Advertisement for orthosearch.org.uk
Results 1 - 13 of 13
Results per page:
The Bone & Joint Journal
Vol. 101-B, Issue 6_Supple_B | Pages 91 - 96
1 Jun 2019
Smith A Denehy K Ong KL Lau E Hagan D Malkani A

Aims. Cephalomedullary nails (CMNs) are commonly used for the treatment of intertrochanteric hip fractures. Total hip arthroplasty (THA) may be used as a salvage procedure when fixation fails in these patients. The aim of this study was to analyze the complications of THA following failed intertrochanteric hip fracture fixation using a CMN. Patients and Methods. Patients who underwent THA were identified from the 5% subset of Medicare Parts A/B between 2002 and 2015. A subgroup involving those with an intertrochanteric fracture that was treated using a CMN during the previous five years was identified and compared with the remaining patients who underwent THA. The length of stay (LOS) was compared using both univariate and multivariate analysis. The incidence of infection, dislocation, revision, and re-admission was compared between the two groups, using multivariate analysis adjusted for demographic, hospital, and clinical factors. Results. The Medicare data yielded 56 522 patients who underwent primary THA, of whom 369 had previously been treated with a CMN. The percentage of THAs that were undertaken between 2002 and 2005 in patients who had previously been treated with a CMN (0.346%) more than doubled between 2012 and 2015 (0.781%). The CMN group tended to be older and female, and to have a higher Charlson Comorbidity Index and lower socioeconomic status. The mean LOS was 1.5 days longer (5.3 vs 3.8) in the CMN group (p < 0.0001). The incidence of complications was significantly higher in the CMN group compared with the non-CMN group: infection (6.2% vs 2.6%), dislocation (8.1% vs 4.5%), revision (8.4% vs 4.3%), revision for infection (1.1% vs 0.37%), and revision for dislocation (2.2% vs 0.6%). Conclusion. The incidence of conversion to THA following failed intertrochanteric hip fracture fixation using a CMN continues to increase. This occurs in elderly patients with increased comorbidities. There is a significantly increased risk of infection, dislocation, and LOS in these patients. Patients with failed intertrochanteric hip fracture fixation using a CMN who require THA should be made aware of the increased risk of complications, and steps need to be taken to reduce this risk. Cite this article: Bone Joint J 2019;101-B(6 Supple B):91–96


Bone & Joint Research
Vol. 6, Issue 5 | Pages 270 - 276
1 May 2017
Gosiewski JD Holsgrove TP Gill HS

Objectives. Fractures of the proximal femur are a common clinical problem, and a number of orthopaedic devices are available for the treatment of such fractures. The objective of this study was to assess the rotational stability, a common failure predictor, of three different rotational control design philosophies: a screw, a helical blade and a deployable crucifix. Methods. Devices were compared in terms of the mechanical work (W) required to rotate the implant by 6° in a bone substitute material. The substitute material used was Sawbones polyurethane foam of three different densities (0.08 g/cm. 3. , 0.16 g/cm. 3. and 0.24 g/cm. 3. ). Each torsion test comprised a steady ramp of 1°/minute up to an angular displacement of 10°. Results. The deployable crucifix design (X-Bolt), was more torsionally stable, compared to both the dynamic hip screw (DHS, p = 0.008) and helical blade (DHS Blade, p= 0.008) designs in bone substitute material representative of osteoporotic bone (0.16 g/cm. 3. polyurethane foam). In 0.08 g/cm. 3. density substrate, the crucifix design (X-Bolt) had a higher resistance to torsion than the screw (DHS, p = 0.008). There were no significant differences (p = 0.101) between the implants in 0.24 g/cm. 3. density bone substitute. Conclusions. Our findings indicate that the clinical standard proximal fracture fixator design, the screw (DHS), was the least effective at resisting torsional load, and a novel crucifix design (X-Bolt), was the most effective design in resisting torsional load in bone substitute material with density representative of osteoporotic bone. At other densities the torsional stability was also higher for the X-Bolt, although not consistently significant by statistical analysis. Cite this article: J. D. Gosiewski, T. P. Holsgrove, H. S. Gill. The efficacy of rotational control designs in promoting torsional stability of hip fracture fixation. Bone Joint Res 2017;6:270–276. DOI: 10.1302/2046-3758.65.BJR-2017-0287.R1


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_11 | Pages 13 - 13
7 Jun 2023
Diffley T Ferry J Sumarlie R Beshr M Chen B Clement N Farrow L
Full Access

Appropriate surgical management of hip fractures has major clinical and economic consequences. Recently IMN use has increased compared to SHS constructs, despite no clear evidence demonstrating superiority of outcome. We therefore set out to provide further evidence about the clinical and economic implications of implant choice when considering hip fracture fixation strategies. A retrospective cohort study using Scottish hip fracture audit (SHFA) data was performed for the period 2016–2022. Patients ≥50 with a hip fracture and treated with IMN or SHS constructs at Scottish Hospitals were included. Comparative analyses, including adjustment for confounders, were performed utilising Multivariable logistic regression for dichotomous outcomes and Mann-Whitney-U tests for non-parametric data. A sub-group analysis was also performed focusing on AO-A1/A2 configurations which utilised additional regional data. Cost differences in Length of Stay (LOS) were calculated using defined costs from the NHS Scotland Costs book. In all analyses p<0.05 denoted significance. 13638 records were included (72% female). 9867 received a SHS (72%). No significant differences were identified in 30 or 60-day survival (Odds Ratio [OR] 1.05, 95%CI 0.90–1.23; p=0.532), (OR 1.10, 95%CI 0.97–1.24; p=0.138) between SHS and IMN's. There was however a significantly lower early mobilisation rate with IMN vs SHS (OR 0.64, 95%CI 0.59–0.70; p<0.001), and lower likelihood of discharge to domicile by day-30 post-admission (OR 0.77, 95%CI 0.71–0.84; p<0.001). Acute and overall, LOS were significantly lower for SHS vs IMN (11 vs 12 days and 20 vs 24 days respectively; p<0.001). Findings were similar across a sub-group analysis of 559 AO A1/A2 fracture configurations. Differences in LOS potentially increases costs by £1230 per-patient, irrespective of the higher costs of IMN's v SHS. Appropriate SHS use is associated with early mobilisation, reduced LOS and likely with reduced cost of treatment. Further research exploring potential reasons for the identified differences in early mobilisation are warranted


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_14 | Pages 32 - 32
1 Nov 2021
Huo M
Full Access

Thru purpose of this study was to evaluate the clinical outcomes of a consecutive series of conversion total hip arthroplasty (cTHA) following previous hip fractures. A retrospective chart review of patients who underwent cTHAs from 2008–2017 at an urban academic teaching institution was performed. Eighty-eight patients were included in this study. The mean age at the cTHA was 66 years (range 27 to 89). 67% of the patients wre women. The mean BMI was 28 kg/m. 2. (range 17 to 41). The mean Charlson Comorbidity Index was 3 (range 0 to 9). The mean follow-up was 49 months (range 24 to 131). The mean duration from the hip fracture fixation to the cTHA was 51 months (range 10 to 144). The mean operating time was 188 minutes, (range 71 to 423) with a mean estimated blood loss of 780 ml (range 300 to 2500). Revision-type (long-stem) designs were used in 65% of the cases. The mean length of hospital stay was 8 days (range 2 to 61). The readmission rate was 37% within 90 days after the CTHAs. Of these, 57% were due to non-orthopaedic complications. There were 10 orthopaedic complications: 7 PJIs, all of which required I&D and 3 required staged revision. There were 2 dislocations treated with closed reduction and 1 case of intraoperative periprosthetic femur fracture during femoral component insertion. There was no revision for aseptic loosening within the follow-up period. The one-year mortality rate was 0%. cTHAs were associated with longer operating time, more blood loss, longer length of hospital stay, and higher readmission rates than the primary THAs in our institutional database. We believe utilizing a multi-disciplinary care protocol to optimize these patients is needed to reduce the high rate of readmissions, and the complications in this patient population


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_16 | Pages 84 - 84
19 Aug 2024
Cordero-Ampuero J
Full Access

Debate continues about the best treatment for patients over 65 years with non-displaced subcapital hip fractures: internal fixation (IF) or hemiarthroplasty (HA). Surgical aggression, mortality, complications and recovery of walking ability after 1year have been compared between both treatments. Match-paired comparison of 2 retrospective cohorts. 220 patients with IF vs 220 receiving a cemented bipolar HA. Matching by age (82.6±7.16 years (65–99)), sex (74.5% women), year of intervention (2013–2021) and ASA scale (24.2% ASA II, 55.8% III, 20.0% IV). Age (p=0.172), sex (p=0.912), year of intervention (p=0.638) and ASA scale (p=0.726) showed no differences. Surgical aggression smaller in IF: Surgical time (p< 0,00001), haemoglobin/haematocrit loss (p <0,00001), need for transfusion (p<0,00008), in-hospital stay (p<0,00001). Mortality: higher in-hospital for hemiarthroplasties (12 deaths (5.5%) vs 1 (0.5%) (p=0.004) (RR=12, 1.5–91.5)). But no significant differences in 1-month (13 hemiarthroplasties, 6%, vs 9 osteosynthesis, 4.1%) and 1-year mortality (33 hemiarthroplasties, 15%, vs 35, 16%). Medical complications: no differences in urinary/respiratory infections, heart failure, ictus, myocardial infarction, digestive bleeding, pressure sores or pulmonary embolus (p=0.055). Surgical complications: no significant differences. HA: 6 intraoperative (2,7%) and 5 postoperative periprosthetic fractures (2,3%), 5 infections (2,3%), 10 dislocations (4,5%), 3 neurovascular injuries. IF: 10 acute fixation failures (4,5%), 2 infections (0,9%), 9 non-unions (4,1%), 16 ischemic necrosis (7,3%). Functional results: no significant differences; 12 patients in each group (5,5%) never walked again (p=1), 110 HA (50%) and 100 IF (45.5%) suffered worsening of previous walking ability (p=0.575), 98 HA (44%) and 108 IF patients (49%) returned to pre-fracture walking ability (p=0.339). Fixation with cannulated screws may be a better option for non-displaced femoral neck fractures because recovery of walking ability and complications are similar, while surgical aggression and in-hospital mortality are lower


Bone & Joint Open
Vol. 4, Issue 5 | Pages 329 - 337
8 May 2023
Khan AQ Chowdhry M Sherwani MKA McPherson EJ

Aims

Total hip arthroplasty (THA) is considered the preferred treatment for displaced proximal femoral neck fractures. However, in many countries this option is economically unviable. To improve outcomes in financially disadvantaged populations, we studied the technique of concomitant valgus hip osteotomy and operative fixation (VOOF). This prospective serial study compares two treatment groups: VOOF versus operative fixation alone with cannulated compression screws (CCSs).

Methods

In the first series, 98 hip fixation procedures were performed using CCS. After fluoroscopic reduction of the fracture, three CCSs were placed. In the second series, 105 VOOF procedures were performed using a closing wedge intertrochanteric osteotomy with a compression lag screw and lateral femoral plate. The alignment goal was to create a modified Pauwel’s fracture angle of 30°. After fluoroscopic reduction of fracture, lag screw was placed to achieve the calculated correction angle, followed by inter-trochanteric osteotomy and placement of barrel plate. Patients were followed for a minimum of two years.


Bone & Joint Open
Vol. 4, Issue 3 | Pages 168 - 181
14 Mar 2023
Dijkstra H Oosterhoff JHF van de Kuit A IJpma FFA Schwab JH Poolman RW Sprague S Bzovsky S Bhandari M Swiontkowski M Schemitsch EH Doornberg JN Hendrickx LAM

Aims

To develop prediction models using machine-learning (ML) algorithms for 90-day and one-year mortality prediction in femoral neck fracture (FNF) patients aged 50 years or older based on the Hip fracture Evaluation with Alternatives of Total Hip arthroplasty versus Hemiarthroplasty (HEALTH) and Fixation using Alternative Implants for the Treatment of Hip fractures (FAITH) trials.

Methods

This study included 2,388 patients from the HEALTH and FAITH trials, with 90-day and one-year mortality proportions of 3.0% (71/2,388) and 6.4% (153/2,388), respectively. The mean age was 75.9 years (SD 10.8) and 65.9% of patients (1,574/2,388) were female. The algorithms included patient and injury characteristics. Six algorithms were developed, internally validated and evaluated across discrimination (c-statistic; discriminative ability between those with risk of mortality and those without), calibration (observed outcome compared to the predicted probability), and the Brier score (composite of discrimination and calibration).


Bone & Joint Research
Vol. 6, Issue 4 | Pages 204 - 207
1 Apr 2017
Fernandez MA Aquilina A Achten J Parsons N Costa ML Griffin XL

Objectives. The Sliding Hip Screw (SHS) is commonly used to treat trochanteric hip fractures. Fixation failure is a devastating complication requiring complex revision surgery. One mode of fixation failure is lag screw cut-out which is greatest in unstable fracture patterns and when the tip-apex distance of the lag screw is > 25 mm. The X-Bolt Dynamic Hip Plating System (X-Bolt Orthopaedics, Dublin, Ireland) is a new device which aims to reduce this risk of cut-out. However, some surgeons have reported difficulty minimising the tip-apex distance with subsequent concerns that this may lead to an increased risk of cut-out. Patients and Methods. We measured the tip-apex distance from the intra-operative radiographs of 93 unstable trochanteric hip fractures enrolled in a randomised controlled trial (Warwick Hip Trauma Evaluation, WHiTE One trial). Participants were treated with either the sliding hip screw or the X-Bolt dynamic hip plating system. We also recorded the incidence of cut-out in both groups, at a median follow-up time of 17 months. Results. There was a significantly increased tip-apex distance with the use of the X-Bolt (mean difference 3.7mm (95% confidence interval 1.58 to 5.73); SHS mean 17.1 mm, X-Bolt mean 20.8; p = 0.001. However, this was not associated with an increased incidence of cut-out at a median follow-up time of 17 months, with three cut-outs (6%) in the SHS group and 0 (0%) in the X-Bolt group. Conclusion. The X-Bolt is a safe implant with no increased risk for cut-out. Concerns about minimising the tip-apex distance may be justified but do not appear to be clinically important. Cite this article: M. A. Fernandez, A. Aquilina, J. Achten, N. Parsons, M. L. Costa, X. L. Griffin. The tip-apex distance in the X-Bolt dynamic plating system. Bone Joint Res 2017;6:–207. DOI: 10.1302/2046-3758.64.BJR-2015-0016.R2


The Bone & Joint Journal
Vol. 102-B, Issue 12 | Pages 1675 - 1681
1 Dec 2020
Uzoigwe CE O'Leary L Nduka J Sharma D Melling D Simmons D Barton S

Aims

Postoperative delirium (POD) and postoperative cognitive decline (POCD) are common surgical complications. In the UK, the Best Practice Tariff incentivizes the screening of delirium in patients with hip fracture. Further, a National Hip Fracture Database (NHFD) performance indicator is the reduction in the incidence of POD. To aid in its recognition, we sought to determine factors associated with POD and POCD in patients with hip fractures.

Methods

We interrogated the NHFD data on patients presenting with hip fractures to our institution from 2016 to 2018. POD was determined using the 4AT score, as recommended by the NHFD and UK Department of Health. POCD was defined as a decline in Abbreviated Mental Test Score (AMTS) of two or greater. Using logistic regression, we adjusted for covariates to identify factors associated with POD and POCD.


The Bone & Joint Journal
Vol. 102-B, Issue 6 | Pages 693 - 698
1 Jun 2020
Viswanath A Malik A Chan W Klasan A Walton NP

Aims

Despite few good-quality studies on the subject, total hip arthroplasty (THA) is increasingly being performed for displaced intracapsular fractures of the neck of femur. We compared outcomes of all patients with displacement of these fractures treated surgically over a ten-year period in one institution.

Methods

A total of 2,721 patients with intracapsular fractures of the femoral neck treated with either a cemented hemiarthroplasty or a THA at a single centre were retrospectively reviewed. The primary outcomes analyzed were readmission for any reason and revision surgery. We secondarily looked at mortality rates.


The Bone & Joint Journal
Vol. 102-B, Issue 2 | Pages 191 - 197
1 Feb 2020
Gabor JA Padilla JA Feng JE Schnaser E Lutes WB Park KJ Incavo S Vigdorchik J Schwarzkopf R

Aims

Although good clinical outcomes have been reported for monolithic tapered, fluted, titanium stems (TFTS), early results showed high rates of subsidence. Advances in stem design may mitigate these concerns. This study reports on the use of a current monolithic TFTS for a variety of indications.

Methods

A multi-institutional retrospective study of all consecutive total hip arthroplasty (THA) and revision total hip arthroplasty (rTHA) patients who received the monolithic TFTS was conducted. Surgery was performed by eight fellowship-trained arthroplasty surgeons at four institutions. A total of 157 hips in 153 patients at a mean follow-up of 11.6 months (SD7.8) were included. Mean patient age at the time of surgery was 67.4 years (SD 13.3) and mean body mass index (BMI) was 28.9 kg/m2 (SD 6.5). Outcomes included intraoperative complications, one-year all-cause re-revisions, and subsidence at postoperative time intervals (two weeks, six weeks, six months, nine months, and one year).


Bone & Joint Research
Vol. 8, Issue 7 | Pages 313 - 322
1 Jul 2019
Law GW Wong YR Yew AK Choh ACT Koh JSB Howe TS

Objectives

The paradoxical migration of the femoral neck element (FNE) superomedially against gravity, with respect to the intramedullary component of the cephalomedullary device, is a poorly understood phenomenon increasingly seen in the management of pertrochanteric hip fractures with the intramedullary nail. The aim of this study was to investigate the role of bidirectional loading on the medial migration phenomenon, based on unique wear patterns seen on scanning electron microscopy of retrieved implants suggestive of FNE toggling.

Methods

A total of 18 synthetic femurs (Sawbones, Vashon Island, Washington) with comminuted pertrochanteric fractures were divided into three groups (n = 6 per group). Fracture fixation was performed using the Proximal Femoral Nail Antirotation (PFNA) implant (Synthes, Oberdorf, Switzerland; n = 6). Group 1 was subjected to unidirectional compression loading (600 N), with an elastomer (70A durometer) replacing loose fracture fragments to simulate surrounding soft-tissue tensioning. Group 2 was subjected to bidirectional loading (600 N compression loading, 120 N tensile loading), also with the elastomer replacing loose fracture fragments. Group 3 was subjected to bidirectional loading (600 N compression loading, 120 N tensile loading) without the elastomer. All constructs were tested at 2 Hz for 5000 cycles or until cut-out occurred. The medial migration distance (MMD) was recorded at the end of the testing cycles.


Bone & Joint Research
Vol. 3, Issue 11 | Pages 317 - 320
1 Nov 2014
Basso T Klaksvik J Foss OA

Objective

In ex vivo hip fracture studies femoral pairs are split to create two comparable test groups. When more than two groups are required, or if paired femurs cannot be obtained, group allocation according to bone mineral density (BMD) is sometimes performed. In this statistical experiment we explore how this affects experimental results and sample size considerations.

Methods

In a hip fracture experiment, nine pairs of human cadaver femurs were tested in a paired study design. The femurs were then re-matched according to BMD, creating two new test groups. Intra-pair variance and paired correlations in fixation stability were calculated. A hypothetical power analysis was then performed to explore the required sample size for the two types of group allocation.