There is a paucity of data available for the use of Total Femoral Arthroplasty (TFA) for joint reconstruction in the non-oncological setting. The aim of this study was to evaluate TFA outcomes with minimum 5-year follow-up. This was a retrospective database study of TFAs performed at a UK tertiary referral revision arthroplasty unit. Inclusion criteria were patients undergoing TFA for non-oncological indications. We report demographics, indications for TFA, implant survivorship, clinical outcomes, and indications for re-operation. A total of 39 TFAs were performed in 38 patients between 2015–2018 (median age 68 years, IQR 17, range 46–86), with 5.3 years’ (IQR 1.2, 4.1–18.8) follow-up; 3 patients had died. The most common indication (30/39, 77%) for TFA was periprosthetic joint infection (PJI) or fracture-related infection (FRI); and 23/39 (59%) had a prior periprosthetic fracture (PPF). TFA was performed with dual-mobility or constrained cups in 31/39 (79%) patients. Within the cohort, 12 TFAs (31%) required subsequent revision surgery: infection (7 TFAs, 18%) and instability (5 TFAs, 13%) were the most common indications. 90% of patients were ambulatory post-TFA; 2 patients required disarticulation due to recurrent PJI. While 31/39 (79%) were infection free at last follow-up, the remainder required long-term suppressive antibiotics. This is the largest series of TFA for non-oncological indications. Though TFA has inherent risks of instability and infection, most patients are ambulant after surgery. Patients should be counselled on the risk of life-long antibiotics, or disarticulation when TFA fails.
A proportion of patients with hip and knee prosthetic joint infection (PJI) undergo multiple revisions with the aim of eradicating infection and improving quality of life. The aim of this study was to describe the microbiology cultured from multiply revised hip and knee replacement procedures to guide antimicrobial therapy at the time of surgery. Consecutive patients were retrospectively identified from databases at two specialist orthopaedic centres in the United Kingdom between 2011 and 2019. Patient were included who had undergone repeat revision total knee replacement (TKR) or total hip replacement (THR) for infection, following an initial failed revision for infection.Introduction
Patients and Methods
Primary total hip replacement (THR) is a successful and common operation which orthopaedic trainees must demonstrate competence in prior to completion of training. This study aimed to determine the impact of operating surgeon grade and level of supervision on the incidence of 1-year patient mortality and all-cause revision following elective primary THR in a large UK training centre. National Joint Registry (NJR) data for all elective primary THR performed in a single University Teaching Hospital from 2005–2020 were used, with analysis performed on the 15-year dataset divided into 5-year temporal periods (B1 2005–2010, B2 2010–2015, B3 2015–2020). Outcome measures were mortality and revision surgery at one year, in relation to lead surgeon grade, and level of supervision for trainee-led operations. 9999 eligible primary THR were undertaken, of which 5526 (55.3%) were consultant led (CL), and 4473 (44.7%) trainees led (TL). Of TL, 2404 (53.7%) were non-consultant supervised (TU), and 2069 (46.3%) consultant supervised (TS). The incidence of 1-year patient mortality was 2.05% (n=205), and all-cause revision was 1.11% (n=111). There was no difference in 1-year mortality between TL (n=82, 1.8%) and CL (n=123, 2.2%) operations (p=0.20, OR 0.78, CI 0.55–1.10). The incidence of 1-year revision was not different for TL (n=56, 1.3%) and CL (n=55, 1.0%) operations (p=0.15, OR 1.37, CI 0.89–2.09). Overall, there was no temporal change for either outcome measure between TL or CL operations. A significant increase in revision within 1-year was observed in B3 between TU (n=17, 2.7%) compared to CL (n=17, 1.0%) operations (p=0.005, OR 2.81, CI 1.35–5.87). We found no difference in 1-year mortality or 1-year all-cause revision rate between trainee-led primary THR and consultant-led operations over the entire fifteen-year period. However, unsupervised trainee led THR in the most recent 5-year block (2015–2020) has a significantly increased risk of early revision, mainly due to instability and prosthetic joint infection. This suggests that modern surgical training is having a detrimental effect on THR patient outcomes. More research is needed to understand the reasons if this trend is to be reversed.
Unicompartmental knee arthroplasty (UKA) is an effective treatment for late knee osteoarthritis (OA). However, its indications remain controversial. Young age (< 60 years) has been associated with worse outcomes. The goal of this systematic review and meta-analysis is to study the effect of age on UKA outcomes. The primary objective was to compare the UKA revision rate in young patients with that of old patients, using the age thresholds of 60 and 55 years. Secondary objectives were patient-reported outcome measures (PROMs) and implant design. PubMed, Ovid, Web of Science, Google Scholar, and Cochrane library were searched in June 2021. This review was conducted in accordance with the PRISMA guidelines (PROSPERO registration number: CRD42021248322).Abstract
Purpose
Methods
Cementless fixation of Oxford Unicompartmental Knee Replacements (UKRs) is an alternative to cemented fixation, however, it is unknown whether cementless fixation is as good long-term. This study aimed to compare primary and long-term fixation of cemented and cementless Oxford UKRs using radiostereometric analysis (RSA). Twenty-nine patients were randomised to receive cemented or cementless Oxford UKRs and followed for ten years. Differences in primary fixation and long-term fixation of the tibial components (inferred from 0/3/6-month and 6-month/1-year/2-year/5-year/10-year migration, respectively) were analysed using RSA and radiolucencies were assessed on radiographs. Migration rates were determined by linear regression and clinical outcomes measured using the Oxford Knee Score (OKS).Abstract
Introduction
Methodology
The primary aim of this study was to evaluate the outcomes of fungal knee periprosthetic joint infection following knee arthroplasty. The secondary aim was to evaluate risk factors for acquiring a fungal PJI. This was a retrospective analysis of patients presenting with a confirmed fungal PJI of the knee in two tertiary centres. There were a total of 45 cases. Isolated fungal infections along with mixed bacterial and fungal infections were included. Mean follow up was 40 months (range 3–118).Abstract
Aims
Patients and Methods
This study assesses the ability of the JS-BACH classification of bone infection to predict clinical and patient-reported outcomes in prosthetic joint infection (PJI). Patients who received surgery for suspected PJI at two specialist bone infection centres within the UK between 2010 and 2015 were classified using the JS-BACH classification into either ‘uncomplicated’, ‘complex’ or ‘limited options’. All patients were classified by two clinicians blinded to outcome, with any discrepancies adjudicated by a third reviewer. At the most recent follow-up, patients were assessed for (i) any episode of recurrence since the index operation and (ii) the status of the joint. A Cox proportional-hazard model assessed significant predictors of recurrence following the index procedure. Patient-reported outcomes included the EuroQol EQ-5D-3L index score and the EQ-visual analogue score (VAS) at 0, 14, 42, 120 and 365 days following the index operation.Aim
Method
Cemented total hip replacement (THR) provides excellent outcomes and is cost-effective. Polished taper-slip (PTS) stems demonstrate successful results and have overtaken traditional composite-beam (CB) stems. Recent reports indicate they are associated with a higher risk of postoperative periprosthetic femoral fracture (PFF) compared to CB stems. This study evaluates risk factors influencing fracture characteristics around PTS and CB cemented stems. Data were collected for 584 PFF patients admitted to eight UK centres from 25/05/2006-01/03/2020. Radiographs were assessed for Unified Classification System (UCS) grade and Arbeitsgemeinschaft für Osteosynthesefragen/Orthopaedic Trauma Association (AO/OTA) type. Statistical comparisons investigated relationships by age, gender, and stem fixation philosophy (PTS versus CB). The effect of multiple variables was estimated using multinomial logistic regression to estimate odds ratios (OR) with 95% confidence intervals (CI). Median (IQR) age was 79.1 (72.0–86.0) years, 312 (53.6%) patients were female, and 495 (85.1%) stems were PTS. The commonest UCS grade was type B1 (278, 47.6%). The commonest AO/OTA type was spiral (352, 60.3%). Metaphyseal-split fractures occurred only with PTS stems with an incidence of 10.1%. Male gender was associated with a five-fold reduction in odds of a type C fracture (OR 0.22, 95% CI 0.12 to 0.41, p<0.001) compared to a type B fracture. CB stems were associated with significantly increased odds of transverse fracture (OR 9.51, 95% CI 3.72 to 24.34, p <0.001) and wedge fracture (OR 3.72, 95% CI 1.16 to 11.95, p <0.05) compared to PTS stems. This is the largest study investigating PFF characteristics around cemented stems. The commonest fracture types are B1 and spiral fractures. PTS stems are exclusively associated with metaphyseal-split fractures, but their incidence is low. Males have lower odds of UCS grade C fractures compared to females. CB stems had higher odds of bending type fractures (transverse and wedge) compared to PTS stems. Biomechanical testing is needed for validation and investigation of modifiable factors which may reduce the risk of unstable fracture patterns requiring complex revision surgery over internal fixation.
Treatment of periprosthetic joint infection (PJI) can include local delivery of antibiotics. A frequently used medium is absorbable calcium sulphate beads. The aims of this study were to:
identify how often organisms in infected THRs are sensitive to the added antibiotics establish the incidence of persistent wound discharge and hypercalcaemia All patients who received an antibiotic loaded calcium sulphate carrier (Stimulan, Biocomposites, Keele, UK) for either confirmed infection, presumed infection or for prophylaxis between July 2015 and July 2020 were included. Stimulan use was at the discretion of the surgeon, and between 10 and 40cc was used. In the absence of a known organism we routinely used 1g vancomycin and 240mg gentamicin per 10 cc of calcium sulphate. Post-operative sensitivities for all organisms cultured were compared to the antibiotics delivered locally. Persistent wound drainage was defined as discharge beyond the third postoperative day. Patients had serum calcium measured if they developed symptoms consistent with hypercalcaemia (Ca >2.6 mmol/L) or the clinical team felt they were at high risk. 189 patients (mean age 66.9 years, mean BMI 28.9, 85 male, 104 female) were included. 11 patients had a native joint septic arthritis, 42 presented with acute PJI and 136 presented with chronic PJI. 133 patients grew an organism, of which 126 were sensitive to the added antibiotics. Of the seven patients with resistant growth five had vancomycin-resistent Enterococcus, one Pseudomonas and one multi-organism growth including coagulase negative Staphylococcus. 40 patients experienced persistent wound discharge, with eight requiring re-operation. All other cases settled with dressing management. 12 patients developed hypercalcaemia (3/64 10cc, 7/117 20cc, 0/2 30cc and 2/6 40cc). The peak calcium reading ranged between the second and twelfth post-operative day. The addition of vancomycin and gentamicin to absorbable calcium sulphate covers the majority of organisms found in culture positive infection in our cohort. It also appears safe, with an acceptable incidence of hypercalcaemia or wound discharge. Further work is required to identify patients at greatest risk of culturing resistant organisms or delayed wound healing.
This study evaluates risk factors influencing fracture characteristics for postoperative periprosthetic femoral fractures (PFFs) around cemented stems in total hip arthroplasty. Data were collected for PFF patients admitted to eight UK centres between 25 May 2006 and 1 March 2020. Radiographs were assessed for Unified Classification System (UCS) grade and AO/OTA type. Statistical comparisons investigated relationships by age, gender, and stem fixation philosophy (polished taper-slip (PTS) vs composite beam (CB)). The effect of multiple variables was estimated using multinomial logistic regression to estimate odds ratios (ORs) with 95% confidence intervals (CIs). Surgical treatment (revision vs fixation) was compared by UCS grade and AO/OTA type.Aims
Methods
The aim of this prospective cohort study was to evaluate the early migration of the TriFit cementless proximally coated tapered femoral stem using radiostereometric analysis (RSA). A total of 21 patients (eight men and 13 women) undergoing primary total hip arthroplasty (THA) for osteoarthritis of the hip were recruited in this study and followed up for two years. Two patients were lost to follow-up. All patients received a TriFit stem and Trinity Cup with a vitamin E-infused highly cross-linked ultra-high molecular weight polyethylene liner. Radiographs for RSA were taken postoperatively and then at three, 12, and 24 months. Oxford Hip Score (OHS), EuroQol five-dimension questionnaire (EQ-5D), and adverse events were reported.Aims
Methods
Accurate orientation of the acetabular component during a total hip replacement is critical for optimising patient function, increasing the longevity of components, and reducing the risk of complications. This study aimed to determine the validity of a novel VR platform (AescularVR) in assessing acetabular component orientation in a simulated model used in surgical training. The AescularVR platform was developed using the HTC Vive® VR system hardware, including wireless trackers attached to the surgical instruments and pelvic sawbone. Following calibration, data on the relative position of both trackers are used to determine the acetabular cup orientation (version and inclination). The acetabular cup was manually implanted across a range of orientations representative of those expected intra-operatively. Simultaneous readings from the Vicon® optical motion capture system were used as the ‘gold standard’ for comparison. Correlation and agreement between these two methods was determined using Bland-Altman plots, Pearson's correlation co-efficient, and linear regression modelling.Abstract
Objectives
Methods
The aim of this study is to report the 30 day COVID-19 related morbidity and mortality of patients assessed as SARS-CoV-2 negative who underwent emergency or urgent orthopaedic surgery in the NHS during the peak of the COVID-19 pandemic. A retrospective, single centre, observational cohort study of all patients undergoing surgery between 17 March 2020 and 3May 2020 was performed. Outcomes were stratified by British Orthopaedic Association COVID-19 Patient Risk Assessment Tool. Patients who were SARS-CoV-2 positive at the time of surgery were excluded.Introduction
Method
Antibiotic loaded absorbable calcium sulphate beads (ALCSB) are an increasingly popular adjunct in the treatment of musculoskeletal infections including osteomyelitis and peri-prosthetic joint infections (PJI). Limited data exist regarding the clinical indications and biochemical outcomes of ALCSB in PJI cases. To determine the proportion of organisms that were sensitive to the gentamicin and vancomycin that we add to the ALCSB as a part of our treatment protocol and to determine the prevalence of postoperative hypercalcaemia when used for treatment of hip and knee DAIR (debridement and implant retention) and revision arthroplasty for PJI.Introduction
Aims
We are a high-volume arthroplasty unit performing over 800 primary THRs annually at an approximate reimbursement of £6.5 million to the Trust. 70% are hybrid and we have been using the Taperfit - Trinity combination (Corin, Cirencester) since March 2016. We aimed to investigate the potential cost-savings and clinical benefits of instrument rationalisation using this system following GIRFT principles. Taperfit (ODEP 10A) is a polished, collarless, double tapered stem available in multiple sizes/offsets. Trinity is a hemispherical porous titanium cementless shell. A prospective audit of implant size was performed for the first 50 cases. Based on these findings, instruments were reduced to a single tray per component based on predicted size, named ‘Corin Hip for the Osteoarthritic Patient’ (CHOP). A further re-audit was performed to confirm correct tray constituent sizes. Financial data were calculated using known TSSU costs of approximately £50 per tray.Introduction
Methods
Late acute prosthetic joint infections (PJI) treated with surgical debridement and implant retention (DAIR) have a high failure rate. The aim of our study was to evaluate treatment outcome in late acute PJIs treated with DAIR versus implant removal. In a large multicenter study, late acute PJIs were retrospectively evaluated. Failure was defined as: PJI related death or the need for prosthesis removal or suppressive antibiotic therapy because of persistent or recurrent signs of infection. Late acute PJI was defined as < 3 weeks of symptoms more than 3 months after the index surgery.Aim
Method
The aim of this study was to determine the stability of a new
short femoral stem compared with a conventional femoral stem in
patients undergoing cementless total hip arthroplasty (THA), in
a prospective randomized controlled trial using radiostereometric
analysis (RSA). A total of 53 patients were randomized to receive cementless
THA with either a short femoral stem (MiniHip, 26 patients, mean
age: 52 years, nine male) or a conventional length femoral stem
(MetaFix, 23 patients, mean age: 53 years, 11 male). All patients
received the same cementless acetabular component. Two-year follow-up
was available on 38 patients. Stability was assessed through migration
and dynamically inducible micromotion. Radiographs for RSA were
taken postoperatively and at three, six, 12, 18, and 24 months.Aims
Patients and Methods
To assess the influence of route of antibiotic administration on patient-reported outcome measures (PROMS) of individuals treated for hip and knee infections in the OVIVA multi-centre randomised controlled trial. This study was designed to determine whether oral antibiotic therapy is non-inferior to intravenous (IV) therapy when given for the first six weeks of treatment for bone and joint infections. Of the 1054 participants recruited from 26 centres, 462 were treated for periprosthetic or native joint infections of the hip or knee. There were 243 participants in the IV antibiotic cohort and 219 in the oral cohort. Functional outcome was determined at baseline through to one year using the Oxford Hip/Knee Score (OHS/OKS) as joint-specific measures (0 the worse and 48 the best). An adjusted quantile regression model was used to compare functional outcome scores.Aim
Method
Advocates of Debridement-Antibiotics-and-Implant-Retention (DAIR) in hip peri-prosthetic joint infection (PJI) argue that a procedure not disturbing a sound prosthesis-bone interface is likely to lead to better survival and functional outcome compared to revision. However, no evidence supports this. This case-control study's aims were to compare outcome of DAIRs for infected 1° total hip arthroplasty (THA) with outcomes following 1° THA and 2-stage revisions of infected 1° THAs. We retrospectively reviewed all DAIRs, performed for confirmed infected 1° THR (DAIR-Group, n=80), in our unit between 1997–2013. Data recorded included patient demographics, medical history, type of surgery and organism identified. Outcome measures included complications, mortality, implant survivorship and functional outcome using the Oxford Hip Score (OHS). Outcome was compared with 2 control groups matched for gender and age; a cohort of 1° THA (1°-THA-Group, n=120) and a cohort of 2-stage revisions for infection (2-Stage-Revision-Group, n=66).Aim
Method
The burden of peri-prosthetic joint infection (PJI) following hip and knee surgery is increasing. Endoprosthetic replacement (EPR) is an option for management of massive bone loss resulting from infection around failed lower limb implants. To determine clinical outcome of EPRs for treatment of PJI around the hip and knee joint.Introduction
Aims
Native hip joint infection can result in hip arthrosis as a complication requiring the need for subsequent arthroplasty. There is little evidence to support single or staged THA. We present the results of patients who have undergone total hip arthroplasty (THA) following hip joint sepsis in our institution. Patients receiving a THA following previous hip joint sepsis between 2003 and 2015 were identified from the operative records database. Further clinical information was collected from the medical records, including timing of infection and surgery, as well as culture results. Functional outcome (Oxford Hip Score, OHS) and patient satisfaction scores (PSS) were recorded.Introduction
Methods
Image-guided intra-articular hip injection of local-anaesthetic and steroid is commonly used in the management of hip pain. It can be used as a diagnostic and/or therapeutic tool and is of low cost (£75). The aim of this study was to assess how often a hip injection has a therapeutic effect. This is a retrospective, consecutive, case series of intra-articular hip injections performed in a tertiary referral hospital over a 2-year period (2013–4). Patients were identified from the radiology department's prospectively entered database. Clinical information, reason for injection and subsequent management was obtained from hospital records. All patients prospectively reported their pain levels in a numeric pain scale diary (out of 10) at various time points; pre-, immediately post-, 1st day-, 2nd day- and 2 weeks- post-injection. Only patients with complete pain scores at all time points were included (n=200, of the 250 injections performed over study period, 80%). The majority of injections were performed for osteoarthritis (OA) treatment (82%). The pain was significantly reduced from a pre-injection score of 7.5 (SD:2) to 5.0 (SD:3) immediately post-injection(p<0.001); only 24 (11%) reported any worsening of pain immediately post-injection. Pain significantly reduced further to 3.8(SD:3) at 2-weeks post-injection (p<0.001). 50% of patients had at least a 3 point drop in reported pain. No improvement was seen in 18 patients and 10 (5%) reported worse pain at 2-weeks compared to pre-injection. Of the OA cohort, 10% have required repeat injections, 45% required no further intervention and 45% underwent or are due for hip replacement. No immediate complications occurred. Intra-articular hip injection reduced pain in 86% of cases and has delayed any further surgical treatment for at least 2 years in over 50% of OA cases. It is hence a cost-effective treatment modality. Further work is necessary to describe factors predicting response.
The value of Debridement-Antibiotics-and-Implant-Retention (DAIR) in prosthetic-joint-infection (PJI) is still a matter of debate as most studies to-date are underpowered with variable end-points. In our, tertiary referral, bone infection unit we consider DAIR to be a suitable option in all PJIs with soundly fixed prostheses, despite chronicity. The aims of this study were to define the long-term outcome following DAIR in hip PJI and identify factors that influence it. This is a retrospective consecutive case series of DAIRs performed between 1997 and 2013. Only infected cases confirmed by established criteria were included. Data recorded included patient demographics, medical history (ASA grade, Charlson and KLICC scores), type of surgery performed (DAIR or DAIR + exchange of modular components) and organism grown. Outcome measures included complications, implant survivorship and functional outcome (Oxford Hip Score, OHS).Introduction
Methods
Debridement, antibiotics and implant retention (DAIR) is a surgical option in the treatment of prosthetic joint infection (PJI). It is thought to be most appropriate in the treatment of early (≤6 weeks post-op) PJI. Most studies to-date reporting on DAIRs in hip PJI have been underpowered by reporting on small cohorts (n= <45), or report on registry data with associated biases and limitations. In our, tertiary referral, bone infection unit we consider DAIR to be a suitable option in all cases of PJI with a soundly fixed prosthesis, with early or late presentation, especially in patients who are too elderly or infirm to undergo major surgery. Aim: To define the 10-year outcome following DAIR in hip PJI and identify factors that influence it. We retrospectively reviewed all DAIRs performed in our unit between 1997 and 2013 for hip PJI. Only infected cases confirmed by histological and microbiological criteria were included. Data recorded included patient demographics and medical history, type of surgery performed (DAIR or DAIR + exchange of modular components), organism identified and type/duration of antibiotic treatment. Outcome measures included complications, mortality rate, implant survivorship and functional outcome. 121 DAIRs were identified with mean age of 71 years (range: 33–97). 67% followed an index procedure of 1° arthroplasty. 53% included exchange of modular components. 60% of DAIRs were for early onset PJI. Isolated staphylococcus was present in 50% of cases and 25% had polymicrobial infection. At follow-up (mean:7 years, range: 0.3 – 18), 83 patients were alive; 5- and 10- year mortality rates were 15% and 35% respectively. 45% had a complication (persistence of infection: 27%, dislocation: 10%) and 40% required further surgery. Twenty hips have been revised to-date (17%). Performing a DAIR and not exchanging the modular components was associated with an almost 3× risk (risk ratio: 2.9) of subsequent implant failure (p=0.04). 10-yr implant survivorship was 80% (95%CI: 70 – 90%). Improved 10-year implant survivorship was associated with DAIR performed for early PJI (85% Vs 68%, p=0.04). Functional outcome will be discussed. DAIR is a particularly valuable option in the treatment of hip PJI, especially in the early post-operative period. Whenever possible, exchange of modular implants should be undertaken, however DAIRs are associated with increased morbidity even in early PJI. Factors that predict success of DAIR in late PJI need to be identified.
The options for the treatment of the young active patient with unicompartmental symptomatic osteoarthritis and pre-existing Anterior Cruciate Ligament (ACL) deficiency are limited. Patients with ACL deficiency and end-stage medial compartment osteoarthritis are usually young and active. The Oxford Unicompartmental Knee Replacement (UKA) is a well established treatment option in the management of symptomatic end-stage medial compartmental osteoarthritis, but a functionally intact ACL is a pre-requisite for its satisfactory outcome. If absent, high failure rates have been reported, primarily due to tibial loosening. Previously, we have reported results on a consecutive series of 15 such patients in whom the ACL was reconstructed and patients underwent a staged or simultaneous UKA. The aim of the current study is to provide an update on the clinical and radiological outcomes of a large, consecutive cohort of patients with ACL reconstruction and UKA for the treatment of end-stage medial compartment osteoarthritis and to evaluate, particularly, the outcome of those patients under 50. This study presents a consecutive series of 52 patients with ACL reconstruction and Oxford UKA performed over the past 10 years (mean follow-up 3.4 years). The mean age was 51 years (range: 36–67). Procedures were either carried out as Simultaneous (n=34) or Staged (n=18). Changes in clinical outcomes were measured using the Oxford Knee Score (OKS), the change in OKS (OKS=Post-op − Pre-op) and the American Knee Society Score (AKSS). Fluoroscopy assisted radiographs were taken at each review to assess for evidence of loosening, radiolucency progression, (if present), and component subsidence.Introduction
Methods
Radiolucencies beneath the tibial component are well recognized in knee arthroplasty; the aetiology and significance are poorly understood. Non-progressive narrow radiolucencies with a sclerotic margin are thought not to be indicative of loosening. Factors which decrease the incidence of radiolucencies include cementless fixation and the use of pulse lavage. Leg/component alignment or BMI do not influence radiolucency. We are not aware of any studies that have looked at the effect of load type on radiolucency. The Oxford domed lateral tibial component was introduced to decrease the bearing dislocation rate that was unacceptably high with the flat tibial tray. However, the introduction of the domed tibial component alters the forces transmitted through the implant-cement-bone interface. As the Oxford UKR uses a fully congruent mobile bearing, the forces transmitted through the interface with a flat tray are compressive, except for the effect of friction. However, with the domed tibial component shear forces are introduced. The aim of this study was to assess the prevalence of radiolucency beneath the previous flat design and the new domed tibial tray. A consecutive series of 248 cemented lateral UKRs (1999–2009) at a single institution were assessed. The first 55 were with a flat tibia and the subsequent 193 with a domed component. One year post-op radiographs were assessed, by two observers, for the presence (full or partial) and distribution of radiolucency. The distribution and thickness of each radiolucency. Cases were excluded for missing or poorly aligned radiographs.Introduction
Patients and methods
Primary mechanical stability is important with uncemented THR because early migration is reduced, leading to more rapid osseointegration between the implant and bone. Such primary mechanical stability is provided by the design features of the device. The aim of this study was to compare the migration patterns of two uncemented hip stems, the Furlong Active and the Furlong HAC stem; the study was designed as a randomised control trial. The implants were the Furlong HAC, which is an established implant with good long term results, and the Furlong Active, which is a modified version of the Furlong HAC designed to minimise stress concentrations between the implant and bone, and thus to improve fixation. The migration of 43 uncemented femoral components for total hip replacement was measured in a randomised control trial using Roentgen Stereophotogrammetric Analysis (RSA) over two years. Twenty-three Furlong HAC and twenty Furlong Active stems were implanted into 43 patients. RSA examinations were carried out post-operatively, and at six months, 12 months and 24 months post-operatively. The patients stood in-front of a purpose made calibration frame which contained accurately positioned radio-opaque markers. From the obtained images, the 3-D positions of the prosthesis and the host bone were reconstructed. Geometrical algorithms were used to identify the components of the implant. These algorithms allowed the femoral component to be studied without the need to attach markers to the prosthesis. The migration was calculated relative to the femoral coordinate system representing the anterior-posterior (A-P), medial-lateral (M-L) and proximal-distal (P-D) directions respectively. Distal migration was termed subsidence.Introduction
Materials and methods
The results of the original mobile bearing Oxford unicompartmental knee replacement (UKR) in the lateral compartment have been disappointing because of high dislocation rates (11%). This original implant used a flat bearing articulation on the tibial tray. To address the issue of dislocation a new implant (domed tibia with biconcave bearing to increase entrapment) was introduced with a modified surgical technique. The aim of this study was to compare the risk of dislocation between a domed and flat lateral UKR. Separate geometric computer models of an Oxford mobile bearing lateral UKR were generated for the two types of articulation between the tibial component and the meniscal bearing: Flat-on-flat (flat) and Concave-on-convex (domed). Each type of mobile bearing was used to investigate three distinct dislocation modes observed clinically: lateral to medial dislocation, with the bearing resting on the tray wall (L-M-Wall); medial to lateral dislocation, out of the joint space (M-L); anterior to posterior dislocation, out of the joint space (A-P). A size C tray and a medium femoral component and bearing were used in all models. The femoral component, tibial tray and bearing were first aligned in a neutral position. For each dislocation the tibial tray was restrained in all degrees of freedom. The femoral component was restrained from moving in the anterior-posterior directions and in the medial-lateral directions. The femoral component was also restrained from rotating about the anterior-posterior, medial-lateral and superior-inferior directions. This meant that the femoral component was only able to move in the superior-inferior direction. Different bearing sizes were inserted into the model and the effect that moving the femoral component medially and laterally had on the amount of distraction required to cause bearing dislocation was investigated.Introduction
Methods
Unicompartmental Knee Replacement (UKR) is an appealing alternative to Total Knee Replacement (TKR) when the patient has isolated compartment osteoarthritis (OA). A common observation post-operatively is radiolucency between the tibial tray wall and the bone. In addition, some patients complain of persistent pain following implantation with a UKR; this may be related to elevated bone strains in the tibia. The aim of this study was to investigate the mechanical environment of the tibia bone adjacent to the tray wall, following UKR, to determine whether this region of bone resorbs, and how altering the mechanical environment affects tibia strains. A finite element (FE) model of a cadaver tibia implanted with an Oxford UKR was used in this study, based on a validated model. A single static load, measured in-vivo during a step-up activity was used. There was a 1 mm layer of cement surrounding the keel in the cemented UKR, and the cement filled the cement pocket. In accordance with the operating procedure, no cement was used between the tray wall and bone. For the cementless UKR a layer of titanium filled the cement pocket. An intact tibia was used to compare to the cemented and cementless UKR implanted tibiae. The tibia was sectioned by the tray wall, defining the radiolucency zone (parallel to the vertical tray wall, 2 mm wide with a volume of 782.5 mm3), corresponding to the region on screened x-rays where radiolucencies are observed. Contact mechanics algorithms were used between all contacting surfaces; bonded contact was also introduced between the tray wall and adjacent bone, simulating a mechanical tie between them. Strain energy density (SED), was compared between the intact and implanted tibia for the radiolucency zone. Equivalent strains were compared on the proximal tibia between the intact and implanted tibia models. Forty patients (20 cemented, 20 cementless) who had undergone UKR were randomly selected from a database, and assessed for radiolucency.Introduction
Materials and methods
Total knee arthroplasty (TKA) accounts for 84% of all knee replacement surgery in the UK (NJR 2009) despite published epidemiological data showing that single compartment disease is most prevalent. We investigated this incompatibility further by describing the compartmental pattern and stage of cartilage loss of all patients with osteoarthritis (OA) presenting to a specialist knee clinic over one year. All new primary referrals in a calendar year by local General Practitioners to knee clinic at a United Kingdom Hospital were assessed. Tertiary referrals and second opinions were excluded. The final diagnosis after all imaging was recorded and tabulated. The standing AP, lateral and skyline radiographs of all cases of arthritis were scored to assess the pattern of disease.Introduction
Methods
To investigate the linear penetration rate of the polyethylene bearing in unicompartmental knee arthroplasty at twenty years. The Phase 1 Oxford medial UKR was introduced in 1978 as a design against wear, with a fully congruous articulation. In 1987 the Phase 2 implant was introduced with new instrumentation and changes to the bearing shape. We have previously shown a linear penetration rate (LPR) of 0.02 mm/year at ten years in Phase 2, but that higher penetration rates can be seen with impingement. The aim of this study was to determine the 20 year in-vivo LPR of the Oxford UKR, using Roentgen Stereophotogrammetric Analysis (RSA).Purpose of study
Introduction
To assess the incidence of radiolucency in cemented and cementless Oxford unicompartmental knee replacement at two years. Most unicompartmental knee replacements (UKRs) employ cement for fixation of the prosthetic components. The information in the literature about the relative merits of cemented and cementless UKR is contradictory, with some favouring cementless fixation and others favouring cemented fixation. In addition, there is concern about the radiolucency that frequently develops beneath the tibial component with cemented fixation. The exact cause of the occurrence of radiolucency is unknown but it has been hypothesised that it may suggest suboptimal fixation.Purpose of Study
Introduction
A retrospective review of all patients transferred by helicopter ambulance to the Great Western Hospital over a 20-month period between January 2003 and September 2004 was undertaken to establish the case-mix of patients (trauma and non-trauma) transferred and the outcome of their admission and length of hospital stay. Details of all Helicopter Emergency Ambulance Service (HEAS) transfers to this unit in the study time period were obtained from the three HEAS providers in the area and case notes for all patients (where available) were reviewed.Background
Methods
90% of lateral compartments were normal and none had full thickness cartilage loss. However 10% showed high signal in the tibial plateau. There was a highly reproducible pattern of osteophyte formation; 94% posteromedial and posterolateral aspect of medial femoral condyle; 90% medial tibial; 80% medial femoral and 84% lateral intercondylar notch.
100% of medial compartments showed full thickness anteromedial loss with preservation of the posteromedial cartilage. When present, the meniscus was extruded in 96% of cases. 90% of lateral compartments were normal and none had full thickness cartilage loss. However 10% showed high signal in the tibial plateau. There was a highly reproducible pattern of osteophyte formation; 94% posteromedial and posterolateral aspect of medial femoral condyle; 90% medial tibial; 80% medial femoral and 84% lateral intercondylar notch.