Advertisement for orthosearch.org.uk
Results 1 - 16 of 16
Results per page:
Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_2 | Pages 13 - 13
1 Feb 2020
Tanaka S Tei K Minoda M Matsuda S Takayama K Matsumoto T Kuroda R
Full Access

Introduction

Acquiring adaptive soft-tissue balance is one of the most important factors in total knee arthroplasty (TKA). However, there have been few reports regarding to alteration of tolerability of varus/valgus stress between before and after TKA. In particular, there is no enough data about mid-flexion stability. Based on these backgrounds, it is hypothesized that alteration of varus/valgus tolerance may influence post-operative results in TKA. The purpose of this study is an investigation of in vivo kinematic analyses of tolerability of varus/valgus stress before and after TKA, comparing to clinical results.

Materials and Methods

A hundred knees of 88 consecutive patients who had knees of osteoarthritis with varus deformity were investigated in this study. All TKAs (Triathlon, Stryker) were performed using computer assisted navigation system. The kinematic parameters of the soft-tissue balance, and amount of coronal relative movement between femur and tibia were obtained by interpreting kinematics, which display graphs throughout the range of motion (ROM) in the navigation system. Femoro-tibial alignments were recorded under the stress of varus and valgus before the procedure and after implantation of all components. In each ROM (0, 30, 60, 90, 120 degrees), the data of coronal relative movement between femur and tibia (tolerability) were analyzed before and after implantation. Furthermore, correlations between tolerability of varus/valgus and clinical improvement revealed by ROM and Knee society score (KSS) were analyzed by logistic regression analysis.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_6 | Pages 48 - 48
1 Mar 2017
Tei K Minoda M Shimizu T Matsuda S Matsumoto T Kurosaka M Kuroda R
Full Access

Introduction

Recently, tibial insert design of cruciate-substituting (CS) polyethylene insert is employed and widely used. However, in vivo kinematics of using CS polyethylene insert is still unclear. In this study, it is hypothesized that CS polyethylene insert leads to stability of femoro-tibial joint as well as posterior-stabilized (PS) polyethylene insert, even if PCL is sacrificed after TKA. The purpose of this study is an investigation of in vivo kinematics of femoro-tibial joint with use of CS polyethylene insert before and after PCL resction using computer assisted navigation system and tensor device intra-operatively in TKA.

Materials and Methods

Sixty-one consecutive patients who had knees of osteoarthritis with varus deformity were investigated in this study. All TKAs (Triathlon, Stryker) were performed using computer assisted navigation system. During surgery, using a tensor device, after bony cut of femur and tibia, joint gaps were assessed in 0 and 90 degrees in flexion. Then, CS polyethylene tibial trial insert were inserted after trial implantation of femoral and tibial components, before and after resection of PCL, respectively. The kinematic parameters of the soft-tissue balance, and amount of coronal and sagittal relative movement between femur and tibia were obtained by interpreting kinematics, which display tables throughout the range of motion (ROM) in the navigation system. In each ROM (30, 45, 60, 90, max degrees), the data were analyzed with a ANOVA test, and mean values were compared by the multiple comparison test (Turkey HSD test) (p< 0.05).


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_4 | Pages 56 - 56
1 Feb 2017
Kawata T Goto K So K Kuroda Y Okuzu Y Matsuda S
Full Access

Introduction

The long-term wear performance of highly cross-linked polyethylene (HXLPE) in cemented total hip arthroplasty (THA) has rarely been reported. Here we report a prospective randomized comparative analysis of radiographic wear after a minimum follow-up of 10 years in cemented THAs with either HXLPE or conventional polyethylene (CPE), and assess its clinical relevance.

Patients and Methods

From 1999 to 2001, we conducted 94 primary cemented THAs with a 22.225-mm head at our hospital as part of a prospective randomized trial. All surgeries were performed using a direct lateral approach with a trochanteric osteotomy (Dall's approach). The patients were divided into 4 groups. Twenty-six hips in group A were implanted with CPE sockets against zirconia heads and Charnley-type stems. HXLPE sockets (Aeonian, Kyocera Medical Corp) were implanted in all hips in the other 3 groups. Twenty-five hips in group B were implanted with zirconia heads and KC stems (Kyocera Medical Corp), 23 hips in group C with zirconia heads and distal cylindrical stems, and 20 hips in group D with stainless steel heads and C-stem (DePuy Inc). The sockets were highly cross-linked by gamma irradiation at a dose of 35 kGy, heat annealed at 110ºC, and sterilized with 25 kGy of gamma irradiation in nitrogen.

For radiographic evaluation, anteroposterior radiograms were taken for each patient annually, and every two years postoperatively for wear analyses. Two-dimensional head penetration was measured on each postoperative radiogram using a computer-aided technique.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_10 | Pages 45 - 45
1 May 2016
So K Kuroda Y Goto K Matsuda S
Full Access

Introduction

Total hip arthroplasty (THA) for a highly dislocated hip can be problematic and technically challenging. Our previous study on cemented THA with subtrochanteric femoral shortening osteotomy revealed a high incidence (20%) of non-union. Therefore, in 2008, we introduced reverse hybrid THA using S-ROM stem for the treatment of a highly dislocated hip. The purpose of this study was to assess the short-term clinical outcomes of this new method.

Patients and methods

Between 2008 and 2014, 13 consecutive reverse hybrid THAs were performed on nine female patients with highly dislocated hips. The average age at the time of operation was 66 years (range, 55–85 years). The acetabular component was fixed in the true acetabulum with bone cement. Transverse osteotomy was performed below the lesser trochanter to shorten the femur and to prevent over-lengthening. The proximal sleeve of the S-ROM stem was then fixed within the proximal fragment, and the distal fin provided rotational stability of the distal fragment. Thus, the two fragments were fixed to each other with the S-ROM stem, and the resected segment was longitudinally cut for grafting at the junction. The postoperative follow-up period was an average of 4 years (range, 1–7 years), and no patients were lost. Preoperative and final Japanese Orthopaedic Association (JOA) hip score, operation time, bleeding amount, intraoperative and postoperative complications, bone healing at the osteotomy site, implant loosening, and revision surgery were retrospectively investigated.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_8 | Pages 5 - 5
1 May 2016
Goto K So K Kuroda Y Okuzu Y Matsuda S
Full Access

Background

Composite screws of uncalcined and unsintered hydroxyapatite (HA) particles and poly-l-lactide (PLLA) were developed as completely absorbable bone fixation devices. So far the durability of HA-PLLA composite screws is unclear when used for the fixation of acetabular bone graft in total hip arthroplasty under full-weight conditions. We have used this type of screw for the fixation of acetabular bone graft in cemented or reverse-hybrid total hip arthroplasty since 2003. Hence, we conducted a follow-up study to assess the safety and efficacy of these screws when used for cemented socket fixation.

Methods

During 2003–2009, HA-PLLA composite screws were used for fixation of acetabular bone graft in cemented or reverse-hybrid primary THA in 106 patients (114 cases). All the THAs were performed through direct lateral approaches, and postoperative gait exercise with full weight bearing usually started two days after surgery. One patient died of an unrelated disease and seven patients were lost to follow-up within 5 years. Finally, 98 patients (106 cases) were followed up for over 5 years and were reviewed retrospectively (follow-up rate, 93%). Radiographic loosening of the acetabular component was assessed according to the criteria of Hodgkinson et al., and the radiolucent line around the socket was evaluated in all zones, as described by DeLee and Charnley.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_3 | Pages 26 - 26
1 Jan 2016
Matsuda S
Full Access

Introduction

Genu recurvatum deformities are unusual before total knee arthroplasty (TKA), occurring in less than 1% of patients. The purpose of this study is to evaluate the clinical and radiographic results of primary TKA in patients that had recurvatum deformities before surgery.

Patients and Methods

The inclusion criteria was to have recurvatum deformity over 10 degrees on lateral standing X-ray view. We retrospectively reviewed 22 knees with pre-operative recurvatum deformities, and the incident was 1.0% of all TKAs at our hospital. The etiology of the arthritis was osteoarthritis in 21 knees, of which 3 knees were neuropathic disease, and rheumatoid arthritis in 1 knee. There were 6 men and 16 women, and the average age was 73.3 years (range, 53 to 83 years) at the time of operation. The average follow-up period was 15 months (range, 3 to 81 months). We performed to use medial parapatellar approach and bone cutting was done by measured resection technique. The surgical knacks were resection of less distal femur and proximal tibia bone to make extension gap tightly, additionally decrease the tibial posterior slope. Posterior-stabilizer (PS) implants (NexGen LPS: Zimmer, Bisurface KU4+: JMM) were used in 20 knees and constrained implants (NexGen RH knee: Zimmer, Endo-Model Hinge Knee: Link) were in 2 knees with neuropathic joints.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_2 | Pages 65 - 65
1 Jan 2016
Ito H Ogino H Furu M Ishikawa M Matsuda S
Full Access

Background

Total elbow arthroplasty (TEA) has become an established procedure in the treatment of patients with rheumatoid arthritis (RA). However, there is little information on whether limited extension of the elbow affects clinical outcome scores after TEA and what causes the limited extension.

Methods

We retrospectively analyzed fifty-four cases of primary TEA in patients with RA. There were seven men and thirty-nine women with a mean age of 63.6 years (range, thirty to eighty years). Thirty-seven of Coonrad-Morrey and seventeen of Discovery prostheses were used. The mean length of follow-up was 7.1 ± 4.0 years (range 2.0–14.6 years). Mayo Elbow Performing Score (MEPS) and radiological measurements were recorded. Anteroposterior and lateral radiographs were assessed before and after the operation and at the latest follow-up. Widening of the joint space was calculated by subtracting the length measured on the postoperative radiograph from that on the preoperative radiograph.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_2 | Pages 8 - 8
1 Jan 2016
Goto K Fuyuya Y Masayuki S Matsuda S
Full Access

Postoperative peritrochanteric pain, which can be caused by non-union of the greater trochanter in those who have undergone total hip arthroplasty (THA) with trochanteric osteotomy, affects patient satisfaction. We reviewed 89 consecutive cases of primary THA performed with a mini-trochanteric direct lateral approach (Wafer approach), during which the anteroinferior trochanteric fragment (2 cm × 1 cm) attached to the anterior one-third or one-fourth of the gluteus medius muscle insertion and the entire insertion of the gluteus minimus muscle were osteotomized and detached using a curved chisel for exposure, while the origin of the vastus lateralis muscle remained intact. After completion of implantation, the detached fragment was fixed in the original position using 2 parallel braided sutures. If returning the trochanteric fragment to its original position was difficult, the tightened posterior tendinous portion of the gluteus minimus muscle was released to reduce the fragment easily and was then fixed. The surgeries, which included 19 cemented, 7 cementless, and 63 hybrid THAs, were performed between January 2012 and August 2013, and the patients [13 men, 76 women; average age, 65.6 years (38–86 years)] were followed for 6 months. The original diagnosis included primary osteoarthritis in 7 cases, osteoarthritis secondary to dysplasia in 75 cases, and avascular necrosis of the femoral head in 7 cases. X-ray examination including anteroposterior (AP) and lateral hip views was performed at 1, 3, and 6 months postoperatively, and a displacement of > 5 mm of the osteotomized fragment in either the AP or lateral view was considered fragment migration. The Japanese Orthopaedic Association (JOA) pain score was also recorded at 3 and 6 months postoperatively. We examined the possible factors affecting trochanteric migration and JOA pain score, including age, sex, THA type, leg lengthening, Crowe classification, and suture type. We also examined the correlation between trochanteric migration and JOA pain score. There were no peri- or post-operative complications including infection, deep venous thrombosis, dislocation, or periprosthetic fracture. No revision or radiographic loosening occurred in the follow-up period. Average leg lengthening was 9.8 mm (−4–21 mm), measured on the AP X-ray of the hip as the vertical interval between the pre- and postoperative positions of the lesser trochanter. There were 35 cases (39.3%) of trochanteric migration at postoperative 3 months. The Chi-square test and logistic regression analysis indicated that age, sex, Crowe classification, leg lengthening, and suture type did not affect trochanteric migration or JOA pain score. On the other hand, THA type did not affect trochanteric migration but did affect JOA pain score at postoperative 3 months. Patients who underwent cementless THA had worse JOA pain scores than the other patients. There was no correlation between trochanteric migration and JOA pain scores. The results indicated that trochanteric fragment migration often occurred in this series using the Wafer approach. Although the pain score is affected by many factors including thigh pain, hip abductor weakness, and wound irritation in the short term, it did not correlate with the trochanteric nonunion rate of this approach.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_2 | Pages 131 - 131
1 Jan 2016
Kuroda Y Manabu N So K Goto K Akiyama H Matsuda S
Full Access

Introduction

Ultra-high molecular weight polyethylene (UHMWPE) tape, which comprised threads of UHMWPE fibers with the thickness less than 0.5 mm, was developed as a flexible fixation device. We describe new techniques using UHMWPE tape for the reattachment of the osteotomised fragment and the repair of intraoperative calcar fractures in total hip arthroplasty (THA).

Patients & Methods

We reviewed the medical records and radiographs of the studied subjects after approval of this study by the institutional review board committee. Experiment 1: Between October 2011 and May 2012, 60 consecutive primary THAs were performed with the mini-trochanteric approach, which involved reattaching the osteotomised fragment using UHMWPE tape (Nesplon; Alfresa Pharma, Osaka, Japan). [Fig.1] By splitting the anterior one-fourth of the gluteus medius, the minitrochanteric osteotomy, a half-ellipsoid body about 15 mm long, 10 mm wide, and 5 mm deep, is performed using a curved chisel. After implanting of the prosthesis, the osteotomised fragment is reattached by using two 3-mm wide Nesplon tapes. Using 2.4 mm Kirshner wire, two sets of drill holes are created below the trochanteric bed of the femur. Nesplon tapes are passed through each drill hole and penetrated over the trochanteric fragment. Nesplon tape is tied using a double-loop sliding knot in conjunction with a special tightening gun tensioner up to 20 kgf. [Fig.2] The radiographic results were retrospectively analyzed to determine the incidence of nonunion and complications related to trochanteric site. Hip functional results were rated according to the Japanese Orthopedic Association (JOA) hip score. Experiment 2: Between July 2011 and May 2012, 5-mm wide Nesplon tapes were used for restoration of intraoperative femoral fractures in 4 primary THAs. For the repair of intraoperative proximal femoral fractures, 5-mm wide Nesplon tape is tightened with cerclage wiring technique using the gun tensioner up to 30 kgf. [Fig.3] The postoperative radiographic changes were analyzed.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_2 | Pages 130 - 130
1 Jan 2016
Kuriyama S Ishikawa M Nakamura S Furu M Ito H Matsuda S
Full Access

Introduction

Malrotation of the tibial component would lead to various complications after total knee arthroplasty (TKA) such as improper joint kinematics, patellofemoral instability, or excessive wear of polyethylene. However, despite reports of internal rotation of the tibial component being associated with more severe pain or stiffness than external rotation, the biomechanical reasons remain largely unknown. In this study, we used a musculoskeletal computer model to simulate a squat (0°–130°–0° flexion) and analyzed the effects of malrotated tibial component on lateral and medial collateral ligament (LCL and MCL) tensions, tibiofemoral and patellofemoral contact stresses, during the weight-bearing deep knee flexion.

Materials and Methods

A musculoskeletal model, replicating the dynamic quadriceps-driven weight-bearing knee flexion in previous cadaver studies, was simulated with a posterior cruciate-retaining TKA. The model included tibiofemoral and patellofemoral contact, passive soft tissue and active muscle elements. The soft tissues were modeled as nonlinear springs using previously reported stiffness parameters, and the bony attachments were also scaled to some cadaver reports. The neutral rotational alignment of the femoral and tibial components was aligned according to the femoral epicondylar axis and the tibial anteroposterior axis, respectively. Knee kinematics and ligament tensions were computed during a squat for malrotated conditions of the tibial component. The tibial rotational alignments were changed from 15° external rotation to 15° internal rotation in 5° increments. The MCL and LCL tensions, the tibiofemoral and patellofemoral contact stresses were compared among the knees with different rotational alignment.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_2 | Pages 64 - 64
1 Jan 2016
Ishikawa M Kuriyama S Furu M Matsuda S
Full Access

Objective

Kinematically aligned total knee arthroplasty (TKA) is of increasing interest because this method may improve patient satisfaction. However, the biomechanics of kinematically aligned TKA remain largely unknown. Therefore, we analyzed whether the kinematic alignment method cause to increase the contact force on patellofemoral and tibiofemoral joints.

Methods

A musculoskeletal computer simulation was used to determine the effects of kinematically or mechanically aligned TKA. Patellofemoral and tibiofemoral contact forces were examined for a mechanically aligned model and a kinematically aligned model using finite element analysis.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_4 | Pages 19 - 19
1 Jan 2016
So K Kuroda Y Goto K Matsuda S
Full Access

Introduction

In order to reduce polyethylene wear and incidence of osteolysis, and improve the long-term durability of total hip arthroplasty (THA), highly cross-linked polyethylene was introduced for clinical use in substitution for conventional polyethylene. We performed 35 cementless THAs between December 2000 and February 2002, and cross-linked polyethylene was used in these surgeries. The purpose of this study is to research linear wear rate of these hips, and to find the risk factor for high wear rate.

Patients and Methods

32 hips (26 patients) among the 35 could be evaluated at more than 10 years postoperatively. One hip required reoperations due to infection at 8 years postoperatively, and two were lost to followup in less than 10 years. There were 2 males and 24 females, and the observation period was 11.4 years in average (range 10?13 years). The age at the time of operation was 49.4 years in average (range 24?67 years), and body mass index was 22.4 in average (15?34). We used AHFIX total hip prostheses (KYOCERA Medical Corporation) for both acetabular and femoral replacement, and 22 mm Zirconia head was used in all cases. The median cup diameter was 46 mm (range 42?50). Osteolysis and loosening of the implant was evaluated on the anteroposterior radiograph of the hip. Using software for wear measurement (Hip Analysis Suite), linear wear rate and cup inclination angle were measured. Correlation between linear wear rate and age, BMI, cup inclination angle, and cup diameter was investigated using correlation coefficient.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_3 | Pages 47 - 47
1 Jan 2016
Mizu-uchi H Okazaki K D'Lima D Hamai S Okamoto S Iwamoto Y Matsuda S
Full Access

Introduction

Using the tibial extramedullary guide needs meticulous attention to accurately align the tray in total knee arthroplasty (TKA). We previously reported the risk for varus tray alignment if the anteroposterior (AP) axis of the ankle was used for the rotational direction of the guide. The purpose of our study was to determine whether aligning the rotational direction of the guide to the AP axis of the proximal tibia reduced the incidence of varus tray alignment when compared to aligning the rotational direction of the guide to the AP axis of the ankle.

Materials and Methods


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_3 | Pages 75 - 75
1 Jan 2016
Nakamura S Sharma A Nakamura K Ikeda N Zingde S Komistek R Matsuda S
Full Access

Previously more femoral rollback has been reported in posterior-stabilized implants, but so far the kinematic change after post-cam engagement has been still unknown. The tri-condylar implants were developed to fit a life style requiring frequent deep flexion activities, which have the ball and socket third condyle as post-cam mechanism. The purpose of the current study was to examine the kinematic effects of the ball and socket third condyle during deep knee flexion.

The tri-condylar implant analyzed in the current study is the Bi-Surface Knee System developed by Kyocera Medical (Osaka, Japan). Seventeen knees implanted with a tri-condylar implant were analyzed using 3D to 2D registration approach. Each patient was asked to perform a weight-bearing deep knee bend from full extension to maximum flexion under fluoroscopic surveillance. During this activity, individual fluoroscopic video frames were digitized at 10°increments of knee flexion. A distance of less than 1 mm initially was considered to signify the ball and socket contact. The translation rate as well as the amount of translation of medial and lateral AP contact points and the axial rotation was compared before and after the ball and socket joint contact.

The average angle of ball and socket joint contact were 64.7° (SD = 8.7), in which no separation was observed after initial contact. The medial contact position stayed from full extension to ball and socket joint contact and then moved posteriorly with knee flexion. The lateral contact position showed posterior translation from full extension to ball and socket joint contact, and then greater posterior translation after contact (Figure 1). Translation and translation rate of contact positions were significantly greater at both condyles after ball and socket joint contact. The femoral component rotated externally from full extension to ball and socket joint contact, and then remained after ball and socket joint contact (Figure 2). There was no statistical significance in the angular rotation between ball and socket joint contact and maximum flexion. Translation of angular rotation was significantly greater before ball and socket joint contact, however, there was no significance in translation rate before and after ball and socket joint contact.

The ball and socket joint was proved to induce posterior rollback intensively. In terms of axial rotation, the ball and socket joint did not induce reverse rotation, but had slightly negative effects after contact. The ball and socket provided enough functions as a posterior stabilizing post-cam mechanism and did not prevent axial rotation.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_1 | Pages 144 - 144
1 Jan 2016
Furu M Ishikawa M Kuriyama S Nakamura S Azukizawa M Hamamoto Y Ito H Matsuda S
Full Access

Purpose

Total knee arthroplasty (TKA) is one of the most successful surgeries with respect to relieving pain and restoring function of the knee. However, some studies have reported that patients are not always satisfied with their results after TKA. The aim of this study was to determine which factors contribute to patient's satisfaction after TKA.

Methods

We evaluated 69 patients who had undergone 76 primary TKAs between March 2012 and June 2013, and assessed patient- and physician- reported scores using the 2011 Knee Society Scoring System and clinical variables before and after TKAs. We determined the correlation between patient satisfaction and clinical variables.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXV | Pages 37 - 37
1 Jun 2012
Mizu-Uchi H Flores-Hernandez C Colwell C Steklov N Matsuda S Iwamoto Y D'Lima D
Full Access

INTRODUCTION

Knee contact force during activities after total knee arthroplasty (TKA) is very important, since it directly affects component wear and implant loosening. While several computational models have predicted knee contact force, the reports vary widely based on the type of modeling approach and the assumptions made in the model. The knee is a complex joint, with three compartments of which stability is governed primarily by soft tissues. Multiple muscles control knee motion with antagonistic co-contraction and redundant actions, which adds to the difficulty of accurate dynamic modeling. For accurate clinically relevant predictions a subject-specific approach is necessary to account for inter-patient variability.

METHODS

Data were collected from 3 patients who received custom TKA tibial prostheses instrumented with force transducers and a telemetry system. Knee contact forces were measured during squatting, which was performed up to a knee flexion angle that was possible without discomfort (range, 80–120°). Skin marker-based video motion analysis was used to record knee kinematics. Preoperative CT scans were reconstructed to extract tibiofemoral bone geometry using MIMICS (Materialise, Belgium). Subject-specific musculoskeletal models of dynamic squatting were generated in a commercial software program (LifeMOD, LifeModeler, USA). Contact was modeled between tibiofemoral and patellofemoral articular surfaces and between the quadriceps and trochlear groove to simulate tendon wrapping. Knee ligaments were modeled with nonlinear springs: the attachments of these ligaments were adjusted to subject-specific anatomic landmarks and material properties were assigned from published reports.