Advertisement for orthosearch.org.uk
Results 1 - 20 of 766
Results per page:
Bone & Joint Open
Vol. 5, Issue 10 | Pages 858 - 867
11 Oct 2024
Yamate S Hamai S Konishi T Nakao Y Kawahara S Hara D Motomura G Nakashima Y

Aims

The aim of this study was to evaluate the suitability of the tapered cone stem in total hip arthroplasty (THA) in patients with excessive femoral anteversion and after femoral osteotomy.

Methods

We included patients who underwent THA using Wagner Cone due to proximal femur anatomical abnormalities between August 2014 and January 2019 at a single institution. We investigated implant survival time using the endpoint of dislocation and revision, and compared the prevalence of prosthetic impingements between the Wagner Cone, a tapered cone stem, and the Taperloc, a tapered wedge stem, through simulation. We also collected Oxford Hip Score (OHS), visual analogue scale (VAS) satisfaction, and VAS pain by postal survey in August 2023 and explored variables associated with those scores.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_12 | Pages 60 - 60
23 Jun 2023
Yasunaga Y Ohshima S Shoji T Adachi N
Full Access

Satisfactory intermediate and long-term results of rotational acetabular osteotomy (RAO) for the treatment of early osteoarthritis secondary to developmental dysplasia of the hip have been reported. The purpose of this study is to examine the 30-year results of RAO.

Between 1987 and 1994, we treated 49 patients (55 hips) with RAO for diagnosis of pre- OA or early-stage OA. Of those patients, 35 patients (43 hips) were available at a minimum of 28 years. The follow-up rate was 78.2% and the mean follow-up was 30.5 years. The mean age at the time of surgery was 34 years. Clinical evaluation was performed with the Merle d'Aubigne and Postel rating scale, and radiographic analyses included measurements of the center-edge angle, acetabular roof angle, and head lateralization index on preoperative, postoperative AP radiographs of the pelvis. Postoperative joint congruency was classified into four grades. The radiographic evidence of progression of OA was defined as the minimum joint space less than 2.5mm.

The mean preoperative clinical score was 14.0, which improved to a mean of 15.3 at the time of the latest follow-up. The mean center-edge angle improved from 0.6° preoperatively to 34° postoperatively, the mean acetabular roof angle improved from 28.4°preoperatively to 1.0°postoperatively, the mean head lateralization index improved from 0.642 preoperatively to 0.59 postoperatively. Postoperative joint congruency was excellent in 11 hips, good in 29 hips, and fair in 3 hips. Nineteen patients (20 hips) had radiographic OA progression, and 10 patients (11 hips) were converted to THA. Kaplan-Meier survivorship analysis, with radiographic OA progression as the end point, predicted survival of 75.6% at 20 years and 48.8% at 30 years, and with THA conversion as the end point, 90.2% at 20 years and 71.2% at 30 years.

The RAO is an effective surgical procedure for symptomatic dysplastic hips of pre- and early-stage OA and could change the natural history of the dysplastic hip.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_12 | Pages 67 - 67
23 Jun 2023
Yamamoto T Fujita J
Full Access

Injury of the lateral femoral cutaneous nerve (LFCN) is one of the known complications after periacetabular osteotomy (PAO) using anterior approach. We previously reported that the incidence of LFCN injury was 48% at 1 year after PAO. However, there was no study examining the sequential changes of LFCN injury status. In this study, we performed a prospective over 3-year follow-up study as to the incidence of LFCN injury as well as its clinical outcomes. This study included 40 consecutive hips in 40 patients (3 males and 37 females) who underwent PAO from May 2016 to July 2018. The mean age at surgery was 36.7 years (17 to 60). The mean observation period was 47.3 months (36 to 69). The incidence and severity of LFCN injury was evaluated, while clinical scores, including the Harris Hip Score (HHS), Short-Form 36 Health Survey (SF-36), and Japanese Orthopaedic Association Hip Disease Evaluation Questionnaire (JHEQ), were also investigated. At 3 years after PAO, LFCN injury was observed in 13 of 40 (33%) patients, in which 7 patients who had a symptom at 1 year have completely recovered. There was no significant difference in the HHS and SF-36 between patients with and without LFCN injury at 3 years. Regarding the JHEQ, a significant difference was recognized in the patient satisfaction and mental score between patients with and without LFCN injury, but there were no significant differences in the other clinical scores. The incidence of LFCN injury gradually decreased to 33% at 3 years after CPO. LFCN injury did not influence the clinician-reported outcome, while it had a negative impact on patient satisfaction and mental score based on the patient-reported outcome


The Paprosky acetabular bone defect classification system and related algorithms for acetabular reconstruction cannot properly guide cementless acetabular reconstruction in the presence of porous metal augments.

We aimed to introduce a rim, points, and column (RPC)-oriented cementless acetabular reconstruction algorithm and its clinical and radiographic outcomes.

A total of 123 patients (128 hips) were enrolled. A minimum 5-year radiographic follow-up was available for 96 (75.8%) hips. The mean clinical and radiographic follow-up durations were 6.8±0.9 (range: 5.2–9.2) and 6.3±1.9 (range: 5.0–9.2) years, respectively.

Harris hip score (HHS) improved significantly from 35.39±9.91 preoperatively to 85.98±12.81 postoperatively (P<0.001). Among the fixation modes, 42 (32.8%) hips were reconstructed with rim fixation, 42 (32.8%) with three-point fixation without point reconstruction, 40 (31.3%) with three-point fixation combined with point reconstruction, and 4 (3.1%) with three-point fixation combined with pelvic distraction. Complementary medial wall reconstruction was performed in 20 (15.6%) patients. All acetabular components were radiographically stable. Nine-year cumulative Kaplan–Meier survival rates for 123 patients with the endpoint defined as periprosthetic joint infection, any reoperation, and dissatisfaction were 96.91% (confidence interval [CI]: 86.26%, 99.34%), 97.66% (CI: 92.91%, 99.24%), and 96.06% (CI: 86.4%, 98.89%), respectively.

Cup stability in cementless acetabular reconstruction depends on rim or three-point fixation. The continuity of the anterior and posterior columns determines whether the points provide adequate stability to the cup. Medial wall reconstruction is an important complementary fixation method for rim or three-point fixation. The patients who underwent cementless acetabular reconstruction guided by the RPC decision-making algorithm demonstrated satisfactory mid-term clinical function, satisfaction levels, radiographic results, and complication rates.


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_16 | Pages 60 - 60
19 Aug 2024
Lau LCM Cheung MH Ng FY Fu H Chan PK Chiu P
Full Access

In total hip arthroplasty (THA), cementless cup without screw holes has the putative benefits of maximizing host bone contact and reducing osteolysis by eliminating channels to backside wear particles. However, supplemental trans-acetabular screws cannot be used.

74 hips in 60 patients receiving same model of cementless cup without screw holes (Depuy Duraloc 100 HA cup) from 6/1999 to 3/2003 were prospectively followed up. All patients were allowed to have immediate full weight bearing. Age at THA was 53 ± 13 (range 24–74) years. Osteonecrosis was the leading hip disease (45% of hips). Survivorship was assessed using revision of the cup as the end point. Radiological parameters, including lateral opening angle, vertical and horizontal migration distances of the cups were measured. Paired t-test was used to compare between the measurements in early postoperative period and at final follow up.

51 hips were assessed at minimum 20 years follow-up. The mean follow-up was 22.6 (range 21 – 25) years. All the cups were well fixed. There were two cup revisions. Conventional polyethylene (PE) was used in both hips; osteolysis occurred 17 and 18 years later. Both cups were well fixed but were revised, one due to cup mal-positioning, one due to need in upsizing the articulation. 14 other hips were revised but these cups were well fixed and not revised; 9 loosened stems (most were cemented Elite plus stems), 5 PE wear and osteolysis (all were conventional PE). At 20 years, the survivorship of cups was 96.1%. Changes in lateral opening angle, vertical and horizontal migration distances were 0.44±1.59°, 0.01±1.52mm and -0.32±1.47mm respectively, without statistical significance.

This study provided evidence of excellent long-term survivorship of cementless cup without screw holes. Immediate postoperative weight-bearing also did not lead to cup migration in the long-term.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_8 | Pages 117 - 117
11 Apr 2023
Roser M Izatt M Labrom R Askin G Little P
Full Access

Anterior vertebral body tethering (AVBT) is a growth modulating procedure used to manage idiopathic scoliosis by applying a flexible tether to the convex surface of the spine in skeletally immature patients. The purpose of this study is to determine the preliminary clinical outcomes for an adolescent patient cohort.

18 patients with scoliosis were selected using a narrow selection criteria to undergo AVBT. Of this cohort, 11 had reached a minimum follow up of 2 years, 4 had reached 18 months, and 3 had reached 6 months. These patients all demonstrated a primary thoracic deformity that was too severe for bracing, were skeletally immature, and were analysed in this preliminary study of coronal plane deformity correction.

Using open-source image analysis software (ImageJ, NIH) PA radiographs taken pre-operatively and at regular follow-up visits post-operatively were used to measure the coronal plane deformity of the major and compensatory curves.

Pre-operatively, the mean age was 12.0 years (S.D. 10.7 – 13.3), mean Sanders score 2.6 (S.D. 1.8-3.4), all Risser 0 and pre-menarchal, with mean main thoracic Cobb angle of 52° (S.D. 44.2-59.8°). Post-operatively the mean angle decreased to 26.4° (S.D. 18.4-32°) at 1 week, 30.4° (S.D. 21.3-39.6°) at 2 months, 25.7° (S.D. 18.7-32.8°) at 6 months, 27.9° (S.D. 16.2-39.6°) at 12 months, and 36.8° (S.D. 22.6– 51.0°) at 18 months and 38.2° (S.D. 27.6-48.7°) at 2 years. The change in curve at 2 years post-operative was statistically significant (P=0.004).

There were 4 tether breakages identified that did not require return to theatre as yet, one patient underwent a posterior spinal instrumented fusion due to curve progression.

AVBT is a promising new growth modulation technique for skeletally immature patients with progressive idiopathic scoliosis. This study has demonstrated a reduction in scoliosis severity.


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_4 | Pages 146 - 146
1 Apr 2019
Sugita T Aizawa T Miyatake N Miyamoto S Sasaki A Maeda I Honma T Kamimura M Takahashi A
Full Access

Introduction. Patient self-reported outcome scales have recently been used to evaluate total knee arthroplasty (TKA) outcomes. Many follow-up studies have been conducted on patients undergoing TKA; however, they have mostly reported outcomes after unilateral TKA. We believe that a longitudinal study after bilateral TKA will be more useful in evaluating the quality of life (QOL) of such patients. Objectives. The objective of this study was to longitudinally evaluate QOL using the Japanese Knee Osteoarthritis Measure (JKOM). Objective outcomes were assessed using the Knee Society Score (KSS) and the Timed Up and Go test (TUG) for more than 5 years after bilateral TKA. Furthermore, QOL and objective outcomes were compared between younger (age ≤ 80 years at the final follow-up point) and older (age > 80 years) age groups. Methods. In total, 109 patients underwent two-staged bilateral TKAs for varus knee osteoarthritis at our clinic between October 2006 and March 2013. Of these patients, 78 were evaluated preoperatively (Pre) and at 1, 3 and 5 years or more (average, 6.7 years; range, 5–10 years) after bilateral TKAs using JKOM, KSS and TUG. The average patient age at the time of the first and the contralateral TKAs was 73.3 (range, 61–85) years and 74.0 (range, 62–85) years, respectively. The average patient age at the final follow-up point among younger (36 patients) and older (42 patients) age groups was 75.8 (range, 67–80) years and 84.7 (range: 81–92) years, respectively. The outcomes at each evaluation point were compared using Steel–Dwass test. A comparison of the JKOM scores and objective outcomes between the younger and older age groups was performed using Mann–Whitney U-test. P values < 0.05 were considered significant. Results. A significant improvement in the JKOM score was observed between ‘Pre’ and ‘1 year after bilateral TKA’; the improvement was maintained until the final follow-up point. All four subscales in JKOM showed the same improvement as JKOM itself. Furthermore, significant improvements in the total KSS, knee and function scores were observed between ‘Pre’ and ‘1 year after bilateral TKA’; the improvement was maintained until the final follow-up point. A significant improvement in the TUG scores was observed between ‘Pre’ and ‘1 year after bilateral TKA’; although the improvement was maintained for 3 years, there was a small but significant deterioration at the final follow-up point. Although the average age difference between the two groups was 8.9 years, no significant differences were found in the JKOM and objective outcome scores between the younger and older age groups. Conclusions. This is the first longitudinal mid-term follow-up study to evaluate QOL after bilateral TKAs. The JKOM and objective outcome scores reached a plateau 1 year after bilateral TKA, and the improvement was maintained for an average of 6.7 years; however, TUG scores showed a small deterioration at the final follow-up point. The improvement in the JKOM and objective outcome scores maintained by the older age group was equivalent to that by the younger one


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_13 | Pages 28 - 28
1 Dec 2022
Simon M
Full Access

In older patients (>75 years of age), with an intact rotator cuff, requiring a total shoulder replacement (TSR) there is, at present, uncertainty whether an anatomic TSR (aTSR) or a reverse TSR (rTSR) is best for the patient. This comparison study of same age patients aims to assess clinical and radiological outcomes of older patients (≥75 years) who received either an aTSR or a rTSA.

Consecutive patients with a minimum age of 75 years who received an aTSR (n=44) or rTSR (n=51) were prospectively studied. Pre- and postoperative clinical evaluations included the ASES score, Constant score, SPADI score, DASH score, range of motion (ROM) and pain and patient satisfaction for a follow-up of 2 years. Radiological assessment identified glenoid and humeral component osteolysis, including notching with a rTSR.

Postoperative improvement for ROM and all clinical assessment scores for both groups was found. There were significantly better patient reported outcome scores (PROMs) in the aTSR group compared with the rTSR patients (p<0.001). Both groups had only minor osteolysis on radiographs. No revisions were required in either group. The main complications were scapular stress fractures for the rTSR patients and acromioclavicular joint pain for both groups.

This study of older patients (>75 years) demonstrated that an aTSR for a judiciously selected patient with good rotator cuff muscles can lead to a better clinical outcome and less early complications than a rTSR.


The Bone & Joint Journal
Vol. 106-B, Issue 5 Supple B | Pages 25 - 31
1 May 2024
Yasunaga Y Oshima S Shoji T Adachi N Ochi M

Aims

The objective of this study was to present the outcomes of rotational acetabular osteotomy (RAO) over a 30-year period for osteoarthritis (OA) secondary to dysplasia of the hip in pre- or early-stage OA.

Methods

Between September 1987 and December 1994, we provided treatment to 47 patients (55 hips) with RAO for the management of pre- or early-stage OA due to developmental hip dysplasia. Of those, eight patients (11 hips) with pre-OA (follow-up rate 79%) and 27 patients (32 hips) with early-stage OA (follow-up rate 78%), totalling 35 patients (43 hips) (follow-up rate 78%), were available at a minimum of 28 years after surgery.


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_7 | Pages 18 - 18
1 Jul 2020
Schaeffer E Miller S Juricic M Mulpuri K Steinbok P Bone J
Full Access

Children with cerebral palsy (CP) have an increased risk of progressive hip displacement. While the cause of hip displacement remains unclear, spasticity and muscle imbalance around the hip are felt to be a major factor. There is strong evidence demonstrating that a selective dorsal rhizotomy (SDR) reduces spasticity. However, the impact of this decreased spasticity on hip displacement is unknown. Past studies, which are small and lack long-term follow-up, do not provide a clear indication of the effect of SDR on hip displacement. The purpose of this study was to determine the influence of SDR on hip displacement in children with CP a minimum of five years post-SDR. A retrospective chart review was completed. Participants were selected from a consecutive series of children who had an SDR before January 1, 2013 at one tertiary care facility to ensure a minimum five year follow-up. Pre-operative and minimum five year post-SDR AP pelvis radiographs were required for inclusion. Hip displacement was evaluated using change in MP between radiographs completed pre-SDR and minimum five years post-SDR, or until orthopaedic hip surgery. In total, 77 participants (45 males, 32 females) at GMFCS levels of I (1), II (11), III (22), IV (35) and V (8) were included in the review. Mean age at time of SDR was 5 years (2.8– 11.6yrs). Pre-SDR mean MP of the 154 hips was 29% (0–100%). Post-SDR, 67 (43.5%) hips in 35 children had soft tissue, reconstructive, or salvage hip procedures at an average of 4.9 years (0.5–13.8yrs) post-SDR and an average MP of 46% (11–100%). In addition, seven hips (5%) had a MP ≥ 40% (40–100%) at most recent radiographic review that averaged 11 years (5.6–18.6yrs). Overall, the total number of subjects with hip displacement measuring MP >40% or who had a surgical hip intervention, by GMFCS level, was: 0 (0%) at level I, 0 (0%) at level II, 20 (45%) at level III, 22 (59%) at level IV, and 5 (81%) at level V. The incidence of hip displacement in children with CP post-SDR did not substantially differ from the overall incidence reported in the literature when evaluated by GMFCS level. This study is the largest long-term follow-up study investigating the effect of hip displacement post-SDR. Results suggest that SDR does not impact hip displacement in CP, however, further prospective study will be required to strengthen the evidence in this regard


Highly cross-linked polyethylene (HXLPE) has decreased wear and revision rates in total hip replacement (THR) at a long-term. However, the effect of HXLPE manufacturing characteristics on femoral head penetration has not been clearly defined yet. We report this single-institution study to investigate the clinical and radiological results of different HXLPE liners in THR.

In this retrospective cohort analysis of our prospective database, we identified 904 THRs performed between 2000 and 2013. Seven different HXLPE liner types were assessed: remelted (3), annealed (2), sequentially annealed (1) and vitamin E-infused (1). The linear femoral head penetration rate was measured at six weeks, one year, and annually thereafter, using the Roman Software v1.70 package.

Thirty hips were revised for the following reasons: aseptic loosening (11), dislocation (12), periprosthetic femoral fracture (6), and infection (1). No hip was revised for wear or osteolysis. 741 THRs were evaluated for a mean follow-up of 15 years (range, 10 to 20). The mean total penetration 15 years after THR was 0.17 mm in the sequentially annealed, and 0.16 mm in the vitamin E-infused groups, whereas it was 0.26 mm in the melted 95 kGy, 0.27 mm in the melted 5 Mrad and 0.25 mm in the melted 100 kGy groups (p=0.001). From one to 15 years after surgery, the mean wear was 0.206 mm in cups with an acetabular inclination greater than 50º and 0.105 mm in those placed between 35º and 50º (p<0.001).

Although HXLPE characteristics can result in a different wear performance in patients undergoing THR at a mean follow-up of 15 years, the clinical results are excellent. The position of the acetabular component can influence on the femoral head penetration of modern HXLPEs. Nevertheless, these patients should continue to be monitored to detect future problems.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_3 | Pages 131 - 131
1 Feb 2017
Garcia-Rey E Cimbrelo EG Cruz-Pardos A
Full Access

Background and aim. A significant reduction in wear using Durasul highly cross-linked polyethylene (PE) versus Sulene polyethylene (sterilized with nitrogen) at 5 and 10 years have been reported previously. We ask if the improvement observed at the earlier follow-up continues at 15 years. Methods. Between 1999 and 2001, 90 hips underwent surgery using the same cementless cup and stem: 45 received Allofit cups with a Sulene-PE liner and 45 Allofit cups with a Durasul-PE liner, both associated with an Alloclassic stem (28 mm metallic femoral head). 66 hips of this prospective comparative study were available over a minimum follow-up of 15 years. Linear femoral head penetration was estimated digitally at 6 weeks, at 6 and 12 months and annually thereafter, using the Dorr method, given the nonspherical cup shape. All radiographs were evaluated by the same author, who was not involved in surgery. Results. 2 hips in the Sulene group showed proximal femoral osteolysis, one of these was revised for stem loosening at 12 years. There was no loosening of any other prosthetic component. Femoral head penetration in the one year postoperative radiographs was 0.23 mm (range, 0.08–0.23) for the Sulene group and 0.10 mm (0.04–0.11) for the Durasul group (p<0.001). The mean yearly linear femoral head penetration was 68.8 % lower for the Durasul group: 0.020+0.018 mm for the Durasul and 0.062+0.051 mm/year for the Sulene group (p<0.001). Mean linear femoral head penetration at 15 years was 64.5 % less in the Durasul group (0.394+0.27 mm) than in the Sulene group (1.108+0.78 mm)(p=0.001). Conclusions. There is a significant reduction in yearly linear femoral head penetration with the Durasul-PE. Confirmation that this reduction will result in less osteolysis requires continued follow-up studies


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_4 | Pages 10 - 10
1 Mar 2021
To K Khan W Marway P
Full Access

Companies manufacturing total knee arthroplasty (TKA) prostheses produce a variety of tibial and femoral components of different dimensions denoted by numbers or letters. Surgeons frequently implant components that are compatible but not of the same size on the femur and tibia. Recent studies suggest that equally sized femoral and tibial components produce better outcomes compared to size-mismatched components. In our study, we aim to explore the relationship between component size and outcome measured by oxford knee score at six weeks and one year following TKA.

A cohort of twenty-four patients who underwent TKA and had well-functioning prosthesis were studied. Thirteen (54%) had equally sized TKA components implanted, seventy-four patients (42%) had components that were mismatched by one size, and one (4%) had components that were mismatched by more than one size. The Oxford Knee Score (OKS) obtained preoperatively, at six weeks and one year postoperatively were retrieved from an electronic database. All data were analysed using R software.

A significant improvement in pre-operative and one-year postoperative OKS was observed. Patients who received one-size mismatched tibial and femoral components demonstrated a less pronounced improvement in OKS as compared with patients who received equally sized components.

When possible, it may be best to utilise equally sized prosthetic tibial and femoral components when performing total knee arthroplasty. Manufacturers may be able to produce better patient outcomes by including prostheses that are between sizes as part of their production line.


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_11 | Pages 7 - 7
1 Oct 2019
Catani F Ensini A Zambianchi F Illuminati A Matveitchouk N
Full Access

Introduction

Robotic technology has been applied to unicompartmental knee arthroplasty (UKA) in order to improve surgical precision in prosthetic component placement, restore knee anatomic surfaces, and provide a more physiologic ligament tensioning throughout the knee range of motion. Recent literature has demonstrated high reliability of robotic-arm assisted UKA in component placement and executing a soft-tissue tensioning plan, with excellent short-term survivorship. Few studies have investigated survivorship and patients' satisfaction at longer follow-ups. Therefore, the purpose of the present study was to determine the survivorship, clinical results and patients' satisfaction of robotic-arm assisted UKAs at a mid-term follow-up, with a minimum of 5 years of follow-up.

Methods

The present retrospective study includes 252 patients (260 knees) who underwent robotic-arm assisted fixed bearing metal backed UKAs at a single centre between April 2011 and July 2013. The mean age at surgery was 66.2 years (SD 8.6). Post-operatively, patients were administered the Forgotten Joint Score-12 (FJS) and asked about their satisfaction level after knee surgery (grade from 1 to 5). Post-operative complications were recorded. Failure mechanisms, revisions and reoperations were also assessed. Kaplan-Meier survival curves were calculated, considering reoperation for all causes and revision as the events of interest.


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 11 | Pages 1452 - 1456
1 Nov 2007
Roberts VI Esler CNA Harper WM

This is a 15-year follow-up observational study of 4390 patients with 4606 primary total knee replacements (TKRs) implanted in the Trent health region between 1990 and 1992. The operations were performed in 21 hospitals, including both district general and teaching hospitals, with 77 different surgeons as named consultant. The main objective was to analyse the survival of the patients and of the prostheses, and to evaluate what impact different variables have on survival. In addition, the 1480 patients (33.7%) (1556 TKRs) alive at 15 years following operation were sent a self-administered questionnaire which examined their level of satisfaction, of pain, and their quality of life at 15 years. Completed responses were received from 912 TKRs (58.6%). Three survival curves were constructed: a best-case scenario based on the patients entered into the life tables, another included failures not reported in the revision database, and a third worst-case scenario based on all patients lost to follow-up presumed to have had a failed primary TKR. In the best-case scenario survival at 15 years was 92.2%, and in the worst-case scenario was 81.1%. Survival was significantly increased in women and older patients (Mantel-Cox log-rank test, p < 0.005 and p < 0.001, respectively). Revision as a result of infection was required in 40 TKRs (18.8%) representing 0.87% of the original cohort. The limited information available from the questionnaire indicated that satisfaction was less frequent among men, patients with osteoarthritis and those who required revision (chi-squared test, p < 0.05, p < 0.05 and p < 0.0001, respectively). With regard to pain, older patients, females and patients who still had their primary replacement in place at 15 years, reported the least pain (chi-squared test for trends, p < 0.0005, p < 0.005 and p < 0.0001, respectively). The reported quality of life was not affected by any variable


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_10 | Pages 152 - 152
1 May 2016
Zhu M Chen J Chong H Yew A Foo L Chia S Lo N Yeo S
Full Access

Objective. Patient-specific instrumentation (PSI) is a novel technique in total knee arthroplasty (TKA) which potentially permits more accurate alignment of the components; however, there is no consensus in literature regarding the accuracy and reliability of PSI as many studies have shown controversial and inconsistent results of various PSI systems. A 24-month follow-up study was carried out to compare perioperative clinical outcomes, radiological limb alignment and component positioning, as well as functional outcomes following TKA between PSI and conventional instrumentation (CI). Methods. During September 2011 and August 2012, 90 consecutive patients were scheduled to undergo unilateral TKA with either PSI or CI. TruMatch® Personalised Solutions was used in this study, and a senior surgeon performed all operations. Patients were clinically assessed before, 6-month and 24-month after surgery. Results. There were 42 patients who underwent TKA with PSI and 48 patients with CI, with no preoperative demographic and clinical difference. There was significant improvement in maximal extension for both groups at both of the two follow-ups, compared to baseline. While the CI group maintained similar maximal flexion angle, PSI group had significant decrease in maximal flexion angle, at both follow-ups. Overall, there was no significant improvement in the range of motion for both groups over the 24-month period after surgery. At 6 and 24 months postoperatively, there were similarly significant improvements in the mean scores of Oxford Knee Score, Knee Society Score, and Physical Component Sscore of the SF-36 Health Survey for both groups. At 24 months postoperatively, no significant differences were detected between PSI and CI groups in all clinical and functional outcomes. Radiographic results showed that the lower limb mechanical alignment and coronal component positioning were satisfactory and similar between the two groups. There were no differences in operating time, haemoglobin loss, transfusion rate and length of hospitalisation between PSI and CI, perioperatively. Conclusion. In conclusion, CT-based PSI showed comparable clinical and functional outcomes at 24 months after TKA compared with CI. There were no significant differences between the two types of instruments in achieving alignment restoration, component positioning, and perioperative clinical outcomes in terms of operating time and blood loss


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_1 | Pages 149 - 149
1 Jan 2016
Garcia-Cimbrelo E
Full Access

Different bearing surfaces, including alumina-on-alumina have been used to avoid osteolysis.

We ask if the use of modern ceramics matched with metal-backed sockets improves clinical results avoiding aseptic loosening, osteolysis and late dislocations.

We prospectively analysed 315 Cerafit cups in two different generations: First generation implanted between 1999 and 2005 (124 cups) and second generation (191 cups) all implanted with a 5-year minimum follow-up, and associated with a Multicone-HAP stem using alumina-on-alumina bearings. Patients' mean age was 48.7+13.6 years.

There were three dislocations within the first postoperative month and one early recurrent dislocation requiring reoperation using a double mobility cup. There were four intraoperative fractures, two in rheumatoid juvenile arthritis cases solved with a cerclage, and one postoperative fracture solved using a femoral long-stem. No fractures were seen in the alumina components in this series. Also, there have been no infections. There were 4 patients reporting non-reproducible squeaking. Survivorship analysis for cup loosening for any cause was 93% for group 1 (11 cups) and 99.2% for group 2 (1 cup in a patient with severe developmental dysplasia). The cumulative probability of not having a revision of one or both components for any cause was 96.9% (CI 95%:9.47–99.1%), All unrevised cases showed good clinical and radiographic results at the end of follow-up. No stem loosening, osteolysis nor stress shielding were found in any case by the end of follow-up. Changes in linear femoral head penetration were not seen in any hip.

These data suggest that Cerafit alumina-on-alumina prostheses show excellent results after fiften years. Cup loosening was more frequent in the cups of first generation, but not currently. Continued follow-up will be required to determine if reduction in wear between the alumina-on alumina bearings results in less osteolysis and loosening.


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_11 | Pages 34 - 34
1 Aug 2018
García-Rey E García-Cimbrelo E Cordero-Ampuero J
Full Access

We assessed the clinical and radiological outcome of a single uncemented total hip replacement (THR) after twenty years, analysing polyethylene wear and osteolysis.

82 hips implanted between 1992 and 1995 were prospectively evaluated. Mean follow-up was 20.6 years (18–23). A hemispherical porous-coated cup matched to a proximally hydroxyapatite-coated anatomic stem. A 28mm PE liner, sterilised by gamma irradiation in air, was used in all hips. Radiological position, eventual loosening and osteolysis were recorded over time. Penetration of the head into the liner was measured by the Roentgen Monographic Analysis (ROMAN) Tool at 6 weeks, 6 months, one year and yearly thereafter.

Six cups were revised due to wear and four cups because of late dislocation. All stems showed osseointegration and all cups appeared radiographically well-fixed. Six unrevised hips showed osteolysis on the acetabular side and two hips on the proximal femur. Creep at one year was 0.30±0.23 mm. Mean total femoral head penetration was 1.23mm at ten years, 1.52mm at 15 years and 1.92mm at 23 years. Overall mean wear was 0.12±0.1 mm/year and 0.09±0.06 mm/year after the creep period. Mean wear was 0.08±0.06 mm/year in hips without osteolysis and 0.14±0.03 mm/year in hips revised or hips with osteolysis (p<0.001).

Although continued durable fixation can be observed with porous-coated cups and proximally hydroxyapatite-coated anatomic stems, true wear continues to increase at a constant level over time. PE wear remains as the main reason for osteolysis and revision surgery in uncemented THR after twenty years.


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_7 | Pages 6 - 6
1 May 2019
Scott C Clement N Yapp L MacDonald D Patton J Burnett R
Full Access

Anterior knee pain (AKP) is the commonest complication of total knee arthroplasty (TKA). This study aims to assess whether sagittal femoral component position is an independent predictor of AKP after cruciate retaining single radius TKA without primary patellofemoral resurfacing.

From a prospective cohort of 297 consecutive TKAs, 73 (25%) patients reported AKP and 89 (30%) reported no pain at 10 years. Patients were assessed pre-operatively and at 1, 5 and 10 years using the short form 12 and Oxford Knee Score (OKS). Variables assessed included demographic data, indication, reoperation, patella resurfacing, and radiographic criteria.

Patients with AKP (mean age 67.0 (38–82), 48 (66%) female) had mean Visual Analogue Scale (VAS) Pain scores of 34.3 (range 5–100). VAS scores were 0 in patients with no pain (mean age 66.5 (41–82), 60 (67%) female). Femoral component flexion (FCF), anterior femoral offset ratio, and medial proximal tibial angle all differed significantly between patients with AKP and no pain (p<0.001), p=0.007, p=0.009, respectively). All PROMs were worse in the AKP group at 10 years (p<0.05). OKSs were worse from 1 year (p<0.05). Multivariate analysis confirmed FCF and Insall ratio <0.8 as independent predictors of AKP (R2 = 0.263). Extension of ≥0.5° predicted AKP with 87% sensitivity.

AKP affects 25% of patients following single radius cruciate retaining TKA, resulting in inferior patient-reported outcome measures at 10 years. Sagittal plane positioning and alignment of the femoral component are important determinants of long-term AKP with femoral component extension being a major risk factor.


Orthopaedic Proceedings
Vol. 84-B, Issue SUPP_III | Pages 262 - 263
1 Nov 2002
Indelli P Dillingham M
Full Access

Objective: Bone-patellar tendon-bone (BPTB) and Achilles tendon allografts have been widely used in primary and revision ACL reconstructions showing good results comparable to those with autografts. The literature is sparce with regard to treatment and results of primary ACL reconstruction using Achilles tendon alone. The objective of this study was to present the clinical outcome of 50 consecutive primary ACL reconstructions with Achilles allograft utilizing interference screws fixation. Particular attention was dedicated to the incidence of tunnel widening and graft rejection phenomenon. Methods: Fifty consecutive patients had primary ACL reconstruction using fresh frozen Achilles tendon allografts from 1997 to 1998 at our institution. All grafts were sterilely harvested and none of them were subjected to secondary sterilization. All procedures were performed using interference screws fixation. A two-year minimum follow-up study was conducted in all of the patients: clinical and functional evaluation was performed according to the International Knee Documentation Committee (IKDC) by an independent examiner. All patients were evaluated using the KT-1000 arthrometer at 30 pounds of force: data was reported as an injured-to-uninjured difference. Lateral and 45° posteroanterior weightbearing radiographs were performed in each patient. The sclerotic margins of the tibial tunnel were measured at the widest dimension by a single observer and were compared with the initially drilled tunnel size. Results: According to the IKDC rating system, the overall outcome was normal or nearly normal in 96% of the patients. Forty-eight patients had a 30 pound side to side difference £ 5 mm. None of the patients had greater than a 10 mm difference. There was no evidence of graft rejection from an immune response or disease transmission. On the femoral side, all bone plugs appeared to be incorporated radiographically. The average allograft tibial tunnel enlargement at the widest level was 1.9 mm (0 to 5 mm) in the posteroanterior view and 1.7 mm (−0.2 to 5 mm) in the lateral view. Conclusion: Our results suggest that fresh frozen Achilles tendon allografts represent a good alternative in primary ACL reconstructions. No significant difference was seen in KT-1000 arthrometer measurements and clinical outcomes between patients with different tibial tunnel widening. We believe that fixation with interference screws could reduce the incidence of this undesirable phenomenon