Abstract
Aim
Synovial fluid D-lactate may be useful for diagnosing septic arthritis (SA) as this biomarker is almost exclusively produced by bacteria. We evaluated the performance of synovial fluid D-lactate and determined its optimal cut-off value for diagnosing SA.
Method
Consecutive patients with suspicion of septic arthritis were prospectively included. They underwent joint aspiration and synovial fluid was collected for culture, leukocyte count and D-lactate concentration (by spectrophotometry). Youden's J statistic was used for determining optimal D-lactate cut-off value on the receiver operating characteristic (ROC) curve by maximizing sensitivity and specificity.
Results
A total of 155 patients were included. Using institutional criteria, 21 patients (14%) were diagnosed with SA and 134 (86%) patients with aseptic arthropathy, out of which 43 (27%) had osteoarthrosis, 80 (52%) had rheumatic arthropathy and 11 (7%) reactive arthritis. The optimal cut-off of synovial fluid D-lactate to differentiate SA from aseptic cases was 0,035 mmol/l. Synovial fluid D-lactate had a sensitivity 90% (95% CI: 70–99%) and specificity 87% (95% CI: 80–92%) compared to leukocyte count with sensitivity 81% (95% CI: 60–95%) and specificity 83% (95% CI: 76–90%). Culture was positive in only 17 (80%) out of 21 patients with SA.
Conclusions
The synovial fluid D-lactate showed high sensitivity and specificity for diagnosis of SA which was higher than the current gold standard of diagnosis (culture and leukocyte count). The high sensitivity makes this biomarker useful as a point-of-care screening test for SA.