Advertisement for orthosearch.org.uk
Orthopaedic Proceedings Logo

Receive monthly Table of Contents alerts from Orthopaedic Proceedings

Comprehensive article alerts can be set up and managed through your account settings

View my account settings

Visit Orthopaedic Proceedings at:

Loading...

Loading...

Full Access

General Orthopaedics

TOTAL KNEE ARTHROPLASTY IN PATIENTS WITH GENU RECURVATUM

The International Society for Technology in Arthroplasty (ISTA), 27th Annual Congress. PART 3.



Abstract

Introduction

Genu recurvatum deformities are unusual before total knee arthroplasty (TKA), occurring in less than 1% of patients. The purpose of this study is to evaluate the clinical and radiographic results of primary TKA in patients that had recurvatum deformities before surgery.

Patients and Methods

The inclusion criteria was to have recurvatum deformity over 10 degrees on lateral standing X-ray view. We retrospectively reviewed 22 knees with pre-operative recurvatum deformities, and the incident was 1.0% of all TKAs at our hospital. The etiology of the arthritis was osteoarthritis in 21 knees, of which 3 knees were neuropathic disease, and rheumatoid arthritis in 1 knee. There were 6 men and 16 women, and the average age was 73.3 years (range, 53 to 83 years) at the time of operation. The average follow-up period was 15 months (range, 3 to 81 months). We performed to use medial parapatellar approach and bone cutting was done by measured resection technique. The surgical knacks were resection of less distal femur and proximal tibia bone to make extension gap tightly, additionally decrease the tibial posterior slope. Posterior-stabilizer (PS) implants (NexGen LPS: Zimmer, Bisurface KU4+: JMM) were used in 20 knees and constrained implants (NexGen RH knee: Zimmer, Endo-Model Hinge Knee: Link) were in 2 knees with neuropathic joints.

Results

The averaged Knee Society Knee and Function score improved from 33.1 points to 94.1 points, and 28.0 points to 60.5 points at the time of the last follow-up. The femorotibial angle changed from averaged 183.4 degrees (range, 162 to 195 degrees) preoperatively to averaged 173.3 degrees (range, 170 to 177 degrees).

Preoperative hyperextension was averaged 18.2 degrees (range, 10 to 40 degrees). Intraoperatively, the hyperextension deformity was corrected in all cases. The tibial posterior slope was averaged 1.7 degrees (range, −2.7 to 6 degrees). The final hyperextension improved averaged 6.9 degrees (range, −1.7 to 26.6 degrees), all but one knee were corrected. One case treated with a standard PS type, who was associated with neuropathic disease, had a recurrence of recurvatum deformity and required revision surgery.

Discussion

Recurvatum may be associated with a severe osseous deformity, capsular or ligamentous laxity, and neuromuscular disease. Surgical solutions may be to use a standard PS prosthesis with a slight underresection of the bone edge, and decrease tibial posterior slope. An alternative solution is to use a rotating-hinge prosthesis with less than antigravity quadriceps strength for neuromuscular disease.


Email: