header advert
Results 1 - 100 of 713
Results per page:
The Bone & Joint Journal
Vol. 105-B, Issue 10 | Pages 1123 - 1130
1 Oct 2023
Donnan M Anderson N Hoq M Donnan L

Aims. The aim of this study was to investigate the agreement in interpretation of the quality of the paediatric hip ultrasound examination, the reliability of geometric and morphological assessment, and the relationship between these measurements. Methods. Four investigators evaluated 60 hip ultrasounds and assessed their quality based the standard plane of Graf et al. They measured geometric parameters, described the morphology of the hip, and assigned the Graf grade of dysplasia. They analyzed one self-selected image and one randomly selected image from the ultrasound series, and repeated the process four weeks later. The intra- and interobserver agreement, and correlations between various parameters were analyzed. Results. In the assessment of quality, there a was moderate to substantial intraobserver agreement for each element investigated, but interobserver agreement was poor. Morphological features showed weak to moderate agreement across all parameters but improved to significant when responses were reduced. The geometric measurements showed nearly perfect agreement, and the relationship between them and the morphological features showed a dose response across all parameters with moderate to substantial correlations. There were strong correlations between geometric measurements. The Graf classification showed a fair to moderate interobserver agreement, and moderate to substantial intraobserver agreement. Conclusion. This investigation into the reliability of the interpretation of hip ultrasound scans identified the difficulties in defining what is a high-quality ultrasound. We confirmed that geometric measurements are reliably interpreted and may be useful as a further measurement of quality. Morphological features are generally poorly interpreted, but a simpler binary classification considerably improves agreement. As there is a clear dose response relationship between geometric and morphological measurements, the importance of morphology in the diagnosis of hip dysplasia should be questioned. Cite this article: Bone Joint J 2023;105-B(10):1123–1130


Bone & Joint Research
Vol. 10, Issue 12 | Pages 759 - 766
1 Dec 2021
Nicholson JA Oliver WM MacGillivray TJ Robinson CM Simpson AHRW

Aims. The aim of this study was to establish a reliable method for producing 3D reconstruction of sonographic callus. Methods. A cohort of ten closed tibial shaft fractures managed with intramedullary nailing underwent ultrasound scanning at two, six, and 12 weeks post-surgery. Ultrasound capture was performed using infrared tracking technology to map each image to a 3D lattice. Using echo intensity, semi-automated mapping was performed to produce an anatomical 3D representation of the fracture site. Two reviewers independently performed 3D reconstructions and kappa coefficient was used to determine agreement. A further validation study was undertaken with ten reviewers to estimate the clinical application of this imaging technique using the intraclass correlation coefficient (ICC). Results. Nine of the ten patients achieved union at six months. At six weeks, seven patients had bridging callus of ≥ one cortex on the 3D reconstruction and when present all achieved union. Compared to six-week radiographs, no bridging callus was present in any patient. Of the three patients lacking sonographic bridging callus, one went onto a nonunion (77.8% sensitive and 100% specific to predict union). At 12 weeks, nine patients had bridging callus at ≥ one cortex on 3D reconstruction (100%-sensitive and 100%-specific to predict union). Presence of sonographic bridging callus on 3D reconstruction demonstrated excellent reviewer agreement on ICC at 0.87 (95% confidence interval 0.74 to 0.96). Conclusion. 3D fracture reconstruction can be created using multiple ultrasound images in order to evaluate the presence of bridging callus. This imaging modality has the potential to enhance the usability and accuracy of identification of early fracture healing. Cite this article: Bone Joint Res 2021;10(12):759–766


The Bone & Joint Journal
Vol. 106-B, Issue 7 | Pages 751 - 758
1 Jul 2024
Yaxier N Zhang Y Song J Ning B

Aims. Given the possible radiation damage and inaccuracy of radiological investigations, particularly in children, ultrasound and superb microvascular imaging (SMI) may offer alternative methods of evaluating new bone formation when limb lengthening is undertaken in paediatric patients. The aim of this study was to assess the use of ultrasound combined with SMI in monitoring new bone formation during limb lengthening in children. Methods. In this retrospective cohort study, ultrasound and radiograph examinations were performed every two weeks in 30 paediatric patients undergoing limb lengthening. Ultrasound was used to monitor new bone formation. The number of vertical vessels and the blood flow resistance index were compared with those from plain radiographs. Results. We categorized the new bone formation into three stages: stage I (early lengthening), in which there was no obvious callus formation on radiographs and ultrasound; stage II (lengthening), in which radiographs showed low-density callus formation with uneven distribution and three sub-stages could be identified on ultrasound: in Ia punctate callus was visible; in IIb there was linear callus formation which was not yet connected and in IIc there was continuous linear callus. In stage III (healing), the bone ends had united, the periosteum was intact, and the callus had disappeared, as confirmed on radiographs, indicating healed bone. A progressive increase in the number of vertical vessels was noted in the early stages, peaking during stages IIb and IIc, followed by a gradual decline (p < 0.001). Delayed healing involved patients with a prolonged stage IIa or those who regressed to stage IIa from stages IIb or IIc during lengthening. Conclusion. We found that the formation of new bone in paediatric patients undergoing limb lengthening could be reliably evaluated using ultrasound when combined with the radiological findings. This combination enabled an improved assessment of the prognosis, and adjustments to the lengthening protocol. While SMI offered additional insights into angiogenesis within the new bone, its role primarily contributed to the understanding of the microvascular environment rather than directly informing adjustments of treatment. Cite this article: Bone Joint J 2024;106-B(7):751–758


Bone & Joint Research
Vol. 8, Issue 7 | Pages 304 - 312
1 Jul 2019
Nicholson JA Tsang STJ MacGillivray TJ Perks F Simpson AHRW

Objectives. The aim of this study was to review the current evidence and future application for the role of diagnostic and therapeutic ultrasound in fracture management. Methods. A review of relevant literature was undertaken, including articles indexed in PubMed with keywords “ultrasound” or “sonography” combined with “diagnosis”, “fracture healing”, “impaired fracture healing”, “nonunion”, “microbiology”, and “fracture-related infection”. Results. The use of ultrasound in musculoskeletal medicine has expanded rapidly over the last two decades, but the diagnostic use in fracture management is not routinely practised. Early studies have shown the potential of ultrasound as a valid alternative to radiographs to diagnose common paediatric fractures, to detect occult injuries in adults, and for rapid detection of long bone fractures in the resuscitation setting. Ultrasound has also been shown to be advantageous in the early identification of impaired fracture healing; with the advent of 3D image processing, there is potential for wider adoption. Detection of implant-related infection can be improved by ultrasound mediated sonication of microbiology samples. The use of therapeutic ultrasound to promote union in the management of acute fractures is currently a controversial topic. However, there is strong in vitro evidence that ultrasound can stimulate a biological effect with potential clinical benefit in established nonunions, which supports the need for further investigation. Conclusion. Modern ultrasound image processing has the potential to replace traditional imaging modalities in several areas of trauma practice, particularly in the early prediction of impaired fracture healing. Further understanding of the therapeutic application of ultrasound is required to understand and identify the use in promoting fracture healing. Cite this article: J. A. Nicholson, S. T. J. Tsang, T. J. MacGillivray, F. Perks, A. H. R. W. Simpson. What is the role of ultrasound in fracture management? Diagnosis and therapeutic potential for fractures, delayed unions, and fracture-related infection. Bone Joint Res 2019;8:304–312. DOI: 10.1302/2046-3758.87.BJR-2018-0215.R2


The Bone & Joint Journal
Vol. 98-B, Issue 4 | Pages 498 - 503
1 Apr 2016
Mahadevan D Attwal M Bhatt R Bhatia M

Aims. The objective of this double-blind randomised controlled trial was to assess whether ultrasound guidance improved the efficacy of corticosteroid injections for Morton’s neuroma (MN). . Patients and Methods. In all, 50 feet (40 patients) were recruited for this study but five feet were excluded due to the patients declining further participation. The mean age of the remaining 36 patients (45 feet) was 57.8 years (standard deviation (. sd. ) 12.9) with a female preponderance (33F:12M). All patients were followed-up for 12 months. Treatment was randomised to an ultrasound guided (Group A) or non-ultrasound guided (Group B) injection of 40 mg triamcinolone acetonide and 2 ml 1% lignocaine, following ultrasound confirmation of the diagnosis. . Results. The mean visual analogue score for pain improved significantly in both groups (Group A – from 64 mm, . sd. 25 mm to 29 mm, . sd. 27; Group B – from 69 mm, . sd. 23 mm to 37 mm, . sd. 25) with no statistical difference between them at all time-points. The failure rate within 12 months of treatment was 11/23 (48%) and 12/22 (55%) in Groups A and B, respectively (p = 0.458). The improvement in Manchester Oxford Foot Questionnaire Index and patient satisfaction favoured Group A in the short-term (three months) that almost reached statistical significance (p = 0.059 and 0.066 respectively). However, this difference was not observed beyond three months. . Conclusion. This study has shown that ultrasound guidance did not demonstrably improve the efficacy of corticosteroid injections in patients with MN. Take home message: In the presence of a clear diagnosis of MN, a trained clinician who understands the forefoot anatomy may perform an injection without ultrasound guidance with good and safe results. Cite this article: Bone Joint J 2016;98-B:498–503


The Bone & Joint Journal
Vol. 104-B, Issue 2 | Pages 283 - 289
1 Feb 2022
Cerbasi S Bernasconi A Balato G Dimitri F Zingaretti O Orabona G Pascarella R Mariconda M

Aims. The aims of this study were to assess the pre- and postoperative incidence of deep vein thrombosis (DVT) using routine duplex Doppler ultrasound (DUS), to assess the incidence of pulmonary embolism (PE) using CT angiography, and to identify the factors that predict postoperative DVT in patients with a pelvic and/or acetabular fracture. Methods. All patients treated surgically for a pelvic and/or acetabular fracture between October 2016 and January 2020 were enrolled into this prospective single-centre study. The demographic, medical, and surgical details of the patients were recorded. DVT screening of the lower limbs was routinely performed using DUS before and at six to ten days after surgery. CT angiography was used in patients who were suspected of having PE. Age-adjusted univariate and stepwise multiple logistic regression analysis were used to determine the association between explanatory variables and postoperative DVT. Results. A total of 191 patients were included. A DVT was found preoperatively in 12 patients (6.3%), of which six were proximal. A postoperative DVT was found in 42 patients (22%), of which 27 were proximal. Eight patients (4.2%) had a PE, which was secondary to a DVT in three. None of the 12 patients in whom a vena cava filter was implanted prophylactically had a PE. Multivariate logistic regression analysis indicated that the association with the need for spinal surgery (odds ratio (OR) 19.78 (95% confidence interval (CI) 1.12 to 348.08); p = 0.041), intramedullary nailing of a long bone fracture (OR 4.44 (95% CI 1.05 to 18.86); p = 0.043), an operating time > two hours (OR 3.28 (95% CI 1.09 to 9.88); p = 0.035), and additional trauma surgery (OR 3.1 (95% CI 1.03 to 9.45); p = 0.045) were statistically the most relevant independent predictors of a postoperative DVT. Conclusion. The acknowledgement of the risk factors for the development of a DVT and their weight is crucial to set a threshold for the index of suspicion for this diagnosis by medical staff. We suggest the routine use of the DUS screening for DVT in patients with a pelvic and/or acetabular fracture before and six to ten days after surgery. Cite this article: Bone Joint J 2022;104-B(2):283–289


The Bone & Joint Journal
Vol. 99-B, Issue 11 | Pages 1526 - 1532
1 Nov 2017
Tarride JE Hopkins RB Blackhouse G Burke N Bhandari M Johal H Guyatt GH Busse JW

Aims. This 501-patient, multi-centre, randomised controlled trial sought to establish the effect of low-intensity, pulsed, ultrasound (LIPUS) on tibial shaft fractures managed with intramedullary nailing. We conducted an economic evaluation as part of this trial. Patients and Methods. Data for patients’ use of post-operative healthcare resources and time taken to return to work were collected and costed using publicly available sources. Health-related quality of life, assessed using the Health Utilities Index Mark-3 (HUI-3), was used to derive quality-adjusted life years (QALYs). Costs and QALYs were compared between LIPUS and control (a placebo device) from a payer and societal perspective using non-parametric bootstrapping. All costs are reported in 2015 Canadian dollars unless otherwise stated. Results. With a cost per device of $3,995, the mean cost was significantly higher for patients treated with LIPUS versus placebo from a payer (mean increase = $3647, 95% confidence interval (CI) $3244 to $4070; p < 0.001) or a societal perspective (mean increase = $3425, 95% CI $1568 to $5283; p < 0.001). LIPUS did not provide a significant benefit in terms of QALYs gained (mean difference = 0.023 QALYs, 95% CI -0.035 to 0.069; p = 0.474). Incremental cost-effectiveness ratios of LIPUS compared with placebo were $155 433/QALY from a payer perspective and $146 006/QALY from a societal perspective. Conclusion. At the current price, LIPUS is not cost-effective for fresh tibial fractures managed with intramedullary nailing. Cite this article: Bone Joint J 2017;99-B:1526–32


The Bone & Joint Journal
Vol. 99-B, Issue 4 | Pages 494 - 502
1 Apr 2017
Simpson AHRW Keenan G Nayagam S Atkins RM Marsh D Clement ND

Aims. The aim of this double-blind prospective randomised controlled trial was to assess whether low intensity pulsed ultrasound (LIPUS) accelerated or enhanced the rate of bone healing in adult patients undergoing distraction osteogenesis. Patients and Methods. A total of 62 adult patients undergoing limb lengthening or bone transport by distraction osteogenesis were randomised to treatment with either an active (n = 32) or a placebo (n = 30) ultrasound device. A standardised corticotomy was performed in the proximal tibial metaphysis and a circular Ilizarov frame was used in all patients. The rate of distraction was also standardised. The primary outcome measure was the time to removal of the frame after adjusting for the length of distraction in days/cm for both the per protocol (PP) and the intention-to-treat (ITT) groups. The assessor was blinded to the form of treatment. A secondary outcome was to identify covariates affecting the time to removal of the frame. Results. There was no difference in the time to removal of the frame between the PP (difference in favour of the control group was 10.1 days/cm, 95% confidence interval (CI) -3.2 to 23.4, p = 0.054) or ITT (difference 5.0 days/cm, 95% CI -8.2 to 18.21, p = 0.226) groups. The smoking status was the only covariate which increased the time to removal of the frame (hazard ratio 0.47, 95% CI 0.22 to 0.97, p = 0.042). Conclusion. LIPUS does not influence the rate of bone healing in patients who undergo distraction osteogenesis. Smoking may influence bone healing. . Cite this article: Bone Joint J 2017;99-B:494–502


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 11 | Pages 1534 - 1539
1 Nov 2012
Karataglis D Papadopoulos P Boutsiadis A Fotiadou A Ditsios K Hatzokos I Christodoulou A

This study evaluates the position of the long head of biceps tendon using ultrasound following simple tenotomy, in patients with arthroscopically repaired rotator cuff tears. In total, 52 patients with a mean age of 60.7 years (45 to 75) underwent arthroscopic repair of the rotator cuff and simple tenotomy of the long head of biceps tendon. At two years post-operatively, ultrasound revealed that the tendon was inside the bicipital groove in 43 patients (82.7%) and outside in nine (17.3%); in six of these it was lying just outside the groove and in the remaining three (5.8%) it was in a remote position with a positive Popeye Sign. A dynamic ultrasound scan revealed that the tenotomised tendons had adhered to the surrounding tissues (autotenodesis).The initial condition of the tendon influenced its final position (p < 0.0005). The presence of a Popeye sign was statistically influenced by the pre-operative co-existence of supraspinatus and subscapularis tears (p < 0.0001). It appears that the natural history of the tenotomised long head of biceps tendon is to tenodese itself inside or just outside the bicipital groove, while its pre-operative condition and coexistent subscapularis tears play a significant role in the occurrence of a Popeye sign


The Bone & Joint Journal
Vol. 105-B, Issue 3 | Pages 247 - 253
1 Mar 2023
Pakarinen O Ponkilainen V Uimonen M Haapanen M Helenius I Kuitunen I

Aims. To analyze whether the addition of risk-based criteria to clinical examination-based selective ultrasound screening would increase the rates of early detected cases of developmental dysplasia of the hip (DDH) and decrease the rate of late detected cases. Methods. A systematic review with meta-analysis was performed. The initial search was performed in the PubMed, Scopus, and Web of Science databases in November 2021. The following search terms were used: (hip) AND (ultrasound) AND (luxation or dysplasia) AND (newborn or neonate or congenital). Results. A total of 25 studies were included. In 19 studies, newborns were selected for ultrasound based on both risk factors and clinical examination. In six studies, newborns were selected for ultrasound based on only clinical examination. We did not find evidence indicating that there are differences in the incidence of early- and late-detected DDH, or in the incidence of nonoperatively treated DDH between the risk-based and clinical examination-based groups. The pooled incidence of operatively treated DDH was slightly lower in the risk-based group (0.5 (95% confidence interval (CI) 0.3 to 0.7)) compared with the clinical examination group (0.9 per 1,000 newborns, (95% CI 0.7 to 1.0)). Conclusion. The use of risk factors in conjunction with clinical examination in the selective ultrasound screening of DDH might lead to fewer operatively treated cases of DDH. However, more studies are needed before stronger conclusions can be drawn. Cite this article: Bone Joint J 2023;105-B(3):247–253


Bone & Joint Open
Vol. 3, Issue 11 | Pages 913 - 923
28 Nov 2022
Hareendranathan AR Wichuk S Punithakumar K Dulai S Jaremko J

Aims. Studies of infant hip development to date have been limited by considering only the changes in appearance of a single ultrasound slice (Graf’s standard plane). We used 3D ultrasound (3DUS) to establish maturation curves of normal infant hip development, quantifying variation by age, sex, side, and anteroposterior location in the hip. Methods. We analyzed 3DUS scans of 519 infants (mean age 64 days (6 to 111 days)) presenting at a tertiary children’s hospital for suspicion of developmental dysplasia of the hip (DDH). Hips that did not require ultrasound follow-up or treatment were classified as ‘typically developing’. We calculated traditional DDH indices like α angle (α. SP. ), femoral head coverage (FHC. SP. ), and several novel indices from 3DUS like the acetabular contact angle (ACA) and osculating circle radius (OCR) using custom software. Results. α angle, FHC, and ACA indices increased and OCR decreased significantly by age in the first four months, mean α. SP. rose from 62.2° (SD 5.7°) to 67.3° (SD 5.2°) (p < 0.001) in one- to eight- and nine- to 16-week-old infants, respectively. Mean α. SP. and mean FHC. SP. were significantly, but only slightly, lower in females than in males. There was no statistically significant difference in DDH indices observed between left and right hip. All 3DUS indices varied significantly between anterior and posterior section of the hip. Mean 3D indices of α angle and FHC were significantly lower anteriorly than posteriorly: α. Ant. = 58.2° (SD 6.1°), α. Post. = 63.8° (SD 6.3°) (p < 0.001), FHC. Ant. = 43.0 (SD 7.4), and FHC. Post. = 55.4° (SD 11.2°) (p < 0.001). Acetabular rounding measured byOCR indices was significantly greater in the anterior section of the hip (p < 0.001). Conclusion. We used 3DUS to show that hip shape and normal growth pattern vary significantly between anterior and posterior regions, by magnitudes similar to age-related changes. This highlights the need for careful selection of the Graf plane during 2D ultrasound examination. Whole-joint evaluation by obtaining either 3DUS or manual ‘sweep’ video images provides more comprehensive DDH assessment. Cite this article: Bone Jt Open 2022;3(11):913–923


The Bone & Joint Journal
Vol. 105-B, Issue 2 | Pages 198 - 208
1 Feb 2023
Cheok T Smith T Wills K Jennings MP Rawat J Foster B

Aims. We investigated the prevalence of late developmental dysplasia of the hip (DDH), abduction bracing treatment, and surgical procedures performed following the implementation of universal ultrasound screening versus selective ultrasound screening programmes. Methods. A systematic search of PubMed, Embase, The Cochrane Library, OrthoSearch, and Web of Science from the date of inception of each database until 27 March 2022 was performed. The primary outcome of interest was the prevalence of late detection of DDH, diagnosed after three months. Secondary outcomes of interest were the prevalence of abduction bracing treatment and surgical procedures performed in childhood for dysplasia. Only studies describing the primary outcome of interest were included. Results. A total of 31 studies were identified, of which 13 described universal screening and 20 described selective screening. Two studies described both. The prevalence of late DDH was 0.10 per 1,000 live births (95% confidence interval (CI) 0.00 to 0.39) in the universal screening group and 0.45 per 1,000 live births (95% CI 0.31 to 0.61) in the selective screening group. Abduction bracing treatment was performed on 55.54 per 1,000 live births (95% CI 24.46 to 98.15) in the universal screening group versus 0.48 per 1,000 live births (95% CI 0.07 to 1.13) in the selective screening group. Both the universal and selective screening groups had a similar prevalence of surgical procedures in childhood for dysplasia being performed (0.48 (95% CI 0.32 to 0.63) vs 0.49 (95% CI 0.31 to 0.71) per 1,000 live births, respectively). Conclusion. Universal screening showed a trend towards lower prevalence of late DDH compared to selective screening. However, it was also associated with a significant increase in the prevalence of abduction bracing without a significant reduction in the prevalence of surgical procedures in childhood for dysplasia being performed. High-quality studies comparing both treatment methods are required, in addition to studies into the natural history of missed DDH. Cite this article: Bone Joint J 2023;105-B(2):198–208


Bone & Joint Research
Vol. 10, Issue 2 | Pages 113 - 121
1 Feb 2021
Nicholson JA Oliver WM MacGillivray TJ Robinson CM Simpson AHRW

Aims. To evaluate if union of clavicle fractures can be predicted at six weeks post-injury by the presence of bridging callus on ultrasound. Methods. Adult patients managed nonoperatively with a displaced mid-shaft clavicle were recruited prospectively. Ultrasound evaluation of the fracture was undertaken to determine if sonographic bridging callus was present. Clinical risk factors at six weeks were used to stratify patients at high risk of nonunion with a combination of Quick Disabilities of the Arm, Shoulder and Hand questionnaire (QuickDASH) ≥ 40, fracture movement on examination, or absence of callus on radiograph. Results. A total of 112 patients completed follow-up at six months with a nonunion incidence of 16.7% (n = 18/112). Sonographic bridging callus was detected in 62.5% (n = 70/112) of the cohort at six weeks post-injury. If present, union occurred in 98.6% of the fractures (n = 69/70). If absent, nonunion developed in 40.5% of cases (n = 17/42). The sensitivity to predict union with sonographic bridging callus at six weeks was 73.4% and the specificity was 94.4%. Regression analysis found that failure to detect sonographic bridging callus at six weeks was associated with older age, female sex, simple fracture pattern, smoking, and greater fracture displacement (Nagelkerke R. 2. = 0.48). Of the cohort, 30.4% (n = 34/112) had absent sonographic bridging callus in addition to one or more of the clinical risk factors at six weeks that predispose to nonunion. If one was present the nonunion rate was 35%, 60% with two, and 100% when combined with all three. Conclusion. Ultrasound combined with clinical risk factors can accurately predict fracture healing at six weeks following a displaced midshaft clavicle fracture. Cite this article: Bone Joint Res 2021;10(2):113–121


The Bone & Joint Journal
Vol. 104-B, Issue 9 | Pages 1081 - 1088
1 Sep 2022
Behman AL Bradley CS Maddock CL Sharma S Kelley SP

Aims. There is no consensus regarding optimum timing and frequency of ultrasound (US) for monitoring response to Pavlik harness (PH) treatment in developmental dysplasia of the hip (DDH). The purpose of our study was to determine if a limited-frequency hip US assessment had an adverse effect on treatment outcomes compared to traditional comprehensive US monitoring. Methods. This study was a single-centre noninferiority randomized controlled trial. Infants aged under six months whose hips were reduced and centred in the harness at initiation of treatment (stable dysplastic or subluxable), or initially decentred (subluxated or dislocated) but reduced and centred within four weeks of PH treatment, were randomized to our current standard US monitoring protocol (every clinic visit) or to a limited-frequency US protocol (US only at end of treatment). Groups were compared based on α angle and femoral head coverage at the end of PH treatment, acetabular indices, and International Hip Dysplasia Institute (IHDI) grade on one-year follow-up radiographs. Results. Overall, 100 patients were included; 42 patients completed the standard protocol (SP) and 40 completed the limited protocol (LP). There was no significant difference in mean right α angle at the end of treatment (SP 70.0° (SD 3.2°) ; LP 68.7° (SD 2.9°); p = 0.033), nor on the left (SP 69.0° (SD 3.5°); LP 68.1° (SD 3.3°); p = 0.128). There was no significant difference in mean right acetabular index at follow-up (SP 23.1° (SD 4.3°); LP 22.0° (SD 4.1°); p = 0.129), nor on the left (SP 23.3° (SD 4.2°); LP 22.8° (SD 3.9°); p = 0.284). All hips had femoral head coverage of > 50% at end of treatment, and all were IHDI grade 1 at follow-up. In addition, the LP group underwent a 60% reduction in US use once stable. Conclusion. Our study supports reducing the frequency of US assessment during PH treatment of DDH once a hip is reduced and centred. Cite this article: Bone Joint J 2022;104-B(9):1081–1088


Bone & Joint Research
Vol. 13, Issue 7 | Pages 332 - 341
5 Jul 2024
Wang T Yang C Li G Wang Y Ji B Chen Y Zhou H Cao L

Aims. Although low-intensity pulsed ultrasound (LIPUS) combined with disinfectants has been shown to effectively eliminate portions of biofilm in vitro, its efficacy in vivo remains uncertain. Our objective was to assess the antibiofilm potential and safety of LIPUS combined with 0.35% povidone-iodine (PI) in a rat debridement, antibiotics, and implant retention (DAIR) model of periprosthetic joint infection (PJI). Methods. A total of 56 male Sprague-Dawley rats were established in acute PJI models by intra-articular injection of bacteria. The rats were divided into four groups: a Control group, a 0.35% PI group, a LIPUS and saline group, and a LIPUS and 0.35% PI group. All rats underwent DAIR, except for Control, which underwent a sham procedure. General status, serum biochemical markers, weightbearing analysis, radiographs, micro-CT analysis, scanning electron microscopy of the prostheses, microbiological analysis, macroscope, and histopathology evaluation were performed 14 days after DAIR. Results. The group with LIPUS and 0.35% PI exhibited decreased levels of serum biochemical markers, improved weightbearing scores, reduced reactive bone changes, absence of viable bacteria, and decreased inflammation compared to the Control group. Despite the greater antibiofilm activity observed in the PI group compared to the LIPUS and saline group, none of the monotherapies were successful in preventing reactive bone changes or eliminating the infection. Conclusion. In the rat model of PJI treated with DAIR, LIPUS combined with 0.35% PI demonstrated stronger antibiofilm potential than monotherapy, without impairing any local soft-tissue. Cite this article: Bone Joint Res 2024;13(7):332–341


Bone & Joint Open
Vol. 3, Issue 11 | Pages 885 - 893
14 Nov 2022
Goshima K Sawaguchi T Horii T Shigemoto K Iwai S

Aims. To evaluate whether low-intensity pulsed ultrasound (LIPUS) accelerates bone healing at osteotomy sites and promotes functional recovery after open-wedge high tibial osteotomy (OWHTO). Methods. Overall, 90 patients who underwent OWHTO without bone grafting were enrolled in this nonrandomized retrospective study, and 45 patients treated with LIPUS were compared with 45 patients without LIPUS treatment in terms of bone healing and functional recovery postoperatively. Clinical evaluations, including the pain visual analogue scale (VAS) and Japanese Orthopaedic Association (JOA) score, were performed preoperatively as well as six weeks and three, six, and 12 months postoperatively. The progression rate of gap filling was evaluated using anteroposterior radiographs at six weeks and three, six, and 12 months postoperatively. Results. The pain VAS and JOA scores significantly improved after OWHTO in both groups. Although the LIPUS group had better pain scores at six weeks and three months postoperatively, there were no significant differences in JOA score between the groups. The lateral hinge united at six weeks postoperatively in 34 (75.6%) knees in the control group and in 33 (73.3%) knees in the LIPUS group. The progression rates of gap filling in the LIPUS group were 8.0%, 15.0%, 27.2%, and 46.0% at six weeks and three, six, and 12 months postoperatively, respectively, whereas in the control group at the same time points they were 7.7%, 15.2%, 26.3%, and 44.0%, respectively. There were no significant differences in the progression rate of gap filling between the groups. Conclusion. The present study demonstrated that LIPUS did not promote bone healing and functional recovery after OWHTO with a locking plate. The routine use of LIPUS after OWHTO was not recommended from the results of our study. Cite this article: Bone Jt Open 2022;3(11):885–893


The Bone & Joint Journal
Vol. 103-B, Issue 6 Supple A | Pages 81 - 86
1 Jun 2021
Mahfouz MR Abdel Fatah EE Johnson JM Komistek RD

Aims. The objective of this study is to assess the use of ultrasound (US) as a radiation-free imaging modality to reconstruct 3D anatomy of the knee for use in preoperative templating in knee arthroplasty. Methods. Using an US system, which is fitted with an electromagnetic (EM) tracker that is integrated into the US probe, allows 3D tracking of the probe, femur, and tibia. The raw US radiofrequency (RF) signals are acquired and, using real-time signal processing, bone boundaries are extracted. Bone boundaries and the tracking information are fused in a 3D point cloud for the femur and tibia. Using a statistical shaping model, the patient-specific surface is reconstructed by optimizing bone geometry to match the point clouds. An accuracy analysis was conducted for 17 cadavers by comparing the 3D US models with those created using CT. US scans from 15 users were compared in order to examine the effect of operator variability on the output. Results. The results revealed that the US bone models were accurate compared with the CT models (root mean squared error (RM)S: femur, 1.07 mm (SD 0.15); tibia, 1.02 mm (SD 0.13). Additionally, femoral landmarking proved to be accurate (transepicondylar axis: 1.07° (SD 0.65°); posterior condylar axis: 0.73° (SD 0.41°); distal condylar axis: 0.96° (SD 0.89°); medial anteroposterior (AP): 1.22 mm (SD 0.69); lateral AP: 1.21 mm (SD 1.02)). Tibial landmarking errors were slightly higher (posterior slope axis: 1.92° (SD 1.31°); and tubercle axis: 1.91° (SD 1.24°)). For implant sizing, 90% of the femora and 60% of the tibiae were sized correctly, while the remainder were only one size different from the required implant size. No difference was observed between moderate and skilled users. Conclusion. The 3D US bone models were proven to be closely matched compared with CT and suitable for preoperative planning. The 3D US is radiation-free and offers numerous clinical opportunities for bone visualization rapidly during clinic visits, to enable preoperative planning with implant sizing. There is potential to extend its application to 3D dynamic ligament balancing, and intraoperative registration for use with robots and navigation systems. Cite this article: Bone Joint J 2021;103-B(6 Supple A):81–86


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 7 | Pages 889 - 892
1 Jul 2008
Al-Shawi A Badge R Bunker T

We have examined the accuracy of 143 consecutive ultrasound scans of patients who subsequently underwent shoulder arthroscopy for rotator-cuff disease. All the scans and subsequent surgery were performed by an orthopaedic surgeon using a portable ultrasound scanner in a one-stop clinic. There were 78 full thickness tears which we confirmed by surgery or MRI. Three moderate-size tears were assessed as partial-thickness at ultrasound scan (false negative) giving a sensitivity of 96.2%. One partially torn and two intact cuffs were over-diagnosed as small full-thickness tears by ultrasound scan (false positive) giving a specificity of 95.4%. This gave a positive predictive value of 96.2% and a negative predictive value of 95.4%. Estimation of tear size was more accurate for large and massive tears at 96.5% than for moderate (88.8%) and small tears (91.6%). These results are equivalent to those obtained by several studies undertaken by experienced radiologists. We conclude that ultrasound imaging of the shoulder performed by a sufficiently-trained orthopaedic surgeon is a reliable time-saving practice to identify rotator-cuff integrity


The Bone & Joint Journal
Vol. 100-B, Issue 10 | Pages 1399 - 1404
1 Oct 2018
Biedermann R Riccabona J Giesinger JM Brunner A Liebensteiner M Wansch J Dammerer D Nogler M

Aims. The purpose of this study was to analyze the incidence of the different ultrasound phenotypes of developmental dysplasia of the hip (DDH), and to determine their subsequent course. Patients and Methods. A consecutive series of 28 092 neonates was screened and classified according to the Graf method as part of a nationwide surveillance programme, and then followed prospectively. Abnormal hips were followed until they became normal (Graf type I). Type IIb hips and higher grades were treated by abduction in a Tübinger orthosis until normal. Dislocated hips underwent closed or open reduction. Results. Overall, 90.2% of hips were normal at birth. Type IIa hips (8.9%) became normal at a median of six weeks (interquartile range (IQR) 6 to 9). Type IIc and IId hips (0.67%) became normal after ten weeks (IQR 7 to 13). There were 19 type lll and eight type lV hips at baseline. There were 24 closed reductions and one open reduction. No late presentations of DDH were detected within the first five years of life. Conclusion. The incidence of DDH was eight per 1000 live births. The treatment rate was 1% (n = 273). The rate of first operations on the newborn hip was 0.86, and rate of open surgery was 0.04. The cumulative rate of open surgery was 0.07. The authors take the view that early identification and treatment in abduction of all dysplastic hips in early childhood reduces the rate of open reduction and secondary DDH-related surgery later in life. Cite this article: Bone Joint J 2018;100-B:1399–1404


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 10 | Pages 1433 - 1438
1 Oct 2012
Lam W Guo X Leung K Kwong KSC

This study was designed to test the hypothesis that the sensory innervation of bone might play an important role in sensing and responding to low-intensity pulsed ultrasound and explain its effect in promoting fracture healing. In 112 rats a standardised mid-shaft tibial fracture was created, supported with an intramedullary needle and divided into four groups of 28. These either had a sciatic neurectomy or a patellar tendon resection as control, and received the ultrasound or not as a sham treatment. Fracture union, callus mineralisation and remodelling were assessed using plain radiography, peripheral quantitative computed tomography and histomorphology. Daily ultrasound treatment significantly increased the rate of union and the volumetric bone mineral density in the fracture callus in the neurally intact rats (p = 0.025), but this stimulating effect was absent in the rats with sciatic neurectomy. Histomorphology demonstrated faster maturation of the callus in the group treated with ultrasound when compared with the control group. The results supported the hypothesis that intact innervation plays an important role in allowing low-intensity pulsed ultrasound to promote fracture healing


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 2 | Pages 258 - 263
1 Feb 2008
Parratte S Kilian P Pauly V Champsaur P Argenson JA

We have evaluated in vitro the accuracy of percutaneous and ultrasound registration as measured in terms of errors in rotation and version relative to the bony anterior pelvic plane in computer-assisted total hip replacement, and analysed the intra- and inter-observer reliability of manual or ultrasound registration. Four clinicians were asked to perform registration of the landmarks of the anterior pelvic plane on two cadavers. Registration was performed under four different conditions of acquisition. Errors in rotation were not significant. Version errors were significant with percutaneous methods (16.2°; p < 0.001 and 19.25° with surgical draping; p < 0.001), but not with the ultrasound acquisition (6.2°, p = 0.13). Intra-observer repeatability was achieved for all the methods. Inter-observer analysis showed acceptable agreement in the sagittal but not in the frontal plane. Ultrasound acquisition of the anterior pelvic plane was more reliable in vitro than the cutaneous digitisation currently used


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 9 | Pages 1264 - 1266
1 Sep 2005
Paton RW Hinduja K Thomas CD

Of the 34 723 infants born between 1 June 1992 and 31 May 2002, the hips of 2578 with clinical instability or at-risk factors for developmental dysplasia of the hip were imaged by ultrasound. Instability of the hip was present in 77 patients, of whom only 24 (31.2%) had an associated risk factor. From the ‘at-risk’ groups, the overall risk of type-III dysplasia, instability and irreducibility was 1:15 when family history, 1:27 when breech delivery and 1:33 when foot deformity were considered as risk factors. Of those hips which were ultrasonographically stable, 88 had type-III dysplasia. A national programme of selective ultrasound screening of at-risk factors for the diagnosis of hip dislocation or instability alone cannot be recommended because of its low predictive value (1:88). However, the incidence of type-III dysplasia and hip dislocation or dislocatability in the groups with clinical instability, family history, breech position and possibly postural foot deformity as risk factors could justify a programme of selective ultrasound imaging


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 11 | Pages 1405 - 1409
1 Nov 2009
Mitchell AWM Lee JC Healy JC

The use of ultrasound in the diagnosis and management of disorders of the tendo Achillis is discussed. Some of the pathological processes which occur in Achilles tendinopathy can be identified by ultrasound, which may also be used to direct local treatment


The Journal of Bone & Joint Surgery British Volume
Vol. 71-B, Issue 5 | Pages 767 - 773
1 Nov 1989
Terjesen T Bredland T Berg V

The hips of 1000 newborn babies were examined clinically and by ultrasonography. The ultrasound assessment was based on measurements of the coverage of the femoral head by the bony acetabular roof, and this parameter was called the Bony Rim Percentage (BRP). The mean BRP was 55.3% in girls and 57.2% in boys, a significant difference. Clinical instability occurred in 0.7% of the newborn babies, and all of the unstable hips had a BRP below the lower limit of normal. All infants with normal clinical findings and suspected abnormal hips based on ultrasound were followed up; in all but two the hips became normal spontaneously. We conclude that ultrasonography, using the measurements of femoral head coverage, is appropriate for screening the newborn, is reliable in differentiating between a true and a false positive Ortolani sign, and that hip dysplasia which is not clinically demonstrable at birth can be detected by ultrasound. Ultrasound should replace radiography as the routine method of following up high-risk infants and those with suspicious signs


The Journal of Bone & Joint Surgery British Volume
Vol. 84-B, Issue 6 | Pages 886 - 890
1 Aug 2002
Holen KJ Tegnander A Bredland T Johansen OJ Sæther OD Eik-Nes SH Terjesen T

The aim of this study was to evaluate whether universal (all neonates) or selective (neonates belonging to the risk groups) ultrasound screening of the hips should be recommended at birth. We carried out a prospective, randomised trial between 1988 and 1992, including all newborn infants at our hospital. A total of 15 529 infants was randomised to either clinical screening and ultrasound examination of all hips or clinical screening of all hips and ultrasound examination only of those at risk. The effect of the screening was assessed by the rate of late detection of congenital or developmental hip dysplasia in the two groups. During follow-up of between six and 11 years, only one late-detected hip dysplasia was seen in the universal group, compared with five in the subjective group, representing a rate of 0.13 and 0.65 per 1000, respectively. The difference in late detection between the two groups was not statistically significant (p = 0.22). When clinical screening is of high quality, as in our study, the effect of an additional ultrasound examination, measured as late-presenting hip dysplasia, is marginal. Under such circumstances, we consider that universal ultrasound screening is not necessary, but recommend selective ultrasound screening for neonates with abnormal or suspicious clinical findings and those with risk factors for hip dysplasia


The Journal of Bone & Joint Surgery British Volume
Vol. 65-B, Issue 2 | Pages 144 - 147
1 Mar 1983
Howie D Chatterton B Hone M

This paper reports a prospective study of the value of ultrasonography in detecting lesions of the lumbar spine in patients with compressive sciatica. The measurements of the diameter of the spinal canal obtained by using ultrasound were compared with the findings at operation in 17 patients in whom a total of 50 sites were examined. The ultrasound beam failed to penetrate the spinal canal at 15 sites and at only 10 of the remaining 35 sites did the ultrasound correctly detect narrowing. It is concluded that ultrasonography is unreliable in identifying the site of compression of the spinal cord and nerve roots. The technical limitations and the probable causes of failure of the technique are discussed


The Journal of Bone & Joint Surgery British Volume
Vol. 82-B, Issue 8 | Pages 1170 - 1173
1 Nov 2000
Hübner U Schlicht W Outzen S Barthel M Halsband H

We compared the results of primary ultrasonographic examination of 163 children with 224 suspected fractures with the subsequent radiological findings. The aim was to assess the value of ultrasound in the diagnosis of fractures in children. We found a good correlation for fractures of the long bones of the upper and lower limbs. Ultrasound was most reliable for the detection of simple femoral and humeral diaphyseal fractures and fractures of the forearm. It was less dependable for compound injuries and fractures adjacent to joints, lesions of the small bones of the hand and foot, non-displaced epiphyseal fractures (Salter-Harris type 1) or those with a fracture line of less than 1mm. We were able to distinguish several types of fracture in which the use of ultrasound alone gave reliable information and further radiography was unnecessary. We discuss the advantages and disadvantages of skeletal ultrasonographic studies in children


The Bone & Joint Journal
Vol. 96-B, Issue 7 | Pages 984 - 988
1 Jul 2014
Pullinger M Southorn T Easton V Hutchinson R Smith RP Sanghrajka AP

Congenital Talipes Equinovarus (CTEV) is one of the most common congenital limb deformities. We reviewed the records of infants who had received treatment for structural CTEV between 1 January 2007 and 30 November 2012. This was cross-referenced with the prenatal scans of mothers over a corresponding period of time. We investigated the sensitivity, specificity, and positive and negative predictive values of the fetal anomaly scan for the detection of CTEV and explored whether the publication of Fetal Anomaly Screening Programme guidelines in 2010 affected the rate of detection. During the study period there were 95 532 prenatal scans and 34 373 live births at our hospital. A total of 37 fetuses with findings suggestive of CTEV were included in the study, of whom 30 were found to have structural CTEV at birth. The sensitivity of screening for CTEV was 71.4% and the positive predictive value was 81.1%. The negative predictive value and specificity were more than 99.5%. There was no significant difference between the rates of detection before and after publication of the guidelines (p = 0.5). We conclude that a prenatal fetal anomaly ultrasound screening diagnosis of CTEV has a good positive predictive value enabling prenatal counselling. The change in screening guidance has not affected the proportion of missed cases. This information will aid counselling parents about the effectiveness and accuracy of prenatal ultrasound in diagnosing CTEV. Cite this article: Bone Joint J 2014;96-B:984–8


Bone & Joint Research
Vol. 5, Issue 11 | Pages 538 - 543
1 Nov 2016
Weeks BK Hirsch R Nogueira RC Beck BR

Objectives. The aim of the current study was to assess whether calcaneal broadband ultrasound attenuation (BUA) can predict whole body and regional dual-energy x-ray absorptiometry (DXA)-derived bone mass in healthy, Australian children and adolescents at different stages of maturity. Methods. A total of 389 boys and girls across a wide age range (four to 18 years) volunteered to participate. The estimated age of peak height velocity (APHV) was used to classify children into pre-, peri-, and post-APHV groups. BUA was measured at the non-dominant heel with quantitative ultrasonometry (QUS) (Lunar Achilles Insight, GE), while bone mineral density (BMD) and bone mineral content (BMC) were examined at the femoral neck, lumbar spine and whole body (DXA, XR-800, Norland). Associations between BUA and DXA-derived measures were examined with Pearson correlations and linear regression. Participants were additionally ranked in quartiles for QUS and DXA measures in order to determine agreement in rankings. Results. For the whole sample, BUA predicted 29% of the study population variance in whole body BMC and BMD, 23% to 24% of the study population variance in lumbar spine BMC and BMD, and 21% to 24% of the variance in femoral neck BMC and BMD (p < 0.001). BUA predictions were strongest for the most mature participants (pre-APHV R. 2. = 0.03 to 0.19; peri-APHV R. 2. = 0.05 to 0.17; post-APHV R. 2. = 0.18 to 0.28) and marginally stronger for girls (R. 2. = 0.25-0.32, p < 0.001) than for boys (R. 2. = 0.21-0.27, p < 0.001). Agreement in quartile rankings between QUS and DXA measures of bone mass was generally poor (27.3% to 38.2%). Conclusion. Calcaneal BUA has a weak to moderate relationship with DXA measurements of bone mass in children, and has a tendency to misclassify children on the basis of quartile rankings. Cite this article: B. K. Weeks, R. Hirsch, R. C. Nogueira, B. R. Beck. Is calcaneal broadband ultrasound attenuation a valid index of dual-energy x-ray absorptiometry-derived bone mass in children? Bone Joint Res 2016;5:538–543. DOI: 10.1302/2046-3758.511.BJR-2016-0116.R1


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 8 | Pages 1126 - 1130
1 Aug 2011
Thaler M Biedermann R Lair J Krismer M Landauer F

Between 1978 and 1997 all newborns in the Austrian province of Tyrol were reviewed regarding hip dysplasia and related surgery. This involved a mean of 8257 births per year (7766 to 8858). Two observation periods were determined: 1978 to 1982 (clinical examination alone) and 1993 to 1997 (clinical examination and universal ultrasound screening). A retrospective analysis compared the number and cost of interventions due to hip dysplasia in three patient age groups: A, 0 to < 1.5 years; B, ≥ 1.5 to < 15 years; and C, ≥ 15 to < 35 years. In group A, there was a decrease in hip reductions from a mean of 25.2 (. sd. 2.8) to 7.0 (. sd. 1.4) cases per year. In group B, operative procedures decreased from a mean of 17.8 (. sd. 3.5) to 2.6 (. sd. 1.3) per year. There was a 75.9% decrease in the total number of interventions for groups A and B. An increase of €57 000 in the overall cost per year for the second period (1993 to 1997) was seen, mainly due to the screening programme. However, there was a marked reduction in costs of all surgical and non-surgical treatments for dysplastic hips from €410 000 (1978 to 1982) to €117 000 (1993 to 1997). We believe the small proportional increase in costs of the universal ultrasound screening programme is justifiable as it was associated with a reduction in the number of non-surgical and surgical interventions. We therefore recommend universal hip ultrasound screening for neonates


The Journal of Bone & Joint Surgery British Volume
Vol. 82-B, Issue 7 | Pages 1077 - 1082
1 Sep 2000
Shimazaki A Inui K Azuma Y Nishimura N Yamano Y

We investigated the effects of low-intensity pulsed ultrasound on distraction osteogenesis in a rabbit model. Callotasis of the right tibia was performed in 70 male Japanese white rabbits using mini-external fixators. In the first part of the study in 64 animals using normal distraction (waiting period seven days; distraction rate 0.5 mm/12 hours; distraction period ten days), we evaluated the distraction site by radiography, measurement of the bone mineral density (BMD), mechanical testing, and histology. In the second part in six rabbits using fast distraction (waiting period 0 days; distraction rate 1.5 mm/12 hours; distraction period seven days) the site was evaluated radiologically. Half of the animals (35) had received ultrasound to their right leg (30mW/cm. 2. ) for 20 minutes daily after ceasing distraction (ultrasound group), while rigid fixation only was maintained in the other half (control group). With normal distraction, the hard callus area, as shown by radiography, the BMD, and the findings on mechanical testing, were significantly greater in those receiving ultrasound than in the control group. Histological analysis showed no tissue damage attributable to exposure to ultrasound. With fast distraction, immature bone regeneration was observed radiologically in the control group, while bone maturation was achieved in the ultrasound group. We conclude that ultrasound can accelerate bone maturation in distraction osteogenesis in rabbits, even in states of poor callotasis


The Journal of Bone & Joint Surgery British Volume
Vol. 78-B, Issue 4 | Pages 636 - 640
1 Jul 1996
Terjesen T Holen KJ Tegnander A

We have followed the natural progress of newborn infants in whom ultrasound examination showed abnormalities in hips which appeared to be clinically normal. Over six years we saw 306 such children out of 9952 examined (31 per 1000 live births). The examination was repeated at two to three months and those who still showed an abnormality were followed up further. At four to five months a standard radiograph was obtained, and treatment began if this and another ultrasound scan were both abnormal. At this stage, 291 infants had normal hips. In the 15 infants with abnormal hips there was no pronounced deterioration, none developed a frank dislocation, and all became normal after treatment in an abduction splint. Newborn infants with abnormal and suspicious ultrasound findings who are normal on clinical examination do not need treatment from birth; most of these hips will settle spontaneously. Treatment can be postponed until the age of four to five months unless clinical instability develops or ultrasound shows dislocation. The criteria for treatment should be based on measurements by both ultrasound and radiography: both should show an abnormality before intervention is considered necessary


The Journal of Bone & Joint Surgery British Volume
Vol. 81-B, Issue 5 | Pages 846 - 851
1 Sep 1999
Holen KJ Tegnander A Eik-Nes SH Terjesen T

We have evaluated the effect of the use of ultrasound in determining the initiation of treatment in neonatal instability of the hip. A total of 99 newborn infants (1.5% of all live births) with neonatal hip instability did not have treatment from birth, but were re-examined at eight to 15 days. In the 31 who had persisting clinical instability and ultrasound abnormality, treatment was then started with a Frejka pillow. The hips in the remaining 68 infants showed spontaneous clinical stabilisation and improvement of the ultrasound findings. Treatment was therefore withheld. There was a marked trend towards normal development in mildly unstable hips, whereas no hips with severe instability did so spontaneously. Further follow-up showed normal development in all the hips which had been treated, and in all except five of the 68 untreated infants. These five infants showed persistent hip dysplasia on both ultrasound and radiological examination at four to five months of age. Treatment with an abduction splint was then started and their hips developed normally. Ultrasound is very useful in deciding on treatment if the examiners have adequate experience with the method. Its use substantially reduces the rate of treatment. Spontaneous resolution occurred in more than half of the unstable hips. Since five of the untreated infants developed hip dysplasia a strict follow-up is essential to identify and treat these cases


The Journal of Bone & Joint Surgery British Volume
Vol. 67-B, Issue 3 | Pages 406 - 412
1 May 1985
Clarke N Harcke H McHugh P Lee M Borns P MacEwen G

A technique of examining the infant hip joint with real-time ultrasound is described. Since the cartilaginous femoral head is clearly imaged by ultrasound, anatomical structures and their relationships can be accurately determined. Dislocated hips are easily detected and subluxations also can be visualized. We report our experience with 131 examinations in 104 patients, comprising 259 single hip studies. Of 83 patients who were previously untreated, there were 178 hip studies with three false-negative and four false-positive ultrasound results. No dislocations were missed. Twenty-seven patients who were already being treated were examined to assess hip location, comprising a total of 81 hip studies. In some cases the patients were examined while in an abduction device, cast, or Pavlik harness. In one case a dislocation was not detected. The method of examination using real-time ultrasound is considered to be reliable, accurate, and a useful adjunct to radiography. The advantages are that it is non-invasive, portable, and involves no exposure to radiation


The Journal of Bone & Joint Surgery British Volume
Vol. 82-B, Issue 6 | Pages 876 - 880
1 Aug 2000
Tillett RL Fisk NM Murphy K Hunt DM

Congenital talipes equinovarus is a common anomaly which can now be diagnosed prenatally on a routine ultrasound scan at 20 weeks of gestation. Prenatal counselling is increasingly offered to parents with affected fetuses, but it is difficult to counsel parents if there is a chance that the fetus may not have talipes. Our study correlates the prenatal ultrasound findings of 14 infants diagnosed as having unilateral or bilateral talipes during their routine 20-week ultrasound scan with their clinical findings at birth and the treatment received. No feet diagnosed as talipes on the ultrasound scan were completely normal at birth and therefore there were no true false-positive results. One foot graded as normal at 20 weeks was found to have a mild grade-1 talipes at birth, but did not require treatment other than simple stretches. A total of 32% of feet required no treatment and so could be considered functional false-positive results on the scan. Serial casting was required by 13% of feet and surgical treatment by 55%. The severity of the talipes is difficult to establish before birth. A number of patients are likely to need surgical treatment, but a proportion will have talipes so mildly that no treatment will be required. In counselling parents at 20 weeks, orthopaedic surgeons need to know whether or not there is a small chance that the ultrasound diagnosis could be wrong and also that the talipes may be so mild that the foot will not require treatment


Bone & Joint Research
Vol. 5, Issue 2 | Pages 26 - 32
1 Feb 2016
Wendling A Mar D Wischmeier N Anderson D McIff T

Objectives. The objective of this study was to determine if combining variations in mixing technique of antibiotic-impregnated polymethylmethacrylate (PMMA) cement with low frequency ultrasound (LFUS) improves antibiotic elution during the initial high phase (Phase I) and subsequent low phase (Phase II) while not diminishing mechanical strength. Methods. Three batches of vancomycin-loaded PMMA were prepared with different mixing techniques: a standard technique; a delayed technique; and a control without antibiotic. Daily elution samples were analysed using flow injection analysis (FIA). Beginning in Phase II, samples from each mix group were selected randomly to undergo either five, 15, 45, or 0 minutes of LFUS treatment. Elution amounts between LFUS treatments were analysed. Following Phase II, compression testing was done to quantify strength. A-priorit-tests and univariate ANOVAs were used to compare elution and mechanical test results between the two mix groups and the control group. Results. The delayed technique showed a significant increase in elution on day one compared with the standard mix technique (p < 0.001). The transition point from Phase I to Phase II occurred on day ten. LFUS treatments significantly increased elution amounts for all groups above control. Delayed technique resulted in significantly higher elution amounts for the five-minute- (p = 0.004) and 45-minute- (p < 0.001) duration groups compared with standard technique. Additionally, the correlations between LFUS duration and total elution amount for both mix techniques were significant (p = 0.03). Both antibiotic-impregnated groups exhibited a significant decrease in offset yield stress compared with the control group (p < 0.001), however, their lower 95% confidence intervals were all above the 70 MPa limit defined by International Standards Organization (ISO) 5833-2 reference standard for acrylic bone cement. Conclusion. The combination of a delayed mix technique with LFUS treatments provides a reasonable means for increasing both short- and long-term antibiotic elution without affecting mechanical strength. Cite this article: Dr. T. McIff. Combination of modified mixing technique and low frequency ultrasound to control the elution profile of vancomycin-loaded acrylic bone cement. Bone Joint Res 2016;5:26–32. doi: 10.1302/2046-3758.52.2000412


The Journal of Bone & Joint Surgery British Volume
Vol. 71-B, Issue 2 | Pages 237 - 239
1 Mar 1989
Lausten G Jorgensen F Boesen J

Anteversion of the femoral neck of 30 unpaired dry bones was measured directly, by ultrasound, and by computerised tomography. The angles measured directly corresponded well with the angles found by CT scan, but there was poor correlation between these and the angles measured by ultrasound. At present ultrasound seems to be unsuitable for the measurement of anteversion of the femoral neck


The Journal of Bone & Joint Surgery British Volume
Vol. 75-B, Issue 1 | Pages 79 - 82
1 Jan 1993
Howard C Einhorn M Dagan R Nyska M

We reviewed the ultrasound findings in 59 children suspected of having bone infection. Twenty-nine were eventually proved to have acute haematogenous osteomyelitis and 26 of these showed characteristic ultrasound findings. Such changes were rare in 30 patients with other clinically similar conditions. Ultrasound examination was also able to detect the presence of subperiosteal pus and thus indicate the need for surgical treatment


The Journal of Bone & Joint Surgery British Volume
Vol. 72-B, Issue 2 | Pages 197 - 201
1 Mar 1990
Engesaeter L Wilson D Nag D Benson M

One-hundred newborn children at high risk of hip instability were prospectively assessed clinically and by ultrasound. The decision to treat was based only on the clinical examination. At the age of three months all the children were evaluated clinically and with an anteroposterior radiograph of the pelvis. None of the standard ultrasound measurements of acetabular depth and femoral head cover correlated with the outcome at three months. Dynamic assessment of stability was the only ultrasound technique that had a significant relation with outcome


The Journal of Bone & Joint Surgery British Volume
Vol. 71-B, Issue 1 | Pages 9 - 12
1 Jan 1989
Clarke N Clegg J Al-Chalabi A

Of 4,617 babies born in Coventry in 1986, a total of 448 (9.7%) had either clinical abnormality of the hip or at risk factors for CDH. All were examined by ultrasound, but only 17 required treatment (3.7 per 1,000); in five of these no clinical abnormality had been detected. An additional 81 babies had ultrasound abnormalities but did not require treatment, despite the fact that ultrasound at first showed major hip displacement in 17 of them. Three late cases of CDH have presented among the babies born in 1986, but not examined by ultrasound. This incidence of late CDH is unchanged compared with the previous nine years, although ultrasound had detected covert displacement in a number of hips


The Journal of Bone & Joint Surgery British Volume
Vol. 76-B, Issue 4 | Pages 534 - 538
1 Jul 1994
Marks D Clegg J al-Chalabi A

We have undertaken routine ultrasound screening for neonatal hip instability in Coventry since June 1989. Of the 14,050 babies scanned during the first three years, 847 (6%) had ultrasound abnormalities. A grading system, based on the percentage of femoral head coverage, is presented. The proportion of abnormal hips decreased gradually so that by nine weeks, 90% had normal ultrasound appearances. Abnormality was more common in babies with a family history of CDH and in breech presentations. All babies with clinically abnormal hips had an abnormal first ultrasound examination. Five babies not diagnosed by clinical examination and with no risk factors had abnormal ultrasound appearances and were subsequently found to have clinically abnormal hips. Routine ultrasound screening has detected cases which would otherwise have presented late


The Journal of Bone & Joint Surgery British Volume
Vol. 72-B, Issue 4 | Pages 549 - 553
1 Jul 1990
Bickerstaff D Neal L Booth A Brennan P Bell M

We made a prospective study of 111 children with acute hip pain to assess whether ultrasound can replace traditional radiography. An effusion was diagnosed in 71% by ultrasound but in only 15% by radiography. This effusion persisted for a mean of nine days; symptoms lasted for five days. Two patients found to have Perthes' disease had longer-lasting effusion and symptoms. Patients without an effusion had no obvious cause for their pain, so the pressure of an effusion from a transient synovitis does not account for all patients with irritable hips. Patients with an effusion persisting for over 24 days (the mean + 2 s.d. of our series) had more symptoms, a significantly larger effusion and greater limitation of movement. They may be more at risk for avascular necrosis. We found that radiographic examination influenced the immediate management of only two patients, those with Perthes' disease. We therefore propose a protocol of management for irritable hip, using ultrasonography at the first presentation of certain categories of patients. This would reduce the number of early radiographs by 75%


The Bone & Joint Journal
Vol. 99-B, Issue 6 | Pages 806 - 811
1 Jun 2017
Takahashi N Sugaya H Matsuki K Miyauchi H Matsumoto M Tokai M Onishi K Hoshika S Ueda Y

Aims. The aim of this study was to assess hypertrophy of the extra-articular tendon of the long head of biceps (LHB) in patients with a rotator cuff tear. Patients and Methods. The study involved 638 shoulders in 334 patients (175 men, 159 women, mean age 62.6 years; 25 to 81) with unilateral symptomatic rotator cuff tears. The cross-sectional area (CSA) of the LHB tendon in the bicipital groove was measured pre-operatively in both shoulders using ultrasound. There were 154 asymptomatic rotator cuff tears in the contralateral shoulder. Comparisons were made between those with a symptomatic tear, an asymptomatic tear and those with no rotator cuff tear. In the affected shoulders, the CSAs were compared in relation to the location and size of the rotator cuff tear. . Results. The mean CSA was 21.0 mm. 2 . (4 to 71) in those with a symptomatic rotator cuff tear, 19.9 mm. 2. (4 to 75) in those with an asymptomatic rotator cuff tear and 14.1 mm. 2 . (5 to 43) in those with no rotator cuff tear. The mean CSA in patients with both symptomatic and asymptomatic rotator cuff tears was significantly larger than in those with no rotator cuff tear (p < 0.001). In the affected shoulders, there were significant differences between patients with more than a medium sized posterosuperior cuff tear and those with an antero-superior cuff tear. . Conclusion . Regardless of the symptoms, there was significant hypertrophy of the extra-articular LHB tendon in patients with a rotator cuff tear. The values were significantly related to the size of the tear. Cite this article: Bone Joint J 2017;99-B:806–11


The Journal of Bone & Joint Surgery British Volume
Vol. 71-B, Issue 2 | Pages 252 - 255
1 Mar 1989
Suzuki S Yamamuro T Shikata J Shimizu K Iida H

Ultrasound can be used to outline the spinous processes and the laminae, and thus to measure axial rotation. Using our own technique, we measured vertebral rotation in 47 patients with idiopathic scoliosis. There was a strong linear relationship between the Cobb angle and the rotation of the apical vertebra in untreated patients, but this relationship was lost in patients who had had brace treatment. Vertebral rotation can easily be measured by ultrasound. This is a harmless and fairly rapid investigation which can be used at routine follow-up examination of patients with idiopathic scoliosis


The Journal of Bone & Joint Surgery British Volume
Vol. 85-B, Issue 1 | Pages 117 - 120
1 Jan 2003
van Douveren FQMP Pruijs HEH Sakkers RJB Nievelstein RAJ Beek FJA

In this prospective study of 18 hips we compared the efficacy of ultrasound with CT in determining the position of the femoral head in a spica cast after closed or open reduction in children with developmental dysplasia of the hip. Ultrasound was performed through the perineal opening of the cast. With a transinguinal approach, the superior ramus of the pubis, the acetabulum, the femoral head and the femoral neck can be depicted in one plane. The CT and ultrasound images were blinded and reviewed by two of the authors. Ultrasound was inconclusive in the first two reductions since the perineal opening was too small to see all the landmarks in one plane. In the following 16 reductions the landmarks were well defined and interpretation of the CT and ultrasound was similar. The perineal opening in the spica cast should be made in such a way that the ultrasound probe can be positioned in the groin so that the landmarks can be shown in one plane


The Journal of Bone & Joint Surgery British Volume
Vol. 85-B, Issue 7 | Pages 999 - 1005
1 Sep 2003
Sharp RJ Wade CM Hennessy MS Saxby TS

We investigated 29 cases, diagnosed clinically as having Morton’s neuroma, who had undergone MRI and ultrasound before a neurectomy. The accuracy with which pre-operative clinical assessment, ultrasound and MRI had correctly diagnosed the presence of a neuroma were compared with one another based on the histology and the clinical outcome. Clinical assessment was the most sensitive and specific modality. The accuracy of the ultrasound and MRI was similar and dependent on size. Ultrasound was especially inaccurate for small lesions. There was no correlation between the size of the lesion and either the pre-operative pain score or the change in pain score following surgery. Reliance on single modality imaging would have led to inaccurate diagnosis in 18 cases and would have only benefited one patient. Even imaging with both modalities failed to meet the predictive values attained by clinical assessment. There is no requirement for ultrasound or MRI in patients who are thought to have a Morton’s neuroma. Small lesions, < 6 mm in size, are equally able to cause symptoms as larger lesions. Neurectomy provides an excellent clinical outcome in most cases


The Journal of Bone & Joint Surgery British Volume
Vol. 69-B, Issue 2 | Pages 268 - 270
1 Mar 1987
Berman L Mitchell R Katz D

The calculation of femoral anteversion using a static ultrasound scanner has been compared with results obtained by computer tomographic (CT) scanning. Assuming the CT results to be accurate, the ultrasound method was frequently found to be unreliable


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 10 | Pages 1449 - 1451
1 Oct 2010
Jaiswal A Starks I Kiely NT

We present a case of late dislocation of the hip in a 30-month-old girl. Her hip was clinically stable at birth and an ultrasound scan at six weeks was normal. She had no additional risk factors for developmental dysplasia. She underwent anterior open reduction with a femoral osteotomy


The Journal of Bone & Joint Surgery British Volume
Vol. 75-B, Issue 1 | Pages 66 - 68
1 Jan 1993
Mahaisavariya B Laupattarakasem W

We describe a method of closed, unlocked nailing for femoral fractures using ultrasound instead of an image intensifier. Radiography was used only to confirm that the guide wire had been passed into the intramedullary canal of both fragments. The method succeeded in 26 of 30 cases. The failures all occurred in fractures which could not be reduced within 20 minutes. The operating time in those nailed successfully with ultrasound control was not different from the time for 30 control cases using conventional methods with an image intensifier


The Journal of Bone & Joint Surgery British Volume
Vol. 81-B, Issue 4 | Pages 675 - 678
1 Jul 1999
Wallny T Wagner UA Prange S Schmitt O Reich H

The diagnosis of chronic lesions of the rotator cuff is challenging. We have developed a new index to improve the sonographic diagnosis of chronic tears of the cuff. In a pilot study, we examined 50 asymptomatic healthy volunteers by ultrasound to establish the diameter of the rotator cuff in relation to the tendon of the long head of biceps. Subsequently, the index was calculated in 64 patients who had had shoulder pain for more than three months caused by clinically diagnosed lesions of the rotator cuff. The compensatory hypertrophy of the biceps tendon was quantified sonographically in relation to the diameter of the cuff. Comparison with the contralateral shoulder revealed a significantly higher biceps rotator-cuff ratio (p < 0.05) for patients with torn rotator cuffs. A ratio greater than 0.8 was considered pathological (index positive); the mean ratio in the control group was 0.43. The sensitivity of a positive index was 97.8%, the specificity 63.2%, the positive predictive value 86.3%, and the negative predictive value 92.4% in comparison with surgical findings. Use of the index improves sensitivity in the diagnosis of chronic tears of the cuff by ultrasound


The Journal of Bone & Joint Surgery British Volume
Vol. 81-B, Issue 2 | Pages 255 - 258
1 Mar 1999
Paton RW Srinivasan MS Shah B Hollis S

Between May 1992 and April 1997, there were 20 452 births in the Blackburn District. In the same period 1107 infants with hip ‘at-risk’ factors were screened prospectively by ultrasound. We recorded the presence of dislocation and dysplasia detected under the age of six months using Graf’s alpha angle. Early dislocation was present in 36 hips (34 dislocatable and 2 irreducible). Of the 36 unstable hips, 30 (83%) were referred as being Ortolani-positive or unstable; 25 (69%) of these had at least one of the risk factors. Only 11 (31%) were identified from the ‘at-risk’ screening programme alone (0.54 per 1000 live births). Eight cases of ‘late’ dislocation presented after the age of six months (0.39 per 1000 live births). The overall rate of dislocation was 2.2 per 1000 live births. Only 31% of the dislocated hips belonged to a major ‘at-risk’ group. Statistical analysis confirmed that the risk factors had a relatively poor predictive value if used as a screening test for dislocation. In infants referred for doubtful clinical instability, one dislocation was detected for every 11 infants screened (95% confidence interval (CI) 8 to 17) whereas in infants referred because of the presence of any of the major ‘at-risk’ factors the rate was one in 75 (95% CI 42 to 149). Routine ultrasound screening of the ‘at-risk’ groups on their own is of little value in significantly reducing the rate of ‘late’ dislocation in DDH, but screening clinically unstable hips alone or associated with ‘at-risk’ factors has a high rate of detection


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 4 | Pages 525 - 530
1 Apr 2011
Tobita K Ohnishi I Matsumoto T Ohashi S Bessho M Kaneko M Matsuyama J Nakamura K

We evaluated the effect of low-intensity pulsed ultrasound stimulation (LIPUS) on the remodelling of callus in a rabbit gap-healing model by bone morphometric analyses using three-dimensional quantitative micro-CT. A tibial osteotomy with a 2 mm gap was immobilised by rigid external fixation and LIPUS was applied using active translucent devices. A control group had sham inactive transducers applied. A region of interest of micro-CT was set at the centre of the osteotomy gap with a width of 1 mm. The morphometric parameters used for evaluation were the volume of mineralised callus (BV) and the volumetric bone mineral density of mineralised tissue (mBMD). The whole region of interest was measured and subdivided into three zones as follows: the periosteal callus zone (external), the medullary callus zone (endosteal) and the cortical gap zone (intercortical). The BV and mBMD were measured for each zone. In the endosteal area, there was a significant increase in the density of newly formed callus which was subsequently diminished by bone resorption that overwhelmed bone formation in this area as the intramedullary canal was restored. In the intercortical area, LIPUS was considered to enhance bone formation throughout the period of observation. These findings indicate that LIPUS could shorten the time required for remodelling and enhance the mineralisation of callus


The Journal of Bone & Joint Surgery British Volume
Vol. 76-B, Issue 4 | Pages 525 - 533
1 Jul 1994
Boeree N Clarke N

We report the preliminary results of a continuing prospective evaluation of a screening programme for congenital dislocation of the hip (CDH) which uses ultrasound imaging to provide delayed selective screening to complement neonatal clinical screening. Of 26,952 births in the Southampton district, 1894 infants were referred for secondary screening because of a clinical abnormality or the presence of a predetermined risk category for CDH. Pavlik harness treatment was required for only 118 infants, giving a treatment rate of 4.4 per 1000 births. Of those referred with clinical instability, 35% did not require treatment. Dislocation or subluxation was detected in 17 of 643 infants referred only because they fell within one of three risk categories: breech presentation, foot deformity and family history. All 17 had normal clinical examinations and cases were discovered in each category. Six children presented with CDH after 12 weeks of age, giving a late presentation rate of 0.22 per 1000 births. All had normal clinical examinations within 24 hours of birth and none was in a risk category. Surgery has been required in ten children, giving a surgical treatment rate of 0.37 per 1000 births. We conclude that, in Southampton, delayed selective secondary screening with ultrasound is more effective than clinical screening alone. It targets treatment to those infants who need it, and reveals a number of dislocated and subluxed hips that would otherwise be missed


The Bone & Joint Journal
Vol. 95-B, Issue 1 | Pages 132 - 134
1 Jan 2013
Barr LV Rehm A

Twins are often considered to be at an increased risk of developmental dysplasia of the hip (DDH); we therefore investigated whether multiple births have a higher incidence of DDH, and if selective ultrasound scanning should be considered for these infants. We reviewed our records of all live births between 1 January 2004 and 31 December 2008 and included 25 246 single and 990 multiple births. Multiple births did not have a significantly higher incidence of DDH compared with single births (0.0030 vs 0.0023, p = 0.8939). Of the 990 multiple births, 267 had neonatal ultrasound scans and one case of DDH was diagnosed and treated successfully with a Pavlik harness. There were two late-presenting cases at eight and 14 months of age, neither of whom had risk factors for DDH and consequently had not had a neonatal scan. Whereas selective ultrasound scanning of multiple births would have led to earlier detection and treatment of the late-presenting cases, they did not have a significantly higher incidence of DDH compared with single births. We conclude that being a twin or triplet in itself is not a risk factor for DDH and that selective ultrasound scanning is not indicated for this population. Cite this article: Bone Joint J 2013;95-B:132–4


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 1 | Pages 51 - 55
1 Jan 2010
Omonbude D El Masry MA O’Connor PJ Grainger AJ Allgar VL Calder SJ

We prospectively randomised 78 patients into two groups, ‘drains’ or ‘no drains’ to assess the effectiveness of suction drains in reducing haematoma and effusion in the joint and its effect on wound healing after total knee replacement. Ultrasound was used to measure the formation of haematoma and effusion on the fourth post-operative day. This was a semi-quantitative assessment of volume estimation. There was no difference in the mean effusion between the groups (5.91 mm in the drain group versus 6.08 mm in the no-drain, p = 0.82). The mean amount of haematoma in the no-drain group was greater (11.07 mm versus 8.41 mm, p = 0.03). However, this was not clinically significant judged by the lack of difference in the mean reduction in the post-operative haemoglobin between the groups (drain group 3.4 g/dl; no-drain group 3.0 g/dl, p = 0.38). There were no cases of wound infection or problems with wound healing at six weeks in any patient. Our findings indicate that drains do not reduce joint effusion but do reduce haematoma formation. They have no effect on wound healing


The Journal of Bone & Joint Surgery British Volume
Vol. 75-B, Issue 3 | Pages 483 - 487
1 May 1993
Suzuki S

Sixty-nine hips in 62 patients were treated by the Pavlik harness for congenital dislocation. Ultrasonography showed three degrees of residual head displacement when the harness was first applied. In type A, the femoral head showed contact with the inner posterior wall of the acetabulum. In type B, it contacted the posterior margin of the socket, with its centre at or anterior to the acetabular rim. In type C, the femoral head was displaced outside the socket, with its centre posterior to the acetabular rim. All 51 hips with type A displacement remained reduced. Of nine hips of type B, five were reduced, but the other four were not. None of the nine hips with type C dislocation became reduced with continued use of the harness. The Pavlik harness is indicated for type A and some type B dislocations, but the latter need daily ultrasound monitoring, with a change in method of treatment if type C displacement appears or if the hip is not reduced within one or two weeks. Treatment by Pavlik harness is not indicated in hips with type C dislocations


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 2 | Pages 264 - 270
1 Feb 2009
Hasegawa T Miwa M Sakai Y Niikura T Kurosaka M Komori T

The haematoma occurring at the site of a fracture is known to play an important role in bone healing. We have recently shown the presence of progenitor cells in human fracture haematoma and demonstrated that they have the capacity for multilineage mesenchymal differentiation. There have been many studies which have shown that low-intensity pulsed ultrasound (LIPUS) stimulates the differentiation of a variety of cells, but none has investigated the effects of LIPUS on cells derived from human fracture tissue including human fracture haematoma-derived progenitor cells (HCs). In this in vitro study, we investigated the effects of LIPUS on the osteogenic activity of HCs. Alkaline phosphatase activity, osteocalcin secretion, the expression of osteoblast-related genes and the mineralisation of HCs were shown to be significantly higher when LIPUS had been applied but without a change in the proliferation of the HCs. These findings provide evidence in favour of the use of LIPUS in the treatment of fractures


The Journal of Bone & Joint Surgery British Volume
Vol. 64-B, Issue 4 | Pages 469 - 472
1 Aug 1982
Moulton A Upadhyay S

The measurements of the angle of anteversion of the femoral neck by ultrasound scanning is described. The method was compared with direct measurement in 30 dried femora, and was then used in 18 normal volunteers and eight patients. The method is non-invasive, accurate and easily applicable. Findings in normal subjects included variation of the angle of anteversion from 10 to 34 degrees with a maximal difference between sides of six degrees. The expected rotational deformity of the femur was found in patients with unilateral intoeing


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 3 | Pages 344 - 347
1 Mar 2012
Wu T Chen P Chen C Wang C

It is difficult to determine the safe timing of weight-bearing or reconstructive surgery in patients with Charcot arthropathy of the foot and ankle. In this study the Doppler spectrum of the first dorsal metatarsal artery was used to monitor the activity of the disease activity and served as a guideline for management. A total of 15 patients (seven men and eight women) with acute diabetic Charcot arthropathy of the foot and ankle were immobilised in a non-weight-bearing cast. They were followed at two-week intervals and bilateral Doppler spectra of the first dorsal metatarsal arteries were obtained using a 10 MHz linear ultrasound probe. The patients were allowed to start weight-bearing or undergo surgery after the Doppler spectrum had returned to normal pattern. The Doppler spectra in the unaffected limbs were triphasic in pattern, whereas those in limbs with active Charcot arthropathy showed monophasic forward flow. They returned to normal after a mean of 13.6 weeks (6 to 20) of immobilisation. Three patients underwent pan-talar arthrodesis to correct gross instability and deformity. Doppler spectrum analysis of the foot may reflect the activity of the disease in patients with Charcot arthropathy, and may be used as a guide to begin weight-bearing or undergo reconstructive surgery


The Journal of Bone & Joint Surgery British Volume
Vol. 81-B, Issue 5 | Pages 852 - 857
1 Sep 1999
Clegg J Bache CE Raut VV

We have analysed the patterns of management of developmental dysplasia of the hip (DDH) in Coventry over a period of 20 years during which three different screening policies were used. From 1976 to the end of 1985 we relied on clinical examination alone. The mean surgical cost for the treatment of DDH during this period was £5110 per 1000 live births. This was reduced to £3811 after the introduction of ultrasound for infants with known risk factors. Since June 1989 we have routinely scanned all infants at birth with a mean surgical cost of £468 per 1000 live births. This reduction in cost is a result of the earlier detection of DDH with fewer children requiring surgery. In those who do, fewer and less invasive procedures are needed. The overall rate of treatment has not increased and regular review of patients managed in a Pavlik harness has allowed us to avoid the complication of avascular necrosis. When we add the cost of running the screening programme to the expense of treating the condition, the overall cost for the management of DDH is comparable for the different screening policies


The Journal of Bone & Joint Surgery British Volume
Vol. 73-B, Issue 2 | Pages 207 - 210
1 Mar 1991
Krishna M Evans R Sprigg A Taylor J Theis J

Previous clinical studies have studied tibiofibular torsion by measuring the angular difference between a proximal (often bicondylar) plane and a distal bimalleolar plane. We measured the angular difference between the proximal and distal posterior tibial planes as defined by ultrasound scans. We found no significant torsional difference between the right and left tibiae of 87 normal children, nor between their different age groups. The mean external torsion of 58 legs with congenital talipes equinovarus was 18 degrees; significantly less than the mean 40 degrees in the normal children and 27 degrees in the clinically normal legs of the 22 patients with unilateral congenital talipes equinovarus. We did not confirm the previously reported increase in external torsion with increasing age. The relative internal tibial torsion we have demonstrated in patients with congenital talipes equinovarus must be differentiated from the posterior displacement of the distal fibula observed by others and which may result from manipulative treatment. The relative internal tibial torsion we found in the clinically normal legs of children with congenital talipes equinovarus is further evidence that in this condition the pathology is not confined to the clinically affected foot


The Journal of Bone & Joint Surgery British Volume
Vol. 76-B, Issue 3 | Pages 460 - 462
1 May 1994
Suzuki S

Ultrasound was used to observe the entire course of spontaneous reduction of CDH in the Pavlik harness in nine infants. In six infants with Suzuki type-A dislocations, the femoral head settled slowly into the bottom of the acetabulum by gliding on its posterior wall. In type-B dislocations, passive abduction of the legs during sleep caused it to approach the entrance to the socket and then suddenly to slip in. Reduction with the Pavlik harness is due to passive mechanical factors, and occurs only during muscle relaxation in deep sleep: no active movement is involved


The Journal of Bone & Joint Surgery British Volume
Vol. 78-B, Issue 3 | Pages 484 - 487
1 May 1996
Gleeson AP Stuart MJ Wilson B Phillips B

We studied 45 children who presented with an inversion injury of the ankle. The clinical signs suggested injury to the distal growth plate of the fibula, but the plain radiographs appeared normal. Ultrasound examination of the joint in 40 patients showed a subperiosteal haematoma consistent with a growth-plate injury in 23 (57.5%). Children who had been treated with a tubular bandage and crutches by random selection had a mean time to return of normal activity of 14.22 days compared with 21.60 days for those treated with a plaster-of-Paris cast (t = 3.60, p = 0.0032; d = 7.38, 95% CI 3.0 to 11.8). We conclude that children with inversion ankle injuries who have clinical signs of injury to the distal fibular growth plate but a normal radiological appearance, should be treated with a tubular bandage and crutches


The Journal of Bone & Joint Surgery British Volume
Vol. 72-B, Issue 3 | Pages 457 - 459
1 May 1990
Jones D Powell N

We describe a simple, quick ultrasound screening test for CDH, and its use in a prospective study of babies with a 'high risk' factor, over one year from January 1987. From a birth population of 3,879, 812 hip scans were performed on 406 babies and 98 babies were abnormal. So far, there have been no late cases of CDH. Family history, breech malposition, and postural foot deformities were confirmed to be important risk factors, but babies with a simple click were equally at risk. Our early results indicate that a large proportion of the potential late cases are contained within our extended high-risk group


The Journal of Bone & Joint Surgery British Volume
Vol. 86-B, Issue 4 | Pages 585 - 589
1 May 2004
Wirth T Stratmann L Hinrichs F

Between 1985 and 1998, 12 331 patients were included in the general neonatal ultrasound hip screening programme for developmental dysplasia of the hip (DDH). Patients who needed treatment (604) were compared with a second group of 73 unscreened children treated conservatively and surgically for DDH. The incidence of Graf sonographic hip types IIc to IV varied throughout the observation period. Femoral and pelvic osteotomies were almost entirely restricted to the unscreened group of patients. The six to ten per year recorded in the period 1985 to 1990 declined subsequently to three or less per year. The yearly admissions to hospital fell noticeably after six years of screening. Late presentations of DDH were reduced to three or less per year from 1990 to 1994, none between 1995 and 1998 and one or two per year from 2000. We conclude that general neonatal sonographic hip screening can reduce significantly surgical procedures, hospitalisation and late presentation of DDH


The Journal of Bone & Joint Surgery British Volume
Vol. 76-B, Issue 6 | Pages 918 - 921
1 Nov 1994
Warwick D Martin A Glew D Bannister G

We examined ten femoral veins with duplex ultrasound during total hip replacement to demonstrate the operative manoeuvres which cause venous obstruction and to assess prophylactic measures which may overcome it. Exposure of the acetabulum by distraction of the femur with a hook was less likely to occlude flow than retraction with bone levers. Adequate exposure of the femoral shaft by adduction, flexion and either internal or external rotation caused cessation of flow in all cases. In four cases an A-V Impulse System foot pump was activated during periods of stasis. In each case it overcame the obstruction and produced peak velocities which were twice that of the resting state. In five cases, towards the end of the procedure, debris was seen travelling proximally through the femoral vein


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 8 | Pages 1045 - 1048
1 Aug 2008
Shetty AA Tindall AJ James KD Relwani J Fernando KW

The diagnosis of a meniscal tear may require MRI, which is costly. Ultrasonography has been used to image the meniscus, but there are no reliable data on its accuracy. We performed a prospective study investigating the sensitivity and specificity of ultrasonography in comparison with MRI; the final outcome was determined at arthroscopy. The study included 35 patients with a mean age of 47 years (14 to 73).

There was a sensitivity of 86.4% (95% confidence interval (CI) 75 to 97.7), a specificity of 69.2% (95% CI 53.7 to 84.7), a positive predictive value of 82.6% (95% CI 70 to 95.2) and a negative predictive value of 75% (95% CI 60.7 to 81.1) for ultrasonography. This compared favourably with a sensitivity of 86.4% (95% CI 75 to 97.7), a specificity of 100.0%, a positive predictive value of 100.0% and a negative predictive value of 81.3% (95% CI 74.7 to 87.9) for MRI.

Given that the sensitivity matched that of MRI we feel that ultrasonography can reasonably be applied to confirm the clinical diagnosis before undertaking arthroscopy. However, the lower specificity suggests that there is still a need to improve the technique to reduce the number of false-positive diagnoses and thus to avoid unnecessary arthroscopy.


The Bone & Joint Journal
Vol. 99-B, Issue 1 | Pages 87 - 93
1 Jan 2017
Lawrence JE Nasr P Fountain DM Berman L Robinson AHN

Aims

This prospective cohort study aims to determine if the size of the tendon gap following acute rupture of the Achilles tendon shows an association with the functional outcome following non-operative treatment.

Patients and Methods

All patients presenting within two weeks of an acute unilateral rupture of the Achilles tendon between July 2012 and July 2015 were considered for the study. In total, 38 patients (nine female, 29 male, mean age 52 years; 29 to 78) completed the study. Dynamic ultrasound examination was performed to confirm the diagnosis and measure the gap between ruptured tendon ends. Outcome was assessed using dynamometric testing of plantarflexion and the Achilles tendon Total Rupture score (ATRS) six months after the completion of a rehabilitation programme.


The Journal of Bone & Joint Surgery British Volume
Vol. 77-B, Issue 4 | Pages 664 - 665
1 Jul 1995
Akerman M Bauer H Rydholm A Soderlund V


The Bone & Joint Journal
Vol. 96-B, Issue 6 | Pages 795 - 799
1 Jun 2014
Gamo K Kuriyama K Higuchi H Uesugi A Nakase T Hamada M Kawai H

We examined the outcomes and levels of patient satisfaction in 202 consecutive cases of ultrasound-guided supraclavicular brachial plexus block (SBPB) in upper limb surgery performed between September 2007 and March 2010.

All blocks were performed by orthopaedic surgeons using ultrasound visualisation with a high-frequency linear probe. The probe was placed in the coronal–oblique plane in the supraclavicular fossa, and the puncture was ‘in-plane’ from lateral to medial. Most of the blocks were performed with 0.75% ropivacaine/1% lidocaine (1:1), with or without adrenaline in 1:200 000 dilution. In 201 patients (99.5%) the brachial plexus block permitted surgery without conversion to general anaesthesia. The mean procedure time for block was 3.9 min (2 to 12), the mean waiting time for surgery was 34.1 min (10 to 64), the mean surgical time was 75.2 min (6 to 232), and the mean duration of post-anaesthetic analgesia was 437 min (171 to 992). A total of 20 patients (10%) developed a transient Horner’s syndrome. No nerve injury, pneumothorax, arterial puncture or systemic anaesthetic toxicity were recorded. Most patients (96.7%) were satisfied with ultrasound-guided SBPB. This study demonstrates the efficacy and safety of ultrasound-guided SBPB for orthopaedic surgery on the upper limb.

Cite this article: Bone Joint J 2014;96-B:795–9.


The Journal of Bone & Joint Surgery British Volume
Vol. 76-B, Issue 2 | Pages 337 - 338
1 Mar 1994
Eyres K Bell M


The Journal of Bone & Joint Surgery British Volume
Vol. 74-B, Issue 4 | Pages 488 - 494
1 Jul 1992
O'Keeffe D Mamtora H


The Journal of Bone & Joint Surgery British Volume
Vol. 72-B, Issue 4 | Pages 726 - 727
1 Jul 1990
Terjesen T Anda S


The Bone & Joint Journal
Vol. 95-B, Issue 6 | Pages 846 - 850
1 Jun 2013
Price KR Dove R Hunter JB

Most centres in the United Kingdom adopt a selective screening programme for developmental dysplasia of the hip (DDH) based on repeated clinical examination and selective ultrasound examination. The Newborn Infant Physical Examination protocol implemented in 2008 recommends a first examination at birth and then a second and final examination at six to ten weeks of age. Due to concerns over an increase in late presentations we performed a retrospective review of our 15-year results to establish if late presentation increases treatment requirements. Of children presenting before six weeks of age, 84% were treated successfully with abduction bracing, whereas 86% of children presenting after ten months eventually required open reduction surgery. This equates to a 12-fold increase in relative risk of requiring open reduction following late presentation. Increasing age at presentation was associated with an increase in the number of surgical procedures, which are inevitably more extensive and complex, with a consequent increased in cost per patient. The implementation of an opportunistic examination at three to five months could help to reduce the unintended consequences of the Newborn Infant Physical Examination programme.

Cite this article: Bone Joint J 2013;95-B:846–50.


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 1 | Pages 104 - 106
1 Jan 2006
Falliner A Schwinzer D Hahne H Hedderich J Hassenpflug J

In a prospective study, 232 neonates were examined sonographically using the methods of Graf and Terjesen. In order to determine the reproducibility of the methods, 50 hips were evaluated by two skilled examiners. In an inter-observer study, five physicians and five medical students evaluated 24 images, which were evaluated on ten occasions at two-weekly intervals by one of the authors. Statistical evaluation used the Bland-Altman approach.

The neonates (110 females, 122 males) were less than four days old. The mean α angle was 62.4° and mean femoral head cover was 55.4%. According to Graf’s method, 1.3% of hips were pathological, compared with 4.1% according to Terjesen. Spearman’s correlation coefficient between femoral head cover and α angles was 0.552. The Bland-Altman approach shows greater variation for femoral head cover than for α, if measured by experienced examiners. The Bland-Altman approach shows almost equal reproducibility for α and femoral head cover in the inter-observer test, but better repeatability for α in the intra-observer test.

The Graf results relate better than Terjesen’s to the well-known frequency of 1% to 2% hip dysplasia in the European population. Kappa statistics indicate a fair agreement between the two methods. Inter-observer evaluation shows an equal reproducibility of both methods, whereas intra-observer tests reveal better repeatability with Graf’s method.


The Journal of Bone & Joint Surgery British Volume
Vol. 81-B, Issue 6 | Pages 944 - 951
1 Nov 1999
Allen GM Wilson DJ


The Journal of Bone & Joint Surgery British Volume
Vol. 79-B, Issue 2 | Pages 342 - 342
1 Mar 1997
DODENHOFF RM


The Journal of Bone & Joint Surgery British Volume
Vol. 76-B, Issue 5 | Pages 688 - 689
1 Sep 1994
Johnstone A Beggs I


The Journal of Bone & Joint Surgery British Volume
Vol. 73-B, Issue 1 | Pages 175 - 176
1 Jan 1991
Howard C Einhorun M


The Journal of Bone & Joint Surgery British Volume
Vol. 70-B, Issue 1 | Pages 150 - 150
1 Jan 1988
Magnussen P Crozier A Gregg P


The Bone & Joint Journal
Vol. 95-B, Issue 2 | Pages 266 - 270
1 Feb 2013
Uludag S Seyahi A Orak MM Bilgili MG Colakoglu B Demirhan M

Several authors have suggested that the final five weeks of gestation are a critical period for the development of the hip. In order to test the hypothesis that gestational age at birth may influence the development of the hip joint, we analysed the sonographic findings in 1992 hips (in 996 term newborns) with no risk factor for developmental dysplasia of the hip. The 996 infants were born at a mean gestational age of 39 weeks (37 to 41).

The mean bony roof angle (α), cartilage roof angle (β) and the distribution of the type of hip were compared between the 37th, 38th, 39th, 40th and 41st birth week groups. There was a significant difference in the distribution of type of hip between the different birth week groups (p < 0.001), but no significant difference between the α angles of all groups (p = 0.32). There was no correlation between birth week and roof angle (p = 0.407 and p = 0.291, respectively) and no significant correlation between birth weight and roof angle (p = 0.735 and p = 0.132, respectively).

The maturity of the infant hip, as assessed sonographically, does not appear to be affected by gestational age, and the fetal development of the acetabular roof appears to plateau from 37 weeks.

Cite this article: Bone Joint J 2013;95-B:266–70.


The Journal of Bone & Joint Surgery British Volume
Vol. 82-B, Issue 3 | Pages 465 - 465
1 Apr 2000
Fogelman I


The Journal of Bone & Joint Surgery British Volume
Vol. 81-B, Issue 6 | Pages 1083 - 1084
1 Nov 1999
WILLIAMS P


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 1 | Pages 135 - 136
1 Jan 2005
PATON RW MUMTAZ H


The Journal of Bone & Joint Surgery British Volume
Vol. 83-B, Issue 3 | Pages 462 - 463
1 Apr 2001
CHESNEY D


The Journal of Bone & Joint Surgery British Volume
Vol. 77-B, Issue 3 | Pages 504 - 505
1 May 1995
Kerr P Silver D Telford K Andrews H Atkins R


The Journal of Bone & Joint Surgery British Volume
Vol. 82-B, Issue 4 | Pages 619 - 619
1 May 2000
SAMPATH JS PATON RW


The Journal of Bone & Joint Surgery British Volume
Vol. 73-B, Issue 3 | Pages 518 - 519
1 May 1991
Mathie A Benson M Wilson D


Bone & Joint Open
Vol. 5, Issue 1 | Pages 3 - 8
2 Jan 2024
Husum H Hellfritzsch MB Maimburg RD Møller-Madsen B Henriksen M Lapitskaya N Kold S Rahbek O

Aims. The present study seeks to investigate the correlation of pubofemoral distances (PFD) to α angles, and hip displaceability status, defined as femoral head coverage (FHC) or FHC during manual provocation of the newborn hip < 50%. Methods. We retrospectively included all newborns referred for ultrasound screening at our institution based on primary risk factor, clinical, and PFD screening. α angles, PFD, FHC, and FHC at follow-up ultrasound for referred newborns were measured and compared using scatter plots, linear regression, paired t-test, and box-plots. Results. We included 2,735 newborns, of whom 754 received a follow-up hip ultrasound within six weeks of age. After exclusion, 1,500 hips were included for analysis. Sex distribution was 372 male and 380 female, and the mean age at examination was 36.6 days (4 to 87). We found a negative linear correlation of PFD to α angles (p < 0.001), FHC (p < 0.001), and FHC during provocation (p < 0.001) with a 1 mm increase in PFD corresponding to a -2.1° (95% confidence interval (CI) -2.3 to -1.9) change in α angle and a -3.4% (95% CI -3.7 to -3.0) change in FHC and a -6.0% (-6.6 to -5.5) change in FHC during provocation. The PFD was significantly higher with increasing Graf types and in displaceable hips (p < 0.001). Conclusion. PFD is strongly correlated to both α angles and hip displaceability, as measured by FHC and FHC during provocation, in ultrasound of newborn hips. The PFD increases as the hips become more dysplastic and/or displaceable. Cite this article: Bone Jt Open 2023;5(1):3–8


The Bone & Joint Journal
Vol. 103-B, Issue 6 Supple A | Pages 18 - 22
1 Jun 2021
Omari AM Parcells BW Levine HB Seidenstein A Parvizi J Klein GR

Aims. The optimal management of an infrapopliteal deep venous thrombosis (IDVT) following total knee arthroplasty (TKA) remains unknown. The risk of DVT propagation and symptom progression must be balanced against potential haemorrhagic complications associated with administration of anticoagulation therapy. The current study reports on a cohort of patients diagnosed with IDVT following TKA who were treated with aspirin, followed closely for development of symptoms, and scanned with ultrasound to determine resolution of IDVT. Methods. Among a cohort of 5,078 patients undergoing TKA, 532 patients (695 TKAs, 12.6%) developed an IDVT between 1 January 2014 to 31 December 2019 at a single institution, as diagnosed using Doppler ultrasound at the first postoperative visit. Of the entire cohort of 532 patients with IDVT, 91.4% (486/532) were treated with aspirin (325 mg twice daily) and followed closely. Repeat lower limb ultrasound was performed four weeks later to evaluate the status of IDVT. Results. Follow-up Doppler ultrasound was performed on 459/486 (94.4%) patients and demonstrated resolution of IDVT in 445/459 cases (96.9%). Doppler diagnosed propagation of IDVT to the popliteal vein had occurred in 10/459 (2.2%) cases. One patient with an IDVT developed a pulmonary embolus six weeks postoperatively. Conclusion. The results of this study demonstrate a low rate of IDVT propagation in patients managed with aspirin. Additionally, no significant bleeding episodes, wound-related complications, or other adverse events were noted from aspirin therapy. Cite this article: Bone Joint J 2021;103-B(6 Supple A):18–22


Bone & Joint 360
Vol. 12, Issue 3 | Pages 43 - 43
1 Jun 2023
Das A

This edition of Cochrane Corner looks at some of the work published by the Cochrane Collaboration, covering interventions for treating distal femur fractures in adults; ultrasound and shockwave therapy for acute fractures in adults; and local corticosteroid injection versus placebo for carpal tunnel syndrome


Bone & Joint 360
Vol. 12, Issue 5 | Pages 42 - 45
1 Oct 2023

The October 2023 Children’s orthopaedics Roundup. 360. looks at: Outcomes of open reduction in children with developmental hip dislocation: a multicentre experience over a decade; A torn discoid lateral meniscus impacts lower-limb alignment regardless of age; Who benefits from allowing the physis to grow in slipped capital femoral epiphysis?; Consensus guidelines on the management of musculoskeletal infection affecting children in the UK; Diagnosis of developmental dysplasia of the hip by ultrasound imaging using deep learning; Outcomes at a mean of 13 years after proximal humeral fracture during adolescence; Clubfeet treated according to Ponseti at four years; Controlled ankle movement boot provides improved outcomes with lower complications than short leg walking cast


The Bone & Joint Journal
Vol. 106-B, Issue 3 | Pages 227 - 231
1 Mar 2024
Todd NV Casey A Birch NC

The diagnostic sub-categorization of cauda equina syndrome (CES) is used to aid communication between doctors and other healthcare professionals. It is also used to determine the need for, and urgency of, MRI and surgery in these patients. A recent paper by Hoeritzauer et al (2023) in this journal examined the interobserver reliability of the widely accepted subcategories in 100 patients with cauda equina syndrome. They found that there is no useful interobserver agreement for the subcategories, even for experienced spinal surgeons. This observation is supported by the largest prospective study of the treatment of cauda equina syndrome in the UK by Woodfield et al (2023). If the accepted subcategories are unreliable, they cannot be used in the way that they are currently, and they should be revised or abandoned. This paper presents a reassessment of the diagnostic and prognostic subcategories of cauda equina syndrome in the light of this evidence, with a suggested cure based on a more inclusive synthesis of symptoms, signs, bladder ultrasound scan results, and pre-intervention urinary catheterization. Cite this article: Bone Joint J 2024;106-B(3):227–231


The Bone & Joint Journal
Vol. 105-B, Issue 2 | Pages 209 - 214
1 Feb 2023
Aarvold A Perry DC Mavrotas J Theologis T Katchburian M

Aims. A national screening programme has existed in the UK for the diagnosis of developmental dysplasia of the hip (DDH) since 1969. However, every aspect of screening and treatment remains controversial. Screening programmes throughout the world vary enormously, and in the UK there is significant variation in screening practice and treatment pathways. We report the results of an attempt by the British Society for Children’s Orthopaedic Surgery (BSCOS) to identify a nationwide consensus for the management of DDH in order to unify treatment and suggest an approach for screening. Methods. A Delphi consensus study was performed among the membership of BSCOS. Statements were generated by a steering group regarding aspects of the management of DDH in children aged under three months, namely screening and surveillance (15 questions), the technique of ultrasound scanning (eight questions), the initiation of treatment (19 questions), care during treatment with a splint (ten questions), and on quality, governance, and research (eight questions). A two-round Delphi process was used and a consensus document was produced at the final meeting of the steering group. Results. A total of 60 statements were graded by 128 clinicians in the first round and 132 in the second round. Consensus was reached on 30 out of 60 statements in the first round and an additional 12 in the seond. This was summarized in a consensus statement and distilled into a flowchart to guide clinical practice. Conclusion. We identified agreement in an area of medicine that has a long history of controversy and varied practice. None of the areas of consensus are based on high-quality evidence. This document is thus a framework to guide clinical practice and on which high-quality clinical trials can be developed. Cite this article: Bone Joint J 2023;105-B(2):209–214


The Bone & Joint Journal
Vol. 105-B, Issue 9 | Pages 946 - 952
1 Sep 2023
Dhawan R Young DA Van Eemeren A Shimmin A

Aims. The Birmingham Hip Resurfacing (BHR) arthroplasty has been used as a surgical treatment of coxarthrosis since 1997. We present 20-year results of 234 consecutive BHRs performed in our unit. Methods. Between 1999 and 2001, there were 217 patients: 142 males (65.4%), mean age 52 years (18 to 68) who had 234 implants (17 bilateral). They had patient-reported outcome measures collected, imaging (radiograph and ultrasound), and serum metal ion assessment. Survivorship analysis was performed using Kaplan-Meier estimates. Revision for any cause was considered as an endpoint for the analysis. Results. Mean follow-up was 20.9 years (19.3 to 22.4). Registry data revealed that 19 hips (8.1%) had been revised and 26 patients (12%) had died from causes unrelated to the BHR. Among the remaining 189 hips, 61% were available for clinical follow-up at 20 years (n = 115) and 70% of patients had biochemical follow-up (n = 132). The cumulative implant survival rate at 20 years for male patients was 96.5% (95% confidence interval (CI) 93.5 to 99.6), and for female patients 87% (95% CI 79.7 to 94.9). The difference was statistically significant (p = 0.029). The mean Oxford Hip Score, Hip disability and Osteoarthritis Outcome Score, and Forgotten Joint Score were 45 (29 to 48), 89 (43 to 100), and 84 (19 to 100), respectively. The mean scores for each of the five domains of the EuroQol five-dimension three-level questionnaire were 1.2, 1.0, 1.2, 1.3, and 1.1, and mean overall score 82.6 (50 to 100). Ultrasound showed no pseudotumour. Mean cobalt and chromium levels were 32.1 nmol/l (1 to 374) and 45.5 nmol/l (9 to 408), respectively. Conclusion. This study shows that BHRs provide excellent survivorship and functional outcomes in young male patients. At 20 years, soft-tissue imaging and serum metal ion studies suggest that a metal-on-metal resurfacing implant can be well tolerated in a group of young patients. Cite this article: Bone Joint J 2023;105-B(9):946–952


The Bone & Joint Journal
Vol. 103-B, Issue 5 | Pages 991 - 998
1 May 2021
Lyu X Chen T Yang Z Fu G Feng C Zhang T Lu M

Aims. The objective of this study was to evaluate the clinical and radiological outcomes of patients younger than six months of age with developmental dysplasia of the hip (DDH) managed by either a Pavlik harness or Tübingen hip flexion splint. Methods. Records of 251 consecutive infants with a mean age of 89 days (SD 47), diagnosed with DDH between January 2015 and December 2018, were retrospectively reviewed. Inclusion criteria for patients with DDH were: younger than 180 days at the time of diagnosis; ultrasound Graf classification of IIc or greater; treatment by Pavlik harness or Tübingen splint; and no prior treatment history. All patients underwent hip ultrasound every seven days during the first three weeks of treatment and subsequently every three to four weeks until completion of treatment. If no signs of improvement were found after three weeks, the Pavlik harness or Tübingen splint was discontinued. Statistical analysis was performed. Results. The study included 251 patients with Graf grades IIc to IV in 18 males and 233 females with DDH. Mean follow-up time was 22 months (SD 10). A total of 116 hips were graded as Graf IIc (39.1%), nine as grade D (3.0%), 100 as grade III (33.7%), and 72 as grade IV (24.2%). There were 109 patients (128 hips) in the Pavlik group and 142 patients (169 hips) in the Tübingen group (p = 0.227). The Tübingen group showed a 69.8% success rate in Graf III and Graf IV hips while the success rate was significantly lower in the Pavlik group, 53.9% (p = 0.033). For infants older than three months of age, the Tübingen group showed a 71.4% success rate, and the Pavlik group a 54.4% success rate (p = 0.047). Conclusion. The Tübingen splint should be the preferred treatment option for children older than three months, and for those with severe forms of DDH such as Graf grade III and IV, who are younger than six months at time of diagnosis. The Tübingen hip flexion splint is a valid alternative to the Pavlik harness for older infants and those with more severe DDH. Cite this article: Bone Joint J 2021;103-B(5):991–998


The Bone & Joint Journal
Vol. 105-B, Issue 3 | Pages 231 - 238
1 Mar 2023
Holme TJ Crate G Trompeter AJ Monsell FP Bridgens A Gelfer Y

Aims. The ‘pink, pulseless hand’ is often used to describe the clinical situation in which a child with a supracondylar fracture of the humerus has normal distal perfusion in the absence of a palpable peripheral pulse. The management guidelines are based on the assessment of perfusion, which is difficult to undertake and poorly evaluated objectively. The aim of this study was to review the available literature in order to explore the techniques available for the preoperative clinical assessment of perfusion in these patients and to evaluate the clinical implications. Methods. A systematic literature review was conducted using the Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines and registered prospectively with the International Prospective Register of Systematic Reviews. Databases were explored in June 2022 with the search terms (pulseless OR dysvascular OR ischaemic OR perfused OR vascular injury) AND supracondylar AND (fracture OR fractures). Results. A total of 573 papers were identified as being suitable for further study, and 25 met the inclusion criteria for detailed analysis. These studies included a total of 504 patients with a perfused, pulseless limb associated with a supracondylar humeral fracture. Clinical examination included skin colour (23 studies (92%)), temperature (16 studies (64%)), and capillary refill time (13 studies (52%)). Other investigations included peripheral oxygen saturation (SaO2) (six studies (24%)), ultrasound (US) (14 (56%)), and CT angiogram (two studies (8.0%)). The parameters of ‘normal perfusion’ were often not objectively defined. The time to surgery ranged from 1.5 to 12 hours. A total of 412 patients (82%) were definitively treated with closed or open reduction and fixation, and 92 (18%) required vascular intervention, ranging from simple release of entrapped vessels to vascular grafts. Conclusion. The description of the vascular assessment of the patient with a supracondylar humeral fracture and a pulseless limb in the literature is variable, with few objective criteria being used to define perfusion. The evidence base for decision-making is limited, and further research is required. We were able, however, to make some recommendations about objective criteria for the assessment of these patients, and we suggest that these are performed frequently to allow the detection of any deterioration of perfusion. Cite this article: Bone Joint J 2023;105-B(3):231–238


The Bone & Joint Journal
Vol. 102-B, Issue 4 | Pages 495 - 500
1 Apr 2020
Milligan DJ Cosgrove AP

Aims. To monitor the performance of services for developmental dysplasia of the hip (DDH) in Northern Ireland and identify potential improvements to enhance quality of service and plan for the future. Methods. This was a prospective observational study, involving all infants treated for DDH between 2011 and 2017. Children underwent clinical assessment and radiological investigation as per the regional surveillance policy. The regional radiology data was interrogated to quantify the use of ultrasound and ionizing radiation for this population. Results. Evidence-based changes were made to the Northern Ireland screening programme, including an increase in ultrasound scanning capacity and expansion of nurse-led screening clinics. The number of infant hip ultrasound scans increased from 4,788 in 2011, to approximately 7,000 in 2013 and subsequent years. The number of hip radiographs on infants of less than one year of age fell from 7,381 to 2,208 per year. There was a modest increase in the treatment rate from 10.9 to 14.3 per 1,000 live births but there was a significant reduction in the number of closed hip reductions. The incidence of infants diagnosed with DDH after one year of age was 0.30 per 1,000 live births over the entire period. Conclusion. Improving compliance with the regional infant hip screening protocols led to reduction in operative procedures and reduced the number of pelvic radiographs of infants. We conclude that performance monitoring of screening programmes for DDH is essential to provide a quality service. Cite this article: Bone Joint J 2020;102-B(4):495–500


The Bone & Joint Journal
Vol. 101-B, Issue 6 | Pages 635 - 638
1 Jun 2019
Marson BA Hunter JB Price KR

Aims. The aim of this study was to review the value of accepting referrals for children with ‘clicky hips’ in a selective screening programme for hip dysplasia. Patients and Methods. A single-centre prospective database of all referrals to the hip clinic was examined to identify indication for referrals, diagnosis, and treatment. All patients referred received a standardized ultrasound scan and clinical examination by an orthopaedic consultant. Results. There were 5716 children referred to the orthopaedic hip clinic between 1 June 2014 and 26 September 2018. In all, 1754 children (30.1%) were referred due to ‘clicky hip’ with no additional risk factors or indications for ultrasound scan. A total of 123 children (7.1%) referred with ‘clicky hip’ and no additional risk factors or examination findings had an abnormal initial hip ultrasound, including 16 children (0.9%) with dysplastic hips. Of the 141 children who required treatment in a Pavlik harness during the study period, 23 (16%) had been referred with a ‘clicky hip’ and no additional risk factors or examination findings, including six children with Graf 3 or 4 hips. Conclusion. There is significant value in reviewing children with an isolated ‘clicky hip’. Many children who require treatment are referred to the orthopaedic service as ‘clicky hip’ with no additional risk factors. In a pragmatic pathway with a diverse population of clinicians performing baby checks, ‘clicky hip’ is an important indication for referral and should not be discarded. Cite this article: Bone Joint J 2019;101-B:635–638


The Bone & Joint Journal
Vol. 105-B, Issue 5 | Pages 487 - 495
1 May 2023
Boktor J Wong F Joseph VM Alshahwani A Banerjee P Morris K Lewis PM Ahuja S

Aims. The early diagnosis of cauda equina syndrome (CES) is crucial for a favourable outcome. Several studies have reported the use of an ultrasound scan of the bladder as an adjunct to assess the minimum post-void residual volume of urine (mPVR). However, variable mPVR values have been proposed as a threshold without consensus on a value for predicting CES among patients with relevant symptoms and signs. The aim of this study was to perform a meta-analysis and systematic review of the published evidence to identify a threshold mPVR value which would provide the highest diagnostic accuracy in patients in whom the diagnosis of CES is suspected. Methods. The search strategy used electronic databases (PubMed, Medline, EMBASE, and AMED) for publications between January 1996 and November 2021. All studies that reported mPVR in patients in whom the diagnosis of CES was suspected, followed by MRI, were included. Results. A total of 2,115 studies were retrieved from the search. Seven fulfilled the inclusion criteria. These included 1,083 patients, with data available from 734 being available for meta-analysis. In 125 patients, CES was confirmed by MRI. The threshold value of mPVR reported in each study varied and could be categorized into 100 ml, 200 ml, 300 ml, and 500 ml. From the meta-analysis, 200 ml had the highest diagnostic accuracy, with 82% sensitivity (95% confidence interval (CI) 0.72 to 0.90) and 65% specificity (95% CI 0.70 to 0.90). When compared using summative receiver operating characteristic curves, mPVR of 200 ml was superior to other values in predicting the radiological confirmation of CES. Conclusion. mPVR is a useful tool when assessing patients in whom the diagnosis of CES is suspected. Compared with other values a mPVR of 200 ml had superior sensitivity, specificity, and positive and negative predictive values. In a patient with a suggestive history and clinical findings, a mPVR of > 200 ml should further raise the suspicion of CES. Caution is recommended when considering the mPVR in isolation and using it as an ‘exclusion tool’, and it should only be used as an adjunct to a full clinical assessment. Cite this article: Bone Joint J 2023;105-B(5):487–495