the femoral component. The data was examined for distribution prior to analysis. All statistical analysis was performed using the t-test. The data was normally distributed. The 1 year migration results of the BSA femoral component are displayed below. All cemented implants migrate in vivo. The majority of cemented stemmed implant migration occurs within the first post-operative year. High rates of migration within the first post-operative year correlate with premature component failure in some instances. The BSA is a fundamentally different design to most cemented prostheses, despite this we know that very large migrations, those in excess of 2mm/year in any direction are generally regarded as poor indicators of long term outcome. These results suggest that the BSA femoral component is an inherently stable device as it does not migrate significantly within the first post-operative year. Only long-term independent clinical studies and continued RSA follow-up will enable a comprehensive evaluation of the device


Bone & Joint Open
Vol. 4, Issue 2 | Pages 53 - 61
1 Feb 2023
Faraj S de Windt TS van Hooff ML van Hellemondt GG Spruit M

Aims

The aim of this study was to assess the clinical and radiological results of patients who were revised using a custom-made triflange acetabular component (CTAC) for component loosening and pelvic discontinuity (PD) after previous total hip arthroplasty (THA).

Methods

Data were extracted from a single centre prospective database of patients with PD who were treated with a CTAC. Patients were included if they had a follow-up of two years. The Hip Disability and Osteoarthritis Outcome Score (HOOS), modified Oxford Hip Score (mOHS), EurQol EuroQoL five-dimension three-level (EQ-5D-3L) utility, and Numeric Rating Scale (NRS), including visual analogue score (VAS) for pain, were gathered at baseline, and at one- and two-year follow-up. Reasons for revision, and radiological and clinical complications were registered. Trends over time are described and tested for significance and clinical relevance.


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_12 | Pages 26 - 26
1 Oct 2018
Dunbar MJ Laende E Richardson CG
Full Access

Introduction. Cementless fixation in total knee arthroplasty has been proposed to offer advantages long-term once osteointegration has occurred as there is no substrate between the implant and the bone to fail. Radiostereometric analysis (RSA) is a useful tool to study fixation, but typically focused on early migration in the first two post-operative years. Few studies have looked at 10-year RSA migration in cementless fixation and those that have contain small numbers of subjects. The objective of this study was to compare implant migration and inducible displacement between cemented and cementless TKA at 10 years and to compare the 10-year migration to the 2-year data in an effort to validate the predictive modelling of RSA. Methods. Subjects who had previously participated in RSA migration studies with 2-year follow-up were recruited to return for a long-term follow-up exam, at least 10 years from their surgery. The implants under study included two cemented designs from two manufacturers and one porous metal monoblock cementless design. At the 10-year visit, subjects had supine RSA exams to determine long-term migration as well as a loaded exam (single leg stance) to determine inducible displacement. Differences between cemented and cementless groups were evaluated with the Mann Whitney U test and Spearman's rank correlation coefficients were calculated for early and late migrations. Significance was set at p < 0.05. Results. Seventy-five subjects were available for long-term follow-up, with average time since surgery of 12 years. This cohort contained 51 women and 24 men with cemented tibial components in 53 cases (37 female) and cementless tibial components in 22 cases (14 female). At the time of surgery, the subjects were 62±7 years old with BMIs of 33±6 m/kg2 (mean±standard deviation). Median migration at the long-term follow-up was 0.6 mm (MTPM; range 0.2–2.8 mm) and was not different between the cemented and cementless groups (p = 0.9, Mann Whitney U Test). Inducible displacement at 10 years was significantly lower for the cementless implants (p<0.001, Figure 1). Migration at one, two, and 10 years did not correlate with inducible displacement at 10 years. However, migration at one year and two years did correlate with long-term migration, with the strongest correlation at two years (Spearman's rank correlation coefficient for all components = 0.74, p < 0.001, Figure 2). Conclusion. Although long-term migration was not different for cemented or cementless (porous metal monoblock) tibial components, inducible displacement at the 10-year visit was significantly lower for these cementless components, suggesting superior fixation. Additionally, long-term migration was strongly correlated to two-year migration, regardless of fixation. These findings support the predictive value of short-term migration in determining long-term fixation. For any figures or tables, please contact authors directly


Bone & Joint Open
Vol. 5, Issue 1 | Pages 20 - 27
17 Jan 2024
Turgeon TR Vasarhelyi E Howard J Teeter M Righolt CH Gascoyne T Bohm E

Aims

A novel enhanced cement fixation (EF) tibial implant with deeper cement pockets and a more roughened bonding surface was released to market for an existing total knee arthroplasty (TKA) system.This randomized controlled trial assessed fixation of the both the EF (ATTUNE S+) and standard (Std; ATTUNE S) using radiostereometric analysis.

Methods

Overall, 50 subjects were randomized (21 EF-TKA and 23 Std-TKA in the final analysis), and had follow-up visits at six weeks, and six, 12, and 24 months to assess migration of the tibial component. Low viscosity bone cement with tobramycin was used in a standardized fashion for all subjects. Patient-reported outcome measure data was captured at preoperative and all postoperative visits.


The Bone & Joint Journal
Vol. 106-B, Issue 5 | Pages 435 - 441
1 May 2024
Angelomenos V Mohaddes M Kärrholm J Malchau H Shareghi B Itayem R

Aims

Refobacin Bone Cement R and Palacos R + G bone cement were introduced to replace the original cement Refobacin Palacos R in 2005. Both cements were assumed to behave in a biomechanically similar fashion to the original cement. The primary aim of this study was to compare the migration of a polished triple-tapered femoral stem fixed with either Refobacin Bone Cement R or Palacos R + G bone cement. Repeated radiostereometric analysis was used to measure migration of the femoral head centre. The secondary aims were evaluation of cement mantle, stem positioning, and patient-reported outcome measures.

Methods

Overall, 75 patients were included in the study and 71 were available at two years postoperatively. Prior to surgery, they were randomized to one of the three combinations studied: Palacos cement with use of the Optivac mixing system, Refobacin with use of the Optivac system, and Refobacin with use of the Optipac system. Cemented MS30 stems and cemented Exceed acetabular components were used in all hips. Postoperative radiographs were used to assess the quality of the cement mantle according to Barrack et al, and the position and migration of the femoral stem. Harris Hip Score, Oxford Hip Score, Forgotten Joint Score, and University of California, Los Angeles Activity Scale were collected.


Orthopaedic Proceedings
Vol. 90-B, Issue SUPP_I | Pages 34 - 34
1 Mar 2008
Thistlethwaite P Ronsky J Gill H
Full Access

Roentgen stereophotogrammetric analysis (RSA) is a tool that can provide quantitative information for objective evaluation and comparison of implant migration. The purpose of this study was to develop and validate a new method to determine the position and orientation of an implant with RSA that does not require the implant modification or acquisition of accurate 3D implant models. This method utilizes information from certain common features of implant geometry. This method has demonstrated in-vitro precision and accuracy of 0.005 !0.059 mm in position and 0.09 ! 0.166° in orientation which is equivalent to both marker and model based RSA methods. Roentgen stereophotogrammetric analysis (RSA) is a tool that can provide quantitative information for objective evaluation and comparison of implant migration. RSA measures have demonstrated the ability to both predict premature implant failure before clinical or standard radiological signs appear, and to elucidate implant wear which is considered a major causal factor in failure. To provide this functionality, RSA requires either the modification of each implant by the addition of spherical markers or the acquisition of accurate 3D models of each implant. These approaches can significantly limit the application of the RSA method. The purpose of this study was to develop and validate a new method to determine the position and orientation of an implant with RSA that does not require the modifying or acquiring accurate 3D models of each implant. This method is based on the geometric inter-relationship between the pair of RSA images and geometric information from the projected outlines of certain paired (visible in both views) features of implant geometry. Evaluations were performed on a metallic acetabular cup modified with spherical markers. The implant features used in this case where the hemispherical shell and the planar circle at the base of the acetabular cup. This method has demonstrated an average in-vitro precision and accuracy of 0.005 !0.059 mm in position and 0.09 ! 0.166° in orientation which was equivalent to that achieved with the marker based method and equivalent to published model based RSA results. Funding: NSERC, GEOIDE, University of Calgary


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_1 | Pages 28 - 28
1 Jan 2018
Bizot P Buisson X
Full Access

Ceramic on ceramic (CoC) Total Hip Replacement revisions give specific problems and no consensus is made on the way to perform it. The aim of this study was to report the results of THA CoC revisions and to identify the specific concerns. Between April 2007 and May 2016, 50 consecutive revisions have been performed on average 2.8 years after the THA, in 46 patients (28 males, 18 females) at a mean age of 55 years. The main reasons for revision were loosening (34%), pain without loosening (20%), infection (12%), implant breakage (10%), and instability (8%). There were 41 implant revisions, five revisions without implant change (10%) and four revisions for head change (8%). Revisions were performed without bone reconstruction in 68% of hips and with a CoC couple in 83% of hips. Three patients have died and three were lost to follow up. There were six intraoperative femoral fractures, one early and two late non−recurrent dislocations. Eight hips (16%) had re−revision with implant replacement. At a mean follow-up of 5.5 years, the mean PMA, Harris and WOMAC scores were 14.8, 72 and 23. 80% of patients were satisfied of the procedure and 89% were ready to re-do the surgery if necessary. 16% of hips experienced a noise. There were no complete lucent lines, no osteolysis, and no implant migration. Wear was not measurable. The 6-year survival rate was 82 % and 90 % if the end-point was implant revision for any cause and for fixation failure, respectively. CoC THA failure mainly affects a young population and occurs early. Failure is not wear-related but possibly related to inadequate technique. It is often possible to perform THA revision without any bone graft, using standard implants and CoC couple, provided the implants are matched


The Bone & Joint Journal
Vol. 106-B, Issue 3 | Pages 293 - 302
1 Mar 2024
Vogt B Lueckingsmeier M Gosheger G Laufer A Toporowski G Antfang C Roedl R Frommer A

Aims

As an alternative to external fixators, intramedullary lengthening nails (ILNs) can be employed for distraction osteogenesis. While previous studies have demonstrated that typical complications of external devices, such as soft-tissue tethering, and pin site infection can be avoided with ILNs, there is a lack of studies that exclusively investigated tibial distraction osteogenesis with motorized ILNs inserted via an antegrade approach.

Methods

A total of 58 patients (median age 17 years (interquartile range (IQR) 15 to 21)) treated by unilateral tibial distraction osteogenesis for a median leg length discrepancy of 41 mm (IQR 34 to 53), and nine patients with disproportionate short stature treated by bilateral simultaneous tibial distraction osteogenesis, with magnetically controlled motorized ILNs inserted via an antegrade approach, were retrospectively analyzed. The median follow-up was 37 months (IQR 30 to 51). Outcome measurements were accuracy, precision, reliability, bone healing, complications, and patient-reported outcome assessed by the Limb Deformity-Scoliosis Research Society Score (LD-SRS-30).


The Bone & Joint Journal
Vol. 106-B, Issue 6 | Pages 540 - 547
1 Jun 2024
Nandra RS Elnahal WA Mayne A Brash L McBryde CW Treacy RBC

Aims

The Birmingham Hip Resurfacing (BHR) was introduced in 1997 to address the needs of young active patients using a historically proven large-diameter metal-on-metal (MoM) bearing. A single designer surgeon’s consecutive series of 130 patients (144 hips) was previously reported at five and ten years, reporting three and ten failures, respectively. The aim of this study was to extend the follow-up of this original cohort at 25 years.

Methods

The study extends the reporting on the first consecutive 144 resurfacing procedures in 130 patients for all indications. All operations were undertaken between August 1997 and May 1998. The mean age at operation was 52.1 years (SD 9.93; 17 to 76), and included 37 female patients (28.5%). Failure was defined as revision of either component for any reason. Kaplan-Meier survival analysis was performed. Routine follow-up with serum metal ion levels, radiographs, and Oxford Hip Scores (OHSs) was undertaken.


Bone & Joint Open
Vol. 5, Issue 4 | Pages 260 - 268
1 Apr 2024
Broekhuis D Meurs WMH Kaptein BL Karunaratne S Carey Smith RL Sommerville S Boyle R Nelissen RGHH

Aims

Custom triflange acetabular components (CTACs) play an important role in reconstructive orthopaedic surgery, particularly in revision total hip arthroplasty (rTHA) and pelvic tumour resection procedures. Accurate CTAC positioning is essential to successful surgical outcomes. While prior studies have explored CTAC positioning in rTHA, research focusing on tumour cases and implant flange positioning precision remains limited. Additionally, the impact of intraoperative navigation on positioning accuracy warrants further investigation. This study assesses CTAC positioning accuracy in tumour resection and rTHA cases, focusing on the differences between preoperative planning and postoperative implant positions.

Methods

A multicentre observational cohort study in Australia between February 2017 and March 2021 included consecutive patients undergoing acetabular reconstruction with CTACs in rTHA (Paprosky 3A/3B defects) or tumour resection (including Enneking P2 peri-acetabular area). Of 103 eligible patients (104 hips), 34 patients (35 hips) were analyzed.


Orthopaedic Proceedings
Vol. 84-B, Issue SUPP_II | Pages 152 - 152
1 Jul 2002
Phillips NJ Wilkinson JM Stockley I
Full Access

We aimed to determine whether the EBRA method had greater precision and sensitivity for measuring implant migration following total hip arthroplasty (THA) than direct plain radiographic techniques using modern measuring tools. Short-term precision was evaluated in 20 subjects following THA. Consecutive, standardised radiographs of the hip were performed on the same day after repositioning. Prosthetic cup and stem migration were measured from the plain radiographs using a digital calliper following methods described by Ianotti, Malchau, Nunn, Sutherland and Wetherall, and compared to those made using EBRA. Precision was expressed as 95% confidence interval (95%CI = 1.96x Std.dev.). 10 subjects were then followed prospectively with standardised plain radiographs at baseline, 6,12 and 26 weeks after THA. Migration measurements made using EBRA were compared to those made using the most precise plain radiographic method. The 95%CI of all EBRA cup and stem measurements was ±1mm or smaller. Only the Sutherland method had a similar level of precision (95%CI ±1.11 to 1.28 mm: F-Test P> 0.05; all other method comparisons with EBRA P< 0.05). In the longitudinal study cup cranial migration of 0.53 mm (SEM 0.19) and stem subsidence of 1.53 mm (SEM 0.19) were detected using EBRA (2-way ANOVA by rank; P< 0.05 and P< 0.001 respectively). No statistically significant migration of the cup or stem was detected using the Sutherland method. The EBRA method is a precise method for describing implant migration in small groups of patients in the early period following THA, and manual methods lack sufficient precision to be used for this purpose


Orthopaedic Proceedings
Vol. 90-B, Issue SUPP_I | Pages 24 - 24
1 Mar 2008
Wilkinson J
Full Access

Aseptic loosening arises when periprosthetic bone loss results in mechanical failure at the host-implant interface, and is the main factor limiting implant survival after total hip arthroplasty (THA). The aims of this study were to determine whether genetic variation is a risk factor for loosening, explore the metabolic mechanisms of periprosthetic bone loss, and determine whether bisphosphonates may prevent bone loss and enhance implant mechanical stability after THA. In a genetic association study (. J Bone Mineral Res. 2003. ; . 18. :. 1995. –2001. ) we found that carriage of the −238A allele within the promoter region of the TNF gene was an independent risk factor for aseptic loosening. A subsequent reporter gene assay showed differential TNF gene responsiveness between the –238A and –238G alleles to polyethylene particule stimulation (Calcified Tissue Int 2003; 72: 251-273). In a cross-sectional study (J Orthop Res 2003; 214: 691–696) we found that subjects with aseptic loosening had lower bone mineral density (BMD) in the region of the femoral calcar and higher urinary excretion of cross-linked collagen breakdown products than their counterparts with fixed femoral implants. In a randomised controlled trial we found that a single dose infusion of a bisphosphonate (pamidronate) reduced femoral bone loss over 2 years after THA, but did not affect pelvic bone loss or implant migration (. J Bone Miner Res. 2002. ; . 17. : . 1328. ). Transient increases in bone turnover markers occurred after surgery and were highly predictive of later femoral BMD change. The main predictor of early implant migration was patient age, but not periprosthetic BMD change. In summary, genetic as well as environmental factors affect implant survival after THA. Aseptic loosening is associated with regional changes in bone mass and turnover as well as focal osteolytic lesions. Bisphosphonate therapy is well tolerated after THA and has a clear biological effect. However, the impact of preventing early bone loss on late aseptic loosening remains unclear and awaits long term study. [Winner, Robert Jones Gold Medal and Association Prize, 2003]


The Bone & Joint Journal
Vol. 104-B, Issue 8 | Pages 929 - 937
1 Aug 2022
Gurung B Liu P Harris PDR Sagi A Field RE Sochart DH Tucker K Asopa V

Aims

Total hip arthroplasty (THA) and total knee arthroplasty (TKA) are common orthopaedic procedures requiring postoperative radiographs to confirm implant positioning and identify complications. Artificial intelligence (AI)-based image analysis has the potential to automate this postoperative surveillance. The aim of this study was to prepare a scoping review to investigate how AI is being used in the analysis of radiographs following THA and TKA, and how accurate these tools are.

Methods

The Embase, MEDLINE, and PubMed libraries were systematically searched to identify relevant articles. The Preferred Reporting Items for Systematic Reviews and Meta-Analyses extension for scoping reviews and Arksey and O’Malley framework were followed. Study quality was assessed using a modified Methodological Index for Non-Randomized Studies tool. AI performance was reported using either the area under the curve (AUC) or accuracy.


The Bone & Joint Journal
Vol. 104-B, Issue 10 | Pages 1132 - 1141
1 Oct 2022
Holm-Glad T Røkkum M Röhrl SM Roness S Godang K Reigstad O

Aims

To analyze the short-term outcome of two types of total wrist arthroplasty (TWA) in terms of wrist function, migration, and periprosthetic bone behaviour.

Methods

A total of 40 patients suffering from non-rheumatoid wrist arthritis were enrolled in a randomized controlled trial comparing the ReMotion and Motec TWAs. Patient-rated and functional outcomes, radiological changes, blood metal ion levels, migration measured by model-based radiostereometric analysis (RSA), bone mineral density (BMD) measured by dual-energy X-ray absorptiometry (DXA), complications, loosening, and revision rates at two years were compared.


The Bone & Joint Journal
Vol. 105-B, Issue 1 | Pages 35 - 46
1 Jan 2023
Mills K Wymenga AB Bénard MR Kaptein BL Defoort KC van Hellemondt GG Heesterbeek PJC

Aims

The aim of this study was to compare a bicruciate-retaining (BCR) total knee arthroplasty (TKA) with a posterior cruciate-retaining (CR) TKA design in terms of kinematics, measured using fluoroscopy and stability as micromotion using radiostereometric analysis (RSA).

Methods

A total of 40 patients with end-stage osteoarthritis were included in this randomized controlled trial. All patients performed a step-up and lunge task in front of a monoplane fluoroscope one year postoperatively. Femorotibial contact point (CP) locations were determined at every flexion angle and compared between the groups. RSA images were taken at baseline, six weeks, three, six, 12, and 24 months postoperatively. Clinical and functional outcomes were compared postoperatively for two years.


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_IV | Pages 515 - 515
1 Oct 2010
Friedl G Aigner R Radl R Rehak P Windhager R
Full Access

Despite great progress in implant design, materials and new implantation techniques aseptic loosening is still the most frequent cause of implant failure in THA, which was found to be increased especially in patients with osteonecrosis of the femoral head (ON-FH). While a direct link between aseptic loosening and periprosthetic bone loss still remains elusive, there is plentiful evidence for a close association with early migration of implant components. Although the beneficial effect of bisphonates on periprosthetic bone mass is well established, little is known to date about their effects on implant migration. This is an important issue, because successful prevention of early implant migration would provide strong evidence of a beneficial effect on the survival rate of THA. Previously, Krismer et al. found that a total migration of the cup of ≥ 1mm and a subsidence of ≥ 1.5mm 2 years after surgery was highly predictive for aseptic implant failure of THA within 8 to 10 years. Fifty patients with end-stage ON-FH were consecutively enrolled to receive either 4mg of ZOL or saline solution (CTR) in a double-blind fashion. Radiographs standardized for EBRA-digital analysis were performed at each follow-up exam at 7 weeks, 6 months, 1 year, and yearly thereafter. The minimum follow-up period was 2 years (median follow-up: 2.8 years). Migration of the acetabular and femoral components was analyzed with the EBRA-digital software (University of Inns-bruck, Austria) independently by 3 investigators fully blinded to randomization. Within the placebo group, distal migration of the stem (subsidence) steadily increased up to −1.2mm ± 0.6 SD at 2 years after THA without reaching a plateau phase (P< 0.001, Friedman ANOVA). Less but a nearly curvilinear migration pattern was found for the acetabular components, with a transverse migration of 0.6mm ± 1.0 SD and a vertical migration of 0.6mm ± 0.8 SD at 2 years (P< 0.001, Friedman ANOVA). Treatment with ZOL effectively minimized the migration of cups in both the transverse and vertical direction (0.15 mm ± 0.6 SD and 0.06 mm ± 0.6 SD, respectively, P< 0.05, ANOVA), and a trend to a decreased subsidence was also found for stem migration (−0.91 mm ± 0.51 SD; P=0.11, ANOVA). In addition, total cup migration exceeding 1mm at 2 years was significantly reduced by ZOL in 8 patients (12 vs 4 in CTR vs ZOL, respectively) as was also found in 6 patients for subsidence (≥ 1.5mm in 9 vs 3 patients in CTR vs ZOL, respectively) (P< 0.05, Fisher’s exact). This is the first clinical trial reporting that a single infusion of ZOL suffices to improve initial implant fixation in THA. Based on best evidence available to date, this new concept shows great promise of improving the long-term outcome in THA and should be given attention in long-term trial