Advertisement for orthosearch.org.uk
Orthopaedic Proceedings Logo

Receive monthly Table of Contents alerts from Orthopaedic Proceedings

Comprehensive article alerts can be set up and managed through your account settings

View my account settings

Visit Orthopaedic Proceedings at:

Loading...

Loading...

Full Access

General Orthopaedics

DOUBLE PLATING OF TRAUMATIC SYMPHYSIS PUBIS DIASTASIS: RESULTS AND COMPLICATIONS

The Indian Orthopaedic Society (UK) (IOSUK)



Abstract

The radiological evidence of implant failure following plate fixation of traumatic pubic symphysis diastasis can be up to 75%. We report the complications following symphyseal double orthogonal plating in patients with pubic symphysis diastasis over a period of 2.5 years. Patient records and radiographs of 38 consecutive patients were reviewed with mean follow up of 12.5 months. 5 patients (13%) had radiological evidence of implant failure with one patient (2.6%) requiring revision surgery. There was no evidence of wound complications. We conclude that our lower rate of revision surgery and metal work failure is attributed to double orthogonal plating.