header advert
You currently have no access to view or download this content. Please log in with your institutional or personal account if you should have access to through either of these
The Bone & Joint Journal Logo

Receive monthly Table of Contents alerts from The Bone & Joint Journal

Comprehensive article alerts can be set up and managed through your account settings

View my account settings

Get Access locked padlock

The use of a tourniquet when plating tibial fractures



Download PDF

Abstract

Sixty closed fractures of the tibia were treated by open reduction and internal fixation with plates and screws. Half the operations were performed with a thigh tourniquet and half without. In the tourniquet group, there were six cases with erythema and induration of the wound; in the other group there were no such complications. Despite negative bacterial cultures, superficial infection of the inflamed wounds was suspected. It is suggested that a tourniquet may predispose tissues to infection, and its use is not recommended during operations for internal fixation of the tibia.

For access options please click here