Results 1 - 35 of 35
Results per page:
Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_13 | Pages 30 - 30
1 Dec 2022
Lohre R Lobo A Bois A Pollock J Lapner P Athwal G Goel D
Full Access

Glenoid baseplate orientation in reverse shoulder arthroplasty (RSA) influences clinical outcomes, complications, and failure rates. Novel technologies have been produced to decrease performance heterogeneity of low and high-volume surgeons. This study aimed to determine novice and experienced shoulder surgeon's ability to accurately characterise glenoid component orientation in an intra-operative scenario.

Glenoid baseplates were implanted in eight fresh frozen cadavers by novice surgical trainees. Glenoid baseplate version, inclination, augment rotation, and superior-inferior centre of rotation (COR) offset were then measured using in-person visual assessments by novice and experienced shoulder surgeons immediately after implantation. Glenoid orientation parameters were then measured using 3D CT scans with digitally reconstructed radiographs (DRRs) by two independent observers. Bland-Altman plots were produced to determine the accuracy of glenoid orientation using standard intraoperative assessment compared to postoperative 3D CT scan results.

Visual assessment of glenoid baseplate orientation showed “poor” to “fair” correlation to 3D CT DRR measurements for both novice and experienced surgeon groups for all measured parameters. There was a clinically relevant, large discrepancy between intra-operative visual assessments and 3D CT DRR measurements for all parameters. Errors in visual assessment of up to 19.2 degrees of inclination and 8mm supero-inferior COR offset occurred. Experienced surgeons had greater measurement error than novices for all measured parameters.

Intra-operative measurement errors in glenoid placement may reach unacceptable clinical limits. Kinesthetic input during implantation likely improves orientation understanding and has implications for hands-on learning.


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_13 | Pages 37 - 37
1 Dec 2022
Fleet C de Casson FB Urvoy M Chaoui J Johnson JA Athwal G
Full Access

Knowledge of the premorbid glenoid shape and the morphological changes the bone undergoes in patients with glenohumeral arthritis can improve surgical outcomes in total and reverse shoulder arthroplasty. Several studies have previously used scapular statistical shape models (SSMs) to predict premorbid glenoid shape and evaluate glenoid erosion properties. However, current literature suggests no studies have used scapular SSMs to examine the changes in glenoid surface area in patients with glenohumeral arthritis. Therefore, the purpose of this study was to compare the glenoid articular surface area between pathologic glenoid cavities from patients with glenohumeral arthritis and their predicted premorbid shape using a scapular SSM. Furthermore, this study compared pathologic glenoid surface area with that from virtually eroded glenoid models created without influence from internal bone remodelling activity and osteophyte formation. It was hypothesized that the pathologic glenoid cavities would exhibit the greatest glenoid surface area despite the eroded nature of the glenoid and the medialization, which in a vault shape, should logically result in less surface area.

Computer tomography (CT) scans from 20 patients exhibiting type A2 glenoid erosion according to the Walch classification [Walch et al., 1999] were obtained. A scapular SSM was used to predict the premorbid glenoid shape for each scapula. The scapula and humerus from each patient were automatically segmented and exported as 3D object files along with the scapular SSM from a pre-operative planning software. Each scapula and a copy of its corresponding SSM were aligned using the coracoid, lateral edge of the acromion, inferior glenoid tubercule, scapular notch, and the trigonum spinae. Points were then digitized on both the pathologic humeral and glenoid surfaces and were used in an iterative closest point (ICP) algorithm in MATLAB (MathWorks, Natick, MA, USA) to align the humerus with the glenoid surface. A Boolean subtraction was then performed between the scapular SSM and the humerus to create a virtual erosion in the scapular SSM that matched the erosion orientation of the pathologic glenoid. This led to the development of three distinct glenoid models for each patient: premorbid, pathologic, and virtually eroded (Fig. 1). The glenoid surface area from each model was then determined using 3-Matic (Materialise, Leuven, Belgium).

Figure 1. (A) Premorbid glenoid model, (B) pathologic glenoid model, and (C) virtually eroded glenoid model.

The average glenoid surface area for the pathologic scapular models was 70% greater compared to the premorbid glenoid models (P < 0 .001). Furthermore, the surface area of the virtual glenoid erosions was 6.4% lower on average compared to the premorbid glenoid surface area (P=0.361).

The larger surface area values observed in the pathologic glenoid cavities suggests that sufficient bone remodelling exists at the periphery of the glenoid bone in patients exhibiting A2 type glenohumeral arthritis. This is further supported by the large difference in glenoid surface area between the pathologic and virtually eroded glenoid cavities as the virtually eroded models only considered humeral anatomy when creating the erosion.

For any figures or tables, please contact the authors directly.


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_12 | Pages 79 - 79
1 Dec 2022
Langohr GD Mahaffy M Athwal G Johnson JA
Full Access

Patients receiving reverse total shoulder arthroplasty (RTSA) often have osseous erosions because of glenohumeral arthritis, leading to increased surgical complexity. Glenoid implant fixation is a primary predictor of the success of RTSA and affects micromotion at the bone-implant interface. Augmented implants which incorporate specific geometry to address superior erosion are currently available, but the clinical outcomes of these implants are still considered short-term. The objective of this study was to investigate micromotion at the glenoid-baseplate interface for a standard, 3 mm and 6 mm lateralized baseplates, half-wedge, and full-wedge baseplates. It was hypothesized that the mechanism of load distribution from the baseplate to the glenoid will differ between implants, and these varying mechanisms will affect overall baseplate micromotion.

Clinical CT scans of seven shoulders (mean age 69 years, 10°-19° glenoid inclinations) that were classified as having E2-type glenoid erosions were used to generate 3D scapula models using MIMICS image processing software (Materialise, Belgium) with a 0.75 mm mesh size. Each scapula was then repeatedly virtually reconstructed with the five implant types (standard,3mm,6mm lateralized, and half/full wedge; Fig.1) positioned in neutral version and inclination with full backside contact. The reconstructed scapulae were then imported into ABAQUS (SIMULIA, U.S.) finite element software and loads were applied simulating 15°,30°,45°,60°,75°, and 90° of abduction based on published instrumented in-vivo implant data. The micromotion normal and tangential to the bone surface, and effective load transfer area were recorded for each implant and abduction angle. A repeated measures ANOVA was used to perform statistical analysis.

Maximum normal micromotion was found to be significantly less when using the standard baseplate (5±4 μm), as opposed to the full-wedge (16±7 μm, p=0.004), 3 mm lateralized (10±6 μm, p=0.017), and 6 mm lateralized (16±8 μm, p=0.007) baseplates (Fig.2). The half-wedge baseplate (11±7 μm) also produced significantly less micromotion than the full-wedge (p=0.003), and the 3 mm lateralized produced less micromotion than the full wedge (p=0.026) and 6 mm lateralized (p=0.003). Similarly, maximum tangential micromotion was found to be significantly less when using the standard baseplate (7±4 μm), as opposed to the half-wedge (12±5 μm, p=0.014), 3 mm lateralized (10±5 μm, p=0.003), and 6 mm lateralized (13±6 μm, p=0.003) baseplates (Fig.2). The full wedge (11±3 μm), half-wedge, and 3 mm lateralized baseplate also produced significantly less micromotion than the 6 mm lateralized (p=0.027, p=012, p=0.02, respectively). Both normal and tangential micromotion were highest at the 30° and 45° abduction angles (Fig.2). The effective load transfer area (ELTA) was lowest for the full wedge, followed by the half wedge, 6mm, 3mm, and standard baseplates (Fig.3) and increased with abduction angle.

Glenoid baseplates with reduced lateralization and flat backside geometries resulted in the best outcomes with regards to normal and tangential micromotion. However, these types of implants are not always feasible due to the required amount of bone removal, and medialization of the bone-implant interface. Future work should study the acceptable levels of bone removal for patients with E-type glenoid erosion and the corresponding best implant selections for such cases.

For any figures or tables, please contact the authors directly.


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_12 | Pages 85 - 85
1 Dec 2022
Fleet C McNeil D Trenholm JAI Johnson JA Athwal G
Full Access

Massive irreparable rotator cuff tears often lead to superior migration of the humeral head, which can markedly impair glenohumeral kinematics and function. Although treatments currently exist for treating such pathology, no clear choice exists for the middle-aged patient demographic. Therefore, a metallic subacromial implant was developed for the purpose of restoring normal glenohumeral kinematics and function. The objective of this study was to determine this implant's ability in restoring normal humeral head position. It was hypothesized that (1) the implant would restore near normal humeral head position and (2) the implant shape could be optimized to improve restoration of the normal humeral head position.

A titanium implant was designed and 3D printed. It consisted of four design variables that varied in both implant thickness (5mm and 8mm) and curvature of the humeral articulating surface (high constraint and low constraint. To assess these different designs, these implants were sequentially assessed in a cadaver-based biomechanical testing protocol. Eight cadaver specimens (64 ± 13 years old) were loaded at 0, 30, and 60 degrees of glenohumeral abduction using a previously developed shoulder simulator. An 80N load was equally distributed across all three deltoid heads while a 10N load was applied to each rotator cuff muscle. Testing states included a fully intact rotator cuff state, a posterosuperior massive rotator cuff tear state (cuff deficient state), and the four implant designs. An optical tracking system (Northern Digital, Ontario, Canada) was used to record the translation of the humeral head relative to the glenoid in both superior-inferior and anterior-posterior directions.

Superior-Inferior Translation

The creation of a posterosuperior massive rotator cuff tear resulted in significant superior translation of the humeral head relative to the intact cuff state (P=0.016). No significant differences were observed between each implant design and the intact cuff state as all implants decreased the superior migration of the humeral head that was observed in the cuff deficient state. On average, the 5mm low and high constraint implant models were most effective at restoring normal humeral head position to that of the intact cuff state (-1.3 ± 2.0mm, P=0.223; and −1.5 ± 2.3mm, P=0.928 respectively).

Anterior-Posterior Translation

No significant differences were observed across all test states for anterior-posterior translation of the humeral head. The cuff deficient on average resulted in posterior translation of the humeral head, however, this was not statistically significant (P=0.128). Both low and high constraint implant designs were found to be most effective at restoring humeral head position to that of the intact cuff state, on average resulting in a small anterior offset (5mm high constraint: 2.0 ± 4.7mm, P=1.000; 8mm high constraint: 1.6 ± 4.9mm, P=1.000).

The 5mm high constraint implant was most effective in restoring normal humeral head position in both the superior-inferior and anterior-posterior directions. The results from this study suggest the implant may be an effective treatment for restoring normal glenohumeral kinematics and function in patients with massive irreparable rotator cuff tears. Future studies are needed to address the mechanical efficiency related to arm abduction which is a significant issue related to patient outcomes.


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_8 | Pages 27 - 27
1 Aug 2020
Abdic S Athwal G Wittman T Walch G Raiss P
Full Access

The use of shorter humeral stems in reverse shoulder arthroplasty has been reported as safe and effective. Shorter stems are purported to be bone preserving, easy to revise, and have reduced surgical time. However, a frequent radiographic finding with the use of uncemented short stems is stress shielding. Smaller stem diameters reduce stress shielding, however, carry the risk of varus or valgus malalignment in the metadiaphyseal region of the proximal humerus. The aim of this retrospective radiographic study was to measure the true post-operative neck-shaft (N-S) angle of a curved short stem with a recommended implantation angle of 145°.

True anteroposterior radiographs of patients who received RTSA using an Ascend Flex short stem at three specialized shoulder centres (London, ON, Canada, Lyon, France, Munich, Germany) were reviewed. Radiographs that showed the uncemented stem and humeral tray in orthogonal view without rotation were included. Sixteen patients with proximal humeral fractures or revision surgeries were excluded. This yielded a cohort of 124 implant cases for analysis (122 patients, 42 male, 80 female) at a mean age of 74 years (range, 48 – 91 years). The indications for RTSA were rotator cuff deficient shoulders (cuff tear arthropathy, massive cuff tears, osteoarthritis with cuff insufficiency) in 78 patients (63%), primary osteoarthritis in 41 (33%), and rheumatoid arthritis in 5 (4%).

The humeral component longitudinal axis was measured in degrees and defined as neutral if the value fell within ±5° of the humeral axis. Angle values >5° and < 5 ° were defined as valgus and varus, respectively. The filling-ratio of the implant within the humeral shaft was measured at the level of the metaphysis (FRmet) and diaphysis (FRdia). Measurements were conducted by two independent examiners (SA and TW). To test for conformity of observers, the intraclass correlation coefficient (ICC) was calculated.

The inter- and intra-observer reliability was excellent (ICC = 0.965, 95% confidence interval [CI], 0.911– 0.986). The average difference between the humeral shaft axis and the humeral component longitudinal axis was 3.8° ± 2.8° (range, 0.2° – 13.2°) corresponding to a true mean N-S angle of 149° ± 3° in valgus. Stem axis was neutral in 70% (n=90) of implants. Of the 34 malaligned implants, 82% (n=28) were in valgus (mean N-S angle 153° ± 2°) and 18% (n=6) in varus position (mean N-S angle 139° ± 1°). The average FRmet and FRdiawere 0.68 ± 0.11 and 0.72 ± 0.11, respectively. No association was found between stem diameter and filling ratios (FRmet, FRdia) or cortical contact with the stem (r = 0.39).

Operative technique and implant design affect the ultimate positioning of the implant in the proximal humerus. This study has shown, that in uncemented short stem implants, neutral axial alignment was achieved in 70% of cases, while the majority of malaligned humeral components (86%) were implanted in valgus, corresponding to a greater than 145° neck shaft angle of the implant. It is important for surgeons to understand that axial malalignment of a short stem implant does influence the true neck shaft angle.


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_6 | Pages 27 - 27
1 Jul 2020
Smith C Athwal G Ferreira L Matache B
Full Access

Glenoid replacement is a manual bone removal procedure that can be difficult for surgeons to perform. Surgical robotics have been utilized successfully in hip and knee orthopaedic procedures but there are no systems currently available in the shoulder. These robots tend to have low adoption rates by surgeons due to high costs, disruption of surgical workflow and added complexity. As well, these systems typically use optical tracking which needs a constant line-of-sight which is not conducive to a crowded operating room. The purpose of this work was developing and testing a surgical robotic system for glenoid replacement.

The new surgical system utilizes flexible components that tether a Stewart Platform robot to the patient through a patient specific 3D printed mount. As the robot moves relative to the bone, reaction loads from the flexible components bending are measured by a load cell allowing the robot to “feel” its way around. As well, a small bone burring tool was attached to the robot to facilitate the necessary bone removal. The surgical system was tested against a fellowship-trained surgeon performing standard surgical techniques. Both the robot and the surgeon performed glenoid replacement on two different scapula analogs: standard anatomy and posterior glenoid edge wear referred to as a Walch B2. Six of each scapula model was tested by the robot and the surgeon. The surgeon created a pre-operative plan for both scapula analogs as a target for both methodologies. CT scans of the post-operative cemented implants were compared to the pre-operative target and implant position and orientation errors were measured.

For the standard shoulder analogs the net implant position and orientation errors were 1.47 ± 0.48 mm and 2.57 ± 2.30° for the robot and 1.61 ± 0.29 mm and 5.04 ± 1.92° for the surgeon respectively. For the B2 shoulders, the net implant position and orientation errors were 2.16 ± 0.36 mm and 2.89 ± 0.88° for the robot and 3.01 ± 0.42 mm and 4.54 ± 1.49° for the surgeon respectively.

The new tracking system was shown to be able to match or outperform the surgeon in most metrics. The surgeon tended to have difficulty gauging the depth needed as well as the face rotation of the implant. This was not surprising as the reaming tool used by the surgeon obscures the view of the anatomy and the spherical cutter hinders the ability to index the tool. The robot utilized only one surgical tool, the bone burr, precluding the need for multiple instruments used by the surgeon to prepare the glenoid bone bed. The force-space navigation method can be generalized to other joints, however, further work is needed to validate the system using cadaveric specimens.


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_6 | Pages 71 - 71
1 Jul 2020
Mahaffy M Athwal G Johnson J Knowles N Berkmortel C Abdic S Walch G
Full Access

This study examined the regional variations of cortical and cancellous bone density present in superiorly eroded glenoids. It is hypothesized that eroded regions will contain denser bone in response to localized stress. The shift in natural joint articulation may also cause bone resorption in areas opposite the erosion site.

Clinical CT scans were obtained for 32 shoulders (10m/22f, mean age 72.9yrs, 56–88yrs) classified as having E2-type glenoid erosion. The glenoid was divided into four measurement regions - anterior, inferior, posterior, and superior - as well as five depth regions. Depth regions were segmented in two-millimeter increments from zero to 10 millimeters, beginning at the center of the glenoid surface. A repeated-measures multiple analysis of variance (RM-MANOVA) was performed using SPSS statistical software to look for differences and interactions between mean densities in each depth, quadrant, and between genders. A second RM-MANOVA was performed to examine effects of gender and quadrant on cortical to cancellous bone volume ratios. Significance was set at p < 0 .05.

Quadrant and depth variables showed significant multivariate main effects (p 0.147 respectively). Quadrant, depth, and their interaction showed significant univariate main effects for cortical bone (p≤0.001) and cancellous bone (p < 0 .001). The lowest bone density was found to be in the inferior quadrant for cancellous bone (307±50 HU, p < 0 .001). The superior quadrant contained the highest mean density for cortical bone (895±97 HU), however it was only significantly different than in the posterior quadrant (865±97 HU, p=0.022). As for depth, it was found that cortical bone is most dense at the glenoid surface (zero to two millimeters, 892±91 HU) when compared to bone at two to eight millimeters in depth (p < 0 .02). Cancellous bone was also most dense at the surface (352±51 HU), but only compared to the eight to 10 millimeters depth (p=0.005). Cancellous bone density was found to decrease with increasing depth. For cortical-to-cancellous bone volume ratios, the inferior quadrant (0.37±0.28) had a significantly lower ratio than all other quadrants (p < 0 .001)

The superoposterior region of the glenoid was found to have denser cancellous bone and a high ratio of cortical to cancellous bone, likely due to decreased formation of cancellous bone and increased formation of cortical bone, in response to localized stresses. The inferior quadrant was found to have the least dense cortical and cancellous bone, and the lowest volume of cortical bone relative to cancellous bone. Once again, this is likely due to reduction in microstrain responsible for bone adaptation via Wolff's law. The density values found in this study generally agree with the range of values found in previous studies of normal and arthritic glenoids. An important limitation of this study is the sizing of measurement regions. For a patient with a smaller glenoid, a depth measurement of two millimeters may represent a larger portion of the overall glenoid vault. Segments could be scaled for each patient based on a percentage of each individual's glenoid size.


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_6 | Pages 97 - 97
1 Jul 2020
Khan M Liu EY Hildebrand AH Athwal G Alolabi B Horner N
Full Access

Heterotopic Ossification (HO) is a known complication that can arise after total elbow arthroplasty (TEA). In most cases it is asymptomatic, however, in some patients it can limit range of motion and lead to poor outcomes. The objective of this review was to assess and report incidence, risk factors, prophylaxis, and management of HO after TEA.

A systematic search was conducted using MEDLINE, EMBASE, and PubMed to retrieve all relevant studies evaluating occurrence of HO after TEA. The search was performed in duplicate and a quality assessment was performed of all included studies.

A total of 1907 studies were retrieved of which 45 studies were included involving 2256 TEA patients. HO was radiographically present in 10% of patients and was symptomatic in 3%. Less than 1% of patients went on to surgical excision of HO, with outcomes following surgery reported as good or excellent as assessed by range of motion and Mayo Elbow Performance Scores (MEPS). TEA due to ankylosis, primary osteoarthritis, and posttraumatic arthritis are more likely to develop symptomatic HO.

HO is an uncommon complication following TEA with the majority of patients developing HO being asymptomatic and requiring no surgical management. Routine HO prophylaxis for TEA is not supported by the literature. The effectiveness of prophylaxis in high risk patients is uncertain and future studies are required to clarify its usefulness. The strength of these conclusions are limited by inconsistent reporting in the available literature.


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_7 | Pages 52 - 52
1 Jul 2020
Abdic S Knowles N Johnson J Walch G Athwal G
Full Access

Superiorly eroded glenoids in cuff tear arthropathy represent a surgical challenge for reconstruction. The bone loss orientation and severity may influence glenoid component fixation. This computed-tomography study quantifies both the degree of erosion and orientation in superiorly eroded Favard E2 glenoids. We hypothesized that the erosion in E2 glenoids does not occur purely superiorly, rather, it is oriented in a predictable posterosuperior orientation with a largely semicircular line of erosion.

Three-dimensional reconstructions of 40 shoulders with E2 glenoids (28 female, 12 male patients) at a mean age of 74 years (range, 56–88 years) were created from computed-tomography images. Point coordinates were extracted from each construct to analyze the morphologic structure. The anatomical location of the supra- and infraglenoid tubercle guided the creation of a superoinferior axis, against which the orientation angle of the erosion was measured. The direction and, thus, orientation of erosion was calculated as a vector. By placing ten point coordinates along the line of erosion and creating a circle of best fit, the radius of the circle was placed orthogonally against a chord that resulted by connecting the two outermost points along the line of erosion. To quantify the extent of curvature of the line of erosion between the paleo- and neoglenoid, the length of the radius of the circle of best fit was calculated. Individual values were compared against the mean of circle radii. The area of bony erosion (neoglenoid), was calculated as a percentage of the total glenoid area (neoglenoid + paleoglenoid). The severity of the erosion was categorized as mild (0% to 33%), moderate (34% to 66%), and severe erosion (>66%).

The mean orientation angle between the vector of bony erosion and the superoinferior axis of the glenoid was 47° ± 17° (range, 14° – 74°) located in the posterosuperior quadrant of the glenoid, resulting in the average erosion being directed between the 10 and 11 o'clock position (right shoulder).

In 63% of E2 cases, the line of erosion separating the paleo- and neoglenoids was more curved than the average of all bony erosions in the cohort. The mean surface area of the neoglenoid was 636 ± 247 mm2(range, 233 – 1,333 mm2) and of the paleoglenoid 311 ± 165 mm2(range, 123 – 820 mm2), revealing that, on average, the neoglenoids consume 67% of the total glenoid surface. The extent of erosion of the total cohort was subdivided into one mild (2%), 14 moderate (35%) and 25 severe (62%) cases.

Using a clock-face for orientation, the average orientation of type E2 glenoid defects was directed between the 10 and 11 o'clock position in a right shoulder, corresponding to the posterosuperior glenoid quadrant. Surgeons managing patients with E2 type glenoids should be aware that a superiorly described glenoid erosion is oriented in the posterosuperior quadrant on the glenoid clock-face when viewed intra-operatively. Additionally, the line of erosion in 63% of E2 glenoids is substantially curved, having a significant effect on bone removal techniques when using commercially available augments for defect reconstruction.


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_1 | Pages 139 - 139
1 Feb 2020
Soltanmohammadi P Willing R Athwal G
Full Access

Introduction

Stress shielding of bone around the stem components of total shoulder replacement (TSR) implants can result in bone resorption, leading to loosening and failure. Titanium is an ideal biomaterial for implant stems; however, it is much stiffer than bone. Recent advances in additive manufacturing (AM) have enabled the production of parts with complex geometries from titanium alloys, such as hollow or porous stems. The objective of this computational study is to determine if hollow titanium stems can reduce stress shielding at the proximal humerus. We hypothesize that hollow TSR implant stems will reduce stress shielding in comparison with solid stems and the inner wall thickness of the hollow stem will be a design parameter with a direct effect on bone stresses.

Methods

Using a previously developed statistical shape and density model (SSDM) of the humerus based on 75 cadaveric shoulders, a simulated average CT image was created. Using MITK-GEM, the cortical and trabecular bones were segmented from this CT image and meshed with quadratic tetrahedral elements. Trabecular bone was modeled as an isotropic and inhomogeneous material, with the Young's modulus defined element-by-element based on the corresponding CT densities. Cortical bone was assumed isotropic with a uniform Young's modulus of 20 GPa. The Poisson's ratio for all bone was 0.3. The distal humerus was fully constrained. Bone stresses were calculated by performing finite element analyses in ABAQUS with a 320 N force and 2 Nm frictional moment applied to the articular surface of the humeral head, based on an in vivo study during 45 degrees of shoulder abduction. Subsequently, the humeral head was resected and reamed to receive solid- and hollow-stemmed implants with identical external geometries but three different inner wall thicknesses (Figure 1). The identical surrounding bone meshes for the intact and reconstructed bones allowed element-by-element stress comparisons. The volume-weighted average changes in cortical and trabecular bone von Mises stresses were calculated, (wrt the intact humerus), as well as the percentage of bone volume experiencing a relative increase or decrease in stress greater than 10%.


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_1 | Pages 22 - 22
1 Feb 2020
Van De Kleut M Athwal G Yuan X Teeter M
Full Access

Introduction

Reverse total shoulder arthroplasty (RTSA) is rapidly being adopted as the standard procedure for a growing number of shoulder arthropathies. Though short-term outcomes are promising, mid- and long-term follow-ups present a number of complications – among them, humeral stem and glenosphere component loosening. Though not the primary complication, previously reported aseptic loosening required revision in 100% of cases. As the number of patients undergoing RTSA increases, especially in the younger population, it is important for surgeons to identify and utilize prostheses with stable long-term fixation. It has previously been shown in the hip and knee literature that implant migration in the first two years following surgery is predictive of later failure due to loosening in the 5=10-year postoperative window. The purpose of this study is to, for the first time, evaluate the pattern and total magnitude of implant migration in reverse shoulder arthroplasty using the gold standard imaging technique radiostereometric analysis (RSA).

Methods

Forty patients were prospectively randomized to receive either a cemented or press-fit humeral stem, and a glenosphere secured to the glenoid with either autologous bone graft or 3D printed porous titanium for primary reverse total shoulder arthroplasty. Following surgery, participants are imaged using RSA, a calibrated, stereo x-ray technique. Radiographs are acquired at 6 weeks (baseline), 3 months, 6 months, 1 year, and 2 years. Migration of the humeral stem and glenosphere at each time point is compared to baseline. Migration of the prostheses is independently compared between humeral stem fixation groups and glenosphere fixation groups using a two-way repeated measures ANOVA with Tukey's test for multiple comparisons.


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_2 | Pages 41 - 41
1 Feb 2020
Studders C Saliken D Shirzadi H Athwal G Giles J
Full Access

INTRODUCTION

Reverse shoulder arthroplasty (RSA) provides an effective alternative to anatomic shoulder replacements for individuals with cuff tear arthropathy, but certain osteoarthritic glenoid deformities make it challenging to achieve sufficient long term fixation. To compensate for bone loss, increase available bone stock, and lateralize the glenohumeral joint center of rotation, bony increased offset RSA (BIO-RSA) uses a cancellous autograft for baseplate augmentation that is harvested prior to humeral head resection. The motivations for this computational study are twofold: finite element (FE) studies of BIO-RSA are absent from the literature, and guidance in the literature on screw orientations that achieve optimal fixation varies. This study computationally evaluates how screw configuration affects BIO-RSA graft micromotion relative to the implant baseplate and glenoid.

METHODS

A senior shoulder specialist (GSA) selected a scapula with a Walch Type B2 deformity from patient CT scans. DICOM images were converted to a 3D model, which underwent simulated BIO-RSA with three screw configurations: 2 divergent superior & inferior locking screws with 2 convergent anterior & posterior compression screws (SILS); 2 convergent anterior & posterior locking screws and 2 superior & inferior compression screws parallel to the baseplate central peg (APLS); and 2 divergent superior & inferior locking screws and 2 divergent anterior & posterior compression screws (AD). The scapula was assigned heterogeneous bone material properties based on the DICOM images’ Hounsfield unit (HU) values, and other components were assigned homogenous properties. Models were then imported into an FE program for analysis. Anterior-posterior and superior-inferior point loads and a lateral-medial distributed load simulated physiologic loading. Micromotion data between the RSA baseplate and bone graft as well as between the bone graft and glenoid were sub-divided into four quadrants.


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_1 | Pages 23 - 23
1 Feb 2020
Van De Kleut M Athwal G Yuan X Teeter M
Full Access

Introduction

Reverse total shoulder arthroplasty (RTSA) is a semi-constrained joint replacement with an articulating cobalt-chromium glenosphere and ultra-high molecular weight polyethylene (PE). Because of its limited load bearing, surgeons and implant manufacturers have not elicited the use of highly cross-linked PE in the shoulder, and to date have not considered excessive PE wear in the reverse shoulder a primary concern. As the number of shoulder procedures is expected to grow exponentially in the next decade, however, it is important to evaluate how new designs and bearing materials interact and to have an understanding of what is normal in well-functioning joint replacements. Currently, no in vivo investigation into RTSA PE wear has been conducted, with limited retrieval and simulation studies. In vitro and in silico studies demonstrate a large range in expected wear rates, from 14.3 mm3/million cycles (MC) to 126 mm3/MC, with no obvious relationship between wear rate and polyethylene diameter. The purpose of this study is to evaluate, for the first time, both volumetric and linear wear rates in reverse shoulder patients, with a minimum six-year follow-up using stereo radiographic techniques.

Methods

To date, seven patients with a self-reported well-functioning Aequalis Reversed II (Wright Medical Group, Edina, MN, USA) RTSA implant system have been imaged (mean years from surgery = 7.0, range = 6.2 to 9). Using stereo radiographs, patients were imaged at the extents of their range of motion in internal and external rotation, lateral abduction, forward flexion, and with their arm at the side. Multiple arm positions were used to account for the multiple wear vectors associated with activities of daily living and the shoulder's six degrees of motion. Using proprietary software, the position and orientation of the polyethylene and glenosphere components were identified and their transformation matrices recorded. These transformation matrices were then applied to the CAD models of each component, respectively, and the apparent intersection of the glenosphere into the PE recorded. Using previously validated in-house software, volumetric and maximum linear wear depth measurements were obtained. Linear regression was used to identify wear rates.


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_4 | Pages 14 - 14
1 Apr 2019
Van De Kleut M Athwal G Yuan X Teeter M
Full Access

Introduction

Total shoulder arthroplasty is the fastest growing joint replacement in recent years, with projected compound annual growth rates of 10% for 2016 through 2021 – higher than those of both the hip and knee combined. Reverse total shoulder arthroplasty (RTSA) has gained particular interest as a solution for patients with irreparable massive rotator cuff tears and failed conventional shoulder replacement, for whom no satisfactory intervention previously existed. As the number of indications for RTSA continues to grow, so do implant designs, configurations, and fixation techniques. It has previously been shown that continuous implant migration within the first two years postoperatively is predictive of later loosening and failure in the hip and knee, with aseptic loosening of implant components a guaranteed cause for revision in the reverse shoulder. By identifying implants with a tendency to migrate, they can be eliminated from clinical practice prior to widespread use. The purpose of this study is to, for the first time, evaluate the pattern and magnitude of implant component migration in RTSA using the gold standard imaging technique radiostereometric analysis (RSA).

Methods

Forty patients were prospectively randomized to receive either a cemented or press-fit humeral stem, and a glenosphere secured to the glenoid with either autologous bone graft or 3D printed porous titanium (Aequalis Ascend Flex, Wright Medical Group, Memphis, TN, USA) for primary reverse total shoulder arthroplasty. Following surgery, partients are imaged using RSA, a calibrated, stereo x-ray technique, at 6 weeks (baseline), 3 months, 6 months, 1 year, and 2 years.

Migration of the humeral stem and glenosphere at each time point is compared to baseline. Preliminary results are presented, with 15 patients having reached the 6-month time point by presentation.


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_5 | Pages 52 - 52
1 Apr 2019
Knowles NK Raniga S West E Ferreira L Athwal G
Full Access

Introduction

The Walch Type B2 glenoid has the hallmark features of posteroinferior glenoid erosion, retroversion, and posterior humeral head subluxation. Although our understanding of the pathoanatomy of bone loss and its evolution in Type B's has improved, the etiology remains unclear. Furthermore, the morphology of the humerus in Walch B types has not been studied. The purpose of this imaging based anthropometric study was to examine the humeral torsion in Walch Type B2 shoulders. We hypothesized that there would be a compensatory decrease in humeral retroversion in Walch B2 glenoids.

Methods

Three-dimensional models of the full length humerus were generated from computed tomography data of normal cadaveric (n = 59) and Walch Type B shoulders (n = 59). An anatomical coordinate system referencing the medial and lateral epicondyles was created for each model. A simulated humeral head osteotomy plane was created and used to determine humeral version relative to the epicondylar axis and the head-neck angle. Measurements were repeated by two experienced fellowship-trained shoulder surgeons to determine inter-rater reliability. Glenoid parameters (version, inclination and 2D critical shoulder angle) and posterior humeral head subluxation were calculated in the Type B group to determine the pathologic glenohumeral relationship. Two-way ANOVAs compared group and sex within humeral version and head-neck angle, and intra-class correlation coefficients (ICCs) with a 2-way random effects model and absolute agreement were used for inter-rater reliability.


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_5 | Pages 51 - 51
1 Apr 2019
Knowles NK Kusins J Columbus M Athwal G Ferreira L
Full Access

Introduction

Mechanical property relationships used in the computational modeling of bones are most often derived using mechanical testing of normal cadaveric bone. However, a significant percentage of patients undergoing joint arthroplasties exhibit some form of pathologic bone disease, such as osteoarthritis. As such, the objective of this study was to compare the micro-architecture and apparent modulus (Eapp) of humeral trabecular bone in normal cadaveric specimens and bone extracted from patients undergoing total shoulder arthroplasty.

Methods

Micro-CT scans were acquired at 20 µm spatial resolution for humeral heads from non-pathologic cadavers (n=12) and patients undergoing total shoulder arthroplasty (n=10). Virtual cylindrical cores were extracted along the medial-lateral direction. Custom-code was used to generate micro finite element models (µFEMs) with hexahedral elements. Each µFEM was assigned either a homogeneous tissue modulus of 20 GPa or a heterogeneous tissue modulus scaled by CT- intensity. Simulated compression to 0.5% apparent strain was performed in the medial-lateral direction. Morphometric parameters and apparent modulus-bone volume fraction relationships were compared between groups.


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_6 | Pages 13 - 13
1 Apr 2018
Knowles N Langohr G Athwal G Ferreira L
Full Access

BACKGROUND

Stability of the glenoid component is essential to ensure successful long-term outcomes following Total shoulder arthroplasty (TSA), and may be improved through better glenoid component design. As such, this study assessed identical all-polyethylene glenoid components stability, having various fixation types, using component micromotion under simulated joint loading in an osteoarthritic patient cohort.

METHODS

Five all-polyethylene glenoid component designs were compared (Keel, Central-Finned 4-Peg, Peripheral 4-Peg, Cross-Keel, and Inverted-Y). A cement mantle surrounded each fixation type, except the Central-Finned 4-Peg which was surrounded by bone. The humeral component had a non-conforming radius of curvature. Scapular models of six type A1 osteoarthritic male patients (mean: 61 years old, range: 48 to 76 years old) were assigned heterogeneous bone properties based on CT intensity. Each of the 30 scapula models were truncated and fully constrained on the medial scapular border. The bone/cement interface was fully bonded, and the fixation feature/cement interface was frictionally constrained. A ‘worst case’ load magnitude of 125% BW of a 50th percentile male was used. A purely compressive load was applied to the center of the glenoid component, followed by superior, superior-posterior, posterior, inferior-posterior, and inferior loads. Stability of the glenoid component based solely on the fixation type was determined using the mean and maximum normal (liftoff) and tangential (sliding) micromotion in six regions of the glenoid component.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_6 | Pages 93 - 93
1 Mar 2017
West E Knowles N Ferreira L Athwal G
Full Access

Introduction

Shoulder arthroplasty is used to treat several common pathologies of the shoulder, including osteoarthritis, post-traumatic arthritis, and avascular necrosis. In replacement of the humeral head, modular components allow for anatomical variations, including retroversion angle and head-neck angle. Surgical options include an anatomic cut or a guide-assisted cut at a fixed retroversion and head-neck angle, which can vary the dimensions of the cut humeral head (height, anteroposterior (AP), and superoinferior (SI) diameters) and lead to negative long term clinical results. This study measures the effect of guide-assisted osteotomies on humeral head dimensions compared to anatomic dimensions.

Methods

Computed tomography (CT) scans from 20 cadaveric shoulder specimens (10 male, 10 female; 10 left) were converted to three-dimensional models using medical imaging software. An anatomic humeral head cut plane was placed at the anatomic head – neck junction of all shoulders by a fellowship trained shoulder surgeon. Cut planes were generated for each of the standard implant head-neck angles (125°, 130°, 135°, and 140°) and retroversion angles (20°, 30°, and 40°) in commercial cutting guides. Each cut plane was positioned to favour the anterior humeral head-neck junction while preserving the posterior cuff insertion. The humeral head height and diameter were measured in both the AP plane and the SI plane for the anatomic and guide-assisted osteotomy planes. Differences were compared using separate two-way repeated measures ANOVA for each dependent variable and deviations were shown using box plot and whisker diagrams.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_6 | Pages 94 - 94
1 Mar 2017
West E Knowles N Athwal G Ferreira L
Full Access

Background

Humeral version is the twist angle of the humeral head relative to the distal humerus. Pre-operatively, it is most commonly measured referencing the transepicondylar axis, although various techniques are described in literature (Matsumura et al. 2014, Edelson 1999, Boileau et al., 2008). Accurate estimation of the version angle is important for humeral head osteotomy in preparation for shoulder arthroplasty, as deviations from native version can result in prosthesis malalignment. Most humeral head osteotomy guides instruct the surgeon to reference the ulnar axis with the elbow flexed at 90°. Average version values have been reported at 17.6° relative to the transepicondylar axis and 28.8° relative to the ulnar axis (Hernigou, Duparc, and Hernigou 2014), although it is highly variable and has been reported to range from 10° to 55° (Pearl and Volk 1999). These studies used 2D CT images; however, 2D has been shown to be unreliable for many glenohumeral measurements (Terrier 2015, Jacxsens 2015, Budge 2011). Three-dimensional (3D) modeling is now widely available and may improve the accuracy of version measurements. This study evaluated the effects of sex and measurement system on 3D version measurements made using the transepicondylar and ulnar axis methods, and additionally a flexion-extension axis commonly used in biomechanics.

Methods

Computed tomography (CT) scans of 51 cadaveric shoulders (26 male, 25 female; 32 left) were converted to 3D models using medical imaging software. The ulna was reduced to 90° flexion to replicate the arm position during intra-operative version measurement. Geometry was extracted to determine landmarks and co-ordinate systems for the humeral long axis, epicondylar axis, flexion-extension axis (centered through the capitellum and trochlear groove), and ulnar long axis. An anatomic humeral head cut plane was placed at the head-neck junction of all shoulders by a fellowship trained shoulder surgeon. Retroversion was measured with custom Matlab code that analysed the humeral head cut plane relative to a reference system based on the long axis of the humerus and each elbow axis. Effects of measurement systems were analyzed using separate 1-way RM ANOVAs for males and females. Sex differences were analyzed using unpaired t-tests for each measurement system.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_3 | Pages 111 - 111
1 Feb 2017
Elwell J Athwal G Willing R
Full Access

Introduction

Reverse total shoulder arthroplasty (RTSA) can partially restore lost range of motion (ROM). Active motion restoration is largely a function of RTSA joint constraint, limiting impingement, and muscle recruitment; however, it may also be a function of implant design. The aim of this computational study was to examine the effects of implant design parameters, such as neck-shaft (N-S) angle and glenoid lateralization, on impingement-free global circumduction range of motion (GC-ROM). GC-ROM summarizes the characteristically complex, wide-ranging envelope of glenohumeral motion into a single quantity for ease of comparison.

Methods

Nine computational models were used to investigate implant parameters. The parameters examined were N-S angles of 135°, 145°, and 155° in combination with glenoid lateralizations (0, 5, and 10 mm). Static positioning of the humerus was defined by an elevation direction angle, elevation angle, and rotation. The humerus was rotated from the neutral position (0° of rotation and elevation), and then elevated in different elevation directions until impingement was detected. Abduction occurred at an elevation direction angle of 0°, while flexion and extension occurred at elevation direction angles of 90° and −90°, respectively. Elevation direction angles ranged from −180° to 180°. Elevation ranged from 0° and 180°. Rotations ranged from −45° to 90°, where negative and positive rotations represented external and internal rotation, respectively. For each rotation angle, a plot of maximum elevation in each elevation plane was created using polar coordinates (radius = elevation, angle = elevation direction). The area enclosed by the resulting points, normalized with respect to the implant with a 145° N-S angle and 5 mm lateralization, was calculated. The sum of these areas defined the GC-ROM.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_4 | Pages 3 - 3
1 Feb 2017
Gupta A Knowles N Ferreira L Athwal G
Full Access

Background

Glenoid baseplate fixation for reverse shoulder arthroplasty relies on the presence of sufficient bone stock and quality. Glenoid bone may be deficient in cases of primary erosions or due to bone loss in the setting of revision arthroplasty. In such cases, the best available bone for primary baseplate fixation usually lies within the three columns of the scapula. The purpose of this study was to characterise the relationship of the three columns of the scapula independent of glenoid anatomy and to establish the differences between male and female scapular anatomy.

Methods

Fifty cadaveric scapulae (25 male, 25 female) were analysed using CT-based imaging software. The surface geometries of the coracoid, scapular spine and inferior scapular column were delineated in the sagittal plane. A linear best-fit line was drawn to establish the long axis of each column independent of the glenoid. The width of the glenoid was measured and points marked at the midpoint of each measurement. A best-fit line starting at the supra glenoid tubercle passing through the midpoints was chosen as the superior inferior (SI) axis of the glenoid.

An orthogonal plane to the scapular plane was developed parallel to the glenoid face. The axis representing each of the three columns of the scapula and the SI axis of the glenoid, were projected onto this plane. The relationship between each column was analysed with respect to each other and with respect to the SI glenoid axis. Thus, measurements obtained gave the relationships of the three columns of the scapula (independent of the glenoid) and their relationships to the long axis of the glenoid (dependant on the glenoid). Comparisons were made between males and females using the independent t-tests.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_21 | Pages 5 - 5
1 Dec 2016
Holmes S Diaz A Athwal G Faber K O'Gorman D
Full Access

Propionibacterium acnes infection of the shoulder after arthroplasty is a common complication. Current detection methodologies for P. acnes involve prolonged anaerobic cultures that can take up to three weeks before findings can be reported. Our aim was to develop a polymerase chain reaction-restriction fragment length polymorphism (PCR-RFLP) approach that is both sensitive and specific to P. acnes that would enable a 24-hour turnaround between biopsy and results.

Comparisons between the 16S ribosomal sequences of P. acnes and closely related bacteria identified two unique regions in P.acnes to which PCR primers were designed. Additionally, two unique restriction enzyme cut sites for HaeIII were identified within this amplicon. To test the PCR method, arthroscopic surgical biopsies were mechanically homogenised and boiled for 20 minutes to lyse the cellular membranes. PCR was performed using standard conditions followed by a one hour HaeIII enzymatic digest of the PCR product. Resultant fragments were visualised on polyacrylamide gels stained with ethidium bromide. All experiments included no-template controls to rule out reagent contamination and independently confirmed P. acnes DNA as a positive control. Serial dilutions of P. acnes cultures in Robertson's cooked-meat broth and spectrophotometric analysis of cellular concentration were used to assess the sensitivity of the PCR reaction.

A unique 564 base-pair PCR amplicon was derived from different strains of P. acnes. This amplicon was confirmed as P. acnes DNA by gel excision and DNA sequencing. HaeIII digests of the amplicon yielded 3 restriction fragments at the sizes predicted by in silico analyses. Sensitivity testing confirmed that as few as 10 P. acnes cells in a 50µl reaction volume could be detected using this assay. P. acnes was also detected in surgical biopsy samples.

P. acnes infections following shoulder arthroplasty are a serious complication placing a burden on the healthcare system and the patient due to the lengthy surgical revision process that follows. The infections are also difficult to diagnose. This unique assay combines the sensitivity of PCR with the specificity of RFLP mapping to specifically identify P. acnes in surgical isolates. We anticipate that this assay will allow us to determine if a biopsy is P. acnes positive within 24-hours of sampling, allowing for more aggressive antibiotic therapy and monitoring to avoid implant failure and revision surgery. Additionally, this PCR-RFLP method may decrease the false positive rate of extended length cultures due to P. acnes contamination.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_21 | Pages 6 - 6
1 Dec 2016
Langohr G Giles J Johnson J Athwal G
Full Access

Despite reverse total shoulder arthroplasty (RTSA) being primarily indicated for massive rotator cuff tears, it is often possible to repair portions of the infraspinatus and subscapularis of patients undergoing this procedure. However, there is disagreement regarding whether these tissues should be repaired, as their effects remain unclear. Therefore, we investigated the effects of rotator cuff repair and changes in humeral and glenosphere lateralisation (HLat & GLat) on deltoid and joint loading.

Six shoulders were tested on an in-vitro muscle driven active motion simulator. Cuff tear arthropathy was simulated in each specimen, which was then implanted with a custom adjustable RTSA fitted with a six axis load sensor. We assessed the effects of 4 RTSA configurations (i.e. all combinations of 0&10mm of HLat & GLat) on deltoid force, joint load, and joint load angle during abduction with/out rotator cuff repair. Deltoid and joint loads recorded by the load cell are reported as a % of Body Weight (%BW). Repeated measures ANOVAs and pairwise comparisons were performed with p<0.05 indicating significance.

Cuff repair interacted with HLat & GLat (p=0.005, Fig. 1) such that with no HLat, GLat increased deltoid force without cuff repair (8.1±2.1%BW, p=0.012) and this effect was significantly increased with cuff repair (12.8±3.2%BW, p=0.010). However, adding HLat mitigated this such that differences were not significant. HLat and GLat affected deltoid force regardless of cuff status (−2.5±0.7%BW, p=0.016 & +7.7±2.3%BW, p=0.016, respectively). Rotator cuff repair did significantly increase joint load (+11.9±2.1%BW, p=0.002), as did GLat (+13.3±1.5%BW, p<0.001).

The increases in deltoid and joint load caused by rotator cuff repair confirm that it acts as an adductor following RTSA and increases deltoid work. Additionally, cuff repair's negative effects are exacerbated by GLat, which strengthens its adduction affect, while Hlat increases the deltoid's abduction effect thus mitigating the cuff's antagonistic effects. Cuff repair increases concavity compression within the joint; however, Hlat produces a similar effect by wrapping the deltoid around the greater tuberosity – which redirects its force – and does so without increasing the magnitude of muscle and joint loading. The long-term effects of increased joint loading due to rotator cuff repair are unknown, however, it can be postulated that it may increase implant wear, and the risk of deltoid fatigue. Therefore, RTSA implant designs which improve joint compression without increasing muscle and joint loading may be preferable to rotator cuff repair.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_21 | Pages 10 - 10
1 Dec 2016
West E Knowles N Ferreira L Athwal G
Full Access

Shoulder arthroplasty is used to treat osteoarthritis, post-traumatic arthritis, and avascular necrosis. Modular components allow for natural variability in shoulder anatomy, including retroversion and head-neck angles. Surgical options include anatomic or guide-assisted cut at a fixed retroversion and head-neck angle. The purpose of this study was to determine the variability between head height (HH) and anteroposterior (AP) and superoinferior (SI) diameters using anatomic and guide-assisted humeral head cuts.

Computed tomography scans of 10 cadaveric shoulder specimens (5 male, 5 female) were converted to 3D models. An anatomic humeral head cut plane was placed at the anatomic head–neck junction maintaining the posterior cuff insertion for all shoulders by a fellowship trained shoulder surgeon. Cut planes were generated for standard implant head neck angles (125°,130°,135°, and 140°) and retroversion angles (20°,30°, and 40°) in commercial cutting guides, for a combination of 12 repeated cut conditions per specimen. The humeral HH and the head diameter were measured in the AP and the SI planes for anatomic and guide-assisted osteotomy planes. Differences were compared using a separate two-way repeated measures ANOVA for each dependent variable.

Guide-assisted cuts showed no significant effect on HH due to head-neck (p=0.205) or retroversion angles (p=0.190). These results persisted by gender (male: head-neck p=0.659 and retroversion p=0.386; female: head-neck p=0.204 and retroversion p=0.190). SI diameter increased by 1.3 mm with increasing head-neck angle (p<0.001), but there was no effect due to retroversion (p=0.148). A head-neck angle of 125° caused the greatest decrease in SI diameter of −2.8 mm compared to the anatomic cut, averaged over the retroversion range. The greatest reduction of SI diameter, −3.4 mm compared to anatomic, occurred with 125° head-neck angle and 20° retroversion. By gender, males showed a significant effect from head-neck angle (p=0.008), but females did not (p=0.077). There was no significant difference from retroversion in either gender group (male p=0.792; female p=0.057). There was no significant difference in AP diameter by head-neck (p=0.192) or retroversion angles (p=0.168). These results persisted in the males (head-neck p=0.420 and retroversion p=0.780). In females, there was no effect from head-neck angle (p=0.232); however, retroversion angle trended toward significance (p=0.050).

For patients whose natural anatomy falls outside the range of the commercial cut guides, templated resection may result in deviation from natural humeral head dimensions. Due to the large variability in anatomic retroversion and head-neck angles in the subjects of this study, further study with a larger sample size is needed to investigate observed trends. These preliminary results have implications for manufacturers to create guides to represent a larger segment of the population, and surgeons' intra-operative choice.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_20 | Pages 8 - 8
1 Nov 2016
Griffiths M Langohr G Athwal G Johnson J
Full Access

There are a variety of sizes currently available for reverse total shoulder arthroplasty (RTSA) implant systems. Common sizing options include a smaller 36 to 38 mm or a larger 40 to 42 mm glenosphere, and are typically selected based on surgeon preference or patient size. Previous studies have only evaluated the abduction and adduction range of motion within a single plane of elevation, providing a limited view of the joint's possible range of motion. The purpose of this study was to use computer modeling to evaluate the abduction and adduction range of motion across multiple planes of elevation for a range of glenosphere sizes.

Computed tomography images of four cadaveric specimens (age: 54 ± 24 years) were used to obtain the osseous anatomy to be utilised in the model. Solid-body motion studies of the RTSA models were constructed with varying glenosphere diameters of 33, 36, 39, 42, and 45 mm in Solidworks (Dassault Systems, US). The implant components were scaled, while maintaining a consistent centre of rotation. Simulations encompassing the full range of abduction and adduction were conducted for the planes of elevation between −15˚ and 135˚ at 15˚ intervals, with the motion of the humerus being constrained in neutral internal-external rotation throughout all planes. Angles of elevation were obtained utilising the humeral long axis and the RTSA centre of rotation. Statistical analysis was performed using repeated measures ANOVA.

Glenosphere diameter was found to significantly affect the adduction range of motion (p=0.043), in which the largest size provided approximately 17˚ more adduction range of motion than the smallest. However, abduction range of motion was not found to be significantly affected through the alteration of glenosphere size (p=0.449). The plane of elevation was not found to significantly affect abduction or abduction (p=0.585 & p=0.225, respectively).

Increasing glenosphere diameter resulted in an increased adduction range of motion when averaged across the tested planes of elevation; however the observed influence on abduction was not significant. These are similar to the trends observed in the previous single plane of elevation studies. These findings illustrate the importance of implant sizing related to range of motion. Further studies are required to determine the influence of glenosphere size on internal and external range of motion.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_20 | Pages 9 - 9
1 Nov 2016
Langohr G Haverstock J Johnson J Athwal G
Full Access

Shoulder arthroplasty, both primary (TSA) and reverse (RTSA), are common interventions for arthritis and cuff tear arthropathy. The effect of shoulder arthroplasty on shoulder motion is of particular interest in assessing the effectiveness of the procedure and the development and biomechanical testing of implants. A comparison of the arthroplasty shoulder to that of the non-operated contralateral shoulder provides insight into how well the reconstruction has restored natural shoulder motion. The purpose of this study was to ascertain the shoulder motion of patients who have undergone shoulder arthroplasty and to compare the motion of the reconstructed and contralateral natural sides.

Eleven human subjects (70±9yrs) who had undergone total shoulder arthroplasty wore a custom instrumented shirt for the waking hours of one day. The 3D orientation of each humeral sensor was transformed with respect to the torso to allow for the calculation of humeral elevation and plane of elevation angles. Joint angles for each subject were then discretised, and the operative and contralateral normal (control) shoulders were then compared.

The majority of both the arthroplasty and control shoulder elevation motions took place below 80° of elevation, totaling on average 1910±373 and 1887±312 motions per hour, respectively. Conversely, elevations greater than 80° were significantly less with occurrences totaling only 55±31 and 78±41 motions per hour for the arthroplasty and control shoulders, respectively (p<0.01). Both the arthroplasty and control shoulder were at elevations below 80° for 88±7% and 87±7% of the day, respectively. When the total motion of the arthroplasty and non-operative control shoulders were compared, no statistically significant difference was detected (p=0.8), although the non-operated side exhibited marginally more motion than the operated side, an effect which was larger at higher elevation angles (p=0.3).

This study provides insight into the effects of shoulder arthroplasty on thoraco-humeral motion and compares it to the non-operative side. Interestingly, there were no significant differences measured between the arthroplasty and the control side, which may demonstrate the effectiveness of reconstruction on restoring natural shoulder motion. It is interesting to note that on average, each shoulder arthroplasty elevated above 80° approximately 55 times per hour, corresponding to just under 330,000 motions per year. Similarly, when elevations greater than 60° are extrapolated, the resulting yearly motions total approximately 1.5 million cycles (Mc), which suggests that the ‘duty cycle’ of the shoulder is similar to the hip, approximated to be between 1–2 Mc per year. Arthroplasty wear simulators should be calibrated to simulate these patterns of motion, and component design may be improved by understanding the kinematics of actual shoulder motion.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_20 | Pages 52 - 52
1 Nov 2016
Ng J Nishiwaki M Gammon B Athwal G King G Johnson J
Full Access

Fracture or resection of the radial head can cause unbalance and long-term functional complications in the elbow. Studies have shown that a radial head excision can change elbow kinematics and decrease elbow stability. The radial head is also important in both valgus and varus laxity and displacement. However, the effect of radial head on ulnohumeral joint load is not known. The objective of this experimental study was to compare the axial loading produced at the ulnohumeral joint during active flexion with and without a radial head resection.

Ten cadaveric arms were used. Each specimen was prepared and secured in an elbow motion simulator. To simulate active flexion, the tendons of the biceps, brachialis, brachioradialis, and triceps were attached to servo motors. The elbow was moved through a full range of flexion. To quantify loads at the ulnohumeral joint, a load cell was implanted in the proximal ulna. Testing was conducted in the intact then radial head resected case, in supination in the horizontal, vertical, varus and valgus positions.

When comparing the average loads during flexion, the axial ulnar load in the horizontal position was 89±29N in an intact state compared to 122±46N during radial head resection. In the vertical position, the intact state produced a 67±16N load while the resected state was 78±23N. In the varus and valgus positions, intact state resulted in loads of 57±26N and 18±3N, respectively. Conversely, with a radial head resection, varus and valus positions measured 56±23N and 54±23N loads, respectively. For both joint configurations, statistical differences were observed for all flexion angles in all arm positions during active flexion (p=0.0001). When comparing arm positions and flexion angle, statistical differences were measured between valgus, horizontal and vertical (p<0.005) except for varus position (p=0.64).

Active flexion caused a variation in loads throughout flexion when comparing intact versus radial head resection. The most significant variation in ulnar loading occurred during valgus and horizontal flexion. The vertical and varus position showed little variation because the position of the arm is not affected by the loss of the radial head. However, in valgus position, the resected radial head creates a void in the joint space and, with gravity, causes greater compensatory ulnar loading. In the horizontal position, the forearm is not directly affected by gravitational pull and cannot adjust to counterbalance the resected radial head, therefore loads are localised in the ulnohumeral joint. These findings prove the importance of the radial head and that a radial head resection can overload the ulnohumeral side.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_20 | Pages 17 - 17
1 Nov 2016
Reeves J Athwal G Johnson J
Full Access

To evaluate the efficacy of using a novel button-suture construct in place of traditional screws to provide bone block fixation for the Latarjet procedure.

Four paired cadaveric shoulders (n=8) were denuded, with the exception of the conjoint tendon on the coracoid, and were potted. A 15% anterior glenoid bone defect was simulated. Right and left specimens were randomised into two groups: double-screw versus quadruple-button Latarjet reconstruction techniques. A uniaxial mechanical actuator loaded the Latarjet reconstructed glenoid articular surface via a 47mm diameter metallic hemisphere. Cyclic loading between 50–200N was applied to the glenoid at a rate of 1Hz for 1000 cycles. Testing was repeated three times for conjoint tendon loads of 0N, 10N and 20N. The relative positions of three points on the inferior, central and superior edges of the coracoid bone fragment were optically tracked with respect to a glenoid coordinate system throughout testing. Screw and button constructs were compared on the basis of maximum relative displacement at these points (RINF, RCENT, RSUP). Statistical significance was assessed using a paired-samples t-test in SPSS.

When conjoint tendon loading was not present the double screw and quadruple button constructs were not significantly (P>0.779) different (0N: RINF: 0.11 (0.05)mm vs. 0.12 (0.03)mm, RCENT: 0.12 (0.04)mm vs. 0.12 (0.03)mm, RSUP: 0.13 (0.04)mm vs. 0.12 (0.03)mm). Additionally, the double screw construct was not found to differ (P>0.062) from the quadruple button in terms of resultant coracoid displacement for all central and superior points, regardless of conjoint loading (10N: RCENT: 0.11 (0.03)mm vs. 0.19 (0.05)mm, RSUP: 0.11 (0.01)mm vs. 0.18 (0.04)mm; 20N: RCENT: 0.13 (0.01)mm vs. 0.30 (0.13)mm, RSUP: 0.13 (0.03)mm vs. 0.26 (0.14)mm). It was only for the inferior point with conjoint loading of 10N and 20N that the double screw construct began to produce significantly lower displacements than the quadruple button (10N: RINF: 0.11 (0.03)mm vs. 0.23 (0.05)mm, P=0.047; 20N: RINF: 0.12 (0.02)mm vs. 0.39 (0.15)mm, P=0.026).

The results of the screw and button constructs when conjoint tendon loading was absent suggest that the button may be a suitable substitute to the screw when the coracoid is used as a bone block. Due to the small resultant displacements (max: screw = 0.19mm, button = 0.52mm), it is suggested that buttons may also act as a substitute to screws for Latarjet procedures, provided conjoint tendon overloading is minimised during the post-operative graft healing period. These in-vitro results support the in-vivo results of Boileau et al (2015) that demonstrated the suture-button technique to be an excellent alternative to screw fixation Latarjet, with graft healing in 91% of their subjects.


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_IV | Pages 554 - 554
1 Nov 2011
Giles JW Glennie A Ferreira LM Athwal G Faber KJ Johnson JA
Full Access

Purpose: Loosening of glenoid components in total shoulder arthroplasty is a common clinical problem which can necessitate revision surgery. The mechanism of loosening is poorly understood and may relate to implant design, component fixation techniques, and interfacial tensile stresses. We are unaware of any studies that have examined the fundamental aspects of load transfer to bone for various joint loading configurations. Hence, the objective of this study was to investigate the effect of joint loading on bone strain adjacent to a poly-ethylene glenoid implant.

Method: Five specimens (4 males; avg age: 59.5 yrs) implanted with a cemented, all polyethylene component (Anatomical Shoulder; Zimmer) were tested using an apparatus capable of producing loading vectors with various angles, magnitudes and directions. Each specimen was tested using a ramp load of 0–150 N (at 10N/sec) in two directions (superior and inferior) and with six angles of load application. A uniaxial strain gauge was placed in each of the four quadrants of the glenoid, approximately 1 mm medial to the glenoid rim. The primary axis of each strain gauge was oriented medio-laterally to record bone strains. The humeral head was simulated by a custom steel ball with a radius of curvature consistent with a nonconforming humeral prosthesis.

Results: The relationship between strain and applied force was not linear (superior quadrant at 40o: linear fit R2=0.96; quadratic fit R2=0.999; p< 0.0005), and was dependent on the loading angle. During pure compressive loading, tension was observed in the superior and inferior quadrants of the glenoid; while less consistent results in the anterior and posterior quadrants revealed variable tension and compression. Superior and inferior loading each caused increasing ipsilateral tension, occurring from 0–30o and 0–20o, respectively.

Conclusion: The current study is thought to be the first to directly measure load transfer at the implant-bone interface. We demonstrated load transfer nonlinearities between a surgically implanted glenoid component and the underlying bone in all locations and for a wide range of loading conditions. This has important implications towards the modeling of these constructs using finite element analyses. The results also illustrate tensile loading during compressive and small eccentricity loading cases. These results suggest a polyethylene flexure, causing the periphery of the glenoid implant to flex upwards placing the cement mantle and underlying bone in tension. Tensile loads that are linked to cement mantle fracture and implant loosening are produced under loading conditions associated with activities of daily living. This study has provided insight into the mechanisms of load transfer between a cemented polyethylene glenoid implant and the underlying bone. Reduction or elimination of these interfacial tensile stresses around the glenoid periphery should be considered when developing novel methods for component fixation.


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_IV | Pages 570 - 570
1 Nov 2011
Chant CB MacDermid J Drosdowech DS Faber KJ Athwal G
Full Access

Purpose: The purpose of this study was to identify if preoperative pain scores predict postoperative pain and functional outcomes in patients following rotator cuff surgery and if a threshold where increased risk occurs could be established. Establishing a risk threshold may help identify patients who need increased follow-up or rehabilitation.

Method: One hundred six subjects with rotator cuff pathology requiring operative intervention were prospectively followed. The pain subscale of the Shoulder Pain and Disability Index (SPADI) was used as an indicator of pre-operative pain. Postoperative function one year following surgery was determined using the Simple Shoulder Test (SST). Scores with 40% or more deficit (compared to age matched controls) were classified as poor outcomes. The relative risk (RR) of poor SST scores was calculated across different cutoffs for preoperative pain scores.

Results: Having a high preoperative pain score was associated with a poor outcome following rotator cuff surgery at both the six month and one year followup. Preoperative pain scores did predict postoperative functional scores. As preoperative pain levels increased there was a higher risk of poor functional outcomes. The RR of having a poor SST at 1-year was 2.3, if preoperative pain score was greater than 35/50.

Conclusion: The current study indicates that those patients with high preoperative pain scores (> 35/50 or > 70%) are more than twice as likely to have a poor outcome following rotator cuff surgery. This should inform patients and surgeons for postoperative expectations. Whether closer follow-up, pre-rehabilitation, more intensive postoperative rehabilitation or enhanced pain management can alter this prognosis warrants investigation.


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_IV | Pages 569 - 569
1 Nov 2011
Razmjou H Athwal G Holtby R
Full Access

Purpose: The purpose of this study was to investigate the difference in the level of pre and 6 months post operative objective and subjective measures of disability between patients with full-thickness rotator cuff tears and those with impingement syndrome/partial thickness rotator cuff tears.

Method: This study involved a review of prospectively collected data from a consecutive series of patients who had undergone surgery related to rotator cuff pathology (acromioplasty with or without resection of clavicle for impingement syndrome/partial thickness rotator cuff tears or repair for full-thickness rotator cuff tears). Exclusion criteria included previous surgery, concomitant pathologies, and work-related injuries with an active compensation claim related to the shoulder. Standardized pre and post-operative data (history and clinical examination, including strength assessment) were collected. To measure symptoms and functional levels, all patients completed a disease-specific outcome measure, the Western Ontario Rotator Cuff (WORC) Index which explores five domains of physical symptoms, life style, work, sports, and emotions. Paired and independent non-parametric (Wilcoxon two sample tests, and Wilcoxon signed rank tests) statistics were used where normality of data were violated.

Results: Three hundred and five patients (130 women and 175 men) with a mean age of 58 years (range, 21–82) met inclusion criteria. One hundred and ninety eight (65%) patients had full-thickness rotator cuff tears and 107(35%) had impingement [59 (55%)] or partial thickness rotator cuff tears [48 (45%)]. Patients with full-thickness tears complained of greater weakness, had a higher prevalence of a specific injury such as fall on an outstretched hand, and reported a higher frequency of insidious onset of pain. The full-thickness tear group was significantly weaker in elevation both pre and post-operatively. Patients with impingement syndrome expressed more severe symptoms and more emotional disability prior to surgery and had more physical disability related to lifting and performing activities of daily living and more emotional disability 6 months after surgery. Both groups showed a statistically significant improvement in overall pain, WORC score, and strength 6 months following surgery.

Conclusion: Our results indicate that the extent of rotator cuff pathology and level of physical and emotional disability do not necessarily correlate positively in the early phase of recovery. Patients with less severe rotator cuff pathology tend to be more disabled both before and after surgery. This needs to be considered when planning for return to work and other activities and when assessing treatment outcomes.


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_III | Pages 270 - 270
1 Jul 2011
Rouleau D Athwal G Faber KJ
Full Access

Purpose: Recognition of the proximal ulna dorsal angulation (PUDA) is important for anatomic reduction of proximal ulnar fractures or osteotomies, especially when using newer straight precontoured proximal ulnar plates. The purpose of this study was to characterize the PUDA in 50 patients with bilateral elbow radiographs.

Method: Bilateral elbow radiographs (100 radiographs) were magnified four times using commercial software. The PUDA was measured from the intersection of lines tangent to the subcutaneous border of the olecranon and the proximal ulnar shaft. The olecranon tip-to-apex distance of the PUDA was also measured. Three orthopaedic surgeons independently examined the radiographs and intra/inter-observer reliability was calculated using Intra-Class-Correlation (ICC).

Results: A PUDA was present in 96% of radiographs. The average PUDA was 5.7° (range, 0°to14°). The Pearson Correlation coefficient for a side-to-side comparison was 0.86(p< 0.001). The average tip-to-apex distance was 47 mm (34 mm–78mm). No correlation was identified with sex or age. Intra-observer reliability was excellent for the PUDA (ICC 0.892 and 0.863) and good for tip-to-apex distance (ICC 0.762 and 0.827). Inter-observer reliability was good for PUDA (ICC 0.784 and 0.925) and for tip-to-apex distance (ICC 0.711 and 0.769).

Conclusion: A mean proximal ulna dorsal angulation of 5.7° is present in 96% of patients at an average of 47 mm distal to the olecranon tip. Measurement of the PUDA has good/excellent inter/intra-observer reliability. Recognition of the PUDA may be helpful in anatomic plating of the ulna. Contralateral PUDA measurements are useful for surgical planning in cases with comminution or distorted anatomy.


Orthopaedic Proceedings
Vol. 91-B, Issue SUPP_II | Pages 228 - 228
1 May 2009
Macdermid J Athwal G Drosdowech D Faber K
Full Access

This study evaluated the impact of surgical wait-list times on the functional status and productivity of patients with rotator cuff tear

Two hundred and five patients were evaluated by a blind evaluator and by self report when referred for surgical management of cuff tear (confirmed by ultrasound or MRI). Patients were assessed on a monthly basis prior to surgery (two year limit). ROM and strength were assessed by an independent evaluator; patient’s self-reported comorbidity, functional status (WORC, SST), work limitations (WLQ-26) and work lost-time. Changes in health status were assessed using repeated measures ANOVA and GLM.

The mean age of the population used was 56+/−11 years in which 74% were males and 26% females. Tear size was distributed amongst this population as small (0–1 cm {45%), moderate (1–3cm 27%), large (3–5cm 23.2%) and massive (5+cm 15%). Patients had symptoms or an average of fourteen months prior to referral. Despite this, decline in strength (p mental demands) (output demands > time management demands). Loss in productivity exceeded 15%.

Rotator cuff tear causes substantial at work-limitation and work lost time. Patients lost strength and declined in functional status while waiting for surgical repair of a torn rotator cuff. The burden of illness, while waiting for cuff repair its substantial.


Orthopaedic Proceedings
Vol. 90-B, Issue SUPP_I | Pages 140 - 140
1 Mar 2008
Rowland A Athwal G King G
Full Access

Purpose: Radial head replacement with a prosthesis that is too thick has been reported to be associated with stiffness, pain and capitellar wear. Radiographic widening of the lateral ulnohumeral joint following radial head replacement has been used as a criterion to diagnose overstuffing of the radiocapitellar joint. The purpose of this study was to show that widening of the lateral ulnohumeral joint is a normal anatomic variant and therefore cannot be used conclusively to diagnose radiocapitellar joint overstuffing.

Methods: Fifty normal standardized anteroposterior elbow radiographs from 50 patients with a mean age of 48 years were reviewed to evaluate variations in the joint space between the medial and lateral facets of the ulnohumeral joint. Using computer software at 4x magnification (GE, Fairfield, CT), two lines were drawn perpendicular to the lateral ulnohumeral joint and two lines perpendicular to the medial ulnohumeral joint. The difference in length of these two lines was used to assess how parallel the lateral and medial joint spaces are. The lengths of the two lines were averaged to compare lateral joint space thickness to medial joint space thickness.

Results: The width of the lateral ulnohumeral joint space (3.6mm & #61617; 0.8mm) was greater than the medial ulnohumeral joint space (2.8mm & #61617; 0.5mm) (p< 0.001). The lengths of the two medial joint space perpendicular lines were similar (p> 0.05), indicating the medial joint space is normally parallel. The lengths of the lateral joint space perpendicular lines were greater laterally (p= 0.02), indicating the lateral joint is not normally parallel.

Conclusions: The lateral ulnohumeral joint space is often wider than the medial ulnohumeral joint space on an anteroposteror radiograph of the normal elbow. While the medial ulnohumeral joint space is usually parallel, the lateral ulnohumeral joint space may be non-parallel and wider laterally, therefore, lateral joint space widening is not a reliable indicator of radiocapitellar joint overstuffing. A non-parallel medial ulnohumeral joint space may be suggestive of possible overstuffing of a radial head arthroplasty, however, comparison radiographs of the uninjured elbow is likely the best investigation to consider when overstuffing is suspected.


Orthopaedic Proceedings
Vol. 90-B, Issue SUPP_I | Pages 140 - 140
1 Mar 2008
Athwal G Sperling J Rispoli D Cofield R
Full Access

Purpose: Currently, there is little information available concerning the outcome of patients with infection following rotator cuff repair. Therefore, the purpose of this study was to review the incidence, management and outcomes of patients with rotator cuff repair complicated with deep infection.

Methods: Between 1975 and 2003, 39 cases of deep infection following rotator cuff repair were identified. The medical records and radiographs were retrospectively examined. At a mean follow-up of 8.2 years, seven patients had died and two patients had been lost to follow-up leaving 30 cases for outcome evaluation.

Results: The incidence of deep infection after rotator cuff repairs that were performed at our institution was 0.43% (21 of 4886 cases). The mean interval from rotator cuff repair to the time of infection diagnosis was 49 days. ESR and C-reactive protein were elevated in only 60% and 50% of patients, respectively. Propionibacterium was the most common organism isolated, infecting 51% of cases. A mean of 3.3 surgical debridements were necessary for the eradication of infection. At final follow-up, mean active abduction was 121° and mean external rotation was 44°. The ASES score averaged 67 points and the Simple Shoulder Test score averaged 7.3 points.

Conclusions: The data from this study suggests that the eradication of deep infection following rotator cuff repair is possible, however, substantial functional limitations are not unusual. Additionally, the treating surgeon should be aware of the high incidence of Propionibacterium and the importance of allowing a minimum of seven days of culture to identify this organism.