To conduct a pilot randomised controlled trial to evaluate the
feasibility of conducting a larger trial to evaluate the difference
in Victorian Institute of Sports Assessment-Achilles (VISA-A) scores
at six months between patients with Achilles tendinopathy treated
with a platelet-rich plasma (PRP) injection compared with an eccentric
loading programme. Two groups of patients with mid-substance Achilles tendinopathy
were randomised to receive a PRP injection or an eccentric loading
programme. A total of 20 patients were randomised, with a mean age
of 49 years (35 to 66). All outcome measures were recorded at baseline,
six weeks, three months and six months.Objectives
Methods
During revision total knee arthroplasty (rTKA), proximal tibial bone loss is frequently encountered and can result in a less-stable bone-implant fixation. A 3D printed titanium alloy (Ti6Al4V) revision augment that conforms to the irregular shape of the proximal tibia was recently developed. The purpose of this study was to evaluate the fixation stability of rTKA with this augment in comparison to conventional cemented rTKA. Eleven pairs of thawed fresh-frozen cadaveric tibias (22 tibias) were potted in custom fixtures. Primary total knee arthroplasty (pTKA) surgery was performed on all tibias. Fixation stability testing was conducted using a three-stage
Introduction. Tendinopathies are debilitating and painful conditions. They are believed to result from repetitive overuse, which can create micro-damage that accumulates over time, and initiates a catabolic cell response. The aetiology of tendinopathy remains poorly understood, therefore the ideal treatment remains unclear. However, current data support the use of eccentric exercise as an effective treatment. In a previous study, we have shown that
Introduction: Treatment options for the young active patient with isolated symptomatic medial compartment OA and pre-existing ACL deficiency are limited. Implant longevity and activity levels may preclude TKA, whilst HTO and unicompartmentasl knee arythroplasty (UKA) are unreliable due to ligamentous instability. UKAs tend to fail because of wear or tibial loosening resulting from
Introduction: Treatment options for the young active patient with isolated symptomatic medial compartment osteoarthritis and pre-existing anterior cruciate ligament (ACL) deficiency are limited. Implant longevity and activity levels may preclude total knee arthroplasty (TKA), whilst high tibial osteotomy HTO and unicompartmental arthroplasty (UKA) are unreliable due to ligamentous instability. UKA’s tend to fail because of wear or tibial loosening resulting from
Aim. The aim of this FE study was to analyse the comparative behaviour of cement and metal based augments in TKR and quantify the stresses within these different augments and underlying cancellous bone. Materials and methods. A three-dimensional FE model was constructed from a CT scan of the proximal tibia using SIMPLEWARE v3.2 image processing software. The tibial component of a TKR was implanted with either a block or wedge-shaped augment made of either metal or cement. The model was axially loaded with a force of 3600N and testing was conducted with both evenly and
Background. While total shoulder arthroplasty (TSA) is a generally successful procedure, glenoid loosening remains a common complication. Though the occurrence of loosening was related to patient-specific factors, biomechanical factors related to implant features may also affect the fixation of the glenoid component, in particular increased glenohumeral mismatch that could result in
Introduction. In complex primary and revision total knee replacement (TKR) the operating surgeon may encounter proximal tibial bone defects. The correct management of such defects is fundamental to both the initial stability and long-term survival of the prosthesis. Cement or metal augments have been used to address some such type II unconstrained defects [1]. Aim. The aim of this finite element (FE) study was to analyse the comparative behaviour of cement and metal based augments and quantify the stresses within these different augments and underlying cancellous bone. Materials and methods. A three-dimensional FE model was constructed from a computer tomography (CT) scan of the proximal tibia using SIMPLEWARE v3.2 image processing software. The tibial component of a TKR was implanted with either a block or wedge-shaped augment made of either metal or cement. The model was axially loaded with a force of 3600N and testing was conducted with both evenly and
Background. Distal femoral replacements (DFR) are used in children for limb-salvage procedures after bone tumor surgery. These are typically modular devices involving a hinged knee axle that has peripheral metal-on-polyethylene (MoP) and central metal-on-metal (M-M) articulations. While modular connections and M-M surfaces in hip devices have been extensively studied, little is known about long-term wear or corrosion mechanisms of DFRs. Retrieved axles were examined to identify common features and patterns of surface damage, wear and corrosion. Methods. The cobalt chromium alloy axle components from 13 retrieved DFRs were cleaned and examined by eye and with a stereo microscope up to 1000× magnification. Each axle was marked into 6 zones for visual inspection: the proximal and distal views, and the middle (M-M) and 2 peripheral (MoP) zones. The approximate percentage of the following features were recorded per zone: polishing, abrasion or scratching, gouges or detectable wear, impingement wear (i.e. from non- intentional articulation), discoloration and pitting. Results. In each case, the middle M-M zones showed more damage features compared with peripheral MoP zones. Brown discoloration, presumably due to tribofilm deposits, was the predominant M-M area feature, particularly at the junction between the MoP and M-M zones. Higher magnification showed areas of polishing underlying the discoloration, suggesting repetitive removal of the surface metal and re-deposition of tribofilms (Fig 2B). 9 cases demonstrated reflective patches resembling “thumbprint” or “fish scale” markings, which, under higher magnification, showed signs of scratching and grooving in a radial pattern (Figs 2D, 3A). Pits were occasionally present but appeared to be from third-body damage as signs of corrosion were absent. Features that resembled carbides, sometimes with associated “comet” patterns of scratching were apparent under higher magnification in some areas. The MoP zones showed variable scratching, abrasion and wear polishing. The MoP to M-M junctional areas were demarcated by a distinct band corresponding, in some cases, to a narrow wear groove or gouge. 3 axles showed evidence of severe impingement wear on one proximal end. Discussion. This study of retrieved axle components demonstrated varying types of surface wear damage but no clear evidence of corrosion. This is presumably because these parts are in nearly constant motion during gait. Third-body damage may have resulted from the breakdown of surface carbides, leading to scratching, abrasion and wear polishing under high contact stress. Severe impingement wear presumably occurred after catastrophic damage to the polyethylene bushings, allowing
The options for treatment of the young active patient with isolated symptomatic osteoarthritis of the medial compartment and pre-existing deficiency of the anterior cruciate ligament are limited. The potential longevity of the implant and levels of activity of the patient may preclude total knee replacement, and tibial osteotomy and unicompartmental knee arthroplasty are unreliable because of the ligamentous instability. Unicompartmental knee arthroplasties tend to fail because of wear or tibial loosening resulting from
Humeral head size is defined by the radius of curvature and the thickness of the articular segment. This ratio of radius to thickness is within a narrow range with an average of 0.71. The articular surface of the normal humeral head measured within the AP plane is defined by three landmarks on the non-articular surface of the proximal humerus. The perfect circle concept can be applied for assessment of the anatomic reconstruction of the post-operative x-rays and more importantly can be used intra-operatively as a guide when choosing the proper prosthetic humeral head component. The humeral head is an elliptical shape with its AP dimension being approximately 2 mm less than the SI dimension. This shape contributes to the roll and translation of the normal shoulder but is not replicated by the spherical shape of the prosthetic humeral head. The glenoid vault has a consistent 3D shape and use of the vault model within 3D planning software can define the patient's pre-morbid anatomy, specifically the location of the joint line and patient specific version and inclination. Use of this tool can assist the surgeon in defining the optimal implant and its location. In patients with little or no bone loss, a symmetric glenoid implant is often ideal for resurfacing. When there is asymmetric bone loss, often seen posteriorly with osteoarthritis, an asymmetric posteriorly augmented component can improve the ability to correct the deformity while maintaining the native joint line. It is suggested that these augmented implants in selected patients will help restore and maintain humeral alignment and lessen the risk for residual posterior humeral head subluxation and
While the vast majority of total knee replacements performed throughout the world employ a modular metal-backed tibial tray, and not an all-polyethylene tray, this issue remains controversial. Proposed advantages to a metal-backed tray include: a) decreased bending strains, b) reduces compressive stresses in the cement and cancellous bone beneath the baseplate (especially in asymmetric loading), c) distributes load more evenly across the interface. Proposed advantages of an all-polyethylene tray include: a) cost reduction, b) reduced polyethylene thickness with the same amount of bone resection, c) increased tensile stresses at the interface during
Introduction. Clinical observations suggest mid-flexion instability may occur more commonly with rotating platform (RP) total knee arthroplasty (TKA), including increased revision rates and patient-reported instability and pain. We propose that increased gap laxity leads to liftoff of the lateral femoral condyle with decreased conformity between the femoral component and polyethylene (PE) insert surface leading to PE subluxation or dislocation. The objectives of this study were to define “at risk” loading conditions that predispose patients to PE insert subluxation or spinout, and to quantify the margin of error for flexion/extension gap laxity in preventing these adverse events under physiologic loading conditions. Methods. Biomechanical testing was performed on six fresh frozen cadaveric knees implanted with a posterior stabilized RP TKA using a gap balancing technique. Rotational displacement and torque were measured over time, while stiffness, yield torque, max torque and displacement were calculated using a post-processing, custom MatLab code. Revision with varying size femoral components (size 3–6) and PE insert thicknesses (10–15mm), by downsizing one step, were used to create a spectrum of flexion/extension gap mismatch. Each configuration was subjected to three loaded testing conditions (0°, 30° and 60° flexion) in balanced and
Cervical total disc replacement has been in practice for years now as a viable alternative to cervical fusion in suitable cases, aspiring to preserve spinal motion and prevent adjacent segment disease. Reports are rife that neck pain emerges as an annoying feature in the early postoperative period. The facet joint appears to be the most likely source of pain. 50 patients were prospectively followed up through 5 years after having received disc replacement surgery, indicated for symptomatic soft disc herniation of the cervical spine presenting with radiculopathy. • All were skeletally mature and aged between 22 to 50. • All had failed a minimum of 6 months conservative therapy. • Up to 2 disc levels were addressed. C3 till C7 levels. • Single surgeon (first author). • NDI > 30% (15/50). • Deteriorating radicular neurology. We excluded those with degenerative trophic changes of the cervical spine, focal instability, trauma, osteoporosis, previous cervical spine surgery, previous infection, ossifying axial skeletal disease and inflammatory spondyloarthritides. The device used was an unconstrained implant with stabilizing teeth. Over the 5 years, we studied their postoperative comfort level via the Neck Disability Index (NDI) and Visual Analogue Score (VAS). Pre-operative and post-operative analysis of the sagittal axis and of involved facet joints were done. 22 patients suffered postoperative neck pain as reflected by the NDI and VAS scores. Of these, 10 reported of neck pain even 24 months after surgery. However, none were neurologically worse and all patients returned to their pre-morbid functions and were relieved of pain by 28 months. All 22 patients reported of rapid dissolution of neckache after peri-facetal injections of steroids were done under image guidance. We draw attention to the facet joint as the pain generator, triggered by inappropriate implant height, eccentric stresses via hybrid constructs,
Introduction. The effectiveness of patient specific instrumentation (PSI) to perform total knee arthroplasty (TKA) remains controversial. Multiple studies have been published that reveal conflicting results on the effectiveness of PSI, but no study has analyzed the contact kinematics within knee joints replaced with the use of PSI. Since a departure from normal kinematics can lead to
Shoulder arthroplasty is the treatment of choice for a range of degenerative diseases. However, long term follow-up suggests almost half of patients graded their treatment as unsatisfactory. Component malalignment is thought the most likely cause. The anterior anatomical neck is used as a reference for the osteotomy. The objective of the study was to analyse the cartilage/metaphyseal interface to identify reference points that may recover version accurately. Twenty-four humeri were scanned using a Microscribe digitiser and surface laser scanner. Modelling software was used to analyse the Cartilage/metaphyseal interface. The retroversion angle was calculated for the normal geometry and for the standard osteotomy. An ideal osteotomy plane was then created for each specimen and the distance from the cartilage/metaphyseal interface determined, identifying points of least deviation. The reference points were used to simulate a new osteotomy for which retroversion was calculated. The novel osteotomy and traditional osteotomy were compared to the normal geometry. The mean retroversion for the normal geometry was 18.5±9.0 degrees. The mean retroversion for the traditional osteotomy technique was 29.5±10.7 degrees, significantly different from the original (p<0.001). The mean retroversion using the novel osteotomy was 18.9±8.9 degrees and similar to the normal geometry (p=0.528). The traditional osteotomy resulted in a mean increase in retroversion of 38%. The increase in version may result in
The anterior portion of the anatomical neck is used as a reference for the osteotomy in shoulder arthroplasty. Resection at this level is thought to remove a segment of a sphere which can accurately be replaced with a prosthetic implant. The objective of the study was to analyse the cartilage/metaphyseal interface relative to an ideal osteotomy plane to define points of reference the may recover retroversion accurately. Data were collected from 24 humeri using a novel technique, combining data acquired using a Microscribe digitiser and surface laser scanner. Rhinocerus NURBS modelling software was used to analyse the Cartilage/metaphyseal interface. The retroversion angle was calculated for the normal geometry and for the standard osteotomy along the anterior cartilage/metaphyseal interface. An ideal osteotomy plane was then created for each specimen and the perpendicular distance from the cartilage/metaphyseal interface was determined, identifying points of least deviation. The reference points were used to simulate a new osteotomy for which retroversion was calculated. Paired t-tests were used to compare the novel osteotomy and traditional osteotomy to the normal geometry. The mean retroversion for the normal geometry was 18.5±9.0 degrees. The mean retroversion for the traditional osteotomy technique was 29.5±10.7 degrees, significantly different from the original (p< 0.001). The mean retroversion using the novel osteotomy was 18.9±8.9 degrees and similar to the normal geometry (p=0.528). The traditional osteotomy resulted in a mean increase in retroversion of 38%. The increase in version may result in
ECSWT has been on the medical horizon for last 30 years mainly in urology for urolithiasis and has found a parallel use in orthopaedics for various chronic soft tissue conditions like Tendoachilles tendinoses and plantar fasciitis etc. ECSWT acts a piezoelectric device releasing acoustic energy and causing micro-trauma activating cytokine mediated response stimulating local angiogenesis and tissue repair. Methodology. 56 patients were recruited for the trial after ethics approval was achieved. The diagnosis was confirmed with ultrasound scan and measuring the width of the swelling and the local hypervascularity. The cohort of the patients was randomised in groups for physiotherapy [n=23] and shockwave therapy [n= 23]. The patient groups with shockwave therapy received a 3-week treatment with typical 2000 impulses per session once a week and physiotherapy group was subjected to
The tibial component of total knee arthroplasty can either be an all-polyethylene (AP) implant or a metal-backed (MB) implant. This study aims to compare the five-year functional outcomes of AP tibial components to MB components in patients aged over 70 years. Secondary aims are to compare quality of life, implant survivorship, and cost-effectiveness. A group of 130 patients who had received an AP tibial component were matched for demographic factors of age, BMI, American Society of Anesthesiologists (ASA) grade, sex, and preoperative Knee Society Score (KSS) to create a comparison group of 130 patients who received a MB tibial component. Functional outcome was assessed prospectively by KSS, quality of life by 12-Item Short-Form Health Survey questionnaire (SF-12), and range of motion (ROM), and implant survivorships were compared. The SF six-dimension (6D) was used to calculate the incremental cost effectiveness ratio (ICER) for AP compared to MB tibial components using quality-adjusted life year methodology.Aims
Methods
The direction of wear in the acetabular socket has implications for the amount of debris that is generated during movement, for the magnitude of
Problem: The displacement of the rotation centre of the humeral head in relation to the shaft axis strongly varies individually. In order to measure the position of the pivot points of the head, the Affinis shoulder prosthesis has a double eccentric adjustment possibility that permits to adapt the head to the medial and dorsal offset. So far, such examinations took place exclusively on the anatomical preparation. This raises the question of whether the need for such a prosthetic system can be derived from the anatomical variation of the pivot points. Method: In 126 patients with an Affinis shoulder prosthesis, we calculated the individual rotation centres of the head from the position of the adjustable prosthetic cone and the eccentric position of the head. In addition, we used the Constant Score to record the clinical function. Results: We found great variation of the rotational centres. Therefore we needed the entire setting range of 12mm mediolateral and 6mm dorsoventral. The examination showed that none of the found anatomic head centres could have been reconstructed exactly with a conventional prosthesis. Prosthesis with a single eccentricity would allow correct adjustment in only 22 cases, as the adjustable rotational centres of the head are situated on a circle, which limits the setting possibilities. The Constant Score of the total group improved from 29% preoperatively to 94% after 2 years. Conclusions: The high variation of the head centres indicates the necessity of a freely adjustable system, such as in a double eccentric bearing. This is the only way that permits an optimal reconstruction of the anatomical conditions – it prevents an increased tension of the rotator cuff, reduces the
Purpose of the study: Rotation of the tibial implant is an important factor for the functional outcome of total knee arthroplasty (TKA). Any rotational malposition will cause
Purpose: Finite element analysis can be used to assess the behaviour of loaded structures. We used this method to evaluate the influence of glenoid implant design on the behaviour of an osteoarthritic scapula. Material and methods: A 76-year-old female patient scheduled for a shoulder prosthesis underwent preoperative computed tomography of the osteoarthritic shoulder. Two polyethylene implants were evaluated: one with a triangular stem and the same prosthesis with three studs. 3D reconstruction of the glenoid cavity with the implants was then obtained and processed with the finite elements method. Three loadings were applied to the model: centred loading to reproduce the case of an ideally stable prosthesis with a normal tendinomuscular environment and excentred loading to simulate a deficient rotator cuff or prosthesis instability. Results: With centred loading, stress remained low, to the order of 7 MPa, at the stem-glenoid cavity interface. Excentered loading produced peak stress on the borders of the glenoid implants, directly under the loading zone and at the tip of the stem, at the bone-cement interface, reaching 20 MPa. The implant tended to bend in the anteroposterior direction producing strong shear forces on the posterior part of the glenoid cavity. These forces caused micromovement at the cement-bone interface. There was no significant difference between the stem and stud implants. Discussion:
To compare the effect of standard non-offset and offset humeral heads on early glenoid loosening. From 2002–2004 in a prospective study, 12 patients with osteoarthritis and intact rotator cuff had a TSR with an offset humeral head matching normal anatomy. Five tantalum markers were introduced into the scapula and acromion, spaced widely apart; four markers were placed in a pegged glenoid component. RSA radiographs were taken postoperatively, three, six, twelve months. The micromotion of this offset head group was compared with a baseline series of TSRs with standard non offset humeral head implants which had previously been measured over 24 months. At 24 months, the largest segment translation for the offset head group was in the anterior/posterior direction with a mean of 0.24mm, the standard head group mean was 0.61mm, t=1.3,P=0.21. Proximal/distal translation gave means of 0.51mm (standard head) and 0.17mm (offset head), t=1.3,P=0.21. Medial/lateral translation was smallest for the offset group with mean 0.16mm this is less than half the standard group mean 0.57mm and is significant, t=1.4,P=0.19. The largest rotation was anteversion/retroversion with a mean of 1.50 (offset) compared to 4.40 (standard), t=2.3, P=0.04. Varus/valgus tilt differed significantly with means 0.90 (offset) and 2.50 (standard), t=3.8,P=0.001; and finally anterior/posterior tilt had smallest means of 0.70 (offset) and 1.00 (standard), t=1.2,P=0.25. Maximum total point motion was also significantly different at 24 months, means of 0.66mm (offset) compared to 1.65mm (standard), t=2.3,P=0.04. Early migration occurs in both groups of pegged components. A principal component micromotion index illustrates the complexity of micromotion. Offset heads move significantly less than the standard type, the significant differences in MTPM movement and in rotation (varus/valgus tilt) suggest that the offset head may decrease
The February 2023 Research Roundup360 looks at: Clinical and epidemiological features of scaphoid fracture nonunion; Routine sterile glove and instrument change at the time of abdominal wound closure to prevent surgical site infection (ChEETAh); Characterization of genetic risk of end-stage knee osteoarthritis treated with total knee arthroplasty; Platelet-rich plasma or autologous blood injection for plantar fasciitis; Volume and outcomes of joint arthroplasty; The hazards of absolute belief in the p-value laid bare.
The December 2022 Shoulder & Elbow Roundup360 looks at: Biceps tenotomy versus soft-tissue tenodesis in females aged 60 years and older with rotator cuff tears; Resistance training combined with corticosteroid injections or tendon needling in patients with lateral elbow tendinopathy; Two-year functional outcomes of completely displaced midshaft clavicle fractures in adolescents; Patients who undergo rotator cuff repair can safely return to driving at two weeks postoperatively; Are two plates better than one? A systematic review of dual plating for acute midshaft clavicle fractures; Treatment of acute distal biceps tendon ruptures; Rotator cuff tendinopathy: disability associated with depression rather than pathology severity; Coonrad-Morrey total elbow arthroplasty implications in young patients with post-traumatic sequelae.
Injuries to the quadriceps muscle group are common in athletes performing high-speed running and kicking sports. The complex anatomy of the rectus femoris puts it at greatest risk of injury. There is variability in prognosis in the literature, with reinjury rates as high as 67% in the severe graded proximal tear. Studies have highlighted that athletes can reinjure after nonoperative management, and some benefit may be derived from surgical repair to restore function and return to sport (RTS). This injury is potentially career-threatening in the elite-level athlete, and we aim to highlight the key recent literature on interventions to restore strength and function to allow early RTS while reducing the risk of injury recurrence. This article reviews the optimal diagnostic strategies and classification of quadriceps injuries. We highlight the unique anatomy of each injury on MRI and the outcomes of both nonoperative and operative treatment, providing an evidence-based management framework for athletes. Cite this article:
Purpose: The purpose of this biomechanical study was to assess: (1) the effect of thoracic vertebral compression fracture (VCF) on kyphosis and physiologic compressive load path, and (2) the effect of balloon kyphoplasty and spinal extension on restoration of normal geometric and loading alignment. Methods: Six fresh human thoracic specimens, each consisting of three adjacent vertebrae were used. In order to create a VCF, IBTs were placed transpedicularly into the middle VB and cancellous bone was disrupted by inflation of IBTs. After cancellous bone disruption the specimens were compressed using bilateral loading cables until a fracture was observed. Fracture reduction by spinal extension, and then by balloon kyphoplasty was performed under a physiologic compressive preload of 250 N. The vertebral body heights, kyphotic deformity, and location of compressive load path were measured on video-fluoroscopy images. Results: The VCF caused anterior VB height loss of 3715%, middle-height loss of 3416%, segmental kyphosis increase of 147.0 degrees, and vertebral kyphosis increase of 135.5 degrees (p<
0.05). The compressive load path shifted anteriorly by 20% of A-P endplate width in the fractured and adjacent VBs (p=0.01). IBT inflation alone restored anterior VB height to 918.9%, middle-height to 9114%, and segmental kyphosis to within 5.65.9 degrees of pre-fracture values. The compressive load path returned posteriorly in all three VBs (p=0.00): the load path remained anterior to the pre-fracture location by 9–11% of the A-P endplate width. The extension moment fully restored the compressive load path to its pre-fracture location. Under this moment, the anterior and middle VB heights were restored to 858.6% and 749.4% of pre-fracture values, respectively. The segmental kyphosis was fully restored to its pre-fracture value; however, the middle height and kyphotic deformity of the fractured VB remained smaller than the pre-fracture values (p<
0.05). Conclusions: An anterior shift of the compressive load path in VBs adjacent to VCF can induce additional flexion moments. The
In this study, we aimed to explore surgical variations in the Femoral Neck System (FNS) used for stable fixation of Pauwels type III femoral neck fractures. Finite element models were established with surgical variations in the distance between the implant tip and subchondral bone, the gap between the plate and lateral femoral cortex, and inferior implant positioning. The models were subjected to physiological load.Aims
Methods
Introduction. Varying degrees of posterior glenoid bone loss occurs in patients with end stage osteoarthritis and can result in increased glenoid retroversion. The excessive retroversion can affect implant stability,
Higher osteoblastic bone activity is expected in aseptic loosening and painful unicompartmental knee arthroplasty (UKA). However, insights into normal bone activity patterns after medial UKAs are lacking. The aim of this study was to identify the evolution in bone activity pattern in well-functioning medial mobile-bearing UKAs. In total, 34 patients (13 female, 21 male; mean age 62 years (41 to 79); BMI 29.7 kg/m2 (23.6 to 42.1)) with 38 medial Oxford partial UKAs (20 left, 18 right; 19 cementless, 14 cemented, and five hybrid) were prospectively followed with sequential 99mTc-hydroxymethane diphosphonate single photon emission CT (SPECT)/CT preoperatively, and at one and two years postoperatively. Changes in mean osteoblastic activity were investigated using a tracer localization scheme with volumes of interest (VOIs), reported by normalized mean tracer values. A SPECT/CT registration platform additionally explored cortical tracer evolution in zones of interest identified by previous experimental research.Aims
Methods
To investigate and compare the biomechanical characteristics of Bipedicular versus Unipedicular Vertebroplasty in cadaveric vertebra. Cadaveric single level vertebra were used to evaluate Bipedicular versus Unipedicular Vertebroplasty as an intervention for vertebral compression fractures. Cadaveric vertebra were assigned to two arms: Arm A simulated a wedge fracture followed by bipedicular cement augmentation; Arm B simulated a wedge fracture followed by unipedicular cement augmentation. Micro-CT imaging was performed to assess vertebral dimension, cement fill volumes and bone mineral density. All augmented specimens were then compressed under a static
In femoral locked nailing, the distal locking screws is vulnerable to mechanical failure. The stress on these screws is substantially affected by fitness of the nail in the medullary canal. In this study a closed form mathematical model based on elastic column-beam theory is developed to investigate how the nail-cortical contact which is simulated by a linear elastic foundation affects the stress of the distal locking screws. The model is comprised of a construct of a fractured femur with an intramedullay locked nail loaded by an
Fusion remains the standard of care and is associated with a high satisfaction rate. But.… fusion generally requires 6 weeks of restricted weight bearing or immobilization. Potential problems include 1) nonunion, 2) malunion, 3) sesamoid pain (from DJD), 4) late onset IP1 DJD. Complete joint replacement has been performed with a number of different designs since the early 1970's. The metal and poly designed implants are associated with a high failure rate, presumably from high shear
Patient-specific instrumentation has been shown to increase a surgeon’s precision and accuracy in placing the glenoid component in shoulder arthroplasty. There is, however, little available information about the use of patient-specific planning (PSP) tools for this operation. It is not known how these tools alter the decision-making patterns of shoulder surgeons. The aim of this study was to investigate whether PSP, when compared with the use of plain radiographs or select static CT images, influences the understanding of glenoid pathology and surgical planning. A case-based survey presented surgeons with a patient’s history, physical examination, and, sequentially, radiographs, select static CT images, and PSP with a 3D imaging program. For each imaging modality, the surgeons were asked to identify the Walch classification of the glenoid and to propose the surgical treatment. The participating surgeons were grouped according to the annual volume of shoulder arthroplasties that they undertook, and responses were compared with the recommendations of two experts.Aims
Methods
Accurate measurement of the glenoid version is important in performing total shoulder arthroplasty (TSA). Our aim was to evaluate the Ellipse method, which involves formally defining the vertical mid-point of the glenoid prior to measuring the glenoid version and comparing it with the ‘classic’ Friedman method. This was a retrospective study which evaluated 100 CT scans for patients who underwent a primary TSA. The glenoid version was measured using the Friedman and Ellipse methods by two senior observers. Statistical analyses were performed using the paired Aims
Methods
INTRODUCTION: In the spinal column, bone metastases (BM) and lesions arising from multiple myeloma (MM) can cause severe weakening of the vertebral body (VB) leading to an increased risk of fracture. 1. These vertebral fractures may induce severe pain, deformity and increased risk of neurological deficit. 2. At present, however, there is very little known about the mechanical behaviour either of the infiltrated vertebrae or that following vertebroplasty (VP). The purpose of this preliminary investigation was to evaluate (i) the mechanical behaviour of vertebrae with lesion involvement, and (ii) the effectiveness of VP with coblation. METHODS: Individual vertebrae from two spines, one with MM (n=13) and one with BM secondary to bladder cancer (n=12) were dissected free of soft tissue with the posterior elements retained. Three MM vertebrae with evidence of previous fracture were excluded. Each vertebrae was fractured under an
Patients with a deformity of the hindfoot present a particular challenge when performing total knee arthroplasty (TKA). The literature contains little information about the relationship between TKA and hindfoot alignment. This systematic review aimed to determine from both clinical and radiological studies whether TKA would alter a preoperative hindfoot deformity and whether the outcome of TKA is affected by the presence of a postoperative hindfoot deformity. A systematic literature search was performed in the databases PubMed, EMBASE, Cochrane Library, and Web of Science. Search terms consisted of “total knee arthroplasty/replacement” combined with “hindfoot/ankle alignment”. Inclusion criteria were all English language studies analyzing the association between TKA and the alignment of the hindfoot, including the clinical or radiological outcomes. Exclusion criteria consisted of TKA performed with a concomitant extra-articular osteotomy and case reports or expert opinions. An assessment of quality was conducted using the modified Methodological Index for Non-Randomized Studies (MINORS). The review was performed according to the Preferred Reporting Items for Systematic Reviews and Meta-analyses (PRISMA) guidelines and registered in the PROSPERO database (CRD42019106980).Aims
Methods
Introduction: Realigning the foot and good ligament balancing have been recognized to be the mainstay for successful reconstruction of complex hindfoot disorders and deformities. This is particularly true for posttraumatic conditions, where deformities and scarring might be the underlying cause of foot dysfunction. For surgical reconstruction, i.e. osteotomies, arthrodeses and total ankle replacement, references are needed for restoration of the anatomy and the function. Most surprisingly to date no data is available regarding dimensions on standard X-rays of the hindfoot. The purpose of this prospective study therefore was 1) to define relevant and reproducible measures on lateral hindfoot X-rays and 2) to assess their reliability. Methods: 100 lateral view X-rays were taken. Dimensions assessed were the talar area covered by the tibia, the angle of the distal tibial joint plane to the tibial axis (tilt), the width of the tibia on the joint level, the height of the talus, the joint radius of the ankle joint and the offset of the centre of rotation from the tibial axis. Results: The tibial coverage of the talus was 88.1 degrees (SD = 0.36), the angle of the distal tibial joint plane to the tibial axis (tilt) was 83 degrees (SD 3.6), the width of the distal tibia 33.6 mm (SD = 2.4), the radius of the ankle joint 18.6 mm (SD = 4.0) with an anterior offset of the centre of rotation of 1.7 mm and the height of the talus was 28.2 mm (SD = 2.1). Conclusions: In case of symptomatic deformity any reconstruction, i.e. correcting osteotomies, ligament reconstruction, arthrodeses or arthroplasty, should aim to correct the foot in a physiological way; respecting the original dimensions of the hindfoot to achieve maximal benefit. Anterior-posterior translation of the talus may be a source of pain, restriction of motion and a cause of degenerative joint disease because of
The primary objective of this study was to compare accuracy in restoring the native centre of hip rotation in patients undergoing conventional manual total hip arthroplasty (THA) This prospective cohort study included 50 patients undergoing conventional manual THA and 25 patients receiving robotic-arm assisted THA. Patients undergoing conventional manual THA and robotic-arm assisted THA were well matched for age (mean age, 69.4 years (Objectives
Materials and Methods
The Walch Type C dysplastic glenoid is characterized by excessive
retroversion. This anatomical study describes its morphology. A total of 29 shoulders with a dysplastic glenoid were analyzed.
CT was used to measure retroversion, inclination, height, width,
radius-of-curvature, surface area, depth, subluxation of the humeral
head and the Goutallier classification of fatty infiltration. The
severity of dysplasia and deficiency of the posterior rim of the
glenoid were recorded.Aims
Patients and Methods
Controversy about the use of an anatomical total shoulder arthroplasty
(aTSA) in young arthritic patients relates to which is the ideal
form of fixation for the glenoid component: cemented or cementless.
This study aimed to evaluate implant survival of aTSA when used
in patients aged < 60 years with primary glenohumeral osteoarthritis (OA),
and to compare the survival of cemented all-polyethylene and cementless
metal-backed glenoid components. A total of 69 consecutive aTSAs were performed in 67 patients
aged < 60 years with primary glenohumeral OA. Their mean age
at the time of surgery was 54 years (35 to 60). Of these aTSAs,
46 were undertaken using a cemented polyethylene component and 23
were undertaken using a cementless metal-backed component. The age, gender,
preoperative function, mobility, premorbid glenoid erosion, and
length of follow-up were comparable in the two groups. The patients
were reviewed clinically and radiographically at a mean of 10.3
years (5 to 12, Aims
Materials and Methods
In recent years, the plantaris tendon has been
implicated in the development of chronic painful mid-portion Achilles tendinopathy.
In some cases, a thickened plantaris tendon is closely associated
with the Achilles tendon, and surgical excision of the plantaris
tendon has been reported to be curative in patients who have not
derived benefit following conservative treatment and surgical interventions. The aim of this review is to outline the basic aspects of, and
the recent research findings, related to the plantaris tendon, covering
anatomical and clinical studies including those dealing with histology,
imaging and treatment. Cite this article
Secondary fracture healing is strongly influenced by the stiffness of the bone-fixator system. Biomechanical tests are extensively used to investigate stiffness and strength of fixation devices. The stiffness values reported in the literature for locked plating, however, vary by three orders of magnitude. The aim of this study was to examine the influence that the method of restraint and load application has on the stiffness produced, the strain distribution within the bone, and the stresses in the implant for locking plate constructs. Synthetic composite bones were used to evaluate experimentally the influence of four different methods of loading and restraining specimens, all used in recent previous studies. Two plate types and three screw arrangements were also evaluated for each loading scenario. Computational models were also developed and validated using the experimental tests.Objectives
Methods
The February 2014 Foot &
Ankle Roundup360 looks at: optimal medial malleolar fixation; resurfacing in the talus; predicting outcome in mobility ankles; whether mal-aligned ankles can be successfully replaced; cartilage colonisation in bipolar ankle grafts; CTs and proof of fusion; recalcitrant Achilles tendinopathy; and recurrent fifth metatarsal stress fractures.
The October 2014 Shoulder &
Elbow Roundup360 looks at: PRP is not effective in tennis elbow; eccentric physiotherapy effective in subacromial pain; dexamethasone in shoulder surgery; arthroscopic remplissage for engaging Hill-Sach’s lesions; a consistent approach to subacromial impingement; delay in fixation of proximal humeral fractures detrimental to outcomes.
One goal of total hip arthroplasty is to restore normal hip anatomy.
The aim of this study was to compare displacement of the centre
of rotation (COR) using a standard reaming technique with a technique
in which the acetabulum was reamed immediately peripherally and
referenced off the rim. In the first cohort the acetabulum was reamed to the floor followed
by sequentially larger reamers. In the second cohort the acetabulum
was only reamed peripherally, starting with a reamer the same size
as the native femoral head. Anteroposterior pelvic radiographs were
analysed for acetabular floor depth and vertical and horizontal position
of the COR.Aims
Patients and Methods
Patellar instability most frequently presents
during adolescence. Congenital and infantile dislocation of the
patella is a distinct entity from adolescent instability and measurable
abnormalities may be present at birth. In the normal patellofemoral
joint an increase in quadriceps angle and patellar height are matched
by an increase in trochlear depth as the joint matures. Adolescent
instability may herald a lifelong condition leading to chronic disability
and arthritis. Restoring normal anatomy by trochleoplasty, tibial tubercle transfer
or medial patellofemoral ligament (MPFL) reconstruction in the young
adult prevents further instability. Although these techniques are
proven in the young adult, they may cause growth arrest and deformity
where the physis is open. A vigorous non-operative strategy may
permit delay of surgery until growth is complete. Where non-operative
treatment has failed a modified MPFL reconstruction may be performed
to maintain stability until physeal closure permits anatomical reconstruction.
If significant growth remains an extraosseous reconstruction of
the MPFL may impart the lowest risk to the physis. If minor growth
remains image intensifier guided placement of femoral intraosseous
fixation may impart a small, but acceptable, risk to the physis. This paper presents and discusses the literature relating to
adolescent instability and provides a framework for management of
these patients. Cite this article: