Abstract

We measured fracture stiffness in 212 patients with tibial fractures treated by external fixation. In the first 117 patients (group 1) the decision to remove the fixator and allow independent weight-bearing was made on clinical grounds. In the other 95 patients (group 2) the frames were removed when the fracture stiffness had reached 15 Nm/degree. In group 1 there were eight refractures and in group 2 there was none (p = 0.02, Fisher's exact test). The time to independent weight-bearing was longer in group 1 (median 24 weeks) than in group 2 (21.7 weeks, p = 0.02). The greater precision of our objective measurement was associated with a reduction in refracture rate and in the time taken to achieve independent weight-bearing. We consider that a stiffness of 15 Nm/degree in the sagittal plane provides a useful definition of union of tibial fractures.