Aims. The optimal choice of management for proximal humerus fractures (PHFs) has been increasingly discussed in the literature, and this work aimed to answer the following questions: 1) what are the incidence rates of PHF in the geriatric population in the USA; 2) what is the mortality rate after PHF in the elderly population, specifically for distinct treatment procedures; and 3) what factors influence the mortality rate?. Methods. PHFs occurring between 1 January 2009 and 31 December 2019 were identified from the Medicare physician service records. Incidence rates were determined, mortality rates were calculated, and semiparametric Cox regression was applied, incorporating 23 demographic, clinical, and socioeconomic covariates, to compare the mortality risk between treatments. Results. From 2009 to 2019, the incidence decreased by 11.85% from 300.4 cases/100,000 enrollees to 266.3 cases/100,000 enrollees, although this was not statistically significant (z = -1.47, p = 0.142). In
This study was performed to determine whether
pure cancellous bone graft and Kirschner (K-) wire fixation were sufficient
to achieve bony union and restore alignment in scaphoid nonunion.
A total of 65 patients who underwent cancellous bone graft and K-wire
fixation were included in this study. The series included 61 men
and four women with a mean age of 34 years (15 to 72) and mean delay
to surgery of 28.7 months (3 to 240). The patients were divided
into an unstable group (A) and stable group (B) depending on the
pre-operative radiographs. Unstable nonunion was defined as a lateral
intrascaphoid angle >
45°, or a radiolunate angle >
10°. There were
34 cases in group A and 31 cases in group B. Bony union was achieved
in 30 patients (88.2%) in group A, and in 26 (83.9%) in group B
(p = 0.439).
We treated surgically 16 shoulders with an isolated traumatic rupture of the subscapularis tendon over a six-year period. Nine patients had a total and seven a partial tear of the subscapularis tendon. Repair was undertaken through a small deltopectoral groove approach. The mean Constant score improved in total tears from 38.7 to 89.3 points (p = 0.003) and in partial tears from 50.7 to 87.9 points (p = 0.008). The total tears were significantly more improved by surgery than the partial tears (p = 0.001). The delay between trauma and surgery was inversely proportional to the improvement in the Constant score suggesting that early diagnosis and surgical repair improves outcome.
We conducted a prospective, randomised, controlled trial of 45 patients (47 elbows), with tennis elbow, who underwent either a formal open release or a percutaneous tenotomy. All patients had pre- and post-operative assessment using the Disability of Arm, Shoulder and Hand (DASH) scoring system. Both groups were followed up for a minimum of 12 months. Statistical analyses using the Mann-Whitney U test and repeated measured ANOVA showed significant improvements for patient satisfaction (p = 0.012), time to return to work (p = 0.0001), improvements in DASH score (p = 0.001) and improvement in sporting activities (p = 0.046) in the percutaneous group. Those patients undergoing a percutaneous release returned to work on average three weeks earlier and improved significantly more quickly than those undergoing an open procedure. The percutaneous procedure is a quicker and simpler procedure to undertake and produces significantly better results.
In order to compare the outcome from surgical repair and physiotherapy, 103 patients with symptomatic small and medium-sized tears of the rotator cuff were randomly allocated to one of the two approaches. The primary outcome measure was the Constant score, and secondary outcome measures included the self-report section of the American Shoulder and Elbow Surgeons score, the Short Form 36 Health Survey and subscores for shoulder movement, pain, strength and patient satisfaction. Scores were taken at baseline and after six and 12 months by a blinded assessor. Nine patients (18%) with insufficient benefit from physiotherapy after at least 15 treatment sessions underwent secondary surgical treatment. Analysis of between-group differences showed better results for the surgery group on the Constant scale (difference 13.0 points, p − 0.002), on the American Shoulder and Elbow surgeons scale (difference 16.1 points, p <
0.0005), for pain-free abduction (difference 28.8°, p = 0.003) and for reduction in pain (difference on a visual analogue scale −1.7 cm, p <
0.0005).
The purpose of this study was to assess the long-term results (more than ten years) of two types of cemented ulnar component with type-5 Kudo total elbow arthroplasty in a consecutive series of 56 patients (60 elbows) with rheumatoid arthritis, and to compare the results in elbows above and below a Larsen grade IV. There was no radiolucency around the humeral component. Patients in whom a metal-backed ulnar component and a porous-coated stem were used had better clinical results and significantly less progression of radiolucent line formation around the ulnar component. They also had a significantly better long-term survival than patients with an all-polyethylene ulnar component. The clinical results of arthroplasty using all-polyethylene ulnar components were inferior, regardless of the degree of joint destruction. We conclude that the type-5 Kudo total elbow arthroplasty with cementless fixation of the porous-coated humeral component and cemented fixation of a metal-backed ulnar component is acceptable and well-tolerated by rheumatoid patients.
We compared the quantitative electromyographic activity of the elbow flexors during four exercises (forced inspiration, forced expiration, trunk flexion and attempted elbow flexion), following intercostal nerve transfer to the musculocutaneous nerve in 32 patients who had sustained root avulsion brachial plexus injuries. Quantitative electromyographic evaluation of the mean and maximum amplitude was repeated three times for each exercise. We found that mean and maximum elbow flexor activity was highest during trunk flexion, followed by attempted elbow flexion, forced inspiration and finally forced expiration. The difference between each group was significant (p <
0.001), with the exception of the difference between trunk flexion and attempted elbow flexion. Consequently, we recommend trunk flexion exercises to aid rehabilitation following intercostal nerve transfer.
Rotator cuff muscle atrophy and fatty infiltration affect the clinical outcomes of rotator cuff tear patients. However, there is no effective treatment for fatty infiltration at this time. High-intensity interval training (HIIT) helps to activate beige adipose tissue. The goal of this study was to test the role of HIIT in improving muscle quality in a rotator cuff tear model via the β3 adrenergic receptor (β3AR). Three-month-old C57BL/6 J mice underwent a unilateral rotator cuff injury procedure. Mice were forced to run on a treadmill with the HIIT programme during the first to sixth weeks or seventh to 12th weeks after tendon tear surgery. To study the role of β3AR, SR59230A, a selective β3AR antagonist, was administered to mice ten minutes before each exercise through intraperitoneal injection. Supraspinatus muscle, interscapular brown fat, and inguinal subcutaneous white fat were harvested at the end of the 12th week after tendon tear and analyzed biomechanically, histologically, and biochemically.Aims
Methods
This study aimed to define the histopathology of degenerated humeral head cartilage and synovial inflammation of the glenohumeral joint in patients with omarthrosis (OmA) and cuff tear arthropathy (CTA). Additionally, the potential of immunohistochemical tissue biomarkers in reflecting the degeneration status of humeral head cartilage was evaluated. Specimens of the humeral head and synovial tissue from 12 patients with OmA, seven patients with CTA, and four body donors were processed histologically for examination using different histopathological scores. Osteochondral sections were immunohistochemically stained for collagen type I, collagen type II, collagen neoepitope C1,2C, collagen type X, and osteocalcin, prior to semiquantitative analysis. Matrix metalloproteinase (MMP)-1, MMP-3, and MMP-13 levels were analyzed in synovial fluid using enzyme-linked immunosorbent assay (ELISA).Aims
Methods
The aim of this study was to create artificial intelligence (AI) software with the purpose of providing a second opinion to physicians to support distal radius fracture (DRF) detection, and to compare the accuracy of fracture detection of physicians with and without software support. The dataset consisted of 26,121 anonymized anterior-posterior (AP) and lateral standard view radiographs of the wrist, with and without DRF. The convolutional neural network (CNN) model was trained to detect the presence of a DRF by comparing the radiographs containing a fracture to the inconspicuous ones. A total of 11 physicians (six surgeons in training and five hand surgeons) assessed 200 pairs of randomly selected digital radiographs of the wrist (AP and lateral) for the presence of a DRF. The same images were first evaluated without, and then with, the support of the CNN model, and the diagnostic accuracy of the two methods was compared.Aims
Methods
An objective technological solution for tracking adherence to at-home shoulder physiotherapy is important for improving patient engagement and rehabilitation outcomes, but remains a significant challenge. The aim of this research was to evaluate performance of machine-learning (ML) methodologies for detecting and classifying inertial data collected during in-clinic and at-home shoulder physiotherapy exercise. A smartwatch was used to collect inertial data from 42 patients performing shoulder physiotherapy exercises for rotator cuff injuries in both in-clinic and at-home settings. A two-stage ML approach was used to detect out-of-distribution (OOD) data (to remove non-exercise data) and subsequently for classification of exercises. We evaluated the performance impact of grouping exercises by motion type, inclusion of non-exercise data for algorithm training, and a patient-specific approach to exercise classification. Algorithm performance was evaluated using both in-clinic and at-home data.Aims
Methods
Aims. Plating displaced proximal humeral fractures is associated with a high rate of screw perforation. Dynamization of the proximal screws might prevent these complications. The aim of this study was to develop and evaluate a new gliding screw concept for plating proximal humeral fractures biomechanically. Methods. Eight pairs of three-part humeral fractures were randomly assigned for pairwise instrumentation using either a prototype gliding plate or a standard PHILOS plate, and four pairs were fixed using the gliding plate with bone cement augmentation of its proximal screws. The specimens were cyclically tested under progressively increasing loading until perforation of a screw. Telescoping of a screw, varus tilting and screw migration were recorded using optical motion tracking. Results. Mean initial stiffness (N/mm) was 581.3 (. sd. 239.7) for the gliding plate, 631.5 (. sd. 160.0) for the PHILOS and 440.2 (. sd. 97.6) for the gliding augmented plate without significant differences between the groups (p = 0.11). Mean varus tilting (°) after 7500 cycles was comparable between the gliding plate (2.6; . sd. 1.9), PHILOS (1.2; . sd. 0.6) and gliding augmented plate (1.7; . sd. 0.9) (p = 0.10). Similarly, mean screw migration(mm) after 7500 cycles was similar between the gliding plate (3.02; . sd. 2.85), PHILOS (1.30; . sd. 0.44) and gliding augmented plate (2.83; . sd. 1.18) (p = 0.13). Mean number of cycles until failure with 5° varus tilting were 12702 (. sd. 3687) for the gliding plate, 13948 (. sd. 1295) for PHILOS and 13189 (. sd. 2647) for the gliding augmented plate without significant differences between the groups (p = 0.66). Conclusion. Biomechanically, plate fixation using a new gliding screw technology did not show considerable advantages in
Rotator cuff (RC) tears are common musculoskeletal injuries which often require surgical intervention. Noninvasive pulsed electromagnetic field (PEMF) devices have been approved for treatment of long-bone fracture nonunions and as an adjunct to lumbar and cervical spine fusion surgery. This study aimed to assess the effect of continuous PEMF on postoperative RC healing in a rat RC repair model. A total of 30 Wistar rats underwent acute bilateral supraspinatus tear and repair. A miniaturized electromagnetic device (MED) was implanted at the right shoulder and generated focused PEMF therapy. The animals’ left shoulders served as controls. Biomechanical, histological, and bone properties were assessed at three and six weeks.Aims
Methods
To evaluate if union of clavicle fractures can be predicted at six weeks post-injury by the presence of bridging callus on ultrasound. Adult patients managed nonoperatively with a displaced mid-shaft clavicle were recruited prospectively. Ultrasound evaluation of the fracture was undertaken to determine if sonographic bridging callus was present. Clinical risk factors at six weeks were used to stratify patients at high risk of nonunion with a combination of Quick Disabilities of the Arm, Shoulder and Hand questionnaire (QuickDASH) ≥ 40, fracture movement on examination, or absence of callus on radiograph.Aims
Methods
The diagnosis of chronic lesions of the rotator cuff is challenging. We have developed a new index to improve the sonographic diagnosis of chronic tears of the cuff. In a pilot study, we examined 50 asymptomatic healthy volunteers by ultrasound to establish the diameter of the rotator cuff in relation to the tendon of the long head of biceps. Subsequently, the index was calculated in 64 patients who had had shoulder pain for more than three months caused by clinically diagnosed lesions of the rotator cuff. The compensatory hypertrophy of the biceps tendon was quantified sonographically in relation to the diameter of the cuff.
A systematic search of the literature published between January 1985 and February 2006 identified 62 studies which reported the results of arthroscopic procedures for chronic anterior shoulder instability or
A consecutive series of 372 patients who underwent surgery for disorders of the rotator cuff involving arthroscopic subacromial decompression and open or arthroscopic repairs of the cuff were prospectively investigated as to the comparability of subjective and objective assessment scores of shoulder function. Assessments were made before operation and at 3, 6, 12, 18 and 24 months after surgery using the Disabilities of the Arm, Shoulder, and Hand score, the Oxford shoulder score and the Constant-Murley score, which was used as a reference. All scores were standardised to a scale of 0 to 100 for
The diagnosis of nerve injury using thermotropic liquid crystal temperature strips was compared blindly and prospectively against operative findings in 36 patients requiring surgical exploration for unilateral upper limb lacerations with suspected nerve injury. Thermotropic liquid crystal strips were applied to affected and non-affected segments in both hands in all subjects. A pilot study showed that a simple unilateral laceration without nerve injury results in a cutaneous temperature difference between limbs, but not within each limb. Thus, for detection of a nerve injury,
We randomly selected 39 patients undergoing excision of the trapezium for osteoarthritis of the first carpometacarpal joint into two groups, with mobilisation either at one or at four weeks after operation. The patients were reviewed at a median of six months (6 to 8). The clinical details, the severity of the disease and the preoperative clinical measurements of both groups were similar. Excision of the trapezium resulted in significant improvement in objective and subjective function.
We performed a neurological and radiological study of the wrists of 58 patients with Hansen’s disease and 60 age-matched healthy control subjects. Significant differences (p <
0.01) were found between the groups in the carpal glenoid sector, the radial physeal widening index, the carpal ulnar distance, the carpal index and in distal radio-ulnar discrepancy.
Osteoarthritis of the wrist is a complication of a number of common traumatic conditions. Arthrodesis of the radiocarpal joint, proximal row carpectomy and excision of the scaphoid, combined with midcarpal arthrodesis, have all been reported as surgical options. There have been no randomised studies comparing these procedures, and the feasibility of conducting this type of trial is limited. We used decision analysis to compare the three surgical techniques. The variables for the model used were based principally on data from the literature. Extensive sensitivity analyses were carried out to test the impact of the values given to these variables on the outcome of the model. The model indicated that the preferred treatment is proximal row carpectomy. Decision analysis allows a
Indocyanine green (ICG) fluorescence angiography is an emerging technique that can provide detailed anatomical information during surgery. The purpose of this study is to determine whether ICG fluorescence angiography can be used to evaluate the blood flow of the rotator cuff tendon in the clinical setting. Twenty-six patients were evaluated from October 2016 to December 2017. The participants were categorized into three groups based on their diagnoses: the rotator cuff tear group; normal rotator cuff group; and adhesive capsulitis group. After establishing a posterior standard viewing portal, intravenous administration of ICG at 0.2 mg/kg body weight was performed, and fluorescence images were recorded. The time from injection of the drug to the beginning of enhancement of the observed area was measured. The hypovascular area in the rotator cuff was evaluated, and the ratio of the hypovascular area to the anterolateral area of the rotator cuff tendon was calculated (hypovascular area ratio).Objectives
Methods
Between March 1994 and June 2003, 80 patients with brachial plexus palsy underwent a trapezius transfer. There were 11 women and 69 men with a mean age of 31 years (18 to 69). Before operation a full evaluation of muscle function in the affected arm was carried out. A completely flail arm was found in 37 patients (46%). Some peripheral function in the elbow and hand was seen in 43 (54%). No patient had full active movement of the elbow in combination with adequate function of the hand. Patients were followed up for a mean of 2.4 years (0.8 to 8). We performed the operations according to Saha’s technique, with a modification in the last 22 cases. We demonstrated a difference in the results according to the pre-operative status of the muscles and the operative technique. The transfer resulted in an increase of function in all patients and in 74 (95%) a decrease in multidirectional instability of the shoulder. The mean increase in active abduction was from 6° (0 to 45) to 34° (5 to 90) at the last review. The mean forward flexion increased from 12° (0 to 85) to 30° (5 to 90). Abduction (41°) and especially forward flexion (43°) were greater when some residual function of the pectoralis major remained (n = 32). The best results were achieved in those patients with most pre-operative power of the biceps, coracobrachialis and triceps muscles (n = 7), with a mean of 42° of abduction and 56° of forward flexion. Active abduction (28°) and forward flexion (19°) were much less in completely flail shoulders (n = 34).
The aim of this study was to compare the pain caused by the application
of a tourniquet after exsanguination of the upper limb with that
occurring after simple elevation. We used 26 healthy volunteers (52 arms), each of whom acted as
their own matched control. The primary outcome measure was the total pain experienced by
each volunteer while the tourniquet was inflated for 20 minutes.
This was calculated as the area under the pain curve for each individual
subject. Secondary outcomes were pain at each time point; the total
pain experienced during the recovery phase; the ability to tolerate the
tourniquet and the time for full recovery after deflation of the
tourniquet. Aims
Patients and Methods
The objective of this study was to perform a meta-analysis of all randomised controlled trials (RCTs) comparing surgical and non-surgical management of fractures of the proximal humerus, and to determine whether further analyses based on complexity of fracture, or the type of surgical intervention, produced disparate findings on patient outcomes. A systematic review of the literature was performed identifying all RCTs that compared surgical and non-surgical management of fractures of the proximal humerus. Meta-analysis of clinical outcomes was performed where possible. Subgroup analysis based on the type of fracture, and a sensitivity analysis based on the type of surgical intervention, were also performed.Objectives
Methods
Between 2005 and 2012, 50 patients (23 female, 27 male) with
nonunion of the humeral shaft were included in this retrospective
study. The mean age was 51.3 years (14 to 88). The patients had
a mean of 1.5 prior operations ( All patients were assessed according to a specific risk score
in order to devise an optimal and individual therapy plan consistent
with the Diamond Concept. In 32 cases (64%), a change in the osteosynthesis
to an angular stable locking compression plate was performed. According
to the individual risk an additional bone graft and/or bone morphogenetic
protein-7 (BMP-7) were applied. A successful consolidation of the nonunion was observed in 37
cases (80.4%) with a median healing time of six months (IQR 6).
Younger patients showed significantly better consolidation. Four
patients were lost to follow-up. Revision was necessary in a total
of eight (16%) cases. In the initial treatment, intramedullary nailing
was most common. Methods
Results
Traumatic brachial plexus injury causes severe functional impairment
of the arm. Elbow flexion is often affected. Nerve surgery or tendon
transfers provide the only means to obtain improved elbow flexion.
Unfortunately, the functionality of the arm often remains insufficient.
Stem cell therapy could potentially improve muscle strength and
avoid muscle-tendon transfer. This pilot study assesses the safety
and regenerative potential of autologous bone marrow-derived mononuclear
cell injection in partially denervated biceps. Nine brachial plexus patients with insufficient elbow flexion
(i.e., partial denervation) received intramuscular escalating doses
of autologous bone marrow-derived mononuclear cells, combined with
tendon transfers. Effect parameters included biceps biopsies, motor
unit analysis on needle electromyography and computerised muscle tomography,
before and after cell therapy.Objectives
Methods
To report the five-year results of a randomised controlled trial
examining the effectiveness of arthroscopic acromioplasty in the
treatment of stage II shoulder impingement syndrome. A total of 140 patients were randomly divided into two groups:
1) supervised exercise programme (n = 70, exercise group); and 2)
arthroscopic acromioplasty followed by a similar exercise programme
(n = 70, combined treatment group).Objectives
Methods
There is little published information on the
health impact of frozen shoulder. The purpose of this study was
to assess the functional and health-related quality of life outcomes
following arthroscopic capsular release (ACR) for contracture of
the shoulder. Between January 2010 and January 2012 all patients
who had failed non-operative treatment including anti-inflammatory
medication, physiotherapy and glenohumeral joint injections for
contracture of the shoulder and who subsequently underwent an ACR
were enrolled in the study. A total of 100 patients were eligible;
68 underwent ACR alone and 32 had ACR with a subacromial decompression
(ASD). ACR resulted in a highly significant improvement in the range
of movement and functional outcome, as measured by the Oxford shoulder
score and EuroQol EQ-5D index. The mean cost of a quality-adjusted
life year (QALY) for an ACR and ACR with an ASD was £2563 and £3189,
respectively. ACR is thus a cost-effective procedure that can restore relatively
normal function and health-related quality of life in most patients
with a contracture of the shoulder within six months after surgery;
and the beneficial effects are not related to the duration of the
presenting symptoms. Cite this article:
The purpose of this study was to assess the clinical
and radiological outcomes of dorsal intercarpal ligament capsulodesis
for the treatment of static scapholunate instability at a minimum
follow-up of four years. A total of 59 patients who underwent capsulodesis
for this condition were included in a retrospective analysis after
a mean of 8.25 years (4.3 to 12). A total of eight patients underwent
a salvage procedure at a mean of 2.33 years (0.67 to 7.6) and were
excluded. The mean range of extension/flexion was 88° (15° to 135°)
and of ulnar/radial deviation was 38° (0° to 75°) at final follow-up.
The mean Disabilities of the Arm Shoulder and Hand (DASH) score
and Mayo wrist scores were 28 (0 to 85) and 61 (0 to 90), respectively Capsulodesis did not maintain carpal reduction over time. Although
the consequent ongoing scapholunate instability resulted in early
arthritic degeneration, most patients had acceptable long-term function
of the wrist.
This study reports the clinical and sonographic
outcome of arthroscopic rotator cuff repair in patients aged ≥ 70 years
and aimed to determine factors associated with re-tear. A total
of 69 consecutive repairs were performed in 68 patients with a mean
age of 77 years (70 to 86). Constant-Murley scores were collected
pre-operatively and at one year post-operatively. The integrity
of the repair was assessed using ultrasound. Re-tear was detected
in 20 of 62 patients (32%) assessed with ultrasound. Age at operation We conclude that arthroscopic rotator cuff repair in patients
aged ≥ 70 years is a successful procedure. The gender and age of
the patient are important factors to consider when planning management. Cite this article:
We performed a systematic review of the literature to determine
whether earlier surgical repair of acute rotator cuff tear (ARCT)
leads to superior post-operative clinical outcomes. The MEDLINE, Embase, CINAHL, Web of Science, Cochrane Libraries,
controlled-trials.com and clinicaltrials.gov databases were searched
using the terms: ‘rotator cuff’, or ‘supraspinatus’, or ‘infraspinatus’,
or ‘teres minor’, or ‘subscapularis’ AND ‘surgery’ or ‘repair’.
This gave a total of 15 833 articles. After deletion of duplicates
and the review of abstracts and full texts by two independent assessors,
15 studies reporting time to surgery for ARCT repair were included.
Studies were grouped based on time to surgery <
3 months (group
A, seven studies), or >
3 months (group B, eight studies). Weighted
means were calculated and compared using Student’s Aims
Methods
We systematically reviewed all the evidence published
in the English language on proximal interphalangeal joint (PIPJ)
replacement, to determine its effectiveness on the function of the
hand and the associated post-operative complications. Original studies were selected if they reported clinical outcome
with a minimum of one year’s follow-up. Quality was assessed using
the Cowley systematic review criteria modified for finger-joint
replacements. Of 319 articles identified, only five were adequately
reported according to our quality criteria; there were no randomised
controlled trials. PIPJ replacements had a substantial effect size
on hand pain of -23.2 (95% confidence interval (CI) -27.3 to -19.1)
and grip strength 1.2 (95% CI -10.7 to 13.1), and a small effect
on range of movement 0.2 (95% CI -0.4 to 0.8). A dorsal approach
was most successful. Post-operative loosening occurred in 10% (95%
CI 3 to 30) of ceramic and 12.5% (95% CI 7 to 21) of pyrocarbon
replacements. Post-operative complications occurred in 27.8% (95%
CI 20 to 37). We conclude that the effectiveness of PIPJ replacement has not
been established. Small observational case studies and short-term
follow-up, together with insufficient reporting of patient data,
functional outcomes and complications, limit the value of current
evidence. We recommend that a defined core set of patients, surgical and
outcome data for this intervention be routinely and systematically
collected within the framework of a joint registry.
Surgical repair of posterosuperior rotator cuff
tears has a poorer outcome and a higher rate of failure compared
with repairs of supraspinatus tears. In this prospective cohort
study 28 consecutive patients with an irreparable posterosuperior
rotator cuff tear after failed conservative or surgical treatment
underwent teres major tendon transfer. Their mean age was 60 years
(48 to 71) and the mean follow-up was 25 months (12 to 80). The
mean active abduction improved from 79° (0° to 150°) pre-operatively
to 105° (20° to 180°) post-operatively (p = 0.011). The mean active
external rotation in 90° abduction improved from 25° (0° to 70°)
pre-operatively to 55° (0° to 90°) post-operatively (p <
0.001).
The mean Constant score improved from 43 (18 to 78) pre-operatively
to 65 (30 to 86) post-operatively (p <
0.001). The median post-operative
VAS (0 to 100) for pain decreased from 63 (0 to 96) pre-operatively to
5 (0 to 56) post-operatively (p <
0.001). In conclusion, teres major transfer effectively restores function
and relieves pain in patients with irreparable posterosuperior rotator
cuff tears and leads to an overall clinical improvement in a relatively
young and active patient group with limited treatment options. Cite this article:
The purpose of this study was to evaluate the
risk of late displacement after the treatment of distal radial fractures with
a locking volar plate, and to investigate the clinical and radiological
factors that might correlate with re-displacement. From March 2007
to October 2009, 120 of an original cohort of 132 female patients
with unstable fractures of the distal radius were treated with a
volar locking plate, and were studied over a follow-up period of
six months. In the immediate post-operative and final follow-up
radiographs, late displacement was evaluated as judged by ulnar
variance, radial inclination, and dorsal angulation. We also analysed
the correlation of a variety of clinical and radiological factors
with re-displacement. Ulnar variance was significantly overcorrected
(p <
0.001) while radial inclination and dorsal angulation were
undercorrected when compared statistically (p <
0.001) with the unaffected
side in the immediate post-operative stage. During follow-up, radial
shortening and dorsal angulation progressed statistically, but none
had a value beyond the acceptable range. Bone mineral density measured
at the proximal femur and the position of the screws in the subchondral
region, correlated with slight progressive radial shortening, which
was not clinically relevant. Volar locking plating of distal radial fractures is a reliable
form of treatment without substantial late displacement. Cite this article:
We assessed the short- to mid-term survival of
metallic press-fit radial head prostheses in patients with radial
head fractures and acute traumatic instability of the elbow. The medical records of 42 patients (16 males, 26 females) with
a mean age of 56 years (23 to 85) with acute unstable elbow injuries,
including a fracture of the radial head requiring metallic replacement
of the radial head, were reviewed retrospectively. Survival of the
prosthesis was assessed from the radiographs of 37 patients after
a mean follow-up of 50 months (12 to 107). The functional results
of 31 patients were assessed using range-of-movement, Mayo elbow
performance score (MEPS), Disabilities of the Arm, Shoulder and
Hand (DASH) score and the RAND 36-item health survey. At the most recent follow-up 25 prostheses were still well fixed,
nine had been removed because of loosening, and three remained implanted
but were loose. The mean time from implantation to loosening was
11 months (2 to 24). Radiolucent lines that developed around the
prosthesis before removal were mild in three patients, moderate
in one and severe in five. Range of movement parameters and mass
grip strength were significantly lower in the affected elbow than
in the unaffected side. The mean MEPS score was 86 (40 to 100) and
the mean DASH score was 23 (0 to 81). According to RAND-36 scores,
patients had more pain and lower physical function scores than normal population
values. Loosening of press-fit radial head prostheses is common, occurs
early, often leads to severe osteolysis of the proximal radius,
and commonly requires removal of the prosthesis.
The aim of this study was to compare a third-generation
cementing procedure for glenoid components with a new technique
for cement pressurisation. In 20 pairs of scapulae, 20 keeled and
20 pegged glenoid components were implanted using either a third-generation
cementing technique (group 1) or a new pressuriser (group 2). Cement penetration
was measured by three-dimensional (3D) analysis of micro-CT scans.
The mean 3D depth of penetration of the cement was significantly
greater in group 2 (p <
0.001). The mean thickness of the cement
mantle for keeled glenoids was 2.50 mm (2.0 to 3.3) in group 1 and
5.18 mm (4.4 to 6.1) in group 2, and for pegged glenoids it was 1.72 mm
(0.9 to 2.3) in group 1 and 5.63 mm (3.6 to 6.4) in group 2. A cement
mantle <
2 mm was detected less frequently in group 2 (p <
0.001). Using the cement pressuriser the proportion of cement mantles
<
2 mm was significantly reduced compared with the third-generation
cementing technique.
This study reports the application of a novel method for quantitatively determining differences in the mechanical properties of healthy and torn rotator cuff tissues. In order to overcome problems of stress risers at the grip-tendon interface that can obscure mechanical measurements of small tendons, we conducted our investigation using dynamic shear analysis. Rotator cuff tendon specimens were obtained from 100 patients during shoulder surgery. They included 82 differently sized tears and 18 matched controls. We subjected biopsy samples of 3 mm in diameter to oscillatory deformation under compression using dynamic shear analysis. The storage modulus (G’) was calculated as an indicator of mechanical integrity. Normal tendons had a significantly higher storage modulus than torn tendons, indicating that torn tendons are mechanically weaker than normal tendons (p = 0.003). Normal tendons had a significantly higher mean shear modulus than tendons with massive tears (p <
0.01). Dynamic shear analysis allows the determination of shear mechanical properties of small tissue specimens obtained intra-operatively that could not be studied by conventional methods of tensile testing. These methods could be employed to investigate other musculoskeletal tissues. This pilot study provides some insight into mechanisms that might contribute to the failure of repair surgery, and with future application could help direct the most appropriate treatment for specific rotator cuff tears.
Local corticosteroid infiltration is a common practice of treatment
for lateral epicondylitis. In recent studies no statistically significant
or clinically relevant results in favour of corticosteroid injections
were found. The injection of autologous blood has been reported
to be effective for both intermediate and long-term outcomes. It
is hypothesised that blood contains growth factors, which induce
the healing cascade. A total of 60 patients were included in this prospective randomised
study: 30 patients received 2 ml autologous blood drawn from contralateral
upper limb vein + 1 ml 0.5% bupivacaine, and 30 patients received
2 ml local corticosteroid + 1 ml 0.5% bupivacaine at the lateral
epicondyle. Outcome was measured using a pain score and Nirschl
staging of lateral epicondylitis. Follow-up was continued for total
of six months, with assessment at one week, four weeks, 12 weeks
and six months.Objectives
Methods
We describe a new surgical technique for the
treatment of lacerations of the extensor tendon in zone I, which involves
a tenodesis using a length of palmaris longus tendon one-quarter
of its width. After exposing the dorsal aspect of the distal interphalangeal
joint and harvesting the tendon, a 1.5 mm drill bit is passed through
the insertion of the extensor tendon into the distal phalanx where
it penetrates through the skin of the pulp of the digit. The palmaris
longus tendon is threaded through the drill hole from dorsal to
ventral and the ventral end is tied in a simple knot and trimmed.
The palmaris longus tendon is then sutured to the extensor tendon
close to its insertion, and also at the middle of the middle phalanx. The operation was undertaken on 67 patients: 27 with an acute
injury and 40 patients with a chronic mallet deformity. One finger
(or the thumb) was involved in each patient. At a mean follow-up
of 12 months (6 to 18), 66 patients (98.5%) received excellent or
good results according to both the American Society for Surgery
of the Hand (ASSH) classification and Miller’s classification. Tenodesis using palmaris longus tendon after complete division
of an extensor tendon in zone 1 is a reliable form of treatment
for isolated acute or chronic ruptures.
The pathogenesis of rotator cuff disease (RCD) is complex and
not fully understood. This systematic review set out to summarise
the histological and molecular changes that occur throughout the
spectrum of RCD. We conducted a systematic review of the scientific literature
with specific inclusion and exclusion criteria.Introduction
Methods
We compared the outcome of arthroscopic repair of the rotator cuff in 32 diabetic patients with the outcome in 32 non-diabetic patients matched for age, gender, size of tear and comorbidities. The Constant-Murley score improved from a mean of 49.2 (24 to 80) pre-operatively to 60.8 (34 to 95) post-operatively (p = 0.0006) in the diabetic patients, and from 46.4 (23 to 90) pre-operatively to 65.2 (25 to 100) post-operatively (p = 0.0003) in the non-diabetic patients at six months. This was significantly greater (p = 0.0002) in non-diabetic patients (18.8) than in diabetics (11.6). There was no significant change in the mean mental component of the Short-Form 12, but the mean physical component increased from 35 to 41 in non-diabetics (p = 0.0001), and from 37 to 39 (p = 0.15) in diabetics. These trends were observed at one year. Patients with diabetes showed improvement of pain and function following arthroscopic rotator cuff repair in the short term, but less than their non-diabetic counterparts.
The zona conoidea comprises the area of the lateral
trochlear ridge of the humerus. The purpose of this study is to reintroduce
this term ‘zona conoidea’ to the discussion of the human elbow and
to investigate its significance in the development of osteoarthritis
of the elbow. The upper extremities of 12 cadavers were prepared. With the
forearm in neutral, pronation and supination, the distance between
the bevel of the radial head and zona conoidea was inspected. A
total of 12 healthy volunteers had a CT scan. The distance between
the zona conoidea and the bevelled rim of the radial head was measured
in these positions. In the anatomical specimens, early osteo-arthritic changes were
identified in the posteromedial bevelled rim of the radial head,
and the corresponding zona conoidea in supination. Measurement in
the CT study showed that in full supination, the distance between
the bevel of the radial head and the zona conoidea was at a minimum. This study suggests that the significant contact between the
bevel of the radial head and the zona conoidea in supination is
associated with the initiation of osteoarthritis of the elbow in
this area.
Radial osteotomy is currently advocated for patients
with Lichtman’s stages II and IIIA of Kienböck’s disease; its place
in the treatment of patients with stage IIIB disease remains controversial.
The purpose of this study was to evaluate the medium-term results
of this procedure and to compare the outcome in patients with stage
IIIB disease and those with earlier stages (II and IIIA). A total
of 18 patients (18 osteotomies) were evaluated both clinically and radiologically
at a mean follow-up of 10.3 years (4 to 18). Range of movement,
grip strength and pain improved significantly in all patients; the
functional score (Nakamura Scoring System (NSSK)) was high and self-reported disability
(Disabilities of Arm, Shoulder and Hand questionnaire) was low at
the final follow-up in all patients evaluated. Patients with stage
IIIB disease, however, had a significantly lower grip strength,
lower NSSK scores and higher disability than those in less advanced
stages. Radiological progression of the disease was not noted in
either group, despite the stage. Radial osteotomy seems effective
in halting the progression of disease and improving symptoms in
stages II, IIIA and IIIB. Patients with less advanced disease should
be expected to have better clinical results.
Mason type III fractures of the radial head are treated by open reduction and internal fixation, resection or prosthetic joint replacement. When internal fixation is performed, fixation of the radial head to the shaft is difficult and implant-related complications are common. Furthermore, problems of devascularisation of the radial head can result from fixation of the plate to the radial neck. In a small retrospective study, the treatment of Mason type III fractures with fixation of the radial neck in 13 cases (group 2) was compared with 12 cases where no fixation was performed (group 1). The mean clinical and radiological follow-up was four years (1 to 9). The Broberg-Morrey index showed excellent results in both groups. Degenerative radiological changes were seen more frequently in group 2, and removal of the implant was necessary in seven of 13 cases. Post-operative evaluation of these two different techniques revealed similar ranges of movement and functional scores. We propose that anatomical reconstruction of the radial head without metalwork fixation to the neck is preferable, and the outcome is the same as that achieved with the conventional technique. In addition degenerative changes of the elbow joint may develop less frequently, and implant removal is not necessary.
We undertook this study to determine the minimum
amount of coronoid necessary to stabilise an otherwise intact elbow
joint. Regan–Morrey types II and III, plus medial and lateral oblique
coronoid fractures, collectively termed type IV fractures, were
simulated in nine fresh cadavers. An electromagnetic tracking system
defined the three-dimensional stability of the ulna relative to
the humerus. The coronoid surface area accounts for 59% of the anterior articulation.
Alteration in valgus, internal and external rotation occurred only
with a type III coronoid fracture, accounting for 68% of the coronoid
and 40% of the entire articular surface. A type II fracture removed
42% of the coronoid articulation and 25% of the entire articular
surface but was associated with valgus and external rotational changes
only when the radial head was removed, thereby removing 67% of the
articular surface. We conclude that all type III fractures, as defined here, are
unstable, even with intact ligaments and a radial head. However,
a type II deficiency is stable unless the radial head is removed.
Our study suggests that isolated medial-oblique or lateral-oblique
fractures, and even a type II fracture with intact ligaments and
a functional radial head, can be clinically stable, which is consistent
with clinical observation.
Total shoulder replacement is a successful procedure for degenerative or some inflammatory diseases of the shoulder. However, fixation of the glenoid seems to be the main weakness with a high rate of loosening. The results using all-polyethylene components have been better than those using metal-backed components. We describe our experience with 35 consecutive total shoulder replacements using a new metal-backed glenoid component with a mean follow-up of 75.4 months (48 to 154). Our implant differs from others because of its mechanism of fixation. It has a convex metal-backed bone interface and the main stabilising factor is a large hollow central peg. The patients were evaulated with standard radiographs and with the Constant Score, the Simple Shoulder Test and a visual analogue scale. All the scores improved and there was no loosening, no polyethylene-glenoid disassembly and no other implant-related complications. We conclude that a metal-backed glenoid component is a good option in total shoulder replacement with no worse results than of those using a cemented all-polyethylene prosthesis.
This study investigated the anatomical relationship between the clavicle and its adjacent vascular structures, in order to define safe zones, in terms of distance and direction, for drilling of the clavicle during osteosynthesis using a plate and screws following a fracture. We used reconstructed three-dimensional CT arteriograms of the head, neck and shoulder region. The results have enabled us to divide the clavicle into three zones based on the proximity and relationship of the vascular structures adjacent to it. The results show that at the medial end of the clavicle the subclavian vessels are situated behind it, with the vein intimately related to it. In some scans the vein was opposed to the posterior cortex of the clavicle. At the middle one-third of the clavicle the artery and vein are a mean of 17.02 mm (5.4 to 26.8) and 12.45 mm (5 to 26.1) from the clavicle, respectively, and at a mean angle of 50° (12 to 80) and 70° (38 to 100), respectively, to the horizontal. At the lateral end of the clavicle the artery and vein are at mean distances of 63.4 mm (46.8 to 96.5) and 75.67 mm (50 to 109), respectively. An appreciation of the information gathered from this study will help minimise the risk of inadvertent iatrogenic vascular injury during plating of the clavicle.
We report the use of a free vascularised iliac bone graft in the treatment of 21 patients (19 men and 2 women) with an avascular nonunion of the scaphoid in which conventional bone grafting had previously failed. The mean age of the patients was 32 years (23 to 46) and the dominant wrist was affected in 14. The mean interval from fracture to the vascularised bone grafting was 39 months (9 to 62). Pre-operative MRI showed no contrast enhancement in the proximal fragment in any patient. Fracture union was assessed radiologically or with CT scans if the radiological appearances were inconclusive. At a mean follow-up of 5.6 years (2 to 11) union was obtained in 16 patients. The remaining five patients with a persistent nonunion continued to experience pain, reduced grip strength and limited range of wrist movement. In the successfully treated patients the grip strength and range of movement did not recover to match the uninjured side. Prevention of progressive carpal collapse, the absence of donor site morbidity, good subjective results and pain relief, justifies this procedure in the treatment of recalcitrant nonunion of the scaphoid.
Fractures of the proximal humerus can lead to malalignment of the humeral head, necrosis and post-traumatic osteoarthritis. In such cases surface replacement might be a promising option. A total of 28 shoulders with glenohumeral arthritis subsequent to a fracture underwent surface replacement arthroplasty of the humeral head in patients with a mean age of 60 years (35 to 83). On the basis of the inclination of the impacted head, post-traumatic arthritis was divided into three types: type 1, an impacted fracture of the head in an anatomical position (seven cases); type 2, a valgus impacted fracture (13 cases); type 3, a varus impacted fracture (eight cases). The outcome was measured by means of the Constant score. According to the Boileau classification of the sequelae of fractures of the proximal humerus, all 28 patients had a final result of intra-capsular category 1. The mean Constant score for the 28 shoulders increased from 23.2 points (2 to 45) pre-operatively to 55.1 points (20 to 89) at a mean of 31 months (24 to 66) post-operatively. Valgus impacted fractures had significantly better results (p <
0.039). Surface replacement arthroplasty can provide good results for patients with post-traumatic osteoarthritis of the shoulder. Their use avoids post-operative complications of the humeral shaft, such as peri-prosthetic fractures. Further surgery can be undertaken more easily as the bone stock is preserved.