Advertisement for orthosearch.org.uk
Results 1 - 100 of 994
Results per page:
The Bone & Joint Journal
Vol. 104-B, Issue 10 | Pages 1118 - 1125
4 Oct 2022
Suda Y Hiranaka T Kamenaga T Koide M Fujishiro T Okamoto K Matsumoto T

Aims. A fracture of the medial tibial plateau is a serious complication of Oxford mobile-bearing unicompartmental knee arthroplasty (OUKA). The risk of these fractures is reportedly lower when using components with a longer keel-cortex distance (KCDs). The aim of this study was to examine how slight varus placement of the tibial component might affect the KCDs, and the rate of tibial plateau fracture, in a clinical setting. Methods. This retrospective study included 255 patients who underwent 305 OUKAs with cementless tibial components. There were 52 males and 203 females. Their mean age was 73.1 years (47 to 91), and the mean follow-up was 1.9 years (1.0 to 2.0). In 217 knees in 187 patients in the conventional group, tibial cuts were made orthogonally to the tibial axis. The varus group included 88 knees in 68 patients, and tibial cuts were made slightly varus using a new osteotomy guide. Anterior and posterior KCDs and the origins of fracture lines were assessed using 3D CT scans one week postoperatively. The KCDs and rate of fracture were compared between the two groups. Results. Medial tibial fractures occurred after surgery in 15 patients (15 OUKAs) in the conventional group, but only one patient (one OUKA) had a tibial fracture after surgery in the varus group. This difference was significant (6.9% vs 1.1%; p = 0.029). The mean posterior KCD was significantly shorter in the conventional group (5.0 mm (SD 1.7)) than in the varus group (6.1 mm (SD 2.1); p = 0.002). Conclusion. In OUKA, the distance between the keel and posterior tibial cortex was longer in our patients with slight varus alignment of the tibial component, which seems to decrease the risk of postoperative tibial fracture. Cite this article: Bone Joint J 2022;104-B(10):1118–1125


Bone & Joint Research
Vol. 5, Issue 4 | Pages 116 - 121
1 Apr 2016
Leow JM Clement ND Tawonsawatruk T Simpson CJ Simpson AHRW

Objectives. The radiographic union score for tibial (RUST) fractures was developed by Whelan et al to assess the healing of tibial fractures following intramedullary nailing. In the current study, the repeatability and reliability of the RUST score was evaluated in an independent centre (a) using the original description, (b) after further interpretation of the description of the score, and (c) with the immediate post-operative radiograph available for comparison. Methods. A total of 15 radiographs of tibial shaft fractures treated by intramedullary nailing (IM) were scored by three observers using the RUST system. Following discussion on how the criteria of the RUST system should be implemented, 45 sets (i.e. AP and lateral) of radiographs of IM nailed tibial fractures were scored by five observers. Finally, these 45 sets of radiographs were rescored with the baseline post-operative radiograph available for comparison. Results. The initial intraclass correlation (ICC) on the first 15 sets of radiographs was 0.67 (95% CI 0.63 to 0.71). However, the original description was being interpreted in different ways. After agreeing on the interpretation, the ICC on the second cohort improved to 0.75. The ICC improved even further to 0.79, when the baseline post-operative radiographs were available for comparison. Conclusion. This study demonstrates that the RUST scoring system is a reliable and repeatable outcome measure for assessing tibial fracture healing. Further improvement in the reliability of the scoring system can be obtained if the radiographs are compared with the baseline post-operative radiographs. Cite this article: Mr J.M. Leow. The radiographic union scale in tibial (RUST) fractures: Reliability of the outcome measure at an independent centre. Bone Joint Res 2016;5:116–121. DOI: 10.1302/2046-3758.54.2000628


The Bone & Joint Journal
Vol. 103-B, Issue 6 | Pages 1160 - 1167
1 Jun 2021
Smith JRA Fox CE Wright TC Khan U Clarke AM Monsell FP

Aims. Open tibial fractures are limb-threatening injuries. While limb loss is rare in children, deep infection and nonunion rates of up to 15% and 8% are reported, respectively. We manage these injuries in a similar manner to those in adults, with a combined orthoplastic approach, often involving the use of vascularised free flaps. We report the orthopaedic and plastic surgical outcomes of a consecutive series of patients over a five-year period, which includes the largest cohort of free flaps for trauma in children to date. Methods. Data were extracted from medical records and databases for patients with an open tibial fracture aged < 16 years who presented between 1 May 2014 and 30 April 2019. Patients who were transferred from elsewhere were excluded, yielding 44 open fractures in 43 patients, with a minimum follow-up of one year. Management was reviewed from the time of injury to discharge. Primary outcome measures were the rate of deep infection, time to union, and the Modified Enneking score. Results. The mean age of the patients was 9.9 years (2.8 to 15.8), and 28 were male (64%). A total of 30 fractures (68%) involved a motor vehicle collision, and 34 (77%) were classified as Gustilo Anderson (GA) grade 3B. There were 17 (50%) GA grade 3B fractures, which were treated with a definitive hexapod fixator, and 33 fractures (75%) were treated with a free flap, of which 30 (91%) were scapular/parascapular or anterolateral thigh (ALT) flaps. All fractures united at a median of 12.3 weeks (interquartile range (IQR) 9.6 to 18.1), with increasing age being significantly associated with a longer time to union (p = 0.005). There were no deep infections, one superficial wound infection, and the use of 20 fixators (20%) was associated with a pin site infection. The median Enneking score was 90% (IQR 87.5% to 95%). Three patients had a bony complication requiring further surgery. There were no flap failures, and eight patients underwent further plastic surgery. Conclusion. The timely and comprehensive orthoplastic care of open tibial fractures in this series of patiemts aged < 16 years resulted in 100% union and 0% deep infection, with excellent patient-reported functional outcomes. Cite this article: Bone Joint J 2021;103-B(6):1160–1167


Bone & Joint Open
Vol. 3, Issue 12 | Pages 941 - 952
23 Dec 2022
Shah A Judge A Griffin XL

Aims. Several studies have reported that patients presenting during the evening or weekend have poorer quality healthcare. Our objective was to examine how timely surgery for patients with severe open tibial fracture varies by day and time of presentation and by type of hospital. This cohort study included patients with severe open tibial fractures from the Trauma Audit and Research Network (TARN). Methods. Provision of prompt surgery (debridement within 12 hours and soft-tissue coverage in 72 hours) was examined, using multivariate logistic regression to derive adjusted risk ratios (RRs). Time was categorized into three eight-hour intervals for each day of the week. The models were adjusted for treatment in a major trauma centre (MTC), sex, age, year of presentation, injury severity score, injury mechanism, and number of operations each patient received. Results. We studied 8,258 patients from 175 hospitals. Patients presenting during the day (08:00 to 15:59; risk ratio (RR) 1.11, 95% confidence interval (CI) 1.02 to 1.20) were more likely to receive debridement within 12 hours, and patients presenting at night (16:00 to 23:59; RR 0.56, 95% CI 0.51 to 0.62) were less likely to achieve the target; triage to a MTC had no effect. Day of presentation was associated with soft-tissue coverage within 72 hours; patients presenting on a Thursday or Friday being less likely to receive this surgery within 72 hours (Thursday RR 0.88, 95% CI 0.81 to 0.97; Friday RR 0.89, 95% CI 0.81 to 0.98), and the standard less likely to be achieved for those treated in ‘non-MTC’ hospitals (RR 0.76, 95% CI 0.70 to 0.82). Conclusion. Variations in care were observed for timely surgery for severe open tibial fractures with debridement surgery affected by time of presentation and soft-tissue coverage affected by day of presentation and type of hospital. The variation is unwarranted and highlights that there are opportunities to substantially improve the delivery and quality of care for patients with severe open tibial fracture. Cite this article: Bone Jt Open 2022;3(12):941–952


The Bone & Joint Journal
Vol. 102-B, Issue 1 | Pages 17 - 25
1 Jan 2020
Trickett RW Mudge E Price P Pallister I

Aims. The aim of this study was to develop a psychometrically sound measure of recovery for use in patients who have suffered an open tibial fracture. Methods. An initial pool of 109 items was generated from previous qualitative data relating to recovery following an open tibial fracture. These items were field tested in a cohort of patients recovering from an open tibial fracture. They were asked to comment on the content of the items and structure of the scale. Reduction in the number of items led to a refined scale tested in a larger cohort of patients. Principal components analysis permitted further reduction and the development of a definitive scale. Internal consistency, test-retest reliability, and responsiveness were assessed for the retained items. Results. The initial scale was completed by 35 patients who were recovering from an open tibial fracture. Subjective and objective analysis permitted removal of poorly performing items and the addition of items suggested by patients. The refined scale consisted of 50 Likert scaled items and eight additional items. It was completed on 228 occasions by a different cohort of 204 patients with an open tibial fracture recruited from several UK orthoplastic tertiary referral centres. There were eight underlying components with tangible real-life meaning, which were retained as sub-scales represented by ten Likert scaled and eight non-Likert items. Internal consistency and test-retest reliability were good to excellent. Conclusion. The Wales Lower Limb Trauma Recovery (WaLLTR) Scale is the first tool to be developed from patient data with the potential to assess recovery following an open tibial fracture. Cite this article: Bone Joint J 2020;102-B(1):17–25


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_5 | Pages 12 - 12
23 Apr 2024
Jido JT Al-Wizni A Rodham P Taylor DM Kanakaris N Harwood P
Full Access

Introduction. Management of complex fractures poses a significant challenge. Evolving research and changes to national guidelines suggest better outcomes are achieved by transfer to specialist centres. The development of Major Trauma Networks was accompanied by relevant financial arrangements. These do not apply to patients with closed fractures referred for specialist treatment by similar pathways. Despite a surge in cases transferred for care, there is little information available regarding the financial impact on receiving institutions. Materials & Methods. This retrospective study examines data from a Level 1 trauma centre. Patients were identified from our electronic referral system, used for all referrals. Transferred adult patients, undergoing definitive treatment of acute isolated closed tibial fractures, were included for a 2-year period. Data was collected using our clinical and Patient Level Information and Costing (PLICS) systems including coding, demographics, treatment, length of stay (LOS), total operative time, number of operations, direct healthcare costs, and NHS reimbursements. Results. 104 patients were identified, 23 patients were treated by internal fixation and 81 with circular frames. Patients required a median of 190 minutes of total operative time and 6 days of hospital stay at a median cost of £16,233 each, median reimbursement was £10,625. The total cost of treatment for all 104 patients was £2,205,611 and total reimbursement was £1,391463, the median deficit per patient being £5825. The overall deficit over the 2 years was £814,148. Conclusions. This study reveals a considerable economic burden associated with treating complex tibial fractures. It should be emphasised that these do not include patients referred for fracture-related infection or non-union, who may also incur similar deficits in recovered costs. These findings emphasise the importance of understanding and addressing the financial implications of managing tertiary referral orthopaedic trauma patients to ensure efficient and sustainable resource allocation


Bone & Joint Open
Vol. 2, Issue 1 | Pages 22 - 32
4 Jan 2021
Sprague S Heels-Ansdell D Bzovsky S Zdero R Bhandari M Swiontkowski M Tornetta P Sanders D Schemitsch E

Aims. Using tibial shaft fracture participants from a large, multicentre randomized controlled trial, we investigated if patient and surgical factors were associated with health-related quality of life (HRQoL) at one year post-surgery. Methods. The Study to Prospectively Evaluate Reamed Intramedullary Nails in Patients with Tibial Fractures (SPRINT) trial examined adults with an open or closed tibial shaft fracture who were treated with either reamed or unreamed intramedullary nails. HRQoL was assessed at hospital discharge (for pre-injury level) and at 12 months post-fracture using the Short Musculoskeletal Functional Assessment (SMFA) Dysfunction, SMFA Bother, 36-Item Short Form 36 (SF-36) Physical, and SF-36 Mental Component scores. We used multiple linear regression analysis to determine if baseline and surgical factors, as well as post-intervention procedures within one year of fracture, were associated with these HRQoL outcomes. Significance was set at p < 0.01. We hypothesize that, irrespective of the four measures used, prognosis is guided by both modifiable and non-modifiable factors and that patients do not return to their pre-injury level of function, nor HRQoL. Results. For patient and surgical factors, only pre-injury quality of life and isolated fracture showed a statistical effect on all four HRQoL outcomes, while high-energy injury mechanism, smoking, and race or ethnicity, demonstrated statistical significance for three of the four HRQoL outcomes. Patients who did not require reoperation in response to infection, the need for bone grafts, and/or the need for implant exchanges had statistically superior HRQoL outcomes than those who did require intervention within one year after initial tibial fracture nailing. Conclusion. We identified several baseline patient factors, surgical factors, and post-intervention procedures within one year after intramedullary nailing of a tibial shaft fracture that may influence a patient’s HRQoL. Cite this article: Bone Jt Open 2021;2(1):22–32


The Bone & Joint Journal
Vol. 100-B, Issue 9 | Pages 1227 - 1233
1 Sep 2018
Gitajn IL Titus AJ Tosteson AN Sprague S Jeray K Petrisor B Swiontkowski M Bhandari M Slobogean G

Aims. The aims of this study were to quantify health state utility values (HSUVs) after a tibial fracture, investigate the effect of complications, to determine the trajectory in HSUVs that result in these differences and to quantify the quality-adjusted life years (QALYs) experienced by patients. Patients and Methods. This is an analysis of 2138 tibial fractures enrolled in the Fluid Lavage of Open Wounds (FLOW) and Study to Prospectively Evaluate Reamed Intramedullary Nails in Patients with Tibial Fractures (SPRINT) trials. Patients returned for follow-up at two and six weeks and three, six, nine and 12 months. Short-Form Six-Dimension (SF-6D) values were calculated and used to calculate QALYs. Results. Compared with those who did not have a complication, those with a complication treated either nonoperatively or operatively had lower HSUVs at all times after two weeks. The HSUVs improved in all patients with the passage of time. However, they did not return to the remembered baseline preinjury values nor to US age-adjusted normal values by 12 months after the injury. Conclusion. While the acute fracture and complications may have resolved clinically, the detrimental effect on a patient’s quality of life persists up to 12 months after the injury. Cite this article: Bone Joint J 2018;100-B:1227–33


The Bone & Joint Journal
Vol. 101-B, Issue 8 | Pages 1002 - 1008
1 Aug 2019
Al-Hourani K Stoddart M Khan U Riddick A Kelly M

Aims. Type IIIB open tibial fractures are devastating high-energy injuries. At initial debridement, the surgeon will often be faced with large bone fragments with tenuous, if any, soft-tissue attachments. Conventionally these are discarded to avoid infection. We aimed to determine if orthoplastic reconstruction using mechanically relevant devitalized bone (ORDB) was associated with an increased infection rate in type IIIB open tibial shaft fractures. Patient and Methods. This was a consecutive cohort study of 113 patients, who had sustained type IIIB fractures of the tibia following blunt trauma, over a four-year period in a level 1 trauma centre. The median age was 44.3 years (interquartile range (IQR) 28.1 to 65.9) with a median follow-up of 1.7 years (IQR 1.2 to 2.1). There were 73 male patients and 40 female patients. The primary outcome measures were deep infection rate and number of operations. The secondary outcomes were nonunion and flap failure. Results. In all, 44 patients had ORDB as part of their reconstruction, with the remaining 69 not requiring it. Eight out of 113 patients (7.1%) developed a deep infection (ORDB 1/44, non-ORDB 7/69). The median number of operations was two. A total of 16/242 complication-related reoperations were undertaken (6.6%), with 2/16 (12.5%) occurring in the ORDB group. Conclusion. In the setting of an effective orthoplastic approach to type IIIB open diaphyseal tibial fractures, using mechanically relevant debrided devitalized bone fragments in the definitive reconstruction appears to be safe. Cite this article: Bone Joint J 2019;101-B:1002–1008


Bone & Joint Research
Vol. 13, Issue 3 | Pages 127 - 135
22 Mar 2024
Puetzler J Vallejo Diaz A Gosheger G Schulze M Arens D Zeiter S Siverino C Richards RG Moriarty TF

Aims. Fracture-related infection (FRI) is commonly classified based on the time of onset of symptoms. Early infections (< two weeks) are treated with debridement, antibiotics, and implant retention (DAIR). For late infections (> ten weeks), guidelines recommend implant removal due to tolerant biofilms. For delayed infections (two to ten weeks), recommendations are unclear. In this study we compared infection clearance and bone healing in early and delayed FRI treated with DAIR in a rabbit model. Methods. Staphylococcus aureus was inoculated into a humeral osteotomy in 17 rabbits after plate osteosynthesis. Infection developed for one week (early group, n = 6) or four weeks (delayed group, n = 6) before DAIR (systemic antibiotics: two weeks, nafcillin + rifampin; four weeks, levofloxacin + rifampin). A control group (n = 5) received revision surgery after four weeks without antibiotics. Bacteriology of humerus, soft-tissue, and implants was performed seven weeks after revision surgery. Bone healing was assessed using a modified radiological union scale in tibial fractures (mRUST). Results. Greater bacterial burden in the early group compared to the delayed and control groups at revision surgery indicates a retraction of the infection from one to four weeks. Infection was cleared in all animals in the early and delayed groups at euthanasia, but not in the control group. Osteotomies healed in the early group, but bone healing was significantly compromised in the delayed and control groups. Conclusion. The duration of the infection from one to four weeks does not impact the success of infection clearance in this model. Bone healing, however, is impaired as the duration of the infection increases. Cite this article: Bone Joint Res 2024;13(3):127–135


The Bone & Joint Journal
Vol. 95-B, Issue 1 | Pages 101 - 105
1 Jan 2013
Penn-Barwell JG Bennett PM Fries CA Kendrew JM Midwinter MJ Rickard RF

The aim of this study was to report the pattern of severe open diaphyseal tibial fractures sustained by military personnel, and their orthopaedic–plastic surgical management.The United Kingdom Military Trauma Registry was searched for all such fractures sustained between 2006 and 2010. Data were gathered on demographics, injury, management and preliminary outcome, with 49 patients with 57 severe open tibial fractures identified for in-depth study. The median total number of orthopaedic and plastic surgical procedures per limb was three (2 to 8). Follow-up for 12 months was complete in 52 tibiae (91%), and half the fractures (n = 26) either had united or in the opinion of the treating surgeon were progressing towards union. The relationship between healing without further intervention was examined for multiple variables. Neither the New Injury Severity Score, the method of internal fixation, the requirement for vascularised soft-tissue cover nor the degree of bone loss was associated with poor bony healing. Infection occurred in 12 of 52 tibiae (23%) and was associated with poor bony healing (p = 0.008). This series characterises the complex orthopaedic–plastic surgical management of severe open tibial fractures sustained in combat and defines the importance of aggressive prevention of infection. Cite this article: Bone Joint J 2013;95-B:101–5


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 7 | Pages 989 - 993
1 Jul 2012
Monsell FP Howells NR Lawniczak D Jeffcote B Mitchell SR

Between 2005 and 2010 ten consecutive children with high-energy open diaphyseal tibial fractures were treated by early reduction and application of a programmable circular external fixator. They were all male with a mean age of 11.5 years (5.2 to 15.4), and they were followed for a mean of 34.5 months (6 to 77). Full weight-bearing was allowed immediately post-operatively. The mean time from application to removal of the frame was 16 weeks (12 to 21). The mean deformity following removal of the frame was 0.15° (0° to 1.5°) of coronal angulation, 0.2° (0° to 2°) sagittal angulation, 1.1 mm (0 to 10) coronal translation, and 0.5 mm (0 to 2) sagittal translation. All patients achieved consolidated bony union and satisfactory wound healing. There were no cases of delayed or nonunion, compartment syndrome or neurovascular injury. Four patients had a mild superficial pin site infection; all settled with a single course of oral antibiotics. No patient had a deep infection or re-fracture following removal of the frame. The time to union was comparable with, or better than, other published methods of stabilisation for these injuries. The stable fixator configuration not only facilitates management of the accompanying soft-tissue injury but enables anatomical post-injury alignment, which is important in view of the limited remodelling potential of the tibia in children aged > ten years. Where appropriate expertise exists, we recommend this technique for the management of high-energy open tibial fractures in children


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 3 | Pages 351 - 357
1 Mar 2006
Naique SB Pearse M Nanchahal J

Although it is widely accepted that grade IIIB open tibial fractures require combined specialised orthopaedic and plastic surgery, the majority of patients in the UK initially present to local hospitals without access to specialised trauma facilities. The aim of this study was to compare the outcome of patients presenting directly to a specialist centre (primary group) with that of patients initially managed at local centres (tertiary group). We reviewed 73 consecutive grade IIIB open tibial shaft fractures with a mean follow-up of 14 months (8 to 48). There were 26 fractures in the primary and 47 in the tertiary group. The initial skeletal fixation required revision in 22 (47%) of the tertiary patients. Although there was no statistically-significant relationship between flap timing and flap failure, all the failures (6 of 63; 9.5%) occurred in the tertiary group. The overall mean time to union of 28 weeks was not influenced by the type of skeletal fixation. Deep infection occurred in 8.5% of patients, but there were no persistently infected fractures. The infection rate was not increased in those patients debrided more than six hours after injury. The limb salvage rate was 93%. The mean limb functional score was 74% of that of the normal limb. At review, 67% of patients had returned to employment, with a further 10% considering a return after rehabilitation. The times to union, infection rates and Enneking limb reconstruction scores were not statistically different between the primary and tertiary groups. The increased complications and revision surgery encountered in the tertiary group suggest that severe open tibial fractures should be referred directly to specialist centres for simultaneous combined management by orthopaedic and plastic surgeons


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_10 | Pages 38 - 38
1 Jun 2023
Hrycaiczuk A Biddlestone J Rooney B Mahendra A Fairbairn N Jamal B
Full Access

Introduction. A significant burden of disease exists with respect to critical sized bone defects; outcomes are unpredictable and often poor. There is no absolute agreement on what constitutes a “critically-sized” bone defect however it is widely considered as one that would not heal spontaneously despite surgical stabilisation, thus requiring re-operation. The aetiology of such defects is varied. High-energy trauma with soft tissue loss and periosteal stripping, bone infection and tumour resection all require extensive debridement and the critical-sized defects generated require careful consideration and strategic management. Current management practice of these defects lacks consensus. Existing literature tells us that tibial defects 25mm or great have a poor natural history; however, there is no universally agreed management strategy and there remains a significant evidence gap. Drawing its origins from musculoskeletal oncology, the Capanna technique describes a hybrid mode of reconstruction. Mass allograft is combined with a vascularised fibula autograft, allowing the patient to benefit from the favourable characteristics of two popular reconstruction techniques. Allograft confers initial mechanical stability with autograft contributing osteogenic, inductive and conductive capacity to encourage union. Secondarily its inherent vascularity affords the construct the ability to withstand deleterious effects of stressors such as infection that may threaten union. The strengths of this hybrid construct we believe can be used within the context of critical-sized bone defects within tibial trauma to the same success as seen within tumour reconstruction. Methodology. Utilising the Capanna technique in trauma requires modification to the original procedure. In tumour surgery pre-operative cross-sectional imaging is a pre-requisite. This allows surgeons to assess margins, plan resections and order allograft to match the defect. In trauma this is not possible. We therefore propose a two-stage approach to address critical-sized tibial defects in open fractures. After initial debridement, external fixation and soft tissue management via a combined orthoplastics approach, CT imaging is performed to assess the defect geometry, with a polymethylmethacrylate (PMMA) spacer placed at index procedure to maintain soft tissue tension, alignment and deliver local antibiotics. Once comfortable that no further debridement is required and the risk of infection is appropriate then 3D printing technology can be used to mill custom jigs. Appropriate tibial allograft is ordered based on CT measurements. A pedicled fibula graft is raised through a lateral approach. The peroneal vessels are mobilised to the tibioperoneal trunk and passed medially into the bone void. The cadaveric bone is prepared using the custom jig on the back table and posterolateral troughs made to allow insertion of the fibula, permitting some hypertrophic expansion. A separate medial incision allows attachment of the custom jig to host tibia allowing for reciprocal cuts to match the allograft. The fibula is implanted into the allograft, ensuring nil tension on the pedicle and, after docking the graft, the hybrid construct is secured with multi-planar locking plates to provide rotational stability. The medial window allows plate placement safely away from the vascular pedicle. Results. We present a 50-year-old healthy male with a Gustilo & Anderson 3B proximal tibial fracture, open posteromedially with associated shear fragment, treated using the Capanna technique. Presenting following a fall climbing additional injuries included a closed ipsilateral calcaneal and medial malleolar fracture, both treated operatively. Our patient underwent reconstruction of his tibia with the above staged technique. Two debridements were carried out due to a 48-hour delay in presentation due to remote geographical location of recovery. Debridements were carried out in accordance with BOAST guidelines; a spanning knee external fixator applied and a small area of skin loss on the proximal medial calf reconstructed with a split thickness skin graft. A revision cement spacer was inserted into the metaphyseal defect measuring 84mm. At definitive surgery the external fixator was removed and graft fixation was extended to include the intra-articular fragments. No intra-operative complications were encountered during surgeries. The patient returned to theatre on day 13 with a medial sided haematoma. 20ml of haemoserous fluid was evacuated, a DAIR procedure performed and antibiotic-loaded bioceramics applied locally. Samples grew Staphylococcus aureus and antibiotic treatment was rationalised to Co-Trimoxazole 960mg BD and Rifampicin 450mg BD. The patient has completed a six-week course of Rifampicin and continues on suppressive Co-Trimoxazole monotherapy until planned metalwork removal. There is no evidence of ongoing active infection and radiological evidence of early union. The patient is independently walking four miles to the gym daily and we believe, thus far, despite accepted complications, we have demonstrated a relative early success. Conclusions. A variety of techniques exist for the management of critical-sized bone defects within the tibia. All of these come with a variety of drawbacks and limitations. Whilst acceptance of a limb length discrepancy is one option, intercalary defects of greater than 5 to 7cm typically require reconstruction. In patients in whom fine wire fixators and distraction osteogenesis are deemed inappropriate, or are unwilling to tolerate the frequent re-operations and potential donor site morbidity of the Masqualet technique, the Capanna technique offers a novel solution. Through using tibial allograft to address the size mismatch between vascularised fibula and tibia, the possible complication of fatigue fracture of an isolated fibula autograft is potentially avoidable in patients who have high functional demands. The Capanna technique has demonstrated satisfactory results within tumour reconstruction. Papers report that by combining the structural strength of allograft with the osteoconductive and osteoinductive properties of a vascularised autograft that limb salvage rates of greater than 80% and union rates of greater than 90% are achievable. If these results can indeed be replicated in the management of critical-sized bone defects in tibial trauma we potentially have a treatment strategy that can excel over the more widely practiced current techniques


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXIX | Pages 258 - 258
1 Sep 2012
Stammers J Williams D Berber O Abidin SZ Hunter J Leckenby J Vesely M Nielsen D
Full Access

Aims. The BOA/BAPRAS guidelines for the management of open tibial fractures (2009) recommend early senior combined orthoplastics input and appropriate facilities to manage a high caseload. St Georges Hospital is one of four London Trauma Centres fulfilling these criteria. Our aim is to determine whether becoming a trauma centre has affected the management of patients with open tibial fractures. Methods. Data were obtained prospectively on consecutive open tibial fractures during two 8 month periods: before and after becoming a Major Trauma Centre (May 2009–Dec 2009 and April 2010–Oct 2010 respectively). Data on patient pathway including, admitting hospital, length of stay, timing and number of operations were recorded. Results. 29 open tibial fractures were admitted during the 8 months after designation as a major trauma centre compared to 15 before. 72% of patients came directly, or as A&E hot transfers (previously 60%). Of the eight tertiary transfers, six were from hospitals outside the South West Trauma Network. The time to transfer patients initially admitted to local orthopaedic departments has fallen from 8.6 to 1.6 days. Despite this improvement as a trauma centre, these patients remained in hospital longer (16.3 vs 14.9) and had more operations (3.7 vs 2.6) than direct admissions. As a trauma centre there were improvements in time to definitive skeletal stabilisation (4.7 to 2.2), skin coverage (8.3 to 3.7 days), average number of operations (4.2 to 2.3) and average length of hospital admission fell from 23 to 16 days. Conclusions. The volume and management of open tibial fractures has been directly affected by introduction of a trauma centre within the London Trauma Network. Implementation of BOAST guidelines has resulted in improved management of open lower limb fractures independent of fracture grade. Our data strongly support the continuing development of trauma networks


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_1 | Pages 100 - 100
1 Jan 2013
Malhotra K Pai S Radcliffe G
Full Access

Aims. Compartment syndrome (CS) is a well-recognised, serious complication of long bone fractures. The association between CS and tibial shaft fractures is well documented in adult patients and in children with open or high velocity trauma. There is, however, little literature on the risk of developing CS in children with closed tibial fractures. In a number of units these children are routinely admitted for elevation and monitoring for CS. We audited our experience of managing paediatric tibial fractures to ascertain whether it may be safe to discharge a sub-group of these children. Methods. We audited all children up to the age of 12 years admitted to our hospital over a 5 year period. We reviewed radiographs and clinical notes to determine fracture pattern, modality of treatment, and complications. Results. We audited 159 tibial fractures. The mean age was 5.8 years (1–12 years), 95 boys, 64 girls. 105 (66%) closed fractures were conservatively managed: 87 of these were diaphyseal and 20 involved both tibia and fibula. Of the conservatively managed fractures, 89 (85%) were minimally displaced (< 5 degrees varus/valgus/anterior angulation, < 5 degrees rotation, < 5mm shortening, no posterior angulation). In the conservatively managed group there were 3 cases of angulation in cast, managed with wedging. There were no other complications and no cases of compartment syndrome. Conclusion. Of the 105 closed tibial fractures we managed conservatively, most were minimally displaced, diaphyseal, tibia-only fractures. No patient developed compartment syndrome. Based on our experience we suggest that children with closed, minimally displaced tibial fractures do not require admission for monitoring of CS and may go home in a plaster-slab with early fracture clinic follow-up providing suitable supervision is in place, pain is controlled, and they are able to mobilise safely


The Journal of Bone & Joint Surgery British Volume
Vol. 77-B, Issue 3 | Pages 473 - 478
1 May 1995
Eyres K Kanis J

We evaluated changes in bone mineral density (BMD) after tibial fractures, both at the site of fracture and at adjacent sites, using dual-energy X-ray absorptiometry. Five patients were studied prospectively for six months after fractures of the midshaft treated by intramedullary nailing or the application of an external fixator. We also reviewed 21 adult and 10 children who had sustained fractures of the tibia at least five years previously, comparing BMD in the injured limb with that in the non-injured limb and in a control group of 10 normal subjects. We found a significant fall in BMD distal to a tibial fracture; this was evident at one month, fell to approximately 50% of normal at three months and persisted at six months. We found no significant improvement with weight-bearing. Review at 5 to 11 years after adult midshaft fractures showed persistent bone loss in the distal tibia (46.5 +/- 9.8% of control values), but persisting sclerosis at old fracture sites (172 +/- 38% of control values). In contrast, we found no significant differences in BMD between the injured and control limb after fractures sustained in childhood either at the fracture site or in the distal segment. We conclude that, in adults, tibial fractures are associated with definite and persistent post-traumatic loss of distal BMD


The Bone & Joint Journal
Vol. 99-B, Issue 11 | Pages 1526 - 1532
1 Nov 2017
Tarride JE Hopkins RB Blackhouse G Burke N Bhandari M Johal H Guyatt GH Busse JW

Aims. This 501-patient, multi-centre, randomised controlled trial sought to establish the effect of low-intensity, pulsed, ultrasound (LIPUS) on tibial shaft fractures managed with intramedullary nailing. We conducted an economic evaluation as part of this trial. Patients and Methods. Data for patients’ use of post-operative healthcare resources and time taken to return to work were collected and costed using publicly available sources. Health-related quality of life, assessed using the Health Utilities Index Mark-3 (HUI-3), was used to derive quality-adjusted life years (QALYs). Costs and QALYs were compared between LIPUS and control (a placebo device) from a payer and societal perspective using non-parametric bootstrapping. All costs are reported in 2015 Canadian dollars unless otherwise stated. Results. With a cost per device of $3,995, the mean cost was significantly higher for patients treated with LIPUS versus placebo from a payer (mean increase = $3647, 95% confidence interval (CI) $3244 to $4070; p < 0.001) or a societal perspective (mean increase = $3425, 95% CI $1568 to $5283; p < 0.001). LIPUS did not provide a significant benefit in terms of QALYs gained (mean difference = 0.023 QALYs, 95% CI -0.035 to 0.069; p = 0.474). Incremental cost-effectiveness ratios of LIPUS compared with placebo were $155 433/QALY from a payer perspective and $146 006/QALY from a societal perspective. Conclusion. At the current price, LIPUS is not cost-effective for fresh tibial fractures managed with intramedullary nailing. Cite this article: Bone Joint J 2017;99-B:1526–32


The Journal of Bone & Joint Surgery British Volume
Vol. 63-B, Issue 1 | Pages 92 - 97
1 Feb 1981
Edge A Denham R

An account is given of 38 patients with complicated tibial fractures who were treated by the Portsmouth method of external fixation. Twenty-one patients had multiple injuries and 30 had compound fractures of the tibia. Eighteen fractures wounds were infected, 17 cases required bone grafts and 13 had skin grafts. Thirty-four fractures united in an average time of six months; three patients underwent below-knee amputations; one with neurofibromatosis remains ununited. Those treated primarily by external fixation did better than those in whom external fixation was used after failure of another method. Most fresh fractures united with external callus; and the significance of this in relation to the rigidity of fixation is discussed. The method is easy to use, effective and economical. Improvements to permit adjustment of position and testing for union are suggested. We advise the use of this method of external fixation as the primary treatment for complicated tibial fractures where there is a significant risk of infection or non-union


The Journal of Bone & Joint Surgery British Volume
Vol. 72-B, Issue 1 | Pages 125 - 128
1 Jan 1990
Russell G Henderson R Arnett G

Of 110 consecutive open tibial fractures 90 were reviewed and analysed retrospectively with particular reference to wound closure, method of stabilisation, infection rate and the incidence of non-union. There were 41% Gustilo type I, 39% type II and 20% type III injuries. The incidence of deep infection was 20% after primary wound closure compared with 3% after delayed closure, and eight of the nine non-unions followed primary closure. We conclude that primary wound closure should be avoided in the treatment of open tibial fractures


Orthopaedic Proceedings
Vol. 85-B, Issue SUPP_I | Pages 5 - 5
1 Jan 2003
Joslin C Eastaugh-Waring S Hardy J Cunningham J
Full Access

Tibial fractures represent a heterogeneous group of fractures that are difficult to treat and vary widely in their time to union. Judging when it is safe to remove an external fixator or plaster cast requires clinical and radiological assessments both of which are subjective. Any errors in determining when a fracture has healed can lead to a prolonged treatment time or to refracture. Many methods have been employed to attempt to define clinical union in an objective manner including ultrasound, DEXA scanning, vibration analysis, and fracture stiffness measurements. Stiffness measurements are however time consuming to perform, of debatable clinical significance, and applicable only to fractures treated with external fixators. It has been previously observed. 1,. 2. that weight bearing increases with time post-fracture. It has also been suggested. 3. that the ability of a patient to weight bear on the fractured limb is controlled by a biofeedback mechanism of biological self-control of fracture site strain that will be related to the stiffness of the fracture. We hypothesised that weight-bearing will be closely related to fracture healing and could be used as an alternative measure of healing where other objective measures of healing are not available or are impracticable. A group of ten patients with tibial fractures treated by external fixation were studied. Using a Kistler force plate set into the floor, ground reaction forces for both lower limbs (fractured and non-fractured) were measured during normal walking at three weekly intervals. Concurrent fracture stiffness measurements were made using the Orthofix Orthometer. In 8 patients who made good recoveries, the fixator was removed between 15–20 weeks post injury when the fracture stiffness had reached a minimum of 15 Nm/deg. Weight-bearing through the injured leg was seen to approach 90% of that through the uninjured leg in the 3 weeks prior to fixator removal. Two patients with delayed union achieved weight bearing of less than 40% of normal between 15–20 weeks. They also demonstrated low values of fracture stiffness (< 5 Nm/deg.) and subsequently required operative intervention to achieve union. In this small study of 10 patients, weight bearing appears to correlate well with clinical union. It is quicker and easier to assess than stiffness and potentially has relevance to other fixation methods. We are continuing these measurements on conservatively treated, intra-medullary nailed, and externally fixed tibial fractures


The Journal of Bone & Joint Surgery British Volume
Vol. 82-B, Issue 8 | Pages 1113 - 1116
1 Nov 2000
Keating JF Blachut PA O’Brien PJ Court-Brown CM

Reamed intramedullary nailing was carried out on 57 Gustilo grade-IIIB tibial fractures in 55 patients. After debridement, there was substantial bone loss in 28 fractures (49%). The mean time to union was 43 weeks (14 to 94). When there was no bone loss, the mean time to union was 32 weeks; it was 45 weeks if there was bone loss. Fractures complicated by infection took a mean of 53 weeks to heal. Revision nailing was necessary in 13 fractures (23%) and bone grafting in 15 (26%). In ten fractures (17.5%) infection developed, in four within six weeks of injury and in six more than four months later. Of these, nine were treated successfully, but one patient required an amputation because of osteomyelitis. Our results indicate that reamed intramedullary nailing is a satisfactory treatment for Gustilo grade-III tibial fractures


The Journal of Bone & Joint Surgery British Volume
Vol. 72-B, Issue 5 | Pages 801 - 804
1 Sep 1990
Court-Brown C Wheelwright E Christie J McQueen M

An analysis of 51 type III open tibial fractures treated by external skeletal fixation is presented. The fractures are subdivided according to the classification of Gustilo, Mendoza and Williams (1984) into types IIIa, IIIb and IIIc. The different prognoses of these fracture subtypes is examined. The use of the Hoffmann and Hughes external fixators in the management of type III open tibial fractures is presented and it is suggested that the prognosis is independent of the type of fixator used


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 11 | Pages 1592 - 1595
1 Nov 2010
Ahmed I Robinson CM Patton JT Cook RE

We present two cases of metastatic lung cancer which occurred at the site of a previously united tibial fracture. Both patients were treated with a locked intramedullary nail. The patients presented with metastases at the site of their initial fracture approximately 16 and 13 months after injury respectively. We discuss this unusual presentation and review the relevant literature. We are unaware of any previous reports of a metastatic tumour occurring at the site of an orthopaedic implant used to stabilise a non-pathological fracture. These cases demonstrate the similar clinical presentation of infection and malignancy: a diagnosis which should always be considered in such patients


The Journal of Bone & Joint Surgery British Volume
Vol. 77-B, Issue 3 | Pages 417 - 421
1 May 1995
Court-Brown C McBirnie J

We performed an epidemiological analysis of 523 fractures treated in the Edinburgh Orthopaedic Trauma Unit over a three-year period using modern descriptive criteria. The fractures were defined in terms of their AO morphology and their degree of comminution, location and cause. Closed fractures were classified using the Tscherne grading system and open fractures according to the Gustilo classification. Further analysis of fractures caused by road-traffic accidents and football was carried out. The use of the AO classification allowed the common fracture patterns to be defined. Correlation of the classification systems showed an association between the AO morphological system and the Tscherne and Gustilo classifications. The relative rarity of severe tibial fractures is indicated and it is suggested that in smaller orthopaedic units the infrequency of these fractures has implications for training and the development of treatment protocols


The Journal of Bone & Joint Surgery British Volume
Vol. 76-B, Issue 3 | Pages 389 - 394
1 May 1994
Richardson J Cunningham J Goodship A O'Connor B Kenwright J

We measured fracture stiffness in 212 patients with tibial fractures treated by external fixation. In the first 117 patients (group 1) the decision to remove the fixator and allow independent weight-bearing was made on clinical grounds. In the other 95 patients (group 2) the frames were removed when the fracture stiffness had reached 15 Nm/degree. In group 1 there were eight refractures and in group 2 there was none (p = 0.02, Fisher's exact test). The time to independent weight-bearing was longer in group 1 (median 24 weeks) than in group 2 (21.7 weeks, p = 0.02). The greater precision of our objective measurement was associated with a reduction in refracture rate and in the time taken to achieve independent weight-bearing. We consider that a stiffness of 15 Nm/degree in the sagittal plane provides a useful definition of union of tibial fractures


The Journal of Bone & Joint Surgery British Volume
Vol. 77-B, Issue 3 | Pages 412 - 416
1 May 1995
Richardson J Gardner T Hardy Evans M Kuiper J Kenwright J

We studied the effect of 'dynamisation' on tibial fractures in six patients treated by the Dynamic Axial Fixator. In the early stages, peak cyclic movement at two to four weeks averaged 0.75 mm (0.19 to 1.02) on the medial side of the bone and 0.86 mm (0.21 to 1.25) on the lateral side. The amount of movement correlated with the applied load and the fracture stiffness. After unlocking the fixator column at six weeks, progressive closure of the gap averaged 1.3 mm (0.1 to 3.5). Cyclic movement is produced by early weight-bearing with the fixator column locked. Progressive closure occurs after unlocking the column, and is often associated with a reduction in cyclic movements. The effects of dynamisation on movement at the fracture site should be defined separately, in terms of cyclic movement and of progressive closure


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_8 | Pages 5 - 5
1 May 2018
Calder P Koroma P Wright J Goodier D Taylor S Blunn G Moazen M
Full Access

Aim. To quantify the micro-motion at the fracture gap in a tibial fracture model stabilised with an external fixator. Method. A surrogate model of a tibia and a cadaver leg were fractured and stabilised using a two-ring hexapod external fixator. They were tested initially under static loading and then subjected to vibration. Results. The overall stiffness of the cadaver leg was significantly higher than the surrogate model under static loading. This resulted in a significantly higher facture movement in the surrogate model. In the surrogate model there was no significant difference between the displacement applied via the vibrating platform and the fracture movement at the fracture gap. The fracture movement was however found to be statistically lower during vibration in the cadaver leg. Discussion. The significant difference in stiffness seen between the surrogate and cadaveric model is likely due to multiple factors such as the presence of soft tissues and fibula, including the biomechanical differences between the frame constructs. The fracture movement seen at 200N loading in the cadaveric leg was approximately 1mm which corresponds to partial weight bearing and a displacement shown to promote callus formation. During vibration however, the movements were far less suggesting that micromotion would be insufficient to promote healing. It may be proposed that soft tissues can alter the overall stiffness and fracture movement recorded in biomechanical studies investigating the effect of various devices or therapies


The Bone & Joint Journal
Vol. 95-B, Issue 1 | Pages 111 - 114
1 Jan 2013
Altay MA Ertürk C Altay N Öztürk IA Baykara I Sert C Isikan UE

We compared the intracompartmental pressures (ICPs) of open and closed tibial fractures with the same injury pattern in a rabbit model. In all, 20 six-month-old New Zealand White male rabbits were used. They were randomised into two equal groups of ten rabbits; an open fracture group (group 1) and a closed fracture group (group 2). Each anaesthetised rabbit was subjected to a standardised fracture of the proximal half of the right tibia using a custom-made device. In order to create a grade II open fracture in group 1, a 10 mm segment of fascia and periosteum was excised. The ICP in the anterior compartment was monitored at six-hourly intervals for 48 hours. Although there was a statistically significant difference in ICP values within each group (both p < 0.001), there was no significant difference between the groups for all measurements (all p ≥ 0.089). In addition, in both groups there was a statistically significant increase in ICP within the first 24 hours, whereas there was a statistically significant decrease within the second 24 hours (p < 0.001 for both groups). We conclude that open tibial fractures should be monitored for the development of acute compartment syndrome to the same extent as closed fractures. Cite this paper: Bone Joint J 2013;95-B:111–14


The Journal of Bone & Joint Surgery British Volume
Vol. 73-B, Issue 6 | Pages 959 - 964
1 Nov 1991
Court-Brown C McQueen M Quaba A Christie J

We report the use of Grosse-Kempf reamed intramedullary nailing in the treatment of 41 Gustilo type II and III open tibial fractures. The union times and infection rates were similar to those previously reported for similar fractures treated by external skeletal fixation, but the incidence of malunion was less and fewer required bone grafting. The role of exchange nailing is discussed and a treatment protocol is presented for the management of delayed union and nonunion


The Journal of Bone & Joint Surgery British Volume
Vol. 73-B, Issue 3 | Pages 448 - 451
1 May 1991
Thakur A Patankar J

Seventy-nine open tibial fractures were treated with unilateral uniplanar tubular external fixators. Excellent stability allowed early weight-bearing. All comminuted fractures, with or without bone loss, and some transverse or short oblique fractures with intermediate fragments were treated by early bone grafting through a posterolateral approach. The external fixator was dynamised as soon as periosteal callus was seen on the radiograph. Bone healing times ranged from 11 to 40 weeks (mean 20). Significant ankle stiffness occurred in 10.9% and leg shortening in 2.8%. Pin track infection was seen in 45.2% but was easily controlled with standard management. The external fixation frame allowed excellent functional freedom for Oriental patients to sit cross-legged and squat. Combined with early bone grafting, external fixation is an excellent method for the management of open tibial fractures


Bone & Joint Open
Vol. 5, Issue 1 | Pages 46 - 52
19 Jan 2024
Assink N ten Duis K de Vries JPM Witjes MJH Kraeima J Doornberg JN IJpma FFA

Aims. Proper preoperative planning benefits fracture reduction, fixation, and stability in tibial plateau fracture surgery. We developed and clinically implemented a novel workflow for 3D surgical planning including patient-specific drilling guides in tibial plateau fracture surgery. Methods. A prospective feasibility study was performed in which consecutive tibial plateau fracture patients were treated with 3D surgical planning, including patient-specific drilling guides applied to standard off-the-shelf plates. A postoperative CT scan was obtained to assess whether the screw directions, screw lengths, and plate position were performed according the preoperative planning. Quality of the fracture reduction was assessed by measuring residual intra-articular incongruence (maximum gap and step-off) and compared to a historical matched control group. Results. A total of 15 patients were treated with 3D surgical planning in which 83 screws were placed by using drilling guides. The median deviation of the achieved screw trajectory from the planned trajectory was 3.4° (interquartile range (IQR) 2.5 to 5.4) and the difference in entry points (i.e. plate position) was 3.0 mm (IQR 2.0 to 5.5) compared to the 3D preoperative planning. The length of 72 screws (86.7%) were according to the planning. Compared to the historical cohort, 3D-guided surgery showed an improved surgical reduction in terms of median gap (3.1 vs 4.7 mm; p = 0.126) and step-off (2.9 vs 4.0 mm; p = 0.026). Conclusion. The use of 3D surgical planning including drilling guides was feasible, and facilitated accurate screw directions, screw lengths, and plate positioning. Moreover, the personalized approach improved fracture reduction as compared to a historical cohort. Cite this article: Bone Jt Open 2024;5(1):46–52


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_3 | Pages 37 - 37
23 Feb 2023
van der Gaast N Huitema J Brouwers L Edwards M Hermans E Doornberg J Jaarsma R
Full Access

Classification systems for tibial plateau fractures suffer from poor interobserver agreement, and their value in preoperative assessment to guide surgical fixation strategies is limited. For tibial plateau fractures four major characteristics are identified: lateral split fragment, posteromedial fragment, anterior tubercle fragment, and central zone of comminution. These fracture characteristics support preoperative assessment of fractures and guide surgical decision-making as each specific component requires a respective fixation strategy. We aimed to evaluate the additional value of 3D-printed models for the identification of tibial plateau fracture characteristics in terms of the interobserver agreement on different fracture characteristics. Preoperative images of 40 patients were randomly selected. Nine trauma surgeons, eight senior and eight junior registrars indicated the presence or absence of four fracture characteristics with and without 3D-printed models. The Fleiss kappa was used to determine interobserver agreement for fracture classification and for interpretation, the Landis and Koch criteria were used. 3D-printed models lead to a categorical improvement in interobserver agreement for three of four fracture characteristics: lateral split (Kconv = 0.445 versus K3Dprint = 0.620; P < 0.001), anterior tubercle fragment (Kconv = 0.288 versus K3Dprint = 0.449; P < 0.001) and zone of comminution (Kconv = 0.535 versus K3Dprint = 0.652; P < 0.001). The overall interobserver agreement improved for three of four fracture characteristics after the addition of 3D printed models. For two fracture characteristics, lateral split and zone of comminution, a substantial interobserver agreement was achieved. Fracture characteristics seem to be a more reliable way to assess tibial plateau fractures and one should consider including these in the preoperative assessment of tibial plateau fractures compared to the commonly used classification systems


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_IV | Pages 582 - 582
1 Nov 2011
Bhandari M Dijkman BG Busse JW Walter SD
Full Access

Purpose: Radiographic healing is a common outcome measure in orthopaedic trials and adjudication by outcome assessors is often conducted using only plain radiographs. We explored the effect of adding clinical notes to radiographs in the adjudication process of a pilot trial of tibial shaft fractures. Method: Radiographic and clinical data from a multicenter clinical trial of 51 patients with operatively treated tibial fractures formed the basis of the study data. An independent adjudication committee of three blinded orthopaedic trauma surgeons evaluated radiographs for time to fracture healing. This committee then evaluated clinical notes associated with each radiographic follow up visit and were asked to either revise or maintain their initial impression. We calculated the proportion of time to healing consensus decisions that changed after evaluation of clinical notes. We further examined the contents of the clinical notes and its relative influence on the committee’s decisions. Results: Forty-seven of 51 patients were determined to have radiographic evidence of healing during the trial follow-up period, and consideration of the clinical notes resulted in a change of 40% (19 of 47) of time to healing consensus decisions; however, revised decisions were equally likely to support an earlier or a later time to healing. Conclusion: Addition of clinical notes changed the adjudication committee’s decision of radiographic fracture healing in a substantial number of cases. Our findings suggest that orthopedic trialists should consider the addition of clinical notes to adjudication material in studies of fracture healing


The Journal of Bone & Joint Surgery British Volume
Vol. 73-B, Issue 2 | Pages 316 - 321
1 Mar 1991
Dagher F Roukoz S

We report our experience of the use of the Ilizarov technique to treat nine patients with severe compound tibial fractures. The mean defect in bone was 6.3 cm, and four cases were infected. All nine patients had satisfactory union and function without the use of bone grafts or antibiotics. The Ilizarov technique was very satisfactory; there were no major complications


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVIII | Pages 73 - 73
1 Sep 2012
Busse JW Investigators S Group MUSS Bhandari M
Full Access

Purpose. We explored the role of patients beliefs and attitudes towards their likelihood of recovery from severe physical trauma. Method. We developed and validated an instrument designed to capture the impact of patients beliefs and attitudes towards functional recovery from injury; the Somatic Pre-Occupation and Coping (SPOC) questionnaire. At six weeks post-surgical fixation, we administered the SPOC questionnaire to 359 consecutive patients with operatively managed tibial shaft fractures. We constructed multi-variable regression models to explore the association between SPOC scores and functional outcome at one year, as measured by return to work and Short Form-36 (SF-36) physical component summary (PCS) and mental component summary (MCS) scores. Results. In our adjusted regression models that included pre-injury SF-36 scores, SPOC scores at six weeks post-surgery accounted for 18% of the variation in SF-36 PCS scores and 18% of SF-36 MCS scores at one year. Our adjusted analysis found that for each 14-point increment in SPOC score (14 points being half the standard deviation of the aggregate score) at six weeks the odds of returning to work at 12 months decreased by 40% (odds ratio = 0.60; 95% CI = 0.50 to 0.73). In all models, six week SPOC scores were a far more powerful predictor of functional recovery than age, gender, fracture type, smoking status, or the presence of multi-trauma. Conclusion. The SPOC questionnaire is a valid measurement of illness beliefs and attitudes in tibial fracture patients and is highly predictive of their long-term functional recovery


The Journal of Bone & Joint Surgery British Volume
Vol. 86-B, Issue 6 | Pages 861 - 867
1 Aug 2004
Gopal S Giannoudis PV Murray A Matthews SJ Smith RM

We studied the outcome and functional status of 33 patients with 34 severe open tibial fractures (Gustilo grade IIIb and IIIc). The treatment regime consisted of radical debridement, immediate bony stabilisation and early soft-tissue cover using a muscle flap (free or rotational). The review included standardised assessments of health-related quality of life (SF-36 and Euroqol) and measurement of the following parameters: gait, the use of walking aids, limb-length discrepancy, knee and ankle joint function, muscle wasting and the cosmetic appearance of the limb. Personal comments and overall patient satisfaction were also recorded. The mean follow-up was 46 months (15 to 80). There were 30 Gustilo grade IIIb fractures and and four grade IIIc fractures. Of the 33 patients, 29 had primary internal fixation and four, external fixation; 11 (34%) later required further surgery to achieve union and two needed bone transport procedures to reconstruct large segmental defects. The mean time to union was 41 weeks (12 to 104). Two patients (6.1%) developed deep infection; both resolved with treatment. The mean SF-36 physical and mental scores were 49 and 62 respectively. The mean state of health score for the Euroqol was 68. Patients with isolated tibial fractures had a better outcome than those with other associated injuries on both scoring systems. Knee stiffness was noted in seven patients (21%) and ankle stiffness in 19 (56%); 12 patients (41%) returned to work. Our results compare favourably with previous outcome measurements published for both limb salvage and amputation. All patients were pleased to have retained their limbs


The Journal of Bone & Joint Surgery British Volume
Vol. 81-B, Issue 3 | Pages 481 - 484
1 May 1999
Robinson CM O’Donnell J Will E Keating JF

We made a prospective study of 208 patients with tibial fractures treated by reamed intramedullary nailing. Of these, 11 (5.3%) developed dysfunction of the peroneal nerve with no evidence of a compartment syndrome. The patients with this complication were significantly younger (mean age 25.6 years) and most had closed fractures of the forced-varus type with relatively minor soft-tissue damage. The fibula was intact in three, fractured in the distal or middle third in seven, with only one fracture in the proximal third. Eight of the 11 patients showed a ‘dropped hallux’ syndrome, with weakness of extensor hallucis longus and numbness in the first web space, but no clinical involvement of extensor digitorum longus or tibialis anterior. This was confirmed by nerve-conduction studies in three of the eight patients. There was good recovery of muscle function within three to four months in all cases, but after one year three patients still had some residual tightness of extensor hallucis longus, and two some numbness in the first web space. No patient required further treatment


The Bone & Joint Journal
Vol. 106-B, Issue 9 | Pages 916 - 923
1 Sep 2024
Fricka KB Wilson EJ Strait AV Ho H Hopper, Jr RH Hamilton WG Sershon RA

Aims

The optimal bearing surface design for medial unicompartmental knee arthroplasty (UKA) remains controversial. The aim of this study was to compare outcomes of fixed-bearing (FB) and mobile-bearing (MB) UKAs from a single high-volume institution.

Methods

Prospectively collected data were reviewed for all primary cemented medial UKAs performed by seven surgeons from January 2006 to December 2022. A total of 2,999 UKAs were identified, including 2,315 FB and 684 MB cases. The primary outcome measure was implant survival. Secondary outcomes included 90-day and cumulative complications, reoperations, component revisions, conversion arthroplasties, range of motion, and patient-reported outcome measures. Overall mean age at surgery was 65.7 years (32.9 to 94.3), 53.1% (1,593/2,999) of UKAs were implanted in female patients, and demographics between groups were similar (p > 0.05). The mean follow-up for all UKAs was 3.7 years (0.0 to 15.6).


The Bone & Joint Journal
Vol. 105-B, Issue 7 | Pages 717 - 718
1 Jul 2023
Haddad FS


Orthopaedic Proceedings
Vol. 87-B, Issue SUPP_III | Pages 308 - 308
1 Sep 2005
Harris I Donald G Kadir A
Full Access

Introduction: The role of continuous compartment pressure monitoring to detect compartment syndrome associated with tibia fractures is unclear. Our study aims to assess the impact of continuous compartment pressure monitoring in patients with acute tibial fractures. Method: A randomised controlled trial was performed on 200 consecutive extra-articular tibial shaft fractures presenting to a major metropolitan trauma centre between June 2000 and August 2003. One hundred patients were randomised to continuous compartment pressure monitoring of the anterior compartment for 36 hours. The other group received usual care. The surgical team was alerted if the compartment pressure was within 30mmHg of the diastolic blood pressure. Compartment syndrome was diagnosed on clinical grounds in alert patients. All cases of compartment syndrome were treated with fasciotomy. All patients were followed-up for a minimum of six months. Result: During the study period, three patients presented with acute compartment syndrome and underwent immediate fasciotomy and, consequently, were not entered into the study. In several cases, monitoring revealed pressures within 30 mmHg of diastolic blood pressure, but compartment syndrome was excluded on clinical grounds. The two groups were comparable with regards to age, mechanism of injury and fracture classification. Of the 100 control fractures, there were three cases of compartment syndrome. Each underwent fasciotomy without significant sequelae. Of the 100 monitored fractures, no cases of compartment syndrome were diagnosed. There were no cases of missed compartment syndrome in this study. Continuous compartment pressure monitoring requires regular nurse education and, despite this, in most patients monitoring was not complete. Conclusion: We did not find continuous compartment pressure monitoring useful in diagnosing compartment syndrome in patients with acute tibial fractures or preventing missed compartment syndrome. However, this study is underpowered to detect differences in missed compartment syndrome and it may be subject to trial bias as the level of awareness of compartment syndrome was raised by performing the trial. We no longer perform continuous compartment pressure monitoring at our institution


The Journal of Bone & Joint Surgery British Volume
Vol. 72-B, Issue 3 | Pages 347 - 355
1 May 1990
Sharrard W

A total of 45 tibial shaft fractures, all conservatively treated and with union delayed for more than 16 but less than 32 weeks were entered in a double-blind multi-centre trial. The fractures were selected for their liability to delayed union by the presence of moderate or severe displacement, angulation or comminution or a compound lesion with moderate or severe injury to skin and soft tissues. Treatment was by plaster immobilisation in all, with active electromagnetic stimulation units in 20 patients and dummy control units in 25 patients for 12 weeks. Radiographs were assessed blindly and independently by a radiologist and an orthopaedic surgeon. Statistical analysis showed the treatment groups to be comparable except in their age distribution, but age was not found to affect the outcome and the effect of treatment was consistent for each age group. The radiologist's assessment of the active group showed radiological union in five fractures, progress to union in five but no progress to union in 10. In the control group there was union in one fracture and progress towards union in one but no progress in 23. Using Fisher's exact test, the results were very significantly in favour of the active group (p = 0.002). The orthopaedic surgeon's assessment showed union in nine fractures and absence of union in 11 fractures in the active group. There was union in three fractures and absence of union in 22 fractures in the control group. These results were also significantly in favour of the active group (p = 0.02). It was concluded that pulsed electromagnetic fields significantly influence healing in tibial fractures with delayed union


The Journal of Bone & Joint Surgery British Volume
Vol. 77-B, Issue 6 | Pages 906 - 913
1 Nov 1995
Robinson C McLauchlan G Christie J McQueen M Court-Brown C

We reviewed the results of the treatment of 30 tibial fractures with minor to severe bone loss in 29 patients by early soft-tissue and bony debridement followed by primary locked intramedullary nailing. Subsequent definitive closure was obtained within the first 48 hours usually with a soft-tissue flap, and followed by bone-grafting procedures which were delayed for six to eight weeks after the primary surgery. The time to fracture union and the eventual functional outcome were related to the severity and extent of bone loss. Twenty-nine fractures were soundly united at a mean of 53.4 weeks, with delayed amputation in only one patient. Poor functional outcome and the occurrence of complications were usually due to a departure from the standard protocol for primary management. We conclude that the protocol produces satisfactory results in the management of these difficult fractures, and that intramedullary nailing offers considerable practical advantages over other methods of primary bone stabilisation


Bone & Joint Open
Vol. 2, Issue 4 | Pages 227 - 235
1 Apr 2021
Makaram NS Leow JM Clement ND Oliver WM Ng ZH Simpson C Keating JF

Aims. The primary aim of this study was to identify independent predictors associated with nonunion and delayed union of tibial diaphyseal fractures treated with intramedullary nailing. The secondary aim was to assess the Radiological Union Scale for Tibial fractures (RUST) score as an early predictor of tibial fracture nonunion. Methods. A consecutive series of 647 patients who underwent intramedullary nailing for tibial diaphyseal fractures were identified from a trauma database. Demographic data, comorbidities, smoking status, alcohol consumption, use of non-steroidal anti-inflammatory drugs (NSAIDs), and steroid use were documented. Details regarding mechanism of injury, fracture classification, complications, and further surgery were recorded. Nonunion was defined as the requirement for revision surgery to achieve union. Delayed union was defined as a RUST score < 10 at six months postoperatively. Results. There were 41 nonunions (6.3%), of which 13 were infected (31.7%), and 77 delayed unions (11.9%). There were 127 open fractures (19.6%). Adjusting for confounding variables, NSAID use (odds ratio (OR) 3.50; p = 0.042), superficial infection (OR 3.00; p = 0.026), open fractures (OR 5.44; p < 0.001), and high-energy mechanism (OR 2.51; p = 0.040) were independently associated with nonunion. Smoking (OR 1.76; p = 0.034), open fracture (OR 2.82; p = 0.001), and high-energy mechanism (OR 1.81; p = 0.030) were independent predictors associated with delayed union. The RUST score at six-week follow-up was highly predictive of nonunion (sensitivity and specificity of 75%). Conclusion. NSAID use, high-energy mechanisms, open fractures, and superficial infection were independently associated with nonunion in patients with tibial diaphyseal fractures treated with intramedullary nailing. The six-week RUST score may be useful in identifying patients at risk of nonunion. Cite this article: Bone Jt Open 2021;2(4):227–235


Orthopaedic Proceedings
Vol. 87-B, Issue SUPP_III | Pages 231 - 231
1 Sep 2005
Ali AM Yang L Saleh M
Full Access

Objective: To compare the mechanical stability of fixation of bicondylar tibial plateau fractures using available internal and external fixation techniques. Method: A bicondylar tibial plateau fracture was simulated on a uniform synthetic bone and tested with loading to failure. Following power calculations, seven tibias were used for each fixation method; five types of fixation were tested: 1) Dual plating. 2) Ring Fixator with inter-fragmentary screws. 3) Hybrid fixator (Ring-Bar) with interfragmentary screws. 4) Lateral plate and medial monolateral external fixator. 5) Lateral plate and medial interfragmentary screws. The specimens were tested in compression to failure. The vertical subsidence in either medial or lateral plateau was measured using an electrical transducer. Results: In all cases the mode of failure was consistent with collapse occurring in the medial plateau. There was no significant difference in the ultimate strength between dual plating and the ring fixator [4218N, 4184N respectively; P=0.28, t test]. Failure was seen at lower loads with the other fixation systems (Table). Conclusion: The Ring Fixator and dual plating demonstrated a greater strength and the most stable fixation, choice may depend on tissue viability and surgeon preference. Furthermore mobilisation of the patient may be undertaken earlier with more confidence using these two methods rather than less stable techniques


The Bone & Joint Journal
Vol. 105-B, Issue 7 | Pages 719 - 722
1 Jul 2023
Costa ML Brealey SD Perry DC

Musculoskeletal diseases are having a growing impact worldwide. It is therefore crucial to have an evidence base to most effectively and efficiently implement future health services across different healthcare systems. International trials are an opportunity to address these challenges and have many potential benefits. They are, however, complex to set up and deliver, which may impact on the efficient and timely delivery of a project. There are a number of models of how international trials are currently being delivered across a range of orthopaedic patient populations, which are discussed here. The examples given highlight that the key to overcoming these challenges is the development of trusted and equal partnerships with collaborators in each country. International trials have the potential to address a global burden of disease, and in turn optimize the benefit to patients in the collaborating countries and those with similar health services and care systems.

Cite this article: Bone Joint J 2023;105-B(7):719–722.


The Journal of Bone & Joint Surgery British Volume
Vol. 64-B, Issue 4 | Pages 498 - 499
1 Aug 1982
Shakespeare D Henderson N

The effect of calcaneal traction on the compartmental pressure in the legs of five individuals with tibial fractures was studied. Mean resting pressures without traction were found to be 31.9 mmHg for the deep posterior compartment and 27.0 mmHg for the anterior compartment. For each kilogram weight of traction applied the deep posterior pressure rose by 5.7 per cent of the resting value and the anterior pressure by 1.6 per cent. It is suggested that the weight of traction should be only sufficient to render the patient comfortable and maintain alignment of the limb. Excessive traction is likely to increase the risk of compartmental ischaemia. The application of six kilograms of traction would raise the mean resting pressure by 34 per cent from 31.9 to 42.7 mmHg


The Journal of Bone & Joint Surgery British Volume
Vol. 76-B, Issue 1 | Pages 13 - 19
1 Jan 1994
Tornetta P Bergman M Watnik N Berkowitz G Steuer J

Severe open fractures of the tibia have a high incidence of complications and a poor outcome. The most usual method of stabilisation is by external fixation, but the advent of small diameter locking intramedullary nails has introduced a new option. We report the early results of a randomised, prospective study comparing external fixation with non-reamed locked nails in grade-IIIb open tibial fractures. Of 29 patients, 15 were treated by nails and 14 by external fixation. Both groups had the same initial management, soft-tissue procedures, and early bone grafting. All 29 fractures healed within nine months, but the nailed group had slightly better motion and less final angulation. Complications included one deep infection and two pin-track infections in the external fixator group and one deep infection and one vascular problem in the nailed group. Although the differences in healing and range of motion were not statistically significant, we found that the nailed fractures were consistently easier to manage, especially in terms of soft-tissue procedures and bone grafting. It is the treatment preferred by patients and does not require the same high level of patient compliance as external fixation. The only factors against nailing are the longer operating time and the greater need for fluoroscopy. We consider that locked non-reamed nailing is the treatment of choice for grade-IIIb open tibial fractures


The Journal of Bone & Joint Surgery British Volume
Vol. 72-B, Issue 4 | Pages 615 - 617
1 Jul 1990
Kallio P Michelsson J Lalla M Holm T

Serial serum C-reactive protein (CRP) measurements were made, for three weeks, in 42 consecutive patients with solitary tibial fractures. The CRP response was related to the treatment: lower values were observed in 27 patients treated conservatively than in 15 operated patients. Open reduction and plating resulted in a greater response than closed intramedullary nailing. The timing of the CRP response was related to the timing of the treatment: the highest values were usually recorded two days after admission or operation. The timing of the operation did not affect the degree of CRP response. Neither the site, nor the type of fracture, nor the age of the patient played any role. Awareness of these natural CRP responses after fractures may help in the diagnosis of early post-traumatic and postoperative complications, especially infections


The Journal of Bone & Joint Surgery British Volume
Vol. 75-B, Issue 6 | Pages 914 - 917
1 Nov 1993
Janes G Collopy D Price R Sikorski J

We used dual-energy X-ray absorptiometry (DEXA) to measure the bone mineral content (BMC) of both tibiae in 13 patients who had been treated for a tibial fracture by rigid plate fixation. Within two weeks of plate removal the BMC was significantly greater in the bone that had been under the plate than at the same site in the control tibia. An unplated area of bone near the ankle showed a significant decrease in BMC at the time of plate removal with subsequent return to the level of the control tibia during the ensuing 18 months. We conclude that osteoinductive influences outweigh the potential causes of osteopenia, such as stress shielding and disuse, and that, contrary to expectation, demineralisation is not a factor in the diminished strength of the tibia after plating for fracture


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_IV | Pages 94 - 94
1 Mar 2012
Dahabreh Z Giannoudis P
Full Access

Aim of the study. To estimate and compare the cost implications of the first attempt of treatment of tibial fracture non-unions treated with either autologous bone grafting or BMP-7. Materials and methods. Patients who were successfully treated for fracture non-unions between 2001 and 2005 were included. Exclusion criteria included infected non-union, children, malignancy, or chronic debilitating disease. The decision to use BMP-7 or autogenous bone graft was guided by the defect size and the surgeon's preferred method of treatment. Group 1 (n = 12) received iliac crest bone grafting (ICBG) and group 2 (n=15) received recombinant human Bone Morphogenetic Protein-7 (BMP-7). The total costs incurred during treatment including hospital stay, implants, theatre costs, drains, antibiotics, investigations and outpatient appointments were documented and analysed. Results and costs. (Average £ per patient) Average age was 41.4 and 38.52 years in group 1 and 2 respectively. Total follow up was 2.84 and 2.4 years for group 1 and 2 respectively. Average hospital stay was 10.66 and 8.66 days; time to union was 12.3 and 7.6 months; hospitals costs were £2,133.6 and £1,733.33; theatre costs were £2,413.3 and £906.67; implant costs were £696.4 and £592.3; radiology costs were £570 and £270; outpatient costs were £495.8 and £223.33; BMP7 costs were 3002.2; other costs were £451.6 and £566.27; and the total cost of treatment was £6,830.73 and £7,294.1 in group 1 and 2 respectively. Conclusion. In this study, the average cost of treatment of a tibial fracture non-union with autologous bone grafting was 6.7 % higher than the cost incurred with BMP7. Most of the costs incurred (41.1 %) in the BMP7 group were related to the actual price of BMP7. The cost difference between the two groups of patients wasn't statistically significantly higher


The Journal of Bone & Joint Surgery British Volume
Vol. 75-B, Issue 4 | Pages 645 - 649
1 Jul 1993
Hardy Conlan D Hay S Gregg P

The changes in serum adjusted ionised calcium and parathyroid hormone (PTH) were prospectively studied in 32 patients with isolated tibial fractures, treated conservatively. We measured serum albumin, adjusted total calcium, phosphate, pH, adjusted ionised calcium and PTH at intervals until the fractures had healed. The mean ionised calcium adjusted for pH fell within 24 hours of injury, and then rose to a peak at between four and six weeks. These changes cannot be explained by changes in serum pH or PTH. The restoration of normal ionised calcium levels after fracture coincided with the period when the callus was being calcified. Analysis of the changes in ionised calcium, phosphate and PTH suggests that PTH levels alter in response to changes in ionised calcium levels. PTH is highest immediately after fracture and lowest, often not recordable, at six weeks. The cause of the changes in the ionised calcium level has yet to be elucidated


The Journal of Bone & Joint Surgery British Volume
Vol. 58-B, Issue 4 | Pages 471 - 473
1 Nov 1976
Acland R Smith P

A case is described in which a large area of unstable skin overlying a tibial fracture was replaced by a single stage skin flap transfer, using microvascular surgical techniques. The shortening of treatment time and the improvement in the local blood supply compared to that provided by orthodox skin flaps are noted. The improved blood supply at the fracture site may have encouraged bony union


The Journal of Bone & Joint Surgery British Volume
Vol. 84-B, Issue 1 | Pages 15 - 18
1 Jan 2002
Whelan DB Bhandari M McKee MD Guyatt GH Kreder HJ Stephen D Schemitsch EH

The reliability of the radiological assessment of the healing of tibial fractures remains undetermined. We examined the inter- and intraobserver agreement of the healing of such fractures among four orthopaedic trauma surgeons who, on two separate occasions eight weeks apart, independently assessed the radiographs of 30 patients with fractures of the tibial shaft which had been treated by intramedullary fixation. The radiographs were selected from a database to represent fractures at various stages of healing. For each radiograph, the surgeon scored the degree of union, quantified the number of cortices bridged by callus or with a visible fracture line, described the extent and quality of the callus, and provided an overall rating of healing. The interobserver chance-corrected agreement using a quadratically weighted kappa (κ) statistic in which values of 0.61 to 0.80 represented substantial agreement were as follows: radiological union scale (κ = 0.60); number of cortices bridged by callus (κ = 0.75); number of cortices with a visible fracture line (κ = 0.70); the extent of the callus (κ = 0.57); and general impression of fracture healing (κ = 0.67). The intraobserver agreement of the overall impression of healing (κ = 0.89) and the number of cortices bridged by callus (κ = 0.82) or with a visible fracture line (κ = 0.83) was almost perfect. There are no validated scales which allow surgeons to grade fracture healing radiologically. Among those examined, the number of cortices bridged by bone appears to be a reliable, and easily measured radiological variable to assess the healing of fractures after intramedullary fixation


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_II | Pages 350 - 350
1 May 2010
Dahabreh Z Kanakaris N Giannoudis P
Full Access

Purpose: To estimate and compare the direct medical cost implications of the first attempt of treatment of tibial fracture non-unions treated with either autologous bone grafting or BMP-7. Methods: Patients who were successfully treated for fracture non-unions between 2001 and 2005 were enrolled. Exclusion criteria included a diagnosis of an infected nonunion, children, malignancy, or chronic debilitating disease. The decision to use BMP-7 or autogenous bone graft was guided by the defect size as well as the treating surgeon’s preferred method of treatment. Group 1 received iliac crest bone grafting (ICBG) and Group 2 received recombinant human Bone Morphogenetic Protein-7 (BMP–7) as the first line of treatment. The direct medical costs of treatment – including hospital stay, implants, theatre costs, drains, antibiotics, investigations and outpatient appointments were documented and analysed. Results: The study sample consisted of 27 patients (14 females). Group 1 and Group 2 included 12 patients (4 females) and 15 patients (5 females) respectively. The mean age was 41.4 and 38.5 years respectively. The average hospital stay was 7.66 for the ICBG and 5,66 for the BMP7 patients (p=0.051). The follow-up period for Group 1 was 2.84 and 2.4 years for Group 2. The average time to union was 15.3 and 10.6 weeks respectively and this was statistically significant (p< 0.05). The overall direct medical costs on average reached the sum of £6,830.73 and £7,294.1 respectively. The hospital’s, operating theatre’s and outpatient’s direct medical costs were statistically significant (p< 0.05) more for the ICBG group. The implants costs did not significantly differ between the 2 groups and the second group’s costs were mostly raised due to the actual cost of the BMP7 (£3,002.2). Conclusion and Significance: In this study, the average cost of treatment of a tibial fracture non-union with BMP7 was 6.7% higher than the cost incurred with autologous bone grafting. Most of the costs incurred (41.1%) in the BMP7 group were related to the actual price of BMP7. The direct medical cost difference between the two groups of patients wasn’t statistically significantly higher


Bone & Joint Open
Vol. 1, Issue 8 | Pages 481 - 487
11 Aug 2020
Garner MR Warner SJ Heiner JA Kim YT Agel J

Aims. To compare results of institutional preferences with regard to treatment of soft tissues in the setting of open tibial shaft fractures. Methods. We present a retrospective review of open tibial shaft fractures at two high-volume level 1 trauma centres with differing practices with regard to the acute management of soft tissues. Site 1 attempts acute primary closure, while site 2 prefers delayed closure/coverage. Comparisons include percentage of primary closure, number of surgical procedures until definitive closure, percentage requiring soft tissue coverage, and percentage of 90-day wound complication. Results. Overall, there were 219 patients at site 1 and 282 patients at site 2. Differences in rates of acute wound closure were seen (168 (78%) at site 1 vs 101 (36%) at site 2). A mean of 1.5 procedures for definitive closure was seen at site 1 compared to 3.4 at site 2. No differences were seen in complication, nonunion, or amputation rates. Similar results were seen in a sub-analysis of type III injuries. Conclusion. Comparing outcomes of open tibial shaft fractures at two institutions with different rates initial wound management, no differences were seen in 90-day wound complications, nonunion rates, or need for amputation. Attempted acute closure resulted in a lower number of planned secondary procedures when compared with planned delayed closure. Providers should consider either acute closure or delayed coverage based on the injury characteristics, surgeon preference and institutional resources without concern that the decision at the time of index surgery will lead to an increased risk of complication. Cite this article: Bone Joint Open 2020;1-8:481–487


Bone & Joint Open
Vol. 2, Issue 10 | Pages 796 - 805
1 Oct 2021
Plumarom Y Wilkinson BG Willey MC An Q Marsh L Karam MD

Aims

The modified Radiological Union Scale for Tibia (mRUST) fractures score was developed in order to assess progress to union and define a numerical assessment of fracture healing of metadiaphyseal fractures. This score has been shown to be valuable in predicting radiological union; however, there is no information on the sensitivity, specificity, and accuracy of this index for various cut-off scores. The aim of this study is to evaluate sensitivity, specificity, accuracy, and cut-off points of the mRUST score for the diagnosis of metadiaphyseal fractures healing.

Methods

A cohort of 146 distal femur fractures were retrospectively identified at our institution. After excluding AO/OTA type B fractures, nonunions, follow-up less than 12 weeks, and patients aged less than 16 years, 104 sets of radiographs were included for analysis. Anteroposterior and lateral femur radiographs at six weeks, 12 weeks, 24 weeks, and final follow-up were separately scored by three surgeons using the mRUST score. The sensitivity and specificity of mean mRUST score were calculated using clinical and further radiological findings as a gold standard for ultimate fracture healing. A receiver operating characteristic curve was also performed to determine the cut-off points at each time point.


The Bone & Joint Journal
Vol. 97-B, Issue 8 | Pages 1118 - 1125
1 Aug 2015
Kwasnicki RM Hettiaratchy S Okogbaa J Lo B Yang G Darzi A

In this study we quantified and characterised the return of functional mobility following open tibial fracture using the Hamlyn Mobility Score. A total of 20 patients who had undergone reconstruction following this fracture were reviewed at three-month intervals for one year. An ear-worn movement sensor was used to assess their mobility and gait. The Hamlyn Mobility Score and its constituent kinematic features were calculated longitudinally, allowing analysis of mobility during recovery and between patients with varying grades of fracture. The mean score improved throughout the study period. Patients with more severe fractures recovered at a slower rate; those with a grade I Gustilo-Anderson fracture completing most of their recovery within three months, those with a grade II fracture within six months and those with a grade III fracture within nine months.

Analysis of gait showed that the quality of walking continued to improve up to 12 months post-operatively, whereas the capacity to walk, as measured by the six-minute walking test, plateaued after six months.

Late complications occurred in two patients, in whom the trajectory of recovery deviated by > 0.5 standard deviations below that of the remaining patients. This is the first objective, longitudinal assessment of functional recovery in patients with an open tibial fracture, providing some clarification of the differences in prognosis and recovery associated with different grades of fracture.

Cite this article: Bone Joint J 2015; 97-B:1118–25.


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_5 | Pages 4 - 4
1 Mar 2021
Rosell CC Goma-Camps MV Mateu CA Calderer LC Pérez-Cardona PC
Full Access

Aim

The reconstruction of bone critical size defects of the tibia is one of the most complex therapeutic challenges in the orthopedic field. This study aims to describe and evaluate our three-staged surgical protocol of reconstruction of infected defects of the tibia emphasizing in limb salvage rate, resolution of infection, functional outcome and patient satisfaction.

Method

A retrospective review was performed in all cases of complex infected tibia fracture with combined soft and bone tissue loss treated in a specialized limb reconstruction center between 2010 and 2018. In all cases, a three-stage protocol was performed: 1) Infected-limb damage control with radical debridement, 2) Soft tissue coverage with vascularized or local flap 3) Bone reconstruction procedure. The minimum follow-up required was 12 months after external fixator removal.


The Journal of Bone & Joint Surgery British Volume
Vol. 81-B, Issue 6 | Pages 963 - 968
1 Nov 1999
Krettek C Stephan C Schandelmaier P Richter M Pape HC Miclau T

Intramedullary nailing of metaphyseal fractures may be associated with deformity as a result of instability after fixation. Our aim was to evaluate the clinical use of Poller screws (blocking screws) as a supplement to stability after fixation with statically locked intramedullary nails of small diameter. We studied, prospectively, 21 tibial fractures, 10 in the proximal third and 11 in the distal third in 20 patients after the insertion of Poller screws over a mean period of 18.5 months (12 to 29). All fractures had united. Healing was evident radiologically at a mean of 5.4 ± 2.1 months (3 to 12) with a mean varus-valgus alignment of −1.0° (−5 to 3) and mean antecurvatum-recurvatum alignment of 1.6° (−6 to 11). The mean loss of reduction between placement of the initial Poller screw and follow-up was 0.5° in the frontal plane and 0.4° in the sagittal plane. There were no complications related to the Poller screw. The clinical outcome, according to the Karström-Olerud score, was not influenced by previous or concomitant injuries in 18 patients and was judged as excellent in three (17%), good in seven (39%), satisfactory in six (33%), fair in one (6%), and poor in one (6%)


The Journal of Bone & Joint Surgery British Volume
Vol. 67-B, Issue 4 | Pages 650 - 655
1 Aug 1985
Goodship A Kenwright J

Although it has been well established that fracture healing is influenced by the mechanical environment, the optimal parameters have not yet been established. In two groups of sheep an experimental tibial diaphysial fracture was created, and stabilised using external skeletal fixation. In one group rigid fixation was maintained throughout fracture healing; in the other group controlled axial micromovement, with a loading regime known to be osteogenic in intact bones, was applied for a short period daily. A significant improvement in healing was associated with the application of controlled micromovement. Data from these experiments provide the basis for improving the conditions for fracture healing and may assist in the prevention of delayed union


Bone & Joint Open
Vol. 4, Issue 4 | Pages 273 - 282
20 Apr 2023
Gupta S Yapp LZ Sadczuk D MacDonald DJ Clement ND White TO Keating JF Scott CEH

Aims. To investigate health-related quality of life (HRQoL) of older adults (aged ≥ 60 years) after tibial plateau fracture (TPF) compared to preinjury and population matched values, and what aspects of treatment were most important to patients. Methods. We undertook a retrospective, case-control study of 67 patients at mean 3.5 years (SD 1.3; 1.3 to 6.1) after TPF (47 patients underwent fixation, and 20 nonoperative management). Patients completed EuroQol five-dimension three-level (EQ-5D-3L) questionnaire, Lower Limb Function Scale (LEFS), and Oxford Knee Scores (OKS) for current and recalled prefracture status. Propensity score matching for age, sex, and deprivation in a 1:5 ratio was performed using patient level data from the Health Survey for England to obtain a control group for HRQoL comparison. The primary outcome was the difference in actual (TPF cohort) and expected (matched control) EQ-5D-3L score after TPF. Results. TPF patients had a significantly worse EQ-5D-3L utility (mean difference (MD) 0.09, 95% confidence interval (CI) 0.00 to 0.16; p < 0.001) following their injury compared to matched controls, and had a significant deterioration (MD 0.140, 95% CI 0 to 0.309; p < 0.001) relative to their preoperative status. TPF patients had significantly greater pre-fracture EQ-5D-3L scores compared to controls (p = 0.003), specifically in mobility and pain/discomfort domains. A decline in EQ-5D-3L greater than the minimal important change of 0.105 was present in 36/67 TPF patients (53.7%). Following TPF, OKS (MD -7; interquartile range (IQR) -1 to -15) and LEFS (MD -10; IQR -2 to -26) declined significantly (p < 0.001) from pre-fracture levels. Of the 12 elements of fracture care assessed, the most important to patients were getting back to their own home, having a stable knee, and returning to normal function. Conclusion. TPFs in older adults were associated with a clinically significant deterioration in HRQoL compared to preinjury level and age, sex, and deprivation matched controls for both undisplaced fractures managed nonoperatively and displaced or unstable fractures managed with internal fixation. Cite this article: Bone Jt Open 2023;4(4):273–282


Aims. Our objective was to conduct a systematic review and meta-analysis, to establish whether differences arise in clinical outcomes between autologous and synthetic bone grafts in the operative management of tibial plateau fractures. Methods. A structured search of MEDLINE, EMBASE, the online archives of Bone & Joint Publishing, and CENTRAL databases from inception until 28 July 2021 was performed. Randomized, controlled, clinical trials that compared autologous and synthetic bone grafts in tibial plateau fractures were included. Preclinical studies, clinical studies in paediatric patients, pathological fractures, fracture nonunion, or chondral defects were excluded. Outcome data were assessed using the Risk of Bias 2 (ROB2) framework and synthesized in random-effect meta-analysis. The Preferred Reported Items for Systematic Review and Meta-Analyses guidance was followed throughout. Results. Six studies involving 353 fractures were identified from 3,078 records. Following ROB2 assessment, five studies (representing 338 fractures) were appropriate for meta-analysis. Primary outcomes showed non-significant reductions in articular depression at immediate postoperative (mean difference -0.45 mm, p = 0.25, 95%confidence interval (CI) -1.21 to 0.31, I. 2. = 0%) and long-term (> six months, standard mean difference -0.56, p = 0.09, 95% CI -1.20 to 0.08, I. 2. = 73%) follow-up in synthetic bone grafts. Secondary outcomes included mechanical alignment, limb functionality, and defect site pain at long-term follow-up, perioperative blood loss, duration of surgery, occurrence of surgical site infections, and secondary surgery. Mean blood loss was lower (90.08 ml, p < 0.001, 95% CI 41.49 to 138.67) and surgery was shorter (16.17 minutes, p = 0.04, 95% CI 0.39 to 31.94) in synthetic treatment groups. All other secondary measures were statistically comparable. Conclusion. All studies reported similar methodologies and patient populations; however, imprecision may have arisen through performance variation. These findings supersede previous literature and indicate that, despite perceived biological advantages, autologous bone grafting does not demonstrate superiority to synthetic grafts. When selecting a void filler, surgeons should consider patient comorbidity, environmental and societal factors in provision, and perioperative and postoperative care provision. Cite this article: Bone Jt Open 2022;3(3):218–228


The Bone & Joint Journal
Vol. 102-B, Issue 5 | Pages 632 - 637
1 May 2020
Gonzalez LJ Hildebrandt K Carlock K Konda SR Egol KA

Aims. Tibial plateau fractures are serious injuries about the knee that have the potential to affect patients’ long-term function. To our knowledge, this is the first study to use patient-reported outcomes (PROs) with a musculoskeletal focus to assess the long-term outcome, as compared to a short-term outcome baseline, of tibial plateau fractures treated using modern techniques. Methods. In total, 102 patients who sustained a displaced tibial plateau fracture and underwent operative repair by one of three orthopaedic traumatologists at a large, academic medical centre and had a minimum of five-year follow-up were identified. Breakdown of patients by Schatzker classification is as follows: two (1.9%) Schatzker I, 54 (50.9%) Schatzker II, two (1.9%) Schatzker III, 13 (12.3%) Schatzker IV, nine (8.5%) Schatzker V, and 26 (24.5%) Schatzker VI. Follow-up data obtained included: Visual Analogue Scale (VAS) or Numeric Rating Scale (NRS) pain scores, Short Musculoskeletal Functional Assessment (SMFA), and knee range of movement (ROM). Data at latest follow-up were then compared to 12-month data using a paired t-test. Results. Patient-reported functional outcomes as assessed by overall SMFA were statistically significantly improved at five years (p < 0.001) compared with one-year data from the same patients. Patients additionally reported an improvement in the Standardized Mobility Index (p < 0.001), Standardized Emotional Index (p < 0.001), as well as improvement in Standardized Bothersome Index (p = 0.003) between the first year and latest follow-up. Patient-reported pain and knee ROM were similar at five years to their one-year follow-up. In total, 15 of the patients had undergone subsequent orthopaedic surgery for their knees at the time of most recent follow-up. Of note, only one patient had undergone knee arthroplasty following plateau fixation related to post-traumatic osteoarthritis (OA). Conclusion. Knee pain following tibial plateau fracture stabilizes at one year. However, PROs continue to improve beyond one year following tibial plateau fracture, at least in a statistical sense, if not also clinically. Patients displayed statistical improvement across nearly all SMFA index scores at their minimum five-year follow-up compared with their one-year follow-up. Cite this article: Bone Joint J 2020;102-B(5):632–637


The Bone & Joint Journal
Vol. 101-B, Issue 8 | Pages 1009 - 1014
1 Aug 2019
Ramoutar DN Lefaivre K Broekhuyse H Guy P O’Brien P

Aims. The aim of this study was to determine the trajectory of recovery following fixation of tibial plateau fractures up to five-year follow-up, including simple (Schatzker I-IV) versus complex (Schatzker V-VI) fractures. Patients and Methods. Patients undergoing open reduction and internal fixation (ORIF) for tibial plateau fractures were enrolled into a prospective database. Functional outcome, using the 36-Item Short Form Health Survey Physical Component Summary (SF-36 PCS), was collected at baseline, six months, one year, and five years. The trajectory of recovery for complex fractures (Schatzker V and VI) was compared with simple fractures (Schatzker I to IV). Minimal clinically important difference (MCID) was calculated between timepoints. In all, 182 patients were enrolled: 136 (74.7%) in simple and 46 (25.3%) in complex. There were 103 female patients and 79 male patients with a mean age of 45.8 years (15 to 86). Results. Mean SF-36 PCS improved significantly in both groups from six to 12 months (p < 0.001) and one to five years (simple, p = 0.008; complex, p = 0.007). In both groups, the baseline scores were not reached at five years. The SF-36 PCS was significantly higher in the simple group compared with the complex group at both six months (p = 0.007) and 12 months (p = 0.01), but not at five years (p = 0.17). Between each timepoint, approximately 50% or more of the patients in each group achieved an MCID in their score change, indicating a significant clinical change in condition. The complex group had a much larger drop off in the first six months, with comparable proportions achieving MCID at the subsequent time intervals. Conclusion. Tibial plateau fracture recovery was characterized overall by an initial decline in functional outcome from baseline, followed by a steep improvement from six to 12 months, and ongoing recovery up to five years. In simple patterns, patients tended to achieve a higher functional score by six months compared with the complex patterns. However, comparable functional scores between the groups achieved only at the five-year point suggest later recovery in the complex group. Function does not improve to baseline by five years in either group. This information is useful in counselling patients about the course of prospective recovery. Cite this article: Bone Joint J 2019;101-B:1009–1014


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 4 | Pages 544 - 548
1 Apr 2012
Macri F Marques LF Backer RC Santos MJ Belangero WD

There is no absolute method of evaluating healing of a fracture of the tibial shaft. In this study we sought to validate a new clinical method based on the systematic observation of gait, first by assessing the degree of agreement between three independent observers regarding the gait score for a given patient, and secondly by determining how such a score might predict healing of a fracture.

We used a method of evaluating gait to assess 33 patients (29 men and four women, with a mean age of 29 years (15 to 62)) who had sustained an isolated fracture of the tibial shaft and had been treated with a locked intramedullary nail. There were 15 closed and 18 open fractures (three Gustilo and Anderson grade I, seven grade II, seven grade IIIA and one grade IIIB). Assessment was carried out three and six months post-operatively using videos taken with a digital camera. Gait was graded on a scale ranging from 1 (extreme difficulty) to 4 (normal gait). Bivariate analysis included analysis of variance to determine whether the gait score statistically correlated with previously validated and standardised scores of clinical status and radiological evidence of union.

An association was found between the pattern of gait and all the other variables. Improvement in gait was associated with the absence of pain on weight-bearing, reduced tenderness over the fracture, a higher Radiographic Union Scale in Tibial Fractures score, and improved functional status, measured using the Brazilian version of the Short Musculoskeletal Function Assessment questionnaire (all p < 0.001). Although further study is needed, the analysis of gait in this way may prove to be a useful clinical tool.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_1 | Pages 156 - 156
1 Jan 2013
Briant-Evans T Hobby J Stranks G Rossiter N
Full Access

The Fixion expandable nailing system provides an intramedullary fracture fixation solution without the need for locking screws. Proponents of this system have demonstrated shorter surgery times with rapid fracture healing, but several centres have reported suboptimal results with loss of fixation. This is the largest comparative series to be reported to date. We compared outcomes between 50 consecutive diaphyseal tibial fractures treated with a Fixion device at our institution to an age, sex and fracture configuration matched series of 57 fractures at a neighbouring hospital treated with a conventional interlocked intramedullary nail. Minimum follow up time was 2 years. Operating time was significantly reduced in the Fixion group (mean 61 minutes, range 20–99) compared to the interlocked group (88 minutes, 52–93), p< 0.00001. The union rate was no different between the Fixion group (93.9%) and the interlocked group (96.5%), p=0.527. Time to clinical and radiological union was significantly faster in the Fixion group (median 85 days, range 42–243) compared to the interlocked group (119, 70–362), p< 0.0001. The overall reoperation rate was lower in the Fixion series (24.5% vs 38.6%, p=0.121), although the majority of reoperations in the interlocked group were more minor, for screw removal. 3 Fixion nails were revised for fixation failure and 2 manipulations were required for rotational deformities after falls; all of these patients were non-compliant with post-operative instructions. There were no fixation failures in the interlocked group. 3 fractures were noted to propagate during inflation of Fixion nails. The Fixion nail is faster to implant and allows more physiological loading of the fracture, with a faster union time. However, these advantages are offset by a reduction in construct stability. Our results have demonstrated a learning curve with a reduction in complications as our indications were narrowed, avoiding osteoporotic, multifragmentary, unstable fractures and non-compliant patients


Bone & Joint Research
Vol. 9, Issue 6 | Pages 258 - 267
1 Jun 2020
Yao X Zhou K Lv B Wang L Xie J Fu X Yuan J Zhang Y

Aims. Tibial plateau fractures (TPFs) are complex injuries around the knee caused by high- or low-energy trauma. In the present study, we aimed to define the distribution and frequency of TPF lines using a 3D mapping technique and analyze the rationalization of divisions employed by frequently used classifications. Methods. In total, 759 adult patients with 766 affected knees were retrospectively reviewed. The TPF fragments on CT were multiplanar reconstructed, and virtually reduced to match a 3D model of the proximal tibia. 3D heat mapping was subsequently created by graphically superimposing all fracture lines onto a tibia template. Results. The cohort included 405 (53.4%) cases with left knee injuries, 347 (45.7%) cases with right knee injuries, and seven (0.9%) cases with bilateral injuries. On mapping, the hot zones of the fracture lines were mainly concentrated around the anterior cruciate ligament insertion, posterior cruciate ligament insertion, and the inner part of the lateral condyle that extended to the junctional zone between Gerdy’s tubercle and the tibial tubercle. Moreover, the cold zones were scattered in the posteromedial fragment, superior tibiofibular syndesmosis, Gerdy’s tubercle, and tibial tubercle. TPFs with different Orthopaedic Trauma Association/AO Foundation (OTA/AO) subtypes showed peculiar characteristics. Conclusion. TPFs occurred more frequently in the lateral and intermedial column than in the medial column. Fracture lines of tibial plateau occur frequently in the transition zone with marked changes in cortical thickness. According to 3D mapping, the four-column and nine-segment classification had a high degree of matching as compared to the frequently used classifications. Cite this article: Bone Joint Res 2020;9(6):258–267


The Bone & Joint Journal
Vol. 102-B, Issue 7 | Pages 861 - 867
1 Jul 2020
Hiranaka T Yoshikawa R Yoshida K Michishita K Nishimura T Nitta S Takashiba K Murray D

Aims. Cementless unicompartmental knee arthroplasty (UKA) has advantages over cemented UKA, including improved fixation, but has a higher risk of tibial plateau fracture, particularly in Japanese patients. The aim of this multicentre study was to determine when cementless tibial components could safely be used in Japanese patients based on the size and shape of the tibia. Methods. The study involved 212 cementless Oxford UKAs which were undertaken in 174 patients in six hospitals. The medial eminence line (MEL), which is a line parallel to the tibial axis passing through the tip of medial intercondylar eminence, was drawn on preoperative radiographs. Knees were classified as having a very overhanging medial tibial condyle if this line passed medial to the medial tibial cortex. They were also classified as very small if a size A/AA tibial component was used. Results. The overall rate of fracture was 8% (17 out of 212 knees). The rate was higher in knees with very overhanging condyles (Odds ratio (OR) 13; p < 0.001) and with very small components (OR 7; p < 0.001). The OR was 21 (p < 0.001) in those with both very overhanging condyles and very small components. In all, 69% of knees (147) had neither very overhanging nor very small components, and the fracture rate in these patients was 1.4% (2 out of 147 knees). Males had a significantly reduced risk of fracture (OR 0.13; p = 0.002), probably because no males required very small components and females were more likely to have very overhanging condyles (OR 3; p = 0.013). 31% of knees (66) were in males and in these the rate of fracture was 1.5% (1 out of 66 knees). Conclusion. The rate of tibial plateau fracture in Japanese patients undergoing cementless UKA is high. We recommend that cemented tibial fixation should be used in Japanese patients who require very small components or have very overhanging condyles, as identified from preoperative radiographs. In the remaining 69% of knees cementless fixation can be used. This approach should result in a low rate of fracture. Cite this article: Bone Joint J 2020;102-B(7):861–867


The Journal of Bone & Joint Surgery British Volume
Vol. 75-B, Issue 3 | Pages 450 - 452
1 May 1993
Sarangi P Ward A Smith E Staddon G Atkins R

We made a prospective study of the incidence and natural history of algodystrophy and associated changes in bone mineral density in the ankles and feet of 60 consecutive patients who had suffered unilateral fractures of the tibial shaft. At bone union, 18 patients showed signs of algodystrophy. Its development was independent of the type of fracture management and of the severity of injury. Patients with algodystrophy lost significantly more bone mineral than did those without but the degree of this loss was independent of the type of treatment and of the time to fracture union. In most cases the symptoms resolved within six months of fracture union but in four patients they were still present at one year and two of these had not returned to work.


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 10 | Pages 1424 - 1426
1 Oct 2011
Delaney RA Burns A Emans JB

Arteriovenous fistula formation after a closed extremity fracture is rare. We present the case of an 11-year-old boy who developed an arteriovenous fistula between the anterior tibial artery and popliteal vein after closed fractures of the proximal tibia and fibula. The fractures were treated by closed reduction and casting. A fistula was diagnosed 12 weeks after the injury. It was treated by embolisation with coils. Subsequent angiography and ultrasonography confirmed patency of the popliteal vein and anterior and posterior tibial and peroneal arteries, with no residual shunting through the fistula. The fractures healed uneventfully and he returned to full unrestricted activities 21 weeks after his injury.


Bone & Joint Research
Vol. 8, Issue 8 | Pages 357 - 366
1 Aug 2019
Zhang B Sun H Zhan Y He Q Zhu Y Wang Y Luo C

Objectives. CT-based three-column classification (TCC) has been widely used in the treatment of tibial plateau fractures (TPFs). In its updated version (updated three-column concept, uTCC), a fracture morphology-based injury mechanism was proposed for effective treatment guidance. In this study, the injury mechanism of TPFs is further explained, and its inter- and intraobserver reliability is evaluated to perfect the uTCC. Methods. The radiological images of 90 consecutive TPF patients were collected. A total of 47 men (52.2%) and 43 women (47.8%) with a mean age of 49.8 years (. sd. 12.4; 17 to 77) were enrolled in our study. Among them, 57 fractures were on the left side (63.3%) and 33 were on the right side (36.7%); no bilateral fracture existed. Four observers were chosen to classify or estimate independently these randomized cases according to the Schatzker classification, TCC, and injury mechanism. With two rounds of evaluation, the kappa values were calculated to estimate the inter- and intrareliability. Results. The overall inter- and intraobserver agreements of the injury mechanism were substantial (κ. inter. = 0.699, κ. intra. = 0.749, respectively). The initial position and the force direction, which are two components of the injury mechanism, had substantial agreement for both inter-reliability or intrareliability. The inter- and intraobserver agreements were lower in high-energy fractures (Schatzker types IV to VI; κ. inter. = 0.605, κ. intra. = 0.721) compared with low-energy fractures (Schatzker types I to III; κ. inter. = 0.81, κ. intra. = 0.832). The inter- and intraobserver agreements were relatively higher in one-column fractures (κ. inter. = 0.759, κ. intra. = 0.801) compared with two-column and three-column fractures. Conclusion. The complete theory of injury mechanism of TPFs was first put forward to make the TCC consummate. It demonstrates substantial inter- and intraobserver agreement generally. Furthermore, the injury mechanism can be promoted clinically. Cite this article: B-B. Zhang, H. Sun, Y. Zhan, Q-F. He, Y. Zhu, Y-K. Wang, C-F. Luo. Reliability and repeatability of tibial plateau fracture assessment with an injury mechanism-based concept. Bone Joint Res 2019;8:357–366. DOI: 10.1302/2046-3758.88.BJR-2018-0331.R1


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_7 | Pages 13 - 13
1 May 2021
Davies-Branch NR Oliver WM Davidson EK Duckworth AD Keating JF White TO
Full Access

The aim was to report operative complications, radiographic and patient-reported outcomes following lateral tibial plateau fracture fixation augmented with calcium phosphate cement (CPC). From 2007–2018, 187 patients (median age 57yrs [range 22–88], 63% female [n=118/187]) with a Schatzker II/III fracture were retrospectively identified. There were 103 (55%) ORIF and 84 (45%) percutaneous fixation procedures. Complications and radiographic outcomes were determined from outpatient records and radiographs. Long-term follow-up was via telephone interview. At a median of 6 months (range 0.1–138) postoperatively, complications included superficial peroneal nerve injury (0.5%, n=1/187), infection (6.4%, n=12/187), prominent metalwork (10.2%, n=19/187) and post-traumatic osteoarthritis (PTOA; 5.3%, n=10/187). The median postoperative medial proximal tibial angle was 89o (range 82–107) and posterior proximal tibial angle 82o (range 45–95). Three patients (1.6%) underwent debridement for infection and 27 (14.4%) required metalwork removal. Seven patients (4.2%) underwent total knee replacement for PTOA. Sixty percent of available patients (n=97/163) completed telephone follow-up at a median of 6yrs (range 1–13). The median Oxford Knee Score was 42 (range 3–48), Knee injury and Osteoarthritis Outcome Score 88 (range 10–100), EuroQol 5-Dimension score 0.812 (range −0.349–1.000) and Visual Analogue Scale 75 (range 10–100). There were no significant differences between ORIF and percutaneous fixation in patient-reported outcome (all p>0.05). Fixation augmented with CPC is safe and effective for lateral tibial plateau fractures, with a low complication rate and good long-term knee function and health-related quality of life. Percutaneous fixation offers a viable alternative to ORIF with no detriment to patient-reported outcome


The Bone & Joint Journal
Vol. 106-B, Issue 1 | Pages 28 - 37
1 Jan 2024
Gupta S Sadczuk D Riddoch FI Oliver WM Davidson E White TO Keating JF Scott CEH

Aims. This study aims to determine the rate of and risk factors for total knee arthroplasty (TKA) after operative management of tibial plateau fractures (TPFs) in older adults. Methods. This is a retrospective cohort study of 182 displaced TPFs in 180 patients aged ≥ 60 years, over a 12-year period with a minimum follow-up of one year. The mean age was 70.7 years (SD 7.7; 60 to 89), and 139/180 patients (77.2%) were female. Radiological assessment consisted of fracture classification; pre-existing knee osteoarthritis (OA); reduction quality; loss of reduction; and post-traumatic OA. Fracture depression was measured on CT, and the volume of defect estimated as half an oblate spheroid. Operative management, complications, reoperations, and mortality were recorded. Results. Nearly half of the fractures were Schatzker II AO B3.1 fractures (n = 85; 47%). Radiological knee OA was present at fracture in 59/182 TPFs (32.6%). Primary management was fixation in 174 (95.6%) and acute TKA in eight (4.4%). A total of 13 patients underwent late TKA (7.5%), most often within two years. By five years, 21/182 12% (95% confidence interval (CI) 6.0 to 16.7) had required TKA. Larger volume defects of greater depth on CT (median 15.9 mm vs 9.4 mm; p < 0.001) were significantly associated with TKA requirement. CT-measured joint depression of > 12.8 mm was associated with TKA requirement (area under the curve (AUC) 0.766; p = 0.001). Severe joint depression of > 15.5 mm (hazard ratio (HR) 6.15 (95% CI 2.60 to 14.55); p < 0.001) and pre-existing knee OA (HR 2.70 (95% CI 1.14 to 6.37); p = 0.024) were independently associated with TKA requirement. Where patients with severe joint depression of > 15.5 mm were managed with fixation, 11/25 ultimately required TKA. Conclusion. Overall, 12% of patients aged ≥ 60 years underwent TKA within five years of TPF. Severe joint depression and pre-existing knee arthritis were independent risk factors for both post-traumatic OA and TKA. These features should be investigated as potential indications for acute TKA in older adults with TPFs. Cite this article: Bone Joint J 2024;106-B(1):28–37


The Journal of Bone & Joint Surgery British Volume
Vol. 83-B, Issue 7 | Pages 1083 - 1083
1 Sep 2001
SAHNI V


The Journal of Bone & Joint Surgery British Volume
Vol. 83-B, Issue 4 | Pages 533 - 535
1 May 2001
Wade RH Moorcroft CI Thomas PBM

We have studied the progression of healing in 103 unstable fractures of the tibia. In 76 patients we removed the external fixator once the stiffness had reached 15 Nm/° in the sagittal plane. Deformity at the site of the fracture subsequently occurred in four patients. In a further 27, we measured stiffness in several planes and removed the fixator only when the stiffness reached 15 Nm/° in each. We found that stiffness in two orthogonal planes may differ widely (maximum difference 9.0 Nm/°, mean 4.1 Nm/°). There were no failures in the second group. We advocate that fracture stiffness be measured in two orthogonal planes when assessing tibial healing and suggest that values above 15 Nm/° in two planes give an indication that it is safe to remove the fixator.


The Journal of Bone & Joint Surgery British Volume
Vol. 77-B, Issue 1 | Pages 158 - 159
1 Jan 1995
Shenolikar A Hoddinott C


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXIX | Pages 52 - 52
1 Sep 2012
Mahmood A Malal JG Majeed SA
Full Access

Aim

The purpose of the study was to evaluate the results of Expert tibial nailing for distal tibial fractures.

Methods

All patients who had a distal third or distal end fracture of the tibia treated with the Expert tibial nail over a three year period at our institution were included in the study. A total of 44 distal tibial fractures in the same number of patients were treated with the nailing system. One patient died in the immediate post operative period from complications not directly related to the procedure and 3 were lost to follow up leaving a cohort of 40 patients for evaluation. 31 of the fractures were closed while the remaining 9 were open. The average age group of the cohort was 46.8 years with 26 males and 14 females.


The Journal of Bone & Joint Surgery British Volume
Vol. 73-B, Issue 1 | Pages 86 - 87
1 Jan 1991
Salam A Eyres K Cleary J el-Sayed H

Sixty closed fractures of the tibia were treated by open reduction and internal fixation with plates and screws. Half the operations were performed with a thigh tourniquet and half without. In the tourniquet group, there were six cases with erythema and induration of the wound; in the other group there were no such complications. Despite negative bacterial cultures, superficial infection of the inflamed wounds was suspected. It is suggested that a tourniquet may predispose tissues to infection, and its use is not recommended during operations for internal fixation of the tibia.


The Journal of Bone & Joint Surgery British Volume
Vol. 69-B, Issue 1 | Pages 56 - 56
1 Jan 1987
de Souza L


Bone & Joint Research
Vol. 10, Issue 7 | Pages 380 - 387
5 Jul 2021
Shen J Sun D Fu J Wang S Wang X Xie Z

Aims. In contrast to operations performed for other fractures, there is a high incidence rate of surgical site infection (SSI) post-open reduction and internal fixation (ORIF) done for tibial plateau fractures (TPFs). This study investigates the effect of induced membrane technique combined with internal fixation for managing SSI in TPF patients who underwent ORIF. Methods. From April 2013 to May 2017, 46 consecutive patients with SSI post-ORIF for TPFs were managed in our centre with an induced membrane technique. Of these, 35 patients were included for this study, with data analyzed in a retrospective manner. Results. All participants were monitored for a mean of 36 months (24 to 62). None were subjected to amputations. A total of 21 patients underwent two-stage surgeries (Group A), with 14 patients who did not receive second-stage surgery (Group B). Group A did not experience infection recurrence, and no implant or cement spacer loosening was noted in Group B for at least 24 months of follow-up. No significant difference was noted in the Lower Extremity Functional Scale (LEFS) and the Hospital for Special Surgery Knee Score (HSS) between the two groups. The clinical healing time was significantly shorter in Group B (p<0.001). Those with longer duration of infection had poorer functional status (p<0.001). Conclusion. Management of SSI post-ORIF for TPF with induced membrane technique combined with internal fixation represents a feasible mode of treatment with satisfactory outcomes in terms of infection control and functional recovery. Cite this article: Bone Joint Res 2021;10(7):380–387


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_6 | Pages 5 - 5
20 Mar 2023
Gupta S Sadczuk D Riddoch F Oliver W Davidson E White TO Keating JF Scott CEH
Full Access

We aimed to determine the rate of and risk factors for post-traumatic osteoarthritis (PTOA) and total knee arthroplasty (TKA) requirement after operative management of tibial plateau fractures (TPF) in older adults. We conducted a retrospective cohort study of 182 operatively managed TPFs in 180 patients ≥60 years old over a 12-year period with minimum follow up 1 year. Data including patient demographics, clinical frailty scores, mechanism of injury, management, reoperation and mortality were recorded. Radiographs were reviewed for: Schatzker classification; pre-existing knee osteoarthritis (KOA); severe joint depression >15mm; and development of PTOA. Kaplan Meier survival analysis was performed. Regression analysis was used to identify risk factors for radiographic indication for TKA and actual TKA. Forty-seven percent were Schatzker II fractures. Radiographic KOA was present at fracture in 32.6%. Fracture fixation was performed in 95.6% cases and acute TKA in 4.4%. Thirteen patients underwent late TKA (7.5%). At five-years, 11.8% (6.0-16.7 95% CI) had required TKA and 20.9% (14.4-27.4 95% CI) had a radiographic indication for TKA. Severe joint depression and pre-existing KOA were associated with worse survival for endpoints radiographic indication for TKA and actual TKA. Severe joint depression (HR 2.49(1.35-4.61 95% CI), p=0.004), pre-existing KOA (HR 2.23(1.17-4.23), p=0.015) and inflammatory arthropathy (HR 2.4(1.04-5.53), p=0.039) were independently associated with radiographic indication for TKA. In conclusion, severe joint depression and pre-existing arthritis are independent risk factors for both severe PTOA and TKA after TPFs in older adults. These features should be considered as an indication for primary management with acute TKA


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_16 | Pages 40 - 40
1 Apr 2013
Paetzold R Spiegl U Wurster M Augat P Gutsfeld P Gonschorek O Buehren V
Full Access

Alpine ski sports changed rapidly in the last decade. Complex fractures of the proximal tibia, typically seen in high energy trauma, has been seen more frequently and more often related to alpine skiing.

The aim of our study was to identify reasons for proximal tibia fracture in alpine skiing and observe the outcome.

All patients with proximal tibia fractures related to alpine skiing, which were treated in our two trauma centers were included. The patients received a questionnaire at the emergency department, dealing with accident details and the skiing habits. The fractures were classified according to the AO fracture classification scheme. The follow up was performed at least one year after trauma with the Lysholm, the Tegner activity, as well as the WOMAC VAS Score.

Between 2007 and 2010 a total of 188 patients with proximal tibia fractures caused by alpine skiing were treated. 43 patients had a type A, 96 patients a type B and 49 a type C injury. The incidence was increasing over the period continuously. The main trauma mechanism was an accident without a third party involvement with an increased rotational and axial compression impact. All outcome scores were related to fracture severity with significant worse results for the type C fractures.

In conclusion, proximal tibia fractures are an increasing and serious injury during alpine skiing. Further technical progress in skiing material should focus on these knee injuries in future.


The Journal of Bone & Joint Surgery British Volume
Vol. 80-B, Issue 3 | Pages 557 - 557
1 May 1998
MORAN CG BROWNSON P


The Journal of Bone & Joint Surgery British Volume
Vol. 69-B, Issue 3 | Pages 482 - 482
1 May 1987
Brougham D Nicol R


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_I | Pages 13 - 13
1 Jan 2011
Bosman H Mewton J Parsons B Bannister G
Full Access

Tibial shaft fracture occurs commonly in the young active population with high demands. Tibial fracture is potentially life changing. There are no published studies with long-term follow-up to provide accurate prognostic information regarding return to leisure activities, employment and driving. We aim to define the patient demographic and mechanism of injury and quantify the time period following tibial shaft fracture to return to sport and sporting level achieved at long-term follow-up. A retrospective multi-centre study was performed. Data collection was by questionnaire including Tegner activity scale score for sporting level and closed questioning on employment and driving. Ninety-three patients were recruited with an average 46 month (18–64mo) follow-up period. Patients were predominantly male (77%) with a median age at injury of 37 years. Road traffic accidents were responsible for 43% of injuries; sport 31%; falls 25% and assault 1%. High energy mechanisms accounted for 49% of injuries Seventy-eight percent of patients felt that prognostic information given at the time of injury was inaccurate. At follow-up, only 31% had regained their original level of sporting ability. Median Tegner score prior to injury score was 5 and at 18 months the mean score fell by 1.85. Patients sustaining high energy injuries were worst affected, dropping an average of 2.13 compared to low energy mechanisms with an average fall of 1.35 on the Tegner scale (p=0.503). High demand patients had a greater reduction in functional outcome, with a fall of 0.8 for patients with pre-injury activity level of 1–3 compared to the fall of 2.6 on the scale for more active patients scoring 7–9 pre-injury. Tibial fracture can result in significant long-term morbidity. Patients sustaining high energy injuries and high demand patients have significantly worse outcome. Patients are unlikely to achieve their pre-injury level of sporting activity at 2 years


The Journal of Bone & Joint Surgery British Volume
Vol. 73-B, Issue 4 | Pages 654 - 659
1 Jul 1991
Kenwright J Richardson J Cunningham J White S Goodship A Adams M Magnussen P Newman J

Diaphyseal fractures of the tibia in 80 patients were treated by external skeletal fixation using a unilateral frame, either in a fixed mode or in a mode which allowed the application of a small amount of predominantly axial micromovement. Patients were allocated to each regime by random selection. Fracture healing was assessed clinically, radiologically and by measurement of the mechanical stiffness of the fracture. Both clinical and mechanical healing were enhanced in the group subjected to micromovement, compared to those treated with frames in a fixed mode possessing an overall stiffness similar to that of others in common clinical use. The differences in healing time were statistically significant and independently related to the treatment method. There was no difference in complication rates between treatment groups.


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_IV | Pages 574 - 574
1 Nov 2011
Simunovic N
Full Access

Purpose: The purpose of this study was to evaluate how outcome assessment committees of various sizes, and the biases and personalities of its members, potentially impact a trial’s results.

Method: We conducted a retrospective analysis of the available individual and consensus data from an adjudication committee in a multinational trial (the SPRINT trial) of fracture fixation alternatives. The trial committee members included six members (5 surgeons, 1 methodologist) who independently determined the outcome of reoperation, and any discordant cases were discussed in the committee until a consensus was achieved. We described the pattern of agreement among adjudicators, modeled the adjudication process, and predicted the results if a smaller committee had been used. We also tested for adjudicator biases based upon their preferences for reamed or unreamed intramedullary nails, the presence of a potentially dominant adjudicator, and evaluated the resource implications of reducing the size of an adjudication committee.

Results: Overall, committee member agreement was moderate (Kappa Free=0.6). We found that reducing the number of adjudicators from six to three would have changed the consensus outcome in less than 15% of cases. Regardless of committee size, per-patient analyses also demonstrated very little change in the final study results across all fracture types or in the open fracture subgroup. Results from the original SPRINT adjudication indicated a significant decrease in the rate of reoperations associated with reamed intramedullary nailing among patients with closed fractures (relative risk 0.65; 95% confidence interval 0.46 to 0.93; p=0.02). Under the model, in committee sizes of three or less persons, these estimates of treatment effect were no longer significant. There was a significant difference between adjudicators with respect to the number of times their independent decision was in the minority but nevertheless became the final consensus decision (p=0.046), suggesting a dominant adjudicator was present in the committee. There were large predicted savings in cost and time with a reduced committee size.

Conclusion: In this study, smaller committees (i.e., four or five rather than six adjudicators) would likely have produced similar results, substantially reducing costs of research.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXIII | Pages 132 - 132
1 May 2012
Yanuarso O
Full Access

The treatment of fracture accompanied with bone defect remains a challenge in skeletal surgery. For bone defect, we have to give a material to support healing process. Some material is allograft given at second to sixth weeks to avoid osteoclastic activity. We try to give primary allograft and to prevent osteoclastic activity we use risedronat. Risedronate (Actonel(r)) is one of bisphosphonate group that decrease the turnover of the bone by activating apoptosis of osteoclast and increasing osteoblast activity. The aim of this paper is to evaluate radiologically and histologically result for the effect of the bone healing process for a fracture associated with bone defect which treated by a combination of fresh frozen allograft and risedronate (Actonel(r)).

The design is an experimental study, Post Test Only Control Group Design, using adult male white rats spraque-dawley. Right open tibial osteotomies to create bone defect are performed surgically and put Kirschner wire as intramedularry fixation. Rats are divided into four groups, with six samples in each group. Group one with bone defect in 2 mm, group two with bone defect 2 mm and put fresh frozen allograft, group three with bone defect 2 mm and put fresh frozen allograft and given Actonel(r) 350g a week for two first week, and group four with bone defect 2 mm and put fresh frozen allograft and given Actonel(r) 350g a week for six week. Six weeks after implantation, the animals were sacrificed, and the tibia were evaluated by radiological and histological studies.

Radiologically, there are significant different of relative bone healing result between ungiven risedronat group (group one and two) and given risedronat group (group three and four) (Kolmogorof smirnov test). Histological results by one way anova shows varians test was p = 0,168 (p > 0,05). Anova test was p = 0,000 (p < 0,05), post hoc Turkey HSD there was not significant different between group one and group two p = 0,969, between group one dan group four p = 0,634 (p > 0,05), between group two dan group four p = 0,634 (p > 0,05); a significant different between group one and group three p = p = 0,000 (p<0,05) between group two and group three p = 0,01 (p < 0,05), and group three and group four p=0,004 (p < 0,05)

Risedronate (Actonel(r)) influence the healing process of two mm bone defect radiologically. By histologically, two first weeks given of risedronate at group three have a better result than groups one, two and four.


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 4 | Pages 562 - 562
1 Apr 2007
KURUP HV


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 10 | Pages 1351 - 1360
1 Oct 2006
Rajasekaran S Babu JN Dheenadhayalan J Shetty AP Sundararajan SR Kumar M Rajasabapathy S

Limb-injury severity scores are designed to assess orthopaedic and vascular injuries. In Gustilo type-IIIA and type-IIIB injuries they have poor sensitivity and specificity to predict salvage or outcome.

We have designed a trauma score to grade the severity of injury to the covering tissues, the bones and the functional tissues, grading the three components from one to five. Seven comorbid conditions known to influence the management and prognosis have been given a score of two each. The score was validated in 109 consecutive open injuries of the tibia, 42 type-IIIA and 67 type-IIIB. The total score was used to assess the possibilities of salvage and the outcome was measured by dividing the injuries into four groups according to their scores as follows: group I scored less than 5, group II 6 to 10, group III 11 to 15 and group IV 16 or more.

A score of 14 to indicate amputation had the highest sensitivity and specificity. Our trauma score compared favourably with the Mangled Extremity Severity score in sensitivity (98% and 99%), specificity (100% and 17%), positive predictive value (100% and 97.5%) and negative predictive value (70% and 50%), respectively. A receiver-operating characteristic curve constructed for 67 type-IIIB injuries to assess the efficiency of the scores to predict salvage, showed that the area under the curve for this score was better (0.988 (± 0.013 sem)) than the Mangled Extremity Severity score (0.938 (± 0.039 sem)). All limbs in group IV and one in group III underwent amputation. Of the salvaged limbs, there was a significant difference in the three groups for the requirement of a flap for wound cover, the time to union, the number of surgical procedures required, the total days as an in-patient and the incidence of deep infection (p < 0.001 for all). The individual scores for covering and functional tissues were also found to offer specific guidelines in the management of these complex injuries.

The scoring system was found to be simple in application and reliable in prognosis for both limb-salvage and outcome measures in type-IIIA and type-IIIB open injuries of the tibia.


The Journal of Bone & Joint Surgery British Volume
Vol. 74-B, Issue 5 | Pages 673 - 677
1 Sep 1992
Ashcroft G Evans N Roeda D Dodd M Mallard Porter R Smith F

The quantification of local bone blood flow in man has not previously been possible, despite its importance in the study of normal and pathological bone. We report the use of positron emission tomography, using 15O-labelled water, to measure bone blood flow in patients with closed unilateral fractures of the tibia. We compared fractured and unfractured limbs; alterations in blood flow paralleled those found in animal models. There was increased tibial blood flow at the fracture site as early as 24 hours after fracture, reaching up to 14 times that in the normal limb at two weeks. Blood flow increase was less in displaced than in undisplaced fractures. The muscle to bone ratios of blood flow were similar to those in previous animal work using other techniques. Positron emission tomography will allow study of human bone blood flow in vivo in a wide variety of pathological conditions.


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 11 | Pages 1563 - 1567
1 Nov 2010
Parmaksizoglu F Koprulu AS Unal MB Cansu E

We present the results of 13 patients who suffered severe injuries to the lower leg. Five sustained a traumatic amputation and eight a Gustilo-Anderson type IIIC open fracture. All were treated with debridement, acute shortening and stabilisation of the fracture and vascular reconstruction. Further treatment involved restoration of tibial length by callus distraction through the distal or proximal metaphysis, which was commenced soon after the soft tissues had healed (n = 8) or delayed until union of the fracture (n = 5).

All patients were male with a mean age of 28.4 years (17 to 44), and had sustained injury to the leg only. Chen grade II functional status was achieved in all patients. Although the number of patients treated with each strategy was limited, there was no obvious disadvantage in the early lengthening programme, which was completed more quickly.


The Journal of Bone & Joint Surgery British Volume
Vol. 63-B, Issue 2 | Pages 185 - 189
1 May 1981
Dekel S Lenthall G Francis M

The release of prostaglandins E and F from the tibiae of rabbits and the surrounding muscle in vitro after fracture and pinning, or pinning alone, has been compared to the release from unoperated tissues. The fractured tibiae released significantly more prostaglandins E and F than the control tibiae three to 14 days after operation. The pinned tibiae also released more of the two prostaglandins, although this was significant only after 14 days. Consequently it was only around the third day that the fractured tibiae released significantly more prostaglandin E than the tibiae which had been pinned, but not fractured. Similar results were obtained for the release from the muscles surrounding the tibiae. Prostaglandins are important mediators of inflammation as well as potent stimulators of bone resorption. Their increased formation in response to fracture and pinning may stimulate the vascular changes, bone resorption and the proliferation of osteogenic cells observed after trauma to bone.


The Journal of Bone & Joint Surgery British Volume
Vol. 76-B, Issue 3 | Pages 488 - 490
1 May 1994
Vangsness C Ghaderi B Hohl M Moore T

We examined 36 consecutive patients with closed tibial plateau fractures under anaesthesia and by diagnostic and operative arthroscopy before treating them by closed or open reduction and internal fixation. Following the principle of Hohl (1967) (Fig. 1) there were 9 minimally displaced fractures (type I), 6 with local depression (type II), 13 with split depression (type III), 7 with total condylar depression (type IV), and one bicondylar comminuted upper tibial fracture (type V). Seventeen (47%) of knees were found to have associated meniscal injuries which required surgical treatment; five repairs and 12 partial meniscectomies. Neither the type of plateau fracture nor the presence or absence of ligament injury correlated with meniscal tear. There were no intraoperative or postoperative complications from arthroscopy


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XVIII | Pages 38 - 38
1 May 2012
Savaridas T Wallace R Dawson S Simpson A
Full Access

The effect of bisphosphonates on the mechanical properties of the uninjured contra-lateral cortical bone during fracture healing is poorly reported. There remains conflicting evidence with regards the effect of bisphosphonate therapy on cortical bone strength. We assessed the effect of nine weeks of Ibandronate therapy, in a dose known to preserve cancellous bone BMD and strength, on the mechanical properties of the uninjured rat tibial diaphyses using a standardised model of tibial osteotomy and plate fixation. Skeletally mature ex-breeder rats were used. Stress at failure of the tibial diaphyses was measured by a four-point bending test using a custom made jig for rat tibiae. The mechanical strength was compared with radiographic measurements of bone density. Animals received daily subcutaneous injections. 11 rats received 1μg/kg Ibandronate (IBAN) daily and 17 rats received 1ml 0.9% Sodium Chloride (CONTROL) daily.

The IBAN group had a statistically significant, p=0.024, higher stress at failure 212.7 (±42.04) MPa compared to the CONTROL group 171.7 (±46.13)MPa. There was a positive correlation between the mechanical strength of bone and the radiological measure of bone density.

Osteopenia is known to occur following a fracture even in the contra-lateral limb. This study demonstrates that ibandronate therapy has no detrimental effect and may even increase the strength of uninjured cortical bone during the fracture healing process. The longer term effect of ibandronate on cortical bone especially in relation to the accumulation of mico-damage requires further study. Bisphosphonate effect on the uninjured limb needs to be considered when reporting proportional strength of fracture repair compared to the uninjured limb.


Orthopaedic Proceedings
Vol. 87-B, Issue SUPP_III | Pages 288 - 289
1 Sep 2005
Topliss C Jackson M Atkins R
Full Access

Introduction: Tibial pilon fractures are complex and difficult to manage. Results with extensile approaches, rigid internal fixation and bone grafting remain poor. Percutaneous treatment does not allow anatomic restoration. Current classifications are not helpful. Understanding the anatomy and behaviour of the fracture would allow development of logical algorithms for treatment. Method: We have analysed plain radiographs and CT scans in a consecutive series of 126 pilon fractures and have defined the fracture anatomy and developed a new classification. Results: There are six constant articular fragments: anterior, anterolateral (insertion of AITFL), medial, posterior, posterolateral (insertion of PITFL) and die-punch. Two main fracture families exist depending on the articular fracture pattern. T-type and V/Y-type fractures. A lateral disruption type fracture represents a further important group. An evolution of fracture is evident within the groups. T-type fractures tend to occur in varus and result from higher energy injuries in younger patients. V/Y-type fractures tend to occur in valgus and result from lower energy injuries in older patients. Conclusions: We have defined distinct articular fragments, allowing development of safe direct surgical exposures. Stabilisation of the tibial fracture with fine-wire fixators or plates may be employed. The Pathoanatomy could be used in optimal design of such plates. Defining the fracture types gives us a useful and reproducible classification of injury


The Journal of Bone & Joint Surgery British Volume
Vol. 66-B, Issue 1 | Pages 84 - 88
1 Jan 1984
Haines J Williams E Hargadon E Davies D

All tibial shaft fractures treated at one hospital during a five-year period were studied in a prospective trial. Ninety-one displaced fractures in adults were treated using a conservative policy that included early bone grafting when indicated. Sound bony union was obtained in all cases. Those that healed primarily took on average 16.3 weeks whereas the 24 per cent that required bone grafts took 35.1 weeks. The number of complications, most of which were minor, was considered acceptable. It is concluded that provided early bone grafting is performed when necessary, a basically conservative policy of treatment is satisfactory; bony union of all displaced tibial fractures is achieved in a reasonable period of time


The Journal of Bone & Joint Surgery British Volume
Vol. 75-B, Issue 6 | Pages 921 - 925
1 Nov 1993
Pell A Christie J Keating J Sutherland G

We performed transoesophageal echocardiography on 24 patients during reamed intramedullary nailing of 17 tibial and seven femoral fractures. In 14 patients there was only minimal evidence of emboli passing through the heart, but in six copious showers of small emboli (< 10 mm maximum dimension) were observed. In four other patients, there were also multiple large emboli (> 10 mm maximum dimension). Three of these patients developed fat embolism syndrome postoperatively and one died. Earlier nailing was associated with smaller quantities of emboli.


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 8 | Pages 1068 - 1072
1 Aug 2008
Kuklo TR Groth AT Anderson RC Frisch HM Islinger RB

This article has been retracted, an editorial will follow.