Advertisement for orthosearch.org.uk
Results 1 - 100 of 180
Results per page:
The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 5 | Pages 651 - 655
1 May 2010
Meuffels DE Schuit H van Biezen FC Reijman M Verhaar JAN

We present the long-term outcome, at a median of 18 years (12.8 to 23.5) of open posterior bone block stabilisation for recurrent posterior instability of the shoulder in a heterogenous group of 11 patients previously reported on in 2001 at a median follow-up of six years. We found that five (45%) would not have chosen the operation again, and that four (36%) had further posterior dislocation. Clinical outcome was significantly worse after 18 years than after six years of follow-up (median Rowe score of 60 versus 90 (p = 0.027)). The median Western Ontario Shoulder Index was 60% (37% to 100%) at 18 years’ follow-up, which is a moderate score. At the time of surgery four (36%) had glenohumeral radiological osteoarthritis, which was present in all after 18 years. This study showed poor long-term results of the posterior bone block procedure for posterior instability and a high rate of glenohumeral osteoarthritis although three patients with post-traumatic instability were pleased with the result of their operations


Bone & Joint Research
Vol. 3, Issue 2 | Pages 38 - 47
1 Feb 2014
Hogendoorn S Duijnisveld BJ van Duinen SG Stoel BC van Dijk JG Fibbe WE Nelissen RGHH

Objectives. Traumatic brachial plexus injury causes severe functional impairment of the arm. Elbow flexion is often affected. Nerve surgery or tendon transfers provide the only means to obtain improved elbow flexion. Unfortunately, the functionality of the arm often remains insufficient. Stem cell therapy could potentially improve muscle strength and avoid muscle-tendon transfer. This pilot study assesses the safety and regenerative potential of autologous bone marrow-derived mononuclear cell injection in partially denervated biceps. Methods. Nine brachial plexus patients with insufficient elbow flexion (i.e., partial denervation) received intramuscular escalating doses of autologous bone marrow-derived mononuclear cells, combined with tendon transfers. Effect parameters included biceps biopsies, motor unit analysis on needle electromyography and computerised muscle tomography, before and after cell therapy. Results. No adverse effects in vital signs, bone marrow aspiration sites, injection sites, or surgical wound were seen. After cell therapy there was a 52% decrease in muscle fibrosis (p = 0.01), an 80% increase in myofibre diameter (p = 0.007), a 50% increase in satellite cells (p = 0.045) and an 83% increase in capillary-to-myofibre ratio (p < 0.001) was shown. CT analysis demonstrated a 48% decrease in mean muscle density (p = 0.009). Motor unit analysis showed a mean increase of 36% in motor unit amplitude (p = 0.045), 22% increase in duration (p = 0.005) and 29% increase in number of phases (p = 0.002). Conclusions. Mononuclear cell injection in partly denervated muscle of brachial plexus patients is safe. The results suggest enhanced muscle reinnervation and regeneration. Cite this article: Bone Joint Res 2014;3:38–47


The Journal of Bone & Joint Surgery British Volume
Vol. 82-B, Issue 1 | Pages 87 - 89
1 Jan 2000
Wigderowitz CA Rowley DI Mole PA Paterson CR Abel EW

To ascertain whether patients with Colles’ fracture should be investigated for osteoporosis and the risk of future fractures, we measured the bone mineral density of the distal radius of the other arm in 31 women patients and compared the results with those of a control group of 289 normal women. We divided the patients into two groups, those younger than 66 years and those older. In 25 patients we found values for bone mineral density which were lower than one standard deviation below the mean value for their age. Younger patients had a deficit greater than that expected for their ages. We believe that women with Colles’ fracture should be evaluated routinely for osteoporosis, particularly if they are under 66 years of age


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 5 | Pages 623 - 628
1 May 2006
Gong HS Chung MS Lee YH Lee S Lee JO Baek GH

We have performed a form of lunate replacement arthroplasty, which included excision of the lunate and insertion of a vascularised radial bone flap wrapped in pronator quadratus, for stage IIIB or stage IV Kienböck’s disease, in 41 patients who have been followed up for more than three years. All patients reported an improvement in their symptoms, and 20 of the 41 became free of pain after the operation. Extension and flexion of the wrist were increased by a mean of 9° and 6°, respectively (p < 0.05). The radioscaphoid angle and the carpal height ratio were not significantly changed and only minimal deterioration was observed due to degenerative change. The size, density or location of the inserted bone did not change with time. A vascularised radial bone flap wrapped in pronator quadratus can be a reliable treatment option for advanced Kienböck’s disease, when the pedicled bone and muscle envelope acts as a stable spacer for the excised lunate


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 5 | Pages 671 - 677
1 May 2012
Raiss P Sowa B Bruckner T Eck S Woerz S Rohr K Rickert M Kasten P

The aim of this study was to compare a third-generation cementing procedure for glenoid components with a new technique for cement pressurisation. In 20 pairs of scapulae, 20 keeled and 20 pegged glenoid components were implanted using either a third-generation cementing technique (group 1) or a new pressuriser (group 2). Cement penetration was measured by three-dimensional (3D) analysis of micro-CT scans. The mean 3D depth of penetration of the cement was significantly greater in group 2 (p < 0.001). The mean thickness of the cement mantle for keeled glenoids was 2.50 mm (2.0 to 3.3) in group 1 and 5.18 mm (4.4 to 6.1) in group 2, and for pegged glenoids it was 1.72 mm (0.9 to 2.3) in group 1 and 5.63 mm (3.6 to 6.4) in group 2. A cement mantle < 2 mm was detected less frequently in group 2 (p < 0.001). Using the cement pressuriser the proportion of cement mantles < 2 mm was significantly reduced compared with the third-generation cementing technique.


Bone & Joint Research
Vol. 13, Issue 10 | Pages 596 - 610
21 Oct 2024
Toegel S Martelanz L Alphonsus J Hirtler L Gruebl-Barabas R Cezanne M Rothbauer M Heuberer P Windhager R Pauzenberger L

Aims. This study aimed to define the histopathology of degenerated humeral head cartilage and synovial inflammation of the glenohumeral joint in patients with omarthrosis (OmA) and cuff tear arthropathy (CTA). Additionally, the potential of immunohistochemical tissue biomarkers in reflecting the degeneration status of humeral head cartilage was evaluated. Methods. Specimens of the humeral head and synovial tissue from 12 patients with OmA, seven patients with CTA, and four body donors were processed histologically for examination using different histopathological scores. Osteochondral sections were immunohistochemically stained for collagen type I, collagen type II, collagen neoepitope C1,2C, collagen type X, and osteocalcin, prior to semiquantitative analysis. Matrix metalloproteinase (MMP)-1, MMP-3, and MMP-13 levels were analyzed in synovial fluid using enzyme-linked immunosorbent assay (ELISA). Results. Cartilage degeneration of the humeral head was associated with the histological presentation of: 1) pannus overgrowing the cartilage surface; 2) pores in the subchondral bone plate; and 3) chondrocyte clusters in OmA patients. In contrast, hyperplasia of the synovial lining layer was revealed as a significant indicator of inflammatory processes predominantly in CTA. The abundancy of collagen I, collagen II, and the C1,2C neoepitope correlated significantly with the histopathological degeneration of humeral head cartilage. No evidence for differences in MMP levels between OmA and CTA patients was found. Conclusion. This study provides a comprehensive histological characterization of humeral cartilage and synovial tissue within the glenohumeral joint, both in normal and diseased states. It highlights synovitis and pannus formation as histopathological hallmarks of OmA and CTA, indicating their roles as drivers of joint inflammation and cartilage degradation, and as targets for therapeutic strategies such as rotator cuff reconstruction and synovectomy. Cite this article: Bone Joint Res 2024;13(10):596–610


Bone & Joint Research
Vol. 13, Issue 4 | Pages 169 - 183
15 Apr 2024
Gil-Melgosa L Llombart-Blanco R Extramiana L Lacave I Abizanda G Miranda E Agirre X Prósper F Pineda-Lucena A Pons-Villanueva J Pérez-Ruiz A

Aims. Rotator cuff (RC) injuries are characterized by tendon rupture, muscle atrophy, retraction, and fatty infiltration, which increase injury severity and jeopardize adequate tendon repair. Epigenetic drugs, such as histone deacetylase inhibitors (HDACis), possess the capacity to redefine the molecular signature of cells, and they may have the potential to inhibit the transformation of the fibro-adipogenic progenitors (FAPs) within the skeletal muscle into adipocyte-like cells, concurrently enhancing the myogenic potential of the satellite cells. Methods. HDACis were added to FAPs and satellite cell cultures isolated from mice. The HDACi vorinostat was additionally administered into a RC injury animal model. Histological analysis was carried out on the isolated supra- and infraspinatus muscles to assess vorinostat anti-muscle degeneration potential. Results. Vorinostat, a HDACi compound, blocked the adipogenic transformation of muscle-associated FAPs in culture, promoting myogenic progression of the satellite cells. Furthermore, it protected muscle from degeneration after acute RC in mice in the earlier muscle degenerative stage after tenotomy. Conclusion. The HDACi vorinostat may be a candidate to prevent early muscular degeneration after RC injury. Cite this article: Bone Joint Res 2024;13(4):169–183


Bone & Joint Research
Vol. 13, Issue 10 | Pages 588 - 595
17 Oct 2024
Breu R Avelar C Bertalan Z Grillari J Redl H Ljuhar R Quadlbauer S Hausner T

Aims. The aim of this study was to create artificial intelligence (AI) software with the purpose of providing a second opinion to physicians to support distal radius fracture (DRF) detection, and to compare the accuracy of fracture detection of physicians with and without software support. Methods. The dataset consisted of 26,121 anonymized anterior-posterior (AP) and lateral standard view radiographs of the wrist, with and without DRF. The convolutional neural network (CNN) model was trained to detect the presence of a DRF by comparing the radiographs containing a fracture to the inconspicuous ones. A total of 11 physicians (six surgeons in training and five hand surgeons) assessed 200 pairs of randomly selected digital radiographs of the wrist (AP and lateral) for the presence of a DRF. The same images were first evaluated without, and then with, the support of the CNN model, and the diagnostic accuracy of the two methods was compared. Results. At the time of the study, the CNN model showed an area under the receiver operating curve of 0.97. AI assistance improved the physician’s sensitivity (correct fracture detection) from 80% to 87%, and the specificity (correct fracture exclusion) from 91% to 95%. The overall error rate (combined false positive and false negative) was reduced from 14% without AI to 9% with AI. Conclusion. The use of a CNN model as a second opinion can improve the diagnostic accuracy of DRF detection in the study setting. Cite this article: Bone Joint Res 2024;13(10):588–595


Bone & Joint Research
Vol. 13, Issue 9 | Pages 474 - 484
10 Sep 2024
Liu Y Li X Jiang L Ma J

Aims. Rotator cuff tear (RCT) is the leading cause of shoulder pain, primarily associated with age-related tendon degeneration. This study aimed to elucidate the potential differential gene expressions in tendons across different age groups, and to investigate their roles in tendon degeneration. Methods. Linear regression and differential expression (DE) analyses were performed on two transcriptome profiling datasets of torn supraspinatus tendons to identify age-related genes. Subsequent functional analyses were conducted on these candidate genes to explore their potential roles in tendon ageing. Additionally, a secondary DE analysis was performed on candidate genes by comparing their expressions between lesioned and normal tendons to explore their correlations with RCTs. Results. We identified 49 genes in torn supraspinatus tendons associated with advancing age. Among them, five age-related genes showed DE in lesioned tendons compared to normal tendons. Functional analyses and previous studies have highlighted their specific enrichments in biological functions, such as muscle development (e.g. myosin heavy chain 3 (MYH3)), transcription regulation (e.g. CCAAT enhancer binding brotein delta (CEBPD)), and metal ion homeostasis (e.g. metallothionein 1X (MT1X)). Conclusion. This study uncovered molecular aspects of tendon ageing and their potential links to RCT development, offering insights for targeted interventions. These findings enhance our understanding of the mechanisms of tendon degeneration, allowing potential strategies to be made for reducing the incidence of RCT. Cite this article: Bone Joint Res 2024;13(9):474–484


Bone & Joint Research
Vol. 12, Issue 8 | Pages 455 - 466
1 Aug 2023
Zhou H Chen C Hu H Jiang B Yin Y Zhang K Shen M Wu S Wang Z

Aims. Rotator cuff muscle atrophy and fatty infiltration affect the clinical outcomes of rotator cuff tear patients. However, there is no effective treatment for fatty infiltration at this time. High-intensity interval training (HIIT) helps to activate beige adipose tissue. The goal of this study was to test the role of HIIT in improving muscle quality in a rotator cuff tear model via the β3 adrenergic receptor (β3AR). Methods. Three-month-old C57BL/6 J mice underwent a unilateral rotator cuff injury procedure. Mice were forced to run on a treadmill with the HIIT programme during the first to sixth weeks or seventh to 12th weeks after tendon tear surgery. To study the role of β3AR, SR59230A, a selective β3AR antagonist, was administered to mice ten minutes before each exercise through intraperitoneal injection. Supraspinatus muscle, interscapular brown fat, and inguinal subcutaneous white fat were harvested at the end of the 12th week after tendon tear and analyzed biomechanically, histologically, and biochemically. Results. Histological analysis of supraspinatus muscle showed that HIIT improved muscle atrophy, fatty infiltration, and contractile force compared to the no exercise group. In the HIIT groups, supraspinatus muscle, interscapular brown fat, and inguinal subcutaneous white fat showed increased expression of tyrosine hydroxylase and uncoupling protein 1, and upregulated the β3AR thermogenesis pathway. However, the effect of HIIT was not present in mice injected with SR59230A, suggesting that HIIT affected muscles via β3AR. Conclusion. HIIT improved supraspinatus muscle quality and function after rotator cuff tears by activating systemic sympathetic nerve fibre near adipocytes and β3AR. Cite this article: Bone Joint Res 2023;12(8):455–466


Bone & Joint Research
Vol. 12, Issue 3 | Pages 165 - 177
1 Mar 2023
Boyer P Burns D Whyne C

Aims. An objective technological solution for tracking adherence to at-home shoulder physiotherapy is important for improving patient engagement and rehabilitation outcomes, but remains a significant challenge. The aim of this research was to evaluate performance of machine-learning (ML) methodologies for detecting and classifying inertial data collected during in-clinic and at-home shoulder physiotherapy exercise. Methods. A smartwatch was used to collect inertial data from 42 patients performing shoulder physiotherapy exercises for rotator cuff injuries in both in-clinic and at-home settings. A two-stage ML approach was used to detect out-of-distribution (OOD) data (to remove non-exercise data) and subsequently for classification of exercises. We evaluated the performance impact of grouping exercises by motion type, inclusion of non-exercise data for algorithm training, and a patient-specific approach to exercise classification. Algorithm performance was evaluated using both in-clinic and at-home data. Results. The patient-specific approach with engineered features achieved the highest in-clinic performance for differentiating physiotherapy exercise from non-exercise activity (area under the receiver operating characteristic (AUROC) = 0.924). Including non-exercise data in algorithm training further improved classifier performance (random forest, AUROC = 0.985). The highest accuracy achieved for classifying individual in-clinic exercises was 0.903, using a patient-specific method with deep neural network model extracted features. Grouping exercises by motion type improved exercise classification. For at-home data, OOD detection yielded similar performance with the non-exercise data in the algorithm training (fully convolutional network AUROC = 0.919). Conclusion. Including non-exercise data in algorithm training improves detection of exercises. A patient-specific approach leveraging data from earlier patient-supervised sessions should be considered but is highly dependent on per-patient data quality. Cite this article: Bone Joint Res 2023;12(3):165–177


Bone & Joint Research
Vol. 12, Issue 2 | Pages 103 - 112
1 Feb 2023
Walter N Szymski D Kurtz SM Lowenberg DW Alt V Lau E Rupp M

Aims. The optimal choice of management for proximal humerus fractures (PHFs) has been increasingly discussed in the literature, and this work aimed to answer the following questions: 1) what are the incidence rates of PHF in the geriatric population in the USA; 2) what is the mortality rate after PHF in the elderly population, specifically for distinct treatment procedures; and 3) what factors influence the mortality rate?. Methods. PHFs occurring between 1 January 2009 and 31 December 2019 were identified from the Medicare physician service records. Incidence rates were determined, mortality rates were calculated, and semiparametric Cox regression was applied, incorporating 23 demographic, clinical, and socioeconomic covariates, to compare the mortality risk between treatments. Results. From 2009 to 2019, the incidence decreased by 11.85% from 300.4 cases/100,000 enrollees to 266.3 cases/100,000 enrollees, although this was not statistically significant (z = -1.47, p = 0.142). In comparison to matched Medicare patients without a PHF, but of the same five-year age group and sex, a mean survival difference of -17.3% was observed. The one-year mortality rate was higher after nonoperative treatment with 16.4% compared to surgical treatment with 9.3% (hazard ratio (HR) = 1.29, 95% confidence interval (CI) 1.23 to 1.36; p < 0.001) and to shoulder arthroplasty with 7.4% (HR = 1.45, 95% CI 1.33 to 1.58; p < 0.001). Statistically significant mortality risk factors after operative treatment included age older than 75 years, male sex, chronic obstructive pulmonary disease (COPD), cerebrovascular disease, chronic kidney disease, a concomitant fracture, congestive heart failure, and osteoporotic fracture. Conclusion. Mortality risk factors for distinct treatment modes after PHF in elderly patients could be identified, which may guide clinical decision-making. Cite this article: Bone Joint Res 2023;12(2):103–112


Bone & Joint Research
Vol. 10, Issue 5 | Pages 298 - 306
1 May 2021
Dolkart O Kazum E Rosenthal Y Sher O Morag G Yakobson E Chechik O Maman E

Aims. Rotator cuff (RC) tears are common musculoskeletal injuries which often require surgical intervention. Noninvasive pulsed electromagnetic field (PEMF) devices have been approved for treatment of long-bone fracture nonunions and as an adjunct to lumbar and cervical spine fusion surgery. This study aimed to assess the effect of continuous PEMF on postoperative RC healing in a rat RC repair model. Methods. A total of 30 Wistar rats underwent acute bilateral supraspinatus tear and repair. A miniaturized electromagnetic device (MED) was implanted at the right shoulder and generated focused PEMF therapy. The animals’ left shoulders served as controls. Biomechanical, histological, and bone properties were assessed at three and six weeks. Results. Extension of the tendon from preload to the maximum load to failure was significantly better in the PEMF-treated shoulders at three weeks compared to controls (p = 0.038). The percentage strain was significantly higher in the PEMF group at both timepoints (p = 0.037). Collagen organization was significantly better (p = 0.034) as was tissue mineral density in the PEMF-treated group at three weeks (p = 0.028). Tendon immunohistochemistry revealed a prominent increase in type I collagen at the repair site at three weeks following continuous PEMF treatment compared with controls. None of the other tested parameters differed between the groups. Conclusion. MED-generated PEMF may enhance early postoperative tendon-to-bone healing in an acute rat supraspinatus detachment and repair model. Superior biomechanical elasticity parameters together with better collagen organization suggest improved RC healing. Cite this article: Bone Joint Res 2021;10(5):298–306


Bone & Joint Research
Vol. 10, Issue 2 | Pages 113 - 121
1 Feb 2021
Nicholson JA Oliver WM MacGillivray TJ Robinson CM Simpson AHRW

Aims. To evaluate if union of clavicle fractures can be predicted at six weeks post-injury by the presence of bridging callus on ultrasound. Methods. Adult patients managed nonoperatively with a displaced mid-shaft clavicle were recruited prospectively. Ultrasound evaluation of the fracture was undertaken to determine if sonographic bridging callus was present. Clinical risk factors at six weeks were used to stratify patients at high risk of nonunion with a combination of Quick Disabilities of the Arm, Shoulder and Hand questionnaire (QuickDASH) ≥ 40, fracture movement on examination, or absence of callus on radiograph. Results. A total of 112 patients completed follow-up at six months with a nonunion incidence of 16.7% (n = 18/112). Sonographic bridging callus was detected in 62.5% (n = 70/112) of the cohort at six weeks post-injury. If present, union occurred in 98.6% of the fractures (n = 69/70). If absent, nonunion developed in 40.5% of cases (n = 17/42). The sensitivity to predict union with sonographic bridging callus at six weeks was 73.4% and the specificity was 94.4%. Regression analysis found that failure to detect sonographic bridging callus at six weeks was associated with older age, female sex, simple fracture pattern, smoking, and greater fracture displacement (Nagelkerke R. 2. = 0.48). Of the cohort, 30.4% (n = 34/112) had absent sonographic bridging callus in addition to one or more of the clinical risk factors at six weeks that predispose to nonunion. If one was present the nonunion rate was 35%, 60% with two, and 100% when combined with all three. Conclusion. Ultrasound combined with clinical risk factors can accurately predict fracture healing at six weeks following a displaced midshaft clavicle fracture. Cite this article: Bone Joint Res 2021;10(2):113–121


Bone & Joint Research
Vol. 8, Issue 3 | Pages 118 - 125
1 Mar 2019
Doi N Izaki T Miyake S Shibata T Ishimatsu T Shibata Y Yamamoto T

Objectives. Indocyanine green (ICG) fluorescence angiography is an emerging technique that can provide detailed anatomical information during surgery. The purpose of this study is to determine whether ICG fluorescence angiography can be used to evaluate the blood flow of the rotator cuff tendon in the clinical setting. Methods. Twenty-six patients were evaluated from October 2016 to December 2017. The participants were categorized into three groups based on their diagnoses: the rotator cuff tear group; normal rotator cuff group; and adhesive capsulitis group. After establishing a posterior standard viewing portal, intravenous administration of ICG at 0.2 mg/kg body weight was performed, and fluorescence images were recorded. The time from injection of the drug to the beginning of enhancement of the observed area was measured. The hypovascular area in the rotator cuff was evaluated, and the ratio of the hypovascular area to the anterolateral area of the rotator cuff tendon was calculated (hypovascular area ratio). Results. ICG fluorescence angiography allowed for visualization of blood flow in the rotator cuff in all groups. The adhesive capsulitis group showed significantly earlier enhancement than the other groups. Furthermore, the adhesive capsulitis group had a significantly smaller hypovascular area ratio than the other groups. Conclusion. ICG fluorescence angiography allowed for evaluation of real-time blood flow of the rotator cuff in arthroscopic shoulder surgery. The techniques of ICG fluorescence angiography are simple and easy to observe, observer reliability is high, and it has utility for evaluating blood flow during surgery. Cite this article: N. Doi, T. Izaki, S. Miyake, T. Shibata, T. Ishimatsu, Y. Shibata, T. Yamamoto. Intraoperative evaluation of blood flow for soft tissues in orthopaedic surgery using indocyanine green fluorescence angiography: A pilot study. Bone Joint Res 2019;8:118–125. DOI: 10.1302/2046-3758.83.BJR-2018-0151.R1


Bone & Joint Research
Vol. 7, Issue 6 | Pages 422 - 429
1 Jun 2018
Acklin YP Zderic I Inzana JA Grechenig S Schwyn R Richards RG Gueorguiev B

Aims. Plating displaced proximal humeral fractures is associated with a high rate of screw perforation. Dynamization of the proximal screws might prevent these complications. The aim of this study was to develop and evaluate a new gliding screw concept for plating proximal humeral fractures biomechanically. Methods. Eight pairs of three-part humeral fractures were randomly assigned for pairwise instrumentation using either a prototype gliding plate or a standard PHILOS plate, and four pairs were fixed using the gliding plate with bone cement augmentation of its proximal screws. The specimens were cyclically tested under progressively increasing loading until perforation of a screw. Telescoping of a screw, varus tilting and screw migration were recorded using optical motion tracking. Results. Mean initial stiffness (N/mm) was 581.3 (. sd. 239.7) for the gliding plate, 631.5 (. sd. 160.0) for the PHILOS and 440.2 (. sd. 97.6) for the gliding augmented plate without significant differences between the groups (p = 0.11). Mean varus tilting (°) after 7500 cycles was comparable between the gliding plate (2.6; . sd. 1.9), PHILOS (1.2; . sd. 0.6) and gliding augmented plate (1.7; . sd. 0.9) (p = 0.10). Similarly, mean screw migration(mm) after 7500 cycles was similar between the gliding plate (3.02; . sd. 2.85), PHILOS (1.30; . sd. 0.44) and gliding augmented plate (2.83; . sd. 1.18) (p = 0.13). Mean number of cycles until failure with 5° varus tilting were 12702 (. sd. 3687) for the gliding plate, 13948 (. sd. 1295) for PHILOS and 13189 (. sd. 2647) for the gliding augmented plate without significant differences between the groups (p = 0.66). Conclusion. Biomechanically, plate fixation using a new gliding screw technology did not show considerable advantages in comparison with fixation using a standard PHILOS plate. Based on the finding of telescoping of screws, however, it may represent a valid approach for further investigations into how to avoid the cut-out of screws. Cite this article: Y. P. Acklin, I. Zderic, J. A. Inzana, S. Grechenig, R. Schwyn, R. G. Richards, B. Gueorguiev. Biomechanical evaluation of a new gliding screw concept for the fixation of proximal humeral fractures. Bone Joint Res 2018;7:422–429. DOI: 10.1302/2046-3758.76.BJR-2017-0356.R1


The Bone & Joint Journal
Vol. 98-B, Issue 1 | Pages 81 - 87
1 Jan 2016
Miska M Findeisen S Tanner M Biglari B Studier-Fischer S Grützner PA Schmidmaier G Moghaddam A

Methods. Between 2005 and 2012, 50 patients (23 female, 27 male) with nonunion of the humeral shaft were included in this retrospective study. The mean age was 51.3 years (14 to 88). The patients had a mean of 1.5 prior operations (. sd. 1.2;1 to 8). All patients were assessed according to a specific risk score in order to devise an optimal and individual therapy plan consistent with the Diamond Concept. In 32 cases (64%), a change in the osteosynthesis to an angular stable locking compression plate was performed. According to the individual risk an additional bone graft and/or bone morphogenetic protein-7 (BMP-7) were applied. Results. A successful consolidation of the nonunion was observed in 37 cases (80.4%) with a median healing time of six months (IQR 6). Younger patients showed significantly better consolidation. Four patients were lost to follow-up. Revision was necessary in a total of eight (16%) cases. In the initial treatment, intramedullary nailing was most common. . Discussion. The use of locking compression plates in combination with autologous cancellous bone graft has been shown to be a safe and effective treatment. In more complex cases, the use of the Masquelet technique and BMP-7 may be indicated at the first revision operation. Take home message: Our results suggest the Diamond Concept is a successful treatment strategy for nonunions of the humeral shaft. Cite this article: Bone Joint J 2016;98-B:81–7


Bone & Joint Research
Vol. 5, Issue 5 | Pages 175 - 177
1 May 2016
Rubin G Rinott M Wolovelsky A Rosenberg L Shoham Y Rozen N

Objectives. Injectable Bromelain Solution (IBS) is a modified investigational derivate of the medical grade bromelain-debriding pharmaceutical agent (NexoBrid) studied and approved for a rapid (four-hour single application), eschar-specific, deep burn debridement. We conducted an ex vivo study to determine the ability of IBS to dissolve-disrupt (enzymatic fasciotomy) Dupuytren’s cords. Materials and Methods. Specially prepared medical grade IBS was injected into fresh Dupuytren’s cords excised from patients undergoing surgical fasciectomy. These cords were tested by tension-loading them to failure with the Zwick 1445 (Zwick GmbH & Co. KG, Ulm, Germany) tension testing system. Results. We completed a pilot concept-validation study that proved the efficacy of IBS to induce enzymatic fasciotomy in ten cords compared with control in ten cords. We then completed a dosing study with an additional 71 cords injected with IBS in descending doses from 150 mg/cc to 0.8 mg/cc. The dosing study demonstrated that the minimal effective dose of 0.5 cc of 6.25 mg/cc to 5 mg/cc could achieve cord rupture in more than 80% of cases. Conclusions. These preliminary results indicate that IBS may be effective in enzymatic fasciotomy in Dupuytren’s contracture. Cite this article: Dr G. Rubin. A new bromelain-based enzyme for the release of Dupuytren’s contracture: Dupuytren’s enzymatic bromelain-based release. Bone Joint Res 2016;5:175–177. DOI: 10.1302/2046-3758.55.BJR-2016-0072


The Bone & Joint Journal
Vol. 98-B, Issue 4 | Pages 519 - 525
1 Apr 2016
Lees DA Penny JB Baker P

Aims. The aim of this study was to compare the pain caused by the application of a tourniquet after exsanguination of the upper limb with that occurring after simple elevation. . Patients and Methods. We used 26 healthy volunteers (52 arms), each of whom acted as their own matched control. The primary outcome measure was the total pain experienced by each volunteer while the tourniquet was inflated for 20 minutes. This was calculated as the area under the pain curve for each individual subject. Secondary outcomes were pain at each time point; the total pain experienced during the recovery phase; the ability to tolerate the tourniquet and the time for full recovery after deflation of the tourniquet. . Results. There was a significant difference in the area under the pain curves in favour of exsanguination (mean difference 8.4; 95% confidence interval (CI) 3.0 to 13.7, p = 0.004). There was no difference between the dominant and non-dominant arms (mean difference -0.2; 95% CI -23.2 to 22.8, p = 0.99). The area under both recovery curves were similar (mean difference 0.7; 95% CI -6.0 to 4.6, p = 0.78). There was no statistical difference in recovery time, the actual mean difference being 30 seconds longer in the elevation group (p = 0.06). Conclusion. Many orthopaedic and plastic surgery procedures are done under local anaesthetic or regional block where a bloodless field and a motionless patient are essential. Optimising patient comfort during surgery with the tourniquet inflated is thus a priority. This study is useful in that it compares two common methods of preparation of the upper limb prior to tourniquet inflation and which have not previously been compared in this context. Following on the results of this study, we can confidently conclude that exsanguinating the upper limb before inflating a tourniquet is more comfortable than simply elevating the arm for patients undergoing a procedure under local or regional block, both during the procedure and in the recovery phase. . Take home message: Exsanguination rather than elevation is recommended in order to minimise patient discomfort and optimise the surgical field. Cite this article: Bone Joint J 2016;98-B:519–25


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 1 | Pages 80 - 85
1 Jan 2012
Malone AA Sanchez JS Adams R Morrey B

We report the effectiveness of revision of total elbow replacement by re-cementing. Between 1982 and 2004, 53 elbows in 52 patients were treated with re-cementing of a total elbow replacement into part or all of the existing cement mantle or into the debrided host-bone interface, without the use of structural bone augmentation or a custom prosthesis. The original implant revision was still in situ and functional in 42 of 53 elbows (79%) at a mean of 94.5 months (26 to 266) after surgery. In 31 of these 42 elbows (74%) the Mayo Elbow Performance Score was good or excellent. Overall, of the 53 elbows, 18 (34%) required re-operation, ten (19%) for loosening. A classification system was developed to identify those not suitable for revision by this technique, and using this we have showed that successful re-implantation is statistically correlated to properly addressing the bone deficiency for both the humeral (p = 0.005) and the ulnar (p = 0.039) components


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 4 | Pages 490 - 494
1 Apr 2007
Arimitsu S Murase T Hashimoto J Oka K Sugamoto K Yoshikawa H Moritomo H

We have measured the three-dimensional patterns of carpal deformity in 20 wrists in 20 rheumatoid patients in which the carpal bones were shifted ulnarwards on plain radiography. Three-dimensional bone models of the carpus and radius were created by computerised tomography with the wrist in the neutral position. The location of the centroids and rotational angle of each carpal bone relative to the radius were calculated and compared with those of ten normal wrists. In the radiocarpal joint, the proximal row was flexed and the centroids of all carpal bones translocated in an ulnar, proximal and volar direction with loss of congruity. In the midcarpal joint, the distal row was extended and congruity generally well preserved. These findings may facilitate more positive use of radiocarpal fusion alone for the deformed rheumatoid wrist


The Bone & Joint Journal
Vol. 95-B, Issue 3 | Pages 396 - 400
1 Mar 2013
Rhee SH Kim J Lee YH Gong HS Lee HJ Baek GH

The purpose of this study was to evaluate the risk of late displacement after the treatment of distal radial fractures with a locking volar plate, and to investigate the clinical and radiological factors that might correlate with re-displacement. From March 2007 to October 2009, 120 of an original cohort of 132 female patients with unstable fractures of the distal radius were treated with a volar locking plate, and were studied over a follow-up period of six months. In the immediate post-operative and final follow-up radiographs, late displacement was evaluated as judged by ulnar variance, radial inclination, and dorsal angulation. We also analysed the correlation of a variety of clinical and radiological factors with re-displacement. Ulnar variance was significantly overcorrected (p < 0.001) while radial inclination and dorsal angulation were undercorrected when compared statistically (p <  0.001) with the unaffected side in the immediate post-operative stage. During follow-up, radial shortening and dorsal angulation progressed statistically, but none had a value beyond the acceptable range. Bone mineral density measured at the proximal femur and the position of the screws in the subchondral region, correlated with slight progressive radial shortening, which was not clinically relevant. Volar locking plating of distal radial fractures is a reliable form of treatment without substantial late displacement. Cite this article: Bone Joint J 2013;95-B:396–400


The Bone & Joint Journal
Vol. 95-B, Issue 6 | Pages 809 - 814
1 Jun 2013
Park HY Yoon JO Jeon IH Chung HW Kim JS

This study was performed to determine whether pure cancellous bone graft and Kirschner (K-) wire fixation were sufficient to achieve bony union and restore alignment in scaphoid nonunion. A total of 65 patients who underwent cancellous bone graft and K-wire fixation were included in this study. The series included 61 men and four women with a mean age of 34 years (15 to 72) and mean delay to surgery of 28.7 months (3 to 240). The patients were divided into an unstable group (A) and stable group (B) depending on the pre-operative radiographs. Unstable nonunion was defined as a lateral intrascaphoid angle > 45°, or a radiolunate angle > 10°. There were 34 cases in group A and 31 cases in group B. Bony union was achieved in 30 patients (88.2%) in group A, and in 26 (83.9%) in group B (p = 0.439). Comparison of the post-operative radiographs between the two groups showed no significant differences in lateral intrascaphoid angle (p = 0.657) and scaphoid length (p = 0.670) and height (p = 0.193). The radiolunate angle was significantly different (p = 0.020) but the mean value in both groups was < 10°. Comparison of the dorsiflexion and palmar flexion of movement of the wrist and the mean Mayo wrist score at the final clinical visit in each group showed no significant difference (p = 0.190, p = 0.587 and p = 0.265, respectively). Cancellous bone graft and K-wire fixation were effective in the treatment of stable and unstable scaphoid nonunion. Cite this article: Bone Joint J 2013;95-B:809–14


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 8 | Pages 1077 - 1085
1 Aug 2012
Yin Z Zhang J Kan S Wang X

Follow-up radiographs are usually used as the reference standard for the diagnosis of suspected scaphoid fractures. However, these are prone to errors in interpretation. We performed a meta-analysis of 30 clinical studies on the diagnosis of suspected scaphoid fractures, in which agreement data between any of follow-up radiographs, bone scintigraphy, magnetic resonance (MR) imaging, or CT could be obtained, and combined this with latent class analysis to infer the accuracy of these tests on the diagnosis of suspected scaphoid fractures in the absence of an established standard. The estimated sensitivity and specificity were respectively 91.1% and 99.8% for follow-up radiographs, 97.8% and 93.5% for bone scintigraphy, 97.7% and 99.8% for MRI, and 85.2% and 99.5% for CT. The results were generally robust in multiple sensitivity analyses. There was large between-study heterogeneity for the sensitivity of follow-up radiographs and CT, and imprecision about their sensitivity estimates. If we acknowledge the lack of a reference standard for diagnosing suspected scaphoid fractures, MRI is the most accurate test; follow-up radiographs and CT may be less sensitive, and bone scintigraphy less specific


The Bone & Joint Journal
Vol. 96-B, Issue 11 | Pages 1530 - 1534
1 Nov 2014
Uehara K Yasunaga H Morizaki Y Horiguchi H Fushimi K Tanaka S

Necrotising soft-tissue infections (NSTIs) of the upper limb are uncommon, but potentially life-threatening. We used a national database to investigate the risk factors for amputation of the limb and death. . We extracted data from the Japanese Diagnosis Procedure Combination database on 116 patients (79 men and 37 women) who had a NSTI of the upper extremity between 2007 and 2010. The overall in-hospital mortality was 15.5%. Univariate analysis of in-hospital mortality showed that the significant variables were age (p = 0.015), liver dysfunction (p = 0.005), renal dysfunction (P < 0.001), altered consciousness (p = 0.049), and sepsis (p = 0.021). Logistic regression analysis showed that the factors associated with death in hospital were age over 70 years (Odds Ratio (OR) 6.6; 95% confidence interval (CI) 1.5 to 28.2; p = 0.011) and renal dysfunction (OR 15.4; 95% CI 3.8 to 62.8; p < 0.001). Univariate analysis of limb amputation showed that the significant variables were diabetes (p = 0.017) mellitus and sepsis (p = 0.001). Multivariable logistic regression analysis showed that the factors related to limb amputation were sepsis (OR 1.8; 95% CI 1.5 to 24.0; p = 0.013) and diabetes mellitus (OR 1.6; 95% CI 1.1 to 21.1; p = 0.038). . For NSTIs of the upper extremity, advanced age and renal dysfunction are both associated with a higher rate of in-hospital mortality. Sepsis and diabetes mellitus are both associated with a higher rate of amputation. Cite this article: Bone Joint J 2014;96-B:1530–4


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 9 | Pages 1260 - 1264
1 Sep 2012
Raiss P Lin A Mizuno N Melis B Walch G

A total of 12 epileptic patients (14 shoulders) with recurrent seizures and anterior dislocations of the shoulder underwent a Latarjet procedure and were reviewed at a mean of 8.3 years (1 to 20) post-operatively. Mean forward flexion decreased from 165° (100° to 180°) to 160° (90° to 180°) (p = 0.5) and mean external rotation from 54° (10° to 90°) to 43° (5° to 75°) (p = 0.058). The mean Rowe score was 76 (35 to 100) at the final follow-up. Radiologically, all shoulders showed a glenoid-rim defect and Hill-Sachs lesions pre-operatively. Osteo-arthritic changes of the glenohumeral joint were observed in five shoulders (36%) pre-operatively and in eight shoulders (57%) post-operatively. Re-dislocation during a seizure occurred in six shoulders (43%). Five of these patients underwent revision surgery using a bone buttress from the iliac crest and two of these patients re-dislocated due to a new seizure. . Due to the unacceptably high rate of re-dislocation after surgery in these patients, the most important means of reducing the incidence of further dislocation is the medical management of the seizures. The Latarjet procedure should be reserved for the well-controlled patient with epilepsy who has recurrent anterior dislocation of the shoulder during activities of daily living


The Bone & Joint Journal
Vol. 95-B, Issue 6 | Pages 721 - 731
1 Jun 2013
Sewell MD Al-Hadithy N Le Leu A Lambert SM

The sternoclavicular joint (SCJ) is a pivotal articulation in the linked system of the upper limb girdle, providing load-bearing in compression while resisting displacement in tension or distraction at the manubrium sterni. The SCJ and acromioclavicular joint (ACJ) both have a small surface area of contact protected by an intra-articular fibrocartilaginous disc and are supported by strong extrinsic and intrinsic capsular ligaments. The function of load-sharing in the upper limb by bulky periscapular and thoracobrachial muscles is extremely important to the longevity of both joints. Ligamentous and capsular laxity changes with age, exposing both joints to greater strain, which may explain the rising incidence of arthritis in both with age. The incidence of arthritis in the SCJ is less than that in the ACJ, suggesting that the extrinsic ligaments of the SCJ provide greater stability than the coracoclavicular ligaments of the ACJ. Instability of the SCJ is rare and can be difficult to distinguish from medial clavicular physeal or metaphyseal fracture-separation: cross-sectional imaging is often required. The distinction is important because the treatment options and outcomes of treatment are dissimilar, whereas the treatment and outcomes of ACJ separation and fracture of the lateral clavicle can be similar. Proper recognition and treatment of traumatic instability is vital as these injuries may be life-threatening. Instability of the SCJ does not always require surgical intervention. An accurate diagnosis is required before surgery can be considered, and we recommend the use of the Stanmore instability triangle. Most poor outcomes result from a failure to recognise the underlying pathology. There is a natural reluctance for orthopaedic surgeons to operate in this area owing to unfamiliarity with, and the close proximity of, the related vascular structures, but the interposed sternohyoid and sternothyroid muscles are rarely injured and provide a clear boundary to the medial retroclavicular space, as well as an anatomical barrier to unsafe intervention. This review presents current concepts of instability of the SCJ, describes the relevant surgical anatomy, provides a framework for diagnosis and management, including physiotherapy, and discusses the technical challenges of operative intervention. Cite this article: Bone Joint J 2013;95-B:721–31


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 7 | Pages 920 - 924
1 Jul 2006
Mori T Kudo H Iwano K Juji T

We studied 11 patients (14 elbows) with gross rheumatoid deformity of the elbow, treated by total arthroplasty using the Kudo type-5 unlinked prosthesis, and who were evaluated between five and 11 years after operation. Massive bone defects were augmented by autogenous bone grafts. There were no major complications such as infection, subluxation or loosening. In most elbows relief from pain and stability were achieved. The results, according to the Mayo Elbow Performance Score, were excellent in eight, good in five and fair in one. In most elbows there was minimal or no resorption of the grafted bone. There were no radiolucent lines around the stems of the cementless components. This study shows that even highly unstable rheumatoid elbows can be replaced successfully using an unlinked prosthesis, with augmentation by grafting for major defects of bone


The Bone & Joint Journal
Vol. 96-B, Issue 5 | Pages 574 - 579
1 May 2014
Talbot CL Ring J Holt EM

We present a review of claims made to the NHS Litigation Authority (NHSLA) by patients with conditions affecting the shoulder and elbow, and identify areas of dissatisfaction and potential improvement. Between 1995 and 2012, the NHSLA recorded 811 claims related to the shoulder and elbow, 581 of which were settled. This comprised 364 shoulder (64%), and 217 elbow (36%) claims. A total of £18.2 million was paid out in settled claims. Overall diagnosis, mismanagement and intra-operative nerve injury were the most common reasons for litigation. The highest cost paid out resulted from claims dealing with incorrect, missed or delayed diagnosis, with just under £6 million paid out overall. Fractures and dislocations around the shoulder and elbow were common injuries in this category. All 11 claims following wrong-site surgery that were settled led to successful payouts. This study highlights the diagnoses and procedures that need to be treated with particular vigilance. Having an awareness of the areas that lead to litigation in shoulder and elbow surgery will help to reduce inadvertent risks to patients and prevent dissatisfaction and possible litigation. . Cite this article: Bone Joint J 2014; 96-B:574–9


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 8 | Pages 1090 - 1096
1 Aug 2012
Mahmoud M El Shafie S Kamal M

Malunion is the most common complication of the distal radius with many modalities of treatment available for such a problem. The use of bone grafting after an osteotomy is still recommended by most authors. We hypothesised that bone grafting is not required; fixing the corrected construct with a volar locked plate helps maintain the alignment, while metaphyseal defect fills by itself. Prospectively, we performed the procedure on 30 malunited dorsally-angulated radii using fixed angle volar locked plates without bone grafting. At the final follow-up, 22 wrists were available. Radiological evidence of union, correction of the deformity, clinical and functional improvement was achieved in all cases. Without the use of bone grafting, corrective open wedge osteotomy fixed by a volar locked plate provides a high rate of union and satisfactory functional outcomes


The Bone & Joint Journal
Vol. 95-B, Issue 5 | Pages 660 - 663
1 May 2013
Ghosh S Singh VK Jeyaseelan L Sinisi M Fox M

In adults with brachial plexus injuries, lack of active external rotation at the shoulder is one of the most common residual deficits, significantly compromising upper limb function. There is a paucity of evidence to address this complex issue. We present our experience of isolated latissimus dorsi (LD) muscle transfer to achieve active external rotation. This is a retrospective review of 24 adult post-traumatic plexopathy patients who underwent isolated latissimus dorsi muscle transfer to restore external rotation of the shoulder between 1997 and 2010. All patients were male with a mean age of 34 years (21 to 57). All the patients underwent isolated LD muscle transfer using a standard technique to correct external rotational deficit. Outcome was assessed for improvement in active external rotation, arc of movement, muscle strength and return to work. The mean improvement in active external rotation from neutral was 24° (10° to 50°). The mean increase in arc of rotation was 52° (38° to 55°). Mean power of the external rotators was 3.5 Medical Research Council (MRC) grades (2 to 5). A total of 21 patients (88%) were back in work by the time of last follow up. Of these, 13 had returned to their pre-injury occupation. Isolated latissimus dorsi muscle transfer provides a simple and reliable method of restoring useful active external rotation in adults with brachial plexus injuries with internal rotational deformity. Cite this article: Bone Joint J 2013;95-B:660–3


The Bone & Joint Journal
Vol. 95-B, Issue 3 | Pages 391 - 395
1 Mar 2013
Klatte TO Junghans K Al-Khateeb H Rueger JM Gehrke T Kendoff D Neumann J

There have been only a few small studies of patients with an infected shoulder replacement treated with a single-stage exchange procedure. We retrospectively reviewed 35 patients (19 men and 16 women) with a peri-prosthetic infection of the shoulder who were treated in this way. A total of 26 were available for clinical examination; three had died, two were lost to follow-up and four patients had undergone revision surgery. The mean follow-up time was 4.7 years (1.1 to 13.25), with an infection-free survival of 94%. The organisms most commonly isolated intra-operatively were Staphylococcus epidermidis and Propionibacterium acnes; two patients developed a recurrent infection. Three different types of prosthesis were used: a hemiarthroplasty, a hemiarthroplasty with a bipolar head and reverse prosthesis. The mean Constant-Murley score at final follow-up was 43.3 (14 to 90) for patients with a hemiarthroplasty, 56 (40 to 88) for those with a hemiarthroplasty with a bipolar head and 61 (7 to 90) for those with a reverse prosthesis. The mean hospital stay was 10.6 days (5 to 29). Single-stage exchange is a successful and practical treatment for patients with peri-prosthetic infection of the shoulder. Cite this article: Bone Joint J 2013;95-B:391–5


The Bone & Joint Journal
Vol. 95-B, Issue 4 | Pages 530 - 535
1 Apr 2013
Roche CP Marczuk Y Wright TW Flurin P Grey S Jones R Routman HD Gilot G Zuckerman JD

This study provides recommendations on the position of the implant in reverse shoulder replacement in order to minimise scapular notching and osteophyte formation. Radiographs from 151 patients who underwent primary reverse shoulder replacement with a single prosthesis were analysed at a mean follow-up of 28.3 months (24 to 44) for notching, osteophytes, the position of the glenoid baseplate, the overhang of the glenosphere, and the prosthesis scapular neck angle (PSNA). A total of 20 patients (13.2%) had a notch (16 Grade 1 and four Grade 2) and 47 (31.1%) had an osteophyte. In patients without either notching or an osteophyte the baseplate was found to be positioned lower on the glenoid, with greater overhang of the glenosphere and a lower PSNA than those with notching and an osteophyte. Female patients had a higher rate of notching than males (13.3% vs 13.0%) but a lower rate of osteophyte formation (22.9% vs 50.0%), even though the baseplate was positioned significantly lower on the glenoid in females (p = 0.009) and each had a similar mean overhang of the glenosphere. Based on these findings we make recommendations on the placement of the implant in both male and female patients to avoid notching and osteophyte formation. Cite this article: Bone Joint J 2013;95-B:530–5


The Bone & Joint Journal
Vol. 95-B, Issue 4 | Pages 523 - 529
1 Apr 2013
Henseler JF Nagels J van der Zwaal P Nelissen RGHH

Surgical repair of posterosuperior rotator cuff tears has a poorer outcome and a higher rate of failure compared with repairs of supraspinatus tears. In this prospective cohort study 28 consecutive patients with an irreparable posterosuperior rotator cuff tear after failed conservative or surgical treatment underwent teres major tendon transfer. Their mean age was 60 years (48 to 71) and the mean follow-up was 25 months (12 to 80). The mean active abduction improved from 79° (0° to 150°) pre-operatively to 105° (20° to 180°) post-operatively (p = 0.011). The mean active external rotation in 90° abduction improved from 25° (0° to 70°) pre-operatively to 55° (0° to 90°) post-operatively (p < 0.001). The mean Constant score improved from 43 (18 to 78) pre-operatively to 65 (30 to 86) post-operatively (p < 0.001). The median post-operative VAS (0 to 100) for pain decreased from 63 (0 to 96) pre-operatively to 5 (0 to 56) post-operatively (p < 0.001). In conclusion, teres major transfer effectively restores function and relieves pain in patients with irreparable posterosuperior rotator cuff tears and leads to an overall clinical improvement in a relatively young and active patient group with limited treatment options. Cite this article: Bone Joint J 2013;95-B:523–9


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 7 | Pages 932 - 936
1 Jul 2011
Mahmoud M Koptan W

Ununited fractures of the scaphoid with extensive bone resorption are usually treated by bone grafting and internal fixation, using either an open or a minimally invasive technique. We studied the feasibility of percutaneous fixation without bone grafting in a consecutive series of 27 patients with established nonunion of an undisplaced fracture of the scaphoid and extensive local resorption of bone. They were treated by a single surgeon with rigid fixation alone, using a headless cannulated screw inserted through a volar percutaneous technique. Clinical examination, standard radiographs and CT confirmed that the fracture had united in all patients at a mean of 11.6 weeks (8 to 16), and that their functional scores had improved. We concluded that extensive resorption at the fracture site is not an absolute indication for bone grafting, and that percutaneous fixation alone will eventually produce healing of ununited undisplaced fractures of the scaphoid regardless of the size of the gap


The Bone & Joint Journal
Vol. 95-B, Issue 7 | Pages 942 - 946
1 Jul 2013
Dattani R Ramasamy V Parker R Patel VR

There is little published information on the health impact of frozen shoulder. The purpose of this study was to assess the functional and health-related quality of life outcomes following arthroscopic capsular release (ACR) for contracture of the shoulder. Between January 2010 and January 2012 all patients who had failed non-operative treatment including anti-inflammatory medication, physiotherapy and glenohumeral joint injections for contracture of the shoulder and who subsequently underwent an ACR were enrolled in the study. A total of 100 patients were eligible; 68 underwent ACR alone and 32 had ACR with a subacromial decompression (ASD). ACR resulted in a highly significant improvement in the range of movement and functional outcome, as measured by the Oxford shoulder score and EuroQol EQ-5D index. The mean cost of a quality-adjusted life year (QALY) for an ACR and ACR with an ASD was £2563 and £3189, respectively. . ACR is thus a cost-effective procedure that can restore relatively normal function and health-related quality of life in most patients with a contracture of the shoulder within six months after surgery; and the beneficial effects are not related to the duration of the presenting symptoms. Cite this article: Bone Joint J 2013;95-B:942–6


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 10 | Pages 1410 - 1415
1 Oct 2010
Castagna A Randelli M Garofalo R Maradei L Giardella A Borroni M

Total shoulder replacement is a successful procedure for degenerative or some inflammatory diseases of the shoulder. However, fixation of the glenoid seems to be the main weakness with a high rate of loosening. The results using all-polyethylene components have been better than those using metal-backed components. We describe our experience with 35 consecutive total shoulder replacements using a new metal-backed glenoid component with a mean follow-up of 75.4 months (48 to 154). Our implant differs from others because of its mechanism of fixation. It has a convex metal-backed bone interface and the main stabilising factor is a large hollow central peg. The patients were evaulated with standard radiographs and with the Constant Score, the Simple Shoulder Test and a visual analogue scale. All the scores improved and there was no loosening, no polyethylene-glenoid disassembly and no other implant-related complications. We conclude that a metal-backed glenoid component is a good option in total shoulder replacement with no worse results than of those using a cemented all-polyethylene prosthesis


The Bone & Joint Journal
Vol. 95-B, Issue 2 | Pages 146 - 150
1 Feb 2013
Sheibani-Rad S Wolfe S Jupiter J

Like athletes, musicians are vulnerable to musculoskeletal injuries that can be career ending or have a severe negative financial impact. All ages are affected, with a peak incidence in the third and fourth decades. Women are slightly more likely to be affected than men. It is incumbent upon orthopaedic surgeons to be able to complete a thorough physical assessment, be aware of the risk factors associated with musculoskeletal symptoms in musicians, and have a detailed knowledge of the specific syndromes they suffer and their appropriate treatment. In this paper we review the common hand injuries that afflict musicians and discuss their treatment. Cite this article: Bone Joint J 2013;95-B:146–50


The Bone & Joint Journal
Vol. 95-B, Issue 7 | Pages 935 - 941
1 Jul 2013
Moor BK Bouaicha S Rothenfluh DA Sukthankar A Gerber C

We hypothesised that a large acromial cover with an upwardly tilted glenoid fossa would be associated with degenerative rotator cuff tears (RCTs), and conversely, that a short acromion with an inferiorly inclined glenoid would be associated with glenohumeral osteoarthritis (OA). This hypothesis was tested using a new radiological parameter, the critical shoulder angle (CSA), which combines the measurements of inclination of the glenoid and the lateral extension of the acromion (the acromion index). The CSA was measured on standardised radiographs of three groups: 1) a control group of 94 asymptomatic shoulders with normal rotator cuffs and no OA; 2) a group of 102 shoulders with MRI-documented full-thickness RCTs without OA; and 3) a group of 102 shoulders with primary OA and no RCTs noted during total shoulder replacement. The mean CSA was 33.1° (26.8° to 38.6°) in the control group, 38.0° (29.5° to 43.5°) in the RCT group and 28.1° (18.6° to 35.8°) in the OA group. Of patients with a CSA > 35°, 84% were in the RCT group and of those with a CSA < 30°, 93% were in the OA group. We therefore concluded that primary glenohumeral OA is associated with significantly smaller degenerative RCTs with significantly larger CSAs than asymptomatic shoulders without these pathologies. These findings suggest that individual quantitative anatomy may imply biomechanics that are likely to induce specific types of degenerative joint disorders. Cite this article: Bone Joint J 2013;95-B:935–41


The Bone & Joint Journal
Vol. 95-B, Issue 7 | Pages 947 - 951
1 Jul 2013
Kang HJ Koh IH Jang JW Choi YR

The purpose of this study was to compare the outcome and complications of endoscopic versus open release for the treatment of de Quervain’s tenosynovitis. Patients with this condition were randomised to undergo either endoscopic (n = 27) or open release (n = 25). Visual Analogue Scale (VAS) pain and Disabilities of Arm, Shoulder, and Hand (DASH) scores were measured at 12 and 24 weeks after surgery. Scar satisfaction was measured using a VAS scale. The mean pain and DASH scores improved significantly at 12 weeks and 24 weeks (p <  0.001) in both groups. The scores were marginally lower in the endoscopic group compared to the open group at 12 weeks (p = 0.012 and p = 0.002, respectively); however, only the DASH score showed a clinically important difference. There were no differences between the groups at 24 weeks. The mean VAS scar satisfaction score was higher in the endoscopic group at 24 weeks (p < 0.001). Transient superficial radial nerve injury occurred in three patients in the endoscopic group compared with nine in the open release group (p = 0.033). We conclude that endoscopic release for de Quervain’s tenosynovitis seems to provide earlier improvement after surgery, with fewer superficial radial nerve complications and greater scar satisfaction, when compared with open release. Cite this article: Bone Joint J 2013;95-B:947–51


The Bone & Joint Journal
Vol. 95-B, Issue 7 | Pages 952 - 959
1 Jul 2013
Cai X Yan S Giddins G

Most patients with a nightstick fracture of the ulna are treated conservatively. Various techniques of immobilisation or early mobilisation have been studied. We performed a systematic review of all published randomised controlled trials and observational studies that have assessed the outcome of these fractures following above- or below-elbow immobilisation, bracing and early mobilisation. We searched multiple electronic databases, related bibliographies and other studies. We included 27 studies comprising 1629 fractures in the final analysis. The data relating to the time to radiological union and the rates of delayed union and nonunion could be pooled and analysed statistically. We found that early mobilisation produced the shortest radiological time to union (mean 8.0 weeks) and the lowest mean rate of nonunion (0.6%). Fractures treated with above- or below-elbow immobilisation and braces had longer mean radiological times to union (9.2 weeks, 9.2 weeks and 8.7 weeks, respectively) and higher mean rates of nonunion (3.8%, 2.1% and 0.8%, respectively). There was no statistically significant difference in the rate of non- or delayed union between those treated by early mobilisation and the three forms of immobilisation (p = 0.142 to p = 1.000, respectively). All the studies had significant biases, but until a robust randomised controlled trial is undertaken the best advice for the treatment of undisplaced or partially displaced nightstick fractures appears to be early mobilisation, with a removable forearm support for comfort as required. Cite this article: Bone Joint J 2013;95-B:952–9


The Bone & Joint Journal
Vol. 95-B, Issue 5 | Pages 657 - 659
1 May 2013
Bunker TD Cosker TDA Dunkerley S Kitson J Smith CD

Despite the expansion of arthroscopic surgery of the shoulder, the open deltopectoral approach to the shoulder is still frequently used, for example in fracture fixation and shoulder replacement. However, it is sometimes accompanied by unexpected bleeding. The cephalic vein is the landmark for the deltopectoral interval, yet its intimate relationship with the deltoid artery, and the anatomical variations in that structure, have not previously been documented. In this study the vascular anatomy encountered during 100 consecutive elective deltopectoral approaches was recorded and the common variants described. Two common variants of the deltoid artery were encountered. In type I (71%) it crosses the interval and tunnels into the deltoid muscle without encountering the cephalic vein. However, in type II (21%) it crosses the interval, reaches the cephalic vein and then runs down, medial to and behind it, giving off several small arterial branches that return back across the interval to the pectoralis major. Several minor variations were also seen (8%). These variations in the deltoid artery have not previously been described and may lead to confusion and unexpected bleeding during this standard anterior surgical approach to the shoulder. Cite this article: Bone Joint J 2013;95-B:657–9


The Bone & Joint Journal
Vol. 95-B, Issue 5 | Pages 664 - 667
1 May 2013
Rashid A Christofi T Thomas M

Lateral clavicular physeal injuries in adolescents are frequently misinterpreted as acromioclavicular dislocations. There are currently no clear guidelines for the management of these relatively rare injuries. Non-operative treatment can result in a cosmetic deformity, warranting resection of the non-remodelled original lateral clavicle. However, fixation with Kirschner (K)-wires may be associated with infection and/or prominent metalwork. We report our experience with a small series of such cases. Between October 2008 and October 2011 five patients with lateral clavicular physeal fractures (types III, IV and V) presented to our unit. There were four boys and one girl with a mean age of 12.8 years (9 to 14). Four fractures were significantly displaced and treated operatively using a tension band suture technique. One grade III fracture was treated conservatively. The mean follow-up was 26 months (6 to 42). All patients made an uncomplicated recovery. The mean time to discharge was three months. The QuickDASH score at follow-up was 0 for each patient. No patient developed subsequent growth disturbances. We advocate the surgical treatment of significantly displaced Grade IV and V fractures to avoid cosmetic deformity. A tension band suture technique avoids the problems of retained metalwork and the need for a secondary procedure. Excellent clinical and radiological results were seen in all our patients. Cite this article: Bone Joint J 2013;95-B:664–7


The Bone & Joint Journal
Vol. 95-B, Issue 4 | Pages 517 - 522
1 Apr 2013
Henry PDG Dwyer T McKee MD Schemitsch EH

Latissimus dorsi tendon transfer (LDTT) is technically challenging. In order to clarify the local structural anatomy, we undertook a morphometric study using six complete cadavers (12 shoulders). Measurements were made from the tendon to the nearby neurovascular structures with the arm in two positions: flexed and internally rotated, and adducted in neutral rotation. The tendon was then transferred and measurements were taken from the edge of the tendon to a reference point on the humeral head in order to assess the effect of a novel two-stage release on the excursion of the tendon. With the shoulder flexed and internally rotated, the mean distances between the superior tendon edge and the radial nerve, brachial artery, axillary nerve and posterior circumflex artery were 30 mm (26 to 34), 28 mm (17 to 39), 21 mm (12 to 28) and 15 mm (10 to 21), respectively. The mean distance between the inferior tendon edge and the radial nerve, brachial artery and profunda brachii artery was 18 mm (8 to 27), 22 mm (15 to 32) and 14 mm (7 to 21), respectively. Moving the arm to a neutral position reduced these distances. A mean of 15 mm (8 to 21) was gained from a standard soft-tissue release, and 32 mm (20 to 45) from an extensile release. These figures help to define further the structural anatomy of this region and the potential for transfer of the latissimus dorsi tendon. Cite this article: Bone Joint J 2013;95-B:517–22


The Bone & Joint Journal
Vol. 95-B, Issue 2 | Pages 199 - 205
1 Feb 2013
Robinson PM Wilson J Dalal S Parker RA Norburn P Roy BR

This study reports the clinical and sonographic outcome of arthroscopic rotator cuff repair in patients aged ≥ 70 years and aimed to determine factors associated with re-tear. A total of 69 consecutive repairs were performed in 68 patients with a mean age of 77 years (70 to 86). Constant-Murley scores were collected pre-operatively and at one year post-operatively. The integrity of the repair was assessed using ultrasound. Re-tear was detected in 20 of 62 patients (32%) assessed with ultrasound. Age at operation was significantly associated with re-tear free survival (p = 0.016). The mean pre-operative Constant score was 23 (. sd. 14), which increased to 58 (. sd. 20) at one year post-operatively (paired t-test, p < 0.001). Male gender was significantly associated with a higher score at one year (p = 0.019). We conclude that arthroscopic rotator cuff repair in patients aged ≥ 70 years is a successful procedure. The gender and age of the patient are important factors to consider when planning management. Cite this article: Bone Joint J 2013;95-B:199–205


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 10 | Pages 1403 - 1409
1 Oct 2010
Pape G Zeifang F Bruckner T Raiss P Rickert M Loew M

Fractures of the proximal humerus can lead to malalignment of the humeral head, necrosis and post-traumatic osteoarthritis. In such cases surface replacement might be a promising option. A total of 28 shoulders with glenohumeral arthritis subsequent to a fracture underwent surface replacement arthroplasty of the humeral head in patients with a mean age of 60 years (35 to 83). On the basis of the inclination of the impacted head, post-traumatic arthritis was divided into three types: type 1, an impacted fracture of the head in an anatomical position (seven cases); type 2, a valgus impacted fracture (13 cases); type 3, a varus impacted fracture (eight cases). The outcome was measured by means of the Constant score. According to the Boileau classification of the sequelae of fractures of the proximal humerus, all 28 patients had a final result of intra-capsular category 1. The mean Constant score for the 28 shoulders increased from 23.2 points (2 to 45) pre-operatively to 55.1 points (20 to 89) at a mean of 31 months (24 to 66) post-operatively. Valgus impacted fractures had significantly better results (p < 0.039). Surface replacement arthroplasty can provide good results for patients with post-traumatic osteoarthritis of the shoulder. Their use avoids post-operative complications of the humeral shaft, such as peri-prosthetic fractures. Further surgery can be undertaken more easily as the bone stock is preserved


The Bone & Joint Journal
Vol. 95-B, Issue 5 | Pages 668 - 672
1 May 2013
Abdel MP Hattrup SJ Sperling JW Cofield RH Kreofsky CR Sanchez-Sotelo J

Instability after arthroplasty of the shoulder is difficult to correct surgically. Soft-tissue procedures and revision surgery using unconstrained anatomical components are associated with a high rate of failure. The purpose of this study was to determine the results of revision of an unstable anatomical shoulder arthroplasty to a reverse design prosthesis. Between 2004 and 2007, 33 unstable anatomical shoulder arthroplasties were revised to a reverse design. The mean age of the patients was 71 years (53 to 86) and their mean follow-up was 42 months (25 to 71). The mean time to revision was 26 months (4 to 164). Pain scores improved significantly (pre-operative visual analogue scale (VAS) of 7.2 (. sd. 1.6); most recent VAS 2.2 (. sd. 1.9); p = 0.001). There was a statistically significant increase in mean active forward elevation from 40.2° (. sd. 27.3) to 97.0° (. sd. 36.2) (p = 0.001). There was no significant difference in internal (p = 0.93) or external rotation (p = 0.40). Radiological findings included notching in five shoulders (15%) and heterotopic ossification of the inferior capsular region in three (9%). At the last follow-up 31 shoulders (94%) were stable. The remaining two shoulders dislocated at 2.5 weeks and three months post-operatively, respectively. According to the Neer rating system, there were 13 excellent (40%), ten satisfactory (30%) and ten unsatisfactory results (30%). Revision of hemiarthroplasty or anatomical total shoulder replacement for instability using a reverse design prosthesis gives good short-term results. Cite this article: Bone Joint J 2013;95-B:668–72


The Bone & Joint Journal
Vol. 95-B, Issue 1 | Pages 70 - 74
1 Jan 2013
Dattani R Smith CD Patel VR

We investigated the incidence of and risk factors for venous thromboembolism (VTE) following surgery of the shoulder and elbow and assessed the role of thromboprophylaxis in upper limb surgery. All papers describing VTE after shoulder and elbow surgery published in the English language literature before 31 March 2012 were reviewed. A total of 14 papers were available for analysis, most of which were retrospective studies and case series. The incidence of VTE was 0.038% from 92 440 shoulder arthroscopic procedures, 0.52% from 42 261 shoulder replacements, and 0.64% from 4833 procedures for fractures of the proximal humerus (open reduction and internal fixation or hemiarthroplasty). The incidence following replacement of the elbow was 0.26% from 2701 procedures. Diabetes mellitus, rheumatoid arthritis and ischaemic heart disease were identified as the major risk factors. The evidence that exists on thromboprophylaxis is based on level III and IV studies, and we therefore cannot make any recommendations on prophylaxis based on the current evidence. It seems reasonable to adopt a multimodal approach that involves all patients receiving mechanical prophylaxis, with chemical prophylaxis reserved for those who are at high risk for VTE. Cite this article: Bone Joint J 2013;95-B:70–4


The Journal of Bone & Joint Surgery British Volume
Vol. 82-B, Issue 3 | Pages 409 - 412
1 Apr 2000
Kumta SM Leung PC Griffith JF Kew J Chow LTC

We describe our experience with vascularised bone grafting for the treatment of fibrous dysplasia of the upper limb in eight patients, five men and three women, aged between 17 and 36 years. The site was in the humerus in six and the radius in two. Persistent pain, progression of the lesion and pathological fracture with delayed union were the indications for surgical intervention. We used a vascularised fibular graft after curettage of the lesion. Function and radiological progress were serially monitored. Early radiological union of the graft occurred at periods ranging from 8 to 14 weeks. The mean period for reconstitution of the diameter of the bone was 14 months (12 to 18) predominantly through inductive formation of bone around the vascularised graft, which was a prominent feature in all patients. There were no recurrences and none of the grafts sustained a fracture or failed to unite. After operation function was excellent in three patients and good in five. Vascularised bone grafts provide a safe and reliable means of ensuring good continuity of bone with little risk of recurrence and failure


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 4 | Pages 511 - 516
1 Apr 2009
Yam A Fullilove S Sinisi M Fox M

We reviewed 42 consecutive children with a supination deformity of the forearm complicating severe birth lesions of the brachial plexus. The overall incidence over the study period was 6.9% (48 of 696). It was absent in those in Narakas group I (27.6) and occurred in 5.7% of group II (13 of 229), 9.6% of group III (11 of 114) and 23.4% of group IV (18 of 77). Concurrent deformities at the shoulder, elbow, wrist and hand were always present because of muscular imbalance from poor recovery of C5 and C7, inconsistent recovery of C8 and T1 and good recovery of C6. Early surgical correction improved the function of the upper limb and hand, but there was a tendency to recurrence. Pronation osteotomy placed the hand in a functional position, and increased the arc of rotation of the forearm. The supination deformity recurred in 40% (17 of 42) of those treated by pronation osteotomy alone, probably because of remodelling of the growing bone. Children should be followed up until skeletal maturity, and the parents counselled on the likelihood of multiple operations


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 8 | Pages 1054 - 1057
1 Aug 2009
Kotwal PP Khan SA

A prospective series of 32 cases with tuberculosis of the hand and wrist is presented. The mean age of the patients was 23.9 years (3 to 65), 12 had bony disease and 20 primarily soft-tissue involvement. The metacarpal of the little finger was the most commonly involved bone. Pain and swelling were the usual presenting features and discharging sinuses were seen in three cases. All patients were given anti-tubercular chemotherapy with four drugs. Operative treatment in the form of open or arthroscopic debridement, or incision and drainage of abscesses, was performed in those cases where no response was seen after eight weeks of ATT. Hand function was evaluated by the modified score of Green and O’Brien. The mean was 58.3 (25 to 80) before treatment and 90.5 (80 to 95) at the end. The mean follow-up was for 22.4 months (6 to 43). Conservative treatment was successful in 24 patients (75%). Eight who did not respond to chemotherapy within eight weeks required surgery. Although tuberculosis of hand has a varied presentation, the majority of lesions respond to conservative treatment


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 5 | Pages 627 - 632
1 May 2007
Ramamurthy C Cutler L Nuttall D Simison AJM Trail IA Stanley JK

This study identified variables which influence the outcome of surgical management on 126 ununited scaphoid fractures managed by internal fixation and non-vascular bone grafting. The site of fracture was defined by a new method: the ratio of the length of the proximal fragment to the sum of the lengths of both fragments, calculated using specific views in the plain radiographs. Bone healing occurred in 71% (89) of cases. Only the site of nonunion (p = 1 × 10. −6. ) and the delay to surgery (p = 0.001) remained significant on multivariate analysis. The effect of surgical delay on the probability of union increased as the fracture site moved proximally. A prediction model was produced by stepwise logistic regression analysis, enabling the surgeon to predict the success of surgery where the site of the nonunion and delay to surgery is known


The Journal of Bone & Joint Surgery British Volume
Vol. 84-B, Issue 1 | Pages 77 - 82
1 Jan 2002
Ikävalko M Lehto MUK Repo A Kautiainen H Hämäläinen M

We present the results of 525 primary Souter elbow arthroplasties undertaken in 406 patients between 1982 and 1997. There were 372 women and 34 men with a mean age of 57 years; 119 patients had a bilateral procedure. The elbows were affected by chronic inflammatory disease, usually rheumatoid arthritis, which had been present for a mean of 24.7 years (2 to 70). In about 30% the joints were grossly destroyed with significant loss of bone. In 179 elbows the ulnar components were metal-backed and retentive; in the remaining 346, with better bone stock, non-retentive, all-polyethylene prostheses were used. Because of complications, 108 further operations were required in 82 patients. During the early years the incidence of complications was higher. Dislocation was the indication for 30 further procedures in 26 patients. Thirty patients underwent 33 revision procedures for aseptic loosening, 12 had 29 operations because of deep infection, two for superficial infection, and 14 further operations were done for other reasons. The cumulative rate of success, without aseptic loosening, five and ten years after surgery, was 96% and 85%, respectively


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 6 | Pages 814 - 818
1 Jun 2005
Ince A Seemann K Frommelt L Katzer A Loehr JF

There are few reports in the literature of the diagnosis and treatment of the infected shoulder arthroplasty. Most deal with resection arthroplasty and two-stage exchange surgery. We present our results of one-stage exchange operation as treatment for the infected shoulder arthroplasty. Our group comprised 16 patients (ten men, six women) with 16 infected arthroplasties. By the time of follow-up, two patients had died (mean 5.8 years), two could not be located and three had already undergone revision surgery. Nine patients were thus available for clinical examination and assessment. The infections were largely caused by staphylococci, Propionibacterium species and streptococci. Two were early infections (within three months of surgery) and 14 were late infections. The mean follow-up was 5.8 years (13 months to 13.25 years) when the mean Constant-Murley score was 33.6 points and the mean University College of Los Angeles score 18.3 points. Further revision was performed in three patients. One sustained a peri-prosthetic humeral fracture, another developed an acromial pseudarthrosis after transacromial surgery and the third suffered recurrent dislocations. No patient had a recurrence of infection. A one-stage exchange procedure using antibiotic-loaded bone cement eradicated infection in all our patients and we suggest that such a procedure is at least as successful as either a resection arthroplasty or a two-stage exchange in the management of the infected shoulder arthroplasty


The Journal of Bone & Joint Surgery British Volume
Vol. 86-B, Issue 6 | Pages 848 - 855
1 Aug 2004
Gerber C Werner CML Vienne P

We treated 34 consecutive articular fractures of the proximal humerus in 33 patients with good bone quality by open reduction and internal fixation. Anatomical or nearly anatomical reduction was achieved in 30, at a mean follow-up of 63 months (25 to 131), complete or partial avascular necrosis had occurred in 12 cases (35%). Two patients subsequently underwent arthroplasty and six further patients required additional surgery. The 32 patients who did not require arthroplasty obtained a mean Constant score of 78 points or 89% of an age- and gender-matched normal score (66 points or 76% in the presence and 83 points or 96% in the absence of avascular necrosis (p < 0.0005)); 22 were painfree, and seven had mild pain and three moderate pain. The mean active anterior elevation was 156°. Internal fixation of complex fractures of the proximal humerus restored good shoulder function if avascular necrosis did not develop


The Journal of Bone & Joint Surgery British Volume
Vol. 85-B, Issue 3 | Pages 342 - 346
1 Apr 2003
Olsen BS Søjbjerg JO

This study describes the surgical technique used for reconstruction and reinforcement of the lateral collateral ligament complex in patients with posterolateral instability of the elbow and the results. A triceps tendon graft from the ipsilateral elbow which was inserted through bone tunnels and fixed with bone anchors augmented the reconstruction. The operation was performed on 18 consecutive patients with instability after an acute traumatic dislocation. The mean follow-up was 44 months (14 to 88). There were no recurrent dislocations. The elbow was stable in 14 patients; three had some minor limitation of movement. Thirteen had no or only occasional slight pain, 15 returned to their normal level of activity and 17 were satisfied with the outcome. There was only one failure


The Journal of Bone & Joint Surgery British Volume
Vol. 78-B, Issue 2 | Pages 242 - 243
1 Mar 1996
Edelson JG

A distinctive and consistent pattern of degenerative change was seen in 560 acromioclavicular joints from dry bone skeletons of subjects over 40 years of age. An appreciation of this characteristic configuration is helpful at operation or when introducing a needle into the joint


The Journal of Bone & Joint Surgery British Volume
Vol. 85-B, Issue 3 | Pages 358 - 362
1 Apr 2003
Park MJ

The movements of the carpal bones during the scaphoid shift test were evaluated radiographically in 60 wrists. The clinical results were graded according to the degree of subluxation of the scaphoid and pain on the dorsum of the wrist. Lateral radiographs at rest and under stress were taken and the relative movements of the scaphoid with respect to the radius and lunate, and the rotation of the scaphoid and lunate were calculated. Dorsal displacement of the scaphoid with respect to the radius was significantly associated with the clinical grade of subluxation. There was correlation between the amount of pain and the displacement of the scaphoid from the lunate, but not from the radius. The wrists with a painful shift test had greater relative displacement of the scaphoid from the lunate than those with painless subluxation. These observations support the view that pain associated with subluxation of the scaphoid during the shift test is a significant finding, and that radiographic analysis of the test may confirm a positive result when dynamic scaphoid instability is suspected


The Journal of Bone & Joint Surgery British Volume
Vol. 84-B, Issue 1 | Pages 73 - 76
1 Jan 2002
Park MJ

The patterns of laxity of normal wrists subjected to dorsal and volar stresses were analysed. Dorsal and volar displacement tests were carried out on both wrists of 50 subjects under image-intensifier control. Lateral projections in neutral, and dorsal and volar stress positions were taken to analyse the behaviour of the carpal bones. Varying degrees of capitolunate subluxation under dorsal and volar stress were noted. Dorsal displacement of the capitate appeared to be more prominent than volar displacement. The lunate either extended or subluxed dorsally in response to a dorsal stress, suggesting a different pattern of laxity for the radiolunate joint. These observations provide a baseline for the interpretation of dorsal and volar stress views in the symptomatic wrist


The Journal of Bone & Joint Surgery British Volume
Vol. 83-B, Issue 2 | Pages 230 - 234
1 Mar 2001
Saedén B Törnkvist H Ponzer S Höglund M

We compared the long-term outcome in 61 patients (62 fractures) treated operatively or conservatively for an acute fracture of the carpal scaphoid. A total of 30 fractures was randomised to conservative treatment using a cast and 32 to operative treatment using a Herbert bone screw. The duration of sick leave was shorter for patients treated by operation, but this was only significant in patients with blue-collar occupations. There were no differences between the groups in respect of function, radiological healing of the fracture, or carpal arthritis after follow-up at 12 years. Those managed by operation showed radiological signs of arthritis of the scaphotrapezial joint more often, but this finding did not correlate with subjective symptoms. Operative treatment of an acute fracture of the scaphoid allows early return of function and should be regarded as an alternative to conservative treatment in patients in whom immobilisation in a cast for three months is not acceptable for reasons related to sports, social life or work


The Journal of Bone & Joint Surgery British Volume
Vol. 78-B, Issue 5 | Pages 783 - 786
1 Sep 1996
Pech J Sosna A Rybka V Pokorný D

Arthrodesis of the wrist is a standard operation which is indicated for severe rheumatoid arthritis in which destruction is too advanced for more conservative procedures, or after failure of previous surgery. We have developed an L-shaped plate designed for this purpose. It provides rigid internal fixation with the wrist in the neutral position and utilises bone grafts obtained from the distal ulna and the carpal bones. We have carried out 29 successful fusions between 1992 and 1995. In all 29 patients synovectomy and resection of the head of the ulna were performed; 11 also had reconstruction of ruptured extensor tendons. All the patients obtained bony union, pain relief and improved function


The Journal of Bone & Joint Surgery British Volume
Vol. 80-B, Issue 4 | Pages 620 - 623
1 Jul 1998
Mohammed NSE

A new technique of shoulder fusion is presented using a posterior approach. After removal of the articular cartilage, a Rush pin is introduced from the spine of the scapula, through the glenoid into the medullary canal of the humerus. This is supplemented by tension-band wiring from the acromion to the neck of the humerus and a muscle pedicle graft attached to the acromion. A shoulder spica is applied for four to six weeks. Four patients with injuries to the upper brachial plexus and 14 with paralysis of the upper arm due to anterior poliomyelitis have been followed for three years. One of the 18 patients developed nonunion; she had removed her own cast prematurely. This method of fixation provides high shear resistance and low axial stiffness without deforming plastically. It does not affect bone growth in young patients, is effective in patients with osteoporosis, and gives a high rate of union


The Journal of Bone & Joint Surgery British Volume
Vol. 80-B, Issue 4 | Pages 614 - 619
1 Jul 1998
Baksi DP

From 1984 to 1995, 68 ankylosed elbows and 11 which were unstable after trauma were replaced in India by Baksi sloppy hinge prostheses. The mean age of the patients was 28.6 years (17 to 70) and the mean follow-up 9.6 years (2 to 13.5). Of the 68 ankylosed elbows, 59 (87%) regained a mean arc of painless movement of 88.5° (27 to 115). The mean improvement of supination was 24° and of pronation 16.5°. There were 54 good results (80%), eight fair and three poor. There were two complete failures due to infection, and one due to a broken humeral stem. Of the 11 unstable elbows, the nine with good results had a mean arc of 125° (15 to 140) of painless stable movement, with a mean improvement in supination of 26° and of pronation of 19.5°. There was one fair result and one failure due to loosening with subsequent late infection. There were significant complications in 14 cases with infection in seven and aseptic loosening in four. Patients with loosening or late removal of the prosthesis often retained reasonably stable elbow movement because periprosthetic fibrosis had connected the approximated bone ends, and muscle balance had been restored


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 10 | Pages 1382 - 1389
1 Oct 2012
Sewell MD Kang SN Al-Hadithy N Higgs DS Bayley I Falworth M Lambert SM

There is little information about the management of peri-prosthetic fracture of the humerus after total shoulder replacement (TSR). This is a retrospective review of 22 patients who underwent a revision of their original shoulder replacement for peri-prosthetic fracture of the humerus with bone loss and/or loose components. There were 20 women and two men with a mean age of 75 years (61 to 90) and a mean follow-up 42 months (12 to 91): 16 of these had undergone a previous revision TSR. Of the 22 patients, 12 were treated with a long-stemmed humeral component that bypassed the fracture. All their fractures united after a mean of 27 weeks (13 to 94). Eight patients underwent resection of the proximal humerus with endoprosthetic replacement to the level of the fracture. Two patients were managed with a clam-shell prosthesis that retained the original components. The mean Oxford shoulder score (OSS) of the original TSRs before peri-prosthetic fracture was 33 (14 to 48). The mean OSS after revision for fracture was 25 (9 to 31). Kaplan-Meier survival using re-intervention for any reason as the endpoint was 91% (95% confidence interval (CI) 68 to 98) and 60% (95% CI 30 to 80) at one and five years, respectively.

There were two revisions for dislocation of the humeral head, one open reduction for modular humeral component dissociation, one internal fixation for nonunion, one trimming of a prominent screw and one re-cementation for aseptic loosening complicated by infection, ultimately requiring excision arthroplasty. Two patients sustained nerve palsies.

Revision TSR after a peri-prosthetic humeral fracture associated with bone loss and/or loose components is a salvage procedure that can provide a stable platform for elbow and hand function. Good rates of union can be achieved using a stem that bypasses the fracture. There is a high rate of complications and function is not as good as with the original replacement.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 11 | Pages 1448 - 1454
1 Nov 2012
Ng CY Watts AC

Bone loss involving articular surface is a challenging problem faced by the orthopaedic surgeon. In the hand and wrist, there are articular defects that are amenable to autograft reconstruction when primary fixation is not possible. In this article, the surgical techniques and clinical outcomes of articular reconstructions in the hand and wrist using non-vascularised osteochondral autografts are reviewed.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 11 | Pages 1540 - 1545
1 Nov 2012
Reigstad O Lütken T Grimsgaard C Bolstad B Thorkildsen R Røkkum M

The Motec cementless modular metal-on-metal ball-and-socket wrist arthroplasty was implanted in 16 wrists with scaphoid nonunion advanced collapse (SNAC; grades 3 or 4) and 14 wrists with scapholunate advanced collapse (SLAC) in 30 patients (20 men) with severe (grades 3 or 4) post-traumatic osteoarthritis of the wrist. The mean age of the patients was 52 years (31 to 71). All prostheses integrated well radiologically. At a mean follow-up of 3.2 years (1.1 to 6.1) no luxation or implant breakage occurred. Two wrists were converted to an arthrodesis for persistent pain. Loosening occurred in one further wrist at five years post-operatively. The remainder demonstrated close bone–implant contact. The clinical results were good, with markedly decreased Disabilities of the Arm Shoulder and Hand (DASH) and pain scores, and increased movement and grip strength. No patient used analgesics and most had returned to work.

Good short-term function was achieved using this wrist arthroplasty in a high-demand group of patients with post-traumatic osteoarthritis.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 12 | Pages 1660 - 1665
1 Dec 2012
Megerle K Bertel D Germann G Lehnhardt M Hellmich S

The purpose of this study was to assess the clinical and radiological outcomes of dorsal intercarpal ligament capsulodesis for the treatment of static scapholunate instability at a minimum follow-up of four years. A total of 59 patients who underwent capsulodesis for this condition were included in a retrospective analysis after a mean of 8.25 years (4.3 to 12). A total of eight patients underwent a salvage procedure at a mean of 2.33 years (0.67 to 7.6) and were excluded. The mean range of extension/flexion was 88° (15° to 135°) and of ulnar/radial deviation was 38° (0° to 75°) at final follow-up. The mean Disabilities of the Arm Shoulder and Hand (DASH) score and Mayo wrist scores were 28 (0 to 85) and 61 (0 to 90), respectively. After significant improvement immediately post-operatively (p < 0.001 and p = 0.001, respectively), the mean scapholunate and radiolunate angles deteriorated to 70° (40° to 90°) and 8° (-15° to 25°), respectively, at final follow-up, which were not significantly different from their pre-operative values (p = 0.6 and p = 0.4, respectively). The mean carpal height index decreased significantly from 1.53 (1.38 to 1.65) to 1.48 (1.29 to 1.65) indicating progressive carpal collapse (p < 0.001); 40 patients (78%) had radiological evidence of degenerative arthritis.

Capsulodesis did not maintain carpal reduction over time. Although the consequent ongoing scapholunate instability resulted in early arthritic degeneration, most patients had acceptable long-term function of the wrist.


Bone & Joint Research
Vol. 2, Issue 7 | Pages 132 - 139
1 Jul 2013
Ketola S Lehtinen J Rousi T Nissinen M Huhtala H Konttinen YT Arnala I

Objectives

To report the five-year results of a randomised controlled trial examining the effectiveness of arthroscopic acromioplasty in the treatment of stage II shoulder impingement syndrome.

Methods

A total of 140 patients were randomly divided into two groups: 1) supervised exercise programme (n = 70, exercise group); and 2) arthroscopic acromioplasty followed by a similar exercise programme (n = 70, combined treatment group).


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 6 | Pages 721 - 728
1 Jun 2012
Goudie EB Murray IR Robinson CM

Dislocation of the shoulder may occur during seizures in epileptics and other patients who have convulsions. Following the initial injury, recurrent instability is common owing to a tendency to develop large bony abnormalities of the humeral head and glenoid and a susceptibility to further seizures. Assessment is difficult and diagnosis may be missed, resulting in chronic locked dislocations with protracted morbidity. Many patients have medical comorbidities, and successful treatment requires a multidisciplinary approach addressing the underlying seizure disorder in addition to the shoulder pathology. The use of bony augmentation procedures may have improved the outcomes after surgical intervention, but currently there is no evidence-based consensus to guide treatment. This review outlines the epidemiology and pathoanatomy of seizure-related instability, summarising the currently-favoured options for treatment, and their results.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 6 | Pages 805 - 810
1 Jun 2012
Flinkkilä T Kaisto T Sirniö K Hyvönen P Leppilahti J

We assessed the short- to mid-term survival of metallic press-fit radial head prostheses in patients with radial head fractures and acute traumatic instability of the elbow.

The medical records of 42 patients (16 males, 26 females) with a mean age of 56 years (23 to 85) with acute unstable elbow injuries, including a fracture of the radial head requiring metallic replacement of the radial head, were reviewed retrospectively. Survival of the prosthesis was assessed from the radiographs of 37 patients after a mean follow-up of 50 months (12 to 107). The functional results of 31 patients were assessed using range-of-movement, Mayo elbow performance score (MEPS), Disabilities of the Arm, Shoulder and Hand (DASH) score and the RAND 36-item health survey.

At the most recent follow-up 25 prostheses were still well fixed, nine had been removed because of loosening, and three remained implanted but were loose. The mean time from implantation to loosening was 11 months (2 to 24). Radiolucent lines that developed around the prosthesis before removal were mild in three patients, moderate in one and severe in five. Range of movement parameters and mass grip strength were significantly lower in the affected elbow than in the unaffected side. The mean MEPS score was 86 (40 to 100) and the mean DASH score was 23 (0 to 81). According to RAND-36 scores, patients had more pain and lower physical function scores than normal population values.

Loosening of press-fit radial head prostheses is common, occurs early, often leads to severe osteolysis of the proximal radius, and commonly requires removal of the prosthesis.


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 9 | Pages 1240 - 1246
1 Sep 2011
Melis B DeFranco M Lädermann A Molé D Favard L Nérot C Maynou C Walch G

Radiological changes and differences between cemented and uncemented components of Grammont reverse shoulder arthroplasties (DePuy) were analysed at a mean follow-up of 9.6 years (8 to 12). Of 122 reverse shoulder arthroplasties implanted in five shoulder centres between 1993 and 2000, a total of 68 (65 patients) were available for study. The indications for reversed shoulder arthroplasty were cuff tear arthropathy in 48 shoulders, revision of shoulder prostheses of various types in 11 and massive cuff tear in nine. The development of scapular notching, bony scapular spur formation, heterotopic ossification, glenoid and humeral radiolucencies, stem subsidence, radiological signs of stress shielding and resorption of the tuberosities were assessed on standardised true anteroposterior and axillary radiographs.

A scapular notch was observed in 60 shoulders (88%) and was associated with the superolateral approach (p = 0.009). Glenoid radiolucency was present in 11 (16%), bony scapular spur and/or ossifications in 51 (75%), and subsidence of the stem and humeral radiolucency in more than three zones were present in three (8.8%) and in four (11.8%) of 34 cemented components, respectively, and in one (2.9%) and two (5.9%) of 34 uncemented components, respectively. Radiological signs of stress shielding were significantly more frequent with uncemented components (p < 0.001), as was resorption of the greater (p < 0.001) and lesser tuberosities (p = 0.009).


Bone & Joint Research
Vol. 1, Issue 9 | Pages 210 - 217
1 Sep 2012
Walton JR Murrell GAC

Objectives

The aim of this study was to determine whether there is any significant difference in temporal measurements of pain, function and rates of re-tear for arthroscopic rotator cuff repair (RCR) patients compared with those patients undergoing open RCR.

Methods

This study compared questionnaire- and clinical examination-based outcomes over two years or longer for two series of patients who met the inclusion criteria: 200 open RCR and 200 arthroscopic RCR patients. All surgery was performed by a single surgeon.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 1 | Pages 16 - 22
1 Jan 2012
Popovic D King GJW

In light of the growing number of elderly osteopenic patients with distal humeral fractures, we discuss the history of their management and current trends. Under most circumstances operative fixation and early mobilisation is the treatment of choice, as it gives the best results. The relative indications for and results of total elbow replacement versus internal fixation are discussed.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 5 | Pages 577 - 583
1 May 2012
Smith CD Guyver P Bunker TD

The outcome of an anatomical shoulder replacement depends on an intact rotator cuff. In 1981 Grammont designed a novel large-head reverse shoulder replacement for patients with cuff deficiency. Such has been the success of this replacement that it has led to a rapid expansion of the indications. We performed a systematic review of the literature to evaluate the functional outcome of each indication for the reverse shoulder replacement. Secondary outcome measures of range of movement, pain scores and complication rates are also presented.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 12 | Pages 1666 - 1669
1 Dec 2012
Gulotta LV Choi D Marinello P Wright T Cordasco FA Craig EV Warren RF

Reverse total shoulder replacement (RTSR) depends on adequate deltoid function for a successful outcome. However, the anterior deltoid and/or axillary nerve may be damaged due to prior procedures or injury. The purpose of this study was to determine the compensatory muscle forces required for scapular plane elevation following RTSR when the anterior deltoid is deficient. The soft tissues were removed from six cadaver shoulders, except for tendon attachments. After implantation of the RTSR, the shoulders were mounted on a custom-made shoulder simulator to determine the mean force in each muscle required to achieve 30° and 60° of scapular plane elevation. Two conditions were tested: 1) Control with an absent supraspinatus and infraspinatus; and 2) Control with anterior deltoid deficiency. Anterior deltoid deficiency resulted in a mean increase of 195% in subscapularis force at 30° when compared with the control (p = 0.02). At 60°, the subscapularis force increased a mean of 82% (p < 0.001) and the middle deltoid force increased a mean of 26% (p = 0.04).

Scapular plane elevation may still be possible following an RTSR in the setting of anterior deltoid deficiency. When the anterior deltoid is deficient, there is a compensatory increase in the force required by the subscapularis and middle deltoid. Attempts to preserve the subscapularis, if present, might maximise post-operative function.


Bone & Joint Research
Vol. 1, Issue 7 | Pages 158 - 166
1 Jul 2012
Dean BJF Franklin SL Carr AJ

Introduction

The pathogenesis of rotator cuff disease (RCD) is complex and not fully understood. This systematic review set out to summarise the histological and molecular changes that occur throughout the spectrum of RCD.

Methods

We conducted a systematic review of the scientific literature with specific inclusion and exclusion criteria.


Bone & Joint Research
Vol. 1, Issue 5 | Pages 78 - 85
1 May 2012
Entezari V Della Croce U DeAngelis JP Ramappa AJ Nazarian A Trechsel BL Dow WA Stanton SK Rosso C Müller A McKenzie B Vartanians V Cereatti A

Objectives

Cadaveric models of the shoulder evaluate discrete motion segments using the glenohumeral joint in isolation over a defined trajectory. The aim of this study was to design, manufacture and validate a robotic system to accurately create three-dimensional movement of the upper body and capture it using high-speed motion cameras.

Methods

In particular, we intended to use the robotic system to simulate the normal throwing motion in an intact cadaver. The robotic system consists of a lower frame (to move the torso) and an upper frame (to move an arm) using seven actuators. The actuators accurately reproduced planned trajectories. The marker setup used for motion capture was able to determine the six degrees of freedom of all involved joints during the planned motion of the end effector.


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 7 | Pages 937 - 941
1 Jul 2011
Bae J Oh J Chon C Oh C Hwang J Yoon Y

We evaluated the biomechanical properties of two different methods of fixation for unstable fractures of the proximal humerus. Biomechanical testing of the two groups, locking plate alone (LP), and locking plate with a fibular strut graft (LPSG), was performed using seven pairs of human cadaveric humeri. Cyclical loads between 10 N and 80 N at 5 Hz were applied for 1 000 000 cycles. Immediately after cycling, an increasing axial load was applied at a rate of displacement of 5 mm/min. The displacement of the construct, maximum failure load, stiffness and mode of failure were compared.

The displacement was significantly less in the LPSG group than in the LP group (p = 0.031). All maximum failure loads and measures of stiffness in the LPSG group were significantly higher than those in the LP group (p = 0.024 and p = 0.035, respectively). In the LP group, varus collapse and plate bending were seen. In the LPSG group, the humeral head cut out and the fibular strut grafts fractured. No broken plates or screws were seen in either group.

We conclude that strut graft augmentation significantly increases both the maximum failure load and the initial stiffness of this construct compared with a locking plate alone.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 9 | Pages 1253 - 1259
1 Sep 2012
Sewell MD Higgs DS Al-Hadithy N Falworth M Bayley I Lambert SM

Scapulothoracic fusion (STF) for painful winging of the scapula in neuromuscular disorders can provide effective pain relief and functional improvement, but there is little information comparing outcomes between patients with dystrophic and non-dystrophic conditions. We performed a retrospective review of 42 STFs in 34 patients with dystrophic and non-dystrophic conditions using a multifilament trans-scapular, subcostal cable technique supported by a dorsal one-third semi-tubular plate. There were 16 males and 18 females with a mean age of 30 years (15 to 75) and a mean follow-up of 5.0 years (2.0 to 10.6). The mean Oxford shoulder score improved from 20 (4 to 39) to 31 (4 to 48). Patients with non-dystrophic conditions had lower overall functional scores but achieved greater improvements following STF. The mean active forward elevation increased from 59° (20° to 90°) to 97° (30° to 150°), and abduction from 51° (10° to 90°) to 83° (30° to 130°) with a greater range of movement achieved in the dystrophic group. Revision fusion for nonunion was undertaken in five patients at a mean time of 17 months (7 to 31) and two required revision for fracture. There were three pneumothoraces, two rib fractures, three pleural effusions and six nonunions. The main risk factors for nonunion were smoking, age and previous shoulder girdle surgery.

STF is a salvage procedure that can provide good patient satisfaction in 82% of patients with both dystrophic and non-dystrophic pathologies, but there was a relatively high failure rate (26%) when poor outcomes were analysed. Overall function was better in patients with dystrophic conditions which correlated with better range of movement; however, patients with non-dystrophic conditions achieved greater functional improvement.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 1 | Pages 86 - 92
1 Jan 2012
Jeon IH Sanchez-Sotelo J Zhao K An KN Morrey BM

We undertook this study to determine the minimum amount of coronoid necessary to stabilise an otherwise intact elbow joint. Regan–Morrey types II and III, plus medial and lateral oblique coronoid fractures, collectively termed type IV fractures, were simulated in nine fresh cadavers. An electromagnetic tracking system defined the three-dimensional stability of the ulna relative to the humerus. The coronoid surface area accounts for 59% of the anterior articulation. Alteration in valgus, internal and external rotation occurred only with a type III coronoid fracture, accounting for 68% of the coronoid and 40% of the entire articular surface. A type II fracture removed 42% of the coronoid articulation and 25% of the entire articular surface but was associated with valgus and external rotational changes only when the radial head was removed, thereby removing 67% of the articular surface.

We conclude that all type III fractures, as defined here, are unstable, even with intact ligaments and a radial head. However, a type II deficiency is stable unless the radial head is removed. Our study suggests that isolated medial-oblique or lateral-oblique fractures, and even a type II fracture with intact ligaments and a functional radial head, can be clinically stable, which is consistent with clinical observation.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 6 | Pages 799 - 804
1 Jun 2012
Hems TEJ Mahmood F

We reviewed 101 patients with injuries of the terminal branches of the infraclavicular brachial plexus sustained between 1997 and 2009. Four patterns of injury were identified: 1) anterior glenohumeral dislocation (n = 55), in which the axillary and ulnar nerves were most commonly injured, but the axillary nerve was ruptured in only two patients (3.6%); 2) axillary nerve injury, with or without injury to other nerves, in the absence of dislocation of the shoulder (n = 20): these had a similar pattern of nerve involvement to those with a known dislocation, but the axillary nerve was ruptured in 14 patients (70%); 3) displaced proximal humeral fracture (n = 15), in which nerve injury resulted from medial displacement of the humeral shaft: the fracture was surgically reduced in 13 patients; and 4) hyperextension of the arm (n = 11): these were characterised by disruption of the musculocutaneous nerve. There was variable involvement of the median and radial nerves with the ulnar nerve being least affected.

Surgical intervention is not needed in most cases of infraclavicular injury associated with dislocation of the shoulder. Early exploration of the nerves should be considered in patients with an axillary nerve palsy without dislocation of the shoulder and for musculocutaneous nerve palsy with median and/or radial nerve palsy. Urgent operation is needed in cases of nerve injury resulting from fracture of the humeral neck to relieve pressure on nerves.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 3 | Pages 348 - 352
1 Mar 2012
Higgs ZCJ Danks BA Sibinski M Rymaszewski LA

The use of passive stretching of the elbow after arthrolysis is controversial. We report the results of open arthrolysis in 81 patients. Prospectively collected outcome data with a minimum follow-up of one year were analysed. All patients had sustained an intra-articular fracture initially and all procedures were performed by the same surgeon under continuous brachial plexus block anaesthesia and with continuous passive movement (CPM) used post-operatively for two to three days. CPM was used to maintain the movement achieved during surgery and passive stretching was not used at any time. A senior physiotherapist assessed all the patients at regular intervals. The mean range of movement (ROM) improved from 69° to 109° and the function and pain of the upper limb improved from 32 to 16 and from 20 to 10, as assessed by the Disabilities of the Arm Shoulder and Hand score and a visual analogue scale, respectively. The greatest improvement was obtained in the stiffest elbows: nine patients with a pre-operative ROM < 30° achieved a mean post-operative ROM of 92° (55° to 125°). This study demonstrates that in patients with a stiff elbow after injury, good results may be obtained after open elbow arthrolysis without using passive stretching during rehabilitation.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 3 | Pages 353 - 358
1 Mar 2012
Kim SM Park MJ Kang HJ Choi YL Lee JJ

We investigated the clinical response to arthroscopic synovectomy in patients with undifferentiated chronic monoarthritis (UCMA) of the wrist. Arthroscopic synovectomy was performed on 20 wrists in 20 patients with UCMA of the wrist who had not responded to non-steroidal anti-inflammatory drugs. The mean duration of symptoms at the time of surgery was 4.3 months (3 to 7) and the mean follow-up was 51.8 months (24 to 94). Inflamed synovium was completely removed from the radiocarpal, midcarpal and distal radioulnar joints using more portals than normal. After surgery, nine patients had early remission of synovitis and 11 with uncontrolled synovitis received antirheumatic medication. Overall, there was significant improvement in terms of pain relief, range of movement and Mayo score. Radiological deterioration was seen in five patients who were diagnosed as having rheumatoid arthritis during the follow-up period. Lymphoid follicles and severe lymphocyte infiltration were seen more often in synovial biopsies from patients with uncontrolled synovitis.

These results suggest that arthroscopic synovectomy provides pain relief and functional improvement, and allows rapid resolution of synovitis in about half of patients with UCMA of the wrist.


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 2 | Pages 210 - 216
1 Feb 2011
Young A Walch G Boileau P Favard L Gohlke F Loew M Molé D

We report the long-term clinical and radiological outcomes of the Aequalis total shoulder replacement with a cemented all-polyethylene flat-back keeled glenoid component implanted for primary osteoarthritis between 1991 and 2003 in nine European centres. A total of 226 shoulders in 210 patients were retrospectively reviewed at a mean of 122.7 months (61 to 219) or at revision. Clinical outcome was assessed using the Constant score, patient satisfaction score and range of movement. Kaplan-Meier survivorship analysis was performed with glenoid revision for loosening and radiological glenoid loosening (sd) as endpoints. The Constant score was found to improve from a mean of 26.8 (sd 10.3) pre-operatively to 57.6 (sd 20.0) post-operatively (p < 0.001). Active forward flexion improved from a mean of 85.3° (sd 27.4) pre-operatively to 125° (sd 37.3) postoperatively (p < 0.001). External rotation improved from a mean of 7° (sd 6.5) pre-operatively to 30.3° (sd 21.8°) post-operatively (p < 0.001). Survivorship with revision of the glenoid component as the endpoint was 99.1% at five years, 94.5% at ten years and 79.4% at 15 years. Survivorship with radiological loosening as the endpoint was 99.1% at five years, 80.3% at ten years and 33.6% at 15 years.

Younger patient age and the curettage technique for glenoid preparation correlated with loosening. The rate of glenoid revision and radiological loosening increased with duration of follow-up, but not until a follow-up of five years. Therefore, we recommend that future studies reporting radiological outcomes of new glenoid designs should report follow-up of at least five to ten years.


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 1 | Pages 57 - 61
1 Jan 2011
Naveed MA Kitson J Bunker TD

The combination of an irreparable tear of the rotator cuff and destructive arthritis of the shoulder joint may cause severe pain, disability and loss of independence in the aged. Standard anatomical shoulder replacements depend on a functioning rotator cuff, and hence may fail in the presence of tears in the cuff. Many designs of non-anatomical constrained or semi-constrained prostheses have been developed for cuff tear arthropathy, but have proved unsatisfactory and were abandoned. The DePuy Delta III reverse prosthesis, designed by Grammont, medialises and stabilises the centre of rotation of the shoulder joint and has shown early promise. This study evaluated the mid-term clinical and radiological results of this arthroplasty in a consecutive series of 50 shoulders in 43 patients with a painful pseudoparalysis due to an irreparable cuff tear and destructive arthritis, performed over a period of seven years by a single surgeon. A follow-up of 98% was achieved, with a mean duration of 39 months (8 to 81). The mean age of the patients at the time of surgery was 81 years (59 to 95). The female to male ratio was 5:1. During the seven years, six patients died of natural causes. The clinical outcome was assessed using the American Shoulder and Elbow score, the Oxford Shoulder Score and the Short-form 36 score. A radiological review was performed using the Sirveaux score for scapular notching.

The mean American Shoulder and Elbow score was 19 (95% confidence interval (CI) 14 to 23) pre-operatively, and 65 (95% CI 48 to 82) (paired t-test, p < 0.001) at final follow-up. The mean Oxford score was 44 (95% CI 40 to 51) pre-operatively and 23 (95% CI 18 to 28) (paired t-test, p < 0.001) at final follow-up.

The mean maximum elevation improved from 55° pre-operatively to 105° at final follow-up. There were seven complications during the whole series, although only four patients required further surgery.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 2 | Pages 222 - 226
1 Feb 2012
Rodrigues-Pinto R Freitas D Costa LD Sousa R Trigueiros M Lemos R Silva C Oliveira A

Radial osteotomy is currently advocated for patients with Lichtman’s stages II and IIIA of Kienböck’s disease; its place in the treatment of patients with stage IIIB disease remains controversial. The purpose of this study was to evaluate the medium-term results of this procedure and to compare the outcome in patients with stage IIIB disease and those with earlier stages (II and IIIA). A total of 18 patients (18 osteotomies) were evaluated both clinically and radiologically at a mean follow-up of 10.3 years (4 to 18). Range of movement, grip strength and pain improved significantly in all patients; the functional score (Nakamura Scoring System (NSSK)) was high and self-reported disability (Disabilities of Arm, Shoulder and Hand questionnaire) was low at the final follow-up in all patients evaluated. Patients with stage IIIB disease, however, had a significantly lower grip strength, lower NSSK scores and higher disability than those in less advanced stages. Radiological progression of the disease was not noted in either group, despite the stage. Radial osteotomy seems effective in halting the progression of disease and improving symptoms in stages II, IIIA and IIIB. Patients with less advanced disease should be expected to have better clinical results.


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 7 | Pages 970 - 974
1 Jul 2010
Foruria AM Sperling JW Ankem HK Oh LS Cofield RH

This study was performed to review the safety and outcome of total shoulder replacements in patients who are ≥ 80 years of age. A total of 50 total shoulder replacements in 44 patients at a mean age of 82 years (80 to 89) were studied. Their health and shoulder status, the operation and post-operative course were analysed, including pain, movement, patient satisfaction, medical and surgical complications, radiographs, the need for revision surgery, and implant and patient survival. A total of 27 patients had an ASA classification of III or IV and medical abnormalities were common. Of the 13 shoulders with bony deficiency of the glenoid, nine required grafting. The duration of hospital stay was prolonged and blood transfusions were common. There were no peri-operative deaths. The mean follow-up was for 5.5 years (2 to 12). Pain was significantly reduced (p < 0.001) and movement improved in active elevation and both external and internal rotation (p < 0.001). Using the Neer scale for assessing outcome, 40 (80%) shoulders had an excellent or satisfactory result. There were medical or surgical complications in 17 cases. Four shoulders developed radiological evidence of loosened glenoid components, and three of these had a poor outcome. Three other shoulders required revision, two for instability. By the time of this review 39 of the patients had died from unrelated causes at a mean of 7.5 years (0.8 to 16.4) after surgery.

Total shoulder replacement is a relatively effective treatment in this elderly group of patients. However, there is a requirement for more intense patient care in the peri-operative period, and non-fatal medical or surgical complications are common. Most of these elderly patients will have a comfortable functional shoulder for the rest of their lives.


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 9 | Pages 1273 - 1277
1 Sep 2010
Larson AN Adams RA Morrey BF

Between 1996 and 2008, nine patients with severe post-traumatic arthritis underwent revision of a failed interposition arthroplasty of the elbow with a further interposition procedure using an allograft of tendo Achillis at a mean of 5.6 years (0.7 to 13.1) after the initial procedure. There were eight men and one woman with a mean age of 47 years (36 to 56).

The mean follow-up was 4.7 years (2 to 8). The mean Mayo Elbow Performance score improved from 49 (15 to 65) pre-operatively to 73 (55 to 95) (p = 0.04). The mean Disability of the Arm, Shoulder and Hand score was 26 (7 to 42). One patient was unavailable for clinical follow-up and one underwent total elbow replacement three months post-operatively. Of the remaining patients, one had an excellent, two had good, three fair and one a poor result. Subjectively, five of the nine patients were satisfied. Four continued manual labour.

Revision interposition arthroplasty is an option for young, active patients with severe post-traumatic arthritis who require both mobility and durability of the elbow.


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 6 | Pages 713 - 719
1 Jun 2011
Duckworth AD Ring D McQueen MM

A suspected fracture of the scaphoid remains difficult to manage despite advances in knowledge and imaging methods. Immobilisation and restriction of activities in a young and active patient must be balanced against the risks of nonunion associated with an undiagnosed and undertreated fracture of the scaphoid.

The assessment of diagnostic tests for a suspected fracture of the scaphoid must take into account two important factors. First, the prevalence of true fractures among suspected fractures is low, which greatly reduces the probability that a positive test will correspond with a true fracture, as false positives are nearly as common as true positives. This situation is accounted for by Bayesian statistics. Secondly, there is no agreed reference standard for a true fracture, which necessitates the need for an alternative method of calculating diagnostic performance characteristics, based upon a statistical method which identifies clinical factors tending to associate (latent classes) in patients with a high probability of fracture.

The most successful diagnostic test to date is MRI, but in low-prevalence situations the positive predictive value of MRI is only 88%, and new data have documented the potential for false positive scans. The best strategy for improving the diagnosis of true fractures among suspected fractures of the scaphoid may well be to develop a clinical prediction rule incorporating a set of demographic and clinical factors which together increase the pre-test probability of a fracture of the scaphoid, in addition to developing increasingly sophisticated radiological tests.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 1 | Pages 1 - 9
1 Jan 2012
Robinson CM Seah KTM Chee YH Hindle P Murray IR

Frozen shoulder is commonly encountered in general orthopaedic practice. It may arise spontaneously without an obvious predisposing cause, or be associated with a variety of local or systemic disorders. Diagnosis is based upon the recognition of the characteristic features of the pain, and selective limitation of passive external rotation. The macroscopic and histological features of the capsular contracture are well-defined, but the underlying pathological processes remain poorly understood. It may cause protracted disability, and imposes a considerable burden on health service resources. Most patients are still managed by physiotherapy in primary care, and only the more refractory cases are referred for specialist intervention. Targeted therapy is not possible and treatment remains predominantly symptomatic. However, over the last ten years, more active interventions that may shorten the clinical course, such as capsular distension arthrography and arthroscopic capsular release, have become more popular.

This review describes the clinical and pathological features of frozen shoulder. We also outline the current treatment options, review the published results and present our own treatment algorithm.


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 2 | Pages 224 - 229
1 Feb 2010
Arora R Lutz M Zimmermann R Krappinger D Niederwanger C Gabl M

We report the use of a free vascularised iliac bone graft in the treatment of 21 patients (19 men and 2 women) with an avascular nonunion of the scaphoid in which conventional bone grafting had previously failed. The mean age of the patients was 32 years (23 to 46) and the dominant wrist was affected in 14. The mean interval from fracture to the vascularised bone grafting was 39 months (9 to 62). Pre-operative MRI showed no contrast enhancement in the proximal fragment in any patient. Fracture union was assessed radiologically or with CT scans if the radiological appearances were inconclusive.

At a mean follow-up of 5.6 years (2 to 11) union was obtained in 16 patients. The remaining five patients with a persistent nonunion continued to experience pain, reduced grip strength and limited range of wrist movement. In the successfully treated patients the grip strength and range of movement did not recover to match the uninjured side.

Prevention of progressive carpal collapse, the absence of donor site morbidity, good subjective results and pain relief, justifies this procedure in the treatment of recalcitrant nonunion of the scaphoid.


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 7 | Pages 975 - 979
1 Jul 2010
Camp SJ Carlstedt T Casey ATH

Intraspinal re-implantation after traumatic avulsion of the brachial plexus is a relatively new technique. Three different approaches to the spinal cord have been described to date, namely the posterior scapular, anterolateral interscalenic multilevel oblique corpectomy and the pure lateral. We describe an anatomical study of the pure lateral approach, based on our clinical experience and studies on cadavers.


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 3 | Pages 387 - 392
1 Mar 2010
Kasten P Pape G Raiss P Bruckner T Rickert M Zeifang F Loew M

We have investigated the mid-term outcome of total shoulder replacement using a keeled cemented glenoid component and a modern cementing technique with regard to the causes of failure and loosening of the components.

Between 1997 and 2003 we performed 96 total shoulder replacements on 88 patients, 24 men and 64 women with a mean age of 69.7 years (31 to 82). The minimum follow-up was five years and at the time of review 87 shoulders (77 patients) were examined at a mean follow-up of 89.1 months (60 to 127). Cumulative survival curves were generated with re-operations (accomplished and planned), survivorship of the proshesis, loosening of the glenoid (defined as tilt > 5° or subsidence > 5 mm), the presence of radiolucent lines and a Constant score of < 30 as the endpoints.

There were two re-operations not involving revision of the implants and the survival rate of the prosthesis was 100.0% for the follow-up period, with an absolute Constant score of > 30 as the endpoint the survival rate was 98%. Radiological glenoid loosening was 9% after five years, and 33% after nine years. There was an incidence of 8% of radiolucent lines in more than three of six zones in the immediate post-operative period, of 37.0% after the first year which increased to 87.0% after nine years. There was no correlation between the score of Boileau and the total Constant score at the latest follow-up, but there was correlation between glenoid loosening and pain (p = 0.001).

We found that total shoulder replacement had an excellent mid-term survivorship and clinical outcome. The surgical and cementing techniques were related to the decrease in radiolucent lines around the glenoid compared with earlier studies. One concern, however, was the fact that radiolucent lines increased over time and there was a rate of glenoid loosening of 9% after five years and 33% after nine years. This suggests that the design of the glenoid component, and the implantation and cementing techniques may need further improvement.


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 10 | Pages 1397 - 1402
1 Oct 2010
Nada AN Debnath UK Robinson DA Jordan C

We describe the clinical outcome of a technique of surgical augmentation of chronic massive tears of the rotator cuff using a polyester ligament (Dacron) in 21 symptomatic patients (14 men, seven women) with a mean age of 66.5 years (55.0 to 85.0). All patients had MRI and arthroscopic evidence of chronic massive tears. The clinical outcome was assessed using the Constant and Murley and patient satisfaction scores at a mean follow-up of 36 months (30 to 46).

The polyester ligament (500 mm × 10 mm) was passed into the joint via the portal of Neviaser, medial to the tear through healthy cuff. The two ends of the ligament holding the cuff were passed through tunnels made in the proximal humerus at the footprint of the insertion of the cuff. The ligament was tied with a triple knot over the humeral cortex.

All the patients remained free from pain (p < 0.001) with improvement in function (p < 0.001) and range of movement (p < 0.001). The mean pre-operative and post-operative Constant scores were 46.7 (39.0 to 61.0) and 85.4 (52.0 to 96.0), respectively (p < 0.001). The mean patient satisfaction score was 90%. There were two failures, one due to a ruptured ligament after one year and the other due to deep-seated infection. The MR scan at the final follow-up confirmed intact and thickened bands in 15 of 17 patients.

This technique of augmentation gives consistent relief from pain with improved shoulder movement in patients with symptomatic massive tears of the rotator cuff.


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 9 | Pages 1247 - 1252
1 Sep 2011
Sinha A Edwin J Sreeharsha B Bhalaik V Brownson P

This study investigated the anatomical relationship between the clavicle and its adjacent vascular structures, in order to define safe zones, in terms of distance and direction, for drilling of the clavicle during osteosynthesis using a plate and screws following a fracture. We used reconstructed three-dimensional CT arteriograms of the head, neck and shoulder region. The results have enabled us to divide the clavicle into three zones based on the proximity and relationship of the vascular structures adjacent to it. The results show that at the medial end of the clavicle the subclavian vessels are situated behind it, with the vein intimately related to it. In some scans the vein was opposed to the posterior cortex of the clavicle. At the middle one-third of the clavicle the artery and vein are a mean of 17.02 mm (5.4 to 26.8) and 12.45 mm (5 to 26.1) from the clavicle, respectively, and at a mean angle of 50° (12 to 80) and 70° (38 to 100), respectively, to the horizontal. At the lateral end of the clavicle the artery and vein are at mean distances of 63.4 mm (46.8 to 96.5) and 75.67 mm (50 to 109), respectively.

An appreciation of the information gathered from this study will help minimise the risk of inadvertent iatrogenic vascular injury during plating of the clavicle.


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 7 | Pages 942 - 948
1 Jul 2011
Chaudhury S Holland C Vollrath F Carr AJ

This study reports the application of a novel method for quantitatively determining differences in the mechanical properties of healthy and torn rotator cuff tissues. In order to overcome problems of stress risers at the grip-tendon interface that can obscure mechanical measurements of small tendons, we conducted our investigation using dynamic shear analysis.

Rotator cuff tendon specimens were obtained from 100 patients during shoulder surgery. They included 82 differently sized tears and 18 matched controls. We subjected biopsy samples of 3 mm in diameter to oscillatory deformation under compression using dynamic shear analysis. The storage modulus (G’) was calculated as an indicator of mechanical integrity.

Normal tendons had a significantly higher storage modulus than torn tendons, indicating that torn tendons are mechanically weaker than normal tendons (p = 0.003). Normal tendons had a significantly higher mean shear modulus than tendons with massive tears (p < 0.01).

Dynamic shear analysis allows the determination of shear mechanical properties of small tissue specimens obtained intra-operatively that could not be studied by conventional methods of tensile testing. These methods could be employed to investigate other musculoskeletal tissues. This pilot study provides some insight into mechanisms that might contribute to the failure of repair surgery, and with future application could help direct the most appropriate treatment for specific rotator cuff tears.


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 6 | Pages 817 - 822
1 Jun 2010
Beekman PDA Katusic D Berghs BM Karelse A De Wilde L

We retrospectively reviewed 11 consecutive patients with an infected reverse shoulder prosthesis. Patients were assessed clinically and radiologically, and standard laboratory tests were carried out. Peroperative samples showed Propionbacterium acnes in seven, coagulase-negative Staphylococcus in five, methicillin-resistant staphylococcus aureus in one and Escherichia coli in one. Two multibacterial and nine monobacterial infections were seen. Post-operatively, patients were treated with intravenous cefazolin for at least three days and in all antibiotic therapy was given for at least three months. Severe pain (3 of 11) or severe limitation of function (3 of 11) are not necessarily seen. A fistula was present in eight, but function was not affected. All but one patient were considered free of infection after one-stage revision at a median follow-up of 24 months, and without antibiotic treatment for a minimum of six months. One patient had a persistent infection despite a second staged revision, but is now free of infection with a spacer. Complications included posterior dislocation in one, haematoma in one and a clavicular fracture in one. At the most recent follow-up the median post-operative Constant-Murley score was 55, 6% adjusted for age, gender and dominance.

A one-stage revision arthroplasty reduces the cost and duration of treatment. It is reliable in eradicating infection and good functional outcomes can be achieved.


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 4 | Pages 535 - 539
1 Apr 2010
Cazeneuve JF Cristofari D

We have previously described the short-term outcome of the use of reverse shoulder arthroplasty in the treatment of acute complex proximal humeral fractures in the elderly. We now report the clinical and radiological outcome of 36 fractures at a mean of 6.6 years (1 to 16). Previously, at a mean follow-up of 6 years (1 to 12) the mean Constant score was 58.5; this was reduced to 53 points with the further follow-up. A total of 23 patients (63%) had radiological evidence of loosening of the glenoid component. Nevertheless, only one patient had aseptic loosening of the baseplate at 12 years’ follow-up.

The reduction in the mean Constant score with longer follow-up and the further development of scapular notching is worrying.

New developments in design, bearing surfaces and surgical technique, and further follow-up, will determine whether reverse shoulder arthroplasty has a place in the management of complex proximal humeral fractures in the elderly.


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 12 | Pages 1594 - 1600
1 Dec 2009
Khan A Bunker TD Kitson JB

There are no long-term published results on the survival of a third-generation cemented total shoulder replacement. We describe a clinical and radiological study of the Aequalis total shoulder replacement for a minimum of ten years. Between September 1996 and May 1998, 39 consecutive patients underwent a primary cemented total shoulder replacement using this prosthesis. Data were collected prospectively on all patients each year, for a minimum of ten years, or until death or failure of the prosthesis. At a follow-up of at least ten years, 12 patients had died with the prosthesis intact and two had emigrated, leaving 25 available for clinical review. Of these, 13 had rheumatoid arthritis and 12 osteoarthritis. One refused radiological review leaving 24 with fresh radiographs.

Survivorship at ten years was 100% for the humeral component and 92% for the glenoid component. The incidence of lucent lines was low. No humeral component was thought to be at risk and only two glenoid components. The osteoarthritic group gained a mean 65° in forward flexion and their Constant score improved by a mean 41.4 points (13 to 55). The rheumatoid group gained a mean of 24° in flexion and their Constant score improved by 29.4 points. This difference may have been due to failure of the rotator cuff in 75% of the patients with rheumatoid arthritis.

Thus a third-generation total shoulder replacement gives an excellent result in patients with osteoarthritis and an intact rotator cuff. Patients with rheumatoid arthritis have a 75% risk of failure of the rotator cuff at ten years.


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 2 | Pages 235 - 241
1 Feb 2010
van der Lugt JCT Valstar ER Witvoet-Braam SW Nelissen RGHH

Mechanical loosening which begins with early-onset migration of the prosthesis is the major reason for failure of the Souter-Strathclyde elbow replacement. In a prospective study of 18 Souter-Strathclyde replacements we evaluated the patterns of migration using roentgen stereophotogrammetric analysis. We had previously reported the short-term results after a follow-up of two years which we have now extended to a mean follow-up of 8.2 years (1 to 11.3). Migration was assessed along the co-ordinal axes and overall micromovement was expressed as the maximum total point movement. The alignment of the prosthesis and the presence of radiolucent lines were examined on conventional standardised radiographs.

All the humeral components showed increased and variable patterns of migration at the extended follow-up and four humeral components were revised. The maximum total point movement at two years in the revised prostheses was 1.8 mm (sd 1.0) and in the non-revised 0.7 mm (sd 0.5, p = 0.01). Most humeral components migrated into external rotation resulting in an anterior and varus tilt. The ulnar components remained stable.