header advert
Results 301 - 350 of 984
Results per page:
Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_6 | Pages 18 - 18
1 Apr 2014
Towriss C Baxter G Yasso S James S Jones A Howes J Davies P Ahuja S
Full Access

Aim:

To measure truncal parameters for patients treated with growing rod systems for early onset scoliosis (EOS).

Methods:

44 patients underwent growth rod surgery for EOS between 1999 and 2013 (24 females and 20 males). 27 patients had idiopathic scoliosis, 13 congenital, 3 syndromic and 1 neuromuscular. 26 patients had Paediatric Isola, 8 had Paediatric Expedium, 4 had dual growth rods with domino's and 9 each had VEPTR and MAGEC rods systems. Medical records and radiographs were analysed. Cobb angle, T1-T12 and T1-S1 length, coronal and sagittal balance, apical vertical translation (AVT), space available for the lung (SAL) and shoulder balance were measured.


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_7 | Pages 4 - 4
1 Apr 2014
Frame M Ferguson K Jones B
Full Access

Introduction:

When having to remove broken or embedded metal implants using high speed burrs, the consequence is often a significant amount of metal debris which becomes embedded in the soft tissues. This may then act as a source for a foreign body inflammatory reaction or as a third body wear in the situation of joint arthroplasty. We describe a simple, cheap and effective method of reducing this debris using only a sterile water-based lubricating gel.

Materials & Methods:

Several experimental surgical models consisting of porcine muscle over a polyethylene tube with a large fragment titanium locking plate and screw secured to it were constructed. In 8 separate models a screw head locked within the plate was subjected to 90 seconds of high speed burring to create debris. On 4 models no water-based lubricating gel was utilized and on the remaining 4 the surrounding soft tissues were coated in the water-based lubricating gel (AQUAGEL, Halliburton – 42g £1.98). All models were then irrigated with NaCl 500mls using a 20mlsl syringe under manual pressure. Images were then captured after irrigation. The amount of debris was quantified by processing with ImageJ (a public domain, Java-based image processing program developed at the National Institutes of Health and is a computer automated program for counting particles.) The results were then statistically analysed using a student t test (IBM Corp. Released 2011. IBM SPSS Statistics for Windows, Version 20.0. Armonk, NY: IBM Corp.).


The Bone & Joint Journal
Vol. 96-B, Issue 3 | Pages 395 - 398
1 Mar 2014
Bailey O Torkington MS Anthony I Wells J Blyth M Jones B

The aim of this study was to determine if a change in antibiotic prophylaxis for routine hip and knee replacement was associated with an increased risk of acute renal impairment.

We identified 238 patients (128 knees and 110 hips) who had received a single prophylactic dose of 1.5 g cefuroxime before joint replacement. We compared them with prospectively collected data from 254 patients (117 knees and 137 hips) who received a single prophylactic dose of 2 g flucloxacillin and a height- and gender-determined dose of gentamicin. The primary outcome measure was any new renal impairment as graded by clinically validated criteria.

We identified four patients (1.69%) in the cefuroxime group who developed renal impairment. All four had mild impairment and all renal function was normal by the third post-operative day. The incidence of new-onset renal impairment was significantly higher in the flucloxacillin-and-gentamicin group at 9.45% (24 patients) (p < 0.001). Three of these patients remained with acute renal impairment after a week, although the serum creatinine levels in all subsequently returned to normal.

Cite this article: Bone Joint J 2014;96-B:395–8.


The Bone & Joint Journal
Vol. 96-B, Issue 3 | Pages 420 - 425
1 Mar 2014
Fahal AH Shaheen S Jones DHA

This article presents an overview of mycetoma and offers guidelines for orthopaedic surgeons who may be involved in the care of patients with this condition.

Cite this article: Bone Joint J 2014;96-B:420–5.


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_4 | Pages 23 - 23
1 Feb 2014
Jones L Roberts L Little P Wiles R Mullee M Cleland J Cooper C
Full Access

Purpose of the Study and Background

With a strong political agenda for change towards patient-centred healthcare, the notion of shared decision-making is reported to substantially improve patient experience, adherence to treatment and health outcomes. In clinical practice however, observational studies have shown shared decision-making is rarely implemented and patient preferences are seldom met.

The aim of this study was to measure the extent of shared decision-making in clinical encounters involving physiotherapists and patients with low back pain.

Methods and Results

Eighty outpatient encounters (from 12 clinicians) were observed, audio-recorded, transcribed verbatim and analysed using the OPTION instrument. This measures 12 decision-making items, rated on a scale 0–4, which are summated and scaled to give a percentage: The higher the score, the greater the shared decision-making competency.

The mean OPTION score was 24.0% (range 10.4%–43.8%). Providing patients with a list of treatment options was the only behaviour exhibited by every clinician, however in 73.8%, this was not demonstrated beyond a perfunctory level. Failure to offer the choice of doing nothing, or deferring the decision precluded clinicians from attaining a higher OPTION score.


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_4 | Pages 37 - 37
1 Feb 2014
Dunderdale C Jones F Billington J Khatri M
Full Access

Introduction

Spinal conditions commonly cause pain and disability. Various non-operative treatments including acupuncture are practiced for these conditions.

Aim

To evaluate the effectiveness of acupuncture in management of common spinal conditions.


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_1 | Pages 2 - 2
1 Jan 2014
Ahmad M Acharya M Clarke A Fernandes J Jones S
Full Access

Aim

To determine the rate of recurrence of coronal plane deformity in children treated with ‘guided growth’ using 8-plates, from the time of implant removal to skeletal maturity.

Methods

Over a consecutive 5 year period between April 2008 and April 2013 we analysed our results of guided growth treatment using 8-plates to correct coronal plane lower limb deformity. Patients with neuromuscular disorders such as cerebral palsy were excluded.

Deformity planning was performed using standardised techniques.

Our standard practice is to remove the 8-plate and screws once deformity is corrected both clinically and radiologically. Patients were followed up until either skeletal maturity or recurrence, which necessitated reapplication of the 8-plate.

We are aware of no study in which children treated with guided growth using 8-plates are followed up to skeletal maturity.


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_2 | Pages 1 - 1
1 Jan 2014
Wong F Mushtaq N Jones I Singh S Abbasian A
Full Access

Introduction:

Recent published studies have examined the normal dimensions of the syndesmosis on CT. However, previous anatomical studies have shown variations of the articulating facets within the tibialae fibularis and may contribute to the false appearance of increased spacing within the syndesmosis. In this study, we measured and compared anterior and posterior distances of the distal tibiofibular(DTF) syndesmosis on MRI and CT imaging.

Methods:

We identified adult patients who had had both a CT scan and an MRI scan of their ipsilateral ankle to investigate symptoms unrelated to the DTF syndesmosis. The anterior and the posterior DTF dimensions were measured on CT and MRI axial images, at the level of the distal tibial physeal scar. This was taken from anterior tubercle of tibia and from the most anterior aspect of the posterior tibial tubercle to the nearest point of medial aspect of the fibula. The geometrical shapes of the syndesmosis and the anterior tibial tubercle were also recorded.


The Bone & Joint Journal
Vol. 95-B, Issue 12 | Pages 1640 - 1644
1 Dec 2013
Agarwal S Azam A Morgan-Jones R

Bone loss in the proximal tibia and distal femur is frequently encountered in revision knee replacement surgery. The various options for dealing with this depend on the extent of any bone loss. We present our results with the use of cementless metaphyseal metal sleeves in 103 patients (104 knees) with a mean follow-up of 43 months (30 to 65). At final follow-up, sleeves in 102 knees had good osseointegration. Two tibial sleeves were revised for loosening, possibly due to infection.

The average pre-operative Oxford Knee Score was 23 (11 to 36) and this improved to 32 (15 to 46) post-operatively. These early results encourage us to continue with the technique and monitor the outcomes in the long term.

Cite this article: Bone Joint J 2013;95-B:1640–4.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_34 | Pages 476 - 476
1 Dec 2013
Banks S Watanabe T Kreuzer SW Leffers K Conditt M Jones J Park B Dunbar N Iorgulescu A
Full Access

INTRODUCTION

There is strong current interest to provide reliable treatments for one- and two-compartment arthritis in the cruciate-ligament intact knee. An alternative to total knee arthroplasty is to resurface only the diseased compartments with discrete compartmental components. Placing multiple small implants into the knee presents a greater surgical challenge than total knee arthroplasty, and it is not certain natural knee mechanics can be maintained. The goal of this study was to compare functional kinematics in cruciate-intact knees with either medial unicondylar (mUKA), mUKA plus patellofemoral (mUKA+PF), or bi-unicondylar (biUNI) arthroplasty using discrete compartmental implants with preparation and placement assisted by haptic robotic technology.

METHODS

Nineteen patients with 21 knee arthroplasties consented to participate in an I.R.B. approved study of knee kinematics with a cruciate-retaining multicompartmental knee arthroplasty system. All subjects presented with knee OA, intact cruciate ligaments, and coronal deformity ranging from 7° varus to 4° valgus. All subjects received multicompartmental knee arthroplasty using haptic robotic-assisted bone preparation an average of 13 months (6–29 months) before the study. Eleven subjects received mUKA, five subjects received mUKA+PF, and five subjects received biUKA. Subjects averaged 62 years of age and had an average body mass index of 31. Combined Knee Society Pain/Function scores averaged 102 ± 28 preoperatively and 169 ± 26 at the time of study. Knee range of motion averaged −3° to 120° preoperatively and −1° to 129° at the time of the study.

Knee motions were recorded using video-fluoroscopy while subjects performed step-up/down, kneeling and lunging activities. The three-dimensional position and orientation of the implant components were determined using model-image registration techniques (Fig. 1). The AP locations of the medial and lateral condyles were determined by computing a distance map between the femoral condyles and the tibial articular surfaces.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_34 | Pages 261 - 261
1 Dec 2013
Parekh J Jones H Chan N Noble P
Full Access

Introduction:

Angular mismatch of the modular junction between the head and the trunion has been recognized as a contributing factor to fretting and corrosion of hip prostheses. Excessive angular-mismatch can lead to relative motion at the taper interface, and tribo-corrosion of the head-neck junction secondary to disruption of the passive oxide layer. Although manufacturing standards have been adopted to define acceptable tolerances for taper angles of mating components, recent investigations of failed components have suggested that stricter tolerances or changes in taper design may be necessary to avoid clinical failures secondary to excessive taper wear and corrosion. In this study we examine the effect of angular-mismatch on relative motion between the taper and bore subjected to normal gait load using finite element methods.

Methods:

Computer simulations were executed using a verified finite element model (FEM), the results from which were determined to be consistent with literature. A stable, converging hexahedral mesh was defined for the trunnion (33648 elements) and a tetrahedral mesh for the femoral head (51182 elements). A friction-based sliding contact was defined at the taper-bore interface. A gait load of 1638N (2.34 × BW, BW = 700N) was applied at an angle of 30° to the trunnion axis (Figure 1) on an assembled FEM. A linear static solution was set up using Siemens NX-Nastran solver. Angular-mismatch was simulated by incrementing the conical half-angle of the bore to examine these cases: 0°, 0.005°, 0.010°, 0.015°, 0.030°, 0.050°, 0.075°, 0.100°, 0.200°and 0.300°.


Bone & Joint 360
Vol. 2, Issue 6 | Pages 2 - 8
1 Dec 2013
Jones R Wood D

This article provides an overview of the role of genomics in sarcomas and describes how new methods of analysis and comparative screening have provided the potential to progress understanding and treatment of sarcoma. This article reviews genomic techniques, the evolution of the use of genomics in cancer, the current state of genomic analysis, and also provides an overview of the medical, social and economic implications of recent genomic advances.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_34 | Pages 139 - 139
1 Dec 2013
Noble P Dwyer M Jones H Field RE McCarthy JC
Full Access

Introduction:

The sealing function of the acetabular labrum is central to the stability of the hip and the health of the joint. Disruption of the labrum has been shown to reduce intra-articular pressure and increase the rate of cartilage consolidation during static loading. Functional activities require movement of the hip through wide ranges of joint motion which disrupt joint congruency, and thus may alter the seal. This study was performed to test the hypothesis that the sealing function of the labrum varies with the position of the hip during functional activities.

Methods:

Six fresh cadaveric hip joint specimens were obtained from donors of average age 45.5 ± 16.1 years (range 25–63 years). Each specimen was dissected free of soft tissue, leaving the capsule and labrum intact, potted in mounting fixtures, and placed in a loading apparatus. Catheters were inserted into the central and peripheral compartments of each hip to allow infusion of fluid and monitoring of compartment pressures via miniature transducers (OMEGA Engineering, Inc). After application of a joint load of 0.50 BW, fluid was introduced into the central compartment at a constant rate until transport was indicated by a rise in pressure within the peripheral compartment. These measurements were performed with each hip placed in 10 functional positions ranging from −5 to 105 degrees of flexion, −5 to 13 degrees of abduction, and −25 to 35 degrees of external rotation simulating the sequential stages of gait, stooping, and pivoting. Motion analysis was performed via reflective marker arrays attached to the femur and pelvis to allow computer visualization of the position of the pelvis and femur using CT reconstructions. In each hip position, we measured the peak pressure (kPA) developed within the central compartment prior to fluid transfer to the peripheral compartment.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_34 | Pages 458 - 458
1 Dec 2013
Noble P Dwyer M Jones H Field RE McCarthy JC
Full Access

Objectives:

Experimental disruption of the labrum has been shown to compromise its sealing function and alter cartilage lubrication. However, it is not known whether pathological changes to the labrum secondary to femoro-acetabular impingement (FAI) have a similar impact on labral function. This study was performed to determine the effect of natural labral damage secondary to abnormal femoral morphology on the labral seal.

Methods:

Ten intact hip specimens were obtained from male donors (47.8 ± 1.5 yrs) for use in this study. CT reconstructions demonstrated that 6 specimens were of normal morphology, while 4 displayed morphology typical of cam-FAI. Specimens were dissected free of the overlying soft tissue, leaving the capsule and labrum intact. Each specimen was potted and placed in a loading apparatus (0.5 BW). Pressures developed within the central and peripheral compartments were monitored with miniature pressure transducers. The sealing capacity of the labrum was measured by introducing fluid into the central compartment at a constant rate until transport was detected from the central to the peripheral compartment. These measurements were performed in 10 functional positions simulating sequential stages of gait, stooping, and pivoting. During testing, the 3D motion of the femoral head in the acetabulum was measured with motion analysis combined with computer visualization. Peak pressures were compared between specimens with and without labral damage for each of the three activities (p < 0.05).


The Bone & Joint Journal
Vol. 95-B, Issue 11 | Pages 1441 - 1442
1 Nov 2013
Morgan-Jones R Haddad FS


The Bone & Joint Journal
Vol. 95-B, Issue 11_Supple_A | Pages 144 - 147
1 Nov 2013
Jones RE Russell RD Huo MH

Satisfactory primary wound healing following total joint replacement is essential. Wound healing problems can have devastating consequences for patients. Assessment of their healing capacity is useful in predicting complications. Local factors that influence wound healing include multiple previous incisions, extensive scarring, lymphoedema, and poor vascular perfusion. Systemic factors include diabetes mellitus, inflammatory arthropathy, renal or liver disease, immune compromise, corticosteroid therapy, smoking, and poor nutrition. Modifications in the surgical technique are necessary in selected cases to minimise potential wound complications. Prompt and systematic intervention is necessary to address any wound healing problems to reduce the risks of infection and other potential complications.

Cite this article: Bone Joint J 2013;95-B, Supple A:144–7.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_33 | Pages 6 - 6
1 Sep 2013
Robinson P Anthony I Kumar S Jones B Stark A Ingram R
Full Access

This study assesses the incidence of noise in ceramic on ceramic (COC) bearings compared to metal on polyethylene (MOP) bearings. Noise after MOP implants has rarely been studied and they never been linked to squeaking.

We have developed a noise characterising hip questionnaire and sent it along with the Oxford Hip Score (OHS) to 1000 patients; 509 respondents, 282 COC and 227 MOP; median age 63.7 (range 45–92), median follow up 2.9 years (range 6–156 months).

47 (17%) of the COC patients reported noise compared to 19 (8%) of the MOP patients (P=0.048). 9 COC and 4 MOP patients reported their hip noise as squeaking. We found the incidence of squeaking in the COC hips to be 3.2% compared to 1.8% in the MOP hips. Overall, 27% patients with noise reported avoiding recreational activities because of it and patient's with noisy hips scored on average 4 points less in the OHS (COC: P=0.04 and MOP: P =0.007).

This is the first study to report squeaking from MOP hip replacements. We therefore believe the squeaking hip phenomenon is not exclusive to hard bearings. Surprisingly, only a small proportion of patients described nose from their as a ‘squeak’. Noisy hip implants may have social implications, and patients should be aware of this. We have shown a relationship between noise and a lower OHS. However, longer follow-up and further study is needed to link noise to a poorly functioning implant.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_33 | Pages 10 - 10
1 Sep 2013
Jensen C Gupta S Sprowson A Chambers S Inman D Jones S Aradhyula N Reed M
Full Access

The cement used for hemiarthroplasties by the authors and many other surgeons in the UK is Palacos® (containing 0.5g Gentamicin). Similar cement, Copal® (containing 1g Gentamicin and 1g Clindamycin) has been used in revision arthroplasties. We aim to investigate the effect on SSI rates of doubling the gentamicin dose and adding a second antibiotic (clindamycin) to the bone cement in hip hemiarthroplasty.

We randomised 848 consecutive patients undergoing cemented hip hemiarthroplasty for fractured NOF into two groups: Group I, 464 patients, received standard cement (Palacos®) and Group II, 384 patients, received high dose, double antibiotic-impregnated cement (Copal®). We calculated the SSI rate for each group at 30 days post-surgery. The patients, reviewers and statistician were blinded as to treatment group.

The demographics and co-morbid conditions were statistically similar between the groups. The combined superficial and deep SSI rates were 5 % (20/394) and 1.7% (6/344) for groups I and II respectively (p=0.01). Group I had a deep infection rate 3.3 %(13/394) compared to 1.16% (4/344) in group II (p=0.082). Group I had a superficial infection rate 1.7 % (7/394) compared to 0.58% (2/344) in group II (p=0.1861). 33(4%) patients were lost to follow up, and 77 (9%) patients were deceased at the 30 day end point.

Using high dose double antibiotic-impregnated cement rather than standard low dose antibiotic-impregnated cement significantly reduced the SSI rate (1.7% vs 5%; p=0.01) after hip hemiarthroplasty for fractured neck of femur in this prospective randomised controlled trial.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_33 | Pages 7 - 7
1 Sep 2013
Lavery J Blyth M Jones B Anthony I
Full Access

To validate the Modified Forgotten Joint Score (MFJS) as a new patient-reported outcome measure (PROM) in hip and knee arthroplasty (THR/TKR) against the UK's gold standard Oxford Hip and Knee Scores (OHS/OKS).

The MFJS is a new assessment tool devised to provide a greater discriminatory power, particularly in well performing patients. It measures an appealing concept; the ability of a patient to forget about their artificial joint in everyday life.

Postal questionnaires were sent out to 400 THR and TKR patients who were 1–2 years post-op. The data collected from the 212 returned questionnaires was analysed in relation to construct and content validity. 77 patients took part in a test-retest repeatability assessment.

The MFJS proved to have an increased discriminatory power in high-performing patients in comparison to the OHS and OKS, highlighted by its more normal frequency of distribution and reduced ceiling effects. 30.8% of patients (n=131) achieved excellent OHS/OKS scores of 42–48 this compared to just 7.69% of patients who achieved a proportionately equivalent MFJS score of 87.5–100. The MFJS proved to have an increased test-retest repeatability based upon its intra-class correlation coefficient of 0.97 compared to the Oxford's 0.85.

The MFJS provides a more sensitive tool in the assessment of well performing hip and knee arthroplasties in comparison to the OHS/OKS. The MFJS tests the concept of awareness of a prosthetic joint, rather than pain and function and therefore should be used as adjunct to the OKS/OHS.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_30 | Pages 4 - 4
1 Aug 2013
Donaldson DQ Torkington M Jones B Blyth M
Full Access

Decreased oxygenation and delayed wound healing may negate the advantages of using a medial parapatellar incision in Total Knee Replacement. Tissue biochemical and blood flow data are not currently available in the literature.

20 patients were included in the study and randomised to midline or medial parapatellar skin incision groups, being supervised by one of 3 Consultant surgeons. Cutaneous blood flow was measured using a Speckle Contrast Blood Perfusion Imager at pre-operative and Days 1 & 3 post-operative intervals. Interstitial fluid measurements for lactate, pyruvate, lactate/pyruvate ratio and glucose were obtained from subcutaneous catheters with a dialysis membrane. Pre-operative samples were obtained from a catheter inserted into the prospective lateral wound edge. A catheter inserted after wound closure supplied dialysates at 0.5, 1, 2, 4, 6, 12 and 24-hour intervals. One catheter was corrupted on insertion; therefore the patients with biochemical data numbered 19.

Cutaneous blood flow improved over the 3 post-operative days in both types of incision and both sides, the medial retaining comparatively better flow. At Day 3, the parapatellar incision group displayed better flow on both sides of the wound. The concentration of lactate was highest in the parapatellar incision group of patients at all intervals. Pyruvate concentrations did not appear to differ across the incision types. Similarly, glucose concentrations did not appear to differ until after 4 hours, when higher concentrations were recorded in the midline group. Lactate/pyruvate ratio appeared to be notably greater in the parapatellar incision group. Plotting change in blood flow relative to change in lactate concentration demonstrated an increase in lactate as flow deteriorates.

The study findings suggest medial parapatellar incisions have increased anaerobic metabolites due to tissue hypoperfusion. Previous studies have demonstrated decreased oxygen tension in lateral based flaps and more recently the medial to lateral arterial anatomy has been demonstrated.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_31 | Pages 44 - 44
1 Aug 2013
Frame MC Jones B
Full Access

Many orthopaedic procedures require implants to be trialled before definitive implantation. Where this is required, the trials are provided in a set with the instrumentation. The most common scenario this is seen in during elective joint replacements. In Scotland (2007) the Scottish Executive (http://www.sehd.scot.nhs.uk/cmo/CMO(2006)13.pdf) recommended and implemented individually packed orthopaedic implants for all orthopaedic sets. The premise for this was to reduce the risk of CJD contamination and fatigue of implants due to constant reprocessing from corrosion. During many trauma procedures determining the correct length of plate or size of implant can be challenging. Trials of trauma implants is no longer common place. Many implants are stored in closed and sealed boxes, preventing the surgeon looking at the implant prior to opening and contaminating the device. As a result many implants are incorrectly opened and either need reprocessed or destroyed due to infection control policy, thus implicating a cost to the NHS. With even the simplest implants costing several hundreds of pounds, this cost is a very significant waste in resources that could be deployed else where. My project was to develop a method to produce in department accurate, cheap and disposable trials for implants often used in trauma, where the original manufacturer do not offer the option of a trial off the shelf. The process had to not involve contaminating or destroying the original implant in the production of a trial.

Several implants which are commonly used within Glasgow Royal Infirmary and do not have trials were identified. These implants were then CT scanned within their sealed and sterile packaging without contamination. Digital 3D surface renders of the models were created using free open source software (OsiriX, MeshLab, NetFabb). These models were then processed in to a suitable format for 3D printing using laser sintering via a cloud 3D printing bureau (Shapeways.com). The implants were produced in polyamide PA220 material or in 316L stainless steel. These materials could be serialized using gamma irradiation or ethylene oxide gas. The steel models were suitable for autoclaving in the local CSSU.

The implants produced were accurate facsimiles of the original implant with dimensions within 0.7mm. The implants were cost effective, an example being a rim mesh was reproduced in polyamide PA220 plastic for £3.50 and in 316L stainless steel for £15. The models were produced within 10 days of scanning. The stainless steel trials were durable and suitable for reprocessing and resterilisation.

The production of durable, low cost and functional implant trials all completed in department was successful. The cost of production of each implant is so low that it would be offset if just one incorrect implant was opened during a single procedure. With some of the implants tested, the trials would have paid for themselves 100 times. This is a simple and cost saving technique that would help reduce department funding and aid patient care.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_31 | Pages 51 - 51
1 Aug 2013
Robinson P Anthony I Stark A Jones B Ingram R
Full Access

The link between squeaking and ceramic on ceramic (CoC) bearings has been widely reported in orthopaedic literature and is described as a hard bearing phenomenon. We aim to look at the incidence of noise in CoC bearings compared to Metal on Polyethylene (MoP) bearing, which have yet to be linked to squeaking.

We developed a noise characterizing hip questionnaire and sent that along with the Oxford Hip Score (OHS) to 1000 patients; 3:2 ratio of CoC to MoP. 282 CoC patients and 227 MoP patients returned the questions: 509 patients in total. Our patient database provided details on femoral head size and the acetabular inclination angle, for each respondent

47 (17%) of the CoC hip patients reported noise compared to 19 (8%) of the MoP hip patients (P=0.054). 9 CoC patients and 4 MoP patients reported squeaking, while clicking was the most frequent answer in both groups. 27% patients with noise reported avoiding recreational activities because of it. Patient's with noisy hips scored on average, 5 points worse in the OHS (CoC: P = 0.04 and MoP: P = 0.007) and were on average 5 years younger (CoC: P<0.001 and MoP: P=0.007). No correlation was found between noisy hips and femoral head size or inclination angle.

The squeaking hip phenomenon is not exclusive to hard bearing THA. Noise from patient's hips may have social implications and this should be highlighted when consenting a patient for either of these hip procedures. In both implants, we showed there to be a correlation between noise production and a lower OHS. However, longer follow up studies are needed to link noise to a poorly functioning implant


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_31 | Pages 14 - 14
1 Aug 2013
Drury C Elias-Jones C Tait G
Full Access

Arthritis of the glenohumeral joint accompanied by an irreparable tear of the rotator cuff can cause severe pain, disability and loss of function, particularly in the elderly population. Anatomical shoulder arthroplasty requires a functioning rotator cuff, however, reverse shoulder arthroplasty is capable of addressing both rotator cuff disorders and glenohumeral deficiencies. The Aequalis Reversed Shoulder Prosthesis design is based on two bio-mechanical principles by Grammont; a medialized center of rotation located inside the glenoid bone surface and second, a 155 degree angle of inclination. Combined, they increase the deltoid lever arm by distalizing the humerus and make the prosthesis inherently stable.

24 consecutive primary reverse total shoulder arthroplasties were performed by a single surgeon for arthritis with rotator cuff compromise and 1 as a revision for a failed primary total shoulder replacement between December 2009 and October 2012. Patients were assessed postoperatively with the use of the DASH score, Oxford shoulder score, range of shoulder motion and plain radiography with Sirveaux score for scapular notching.

Mean age at the time of surgery was 72.5 years (range 59 to 86). Average follow up time was 19.4 months (range 4 to 38). Functional outcome scores from our series were comparable with patients from other follow up studies of similar prosthesis design. All patients showed improvement in range of shoulder movement postoperatively. Complications included one dislocation, one acromion fracture and one humeral shaft fracture. No cases of deep infection were recorded. Overall, the short-term clinical results were promising for this series of patients and indicate reverse shoulder arthroplasty as an appropriate treatment for this group of patients.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_30 | Pages 14 - 14
1 Aug 2013
Joseph J Anthony I Jones B Blyth M
Full Access

The purpose of this study was to evaluate the effect of body mass index (BMI) on patients undergoing primary total knee arthroplasty for osteoarthritis. Data was collected on 664 patients at 4 centres all of whom received a Depuy PFC Sigma prosthesis. Data collected included patient demographics, Oxford Knee Score (OKS), American Knee Society Score, SF-12, complications of surgery and the need for revision.

14% of patients had a BMI<25, 35% were overweight (BMI-25–30), 32% suffered from Grade 1 obesity (BMI-30–35) and 19% had grade 2 obesity (BMI>35). Obese patients were more likely to be female, have a higher ASA grade, present at a younger age and do sedentary work or no work at all. Pre-operative Oxford knee score was significantly worse in the BMI>35 group (p<0.001).

After surgery there was a significant improvement in functional outcome measures at 5 years post-operatively with all BMI groups improved by an average of 18 or 19 points in the OKS. However because those patients with high BMI have poorer pre-operative Oxford scores their post-operative scores were lower compared to patients with a normal BMI. Similar findings were noted with range of motion of the knee joint.

Overall complication rates were found to be significantly higher in obese patients and both revision surgery and deep infection rates increased stepwise with increasing BMI levels.

Deep Infection rates were as follows: BMI<25 0%, BMI-25–30 1.3%, BMI-30–35 1.4%, BMI-35–40 3.2% and BMI>40 6.1%.

Revision rates were as follows: BMI<25 0%, BMI-25–30 0.9%, BMI-30–35 0.9%, BMI-35–40 3.2% and BMI>40 6.1%.

Although obese patients with knee osteoarthritis do benefit from joint arthroplasty, they suffer from an increased rate of complications and need for revision surgery.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_30 | Pages 47 - 47
1 Aug 2013
Siddiqui M Bidaye A Baird E Jones B Stark A Abu-Rajab R Anthony I Ingram R
Full Access

We compared the postoperative wound discharge rates and 3 months clinical results of three types of wound closure and dressing – 2-octylcyanoacrylate with Opstie (G+O), 2-octylcyanoacrylate with Tegaderm (G+T), and Opsite without 2-octylcyanoacrylate (O) in patients having primary total hip arthroplasty.

We randomised 141 patients scheduled for primary total hip arthroplasty into 3 arms of this study- G+O, G+T, or O. The extent of wound discharge was recorded on a diagrammatic representation of the dressing in situ on paper and graded each day. Dressings were left in-situ provided the extent of wound discharge allowed for this. The patient was clinically reviewed at 3 months to assess their scar length, cosmesis, scar discomfort, and evidence of superficial or deep wound sepsis.

A greater number of patients dressings remained dry on day 1 postoperatively in the two groups with 2-octylcyanoacrylate compared to the no glue group p=0.001. G+T group had a significantly lower proportion of patients with increased leakage of wounds on 2nd postoperative day p=0.044. At 3 months review, there was no statistical difference in the Hollander score or scar discomfort.

In patients who have had primary total hip arthroplasty, usage of 2-octylcyanoacrylate for wound closure along with Tegaderm dressing reduces wound discharge. The same effect is not noted in glue with Opsite group. Whilst dressing changes required in the non-glue group compared from the two glue groups did not reach statistical significance, this may have clinical relevance for patients and nursing staff. No effect on postoperative length of stay, or wound complications was noted.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_28 | Pages 69 - 69
1 Aug 2013
Smith J Blyth M Jones B MacLean A Rowe P
Full Access

Total knee arthroplasty (TKA) has been established as a successful procedure for relieving pain and improving function in patients suffering from severe knee osteoarthritis for several decades now. It involves removing bone from both the medial and lateral compartments of the knee and sacrificing one or both of the cruciate ligaments. This in turn is likely to have an impact on the patients' functional outcome. In subjects where only one compartment of the knee joint is affected with osteoarthritis then unicondylar knee arthroplasty (UKA) has been proposed as an alternative procedure to TKA. This operation preserves the cruciate ligaments and removes bone only from the affected side of the joint. As a result there is the possibility of an improved functional outcome post surgery. UKA has been associated with faster recovery, good functional outcome in terms of range of motion and it is bone sparing compared to TKA. However, the biggest obstacle to UKA success is the high failure rates.

The aim of this study was to compare the functional outcome of computer navigated TKA (n=60) and UKA (n=42) patients 12 month post operation using flexible electrogoniometry. Flexible electrogoniometry was used to investigate knee joint kinematics during gait, slopes walking, stair negotiation, and when using standard and low chairs. Maximum, minimum and excursion knee joint angles were calculated for each task.

The biomechanical assessment showed statistically significant improvements in the knee kinematics in terms of maximum (p<0.0004) and excursion (p<0.026) knee joint angles in the UKA patient group compared to the navigated TKA group for each of the functional tasks. There was no statistically significant difference between the minimum knee joint angles during these functional tasks (p>0.05).

Therefore, UKA patients were showed to have a significantly better functional outcome in terms of the maximum knee joint angle during daily tasks. A limitation of this study is that it compares two cohorts rather than two randomised groups. It is expected that UKA patients will have a better functional outcome. Our results suggest that for patients with less severe knee osteoarthritis, UKA may offer a better functional outcome than the more common surgical option of TKA. The recent advancements in computer assisted and robotic assisted knee arthroplasty has the possibility to improve the accuracy of UKA and therefore led to the increase in confidence and in usage in a procedure which has the potential to give patients a superior functional outcome.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_31 | Pages 12 - 12
1 Aug 2013
Elias-Jones C MacLeod C
Full Access

In 2012 collagenase Clostridium histolyticum (Xiapex) was approved by the SMC for restricted use for the treatment of Dupuytren's contracture. Xiapex was approved on a case by case basis for patients with a palpable pretendinous cord, giving rise to MCPJ contracture of greater than 30 degrees. As of September 2012 we began to offer Xiapex injections to patients in Ayrshire who enquired about the injection, and met the SMC criteria.

To date injections have been performed on 3 patients, in a total of 7 digits. Patients were assessed prior to injection and manipulation, with the degree of contracture recorded and DASH scores noted. Each patient then underwent a standard injection of 0.58 mg of Xiapex. 48 hours post injection each patient underwent manipulation under local anaesthetic, with contractures remeasured, pain scored using a visual analogue scale and complications noted. Each patient was then reviewed at 4 weeks post injection where the residual degree of contracture was recorded and a further DASH score completed.

Mean contracture at the MCPJ prior to injection was 57° (range 34–80), and mean DASH score of 20.8 (range 16.7–24.2). Following manipulation mean residual contracture at the MCPJ measured 21° (range 18–28). The average pain score following was manipulation was rated at 1.1. Mild bruising and swelling were reported in all cases following injection, and manipulation resulted in 2 minor skin tears. At the 4 week review prolonged improvement of contracture was achieved with a mean residual contracture of 14° (range −2–40); with a significant improvement in DASH scores – mean 0.6 (range 0–1.8)

Despite small numbers, we have found Xiapex injections to be a successful and well tolerated treatment for moderate Dupuytren's disease. Further follow up is required to assess the longevity of the correction and ensure the cost effectiveness of Xiapex.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_30 | Pages 20 - 20
1 Aug 2013
Elias-Jones C Reilly J Kerr S Meek R Patil S Kelly M Campton L McInnes I Millar N
Full Access

Femoroacetabular impingement (FAI) is a significant cause of osteoarthritis in young active individuals but the pathophysiology remains unclear. Increasing mechanistic studies point toward an inflammatory component in OA. This study aimed to characterise inflammatory cell subtypes in FAI by exploring the phenotype and quantification of inflammatory cells in FAI versus OA samples.

Ten samples of labrum were obtained from patients with FAI (confirmed pathology) during open osteochondroplasty or hip arthroscopy. Control samples of labrum were collected from five patients with osteoarthritis undergoing total hip arthroplasty. Labral biopsies were evaluated immunohistochemically by quantifying the presence of macrophages (CD68 and CD202), T cells (CD3), mast cells (mast cell tryptase) and vascular endothelium (CD34).

Labral biopsies obtained from patients with FAI exhibited significantly greater macrophage, mast cell and vascular endothelium expression compared to control samples. The most significant difference was noted in macrophage expression (p<0.01). Further sub typing of macrophages in FAI using CD202 tissue marker revealed and M2 phenotype suggesting that these cells are involved in a regenerate versus a degenerate process. There was a modest but significant correlation between mast cells and CD34 expression (r=0.4, p<0.05) in FAI samples.

We provide evidence for an inflammatory cell infiltrate in femoroacetabular impingement. In particular, we demonstrate significant infiltration of mast cells and macrophages suggesting a role for innate immune pathways in the events that mediate hip impingement. Further mechanistic studies to evaluate the net contribution and hence therapeutic utility of these cellular lineages and their downstream processes may reveal novel therapeutic approaches to the management of early hip impingement.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_30 | Pages 16 - 16
1 Aug 2013
Kumar S O'Neill G Stark A Jones B McCartney P Wells J Ingram R
Full Access

The aim of this study was to characterise noise associated with ceramic-on-ceramic total hip arthroplasty (THA).

A questionnaire was constructed to assess noise associated with THA. 116 patients responded. All had ceramic-on-ceramic hybrid THA at Glasgow Royal Infirmary between 2005 and 2007 using a Trident prosthesis and Exeter stem. Oxford Hip Questionnaires (OHS) were also completed by the patients.

16.4% of respondents reported noise associated with their ceramic hip. The vast majority reported onset at least 1 year after implantation. The most common noise types were ‘clicking’ (47%) or ‘grinding’ (42%), while ‘squeaking’ was least frequently reported (11%). Noise was most commonly brought on by bending and during sit to stand movements.

No correlation was identified between the incidence of noise and any patient specific factor or demographic variable. The mean OHS at questionnaire follow-up was 39 and there was no significant difference in OHS when comparing noisy and silent hips (p=0.65). Only 1 patient limited social or recreational activities and overall patients felt the noise had minimal effect on their quality of life.

Acetabular component inclination angles were compared on post-operative x-rays. There was no significant difference (p=0.51) in inclination angles of the noisy (47.1°±6.3°, range 30–57°) and silent hips (47.8°±6.1°, range 35–68°). The groups were further analysed for deviation out with the desirable inclination range of 40–45°. Of the noisy hips, a total of 73% were out with this range compared to 63% in the silent hip group.

The incidence of noise within this ceramic-on-ceramic THA group did not appear to be related to patient specific factors, patient reported outcome (OHS) or acetabular inclination angles. Subjective appraisal of the noise revealed that ‘squeaking’ was not common but patients tended to report ‘clicking’ and ‘grinding’ more. The precipitation of noise with bending activities reinforces a possible mechanical cause.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_31 | Pages 39 - 39
1 Aug 2013
Lavery J Anthony I Blyth M Jones B
Full Access

To validate the Modified Forgotten Joint Score (MFJS) as a new patient-reported outcome measure (PROM) in hip and knee arthroplasty against the UK's gold standard Oxford Hip and Knee Scores (OHS/OKS).

The original Forgotten Joint Score was created by Behrend et al to assess post-op hip/knee arthroplasty patients. It is a new assessment tool devised to provide a greater discriminatory power, particularly in the well performing patients. It measures an appealing concept; the ability of a patient to forget about their artificial joint in everyday life. The original FJS was a 12-item questionnaire, which we have modified to 10-items to improve reliability and missing data.

Postal questionnaires were sent out to 400 total hip/knee replacement (THR/TKR) patients who were 1–2 years post-op, along with the OHS/OKS and a visual pain analog score. The data collected from the 212 returned questionnaires (53% return rate) was analysed in relation to construct and content validity. A sub-cohort of 77 patients took part in a test-retest repeatability study to assess reliability of the MFJS.

The MFJS proved to have an increased discriminatory power in high-performing patients in comparison to the OHS and OKS, highlighted by its more normal frequency of distribution and reduced ceiling effects in the MFJS. 30.8% of patients (n=131) scored 42–48 (equivalent to 87.5–100 in the MFJS) or more in the OKS compared to just 7.69% in the MFJS TKR patients. The MFJS proved to have an increased test-retest repeatability based upon its intra-class correlation coefficient of 0.968 compared to the Oxford's 0.845.

The MFJS provides a more sensitive tool in the assessment of well performing hip and knee arthroplasties in comparison to the OHS/OKS. The MFJS tests the concept of awareness of a prosthetic joint, rather than pain and function and therefore should be used as adjunct to the OKS/OHS.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_30 | Pages 17 - 17
1 Aug 2013
Boyle J Anthony I Jones B MacLean A Wheelwright E Blyth M
Full Access

A retrospective analysis was carried out to determine the influence of pre-existing spinal pathology on the outcome of Total Knee Replacement surgery. Data was collected from 345 patients who had undergone Total Knee Replacement, at four centres in the UK, between 2000 and 2007. Oxford Knee Scores (OKS), American Knee Society Scores (AKSS) and SF-12 questionnaires were recorded prospectively. Data was collected pre-operatively and then post-operatively at 3 months, 1 year and 2 years. Patients were divided into those with (n=40) and without a history of low back pain (n=305). In addition to determining the influence of low back pain on outcome after Total Knee Replacement we also examined the influence of concomitant hip and ankle pathology in the same cohort of patients.

OKS scores were significantly worse for patients with symptomatic low back pain at 3 (p=0.05), 12 (p=0.009) and 24 months (p=0.039) following surgery. SF-12 physical scores followed a comparable pattern with significance demonstrated at 3 (p=0.038), 12 (p=0.0002) and 24 months (p=0.016). AKSS followed a similar pattern, but significance was only reached at 1 year (p=0.013). The mental component of the SF-12 measure demonstrated a significant improvement in patients' mental health post-operatively for patients with no history of low back pain. In contrast patients with low back pain showed no improvement in mental health scores post-operatively.

In contrast to low back pain, hip and ankle pathology had no statistically significant detrimental effect on the outcome of Total Knee Replacement surgery.

This study demonstrates that low back pain significantly affects the functional outcome after Total Knee Replacement surgery and that patients with low back pain show no improvement in mental health post-operatively.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_31 | Pages 53 - 53
1 Aug 2013
Jensen C Gupta S Sprowson A Chambers S Inman D Jones S Aradhyula N Reed M
Full Access

Currently, the cement being used for hemiarthroplasties and total hip replacements by the authors and many other surgeons in the UK is Palacos® (containing 0.5g Gentamicin). Similar cement, Copal® (containing 1g Gentamicin and 1g Clindamycin) has been used in revision arthroplasties, and has shown to be better at inhibiting bacterial growth and biofilm formation. We aim to investigate the effect on SSI rates of doubling the gentamicin dose and adding a second antibiotic (clindamycin) to the bone cement in hip hemiarthroplasty.

We randomised 848 consecutive patients undergoing cemented hip hemiarthroplasty for fractured NOF at one NHS trust (two sites) into two groups: Group I, 464 patients, received standard cement (Palacos®) and Group II, 384 patients, received high dose, double antibiotic-impregnated cement (Copal®). We calculated the SSI rate for each group at 30 days post-surgery. The patients, reviewers and statistician were blinded as to treatment group.

The demographics and co-morbid conditions (known to increase risk of infection) were statistically similar between the groups. The combined superficial and deep SSI rates were 5 % (20/394) and 1.7% (6/344) for groups I and II respectively (p=0.01). Group I had a deep infection rate 3.3 %(13/394) compared to 1.16% (4/344) in group II (p=0.082). Group I had a superficial infection rate 1.7 % (7/394) compared to 0.58% (2/344) in group II (p=0.1861). 33(4%) patients were lost to follow up, and 77 (9%) patients were deceased at the 30 day end point. There was no statistical difference in the 30 day mortality, C. difficile infection, or the renal failure rates between the two groups.

Using high dose double antibiotic-impregnated cement rather than standard low dose antibiotic-impregnated cement significantly reduced the SSI rate (1.7% vs 5%; p=0.01) after hip hemiarthroplasty for fractured neck of femur in this prospective randomised controlled trial.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_30 | Pages 55 - 55
1 Aug 2013
Sciberras N Murphy E Jones B Blyth M
Full Access

Deep surgical infections are a serious complication of total knee arthroplasty (TKA). Various protocols exist for treating these infections, each with its own advocates. In this series we report the one to five year follow-up of infected TKA that were treated with a two-stage revision knee replacement at the Glasgow Royal Infirmary between December 2003 and March 2009.

48 patients were identified from the hospital database. 6 of these were excluded as they did not meet the stipulated infection criteria. Another patient was excluded as no notes were available thereby the infection status could not be determined. Another 8 patients were excluded as these only had a first stage.

33 patients (16 male) average age 67y (49–88) met the inclusion criteria. Mean BMI was of 31.62 (19–47) and 8 patients suffered from rheumatoid arthritis. At presentation, the median for the ESR, CRP and WCC were 70.5, 133 and 8.5 respectively. The infective organism was identified in 22 patients. Following the first stage, the patients were treated with antibiotics (initially intravenous followed by oral) for an average of 11.8 weeks (4–52 weeks). This procedure failed to eliminate the infection in 6 patients (18.18%) who had further re-admissions for infection of the affected prosthesis. The resultant success rate is of over 80% which is comparable to literature data (success rates of 41% to 96% quoted). For these patients, the average time to review was 25.13 months (12–67months). At review these patients had a mean extension of 2.17° (0–10°) and a mean flexion of 98.26 (70–120°). These patients were all satisfied with their outcome.

Our results show a high successful rate of elimination of infection when a two-stage revision is used for infected knee prosthesis with over 80% of patients free of infection.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_28 | Pages 91 - 91
1 Aug 2013
Motesharei A Rowe P Smith J Blyth M Jones B MacLean A
Full Access

Unicompartmental knee arthroplasty (UKA) has been gaining popularity in recent years due to its perceived benefits over total knee replacements, such as greater bone preservation, reduced operating-room time, better postoperative range of motion and improved gait. However there have been failures associated with UKA caused by misalignment of the implants.

To improve the implant alignment a robotic guidance system called the RIO Robotic Arm has been developed by MAKO Surgical Corp (Ft. Lauderdale, FL). This robotic system provides real-time tactile feedback to the surgeon during bone cutting, designed to give improved accuracy compared to traditional UKA using cutting jigs and other manual instrumentation.

The University of Strathclyde in association with Glasgow Royal Infirmary has undertaken the first independent Randomised Control Trial (RCT) of the MAKO system against the Oxford UKA – a conventional UKA used in the UK. The trial involves 139 patients across the two groups.

At present the outcomes have been evaluated for 30 patients. 14 have received the MAKO unicompartmental knee arthroplasty and 16 the Oxford UKA. Both groups were seen 1 year post-operatively. Kinematic data was collected while subjects completed level walking using a Vicon Nexus motion analysis system. Three-dimensional hip, knee and ankle angles were compared between the two arthroplasty groups.

Our initial findings indicate that hip and ankle angles show no significant statistical difference, however there is a significant difference (p < 0.05) in the knee angles during the stance phase of gait. Data shows higher angles achieved by the MAKO group over the Oxford.

It would appear from our early findings that the MAKO RIO procedure with Restoris implants gives at least comparable functional outcome with the conventional Oxford system and may prove once our full sample is available for analysis to produce better stance phase kinematics with a more active gait pattern than the conventional Oxford procedure.

Further work includes analysing the data obtained from the patients in a number of other activities. These include a full biomechanical analysis of ascending and descending a flight of stairs, sit to stand and a deep knee lunge. The high demand/high flexion tasks in particular may reveal if there's an advantage to using the MAKO procedure over the Oxford. If there is a direct correlation between alignment and patient function then this effect could be more significant in the more demanding patient tasks.


The Bone & Joint Journal
Vol. 95-B, Issue 6 | Pages 764 - 769
1 Jun 2013
Roche JJW Jones CDS Khan RJK Yates PJ

The piriformis muscle is an important landmark in the surgical anatomy of the hip, particularly the posterior approach for total hip replacement (THR). Standard orthopaedic teaching dictates that the tendon must be cut in to allow adequate access to the superior part of the acetabulum and the femoral medullary canal. However, in our experience a routine THR can be performed through a posterior approach without sacrificing this tendon.

We dissected the proximal femora of 15 cadavers in order to clarify the morphological anatomy of the piriformis tendon. We confirmed that the tendon attaches on the crest of the greater trochanter, in a position superior to the trochanteric fossa, away from the entry point for broaching the intramedullary canal during THR. The tendon attachment site encompassed the summit and medial aspect of the greater trochanter as well as a variable attachment to the fibrous capsule of the hip joint. In addition we dissected seven cadavers resecting all posterior attachments except the piriformis muscle and tendon in order to study their relations to the hip joint, as the joint was flexed. At flexion of 90° the piriformis muscle lay directly posterior to the hip joint.

The piriform fossa is a term used by orthopaedic surgeons to refer the trochanteric fossa and normally has no relation to the attachment site of the piriformis tendon. In hip flexion the piriformis lies directly behind the hip joint and might reasonably be considered to contribute to the stability of the joint.

We conclude that the anatomy of the piriformis muscle is often inaccurately described in the current surgical literature and terms are used and interchanged inappropriately.

Cite this article: Bone Joint J 2013;95-B:764–9.


The Bone & Joint Journal
Vol. 95-B, Issue 6 | Pages 738 - 746
1 Jun 2013
Palmer AJR Brown CP McNally EG Price AJ Tracey I Jezzard P Carr AJ Glyn-Jones S

Treatment for osteoarthritis (OA) has traditionally focused on joint replacement for end-stage disease. An increasing number of surgical and pharmaceutical strategies for disease prevention have now been proposed. However, these require the ability to identify OA at a stage when it is potentially reversible, and detect small changes in cartilage structure and function to enable treatment efficacy to be evaluated within an acceptable timeframe. This has not been possible using conventional imaging techniques but recent advances in musculoskeletal imaging have been significant. In this review we discuss the role of different imaging modalities in the diagnosis of the earliest changes of OA. The increasing number of MRI sequences that are able to non-invasively detect biochemical changes in cartilage that precede structural damage may offer a great advance in the diagnosis and treatment of this debilitating condition.

Cite this article: Bone Joint J 2013;95-B:738–46.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_24 | Pages 15 - 15
1 May 2013
Nunn TR Pratt E Dickens W Bell MJ Jones S Madan SS Fernandes JA
Full Access

Aim

The Pelvic Support Osteotomy (PSO) or Ilizarov Hip Reconstruction(IHR) is well described for the treatment of septic sequelae of infancy. The purpose of this study was to clinically, functionally and radiographically assess our short-term results of this procedure.

Method

25 patients (16 boys, 9 girls) who had undergone an IHR using the Ilizarov/TSF construct over a period of 10 years for a variety of pathologies were reviewed.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_22 | Pages 69 - 69
1 May 2013
Jones R
Full Access

Obtaining primary wound healing in Total Joint Arthroplasty (TJA) is essential to a good result. Wound healing problems can occur and the consequences can be devastating to the patient and to the surgeon. Determination of the host healing capacity can be useful in predicting complications. Cierney and Mader classified patients as Type A: no healing compromises and Type B: systemic or local healing compromises factors present. Local factors include traumatic arthritis with multiple previous incisions, extensive scarring, lymphedema, poor vascular perfusion, and excessive local adipose deposition. Systemic compromising factors include diabetes, rheumatic diseases, renal or liver disease, immune compromise, steroids, smoking, and poor nutrition. In high risk situations the surgeon should encourage positive patient choices such as smoking cessation and nutritional supplementation to elevate the total lymphocyte count and total albumin.

Careful planning of incisions, particularly in patients with scarring or multiple previous operations, is productive. Around the knee the vascular viability is better in the medial flap. Thus, use the most lateral previous incision, do minimal undermining, and handle tissue meticulously. We do all potentially complicated TKAs without tourniquet to enhance blood flow and tissue viability. The use of perioperative anticoagulation will increase wound problems.

If wound drainage or healing problems do occur immediate action is required. Deep sepsis can be ruled out with a joint aspiration and cell count, and negative culture and sensitivity. All hematomas should be evacuated and necrosis or dehiscence should be managed by debridement to obtain a live wound. Options available for coverage of complex wound problems include myocutaneous flaps, pedicled skin flaps, and skin grafts. Wet, occlusive dressings and wound VACs encourage epithelisation of chronic wounds.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_23 | Pages 5 - 5
1 May 2013
Fagg JA Kurian B Ahmad M Fernandes JA Jones S
Full Access

Purposes of the Study

To study the incidence of delayed consolidation of regenerate in children undergoing correction or lengthening of lower limb deformities using an external fixator.

Methods and Results

Between 2006 and 2011, 150 patients with lower limb deformities (excluding feet) were treated in our unit using external fixators. A retrospective review of our prospective database was carried out to identify patients with poor regenerate formation requiring bone grafting. Patients with acute fractures, pseudarthrosis of the tibia due to neurofibromatosis and those above the age of eighteen were excluded. An independent observer reviewed the medical records and radiographs.

Eleven patients with ages ranging from 2 years 5 months to 17 years 5 months (mean average 9 years 9 months) formed the basis of our study – 3 males and 8 females. Factors that were associated with this complication include age greater than twelve years (10 patients), lack of weight bearing (6 patients), previous fixator (5 patients) and smoking (5 patients). The regenerate was deficient in nine tibial segments and two femoral segments. Six of the deficient tibial regenerates were at a proximal site whilst three were distal. There was no significant difference in length gained between these sites (p < 0.5). The mean time to regenerate bone grafting was 7 months. Time to healing following bone grafting was 2.5 months.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_22 | Pages 110 - 110
1 May 2013
Jones R
Full Access

There are special circumstances in which revision total knee arthroplasty is not an option. The relative indications for the alternatives to revision TKA are: - Recurrent deep infection - Immunocompromised patient - Extensor mechanism loss - Extensive, non-reconstructable soft tissue loss - High functional demand, young age Remember the three A's as alternatives to revision TKA: arthrodesis, arthroplasty (resection), and amputation. Successful arthrodesis requires elimination of infection, coaptation of bone surfaces and rigid immobilisation. The proper position for arthrodesis is 15 degrees of knee flexion to allow foot clearance. If bone loss is greater than 3 cm fuse the knee in full extension. Avoid hyperextension. Achieve 5 degrees of valgus in correct rotation and use intramedullary instruments from TKA sets for best cuts. External fixation techniques as well as intramedullary internal fixation techniques will be described. Resection arthroplasty is indicated for salvage of an infected total knee when the patient is not a candidate for reimplantation. These patients usually have extensive soft and hard tissue loss. Procedure may be well tolerated and functional. Ancillary support with a long leg drop- lock KAFO increases stability and provides motion. Patients finding resection unacceptable are more likely to accept fusion or amputation; therefore resection may be a staging procedure. Amputation is indicated for failed multiple revisions, intractable or life threatening infection. Also should be indicated when there is a low chance of a successful arthrodesis. Ablate at the lowest level for infection eradication but good maintenance of function. Pedicle muscle flaps can be useful to fill dead spaces. Remember, elderly patients have limited ambulation potential because of high energy requirements of above knee amputation.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_25 | Pages 11 - 11
1 May 2013
Donaldson D Torkington M Anthony I Blyth M Jones B
Full Access

The longitudinal midline and medial-parapatellar incision are commonly used in Total Knee Arthroplasty (TKA). Medial-parapatellar incision n offers a smaller wound, avoids creation of thin skin flaps and easier exposure in obese patients. This incision creates a lateral skin flap which may be subject to poor blood supply and delayed wound healing.

We undertook a Randomised Controlled Trial (n=20) comparing midline and medial-parapatellar incisions. Cutaneous blood-flow was measured using a Doppler Imager. Interstitial fluid measurements for lactate, pyruvate, lactate/pyruvate ratio and glucose were obtained from subcutaneous microdialysis catheters. Wound cosmesis was graded and skin sensation tested.

Immediately post-op there was no significant difference in subcutaneous blood flow, but by day 3 patients with medial-parapatellar incisions showed greater bloodflow than midline incisions, particularly on the medial side (387 vs 278units p=0.148). At both day 1 and 3 post-op the lateral flap of the medial parapatellar incision showed decreased blood flow compared to the medial side, though these failed to reach significance. In contrast the midline incision showed no discernable difference in blood flow between the medial and lateral flaps. Concentrations of subcutaneous glucose increased from 4 hours post-op in the midline group, returning to baseline by 24hours. In contrast, the parapatellar group remained at base line throughout. Lactate concentrations increased over time in both groups peaking at 12hours post-op. No difference was noted between incision types with regard to wound cosmesis.

We conclude that the use of a medial-parapatellar incision results in only minimal biochemical changes, which are unlikely to alter wound healing. Medial-parapatellar incision is therefore a safe alternative to a midline incision and can be utilised in appropriate complex cases to aid surgical exposure.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_23 | Pages 24 - 24
1 May 2013
Nunn T Pratt E Dickens W Bell M Jones S Madan S Fernandes J
Full Access

The Pelvic Support Osteotomy (PSO) or Ilizarov Hip Reconstruction(IHR) is well described for the treatment of septic sequelae of infancy. The purpose of this study was to clinically, functionally and radiographically assess our short-term results of this procedure.

25 patients (16 boys, 9 girls) who had undergone a IHR using the Ilizarov/TSF construct over a period of 10 years for a variety of pathologies were reviewed. The mean age at surgery was 15 years 4 months. The pre-operative diagnoses were SCFE(10), hip sepsis (6), DDH (6) and Perthes (3). All had significant leg length discrepancies, 16 had a painful stiff hip, 6 had a painful mobile hip and 3 had a painless unstable hip. At surgery, a mean measured proximal valgus angle of 51° and a mean extension angle of 15° was achieved. Distal femoral lengthening averaged 4.2 cm and distal varus correction was a mean of 8°. The mean fixator time was 173 days.

At a mean of 2 years and 7 months follow-up the lower-extremity length discrepancy had improved from a mean of 5.6 cm apparent shortening to 2.3 cm. Trendelenberg sign was eliminated in 18/25 cases. Improvements in range of hip movements and gait parameters were observed. Stance time asymmetry, step length asymmetry, pelvic dip and trunk lurch improved significantly. One patient had conversion to a total hip replacement after 7 years, 4 patients required re-do PSO due to remodelling of the proximal osteotomies, two had heterotopic ossification and two had significant knee stiffness due to lack of compliance.

The early results of IHR are encouraging to equalise limb lengths, negate trendelenburg gait, provide a mobile hip with a reasonable axis and the possibility of conversion to THR in the future if needed. Complications need to be anticipated and the effects of remodelling and maintaining adequate knee range of motion must be emphasised.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_23 | Pages 8 - 8
1 May 2013
Sadr AH Josty I Drew P Williams P Wilson-Jones N
Full Access

Statement of purpose

To demonstrate how contemplating reconstructive options among members of Orthoplastic team can prevent accidental damage during initial wound debridement in foot and ankle injuries

Complex defects of the foot and ankle often require input from plastic and orthopaedic surgeons. There are different reconstructive options but one excellent regional option for small defects is the Extensor Digitorum Brevis muscle (EDB) flap. The anatomy of the flap and surgical technique and utility are described and demonstrated through a case series.

We present a series of 4 consecutive cases of the use of the pedicled EDB flap for soft tissue coverage of difficult defects around the foot and ankle. This regional pedicled flap can be proximally based to cover defects around the ankle or distally based for distal foot coverage. When possible, it facilitates a reconstruction with minimal donor site morbidity, shorter operating times, and fewer complications than alternative options

The flap would usually be performed by the plastic surgical member of the orthoplastic team, but an understanding of it by foot and ankle and reconstructive orthopaedic surgeons is relevant as it's vascular supply via the lateral tarsal artery can be easily damaged, preventing its use in the management of wound complications or trauma.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_16 | Pages 62 - 62
1 Apr 2013
Moazen M Mak JH Etchels L Jones AC Jin Z Wilcox RK Tsiridis E
Full Access

There are a number of periprosthetic femoral fracture (PFF) fixation failures. In several cases the effect of fracture configuration on the performance of the chosen fixation method has been underestimated. As a result, fracture movement within the window that seems to promote callus formation has not been achieved and fixations ultimately failed.

This study tested the hypothesis that: PFF configuration and the choice of plate fixation method can be detrimental to healing.

A series of computational models were developed, corroborated against measurements from a series of instrumented laboratory models and in vivo case studies. The models were used to investigate the fixation of different fracture configurations and plate fixation parameters. Surface strain and fracture movement were compared between the constructs.

A strong correlation between the computational and experimental models was found. Computational models showed that unstable fracture configurations increase the stress on the plate fixation. It was found that bridging length plays a pivotal role in the fracture movement. Rigid fixations, where there is clinical evidence of failure, showed low fracture movement in the models (<0.05mm); this could be increased with different screw and plate configurations to promote healing.

In summary our results highlighted the role of fracture configuration in PFF fixations and showed that rigid fixations that suppress fracture movement could be detrimental to healing.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_17 | Pages 27 - 27
1 Apr 2013
Owen SJ Roberts S Eisenstein S Jones P Sharp CA
Full Access

Background

Intervertebral disc cells exist in a challenging physiological environment. Disc degeneration occurs early in life implying that disc cells may no longer be able to maintain a functional tissue. We hypothesise that disc cells have a stress response different from most other cells because of the disc environment. We have compared the stress response of freshly isolated and cultured bovine nucleus pulposus (NP) cells with bovine dermal fibroblasts, representative of cells from a vascularised tissue.

Methods

Freshly isolated and passaged bovine NP cells and dermal fibroblasts were cultured for 3 days then subjected to either thermal stress at 45°C for 1h followed by recovery times of 6, 24 and 48h or nutrient stress involving culture without serum for 6, 24 and 48 h. At each time point, cell number and viability were assessed and heat shock protein 70 (Hsp70) measured in cell lysates by an enzyme-linked immunosorbent assay.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_16 | Pages 22 - 22
1 Apr 2013
Tan H Cuthbert RJ Jones E Churchman S McGonagle D Giannoudis PV
Full Access

We hypothesise that the Masquelet induced membrane used for the reconstruction of large bone defects were likely to involve mesenchymal stem cells (MSCs), given the excellent resultant skeletal repair. This study represents the first characterisation in humans of the induced membrane formed as a result of the Masquelet technique.

Methods

Induced membranes and matching periosteum were harvested from 7 patients. Cytokines (BMP2, VEGF, SDF1) and cell lineage markers (CD31, CD271, CD146) were studied by immunohistochemisty. Flow cytometry was used to measure the cellularity and cellular composition. MSCs were enumerated using a colony forming unit fibroblast assay. In expanded cultures, a 96-gene array card was used to assess their transcriptional profile. Alkaline phophatase, alizarin red and calcium assays were employed to measure their in vitro osteogenic potential

Results

Membrane was more cellular(p=0.028), had more MSC phenotype(p=0.043) compared to matched periosteum. The molecular profiles were similar, except for 2-fold abundance of SDF-1 in membrane (p=0.043)compared to periosteum. Membrane and periosteum had a similar proportion of endothelial cells and CFU-F colonies; expanded MSCs from both sources were highly osteogenic.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_21 | Pages 7 - 7
1 Apr 2013
Jones H Hickey B Ghaffar A Perera A
Full Access

Background

Despite the suggestion by Virchow in 1856 that thrombosis was the result of venous stasis, endothelial dysfunction and hypercoagulability there are some fundamental questions which remain to be answered. The published studies fail to provide specific details such as cast type and anatomical location of the thrombosis, but instead focus on the incidence of VTE and which chemical thromboprophylaxis is most effective. Previous studies of VTE in trauma patients have involved small numbers of patients and have not look at the risk medium to long term risk. Most importantly they have not looked at the site of the VTE. This makes interpretation of the link between cast and VTE even more complex.

Methodology

We analysed 1479 consecutive trauma cast applications and the incidence of symptomatic VTE in the six months following the injury. The diagonosis, cast type and site of the VTE was recorded.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_19 | Pages 1 - 1
1 Apr 2013
Kotwal R Moideen AN Jones S
Full Access

Introduction

The reverse obliquity fractures of the proximal femur are anatomically and mechanically different from most intertrochanteric fractures. These fractures are complex and very difficult to treat. To evaluate the results of the treatment of reverse obliquity intertrochanteric fractures with cephalomedullary nails.

Materials and Methods

Between 2005 and 2009, 1179 extracapsular fractures of the proximal femur were treated at our institution. Retrospective review of these x-rays identified 59 patients with reverse obliquity fracture pattern. We analysed our results of cephalomedullary nailing of these complex fractures and evaluated factors responsible for failure of fixation.


The Bone & Joint Journal
Vol. 95-B, Issue 4 | Pages 530 - 535
1 Apr 2013
Roche CP Marczuk Y Wright TW Flurin P Grey S Jones R Routman HD Gilot G Zuckerman JD

This study provides recommendations on the position of the implant in reverse shoulder replacement in order to minimise scapular notching and osteophyte formation. Radiographs from 151 patients who underwent primary reverse shoulder replacement with a single prosthesis were analysed at a mean follow-up of 28.3 months (24 to 44) for notching, osteophytes, the position of the glenoid baseplate, the overhang of the glenosphere, and the prosthesis scapular neck angle (PSNA).

A total of 20 patients (13.2%) had a notch (16 Grade 1 and four Grade 2) and 47 (31.1%) had an osteophyte. In patients without either notching or an osteophyte the baseplate was found to be positioned lower on the glenoid, with greater overhang of the glenosphere and a lower PSNA than those with notching and an osteophyte. Female patients had a higher rate of notching than males (13.3% vs 13.0%) but a lower rate of osteophyte formation (22.9% vs 50.0%), even though the baseplate was positioned significantly lower on the glenoid in females (p = 0.009) and each had a similar mean overhang of the glenosphere.

Based on these findings we make recommendations on the placement of the implant in both male and female patients to avoid notching and osteophyte formation.

Cite this article: Bone Joint J 2013;95-B:530–5.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_16 | Pages 25 - 25
1 Apr 2013
KOUROUPIS D JONES E BABOOLAL T GIANNOUDIS PV
Full Access

Introduction

The concept of “bone graft expanders” has been popularised to increase the volume and biological activity of the implanted Material.

HYPOTHESIS

Orthoss® granules support exogenously seeded MSCs and attract neighbouring host MSCs.