Advertisement for orthosearch.org.uk
Orthopaedic Proceedings Logo

Receive monthly Table of Contents alerts from Orthopaedic Proceedings

Comprehensive article alerts can be set up and managed through your account settings

View my account settings

Visit Orthopaedic Proceedings at:

Loading...

Loading...

Volume 96-B, Issue SUPP_18 December 2014 The Indian Orthopaedic Society (UK) (IOSUK)

C. Luke S. Kamalanathan A. Doorgakant R. Sanger

In recent years, many changes have taken place regarding agents used for chemical thromboprophylaxis in elective joint replacement. Enoxaparin, Rivaroxaban, Dabigatran and Apixaban are all now recommended in NICE CG92 and their use varies nationally. Whilst data exists comparing oral anticoagulants to Enoxaparin, there is little data on the comparative efficacy of the individual oral anticoagulants.

This study analyses data from Warrington Hospital, where each of the above oral anticoagulants was used trustwide in 3 successive years following hip and knee arthroplasty. We analysed similar 4–5 month periods in 2010(Rivaroxiban), 2011(Dabigatran) and 2012(Apixaban). The study was done prospectively and data was collected contemporaneously. The total sample size was 475 patients. Data was collected through electronic hospital patient records. Patients were excluded if data was incomplete. We defined our primary outcome as any complication requiring the drug to be omitted or stopped.

We found that for Rivaroxaban, 7 of 129 patients had the drug omitted or stopped (5.4%, 95% confidence interval 1.0–9.8), for Dabigatran 19 of 150 patients, (12.7%, 95% confidence interval 6.4–19.0) and for Apixaban 10 of 196 patients (5.1%, 95% confidence interval 0.9–9.3). For Rivaroxaban and Apixaban, there were no confirmed thromboembolic events; however, for Dabigatran, there were six VTEs. All three had bleeding complications, which were well below the figures published for Enoxaparin. Apixaban registered the lowest rate in our study (5.1%). This data suggests that Apixaban is a safe oral anticoagulant in elective total knee and hip replacement.


K. Somasundaram M. Awogbadhe V. Kavarthapu PLS Li

Osteonecrosis of femoral head is well known and recognised complication in Sickle cell disease patients. Due to the severity of the Osteonecrosis, hip pain is major limiting factor for these patients requiring total hip arthroplasty in relatively young age. We studied and report our results in total hip arthroplasty of sickle cell patients.

We studied 80 patients from our combined Orthopaedic & Haematology Sickle cell clinic. Twenty four patients had painful Osteonecrosis with secondary osteoarthritis of hip and underwent total hip arthroplasty. Three patients had bilateral hip replacements. A total of twenty seven replacements were studied retrospectively. 19 patients had uncemented (Corail/Pinnacle), 5 patients had hybrid(Pinnacle/Exeter) and 3 patients had cemented(Exeter) total hip arthroplasties respectively.

The patients were serially followed up for clinical and radiological assessments for loosening. Oxford hip score (OHS) was used to assess the functional outcome. The average age of the patients at the time of surgery was 38.4 (Range – 20 to 59 years. The average follow up was 5.1 years (Range – 6 months to 10 years). There were 13 female and 11 male patients. The average oxford hip score was 38.07 with 10% infection rate and 11% aseptic loosening.

Arthroplasties carry high risk in patients with sickle cell disease. We report lower rates of infection and loosening rates compared to the earlier studies. Combined Haematological and Orthopaedic team input is optimal during assessment, surgery, peri-operative period and follow up. Our results of total hip replacements in sickle cell disease patients are good.


K. Somasundaram C.P. Huber V. Babu H. Zadeh

Optimal surgical management of proximal humeral fractures remains controversial. We report our experience and the study on our surgical technique for proximal humeral fractures and fracture-dislocations using locking plates in conjunction with calcium sulphate augmentation and tuberosity repair using high strength sutures. We used the extended deltoid-splitting approach for fracture patterns involving displacement of both lesser and greater tuberosities and for fracture-dislocations.

We retrospectively analysed 22 proximal humeral fractures in 21 patients. 10 were male and 11 female with an average age of 64.6 years (Range 37 to 77). Average follow-up was 24 months. Fractures were classified according to Neer and Hertel systems. Pre-operative radiographs and CT scans in three and four-part fractures were done to assess the displacement and medial calcar length for predicting the humeral head vascularity. According to the Neer classification, there were 5 two-part, 6 three-part, 5 four-part fractures and 6 fracture-dislocations (2 anterior and 4 posterior). Results were assessed clinically with DASH scores, modified Constant & Murley scores and serial post-operative radiographs.

The mean DASH score was 16.18 and modified Constant & Murley score was 64.04 at the last follow-up. 18 out of 22 cases achieved good clinical outcome. All the fractures united with no evidence of infection, failure of fixation, malunion, tuberosity failure, avascular necrosis or adverse reaction to calcium sulphate bone substitute. There was no evidence of axillary nerve injury. The CaSO4 bone substitute was replaced by normal appearing trabecular bone texture at an average of 6 months in all patients.


S. Thati S. Aranganathan M. Ganapathi

Patient specific instrumentation (PSI) is the latest advancement in total knee arthroplasty (TKA), which claims to improve alignment, simplify the surgical process, forecasts the component size and reduces the operating time. We discuss our experience of preoperative planning using default settings and making changes where necessary.

We analysed prospectively collected data in 100 consecutive PSI knee replacements (Zimmer®) performed in our institute during the period February to August 2012. All patients underwent MRI scans of the ipsilateral hip, knee and ankle joints. From the images, Materialise® (Leuven, Belgium) provided 3D model of the knee on which preoperative planning was done using PSI software. All default plans were checked and appropriate changes were made before the senior author approved final plan for preparation of patient specific moulds.

We made 636 changes (6.36 changes per knee) preoperatively from the default settings. In only 4% of the patients, the primary cuts needed revision. Thus in 96% of the cases, the primary cuts allowed optimal alignment and gap balancing with appropriate soft tissue release. Our preoperative planning predicted 99% of femoral and 98% of tibial component sizes definitively implanted.

Our results show the importance of the surgeon's input in approving preoperative planning with this technique.


H.L.M. Williams T.R. Madhusudhan A. Sinha

TER is a viable surgical option in patients with advanced RA with painful stiff elbows. We retrospectively analysed 22 TER performed in 21 patients over a 12 year period by a single surgeon, with a mean follow up of 64 months (10–145). Disability of the arm, shoulder and hand (DASH) scores were performed pre-operatively and post-operatively in patients through postal questionnaires. The mean age was 59.1 years (32–78). There were 12 women and 9 men. The mean pre-operative DASH score was 72.3 (45.0–91.7) and post-operatively improved to 46.8 (21.7–94.2). Complications included infection, peri-operative fracture, peri-prosthetic fracture and aseptic loosening. There were 6 revisions performed, 2 for peri-prosthetic fracture, 2 for infection, 1 for intra-operative fracture and 1 for symptomatic aseptic loosening. Four patients had died due to unrelated causes. The 10 year survival rate with symptomatic aseptic loosening as the end point was 93% and revisions for all reasons was 69%. Follow up radiographs (in those without revision) were reviewed and 10 had satisfactory positioning of the prosthesis, 5 had loosening of the humeral or radial component and 1 had inadequate cement mantle but was clinically asymptomatic. TER is a rewarding procedure in with advanced RA. Our results are comparable to other published studies.


J. N. Lamb M. Varghese B. Venkateswaran

This study aims to correlate Oxford shoulder score (OSS) to EQ5D score in healthy patients presenting to a shoulder clinic with shoulder pain.

OSS and EQ5D scores were collected prospectively from 101 consecutive patients presenting with shoulder pain in a shoulder clinic at one specialist centre. Patients with ASA > 2 and other significant joint arthritis were excluded from the study. Scores were collected from electronic patient records. Spearman's rho correlation of oxford shoulder scores and EQ5D scores was completed.

Mean age of subjects was 51.8 (range 19.1–81.9) years, 55 of 101 subjects were men (54%). Median OSS was 26 (range 3–48) and median EQ5D score was 0.76 (range 0–0.76). Correlation for all patients was 0.624 (Sig p<0.001).

This study demonstrates a strong correlation between Oxford shoulder scoring and EQ5D in a fit and well shoulder surgery clinic population. It is possible that Oxford shoulder scores may be a useful indicator of quality of life in healthy shoulder clinic patients presenting with shoulder pain.


TR Madhusudhan NR Clay

Dupuytren's disease is often disabling and traditionally has been managed with various surgical methods, with recurrence rates up to 50 %. Recently clostridial collagenase injection has been licensed for use in the NHS.

We prospectively analysed the results of clostridial collagenase injection in 62 patients with varying degrees of Metacarpo phalangeal (MCP) and Proximal interphalangeal (PIP) joint contractures. There were 48 males and 14 females with an average age of 66 years. The average MCPJ and PIPJ deformities were 33 and 17 degrees respectively. Following the infiltration and subsequent manipulation under local anaesthetic and night splinting for 3 months, patients were followed up at 4 weeks and 6 months. Deformities persisted in 5 patients and later required surgical correction. MCPJ deformities were more amenable for correction than PIPJ and in those with recurrence. The average residual deformity was 7 degrees. Common complications include bruising, swelling, pain not responding to routine analgesia, lymphangitis and skin break in some but none required any additional interventions. 14 patients had completed 6 month follow up and there was no recurrence. Subjective assessment through questionnaires revealed high patient satisfaction rate with early return to work within 1 week in most patients. Patients with previous operations preferred injections over operative correction. Collagenase injections are effective in deformity correction with higher satisfaction rate and low morbidity. Early results are encouraging but long term follow up is required to assess recurrence rates.


A.A. Shetty S-J. Kim V. Shetty P. Bliagi

We describe a novel single stage arthroscopic repair procedure for articular cartilage defect in the knee. The aim of the study was to evaluate the clinical and radiological outcomes at two years.

The pre-clinical study involved two groups of New Zealand rabbits, treated with microfracture alone and microfracture combined with fibrin gel and concentrated bone marrow aspirate cells (BMAC) application. New cartilage from both groups was studied with histological staining, immunohistochemistry and electron microscopy. The fibrin gel-BMAC group scored better than the microfracture group on all counts.

This is a prospective study of 30 patients with symptomatic ICRS grade III/IV chondral defects, ranging from 2–8 cm2, which were assessed clinically and radiologically. The surgical procedure involved debridement of the lesion, microfracture and arthroscopic application of concentrated BMAC with fibrin gel under CO2 insufflation. Patients underwent morphological MRI, quantitative T2*-mapping and d-GEMRIC scan. Clinical assessment was carried out using the Lysholm, IKDC and KOOS scores while radiological assessment used the MOCART score.

At 2 year follow-up, Lysholm score was 80.1, as compared to 50.8 pre-operatively (p < 0.05). KOOS (symptomatic) was 92.1, as compared to 65.7 pre-operatively. IKDC (subjective) was 83, up from 39 preoperatively. The mean T2* relaxation-times for the repair tissue and native cartilage were 29.1 and 29.9 respectively. Average MOCART score for all lesions was 72.

Our technique shows encouraging clinical and radiological results. The morphological MRI shows good cartilage defect filling and the biochemical MRI (T2*-mapping) suggests hyaline like repair tissue.


S. Aranganathan C. Carpenter D.P. Thomas S. Hemmadi D. O'Doherty

Complex congenital foot deformities pose a challenge to the surgeon due to poor results after extensive surgery. We report the clinical outcomes of children with complex congenital foot deformities treated with UMEX® (Universal mini-external fixator System) frames.

This is a prospective review of our experience in patients treated in this way, from 2004 to 2011. The indications for treatment included resistant/recurrent Congenital Talipes Equino Varus (CTEV), cavo-varus deformity secondary to Charcot-Marie-Tooth disease, arthrogryposis, fibular hemimelia and other congenital abnormalities. A total of 32 children (35 feet) have been treated, out of which 22 were male and 10 were female patients. Age at surgery ranged from 3 to 15 years (median age – 7 years). Three patients underwent bilateral procedures; the reminder (29 patients) underwent unilateral foot operations. Twenty-eight patients had undergone previous surgery including soft-tissue and/or bony corrective procedures.

The frames were removed at an average of 69 days after application, and the patients spent a further 6 weeks in a walking cast. Good functional outcomes were noted in 26 patients in the first postoperative year and in 19 patients in the fifth postoperative year. Further operations were needed in 10 patients. Complications occurred in 10 patients, predominantly pin-site infections and 1 case of bony overgrowth at pin-site and 1 of proximal tibio-fibular diastasis.

This is a simple fixator to use with a short learning curve. In groups of patients with complex congenital abnormalities, we achieved good functional outcome with low-complication rates.


K. Ghosh S. Robati A. Shaheen M. Solan

The MediShoe (Promedics Orthopaedics Ltd, Glasgow) is a specific post-operative foot orthosis used by post-operative foot and ankle patients designed to protect fixations, wounds and maximise comfort. The use of rigid-soled shoes has been said to alter joint loading within the knee and with the popular use of the MediShoe at our centre in post operative foot and ankle surgery patients, it is important to ascertain whether this is also true.

An analysis of the knee gait kinetics in healthy subjects wearing the MediShoe was carried out. Ten healthy subjects were investigated in a gait lab both during normal gait (control) and then with one shoe orthosis worn. Force plates and an optoelectronic motion capture system with retroreflective markers were used and placed on the subjects using a standardised referencing system. Three knee gait kinetic parameters were measured:- knee adduction moment; angle of action of the ground reaction force with respect to the ground in the coronal plane as well as the tibiofemoral angle. These were calculated with the Qualisys software package (Gothenburg, Sweden).

A two-tailed paired t-test (95% CI) showed no significant difference between the control group and the shoe orthosis-fitted group for the knee adduction moment (p = 0.238) and insignificant changes with respect to the tibiofemoral angle (p = 0.4952) and the acting angle of the ground reaction force (p = 0.059).

The MediShoe doesn't significantly alter knee gait kinetics in healthy patients. Further work, however is recommended before justifying its routine use.


S.V. Sonanis S. Kumar N. Deshmukh

Auto-CAD study is done to observe effects of head neck ratio (HNR) in hip replacements.

Total hip replacement joints were reconstructed on CAD with increasing diameter of the head keeping neck diameter constant in 1997. Simulation was done and Range of Movement (ROM), impingement and stability of the hip joint was noted. A graph was plotted with Head Neck Ratio (HNR) on X-axis and ROM on Y-axis. It was observed that as the HNR increases the ROM of the joint is increased, impingement is reduced and stability is also increased. It is also observed that diameter of the head and neck is more important than considering only head diameter of the hip joint. The graphical analysis confirms that different diameters of the head may have same HNR depending on the neck diameter. So even in smaller diameter head the HNR may be more due to smaller diameter neck and may be more advantages than larger diameter head with bigger neck having smaller HNR.

We conclude that HNR is more important than the head diameter alone in hip replacements.


S.V. Sonanis S. Kumar K. Bodo N.V. Deshmukh

Tunning fork lines (TFL) were drawn on ankle anterior-posterior radiographs to assess the talar shift in ankle fractures.

A 3-D ankle joint reconstruction was prepared by mapping normal ankle joint using auto CAD in 1997. TFL were drawn using normal anatomical landmarks on saggital, coronal and transverse planes. The ankle joint anatomical relationship with talus was studied in various rotation simulating radiographic anterior-posterior views and talar shift was studied. Between 2006 and 2012 on antero-posterior view of ankle radiographs and PACS, TFL were drawn. The premise is that in a normal radiograph the superior-lateral dome of the talus lies medial to the handle of TFL, and in ankle with talar shift the dome of the talus would cross this line laterally. In two district hospitals 100 radiographs were observed by 4 observers in 67 males and 33 females with mean age of 49 (15–82) years. The TFL confirmed talar shift with sensitivity of 99.2 % showing talarshift and inferior tibio-fibular ankle diastasis.

We conclude that in ankle anterio-posterior view it is possible to comment on the talar shift and diastasis of the ankle joint, even if proper ankle mortise views were not available.


M.R. Nademi K.K. Naikoti W. Salloum H. Wynn Jones A. Clayson N. Shah

Stoppa approach has recently been adapted for pelvic surgery as it allows direct intra-pelvic reduction and fixation of the quadrilateral plate and anterior column. We report our early experience, indications and complications with this exposure introduced in 2010 in our tertiary unit.

A Retrospective review of all Stoppa approaches in pelvic-acetabular fixations was performed from a prospectively maintained database.

Of the 25 patients, mean age 40 years (range 15–76), who underwent pelvic-acetabular fixation using Stoppa approach, 21 patients had mean follow up of 7.3 months (1–48 months). All except 24% of patients had one or more additional systemic injury some requiring additional surgery. There were 6 acetabular fractures, 13 pelvic ring injuries and 6 combined fractures. Mean injury-surgery interval was 9 days (range 3–20). 8 patients had an isolated Stoppa approach whilst the remaining others also had an additional approach. Mean surgical time was 239 minutes. Anatomical reduction was achieved in 96% (24/25) cases. There was 1 minor intra-operative vascular injury, repaired immediately successfully, and no late wound infections, or other visceral complications. One patient reported new onset sensory numbness which resolved after the first review. Two patients reported erectile dysfunction thought to be caused by the initial injury. One patient had asymptomatic plate loosening. None required revision surgery.

Despite the obvious learning curve, we found this approach safe and it did not compromise accuracy of reduction in well selected patients, but early surgery within 10–14 days is recommended to aid optimal reduction.


R Kakkar J Ramaskandhan K Bettinson K Muthumayandi S Kometa E Lingard J P Holland

Birmingham Metal-on-metal total hip resurfacing (BHR) is a bone-conserving option for patients with advanced articular damage. While the outcomes of Total Hip Replacement (THR) are well documented, there is a paucity of literature comparing the patient reported outcomes of BHR versus THR. This study aims to compare the patient reported outcomes for an impact on quality of life between patients who had a BHR vs. THR after correcting for selection bias.

Patients who underwent a BHR or THR between July 2003 and December 2006 were included. Patient questionnaires included demographic details, co-morbidities, WOMAC, SF-36 Scores. In addition, a 4 point Likert scale was used to measure satisfaction post-operatively. The above data was collected pre-operatively and at 1, 2, 3 and 5 years post-operatively. Data was analysed with SPSS (version 19) software package. All analysis was adjusted for Age, gender, Co-morbidity and pre-operative score by using Multivariate regression analysis using a General Liner Model to rule out the effect of these predictors on outcomes between groups.

337 patients were included (205 for THR and 132 for BHR). BHR patients were younger than THR patients (49 vs. 67 years, p<0.01), were more likely to be male (68% vs. 42% of THR, p<0.01), reported fewer co-morbidities (1.06 vs. 1.59, p<0.01). BHR patients reported better WOMAC pain and function scores at 5 years (p<0.05). For SF-36 scores, BHR patients reported higher scores for all 8 domains at 1 year and 5 year follow up (p<0.05). BHR patients reported higher satisfaction than THR group for return to Activities of Daily Living and Recreational activities at 1 and 5 years (p<0.05)

After correction for patient variability, BHR patients reported better improvement in pain and function and enjoyed a better quality of life in relation to return to ADL and recreational activities over to 5 years post-surgery.


S. Thambapillay S. Kornicks G. Chakrabarty

Severe deformity and bone loss in patients with degenerative changes of the knee present a challenging surgical dilemma to the knee surgeon. We present the outcome following complex primary total knee replacements at our unit over 12 years undertaken by a single surgeon.

Method:

65 patients were followed up prospectively with regards to their pre- and post-operative Oxford knee scores, diagnoses, preoperative deformity, bone loss, surgical technique, type of implant used, bone substitutes, and perioperative, or long term complications. These patients were followed up annually.

Result:

70 complex primary total knee replacements were performed in 65 patients. The mean age was 70.5 years and the mean follow up was 62.4 months. Sleeve/wedge augmentation, and stemmed implant (Sigma®TC3- DePuy) were used in general. Bone grafting was utilized for contained bone defects. All except 4 patients were allowed to fully weight bear immediately postoperatively. The mean range of flexion was 112.5 degrees at their last follow up. The mean preoperative Oxford Knee Score was 12.8, and 41.5 postoperatively. 89.4% of patients had either an excellent or good, and the rest a fair outcome. Radiological appearance has been satisfactory in all patients at subsequent follow up, with no evidence of implant loosening. None required revision surgery. 6 patients required blood transfusion postoperatively. 2 patents developed symptomatic deep vein thrombosis and a further 2 had pulmonary embolus


M. Siebachmeyer S. Lakkol K. Boddu M. Al-Kooheji A. Lingham V. Kavarthapu P.L.S Li

Hip simulator studies have shown reduced hip offset can cause microseparation and increased wear in hard-on-hard hip bearings. However this has not been analysed yet in vivo. We studied the effect of reduced hip offset on serum metal ion levels in patients with metal-on-metal (MoM) hip arthroplasty.

From all patients who underwent unilateral MoM bearing hip arthroplasty between 2005 and 2009, 63 patients had complete clinical evaluation, measurement of serum chromium and cobalt ion levels as well as biomechanical measurements on pre- and post operative radiographs (cup inclination, head inclination, change in hip offset and change in hip length.)

Ten arthroplasties were revised due to adverse metal reaction and six patients awaiting revision. 55% of ASR hips showed higher metal ions (>7 ppb) whereas only 15% of non-ASR hips had higher ion levels. Patients with reduced postoperative hip offset by more than 5 mm had significantly higher mean metal ion levels compared to the the rest of the hips (31.8 ppb vs. 7.4 ppb, p=0.002). On subgroup analysis this effect was present in non-ASR hips (18.7 ppb vs. 4.7 ppb, p=0.025) but was not significant in ASR hips (29.6 ppb vs. 16.3 ppb, p=0.347).

Our study demonstrated significantly higher serum metal ion levels in patients who lost more than 5 mm hip offset after arthroplasty. Reduced soft tissue tension leading to microseparation of the articulation and edge loading is a theoretical explanation for this effect. This may be relevant in other hard bearings such as ceramic-on-ceramic as well.


S Lakkol K Boddu C Buckle V Kavarthapu P Li

The aim of this retrospective study was to evaluate the failure rate among different fixation devices for undisplaced fracture neck of femur. All 52 patients with Garden I and II hip fractures who underwent surgery in a teaching hospital in London from January 2007 to June 2012 were included. Electronic patient records were accessed to collect the patient data.

There were 52% females and the mean age of patients was 70 years. Thirty patients had cannulated screws, 18 – dynamic hip screw (DHS) with de-rotation screw and 4 had DHS alone. Initial results showed that 36% patients had re-operation. 7(77%) had total hip replacement and 1(11%) had metal work removal. The reason for revision was failure of fixation in 8 (88%) and avascular necrosis in 1 (11%). There was significantly higher failure rate in the DHS with derotation screw group (50%) compared to the cannulated screw group (35%) and the DHS alone group (0%). Average time to planned revision was 11.1 months.

Traditionally undisplaced intra capsular hip fractures are treated by in-situ fixation using different devices. Biomechanically DHS with de-rotation screw achieves better rotational and axial stability compared to other fixation devices. However, our study showed a higher failure rate in this group. Inability to achieve a perfectly parallel screw position seems to be a significant factor responsible for high failure. Higher failure rates with fixation may boost the role of replacement arthroplasty as one off surgical treatment in elderly patients.


S. Bleibleh R. Singh N. Kanakaris P.V. Giannoudis

The management of upper limb nonunions can be challenging and often with unpredictable outcomes. In the study we present the results of treatment of upper limb nonunions treated in our institution with BMP-7 biological enhancement.

Between 2004 and 2011 all consecutive patients who met the inclusion criteria were followed up prospectively. Union was assessed with regular radiological assessment. At the final follow up clinical assessment included the disabilities of the Arm, Shoulder and Hand (DASH) score, range of movement and patient satisfaction. The mean follow up was 12 months (12–36).

In total 42 patients met the inclusion criteria with a mean age of 47. Anatomical distribution of the nonunion sites included 19 cases of mid/proximal radius/ulna, 14 humerus, 6 distal radius and 3 clavicles. 5 patients had septic nonunion, 35 had atrophic nonunion, 11 had previous open fractures, and 10 had bone loss (range 1–3 cm). The mean number of operations performed and the mean time from injury to BMP application was 1.5 and 26 months, respectively. 40 patients had both clinical and radiological union whereas 2 had partial radiological union but a pain free range of motion. BMP was applied in isolation in 1 case and 41 cases the application was combined with autologous bone grafting. The range of movement of the affected limb, DASH score and patient satisfaction were optimum at the final follow up.

This study supports the use of BMP-7 as a bone stimulating adjunct for the treatment of complex and challenging upper limb nonunions.


H.S. Khan S. Goudie K. Deep

Introduction:

Restoration of normal hip biomechanics is vital for success of total hip arthroplasty (THA). This requires accurate placement of implants and restoration of limb length and offset. The purpose of this study was to assess the accuracy of computer navigation system in predicting cup placement and restoring limb length and offset.

Material and Methods:

An analysis of 259 consecutive patients who had THA performed with imageless computer navigation system was carried out. Acetabular cup abduction and anteversion, medialisation or lateralisation of offset and limb length change were compared between navigation measurements and follow-up radiographs. Sensitivity, specificity, accuracy and PPV were calculated to assess navigation for cup orientation and student t-test used for evaluation of offset and limb length change.


A Parthasarathy L Johnston A Jariwala

Numbness around the surgical scar can be a source of discomfort or dissatisfaction in a proportion of patients undergoing Total Knee Arthroplasty (TKA). Literature reports wide variation in its prevalence and the consequence of numbness on the outcome of TKA is not clear. We aimed to investigate the prevalence of numbness, along with contributing factors, and assess its effect on the functional outcome of TKA.

A total of 258 patients were included in this prospective cross sectional patient reported outcome measure study. Demographic details, type and length of incision, and pre-operative and one year post-operative Knee Society Scores (KSS) were recorded and compared. A Dundee knee numbness classification was developed for the assessment of numbness. The prevalence of numbness at one year was 53%, with a female preponderance. Patients above 70 years were less affected. The BMI, laterality and incision length did not affect its occurrence. Discomfort due to numbness was recorded in 8.7% of patients, 75% of which were females. The incision length and numb area positively correlated. The KSS did not correlate with the presence or area of numbness.

Our findings indicate a high prevalence of numbness after TKA. Nevertheless, numbness does not affect the functional outcome.


S Pujar M Kiran A Jariwala C Wigderowitz

Background

The optimal treatment for symptomatic elbow osteoarthritis remains debatable especially in patients still involved in heavy manual work. The Outerbridge-Kashiwagi (OK) procedure has been used when simple measures fail. The aim of this study is to analyse the results of the OK procedure in patients with symptomatic osteoarthritis.

Methods

Twenty-two patients were included in the study. The male:female ratio was 18:4. The mean age was 60 years with mean follow-up of 38 months (24–60 months). 17 were manual workers, 3 involved in sports activities and 2 non-manual workers. All patients were assessed using Mayo Elbow Performance Index Score system. Preoperative radiological assessment showed osteophytes around olecranon and coronoid process and joint space narrowing in radio-humeral articulationin all cases.


A. Dutta J. Edwin

Tibial and femoral loosening are major causes for implant failure in total knee arthroplasty. Jefferey (1991) reported a significantly lower rate of loosening when varus or valgus was within 3 degrees of mechanical axis in an eight year follow up. Coulle (Dec1999) reported 48% unacceptable alignment in non-navigated knees and Reed (Aug 2002) reported 35% alignments deviating more than 3 degrees from mechanical axis when navigation was not used.

We report our series of 286 navigated knee replacements using the Aesculap Search system (21 cases) and the Aesculap e-motion versions 4.2, 4.3 and 4.4 (265 cases) between April 2003 and December 2012 by the author (A.D) and analysed the correction achieved against the zero mechanical axis. Postoperative measurement of the angles on long length films was done in 23 cases. This matched with the intraoperative corrections achieved as studied using per-operative computer data stored for every case. We continued to use the data stored in the AESCULAP System to correlate the findings in the rest of the cases. The average mechanical axis achieved was 1.3 degrees. All cases had mechanical axes within 3 degrees.

We were thus able to achieve a high level of correction of the mechanical axes predictable to achieve better clinical outcomes.


P. Mohanlal S. Jain

A prospective study was done to assess the outcome of MPFL reconstruction for patellar instability using quadriceps graft. MPFL reconstruction was done using superficial strip of quadriceps by an anteromedial incision and attached close to medial epicondyle of femur. There were 15 knees in thirteen patients with a mean age of 23.4 years. All patients had MPFL reconstruction and 5 had tibial tuberosity transfers. With a mean follow-up of 39.4 (12–57) months, the mean pre-op Kujala scores improved from 47.8 to 87.2. The mean Lysholm scores improved from 54.2 to 86.8. None of the patients had patella re-dislocations. MPFL reconstruction with quadriceps graft appears to be effective producing good results in patients with patellar instability.


A Gavaskar

The study aims to compare the short-term results of cemented and cementless total hip arthroplasty {THA} in active patients > 80 years of age with femoral neck fractures. Sixty two consecutive patients underwent THA during the study period {cemented -31 and cementless -31}. The mean age was 84 years {81–94 years}. Patients in both groups were comparable in their preoperative variables. Functional and radiological assessments were carried out using validated outcome measures. Complications were recorded. 51 patients were available for final analysis after accounting for deaths and cases lost in follow up. Of the 51 patients, 25 {49%} regained their pre-injury mobility status and 36 {70%} were community ambulant. Cementless THA was associated with significantly less surgical time, blood loss, transfusion rates and hospital stay. The overall mortality rates, complications, functional and radiological results were similar in both groups though the number of deaths in the perioperative period were significantly high in patients undergoing cemented THA. Satisfactory improvement in function with low reoperation rates can be achieved irrespective of the technique used. Complication rates are higher when compared to younger patients undergoing the procedure. Risks and benefits should be carefully assessed and explained before subjecting these patients to THA.


S Dhatt

The purpose of this study is to find the clinical outcome of decompression of Cauda Equina presenting late in the course of disease. There were 33 males and 17 females with average age of 48 years, ranging from 25 to 85 years. All patients presented to us with a fully developed Cauda Equina syndrome (CES). All of them presented late with mean delay of 12.2 days. Time interval between bladder and bowel dysfunction and admission to hospital varied from 1 to 35 days. The average follow-up was 34.5 months, ranging from 12 to 60 months. There was no statistically significant difference in time of delay in surgery between the recovered and non-recovered group as tested by Student's t test. But there was a statistically significant positive correlation between duration taken for total recovery and delay in surgery. Anal wink as a predictor of bladder and bowel recovery also showed statistical significance, as patients with an absence had a poorer prognosis for bladder recovery. The result of surgery in CES is not as dramatic and fast as seen after routine disc surgery. Some improvement can be expected with decompression even in those patients presenting late and results are not universally poor as previously thought. The treating physicians of such patients should be aware that the recovery in this group of patients can take an exceptionally long time and hence should involve in constant reassurance and rehabilitation of the patient. Presence of anal wink is a very good predictor of bladder and bowel recovery


S Haque M Umar A Khan N Osei

The aim of our study was to assess the outcome of caudal epidural injection for patients with low back pain in relation to fatty infiltration of spinal muscle. This is a prospective study. The spinal muscles were graded on sagittal section T1 MRI at the lower border of lumber 4 vertebra from 3 to 12 depending on the severity of fatty infiltration. The outcome of the intervention was assessed by improvement in pre and post intervention oswestry disability index score as well as visual analog pain score. Patients with significant fatty changes don't respond well to the caudal epidural injection.


A Arya O Berber A Tavakkolizedah J Compson J Sinha

29 cases of complex elbow injuries were reviewed at a mean period of 15 months. Outcome measures included MEPS and DASH score. Patients who had defined early surgery were significantly better than those in whom surgery was delayed. We concluded that Management of complex elbow injuries can be improved by early definitive surgery. The magnitude and type of soft tissue injuries should be identified. MRI scans should be liberally used for this purpose. We believe that early, adequate and appropriate management of soft tissue injuries including use of articulated external fixator for early mobilisation improves the outcome of complex elbow injuries.


K. K. Naikoti A. Sylvan H. WynnJones N. Shah A. Clayson

The radiological evidence of implant failure following plate fixation of traumatic pubic symphysis diastasis can be up to 75%. We report the complications following symphyseal double orthogonal plating in patients with pubic symphysis diastasis over a period of 2.5 years. Patient records and radiographs of 38 consecutive patients were reviewed with mean follow up of 12.5 months. 5 patients (13%) had radiological evidence of implant failure with one patient (2.6%) requiring revision surgery. There was no evidence of wound complications. We conclude that our lower rate of revision surgery and metal work failure is attributed to double orthogonal plating.


A. Lakdawala A. Thomas V. Mandalia

The resection of distal femur and proximal tibia during TKR is 90° to mechanical axis but in a normal knee, the joint line is 3°varus. We measured various angles on long-leg alignment radiographs. The mean age was 58.7 years. The mean HKA axis was 4.3°± 0.5°, mPTA was 3.8°±0.5°, mLDFA was 3.6±0.5° and aLDFA was 8.6°±0.5°. The mean HKA & MPTA were approximately 4°varus, mLDFA 4° valgus & aLDFA 8°valgus. The alignment of the knee to its mechanical axis during TKR is therefore not anatomic. This raises a question whether the knee should be aligned to its kinematic axis instead of mechanical axis.


S. Garg I. Elzein T. Lawrence E Charles V Kumar P. Manning L. Neumann W.A. Wallace

Background

Nonsurgical treatment of Acromioclavicular joint dislocations is well established. Most patients treated conservatively do well, however, some of them develop persistent symptoms. We have used two different surgical reconstruction techniques for Chronic ACJ dislocation stabilization. The study evaluates the effectiveness of a braided polyester prosthetic ligament and modified Weaver-Dunn reconstruction methods.

Methods

55 patients (mean age 42) with Chronic Acromioclavicular joint dislocation were included in this study. They were treated either by a modified Weaver-Dunn method or a braided polyester prosthetic ligament. Patients were assessed using Oxford shoulder score preoperatively and a minimum of 12 months postoperatively.


K. Karuppaiah M. Khan J. Sinha A. Arya

Contoured locking plates are commonly used to fix the proximal humerus fractures. Their long-term results are unknown. We present long-term radiological and functional outcome of three and four part fractures of the proximal humerus treated with PHILOS plate.

We prospectively analysed 53 consecutive three and four part proximal humerus fractures treated with PHILOS plate between 2002 and 2007. Patients were assessed using Oxford Shoulder Score and DASH score. 44 fractures (21 three part and 23 four part) were available at the final follow up.

At a mean follow-up of 8.5 years (6.4 years–10.8 years) the average Oxford Shoulder Score was 43.9 (range 23–48) and the average DASH score was 7.7 (range 0–36.7). 30% of patients required re-operation (five for hemiarthroplasty, three for impingement syndrome, five for removal of implant). Avascular necrosis (AVN) developed in 10 patients, of which only three required hemiarthroplasty. All except one patient were satisfied with the result of their operation.

Our study supports the use of locking plates for the treatment of three and four part proximal humeral fractures. In spite of some patients requiring secondary surgical intervention in the first few years, the function of the shoulder continues to improve and in the long term patients were satisfied with the outcome. An important finding of our study is that the post-traumatic AVN of humeral head does not necessarily need major surgical intervention. We believe that the possibility of avascular necrosis should not be a major determinant in the choice of surgical treatment of proximal humeral fractures.


H.L.M. Williams T.R. Madhusudhan A. Sinha

We retrospectively analysed a single surgeon series of 22 TER in 21 patients over a 12 year period. The mean age and follow up was 59.1 years and 64 months respectively. DASH scores assessed pre and post op confirmed a significant improvement. Complications included infection, intra-operative fracture, peri-prosthetic fracture and aseptic loosening. 6 revisions were performed for various reasons.4 patients had died due to unrelated causes. The 10 year survival rate with symptomatic aseptic loosening as the end point was 93%. 5 patients had radiological loosening but were clinically asymptomatic. TER is a rewarding procedure in with advanced RA.