REFERENCING THE SUBSTITUTE ANTEROPOSTERIOR LINE OF THE TIBIA IMPROVES ROTATIONAL ALIGNMENT OF THE COMPONENTS IN MEDIAL UNICOMPARTMENTAL KNEE ARTHROPLASTY

The Canadian Orthopaedic Association (COA) and The International Combined Orthopaedic Research Societies (ICORS) Meeting, Montreal, Canada, June 2019.



Abstract

We proposed the substitute anteroposterior (sAP) line of the tibia for medial unicompartmental knee arthroplasty (UKA), which connects the medial border of the patellar tendon at the articular surface level and the medial intercondylar tubercle of the tibia. However, it has not been shown that referencing this line improves the rotational alignment of the components. Therefore, in this study, we investigated whether the tibial component could be implanted perpendicular to the SEA by referencing the sAP line and whether referencing the sAP line could reduce the rotational mismatch between the femoral and the tibial components.

Postoperative computed tomography datasets from 60 lower limbs in 57 Japanese patients with medial UKA were used. Among these, 30 knees were operated using the sAP line for AP reference and other 30 knees using the medial intercondylar ridge (MIR) line. First, the angle between the AP orientation of the tibial component and the surgical epicondylar axis (SEA) was measured. Then, the rotational mismatch angle between the components was measured.

The tibial and femoral components placed referencing the sAP line were externally rotated 90.7°±3.2° and 91°±7.7° relative to the SEA, respectively, those referencing the MIR line were 94.9°±8.5° and 91.2°±7.7°, respectively. When referencing the sAP line, the orientation of the component was more perpendicular to the SEA (Student t-test, unpaired, P = .016) and rotational variability of the tibial component was significantly smaller (F test, P < 0 .0001). The rotational mismatch angle when referencing the sAP line and the MIR line was 0.3°±8.3°and −3.8°±6.7°, respectively. Referencing the sAP line significantly reduced the rotational mismatch between the components (Student t-test, unpaired, P = .045).

Referencing the sAP line in the medial UKA may be useful to determine the AP orientation of the tibial component.