Studies and meta-analyses worldwide show an increased use of one-stage revisions for treating periprosthetic hip infections, often yielding comparable or better outcomes than two-stage revisions. However, it remains unclear if these successful results can be consistently achieved nationwide besides large centers. This observational cohort study used data from the German Arthroplasty Registry (EPRD) to compare the mortality and re-revision rates between one-stage (n=8183) and two-stage (n=657) first-time revision total hip arthroplasty (RTHA). Kaplan-Meier estimates were applied to evaluate the re-revision rate and cumulative mortality for RTHA. There was a significant difference in mortality between one-stage and two-stage RTHA (p=0.02). One-year post-surgery, the mortality rate was 9.4% for one-stage revisions and 5.5% for two-stage revisions. At the five-year follow-up, the mortality rate for one-stage revisions was 25.5%, compared to 20.0% for two-stage revisions. No significant differences (p=0.30) were found in re-revision rates between one-stage and two-stage revisions after one year (one-stage 16.5% vs. two-stage 13.5%) or five years (one-stage 21.6% vs. two-stage 20.8%). For multiple revisions, the mortality differences were even larger (p<0.001), with a one-year mortality rate of 12.8% for one-stage RTHA and 5.7% for two-stage RTHA. Despite the excellent results of one-stage RTHA in the literature from individual large centers, it shows a significantly higher mortality rate with equal re-revision rate compared to two-stage revision in the nationwide care besides large centers. Significant differences can already be seen within the first year, indicating an increased perioperative mortality for one-stage revision, which might be explained by longer surgery duration, blood-loss and patient selection or maybe a lack of experience concerning proper surgical debridement for one-stage revision. This illustrates the need to establish centers for joint-revision surgery that provide interdisciplinary care and high case numbers to improve perioperative outcomes.
Implant fracture of modular revision stems is a major complication after total hip arthroplasty revision (rTHA). Studies looking at specific modular designs report fracture rates of 0.3% to 0.66% whereas fractures of monobloc designs are only reported anecdotally. It is unclear whether the overall re-revision rate of modular designs is higher and if, whether stem fractures or other revision reasons are responsible for this elevation. All revisions within 5 years after implantation of a revision stems (n0=13,900; n5=2506) were analysed using Cox regression with design (modular: n=17, monobloc: n=27), BMI, Sex and Elixhauser Score as independent variables. One stage and two stage revisions were analysed separately (1-stage: modular n= 7,102; monobloc n= 4,542; 2-stage: 1,551 / 704). The revision volume of the hospitals was also considered (low: <20 revisions, medium: 21–50 revisions, high: >50 revisions). For the 1-stage revisions, the re-revision risk after 4 years was 14,3% [13.2%, 15.5%] for monobloc and 17.4% [16.40%, 18.40%] for modular stems (p< 0.001). Stem fracture was the reason for re-revision in 2.4% of the modular (fracture rate 0.42%) and 0.6% of the monobloc revisions. The difference in re-revision rates between the designs was mainly due to differences in dislocation and stem loosening. For the 2-stage revisions, the revision risks for either design were similar (21.7% [18,5%, 25.4%] vs. 23.0% [20.8%, 25.4%]; p=0.05). Patient characteristics influenced the comparison between the two designs in the 1-stage group but very little in the 2-stage group. Modular revision stem fractures only contribute very minor to re-revision risk. In 2-stage revisions, no difference in overall re-revision rates between designs was observed. This might indicate that the differences observed for 1-stage procedures are due to differences between the patient cohorts, not reflected by the parameters available or surgeon choice.
Current diagnostic tools are not always able to effectively identify periprosthetic joint infections (PJIs). Recent studies suggest that circulating microRNAs (miRNAs) undergo changes under pathological conditions such as infection. The aim of this study was to analyze miRNA expression in hip arthroplasty PJI patients. This was a prospective pilot study, including 24 patients divided into three groups, with eight patients each undergoing revision of their hip arthroplasty due to aseptic reasons, and low- and high-grade PJI, respectively. The number of intraoperative samples and the incidence of positive cultures were recorded for each patient. Additionally, venous blood samples and periarticular tissue samples were collected from each patient to determine miRNA expressions between the groups. MiRNA screening was performed by small RNA-sequencing using the miRNA next generation sequencing (NGS) discovery (miND) pipeline.Aims
Methods
Despite higher rates of revision after total hip arthroplasty (THA) being reported for uncemented stems in patients aged > 75 years, they are frequently used in this age group. Increased mortality after cemented fixation is often used as a justification, but recent data do not confirm this association. The aim of this study was to investigate the influence of the design of the stem and the type of fixation on the rate of revision and immediate postoperative mortality, focusing on the age and sex of the patients. A total of 333,144 patients with primary osteoarthritis (OA) of the hip who underwent elective THA between November 2012 and September 2022, using uncemented acetabular components without reconstruction shells, from the German arthroplasty registry were included in the study. The revision rates three years postoperatively for four types of stem (uncemented, uncemented with collar, uncemented short, and cemented) were compared within four age groups: < 60 years (Young), between 61 and 70 years (Mid-I), between 71 and 80 years (Mid-II), and aged > 80 years (Old). A noninferiority analysis was performed on the most frequently used designs of stem.Aims
Methods
Antimicrobial suppression has shown to significantly improve treatment success of streptococcal periprosthetic joint infection (PJI) compared to 12-week standard antimicrobial therapy, however, only short-term follow-up was investigated. In this study we assessed the impact of suppression on the long-term outcome of streptococcal PJI. Consecutive patients with streptococcal PJI (defined by EBJIS criteria) treated 2009–2021 were prospectively included and allocated into standard and suppression (> 6 months) treatment group. Infection-free survival was assessed with Kaplan-Meier-method and compared between the groups with log rank test. Rates of infection-free, streptococcal infection-free and relapse-free status as well as tolerability of suppression were assessed.Aim
Method
Antibiotics have limited activity in the treatment of multidrug-resistant or chronic biofilm-associated infections, in particular when implants cannot be removed. Lytic bacteriophages can rapidly and selectively kill bacteria, and can be combined with antibiotics. However, clinical experience in patients with surgical infections is limited. We investigated the outcome and safety of local application of bacteriophages in addition to antimicrobial therapy. 8 patients (2 female and 6 male) with complex orthopedic and cardiovascular infections were included, in whom standard treatment was not feasible or impossible. The treatment was performed in agreement with the Article 37 of the Declaration of Helsinki. Commercial or individually prepared bacteriophages were provided by ELIAVA Institute in Tbilisi, Georgia. Bacteriophages were applied during surgery and continued through drains placed during surgery three times per day for the following 5–14 days. Follow-up ranged from 1 to 28 months.Aim
Method
Implant-related postoperative spondylodiscitis (IPOS) is a severe complication in spine surgery and is associated with high morbidity and mortality. With growing knowledge in the field of periprosthetic joint infection (PJI), equivalent investigations towards the management of implant-related infections of the spine are indispensable. To our knowledge, this study provides the largest description of cases of IPOS to date. Patients treated for IPOS from January 2006 to December 2020 were included. Patient demographics, parameters upon admission and discharge, radiological imaging, and microbiological results were retrieved from medical records. CT and MRI were analyzed for epidural, paravertebral, and intervertebral abscess formation, vertebral destruction, and endplate involvement. Pathogens were identified by CT-guided or intraoperative biopsy, intraoperative tissue sampling, or implant sonication.Aims
Methods
Psychological status may be an important predictor of outcome after periacetabular osteotomy (PAO). The aim of this study was to investigate the influence of psychological distress on postoperative health-related quality of life, joint function, self-assessed pain, and sports ability in patients undergoing PAO. In all, 202 consecutive patients who underwent PAO for developmental dysplasia of the hip (DDH) at our institution from 2015 to 2017 were included and followed up at 63 months (SD 10) postoperatively. Of these, 101 with complete data sets entered final analysis. Patients were assessed by questionnaire. Psychological status was measured by Brief Symptom Inventory (BSI-18), health-related quality of life was raised with 36-Item Short Form Survey (SF-36), hip functionality was measured by the short version 0f the International Hip Outcome Tool (iHOT-12), Subjective Hip Value (SHV), and Hip Disability and Outcome Score (HOS). Surgery satisfaction and pain were assessed. Dependent variables (endpoints) were postoperative quality of life (SF-36, HOS quality of life (QoL)), joint function (iHOT-12, SHV, HOS), patient satisfaction, and pain. Psychological distress was assessed by the Global Severity Index (GSI), somatization (BSI Soma), depression (BSI Depr), and anxiety (BSI Anx). Influence of psychological status was assessed by means of univariate and multiple multivariate regression analysis.Aims
Methods
Dual-mobility (DM) bearings are effective to mitigate dislocation in revision total hip arthroplasty (THA). However, data on its use for treating dislocation is scarce. Aim of this study was to compare DM bearings, standard bearings and constrained liner (CL) in revision THA for recurrent dislocation and to identify risk factors for re-dislocation. We reviewed 100 consecutive revision THAs performed for dislocation from 2012 and 2019. 45 hips (45%) received a DM construct, while 44 hips (44%) and 11 hips (11%) had a standard bearing and CL, respectively. Rates of re-dislocation, re-revision for dislocation and overall re-revision were compared. Radiographs were assessed for cup positioning, restoration of centre of rotation, leg length and offset. Risk factors for re-dislocation were determined by cox regression analysis. Modified Harris hip scores (mHHS) were calculated. Mean follow-up was 53 months (1 to 103). DM constructs were used more frequently in elderly patients (p=0.011) and hips with abductor deficiency (p< 0.001). The re-dislocation rate was 11.1% for DM bearings compared with 15.9% for standard bearings and 18.2% for CL (p=0.732). Revision-free survival for DM constructs was 83% (95% CI 0.77 – 0.90) compared to 75% (95% CI 0.68 – 0.82) for standard articulations and 71% (95% CI 0.56 – 0.85) for CL (p=0.455). Younger age (HR 0.91; p=0.020), lower comorbidity (HR 0.42; p=0.031), smaller heads (HR 0.80; p=0.041) and cup retention (HR 8.23; p=0.022) were associated with re-dislocation. Radiological analysis did not reveal a relationship between restoration of hip geometry and re-dislocation. mHHS significantly improved from 43.8 points to 65.7 points (p<0.001) with no differences among bearing types. Our findings suggest that DM bearings do not sufficiently prevent dislocation in revision THA for recurrent dislocation. Reconstruction of the abductor complex may play a key role to reduce the burden in these high-risk patients.
Synovial fluid D-lactate may be useful for diagnosing septic arthritis (SA) as this biomarker is almost exclusively produced by bacteria. We evaluated the performance of synovial fluid D-lactate and determined its optimal cut-off value for diagnosing SA. Consecutive patients with suspicion of septic arthritis were prospectively included. They underwent joint aspiration and synovial fluid was collected for culture, leukocyte count and D-lactate concentration (by spectrophotometry). Youden's J statistic was used for determining optimal D-lactate cut-off value on the receiver operating characteristic (ROC) curve by maximizing sensitivity and specificity.Aim
Method
Special acetabular polyethylene (PE) liners are intended to increase the stability of the artificial hip joint, yet registry studies on them are limited. The pupose of this study was to investigate differences in revision rates for mechanical complications in primary cementless total hip arthroplasty (THA) with standard and special PE acetabular liners in patients with ostheoarthritis. Data from the German Arthroplasty Registry (EPRD) between 2012 until 2020 were analysed. Patients with diagnosed ostheoarthritis of the hip without relevant prior surgeries, who received a primary cementless THA with a ceramic/PE bearing articulation were included. Cumulative incidences of revision for mechanical complications for Standard and 4 special PE liners (Lipped, Increased Offset, Angulated, Angulated|Increased Offset) were determined using the Kaplan-Meier Estimator. Confounding factors were investigated with a Cox proportional-hazards model. In total 151.104 cases were included. 7-year unadjusted revision-free survival for mechanical complications compared to Standard liners (97.7%) was lower for Angulated (97.4%), Lipped (97.2%) and Angulated|Increased Offset liners (94.7%), but higher for Increased Offset liners (98.1%). Risk of revision for mechanical complications was not significantly different between Standard, Lipped and Angulated liners. Increased Offset liners (HR=0.68; 95% CI=0.5–0.92) reduced, while Angulated|Increased Offset liners (HR= 1.81; 95% CI=1.38–2.36) increased the risk. Higher age at admission and an Elixhauser comorbidity index greater zero increased the risk, whereas a larger liner share slightly reduced the risk. Only the use of Increased Offset liners reduced the risk of revision for mechanical complications compared to Standard liners — other special liners did not.
Current guidelines consider analyses of joint aspirates, including leucocyte cell count (LC) and polymorphonuclear percentage (PMN%) as a diagnostic mainstay of periprosthetic joint infection (PJI). It is unclear if these parameters are subject to a certain degree of variability over time. Therefore, the aim of this study was to evaluate the variation of LC and PMN% in patients with aseptic revision total knee arthroplasty (TKA). We conducted a prospective, double-centre study of 40 patients with 40 knee joints. Patients underwent joint aspiration at two different time points with a maximum period of 120 days in between these interventions and without any events such as other joint aspirations or surgeries. The main indications for TKA revision surgery were aseptic implant loosening (n = 24) and joint instability (n = 11).Aims
Methods
The follow-up interval of a study represents an important aspect that is frequently mentioned in the title of the manuscript. Authors arbitrarily define whether the follow-up of their study is short-, mid-, or long-term. There is no clear consensus in that regard and definitions show a large range of variation. It was therefore the aim of this study to systematically identify clinical research published in high-impact orthopaedic journals in the last five years and extract follow-up information to deduce corresponding evidence-based definitions of short-, mid-, and long-term follow-up. A systematic literature search was performed to identify papers published in the six highest ranked orthopaedic journals during the years 2015 to 2019. Follow-up intervals were analyzed. Each article was assigned to a corresponding subspecialty field: sports traumatology, knee arthroplasty and reconstruction, hip-preserving surgery, hip arthroplasty, shoulder and elbow arthroplasty, hand and wrist, foot and ankle, paediatric orthopaedics, orthopaedic trauma, spine, and tumour. Mean follow-up data were tabulated for the corresponding subspecialty fields. Comparison between means was conducted using analysis of variance.Aims
Methods
Two stage revision is the most commonly used surgical treatment strategy for periprosthetic hip infections (PHI). The aim of our study was to assess the intra- and postoperative complications during and after two stage revision using resection arthroplasty between ex- and reimplantation. In this retrospective cohort study, all patients treated with a two stage revision using resection arthroplasty for PHI were included from 2008 to 2014. During the first stage, the prosthesis was removed resulting in a resection arthroplasty without the use a PMMA spacer. During second stage, (cemented or uncemented) reimplantation of the hip prosthesis was performed. The cohort was stratified into two groups according to the length of prosthesis-free interval (≤10 weeks and >10 weeks). Data on complications during explantation, prosthesis-free interval, reimplantation, and after reimplantation was collected. The overall complication rate between both groups was compared using the chi-squared test. The revision-free and infection-free survival was estimated using Kaplan-Meier survival analysis.Aim
Method
Treatment of enterococcal periprosthetic joint infections (PJI) is challenging due to heterogeneous pathogenesis, non-standardized management strategies and lack of biofilm-active antibiotics. Previous studies report treatment success from 50–76%. We evaluated the characteristics and outcome of enterococcal PJI, in particular the influence of antimicrobial treatment regimens. Consecutive patients with enterococcal PJI treated at two specialized orthopaedic institutions were retrospectively included from 2010 to 2017. PJI was defined by the proposed European Bone and Joint Infection Society (EBJIS) criteria. Adequate antimicrobial treatment was considered when the antibiotic was appropiate for the treatment of enterococcal bone infections (activity, dose, oral bioavailability, bone penetration). The treatment success (defined as no relapse of enteroccal infection) and clinical success(i.e. infection-free status) was evaluated and compared using Fishers exact test.Aim
Method
We included 26 patients suffering from We conclude that
The aim of the study was to assess the accuracy of the alpha defensin lateral flow test for diagnosis of periprosthetic joint infection (PJI) using an optimized diagnostic algorithm and three classification systems. In addition, we compared the performance with synovial fluid leukocyte count, the most sensitive preoperative test. In this prospective multicenter study we included all consecutive patients with painful prosthetic hip and knee joints undergoing diagnostic joint aspiration. Alpha defensin lateral flow test was used according to manufacturer instructions. The following diagnostic criteria were used to confirm infection: Musculoskeletal Infection Society (MSIS), Infectious Diseases Society of America (IDSA) and Swiss orthopedics and Swiss Society of Infectious Diseases (SOSSID). In the latter, PJI was confirmed when at least one of following criteria applied: macroscopic purulence, sinus tract, positive cytology of joint aspirate (>2000 leukocytes/μl or >70% granulocytes), histological proof of acute inflammation in periprosthetic tissue, positive culture (from aspirate, tissue or sonication fluid). Infection was classified as chronic, if symptom duration was more than 3 weeks or if infection manifested after more than 1 month after surgery. The sensitivity and specificity of the alpha defensin lateral flow test and leukocyte count in synovial fluid were calculated and compared using McNemar Chi-square test.Aim
Method
The incidence of hematogenous periprosthetic joint infections (hPJI) is unknown and the cases probably largely underreported. Unrecognized and untreated primary infectious foci may cause continuous bacteremia, further spread of microorganisms and thus treatment failure or relapse of infection. This study aimed at improving knowledge about primary foci and microbiological characteristics of this entity to establish preventive measures and improve diagnostic and therapeutic strategies to counteract hPJI. We retrospectively analysed all consecutive patients with hPJI, who were treated at our institution from January 2010 until December 2016. Diagnosis of PJI was established if 1 of the following criteria applied:(i) macroscopic purulence, (ii) presence of sinus tract, (iii) positive cytology of joint aspirate (>2000 leukocytes/μl or >70% granulocytes), (iv) significant microbial growth in synovial fluid, periprosthetic tissue or sonication culture of retrieved prosthesis components, (v) positive histopathology. PJI was classified as hematogenous if the following criteria were fulfilled additionally: (1) onset of symptoms more than 1 month after arthroplasty AND (2) i) isolation of the same organism in blood cultures OR ii) evidence of a distant infectious focus consistent with the pathogen.Aim
Method
Periprosthetic joint infections (PJI), caused by pathogens, for which no biofilm-active antibiotics are available, are often referred to as difficult-to-treat (DTT). It is unclear whether DTT PJI has worse outcome due to unavailability of biofilm-active antibiotics. We evaluated the outcome of DTT and non-DTT PJI managed according to a standardized treatment regimen. Patients with hip and knee PJI from 2013 to 2015 were prospectively included and followed-up for ≥2 years. DTT PJI was defined as growth of microorganism(s) resistant to biofilm-active antibiotics. The Kaplan-Meier survival analysis was used to compare the probability of infection-free survival between DTT and non-DTT PJI.Background
Methods
To assess the clinical characteristics, diagnostic tests and treatment strategies in orthopedic implant-associated infections (OIAI) caused by Cutibacterium spp. We retrospectively included consecutive patients with OIAI caused by Cutibacterium spp. treated at our institution from January 2012 to January 2017. OIAI was diagnosed when: (i) macroscopic purulence, sinus tract or exposed implant was present; (ii) acute inflammation in peri-implant-tissue was documented; (iii) Cutibacterium spp. grew in joint aspirate, ≥2 intraoperative peri-implant tissue samples or in sonication fluid of the removed implant (>50 CFU/ml).Aim
Method
The uncertainty of the biological effects of wear and corrosion from Metal-on-metal (MoM) implants has initiated a debate on their safety and use. Generally, the release of wear particles from MoM hip implants can clinically manifest in aseptic osteolysis. In our study, the effect of MoM-wear particles and particle originated Co and Cr ions on mesenchymal stromal cells (MSCs) was investigated [1]. The lead hypotheses were that (1) dissociated Co and Cr, originated from MoM-wear particles, accumulate in the bone marrow and (2) apparently impair the osteogenic function of local MSCs. This impairment could be one element contributing to the manifestation of periprosthetic osteolyses. The study was approved by the local ethical committee (EA1/194/13); all donors gave written informed consent. Blood (B), Synovial fluid (SF) periprosthetic tissue (PT) and bone marrow (BM) were collected from patients with at least one osteolytic lesion, undergoing a revision of a MoM hip implant. Patients undergoing primary THA served as controls. Metal wear particles were isolated from PT by enzymatic digestion and their size and shape characterized by transmission electron microscopy (TEM). Local and systemic levels of Co and Cr were analyzed by graphite furnace atomic absorption spectroscopy. MoM-MSCs and control-MSCs were isolated from BM for INTRODUCTION
METHODS
Despite the lack of data regarding the diagnostic validity of synovial aspiration in Girdlestone hips a Girdlestone-aspiration is often performed before reimplantation to detect a possible persistence of infection during two staged revision total hip arthroplasty (THA). The aim of this study was to assess the diagnostic performance of the synovial aspiration in Girdlestone hips, without a PMMA-Spacer, for the detection of infection persistence prior to THA reimplantation. Seventy four patients undergoing a two staged revision THA surgery between 2006 and 2013 were included in this retrospective cohort study. Both synovial cultures and CRP values were acquired before explantation of the THA and of the Girdlestone hip before reimplantation. An antibiotic holiday of 14 days was observed prior to synovial aspiration. A PJI was defined according to the following criteria: intraarticular presence of pus or a sinus tract, a periprosthetic membrane indicative of infection in the histological analysis, or a positive microbiological isolation in a minimum of two samples.Introduction
Methods
The efficacy of tranexamic acid (TXA) to reduce blood loss in various surgical procedures has been proven. However, there is little data about the effect of TXA on blood loss, rate of blood transfusion and thromboembolic events during periacetabular osteotomy (PAO). The reduction of blood loss during PAO promotes postoperative mobilization and reduces the risk of complications, associated with blood transfusions. The aim of the following study was to determine, if TXA can reduce both blood loss and the rate of blood transfusions. In addition we analyzed whether TXA was associated with an increased risk of thromboembolic events. A consecutive series of 96 PAO procedures was reviewed to compare the groups immediately prior to and following the routine implementation of TXA. The TXA group received a continuous infusion of TXA with a rate of 10mg/kg/h. The outcome was blood transfusion rate, total blood loss, length of hospital stay, and thromboembolic events.INTRODUCTION
METHODS
The main reasons for hip prosthesis failure are aseptic loosening and periprosthetic joint infection (PJI). The real frequency of PJI is probably largely underestimated because of non-standardized definition criteria, diagnostic procedure, treatment algorithm and other confounders. Therefore, data from joint registries are not reflecting the frequency of PJI and can be misleading; particularly low-grade PJI can be frequently misdiagnosed as aseptic failure. Therefore, prospective clinical studies with standardized protocol, comprehensive diagnostic procedure and sufficient follow-up should be performed. Sonication of explanted prosthesis is highly sensitive for detection of biofilms on prosthetic surface and allows quantitative analysis of biofilm formation. We hypothesize that by using sonication, ceramic components (BIOLOX®delta, BIOLOX®forte) will show higher resistance against biofilm adhesion compared to polyethylene (PE) and metal (CoCrMo). In this prospective multicentre study (level of evidence: Ia), we included all consecutive adults ≥18 years of age, who underwent explantation of the hip prosthesis for infection or aseptic reason. Excluded were patients in whom part of the prosthetic components were retained. A standardized and comprehensive diagnostic algorithm was applied, including sonication of all removed prosthetic components for qualitative and quantitative microbiological analysis (ultrasound bath 40 kHz, 1 W/cm2, 1 min). Individual components (metal, PE, ceramic) were separately placed in sterile boxes for investigation. All patients were simultaneously included in the European Prosthetic joint infection cohort (EPJIC, Background
Methods
A timely isolation of the causative bacterial species is of paramount importance in the treatment of periprosthetic joint infection (PJI). Sonication of the explanted endoprosthesis and the microbiological culture of sonicate fluid (SFC) has been proven to increase the rate of bacterial isolations in comparison to the conventional microbiological methods. The cultivation of aspired synovial fluid in blood culture bottles (BCB) has been shown to yield a higher rate of bacterial isolations and produce a lower rate of contaminants than cultivation on conventional agar plates. The primary aim of this study was to investigate whether the inoculation of BCB with sonicate fluid leads to a higher rate of bacterial isolations than the culture on agar plates. Secondly, we wanted to investigate whether the utilization of BCB leads to an earlier identification of the causative bacterial species. To our knowledge this is the first study to investigate the effects of BCB use on SFC. We performed a retrospective analysis comparing the results of the two different culture methods. To detect slow growing species all microbiological cultures, regardless of the culture method, were incubated for 14 days.Introduction
Methods
The leading cause for total hip arthroplasty (THA) revision remains aseptic loosening due to bearing wear. The younger and more active patients currently undergoing arthroplasty present unprecedented demands on THA-bearings. Ceramic-on-ceramic (CoC) bearings have consistently shown the lowest wear rates. The recent advances, especially in alumina CoC bearings, have solved many past problems and produced preferable results in vitro. Alumina ceramics are extremely hard, scratch resistant, biocompatible, offer a low coefficient of friction, superior lubrication and lower wear rates in comparison to other bearings in THA. The major disadvantage of ceramics used to be fracture. The new generation of alumina ceramics, has reduced the risk of ball fracture to 0.03–0.05%. The risk for liner fracture is even lower. Assuming an impingement-free component implantation, CoC bearings have major advantages over other bearing combinations. Due to the superior hardness, CoC bearings produce less third body wear and are virtually impervious to damage from instruments during the implantation process. A complication specific to CoC bearings is squeaking. Squeaking occurs if the friction in the joint articulation is sufficient to excite vibrations to audible magnitudes (due to loss of lubrication). The high range of reported squeaking (0.45% to 10.7%) highlights the importance of correct implant position. If a correct implant position can be guaranteed, then squeaking is rare and without clinical significance. The improved tribology and presumable resulting implant longevity make CoC the bearing of choice for young and active patients. Especially the alumina matrix (Biolox delta) offers increased burst strength and greater fracture toughness.
The endoprosthetic treatment of secondary osteoarthritis resulting from congenital hip dysplasia is difficult due to the small diameter of the acetabulum and the hypoplastic anterolateral bone stock. On the femoral side the increased femoral anteversion, insufficient femoral offset and proximal femoral deformities (mostly valgus deformities) as well as the small diameter and straight form of the intramedullary canal pose challenges. Careful preoperative planning is mandatory. The Crowe classification is usually used to describe these pathologies. In severe cases (Crowe 3 and especially Crowe 4) a shortening and derotating femoral osteotomy should be taken into account. Small acetabular components, acetabular augments, and modular femoral components must be available at all times. For acetabular fixation press-fit cups are preferred today, but excellent results were also described for threaded cups. The advantage of press-fit cups is the extensively documented and superior track record, but threaded cups allow for an easier reconstruction of the original hip center as well as slight medialization. As a result of medialization a reduction in polyethylene wear together with a low rate of loosening lead to very good long-term results in a younger patient population. Cementless straight stems are documented to be preferable for the small femoral diameter and the straight anatomic shape of the proximal femur. Nevertheless, the higher complication rate, especially the increased rate of nerve palsies, should be preoperatively discussed with the patient. The ideal bearing surface is currently unclear, ceramic-on-ceramic seems to be promising, although the longest data available support the use of metal-on-polyethylene.
The utilization of sonicate fluid cultures (SFC) has been shown to increase the detection rate of periprosthetic joint infection (PJI) in comparison to the use of conventional microbiological methods, because sonication enables a sampling of the causative bacteria directly from the surface of the endoprosthetic components. The hypothesis of this study is that not only will the detection rate of PJI be improved, but also the detection rate of polymicrobial infection in patients with total knee arthroplasty (TKA) revision surgery. 74 patients which underwent TKA revision surgery received a synovial aspiration, intraoperative tissue cultures, histological sampling of the periprosthetic membrane, and sonication of the explanted endoprosthesis. A PJI was defined according to the following criteria: presence of intraarticular pus or a sinus tract, positive isolation of causative bacteria in ≥2 microbiological samples or a histological membrane indicative of infection (type II or III periprosthetic membrane).Introduction
Material and methods
Acetabular retroversion has been implicated as a risk factor for the development of early hip osteoarthritis. In clinical practice standard osseous signs such as the cross-over sign (COS) and the posterior wall sign (PWS) are widely used to establish the diagnosis of acetabular retroversion on plain radiographs. Despite standardized radiological evaluation protocols, an increased pelvic tilt can lead to a misdiagnosis of acetabular retroversion in AP radiographs and 2D MR or CT scans. Previous studies have shown that the elimination of observer bias using a standardized methodology based on 3D-CT models and the anterior pelvic plane (APP) for the assessment of COS and PWS results in greater diagnostic accuracy. Using this method a prevalence of 28% for COS and 24% for PWS has been found in a cohort of patients with symptoms indicative of FAI, however the prevalence of both signs in asymptomatic adults remains unknown. This study therefore sought to establish the prevalence of the COS and PWS in relation to the APP in an asymptomatic population using a reliable and accurate 3 D-CT based assessment. A large pool of consecutive CT scans of the pelvis undertaken in our department for conditions unrelated to disorders of the hip was available for analysis. Scans in subjects with a Harris hip score of less than 90 points were excluded leaving a sample of 100 asymptomatic subjects (200 hips) for this study. A previously established 3D analysis method designed to eliminate errors resulting from variations in the position and orientation of the pelvis during CT imaging was applied to determine in order to assess the prevalence of the COS and PWS in relation to the APP. Here, the acetabuli were defined as retroverted if either the COS, PWS or both were positive.INTRODUCTION:
METHODS:
Sonicate fluid cultures (SFC) are more sensitive than conventional microbiological methods in identifying periprosthetic joint infections (PJI), because sonication enables a sampling of the causative bacteria directly from the surface of the endoprosthetic components. Because of their high sensitivity SFC can be positive while all other microbiological methods remain negative. It is therefore difficult to interpret a single SFC as being truly or falsely positive. The aim of this prospective study was to improve the interpretation of SFC in the diagnosis of PJI in patients after total hip arthroplasty through the use of multiple SFC. 102 patients of which 37 had a defined PJI according to the following criteria were included: intraarticular pus or a sinus tract, a periprosthetic membrane (PM) indicative of infection, or a positive microbiological culture in a minimum of 2 separate microbiological samples. A single positive microbiological sample was classified as false positive. In 35 patients multiple SFC were acquired from the separate endoprosthetic components.Introduction
Material and methods
Head sizes used in total hip arthroplasty (THA) has increased drastically from the original 22mm used by Charnley. This is due to two factors: the use of hard-on-hard materials for the bearing articulation and the increasing problem of dislocation. Hard-on-hard materials enable mixed or fluid film lubrication due to their good wettability. The development of a fluid film layer is encouraged by smaller surface pressures (larger area) and higher velocity at the articulating interface (larger radius), suggesting that larger diameters exhibit better lubrication and such less wear. This was effectivly proven in pre-clinical simulator studies and used as argument to increase the diameters of metal-on-metall and ceramic-on-ceramic bearings. Clinically the tribological advantage of larger diameters has not yet been shown. For hard-on-soft bearings the situation is different. Due to the bad wettability of Polyethylene (PE), the abrasive wear regime is dominant. This means that the longer wear path of a larger diameter will inevitably carry a larger amount of wear debris. Despite this relation, the heads used in combination with PE were also increased up to 40mm diameter, justified by the overall greatly reduced wear amount of the new generation(s) of cross-linked PE and favourable simulator results. First in-vivo studies have shown that larger heads carry larger amounts of wear particles. Whether this increase is relevant with respect to osteolysis is still unclear and will have to be shown in longer term studies. Larger heads require a larger “jumping” distance until they dislocate. Consequently the use of larger heads reduces dislocation rates, which was shown in multiple clinical studies. However, the reduction in dislocation rate achieved by increasing diameters varies greatly. Some centres achieve dislocation rates below 1% with 28mm heads, other centres require 36mm heads to achieve the same result. No study shows any further advantage with head diameters larger than 36mm. Despite their obvious biomechanical advantage with regard to stability, larger heads also have large disadvantages. Larger heads carry inevitably larger friction moments, requiring better anchoring of the components. In unfavourable conditions (start-up, break-down of lubrication film), friction moments of hard-on-hard bearings can get very high and reach or even exceed the losening torque of the head on the taper. Depending on the head impaction foce during assembly, the loosening torques amount to 8 to 17Nm. Movement at the head-taper connection possibly causes wear and increased corrosion at this interface. Larger head diameters also require thinner shells and/or liners, leading to problems with liner chipping or incomplete seating. Large head diameters have also lead to the use of sub-hemispherical cups with reduced covering surface, increasing the risk of fluid film break down due to edge loading if not well positioned. Finally, larger heads might give the surgeon a wrong feeling of security regarding a sub-optimal positioned cup. The question regarding “the optimal” head diameter is open for discussion and needs to consider the bearing material used. Head size should be limited to a reasonable compromise, which based on the information currently available, could be 36mm. Join the “36 and under” club.The tribological aspect
The biomechanical aspect
Skeletal muscle injuries often lead to severe functional deficits. Mesenchymal stem cell (MSC) therapy is a promising but still experimental tool in the regeneration of muscle function after severe trauma. One of the most important questions, which has to be answered prior to a possible future clinical application is the ideal time of transplantation. Due to the initial inflammatory environment we hypothesized that a local injection of the cells immediately after injury would result in an inferior functional outcome compared to a delayed transplantation. Twenty-seven female Sprague Dawley rats were used for this study. Bone marrow was aspirated from both tibiae of each animal and autologous MSC cultures obtained from the material. The animals were separated into three groups (each n=9) and the left soleus muscles were bluntly crushed in a standardized manner. In group 1 2×106 MSCs were transplanted into the injured muscle immediately after trauma, whereas group 2 and 3 received an injection of saline. Another week later the left soleus muscles of the animals of group 2 were transplanted with the same number of MSCs. Group 1 and 3 received a sham treatment with the application of saline solution in an identical manner. In vivo functional muscle testing was performed four weeks after trauma to quantify muscle regeneration. Maximum contraction forces after twitch stimulation decreased to 39 ± 18 % of the non injured right control side after crush trauma of the soleus muscles as measured in group 3. Tetanic stimulation showed a reduction of the maximum contraction capacity of 72 ± 12 % of the value obtained from intact internal control muscles. The transplantation of 2 x 106 MSCs one week after trauma improved the functional regeneration of the injured muscles as displayed by significantly higher contraction forces in group 2 (twitch: p = 0.014, tetany: p = 0.018). Local transplantation of the same number of MSCs immediately after crush injury was able to enhance the regeneration process to a similar extent with an increase of maximum twitch contraction forces by 73.3 % (p = 0.006) and of maximum tetanic contraction forces by 49.6 % (p = 0.037) compared to the control group. The presented results underline the effectivity of MSC transplantation in the treatment of severe skeletal muscle injuries. The most surprising finding was that despite of the fundamental differences of the local environment into which MSCs had been transplanted, similar results could be obtained in respect to functional skeletal muscle regeneration. We assume that the effect of the MSC after immediate injection can partly be explained by their known immunomodulatory competences. The data of our study provide evidence for a large time window of MSC transplantation after muscle trauma.
Total hip arthroplasty is a challenging problem in case of high hip dislocation. In order to reduce the hip, a femoral shortening osteotomy is necessary to prevent damage to the neurovascular structures. In this study we present the mid-term results of a simple technique of simultaneous derotating and shortening osteotomy of the femur without the necessity of additional osteosynthesis. In this retrospective study we included 28 patients with high hip dislocation. In these patients 30 consecutive cementless primary total hip arthroplasties with femoral shortening osteotomy were performed. 20 cases were previously operated. All patients were clinically and radiologically followed up after a mean of 4.5 years (range 2 – 5.7 years). Time point of consolidation was determined on consecutive radiographs for each patient. The average operative time was 116 minutes (range 65 to 150 minutes). There were no intraoperative complications. Postoperatively no femur fractures, no pseudarthroses and no pareses were observed. The mean consolidation time of the osteotomy was 4.4 months. At the time of follow-up, one aseptic loosening had been verified. In this case a very small stem (size 03) had been used. The mean Merle d’Aubigne score for the unrevised hips improved from 8.2 points preoperatively to 15.1 points at follow-up. In conclusion the presented technique allowed an easy and fast implantation of total hip arthroplasty in patients with high hip dislocation. The Zweymueller stem design with its rectangular cross-section seems responsible for the sufficient stability of the osteotomy resulting in a short consolidation time. Any additional osteosynthesis is obsolete. This leads to additional advantages including a short duration of surgery and a low complication rate. The good clinical results are attributable to the fact, that by shortening the femur, the physiological hip joint biomechanics could be approximated. The mid-term results of the described technique are very promising.
While significant component malalignment in the frontal and sagittal plane may lead to early loosening and pain, even small errors in the rotational component alignment are not tolerated due to its complex impact on knee joint kinematics and especially the patella tracking. It is accepted that navigated implantation of total knee arthroplasties improves accuracy in the frontal plane but it is yet unclear weather navigation leads to a more precise rotational component alignment. The study evaluated the influence of navigated implantation on femoral and tibial component alignment. In a prospective randomized study 32 navigated and 28 conventionally implanted total knee arthroplasties were evaluated through a postoperative CT scan. In all cases the femoral component was referenced to the surgical epicondylar axis and the tibial component was referenced to the medial third of the tibial tuberosity. The angles between these bone landmarks and the components were measured on the CT scans and compared between both study groups. The rotational malalignment of the femoral component in the conventional operating technique was 0.1° ± 2.2° (range 3.3° of internal rotation and 5.0° of external rotation). Navigated implanted femoral components showed a malalignment of 0.3° ± 1.4° (range 4.7° of internal rotation and 2.2° of external rotation), the difference was not significant. The rotational malalignment of the tibial component in the conventional technique was 7.5° ± 6.0° (range 27.1° of internal rotation and 15° of external rotation). Navigated implanted tibial components showed a malalignment of 6.9° ± 4.7° (range 21.2° internal rotation and 11.0° external rotation), the difference was not significant. In conclusion the use of a navigation system did not improve the rotational alignment of the tibial or femoral component if only one bone landmark was used. Taking the relatively small errors of a navigation machine into account the error is attributable to the surgeon, who seems to be unable to precisely define bone landmarks. More than one landmark (e.g. additionally Whiteside’s line, posterior condyles, flexion gap for the femur and ankle joint for the tibia) should be used to define the component rotations. Consideration of different rotational landmarks is best done with a navigation system that, in contrast to the manual technique, has the possibility to show the degree of deviation of the components from each landmark.
The development of iron oxide nanoparticles, which are taken up and endosomally stored by stem cells, allows the evaluation of cellular behaviour in the muscle with the use of magnetic resonance imaging (MRI). Previous work has shown that labelling does not affect the proliferation and neurogenic differentiation capacity of embryonic stem cells. In the present study we are currently investigating the in vivo distribution and migration of locally transplanted MSC after blunt muscle trauma in a rat model.
The hypothesis of the current study was that the loading of the proximal femur is altered significantly by the surgical approach. The change in long-term periprosthetic bone mineral density in relation to the alteration of the musculature after the anterolateral (Group A) and transgluteal approaches (Group B) has been compared. Group A comprised 35 hip joints (30 patients) and Group B 47 hip joints (37 patients). No significant differences were seen between groups in respect to age, gender, or diaphyseal BMD distribution and in respect to average stem size in a Wilcoxon test. Measurement of BMD in femoral Gruen Zones I, II, VI, and VII revealed a significant bone loss in Group B compared with Group A; however the functional outcome showed no significant differences between the two groups postoperatively. Analysis of proximal femoral loading by means of a validated musculoskeletal model showed a considerable redistribution of the musculoskeletal loading across the hip during walking and stair climbing after a transgluteal compared with an anterolateral surgical approach. The muscular damage caused by the surgical approach seems to have a significant influence on the long-term bone loss and the initial postoperative loading of the proximal femur.
Despite all gain of knowledge, septic and aseptic loosening of endoprostheses still remain unsolved problems. In loosening of joint arthroplasty a periprosthetic membrane is found between the bone and the loosened implant. The characteristics of the membrane are influenced by the process that leads to the loosening of the endoprosthesis. The aim of the study was to introduce a classification system that enables a standardized diagnostic evaluation and helps to determine the aetiology of the loosening process. Based on histomorphological criteria and polarized light microscopy, four types of periprosthetic membranes were defined: periprosthetic membranes of the wear particle type (type I), periprosthetic membranes of the infectious type (type II), periprosthetic membranes of the combined type (type III), and periprosthetic membranes of the indifferent type (type IV). Periprosthetic membranes of 268 patients were analyzed according to the defined criteria. The interobserver reproducibility was sufficient (95%). The correlation between histopathological and microbiological diagnosis was high (89%, p<
0,001). The four types of periprosthetic membranes showed a significantly different time of revision. This classification system enables a standardized diagnostic procedure. It therefore is a basis for further studies concerning the etiology and pathogenesis of prosthesis loosening. The reliability of this histomorphological examination in diagnosing infections is currently reviewed.
The objective of this study was to evaluate the suitability of autologous periosteal cells for spinal fusion in humans. Lumbar spondylodesis has a slow consolidation rate with a consecutive lengthy period of inability to work and the risk of non-union. This study evaluates the applicability of a cell-matrix construct for spinal fusion using clinical and radiological parameters. All experiments were approved by the university ethics committee. Lumbar spondylodesis of the segments L4/5 or L5/S1 was performed in 20 healthy patients (mean age 45 years). Indication for surgery was DDD resistant to conservative treatment. 10 weeks before fusion operation, a piece of periosteum was harvested from the proximal tibia of the patient. The material was chopped and digested. In the washed cell suspension cell number and viability were determined. The viability was greater 90% before seeding. After four passages, the cells were mixed with human fibrinogen, and soaked into polymer fleeces. Polymerization was achieved by adding thrombin. The 3D constructs were cultured for 3 weeks. The final application form were chips of 2mm thickness and 8mm diameter. Spondylodesis was performed using a ventral approach for implantation of 2 titanium cages and a dorsal approach for application of a transpedicular screw-rod system (Medtronic, Sofamor Danek). In 10 patients the chips were implanted ventrally within the cage. The other 10 patients obtained a dorsal intertransverse transplantation of the chips. Pre-operative, 3, 6, 9, and 12 months after surgery a clinical examination was performed, radiographs, and functional scores were obtained. No implant associated side effects were noted. Especially, signs of infection or allergic reaction have not been observed. The harvest sites of all patients presented symptom-free after 3 months. The rate of consolidation was 60% after 6 months, 90% after 9 months, and 100% after 12 months. No clinical or radiological signs for implant failure or malpositioning were observed. 90% of the patients were satisfied with the outcome of the surgery. Cultured autologous periosteal cells are a suitable material for anterior as well as posterior spinal fusion in humans. They may accelerate the rate of fusion and reduce the risk of non-union. Rate and velocity of osseous consolidation need to be compared to that of patients treated with iliac crest autograft. A major advantage might be the lower rate of graft site morbidity.