Advertisement for orthosearch.org.uk
Results 1 - 100 of 115
Results per page:
The Journal of Bone & Joint Surgery British Volume
Vol. 84-B, Issue 5 | Pages 678 - 679
1 Jul 2002
Crowther MA.A Bannister GC Huma H Rooker GD

We undertook a prospective, randomised study to compare the analgesic effect of injection of steroid and of extracorporeal shock-wave therapy (ESWT) for the treatment of tennis elbow. Group 1 received a single injection of 20 mg of triamcinolone with lignocaine while group 2 received 2000 shock waves in three sessions at weekly intervals. After six weeks there was a significant difference between the groups with the mean pain score for the injection group falling from 66 to 21 compared with a decrease from 61 to 35 in the shock-wave group (p = 0.05). After three months, 84% of patients in group 1 were considered to have had successful treatment compared with 60% in group 2. In the medium term local injection of steroid is more successful and 100 times less expensive than ESWT in the treatment of tennis elbow


Bone & Joint Research
Vol. 10, Issue 2 | Pages 113 - 121
1 Feb 2021
Nicholson JA Oliver WM MacGillivray TJ Robinson CM Simpson AHRW

Aims. To evaluate if union of clavicle fractures can be predicted at six weeks post-injury by the presence of bridging callus on ultrasound. Methods. Adult patients managed nonoperatively with a displaced mid-shaft clavicle were recruited prospectively. Ultrasound evaluation of the fracture was undertaken to determine if sonographic bridging callus was present. Clinical risk factors at six weeks were used to stratify patients at high risk of nonunion with a combination of Quick Disabilities of the Arm, Shoulder and Hand questionnaire (QuickDASH) ≥ 40, fracture movement on examination, or absence of callus on radiograph. Results. A total of 112 patients completed follow-up at six months with a nonunion incidence of 16.7% (n = 18/112). Sonographic bridging callus was detected in 62.5% (n = 70/112) of the cohort at six weeks post-injury. If present, union occurred in 98.6% of the fractures (n = 69/70). If absent, nonunion developed in 40.5% of cases (n = 17/42). The sensitivity to predict union with sonographic bridging callus at six weeks was 73.4% and the specificity was 94.4%. Regression analysis found that failure to detect sonographic bridging callus at six weeks was associated with older age, female sex, simple fracture pattern, smoking, and greater fracture displacement (Nagelkerke R. 2. = 0.48). Of the cohort, 30.4% (n = 34/112) had absent sonographic bridging callus in addition to one or more of the clinical risk factors at six weeks that predispose to nonunion. If one was present the nonunion rate was 35%, 60% with two, and 100% when combined with all three. Conclusion. Ultrasound combined with clinical risk factors can accurately predict fracture healing at six weeks following a displaced midshaft clavicle fracture. Cite this article: Bone Joint Res 2021;10(2):113–121


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 6 | Pages 819 - 823
1 Jun 2005
Boehm TD Werner A Radtke S Mueller T Kirschner S Gohlke F

In a prospective, randomised study on the repair of tears of the rotator cuff we compared the clinical results of two suture techniques for which different suture materials were used. We prospectively randomised 100 patients with tears of the rotator cuff into two groups. Group 1 had transosseous repair with No. 3 Ethibond using modified Mason-Allen sutures and group 2 had transosseous repair with 1.0 mm polydioxanone cord using modified Kessler sutures. After 24 to 30 months the patients were evaluated clinically using the Constant score and by ultrasonography. Of the 100 patients, 92 completed the study. No significant statistical difference was seen between the two groups: Constant score, 91% vs 92%; rate of further tear, 18% vs 22%; and revision, 4% vs 4%. In cases of further tear the outcome in group 2 did not differ from that for the intact repairs (91% vs 91%), but in group 1 it was significantly worse (94% vs 77%, p = 0.005). Overall, seven patients had complications which required revision surgery, in four for pain (two in each group) and in three for infection (two in group 1 and one in group 2)


Bone & Joint Research
Vol. 8, Issue 3 | Pages 118 - 125
1 Mar 2019
Doi N Izaki T Miyake S Shibata T Ishimatsu T Shibata Y Yamamoto T

Objectives

Indocyanine green (ICG) fluorescence angiography is an emerging technique that can provide detailed anatomical information during surgery. The purpose of this study is to determine whether ICG fluorescence angiography can be used to evaluate the blood flow of the rotator cuff tendon in the clinical setting.

Methods

Twenty-six patients were evaluated from October 2016 to December 2017. The participants were categorized into three groups based on their diagnoses: the rotator cuff tear group; normal rotator cuff group; and adhesive capsulitis group. After establishing a posterior standard viewing portal, intravenous administration of ICG at 0.2 mg/kg body weight was performed, and fluorescence images were recorded. The time from injection of the drug to the beginning of enhancement of the observed area was measured. The hypovascular area in the rotator cuff was evaluated, and the ratio of the hypovascular area to the anterolateral area of the rotator cuff tendon was calculated (hypovascular area ratio).


The Bone & Joint Journal
Vol. 95-B, Issue 4 | Pages 523 - 529
1 Apr 2013
Henseler JF Nagels J van der Zwaal P Nelissen RGHH

Surgical repair of posterosuperior rotator cuff tears has a poorer outcome and a higher rate of failure compared with repairs of supraspinatus tears. In this prospective cohort study 28 consecutive patients with an irreparable posterosuperior rotator cuff tear after failed conservative or surgical treatment underwent teres major tendon transfer. Their mean age was 60 years (48 to 71) and the mean follow-up was 25 months (12 to 80). The mean active abduction improved from 79° (0° to 150°) pre-operatively to 105° (20° to 180°) post-operatively (p = 0.011). The mean active external rotation in 90° abduction improved from 25° (0° to 70°) pre-operatively to 55° (0° to 90°) post-operatively (p < 0.001). The mean Constant score improved from 43 (18 to 78) pre-operatively to 65 (30 to 86) post-operatively (p < 0.001). The median post-operative VAS (0 to 100) for pain decreased from 63 (0 to 96) pre-operatively to 5 (0 to 56) post-operatively (p < 0.001). In conclusion, teres major transfer effectively restores function and relieves pain in patients with irreparable posterosuperior rotator cuff tears and leads to an overall clinical improvement in a relatively young and active patient group with limited treatment options. Cite this article: Bone Joint J 2013;95-B:523–9


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 2 | Pages 201 - 205
1 Feb 2009
Hanusch BC Goodchild L Finn P Rangan A

The aim of this study was to determine the functional outcome and rate of re-tears following mini-open repair of symptomatic large and massive tears of the rotator cuff using a two-row technique. The 24 patients included in the study were assessed prospectively before and at a mean of 27 months (18 to 53) after surgery using the Constant and the Oxford Shoulder scores. Ultrasound examination was carried out at follow-up to determine the integrity of the repair. Patient satisfaction was assessed using a simple questionnaire. The mean Constant score improved significantly from 36 before to 68 after operation (p < 0.0001) and the mean Oxford Shoulder score from 39 to 20 (p < 0.0001). Four of the 24 patients (17%) had a re-tear diagnosed by ultrasound. A total of 21 patients (87.5%) were satisfied with the outcome of their surgery. The repair remained intact in 20 patients (83%). However, the small number of re-tears (four patients) in the study did not allow sufficient analysis to show a difference in outcome in relation to the integrity of the repair


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 7 | Pages 918 - 921
1 Jul 2009
Finestone A Milgrom C Radeva-Petrova DR Rath E Barchilon V Beyth S Jaber S Safran O

We undertook a prospective study in 51 male patients aged between 17 and 27 years to ascertain whether immobilisation after primary traumatic anterior dislocation of the shoulder in external rotation was more effective than immobilisation in internal rotation in preventing recurrent dislocation in a physically active population. Of the 51 patients, 24 were randomised to be treated by a traditional brace in internal rotation and 27 were immobilised in external rotation of 15° to 20°. After immobilisation, the patients undertook a standard regime of physiotherapy and were then assessed clinically for evidence of instability. When reviewed at a mean of 33.4 months (24 to 48) ten from the external rotation group (37%) and ten from the internal rotation group (41.7%) had sustained a futher dislocation. There was no statistically significant difference (p = 0.74) between the groups. Our findings show that external rotation bracing may not be as effective as previously reported in preventing recurrent anterior dislocation of the shoulder


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 6 | Pages 764 - 769
1 Jun 2008
Raiss P Aldinger PR Kasten P Rickert M Loew M

Our aim in this prospective study was to evaluate the outcome of total shoulder replacement in the treatment of young and middle-aged active patients with primary glenohumeral osteoarthritis. We reviewed 21 patients (21 shoulders) with a mean age of 55 years (37 to 60). The mean follow-up was seven years (5 to 9). The same anatomical, third-generation, cemented implant had been used in all patients. All the patients were evaluated radiologically and clinically using the Constant and Murley score. No patients required revision. In one a tear of the supraspinatus tendon occurred. Overall, 20 patients (95%) were either very satisfied (n = 18) or satisfied (n = 2) with the outcome. Significant differences (p < 0.0001) were found for all categories of the Constant and Murley score pre- and post-operatively. The mean Constant and Murley score increased from 24.1 points (10 to 45) to 64.5 points (39 to 93), and the relative score from 30.4% (11% to 50%) to 83% (54% to 116%). No clinical or radiological signs of loosening of the implant were seen. For young and middle-aged patients with osteoarthritis, third-generation total shoulder replacement is a viable method of treatment with a low rate of complications and excellent results in the mid-term


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 4 | Pages 504 - 510
1 Apr 2009
Henkus HE de Witte PB Nelissen RGHH Brand R van Arkel ERA

In a prospective randomised study we compared the results of arthroscopic subacromial bursectomy alone with debridement of the subacromial bursa followed by acromioplasty. A total of 57 patients with a mean age of 47 years (31 to 60) suffering from primary subacromial impingement without a rupture of the rotator cuff who had failed previous conservative treatment were entered into the trial. The type of acromion was classified according to Bigliani. Patients were assessed at follow-up using the Constant score, the simple shoulder test and visual analogue scores for pain and functional impairment. One patient was lost to follow-up. At a mean follow-up of 2.5 years (1 to 5) both bursectomy and acromioplasty gave good clinical results. No statistically significant differences were found between the two treatments. The type of acromion and severity of symptoms had a greater influence on the clinical outcome than the type of treatment. As a result, we believe that primary subacromial impingement syndrome is largely an intrinsic degenerative condition rather than an extrinsic mechanical disorder


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 9 | Pages 1197 - 1200
1 Sep 2009
Betts HM Abu-Rajab R Nunn T Brooksbank AJ

We describe the longer term clinical and radiological findings in a prospectively followed series of 49 rheumatoid patients (58 shoulders) who had undergone Neer II total shoulder replacement. The early and intermediate results have been published previously. At a mean follow-up of 19.8 years (16.5 to 23.8) 14 shoulders survived. Proximal migration of the humeral component was associated with progressive loosening of the glenoid and humeral components, but was independent of the state of the rotator cuff at the time of operation. Despite these changes the range of movement was preserved. Most patients had little or no pain in the shoulder, could sleep undisturbed and could attend to personal hygiene and grooming


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 3 | Pages 367 - 373
1 Mar 2009
Allom R Colegate-Stone T Gee M Ismail M Sinha J

A consecutive series of 372 patients who underwent surgery for disorders of the rotator cuff involving arthroscopic subacromial decompression and open or arthroscopic repairs of the cuff were prospectively investigated as to the comparability of subjective and objective assessment scores of shoulder function. Assessments were made before operation and at 3, 6, 12, 18 and 24 months after surgery using the Disabilities of the Arm, Shoulder, and Hand score, the Oxford shoulder score and the Constant-Murley score, which was used as a reference. All scores were standardised to a scale of 0 to 100 for comparison. Statistical analysis compared the post-operative course and the mean score for the subjective Disabilities to the Arm, Shoulder and Hand score and Oxford shoulder score, with the objective Constant score at each interval. A strong correlation was evident between both subjective scores and the Constant score. We concluded that both the subjective scores would be useful substitutes for the Constant score, obviating the need for a trained investigator and the specialist equipment required to perform the Constant score


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 1 | Pages 77 - 82
1 Jan 2010
Karthikeyan S Kwong HT Upadhyay PK Parsons N Drew SJ Griffin D

We have carried out a prospective double-blind randomised controlled trial to compare the efficacy of a single subacromial injection of the non-steroidal anti-inflammatory drug, tenoxicam, with a single injection of methylprednisolone in patients with subacromial impingement. A total of 58 patients were randomly allocated into two groups. Group A received 40 mg of methylprednisolone and group B 20 mg of tenoxicam as a subacromial injection along with lignocaine. The Constant-Murley shoulder score was used as the primary outcome measure and the Disability of Arm, Shoulder and Hand (DASH) and the Oxford Shoulder Score (OSS) as secondary measures. Six weeks after injection the improvement in the Constant-Murley score was significantly greater in the methylprednisolone group (p = 0.003) than in the tenoxicam group. The improvement in the DASH score was greater in the steroid group and the difference was statistically significant and consistent two (p < 0.01), four (p < 0.01) and six weeks (p < 0.020) after the injection. The improvement in the OSS was consistently greater in the steroid group than in the tenoxicam group. Although the difference was statistically significant at two (p < 0.001) and four (p = 0.003) weeks after the injection, it was not at six weeks (p = 0.055). Subacromial injection of tenoxicam does not offer an equivalent outcome to subacromial injection of corticosteroid at six weeks. Corticosteroid is significantly better than tenoxicam for improving shoulder function in tendonitis of the rotator cuff after six weeks


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 6 | Pages 756 - 759
1 Jun 2006
Kato N Htut M Taggart M Carlstedt T Birch R

We investigated the effect of delay before nerve repair on neuropathic pain after injury to the brachial plexus. We studied 148 patients, 85 prospectively and 63 retrospectively. The mean number of avulsed spinal nerves was 3.2 (1 to 5). Pain was measured by a linear visual analogue scale and by the peripheral nerve injury scale. Early repair was more effective than delayed repair in the relief from pain and there was a strong correlation between functional recovery and relief from pain


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 4 | Pages 466 - 473
1 Apr 2008
Dawson J Doll H Boller I Fitzpatrick R Little C Rees J Jenkinson C Carr AJ

We developed a questionnaire to assess patient-reported outcome after surgery of the elbow from interviews with patients. Initially, 17 possible items with five response options were included. A prospective study of 104 patients (107 elbow operations) was carried out to analyse the underlying factor structure, dimensionality, internal and test-retest reliability, construct validity and responsiveness of the questionnaire items. This was compared with the Mayo Elbow performance score clinical scale, the Disabilities of the Arm, Shoulder and Hand questionnaire, and the Short-Form (SF-36) General Health Survey. In total, five questions were considered inappropriate, which resulted in the final 12-item questionnaire, which has been referred to as the Oxford elbow score. This comprises three unidimensional domains, ‘elbow function’, ‘pain’ and ‘social-psychological’; with each domain comprising four items with good measurement properties. This new 12-item Oxford elbow score is a valid measure of the outcome of surgery of the elbow


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 8 | Pages 1054 - 1057
1 Aug 2009
Kotwal PP Khan SA

A prospective series of 32 cases with tuberculosis of the hand and wrist is presented. The mean age of the patients was 23.9 years (3 to 65), 12 had bony disease and 20 primarily soft-tissue involvement. The metacarpal of the little finger was the most commonly involved bone. Pain and swelling were the usual presenting features and discharging sinuses were seen in three cases. All patients were given anti-tubercular chemotherapy with four drugs. Operative treatment in the form of open or arthroscopic debridement, or incision and drainage of abscesses, was performed in those cases where no response was seen after eight weeks of ATT. Hand function was evaluated by the modified score of Green and O’Brien. The mean was 58.3 (25 to 80) before treatment and 90.5 (80 to 95) at the end. The mean follow-up was for 22.4 months (6 to 43). Conservative treatment was successful in 24 patients (75%). Eight who did not respond to chemotherapy within eight weeks required surgery. Although tuberculosis of hand has a varied presentation, the majority of lesions respond to conservative treatment


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 5 | Pages 677 - 683
1 May 2005
Calvo E Granizo JJ Fernández-Yruegas D

We prospectively evaluated 61 patients treated arthroscopically for anterior instability of the shoulder at a mean follow-up of 44.5 months (24 to 100) using the Rowe scale. Those with post-operative dislocation or subluxation were considered to be failures. Logistic regression analysis was used to identify patients at increased risk of recurrence in order to develop a suitable selection system. The mean Rowe score improved from 45 pre-operatively to 86 at follow-up (p < 0.001). At least one episode of post-operative instability occurred in 11 patients (18%), although their stability improved (p = 0.018), and only three required revision. Subjectively, eight patients were dissatisfied. Age younger than 28 years, ligamentous laxity, the presence of a fracture of the glenoid rim involving more than 15% of the articular surface, and post-operative participation in contact or overhead sports were associated with a higher risk of recurrence, and scored 1, 1, 5 and 1 point, respectively. Those patients with a total score of two or more points had a relative risk of recurrence of 43% and should be treated by open surgery


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 11 | Pages 1470 - 1477
1 Nov 2007
Balg F Boileau P

There is no simple method available to identify patients who will develop recurrent instability after an arthroscopic Bankart procedure and who would be better served by an open operation. We carried out a prospective case-control study of 131 consecutive unselected patients with recurrent anterior shoulder instability who underwent this procedure using suture anchors. At follow-up after a mean of 31.2 months (24 to 52) 19 (14.5%) had recurrent instability. The following risk factors were identified: patient age under 20 years at the time of surgery; involvement in competitive or contact sports or those involving forced overhead activity; shoulder hyperlaxity; a Hill-Sachs lesion present on an anteroposterior radiograph of the shoulder in external rotation and/or loss of the sclerotic inferior glenoid contour. These factors were integrated in a 10-point pre-operative instability severity index score and tested retrospectively on the same population. Patients with a score over 6 points had an unacceptable recurrence risk of 70% (p < 0.001). On this basis we believe that an arthroscopic Bankart repair is contraindicated in these patients, to whom we now suggest a Bristow-Latarjet procedure instead


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 2 | Pages 196 - 200
1 Feb 2005
Hobby JL Venkatesh R Motkur P

In a prospective study, we have evaluated the impact of psychological disturbance on symptoms, self-reported disability and the surgical outcome in a series of 110 patients with carpal tunnel syndrome. Self-reported severity of symptoms and disability were assessed using the patient evaluation measure and the Boston carpal tunnel questionnaire. Psychological distress was assessed using the hospital anxiety and depression scale. There was a significant association between psychological disturbance and the pre-operative symptoms and disability. However, there was no significant association between pre-operative psychological disturbance and the outcome of surgery at six months. We concluded that patients with carpal tunnel syndrome should not be denied surgery because of pre-operative psychological disturbance since it does not adversely affect the surgical outcome


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 6 | Pages 757 - 761
1 Jun 2009
Nuttall D Haines JF Trail IA

In a prospective study between 2000 and 2005, 22 patients with primary osteoarthritis of the shoulder had a total shoulder arthroplasty with a standard five-pegged glenoid component, 12 with non-offset humeral head and ten with offset humeral head components. Over a period of 24 months the relative movement of the glenoid component with respect to the scapula was measured using radiostereometric analysis. Nine glenoids needed reaming for erosion. There was a significant increase in rotation about all three axes with time (p < 0.001), the largest occurring about the longitudinal axis (anteversion-retroversion), with mean values of 3.8° and 1.9° for the non-offset and offset humeral head eroded subgroups, respectively. There was also a significant difference in rotation about the anteversion-retroversion axis (p = 0.01) and the varus-valgus (p < 0.001) z-axis between the two groups. The offset humeral head group reached a plateau at early follow-up with rotation about the z-axis, whereas the mean of the non-offset humeral head group at 24 months was three times greater than that of the offset group accounting for the highly significant difference between them


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 12 | Pages 1594 - 1600
1 Dec 2009
Khan A Bunker TD Kitson JB

There are no long-term published results on the survival of a third-generation cemented total shoulder replacement. We describe a clinical and radiological study of the Aequalis total shoulder replacement for a minimum of ten years. Between September 1996 and May 1998, 39 consecutive patients underwent a primary cemented total shoulder replacement using this prosthesis. Data were collected prospectively on all patients each year, for a minimum of ten years, or until death or failure of the prosthesis. At a follow-up of at least ten years, 12 patients had died with the prosthesis intact and two had emigrated, leaving 25 available for clinical review. Of these, 13 had rheumatoid arthritis and 12 osteoarthritis. One refused radiological review leaving 24 with fresh radiographs. Survivorship at ten years was 100% for the humeral component and 92% for the glenoid component. The incidence of lucent lines was low. No humeral component was thought to be at risk and only two glenoid components. The osteoarthritic group gained a mean 65° in forward flexion and their Constant score improved by a mean 41.4 points (13 to 55). The rheumatoid group gained a mean of 24° in flexion and their Constant score improved by 29.4 points. This difference may have been due to failure of the rotator cuff in 75% of the patients with rheumatoid arthritis. Thus a third-generation total shoulder replacement gives an excellent result in patients with osteoarthritis and an intact rotator cuff. Patients with rheumatoid arthritis have a 75% risk of failure of the rotator cuff at ten years


Bone & Joint Research
Vol. 7, Issue 6 | Pages 422 - 429
1 Jun 2018
Acklin YP Zderic I Inzana JA Grechenig S Schwyn R Richards RG Gueorguiev B

Aims

Plating displaced proximal humeral fractures is associated with a high rate of screw perforation. Dynamization of the proximal screws might prevent these complications. The aim of this study was to develop and evaluate a new gliding screw concept for plating proximal humeral fractures biomechanically.

Methods

Eight pairs of three-part humeral fractures were randomly assigned for pairwise instrumentation using either a prototype gliding plate or a standard PHILOS plate, and four pairs were fixed using the gliding plate with bone cement augmentation of its proximal screws. The specimens were cyclically tested under progressively increasing loading until perforation of a screw. Telescoping of a screw, varus tilting and screw migration were recorded using optical motion tracking.


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 4 | Pages 501 - 507
1 Apr 2005
Krasny C Enenkel M Aigner N Wlk M Landsiedl F

We carried out a prospective, randomised controlled trial on two groups of 40 patients with painful calcific tendonitis and a mean age of 48.4 years (32.5 to 67.3). All were to undergo arthroscopic removal of the calcific deposit within six months after randomisation. The 40 patients in group I received ultrasound-guided needling followed by high-energy shock-wave therapy and the 40 in group II had shock-wave therapy alone. In both groups one treatment consisting of 2500 impulses of shock waves with an energy flux density of 0.36 mJ/mm. 2. was applied. The clinical and radiological outcome was assessed using the 100-point Constant shoulder scoring system and standardised radiographs. The mean follow-up was 4.1 months and no patient was lost to follow-up. Both groups had significant improvement in their Constant shoulder score. Radiographs showed disappearance of the calcific deposit in 60.0% of the shoulders in group I and in 32.5% of group II (p < 0.05). Significantly better clinical and radiological results were obtained in group I than in group II. Arthroscopic removal of the deposit was avoided in 32 patients of group I and in 22 of group II. No severe side-effects were recorded. Ultrasound-guided needling in combination with high-energy shock-wave therapy is more effective than shock-wave therapy alone in patients with symptomatic calcific tendonitis, giving significantly higher rates of elimination of the calcium deposits, better clinical results and reduction in the need for surgery


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 7 | Pages 933 - 939
1 Jul 2007
Ya’ish F Cooper JP Craigen MAC

The diagnosis of nerve injury using thermotropic liquid crystal temperature strips was compared blindly and prospectively against operative findings in 36 patients requiring surgical exploration for unilateral upper limb lacerations with suspected nerve injury. Thermotropic liquid crystal strips were applied to affected and non-affected segments in both hands in all subjects. A pilot study showed that a simple unilateral laceration without nerve injury results in a cutaneous temperature difference between limbs, but not within each limb. Thus, for detection of a nerve injury, comparison was made against the unaffected nerve distribution in the same hand. Receiver operating characteristic curve analysis showed that an absolute temperature difference ≥ 1.0°C was diagnostic of a nerve injury (area under the curve = 0.985, sensitivity = 100%, specificity = 93.8%). Thermotropic liquid crystal strip assessment is a new, reliable and objective method for the diagnosis of traumatic peripheral nerve injuries. If implemented in the acute setting, it could improve the reliability of clinical assessment and reduce the number of negative surgical explorations


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 10 | Pages 1341 - 1347
1 Oct 2008
Levy O Venkateswaran B Even T Ravenscroft M Copeland S

We have conducted a prospective study to assess the mid-term clinical results following arthroscopic repair of the rotator cuff. Patients were evaluated using the Constant score, subjective satisfaction levels and post-operative ultrasound scans. Of 115 consecutive patients who underwent arthroscopic repair of the rotator cuff at our institution, 102 were available for follow-up. The mean period of follow-up was for 35.8 months (24 to 73). The mean age of the patients was 57.3 years (23 to 78). There were 18 small (≤ 1 cm in diameter), 44 medium (1 cm to 3 cm in diameter), 34 large (3 cm to 5 cm in diameter) and six massive (> 5 cm in diameter) tears. There was a statistically significant increase in the size of the tear with increasing age (p = 0.0048). The mean pre-operative Constant score was 41.4 points (95% confidence interval, 37.9 to 44.9), which improved to 84.5 (95% confidence interval, 82.2 to 86.9). A significant inverse association (p = 0.0074), was observed between the size of the tear and the post-operative Constant score, with patients having smaller tears attaining higher Constant scores after repair. Post-operatively, 80 patients (78.4%) were able to resume their occupations and 84 (82.4%) returned to their pre-injury leisure activities. Only eight (7.8%) of 102 patients were not satisfied with the outcome. Recurrent tears were detected by ultrasound in 19 (18.6%) patients, and were generally smaller than the original ones. Patients with recurrent tears experienced a mean improvement of 31.6 points (95% confidence interval, 23.6 to 39.6) in their post-operative Constant scores. Those with intact repairs had significantly improved (p < 0.0001) Constant scores (mean improvement 46.3 points, 95% confidence interval, 41.9 to 50.6). Patient satisfaction was high in 94 cases (92%), irrespective of the outcome of the Constant score. Recurrent tears appear to be linked to age-related degeneration. Arthroscopic repair of the rotator cuff leads to high rates of satisfaction (92%) and good functional results, albeit with a recurrence rate of 18.6% (19 of 102)


Objectives. Local corticosteroid infiltration is a common practice of treatment for lateral epicondylitis. In recent studies no statistically significant or clinically relevant results in favour of corticosteroid injections were found. The injection of autologous blood has been reported to be effective for both intermediate and long-term outcomes. It is hypothesised that blood contains growth factors, which induce the healing cascade. Methods. A total of 60 patients were included in this prospective randomised study: 30 patients received 2 ml autologous blood drawn from contralateral upper limb vein + 1 ml 0.5% bupivacaine, and 30 patients received 2 ml local corticosteroid + 1 ml 0.5% bupivacaine at the lateral epicondyle. Outcome was measured using a pain score and Nirschl staging of lateral epicondylitis. Follow-up was continued for total of six months, with assessment at one week, four weeks, 12 weeks and six months. Results. The corticosteroid injection group showed a statistically significant decrease in pain compared with autologous blood injection group in both visual analogue scale (VAS) and Nirschl stage at one week (both p < 0.001) and at four weeks (p = 0.002 and p = 0.018, respectively). At the 12-week and six-month follow-up, autologous blood injection group showed statistically significant decrease in pain compared with corticosteroid injection group (12 weeks: VAS p = 0.013 and Nirschl stage p = 0.018; six months: VAS p = 0.006 and Nirschl p = 0.006). At the six-month final follow-up, a total of 14 patients (47%) in the corticosteroid injection group and 27 patients (90%) in autologous blood injection group were completely relieved of pain. Conclusions. Autologous blood injection is efficient compared with corticosteroid injection, with less side-effects and minimum recurrence rate


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 2 | Pages 213 - 219
1 Feb 2006
Kambhampati SBS Birch R Cobiella C Chen L

We describe the results of surgical treatment in a prospective study of 183 consecutive cases of subluxation (101) and dislocation (82) of the shoulder secondary to obstetric brachial plexus palsy between 1995 and 2000. Neurological recovery was rated ‘good’ or ‘useful’ in all children, whose lesions fell into groups 1, 2 or 3 of the Narakas classification. The mean age at operation was 47 months (3 to 204). The mean follow-up was 40 months (24 to 124). The mean gain in function was 3.6 levels (9.4 to 13) using the Mallet score and 2 (2.1 to 4.1) on the Gilbert score. The mean active global range of shoulder movement was increased by 73°; the mean range of active lateral rotation by 58° and that of supination of the forearm by 51°. Active medial rotation was decreased by a mean of 10°. There were 20 failures. The functional outcome is related to the severity of the neurological lesion, the duration of the dislocation and onset of deformity


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 4 | Pages 496 - 501
1 Apr 2006
Haines JF Trail IA Nuttall D Birch A Barrow A

We have undertaken a prospective clinical and radiological analysis of 124 shoulder arthroplasties (113 patients) carried out for osteoarthritis. The clinical results showed improvement in the absolute Constant score and the American Shoulder and Elbow Surgeons score of 22 and 43, respectively. Both were statistically significant (p < 0.001). There was no significant difference in the scores after hemiarthroplasty and total arthroplasty in those patients with an intact rotator cuff. When revision was used as the end-point for survival at ten years, survival of 86%, or 90% if glenoid components made of Hylamer sterilised in air were omitted, was obtained in primary osteoarthritis. The most common cause for revision in the hemiarthroplasty group was glenoid pain at a mean of 1.5 years; in the total arthroplasty group it was loosening of the glenoid at a mean of 4.5 years. Analysis of pre-operative factors showed that the risk of gross loosening of the glenoid increased threefold when there was evidence of erosion of the glenoid at operation. Shoulder arthroplasty should not be delayed once symptomatic osteoarthritis has been established and should be undertaken before failure of the cuff or erosion of the glenoid are present


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 3 | Pages 335 - 341
1 Mar 2007
Albert J Meadeb J Guggenbuhl P Marin F Benkalfate T Thomazeau H Chalès G

In a prospective randomised trial of calcifying tendinitis of the rotator cuff, we compared the efficacy of dual treatment sessions delivering 2500 extracorporeal shock waves at either high- or low-energy, via an electromagnetic generator under fluoroscopic guidance. Patients were eligible for the study if they had more than a three-month history of calcifying tendinitis of the rotator cuff, with calcification measuring 10 mm or more in maximum dimension. The primary outcome measure was the change in the Constant and Murley Score. A total of 80 patients were enrolled (40 in each group), and were re-evaluated at a mean of 110 (41 to 255) days after treatment when the increase in Constant and Murley score was significantly greater (t-test, p = 0.026) in the high-energy treatment group than in the low-energy group. The improvement from the baseline level was significant in the high-energy group, with a mean gain of 12.5 (−20.7 to 47.5) points (p < 0.0001). The improvement was not significant in the low-energy group. Total or subtotal resorption of the calcification occurred in six patients (15%) in the high-energy group and in two patients (5%) in the low-energy group. High-energy shock-wave therapy significantly improves symptoms in refractory calcifying tendinitis of the shoulder after three months of follow-up, but the calcific deposit remains unchanged in size in the majority of patients


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 2 | Pages 235 - 241
1 Feb 2010
van der Lugt JCT Valstar ER Witvoet-Braam SW Nelissen RGHH

Mechanical loosening which begins with early-onset migration of the prosthesis is the major reason for failure of the Souter-Strathclyde elbow replacement. In a prospective study of 18 Souter-Strathclyde replacements we evaluated the patterns of migration using roentgen stereophotogrammetric analysis. We had previously reported the short-term results after a follow-up of two years which we have now extended to a mean follow-up of 8.2 years (1 to 11.3). Migration was assessed along the co-ordinal axes and overall micromovement was expressed as the maximum total point movement. The alignment of the prosthesis and the presence of radiolucent lines were examined on conventional standardised radiographs. All the humeral components showed increased and variable patterns of migration at the extended follow-up and four humeral components were revised. The maximum total point movement at two years in the revised prostheses was 1.8 mm (. sd. 1.0) and in the non-revised 0.7 mm (. sd. 0.5, p = 0.01). Most humeral components migrated into external rotation resulting in an anterior and varus tilt. The ulnar components remained stable


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 6 | Pages 762 - 765
1 Jun 2009
Toros T Karabay N Özaksar K Sugun TS Kayalar M Bal E

We prospectively studied 26 consecutive patients with clinically documented sensory or motor deficiency of a peripheral nerve due to trauma or entrapment using ultrasound, and in 19 cases surgical exploration of the nerves was undertaken. The ultrasonographic diagnoses were correlated with neurological examination and the surgical findings. Reliable visualisation of injured nerves on ultrasonography was achieved in all patients. Axonal swelling and hypoechogenity of the nerve was diagnosed in 15 cases, loss of continuity of a nerve bundle in 17, the formation of a neuroma of a stump in six, and partial laceration of a nerve with loss of the normal fascicular pattern in five. The ultrasonographic findings were confirmed at operation in those who had surgery. Ultrasound may be used for the evaluation of peripheral nerve injuries in the upper limb. High-resolution ultrasound can show the exact location, extent and type of lesion, yielding important information that might not be obtainable by other diagnostic aids


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 9 | Pages 1197 - 1200
1 Sep 2007
Quraishi NA Johnston P Bayer J Crowe M Chakrabarti AJ

This study prospectively evaluated the outcome of manipulation under anaesthesia and hydrodilatation as treatments for adhesive capsulitis. A total of 36 patients (38 shoulders) were randomised to receive either method, with all patients being treated in stage II of the disease process. The mean age of the patients was 55.2 years (44 to 70) and the mean duration of symptoms was 33.7 weeks (12 to 76). Eighteen shoulders (17 patients) underwent manipulation under anaesthesia and 20 (19 patients) had hydrodilatation. There were three insulin-dependent diabetics in each group. The mean visual analogue score in the manipulation under anaesthesia group was 5.7 (3 to 8.5; n = 18) before treatment, 4.7 (0 to 8.5; n = 16) at two months (paired t-test p = 0.02), and 2.7 (0 to 9; n = 16) at six months (paired t-test, p = 0.0006). The mean score in the hydrodilatation group was 6.1 (4 to 10; n = 20) before treatment, 2.4 (0 to 8; n = 18) at two months (paired t-test, p = 0.001), and 1.7 (0 to 7; n = 18) at six months (paired t-test, p = 0.0006). The visual analogue scores in the hydrodilatation group were significantly better than in the manipulation under anaesthesia group over the six-month follow-up period (p < 0.0001). The mean Constant score in those manipulated was 36 (26 to 66) before treatment, 58.5 (24 to 90) at two months (paired t-test, p = 0.001) and 59.5 (23 to 85) at six months (paired t-test, p = 0.0006). In the hydrodilatation group it was 28.8 (18 to 55) before treatment, 57.4 (17 to 80) at two months (paired t-test, p = 0.0004) and 65.9 (28 to 92) at six months (paired t-test, p = 0.0005). The Constant scores in the hydrodilatation group were significantly better than in the manipulated group over the six-month period of follow-up (p = 0.02). The range of movement improved in all patients over the six months, but was not significantly different between the groups. At the final follow-up, 94% of patients (17 of 18) were satisfied or very satisfied after hydrodilatation compared with 81% (13 of 16) of those receiving a manipulation. Most of our patients were treated successfully, but those undergoing hydrodilatation did better than those who were manipulated


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 2 | Pages 196 - 201
1 Feb 2007
Veitch S Blake SM David H

We prospectively reviewed 14 patients with deficiency of the proximal pole of the scaphoid who were treated by rib osteochondral replacement arthroplasty. Improvement in wrist function occurred in all except one patient with enhanced grip strength, less pain and maintenance of wrist movement. In 13 patients wrist function was rated as good or excellent according to the modified wrist function score of Green and O’Brien. The mean pre-operative score of 54 (35 to 80) rose to 79 (50 to 90) at review at a mean of 64 months (27 to 103). Carpal alignment did not deteriorate in any patient and there were no cases of nonunion or significant complications. This procedure can restore the mechanical integrity of the proximal pole of the scaphoid satisfactorily and maintain wrist movement while avoiding the potential complications of alternative replacement arthroplasty techniques and problems associated with vascularised grafts and salvage techniques


The Journal of Bone & Joint Surgery British Volume
Vol. 85-B, Issue 7 | Pages 1016 - 1018
1 Sep 2003
Mader K Gausepohl T Wolfgarten B Pennig D

Our aim in this prospective study was to evaluate a minimally invasive technique for percutaneous arthrodesis of the small joints in the hand. Thirteen arthrodeses were undertaken in 11 patients, eight women and three men. After the percutaneous removal of articular cartilage, the bony surfaces were aligned in a predetermined position and stabilised using a percutaneous screw system. The mean follow-up was 38.6 months (36 to 56). Bony union was achieved in 12 cases (ten patients) between nine and 12 weeks after surgery. In one patient a second operation was required to obtain union and another developed a painless nonunion after premature removal of the implants


The Journal of Bone & Joint Surgery British Volume
Vol. 83-B, Issue 5 | Pages 635 - 639
1 Jul 2001
Redfern DRM Dunkley AB Trail IA Stanley JK

The Souter-Strathclyde prosthesis was used in 52 revisions of total elbow replacements (TERs) between August 1986 and May 1997. Of these, 50, carried out in 45 patients, were prospectively followed for a mean of 53 months (14 to 139). The procedure produced reliable relief of pain, and the range of movement was preserved. There was a considerable incidence of adverse events associated with revision (30%), and 12 further procedures have been required. Nonetheless, a revision is the preferred salvage procedure for failed primary arthroplasty in the absence of sepsis


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 4 | Pages 502 - 508
1 Apr 2006
Robinson CM Khan LAK Akhtar MA

Over a seven-year period we treated a consecutive series of 58 patients, 20 men and 38 women with a mean age of 66 years (21 to 87) who had an acute complex anterior fracture-dislocation of the proximal humerus. Two patterns of injury are proposed for study based upon a prospective assessment of the pattern of soft-tissue and bony injury and the degree of devascularisation of the humeral head. In 23 patients, the head had retained capsular attachments and arterial back-bleeding (type-I injury), whereas in 35 patients the head was devoid of significant soft-tissue attachments with no active arterial bleeding (type-II injury). Following treatment by open reduction and internal fixation, only two of 23 patients with type-I injuries developed radiological evidence of osteonecrosis of the humeral head, compared with four of seven patients with type-II injuries. A policy of primary treatment by open reduction and internal fixation of type-I injuries is justified, whereas most elderly patients (aged 60 years or over) with type-II injuries are best treated by hemiarthroplasty. The best treatment for younger patients (aged under 60 years) who sustain type-II injuries is controversial and an individualised approach to their management is advocated


The Journal of Bone & Joint Surgery British Volume
Vol. 82-B, Issue 7 | Pages 1011 - 1012
1 Sep 2000
Huracek J Troeger H

We describe a technique for arthroscopy of the wrist which is carried out without traction and with the arm lying horizontally on the operating table. The wrist is not immobilised, which makes it possible to assess the extent of instability after a ligamentous tear. In a prospective study of 30 patients we compared this technique with conventional wrist arthroscopy, performing the new method first followed by conventional arthroscopy. The advantages are that the horizontal position of the arm allows the surgeon to proceed directly from arthroscopic diagnosis to treatment, and that no change of position is required for fluoroscopy. In terms of diagnostic sensitivity, we found our technique matched that of conventional arthroscopy. We had no difficulty in carrying out minor surgical procedures such as debridement and suturing


The Journal of Bone & Joint Surgery British Volume
Vol. 78-B, Issue 5 | Pages 777 - 779
1 Sep 1996
Geutjens GG Langstaff RJ Smith NJ Jefferson D Howell CJ Barton NJ

We carried out a prospective randomised study comparing medial epicondylectomy with anterior transposition for the treatment of ulnar neuropathy at the elbow. The mean follow-up period was 4.5 years and we assessed the patients neurologically and orthopaedically. Neither procedure appeared to have a significant effect on elbow function. Our study showed better results after medial epicondylectomy; in particular patient satisfaction was higher than after ulnar nerve transposition. There were no significant differences in motor power or nerve-conduction rates and sensory fibres appeared to be more vulnerable to devascularisation


The Journal of Bone & Joint Surgery British Volume
Vol. 86-B, Issue 5 | Pages 701 - 704
1 Jul 2004
Dunkow PD Jatti M Muddu BN

We conducted a prospective, randomised, controlled trial of 45 patients (47 elbows), with tennis elbow, who underwent either a formal open release or a percutaneous tenotomy. All patients had pre- and post-operative assessment using the Disability of Arm, Shoulder and Hand (DASH) scoring system. Both groups were followed up for a minimum of 12 months. Statistical analyses using the Mann-Whitney U test and repeated measured ANOVA showed significant improvements for patient satisfaction (p = 0.012), time to return to work (p = 0.0001), improvements in DASH score (p = 0.001) and improvement in sporting activities (p = 0.046) in the percutaneous group. Those patients undergoing a percutaneous release returned to work on average three weeks earlier and improved significantly more quickly than those undergoing an open procedure. The percutaneous procedure is a quicker and simpler procedure to undertake and produces significantly better results


The Journal of Bone & Joint Surgery British Volume
Vol. 86-B, Issue 7 | Pages 991 - 997
1 Sep 2004
Scheibel M Bartl C Magosch P Lichtenberg S Habermeyer P

We performed eight osteochondral autologous transplantations from the knee joint to the shoulder. All patients (six men, two women; mean age 43.1 years) were documented prospectively. In each patient the stage of the osteochondral lesion was Outerbridge grade IV with a mean size of the affected area of 150 mm. 2. All patients were assessed by using the Constant score for the shoulder and the Lysholm score for the knee. Standard radiographs, magnetic resonance imaging and second-look arthroscopy were used to assess the presence of glenohumeral osteoarthritis and the integrity of the grafts. After a mean of 32.6 months (8 to 47), the mean Constant score increased significantly. Magnetic resonance imaging revealed good osseointegration of the osteochondral plugs and congruent articular cartilage at the transplantation site in all but one patient. Second-look arthroscopy performed in two cases revealed a macroscopically good integration of the autograft with an intact articular surface. Osteochondral autologous transplantation in the shoulder appears to offer good clinical results for treating full-thickness osteochondral lesions of the glenohumeral joint. However, our study suggests that the development of osteoarthritis and the progression of pre-existing osteoarthritic changes cannot be altered by this technique


The Journal of Bone & Joint Surgery British Volume
Vol. 81-B, Issue 4 | Pages 679 - 685
1 Jul 1999
Visser CPJ Coene LNJEM Brand R Tavy DLJ

Opinion varies as to the incidence of nerve lesions in anterior dislocation of the shoulder after low-velocity trauma. Most studies are retrospective or do not use EMG. We have investigated the incidence and the clinical consequences of nerve lesions in a prospective study by clinical and electrophysiological examination. Axonal loss was seen in 48% of 77 patients. The axillary nerve was most frequently involved (42%). Although recovery as judged by EMG and muscle strength was almost complete, function of the shoulder was significantly impaired in patients with lesions of the axillary and suprascapular nerves. Unfavourable prognostic factors are increasing age and the presence of a haematoma. It is not necessary to carry out EMG routinely; an adequate programme of physiotherapy is important. In patients with a severe paresis, EMG is essential after three weeks


The Journal of Bone & Joint Surgery British Volume
Vol. 81-B, Issue 3 | Pages 420 - 426
1 May 1999
Dawson J Fitzpatrick R Carr A

We have developed a 12-item questionnaire for completion by patients presenting with shoulder instability. A prospective study of 92 patients was undertaken involving two assessments, approximately six months apart, performed in an outpatient department. Each patient completed the new questionnaire and the SF36 form. An orthopaedic surgeon completed the Constant shoulder score and the Rowe assessment. The new questionnaire and the Rowe clinical score each achieved a large standardised effect size (≥0.8) and compared favourably with relevant items on the SF36. By contrast, the Constant score barely registered any effect, confirming that it may be relatively insensitive to changes in clinical status for this particular condition. The questionnaire provides a measurement of outcome for shoulder instability which is short, practical, reliable, valid and sensitive to changes of clinical importance


The Journal of Bone & Joint Surgery British Volume
Vol. 80-B, Issue 5 | Pages 817 - 824
1 Sep 1998
dos Reis FB Katchburian MV Faloppa F Albertoni WM Filho JL

The Madelung deformity can result in pain and decreased function of the wrist and hand. None of the surgical techniques available has been shown consistently to improve grip strength, range of movement or relieve pain. In this prospective study we have treated 18 patients with the Madelung deformity (25 wrists) by wedge subtraction osteotomy of the radius and shortening of the ulna. Our results show statistically significant improvement in grip strength and range of movement of the wrist and forearm. Pain improved in 80% of the patients and 88% were satisfied with the appearance. One patient had a wound infection and another developed reflex sympathetic dystrophy. Two had some recurrence due to continued growth of the ulna and it is recommended that the procedure be delayed until skeletal maturity, or else combined with epiphysiodesis of the ulna


The Journal of Bone & Joint Surgery British Volume
Vol. 81-B, Issue 5 | Pages 863 - 867
1 Sep 1999
Loew M Daecke W Kusnierczak D Rahmanzadeh M Ewerbeck V

We report a prospective study of the effects of extracorporeal shock-wave therapy in 195 patients with chronic calcifying tendinitis. In part A 80 patients with chronic symptoms were randomly assigned to a control and three subgroups which had different treatment by low-energy and high-energy shock waves. In part B 115 patients had either one or two high-energy sessions. We recorded subjective, functional and radiological findings at six months after treatment. The results showed energy-dependent success, with relief of pain ranging from 5% in our control group up to 58% after two high-energy sessions. The Constant scores and the radiological disintegration of calcification were also dose-dependent. Shockwave therapy should be considered for chronic pain due to calcific tendinitis which is resistant to conservative treatment


The Journal of Bone & Joint Surgery British Volume
Vol. 78-B, Issue 2 | Pages 233 - 237
1 Mar 1996
Rompe JD Hopf C Küllmer K Heine J Bürger R

We report a controlled, prospective study to investigate the effect of treatment by low-energy extracorporeal shock waves on pain in tennis elbow. We assigned at random 100 patients who had had symptoms for more than 12 months to two groups to receive low-energy shock-wave therapy. Group I received a total of 3000 impulses of 0.08 mJ/mm. 2. and group II, the control group, 30 impulses. The patients were reviewed after 3, 6 and 24 weeks. There was significant alleviation of pain and improvement of function after treatment in group I in which there was a good or excellent outcome in 48% and an acceptable result in 42% at the final review, compared with 6% and 24%, respectively, in group II


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 8 | Pages 1089 - 1095
1 Aug 2005
Birch R Ahad N Kono H Smith S

This is a prospective study of 107 repairs of obstetric brachial plexus palsy carried out between January 1990 and December 1999. The results in 100 children are presented. In partial lesions operation was advised when paralysis of abduction of the shoulder and of flexion of the elbow persisted after the age of three months and neurophysiological investigations predicted a poor prognosis. Operation was carried out earlier at about two months in complete lesions showing no sign of clinical recovery and with unfavourable neurophysiological investigations. Twelve children presented at the age of 12 months or more; in three more repair was undertaken after earlier unsuccessful neurolysis. The median age at operation was four months, the mean seven months and a total of 237 spinal nerves were repaired. The mean duration of follow-up after operation was 85 months (30 to 152). Good results were obtained in 33% of repairs of C5, in 55% of C6, in 24% of C7 and in 57% of operations on C8 and T1. No statistical difference was seen between a repair of C5 by graft or nerve transfer. Posterior dislocation of the shoulder was observed in 30 cases. All were successfully relocated after the age of one year. In these children the results of repairs of C5 were reduced by a mean of 0.8 on the Gilbert score and 1.6 on the Mallett score. Pre-operative electrodiagnosis is a reliable indicator of the depth of the lesion and of the outcome after repair. Intra-operative somatosensory evoked potentials were helpful in the detection of occult intradural (pre-ganglionic) injury


The Journal of Bone & Joint Surgery British Volume
Vol. 80-B, Issue 6 | Pages 1024 - 1030
1 Nov 1998
Waikakul S Vanadurongwan V Unnanuntana A

We performed a prospective study in 186 patients with a minimum follow-up of two years in order to attempt to predict successful major re-implantation of the upper limb. There were 137 men and 49 women with 24 amputations of the palm, 75 of the wrist, 50 of the forearm, 9 disarticulations through the elbow, and 28 amputations through the upper arm. The degree of injury to the amputated segment and the stump were good predictors of the rate of success and the final outcome. Adequate preservation, contraction of the muscle in the amputated part after stimulation, the level of injury and a smoking habit were fair indicators, but the serum potassium concentration in the amputated segment was the best objective predictor. When it is higher than 6.5 mmol/l 30 minutes after re-perfusion, re-implantation should be avoided. A high systemic venous serum potassium concentration was also found before clinical signs of the re-perfusion syndrome were seen


The Journal of Bone & Joint Surgery British Volume
Vol. 84-B, Issue 7 | Pages 967 - 970
1 Sep 2002
Karnezis IA Fragkiadakis EG

Although the outcome of fractures of the distal radius is traditionally assessed using objective clinical variables such as grip strength and range of movement of the wrist, the extent to which they reflect function and outcomes of importance for the patient is uncertain. This may cause considerable inconsistencies in the assessment of outcome using current scoring systems. We prospectively studied 31 patients recovering from unstable fractures of the distal radius in order to investigate the association between objective variables and the level of post-traumatic disability of the wrist as measured by the patient-rated wrist evaluation (PRWE) score. Multiple regression showed considerable differences in the extent to which limitations in specific objective clinical variables reflected the level of disability of the wrist. Grip strength was shown to be a significant predictor of the PRWE score (regression coefficient −1.09, 95% confidence interval −1.76 to −0.42, p < 0.01) and thus appears to be a sensitive indicator of return of function of the wrist. Forearm rotation and flexion and extension of the wrist were not significantly associated with the PRWE score. These observations should be taken into account during the evaluation of methods of treatment and in constructing future clinical outcome scoring systems


The Journal of Bone & Joint Surgery British Volume
Vol. 78-B, Issue 1 | Pages 128 - 132
1 Jan 1996
Verhaar JAN Walenkamp GHIM van Mameren H Kester ADM van der Linden AJ

We performed a prospective, randomised trial on 106 patients to compare the effects of local corticosteroid injections with physiotherapy as advocated by Cyriax in the treatment of tennis elbow. The main outcome measures were the severity of pain, pain provoked by resisted dorsiflexion of the wrist, and patient satisfaction. At six weeks 22 of 53 patients in the injection group were free from pain compared with only three in the physiotherapy group. In the corticosteroid-treated group 26 patients had no pain on resisted dorsiflexion of the wrist compared with only three in the physiotherapy group. Thirty-five patients who had injections and 14 who had physiotherapy were satisfied with the outcome of treatment at six weeks. At the final assessment there were 18 excellent and 18 good results in the corticosteroid group and one excellent and 12 good results in the physiotherapy group. There was a significant increase in grip strength in both groups but those with injections had a significantly better result. After one year there were no significant differences between the two groups. Half of the patients, however, had received only the initial treatment, 20% had had combined therapy and 30% had had surgery. We conclude that at six weeks, treatment with corticosteroid injections was more effective than Cyriax physiotherapy and we recommend it because of its rapid action, reduction of pain and absence of side-effects


The Bone & Joint Journal
Vol. 98-B, Issue 4 | Pages 519 - 525
1 Apr 2016
Lees DA Penny JB Baker P

Aims

The aim of this study was to compare the pain caused by the application of a tourniquet after exsanguination of the upper limb with that occurring after simple elevation.

Patients and Methods

We used 26 healthy volunteers (52 arms), each of whom acted as their own matched control.

The primary outcome measure was the total pain experienced by each volunteer while the tourniquet was inflated for 20 minutes. This was calculated as the area under the pain curve for each individual subject. Secondary outcomes were pain at each time point; the total pain experienced during the recovery phase; the ability to tolerate the tourniquet and the time for full recovery after deflation of the tourniquet.


The Bone & Joint Journal
Vol. 96-B, Issue 11 | Pages 1530 - 1534
1 Nov 2014
Uehara K Yasunaga H Morizaki Y Horiguchi H Fushimi K Tanaka S

Necrotising soft-tissue infections (NSTIs) of the upper limb are uncommon, but potentially life-threatening. We used a national database to investigate the risk factors for amputation of the limb and death.

We extracted data from the Japanese Diagnosis Procedure Combination database on 116 patients (79 men and 37 women) who had a NSTI of the upper extremity between 2007 and 2010.

The overall in-hospital mortality was 15.5%. Univariate analysis of in-hospital mortality showed that the significant variables were age (p = 0.015), liver dysfunction (p = 0.005), renal dysfunction (P < 0.001), altered consciousness (p = 0.049), and sepsis (p = 0.021). Logistic regression analysis showed that the factors associated with death in hospital were age over 70 years (Odds Ratio (OR) 6.6; 95% confidence interval (CI) 1.5 to 28.2; p = 0.011) and renal dysfunction (OR 15.4; 95% CI 3.8 to 62.8; p < 0.001).

Univariate analysis of limb amputation showed that the significant variables were diabetes (p = 0.017) mellitus and sepsis (p = 0.001). Multivariable logistic regression analysis showed that the factors related to limb amputation were sepsis (OR 1.8; 95% CI 1.5 to 24.0; p = 0.013) and diabetes mellitus (OR 1.6; 95% CI 1.1 to 21.1; p = 0.038).

For NSTIs of the upper extremity, advanced age and renal dysfunction are both associated with a higher rate of in-hospital mortality. Sepsis and diabetes mellitus are both associated with a higher rate of amputation.

Cite this article: Bone Joint J 2014;96-B:1530–4.


The Bone & Joint Journal
Vol. 95-B, Issue 7 | Pages 947 - 951
1 Jul 2013
Kang HJ Koh IH Jang JW Choi YR

The purpose of this study was to compare the outcome and complications of endoscopic versus open release for the treatment of de Quervain’s tenosynovitis. Patients with this condition were randomised to undergo either endoscopic (n = 27) or open release (n = 25). Visual Analogue Scale (VAS) pain and Disabilities of Arm, Shoulder, and Hand (DASH) scores were measured at 12 and 24 weeks after surgery. Scar satisfaction was measured using a VAS scale. The mean pain and DASH scores improved significantly at 12 weeks and 24 weeks (p <  0.001) in both groups. The scores were marginally lower in the endoscopic group compared to the open group at 12 weeks (p = 0.012 and p = 0.002, respectively); however, only the DASH score showed a clinically important difference. There were no differences between the groups at 24 weeks. The mean VAS scar satisfaction score was higher in the endoscopic group at 24 weeks (p < 0.001). Transient superficial radial nerve injury occurred in three patients in the endoscopic group compared with nine in the open release group (p = 0.033).

We conclude that endoscopic release for de Quervain’s tenosynovitis seems to provide earlier improvement after surgery, with fewer superficial radial nerve complications and greater scar satisfaction, when compared with open release.

Cite this article: Bone Joint J 2013;95-B:947–51.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 10 | Pages 1305 - 1312
1 Oct 2012
Adams J Ryall C Pandyan A Metcalf C Stokes M Bradley S Warwick DJ

We systematically reviewed all the evidence published in the English language on proximal interphalangeal joint (PIPJ) replacement, to determine its effectiveness on the function of the hand and the associated post-operative complications.

Original studies were selected if they reported clinical outcome with a minimum of one year’s follow-up. Quality was assessed using the Cowley systematic review criteria modified for finger-joint replacements. Of 319 articles identified, only five were adequately reported according to our quality criteria; there were no randomised controlled trials. PIPJ replacements had a substantial effect size on hand pain of -23.2 (95% confidence interval (CI) -27.3 to -19.1) and grip strength 1.2 (95% CI -10.7 to 13.1), and a small effect on range of movement 0.2 (95% CI -0.4 to 0.8). A dorsal approach was most successful. Post-operative loosening occurred in 10% (95% CI 3 to 30) of ceramic and 12.5% (95% CI 7 to 21) of pyrocarbon replacements. Post-operative complications occurred in 27.8% (95% CI 20 to 37).

We conclude that the effectiveness of PIPJ replacement has not been established. Small observational case studies and short-term follow-up, together with insufficient reporting of patient data, functional outcomes and complications, limit the value of current evidence.

We recommend that a defined core set of patients, surgical and outcome data for this intervention be routinely and systematically collected within the framework of a joint registry.


Bone & Joint Research
Vol. 2, Issue 7 | Pages 122 - 128
1 Jul 2013
Mukovozov I Byun S Farrokhyar F Wong I

Aims

We performed a systematic review of the literature to determine whether earlier surgical repair of acute rotator cuff tear (ARCT) leads to superior post-operative clinical outcomes.

Methods

The MEDLINE, Embase, CINAHL, Web of Science, Cochrane Libraries, controlled-trials.com and clinicaltrials.gov databases were searched using the terms: ‘rotator cuff’, or ‘supraspinatus’, or ‘infraspinatus’, or ‘teres minor’, or ‘subscapularis’ AND ‘surgery’ or ‘repair’. This gave a total of 15 833 articles. After deletion of duplicates and the review of abstracts and full texts by two independent assessors, 15 studies reporting time to surgery for ARCT repair were included. Studies were grouped based on time to surgery < 3 months (group A, seven studies), or > 3 months (group B, eight studies). Weighted means were calculated and compared using Student’s t-test.


Bone & Joint Research
Vol. 3, Issue 2 | Pages 38 - 47
1 Feb 2014
Hogendoorn S Duijnisveld BJ van Duinen SG Stoel BC van Dijk JG Fibbe WE Nelissen RGHH

Objectives

Traumatic brachial plexus injury causes severe functional impairment of the arm. Elbow flexion is often affected. Nerve surgery or tendon transfers provide the only means to obtain improved elbow flexion. Unfortunately, the functionality of the arm often remains insufficient. Stem cell therapy could potentially improve muscle strength and avoid muscle-tendon transfer. This pilot study assesses the safety and regenerative potential of autologous bone marrow-derived mononuclear cell injection in partially denervated biceps.

Methods

Nine brachial plexus patients with insufficient elbow flexion (i.e., partial denervation) received intramuscular escalating doses of autologous bone marrow-derived mononuclear cells, combined with tendon transfers. Effect parameters included biceps biopsies, motor unit analysis on needle electromyography and computerised muscle tomography, before and after cell therapy.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 6 | Pages 811 - 814
1 Jun 2012
Jenkins PJ Duckworth AD Watts AC McEachan JE

Diabetes mellitus is recognised as a risk factor for carpal tunnel syndrome. The response to treatment is unclear, and may be poorer than in non-diabetic patients. Previous randomised studies of interventions for carpal tunnel syndrome have specifically excluded diabetic patients. The aim of this study was to investigate the epidemiology of carpal tunnel syndrome in diabetic patients, and compare the outcome of carpal tunnel decompression with non-diabetic patients. The primary endpoint was improvement in the QuickDASH score. The prevalence of diabetes mellitus was 11.3% (176 of 1564). Diabetic patients were more likely to have severe neurophysiological findings at presentation. Patients with diabetes had poorer QuickDASH scores at one year post-operatively (p = 0.028), although the mean difference was lower than the minimal clinically important difference for this score. After controlling for underlying differences in age and gender, there was no difference between groups in the magnitude of improvement after decompression (p = 0.481). Patients with diabetes mellitus can therefore be expected to enjoy a similar improvement in function.


The Bone & Joint Journal
Vol. 95-B, Issue 5 | Pages 660 - 663
1 May 2013
Ghosh S Singh VK Jeyaseelan L Sinisi M Fox M

In adults with brachial plexus injuries, lack of active external rotation at the shoulder is one of the most common residual deficits, significantly compromising upper limb function. There is a paucity of evidence to address this complex issue. We present our experience of isolated latissimus dorsi (LD) muscle transfer to achieve active external rotation. This is a retrospective review of 24 adult post-traumatic plexopathy patients who underwent isolated latissimus dorsi muscle transfer to restore external rotation of the shoulder between 1997 and 2010. All patients were male with a mean age of 34 years (21 to 57). All the patients underwent isolated LD muscle transfer using a standard technique to correct external rotational deficit. Outcome was assessed for improvement in active external rotation, arc of movement, muscle strength and return to work. The mean improvement in active external rotation from neutral was 24° (10° to 50°). The mean increase in arc of rotation was 52° (38° to 55°). Mean power of the external rotators was 3.5 Medical Research Council (MRC) grades (2 to 5).

A total of 21 patients (88%) were back in work by the time of last follow up. Of these, 13 had returned to their pre-injury occupation. Isolated latissimus dorsi muscle transfer provides a simple and reliable method of restoring useful active external rotation in adults with brachial plexus injuries with internal rotational deformity.

Cite this article: Bone Joint J 2013;95-B:660–3.


The Bone & Joint Journal
Vol. 95-B, Issue 5 | Pages 668 - 672
1 May 2013
Abdel MP Hattrup SJ Sperling JW Cofield RH Kreofsky CR Sanchez-Sotelo J

Instability after arthroplasty of the shoulder is difficult to correct surgically. Soft-tissue procedures and revision surgery using unconstrained anatomical components are associated with a high rate of failure. The purpose of this study was to determine the results of revision of an unstable anatomical shoulder arthroplasty to a reverse design prosthesis. Between 2004 and 2007, 33 unstable anatomical shoulder arthroplasties were revised to a reverse design. The mean age of the patients was 71 years (53 to 86) and their mean follow-up was 42 months (25 to 71). The mean time to revision was 26 months (4 to 164). Pain scores improved significantly (pre-operative visual analogue scale (VAS) of 7.2 (sd 1.6); most recent VAS 2.2 (sd 1.9); p = 0.001). There was a statistically significant increase in mean active forward elevation from 40.2° (sd 27.3) to 97.0° (sd 36.2) (p = 0.001). There was no significant difference in internal (p = 0.93) or external rotation (p = 0.40). Radiological findings included notching in five shoulders (15%) and heterotopic ossification of the inferior capsular region in three (9%). At the last follow-up 31 shoulders (94%) were stable. The remaining two shoulders dislocated at 2.5 weeks and three months post-operatively, respectively. According to the Neer rating system, there were 13 excellent (40%), ten satisfactory (30%) and ten unsatisfactory results (30%). Revision of hemiarthroplasty or anatomical total shoulder replacement for instability using a reverse design prosthesis gives good short-term results.

Cite this article: Bone Joint J 2013;95-B:668–72.


Bone & Joint Research
Vol. 2, Issue 7 | Pages 132 - 139
1 Jul 2013
Ketola S Lehtinen J Rousi T Nissinen M Huhtala H Konttinen YT Arnala I

Objectives

To report the five-year results of a randomised controlled trial examining the effectiveness of arthroscopic acromioplasty in the treatment of stage II shoulder impingement syndrome.

Methods

A total of 140 patients were randomly divided into two groups: 1) supervised exercise programme (n = 70, exercise group); and 2) arthroscopic acromioplasty followed by a similar exercise programme (n = 70, combined treatment group).


The Bone & Joint Journal
Vol. 95-B, Issue 7 | Pages 952 - 959
1 Jul 2013
Cai X Yan S Giddins G

Most patients with a nightstick fracture of the ulna are treated conservatively. Various techniques of immobilisation or early mobilisation have been studied. We performed a systematic review of all published randomised controlled trials and observational studies that have assessed the outcome of these fractures following above- or below-elbow immobilisation, bracing and early mobilisation. We searched multiple electronic databases, related bibliographies and other studies. We included 27 studies comprising 1629 fractures in the final analysis. The data relating to the time to radiological union and the rates of delayed union and nonunion could be pooled and analysed statistically.

We found that early mobilisation produced the shortest radiological time to union (mean 8.0 weeks) and the lowest mean rate of nonunion (0.6%). Fractures treated with above- or below-elbow immobilisation and braces had longer mean radiological times to union (9.2 weeks, 9.2 weeks and 8.7 weeks, respectively) and higher mean rates of nonunion (3.8%, 2.1% and 0.8%, respectively). There was no statistically significant difference in the rate of non- or delayed union between those treated by early mobilisation and the three forms of immobilisation (p = 0.142 to p = 1.000, respectively). All the studies had significant biases, but until a robust randomised controlled trial is undertaken the best advice for the treatment of undisplaced or partially displaced nightstick fractures appears to be early mobilisation, with a removable forearm support for comfort as required.

Cite this article: Bone Joint J 2013;95-B:952–9.


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 6 | Pages 713 - 719
1 Jun 2011
Duckworth AD Ring D McQueen MM

A suspected fracture of the scaphoid remains difficult to manage despite advances in knowledge and imaging methods. Immobilisation and restriction of activities in a young and active patient must be balanced against the risks of nonunion associated with an undiagnosed and undertreated fracture of the scaphoid.

The assessment of diagnostic tests for a suspected fracture of the scaphoid must take into account two important factors. First, the prevalence of true fractures among suspected fractures is low, which greatly reduces the probability that a positive test will correspond with a true fracture, as false positives are nearly as common as true positives. This situation is accounted for by Bayesian statistics. Secondly, there is no agreed reference standard for a true fracture, which necessitates the need for an alternative method of calculating diagnostic performance characteristics, based upon a statistical method which identifies clinical factors tending to associate (latent classes) in patients with a high probability of fracture.

The most successful diagnostic test to date is MRI, but in low-prevalence situations the positive predictive value of MRI is only 88%, and new data have documented the potential for false positive scans. The best strategy for improving the diagnosis of true fractures among suspected fractures of the scaphoid may well be to develop a clinical prediction rule incorporating a set of demographic and clinical factors which together increase the pre-test probability of a fracture of the scaphoid, in addition to developing increasingly sophisticated radiological tests.


The Bone & Joint Journal
Vol. 95-B, Issue 2 | Pages 199 - 205
1 Feb 2013
Robinson PM Wilson J Dalal S Parker RA Norburn P Roy BR

This study reports the clinical and sonographic outcome of arthroscopic rotator cuff repair in patients aged ≥ 70 years and aimed to determine factors associated with re-tear. A total of 69 consecutive repairs were performed in 68 patients with a mean age of 77 years (70 to 86). Constant-Murley scores were collected pre-operatively and at one year post-operatively. The integrity of the repair was assessed using ultrasound. Re-tear was detected in 20 of 62 patients (32%) assessed with ultrasound. Age at operation was significantly associated with re-tear free survival (p = 0.016). The mean pre-operative Constant score was 23 (sd 14), which increased to 58 (sd 20) at one year post-operatively (paired t-test, p < 0.001). Male gender was significantly associated with a higher score at one year (p = 0.019).

We conclude that arthroscopic rotator cuff repair in patients aged ≥ 70 years is a successful procedure. The gender and age of the patient are important factors to consider when planning management.

Cite this article: Bone Joint J 2013;95-B:199–205.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 10 | Pages 1390 - 1392
1 Oct 2012
Bendon CL Giele HP

Injectable collagenase is an alternative to surgical treatment for Dupuytren’s disease. Previous studies have reported on the effectiveness of collagenase in finger contractures. This prospective study reports on the short-term safety and efficacy of collagenase treatment in five thumb and first web space Dupuytren’s contractures. The thumb and first web space contractures were treated with injectable collagenase in four consecutive patients (five hands) with experience of previous surgical digital fasciectomy. The thumb contracture was measured by angle and span in two planes of thumb extension and abduction before injection and after manipulation. Collagenase treatment resulted in release of the contracture with a mean increase in thumb to index angle from 23° (10° to 35°) to 56° (45° to 60°) in extension and from 30° (10° to 50°) to 58° (50° to 65°) in abduction and a mean increase in span from 1.9 cm (1 to 3.5) to 3.9 cm (3 to 5) in extension and from 2.4 cm (1.5 to 3.5) to 3.9 cm (3 to 4.5) in abduction. All patients reported an increased range of movement and function and described collagenase therapy as preferable to surgery. In the short-term collagenase is an effective, well-tolerated and safe alternative to surgery for Dupuytren’s disease of the thumb.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 11 | Pages 1534 - 1539
1 Nov 2012
Karataglis D Papadopoulos P Boutsiadis A Fotiadou A Ditsios K Hatzokos I Christodoulou A

This study evaluates the position of the long head of biceps tendon using ultrasound following simple tenotomy, in patients with arthroscopically repaired rotator cuff tears.

In total, 52 patients with a mean age of 60.7 years (45 to 75) underwent arthroscopic repair of the rotator cuff and simple tenotomy of the long head of biceps tendon. At two years post-operatively, ultrasound revealed that the tendon was inside the bicipital groove in 43 patients (82.7%) and outside in nine (17.3%); in six of these it was lying just outside the groove and in the remaining three (5.8%) it was in a remote position with a positive Popeye Sign. A dynamic ultrasound scan revealed that the tenotomised tendons had adhered to the surrounding tissues (autotenodesis).The initial condition of the tendon influenced its final position (p < 0.0005). The presence of a Popeye sign was statistically influenced by the pre-operative co-existence of supraspinatus and subscapularis tears (p < 0.0001).

It appears that the natural history of the tenotomised long head of biceps tendon is to tenodese itself inside or just outside the bicipital groove, while its pre-operative condition and coexistent subscapularis tears play a significant role in the occurrence of a Popeye sign.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 11 | Pages 1448 - 1454
1 Nov 2012
Ng CY Watts AC

Bone loss involving articular surface is a challenging problem faced by the orthopaedic surgeon. In the hand and wrist, there are articular defects that are amenable to autograft reconstruction when primary fixation is not possible. In this article, the surgical techniques and clinical outcomes of articular reconstructions in the hand and wrist using non-vascularised osteochondral autografts are reviewed.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 9 | Pages 1260 - 1264
1 Sep 2012
Raiss P Lin A Mizuno N Melis B Walch G

A total of 12 epileptic patients (14 shoulders) with recurrent seizures and anterior dislocations of the shoulder underwent a Latarjet procedure and were reviewed at a mean of 8.3 years (1 to 20) post-operatively. Mean forward flexion decreased from 165° (100° to 180°) to 160° (90° to 180°) (p = 0.5) and mean external rotation from 54° (10° to 90°) to 43° (5° to 75°) (p = 0.058). The mean Rowe score was 76 (35 to 100) at the final follow-up. Radiologically, all shoulders showed a glenoid-rim defect and Hill-Sachs lesions pre-operatively. Osteo-arthritic changes of the glenohumeral joint were observed in five shoulders (36%) pre-operatively and in eight shoulders (57%) post-operatively. Re-dislocation during a seizure occurred in six shoulders (43%). Five of these patients underwent revision surgery using a bone buttress from the iliac crest and two of these patients re-dislocated due to a new seizure.

Due to the unacceptably high rate of re-dislocation after surgery in these patients, the most important means of reducing the incidence of further dislocation is the medical management of the seizures. The Latarjet procedure should be reserved for the well-controlled patient with epilepsy who has recurrent anterior dislocation of the shoulder during activities of daily living.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 8 | Pages 1086 - 1089
1 Aug 2012
Magaji SA Singh HP Pandey RK

A total of 92 patients with symptoms for over six months due to subacromial impingement of the shoulder, who were being treated with physiotherapy, were included in this study. While continuing with physiotherapy they waited a further six months for surgery. They were divided into three groups based on the following four clinical and radiological criteria: temporary benefit following steroid injection, pain in the mid-arc of abduction, a consistently positive Hawkins test and radiological evidence of impingement. Group A fulfilled all four criteria, group B three criteria and group C two criteria. A total of nine patients improved while waiting for surgery and were excluded, leaving 83 who underwent arthroscopic subacromial decompression (SAD). The new Oxford shoulder score was recorded pre-operatively and at three and 12 months post-operatively.

A total of 51 patients (group A) had a significant improvement in the mean shoulder score from 18 (13 to 22) pre-operatively to 38 (35 to 42) at three months (p < 0.001). The mean score in this group was significantly better than in group B (21 patients) and C (11 patients) at this time. At one year patients in all groups showed improvement in scores, but patients in group A had a higher mean score (p = 0.01). At one year patients in groups A and B did better than those in group C (p = 0.01).

Arthroscopic SAD is a beneficial intervention in selected patients. The four criteria could help identify patients in whom it is likely to be most effective.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 8 | Pages 1090 - 1096
1 Aug 2012
Mahmoud M El Shafie S Kamal M

Malunion is the most common complication of the distal radius with many modalities of treatment available for such a problem. The use of bone grafting after an osteotomy is still recommended by most authors. We hypothesised that bone grafting is not required; fixing the corrected construct with a volar locked plate helps maintain the alignment, while metaphyseal defect fills by itself. Prospectively, we performed the procedure on 30 malunited dorsally-angulated radii using fixed angle volar locked plates without bone grafting. At the final follow-up, 22 wrists were available. Radiological evidence of union, correction of the deformity, clinical and functional improvement was achieved in all cases. Without the use of bone grafting, corrective open wedge osteotomy fixed by a volar locked plate provides a high rate of union and satisfactory functional outcomes.


Bone & Joint Research
Vol. 1, Issue 9 | Pages 210 - 217
1 Sep 2012
Walton JR Murrell GAC

Objectives

The aim of this study was to determine whether there is any significant difference in temporal measurements of pain, function and rates of re-tear for arthroscopic rotator cuff repair (RCR) patients compared with those patients undergoing open RCR.

Methods

This study compared questionnaire- and clinical examination-based outcomes over two years or longer for two series of patients who met the inclusion criteria: 200 open RCR and 200 arthroscopic RCR patients. All surgery was performed by a single surgeon.


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 6 | Pages 811 - 816
1 Jun 2010
Robinson CM Akhtar MA Jenkins PJ Sharpe T Ray A Olabi B

Displaced fractures of the lateral end of the clavicle in young patients have a high incidence of nonunion and a poor functional outcome after conservative management. Operative treatment is therefore usually recommended. However, current techniques may be associated with complications which require removal of the fixation device. We have evaluated the functional and radiological outcomes using a novel technique of open reduction and internal fixation. A series of 16 patients under 60 years of age with displaced fractures of the lateral end were treated by open reduction and fixation using a twin coracoclavicular endobutton technique. They were followed up for the first year after their injury.

At one year the mean Constant score was 87.1 and the median Disabilities of the Arm, Shoulder and Hand score was 3.3. All fractures had united, except in one patient who developed an asymptomatic fibrous union. One patient had post-traumatic stiffness of the shoulder, which resolved with physiotherapy. None required re-operation.

This technique produces good functional and radiological outcomes with a low prevalence of complications and routine implant removal is not necessary.


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 7 | Pages 942 - 948
1 Jul 2011
Chaudhury S Holland C Vollrath F Carr AJ

This study reports the application of a novel method for quantitatively determining differences in the mechanical properties of healthy and torn rotator cuff tissues. In order to overcome problems of stress risers at the grip-tendon interface that can obscure mechanical measurements of small tendons, we conducted our investigation using dynamic shear analysis.

Rotator cuff tendon specimens were obtained from 100 patients during shoulder surgery. They included 82 differently sized tears and 18 matched controls. We subjected biopsy samples of 3 mm in diameter to oscillatory deformation under compression using dynamic shear analysis. The storage modulus (G’) was calculated as an indicator of mechanical integrity.

Normal tendons had a significantly higher storage modulus than torn tendons, indicating that torn tendons are mechanically weaker than normal tendons (p = 0.003). Normal tendons had a significantly higher mean shear modulus than tendons with massive tears (p < 0.01).

Dynamic shear analysis allows the determination of shear mechanical properties of small tissue specimens obtained intra-operatively that could not be studied by conventional methods of tensile testing. These methods could be employed to investigate other musculoskeletal tissues. This pilot study provides some insight into mechanisms that might contribute to the failure of repair surgery, and with future application could help direct the most appropriate treatment for specific rotator cuff tears.


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 10 | Pages 1397 - 1402
1 Oct 2010
Nada AN Debnath UK Robinson DA Jordan C

We describe the clinical outcome of a technique of surgical augmentation of chronic massive tears of the rotator cuff using a polyester ligament (Dacron) in 21 symptomatic patients (14 men, seven women) with a mean age of 66.5 years (55.0 to 85.0). All patients had MRI and arthroscopic evidence of chronic massive tears. The clinical outcome was assessed using the Constant and Murley and patient satisfaction scores at a mean follow-up of 36 months (30 to 46).

The polyester ligament (500 mm × 10 mm) was passed into the joint via the portal of Neviaser, medial to the tear through healthy cuff. The two ends of the ligament holding the cuff were passed through tunnels made in the proximal humerus at the footprint of the insertion of the cuff. The ligament was tied with a triple knot over the humeral cortex.

All the patients remained free from pain (p < 0.001) with improvement in function (p < 0.001) and range of movement (p < 0.001). The mean pre-operative and post-operative Constant scores were 46.7 (39.0 to 61.0) and 85.4 (52.0 to 96.0), respectively (p < 0.001). The mean patient satisfaction score was 90%. There were two failures, one due to a ruptured ligament after one year and the other due to deep-seated infection. The MR scan at the final follow-up confirmed intact and thickened bands in 15 of 17 patients.

This technique of augmentation gives consistent relief from pain with improved shoulder movement in patients with symptomatic massive tears of the rotator cuff.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 6 | Pages 799 - 804
1 Jun 2012
Hems TEJ Mahmood F

We reviewed 101 patients with injuries of the terminal branches of the infraclavicular brachial plexus sustained between 1997 and 2009. Four patterns of injury were identified: 1) anterior glenohumeral dislocation (n = 55), in which the axillary and ulnar nerves were most commonly injured, but the axillary nerve was ruptured in only two patients (3.6%); 2) axillary nerve injury, with or without injury to other nerves, in the absence of dislocation of the shoulder (n = 20): these had a similar pattern of nerve involvement to those with a known dislocation, but the axillary nerve was ruptured in 14 patients (70%); 3) displaced proximal humeral fracture (n = 15), in which nerve injury resulted from medial displacement of the humeral shaft: the fracture was surgically reduced in 13 patients; and 4) hyperextension of the arm (n = 11): these were characterised by disruption of the musculocutaneous nerve. There was variable involvement of the median and radial nerves with the ulnar nerve being least affected.

Surgical intervention is not needed in most cases of infraclavicular injury associated with dislocation of the shoulder. Early exploration of the nerves should be considered in patients with an axillary nerve palsy without dislocation of the shoulder and for musculocutaneous nerve palsy with median and/or radial nerve palsy. Urgent operation is needed in cases of nerve injury resulting from fracture of the humeral neck to relieve pressure on nerves.


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 8 | Pages 1107 - 1111
1 Aug 2010
Rees JL Dawson J Hand GCR Cooper C Judge A Price AJ Beard DJ Carr AJ

We have compared the outcome of hemiarthroplasty of the shoulder in three distinct diagnostic groups, using survival analysis as used by the United Kingdom national joint registers, patient-reported outcome measures (PROMs) as recommended by Darzi in the 2008 NHS review, and transition and satisfaction questions.

A total of 72 hemiarthroplasties, 19 for primary osteoarthritis (OA) with an intact rotator cuff, 22 for OA with a torn rotator cuff, and 31 for rheumatoid arthritis (RA), were followed up for between three and eight years. All the patients survived, with no revisions or dislocations and no significant radiological evidence of loosening. The mean new Oxford shoulder score (minimum/worst 0, maximum/best 48) improved significantly for all groups (p < 0.001), in the OA group with an intact rotator cuff from 21.4 to 38.8 (effect size 2.9), in the OA group with a torn rotator cuff from 13.3 to 27.2 (effect size 2.1) and in the RA group from 13.7 to 28.0 (effect size 3.1). By this assessment, and for the survival analysis, there was no significant difference between the groups. However, when ratings using the patient satisfaction questions were analysed, eight (29.6%) of the RA group were ‘disappointed’, compared with one (9.1%) of the OA group with cuff intact and one (7.7%) of the OA group with cuff torn. All patients in the OA group with cuff torn indicated that they would undergo the operation again, compared to ten (90.9%) in the OA group with cuff intact and 20 (76.9%) in the RA group.

The use of revision rates alone does not fully represent outcome after hemiarthroplasty of the shoulder. Data from PROMs provides more information about change in pain and the ability to undertake activities and perform tasks. The additional use of satisfaction ratings shows that both the rates of revision surgery and PROMs need careful interpretation in the context of patient expectations.


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 1 | Pages 62 - 67
1 Jan 2011
Camp SJ Birch R

The integrity of the spinal accessory nerve is fundamental to thoracoscapular function and essential for scapulohumeral rhythm. This nerve is vulnerable along its superficial course. This study assessed the delay in diagnosis and referral for management of damage to this nerve, clarified its anatomical course and function, and documented the results of repair. From examination of our records, 111 patients with lesions of the spinal accessory nerve were treated between 1984 and 2007. In 89 patients (80.2%) the damage was iatropathic. Recognition and referral were seldom made by the surgeon responsible for the injury, leading to a marked delay in instituting treatment. Most referrals were made for painful loss of shoulder function. The clinical diagnosis is straightforward. There is a characteristic downward and lateral displacement of the scapula, with narrowing of the inferior scapulohumeral angle and loss of function, with pain commonly present. In all, 80 nerves were explored and 65 were repaired. The course of the spinal accessory nerve in relation to the sternocleidomastoid muscle was constant, with branches from the cervical plexus rarely conveying motor fibres. Damage to the nerve was predominantly posterior to this muscle.

Despite the delay, the results of repair were surprising, with early relief of pain, implying a neuropathic source, which preceded generally good recovery of muscle function.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 1 | Pages 80 - 85
1 Jan 2012
Malone AA Sanchez JS Adams R Morrey B

We report the effectiveness of revision of total elbow replacement by re-cementing. Between 1982 and 2004, 53 elbows in 52 patients were treated with re-cementing of a total elbow replacement into part or all of the existing cement mantle or into the debrided host-bone interface, without the use of structural bone augmentation or a custom prosthesis. The original implant revision was still in situ and functional in 42 of 53 elbows (79%) at a mean of 94.5 months (26 to 266) after surgery. In 31 of these 42 elbows (74%) the Mayo Elbow Performance Score was good or excellent. Overall, of the 53 elbows, 18 (34%) required re-operation, ten (19%) for loosening. A classification system was developed to identify those not suitable for revision by this technique, and using this we have showed that successful re-implantation is statistically correlated to properly addressing the bone deficiency for both the humeral (p = 0.005) and the ulnar (p = 0.039) components.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 1 | Pages 16 - 22
1 Jan 2012
Popovic D King GJW

In light of the growing number of elderly osteopenic patients with distal humeral fractures, we discuss the history of their management and current trends. Under most circumstances operative fixation and early mobilisation is the treatment of choice, as it gives the best results. The relative indications for and results of total elbow replacement versus internal fixation are discussed.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 1 | Pages 1 - 9
1 Jan 2012
Robinson CM Seah KTM Chee YH Hindle P Murray IR

Frozen shoulder is commonly encountered in general orthopaedic practice. It may arise spontaneously without an obvious predisposing cause, or be associated with a variety of local or systemic disorders. Diagnosis is based upon the recognition of the characteristic features of the pain, and selective limitation of passive external rotation. The macroscopic and histological features of the capsular contracture are well-defined, but the underlying pathological processes remain poorly understood. It may cause protracted disability, and imposes a considerable burden on health service resources. Most patients are still managed by physiotherapy in primary care, and only the more refractory cases are referred for specialist intervention. Targeted therapy is not possible and treatment remains predominantly symptomatic. However, over the last ten years, more active interventions that may shorten the clinical course, such as capsular distension arthrography and arthroscopic capsular release, have become more popular.

This review describes the clinical and pathological features of frozen shoulder. We also outline the current treatment options, review the published results and present our own treatment algorithm.


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 8 | Pages 1112 - 1117
1 Aug 2010
Clement ND Hallett A MacDonald D Howie C McBirnie J

We compared the outcome of arthroscopic repair of the rotator cuff in 32 diabetic patients with the outcome in 32 non-diabetic patients matched for age, gender, size of tear and comorbidities. The Constant-Murley score improved from a mean of 49.2 (24 to 80) pre-operatively to 60.8 (34 to 95) post-operatively (p = 0.0006) in the diabetic patients, and from 46.4 (23 to 90) pre-operatively to 65.2 (25 to 100) post-operatively (p = 0.0003) in the non-diabetic patients at six months. This was significantly greater (p = 0.0002) in non-diabetic patients (18.8) than in diabetics (11.6). There was no significant change in the mean mental component of the Short-Form 12, but the mean physical component increased from 35 to 41 in non-diabetics (p = 0.0001), and from 37 to 39 (p = 0.15) in diabetics. These trends were observed at one year.

Patients with diabetes showed improvement of pain and function following arthroscopic rotator cuff repair in the short term, but less than their non-diabetic counterparts.


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 7 | Pages 932 - 936
1 Jul 2011
Mahmoud M Koptan W

Ununited fractures of the scaphoid with extensive bone resorption are usually treated by bone grafting and internal fixation, using either an open or a minimally invasive technique. We studied the feasibility of percutaneous fixation without bone grafting in a consecutive series of 27 patients with established nonunion of an undisplaced fracture of the scaphoid and extensive local resorption of bone. They were treated by a single surgeon with rigid fixation alone, using a headless cannulated screw inserted through a volar percutaneous technique. Clinical examination, standard radiographs and CT confirmed that the fracture had united in all patients at a mean of 11.6 weeks (8 to 16), and that their functional scores had improved.

We concluded that extensive resorption at the fracture site is not an absolute indication for bone grafting, and that percutaneous fixation alone will eventually produce healing of ununited undisplaced fractures of the scaphoid regardless of the size of the gap.


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 2 | Pages 223 - 228
1 Feb 2011
Neumann M Nyffeler R Beck M

Mason type III fractures of the radial head are treated by open reduction and internal fixation, resection or prosthetic joint replacement. When internal fixation is performed, fixation of the radial head to the shaft is difficult and implant-related complications are common. Furthermore, problems of devascularisation of the radial head can result from fixation of the plate to the radial neck.

In a small retrospective study, the treatment of Mason type III fractures with fixation of the radial neck in 13 cases (group 2) was compared with 12 cases where no fixation was performed (group 1). The mean clinical and radiological follow-up was four years (1 to 9). The Broberg-Morrey index showed excellent results in both groups. Degenerative radiological changes were seen more frequently in group 2, and removal of the implant was necessary in seven of 13 cases.

Post-operative evaluation of these two different techniques revealed similar ranges of movement and functional scores. We propose that anatomical reconstruction of the radial head without metalwork fixation to the neck is preferable, and the outcome is the same as that achieved with the conventional technique. In addition degenerative changes of the elbow joint may develop less frequently, and implant removal is not necessary.


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 7 | Pages 899 - 905
1 Jul 2008
Dias JJ Dhukaram V Abhinav A Bhowal B Wildin CJ

We report the outcome at a mean of 93 months (73 to 110) of 71 patients with an acute fracture of the scaphoid who were randomised to Herbert screw fixation (35) or below-elbow plaster cast immobilisation (36). These 71 patients represent the majority of a randomised series of 88 patients whose short-term outcome has previously been reported. Those patients available for later review were similar in age, gender and hand dominance.

There was no statistical difference in symptoms and disability as assessed by the mean Patient Evaluation Measure (p = 0.4), or mean Patient-Rated Wrist Evaluation (p = 0.9), the mean range of movement of the wrist (p = 0.4), mean grip strength (p = 0.8), or mean pinch strength (p = 0.4).

Radiographs were available from the final review for 59 patients. Osteoarthritic changes were seen in the scaphotrapezial and radioscaphoid joints in eight (13.5%) and six patients (10.2%), respectively. Three patients had asymptomatic lucency surrounding the screw. One non-operatively treated patient developed nonunion with avascular necrosis. In five patients who were treated non-operatively (16%) there was an abnormal scapholunate angle ( > 60°), but in four of these patients this finding was asymptomatic.

No medium-term difference in function or radiological outcome was identified between the two treatment groups.


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 6 | Pages 745 - 750
1 Jun 2008
Millar NL Murrell GAC

We identified ten patients who underwent arthroscopic revision of anterior shoulder stabilisation between 1999 and 2005. Their results were compared with 15 patients, matched for age and gender, who had a primary arthroscopic stabilisation during the same period.

At a mean follow-up of 37 and 36 months, respectively, the scores for pain and shoulder function improved significantly between the pre-operative and follow-up visits in both groups (p = 0.002), with no significant difference between them (p = 0.4). The UCLA and Rowe shoulder scores improved significantly (p = 0.004 and p = 0.002, respectively), with no statistically significant differences between groups (p = 0.6). Kaplan-Meier analysis for time to recurrent instability showed no differences between the groups (p = 0.2).

These results suggest that arthroscopic revision anterior shoulder stabilisation is as reliable as primary arthroscopic stabilisation for patients who have had previous open surgery for recurrent anterior instability.


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 1 | Pages 61 - 65
1 Jan 2008
O’Donnell TMP McKenna JV Kenny P Keogh P O’Flanagan SJ

Antegrade intramedullary nailing of fractures of the shaft of the humerus is reported to cause impairment of the shoulder joint. We have reviewed 33 patients with such fractures to assess how many had injuries to the ipsilateral shoulder. All had an MR scan of the shoulder within 11 days of injury. The unaffected shoulder was also scanned as a control. There was evidence of abnormality in 21 of the shoulders (63.6%) on the injured side; ten had bursitis of the subacromial space, five evidence of a partial tear of the rotator cuff, one a complete rupture of the supraspinatus tendon, four inflammatory changes in the acromioclavicular joint and one a fracture of the coracoid process. These injuries may contribute to pain and dysfunction of the shoulder following treatment, and their presence indicates that antegrade nailing is only partly, if at all, responsible for these symptoms.


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 10 | Pages 1410 - 1415
1 Oct 2010
Castagna A Randelli M Garofalo R Maradei L Giardella A Borroni M

Total shoulder replacement is a successful procedure for degenerative or some inflammatory diseases of the shoulder. However, fixation of the glenoid seems to be the main weakness with a high rate of loosening. The results using all-polyethylene components have been better than those using metal-backed components. We describe our experience with 35 consecutive total shoulder replacements using a new metal-backed glenoid component with a mean follow-up of 75.4 months (48 to 154).

Our implant differs from others because of its mechanism of fixation. It has a convex metal-backed bone interface and the main stabilising factor is a large hollow central peg. The patients were evaulated with standard radiographs and with the Constant Score, the Simple Shoulder Test and a visual analogue scale. All the scores improved and there was no loosening, no polyethylene-glenoid disassembly and no other implant-related complications.

We conclude that a metal-backed glenoid component is a good option in total shoulder replacement with no worse results than of those using a cemented all-polyethylene prosthesis.


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 10 | Pages 1403 - 1409
1 Oct 2010
Pape G Zeifang F Bruckner T Raiss P Rickert M Loew M

Fractures of the proximal humerus can lead to malalignment of the humeral head, necrosis and post-traumatic osteoarthritis. In such cases surface replacement might be a promising option.

A total of 28 shoulders with glenohumeral arthritis subsequent to a fracture underwent surface replacement arthroplasty of the humeral head in patients with a mean age of 60 years (35 to 83). On the basis of the inclination of the impacted head, post-traumatic arthritis was divided into three types: type 1, an impacted fracture of the head in an anatomical position (seven cases); type 2, a valgus impacted fracture (13 cases); type 3, a varus impacted fracture (eight cases). The outcome was measured by means of the Constant score.

According to the Boileau classification of the sequelae of fractures of the proximal humerus, all 28 patients had a final result of intra-capsular category 1. The mean Constant score for the 28 shoulders increased from 23.2 points (2 to 45) pre-operatively to 55.1 points (20 to 89) at a mean of 31 months (24 to 66) post-operatively. Valgus impacted fractures had significantly better results (p < 0.039).

Surface replacement arthroplasty can provide good results for patients with post-traumatic osteoarthritis of the shoulder. Their use avoids post-operative complications of the humeral shaft, such as peri-prosthetic fractures. Further surgery can be undertaken more easily as the bone stock is preserved.


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 5 | Pages 651 - 655
1 May 2010
Meuffels DE Schuit H van Biezen FC Reijman M Verhaar JAN

We present the long-term outcome, at a median of 18 years (12.8 to 23.5) of open posterior bone block stabilisation for recurrent posterior instability of the shoulder in a heterogenous group of 11 patients previously reported on in 2001 at a median follow-up of six years.

We found that five (45%) would not have chosen the operation again, and that four (36%) had further posterior dislocation. Clinical outcome was significantly worse after 18 years than after six years of follow-up (median Rowe score of 60 versus 90 (p = 0.027)). The median Western Ontario Shoulder Index was 60% (37% to 100%) at 18 years’ follow-up, which is a moderate score. At the time of surgery four (36%) had glenohumeral radiological osteoarthritis, which was present in all after 18 years.

This study showed poor long-term results of the posterior bone block procedure for posterior instability and a high rate of glenohumeral osteoarthritis although three patients with post-traumatic instability were pleased with the result of their operations.


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 5 | Pages 656 - 660
1 May 2010
Ikävalko M Tiihonen R Skyttä ET Belt EA

Between 1982 and 1997, 403 consecutive patients (522 elbows) with rheumatoid arthritis underwent Souter-Strathclyde total elbow replacement. By the end of 2007, there had been 66 revisions for aseptic loosening in 60 patients. The mean time of follow-up was 10.6 years (0 to 25) The survival rates at five-, ten, 15 and 19 years were 96% (95%, confidence interval (CI) 95 to 98), 89% (95% CI 86 to 92), 83% (95% CI 78 to 87), and 77% (95% CI 69 to 85), respectively. The small and medium-sized short-stemmed primary humeral components had a 5.6-fold and 3.6-fold risk of revision for aseptic loosening respectively, compared to the medium-sized long-stemmed component. The small and medium-sized all-polyethylene ulnar components had respectively a 28.2-fold and 8.4-fold risk of revision for aseptic loosening, compared to the metal-backed ulnar components.

The use of retentive ulnar components was not associated with an increased risk of aseptic loosening compared to non-retentive implants.


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 6 | Pages 823 - 827
1 Jun 2010
Gong HS Chung MS Kang ES Oh JH Lee YH Baek GH

The outcome of surgery in patients with medial epicondylitis of the elbow is less favourable in those with co-existent symptoms from the ulnar nerve. We wanted to know whether we could successfully treat such patients by using musculofascial lengthening of the flexor-pronator origin with simultaneous deep transposition of the ulnar nerve. We retrospectively reviewed 19 patients who were treated in this way. Seven had grade I and 12 had grade IIa ulnar neuropathy. At a mean follow-up of 38 months (24 to 48), the mean visual analogue scale pain scores improved from 3.7 to 0.3 at rest, from 6.6 to 2.1 with activities of daily living, and from 7.9 to 2.3 at work or sports, and the mean disabilities of the arm, shoulder and hand scores improved from 42.2 to 23.5.

These results suggest that this technique can be effective in treating patients with medial epicondylitis and coexistent ulnar nerve symptoms.


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 7 | Pages 889 - 892
1 Jul 2008
Al-Shawi A Badge R Bunker T

We have examined the accuracy of 143 consecutive ultrasound scans of patients who subsequently underwent shoulder arthroscopy for rotator-cuff disease. All the scans and subsequent surgery were performed by an orthopaedic surgeon using a portable ultrasound scanner in a one-stop clinic. There were 78 full thickness tears which we confirmed by surgery or MRI. Three moderate-size tears were assessed as partial-thickness at ultrasound scan (false negative) giving a sensitivity of 96.2%. One partially torn and two intact cuffs were over-diagnosed as small full-thickness tears by ultrasound scan (false positive) giving a specificity of 95.4%. This gave a positive predictive value of 96.2% and a negative predictive value of 95.4%. Estimation of tear size was more accurate for large and massive tears at 96.5% than for moderate (88.8%) and small tears (91.6%). These results are equivalent to those obtained by several studies undertaken by experienced radiologists.

We conclude that ultrasound imaging of the shoulder performed by a sufficiently-trained orthopaedic surgeon is a reliable time-saving practice to identify rotator-cuff integrity.


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 7 | Pages 915 - 917
1 Jul 2009
Gwilym SE Watkins B Cooper CD Harvie P Auplish S Pollard TCB Rees JL Carr AJ

The aim of this study was to investigate genetic influences on the development and progression of tears of the rotator cuff. From a group of siblings of patients with a tear of the rotator cuff and of controls studied five years earlier, we determined the prevalence of tears of the rotator cuff with and without associated symptoms using ultrasound and the Oxford Shoulder Score.

In the five years since the previous assessment, three of 62 (4.8%) of the sibling group and one of the 68 (1.5%) controls had undergone shoulder surgery. These subjects were excluded from the follow-up.

Full-thickness tears were found in 39 of 62 (62.9%) siblings and in 15 of 68 (22.1%) controls (p = 0.0001). The relative risk of full-thickness tears in siblings as opposed to controls was 2.85 (95% confidence interval (CI) 1.75 to 4.64), compared to 2.42 (95% CI 1.77 to 3.31) five years earlier. Full-thickness tears associated with pain were found in 30 of 39 (76.9%) tears in the siblings and in eight of 15 (53.3%) tears in the controls (p = 0.045). The relative risk of pain associated with a full-thickness tear in the siblings as opposed to the controls was 1.44 (95% CI 2.04 to 8.28) (p = 0.045).

In the siblings group ten of 62 (16.1%) had progressed in terms of tear size or development compared to one of 68 (1.5%) in the control group which had increased in size.

Full-thickness rotator cuff tears in siblings are significantly more likely to progress over a period of five years than in a control population. This implies that genetic factors have a role, not only in the development but also in the progression of full-thickness tears of the rotator cuff.


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 12 | Pages 1587 - 1593
1 Dec 2009
Oh JH Kim SH Kim JH Shin YH Yoon JP Oh CH

This study examined the role of vitamin D as a factor accounting for fatty degeneration and muscle function in the rotator cuff. There were 366 patients with disorders of the shoulder. A total of 228 patients had a full-thickness tear (group 1) and 138 patients had no tear (group 2). All underwent magnetic resonance arthrography and an isokinetic muscle performance test. The serum concentrations of vitamin D (25(OH)D3) were measured.

In general, a lower serum level of vitamin D was related to higher fatty degeneration in the muscles of the cuff. Spearman’s correlation coefficients were 0.173 (p = 0.001), −0.181 (p = 0.001), and −0.117 (p = 0.026) for supraspinatus, infraspinatus and subscapularis, respectively. In group 1, multivariate linear regression analysis revealed that the serum level of vitamin D was an independent variable for fatty degeneration of the supraspinatus and infraspinatus.

The serum vitamin D level has a significant negative correlation with the fatty degeneration of the cuff muscle and a positive correlation with isokinetic muscle torque.


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 10 | Pages 1326 - 1334
1 Oct 2009
Ketola S Lehtinen J Arnala I Nissinen M Westenius H Sintonen H Aronen P Konttinen YT Malmivaara A Rousi T

We report a randomised controlled trial to examine the effectiveness and cost-effectiveness of arthroscopic acromioplasty in the treatment of stage II shoulder impingement syndrome. A total of 140 patients were randomly divided into two treatment groups: supervised exercise programme (n = 70, exercise group) and arthroscopic acromioplasty followed by a similar exercise programme (n = 70, combined treatment group). The main outcome measure was self-reported pain on a visual analogue scale of 0 to 10 at 24 months, measured on the 134 patients (66 in the exercise group and 68 in the combined treatment group) for whom endpoint data were available.

An intention-to-treat analysis disclosed an improvement in both groups but without statistically significant difference in outcome between the groups (p = 0.65). The combined treatment was considerably more costly.

Arthroscopic acromioplasty provides no clinically important effects over a structured and supervised exercise programme alone in terms of subjective outcome or cost-effectiveness when measured at 24 months. Structured exercise treatment should be the basis for treatment of shoulder impingement syndrome, with operative treatment offered judiciously until its true merit is proven.


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 3 | Pages 374 - 378
1 Mar 2009
Ullah AS Dias JJ Bhowal B

We randomised 79 patients (84 hands, 90 fingers) with Dupuytren’s contracture of the proximal interphalangeal joint to have either a ‘firebreak’ skin graft (39 patients, 41 hands, 44 fingers) or a fasciectomy (40 patients, 43 hands, 46 fingers) if, after full correction, the skin over the proximal phalanx could be easily closed by a Z-plasty. Patients were reviewed after three, six, 12, 24 and 36 months to note any complications, the range of movement and recurrence. Both groups were similar in regard to age, gender and factors considered to influence the outcome such as bilateral disease, family history, the presence of diabetes, smoking and alcohol intake.

The degree of contracture of the metacarpophalangeal and interphalangeal joints of the operated fingers was similar in the two groups and both were comparable in terms of grip strength, range of movement and disability at each follow-up. The recurrence rate was 12.2%.

We did not identify any improvement in correction or recurrence of contracture after firebreak dermofasciectomy up to three years after surgery.


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 4 | Pages 511 - 516
1 Apr 2009
Yam A Fullilove S Sinisi M Fox M

We reviewed 42 consecutive children with a supination deformity of the forearm complicating severe birth lesions of the brachial plexus.

The overall incidence over the study period was 6.9% (48 of 696). It was absent in those in Narakas group I (27.6) and occurred in 5.7% of group II (13 of 229), 9.6% of group III (11 of 114) and 23.4% of group IV (18 of 77).

Concurrent deformities at the shoulder, elbow, wrist and hand were always present because of muscular imbalance from poor recovery of C5 and C7, inconsistent recovery of C8 and T1 and good recovery of C6. Early surgical correction improved the function of the upper limb and hand, but there was a tendency to recurrence. Pronation osteotomy placed the hand in a functional position, and increased the arc of rotation of the forearm. The supination deformity recurred in 40% (17 of 42) of those treated by pronation osteotomy alone, probably because of remodelling of the growing bone.

Children should be followed up until skeletal maturity, and the parents counselled on the likelihood of multiple operations.


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 2 | Pages 196 - 200
1 Feb 2009
Moosmayer S Smith H Tariq R Larmo A

We undertook clinical and ultrasonographic examination of the shoulders of 420 asymptomatic volunteers aged between 50 and 79 years. MRI was performed in selected cases. Full-thickness tears of the rotator cuff were detected in 32 subjects (7.6%). The prevalence increased with age as follows: 50 to 59 years, 2.1%; 60 to 69 years, 5.7%; and 70 to 79 years, 15%. The mean size of the tear was less than 3 cm and tear localisation was limited to the supraspinatus tendon in most cases (78%). The strength of flexion was reduced significantly in the group with tears (p = 0.01).

Asymptomatic tears of the rotator cuff should be regarded as part of the normal ageing process in the elderly but may be less common than hitherto believed.


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 5 | Pages 619 - 626
1 May 2009
Herrera DA Anavian J Tarkin IS Armitage BA Schroder LK Cole PA

Between 1998 and 2007, 22 patients with fractures of the scapula had operative treatment more than three weeks after injury. The indications for operation included displaced intra-articular fractures, medialisation of the glenohumeral joint, angular deformity, or displaced double lesions of the superior shoulder suspensory complex.

Radiological and functional outcomes were obtained for 16 of 22 patients. Disabilities of the Arm, Shoulder, Hand (DASH) and Short form-36 scores were collected for 14 patients who were operated on after March 2002. The mean delay from injury to surgery was 30 days (21 to 57). The mean follow-up was for 27 months (12 to 72). At the last review the mean DASH score was 14 (0 to 41). Of the 16 patients with follow-up, 13 returned to their previous employment and recreational activities without restrictions. No wound complications, infection or nonunion occurred.

Malunion of the scapula can be prevented by surgical treatment of fractures in patients with delayed presentation. Surgery is safe, effective, and gives acceptable functional results.


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 1 | Pages 75 - 81
1 Jan 2009
Cil A Veillette CJH Sanchez-Sotelo J Sperling JW Schleck C Cofield RH

Between 1976 and 2004, 38 revision arthroplasties (35 patients) were performed for aseptic loosening of the humeral component. The mean interval from primary arthroplasty to revision was 7.1 years (0.4 to 16.6). A total of 35 shoulders (32 patients) were available for review at a mean follow-up of seven years (2 to 19.3).

Pre-operatively, 34 patients (97%) had moderate or severe pain; at final follow-up, 29 (83%) had no or only mild pain (p < 0.0001). The mean active abduction improved from 88° to 107° (p < 0.01); and the mean external rotation from 37° to 46° (p = 0.27). Excellent or satisfactory results were achieved in 25 patients (71%) according to the modified Neer rating system. Humeral components were cemented in 29, with ingrowth implants used in nine cases. There were 19 of standard length and 17 were longer (two were custom replacements and are not included). Bone grafting was required for defects in 11 humeri. Only two glenoid components were left unrevised. Intra-operative complications included cement extrusion in eight cases, fracture of the shaft of the humerus is two and of the tuberosity in four. There were four re-operations, one for recurrent humeral loosening, with 89% survival free of re-operations at ten years.

Revision surgery for aseptic loosening of the humeral component provides reliable pain relief and modest improvement of movement, although there is a substantial risk of intra-operative complications. Revision to a total shoulder replacement gives better results than to a hemiarthroplasty.


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 11 | Pages 1462 - 1467
1 Nov 2008
Patel RV Apostle K Leith JM Regan WD

We have investigated the outcome of arthroscopic revision surgery for recurrent instability of the shoulder after failed primary anterior stabilisation. We identified 40 patients with failed primary open or arthroscopic anterior stabilisation of the shoulder who had been treated by revision arthroscopic capsulolabral reconstruction and followed up for a mean of 36 months (12 to 87). There were 34 men and six women with a mean age of 33.1 years (15 to 48). Details of the patients, the technique of the primary procedure, the operative findings at revision and the clinical outcome were evaluated by reviewing the medical records, physical examination and the use of the Western Ontario shoulder instability index score, the American Shoulder and Elbow Surgeons score and the health status questionnaire 12.

Recurrent instability persisted in four patients after the revision arthroscopic procedure. At the final follow-up, the mean American Shoulder and Elbow Surgeons score was 81.1 (17.5 to 99.5) and the mean Western Ontario shoulder instability index score was 68.2 (20 to 98.2). Quality-of-life scoring showed good to excellent results in most patients.

Arthroscopic revision capsulolabral reconstruction can provide a satisfactory outcome in selected patients for recurrent instability of the shoulder provided that no large Hill-Sachs lesion is present.


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 9 | Pages 1205 - 1209
1 Sep 2008
Beeres FJP Rhemrev SJ den Hollander P Kingma LM Meylaerts SAG le Cessie S Bartlema KA Hamming JF Hogervorst M

We evaluated 100 consecutive patients with a suspected scaphoid fracture but without evidence of a fracture on plain radiographs using MRI within 24 hours of injury, and bone scintigraphy three to five days after injury. The reference standard for a true radiologically-occult scaphoid fracture was either a diagnosis of fracture on both MRI and bone scintigraphy, or, in the case of discrepancy, clinical and/or radiological evidence of a fracture.

MRI revealed 16 scaphoid and 24 other fractures. Bone scintigraphy showed 28 scaphoid and 40 other fractures. According to the reference standard there were 20 scaphoid fractures. MRI was falsely negative for scaphoid fracture in four patients and bone scintigraphy falsely positive in eight. MRI had a sensitivity of 80% and a specificity of 100%. Bone scintigraphy had a sensitivity of 100% and a specificity of 90%.

This study did not confirm that early, short-sequence MRI was superior to bone scintigraphy for the diagnosis of a suspected scaphoid fracture. Bone scintigraphy remains a highly sensitive and reasonably specific investigation for the diagnosis of an occult scaphoid fracture.


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 7 | Pages 893 - 898
1 Jul 2008
Levy O Relwani J Zaman T Even T Venkateswaran B Copeland S

The aim of this study was to define the microcirculation of the normal rotator cuff during arthroscopic surgery and investigate whether it is altered in diseased cuff tissue.

Blood flow was measured intra-operatively by laser Doppler flowmetry. We investigated six different zones of each rotator cuff during the arthroscopic examination of 56 consecutive patients undergoing investigation for impingement, cuff tears or instability; there were 336 measurements overall.

The mean laser Doppler flowmetry flux was significantly higher at the edges of the tear in torn cuffs (43.1, 95% confidence interval (CI) 37.8 to 48.4) compared with normal cuffs (32.8, 95% CI 27.4 to 38.1; p = 0.0089). It was significantly lower across all anatomical locations in cuffs with impingement (25.4, 95% CI 22.4 to 28.5) compared with normal cuffs (p = 0.0196), and significantly lower in cuffs with impingement compared with torn cuffs (p < 0.0001).

Laser Doppler flowmetry analysis of the rotator cuff blood supply indicated a significant difference between the vascularity of the normal and the pathological rotator cuff. We were unable to demonstrate a functional hypoperfusion area or so-called ‘critical zone’ in the normal cuff. The measured flux decreases with advancing impingement, but there is a substantial increase at the edges of rotator cuff tears. This might reflect an attempt at repair.