Wong DWC Wu DY Man HS Leung AKL

Metatarsus primus varus deformity correction is one of the main objectives in hallux valgus surgery. A ‘syndesmosis’ procedure may be used to correct hallux valgus. An osteotomy is not involved. The aim is to realign the first metatarsal using soft tissues and a cerclage wire around the necks of the first and second metatarsals.

We have retrospectively assessed 27 patients (54 feet) using the American Orthopaedic Foot and Ankle Society (AOFAS) score, radiographs and measurements of the plantar pressures after bilateral syndesmosis procedures. There were 26 women. The mean age of the patients was 46 years (18 to 70) and the mean follow-up was 26.4 months (24 to 33.4). Matched-pair comparisons of the AOFAS scores, the radiological parameters and the plantar pressure measurements were conducted pre- and post-operatively, with the mean of the left and right feet. The mean AOFAS score improved from 62.8 to 94.4 points (p < 0.001). Significant differences were found on all radiological parameters (p < 0.001). The mean hallux valgus and first intermetatarsal angles were reduced from 33.2° (24.3° to 49.8°) to 19.1° (10.1° to 45.3°) (p < 0.001) and from 15.0° (10.2° to 18.6°) to 7.2° (4.2° to 11.4°) (p < 0.001) respectively. The mean medial sesamoid position changed from 6.3(4.5 to 7) to 3.6 (2 to 7) (p < 0.001) according to the Hardy’s scale (0 to 7). The mean maximum force and the force–time integral under the hallux region were significantly increased by 71.1% (p = 0.001), (20.57 (0.08 to 58.3) to 35.20 (6.63 to 67.48)) and 73.4% (p = 0.014), (4.44 (0.00 to 22.74) to 7.70 (1.28 to 19.23)) respectively. The occurrence of the maximum force under the hallux region was delayed by 11% (p = 0.02), (87.3% stance (36.3% to 100%) to 96.8% stance (93.0% to 100%)). The force data reflected the restoration of the function of the hallux. Three patients suffered a stress fracture of the neck of the second metatarsal. The short-term results of this surgical procedure for the treatment of hallux valgus are satisfactory.

Cite this article: Bone Joint J 2014;96-B:502–7.


Bone & Joint Open
Vol. 2, Issue 3 | Pages 174 - 180
17 Mar 2021
Wu DY Lam EKF

Aims. The purpose of this study is to examine the adductus impact on the second metatarsal by the nonosteotomy nonarthrodesis syndesmosis procedure for the hallux valgus deformity correction, and how it would affect the mechanical function of the forefoot in walking. For correcting the metatarsus primus varus deformity of hallux valgus feet, the syndesmosis procedure binds first metatarsal to the second metatarsal with intermetatarsal cerclage sutures. Methods. We reviewed clinical records of a single surgical practice from its entire 2014 calendar year. In total, 71 patients (121 surgical feet) qualified for the study with a mean follow-up of 20.3 months (SD 6.2). We measured their metatarsus adductus angle with the Sgarlato’s method (SMAA), and the intermetatarsal angle (IMA) and metatarsophalangeal angle (MPA) with Hardy’s mid axial method. We also assessed their American Orthopaedic Foot & Ankle Society (AOFAS) clinical scale score, and photographic and pedobarographic images for clinical function results. Results. SMAA increased from preoperative 15.9° (SD 4.9°) to 17.2° (5.0°) (p < 0.001). IMA and MPA corrected from 14.6° (SD 3.3°) and 31.9° (SD 8.0°) to 7.2° (SD 2.2°) and 18.8° (SD 6.4°) (p < 0.001), respectively. AOFAS score improved from 66.8 (SD 12.0) to 96.1 (SD 8.0) points (p < 0.001). Overall, 98% (119/121) of feet with preoperative plantar calluses had them disappeared or noticeably subsided, and 93% (113/121) of feet demonstrated pedobarographic medialization of forefoot force in walking. We reported all complications. Conclusion. This study, for the first time, reported the previously unknown metatarsus adductus side-effect of the syndesmosis procedure. However, it did not compromise function restoration of the forefoot by evidence of our patients' plantar callus and pedobarographic findings. Level of Clinical Evidence: III. Cite this article: Bone Jt Open 2021;2(3):174–180


The Bone & Joint Journal
Vol. 103-B, Issue 1 | Pages 178 - 183
1 Jan 2021
Kubik JF Rollick NC Bear J Diamond O Nguyen JT Kleeblad LJ Wellman DS Helfet DL

Aims. Malreduction of the syndesmosis has been reported in up to 52% of patients after fixation of ankle fractures. Multiple radiological parameters are used to define malreduction; there has been limited investigation of the accuracy of these measurements in differentiating malreduction from inherent anatomical asymmetry. The purpose of this study was to identify the prevalence of positive malreduction standards within the syndesmosis of native, uninjured ankles. Methods. Three observers reviewed 213 bilateral lower limb CT scans of uninjured ankles. Multiple measurements were recorded on the axial CT 1 cm above the plafond: anterior syndesmotic distance; posterior syndesmotic distance; central syndesmotic distance; fibular rotation; and sagittal fibular translation. Previously studied malreduction standards were evaluated on bilateral CT, including differences in: anterior, central and posterior syndesmotic distance; mean syndesmotic distance; fibular rotation; sagittal translational distance; and syndesmotic area. Unilateral CT was used to compare the anterior to posterior syndesmotic distances. Results. A difference of anterior to posterior syndesmotic distance > 2 mm was observed in 89% of ankles (n = 190) on unilateral CT assessment. Using bilateral CT, we found that 35% (n = 75) of normal ankles would be considered malreduced by current malreduction parameters. In 50 patients (23%), only one parameter was anomalous, 18 patients (8%) had two positive parameters and seven patients (3%) had three. Difference in fibular rotation had the lowest false positive rate of all parameters at 6%, whereas posterior syndesmotic distance difference had the highest at 15%. Conclusion. In this study, 35% of native, uninjured syndesmoses (n = 75) would be classified as malreduced by current diagnostic standards on bilateral CT and 89% had an asymmetric incisura on unilateral CT (n = 190). Current radiological parameters are insufficient to differentiate mild inherent anatomical asymmetry from malreduction of the syndesmosis. Cite this article: Bone Joint J 2021;103-B(1):178–183


The Bone & Joint Journal
Vol. 101-B, Issue 3 | Pages 348 - 352
1 Mar 2019
Patel S Malhotra K Cullen NP Singh D Goldberg AJ Welck MJ

Aims. Cone beam CT allows cross-sectional imaging of the tibiofibular syndesmosis while the patient bears weight. This may facilitate more accurate and reliable investigation of injuries to, and reconstruction of, the syndesmosis but normal ranges of measurements are required first. The purpose of this study was to establish: 1) the normal reference measurements of the syndesmosis; 2) if side-to-side variations exist in syndesmotic anatomy; 3) if age affects syndesmotic anatomy; and 4) if the syndesmotic anatomy differs between male and female patients in weight-bearing cone beam CT views. Patients and Methods. A retrospective analysis was undertaken of 50 male and 50 female patients (200 feet) aged 18 years or more, who underwent bilateral, simultaneous imaging of their lower legs while standing in an upright, weight-bearing position in a pedCAT machine between June 2013 and July 2017. At the time of imaging, the mean age of male patients was 47.1 years (18 to 72) and the mean age of female patients was 57.8 years (18 to 83). We employed a previously described technique to obtain six lengths and one angle, as well as calculating three further measurements, to provide information on the relationship between the fibula and tibia with respect to translation and rotation. Results. The upper limit of lateral translation in un-injured patients was 5.27 mm, so values higher than this may be indicative of syndesmotic injury. Anteroposterior translation lay within the ranges 0.31 mm to 2.59 mm, and -1.48 mm to 3.44 mm, respectively. There was no difference between right and left legs. Increasing age was associated with a reduction in lateral translation. The fibulae of men were significantly more laterally translated but data were inconsistent for rotation and anteroposterior translation. Conclusion. We have established normal ranges for measurements in cross-sectional syndesmotic anatomy during weight-bearing and also established that no differences exist between right and left legs in patients without syndesmotic injury. Age and gender do, however, affect the anatomy of the syndesmosis, which should be taken into account at time of assessment. Cite this article: Bone Joint J 2019;101-B:348–352


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 8 | Pages 1069 - 1073
1 Aug 2009
Hamid N Loeffler BJ Braddy W Kellam JF Cohen BE Bosse MJ

The purpose of this study was to compare the clinical and radiological outcome of patients with intact, broken and removed syndesmosis screws after Weber B or C ankle fracture with an associated injury to the syndesmosis. We hypothesised that there would be no difference. Of a possible 142 patients who fulfilled our inclusion criteria, 52 returned for clinical and radiological assessment at least one year after surgery. Of these, 27 had intact syndesmosis screws, ten had broken screws, and 15 had undergone elective removal of the screw. The mean American Orthopaedic Foot and Ankle Society ankle/hindfoot score was 83.07 (. sd. 13.59) in the intact screw group, 92.40 (. sd. 12.69) in the broken screw group, and 85.80 (. sd. 11.33) in the removed screw group (p = 0.0466). There was no difference in clinical outcome of patients with intact or removed syndesmotic screws. Paradoxically, patients with a broken syndesmosis screw had the best clinical outcome. Our data do not support the removal of intact or broken syndesmosis screws, and we caution against attributing post-operative ankle pain to breakage of the syndesmosis screw


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 4 | Pages 405 - 410
1 Apr 2008
Dattani R Patnaik S Kantak A Srikanth B Selvan TP

The management of injury to the distal tibiofibular syndesmosis remains controversial in the treatment of ankle fractures. Operative fixation usually involves the insertion of a metallic diastasis screw. There are a variety of options for the position and characterisation of the screw, the type of cortical fixation, and whether the screw should be removed prior to weight-bearing. This paper reviews the relevant anatomy, the clinical and radiological diagnosis and the mechanism of trauma and alternative methods of treatment for injuries to the syndesmosis


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXIX | Pages 238 - 238
1 Sep 2012
Naqvi G Shafqat A Cunningham P Awan N
Full Access

Introduction. In this cohort study, the TightRope® fixation technique has been compared with the traditional screw fixation for ankle syndesmosis injuries, with respect to the accuracy of the syndesmotic reduction and their clinical correlation. Patients and Methods. This cohort study included consecutive patients treated for ankle syndesmotic diastases between July 2007 and June 2009. Single slice axial CT scans of both the ankles together were performed at the level of syndesmosis, 1 cm above the tibial plafond. More than 2 mm widening of syndesmosis as compared to normal contra-lateral ankle was considered as significant malreduction. Clinical outcomes were measured using AOFAS and FADI Scores. Results. Forty-six out of 55 eligible patients attended for the study. Twenty three patients were in the tightRope group and 23 in the syndesmosis screw group. Mean follow-up was 2.5 (1.5–3.5) years. Average age was 41.6 years in tightrope group and 39.8 years in syndesmosis screw group. The mean width of normal syndesmosis was 4.01 + 0.89 mm. In tightRope group the mean width of syndesmosis was 4.37 + 1.12 mm (t-test, p = 0.30) as compared to 5.16 + 1.92 mm in screw group (t-test, p = 0.01). Five (21.7%) out of 23 ankles in screw group had syndesmotic mal reduction, while none of the tightRope group showed mal-reduction on CT scans (fisher's exact test, p = 0.04). There was no significant difference in mean post operative AOFAS score (89.56 and 86.52) and FADI score (82.42 and 81.22) between two groups. Conclusion. The results of this study indicate that tightRope provides more accurate method of syndesmosis stabilization as compared with screw fixation. Syndesmosis malreduction is the most important independent predictor of clinical outcomes; therefore care should be taken to reduce the syndesmosis accurately


The Journal of Bone & Joint Surgery British Volume
Vol. 85-B, Issue 3 | Pages 324 - 329
1 Apr 2003
Takao M Ochi M Oae K Naito K Uchio Y

In 52 patients we compared the accuracy of standard anteroposterior (AP) radiography, mortise radiography and MRI with arthroscopy of the ankle for the diagnosis of a tear of the tibiofibular syndesmosis. In comparison with arthroscopy, the sensitivity, specificity and accuracy were 44.1%, 100% and 63.5% for standard AP radiography and 58.3%, 100% and 71.2% for mortise radiography. For MRI they were 100%, 93.1% and 96.2% for a tear of the anterior inferior tibiofibular ligament and 100%, 100% and 100% for a tear of the posterior inferior tibiofibular ligament. Standard AP and mortise radiography did not always provide a correct diagnosis. MRI was useful although there were two-false positive cases. We suggest that arthroscopy of the ankle is indispensable for the accurate diagnosis of a tear of the tibiofibular syndesmosis


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXIX | Pages 63 - 63
1 Sep 2012
Kennedy M Leong S Mitra A Dolan M
Full Access

Classical AO teaching recommends that a syndesmosis screw should be inserted at 25 to 30 degree angle to the coronal plane of the ankle. In practice accurately judging the 25/30 degree angle can be difficult, and there are several reports based on post operative CT scans demonstrating that a significant minority of patients have poorly operatively reduced syndesmotic injuries. The CT scans of 200 normal ankles in one hundred individuals which had been performed as part a CT angiogram were retrospectively examined. The centroid of the fibula and tibia in the axial plane 15mm proximal to the talar dome was calculated. Since a force vector between the centroid of the fibula and the tibia in the axial plane should not displace the fibula relative to the tibia, a line connecting the two centroids was therefore postulated to be the ideal syndesmosis line, and also the optimum position in which to place a compression clamp after reducing the syndesmosis. Where this ideal line passed through the lateral border of the fibula, and through the medial malleolus was then noted. The ideal syndesmosis line was shown to pass through the fibula with in 2mm of the lateral cortical apex of the fibula, and the anterior half of the medial malleolus in 100% of the ankles studied. The results support the concept that in the operatively reduced syndesmosis, the anterior half of the medial malleolus can be used as a reliable guide for aiming the syndesmosis drill hole, provided that the fibular entry point is at or adjacent the lateral fibular apex. The corollary of these findings is that a screw inserted through a plate on the standard antero-lateral border of the fibula, or a plate in the anti-glide position posteriorly, cannot lie in the centroidal axis of the ankle


The Bone & Joint Journal
Vol. 104-B, Issue 1 | Pages 68 - 75
1 Jan 2022
Harris NJ Nicholson G Pountos I

Aims. The ideal management of acute syndesmotic injuries in elite athletes is controversial. Among several treatment methods used to stabilize the syndesmosis and facilitate healing of the ligaments, the use of suture tape (InternalBrace) has previously been described. The purpose of this study was to analyze the functional outcome, including American Orthopaedic Foot & Ankle Society (AOFAS) scores, knee-to-wall measurements, and the time to return to play in days, of unstable syndesmotic injuries treated with the use of the InternalBrace in elite athletes. Methods. Data on a consecutive group of elite athletes who underwent isolated reconstruction of the anterior inferior tibiofibular ligament using the InternalBrace were collected prospectively. Our patient group consisted of 19 elite male athletes with a mean age of 24.5 years (17 to 52). Isolated injuries were seen in 12 patients while associated injuries were found in seven patients (fibular fracture, medial malleolus fracture, anterior talofibular ligament rupture, and posterior malleolus fracture). All patients had a minimum follow-up period of 17 months (mean 27 months (17 to 35)). Results. All patients returned to their pre-injury level of sports activities. One patient developed a delayed union of the medial malleolus. The mean return to play was 62 days (49 to 84) for isolated injuries, while the patients with concomitant injuries returned to play in a mean of 104 days (56 to 196). The AOFAS score returned to 100 postoperatively in all patients. Knee-to-wall measurements were the same as the contralateral side in 18 patients, while one patient lacked 2 cm compared to the contralateral side. Conclusion. This study suggests the use of the InternalBrace in the management of unstable syndesmotic injuries offers an alternative method of stabilization, with good short-term results, including early return to sports in elite athletes. Cite this article: Bone Joint J 2022;104-B(1):68–75


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_II | Pages 282 - 282
1 May 2010
Adib F Kazemi M Esmailijah A
Full Access

Background: Injuries to ankle joint consist 12% of visits to emergency departments. In spite of the common occurrence of ankle sprain, syndesmosis injuries are rare, but very debilitating and frequently misdiagnosed. Methods: Among 100 patients with ankle sprain we evaluated the incidence of syndesmosis sprain by MRI of the ankle. Adults who had acute ankle sprain with no fracture and examined on the same day that injury had took place were being included in the survey. Results: Out of 100 patients with ankle injury, four had syndesmosis sprain. Three patients had partial tear of syndesmotic complex and one had complete tear. All injuries occurred in sports except one which had happened in an accident, and two of the patients were athletes. Anterior inferior tibiofibular ligament was the most common ruptured ligament. Conclusions: We reported a four-percent incidence of this injury. Our high rate of this injury emphasized on the fact that all suspicious cases should go under more accurate investigation not to miss this diagnosis


The Bone & Joint Journal
Vol. 102-B, Issue 2 | Pages 212 - 219
1 Feb 2020
Ræder BW Figved W Madsen JE Frihagen F Jacobsen SB Andersen MR

Aims

In a randomized controlled trial with two-year follow-up, patients treated with suture button (SB) for acute syndesmotic injury had better outcomes than patients treated with syndesmotic screw (SS). The aim of this study was to compare clinical and radiological outcomes for these treatment groups after five years.

Methods

A total of 97 patients with acute syndesmotic injury were randomized to SS or SB. The five-year follow-up rate was 81 patients (84%). The primary outcome was the American Orthopaedic Foot and Ankle Society (AOFAS) Ankle Hindfoot Scale. Secondary outcome measures included Olerud-Molander Ankle (OMA) score, visual analogue scale (VAS), EuroQol five-dimension questionnaire (EQ-5D), range of movement, complications, reoperations, and radiological results. CT scans of both ankles were obtained after surgery, and after one, two, and five years.


Bone & Joint 360
Vol. 12, Issue 3 | Pages 8 - 9
1 Jun 2023
Stringer H


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_10 | Pages 29 - 29
1 Jun 2023
McCabe F Wade A Devane Y O'Brien C McMahon L Donnelly T Green C
Full Access

Introduction. Aneurysmal bone cysts commonly found in lower limbs are locally aggressive masses that can lead to bony erosion, instability and fractures. This has major implications in the lower limbs especially in paediatric patients, with potential growth disturbance and deformity. In this case series we describe radical aneurysmal bone cyst resection and lower limb reconstruction using cable transport and syndesmosis preservation. Materials & Methods. Case 1 - A 12-year-old boy presented with a two-week history of atraumatic right ankle pain. An X-ray demonstrated a distal tibia metaphyseal cyst confirmed on biopsy as an aneurysmal bone cyst. The cyst expanded on interval X-rays from 5.5cm to 8.5cm in 9 weeks. A wide-margin en-bloc resection was performed leaving a 13.8cm tibial defect. A cable transport hexapod frame and a proximal tibial osteotomy was performed, with syndesmosis screw fixation. The transport phase lasted 11 months. While in frame, the boy sustained a distal femur fracture from a fall. The femur and the docking site were plated at the same sitting and frame removed. At one-year post-frame removal he is pain-free, with full ankle dorsiflexion but plantarflexion limited to 25 degrees. He has begun graduated return to sport. Results. Case 2 - A 12-year-old girl was referred with a three-month history of lateral left ankle swelling. X-ray demonstrated an aneurysmal bone cyst in the distal fibula metaphysis. The cyst grew from 4.2 × 2.3cm to 5.2 × 3.32cm in 2 months. A distal fibula resection (6.2cm) with syndesmosis fixation and hexapod cable transport frame were undertaken. The frame was in situ for 13 weeks and during this time she required an additional osteotomy for premature consolidation and had one pin site infection. After 13 weeks a second syndesmosis screw was placed, frame removed, and a cast applied. 3 months later she had fibular plating, BMAC and autologous iliac crest bone graft for slow union. At 3 years post-operative she has no evidence of recurrence, is pain-free and has no functional limitation. Conclusions. We describe two cases of ankle syndesmosis preservation using cable transport for juxta-articular aneurysmal bone cysts. This allows wide resection to prevent recurrence while also preserving primary ankle stability and leg length in children. Both children had a minor complication, but both had an excellent final outcome. Cable bone transport and prophylactic syndesmosis stabilization allows treatment of challenging juxta-articular aneurysmal bone cysts about the ankle. These techniques are especially useful in large bone defects


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_7 | Pages 16 - 16
8 May 2024
Marsland D Randell M Ballard E Forster B Lutz M
Full Access

Introduction. Early clinical examination combined with MRI following a high ankle sprain allows accurate diagnosis of syndesmosis instability. However, patients often present late, and for chronic injuries clinical assessment is less reliable. Furthermore, in many centres MRI may be not be readily available. The aims of the current study were to define MRI characteristics associated with syndesmosis instability, and to determine whether MRI patterns differed according to time from injury. Methods. Retrospectively, patients with an unstable ligamentous syndesmosis injury requiring fixation were identified from the logbooks of two fellowship trained foot and ankle surgeons over a five-year period. After exclusion criteria (fibula fracture or absence of an MRI report by a consultant radiologist), 164 patients (mean age 30.7) were available. Associations between MRI characteristics and time to MRI were examined using Pearson's chi-square tests or Fisher's exact tests (significance set at p< 0.05). Results. Overall, 100% of scans detected a syndesmosis injury if performed acutely (within 6 weeks of injury), falling to 83% if performed after 12 weeks (p=0.001). In the acute group, 93.5% of patients had evidence of at least one of either PITFL injury (78.7%), posterior malleolus bone oedema (60.2%), or a posterior malleolus fracture (15.7%). In 20% of patients with a posterior malleolus bone bruise or fracture, the PITFL was reported as normal. The incidence of posterior malleolus bone bruising and fracture did not significantly differ according to time. Conclusion. For unstable ligamentous syndesmosis injuries, MRI becomes less sensitive over time. Importantly, posterior malleolus bone oedema or fracture may be the only evidence of a posterior injury. Failure to recognise instability may lead to inappropriate management of the patient, long term pain and arthritis. We therefore advocate early MRI as it becomes more difficult to ‘grade’ the injury if delayed


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_3 | Pages 11 - 11
1 Mar 2021
Wong M Wiens C Kooner S Buckley R Duffy P Korley R Martin R Sanders D Edwards B Schneider P
Full Access

Nearly one quarter of ankle fractures have a recognized syndesmosis injury. An intact syndesmosis ligament complex stabilizes the distal tibio-fibular joint while allowing small, physiologic amounts of relative motion. When injured, malreduction of the syndesmosis has been found to be the most important independent factor that contributes to inferior functional outcomes. Despite this, significant variability in surgical treatment remains. This may be due to a poor understanding of normal dynamic syndesmosis motion and the resultant impact of static and dynamic fixation on post-injury syndesmosis kinematics. As the syndesmosis is a dynamic structure, conventional CT static images do not provide a complete picture of syndesmosis position, giving potentially misleading results. Dynamic CT technology has the ability to image joints in real time, as they are moved through a range-of-motion (ROM). The aim of this study was to determine if syndesmosis position changes significantly throughout ankle range of motion, thus warranting further investigation with dynamic CT. This is an a priori planned subgroup analysis of a larger multicentre randomized clinical trial, in which patients with AO-OTA 44-C injuries were randomized to either Tightrope or screw fixation. Bilateral ankle CT scans were performed at 1 year post-injury, while patients moved from maximal dorsiflexion (DF) to maximal plantar flexion (PF). In the uninjured ankles, three measurements were taken at one cm proximal to the ankle joint line in maximal DF and maximal PF: Anterior (ASD), middle (MSD), and posterior (PSD) syndesmosis distance, in order to determine normal syndesmosis position. Paired samples t-tests compared measurements taken at maximal DF and maximal PF. Twelve patients (eight male, six female) were included, with a mean age of 44 years (±13years). The mean maximal DF achieved was 1-degree (± 7-degrees), whereas the mean maximal PF was 47-degrees (± 8-degrees). The ASD in DF was 3.0mm (± 1.1mm) versus 1.9mm (± 0.8mm) in PF (p<0.01). The MSD in DF was 3.3mm (±1.1mm) versus 2.3mm (±0.9mm) in PF (p<0.01). The PSD in DF was 5.3mm (±1.5mm) versus 4.6mm (±1.9mm) in PF (p<0.01). These values are consistent with the range of normal parameters previously reported in the literature, however this is the first study to report the ankle position at which these measurements are acquired and that there is a significant change in syndesmosis measurements based on ankle position. Normal syndesmosis position changes in uninjured ankles significantly throughout range of motion. This motion may contribute to the variation in normal anatomy previously reported and controversies surrounding quantifying anatomic reduction after injury, as the ankle position is not routinely standardized, but rather static measurements are taken at patient-selected ankle positions. Dynamic CT is a promising modality to quantify normal ankle kinematics, in order to better understand normal syndesmosis motion. This information will help optimize assessment of reduction methods and potentially improve patient outcomes. Future directions include side-to-side comparison using dynamic CT analysis in healthy volunteers


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_16 | Pages 48 - 48
17 Nov 2023
Williams D Swain L Brockett C
Full Access

Abstract. Objectives. The syndesmosis joint, located between the tibia and fibula, is critical to maintaining the stability and function of the ankle joint. Damage to the ligaments that support this joint can lead to ankle instability, chronic pain, and a range of other debilitating conditions. Understanding the kinematics of a healthy joint is critical to better quantify the effects of instability and pathology. However, measuring this movement is challenging due to the anatomical structure of the syndesmosis joint. Biplane Video Xray (BVX) combined with Magnetic Resonance Imaging (MRI) allows direct measurement of the bones but the accuracy of this technique is unknown. The primary objective is to quantify this accuracy for measuring tibia and fibula bone poses by comparing with a gold standard implanted bead method. Methods. Written informed consent was given by one participant who had five tantalum beads implanted into their distal tibia and three into their distal fibula from a previous study. Three-dimensional (3D) models of the tibia and fibula were segmented (Simpleware Scan IP, Synopsis) from an MRI scan (Magnetom 3T Prisma, Siemens). The beads were segmented from a previous CT and co-registered with the MRI bone models to calculate their positions. BVX (125 FPS, 1.25ms pulse width) was recorded whilst the participant performed level gait across a raised platform. The beads were tracked, and the bone position of the tibia and fibula were calculated at each frame (DSX Suite, C-Motion Inc.). The beads were digitally removed from the X-rays (MATLAB, MathWorks) allowing for blinded image-registration of the MRI models to the radiographs. The mean difference and standard deviation (STD) between bead-generated and image-registered bone poses were calculated for all degrees of freedom (DOF) for both bones. Results. The absolute mean tibia and fibula bone position differences (Table 1) between the bead and BVX poses were found to be less than 0.5 mm for both bones. The bone rotation differences were found to be less than 1° for all axes except for the fibula Z axis rotation which was found to be 1.46°. One study. 1. has reported the kinematics of the syndesmosis joint and reported maximum ranges of motion of 9.3°and translations of 3.3mm for the fibula. The results show that the accuracy of the methodology is sufficient to quantify these small movements. Conclusions. BVX combined with MRI can be used to accurately measure the syndesmosis joint. Future work will look at quantifying the accuracy of the talus to provide further understanding of normal ankle kinematics and to quantify the kinematics across a healthy population to act as a comparator for future patient studies. Declaration of Interest. (b) declare that there is no conflict of interest that could be perceived as prejudicing the impartiality of the research reported:I declare that there is no conflict of interest that could be perceived as prejudicing the impartiality of the research project


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_3 | Pages 56 - 56
1 Mar 2021
Schneider P Thoren J Cushnie D Del Balso C Tieszer C Sanders D
Full Access

Flexible fixation techniques combined with anatomic (open) syndesmosis reduction have demonstrated improved functional outcomes and rates of malreduction. Suture-button devices allow physiologic motion of the syndesmosis without need for implant removal, which may lower the risk of recurrent syndesmotic diastasis. There is limited longer-term assessment of the maintenance of reduction between static and flexible syndesmotic fixation using bilateral ankle CT evaluation. This is an a priori planned subgroup analysis of a multi-centre, randomized clinical trial comparing static syndesmosis fixation (two 3.5 mm screws) with flexible fixation (single knotless Tightrope) for patients with AO- OTA 44-C injuries. Patients who completed bilateral ankle CT scans at 3- and 12-month follow-up were included. The primary outcome measure was syndesmotic malreduction based on bilateral ankle CT scans, using the uninjured, contralateral ankle as a control. Anterior (ASD), middle (MSD), and posterior (PSD) syndesmosis distance were calculated to measure syndesmosis reduction. Secondary outcomes included re-operation, adverse events and functional outcomes including the EQ5D, Olerud-Molander Ankle Score (OM), Foot and Ankle Disability Index (FADI), and Work Productivity Activity Impairment Questionnaire (WPAI). Paired samples t-tests were used to compare injured to control ankles (R, v 3.5.1). 42 patients (24 Group S, 18 Group T) were included. ASD for Group T was 5.22mm (95%CI 4.69–5.77) at 3 months compared to 4.26mm (95%CI 3.82–4.71; p=0.007) in controls and 5.38mm (95%CI 4.72–6.04) at 12 months compared to 4.44mm (95%CI 3.73–5.16; p=0.048) in controls. ASD for Group S was 4.63mm (95%CI 4.17– 5.10) at 3 months compared to 4.67mm (95%CI 4.24–5.10; p=0.61) in controls, but significantly increased to 5.73mm (95%CI 4.81–6.66) at 12 months compared to 4.65mm (95%CI 4.15–5.15; p=0.04) in controls. MSD results were similar; Group T had a larger MSD than control ankles at 3 months (p=0.03) and 12 months (p=0.01), while the MSD in Group S was not different at 3 months (p=0.80) but increased at 12 months (p=<0.01). 88% (21/24) of Group S had broken or removed screws by 12 months. Unplanned re-operation was 15% in Group S and 4% in Group T (p=0.02), with an overall re-operation rate of 30% in Group S. There was no significant difference between treatment groups for EQ-5D, OM, FADI or WPAI at 3- or 12-month follow-up. Tightrope fixation resulted in greater diastasis of the ASD and MSD compared to contralateral, uninjured ankles at 3- and 12-months post-fixation. Group S initially had syndesmotic reduction similar to control ankles, but between 3- and 12-months post-fixation, there was significantly increased syndesmosis diastasis compared to controls. The majority of Group S (88%) had either broken screws or scheduled screw removal, which may explain the increased tibio-fibular diastasis seen at 12-months


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_4 | Pages 104 - 104
1 Mar 2021
Segers T De Brucker D Huysse W Van Oevelen A Pfeiffer M Burssens A Audenaert E
Full Access

Syndesmotic ankle injuries are present in one fourth of all ankle trauma and may lead to chronic syndesmotic instability as well as posttraumatic ankle osteoarthritis. The main challenge remains distinguishing them from other types of ankle trauma. Currently, the patient's injured and non-injured ankles are compared using plain radiographs to determine pathology. However, these try to quantify 3D displacement using 2D measurements techniques and it is unknown to what extent the 3D configuration of the normal ankle syndesmosis is symmetrical. We aimed to assess the 3D symmetry of the normal ankle syndesmosis between the right and left side in a non- and weightbearing CT. In this retrospective comparative cohort study, patients with a bilateral non-weightbearing CT (NWBCT; N=28; Mean age=44, SD=17.4) and weight-bearing CT (WBCT; N=33; Mean age=48 years; SD=16.3) were analyzed. Consecutive patients were included between January 2016 and December 2018 when having a bilateral non-weightbearing or weightbearing CT of the foot and ankle. Exclusion criteria were the presence of hindfoot pathology and age less than 18 years or greather than 75 years. CT images were segmented to obtain 3D models. Computer Aided Design (CAD) operations were used to fit the left ankle on top of the right ankle. The outermost point of the apex of the lateral malleolus (AML), anterior tubercle (ATF) and posterior tubercle (PTF) were computed. The difference in the coordinates attached to these anatomical landmarks of the left distal fibula in the ankle syndesmosis with respect to right were used to quantify symmetry. A Cartesian coordinate system was defined based on the tibia to obtain the direction of differences in all six degrees of freedom. Statistical analysis was performed using the Mann-Whitney U test to allow comparison between measurements from a NWBCT and WBCT. Reference values were determined for each 3D measurement in a NWBCT and WBCT based on their 2SD. The highest difference in translation could be detected in the anterior-posterior direction (Mean AP. NWBCT. = −0.01mm; 2SD=3.43/Mean AP. WBCT. =−0.1mm; 2SD=2.3) and amongst rotations in the external direction (Mean AP. NWBCT. =−0.3°; 2SD=6.7/Mean AP. WBCT. =-0,2°; 2SD=5.2). None of these differences were statistically significant in the normal ankle syndesmosis when obtained from a NWBCT compared to a WBCT (P>0.05). This study provides references values concerning the 3D symmetry of the normal ankle syndesmosis in weightbearing and non-weightbearing CT-scans. These novel data contribute relevantly to previous 2D radiographic quantifications. In clinical practice they will aid in distinguishing if a patient with a syndesmotic ankle lesion differs from normal variance in syndesmotic ankle symmetry


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_8 | Pages 129 - 129
11 Apr 2023
Vermeir R Wittouck L Peiffer M Huysse W Martinelli N Stufkens S Audenaert E Burssens A
Full Access

The incisura fibularis (IF) provides intrinsic stability to the ankle joint complex by interlocking the distal tibia and fibula. Despite a high frequency of ligamentous ankle injuries, scant attention has been given to the morphology of the IF morphology incisura fibularis in the onset and development of these lesions. Therefore, we systematically reviewed the relation between ligamentous ankle disorders and the morphometrics of the IF. A systematic literature search was conducted on following databases: PubMed, Embase and Web of Science. Search terms consisted of ‘ankle trauma’, ‘ankle injury’, ‘ankle sprain’, ‘ankle fracture’, ‘tibiofibular’, ‘fibular notch’, ‘fibular incisura’, ‘incisura fibularis’, ‘morphometric analysis’, ‘ankle syndesmosis’, ‘syndesmotic stability’. The evaluation instrument developed by Hawker et al. was used to assess the quality of the selected studies. This protocol was performed according to the PRISMA guidelines and is registered on PROSPERO (CRD42021282862). Nineteen studies were included and consisted of prospective cohort (n=1), retrospective comparative (n=10), and observational (n=8) study design. Comparative studies have found certain morphological characteristics in patients with ankle instability. Several studies (n=5) have correlated a shallow IF depth with a higher incidence of ankle injury. A significant difference has also been found concerning the incisura height and angle (n=3): a shorter incisura and more obtuse angle have been noted in patients with ankle sprains. The mean Hawker score was 28 out of 36 (range=24-31). A shallower IF is associated with ligamentous ankle lesions and might be due to a lower osseous resistance against tibiofibular displacement. However, these results should be interpreted in light of moderate methodological quality and should always be correlated with clinical findings. Further prospective studies are needed to further assess the relation between the incisura morphometrics and ligamentous disorders of the ankle joint. Keywords: ankle instability, ankle injury, incisura fibularis, fibular notch, tibiofibular morphometrics, ankle syndesmosis


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_7 | Pages 22 - 22
1 Jul 2020
Wong M Buckley R Duffy P Korley R Martin R Harrison T Sanders DW Schneider P Wiens C
Full Access

The syndesmosis ligament complex stabilizes the distal tibiofibular joint, while allowing for the subtle fibular motion that is essential for ankle congruity. Flexible fixation with anatomic syndesmosis reduction results in substantial improvements in functional outcomes. New dynamic CT technology allows real-time imaging, as the ankle moves through a range of motion. The aim of this study was to determine if dynamic CT analysis is a feasible method for evaluating syndesmosis reduction and motion following static and flexible syndesmosis fixation. This is a subgroup analysis of a larger multicenter randomized clinical trial, in which patients with AO 44-C injuries were randomized to either Tightrope (one knotless Tightrope, Group T) or screw fixation (two 3.5-mm cortical screws, Group S). Surgical techniques and rehabilitation were standardized. Bilateral ankle CT scans were performed at one year post-injury, while patients moved from maximal dorsiflexion (DF) to maximal plantar flexion (PF). Three measurements were taken at one cm proximal to the ankle joint line in maximal DF and maximal PF: anterior, midpoint, and posterior tibiofibular distances. T-tests compared Group T and Group S, and injured and uninjured ankles in each group. Fifteen patients (six Group T [three male], nine Group S [eight male]) were included. There was no difference for mean age (T = 42.8 ± 14.1 years, S = 37 ± 12.6, P = 0.4) or time between injury and CT scan (T = 13 ± 1.8 months, S = 13.2 ± 1.8, P = 0.8). Of note in Group S, seven of nine patients had at least one broken screw and one additional patient had screws removed by the time of their dynamic CT. There was no significant difference between treatment groups for tibiofibular distance measurements in maximal PF or DF. Group T showed no significant difference between the injured and uninjured side for tibiofibular measurements in maximal PF and DF, suggesting anatomic reduction. For Group S, however, there was a significantly larger distance for all three measurements at maximal PF compared to the uninjured ankle (all P < 0 .05). In all but one Group S patient, screws were broken or removed prior to their dynamic CT, allowing possible increased syndesmotic motion, similar to Group T. Despite this, dynamic CT analysis detected increased tibiofibular distance in Group S as ankles moved into maximal PF when compared with the uninjured ankle. Given the importance of anatomic syndesmosis reduction, dynamic ankle CT technology may provide valuable physiologic information warranting further investigation


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_7 | Pages 42 - 42
1 Jul 2020
Rollick N Helfet D Bear J Diamond O Wellman D
Full Access

Malreduction of the syndesmosis is a poor prognosticator following ankle fracture and has been documented in as many as 52% of patients following fracture fixation. The current standard for assessment of reduction of the syndesmosis is bilateral computed tomography (CT) scan of the ankle. Multiple radiographic parameters are utilized to define malreduction, however, there has been limited investigation into the accuracy of these measurements to differentiate malreduction from inherent anatomical asymmetry. The purpose of this study was to identify the prevalence of positive malreduction standards within the syndesmosis of native, uninjured ankles. Bilateral lower extremity CT scans including ankles were screened. Studies were excluded if the patient was skeletally immature, had pathology below the knee or if they had congenital neuromuscular syndromes. The resulting cohort consisted of 207 patients. The indication for bilateral CT scan was femoral acetabular impingement in 110 patients (53%), rotation assessment following arthroplasty in 32 patients (15%), rotation assessment following femoral fracture in 30 patients (14%), rotational assessment for patellar instability in 30 patients (14%) and five miscellaneous indications (2%). Fifty patients were reviewed by three observers independently and to determine inter-observer reliability. A single observer repeated the measurements within the same cohort four weeks later to evaluate intra-observer reliability. Three observers then measured the anterior syndesmotic distance, posterior syndesmotic distance, central syndesmotic distance, fibular rotation and sagittal fibular translation at 1cm from the distal tibial articular surface. Overall side to side variability between the left and right ankle were assessed. Previously studied malreduction standards were evaluated. These included: anterior to posterior syndesmotic distance > 2mm, central syndesmotic difference > 1.5mm, average syndesmotic distance > 2mm, fibular rotational difference > 10o and sagittal translational difference > 2mm. The inter- and intra-observer reliability was good to excellent for anterior, posterior and central syndesmotic distance, and fibular rotation measurements. Sagittal fibular translation had an ICC of 0.583, and thus was only of fair reliability. Side to side comparison revealed statistically significant difference in only anterior syndesmotic difference (p=0.038). A difference of anterior to posterior syndesmotic distance of greater than 2mm was observed in 43 patients (20.2%). Thirty eight patients (17.8%) had a central syndesmotic difference of greater than 1.5mm. A fibular rotational difference of greater than 10o was observed in 49 patients (23%). The average difference between the anterior and posterior syndesmosis was greater than 2mm in 17 patients (8.2%). Nine patients (4.2%) had sagittal translation of greater than 2mm. Eighty one patients (39%) demonstrated at least one parameter beyond previously set standards for malreduction. Only one parameters was anomalous in 54 patients (26%), 18 patients (8%) had two positive parameters, while eight patients (4%) had three. One patient was asymmetrical in all measured parameters. In this study there was no statistically significant asymmetry between ankles. However, 39% of native syndesmoses would be classified as malreduced on CT scan using previously studied malreduction limits. Current radiographic parameters are not sufficient to differentiate mild inherent anatomical asymmetry from malreduction of the syndesmosis


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_8 | Pages 84 - 84
1 Aug 2020
Kubik J Johal H Kooner S
Full Access

The optimal management of rotationally-unstable ankle fractures involving the posterior malleolus remains controversial. Standard practice involves trans-syndesmotic fixation (TSF), however, recent attention has been paid to the indirect reduction of the syndesmosis by repairing small posterior malleolar fracture avulsion fragments, if present, using open reduction internal fixation. Posterior malleolus fixation (PMF) may obviate the need for TSF. Given the limited evidence and diversity in surgical treatment options for rotationally-unstable ankle fractures with ankle syndesmosis and posterior malleolar involvement, we sought to assess the research landscape and identify knowledge gaps to address with future clinical trials. We performed a scoping review to investigate rotational ankle fractures with posterior malleolar involvement, utilizing the framework originally described by Arksey and O'Malley. We searched the English language literature using the Ovid Medline and Embase databases. All study types investigating rotationally-unstable ankle fractures with posterior malleolus involvement were categorized into defined themes and descriptive statistics were used to summarize methods and results of each study. A total of 279 articles published from 1988 to 2018 were reviewed, and 70 articles were included in the final analysis. The literature consists of studies examining the surgical treatment strategies for PMF (n=21 studies, 30%), prognosis of rotational ankle fractures with posterior malleolar involvement (n=16 studies, 23%), biomechanics and fracture pattern of these injuries (n=13 studies, 19%), surgical approach and pertinent anatomy for fixation of posterior malleolus fractures (n=12 studies, 17%), and lastly surgical treatment of syndesmotic injuries with PMF compared to TSF (n=4 studies, 6%). Uncontrolled case series of single treatment made up the majority of all clinical studies (n=44 studies, 63%), whereas controlled study designs were the next most common (n=16 studies, 23%). Majority of research in this field has been conducted in the past eight years (n=52 studies, 74%). Despite increasing concern and debate among the global orthopaedic community regarding rotationally-unstable ankle fractures with syndesmosis and posterior malleolar involvement, and an increasing trend towards PMF, optimal treatment remains unclear when comparing TSF to PMF. Current research priorities are to (1) define the specific injury pattern for which PMF adequately stabilizes the syndesmosis, and (2) conduct a randomized clinical trial comparing PMF to TSF with the assistance of the orthopaedic community at large with well-defined clinical outcomes


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_21 | Pages 10 - 10
1 Dec 2017
Boyd R Bintcliffe F
Full Access

Introduction. Injury to the syndesmosis is not always clearly demonstrated on radiographs and different tests have been described to assess for injury. In the presence of a significant injury to the syndesmosis, surgical fixation is often indicated and various fixation methods have been described. If the result of surgery is any mal-reduction of the fibula, this may result in ongoing ankle pain. Assessing how well the fibula has been reduced intra-operatively is currently limited to image intensifier views. We have previously developed a simple assessment, which has been shown to give accurate intra-operative demonstration of an injury to the syndesmosis. Our objective was to ascertain if the same test could demonstrate any malreduction of the fibular after repair of a syndesmosis injury. Methods. Seven fresh frozen cadavers had complete sydesmosis disruption performed before fixation using a well-recognised technique with a single 3.5 mm small fragment screw. Purposeful malreduction was performed in three ankles and standard reduction in the remaining four. 2–5mls of contrast medium was then injected into the ankle joint. Results. When there had been a malreduction, an obvious ‘blush’ of dye leaked superiorly into the surrounding soft tissues, whereas a normal ankle arthrogram was shown when the fibular had been anatomically reduced into the incisura and well fixed. Conclusion. This cadaveric study showed the test to be an easy and reliable adjuct to assess for acute malreduction of a syndesmosis injury


The Bone & Joint Journal
Vol. 98-B, Issue 6 | Pages 812 - 817
1 Jun 2016
Verhage SM Boot F Schipper IB Hoogendoorn JM

Aims. Involvement of the posterior malleolus in fractures of the ankle probably adversely affects the functional outcome and may be associated with the development of post-traumatic osteoarthritis. Anatomical reduction is a predictor of a successful outcome. The purpose of this study was to describe the technique and short-term outcome of patients with trimalleolar fractures, who were treated surgically using a posterolateral approach in our hospital between 2010 and 2014. Patients and Methods. The study involved 52 patients. Their mean age was 49 years (22 to 79). There were 41 (79%) AO 44B-type and 11 (21%) 44C-type fractures. The mean size of the posterior fragment was 27% (10% to 52%) of the tibiotalar joint surface. Results. Reduction was anatomical in all patients with a residual step in the articular surface of ≤ 1 mm. In nine of the C-type fractures (82%), the syndesmosis was stable after fixation of the posterior fragment and a syndesmosis screw was not required. Apart from one superficial wound infection, there were no wound healing problems. At a mean radiological follow-up of 34 weeks (seven to 131), one patient with a 44C-type fracture had widening of the syndesmosis which required further surgery. Conclusion. We conclude that the posterolateral surgical approach to the ankle gives adequate access to the posterior malleolus, allowing its anatomical reduction and stable fixation: it has few complications. Take home message: Fixation of the posterior malleolus in trimalleolar fractures can be easily done via the posterolateral approach whereby anatomical reduction and stable fixation can be reached due to adequate visualisation of the fracture. Cite this article: Bone Joint J 2016;98-B:812–17


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_1 | Pages 61 - 61
1 Jan 2017
Gueorguiev B Hagen J Klos K Lenz M Richards R Simons P
Full Access

Injury to the syndesmosis occurs in 10–13% of all operative ankle fractures and there is evidence that both incomplete treatment and malreduction of the syndesmosis can lead to poor clinical outcomes. Much attention has been given to post–operative malreduction documented by computer tomography (CT), however, there is limited data about the intact positioning and relative motion of the native syndesmosis. The aim of this study is to elucidate more detailed information on the position of the fibula in the syndesmosis during simulated weight–bearing in intact state, with sequential ligament sectioning and following two reconstructive techniques. Fourteen paired, fresh–frozen human cadaveric limbs were mounted in a weight–bearing simulation jig. CT scans were obtained under simulated foot–flat loading (75 N) and in single–legged stance (700 N), in five foot positions: neutral, 15° external rotation, 15° internal rotation, 20° dorsiflexion, and 20° plantarflexion. The elements of the syndesmosis and the deltoid ligament were sequentially sectioned. One limb of each pair was then reconstructed via one of two methods: Achilles autograft and peroneus longus ligamentoplasty. The specimens were rescanned in all 5 foot positions following each ligament resection and reconstruction. Measurements of fibular diastasis, rotation and anterior–posterior translation were performed on the axial cuts of the CT scans, 1 cm proximal to the roof of the plafond. Multiple measurements were made to define the position of the fibula in the incisura. Clinically relevant deformity patterns were produced. The deformity at the incisura was consistent with clinical injury, and the degree of displacement in all ligament states was dependent on the foot position. The most destructive state resulted in the most deformity at the syndesmosis. Differences between the intact and reconstructed states were found with all measurements, especially when the foot was in external rotation and dorsiflexion. There was no significant difference with direct comparison of the reconstructions. This study has detailed the motion of the fibula in the incisura and its variation with foot position. Neither reconstruction was clearly superior and both techniques had difficulty in the externally rotated and dorsiflexed foot positions. This study design can serve as a model for future ex–vivo testing of reconstructive techniques


Orthopaedic Proceedings
Vol. 97-B, Issue SUPP_14 | Pages 10 - 10
1 Dec 2015
Calder J Bamford R McCollum G
Full Access

This study investigated athletes presenting with grade II syndesmosis injuries and identified the clinical and radiological factors important in differentiating a stable from dynamically unstable injury and those findings associated with a longer recovery and return to sport. Sixty-four athletes were prospectively assessed with an average follow-up of 37 months (range 24–66 months). Athletes with an isolated distal syndesmosis (+/− medial deltoid ligament) injury were included. Those athletes with a concomitant ankle fracture were excluded. Those considered stable (grade IIa) were treated conservatively with a boot and progressive rehabilitation. Those with clinical signs of instability underwent arthroscopy and if instability was confirmed (grade IIb) the syndesmosis was stabilized surgically. The clinical assessment of injury to individual ligaments of the ankle and syndesmosis were recorded along with MRI findings, complications and time to return to play. All athletes returned to the same level of professional sport – 28 with IIa injuries returned at a mean of 45 days whereas the 36 with grade IIb injuries returned to play at a mean of 64 days (p< 0.001). Clinical assessment of injury to the ligaments of the syndesmosis correlated well with MRI findings. Those with a positive squeeze test were 9.5 times as likely and those with a deltoid injury 11 times more likely to have an unstable syndesmosis confirmed arthroscopically. The combination of injury to the AITFL and deltoid ligament was associated with a delay in return to sport. Concomitant injury to the ATFL indicated a different mechanism of injury with the syndesmosis less likely to be unstable and was associated with an earlier return to sport. Clinical and MRI findings may differentiate stable from dynamically unstable grade II injuries and identify which athletes may benefit from early arthroscopic assessment and stabilization. It also suggests the timeframe for expected return to play


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_7 | Pages 23 - 23
8 May 2024
Jayatilaka M Fisher A Fisher L Molloy A Mason L
Full Access

Introduction. The treatment of posterior malleolar fractures is developing. Mason and Molloy (Foot Ankle Int. 2017 Nov;38(11):1229-1235) identified only 49% of posterior malleolar rotational pilon type fractures had syndesmotic instabilities. This was against general thinking that fixation of such a fragment would stabilize the syndesmosis. Methods. We examined 10 cadaveric lower limbs that had been preserved for dissection at the Human Anatomy and Resource Centre at Liverpool University in a solution of formaldehyde. The lower limbs were carefully dissected to identify the ligamentous structures on the posterior aspect of the ankle. To compare the size to the rotational pilon posterior malleolar fracture (Mason and Molloy 2A and B) we gathered information from our posterior malleolar fracture database. 3D CT imaging was analysed using our department PACS system. Results. The PITFL insertion on the posterior aspect of the tibia is very large. The average size of insertion was 54.9×47.1mm across the posterior aspect of the tibia. Medially the PITFL blends into the sheath of tibialis posterior and laterally into the peroneal tendon sheath. 78 posterior lateral and 35 posterior medial fragments were measured. On average, the lateral to medial size of the posteromalleolar fragment was 24.5mm in the posterolateral fragment, and 43mm if there is a posteromedial fragment present also. The average distal to proximal size of the posterolateral fragment was 24.5mm and 18.5mm for the posteromedial fragment. Conclusion. The PITFL insertion on the tibia is broad. In comparison to the average size of the posterior malleolar fragments, the PITFL insertion is significantly bigger. Therefore, for a posterior malleolar fracture to cause posterior syndesmotic instability, a ligamentous injury will also have to occur. This explains the finding by Mason and Molloy that only 49% of type 2 injuries had a syndesmotic injury on testing


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_9 | Pages 5 - 5
16 May 2024
Chong H Banda N Hau M Rai P Mangwani J
Full Access

Introduction. Ankle fractures represent approximately 10% of the fracture workload and are projected to increase due to ageing population. We present our 5 years outcome review post-surgical management of ankle fractures in a large UK Trauma unit. Methods. A total of 111 consecutive patients treated for an unstable ankle fracture were entered into a database and prospectively followed up. Baseline patient characteristics, complications, further intervention including additional surgery, functional status were recorded during five-year follow-up. Pre-injury and post-fixation functional outcome measures at 2-years were assessed using Olerud-Molander Ankle Scores (OMAS) and Lower Extremity Functional Scales (LEFS). A p value < 0.05 was considered significant. Results. The mean age was 46 with a male:female ratio of 1:1.1. The distribution of comorbidities was BMI >30 (25%), diabetes (5%), alcohol consumption >20U/week (15%) and smoking (26%). Higher BMI was predictive of worse post-op LEFS score (p = 0.02). Between pre-injury and post fixation functional scores at 2 years, there was a mean reduction of 26.8 (OMAS) and 20.5(LEFS). Using very strict radiological criteria, 31 (28%) had less than anatomical reduction of fracture fragments intra-operatively. This was, however, not predictive of patients' functional outcome in this cohort. Within 5-year period, 22 (20%) patients had removal of metalwork from their ankle, with majority 13 (59%) requiring syndesmotic screw removal. Further interventions included: joint injection (3), deltoid reconstruction (1), arthroscopic debridement (1), superficial sinus excision (2), and conversion to hindfoot nail due to failure of fixation (1). Reduction in OMAS was predictive of patients' ongoing symptoms (p=0.01). Conclusion. There is a significant reduction in functional outcome after ankle fracture fixation and patients should be counselled appropriately. Need for removal of metalwork is higher in patients who require syndesmosis stabilisation with screw(s)


Bone & Joint Research
Vol. 9, Issue 6 | Pages 258 - 267
1 Jun 2020
Yao X Zhou K Lv B Wang L Xie J Fu X Yuan J Zhang Y

Aims. Tibial plateau fractures (TPFs) are complex injuries around the knee caused by high- or low-energy trauma. In the present study, we aimed to define the distribution and frequency of TPF lines using a 3D mapping technique and analyze the rationalization of divisions employed by frequently used classifications. Methods. In total, 759 adult patients with 766 affected knees were retrospectively reviewed. The TPF fragments on CT were multiplanar reconstructed, and virtually reduced to match a 3D model of the proximal tibia. 3D heat mapping was subsequently created by graphically superimposing all fracture lines onto a tibia template. Results. The cohort included 405 (53.4%) cases with left knee injuries, 347 (45.7%) cases with right knee injuries, and seven (0.9%) cases with bilateral injuries. On mapping, the hot zones of the fracture lines were mainly concentrated around the anterior cruciate ligament insertion, posterior cruciate ligament insertion, and the inner part of the lateral condyle that extended to the junctional zone between Gerdy’s tubercle and the tibial tubercle. Moreover, the cold zones were scattered in the posteromedial fragment, superior tibiofibular syndesmosis, Gerdy’s tubercle, and tibial tubercle. TPFs with different Orthopaedic Trauma Association/AO Foundation (OTA/AO) subtypes showed peculiar characteristics. Conclusion. TPFs occurred more frequently in the lateral and intermedial column than in the medial column. Fracture lines of tibial plateau occur frequently in the transition zone with marked changes in cortical thickness. According to 3D mapping, the four-column and nine-segment classification had a high degree of matching as compared to the frequently used classifications. Cite this article: Bone Joint Res 2020;9(6):258–267


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_2 | Pages 1 - 1
1 Jan 2014
Wong F Mushtaq N Jones I Singh S Abbasian A
Full Access

Introduction:. Recent published studies have examined the normal dimensions of the syndesmosis on CT. However, previous anatomical studies have shown variations of the articulating facets within the tibialae fibularis and may contribute to the false appearance of increased spacing within the syndesmosis. In this study, we measured and compared anterior and posterior distances of the distal tibiofibular(DTF) syndesmosis on MRI and CT imaging. Methods:. We identified adult patients who had had both a CT scan and an MRI scan of their ipsilateral ankle to investigate symptoms unrelated to the DTF syndesmosis. The anterior and the posterior DTF dimensions were measured on CT and MRI axial images, at the level of the distal tibial physeal scar. This was taken from anterior tubercle of tibia and from the most anterior aspect of the posterior tibial tubercle to the nearest point of medial aspect of the fibula. The geometrical shapes of the syndesmosis and the anterior tibial tubercle were also recorded. Results:. 16 ankles in 15 patients were included. The mean age was 34.6+/−8.8 years. The mean (SD) for the anterior DTF distance was 2.0 mm (0.7 mm) on MRI and 2.9 mm (0.9 mm) on CT whilst the mean posterior DTF distance was 3.2 mm (1.1 mm) on MRI and 4.3 mm (1.0 mm) on CT. This difference reached statistical significance (p < 0.001, paired T-test). When examining the shape of the syndesmosis on MRI, 56% were crescent and 44% rectangular, this was compared to 69% and 31%, respectively, on CT. There was, however, no statistical difference in the shape of the syndesmosis between the two radiological modalities (p=0.625, McNemar test). Conclusion:. CT appears to over-estimate the distal tibiofibular separation and may lead to a false positive diagnosis. Further studies are needed to establish the reliability in the use of CT scans to investigate normal and abnormal syndesmosis


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_12 | Pages 20 - 20
1 Mar 2013
Ghaffar A Hickey B Rice R Davies H
Full Access

Approximately 20% of patients with ankle fracture sustain syndesmosis injury. This is most common in trans-syndesmotic (type B) and supra-syndesmotic (type C) fibula fractures. Intra-operative assessment of syndesmosis integrity is important because failure to treat these injuries can result in ankle instability and pain. Our aim was to audit the documentation of intra-operative testing of syndesmosis during ankle fracture open reduction and internal fixation (ORIF). All patients who had ankle fracture ORIF between 1/1/2010 and 21/11/2011 were included. Pre-operative radiographs were reviewed and fractures were classified according to AO classification. Operation notes were reviewed for documentation of assessment of syndesmosis integrity. 153 patients, of mean age 50 years (15–93) were included. 60% (n=92) were female. In 78% of cases (n=119), an assessment of syndesmosis integrity was documented in the operation note. Of the patients with no documented syndesmosis assessment (n=35), the majority had type B fractures (n=34). One patient had a type C fracture. We have shown that 22% of patients undergoing ankle ORIF for fracture do not have documented assessment of syndesmosis integrity. We suggest that all patients who have ankle ORIF should have intra-operative assessment and documentation of syndesmosis integrity so these injuries are identified and treated accordingly


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_8 | Pages 50 - 50
11 Apr 2023
Souleiman F Zderic I Pastor T Gehweiler D Gueorguiev B Galie J Kent T Tomlinson M Schepers T Swords M
Full Access

The quest for optimal treatment of acute distal tibiofibular syndesmotic disruptions is still in progress. Using suture-button repair devices is one of the dynamic stabilization options, however, they may not be always appropriate for stabilization of length-unstable syndesmotic injuries. Recently, a novel screw-suture repair system was developed to address such issues. The aim of this study was to investigate the performance of the novel screw-suture repair system in comparison to a suture-button stabilization of unstable syndesmotic injuries. Eight pairs of human cadaveric lower legs were CT scanned under 700 N single-leg axial loading in five foot positions – neutral, 15° external/internal rotation and 20° dorsi-/plantarflexion – in 3 different states: (1) pre-injured (intact); (2) injured, characterized by complete syndesmosis and deltoid ligaments cuts simulating pronation-eversion injury types III and IV as well as supination-eversion injury type IV according to Lauge-Hansen; (3) reconstructed, using a screw-suture (FIBULINK, Group 1) or a suture-button (TightRope, Group 2) implants for syndesmotic stabilization, placed 20 mm proximal to the tibia plafond. Following, all specimens were: (1) biomechanically tested over 5000 cycles under combined 1400 N axial and ±15° torsional loading; (2) rescanned. Clear space (diastasis), anterior tibiofibular distance, talar dome angle and fibular shortening were measured radiologically from CT scans. Anteroposterior (AP), axial, mediolateral and torsional movements at the distal tibiofibular joint level were evaluated biomechanically via motion tracking. In each group clear space increased significantly after injury (p ≤ 0.004) and became significantly smaller in reconstructed compared with both pre-injured and injured states (p ≤ 0.041). In addition, after reconstruction it was significantly smaller in Group 1 compared to Group 2 (p < 0.001). AP and axial movements were significantly smaller in Group 1 compared with Group 2 (p < 0.001). No further significant differences were identified/detected between the groups (p ≥ 0.113). Although both implant systems demonstrate ability for stabilization of unstable syndesmotic injuries, the screw-suture reconstruction provides better anteroposterior translation and axial stability of the tibiofibular joint and maintains it over time under dynamic loading. Therefore, it could be considered as a valid option for treatment of syndesmotic disruptions


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_7 | Pages 22 - 22
4 Apr 2023
Souleiman F Zderic I Pastor T Gehweiler D Gueorguiev B Galie J Kent T Tomlinson M Schepers T Swords M
Full Access

The quest for optimal treatment of acute distal tibiofibular syndesmotic disruptions is still in full progress. Using suture-button repair devices is one of the dynamic stabilization options, however, they may not be always appropriate for stabilization of length-unstable syndesmotic injuries. Recently, a novel screw-suture repair system was developed to address such issues. The aim of this study was to investigate the performance of the novel screw-suture repair system in comparison to a suture-button stabilization of unstable syndesmotic injuries. Eight pairs of human cadaveric lower legs were CT scanned under 700 N single-leg axial loading in five foot positions – neutral, 15° external/internal rotation and 20° dorsi-/plantarflexion – in 3 different states: (1) pre-injured (intact); (2) injured, characterized by complete syndesmosis and deltoid ligaments cuts simulating pronation-eversion injury types III and IV, and supination-eversion injury type IV according to Lauge-Hansen; (3) reconstructed, using a screw-suture (FIBULINK, Group 1) or a suture-button (TightRope, Group 2) implants for syndesmotic stabilization, placed 20 mm proximal to the tibia plafond/joint surface. Following, all specimens were: (1) biomechanically tested over 5000 cycles under combined 1400 N axial and ±15° torsional loading; (2) rescanned. Clear space (diastasis), anterior tibiofibular distance, talar dome angle and fibular shortening were measured radiologically from CT scans. Anteroposterior, axial, mediolateral and torsional movements at the distal tibiofibular joint level were evaluated biomechanically via motion tracking. In each group clear space increased significantly after injury (p ≤ 0.004) and became significantly smaller in reconstructed compared with both pre-injured and injured states (p ≤ 0.041). In addition, after reconstruction it was significantly smaller in Group 1 compared to Group 2 (p < 0.001). Anteroposterior and axial movements were significantly smaller in Group 1 compared with Group 2 (p < 0.001). No further significant differences were detected between the groups (p ≥ 0.113). Conclusions. Although both implant systems demonstrate ability for stabilization of unstable syndesmotic injuries, the screw-suture reconstruction provides better anteroposterior translation and axial stability of the tibiofibular joint and maintains it over time under dynamic loading. Therefore, it could be considered as a valid option for treatment of syndesmotic disruptions


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXII | Pages 70 - 70
1 May 2012
Craik J Rajagopalan S Lloyd J Sangar A Taylor H
Full Access

Introduction. Syndesmosis injuries are significant injuries and require anatomical reduction. However, stabilisation of these injuries with syndesmosis screws carries specific complications and many surgeons advocate a second operation to remove the screw. Primary Tightrope suture fixation has been shown to be an effective treatment for syndesmotic injuries and avoids the need for a second operation. Materials and Methods. A retrospective audit identified patients who were treated for syndesmosis injuries over a two year period. Theatre and clinic costs were obtained to compare the cost of syndesmosis fixation using diastasis screws with the estimated cost of primary syndesmosis fixation using a Tightrope suture. Results. 79 patients received diastasis screw fixation of syndesmosis injuries between January 2007 and January 2009. The mean number of follow up clinic appointments was 3.7 following initial surgery, and 2.2 following diastasis screw removal. Allowing for device, theatre time and clinic appointment costs, and an estimated average of 4 follow up appointments following Tightrope syndesmosis fixation, primary fixation with this device could a saving of 34 theatre slots, 68 outpatient clinic appointments, and £12,138 per year at our hospital. Discussion. Biomechanical studies have demonstrated a reduction in normal tibiotalar external rotation with the presence of a diastasis screw, and there are several published reports of complications when these screws are retained. The Tightrope suture provides reduction of the syndesmosis whilst allowing normal physiological movement at the distal tibiofibular joint and negates the need for a second operation to remove the implant. In addition there may be improvements in foot and ankle scores and a faster return to work when these devices are used compared with traditional screw fixation. Conclusion. In addition to the patient benefits, our audit suggests that there may be significant financial benefits associated with primary syndesmosis fixation with Tightrope sutures


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 473 - 473
1 Sep 2012
Kotwal R Rath N Paringe V Lyons K Thomas R
Full Access

Introduction. The assessment of the accuracy of reduction of the ankle syndesmosis has traditionally been made using plain radiographic measurements. Recent studies have shown that computerized tomography (CT) scan is more sensitive than radiographs in detecting diastasis. The ethos has now therefore shifted towards CT scan assessment of the syndesmosis. There is however no validated method to scan the syndesmosis and measure it on the CT scans. This exposes the patient to significant radiation risk and also to anxiety from inappropriate interpretation from these scans. The objectives of this research project are to investigate the current practice of CT scanning the syndesmosis at a University Hospital and to devise a new CT protocol to reduce radiation exposure to patients and to assist surgeons in interpreting the observations. Methods. Research Ethics Committee approval was obtained. Current practice was evaluated. A new 5 cut CT protocol was devised. Starting at the level of the distal tibial plafond, 5 cuts were made proximally 0.5 cm apart. Accuracy of the syndesmosis reduction was assessed just above the distal tibial plafond. Both the injured and the normal sides were scanned 12 weeks post surgery. The normal side served as a control. Results. Current practice revealed that patients had on an average 620 cuts CT scan with radiation exposure of 0.2 mSv. 25 patients were prospectively recruited for the new 5 cut CT protocol. The radiation exposure with the new protocol was only 0.002 mSv. Comparison with the normal side revealed that 5 (20%) of syndesmosis had residual diastasis. The only difficulty with the new protocol was getting both the ankle joint lines at the same level for the first CT cut. Discussion and Conclusion. Our CT scan protocol has insignificant radiation risk, even lower than a single chest radiograph. Comparing the measurements between the fractured and the normal sides provides an accurate assessment of the reduction of the syndesmosis. Significance of the measurements on the CT scan will be correlated with functional scores


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_II | Pages 56 - 56
1 Feb 2012
McCartan D Thornes B Borton D
Full Access

We report on the first clinical cases of the Arthrex Ankle Syndesmosis TightRope (winner of 2003 BOA Technological Achievement Award and 2004 Cutlers' Prize), which has recently been licensed for use where classically a syndesmosis screw would be used. Twelve patients with Weber C ankle fractures treated with Arthrex TightRope syndesmosis fixation have a minimum of six months follow-up. The syndesmosis was fixed with the ankle in plantarflexion to aid reduction. Patient demographics, including fracture classification and mode of injury were obtained. Parameters measured at follow-up included ankle range of motion, maintenance of reduction and fibular length, and AOFAS ankle outcome score. The patient cohort showed a typical bimodal distribution of age. Age over 65 years was associated with a poorer outcome. Five patients had ankle fracture-dislocations, which was a factor for a poorer outcome. Nine patients had fibular plate fixation in addition to syndesmosis fixation, whilst three patients with Maisonneuve injuries had syndesmosis fixation only. There were no major complications, loss of reduction, wound problems, implant loosening or osteolysis. Ankle dorsiflexion was not restricted and mean total ankle range of motion was comparable to the uninjured side. No patient required secondary surgery for any reason, including hardware removal. Arthrex TightRope fixation is a simple, safe and effective method of ankle syndesmosis fixation, which allows physiological micromotion. Fixation in plantarflexion provides optimum syndesmosis compression for reduction, and does not compromise ankle range of motion. The Arthrex Ankle Syndesmosis TightRope may become the treatment of choice in Weber C ankle fractures


Orthopaedic Proceedings
Vol. 90-B, Issue SUPP_I | Pages 48 - 48
1 Mar 2008
Jenkinson R Sanders D MacLeod M Domonkos A
Full Access

This study is designed to evaluate intra-operative stress testing on detection of syndesmosis injuries. We evaluated forty patients with ankle fractures requiring surgery. Their ankles were subjected to stress examinations after each stage of fixation. These were compared to the contralateral side. Biomechanical criteria were used to predict need for syndesmosis fixation. In 42% of the fractures, intra-operative fluoroscopy found an unpredicted syndesmosis injury. In 8% the syndesmosis was intact despite prediction. Medial malleolar fixation was not adequate for syndesmosis fixation as shown by stress testing. These findings may have implications for future diagnosis and treatment of syndesmosis injuries. This study is designed to evaluate the utility of intra-operative fluoroscopic stress testing in diagnosing tibio-fibular syndesmotic injuries. Forty skeletally mature patients with unilateral external rotation ankle fractures requiring open reduction and internal fixation were prospectively recruited. Intra-operatively the injured ankle was examined fluoroscopically using external rotation, valgus and anterior drawer stress tests, as well as static antero-posterior, mortise, and lateral ankle views. Stress testing was performed using a standardized force of 37.5 N. Stress testing was done after each stage of fixation (lateral, medial, and syndesmotic). The uninjured contralateral limb was examined as a control, and a 1 mm side to side difference was defined as a positive stress examination. Intra-operative fluoroscopy detected unpredicted syndesmotic injuries in 42 % of ankle injuries. In all cases, fixation of the medial malleolus did not restore syndesmotic stability. In 8 % of ankle injuries, a syndesmotic injury was predicted but stress testing revealed the syndesmosis intact. Intra-operative fluoroscopy is a more sensitive modality for detection of otherwise unpredicted syndesmotic injuries compared to criteria based upon static radiographs. Medial malleolar fixation did not add stability to syndesmotic injuries in this study. Injuries involving the distal tibio-fibular syndesmosis are difficult to detect. Previously, the decision to stabilize the syndesmosis in ankle fractures was based upon biomechanical criteria and static radiography. This and other recent studies challenge this, suggesting fluoroscopic stress testing is a better diagnostic method for these poorly tolerated injuries. Funding: Synthes Canada, Smith Nephew Richards Inc


Orthopaedic Proceedings
Vol. 91-B, Issue SUPP_II | Pages 240 - 240
1 May 2009
Manjoo A Sanders D Tieszer C
Full Access

Screw fixation of the injured syndesmosis restores stability, but may reduce ankle motion. We wished to determine whether functional and radiographic results are improved by removal of syndesmosis screws. In addition, we studied whether large fragment screws have an advantage compared to small fragment screws. We hypothesised that retained intact syndesmosis screws are detrimental to ankle function. One hundred and seven adults with ankle fractures requiring syndesmosis screw fixation between 2001 and 2005 were retrospectively studied. Indications for syndesmosis fixation were a positive intraoperative external rotation stress test or inadequate lateral column buttress. Weight bearing was encouraged six weeks postoperatively. Syndesmosis screws were only removed for tenderness, prominence or ankle dorsiflexion < 0.05. The LEM score for patients with intact screws was 70 ± 26 compared with 85 ± 20 for broken, loosened or removed screws (p=0.05). The OM score for patients with intact screws was 48 ± 36 compared with 63 ± 27 for broken, loosened or removed screws (p=0.12). There was no difference in outcome comparing broken, loosened, and removed screws. The tibiofibular clear space for intact screws was 3.3 ± 1.3 compared with 4.1 ± 1.7 for removed, broken or loosened screws (p=0.02). There was no difference in outcome comparing large and small fragment screws. Patients with broken, loosened or removed syndesmosis screws have better functional outcome compared to intact screws. The syndesmosis allows fibular rotation, shortening and translation during gait; the presence of an intact syndesmosis screw may restrict this motion. There was no disadvantage to leaving broken or loosened screws in-situ


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_II | Pages 122 - 123
1 May 2011
Grice J Briant-evans T Dala-ali B Haleem S Hodkinson S Jowett A
Full Access

Introduction: Ankle diastasis injury occurs in up to 20% of ankle fractures. Various techniques have been used to treat syndesmosis injuries, but controversy remains and outcome is variable. In light of some recent cases of substandard syndesmosis fixations requiring revision, an audit of our results was undertaken. Method: Study type: Retrospective audit of radiographs and patient records. Data collection: patients were selected using an orthopaedic database search for operations coded as distal tib/fib ORIF or ankle ORIF. Study period: 12 months, July 2008 to July 2009 (currently data has been analyzed on the first 6 months only, the remaining 6 months will follow). Audit questions to be answered: How is ankle diastasis injury being managed? Are we reducing syndesmosis correctly? Should there be a revision to local policy?. Audit standard: Syndesmoses should be adequately reduced and fixation techniques employed should be in accordance with recommendations in standard Orthopaedic reference texts (Rockwood & Green, AO fixation manual 3). Results: 76 ankle ORIFs in July to December 2008 inclusive. Out of these, 16 had diastasis fixation (21%). 2 of the patients had a syndesmosis width over 6 mm indicating an inadequate reduction of the syndesmosis 1. Both of these required revision surgery. In total 70% of the post operative x-rays showed inadequate syndesmosis fixation or reduction. Discussion: The single most predictive indicator of a favourable function is accurate reduction of the syndesmosis 2. Substandard fixations are associated with poor long term outcomes. This raises the potential for litigation and the requirement for education and policy change. We have produced policy guidelines for theatre and circulated the information to all surgeons. A further audit will be carried out to assess the effectiveness of this in 6 months time. (The data will be available from this re-audit for presentation at the conference.)


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXII | Pages 43 - 43
1 May 2012
Kotwal R Paringe V Rath N Lyons K
Full Access

Injury to the syndesmosis occurs in approximately 10% of all patients with ankle fractures. Anatomic restoration of the syndesmosis is the only significant predictor of functional outcome. Several techniques of syndesmosis fixation are currently used such as cortical screws, bioabsorbable screws and more recently introduced suture-button fixation. No single technique has been shown to be superior to the others. The objective of this research project is to investigate whether treatment with a tightrope (suture-button fixation) gives superior results than the use of a cortical screw in the treatment of acute syndesmotic ankle injuries with regards to function, pain, satisfaction and return to normal activities. Research Ethics Committee approval was obtained. 40 patients with syndesmotic ankle injuries associated with diastasis were prospectively recruited, 20 in each group. Patients were randomized to one of the 2 groups. At 12 weeks, American Orthopaedic Foot and Ankle Society (AOFAS) scores and a computerized tomography (CT) scan of both the ankles was obtained. At 1 year, AOFAS scores and satisfaction was assessed. 32 patients have been recruited so far, 20 in the tightrope group and 12 in the cortical screw group. Mean AOFAS scores at 3 months post-op were 90.67 in the Tightrope group and 84 in the screw group. The difference was not significant (p= 0.096). CT scans revealed that the quality of syndesmosis reduction was equally good with both the techniques. Metalwork prominence was common with both the devices. Discussion and Conclusion. Both the devices achieved good reduction of the syndesmosis. Our CT scan protocol has insignificant radiation risk and allows more accurate assessment of the syndesmosis. Early clinical results do not show a significant difference in the functional outcome with the use of either device. Long-term (1 year) follow-up has been planned


Orthopaedic Proceedings
Vol. 90-B, Issue SUPP_I | Pages 20 - 20
1 Mar 2008
Thornes B Walsh A Shannon F Murray P Masterson E O’Brien M
Full Access

A new apparatus and technique of syndesmosis fixation is tested in a prospective clinical study. Buttons on both sides of the ankle anchor a strong suture under tension following syndesmosis reduction. This syndesmosis suture acts like a tightrope when under tension. Implantation is simple with a minimally invasive technique, as the medial side is not opened. It allows physiological micromotion whilst resisting diastasis, does not require routine removal, and allows patients to weight-bear earlier. Sixteen patients with Weber C ankle fractures with a syndesmosis diastasis underwent suture-button fixation and the results compared to 16 consecutive patients with syndesmosis screw fixation. Patients were, in effect, quasi-randomised according to surgeon preference. Mean A,O,F,A,S, ankle scores were significantly better in the suture-button group at three months post-op (91 vs 80, p=0.01, unpaired t-test) and at twelve months (93 vs 83, p=0.04, unpaired t-test). Return to work was also significantly faster (2.6 months vs 4.6 months, p=0.02, unpaired t-test). No suture-buttons required implant removal. Axial CT scanning at three months showed implants to be intact with maintenance of reduction, as compared to the uninjured contralateral side. Suture-button syndesmosis fixation is simple, safe and effective. It has shown improved outcomes and faster rehabilitation, without needing routine removal. Although the apparatus design may undergo further refinement, we believe this technique will become the treatment of choice in Weber C ankle fractures with a syndesmosis injury


Orthopaedic Proceedings
Vol. 86-B, Issue SUPP_III | Pages 255 - 255
1 Mar 2004
Thornes B Walsh A Murray P Masterson E O’Brien M
Full Access

Aims: A new technique of syndesmosis fixation is proposed; placing buttons on both sides of the ankle, without opening the medial side, connected by a strong non-absorbable suture. We tested this against syndesmosis screw fixation in a cadaver model of a Maisonneuve injury and subsequently in a prospective clinical study. Methods: 16 cadaver legs were randomised to have suture-button or syndesmosis screw fixation and tested under torque loading. In the clinical study, 16 patients with a syndesmosis diastasis underwent suturebutton fixation and the results compared to 16 patients with syndesmosis screw fixation. Results: In the cadaver study, both groups had similar rates of diastasis, although the suture-button did give a more consistent performance: standard deviations were significantly lower (p=0.001). In the clinical study, mean A.O.F.A.S. scores at 3 months were significantly better in the suturebutton group (91 vs 82, p=0.01). No suture-button implants required removal, compared to 13/16 of the screw group (p=0.001). Conclusions: Suture-button syndesmosis fixation is simple, safe and physiological. Biomechanically it performs at least as well as screw fixation. Clinically it has shown improved outcomes, without needing routine removal. It may become the treatment of choice in syndesmosis injuries


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_IV | Pages 106 - 106
1 Mar 2012
Ellanti P Ashraf M Thakaral R McCarthy T O'Sulllivan K McElwain J
Full Access

Introduction. It is recommended that the ankle be held in dorsiflexion at the time of placement of syndesmosis screw. We assessed the validity of this recommendation. Materials and methods. A two-part roentgenographic and computerised analysis of distal tibiofibular syndesmosis. The first part involved recruitment of 30 healthy adult volunteers. The second part involved 15 ankle fractures with syndesmotic injury requiring syndesmosis screw placement. In the first part individuals maximally dorsiflexed and plantarflexed their ankles in a specialised jig for standardisation. Mortice views were taken and intermalleolar distance measured. In the second part mortice views were taken in plantarflexion and dorsiflexion before and after the placement of syndesmosis screw in theatre. The intermalleolar distance was then measured. Results. In both parts of the study we found the change in intermalleolar distance between the positions of plantarflexion and dorsiflexion was not more than 0.9 mm. This change is significantly less than the calculated difference between the anterior and posterior talar body width of 3-5 mm. Conclusion. This study shows that the width of ankle mortice is independent of the position of the talus occupying it and hence dorsiflexion of the ankle at the time of syndesmosis screw placement is totally unwarranted


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XLIII | Pages 47 - 47
1 Sep 2012
Bakti N Animashawun Y Kankate R Kurup H
Full Access

Ankle fractures are one of the most common bony injuries presenting to the trauma surgeon. The more severe ones result in disruption of the tibiofibular syndesmosis and hence worse outcome. The outcome depends on accurate reduction of syndesmosis. The two main options in managing these injuries are syndesmotic screws or tightrope. The aim of this study is to compare the rate of complications between these two techniques and their radiographic results. Retrospective data from 62 patients between September 2009 and March 2011 who had fixation of syndesmosis was obtained from theatre logbooks. 46 patients had syndesmotic screws inserted while 16 had tightrope. The average age was comparable in both groups (51 years v/s 41). 25 of the 46 syndesmotic screws inserted were removed. No tightropes had to be removed for any reason. 2 patients with syndesmotic screws had wound complications while 1 patient which tightrope insertion had a persistent diastasis. There were no differences in radiological outcome between the two groups with regards to reduction of syndesmosis (measured by talofibular clear space minus medial clear space) (p-value 0.283). The difference between the talocrural angles was also of no significance (p-value 0.344). Our results indicate that tightropes achieve radiologically similar reduction of syndesmosis as screws without any significant difference in complications. The need for a second operation is significantly lower with tightrope fixation


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XIX | Pages 8 - 8
1 May 2012
Gardner R Yousri T Holmes F Clark D Pollintine P Miles A Jackson M
Full Access

Treatment of syndesmotic injuries is a subject of ongoing controversy. Locking plates have been shown to provide both angular and axial stability and therefore could potentially control both shear forces and resist widening of the syndesmosis. The aim of this study is to determine whether a two-hole locking plate has biomechanical advantages over conventional screw stabilisation of the syndesmosis in this pattern of injury. Six pairs of fresh-frozen human cadaver lower legs were prepared to simulate an unstable Maisonneuve fracture. The limbs were then mounted on a servo-hydraulic testing rig and axially loaded to a peak load of 800N for 12000 cycles. Each limb was compared with its pair; one receiving stabilisation of the syndesmosis with two 4.5mm quadricortical cortical screws, the other a two-hole locking plate with 3.2mm locking screws (Smith and Nephew). Each limb was then externally rotated until failure occurred. Failure was defined as fracture of bone or metalwork, syndesmotic widening or axial migration >2mm. Both constructs effectively stabilised the syndesmosis during the cyclical loading within 1mm of movement. However the locking plate group demonstrated superior resistance to torque compared to quadricortical screw fixation (40.6Nm vs 21.2Nm respectively, p value <0.03). Conclusion. A 2 hole locking plate (3.2mm screws) provides significantly greater stability of the syndesmosis to torque when compared with 4.5mm quadricortical fixation


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXIX | Pages 64 - 64
1 Sep 2012
Mukhopadhyay S Metcalfe A Guha A Mohanty K Hemmadi S Lyons K O'Doherty D
Full Access

Introduction. Previous studies have demonstrated the need of accurate reduction of ankle syndesmosis. Measurement of syndesmosis is difficult on plain radiographs. Recently, a difference of 2mm in anterior and posterior measurements at incisura of the inferior tibio-fibular joint on CT has been described as a measure of malreduction (depicted as ‘G’ for ease of description). Our practice changed towards routine post operative bilateral CT following syndesmosis fixation to assess the reduction and identify potential problems at an early stage. The aim of this primarily radiological study was to determine if the use of bilateral cross sectional imaging brings additional benefit above the more conventional practice of unilateral imaging. Method. Between 2007 and 2009, nineteen patients with ankle fractures involving the syndesmosis were included in the study group who had bilateral CT post operatively. The values of ‘G’ and the mean diastasis (MD) were calculated, representing the average measurement between the fibula and the anterior and posterior incisura. Results. When compared to the normal side, eight out of nineteen (42%) cases were found to have a residual diastasis even after fixation across the syndesmosis, However, if a standard value of G(2mm) was used for the injured leg only, all of the nineteen cases would have abnormal values of ‘G’ following reduction. The value of G for the injured side was poorly correlated with the mean inter-limb diastasis (MD, R=0.23). Discussion. Our study has clearly demonstrated the need for individualising the assessment method to guide surgeons and radiologists prior to revision surgery. A standard value of ‘G’ of 2mm as the normal limit cannot be applied universally as apparent from the data presented in this study


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXIII | Pages 229 - 229
1 May 2012
Yasui Y Takao M Matsushita T
Full Access

There have been few reports with efficient treatments for neglected distal tibiofibular syndesmosis disruption. Here we will report four cases of successful anatomical reconstruction with autologous gracilis tendon, using the interference fit anchoring (IFA) system. All four cases were males between 20 and 58 years of age at the time of surgery (mean age 36 years). The post-injury period to surgery was between 7 and 59 months (mean 20.1 months), with the consultation period being from 5 to 19 months (mean 9.5 months). Radiographs at the time of injuries were all malleolar fractures of pronation-external rotation (PE) stage 3 in the Lauge-Hansen classification. Stress tests for distal tibiofibular syndesmosis were positive in all cases (dilation more than 2 mm). Arthroscopic drilling was conducted in two cases with a cartilaginous injury of trochlea of talus. Distal tibiofibular syndesmosis was anatomically repositioned and was fixed with screws after bony and soft tissues within the tibiofibular syndesmosis were removed and fibular adhesion was dissected. Ipsilateral autologous gracilis tendon was passed through foramen in the insertion of the anterior inferior tibiofibular tendon on tibia and fibula, and was fixated using the IFA system. The preoperative Japanese society for surgery of the foot (JSSF) score was from 26 to 74 points (mean 43.5) and postoperative JSSF score was from 67 to 100 (mean 89.5). In a case where there was a poor outcome, five years of post injury had passed before the surgery. Although the JSSF score improved to 67 points postoperatively (from the preoperative score of 26) in this case, arthroscopic arthrodesis was conducted 5 months postoperatively due to persistent pain. Anatomical reconstruction with autologous gracilis tendon using the IFA system showed a favorable functional prognosis overall. However, there was a case with progressive degenerated changes of injured distal tibiofibular syndesmosis due to a prolonged post-injury period resulted in a poor outcome


Orthopaedic Proceedings
Vol. 86-B, Issue SUPP_IV | Pages 476 - 476
1 Apr 2004
Thornes B Hornes B Walsh A Shannon F Murray P Masterson E O’Brien M
Full Access

Introduction A new technique of ankle syndesmosis fixation is proposed. Buttons are placed on both sides of the ankle, connected by a strong non-absorbable suture. The technique is simple and minimally invasive: a medial incision is not required. It resists diastasis whilst allowing physiological micromotion and does not require routine removal. Methods The technique was tested on a cadaver model of a Maisonneuve injury under increasing torque loads. Sixteen embalmed cadaver legs were randomised to receive suture-button fixation or four-cortical 4.5 mm syndesmosis screw fixation. A prospective clinical study involving 16 patients with Weber C fractures and syndesmosis diastasis is presented. They underwent suture-button fixation and the results were compared to 16 consecutive patients with syndesmosis screw fixation. Results In the cadaver study, both groups had similar rates of diastasis following torque loading. However, the suture-button did give a more consistent performance: standard deviations were significantly lower (p=0.001) than the screw group. In the clinical study, both groups were evenly matched as regards patient age, male: female ratio, and fracture patterns. Mean AOFAS ankle outcome scores at three months were significantly better in the suture-button group (91 versus 82, p=0.01). No suture-button patients required implant removal. They had a faster return to work compared to the screw group (three months versus five months). Axial CT scanning performed at three months post-op showed all implants to be intact with no loss of reduction. Conclusions Suture-button syndesmosis fixation is simple, safe, effective and physiological. It has shown improved outcomes and faster rehabilitation, without needing routine removal. It may become the treatment of choice in Weber C ankle fractures with a syndesmosis diastasis. In relation to the conduct of this study, one or more the authors have received, or are likely to receive direct material benefits


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XVI | Pages 22 - 22
1 Apr 2012
Parkar AAH Pennington RG Abhishetty N Lahoti O
Full Access

Blount's disease is by far common cause of significant genu varum in paediatric age group. The deformity can range from simple varus deformity to significant varus, shortening of tibia and internal torsion of tibia, depending up on type and stage of Blount's disease. Several studies have shown excellent correction with the use of circular frame. The trend has moved from Ilizarov circular frame to Taylor Spatial Frame. The most accepted method of achieving correction of all components is by performing proximal tibial osteotomy and gradual correction of mechanical axis. Traditionally two additional procedures – fibular osteotomy and fixation of distal tibio-fibular syndesmosis are also added. However, the role of these additional procedures, which are not without their complications, is not well evaluated. A recent study had shown that correction of tibia vara without lengthening can be achieved without fibular osteotomy. However, use of distal tibio-fibular syndesmosis fixation (either with a wire or a screw) remains controversial. We present our experience in treating Blount's deformity with circular frame without stabilization of distal tibio-fibular syndesmosis. 10 patients were treated at our tertiary referral centre between 2000 to 2010. There were 7 boys and 3 girls. Age at surgery ranged from 8 yrs – 15 yrs. The mean patient age was 11.5 yrs. Two patients were treated with Ilizarov frame and 8 with Taylor Spatial Frame. Indications for surgery were unacceptable deformity (varus and internal rotation), with or without shortening. Varus deformity ranged from 10 degrees to 40 degrees. All tibiae were lengthened and the range of lengthening was from 1cm to 3.5cm. Fibular osteotomy was carried out in all patients. Tibio-fibular syndesmosis was never stabilized distally. All the patients were encouraged to mobilise full weight bearing as soon as tolerated and all of them had gradual correction of deformity usually starting a week following the surgery. We achieved target correction of varus, internal rotation and leg length discrepancy in all patients. The commonest hurdle was superficial pin tract infection which resolved with short courses of oral antibiotics. Follow up ranged from 6 months to 10 yrs. Clinical and radiological evaluation of ankle did not show any abnormality in all these cases. Satisfactory correction of Blount's disease (tibia vara and leg length discrepancy) can be achieved with circular frame without the stabilization of distal tibio-fibular syndesmosis