We evaluated the impact of stereo-visualisation of
We created virtual
This randomised study compared outcomes in patients with displaced fractures of the clavicle treated by open reduction and fixation by a reconstruction plate which was placed either superiorly or three-dimensionally. Between 2003 and 2006, 133 consecutive patients with a mean age of 44.2 years (18 to 60) with displaced midshaft fractures of the clavicle were allocated randomly to a
Existing classifications of fractures of the head of the humerus are inadequate in terms of interobserver reliability and the predictability of the clinical outcome. From a combined study of 73 fracture specimens in museums and 84 CT-three-dimensional reconstructions in patients, we have devised a classification which appears to be more useful clinically. Common patterns of fracture and a plausible mechanism of injury were observed. In 3-D most proximal humeral fractures can be organised into five basic types. These correspond in some degree to the Codman/Neer classification, but differ significantly in regard to the more complex patterns of fracture. We observed a logical progression from simple to complex fractures. An interobserver reliability study was carried out which indicated the improved usefulness of this new 3-D concept in providing a common language among clinicians for classifying these injuries. When surgery is indicated, the 3-D concept is also invaluable in guiding the restitution of anatomy through either open or percutaneous means.
We evaluated the effect of low-intensity pulsed ultrasound stimulation (LIPUS) on the remodelling of callus in a rabbit gap-healing model by bone morphometric analyses using
We describe the routine imaging practices of
Level 1 trauma centres for patients with severe pelvic ring fractures, and
the interobserver reliability of the classification systems of these
fractures using plain radiographs and
Our aim was to determine the effect of the initial pattern of fracture and the displacement of fragments on the outcome of proximal humeral fractures treated conservatively. We followed 93 consecutive patients prospectively for one year. Final movement and strength were compared with those of the contralateral side. The final American Shoulder and Elbow Society score and the Disabilities of Arm, Shoulder and Hand and Short-Form 36 questionnaires were compared with those provided by the patient on the day of the injury. Radiographs and CT scans with
Plain radiographs show only two dimensions of a
This study compared the quality of reduction
and complication rate when using a standard ilioinguinal approach and
the new pararectus approach when treating acetabular fractures surgically.
All acetabular fractures that underwent fixation using either approach
between February 2005 and September 2014 were retrospectively reviewed
and the demographics of the patients, the surgical details and complications
were recorded. A total of 100 patients (69 men, 31 women; mean age 57 years,
18 to 93) who were consecutively treated were included for analysis.
The quality of reduction was assessed using standardised measurement
of the gaps and steps in the articular surface on pre- and post-operative
CT-scans. There were no significant differences in the demographics of
the patients, the surgical details or the complications between
the two approaches. A significantly better reduction of the gap,
however, was achieved with the pararectus approach (axial: p = 0.025,
coronal: p = 0.013, sagittal: p = 0.001). These data suggest that the pararectus approach is at least equal
to, or in the case of reduction of the articular gap, superior to
the ilioinguinal approach. This approach allows direct buttressing of the dome of the acetabulum
and the quadrilateral plate, which is particularly favourable in
geriatric fracture patterns. Cite this article:
This study aimed to determine the long-term functional,
clinical and radiological outcomes in patients with Schatzker IV
to VI fractures of the tibial plateau treated with an Ilizarov frame.
Clinical, functional and radiological assessment was carried out
at a minimum of one year post-operatively. A cohort of 105 patients
(62 men, 43 women) with a mean age of 49 years (15 to 87) and a
mean follow-up of 7.8 years (1 to 19) were reviewed. There were
18 type IV, 10 type V and 77 type VI fractures. All fractures united
with a mean time to union of 20.1 weeks (10.6 to 42.3). No patient
developed a deep infection. The median range of movement (ROM) of
the knee was 110o and the median Iowa score was 85. Our study demonstrates good long-term functional outcome with
no deep infection; spanning the knee had no detrimental effect on
the ROM or functional outcome. High-energy fractures of the tibial plateau may be treated effectively
with a fine wire Ilizarov fixator. Cite this article:
This study identifies early risk factors for symptomatic nonunion
of displaced midshaft fractures of the clavicle that aid identification
of an at risk group who may benefit from surgery. We performed a retrospective study of 88 patients aged between
16 and 60 years that were managed non-operatively. Aims
Methods
Compression and absolute stability are important in the management of intra-articular fractures. We compared tension band wiring with plate fixation for the treatment of fractures of the olecranon by measuring compression within the fracture. Identical transverse fractures were created in models of the ulna. Tension band wires were applied to ten fractures and ten were fixed with Acumed plates. Compression was measured using a Tekscan force transducer within the fracture gap. Dynamic testing was carried out by reproducing cyclical contraction of the triceps of 20 N and of the brachialis of 10 N. Both methods were tested on each sample. Paired The mean compression for plating was 819 N ( During simulated movements, the mean compression was reduced in both groups, with tension band wiring at −14 N ( Pre-contoured plates provide significantly greater compression than tension bands in the treatment of transverse fractures of the olecranon, both over the whole fracture and specifically at the articular side of the fracture. In tension band wiring the overall compression was reduced and articular compression remained negligible during simulated contraction of the triceps, challenging the tension band principle.
The aim of this study was to quantify the stability
of fracture-implant complex in fractures after fixation. A total
of 15 patients with an undisplaced fracture of the femoral neck,
treated with either a dynamic hip screw or three cannulated hip
screws, and 16 patients with an AO31-A2 trochanteric fracture treated
with a dynamic hip screw or a Gamma Nail, were included. Radiostereometric
analysis was used at six weeks, four months and 12 months post-operatively
to evaluate shortening and rotation. Migration could be assessed in ten patients with a fracture of
the femoral neck and seven with a trochanteric fracture. By four
months post-operatively, a mean shortening of 5.4 mm (-0.04 to 16.1)
had occurred in the fracture of the femoral neck group and 5.0 mm
(-0.13 to 12.9) in the trochanteric fracture group. A wide range
of rotation occurred in both types of fracture. Right-sided trochanteric
fractures seem more rotationally stable than left-sided fractures. This prospective study shows that migration at the fracture site
occurs continuously during the first four post-operative months,
after which stabilisation occurs. This information may allow the
early recognition of patients at risk of failure of fixation. Cite this article:
We treated 47 patients with a mean age of 57 years (22 to 88) who had a proximal humeral fracture in which there was a severe varus deformity, using a standard operative protocol of anatomical reduction, fixation with a locking plate and supplementation by structural allografts in unstable fractures. The functional and radiological outcomes were reviewed. At two years after operation the median Constant score was 86 points and the median Disabilities of the Arm, Shoulder and Hand score 17 points. Seven of the patients underwent further surgery, two for failure of fixation, three for dysfunction of the rotator cuff, and two for shoulder stiffness. The two cases of failure of fixation were attributable to violation of the operative protocol. In the 46 patients who retained their humeral head, all the fractures healed within the first year, with no sign of collapse or narrowing of the joint space. Longer follow-up will be required to confirm whether these initially satisfactory results are maintained.
A new anterior intrapelvic approach for the surgical
management of displaced acetabular fractures involving predominantly
the anterior column and the quadrilateral plate is described. In
order to establish five ‘windows’ for instrumentation, the extraperitoneal
space is entered along the lateral border of the rectus abdominis
muscle. This is the so-called ‘Pararectus’ approach. The feasibility
of safe dissection and optimal instrumentation of the pelvis was
assessed in five cadavers (ten hemipelves) before implementation
in a series of 20 patients with a mean age of 59 years (17 to 90),
of whom 17 were male. The clinical evaluation was undertaken between
December 2009 and December 2010. The quality of reduction was assessed
with post-operative CT scans and the occurrence of intra-operative
complications was noted. In the treatment of acetabular fractures predominantly involving
the anterior column and the quadrilateral plate, the Pararectus
approach allowed anatomical restoration with minimal morbidity related
to the surgical access.
Antegrade nailing of proximal humeral fractures
using a straight nail can damage the bony insertion of the supraspinatus
tendon and may lead to varus failure of the construct. In order
to establish the ideal anatomical landmarks for insertion of the
nail and their clinical relevance we analysed CT scans of bilateral
proximal humeri in 200 patients (mean age 45.1 years ( We therefore emphasise the need for ‘fastidious’ pre-operative
planning to minimise this risk. Cite this article:
The augmentation of fixation with bone cement
is increasingly being used in the treatment of severe osteoporotic fractures.
We investigated the influence of bone quality on the mechanics of
augmentation of plate fixation in a distal femoral fracture model
(AO 33 A3 type). Eight osteoporotic and eight non-osteoporotic femoral
models were randomly assigned to either an augmented or a non-augmented
group. Fixation was performed using a locking compression plate.
In the augmented group additionally 1 ml of bone cement was injected
into the screw hole before insertion of the screw. Biomechanical
testing was performed in axial sinusoidal loading. Augmentation significantly
reduced the cut-out distance in the osteoporotic models by about
67% (non-augmented mean 0.30 mm ( Cite this article:
Several bisphosphonates are now available for the treatment of osteoporosis. Porous hydroxyapatite/collagen (HA/Col) composite is an osteoconductive bone substitute which is resorbed by osteoclasts. The effects of the bisphosphonate alendronate on the formation of bone in porous HA/Col and its resorption by osteoclasts were evaluated using a rabbit model. Porous HA/Col cylinders measuring 6 mm in diameter and 8 mm in length, with a pore size of 100 μm to 500 μm and 95% porosity, were inserted into a defect produced in the lateral femoral condyles of 72 rabbits. The rabbits were divided into four groups based on the protocol of alendronate administration: the control group did not receive any alendronate, the pre group had alendronate treatment for three weeks prior to the implantation of the HA/Col, the post group had alendronate treatment following implantation until euthanasia, and the pre+post group had continuous alendronate treatment from three weeks prior to surgery until euthanasia. All rabbits were injected intravenously with either saline or alendronate (7.5 μg/kg) once a week. Each group had 18 rabbits, six in each group being killed at three, six and 12 weeks post-operatively. Alendronate administration suppressed the resorption of the implants. Additionally, the mineral densities of newly formed bone in the alendronate-treated groups were lower than those in the control group at 12 weeks post-operatively. Interestingly, the number of osteoclasts attached to the implant correlated with the extent of bone formation at three weeks. In conclusion, the systemic administration of alendronate in our rabbit model at a dose-for-weight equivalent to the clinical dose used in the treatment of osteoporosis in Japan affected the mineral density and remodelling of bone tissue in implanted porous HA/Col composites.
We investigated a new intramedullary locking
nail that allows the distal interlocking screws to be locked to
the nail. We compared fixation using this new implant with fixation
using either a conventional nail or a locking plate in a laboratory
simulation of an osteoporotic fracture of the distal femur. A total
of 15 human cadaver femora were used to simulate an AO 33-A3 fracture
pattern. Paired specimens compared fixation using either a locking
or non-locking retrograde nail, and using either a locking retrograde
nail or a locking plate. The constructs underwent cyclical loading
to simulate single-leg stance up to 125 000 cycles. Axial and torsional
stiffness and displacement, cycles to failure and modes of failure
were recorded for each specimen. When compared with locking plate
constructs, locking nail constructs had significantly longer mean
fatigue life (75 800 cycles ( The new locking retrograde femoral nail showed better stiffness
and fatigue life than locking plates, and superior fatigue life
to non-locking nails, which may be advantageous in elderly patients. Cite this article:
In Neer type II (Robinson type 3B) fractures
of the distal clavicle the medial fragment is detached from the coracoclavicular
ligaments and displaced upwards, whereas the lateral fragment, which
is usually small, maintains its position. Several fixation techniques
have been suggested to treat this fracture. The aim of this study
was to assess the outcome of patients with type II distal clavicle
fractures treated with coracoclavicular suture fixation using three
loops of Ethibond. This prospective study included 14 patients with
Neer type II fractures treated with open reduction and coracoclavicular
fixation. Ethibond sutures were passed under the coracoid and around
the clavicle (UCAC loop) without making any drill holes in the proximal
or distal fragments. There were 11 men and three women with a mean
age of 34.57 years (29 to 41). Patients were followed for a mean
of 24.64 months (14 to 31) and evaluated radiologically and clinically
using the Constant score. Fracture union was obtained in 13 patients at
a mean of 18.23 weeks (13 to 23) and the mean Constant score was
96.07 (91 to 100). One patient developed an asymptomatic fibrous
nonunion at one year. This study suggests that open reduction and
internal fixation of unstable distal clavicle fractures using UCAC
loops can provide rigid fixation and lead to bony union. This technique avoids
using metal hardware, preserves the acromioclavicular joint and
provides adequate stability with excellent results. Cite this article:
Neurogenic heterotopic ossification (NHO) is
a disorder of aberrant bone formation affecting one in five patients sustaining
a spinal cord injury or traumatic brain injury. Ectopic bone forms
around joints in characteristic patterns, causing pain and limiting
movement especially around the hip and elbow. Clinical sequelae
of neurogenic heterotopic ossification include urinary tract infection,
pressure injuries, pneumonia and poor hygiene, making early diagnosis
and treatment clinically compelling. However, diagnosis remains
difficult with more investigation needed. Our pathophysiological
understanding stems from mechanisms of basic bone formation enhanced
by evidence of systemic influences from circulating humor factors
and perhaps neurological ones. This increasing understanding guides
our implementation of current prophylaxis and treatment including
the use of non-steroidal anti-inflammatory drugs, bisphosphonates,
radiation therapy and surgery and, importantly, should direct future, more
effective ones.
Osteochondral injuries, if not treated adequately, often lead
to severe osteoarthritis. Possible treatment options include refixation
of the fragment or replacement therapies such as Pridie drilling,
microfracture or osteochondral grafts, all of which have certain
disadvantages. Only refixation of the fragment can produce a smooth
and resilient joint surface. The aim of this study was the evaluation
of an ultrasound-activated bioresorbable pin for the refixation of
osteochondral fragments under physiological conditions. In 16 Merino sheep, specific osteochondral fragments of the medial
femoral condyle were produced and refixed with one of conventional
bioresorbable pins, titanium screws or ultrasound-activated pins.
Macro- and microscopic scoring was undertaken after three months. Objectives
Methods
Most fractures of the radial head are stable
undisplaced or minimally displaced partial fractures without an associated
fracture of the elbow or forearm or ligament injury, where stiffness
following non-operative management is the primary concern. Displaced
unstable fractures of the radial head are usually associated with other
fractures or ligament injuries, and restoration of radiocapitellar
contact by reconstruction or prosthetic replacement of the fractured
head is necessary to prevent subluxation or dislocation of the elbow
and forearm. In fractures with three or fewer fragments (two articular
fragments and the neck) and little or no metaphyseal comminution,
open reduction and internal fixation may give good results. However,
fragmented unstable fractures of the radial head are prone to early
failure of fixation and nonunion when fixed. Excision of the radial
head is associated with good long-term results, but in patients
with instability of the elbow or forearm, prosthetic replacement
is preferred. This review considers the characteristics of stable and unstable
fractures of the radial head, as well as discussing the debatable
aspects of management, in light of the current best evidence. Cite this article:
Filling the empty holes in peri-articular locking
plates may improve the fatigue strength of the fixation. The purpose of
this A locking/compression plate was applied to 33 synthetic femurs
and then a 6 cm metaphyseal defect was created (AO Type 33-A3).
The specimens were then divided into three groups: unplugged, plugged
with locking screw only and fully plugged holes. They were then
tested using a stepwise or run-out fatigue protocol, each applying
cyclic physiological multiaxial loads. All specimens in the stepwise group failed at the 770 N load
level. The mean number of cycles to failure for the stepwise specimen
was 25 500 cycles ( In conclusion, filling the empty combination locking/compression
holes in peri-articular distal femur locking plates at the level
of supracondylar comminution does not increase the fatigue life
of the fixation in a comminuted supracondylar femoral fracture model
(AO 33-A3) with a 6 cm gap.
Fractures and nonunions of the proximal humerus are increasingly treated by open reduction and internal fixation. The extended deltopectoral approach remains the most widely used for this purpose. However, it provides only limited exposure of the lateral and posterior aspects of the proximal humerus. We have previously described the alternative extended deltoid-splitting approach. In this paper we outline variations and extensions of this technique that we have developed in the management of further patients with these fractures.
The purpose of this study was to assess the stability of a developmental pelvic reconstruction system which extends the concept of triangular osteosynthesis with fixation anterior to the lumbosacral pivot point. An unstable Tile type-C fracture, associated with a sacral transforaminal fracture, was created in synthetic pelves. The new concept was compared with three other constructs, including bilateral iliosacral screws, a tension band plate and a combined plate with screws. The pubic symphysis was plated in all cases. The pelvic ring was loaded to simulate single-stance posture in a cyclical manner until failure, defined as a displacement of 2 mm or 2°. The screws were the weakest construct, failing with a load of 50 N after 400 cycles, with maximal translation in the craniocaudal axis of 12 mm. A tension band plate resisted greater load but failure occurred at 100 N, with maximal rotational displacement around the mediolateral axis of 2.3°. The combination of a plate and screws led to an improvement in stability at the 100 N load level, but rotational failure still occurred around the mediolateral axis. The pelvic reconstruction system was the most stable construct, with a maximal displacement of 2.1° of rotation around the mediolateral axis at a load of 500 N.
Our aim in this pilot study was to evaluate the fixation of, the bone remodelling around, and the clinical outcome after surgery of a new, uncemented, fully hydroxyapatite-coated, collared and tapered femoral component, designed specifically for elderly patients with a fracture of the femoral neck. We enrolled 50 patients, of at least 70 years of age, with an acute displaced fracture of the femoral neck in this prospective single-series study. They received a total hip replacement using the new component and were followed up regularly for two years. Fixation was evaluated by radiostereometric analysis and bone remodelling by dual-energy x-ray absorptiometry. Hip function and the health-related quality of life were assessed using the Harris hip score and the EuroQol-5D. Up to six weeks post-operatively there was a mean subsidence of 0.2 mm (−2.1 to +0.5) and a retroversion of a mean of 1.2° (−8.2° to +1.5°). No component migrated after three months. The patients had a continuous loss of peri-prosthetic bone which amounted to a mean of 16% (−49% to +10%) at two years. The mean Harris hip score was 82 (51 to 100) after two years. The two-year results from this pilot study indicate that this new, uncemented femoral component can be used for elderly patients with osteoporotic fractures of the femoral neck.
We describe our early operative experience with a new pelvic reduction frame and the standard of reduction of fractures of the pelvic ring which we achieved in the first 35 consecutive patients, with 34 acute fractures and one nonunion. The pre-operative and immediate post-operative radiographs were measured, using two methods, to find the maximum radiological displacement of the fracture and the quality of the reduction according to the criteria of Tornetta and Matta. There were 19 vertical shear fractures and 16 compression injuries. The mean age of the patients was 33.5 years (10 to 59) and mean delay to surgery was 4.6 days (0 to 16) in the 34 acute injuries. The mean operative time in isolated procedures was 103.4 minutes ( The frame was shown to be effective, allowing the surgeon to obtain a satisfactory reduction and fixation of acute displaced disruptions of the pelvic ring.
The surgical treatment of three- and four-part fractures of the proximal humerus in osteoporotic bone is difficult and there is no consensus as to which technique leads to the best outcome in elderly patients. Between 1998 and 2004 we treated 76 patients aged over 70 years with three- or four-part fractures by percutaneous reduction and internal fixation using the Humerusblock. A displacement of the tuberosity of >
5 mm and an angulation of >
30° of the head fragment were the indications for surgery. Of the patients 50 (51 fractures) were available for follow-up after a mean of 33.8 months (5.8 to 81). The absolute, age-related and side-related Constant scores were recorded. Of the 51 fractures, 46 (90.2%) healed primarily. Re-displacement of fragments or migration of Kirschner wires was seen in five cases. Necrosis of the humeral head developed in four patients. In three patients a secondary arthroplasty had to be performed, in two because of re-displacement and in one for necrosis of the head. There was one case of deep infection which required a further operation and one of delayed healing. The mean Constant score of the patients with a three-part fracture was 61.2 points (35 to 87) which was 84.9% of the score for the non-injured arm. In four-part fractures it was 49.5 points (18 to 87) or 68.5% of the score for the non-injured arm. The Humerusblock technique can provide a comfortable and mobile shoulder in elderly patients and is a satisfactory alternative to replacement and traditional techniques of internal fixation.
We have reviewed our experience in managing 11 patients who sustained an indirect sternal fracture in combination with an upper thoracic spinal injury between 2003 and 2006. These fractures have previously been described as ‘associated’ fractures, but since the upper thorax is an anatomical entity composed of the upper thoracic spine, ribs and sternum joined together, we feel that the term ‘fractures of the upper transthoracic cage’ is a better description. These injuries are a challenge because they are unusual and easily overlooked. They require a systematic clinical and radiological examination to identify both lesions. This high-energy trauma gives severe devastating concomitant injuries and CT with contrast and reconstruction is essential after resuscitation to confirm the presence of all the lesions. The injury level occurs principally at T4–T5 and at the manubriosternal joint. These unstable fractures need early posterior stabilisation and fusion or, if treated conservatively, a very close follow-up.
The generally-accepted treatment for large, displaced fractures of the glenoid associated with traumatic anterior dislocation of the shoulder is operative repair. In this study, 14 consecutive patients with large (>
5 mm), displaced (>
2 mm) anteroinferior glenoid rim fractures were treated non-operatively if post-reduction radiographs showed a centred glenohumeral joint. After a mean follow-up of 5.6 years (2.8 to 8.4), the mean Constant score and subjective shoulder value were 98% (90% to 100%) and 97% (90% to 100%), respectively. There were no redislocations or subluxations, and the apprehension test was negative. All fragments healed with an average intra-articular step of 3.0 mm (0.5 to 11). No patient had symptoms of osteoarthritis, which was mild in two shoulders and moderate in one. Traumatic anterior dislocation of the shoulder, associated with a large displaced glenoid rim fracture can be successfully treated non-operatively, providing the glenohumeral joint is concentrically reduced on the anteroposterior radiograph.
The extended lateral L-shaped approach for the treatment of displaced intra-articular fractures of the calcaneum may be complicated by wound infection, haematoma, dehiscence and injury to the sural nerve. In an effort to reduce the risk of problems with wound healing a technique was developed that combined open reduction and fixation of the joint fragments and of the anterior process with percutaneous reduction and screw fixation of the tuberosity. A group of 24 patients with unilateral isolated closed Sanders type II and III fractures was treated using this technique and compared to a similar group of 26 patients managed by the extended approach and lateral plating. The operation was significantly shorter (p <
0.001) in the first group, but more minor secondary procedures and removal of heel screws were necessary. There were no wound complications in this group, whereas four minor complications occurred in the second group. The accuracy and maintenance of reduction, and ultimate function were equivalent.
A minimally-invasive procedure using percutaneous reduction and external fixation can be carried out for Sanders’ type II, III and IV fractures of the os calcis. We have treated 54 consecutive closed displaced fractures of the calcaneum involving the articular surface in 52 patients with the Orthofix Calcaneal Mini-Fixator. Patients were followed up for a mean of 49 months (27 to 94) and assessed clinically with the Maryland Foot Score and radiologically with radiographs and CT scans, evaluated according to the Score Analysis of Verona. The clinical results at follow-up were excellent or good in 49 cases (90.7%), fair in two (3.7%) and poor in three (5.6%). The mean pre-operative Böhler’s angle was 6.98° (5.95° to 19.86°), whereas after surgery the mean value was 21.94° (12.58° to 31.30°) (p <
0.01). Excellent results on CT scanning were demonstrated in 24 cases (44.4%), good in 25 (46.3%), fair in three (5.6%) and poor in two (3.7%). Transient local osteoporosis was observed in ten patients (18.5%), superficial pin track infection in three (5.6%), and three patients (5.6%) showed thalamic displacement following unadvised early weight-bearing. The clinical results appear to be comparable with those obtainable with open reduction and internal fixation, with the advantages of reduced risk using a minimally-invasive technique.
Crescent fracture dislocations are a well-recognised subset of pelvic ring injuries which result from a lateral compression force. They are characterised by disruption of the sacroiliac joint and extend proximally as a fracture of the posterior iliac wing. We describe a classification with three distinct types. Type I is characterised by a large crescent fragment and the dislocation comprises no more than one-third of the sacroiliac joint, which is typically inferior. Type II fractures are associated with an intermediate-size crescent fragment and the dislocation comprises between one- and two-thirds of the joint. Type III fractures are associated with a small crescent fragment where the dislocation comprises most, but not all of the joint. The principal goals of surgical intervention are the accurate and stable reduction of the sacroiliac joint. This classification proves useful in the selection of both the surgical approach and the reduction technique. A total of 16 patients were managed according to this classification and achieved good functional results approximately two years from the time of the index injury. Confounding factors compromise the summary short-form-36 and musculoskeletal functional assessment instrument scores, which is a well-recognised phenomenon when reporting the outcome of high-energy trauma.
There remains uncertainty about the most effective surgical approach in the treatment of complex fractures of the acetabulum. We have reviewed the experience of a single surgeon using the extended iliofemoral approach, as described by Letournel. A review of the database of such fractures identified 106 patients operated on using this approach with a minimum follow-up of two years. All data were collected prospectively. The fractures involved both columns in 64 (60%). Operation was undertaken in less than 21 days after injury in 71 patients (67%) and in 35 (33%) the procedure was carried out later than this. The reduction of the fracture was measured on plain radiographs taken after operation and defined as anatomical (0 to 1 mm of displacement); imperfect (2 to 3 mm) or poor (>
3 mm). The functional outcome was measured by the modified Merle d’Aubigné and Postel score. The mean follow-up was for 6.3 years (2 to 17). All patients achieved union of the fractures. The reduction was graded as anatomical in 76 (72%) of the patients, imperfect in 23 (22%), and poor in six (6%). The mean Merle d’Aubigné and Postel score was 15 (5 to 18) with 68 patients (64%) showing good or excellent and 38 (36%) fair or poor results. Function correlated significantly with the accuracy of the reduction (p <
0.009). Significant heterotopic ossification developed in 32 patients (30%) and was associated with a worse mean Merle d’Aubigné and Postel score of 13.7. The extended iliofemoral approach can be performed safely in selected complex acetabular fractures with an acceptable clinical outcome and rate of complications. Effective prophylaxis against heterotopic ossification should be strongly considered.