Aims. To report the outcomes of patients with a fracture of the distal
Aims. Osteofibrous dysplasia (OFD) is a rare benign lesion predominantly affecting the
Intro. Calcium sulphate (CS) is a recent alternative for antibiotic elution in infected bones and joints. The purpose of this study is to evaluate the use of antibiotic impregnated calcium sulphate (AICS) beads in the management of infected
Objectives. This study aims to evaluate if micro-CT can work as a method for the 3D assessment and analysis of cancellous bone by comparing micro-CT with undecalcified histological sections in OVX rats. Methods. The mandible and
Aims. The aims of this study were to establish whether composite fixation
(rail-plate) decreases fixator time and related problems in the
management of patients with infected nonunion of
Aims. In this randomized study, we aimed to compare quality of regenerate in monolateral versus circular frame fixation in 30 patients with infected nonunion of
Congenital pseudarthrosis of the
Aims. This is a prospective randomised study which compares the radiological
and functional outcomes of ring and rail fixators in patients with
an infected gap (>
3 cm) nonunion of the
Stress shielding resulting in diminished bone
density following total knee replacement (TKR) may increase the
risk of migration and loosening of the prosthesis. This retrospective
study was designed to quantify the effects of the method of fixation
on peri-prosthetic
Aims. Unicompartmental and total knee arthroplasty (UKA and TKA) are successful treatments for osteoarthritis, but the solid metal implants disrupt the natural distribution of stress and strain which can lead to bone loss over time. This generates problems if the implant needs to be revised. This study investigates whether titanium lattice UKA and TKA implants can maintain natural load transfer in the proximal
Open
Introduction. Infected big gap non-union of femur and
Aims. This study aimed to identify the effect of anatomical tibial component (ATC) design on load distribution in the periprosthetic
Aims. To systematically review qualitative studies of patients with distal
This study aimed to investigate the outcomes of open
Aims. To describe outcome reporting variation and trends in non-pharmacological randomized clinical trials (RCTs) of distal
Aims. The proximal
Introduction: The Expert
Abstract. Objectives. Unicompartmental and total knee arthroplasty (UKA and TKA) are successful treatments for osteoarthritis, but monolithic implants disrupt the natural homeostasis of bone which leads to bone loss over time. This can cause problems if the implant needs to be revised. This study aimed to demonstrate that tibial implants made from titanium lattice could replace the tibial condyle surface while minimising disruption of the bone's natural mechanical loading environment. A secondary aim was to determine whether implants perform better if they replicate more closely bone's mechanical modulus, anisotropy and spatial heterogeneity. This study was conducted in a human cadaveric model. Methods. In a cadaveric model, UKA and TKA procedures were performed on 8 fresh-frozen knee specimens by a board-certified consultant orthopaedic surgeon, using tibial implants made from conventional monolithic material and titanium lattice structures. Stress at the bone-implant interfaces was measured with pressure film and compared to the native knee. Results. Titanium lattice implants were able to restore the mechanical environment seen in the native
Introduction. Correction of multiplanar bone deformities in children is indicated for prevention of secondary orthopaedic complications. Different problems related to surgical intervention were reported: non-union, delayed union, recurrent deformity, refracture, nerve palsy and pin tract infection. The aim of this study was to show the results of children femur and
Aims. The aim of this study was to report the results of three forms of reconstruction for patients with a ditsl
µCT images are commonly analysed to assess changes in bone density and architecture in preclinical murine models. Several platforms provide automated analysis of bone architecture parameters from volumetric regions of interest (ROI). However, segmentation of the regions of subchondral bone to create the volumetric ROIs remains a manual and time-consuming task. This study aimed to develop and evaluate automated pipelines for trabecular bone architecture analysis of mouse proximal
Aims. The modified Radiological Union Scale for
Abstract. Congenital posteromedial bowing of
Introduction. Bone transport and distraction osteogenesis have been shown to be an effective treatment for significant bone loss in the
Abstract. Introduction. Medial fix bearing unicompartmental knee replacement (UKR) designs are consider safe and effective implants with many registries data and big cohort series showing excellent survivorship and clinical outcome comparable to that reported for the most expensive and surgically challenging medial UKR mobile bearing designs. However, whether all polyethylene tibial components (all-poly) provided comparable results to metal-backed modular components during medial fix bearing UKR remains unclear. There have been previous suggestions that all-poly
Objectives. Open fracture classification systems are limited in their use. Our objective was to classify open
Introduction. Congenital posteromedial bowing of
Abstract. Approximately 20% of primary and revision Total Knee Arthroplasty (TKA) patients require multiple revisions, which are associated with poor survivorship, with worsening outcomes for subsequent revisions. For revision surgery, either endoprosthetic replacements or metaphyseal sleeves can be used for the repair, however, in cases of severe defects that are deemed “too severe” for reconstruction, endoprosthetic replacement of the affected area is recommended. However, endoprosthetic replacements have been associated with high complication rates (high incidence rates of prosthetic joint infection), while metaphyseal sleeves have a more acceptable complication profile and are therefore preferred. Despite this, no guidance exists as to the maximal limit of bone loss, which is acceptable for the use of metaphyseal sleeves to ensure sufficient axial and rotational stability. Therefore, this study assessed the effect of increasing bone loss on the primary stability of the metaphyseal sleeve in the proximal
Aims. Open fractures of the
Purpose. Addressing posterior tibial plateau fractures is increasingly recognized as an important prognostic factor for functional outcome. The treatment of posterior tibial plateau fractures is rather demanding and the implants are still standard, off-the-shelf implants. This emphasizes the need for a more thorough morphological study of the posterior tibial plateau, in order to treat these posterior fractures more adequately. We aimed to demonstrate anatomical variations of the
Aim. Differentiation of infected (INF) nonunion from aseptic (AS) nonunion is crucial for the choice of intra- and postoperative treatment. Preoperative diagnosis of infected nonunion is challenging, especially in case of low-grade infection lacking clinical signs of infection. Standard blood markers such as C-reactive protein or leucocyte count do not aid in preoperative diagnosis. Proteomic profiling has shown promising results for differentiation of numerous chronic disease states, and in this study was applied to preoperative blood samples of patients with nonunion in an attempt to identify potential biomarkers. Method. This prospective multicenter study enrolled patients undergoing revision surgery of femur or
Aims. Eight-plates are used to correct varus-valgus deformity (VVD) or limb-length discrepancy (LLD) in children and adolescents. It was reported that these implants might create a bony deformity within the knee joint by change of the roof angle (RA) after epiphysiodesis of the proximal
Aims. We retrospectively report our experience of managing 30 patients with a primary malignant tumour of the distal
Aims. Pin-site infection remains a significant problem for patients treated by external fixation. A randomized trial was undertaken to compare the weekly use of alcoholic chlorhexidine (CHX) for pin-site care with an emollient skin preparation in patients with a tibial fracture treated with a circular frame. Methods. Patients were randomized to use either 0.5% CHX or Dermol (DML) 500 emollient pin-site care. A skin biopsy was taken from the
Introduction and Objective. The geometry of the proximal
Aims. Many authors have reported a shorter treatment time when using trifocal bone transport (TFT) rather than bifocal bone transport (BFT) in the management of long segmental
Abstract. Introduction. Ankle arthritis is estimated to affect approximately 72 million people worldwide. Treatment options include fusion and total ankle replacement (TAR). Clinical performance of TAR is not as successful as other joint replacement and failure is poorly understood. Finite element analysis offers a method to assess the strain in bone implanted with a TAR. Higher strain has been associated with microfracture and alters the bone-implant interface. The aim of this study was to explore the influence of implant fixation on strain within the
Introduction. To determine the advantages and risks of plating after lengthening (PAL) of
Introduction: The addition of recombinant human bone morphogenetic protein-2 (rhBMP-2) showed significant reduction of secondary intervention, fracture healing time and infection rates compared with intramedullary nailing alone in open
We report the operative technique and results of a new method of central grafting for persistent nonunion of the tibial shaft. The operation is performed through a lateral approach, anterior to the fibula. Fresh autogenous bone from the iliac crest is used to form a central bridge between the
Background. The modern modular implants allow surgeons to combine different combinations of components within the same brand of which some may have completely different design. During 1999–2012 the same cemented femur component was used together with a cemented stemmed
Aims. Our intention was to investigate if the highly porous biological fixation surfaces of a new 3D-printed total knee arthroplasty (TKA) achieved adequate fixation of the tibial and patellar components to the underlying bone. Patients and Methods. A total of 29 patients undergoing primary TKA consented to participate in this prospective cohort study. All patients received a highly porous tibial baseplate and metal-backed patella. Patient-reported outcomes measures were recorded and implant migration was assessed using radiostereometric analysis. Results. Patient function significantly improved by three months postoperatively (p < 0.001). Mean difference in maximum total point motion between 12 and 24 months was 0.021 mm (-0.265 to 0.572) for the tibial implant and 0.089 mm (-0.337 to 0.758) for the patellar implant. The rate of tibial and patellar migration was largest over the first six postoperative weeks, with no changes in mean
We proposed the substitute anteroposterior (sAP) line of the
Introduction and Objective. Management of gap non-union of the
Despite multiple published reviews, the optimum method of correction and stabilisation of Blount's disease remains controversial. The purpose of this study is to evaluate the clinical and radiological outcomes of acute correction of late-onset tibial vara by percutaneous proximal tibial osteotomy with circular external fixation using two simple rings. This technique was developed to minimise cost in a context of limited resources. This study was conducted between 2016 and 2020. We retrospectively reviewed the clinical notes and radiographs of 30 patients (32tibiae) who had correction of late-onset
INTRODUCTION. Clinical studies have shown that the knee tends to experience laterally higher AP motion (posterior directed) than medially (Asano at al., 2001; Dennis et al., 2005; Hill et al., 2000; Moro Oka et al., 2007). Traditional posterior stabilized (PS) total knee arthroplasty (TKA) designs allow deep flexion stability and femoral rollback once cam/spine engagement occurs, however mechanical stability provided by tibial bearing conformity during early to mid-flexion is highly variable. In this study a computer knee model is used to compare AP kinematics in PS TKA designs while evaluating multiple sagittal
Bone turnover markers (BTMs) follow distinct trends after fractures and limited evidence suggests differential levels in BTMs in patients with delayed healing. The effect of vitamin D, and other factors that influence BTMs and fracture healing, is important to elucidate the use of BTMs as surrogates of fracture healing. We sought to determine whether BTMs can be used as early markers of delayed fracture healing, and the effect of vitamin D on BTM response after fracture. A total of 102 participants aged 18 to 50 years (median 28 years (interquartile range 23 to 35)), receiving an intramedullary nail for a tibial or femoral shaft fracture, were enrolled in a randomized controlled trial comparing vitamin D3 supplementation to placebo. Serum C-terminal telopeptide of type I collagen (CTX; bone resorption marker) and N-terminal propeptide of type I procollagen (P1NP; bone formation marker) were measured at baseline, six weeks, and 12 weeks post-injury. Clinical and radiological fracture healing was assessed at three months.Aims
Methods
Evaluation of the surgical approach and treatment outcomes in patients with chronic osteomyelitis of the
The aim of this study was to establish a reliable method for producing 3D reconstruction of sonographic callus. A cohort of ten closed tibial shaft fractures managed with intramedullary nailing underwent ultrasound scanning at two, six, and 12 weeks post-surgery. Ultrasound capture was performed using infrared tracking technology to map each image to a 3D lattice. Using echo intensity, semi-automated mapping was performed to produce an anatomical 3D representation of the fracture site. Two reviewers independently performed 3D reconstructions and kappa coefficient was used to determine agreement. A further validation study was undertaken with ten reviewers to estimate the clinical application of this imaging technique using the intraclass correlation coefficient (ICC).Aims
Methods
Introduction. This is a report of the outcome of management of congenital pseudoarthrosis of the
Purpose. To review the natural history of posteromedial bowing of the
Background. Total knee arthroplasty (TKA) overall is a very reliable, durable procedure. Biomechanical studies have suggested superior stress distribution in metal-backed tibial trays, however, these results have not been universally observed clinically. Currently, there is a paucity of information examining the survival and outcomes of all-polyethylene tibial components. Methods. We reviewed 31,939 patients undergoing a primary TKA over a 43-year period (1970–2013). There were 28,224 (88%) metal-backed and 3,715 (12%) all-polyethylene tibial components. The metal-backed and all-polyethylene groups had comparable demographics with respect to sex distribution (57% female for both) mean age (67 vs. 71 years), and mean BMI (31.6 vs. 31.1). Mean follow-up was 7 years (maximum 40 years). Results. The purpose of this investigation was to analyze the outcomes of all-polyethylene compared to metal-backed components in TKA and to determine (1) is there a difference in overall survival? All polyethylene tibial components had improved survivorship (P<0.0001) and metal-backed
Background. Total knee arthroplasty (TKA) overall is a very reliable, durable procedure. Biomechanical studies have suggested superior stress distribution in metal-backed tibial trays, however, these results have not been universally observed clinically. Currently, there is a paucity of information examining the survival and outcomes of all-polyethylene tibial components. Methods. We reviewed 31,939 patients undergoing a primary TKA over a 43-year period (1970–2013). There were 28,224 (88%) metal-backed and 3,715 (12%) all-polyethylene tibial components. The metal-backed and all-polyethylene groups had comparable demographics with respect to sex distribution (57% female for both), mean age (67 vs. 71 years), and mean BMI (31.6 vs. 31.1). Mean follow-up was 7 years (maximum 40 years). Results. The purpose of this investigation was to analyze the outcomes of all-polyethylene compared to metal-backed components in TKA and to determine: (1) is there a difference in overall survival? All-polyethylene tibial components had improved survivorship (P<0.0001) and metal-backed
Aims. Following the introduction of national standards in 2009, most
major paediatric trauma is now triaged to specialist units offering
combined orthopaedic and plastic surgical expertise. We investigated
the management of open
Abstract. Objectives. This study aids the control of remodelling and strain response in bone; providing a quantified map of apparent modulus and strength in the proximal
Over the past fifteen years, the average length of stay for total hip (THA) and total knee arthroplasty (TKA) has gradually decreased from several days to overnight. The most logical and safest next step is outpatient arthroplasty. Through the era of so-called minimally invasive surgery, perhaps the most intriguing advancements are not related to the surgery itself, but instead the areas of rapid recovery techniques and peri-operative protocols. Rapid recovery techniques and peri-operative protocols have been refined to allow for same-day discharge with improved outcomes. In addition to Rapid Recovery techniques for the clinical care of the outpatient, one critical component to same-day total knee arthroplasty is the efficient performance and simplicity of the procedure itself. Simplified instrumentation and elimination of modularity can provide that efficiency and simplicity. All polyethylene tibial components have been mostly supplanted by modular metal-backed designs in recent years. However, mounting evidence suggests that survivorship of TKA with an all-poly
Total knee replacement (TKA) is one of the most successful procedures in orthopaedic surgery. Although originally limited to more elderly and less active individuals, the inclusion criteria for TKA have changed, with ever younger, more active and heavier patients receiving TKA. This broadening of indications coincided with the widespread adoption of modular cemented and cementless TKA systems in the 1980's, and soon thereafter wear debris related osteolysis and associated prosthetic loosening became major modes of failure for TKA implants of all designs. Initially, tibial components were cemented all polyethylene monoblock constructs. Subsequent long-term follow-up studies of some of these implant designs have demonstrated excellent durability in survivorship studies out to twenty years. While aseptic loosening of these all polyethylene tibial components was a leading cause of failure in these implants, major polyethylene wear-related osteolysis around well-fixed implants was rarely (if ever) observed. Cemented metal-backed nonmodular tibial components were first introduced to allow for improved tibial load distribution and protection of the underlying (often osteoporotic) bone. Eventually, modularity between the polyethylene tibial component and the metal-backed tray was introduced in the mid-80s mainly to facilitate screw fixation for cementless implants. These designs also provided intraoperative versatility by allowing interchange of various polyethylene thicknesses, and also aided the addition of stems and wedges. Modular vs. All Polyethylene Tibial Components in Primary TKA: Kremers et al. reviewed 10,601 adult (>18 years) patients with 14,524 condylar type primary TKA procedures performed at our institution between 1/1/1988 and 12/31/2005 and examined factors effecting outcome. The mean age was 68.7 years and 55% were female. Over an average 9 years follow-up, a total of 865 revisions, including 252
Flexible intramedullary nailing is gaining popularity as an effective method of treating long-bone fractures in children. We retrospectively reviewed the records and radiographs of 56 unstable fractures of the
Introduction. Uncemented highly porous titanium implants have been shown to promote osseointegration, and may result in a durable construct for total knee arthroplasty (TKA). Given the mixed results of uncemented TKA, it is important to evaluate the early stability for this product. The objective of the following study was to use radiostereometric analysis (RSA) to assess early fixation of a highly porous tibial baseplate and metal backed patella. Methods. Twenty-seven patients (mean age 64 years, 30% female) undergoing primary TKA consented to participate in this prospective cohort study. All patients received a highly porous tibial baseplate, a metal backed patella and tantalum RSA bone markers. Implant migration was assessed using model-based RSA at 1.5, 3, 6, 12 and 24 months post-operative. Patient reported outcome measures were captured using the same follow-up schedule, and compared to pre-operative measures. Results. There were no adverse events affecting implant fixation, and no revisions. Patient function significantly improved by 3 months post-operation (p < 0.001). The highest rate of
Aims. Type IIIB open tibial fractures are devastating high-energy injuries. At initial debridement, the surgeon will often be faced with large bone fragments with tenuous, if any, soft-tissue attachments. Conventionally these are discarded to avoid infection. We aimed to determine if orthoplastic reconstruction using mechanically relevant devitalized bone (ORDB) was associated with an increased infection rate in type IIIB open tibial shaft fractures. Patient and Methods. This was a consecutive cohort study of 113 patients, who had sustained type IIIB fractures of the
In case when a cavity is detected in the place of a diagnosed osteomyelitis and when the location of the lesion is in the metaphyseal area, a revision can be done by an endoscopic method, using a standard arthroscopic device. This method was called as “medulloscopy”. In our paper we would like to introduce our first experiences with this method. We performed six surgeries of a chronic
How do we treat severe knee OA with bowing deformity of
Introduction and objectives. Intramedullary nailing is indicated to stabilization of
Purpose. Degenerative osteoarthritis of the knee usually shows arthritic change in the medial tibiofemoral joint with severe varus deformity. In TKA, the medial release technique is often used for achieving mediolateral balancing, but there is some disagreement regarding the importance of pursuing the perfect rectangular gaps. Our hypothesis is that the minimal release especially in MCL is beneficial regarding on retaining the physiological medial stability and knee kinematics, which leads to improved functional outcome. Therefore, the purpose of this study is to examine the thickness of the
Aims. This study describes the use of the Masquelet technique to treat
segmental
Nonunion of the
Open tibial fractures are limb-threatening injuries. While limb loss is rare in children, deep infection and nonunion rates of up to 15% and 8% are reported, respectively. We manage these injuries in a similar manner to those in adults, with a combined orthoplastic approach, often involving the use of vascularised free flaps. We report the orthopaedic and plastic surgical outcomes of a consecutive series of patients over a five-year period, which includes the largest cohort of free flaps for trauma in children to date. Data were extracted from medical records and databases for patients with an open tibial fracture aged < 16 years who presented between 1 May 2014 and 30 April 2019. Patients who were transferred from elsewhere were excluded, yielding 44 open fractures in 43 patients, with a minimum follow-up of one year. Management was reviewed from the time of injury to discharge. Primary outcome measures were the rate of deep infection, time to union, and the Modified Enneking score.Aims
Methods
Background: Total knee arthroplasty (TKA) overall is a very reliable, durable procedure. Biomechanical studies have suggested superior stress distribution in metal-backed tibial trays, however, these results have not been universally observed clinically. Currently there is a paucity of information examining the survival and outcomes of all-polyethylene tibial components. Methods: We reviewed 31,939 patients undergoing a primary TKA over a 43-year period (1970–2013). There were 28,224 (88%) metal-backed and 3,715 (12%) all-polyethylene tibial components. The metal-backed and all-polyethylene groups had comparable demographics with respect to sex distribution (57% female for both) mean age (67 vs. 71 years), and mean BMI (31.6 vs. 31.1). Mean follow-up was 7 years (maximum 40 years). Results: The purpose of this investigation was to analyze the outcomes of all-polyethylene compared to metal-backed components in TKA and to determine (1) is there a difference in overall survival? All-polyethylene tibial components had improved survivorship (P<0.0001) and metal-backed
A nine-year-old girl presented with a four-year history of progressive bowing of the left
Objectives. Proximal tibial fracture is one of the most common postoperative complications of unilateral knee arthroplasty (UKA). The objective of the present study is to investigate the risk factors of these fractures, occurred after UKA in our facility. Method. We performed 314 UKAs between May 2006 and December 2013. All cases were done using Oxford UKA. Proximal tibial fractures were observed in 5 cases. 4 cases were female and 1 case was male, and the age at the operation ranged from 73 to 90. All cases were osteoarthritis. 4 cases were diagnosed as stress fracture with minimum displacement, and 1 case was fracture with displacement. We investigated the risk factors of the tibial fracture among those 5 cases. Low bone mineral density(BMD), the presence of medial tibial cortex pinhole, excessive vertical cut, and adjacence of keel and posterior
There is no question that excellent long-term results have been demonstrated with all-polyethylene tibial components. Moreover, improvements in polyethylene to increase wear resistance, maintain mechanical strength, and improve oxidative resistance lend even greater credence to the use of an all-polyethylene tibial component. There are several issues of concern. In revision knee replacement for reasons such as patellofemoral problems where the components are otherwise ideal, the arthrotomy performed during the revision usually creates a slight laxity requiring a thicker polyethylene or even a different tibial conformity. With an all-polyethylene
Although proximal
Introduction. Various implant designs and bearing surfaces are used in TKR. The use of All Poly
Aim. Infected segmental defects are one of the most feared complications of open tibial fractures. This may be due to prolonged treatment time, permanent functional deficits and high reinfection and non-union rates. Distraction osteogenesis techniques such as Ilizarov acute shortening with bifocal relengthening (ASR) and bone transport (BT) are effective surgical treatment options in the
Aim. To evaluate the results and complications of bone transport in the treatment of massive
Although osteoporosis reduces overall bone mass causing bone fragility, our recent studies have shown that bone tissue composition is altered at the microscopic level, which is undetectable by conventional diagnostic techniques (DEXA) but may contribute to bone fracture. However, the time sequence of changes in bone microarchitecture, mechanical environment and mineral distribution are not yet fully understood. This study quantified the longitudinal effects of estrogen deficiency on the trabecular microarchitecture and mineral distribution in the
Introduction: Congenital pseudoarthrosis is one of the greatest challenges of pediatric orthopedic practice. Treatment measures and literature addressing this condition are numerous reflecting the difficulty in management. The aim of successful treatment is to achieve length, union and normal axis of the involved leg. A method of treatment is described whereby the affected
Two big problems exist with the all polyethylene cemented tibial component; the polyethylene and the cement. The polyethylene is too weak and flexible to bear high tibial load, so it deforms and loosens. The interface stresses are too high when two flexible structures are poorly bonded and heavily loaded. Modularity between the polyethylene tibial component and the metal-backed tray was introduced in the mid-80's for versatility and to facilitate screw fixation for cementless implants. These designs allow exchange of various polyethylene thicknesses, and aids the addition of stems and wedges. Other advantages include the reduction of inventory, and the potential for isolated tibial polyethylene exchanges as a simpler revision procedure. Several studies have documented the high failure rate of isolated polyethylene exchange procedures, because technical problems related to the original components are left uncorrected. However, revision for wear is the simplest revision ever!. Since the late 1980's the phenomena of polyethylene wear and osteolysis have been observed much more frequently when compared with earlier eras. The reasons for this increased prevalence of synovitis, progressive osteolysis, and severe polyethylene wear remain unclear. There is some association with the widespread use of both cementless and cemented modular tibial designs. Improved polyethylene attachment is the answer even if a screw, a wire, or a pin is needed. Do not abandon the modular
Osteoarthritic (OA) changes to the bone morphology of the proximal
The use of recombinant human bone morphogenetic protein-2 (rhBMP-2) for the treatment of congenital pseudarthrosis of the
Purpose: To evaluate the efficacy of intramedullary nailing for the treatment of the fractures of the proximal quarter of the
Morbid obesity and its association with obstructive sleep apnoea syndrome have been increasingly recognised in children. Orthopaedic surgeons are often the primary medical contact for older children with
Objectives. Little biomechanical information is available about kinematically aligned (KA) total knee arthroplasty (TKA). The purpose of this study was to simulate the kinematics and kinetics after KA TKA and mechanically aligned (MA) TKA with four different limb alignments. Materials and Methods. Bone models were constructed from one volunteer (normal) and three patients with three different knee deformities (slight, moderate and severe varus). A dynamic musculoskeletal modelling system was used to analyse the kinematics and the tibiofemoral contact force. The contact stress on the tibial insert, and the stress to the resection surface and medial tibial cortex were examined by using finite element analysis. Results. In all bone models, posterior translation on the lateral side and external rotation in the KA TKA models were greater than in the MA TKA models. The tibiofemoral force at the medial side was increased in the moderate and severe varus models with KA TKA. In the severe varus model with KA TKA, the contact stress on the tibial insert and the stress to the resection surface and to the medial tibial cortex were increased by 41.5%, 32.2% and 53.7%, respectively, compared with MA TKA, and the bone strain at the medial side was highest among all models. Conclusion. Near normal kinematics was observed in KA TKA. However, KA TKA increased the contact force, stress and bone strain at the medial side for moderate and severe varus knee models. The application of KA TKA for severe varus knees may be inadequate. Cite this article: S. Nakamura, Y. Tian, Y. Tanaka, S. Kuriyama, H. Ito, M. Furu, S. Matsuda. The effects of kinematically aligned total knee arthroplasty on stress at the medial
Introduction. Total Knee Replacement (TKR) is a highly effective treatment providing pain relief and improved function to patients experiencing advanced stage osteoarthritis. Tray fit or bone coverage is a critical design feature for both cemented and cementless designs affecting stability, load transfer and potential for infection. Many authors have attempted to characterise the relationship between the profile of the proximal
Introduction. Precise implant matching with a resected bony surface is a crucial issue to ensure a successful total knee arthroplasty (TKA). Extremely undersized or oversized components should be avoided. Therefore, we should measure the exact anthropometric data of the resected bony surface preoperatively or intraoperatively. The purpose of this study was to intraoperatively analyze the exact anthropometric proximal tibial data of Japanese patients undergoing TKA and correlate these measurements to the dimensions of current prosthetic systems. Patients and Methods. Three hundred and seventy-three knees in 299 Japanese patients were included in this study. There were 246 women and 53 men with a mean age of 74 (range: 63–85) years. All TKAs were performed by 3 senior surgeons (TS, AK, and NM). The bone cut in the proximal
The aim of this study was to assess the incidence of fibula non-union in patients undergoing distraction osteogenesis, and the incidence of symptoms following this. A consecutive series of 58 patients undergoing distraction osteogenesis at a tertiary centre under a single surgeon were included. Data was collected prospectively. Plain radiographs were reviewed retrospectively by a blinded reviewer. Union was defined as the presence of bridging callous on two views. There were 58 distraction procedures performed. The mean age was 37.2 years (range 16.0 to 80.6). There were 36 males and 22 females. The mean follow-up was 23.4 months (4–70 months). 9 (15.5%) went onto non-union at frame removal. 3 (33.3%) of the 9 fibulas that did not unite developed symptoms. 2 (66.7%) of these required surgery in the form of fibula plating. Both of these patient's symptoms resolved following surgery. 3 (33.3%) of the 9 non-united fibulas also had tibial non-union compared to 1 of the 49 where the fibula united. There was no association between location of fibula osteotomy and development of non-union. 35 fibula osteotomies were performed in the third quarter. Of the fibulas that united, the mean fibula lengthening was 9.25 mm (range 1.2–27.8 mm). In the fibulas that went onto non-union the mean lengthening was 23.66 mm (range 5.1–51.5 mm) (P = 0.004). 54 (93.1%) of the
Background: Total knee arthroplasty (TKA) overall is a very reliable, durable procedure. Biomechanical studies have suggested superior stress distribution in metal-backed tibial trays, however, these results have not been universally observed clinically. Currently, there is a paucity of information examining the survival and outcomes of all-polyethylene tibial components. Methods: We reviewed 31,939 patients undergoing a primary TKA over a 43-year period (1970–2013). There were 28,224 (88%) metal-backed and 3,715 (12%) all-polyethylene tibial components. The metal-backed and all-polyethylene groups had comparable demographics with respect to sex distribution (57% female for both) mean age (67 vs. 71 years), and mean BMI (31.6 vs. 31.1). Mean follow-up was 7 years (maximum 40 years). Results: The purpose of this investigation was to analyze the outcomes of all-polyethylene compared to metal backed components in TKA and to determine (1) is there a difference in overall survival? All-polyethylene tibial components had improved survivorship (P<0.0001) and metal backed
Purpose of the Study. A cooled, side cutting burr designed for use in adult foot surgery has been used as a primary bone cutting device in children to facilitate a truly percutaneous method of performing osteotomies. Stabilisation of the femur was using a percutaneous locked nail and for the
Aim. In patients with bone sarcoma, placing mega prostheses in the proximal
We evaluated the efficacy of using the expandable nail for treating non-union and malunion of the tibial and femoral shafts. Records of 20 patients were retrospectively reviewed: 12 had femoral non-union, 7 had tibial non-union, and one had tibial malunion. The bones underwent reaming and the largest possible nail sizes were inserted during reoperation. The mean age of the patients was 35 years (26-49) in the
Fracture of the
1. Three cases of infantile pseudarthrosis of the
Congenital unilateral anterolateral tibial bowing in combination with a bifid ipsilateral great toe is a very rare deformity which resembles the anterolateral tibial bowing that occurs in association with congenital pseudarthrosis of the
Aim: We present our experience of the treatment of the ipsilateral fractures of the femur and
The term Volkmann’s triangle for the avulsed posterior edge of the
Introduction. We investigated the usefulness of flap surgery for Gustilo type IIIB and C severe open fracture of the
A percutaneous supramalleolar osteotomy with multiple drill holes and closed osteoclasis was used to correct rotational deformities of the
There are several case reports or small series of stress tibial fracture around the OA knees in literature. Our study goes on 10 tibial stress fracture in 9 patients. All of the fractures have been distal to proximal tibial methaphysis. 8 of them have been in mid shaft or proximal of mid
Fourteen cases of pseudarthrosis of the