To evaluate the clinical success and hip pain and function of patients with infected hip replacement treated by two-stage exchange using a temporary implant with high dose vancomycin added to the antibiotic cement at the first stage revision. Thirty-three hips in 32 patients (median 67 yrs) underwent first stage revision using the PROSTALAC™ system (n=27) or a self-made system using an Elite long stem (n=6). Infection was diagnosed after 19 primary, 11 revision and 3 hemiarthroplasty hip replacements. Patients were reviewed regularly clinically and by questionnaire. The median follow-up was 3 years.Introduction
Method
This study aimed to compare the early clinical results and stem subsidence between three consecutive series of revision hip replacement cases with femoral impaction bone grafting to evaluate the effects of developments in technique. In the original series 1 (n=23), bone graft was irradiated at 25kG. I n series 2 (n=12) non-irradiated double washed graft and long stems were used as required. In series 3 (n=21) modular tamps were used. Sensitive radiographic analysis techniques, EBRA and RSA, were used to measure stem subsidence. Major stem re-revision was required in five hips in series one, one hip in series two and no hips in series three. Two periprosthetic fractures occurred in series one. There was a statistically significant reduction in stem subsidence at the cement-bone interface at 12 months between series one and series two and three (p<0.05). In series three there was negligible stem subsidence at the cement-bone interface. Technique developments in femoral impaction grafting, including the use of modular tamps designed to simply the procedure, yields excellent early clinical and radiographic results. Using RSA, we have shown that the fixation of the stems in bone is comparable to that achieved in primary hip replacement.
While computed tomography (CT) provides an accurate measure of osteolysis volume, it would be advantageous in general clinical practice if plain radiographs could be used to monitor osteolysis. This study determined the ability of plain radiographs to detect the presence of and determine the progression in size of osteolytic lesions around cementless acetabular components. Nineteen acetabular components were diagnosed with osteolysis using a high-resolution multi-slice CT scanner with metal artefact suppression. Mean duration since arthroplasty was 14 years (range 10–15 years) at initial CT. Repeat CT scans were undertaken over a five year period to determine osteolysis progression. On anteroposterior pelvis (AP) radiographs and oblique radiographs of the acetabulum seen on the rolled lateral hip view, which were taken at the same time as the CT scans, area of osteolysis was measured manually correcting for magnification. Osteolysis was detected on the AP radiographs in 8 of 19 hips (42%), on the oblique radiographs in 6 of 19 hips (32%) and on the combined AP and oblique radiographs in 8 of 19 hips (42%). Throughout the study period, osteolysis was detected on 31 of 76 AP radiographs (41%) and 22 of 75 oblique radiographs (29%). Osteolysis was more likely to be detected on plain radiographs if the lesion volume was greater than 10cm3 in size (p=0.005). On CT, osteolysis progressed by more than 1cm3/yr in 10 of 19 hips (55%). In these ten hips, osteolysis progression was detected on AP radiographs in six hips and on oblique radiographs in three hips. No correlation was found between osteolysis progression measured by CT and that measured on AP (r2=0.16, p=0.37) or oblique (r2=0.37, p=0.15) or AP and oblique radiographs (r2=0.34, p=0.17). Plain radiographs are poor in monitoring progression in size of periacetabular osteolytic lesions. Plain radiographs may detect lesions more than 10cm3 in size, but are unreliable.
Computed tomography (CT) provides a sensitive and accurate measure of periacetabular osteolytic lesion volume, however, there may remain a role for plain radiographs in monitoring osteolysis. This study aimed to compare CT and plain radiographs for determining the progression in size of osteolytic lesions around cementless acetabular components. A high-resolution multi-slice CT scanner with metal artefact suppression was used to determine the volume and progression of osteolysis around 19 cementless Harris Galante-1 and PCA acetabular components. The mean duration since arthroplasty was 14 years (range 10–15 years) at initial CT. Repeat scans of the hip were undertaken over a five year period to determine the progression in size of osteolytic lesions over time. A second blinded observer manually measured the area of osteolytic lesions off anteroposterior pelvis radiographs and oblique radiographs of the acetabulum that were taken at the same time as the CT scan. All 19 hips had CT detected osteolysis. Osteolysis was detected on one or both of the anteroposterior pelvis or oblique radiographs from at least one time point in eight of 19 hips (42%). Osteolysis was detected on 31 of 76 anteroposterior pelvis radiographs (41%) and on 22 of 75 oblique radiographs (29%) (p=0.140). Osteolysis was more likely to be detected on plain radiographs if the lesion volume was greater than 10cm3 in size compared to those 5–10cm3 and less than 5cm3 in size (p=0.009). In 10 of 19 hips (55%), CT determined that osteolytic lesions progressed in size by more than 1cm3/yr. The mean volume of osteolysis progression was 3.2cm3/yr (range 1.1–7.5cm3/yr). Progression in size of osteolytic lesions was significantly associated with hips with larger osteolytic lesions at the initial CT (p=0.0004). Radiographic measurements detected progression of osteolytic lesions in 5 of the 10 hips (50%) that progressed. No correlation was found between progression in size of osteolytic lesions as measured by CT and progression in size of osteolytic lesions as measured off the anteroposterior pelvis (r2 = 0.16, p=0.37), oblique (r2=0.37, p=0.15) and combined anteroposterior pelvis and oblique radiographs (r2=0.34, p=0.17). Periacetabular osteolytic lesions are more likely to be detected on plain radiographs if they are more than 10cm3 in size. Plain radiographs may therefore provide some monitoring value as lesions more than 10cm3 are more likely to be progressive. However, plain radiographs should not be relied upon to monitor the progression of these lesions.
Differentially loaded radiostereometric analysis (DLRSA) uses RSA whilst simultaneously applying load to the bones under investigation. This technique allows measurement of interfragmentary translations and rotations under measured weight bearing and joint movement. We have recently introduced this technique to monitor tibial plateau fracture healing. This paper presents our preliminary results. Twelve patients with a 41 B2, B3, C2, or C3 fracture were followed for a minimum of three months. RSA beads were inserted in the largest osteochondral fragment and the adjacent metaphysis. Knee flexion was restricted to 60° for 6 weeks. After partial weight bearing (20kg) between 2 and 6 weeks, patients progressed to full weight bearing. Follow up included clinical and radiological examinations and patient reported outcome scores (Lysholm, KOOS). DLRSA examinations included RSA radiographs in 60° flexion and under measured weight bearing. Significant interfragmentary displacement was defined as translations greater than 0.5mm and/or rotations greater than 1.5°. There was no loss to follow-up. Longitudinal RSA follow-up: Follow-up RSA radiographs were compared to postoperative examinations. Osteochondral fragment depression was less than 0.5mm in seven patients and between 2 and 4mm in the remaining five patients. Significant interfragmentary displacement after three months was recorded in three patients. DLRSA flexion results: Under 60° of flexion, translations over 0.5mm were recorded in five patients (one postoperatively; one at 2 weeks; two at 6 weeks; and one postoperatively, at 2 weeks and at 3 months). Rotations over 1.5° were recorded in six patients (one postoperatively; two at 2 weeks; one at 6 weeks; one at 2 weeks, 3 months and 4.5 months; and one postoperatively, at 2 weeks, 3 months and 6 months). DLRSA weight bearing results: Under partial weight bearing at two weeks, two patients recorded significant translations, one involving a significant rotation. Under weight bearing as tolerated, three patients recorded significant translations (one at 6 weeks; and two at 18 weeks) and four patients recorded significant rotations (one at 6 weeks; one at 18 weeks; and two at 12 and 18 weeks). Patient Reported Outcomes: Both the Lysholm and KOOS scores improved between 6 weeks and 3 months. DLRSA provides new insight and perspective in tibial plateau fractures. Some fractures take more than three months to heal. Our current rehabilitation protocol was safe in most patients, however significant interfragmentary displacement was encountered in 17% at the 2 week followup, raising questions about the quality of the initial stability.
Differentially loaded radiostereometric analysis (DLRSA) uses RSA whilst simultaneously applying load to the bones under investigation. This technique allows measurement of interfragmentary translations and rotations under measured amounts of weight bearing. The aim of this paper was to measure the mechanical stiffness of distal femoral fractures during healing. Six patients with a 33A2, 33A3, 33B2 and 33C2 fracture were treated with open reduction, internal fixation using a long bridging plate. All patients had a DLRSA examination at 6, 12, 18 and 26 weeks postoperatively. Each DLRSA examination consisted of RSA radiographs taken without load (pre-load), under different increments of load, and finally, without load (post-load). The direction and magnitude of the interfragmentary displacements in six degrees of freedom were recorded at each examination. DLRSA examinations were able to monitor the inter-fragmentary displacements of the distal femoral fragment relative to the femoral shaft. The interfragmentary displacement recorded, progressively increased as more load was applied in all patients, at all follow-up time points. The two dimensional (2D) translations under maximum tolerated load, progressively decreased over time in three patients. The 2D translations recorded under 60 kg of load at 26 weeks for these patients was 0.18, 0.21 and 0.27mm. The 2D translations of two patients did not decrease progressively between 6 and 18 weeks but did decrease at 26 weeks to 0.47 and 0.75mm. One patient recorded 2D translations of 4.11, 3.48 and 4.53mm under 30kg at 12, 18 and 26 weeks respectively. In the majority of examinations, post-load radiographs enabled the interfragmentary displacements under load to be identified as elastic in nature. The DLRSA stiffness data confirmed that at 26 weeks three patients had united; two were delayed but improving; and one was a clear non-union without progression. DLRSA examinations may be used as a clinical research tool. to monitor in vivo the stiffness of healing femoral fractures fixed with “relative stability”.
Irradiating allograft bone may compromise the mechanical stability of the prosthesis-bone construct, potentially having adverse effects on the outcome of femoral impaction grafting at revision hip replacement. This in vitro study aimed to determine the effect of irradiation of allograft bone used in femoral impaction grafting on initial prosthesis stability. Morsellised ovine femoral head bone was irradiated at 0 kGy (control), 15 kGy and 60 kGy. For each group, six ovine femurs were implanted with a cemented polished double taper stem following femoral impaction bone grafting. Dynamic hip joint loading was applied to the femoral head using a servo-hydraulic materials testing machine. The primary outcome was stem micromotion. Tri-axial micromotion of the stem relative to the bone at two sites was measured using linear variable differential transformers and non-contact laser motion transducers. Statistical analysis was performed using SPSS. Compared to the control and 15 kGy groups, specimens in the 60 kGy group demonstrated statistically significant greater micromotion in the axial, antero-posterior and medio-lateral axes. A multi-factorial post-hoc power analysis based on the overall effect of group size indicated a power of 0.7. There was no difference in micromotion between the control and 15 kGy groups. The average micromotion in the axial axes was 63μm in the control and 59μm in the 15 kGy group. The results of this study suggest that a maximum irradiation dose of 15 kGy may not affect initial prosthesis stability following femoral impaction grafting in this model and provide the basis for us to now proceed to in-vivo studies examining the effect of irradiated bone on implant stability over time.
Periprosthetic osteolysis is a serious medium to long-term complication of total hip arthroplasty. Interobserver reliability of detecting osteolysis around cementless ace-tabular components is reported to be poor using plain radiographs. Quantitative computed tomography (CT) provides sensitive and accurate measures of osteolytic lesion volume, however, there may remain a role for plain radiographs in monitoring progression of osteolysis. The aim of this study was to use quantitative CT to monitor the progression of osteolytic lesions around cementless acetabular components and to compare plain radiographs and CT in determining the progression of osteolysis. A high-resolution multi-slice quantitative CT scanner with metal artefact suppression was used to determine the volume of osteolysis around 18 cementless acetabular components. The mean time since arthroplasty was 14 years (range 10–15 years) at the initial CT. Repeat scans of the hip were undertaken over a five-year period to determine progression of osteolysis with time. A second blinded observer examined anteroposterior and lateral plain radiographs taken at the same time as the CT scans and measured the location and area of osteolytic lesions. CT measurements determined that in ten of 18 hips (56%), osteolytic lesions progressed by more than 1cm3/yr. Progression in size of osteolytic lesions was significantly associated with hips with larger osteolytic lesions at the initial CT (p=0.0005). The mean volume of osteolysis progression was 4.9cm3/year (range 2.8–7.5cm3/yr) for cases with osteolysis volumes greater than 10cm3 at the initial CT, and 0.7cm3/yr (range 0–2.3cm3/yr) for cases with osteolysis volumes smaller than or equal to 10cm3 at the initial CT (p=0.002). Importantly, the rate of osteolysis progression between CT scans varied greatly in some hips. In contrast, using plain radiograph assessment, progression in the area of osteolytic lesions was only detected in 10% of hips. In conclusion, quantitative CT provides new insights into the natural history of periacetabular osteolysis. Total osteolysis volume greater than 10cm3 is associated with a high risk of progression and progress, on average, at a greater rate than those less than 10cm3. Plain radiographs, including a lateral view, are an unreliable clinical diagnostic tool to predict substantial progression of periacetabular osteolytic lesions.
In relation to the conduct of this study, one or more of the authors is in receipt of a research grant from a non-commercial source.
In relation to the conduct of this study, one or more of the authors is in receipt of a research grant from a non-commercial source.
In relation to the conduct of this study, one or more of the authors is in receipt of a research grant from a non-commercial source.
The purpose of health outcomes monitoring is to assess the benefits and risks of health care processes, to enable benchmarking and to allow comparative studies of new technologies and variations in clinical practice. This paper critically reviews the discipline of health outcomes monitoring in joint replacement surgery. We reviewed over 250 papers published over the last 20 years in the major English speaking journals were reviewed. We conclude that there are considerable shortcomings of clinical studies which make it difficult to determine the results of different joint replacement designs. The shortcomings include inadequate study design and the lack of comparative data. Despite repeated calls for standardisation of outcome measures, this has yet to be achieved. Considerable resources are often invested in outcomes monitoring programs.It is therefore important that instruments are selected based on them meeting strict psychometric criteria, that adequate follow-up is achieved and that appropriate data analysis techniques are utilised, otherwise interpretation of results is difficult. We have found that patients’ reporting of symptoms and outcomes after hip arthroplasty were found to be consistent with those reported by their reviewing doctor. We therefore suggest that for uncomplicated joint arthroplasty cases, the marginal costs of their regular review in outpatients probably outweighs the marginal benefits and important resources and doctors time would be made available for other patient care activity if these patients were reviewed by patient self-administered questionnaires. Our studies have shown that SF-36 health survey and the WOMAC instruments are useful when administered by mailed survey, however, the cost-benefits of using these outcomes instruments is an important consideration. The lack of comparable outcomes data should encourage greater orthopaedic participation in multi-centre outcomes studies including randomised trials.
Reported rates of dislocation after primary and revision total hip replacement (THR) vary widely, whereas subluxation after THR is not commonly reported. Importantly, it is now recognised that reported dislocation rates are likely to be an underestimate of the true dislocation rate. The primary aim of this study was to develop and validate a Patient Hip Instability Questionnaire and subsequently to use this questionnaire to determine the incidence of dislocation, subluxation and symptoms due to hip instability following primary and revision THR. In addition the associated costs, morbidity, disability and effects on health-related quality of life were examined. A retrospective review of dislocation rates from 1996 to 1998 identified problems in determining the true dislocation rate from standard hospital and database records. Therefore, a patient-completed Hip Instability Questionnaire was developed and validated to monitor dislocation and subluxation rates. This was then mailed to patients three and 12 months following primary or revision THR. All dislocations were then confirmed by telephone interview and radiographs. Telephone interviews and patient completion of the SF-36 questionnaire were used to assess morbidity, disability and quality of life. Costs of treating patients with hip dislocation were also determined. The response rate to the mailed questionnaire was greater than 95%. The questionnaire was shown to be a valid measure of the true rate of dislocation following THR and confirmed the inaccuracies in previous methods of determining dislocation rate based on hospital and database records. Using this questionnaire, the rate of subluxation was higher than previously reported and the significant morbidity and health care costs associated with with this complication were identified. The use of this questionnaire will allow better assessment of morbidity and costs due to complications following THR.
Loosening was classified as possible if there was between 50 and 99 percent c-b radiolucency, probable when there was complete radiolucency, or definite when vertical subsidence was more than 5mm. The presence and type of radiological features analysed according to surgeon and whether a centraliser was utilised.