We conducted a retrospective study to investigate the effect of
Introduction. The success of knee replacement surgery depends, in part, on restoration of the correct alignment of the leg with respect to the load-bearing vector passing from the hip to the ankle (the mechanical axis). Conventional thinking is that the correct angle of resection of the distal femur (Valgus Cut Angle, VCA) depends on femoral length or femoral offset, though
Aims. The impact of a diaphyseal femoral deformity on knee alignment varies according to its severity and localization. The aims of this study were to determine a method of assessing the impact of diaphyseal femoral deformities on knee alignment for the varus knee, and to evaluate the reliability and the reproducibility of this method in a large cohort of osteoarthritic patients. Methods. All patients who underwent a knee arthroplasty from 2019 to 2021 were included. Exclusion criteria were genu valgus, flexion contracture (> 5°), previous femoral osteotomy or fracture, total hip arthroplasty, and femoral rotational disorder. A total of 205 patients met the inclusion criteria. The mean age was 62.2 years (SD 8.4). The mean BMI was 33.1 kg/m. 2. (SD 5.5). The radiological measurements were performed twice by two independent reviewers, and included hip knee ankle (HKA) angle, mechanical medial distal femoral angle (mMDFA), anatomical medial distal femoral angle (aMDFA), femoral neck shaft angle (NSA),
Aims. The incidence of atypical femoral fractures (AFFs) continues to increase. However, there are currently few long-term studies on the complications of AFFs and factors affecting them. Therefore, we attempted to investigate the outcomes, complications, and risk factors for complication through mid-term follow-up of more than three years. Methods. From January 2003 to January 2016, 305 patients who underwent surgery for AFFs at six hospitals were enrolled. After exclusion, a total of 147 patients were included with a mean age of 71.6 years (48 to 89) and 146 of whom were female. We retrospectively evaluated medical records, and reviewed radiographs to investigate the fracture site, femur bowing angle, presence of delayed union or nonunion, contralateral AFFs, and peri-implant fracture. A statistical analysis was performed to identify the significance of associated factors. Results. The mean follow-up period was 70.2 months (36 to 191). There were 146 AFFs (99.3%) in female patients and the mean age was 71.6 years (48 to 89). The AFFs were located in the subtrochanter and shaft in 52 cases (35.4%) and 95 (64.6%), respectively. The preoperative mean anterior/lateral
Aims. The aims of this retrospective study were to determine the incidence of extra-articular deformities (EADs), and determine their effect on postoperative alignment in knees undergoing mobile-bearing, medial unicompartmental knee arthroplasty (UKA). Patients and Methods. Limb mechanical alignment (hip-knee-ankle angle), coronal bowing of the femoral shaft and proximal tibia vara or medial proximal tibial angle (MPTA) were measured on standing, full-length hip-to-ankle radiographs of 162 patients who underwent 200 mobile-bearing, medial UKAs. Results. Incidence of EAD was 7.5% for coronal
Summary sentence. The bowing of the femur defines a curvature plane to which the proximal and distal femoral anatomic landmarks have a predictable interrelationship. This plane can be a helpful adjunct for computer navigation to define the pre-operative, non-diseased anatomy of the femur and more particularly the rotational alignment of the femoral component in total knee arthroplasty (TKA). Background and aims. There is very limited knowledge with regards to the sagittal curvature -or bowing- of the femur. It was our aim (1) to determine the most accurate assessment technique to define the
Traditional instrumentation relies on rigid IM rods to determine the distal femoral resection which influences size and orientation of the femoral component. Anterior
The evaluation of the middle term behaviour of the Wagner-type stems in dysplastic femurs and the presentation of the technical and surgical differences with the implantation of a Wagner stem. Between 1997 and 2008 we implanted 64 Wagner stems in 58 patients. Average age at the time of implantation was 64 years. 52 patients was operated because of DDH, and 12 had had previous osteotomy. All patients were prospectively evaluated radiographically and clinically at annual intervals. Functional outcome was assessed with Harris Hip Score and Oxford Score. Mean follow-up of these series was 4 years (11-1)One stem was revised because of fracture of the lesser trochander and two more patients were re-operated for open reduction. With the re-operation as end-point and 95% Confidence Interval survivorship rate was 98, 5%. There were no progressive radiolucent lines. Stem migration was at an average 2mm (1–6) during the first two years and remained stable thereafter. There was no deep infection in these series. After the second year a dense zone is evident in all Gruen zones at the implant –bone interface with a width of 2–3 mm. Dysplasia of the proximal femur may pose significant technical problems during THA due to the distortion of the geometry and the narrowing of the femoral canal. The sort, conical Wagner type stems can offer a very good alternative is such patients. They allow control of the anteversion and they are able get a good press-fit despite the metaphyseal/diaphyseal mismatch and the
Aim: The evaluation of the middle term behaviour of the Wagner-type stems in dysplastic femurs and the presentation of the technical and surgical differences with the implantation of a Wagner stem. Materials and Methods: Between 1997 and 2008 we implanted 64 Wagner stems in 58 patients. Average age at the time of implantation was 64 years. 52 patients was operated because of DDH, and 12 had had previous osteotomy. All patients were prospectively evaluated radiographically and clinically at annual intervals. Functional outcome was assessed with Harris Hip Score and Oxford Score. Results: Mean follow-up of these series was 4 years (11-1)One stem was revised because of fracture of the lesser trochander and two more patients were re-operated for open reduction. With the re-operation as end-point and 95% Confidence Interval survivorship rate was 98, 5%. There were no progressive radiolucent lines. Stem migration was at an average 2mm (1–6) during the first two years and remained stable thereafter. There was no deep infection in these series. After the second year a dense zone is evident in all Gruen zones at the implant –bone interface with a width of 2–3 mm. Discussion: Dysplasia of the proximal femur may pose significant technical problems during THA due to the distortion of the geometry and the narrowing of the femoral canal. The sort, conical Wagner type stems can offer a very good alternative is such patients. They allow control of the anteversion and they are able get a good press-fit despite the metaphyseal/diaphyseal mismatch and the
Despite the well-documented improvement in coronal alignment achieved by computer assisted navigation, varying results have been reported for sagittal alignment. Current navigation systems rely on a sagittal femoral mechanical axis identified by the navigation system, but little information is available on the relationship between the sagittal mechanical axis and anatomical axes for intra-operative or postoperative radiographic assessments. We asked whether deviations exist between sagittal femoral mechanical axis and anatomical axes and attempted to identify predictors of the deviations found. In 100 consecutive patients (200 knees) undergoing TKA, angles between two anatomical axes (the anterior cortical line and mid-medullary line) and two sagittal mechanical axes identified by current navigation systems were measured as proxies of the deviations between them on true lateral radiographs of the whole femur. Correlation analyses and multivariate regression were carried out to identify predictors of deviations. Significant deviations existed with wide ranges between the anatomical axes and the sagittal mechanical axes. Degree of
Computer navigation has been advocated as a means to improve limb and component alignment and reduce the number of outliers after total knee arthroplasty (TKA). We aimed to determine the alignment outcomes of 1500 consecutive computer-assisted TKAs performed by a single surgeon, using the same implant, with a minimum 1 year follow-up, and to analyze the outliers. Based on radiographic analysis, 112 limbs (7.5%) in 109 patients with mechanical axis malalignment of > 3° were identified and analyzed. The indication for TKA was osteoarthritis in 107 patients and rheumatoid arthritis in 2 patients. Fifty-eight patients (53%) had undergone simultaneous bilateral TKA and 13 patients (12%) had a BMI >30. Preoperative varus deformity was seen in 100 limbs and valgus deformity in 12 limbs. Thirty limbs (27%) had an extra-articular deformity (2 post HTO limbs, 3 malunited fractures, 1 stress fracture, 21 severe
Background Computer navigation is increasingly being recognized as a valuable tool in restoring the mechanical axis post TKR. Its use is as yet not universal due to the costs involved, its availability and the fact that it can be cumbersome and time consuming to use. Additionally it requires the insertion of Schanz pins in the femur as well as the tibia which can be a matter of concern as regards stress fracture and infection. However, it is able to reliably locate the center of the femoral head which is an elusive landmark in the standard method. The center of the ankle involves registration for the medial and lateral malleoli which are subcutaneous and easily palpable. We decided to navigate only the distal femoral cut with a specialized navigation unit called Articular Surface Mounted navigation which does not require the insertion of additional pins through the femur or the tibia. We purposely did not use navigation for the rest of the bony cuts as all the other landmarks i.e. femoral epicondyles, tibial malleoli, and tuberosity etc are all easily palpable. This dramatically reduced the surgical time and increased its user friendliness. We are presenting our results. Aim. To analyse the radiographic results obtained with selective femoral navigation and compare with. standard navigational results from the literature. Non-navigated Knees form personal series. Materials and Methods. We have utilized the ASM navigation for distal femoral cut in 112 knees and obtained long X-rays (scanograms) and routine knee X-rays (AP, Lateral and skyline) to study the mechanical axis and component positioning. We measured the mechanical axis deviation, femoral and tibial angle on AP and lateral films and patellar tilt or subluxation on post-operative X-rays by a digital imaging programme called Image–J. (As suggested by the Knee Society roentgenographic Score). We have compared our results with other navigated series from literature and our own series of non-navigated knees. (113 knees) We also noted the surgical time to perform the operation and the occurrence of any complications. Results. Selective femoral navigation is able to restore the mechanical axis as reliably as other methods of navigation and more reliably than non-navigated knees. On an average, it adds less than 10 minutes to surgical time. Femoral angle, tibial angle patellar tilt and subluxation are similar in both navigated and non-navigated series. Navigation use was not associated with any increased complications and no complication could be ascribed to its use. Selective femoral navigation reduced the outliers in mechanical axis restoration when compared with standard femoral intrameduallry instrumentation. Discussion. Selective distal femoral navigation is a reliable tool in restoring mechanical axis post TKR. It is particularly valuable in knees that have pronounced
We aimed to assess the reliability and validity of OpenPose, a posture estimation algorithm, for measurement of knee range of motion after total knee arthroplasty (TKA), in comparison to radiography and goniometry. In this prospective observational study, we analyzed 35 primary TKAs (24 patients) for knee osteoarthritis. We measured the knee angles in flexion and extension using OpenPose, radiography, and goniometry. We assessed the test-retest reliability of each method using intraclass correlation coefficient (1,1). We evaluated the ability to estimate other measurement values from the OpenPose value using linear regression analysis. We used intraclass correlation coefficients (2,1) and Bland–Altman analyses to evaluate the agreement and error between radiography and the other measurements.Aims
Methods
The Coronal Plane Alignment of the Knee (CPAK) classification is a simple and comprehensive system for predicting pre-arthritic knee alignment. However, when the CPAK classification is applied in the Asian population, which is characterized by more varus and wider distribution in lower limb alignment, modifications in the boundaries of arithmetic hip-knee-ankle angle (aHKA) and joint line obliquity (JLO) should be considered. The purposes of this study were as follows: first, to propose a modified CPAK classification based on the actual joint line obliquity (aJLO) and wider range of aHKA in the Asian population; second, to test this classification in a cohort of Asians with healthy knees; third, to propose individualized alignment targets for different CPAK types in kinematically aligned (KA) total knee arthroplasty (TKA). The CPAK classification was modified by changing the neutral boundaries of aHKA to 0° ± 3° and using aJLO as a new variable. Radiological analysis of 214 healthy knees in 214 Asian individuals was used to assess the distribution and mean value of alignment angles of each phenotype among different classifications based on the coronal plane. Individualized alignment targets were set according to the mean lateral distal femoral angle (LDFA) and medial proximal tibial angle (MPTA) of different knee types.Aims
Methods
Guided growth has been used to treat coxa valga for cerebral palsy (CP) children. However, there has been no study on the optimal position of screw application. In this paper we have investigated the influence of screw position on the outcomes of guided growth. We retrospectively analyzed 61 hips in 32 CP children who underwent proximal femoral hemi epiphysiodesis between July 2012 and September 2017. The hips were divided into two groups according to the transphyseal position of the screw in the coronal plane: across medial quarter (Group 1) or middle quarter (Group 2) of the medial half of the physis. We compared pre- and postoperative radiographs in head-shaft angle (HSA), Reimer’s migration percentage (MP), acetabular index (AI), and femoral anteversion angle (FAVA), as well as incidences of the physis growing-off the screw within two years. Linear and Cox regression analysis were conducted to identify factors related to HSA correction and risk of the physis growing-off the screw.Aims
Methods
The processes linking long-term bisphosphonate treatment to atypical fracture remain elusive. To establish a means of exploring this link, we have examined how long-term bisphosphonate treatment with prior ovariectomy modifies femur fracture behaviour and tibia mass and shape in murine bones. Three groups (seven per group) of 12-week-old mice were: 1) ovariectomized and 20 weeks thereafter treated weekly for 24 weeks with 100 μm/kg subcutaneous ibandronate (OVX+IBN); 2) ovariectomized (OVX); or 3) sham-operated (SHAM). Quantitative fracture analysis generated biomechanical properties for the femoral neck. Tibiae were microCT scanned and trabecular (proximal metaphysis) and cortical parameters along almost its whole length measured.Aims
Methods
This study aimed to evaluate the association between the sagittal alignment of the femoral component in total knee arthroplasty (TKA) and new Knee Society Score (2011KSS), under the hypothesis that outliers such as the excessive extended or flexed femoral component were related to worse clinical outcomes. A group of 156 knees (134 F:22 M) in 133 patients with a mean age 75.8 years (SD 6.4) who underwent TKA with the cruciate-substituting Bi-Surface Knee prosthesis were retrospectively enrolled. On lateral radiographs, γ angle (the angle between the distal femoral axis and the line perpendicular to the distal rear surface of the femoral component) was measured, and the patients were divided into four groups according to the γ angle. The 2011KSSs among groups were compared using the Kruskal-Wallis test. A secondary regression analysis was used to investigate the association between the 2011KSS and γ angle.Aims
Methods
Double-level lengthening, bone transport, and bifocal compression-distraction are commonly undertaken using Ilizarov or other fixators. We performed double-level fixator-assisted nailing, mainly for the correction of deformity and lengthening in the same segment, using a straight intramedullary nail to reduce the time in a fixator. A total of 23 patients underwent this surgery, involving 27 segments (23 femora and four tibiae), over a period of ten years. The most common indication was polio in ten segments and rickets in eight; 20 nails were inserted retrograde and seven antegrade. A total of 15 lengthenings were performed in 11 femora and four tibiae, and 12 double-level corrections of deformity without lengthening were performed in the femur. The mean follow-up was 4.9 years (1.1 to 11.4). Four patients with polio had tibial lengthening with arthrodesis of the ankle. We compared the length of time in a fixator and the external fixation index (EFI) with a control group of 27 patients (27 segments) who had double-level procedures with external fixation. The groups were matched for the gain in length, age, and level of difficulty score.Aims
Patients and Methods
Cement thickness of at least 2 mm is generally associated with more favorable results for the femoral component in cemented hip arthroplasty. However, French-designed stems have shown favorable outcomes even with thin cement mantle. The biomechanical behaviors of a French stem, Charnley-Marcel-Kerboull (CMK) and cement were researched in this study. Six polished CMK stems were implanted into a composite femur, and one million times dynamic loading tests were performed. Stem subsidence and the compressive force at the bone-cement interface were measured. Tantalum ball (ball) migration in the cement was analyzed by micro CTObjective
Methods