Advertisement for orthosearch.org.uk
Results 1 - 20 of 29
Results per page:
The Bone & Joint Journal
Vol. 97-B, Issue 9 | Pages 1197 - 1203
1 Sep 2015
Kim Y Park J Kim J

A number of studies have reported satisfactory results from the isolated revision of an acetabular component. However, many of these studies reported only the short- to intermediate-term results of heterogeneous bearing surfaces in a mixed age group.

We present our experience of using a ceramic-on-ceramic (CoC) bearing for isolated revision of an uncemented acetabular component in 166 patients (187 hips) who were under the age of 50 years at the time of revision. There were 78 men and 88 women with a mean age of 47.4 years (28 to 49). The most common reason for revision was polyethylene wear and acetabular osteolysis in 123 hips (66%), followed by aseptic loosening in 49 hips (26%).

We report the clinical and radiological outcome, complication rate, and survivorship of this group. The mean duration of follow-up was 15.6 years (11 to 19).

The mean pre-operative Harris hip score was 33 points (1 to 58), and improved to a mean of 88 points (51 to 100) at follow-up. The mean pre-operative total Western Ontario and McMaster Universities Osteoarthritis Index score was 63.2 (43 to 91) and improved to 19.8 points (9 to 61) post-operatively. Overall, 153 of 166 patients (92%) were satisfied with their outcome. Kaplan–Meier survivorship analysis, with revision or radiological evidence of implant failure (13 patients, 8%) as end-points, was 92% at 15 years (95% confidence interval 0.89 to 0.97).

Isolated revision of a cementless acetabular component using a CoC bearing gives good results in patients under 50 years of age.

Cite this article: Bone Joint J 2015;97-B:1197–1203.


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_16 | Pages 54 - 54
19 Aug 2024
AlFayyadh F Neufeld ME Howard LC Masri BA Greidanus NV Garbuz D
Full Access

There remains concern with the use of constrained liners (CL) implanted at the time of acetabular cup revision in revision total hip replacement (rTHA). The aim of this study was to determine the implant survival in rTHA when a CL was implanted at the same time as acetabular cup revision. We reviewed our institutional database to identify all consecutive rTHAs where a CL was implanted simultaneously at the time acetabular cup revision from 2001 to 2021. One-hundred and seventy-four revisions (173 patients) were included in the study. Mean follow-up of 8.7 years (range two – 21.7). The most common indications for rTHA were instability (35%), second-stage periprosthetic joint infection (26.4%), and aseptic loosening (17.2%). Kaplan Meier Analysis was used to determine survival with all-cause re-revision and revision for cup aseptic loosening (fixation failure) as the endpoints. A total of 32 (18.3%) patients underwent re-revision at a mean time of 2.9 years (range 0.1 – 14.1). The most common reasons for re-revision were instability (14), periprosthetic joint infection (seven), and loosening of the femoral component (four). Three (1.7%) required re-revision due to aseptic loosening of the acetabular component (fixation failure) at a mean of two years (0.1 – 5.1). Acetabular component survival free from re-revision due to aseptic loosening was 98.9% (95% CI 97.3 – 100) at five-years and 98.1% (95% CI 95.8 – 100) at 10-years. There were no acetabular component fixation failures in modern highly porous shells. CLs implanted at the time acetabular cup revision in rTHA have a 98.1% 10-year survival free from acetabular cup aseptic loosening (fixation failure). There were no cup fixation failures in modern highly porous shells. Thus, when necessary, implanting a CL during revision of an acetabular component with stable screw fixation is safe with an extremely low risk of cup fixation failure


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_14 | Pages 19 - 19
1 Nov 2021
Schreurs B Kuijpers M van Steenbergen L Hannink G
Full Access

The increasing number of total hip arthroplasty (THA) used in young patients will inevitably lead to more revision procedures at younger ages, especially since the outcome of primary THA in young patients is already inferior compared to older patients. However, these data are lacking in literature. The aim of this study was to determine the survival of both acetabular and femoral components placed during primary and revision hip arthroplasty in patients under 55 years using Dutch Arthroplasty Register (LROI) data. All primary THA registered in the LROI between 2007–2018 in patients under 55 years were selected (n=25,682). Subsequent cup- and stem revision procedures were included. Kaplan-Meier survival analyses were used to estimate the survival probability of primary and revised cup- and stem components. Mean follow-up of primary cups and stems was 5.8 years (SD 3.2) and 5.9 years (SD 3.2), respectively. In total, 659 cup revision procedures and 532 stem revision procedures were registered. Most common reason for cup revision was acetabular loosening (n=163), most common reason for stem revision was femoral loosening (n=202). Primary cup survival for any reason at 10 years follow-up was 96.1% (95%CI: 95.7–96.4). For primary stems, 10 year survival for any reason was 97.1% (95%CI: 96.7–97.3). Mean follow-up of all revision procedures was 4.1 years (SD 2.9). Out of 659 cup revisions, 113 cup re-revisions were registered. Survival of revised cups, with end-point cup re-revision for any reason was 82.2% (95%CI: 78.8–85.1) at 5 years follow-up. Out of 532 stem revisions, 89 stem re-revisions were registered. For revised stems, survival at 5 year follow-up, with endpoint stem re-revision for any reason was 82.0% (95%CI: 78.2–85.2). The outcome of revised acetabular and femoral components is worrisome, with a survival of 82% at 5 years follow-up. This information is valuable to provide realistic expectations for these young patients at time of primary THA


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_12 | Pages 46 - 46
23 Jun 2023
Mallett K Guarin S Sierra RJ
Full Access

Dual mobility (DM) components are increasingly used to prevent and treat dislocation after total hip arthroplasty (THA). Intraprosthetic dissociation (IPD) is a known rare complication of these implants and has reportedly decreased with modern implants. The purpose of this paper is to report the diagnosis and treatment of modern DM IPD. 1453 DM components were implanted between 2010 and 2021. 695 in primary and 758 in revision THA. 49 hips sustained a dislocation of the large head and 5 sustained an IPD at presentation. 6 additional IPD occurred at the time of reduction of large head. The average age was 64, 54% were female and the mean follow-up was three years. Of the 11 IPD, 8 had a history of instability, 5 had abductor insufficiency, 4 had prior lumbar fusion, and 3 were conversions from fracture. The overall IPD incidence was 0.76%. Ten of the 11 DM IPD were missed at initial presentation or at the time of reduction, and all were discharged with presumed reduction. The mean time from IPD to surgical treatment was 3 weeks. One patient died with an IPD at 5 months. A DM head was reimplanted in six, two underwent revision of the acetabular component with exchange of DM head, and four were revised to a constrained liner. The re-revision rate was 55% at a mean 1.8 years. None of the patients who underwent cup revision required subsequent re-revision while half of the constrained liners and exchange of DM heads required re-revision. The overall rate of DM dislocation or IPD is low. It is critical to identify an IPD on radiographs as it was almost universally missed at presentation or when it occurred iatrogenically. For patients presenting with IPD, the surgeon should consider acetabular revision and conversion to a constrained liner or a larger DM, with special attention to removing impinging structures that could increase the risk of re-dislocation


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_16 | Pages 60 - 60
19 Aug 2024
Lau LCM Cheung MH Ng FY Fu H Chan PK Chiu P
Full Access

In total hip arthroplasty (THA), cementless cup without screw holes has the putative benefits of maximizing host bone contact and reducing osteolysis by eliminating channels to backside wear particles. However, supplemental trans-acetabular screws cannot be used. 74 hips in 60 patients receiving same model of cementless cup without screw holes (Depuy Duraloc 100 HA cup) from 6/1999 to 3/2003 were prospectively followed up. All patients were allowed to have immediate full weight bearing. Age at THA was 53 ± 13 (range 24–74) years. Osteonecrosis was the leading hip disease (45% of hips). Survivorship was assessed using revision of the cup as the end point. Radiological parameters, including lateral opening angle, vertical and horizontal migration distances of the cups were measured. Paired t-test was used to compare between the measurements in early postoperative period and at final follow up. 51 hips were assessed at minimum 20 years follow-up. The mean follow-up was 22.6 (range 21 – 25) years. All the cups were well fixed. There were two cup revisions. Conventional polyethylene (PE) was used in both hips; osteolysis occurred 17 and 18 years later. Both cups were well fixed but were revised, one due to cup mal-positioning, one due to need in upsizing the articulation. 14 other hips were revised but these cups were well fixed and not revised; 9 loosened stems (most were cemented Elite plus stems), 5 PE wear and osteolysis (all were conventional PE). At 20 years, the survivorship of cups was 96.1%. Changes in lateral opening angle, vertical and horizontal migration distances were 0.44±1.59°, 0.01±1.52mm and -0.32±1.47mm respectively, without statistical significance. This study provided evidence of excellent long-term survivorship of cementless cup without screw holes. Immediate postoperative weight-bearing also did not lead to cup migration in the long-term


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_16 | Pages 8 - 8
19 Aug 2024
Kärrholm J Itayem R Angelomenos V Mohaddes M Rogmark C Rolfson O
Full Access

In 2022, approximately 60% of inserted cups and stems in Sweden utilized cemented fixation. Two predominant brands, Refobacin Bone Cement R and Palacos R+G, both incorporating gentamicin, were employed in over 90% of primary cemented Total Hip Arthroplasties (THAs) between 2012 and 2022. This study investigates whether the choice between these cement types affects the risk of revision. The five most frequently used cemented cups and the three most common stems were studied. Inclusion criteria encompassed hips with non-tumour diagnoses, operated through a direct lateral or posterior incision, featuring a 28–36 mm metal or ceramic head. Outcomes were assessed for cup revisions (n=55,457 Refobacin, 37,210 Palacos), stem revisions (n=51,732 Refobacin, 30,018 Palacos), and all-cemented THAs with either brand (n=45,265 Refobacin, 26,347 Palacos). Kaplan-Meier life tables and hazard ratios (HR) utilizing Cox regression were computed, adjusting for age, sex, diagnosis, implant type, femoral head size, and material. Over a 10-year period, the cumulative percent revision with Refobacin was consistently higher than Palacos in all three analyses (cups: Refobacin 2.4 (2.3–2.5), Palacos 2.1 (2.0–2.2); stems: Refobacin 2.6 (2.5–2.7), Palacos 2.1 (2,0–2,2); all-cemented: Refobacin 3.2 (2.9–3.5), Palacos 2.9 (2.6–3.2)). Both unadjusted and adjusted HR were 13–25% lower with Palacos. In the analysis of all-cemented THAs, the adjusted HR for Palacos was 0.85 (0.76–0.95). Separating revisions into infectious and non-infectious reasons revealed a lower risk of infectious revisions with Palacos in all three analyses (all-cemented: adjusted HR infection 0.66 (0.56–0.78); non-infectious 1.10 (0.94–1.28)). Hips cemented with Refobacin may face an increased risk of infection, potentially due to a smaller release of antibiotics into surrounding tissues. Unaccounted factors like different mixing systems or unknown biases could also influence outcomes, emphasizing the need for further investigation


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_10 | Pages 36 - 36
1 Oct 2020
Hernandez NM Hinton ZW Wu CJ Lachiewicz PF Ryan SP Wellman SS
Full Access

Background. Modular dual mobility (MDM) acetabular components are often used to prevent dislocation in revision total hip arthroplasty (THA). As there is insufficient data on these components, the outcomes were evaluated in a cohort with a mean follow-up time of greater than five years. Methods. Using the database of a single academic center, 126 revision THAs (117 patients) with one MDM were retrospectively reviewed. There were 94 hips in 88 patients with a mean follow-up time of 5.5 years. Survivorship analysis was performed with the endpoints of dislocation, reoperation for dislocation, cup revision for aseptic loosening, and cup revision for any reason. The secondary endpoints were perioperative complications and radiographic review. Results. The overall rate of dislocation was 11%, with a 6-year survival of 91%. Reoperation for dislocation was performed in 7 patients (7%), with a 6-year survival of 94%. The dislocations were early (mean 33 days) in 6 patients, and late (mean 4.3 years) in 4 patients. There were three intraprosthetic dissociations. An outer head diameter of 48 mm or greater was associated with a lower risk of dislocation (p=0.013). Four hips (4%) were revised for aseptic cup loosening, and 14 (15%) cups were revised for infection. Two hips had visible metallic changes of the backside of the cobalt chromium liner. Conclusion. Using this MDM component in revision THA, at mean follow-up time of 5.5 years, there was a higher rate of dislocation (11%) than previously reported. Outer bearing size was related to the risk of dislocation. There was a low rate of aseptic cup loosening. Longer follow-up of this MDM component and evaluation of other designs is warranted


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_11 | Pages 23 - 23
1 Aug 2018
Sousa P Abdel M Francois E Hanssen A Lewallen D
Full Access

Highly porous tantalum cups have been used in complex acetabular revisions for nearly 20 years but reports of long term results are limited. This study was designed to report ten year results of revision using a single porous tantalum cup design with special attention to re-operation for any reason, all-cause revision, and revision for aseptic loosening. Retrospective review of all revision THA cases performed from 1999–2006 using a highly porous tantalum acetabular component design with multiple screw holes and a cemented polyethylene liner (Zimmer Biomet, Warsaw, IN). Our institutional medical record and total joint registry were used to assess follow-up and xrays were reviewed. The Paprosky classification system was used to rate acetabular bone loss. Radiographic loosening was defined as new/progressive radiolucencies in all 3 acetabular zones, or cup migration (>2mm). Kaplan-Meier survivorship was used to assess survivorship free of cup revision/removal for any reason, and free of revision for aseptic loosening. Between 1999 and 2006 this tantalum cup was used in 916 revisions. Mean age: 66 (±6), BMI: 29 (±6), and male: 42%. Indications for revision: aseptic loosening 346 (38%), osteolysis 240 (26%), and infected arthroplasty 168 (18%). Large (3A or 3B) bone defects were present in 260, and pelvic discontinuity in 61. Reoperation for any reason: 133 (15%), but 84 of 133 cases did not require cup revision for instability (38) or femoral failure (24). Tantalum cup removal/revision was required in 49 (5.3%) for deep infection (39) and recurrent dislocation (6), and aseptic loosening (4). 10 year survivorship free of cup revision for any reason: 95% and for aseptic loosening: 99%. Radiographic review (mean 10 years): suspicious for aseptic loosening in another 4 cups. A highly porous tantalum acetabular component with multiple screws and a cemented polyethylene insert provided durable long term fixation for an array of acetabular revision problems. Long term aseptic loosening was very rare (<1%) and cup removal was mainly related to deep infection, and rarely dislocation


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_14 | Pages 44 - 44
1 Nov 2021
Zhou Y
Full Access

With the approval of our institute, we reviewed all the robot-assisted hip revision during October 2019 and August 2021. MAKO joint arthroplasty system was used to perform the hip revision surgery. Seventy-one robot-assisted hip revision cases were included. Cup revisions were carried out in 68 patients while stem revisions were also carried out in 68 patients. Three types of registration techniques (extra acetabular bone surface based, liner based, metal shell based or cage surface based) on the acetabular side. The extra acetabular bone surface was the commonest used for registration (48/70, 68.6%, mean accuracy 0.37mm), followed by liner surface (11/70, 15.7%, mean accuracy 0.36mm), acetabulum cup (10/70, 14.3%, mean accuracy 0.37mm), and cage surface (1/70, 1.4%, accuracy 0.40mm). We succeeded cup registration and robotic arm guided cup insertion in all the cases. The average cup inclination and anteversion after revision were 40.87°±4.39° and 13.87°±4.24°, respectively. Cups in 62 cases (62/68, 91.2%) were within the Lewinnek safe zone while in 55 cases (55/68, 80.9%) were within the Callanan safe zone. The Mako robot-assisted system could bring favorable cup reconstruction in hip revision with acceptable surgical time and blood loss. Accurate registration could be achieved by different methods


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_14 | Pages 13 - 13
1 Nov 2021
Bizot P Kavakélis T Odri G
Full Access

The goal of the study was to describe the features of the aseptic loosening of the cup in CoC THR and to determine factors that affect the time to revision. It is a retrospective study including all patients who had a revision of CoC THR for aseptic failure fixation of the cup, between 2007 and 2017. 55 patients (27 women, 28 men) (56 hips) were included in the study. Eight hips (13 %) had also a stem exchange. At the primary T HR, the mean age of the patients was 47.9 years (17–72), 28 press fit cups had screws, the mean diameter of the cup was 51.2 mm (46–62) and the mean inclination was 52° (37–67). Clinical and radiological data were retrospectively recorded by an observer different to the initial operators. The mean age of the patients at the revision was 55.4 years (26–84). The mean time to revision was 90.1 months (14–240), and was significantly greater in patients aged less than 52 years, in cups without screws and with a 28mm head. The trend curve of the time to cup revision showed a bimodal distribution at three and ten years. 20 cups had migrated (33%). Bone loss was rated type 1 in 41 hips (73.0%), type 2 in 12 hips and type 3 in three hips). The mean diameter of the new cup was 52.3 mm (46–64). It was inferior to that of the initial cup in 26 hips (46.4%). 31 cups were impacted (55.5%) and 25 needed to be cemented (45.5%). No macroscopic wear was detected on the ceramic implant. Aseptic loosening of the cup in CoC THA does not appear to increase over time, supporting the fact that the failure is unrelated to wear and is not due to a biological mechanism. The occurrence of two peaks of frequency over time may suggest that different mechanisms occur


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_14 | Pages 12 - 12
1 Nov 2021
Cordero-Ampuero J Velasco P
Full Access

To compare complications, survivorship and results in 2 groups of Furlong-HAP Active, one with ceramic-ceramic and the other with metal-XLPE friction pair. Prospective, non-randomized, comparison of 2 series of JRI uncemented prosthesis, implanted with identical protocol by 1 surgeon in 1 hospital from 2006 to 2014. Friction pair was ceramic (Biolox Forte or Delta) in 35 patients of 53.7+/−10.6 years (25–69) (21 males, 60%), and CrCo-XLPE in 65 cases of 69.0+/−8.9 years (42–81) (36 males, 55%); there were significant differences in age (p<0.00001) but not in sex (p=0.6565). Head diameter: Ce-Ce with 19 of 28mm, 9 of 32 and 7 of 36mm; Me-PE with 63 of 28mm, 1 of 32 and 1 of 36. Follow-up averaged 10.5+/−3.1 years (1–15) in ceramic and 9.8+/−3.8 years (2–15) in XLPE group. Pearson, Fisher, Kolmogorov-Smirnov, Student, Mann-Whitney, calculated with the informatic tools Microsoft Excel 2007 and . https://www.socscistatistics.com/tests/. . Complications in ceramic joints: 2 late infections (Fisher exact test=0.6101) (1 DAIR, 1 one-stage exchange); 1 dislocation (Fisher exact test=0.2549) (closed reduction); 1 Vancouver C fracture (ORIF) (Fisher exact test=0.6548). Complications in Me-XLPE joints: 2 late infections (Fisher=0.6101) (1 DAIR, 1 two-stage exchange); 7 dislocations (Fisher=0.2549) (2 early, open reduction) (5 late: 3 closed reduction, 1 cup revision, 1 constrained cup); 4 Vancouver B fractures (Fisher=0.6548) (2 intraoperative, cerclages; 2 late, exchange). Final follow-up: Harris Hip Score averaged 93.2+/−13.7 (23–100) in ceramic and 94.3+/−8.7 (65–100) in XLPE joints (p=0.64552). Wear: 0.06+/−0.38mm (0–1.5) in ceramic and 0.16+/−0.5mm (0–2) in Me-PE THAs (p=0.30302). Osteolysis in Charnley-De Lee zones: 8 zones (6 patients) (17%) in ceramic cups, 25 zones (15 patients) (23%) in XLPE cups (p=0.980127). Survivorship without any surgery or closed reduction after 15 years: 91.0% in ceramic joints, 83.8% in Me-XLPE joints. Survivorship without component exchange after 15 years: 93.9% in ceramic joints, 93.6% in Me-XLPE joints. At least after 10 years follow-up of Furlong-HAP Active, metal-XLPE and ceramic-ceramic joints present no significant differences in complications, clinical score, wear, acetabular osteolysis, or survivorship without component exchange. On the contrary, survivorship without any surgery or closed reduction is different because of the high rate of dislocation in 28mm metal-poly joints


Bone & Joint Open
Vol. 4, Issue 1 | Pages 3 - 12
4 Jan 2023
Hardwick-Morris M Twiggs J Miles B Al-Dirini RMA Taylor M Balakumar J Walter WL

Aims

Iliopsoas impingement occurs in 4% to 30% of patients after undergoing total hip arthroplasty (THA). Despite a relatively high incidence, there are few attempts at modelling impingement between the iliopsoas and acetabular component, and no attempts at modelling this in a representative cohort of subjects. The purpose of this study was to develop a novel computational model for quantifying the impingement between the iliopsoas and acetabular component and validate its utility in a case-controlled investigation.

Methods

This was a retrospective cohort study of patients who underwent THA surgery that included 23 symptomatic patients diagnosed with iliopsoas tendonitis, and 23 patients not diagnosed with iliopsoas tendonitis. All patients received postoperative CT imaging, postoperative standing radiography, and had minimum six months’ follow-up. 3D models of each patient’s prosthetic and bony anatomy were generated, landmarked, and simulated in a novel iliopsoas impingement detection model in supine and standing pelvic positions. Logistic regression models were implemented to determine if the probability of pain could be significantly predicted. Receiver operating characteristic curves were generated to determine the model’s sensitivity, specificity, and area under the curve (AUC).


The Bone & Joint Journal
Vol. 106-B, Issue 4 | Pages 352 - 358
1 Apr 2024
Wilson JM Trousdale RT Bedard NA Lewallen DG Berry DJ Abdel MP

Aims

Dislocation remains a leading cause of failure following revision total hip arthroplasty (THA). While dual-mobility (DM) bearings have been shown to mitigate this risk, options are limited when retaining or implanting an uncemented shell without modular DM options. In these circumstances, a monoblock DM cup, designed for cementing, can be cemented into an uncemented acetabular shell. The goal of this study was to describe the implant survival, complications, and radiological outcomes of this construct.

Methods

We identified 64 patients (65 hips) who had a single-design cemented DM cup cemented into an uncemented acetabular shell during revision THA between 2018 and 2020 at our institution. Cups were cemented into either uncemented cups designed for liner cementing (n = 48; 74%) or retained (n = 17; 26%) acetabular components. Median outer head diameter was 42 mm. Mean age was 69 years (SD 11), mean BMI was 32 kg/m2 (SD 8), and 52% (n = 34) were female. Survival was assessed using Kaplan-Meier methods. Mean follow-up was two years (SD 0.97).


Bone & Joint Open
Vol. 4, Issue 8 | Pages 628 - 635
22 Aug 2023
Hedlundh U Karlsson J Sernert N Haag L Movin T Papadogiannakis N Kartus J

Aims

A revision for periprosthetic joint infection (PJI) in total hip arthroplasty (THA) has a major effect on the patient’s quality of life, including walking capacity. The objective of this case control study was to investigate the histological and ultrastructural changes to the gluteus medius tendon (GMED) in patients revised due to a PJI, and to compare it with revision THAs without infection performed using the same lateral approach.

Methods

A group of eight patients revised due to a PJI with a previous lateral approach was compared with a group of 21 revised THAs without infection, performed using the same approach. The primary variables of the study were the fibril diameter, as seen in transmission electron microscopy (TEM), and the total degeneration score (TDS), as seen under the light microscope. An analysis of bacteriology, classification of infection, and antibiotic treatment was also performed.


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_11 | Pages 33 - 33
1 Aug 2018
Waddell J Atrey A Wolfstadt J Khoshbin A Ward S
Full Access

A randomized trial was designed to compare the outcome of ceramic-on-ceramic with ceramic on conventional polyethylene. These patients have been followed for 15 years. 58 hips in 57 patients under 60 years of age were randomized into one of two groups. Patients were blinded to the type of hip they received. Both groups of patients were treated routinely with prophylactic peri-operative antibiotics and low molecular weight Heparin. All patients were seen at six weeks, three months and annually after surgery. Clinical and radiologic assessment was carried out at each visit. Fifty-eight hips were available for analysis, 28 in the CoP group and 29 patients in the CoC group. Mean age of both groups was less than 45 years. There were seven revisions (16%) among the 58 patients enrolled in the study. In the CoP group four patients underwent revision with head and liner exchange for eccentric polyethylene wear 16 years post-implantation. In the CoC group one patient had a cup revision at 15 years for acute aseptic instability of the acetabulum; two additional patients in the CoC group had femoral head exchange, one for fracture and one for trunnion corrosion. Both occurred 14 years after the index surgery. Functional outcome scores showed no difference between the two groups at 15 years. Radiographically there was a statistically difference in wear between the two groups. This study demonstrates that both ceramic-on-ceramic and ceramic-on-polyethylene produce satisfactory functional results with low revision rates in young patients


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_1 | Pages 49 - 49
1 Jan 2018
Garcia-Cimbrelo E Garcia-Rey E Sedel L
Full Access

Different pathologies, deformities, bone defects, previous surgeries and polyethylene wear limit the survival of total hip arthroplasty (THA) in young patients. We compare preoperative status and outcome in 171 young and very young patients (207 hips) who underwent a ceramic-on-ceramic THA. Sixty-three (77 hips) were less than 30 years old (group 1) and 108 (130) were between 30 and 40 years old. Mean follow-up was 11.3 years. Two-way ANOVA with repeated measures were used to analyse clinical and radiological changes. Juvenile rheumatoid arthritis (JRA) was the most frequent diagnosis in group 1 and avascular necrosis in group 2. Charnley class type C, low activivity, previous surgery and osteoporotic bone were more frequent in group 1 patients. There were 2 cup revisions for aseptic loosening in group 1 and 4 in group 2. Survivorship analysis at 15 years was 96.7% (95% IC 92.2 a 100) for group 1 and 96.1% (95% IC 92.2 to 100) for group 2 (p=0.749). Despite the worse preoperative status in group 1 patients, clinical outcome was similar in both groups. Severe dysplasia had the worst clinical result and avascular necrosis the best. Patients with Charnley class C and JRA showed the most improvement. Radiographic reconstruction of the abduction angle was worse in group 1 (p=0.02). No osteolysis or complications derived from ceramic use were found. We conclude that despite the worse preoperative status in group 1 patients, clinical and radiographic results were good in both groups of patients who received a ceramic-on-ceramic THA


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 5 | Pages 591 - 594
1 May 2007
Lie SA Hallan G Furnes O Havelin LI Engesæter LB

We analysed the results of different strategies in the revision of primary uncemented acetabular components reported to the Norwegian Arthroplasty Register. The aim was to compare the risk of further acetabular revision after isolated liner exchange and complete component revision. The results of exchanging well-fixed components were also compared with those of exchanging loose acetabular components. The period studied was between September 1987 and April 2005. The following groups were compared: group 1, exchange of liner only in 318 hips; group 2, exchange of well-fixed components in 398; and group 3, exchange of loose components in 933. We found that the risk of a further cup revision was lower after revision of well-fixed components (relative risk from a Cox model (RR) = 0.56, 95% confidence interval 0.37% to 0.87%) and loose components (RR = 0.56, 95% confidence interval 0.39% to 0.80%), compared with exchange of the liner in isolation. The most frequent reason for a further acetabular revision was dislocation, accounting for 61 (28%) of the re-revisions. Other reasons for further revision included pain in 27 (12%), loosening in 24 (11%) and infection in 20 (9%). Re-revisions because of pain were less frequent when complete component (fixed or loose) revision was undertaken compared with isolated exchange of the liner (RR = 0.20 (95% confidence interval 0.06% to 0.65%) and RR = 0.10 (95% confidence interval 0.03% to 0.30%), respectively). The risk of further acetabular revision for infection, however, did not differ between the groups. In this study, exchange of the liner only had a higher risk of further cup revision than revision of the complete acetabular component. Our results suggest that the threshold for revising well-fixed components in the case of liner wear and osteolysis should be lowered


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_12 | Pages 31 - 31
1 Jun 2017
Swanton E Hubble M
Full Access

Although cement in cement acetabular revision is a recognised option in the presence of a well-fixed cement mantle, partial cement mantle retention is not normally recommended or practiced. However, when revising a cemented acetabular cup it is not infrequent to be faced with loose superolateral cement but well-fixed medial cement. Removal of the well-fixed cement can be time consuming and destructive. An alternative would be to retain this cement and incorporate it into the reconstruction. This study assesses the practice and results of partial cement mantle retention (PCR) at acetabular revision. We retrospectively identified a cohort of 28 hips in 26 patients using the PCR technique from 1. st. January 2000 to 1. st. January 2013. This represented 3.3% of cup revisions where a cemented cup was used. The area of cement loss was reconstructed in one of three ways: re-cementing into drill holes (6 cases); impaction grafting of the defect (8 cases); or use of a trabecular metal wedge (14 cases). 24 hips had a minimum 2-year follow up (mean 6 years). There were no subsequent revisions for aseptic loosening. One acetabulum was later revised for dislocation and X-rays were lost in one patient leaving 22 patients with x-ray available and retained implants. Two of these cases showed progression of lucent lines, which were not clinically significant. Retaining well-fixed medial cement during socket revision appears to be a reasonable reconstruction option in carefully selected cases


The Bone & Joint Journal
Vol. 103-B, Issue 7 Supple B | Pages 66 - 72
1 Jul 2021
Hernandez NM Hinton ZW Wu CJ Lachiewicz PF Ryan SP Wellman SS

Aims

Modular dual mobility (MDM) acetabular components are often used with the aim of reducing the risk of dislocation in revision total hip arthroplasty (THA). There is, however, little information in the literature about its use in this context. The aim of this study, therefore, was to evaluate the outcomes in a cohort of patients in whom MDM components were used at revision THA, with a mean follow-up of more than five years.

Methods

Using the database of a single academic centre, 126 revision THAs in 117 patients using a single design of an MDM acetabular component were retrospectively reviewed. A total of 94 revision THAs in 88 patients with a mean follow-up of 5.5 years were included in the study. Survivorship was analyzed with the endpoints of dislocation, reoperation for dislocation, acetabular revision for aseptic loosening, and acetabular revision for any reason. The secondary endpoints were surgical complications and the radiological outcome.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_11 | Pages 26 - 26
1 Jun 2016
Abbas G Mullins M Dodd M Woodnutt D
Full Access

Press-fit fixation of uncemented acetabular components is increasingly being used for total hip replacement (THR) surgery. This study was aimed to analyse the survival of an established, un-cemented flexible metal backed cup with non-highly cross-linked polyethylene in primary and simple revision THR. We assessed the outcome of 1703 consecutive cementless elastic acetabular cups (Atlas, FH France) with non-highly cross-linked polyethylene (GUR1030) in total hip replacement surgery. There were 1582 patients (513 males and 1079 females) with mean age of 74 years (36–97 years). Seventeen senior operating surgeons accounted for 88.5% of cases from a single arthroplasty unit. Survival analysis was calculated using the Kaplan Meier Estimator. At 184 months post surgery the survivorship was 92.4% (95% CI 88.3–94.7) with cup revision for any cause as an endpoint. Three patients died within first month of surgery and 268 patients (17.13%) died due to unrelated causes. Overall, 59 patients had revisions (3.5%), Thirty eight patients (2.3%) were due to acetabular causes such as: aseptic loosening in 6 patients (0.35%); hip instability in 13 patients (0.76%); and deep infection in 11 patients (0.64%). We believe the cementless elastic acetabular cup on in total hip replacement is tolerant of technique and patient variation and continues to give excellent long-term results and its continued widespread use can be recommended