Purpose. We aimed to investigate whether the anterior superior iliac spine could provide consistent rotational landmark of the
Introduction. Malrotation of the
Purpose. To achieve 3D kinematic analysis of total knee arthroplasty (TKA), 2D/3D registration techniques, which use X-ray fluoroscopic images and computer aided design model of the knee implants, have been applied to clinical cases. However, most conventional methods have needed time-consuming and labor-intensive manual operations in some process. In particular, for the 3D pose estimation of
Objectives. All Polyethylene
Background. Total knee prostheses are continually being redesigned to improve performance, longevity and closer mimic kinematics of the native knee. Despite continued improvements, all knee implants even those with proven design features, have failures. We identified a cohort of patients with isolated
Introduction.
[Introduction]. One of the modern design total knee arthroplasty (TKA) system, the NexGen Legacy posterior-stabilized (LPS) Flex prosthesis, has been in use at our hospital since 2001. Between 2006 and 2011, NexGen LPS-Flex primary TKA were mainly performed in combination with a cemented short-keeled minimally invasive version tibial tray (MIS tibial component) instead of the traditional NexGen stemmed tibial tray. We observed some cases required early revision of isolated
Purpose. Medial tibial condylar fractures (MTCFs) are rare but a serious complication after unicompartmental knee arthroplasty (UKA). The reasons for MTCFs was thought to be associated with the surgical procedures that are the halls for the guide pins, extended cut of the posterior tibial cortex, an incorrect positioning of the tibial keel groove, and an excessive force application when placing the
Introduction. Stiffness postTotal Knee Replacement (TKR) is a common, complex and multifactorial problem. Many reports claim that component mal-rotation plays an important role in this problem. Internal mal-rotation of the
It is very important for implanting
Introduction. Stiffness post Total Knee Replacement (TKR) is a common, complex and multifactorial problem. Many reports claim that component mal-rotation plays an important role in this problem. Internal mal-rotation of the
Background. Several studies have reported that
There are basically 4 ways advocated to determine the proper femoral component rotation during TKA: (1) The Trans-epicondylar Axis, (2) Perpendicular to the “Whiteside Line,” (3) Three to five degrees of external rotation off the posterior condyles, and (4) Rotation of the component to a point where there is a balanced symmetric flexion gap. This last method is the most logical and functionally, the most appropriate. Of interest is the fact that the other 3 methods often yield flexion gap symmetry, but the surgeon should not be wed to any one of these individual methods at the expense of an unbalanced knee in flexion. In correcting a varus knee, the knee is balanced first in extension by the appropriate medial release and then balanced in flexion by the appropriate rotation of the femoral component. In correcting a valgus knee, the knee can be balanced first in flexion by the femoral component rotation since balancing in extension almost never involves release of the lateral collateral ligament (LCL) but rather release of the lateral retinaculum. If a rare LCL release is anticipated for extension balancing, then it would be performed prior to determining the femoral rotation since the release may open up the lateral flexion gap to a point where even more femoral component rotation is needed to close down that lateral gap. It is important to know and accept the fact that some knees will require internal rotation of the femoral component to yield flexion gap symmetry. The classic example of this is a knee that has previously undergone a valgus tibial osteotomy that has led to a valgus tibial joint line. In such a case, if any of the first 3 methods described above is utilised for femoral component rotation, it will lead to a knee that is very unbalanced in flexion being much tighter laterally than medially. A LCL release to open the lateral gap will be needed, increasing the complexity of the case. My experience has shown that intentional internal rotation of the femoral component when required is well-tolerated and rarely causes problems with patellar tracking. It is also of interest to note that mathematical calculations reveal that internally rotating a femoral component as much as 4 degrees will displace the trochlear groove no more that 2–3 mm (depending on the FC size), an amount easily compensated for by undersizing the patellar component and shifting it medially those few mm. There are basically 3 ways to determine the proper
Rotational malalignment in total knee arthroplasty (TKA) may lead to several complications. Transepicondylar axis has been accepted for a reference of femoral rotation. In contrast, standard reference of tibial rotation remains controversial. Currently, two techniques are widely used, the anatomical landmarks technique and the range-of-movement (ROM) technique. Fifty-one patients underwent posterior-stabilized TKA with center-post self-align ROM technique for
The anterior curve of the tibial plateau cortex represents a realiable and reproducible landmark which may help aligning the
Background. Although early TKA designs were symmetrical, during the past two decades TKA have been designed to include asymmetry, pertaining to either the trochlear groove, femoral condylar shapes or the
INTRODUCTION. Cemented total knee arthroplasty (TKA) is a widely accepted treatment for end-stage knee osteoarthritis. During this procedure, the surgeon targets proper alignment of the leg and balanced flexion/extension gaps. However, the cement layer may impact the placement of the component, leading to changes in the mechanical alignment and gap size. The goal of the study was to assess the impact of cement layer on the tibial mechanical alignment and joint gap during cemented TKA. MATERIAL. Computer-assisted TKAs (ExactechGPS®, Blue-Ortho, Grenoble, FR) were performed by two fellowship trained orthorpaedic surgeons on five fresh-frozen non-arthritic pelvis-to-ankle cadaver legs. All the surgeries used a cemented cruciate retaining system (Optetrak Logic CR, Exactech, Gainesville, FL). After the bony resection, the proximal tibial resection plane was acquired by manually pressing an instrumented checker onto the resected tibial surface (resection plane). Once the prosthesis was implanted through standard cementing techniques, the top surface of the implanted
Restoration of natural range and pattern of motion is the primary goal of joint replacement. In total ankle replacement, proper implant positioning is a major requirement to achieve good clinical results and to prevent instability, aseptic loosening, meniscal bearing premature wear and dislocation at the replaced ankle. The current operative techniques support limitedly the surgeon in achieving a best possible prosthetic component alignment and in assessing proper restoration of ligament natural tensioning, which could be well aided by computer-assisted surgical systems. Therefore the outcome of this replacement is, at present, mainly associated to surgeon's experience and visual inspection. In some of the current ankle prosthetic designs,
Introduction. The precise indications for