Abstract
Aim
To determine the rate of recurrence of coronal plane deformity in children treated with ‘guided growth’ using 8-plates, from the time of implant removal to skeletal maturity.
Methods
Over a consecutive 5 year period between April 2008 and April 2013 we analysed our results of guided growth treatment using 8-plates to correct coronal plane lower limb deformity. Patients with neuromuscular disorders such as cerebral palsy were excluded.
Deformity planning was performed using standardised techniques.
Our standard practice is to remove the 8-plate and screws once deformity is corrected both clinically and radiologically. Patients were followed up until either skeletal maturity or recurrence, which necessitated reapplication of the 8-plate.
We are aware of no study in which children treated with guided growth using 8-plates are followed up to skeletal maturity.
Results
267 patients were treated with 8-plates in our unit over this 5 year period. Of the patients in whom deformity was corrected and had subsequent plates removed, we identified 41 patients who have either reached skeletal maturity or had recurrence of deformity. Six patients required reapplication of the 8-plates implant. These were young and had skeletal dysplasia. Deformity parameters were analysed both clinically and radiologically in patients who have reached skeletal maturity and showed no recurrence, which necessitated further intervention.
Conclusion
A higher proportion of younger patients, especially a sub-group with skeletal dysplasia had recurrence of deformity necessitating reapplication of the 8-plate device. In this group we recommend removal of only the metaphyseal screw once deformity is corrected. This would allow ease of reapplication if recurrence were to reoccur.