header advert
Results 1 - 50 of 2205
Results per page:
The Bone & Joint Journal
Vol. 105-B, Issue 3 | Pages 277 - 283
1 Mar 2023
Gausden EB Puri S Chiu Y Figgie MP Sculco TP Westrich G Sculco PK Chalmers BP

Aims. The purpose of this study was to assess mid-term survivorship following primary total knee arthroplasty (TKA) with Optetrak Logic components and identify the most common revision indications at a single institution. Methods. We identified a retrospective cohort of 7,941 Optetrak primary TKAs performed from January 2010 to December 2018. We reviewed the intraoperative findings of 369 TKAs that required revision TKA from January 2010 to December 2021 and the details of the revision implants used. Kaplan-Meier analysis was used to determine survivorship. Cox regression analysis was used to examine the impact of patient variables and year of implantation on survival time. Results. The estimated survivorship free of all-cause revision was 98% (95% confidence interval (CI) 97% to 98%), 95% (95% CI 95% to 96%), and 86% (95% CI 83% to 88%) at two, five, and ten years, respectively. In 209/369 revisions there was a consistent constellation of findings with varying severity that included polyethylene wear and associated synovitis, osteolysis, and component loosening. This failure mode, which we refer to as aseptic mechanical failure, was the most common revision indication. The mean time from primary TKA to revision for aseptic mechanical failure was five years (5 months to 11 years). Conclusion. In this series of nearly 8,000 primary TKAs performed with a specific implant, we identified a lower-than-expected mid-term survivorship and a high number of revisions with a unique presentation. This study, along with the recent recall of the implant, confirms the need for frequent monitoring of patients with Optetrak TKAs given the incidence of polyethylene failure, osteolysis, and component loosening. Cite this article: Bone Joint J 2023;105-B(3):277–283


Aims. The aim of this study was to evaluate medium-term outcomes and complications of the S-ROM NOILES Rotating Hinge Knee System (DePuy, USA) in revision total knee arthroplasty (rTKA) at a tertiary unit. Methods. A retrospective consecutive study of all patients who underwent a rTKA using this implant from January 2005 to December 2018. Outcome measures included reoperations, revision for any cause, complications, and survivorship. Patients and implant survivorship data were identified through both local hospital electronic databases and linked data from the National Joint Registry/NHS Personal Demographic Service. Kaplan-Meier survival analysis was used at ten years. Results. A total of 89 consecutive patients (89 knees) were included with 47 females (52.8%) and a median age of 74 years (interquartile range 66 to 79). The main indications were aseptic loosening with instability (39.4%; n = 35) and infection (37.1%; n = 33) with the majority of patients managed through two-stage approach. The mean follow-up was 7.4 years (2 to 16). The overall rate of reoperation, for any cause, was 10.1% (n = 9) with a rate of implant revision of 6.7% (n = 6). Only two cases required surgery for patellofemoral complications. Kaplan-Meier implant-survivorship analysis was 93.3% at ten years, using revision for any cause as an endpoint. Conclusion. This implant achieved high ten-year survivorship with a low complication rate, particularly patellofemoral complications. These can be avoided by ensuring central patella tracking and appropriate tension of the patellofemoral joint in this posterior hinge design. Cite this article: Bone Jt Open 2022;3(3):205–210


The Bone & Joint Journal
Vol. 103-B, Issue 2 | Pages 338 - 346
1 Feb 2021
Khow YZ Liow MHL Lee M Chen JY Lo NN Yeo SJ

Aims. This study aimed to identify the tibial component and femoral component coronal angles (TCCAs and FCCAs), which concomitantly are associated with the best outcomes and survivorship in a cohort of fixed-bearing, cemented, medial unicompartmental knee arthroplasties (UKAs). We also investigated the potential two-way interactions between the TCCA and FCCA. Methods. Prospectively collected registry data involving 264 UKAs from a single institution were analyzed. The TCCAs and FCCAs were measured on postoperative radiographs and absolute angles were analyzed. Clinical assessment at six months, two years, and ten years was undertaken using the Knee Society Knee score (KSKS) and Knee Society Function score (KSFS), the Oxford Knee Score (OKS), the 36-Item Short-Form Health Survey questionnaire (SF-36), and range of motion (ROM). Fulfilment of expectations and satisfaction was also recorded. Implant survivorship was reviewed at a mean follow-up of 14 years (12 to 16). Multivariate regression models included covariates, TCCA, FCCA, and two-way interactions between them. Partial residual graphs were generated to identify angles associated with the best outcomes. Kaplan-Meier analysis was used to compare implant survivorship between groups. Results. Significant two-way interaction effects between TCCA and FCCA were identified. Adjusted for each other and their interaction, a TCCA of between 2° and 4° and a FCCA of between 0° and 2° were found to be associated with the greatest improvements in knee scores and the probability of fulfilling expectations and satisfaction at ten years. Patients in the optimal group whose TCCA and FCCA were between 2° and 4°, and 0° and 2°, respectively, had a significant survival benefit at 15 years compared with the non-optimal group (optimal: survival = 100% vs non-optimal: survival = 92%, 95% confidence interval (CI) 88% to 96%). Conclusion. Significant two-way interactions between the TCCA and FCCA demonstrate the importance of evaluating the alignment of the components concomitantly in future studies. By doing so, we found that patients who concomitantly had both a TCCA of between 2° and 4° and a FCCA of between 0° and 2° had the best patient-reported outcome measures at ten years and better survivorship at 15 years. Cite this article: Bone Joint J 2021;103-B(2):338–346


The Bone & Joint Journal
Vol. 102-B, Issue 1 | Pages 108 - 116
1 Jan 2020
Burger JA Kleeblad LJ Laas N Pearle AD

Aims. Limited evidence is available on mid-term outcomes of robotic-arm assisted (RA) partial knee arthroplasty (PKA). Therefore, the purpose of this study was to evaluate mid-term survivorship, modes of failure, and patient-reported outcomes of RA PKA. Methods. A retrospective review of patients who underwent RA PKA between June 2007 and August 2016 was performed. Patients received a fixed-bearing medial or lateral unicompartmental knee arthroplasty (UKA), patellofemoral arthroplasty (PFA), or bicompartmental knee arthroplasty (BiKA; PFA plus medial UKA). All patients completed a questionnaire regarding revision surgery, reoperations, and level of satisfaction. Knee Injury and Osteoarthritis Outcome Scores (KOOS) were assessed using the KOOS for Joint Replacement Junior survey. Results. Mean follow-up was 4.7 years (2.0 to 10.8). Five-year survivorship of medial UKA (n = 802), lateral UKA (n = 171), and PFA/BiKA (n = 35/10) was 97.8%, 97.7%, and 93.3%, respectively. Component loosening and progression of osteoarthritis (OA) were the most common reasons for revision. Mean KOOS scores after medial UKA, lateral UKA, and PFA/BiKA were 84.3 (SD 15.9), 85.6 (SD 14.3), and 78.2 (SD 14.2), respectively. The vast majority of the patients reported high satisfaction levels after RA PKA. Subgroup analyses suggested tibial component design, body mass index (BMI), and age affects RA PKA outcomes. Five-year survivorship was 98.4% (95% confidence interval (CI) 97.2 to 99.5) for onlay medial UKA (n = 742) and 99.1% (95% CI 97.9 to 100) for onlay medial UKA in patients with a BMI < 30 kg/m. 2. (n = 479). Conclusion. This large single-surgeon study showed high mid-term survivorship, satisfaction levels, and functional outcomes in RA UKA using metal-backed tibial onlay components. In addition, favourable results were reported in RA PFA and BiKA. Cite this article: Bone Joint J 2020;102-B(1):108–116


The Bone & Joint Journal
Vol. 101-B, Issue 10 | Pages 1186 - 1191
1 Oct 2019
Amstutz HC Le Duff MJ

Aims. In previous studies, we identified multiple factors influencing the survivorship of hip resurfacing arthroplasties (HRAs), such as initial anatomical conditions and surgical technique. In addition, the University of California, Los Angeles (UCLA) activity score presents a ceiling effect, so a better quantification of activity is important to determine which activities may be advisable or detrimental to the recovered patient. We aimed to determine the effect of specific groups of sporting activities on the survivorship free of aseptic failure of a large series of HRA. Patients and Methods. A total of 661 patients (806 hips) representing 77% of a consecutive series of patients treated with metal-on-metal hybrid HRA answered a survey to determine the types and amounts of sporting activities they regularly participated in. There were 462 male patients (70%) and 199 female patients (30%). Their mean age at the time of surgery was 51.9 years (14 to 78). Their mean body mass index (BMI) was 26.5 kg/m. 2. (16.7 to 46.5). Activities were regrouped into 17 categories based on general analogies between these activities. Scores for typical frequency and duration of the sessions were used to quantify the patients’ overall time spent engaging in sporting activities. Impact and cycle scores were computed. Multivariable models were used. Results. We found no association between any category of activity and a decrease in survivorship. Impact and hip cycle scores also failed to show any association with revision for aseptic failure or wear. Conclusion. Return to sporting activities after surgery is safe for patients treated with well-designed and well-implanted HRA. Cite this article: Bone Joint J 2019;101-B:1186–1191


The Bone & Joint Journal
Vol. 100-B, Issue 4 | Pages 450 - 454
1 Apr 2018
Chalmers BP Mehrotra KG Sierra RJ Pagnano MW Taunton MJ Abdel MP

Aims. Primary (or spontaneous) and secondary osteonecrosis of the knee can lead to severe joint degeneration, for which either total or unicompartmental arthroplasty may be considered. However, there are limited studies analyzing outcomes of unicompartmental knee arthroplasties (UKAs) for osteonecrosis involving an isolated compartment of the knee. The aims of this study were to analyze outcomes of UKAs for osteonecrosis with specific focus on 1) survivorship free of any revision or reoperation, 2) risk factors for failure, 3) clinical outcomes, and 4) complications. Patients and Methods. A total of 45 patients underwent 46 UKAs for knee osteonecrosis between 2002 and 2014 at our institution (The Mayo Clinic, Rochester, Minnesota). Twenty patients (44%) were female; the mean age of the patients was 66 years, and mean body mass index (BMI) was 31 kg/m. 2. Of the 46 UKAs, 44 (96%) were medial UKAs, and 35 (76%) were fixed-bearing design. Mean mechanical axis postoperatively was 1.5° varus (0° to 5° varus); 41 UKAs (89%) were performed for primary osteonecrosis. Mean follow-up was five years (2 to 12). Results. Survivorship free of any revision in the cohort was 89% (95% CI 77 to 99) and 76% (95% CI 53 to 99) at five and ten years, respectively. In patients undergoing UKA for primary osteonecrosis survivorship free of any revision was 93% (95% CI 83 to 100)at both five and ten years. Secondary osteonecrosis was a significant risk factor for poorer survivorship free of any revision or reoperation (hazard ratio 7.7, p = 0.03). Three medial UKAs (6.5%) were converted to total knee arthroplasties (TKAs): two for lateral compartment degeneration and one for development of lateral osteonecrosis. No implants were revised for loosening, fracture, or wear. Knee Society scores improved from a mean of 60 (44 to 72) preoperatively to a mean of 94 postoperatively (82 to 100) (p < 0.001). There were no surgical complications. Conclusion. When done for primary osteonecrosis of the knee, UKA resulted in reliable clinical improvement, minimal complications, and durable estimated implant survivorship free of revision at ten years. UKA done for secondary osteonecrosis was substantially less durable at mid-term follow-up. Progression of knee degeneration, rather than implant failure or loosening, was most common indication for conversion to TKA. Cite this article: Bone Joint J 2018;100-B:450–4


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 11 | Pages 1517 - 1521
1 Nov 2012
Niinimäki TT Eskelinen A Mann BS Junnila M Ohtonen P Leppilahti J

Previous studies from single centres or single-surgeon series report good early and mid-term results for high tibial osteotomy (HTO) in the treatment of osteoarthritis of the knee. However, the survivorship of HTO at a national level is unknown. This registry-based study included 3195 high HTOs performed between 1987 and 2008. Kaplan-Meier analysis revealed an overall survivorship of 89% (95% confidence interval (CI) 88 to 90) at five years and 73% (95% CI 72 to 75) at ten years, when conversion to total knee replacement was taken as the endpoint. Females and patients aged > 50 years had worse survivorship than males or patients aged ≤ 50 years (hazard ratio (HR) 1.26 (95% CI 1.11 to 1.43) and HR 1.41 (95% CI 1.23 to 1.64), respectively). The survivorship of HTOs performed between 1998 to 2008 was worse than for those performed between 1987 and 1997


Bone & Joint Research
Vol. 3, Issue 5 | Pages 150 - 154
1 May 2014
M. Takamura K Maher P Nath T Su EP

Objectives. Metal-on-metal hip resurfacing (MOMHR) is available as an alternative option for younger, more active patients. There are failure modes that are unique to MOMHR, which include loosening of the femoral head and fractures of the femoral neck. Previous studies have speculated that changes in the vascularity of the femoral head may contribute to these failure modes. This study compares the survivorship between the standard posterior approach (SPA) and modified posterior approach (MPA) in MOMHR. . Methods. A retrospective clinical outcomes study was performed examining 351 hips (279 male, 72 female) replaced with Birmingham Hip Resurfacing (BHR, Smith and Nephew, Memphis, Tennessee) in 313 patients with a pre-operative diagnosis of osteoarthritis. The mean follow-up period for the SPA group was 2.8 years (0.1 to 6.1) and for the MPA, 2.2 years (0.03 to 5.2); this difference in follow-up period was statistically significant (p < 0.01). Survival analysis was completed using the Kaplan–Meier method. . Results. At four years, the Kaplan–Meier survival curve for the SPA was 97.2% and 99.4% for the MPA; this was statistically significant (log-rank; p = 0.036). There were eight failures in the SPA and two in the MPA. There was a 3.5% incidence of femoral head collapse or loosening in the SPA and 0.4% in the MPA, which represented a significant difference (p = 0.041). There was a 1.7% incidence of fractures of the femoral neck in the SPA and none in the MPA (p = 0.108). . Conclusion. This study found a significant difference in survivorship at four years between the SPA and the MPA (p = 0.036). The clinical outcomes of this study suggest that preserving the vascularity of the femoral neck by using the MPA results in fewer vascular-related failures in MOMHRs. Cite this article: Bone Joint Res 2014;3:150–4


The Bone & Joint Journal
Vol. 101-B, Issue 10 | Pages 1184 - 1185
1 Oct 2019
Amstutz HC Le Duff MJ


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_6 | Pages 33 - 33
2 May 2024
Dickenson E Griffin J Wall P McBryde C
Full Access

The 22 year survivorship of metal on metal hip resurfacing arthroplasty (RSA) is reported to be 94.3% with expert surgeons, in males with head sizes greater than 48mm. The 2023 National Joint Registry (NJR) report estimates survivorship of all RSA at 19 years to be 85%. This estimate includes all designs, head sizes and females. Our aim was to estimate the survivorship of RSA currently available for implantation (males only, head size >48mm, MatOrtho Adept or Smith and Nephew Birmingham Hip Resurfacing (BHR)) in those under 55 years, performed by all surgeons, compared to conventional THR. We performed a retrospective analysis of the NJR. We included all males under 55 years who had undergone BHR or Adept RSA with head size greater than 48mm. Propensity score matching was used to produce two comparable groups of patients for RSA or conventional THR. We matched in a 3:1 ratio (THR:RSA) using sex, ASA, BMI group, age at primary procedure, surgeon volume, diagnosis and surgeon grade as covariates. The primary analysis was survivorship at 18 years. Time-to-revision was assessed using Kaplan-Meier curves. Cox's proportional hazard models were used to investigate between group differences. 4839 RSA were available for analysis. After matching the RSA and THR groups were well balanced in terms of covariates. Survivorship at 18 years was 93.7% (95% CI 89.9,96.2) in the RSA group and 93.9% (90.5,96.0) in the THR group. Despite these similar estimates the adjusted hazard ratio was 1.40 (95% CI 1.18, 1.67 p<0.001) in favour of THR. Survivorship of the currently available RSA in males under 55 was 93.7% at 18 years, however THR survivorship was superior to RSA. These results, generalisable to UK practice, should be set against perceived benefits in functional status offered in RSA when counselling patients


Bone & Joint Open
Vol. 3, Issue 3 | Pages 173 - 181
1 Mar 2022
Sobol KR Fram BR Strony JT Brown SA

Aims. Endoprosthetic reconstruction with a distal femoral arthroplasty (DFA) can be used to treat distal femoral bone loss from oncological and non-oncological causes. This study reports the short-term implant survivorship, complications, and risk factors for patients who underwent DFA for non-neoplastic indications. Methods. We performed a retrospective review of 75 patients from a single institution who underwent DFA for non-neoplastic indications, including aseptic loosening or mechanical failure of a previous prosthesis (n = 25), periprosthetic joint infection (PJI) (n = 23), and native or periprosthetic distal femur fracture or nonunion (n = 27). Patients with less than 24 months’ follow-up were excluded. We collected patient demographic data, complications, and reoperations. Reoperation for implant failure was used to calculate implant survivorship. Results. Overall one- and five-year implant survivorship was 87% and 76%, respectively. By indication for DFA, mechanical failure had one- and five-year implant survivorship of 92% and 68%, PJI of 91% and 72%, and distal femur fracture/nonunion of 78% and 70% (p = 0.618). A total of 37 patients (49%) experienced complications and 27 patients (36%) required one or more reoperation. PJI (n = 16, 21%), aseptic loosening (n = 9, 12%), and wound complications (n = 8, 11%) were the most common complications. Component revision (n = 10, 13.3%) and single-stage exchange for PJI (n = 9, 12.0 %) were the most common reoperations. Only younger age was significantly associated with increased complications (mean 67 years (SD 9.1)) with complication vs 71 years (SD 9.9) without complication; p = 0.048). Conclusion. DFA is a viable option for distal femoral bone loss from a range of non-oncological causes, demonstrating acceptable short-term survivorship but with high overall complication rates. Cite this article: Bone Jt Open 2022;3(3):173–181


Bone & Joint Open
Vol. 4, Issue 11 | Pages 853 - 858
10 Nov 2023
Subbiah Ponniah H Logishetty K Edwards TC Singer GC

Aims. Metal-on-metal hip resurfacing (MoM-HR) has seen decreased usage due to safety and longevity concerns. Joint registries have highlighted the risks in females, smaller hips, and hip dysplasia. This study aimed to identify if reported risk factors are linked to revision in a long-term follow-up of MoM-HR performed by a non-designer surgeon. Methods. A retrospective review of consecutive MoM hip arthroplasties (MoM-HRAs) using Birmingham Hip Resurfacing was conducted. Data on procedure side, indication, implant sizes and orientation, highest blood cobalt and chromium ion concentrations, and all-cause revision were collected from local and UK National Joint Registry records. Results. A total of 243 hips (205 patients (163 male, 80 female; mean age at surgery 55.3 years (range 25.7 to 75.3)) with MoM-HRA performed between April 2003 and October 2020 were included. Mean follow-up was 11.2 years (range 0.3 to 17.8). Osteoarthritis was the most common indication (93.8%), and 13 hips (5.3%; 7M:6F) showed dysplasia (lateral centre-edge angle < 25°). Acetabular cups were implanted at a median of 45.4° abduction (interquartile range 41.9° - 48.3°) and stems neutral or valgus to the native neck-shaft angle. In all, 11 hips (4.5%; one male, ten females) in ten patients underwent revision surgery at a mean of 7.4 years (range 2.8 to 14.2), giving a cumulative survival rate of 94.8% (95% confidence interval (CI) 91.6% to 98.0%) at ten years, and 93.4% (95% CI 89.3% to 97.6%) at 17 years. For aseptic revision, male survivorship was 100% at 17 years, and 89.6% (95% CI 83.1% to 96.7%) at ten and 17 years for females. Increased metal ion levels were implicated in 50% of female revisions, with the remaining being revised for unexplained pain or avascular necrosis. Conclusion. The Birmingham MoM-HR showed 100% survivorship in males, exceeding the National Institute for Health and Care Excellence ‘5% at ten years’ threshold. Female sex and small component sizes are independent risk factors. Dysplasia alone is not a contraindication to resurfacing. Cite this article: Bone Jt Open 2023;4(11):853–858


Bone & Joint Open
Vol. 3, Issue 8 | Pages 656 - 665
23 Aug 2022
Tran T McEwen P Peng Y Trivett A Steele R Donnelly W Clark G

Aims. The mid-term results of kinematic alignment (KA) for total knee arthroplasty (TKA) using image derived instrumentation (IDI) have not been reported in detail, and questions remain regarding ligamentous stability and revisions. This paper aims to address the following: 1) what is the distribution of alignment of KA TKAs using IDI; 2) is a TKA alignment category associated with increased risk of failure or poor patient outcomes; 3) does extending limb alignment lead to changes in soft-tissue laxity; and 4) what is the five-year survivorship and outcomes of KA TKA using IDI?. Methods. A prospective, multicentre, trial enrolled 100 patients undergoing KA TKA using IDI, with follow-up to five years. Alignment measures were conducted pre- and postoperatively to assess constitutional alignment and final implant position. Patient-reported outcome measures (PROMs) of pain and function were also included. The Australian Orthopaedic Association National Joint Arthroplasty Registry was used to assess survivorship. Results. The postoperative HKA distribution varied from 9° varus to 11° valgus. All PROMs showed statistical improvements at one year (p < 0.001), with further improvements at five years for Knee Osteoarthritis Outcome Score symptoms (p = 0.041) and Forgotten Joint Score (p = 0.011). Correlation analysis showed no difference (p = 0.610) between the hip-knee-ankle and joint line congruence angle at one and five years. Sub-group analysis showed no difference in PROMs for patients placed within 3° of neutral compared to those placed > 3°. There were no revisions for tibial loosening; however, there were reports of a higher incidence of poor patella tracking and patellofemoral stiffness. Conclusion. PROMs were not impacted by postoperative alignment category. Ligamentous stability was maintained at five years with joint line obliquity. There were no revisions for tibial loosening despite a significant portion of tibiae placed in varus; however, KA executed with IDI resulted in a higher than anticipated rate of patella complications. Cite this article: Bone Jt Open 2022;3(8):656–665


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_13 | Pages 31 - 31
1 Dec 2022
Tat J Hall J
Full Access

Open debridement and Outerbridge and Kashiwagi debridement arthroplasty (OK procedure) are common surgical treatments for elbow arthritis. However, the literature contains little information on the long-term survivorship of these procedures. The purpose of this study was to determine the survivorship after elbow debridement techniques until conversion to total elbow arthroplasty and revision surgery. We performed a retrospective chart review of patients who underwent open elbow surgical debridement (open debridement, OK procedure) between 2000 and 2015. Patients were diagnosed with primary elbow osteoarthritis, post-traumatic arthritis, or inflammatory arthritis. A total of 320 patients had primary surgery including open debridement (n=142) and OK procedure (n=178), and of these 33 patients required a secondary revision surgery (open debridement, n=14 and OK procedure, n=19). The average follow-up time was 11.5 years (5.5 - 21.5 years). Survivorship was analyzed with Kaplan-Meier curves and Log Rank test. A Cox proportional hazards model was used assess the likelihood of conversion to total elbow arthroplasty or revision surgery while adjusting for covariates (age, gender, diagnosis). Significance was set p<0.05. Kaplan-Meier survival curves showed open debridement was 100.00% at 1 year, 99.25% at 5 years, and 98.49% at 10 years and for OK procedure 100.00% at 1 year, 98.80% at 5 years, 97.97% at 10 years (p=0.87) for conversion to total elbow arthroplasty. There was no difference in survivorship between procedures after adjusting for significant covariates with the cox proportional hazard model. The rate of revision for open debridement and OK procedure was similar at 11.31% rand 11.48% after 10 years respectively. There were higher rates of revision surgery in patients with open debridement (hazard ratio, 4.84 CI 1.29 – 18.17, p = 0.019) compared to OK procedure after adjusting for covariates. We also performed a stratified analysis with radiographic severity as an effect modifier and showed grade 3 arthritis did better with the OK procedure compared to open debridement for survivorship until revision surgery (p=0.05). However, this difference was not found for grade 1 or grade 2 arthritis. This may suggest that performing the OK procedure for more severe grade 3 arthritis could decrease reoperation rates. Further investigations are needed to better understand the indications for each surgical technique. This study is the largest cohort of open debridement and OK procedure with long term follow-up. We showed that open elbow debridement and the OK procedure have excellent survivorship until conversion to total elbow arthroplasty and are viable options in the treatment of primary elbow osteoarthritis and post traumatic cases. The OK procedure also has lower rates of revision surgery than open debridement, especially with more severe radiographic arthritis


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_12 | Pages 56 - 56
1 Dec 2022
Tat J Hall J
Full Access

Open debridement and Outerbridge and Kashiwagi debridement arthroplasty (OK procedure) are common surgical treatments for elbow arthritis. However, the literature contains little information on the long-term survivorship of these procedures. The purpose of this study was to determine the survivorship after elbow debridement techniques until conversion to total elbow arthroplasty and revision surgery. We performed a retrospective chart review of patients who underwent open elbow surgical debridement (open debridement, OK procedure) between 2000 and 2015. Patients were diagnosed with primary elbow osteoarthritis, post-traumatic arthritis, or inflammatory arthritis. A total of 320 patients had primary surgery including open debridement (n=142) and OK procedure (n=178), and of these 33 patients required a secondary revision surgery (open debridement, n=14 and OK procedure, n=19). The average follow-up time was 11.5 years (5.5 - 21.5 years). Survivorship was analyzed with Kaplan-Meier curves and Log Rank test. A Cox proportional hazards model was used assess the likelihood of conversion to total elbow arthroplasty or revision surgery while adjusting for covariates (age, gender, diagnosis). Significance was set p<0.05. Kaplan-Meier survival curves showed open debridement was 100.00% at 1 year, 99.25% at 5 years, and 98.49% at 10 years and for OK procedure 100.00% at 1 year, 98.80% at 5 years, 97.97% at 10 years (p=0.87) for conversion to total elbow arthroplasty. There was no difference in survivorship between procedures after adjusting for significant covariates with the cox proportional hazard model. The rate of revision for open debridement and OK procedure was similar at 11.31% rand 11.48% after 10 years respectively. There were higher rates of revision surgery in patients with open debridement (hazard ratio, 4.84 CI 1.29 - 18.17, p = 0.019) compared to OK procedure after adjusting for covariates. We also performed a stratified analysis with radiographic severity as an effect modifier and showed grade 3 arthritis did better with the OK procedure compared to open debridement for survivorship until revision surgery (p=0.05). However, this difference was not found for grade 1 or grade 2 arthritis. This may suggest that performing the OK procedure for more severe grade 3 arthritis could decrease reoperation rates. Further investigations are needed to better understand the indications for each surgical technique. This study is the largest cohort of open debridement and OK procedure with long term follow-up. We showed that open elbow debridement and the OK procedure have excellent survivorship until conversion to total elbow arthroplasty and are viable options in the treatment of primary elbow osteoarthritis and post traumatic cases. The OK procedure also has lower rates of revision surgery than open debridement, especially with more severe radiographic arthritis


The Bone & Joint Journal
Vol. 104-B, Issue 6 | Pages 680 - 686
1 Jun 2022
Robinson JR Bruce D Davies H Porteous AJ Murray JRD Howells NR

Aims. The best surgical strategy for the management of displaced bucket-handle (BH) meniscal tears in an anterior cruciate ligament (ACL)-deficient knee is unclear. Combining meniscal repair with ACL reconstruction (ACLR) is thought to improve meniscal healing rates; however, patients with displaced BH meniscal tears may lack extension. This leads some to advocate staged surgery to avoid postoperative stiffness and loss of range of motion (ROM) following ACLR. Methods. We reviewed the data for a consecutive series of 88 patients (mean age 27.1 years (15 to 49); 65 male (74%) and 23 female (26%)) who underwent single-stage repair of a displaced BH meniscal tear (67 medial (76%) and 21 lateral (24%)) with concomitant hamstring autograft ACLR. The patient-reported outcome measures (PROMs) EuroQol visual analogue scale (EQ-VAS), EuroQol five-dimension health questionnaire (EQ-5D), Knee injury and Osteoarthritis Outcome Score (KOOS), International Knee Documentation Committee score (IKDC), and Tegner score were recorded at final follow-up. A Kaplan-Meier survival analysis was performed to estimate meniscal repair survivorship. Analyses were performed with different cut-offs for meniscal and ACL injury-to-surgery time (within three weeks, three to ten weeks, and more than ten weeks). Results. Meniscal repair survivorship at a median final follow-up of 55 months (interquartile range (IQR) 24 to 91) was 82% (95% confidence interval 70 to 89). A total of 13 meniscus repairs failed (12 requiring meniscectomy and one requiring a further meniscal repair). At final follow-up, median PROMs were: EQ-VAS 85 (IQR 75 to 90), EQ-5D Index 0.84 (IQR 0.74 to 1.00), KOOS Pain 89 (IQR 80 to 94), KOOS Symptoms 82 (IQR 71 to 93), KOOS Activities of Daily Living 97 (IQR 91 to 100), KOOS Sport and Recreation 80 (IQR 65 to 90), KOOS Quality of Life 69 (IQR 53 to 86), IKDC 82.8 (IQR 67.8 to 90.8), and Tegner 6 (IQR 4 to 7). Two patients underwent revision ACLR following further injuries. One patient had an arthroscopic washout for infection at 11 days post-BH meniscal repair/ACLR. Four patients (4.5%) required a further procedure for stiffness, reduced ROM, and pain, and all were operated on within three weeks of meniscal injury. There was no difference in the interval between meniscal injury and surgery between repairs that failed and those that survived. Conclusion. These data suggest that concomitant ACLR with repair of displaced BH meniscal tears, even if they have been displaced for some time, appears to afford satisfactory PROMs and good survivorship. Repairs within three weeks of meniscal injury may be associated with higher rates of postoperative reintervention for stiffness. Cite this article: Bone Joint J 2022;104-B(6):680–686


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_3 | Pages 16 - 16
23 Feb 2023
Tay M Bolam S Coleman B Munro J Monk A Hooper G Young S
Full Access

Source of the study: University of Auckland, Auckland, New Zealand. Unicompartmental knee arthroplasty (UKA) is effective for patients with isolated compartment osteoarthritis, however the procedure has higher revision rates. Long-term survivorship and accurate characterisation of revision reasons are limited by a lack of long-term data and standardised revision definitions. We aimed to identify survivorship, risk factors and revision reasons in a large UKA cohort with up to 20 years follow-up. Patient, implant and revision details were recorded through clinical and radiological review for 2,137 consecutive patients undergoing primary medial UKA across Auckland, Canterbury, Counties Manukau and Waitematā DHB between 2000 and 2017. Revision reasons were determined from review of clinical, laboratory, and radiological records for each patient using a standardised protocol. To ensure complete follow-up data was cross-referenced with the New Zealand Joint Registry to identify patients undergoing subsequent revision outside the hospitals. Implant survival, revision risk and revision reasons were analysed using Cox proportional-hazards and competing risk analyses. Implant survivorship at 15 years was comparable for cemented fixed-bearing (cemFB; 91%) and uncemented mobile-bearing (uncemMB; 91%), but lower for cemented mobile-bearing (cemMB; 80%) implants. There was higher incidence of aseptic loosening with cemented implants (3–4% vs. 0.4% uncemented, p<0.01), osteoarthritis (OA) progression with cemMB implants (9% vs. 3% cemFB/uncemMB; p<0.05) and bearing dislocations with uncemMB implants (3% vs. 2% cemMB, p=0.02). Compared with the oldest patients (≥75 years), there was a nearly two-fold increase in risk for those aged 55–64 (hazard ratio 1.9; confidence interval 1.1-3.3, p=0.03). No association was found with gender, BMI or ASA. Cemented mobile-bearing implants and younger age were linked to lower implant survivorship. These were associated with disease progression and bearing dislocations. The use of cemented fixed-bearing and uncemented mobile-bearing designs have superior comparable long-term survivorship


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_7 | Pages 38 - 38
1 Jul 2022
Fu H Peacock C Wang C Kader D Clement N Asopa V Sochart D
Full Access

Abstract. Aim. End-stage arthropathy is a well-known complication of haemophilia, with recurrent haemarthroses leading to joint destruction, deformity, pain, and stiffness. In the knee, this is often treated with total knee arthroplasty (TKA), which can be more challenging in patients with haemophilia (PwH) and associated with poorer outcomes. We conducted a systematic literature review and meta-analysis to determine implant survivorship, functional outcomes and complication rates. Method. A systematic review was conducted using MEDLINE, EMBASE, and PubMed for studies reporting TKA outcomes with Kaplan-Meier survivorship in PwH (PROSPERO registered). Meta-analysis was performed for survivorship and outcomes, and the results were compared to outcomes from the National Joint Registry (NJR). Results. 19 studies, totalling 1187 TKAs (average age 39 years) were reviewed. In PwH, implant survivorship at 5, 10, and 15 years was 94%, 86%, and 76% respectively, whereas NJR reported survivorship for males <55 years was 94%, 90%, and 86%. Survivorship generally improved over the time period studied (1973–2017), but was inversely correlated with HIV infection (common in PwH). Range of motion improved by 10–20° post-operatively, and there were large improvements in Patient Reported Outcome Measures (PROMS). The prosthetic joint infection rate (PJI) was 6% compared to 0.5-1% in non-PwH, but the reporting of other complications, especially haematological, was inconsistent. Conclusions. TKA in PwH has similar 5-year survivorship to non-PwH, but a six-fold higher infection rate. There were marked improvements in range of motion and PROMS, but complications were poorly reported. There remains a need for larger, long-term studies with standardised reporting


The Bone & Joint Journal
Vol. 102-B, Issue 6 Supple A | Pages 107 - 115
1 Jun 2020
Tetreault MW Perry KI Pagnano MW Hanssen AD Abdel MP

Aims. Metaphyseal fixation during revision total knee arthroplasty (TKA) is important, but potentially difficult when using historical designs of cone. Material and manufacturing innovations have improved the size and shape of the cones which are available, and simplified the required bone preparation. In a large series, we assessed the implant survivorship, radiological results, and clinical outcomes of new porous 3D-printed titanium metaphyseal cones featuring a reamer-based system. Methods. We reviewed 142 revision TKAs in 139 patients using 202 cones (134 tibial, 68 femoral) which were undertaken between 2015 and 2016. A total of 60 involved tibial and femoral cones. Most cones (149 of 202; 74%) were used for Type 2B or 3 bone loss. The mean age of the patients was 66 years (44 to 88), and 76 (55 %) were female. The mean body mass index (BMI) was 34 kg/m. 2. (18 to 60). The patients had a mean of 2.4 (1 to 8) previous operations on the knee, and 68 (48%) had a history of prosthetic infection. The mean follow-up was 2.4 years (2 to 3.6). Results. Survivorship free of cone revision for aseptic loosening was 100% and survivorship free of any cone revision was 98%. Survivorships free of any revision and any reoperation were 90% and 83%, respectively. Five cones were revised: three for infection, one for periprosthetic fracture, and one for aseptic tibial loosening. Radiologically, three unrevised femoral cones appeared loose in the presence of hinged implants, while the remaining cones appeared stable. All cases of cone loosening occurred in patients with Type 2B or 3 defects. The mean Knee Society score (KSS) improved significantly from 50 (0 to 94) preoperatively to 87 (72 to 94) (p < 0.001). Three intraoperative fractures with cone impaction (two femoral, one tibial) healed uneventfully. Conclusion. Novel 3D-printed titanium cones, with a reamer-based system, yielded excellent early survivorship and few complications in patients with severe bone loss undergoing difficult revision TKA. The diversity of cone options, relative ease of preparation, and outcomes rivalling those of previous designs of cone support their continued use. Cite this article: Bone Joint J 2020;102-B(6 Supple A):107–115


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_11 | Pages 51 - 51
1 Nov 2022
Jagadeesh N Pammi S Kariya A Sales R
Full Access

Abstract. Background. The primary objective of the study is to determine the function outcome and survivorship of patellofemoral replacement. The secondary aim is to find the determinants of successful/poor outcome. Methods. This retrospective study involved 45 patients who underwent AVON patellofemoral replacement between January 2015 to December 2020 with the minimal follow-up off for 12 months. The functional outcome was measured using Oxford Knee score (OKS), EuroQol five dimension (EQ-5D). IWANO and Kellgren-Lawrence classification was used to analyse radiographs. To identify determinants of outcome, the following subgroups the presence or absence of normal alignment, tibiofemoral arthritis, trochlear dysplasia and previous surgery. Complications and revision rates were also recorded. Results. The mean follow-up period was 41.7 +/− 8.3 months with no patients lost in follow-up. Patellofemoral replacement significantly improved the Oxford Knee score (OKS), EuroQol five dimension (EQ-5D) (p<0.001). Four out of 45(8.9%) patients underwent revision surgery. Patients with normal alignment preoperatively did worse than those with abnormal alignment with patellar instability. Patients with grade two tibiofemoral arthritis, history of previous surgery did significantly worse with poorer functional outcome. Conclusion. Patellofemoral arthroplasty is reliable treatment option which improves patient function and quality of life with good survivorship in isolated patellofemoral arthritis in mid-term follow-up


Bone & Joint Open
Vol. 2, Issue 1 | Pages 58 - 65
22 Jan 2021
Karssiens TJ Gill JR Sunil Kumar KH Sjolin SU

Aims. The Mathys Affinis Short is the most frequently used stemless total shoulder prosthesis in the UK. The purpose of this prospective cohort study is to report the survivorship, clinical, and radiological outcomes of the first independent series of the Affinis Short prosthesis. Methods. From January 2011 to January 2019, a total of 141 Affinis Short prostheses were implanted in 127 patients by a single surgeon. Mean age at time of surgery was 68 (44 to 89). Minimum one year and maximum eight year follow-up (mean 3.7 years) was analyzed using the Oxford Shoulder Score (OSS) at latest follow-up. Kaplan-Meier survivorship analysis was performed with implant revision as the endpoint. Most recently performed radiographs were reviewed for component radiolucent lines (RLLs) and proximal humeral migration. Results. Five shoulders underwent revision surgery (3.5%); three for rotator cuff failure, one for infection, and one for component malposition. Survivorship of the implant was 95.4% (95% confidence interval 90.1% to 97.9%) at five and nine years. Mean OSS improved significantly compared to preoperative values from 19.0 (1 to 35) to 43.3 (7 to 48) (p < 0.001). Radiological analysis was undertaken for 99 shoulders. This revealed humeral RLLs in one case (1%), glenoid RLLs in 15 cases (15.2%), and radiological rotator cuff failure in 22 cases (22.2%). Conclusion. This prospective cohort study shows encouraging short- to mid-term survivorship and clinical and radiological results for the Mathys Affinis Short, Short Stem Total Shoulder Prosthesis. Level of Evidence: IV. Cite this article: Bone Jt Open 2021;2(1):58–65


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_7 | Pages 3 - 3
1 Jul 2022
Sheridan G Cassidy R McKee C Hughes I Hill J Beverland D
Full Access

Abstract. Introduction. With respect to survivorship following total knee arthroplasty (TKA), joint registries consistently demonstrate higher revision rates for both sexes in those less than 55 years. The current study analyses the survivorship of 500 cementless TKAs performed in this age group in a high-volume primary joint unit where cementless TKA has traditionally been used for the majority of patients. Methods. This was a retrospective review of 500 consecutive TKAs performed in patients under the age of 55 between March 1994 and April 2017. The primary outcome measure for the study was all-cause revision. Secondary outcome measures included clinical, functional and radiological outcomes. Results. The all-cause revision rate was 1.6% (n=8) at a median of 55.7 months. Four were revised for infection, 2 for stiffness, 1 for aseptic loosening of the tibial component and 1 patella was resurfaced for anterior knee pain. The aseptic revision rate was 0.8% (n=4). Twenty-seven (5.4%) patients underwent a manipulation under anaesthetic (MUA). Including those who underwent MUA, 6.8% (n=34) underwent other non-revision procedures. Conclusion. Survivorship in our unit in this young patient cohort was excellent with an aseptic revision rate of 0.8% at 59.7 months using a fully cementless construct. The MUA rate was higher than expected


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_11 | Pages 3 - 3
1 Nov 2022
Mohan R Staunton D Carter J Highcock A
Full Access

Abstract. Background and study aim. The UK National Joint Registry(NJR) has not reported total knee replacement (TKR)survivorship based on design philosophy alone, unlike its international counterparts. We report outcomes of implant survivorship based on design philosophy using data from NJR's 2020 annual report. Materials and methods. All TKR implants with an identifiable design philosophy from NJR data were included. Cumulative revision data for cruciate-retaining(CR), posterior stabilised(PS), mobile-bearing(MB) design philosophies was derived from merged NJR data. Cumulative revision data for individual brands of implants with the medial pivot(MP) philosophy were used to calculate overall survivorship for this design philosophy. The all-cause revision was used as the endpoint and calculated to 15 years follow-up with Kaplan-Meier curves. Results. 1,144,384 TKRs were included. CR is the most popular design philosophy (67.4%), followed by PS (23.1%), MB (6.9%) and least commonly MP (2.6%). MP and CR implants showed the best survivorship (95.7% and 95.6% respectively) at 15 years which is statistically significant at, and beyond, 10 years. Observed survivorship was lower at all time points with the PS and MB implants (94.5% for both designs at 15 years). Conclusions. While all design philosophies considered in this study survive well, CR and MP designs offer statistically superior survivorship at and beyond 10 years. MP design performs better than CR beyond 13 years yet, remain the least popular design philosophy used. Publishing data based on knee arthroplasty design philosophy would help surgeons when making decisions on implant choice


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_7 | Pages 31 - 31
1 Jul 2022
Lodge C Matar H Berber R Radford P Bloch B
Full Access

Abstract. Aims. Ceramic coatings in total knee arthroplasty have been introduced with the aim of reducing wear and consequently improving implant survivorship. We studied both cobalt-chrome-molybdenum and ceramic-coated components of the same implant design from a single centre to identify if the ceramic coating conferred any benefit at mid-term review. Patients and Methods. We identified 1641 Columbus TKAs (Aesculap AG, Tüttlingen, Germany) from a prospectively collected arthroplasty database. 983 were traditional CoCrMo and 659 had the AS ceramic coating. Patients were followed up until death or revision of the implant. Results. A slightly younger patient population was seen in the AS ceramic cohort which was statistically significant, mean 68.3 (p=<0.0001). There was no significant difference in implant survivorship between the CoCrMo femur and the ceramic coated femur at a mean of 9.2 years follow-up for the CoCrMo group and 5 years for the ceramic coated group (p=0.76). There was no reduction in the proportion of components revised for aseptic loosening or infection in the ceramic coated cohort. Conclusion. The reported benefits of ceramic coatings are note clearly demonstrated within our current cohort. All knee replacements within our cohort were performed by a user of both CoCrMo and AS and therefore implant familiarity does not explain the revision rate within the AS cohort. At mid-term follow-up, there was no benefit in terms of implant survivorship in using a ceramic coating


The Bone & Joint Journal
Vol. 101-B, Issue 11 | Pages 1356 - 1361
1 Nov 2019
Chalmers BP Mehrotra KG Sierra RJ Pagnano MW Taunton MJ Abdel MP

Aims. Knee osteonecrosis in advanced stages may lead to joint degeneration. Total knee arthroplasty (TKA) for osteonecrosis has traditionally been associated with suboptimal results. We analyzed outcomes of contemporary TKAs for osteonecrosis, with particular emphasis on: survivorship free from aseptic loosening, any revision, and any reoperation plus the clinical outcomes, complications, and radiological results. Patients and Methods. In total, 156 patients undergoing 167 primary TKAs performed for osteonecrosis between 2004 and 2014 at a single institution were reviewed. The mean age at index TKA was 61 years (14 to 93) and the mean body mass index (BMI) was 30 kg/m. 2. (18 to 51) The mean follow-up was six years (2 to 12). A total of 110 TKAs (66%) were performed for primary osteonecrosis and 57 TKAs (34%) for secondary osteonecrosis. Overall, 15 TKAs (9%) had tibial stems, while 12 TKAs (7%) had femoral stems. Posterior-stabilized designs were used in 147 TKAs (88%) of TKAs. Bivariate Cox regression analysis was conducted to identify risk factors for revision and reoperation. Results. Survivorship free from aseptic loosening, any revision, and any reoperation at ten years was 97% (95% confidence interval (CI) 93 to 100), 93% (95% CI 85 to 100), and 82% (95% CI 69 to 93), respectively. No factors, including age, sex, BMI, primary versus secondary osteonecrosis, stem utilization, and constraint, were identified as risk factors for reoperation. Four TKAs (2%) underwent revision, most commonly for tibial aseptic loosening (n = 2). Excluding revisions and reoperations, there was a total of 11 complications (7%), with the most common being a manipulation under anaesthesia (six TKAs, 4%). Mean Knee Society Scores (Knee component) significantly improved from 57 (32 to 87) preoperatively to 91 (49 to 100) postoperatively (p < 0.001). No unrevised TKAs had complete radiolucent lines or radiological evidence of loosening. Conclusion. Contemporary cemented TKAs with selective stem utilization for osteonecrosis resulted in durable survivorship, a low complication rate, and reliable improvement in clinical outcomes. Cite this article: Bone Joint J 2019;101-B:1356–1361


Aims. The use of high tibial osteotomy (HTO) to delay total knee arthroplasty (TKA) in young patients with osteoarthritis (OA) and constitutional deformity remains debated. The aim of this study was to compare the long-term outcomes of TKA after HTO compared to TKA without HTO, using the time from the index OA surgery as reference (HTO for the study group, TKA for the control group). Methods. This was a case-control study of consecutive patients receiving a posterior-stabilized TKA for OA between 1996 and 2010 with previous HTO. A total of 73 TKAs after HTO with minimum ten years’ follow-up were included. Cases were matched with a TKA without previous HTO for age at the time of the HTO. All revisions were recorded. Kaplan-Meier survivorship analysis was performed using revision of metal component as the endpoint. The Knee Society Score, range of motion, and patient satisfaction were assessed. Results. Mean follow-up was 13 years (SD 3) after TKA in both groups. The 20-year Kaplan-Meier survival estimate was 98.6% in TKA post-HTO group (HTO as timing reference) and 81.4% in control group (TKA as timing reference) (p = 0.030). There was no significant difference in clinical outcomes, radiological outcomes, and complications at the last follow-up. Conclusion. At the same delay from index surgery (HTO or TKA), a strategy of HTO followed by TKA had superior knee survivorship compared to early TKA at long term in young patients. Level of evidence: III. Cite this article: Bone Jt Open 2023;4(2):62–71


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_9 | Pages 19 - 19
16 May 2024
Clifton L Kingman A Rushton P Murty A Kakwani R Coorsh J Townshend D
Full Access

Introduction. We report the functional outcome and survivorship of the Hintegra Total Ankle Replacement (TAR), in consecutive cases by multiple surgeons in a single UK institution. Between 2010–2014 the Hintegra TAR held 7.1% UK market share and surgeons should be aware of failure mechanisms. Methods. We conducted a retrospective review of prospectively collected data for 70 consecutive Hintegra TAR cases in a single institution between 2010–2014. Data collected included patient demographics, complications, reoperations, patient reported outcome measures (PROMS: AOS, MOX-FQ, pain VAS) and patient satisfaction. Results. The 70 patients (54 male/ 16 female) had an average age of 69 (range 48–84 years). Mean follow up was 76 months (range 60–04), 10 patients died during the follow up. Implant survivorship was 81.4% at most recent follow up. The commonest radiographic finding was periprosthetic cysts (n=28, 40%), size range (7–40mm), location of cysts: isolated talus (n=14), isolated tibia (n=6), mixed (n=8). 10 failed TARs were revised to Inbone TAR at a mean of 48 months (range 9–69). 3 Failed TARs were revised to arthrodesis (2 tibiotalar fusions, 1 hindfoot nail). 11 patients required reoperation with implant retention: 8 periprosthetic cyst debridement and grafting at a mean of 61 months (range 27–91), 1 lateral gutter debridement and 1 periprosthetic fracture ORIF. PROMS data was available for all patients. Overall patients showed marked improvement in functional outcome scores between pre-operative and final follow up questionnaires. Mean pre-op AOS: 62, MOX-FQ: 68 and pain VAS: 67.5 with mean final follow up scores of: AOS: 35, MOX-FQ: 36 and pain VAS: 30. Conclusion. Our experience demonstrates improved PROMS following ankle arthroplasty for patients with a mean follow up of 6.4 years. Implant survivorship is similar to other TAR studies. We have identified a high incidence of periprosthetic cysts and would recommend ongoing surveillance of these patients


The Bone & Joint Journal
Vol. 101-B, Issue 6 | Pages 660 - 666
1 Jun 2019
Chalmers BP Limberg AK Athey AG Perry KI Pagnano MW Abdel MP

Aims. There is little literature about total knee arthroplasty (TKA) after distal femoral osteotomy (DFO). Consequently, the purpose of this study was to analyze the outcomes of TKA after DFO, with particular emphasis on: survivorship free from aseptic loosening, revision, or any re-operation; complications; radiological results; and clinical outcome. Patients and Methods. We retrospectively reviewed 29 patients (17 women, 12 men) from our total joint registry who had undergone 31 cemented TKAs after a DFO between 2000 and 2012. Their mean age at TKA was 51 years (22 to 76) and their mean body mass index 32 kg/m. 2. (20 to 45). The mean time between DFO and TKA was ten years (2 to 20). The mean follow-up from TKA was ten years (2 to 16). The prostheses were posterior-stabilized in 77%, varus-valgus constraint (VVC) in 13%, and cruciate-retaining in 10%. While no patient had metaphyseal fixation (e.g. cones or sleeves), 16% needed a femoral stem. Results. The ten-year survivorship was 95% with aseptic loosening as the endpoint, 88% with revision for any reason as the endpoint, and 81% with re-operation for any reason as the endpoint. Three TKAs were revised for instability (n = 2) and aseptic tibial loosening (n = 1). No femoral component was revised for aseptic loosening. Patients under the age of 50 years were at greater risk of revision for any reason (hazard ratio 7; p = 0.03). There were two additional re-operations (6%) and four complications (13%), including three manipulations under anaesthetic (MUA; 10%). The Knee Society scores improved from a mean of 50 preoperatively (32 to 68) to a mean of 93 postoperatively (76 to 100; p < 0.001). Conclusion. A cemented posterior-stabilized TKA has an 88% ten-year survivorship with revision for any reason as the endpoint. No femoral component was revised for aseptic loosening. Patients under the age of 50 years have a greater risk of revision. The clinical outcome was significantly improved but balancing the knee was challenging in 13% of TKAs requiring VVC. Overall, 10% of TKAs needed an MUA, and 6% of TKAs were revised for instability. Cite this article: Bone Joint J 2019;101-B:660–666


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_7 | Pages 2 - 2
1 Jul 2022
Mohan R Staunton DM Carter JR Highcock A
Full Access

Abstract. Introduction. The UK National Joint Registry(NJR) has not reported total knee replacement (TKR)survivorship based on design philosophy alone, unlike its international counterparts. We report outcomes of implant survivorship based on design philosophy using data from NJR's 2020 annual report. Methodology. All TKR implants with an identifiable design philosophy from NJR data were included. Cumulative revision data for cruciate-retaining(CR), posterior stabilised(PS), mobile-bearing(MB) design philosophies was derived from merged NJR data. Cumulative revision data for individual brands of implants with the medial pivot(MP) philosophy were used to calculate overall survivorship for this design philosophy. The all-cause revision was used as the endpoint and calculated to 15 years follow-up with Kaplan-Meier curves. Results. 1,144,384 TKRs were included. CR is the most popular design philosophy(67.4%), followed by PS(23.1%), MB(6.9%), and least commonly MP(2.6%). MP and CR implants showed the best survivorship(95.7% and 95.6% respectively) at 15 years which is statistically significant at, and beyond, 10 years. Observed survivorship was lower at all time points with the PS and MB implants(94.5% for both designs at 15 years). Conclusions. While all design philosophies considered in this study survive well, CR and MP designs offer statistically superior survivorship at and beyond 10 years. MP design performs better than CR beyond 13 years yet, remains the least popular design philosophy used. Publishing data based on knee arthroplasty design philosophy would help surgeons when making decisions on implant choice


The Bone & Joint Journal
Vol. 102-B, Issue 3 | Pages 319 - 328
1 Mar 2020
St Mart J de Steiger RN Cuthbert A Donnelly W

Aim. There has been a significant reduction in unicompartmental knee arthroplasty (UKA) procedures recorded in Australia. This follows several national joint registry studies documenting high UKA revision rates when compared to total knee arthroplasty (TKA). With the recent introduction of robotically assisted UKA procedures, it is hoped that outcomes improve. This study examines the cumulative revision rate of UKA procedures implanted with a newly introduced robotic system and compares the results to one of the best performing non-robotically assisted UKA prostheses, as well as all other non-robotically assisted UKA procedures. Methods. Data from the Australian Orthopaedic Association National Joint Arthroplasty Registry (AOANJRR) for all UKA procedures performed for osteoarthritis (OA) between 2015 and 2018 were analyzed. Procedures using the Restoris MCK UKA prosthesis implanted using the Mako Robotic-Arm Assisted System were compared to non-robotically assisted Zimmer Unicompartmental High Flex Knee System (ZUK) UKA, a commonly used UKA with previously reported good outcomes and to all other non-robotically assisted UKA procedures using Cox proportional hazard ratios (HRs) and Kaplan-Meier estimates of survivorship. Results. There was no difference in the rate of revision when the Mako-assisted Restoris UKA was compared to the ZUK UKA (zero to nine months: HR 1.14 (95% CI 0.71 to 1.83; p = 0.596) vs nine months and over: HR 0.66 (95% CI 0.42 to 1.02; p = 0.058)). The Mako-assisted Restoris had a significantly lower overall revision rate compared to the other types of non-robotically assisted procedures (HR 0.58 (95% confidence interval (CI) 0.42 to 0.79); p < 0.001) at three years. Revision for aseptic loosening was lower for the Mako-assisted Restoris compared to all other non-robotically assisted UKA (entire period: HR 0.34 (95% CI 0.17 to 0.65); p = 0.001), but not the ZUK prosthesis. However, revision for infection was significantly higher for the Mako-assisted Restoris compared to the two comparator groups (ZUK: entire period: HR 2.91 (95% CI 1.22 to 6.98; p = 0.016); other non-robotically assisted UKA: zero to three months: HR 5.57 (95% CI 2.17 to 14.31; p < 0.001)). Conclusion. This study reports comparable short-term survivorship for the Mako robotically assisted UKA compared to the ZUK UKA and improved survivorship compared to all other non-robotic UKA. These results justify the continued use and investigation of this procedure. However, the higher rate of early revision for infection for robotically assisted UKA requires further investigation. Cite this article: Bone Joint J 2020;102-B(3):319–328


Robotic assistance in knee arthroplasty has become increasingly popular due to improved accuracy of prosthetic implantation. However, literature on the mid-term outcomes is limited especially that of hand-held robotic-assisted devices. We present one of the longest follow-up series to date using this novel technology and discuss the learning curve for introducing robotic technology into our practice. The purpose of this single-surgeon study is to evaluate the survival, patient-reported outcomes and learning curve for handheld boundary-controlled robotic-assisted unicompartmental knee arthroplasties (HBRUKAs) at our hospital. This retrospective study evaluates 100 cases (94 Medial, 6 Lateral) performed by a single surgeon between October 2012 and July 2018. 52% were males, mean age was 64.5y (range 47.3y-85.2y) and mean BMI was 31.3 (range 21.8–43). Both inlay (40%) and onlay (60%) designs were implanted. Patients were followed up routinely at 1 and 5 years with Oxford Knee Scores (OKS) recorded. The learning curve was determined by tourniquet times. At a mean follow-up of 4.3 years (range 1.6y–7.3y), survivorship was 97%. There were three revisions: One case of aseptic loosening (1.5y), one case of deep-infection (3.8y) and one case of contralateral compartment osteoarthritis progression (5y). Mean 5-year OKS was 39.8. A 14.3% reduction in mean tourniquet times between the first 25 cases (105.5minutes) and subsequent cases (90.4minutes) was seen. This single-surgeon study showed good survivorship and patient-reported outcomes for HBRUKAs at our hospital. A learning curve of approximately 25 cases was shown, with significant decreases in tourniquet times with respect to increased surgeon experience


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_7 | Pages 20 - 20
1 Jul 2022
Chuntamongkol R Burt J Zaffar H Habbick T Picard F Clarke J Gee C
Full Access

Abstract. Introduction. There is a longstanding presumed association between obesity, complications, and revision surgery in primary knee arthroplasty. This has more recently been called into question, particularly in centres where a high volume of arthroplasty is performed. We investigated the correlation between Body Mass Index (BMI), mortality, and revision surgery. Method. This was a cohort study of at least 10 years following primary knee arthroplasty from a single high volume arthroplasty unit. Mortality and revision rates were collected from all patients who underwent primary knee arthroplasty between 2009 and 2010. Kaplan Meier analysis was performed. Results. There were 1161 female and 948 male patients with a mean age of 69 (21 to 97). All cause survivorship excluding mortality was 97.2% up to 13yrs with a minimum of 10 years. The revision rate in this series was 2.8% with no significant difference in revision rates after 10 year between patients with BMI above and below 40 (p=0.438). There was no significant difference in 10-year mortality between patients above and below a BMI of 40 (p=0.238). Conclusion. This study shows no significant difference in the long term survival of total knee replacement between patients with normal and high BMI. Careful consideration should be given before rationing surgery based on BMI alone


Aims. To establish the survivorship, function, and metal ion levels in an unselected series of metal-on-metal hip resurfacing arthroplasties (HRAs) performed by a non-designer surgeon. Methods. We reviewed 105 consecutive HRAs in 83 patients, performed by a single surgeon, at a mean follow-up of 14.9 years (9.3 to 19.1). The cohort included 45 male and 38 female patients, with a mean age of 49.5 years (SD 12.5). Results. At the time of review 13 patients with 15 hips had died from causes unrelated to the hip operation, and 14 hips had undergone revision surgery, giving an overall survival rate of rate of 86.7% (95% confidence interval (CI) 84.2 to 89.1). The survival rate in men was 97.7% (95% CI 96.3 to 98.9) and in women was 73.4% (95% CI 70.6 to 75.1). The median head size of the failed group was 42 mm (interquartile range (IQR) 42 to 44), and in the surviving group was 50 mm (IQR 46 to 50). In all, 13 of the 14 revised hips had a femoral component measuring ≤ 46 mm. The mean blood levels of cobalt and chromium ions were 26.6 nmol/l (SD 24.5) and 30.6 nmol/l (SD 15.3), respectively. No metal ion levels exceeded the safe limit. The mean Oxford Hip Score was 41.5 (SD 8.9) and Harris Hip Score was 89.9 (14.8). In the surviving group, four patients had radiolucent lines around the stem of the femoral component, and one had lysis around the acetabular component; eight hips demonstrated heterotopic ossification. Conclusion. Our results confirm the existing understanding that HRA provides good long-term survival and function in patients with adequate-sized femoral heads. This is evidenced by a 97.7% survival rate among men (larger heads) in our series at a mean follow-up of 14.9 years. Failure is closely related to head sizes ≤ 46 cm. Cite this article: Bone Jt Open 2022;3(1):68–76


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_13 | Pages 32 - 32
7 Aug 2023
Nicholls K Petsiou D Wilcocks K Shean K Anderson J Vachtsevanos L
Full Access

Abstract. Introduction. Surgery in patients with high body mass index (BMI) is more technically challenging and associated with increased complications post-operatively. Inferior clinical and functional mid-term results for high BMI patients undergoing high tibial osteotomy (HTO) relative to normal weight patients have been reported. This study discusses the clinical, radiological and functional outcomes of HTO surgery in patients with a high BMI. Method. This is a retrospective study on patients undergoing HTO surgery using the Tomofix anatomical MHT plate between 2017 and 2022, with follow-up period of up to 5 years. The cohort was divided: non-obese (BMI <30 kg/m2) and obese (BMI>30 kg/m2). Pre and post operative functional scores were collected: Oxford Knee Score (OKS), EuroQol-5D and Tegner. Complications, plate survivorship and Mikulicz point recorded. Results. 32 HTO procedures; 19 patients BMI <30 (average 27.0) and 14 patients BMI >30 (average 36.1). In BMI<30 cohort, one readmission for investigation of venous thromboembolism, doppler negative; two complications: hinge fracture and stitch abscess. The five year survivorship of the plate was 100%. In BMI>30 cohort, one readmission for pulmonary embolism; one complication: hinge fracture. The 5 year survivorship of the plate was 93%, 1 conversion to unicompartmental knee replacement. The average OKS improvement was 17 and 18 for BMI <30 and >30 respectively. Mikulicz point change was identical. Conclusion. The Tomofix anatomical MHT plate achieves good outcomes and minimal complications irrespective of BMI. Reduced plate survivorship, thus earlier conversion may be required in the obese, however higher cohort numbers are needed to confirm this


The Bone & Joint Journal
Vol. 104-B, Issue 7 | Pages 767 - 774
1 Jul 2022
Nakashima Y Ishibashi S Kitamura K Yamate S Motomura G Hamai S Ikemura S Fujii M

Aims. Although periacetabular osteotomies are widely used for the treatment of symptomatic dysplastic hips, long-term surgical outcomes and patient-reported outcome measures (PROMs) are still unclear. Accordingly, we assessed hip survival and PROMs at 20 years after transpositional osteotomy of the acetabulum (TOA). Methods. A total of 172 hips in 159 patients who underwent TOA were followed up at a mean of 21.02 years (16.6 to 24.6) postoperatively. Kaplan-Meier analysis was used to assess survivorship with an endpoint of total hip arthroplasty (THA). PROMs included the visual analogue scale (VAS) Satisfaction, VAS Pain, Oxford Hip Score (OHS), and Forgotten Joint Score-12 (FJS-12). Thresholds for favourable outcomes for OHS (≥ 42) and FJS-12 (≥ 51) were obtained using the receiver operating characteristic curve with VAS Satisfaction ≥ 50 and VAS Pain < 20 as anchors. Results. THA was performed on 37 hips (21.5%) by the latest follow-up. Kaplan-Meier analysis indicated that the hip survival rate at 20 years was 79.7% (95% confidence interval (CI) 73.7 to 86.3). Multivariate analysis showed that preoperative Tönnis grade significantly influenced hip survival. Tönnis grades 0, 1, and 2 were associated with 20-year survival rates of 93.3% (95% CI 84.8 to 100), 86.7% (95% CI 79.8 to 94.3), and 54.8% (95% CI 41.5 to 72.3), respectively. More than 60% of the patients exhibited favourable PROMs. An advanced Tönnis grade at the latest follow-up and a higher BMI were both significantly associated with unfavourable OHS, but not with other PROMs. Conclusion. This study demonstrated the durability of TOA for hips with Tönnis grades 0 to 1 at 20 years. While the presence of advanced osteoarthritis and higher BMI was associated with lower hip functions (OHS), it was not necessarily associated with worse patient satisfaction and joint awareness. Cite this article: Bone Joint J 2022;104-B(7):767–774


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_6 | Pages 3 - 3
1 Jun 2022
Chuntamongkol R Burt J Zaffar H Habbick T Picard F Clarke J Gee C
Full Access

There is a longstanding presumed association between obesity, complications, and revision surgery in primary knee arthroplasty. This has more recently been called into question, particularly in centres where a high volume of arthroplasty is performed. We investigated the correlation between Body Mass Index (BMI), mortality, and revision surgery. This was a cohort study of at least 10 years following primary knee arthroplasty from a single high volume arthroplasty unit. Mortality and revision rates were collected from all patients who underwent primary knee arthroplasty between 2009 and 2010. Kaplan Meier analysis was performed. There were 1161 female and 948 male patients with a mean age of 69 (21 to 97). All cause survivorship excluding mortality was 97.2% up to 13yrs with a minimum of 10 years. The revision rate in this series was 2.8% with no significant difference in revision rates after 10 year between patients with BMI above and below 40 (p=0.438). There was no significant difference in 10–year mortality between patients above and below a BMI of 40 (p=0.238). This study shows no significant difference in the long term survival of total knee replacement between patients with normal and high BMI. Careful consideration should be given before rationing surgery based on BMI alone


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_13 | Pages 69 - 69
7 Aug 2023
Kumar A Stevens S Jonas S White S Agarwal S
Full Access

Abstract. Introduction. Isolated patellofemoral joint(PFJ) osteoarthritis affects approximately 10% of patients aged over 40 years and treatment remains controversial. Our aim was to evaluate long term functional and radiological outcomes following PFJ arthorplasty with the Femoro Patella Vialli (FPV) prosthesis as this evidence is lacking in literature. Methodology. A retrospective review of prospectively collected PROMS in patients undergoing Patellofemoral arthroplasty. Single centre trial. Between 2004 and 2008, 101 FPV patellofemoral arthroplasties were performed in 80 patients with isolated patellofemoral joint osteoarthritis. Data was collected as a part of routine follow-up for up to 6 years and additional long term data was collected at 16 years. Results. At 6 year follow up the mean OKS was 29 and by 16 year follow up it was 26 which was not a statistically significant drop. 22 patients (29 knees) had died, 32 (32%) had been revised, 25 to total knee replacement using primary arthroplasty components. Mean OKS in the revised group was 27 which was not a statistically significant difference when compared to the unrevised group. Mean time to revision was 4 years. The cumulative survival analysis of the FPV implant was 76% at 5 years, 64% at 10 years. Conclusion. Our findings suggest the FPV patellofemoral prosthesis provides good pain relief and clinical outcomes however, the survivorship for this particular implant maybe lower as compared to the available literature. Patient reported outcomes are maintained over the implant life and are no worse once revised implying a staged approach to arthroplasty is reasonable


Bone & Joint Open
Vol. 3, Issue 3 | Pages 182 - 188
1 Mar 2022
Boktor J Badurudeen A Rijab Agha M Lewis PM Roberts G Hills R Johansen A White S

Aims. In UK there are around 76,000 hip fractures occur each year 10% to 15% of which are undisplaced intracapsular. There is considerable debate whether internal fixation is the most appropriate treatment for undisplaced fractures in older patients. This study describes cannulated hip screws survivorship analysis for patients aged ≥ 60 years with undisplaced intra-capsular fractures. Methods. This was a retrospective cohort study of consecutive patients aged ≥ 60 years who had cannulated screws fixation for Garden I and II fractures in a teaching hospital between March 2013 and March 2016. The primary outcome was further same-side hip surgery. Descriptive statistics were used and Kaplan-Meier estimates calculated for implant survival. Results. A total of 114 operations were performed on 112 patients with a mean age of 80.2 years (SD 8.9). The 30-day and one-year mortality were 1% (n = 1) and 13% (n = 15), respectively. Median follow-up was 6.6 years (interquartile range 6.0 to 7.3). Kaplan-Meier estimates showed a survivorship of 95% at one year and 90% at five years (95% confidence interval 84% to 95%) for cannulated screws. Nine patients underwent further hip surgery: four revision to total hip arthroplasty, one revision to hemiarthroplasty, three removals of screws, and one haematoma washout. Posterior tilt was assessable in 106 patients; subsequent surgery was required in two of the six patients identified with a posterior angle > 20° (p = 0.035 vs angle < 20°). Of the 100 patients with angle < 20°, five-year survivorship was 91%, with seven patients requiring further surgery. Conclusion. This study of cannulated hip screw fixation for undisplaced fractures in patients aged ≥ 60 years reveals a construct survivorship without further operation of 90% at five years. Cannulated screws can be considered a safe reliable treatment option for Garden I and II fractures. Caution should be taken if posterior tilt angle on lateral view exceeds 20°, due to a higher failure rate and reoperation, and considered for similar management to Garden III and IV injuries. Cite this article: Bone Jt Open 2022;3(3):182–188


The Bone & Joint Journal
Vol. 101-B, Issue 6_Supple_B | Pages 68 - 76
1 Jun 2019
Jones CW Choi DS Sun P Chiu Y Lipman JD Lyman S Bostrom MPG Sculco PK

Aims. Custom flange acetabular components (CFACs) are a patient-specific option for addressing large acetabular defects at revision total hip arthroplasty (THA), but patient and implant characteristics that affect survivorship remain unknown. This study aimed to identify patient and design factors related to survivorship. Patients and Methods. A retrospective review of 91 patients who underwent revision THA using 96 CFACs was undertaken, comparing features between radiologically failed and successful cases. Patient characteristics (demographic, clinical, and radiological) and implant features (design characteristics and intraoperative features) were collected. There were 74 women and 22 men; their mean age was 62 years (31 to 85). The mean follow-up was 24.9 months (. sd. 27.6; 0 to 116). Two sets of statistical analyses were performed: 1) univariate analyses (Pearson’s chi-squared and independent-samples Student’s t-tests) for each feature; and 2) bivariable logistic regressions using features identified from a random forest analysis. Results. Radiological failure and revision rates were 23% and 12.5%, respectively. Revisions were undertaken at a mean of 25.1 months (. sd. 26.4) postoperatively. Patients with radiological failure were younger at the time of the initial procedure, were less likely to have a diagnosis of primary osteoarthritis (OA), were more likely to have had ischial screws in previous surgery, had fewer ischial screw holes in their CFAC design, and had more proximal ischial fixation. Random forest analysis identified the age of the patient and the number of locking and non-locking screws used for inclusion in subsequent bivariable logistic regression, but only age (odds ratio 0.93 per year) was found to be significant. Conclusion. We identified both patient and design features predictive of CFAC survivorship. We found a higher rate of failure in younger patients, those whose primary diagnosis was not OA, and those with more proximal ischial fixation or fewer ischial fixation options. Cite this article: Bone Joint J 2019;101-B(6 Supple B):68–76


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_11 | Pages 7 - 7
1 Oct 2019
Catani F Ensini A Zambianchi F Illuminati A Matveitchouk N
Full Access

Introduction. Robotic technology has been applied to unicompartmental knee arthroplasty (UKA) in order to improve surgical precision in prosthetic component placement, restore knee anatomic surfaces, and provide a more physiologic ligament tensioning throughout the knee range of motion. Recent literature has demonstrated high reliability of robotic-arm assisted UKA in component placement and executing a soft-tissue tensioning plan, with excellent short-term survivorship. Few studies have investigated survivorship and patients' satisfaction at longer follow-ups. Therefore, the purpose of the present study was to determine the survivorship, clinical results and patients' satisfaction of robotic-arm assisted UKAs at a mid-term follow-up, with a minimum of 5 years of follow-up. Methods. The present retrospective study includes 252 patients (260 knees) who underwent robotic-arm assisted fixed bearing metal backed UKAs at a single centre between April 2011 and July 2013. The mean age at surgery was 66.2 years (SD 8.6). Post-operatively, patients were administered the Forgotten Joint Score-12 (FJS) and asked about their satisfaction level after knee surgery (grade from 1 to 5). Post-operative complications were recorded. Failure mechanisms, revisions and reoperations were also assessed. Kaplan-Meier survival curves were calculated, considering reoperation for all causes and revision as the events of interest. Results. A total of 223 patients (231 robotic-arm assisted UKAs) were assessed at a mean follow-up of 5.8 years post-operatively (88.5% follow-up rate, min. 60 months, max. 87 months). In 219 cases, a medial robotic-arm assisted UKA was implanted, in 12 cases a lateral implant was performed. Five medial robotic-arm assisted UKAs were revised, resulting in a survivorship of 98% (C.I. 96.0%–99.1%). One case underwent revision for prosthetic joint infection, one for tibial aseptic loosening, one for post-traumatic tibial plateau fracture, and two for unexplained pain. No lateral robotic-arm assisted UKAs were revised, resulting in a survivorship of 100%. On average, the FJS and the satisfaction level resulted 75.6 (SD 26.1) and 4.2 (SD 1.0) in medial UKAs, and 81.7 (SD 15.3) and 4.4 (SD 0.8) in lateral UKAs, respectively. In medial UKAs 83% of the examined cohort reported good/excellent FJS outcomes, while 92% of the lateral UKA patients had good/excellent FJS results. In medial UKAs, male patients resulted to have better FJS (p<0.01) and higher satisfaction level (p<0.03) compared to female patients, while no outcome differences were reported in patients with BMI>30 and among different age groups. Given the small number of lateral UKAs included in the present patients' cohort, no statistical analysis was performed on this group. Conclusion. In the present study, survivorship and clinical outcomes of a large cohort of 223 patients undergoing medial and lateral robotic-arm assisted UKAs were assessed at a mean of 5.8 years of follow-up. The overall survivorship was found to be 98%, with unexplained knee pain as the most common reason for UKA revision. The present study shows that robotic-arm assisted UKA patients had lower revision rates for aseptic loosening and osteoarthritis progression compared to conventional UKA at mid-term follow-up, as reported in the literature. The good post-operative clinical scores highlight the efficacy of robotic-arm assisted UKA in restoring knee function and relieving pain. For figures, tables, or references, please contact authors directly


The Lubinus SP II is an anatomical femoral stem with high survivorship levels notably described in the Swedish Arthroplasty Register. As the clinical and economic burden of revision total hip arthroplasty (THA) and periprosthetic fracture (PPF) continues to increase, it has been suggested that use of anatomical stems may facilitate more uniform cement mantles and improve implant survival. The primary aim of this study was to determine the long-term survivorship and PPF rate of the Lubinus SP II 150mm stem in a single UK centre. Between January 2007 and April 2012, 1000 consecutive THAs were performed using the Lubinus SP II femoral stem in our institution. Patient demographics and operative details were collected in a prospective arthroplasty database. Patient records and national radiographic archives were then reviewed at a mean of 12.3 years (SD 1.3) following surgery to identify occurrence of subsequent revision surgery, dislocation or periprosthetic fracture. Mean patient age at surgery was 69.3 years (SD 10.1, 24–93 years). There were 634 women (63%). Osteoarthritis was the operative indication in 974 patients (97%). There were 13 revisions in total (4 for recurrent dislocation, 3 for infection, 6 for acetabular loosening) and 16 dislocations (1.6%). Stem survivorship at 10 years was 99.6% (95 % confidence interval [CI], 99.5%–99.7%) and at 15 years was 98.8% (98.7%–98.9%). The 15-year stem survival for aseptic loosening was 100%. Analysis of all cause THA failure demonstrated a survivorship of 99.1% (99.0%–99.3%) at 10 years and 98.2% (98.1%–98.3%) at 15 years. There were 4 periprosthetic fractures in total (0.4%) at mean 12.3 year follow-up. The Lubinus SP II stem demonstrated excellent survivorship, low dislocation rates and negligible PPF rates up to 15 years following primary THA. Use of anatomical stems such as the Lubinus SPII would appear to be a wise clinical and economic investment for patients and healthcare systems alike


The Bone & Joint Journal
Vol. 103-B, Issue 6 Supple A | Pages 32 - 37
1 Jun 2021
Restrepo S Smith EB Hozack WJ

Aims. Cementless total knee arthroplasty (TKA) offers the potential for strong biological fixation compared with cemented TKA where fixation is achieved by the mechanical integration of the cement. Few mid-term results are available for newer cementless TKA designs, which have used additive manufacturing (3D printing). The aim of this study was to present mid-term clinical outcomes and implant survivorship of the cementless Stryker Triathlon Tritanium TKA. Methods. This was a single institution registry review of prospectively gathered data from 341 cementless Triathlon Tritanium TKAs at four to 6.8 years follow-up. Outcomes were determined by comparing pre- and postoperative Knee Injury and Osteoarthritis Outcome Score for Joint Replacement (KOOS JR) scores, and pre- and postoperative 12-item Veterans RAND/Short Form Health Survey (VR/SF-12) scores. Aseptic loosening and revision for any reason were the endpoints which were used to determine survivorship at five years. Results. At mid-term follow-up, the mean KOOS JR score improved significantly from 33.14 (0 t0 85, standard deviation (SD) 21.88) preoperatively to 84.12 (15.94 to 100, SD 20.51) postoperatively (p < 0.001), the mean VR/SF-12 scores improved significantly from physical health (PH), 31.21 (SD 5.32; 23.99 to 56.77) preoperatively to 42.62 (SD 10.72; 19.38 to 56.82) postoperatively (p < 0.001) and the mental health (MH), 38.15 (SD 8.17; 19.06 to 60.75) preoperatively to 55.09 (SD 9.64; 19.06 to 66.98) postoperatively (p < 0.001). A total of 11 revisions were undertaken, with an overall revision rate of 2.94%, including five for periprosthetic joint infection (1.34%), three for loosening (0.80%), two for instability (0.53%), and one for pain (0.27%). The overall survivorship was 97.06% and survivorship for aseptic loosening as the endpoint was 98.40%, with a 99.5% survivorship of the 3D-printed tibial component. Conclusion. This 3D-printed cementless total knee system shows excellent survivorship at mid-term follow-up. This design and the ability to obtain cementless fixation offers promise for excellent long-term durability. Cite this article: Bone Joint J 2021;103-B(6 Supple A):32–37


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_8 | Pages 25 - 25
1 Aug 2020
Salimian A Howatt J Dervin G Kim P
Full Access

The Oxford mobile bearing knee prosthesis (Zimmer Biomet Inc, Warsaw, Ind) is considered a good treatment option for isolated medial compartment knee arthrosis. From February 2001 until August 2016, 1719 primary Oxford medial unicompartmental knee replacement procedures were completed at our center by a group of seven surgeons. We undertook this study to examine the long-term survivorship of the Oxford unicompartmental knee replacement looking at survivorship and reasons for failure. A retrospective consecutive case series review was completed, and all revisions and re-operations were identified. Conversion to total knee replacement (TKA) was considered a failure. Kaplan-Meier survival analysis was used to calculate the 15-year survivorship of the group overall. We specifically looked at age, gender, BMI and surgeon caseload in addition to the reasons for failure. A statistical analysis was performed and differences in survivorship were compared for the variables listed. A logistic cox regression was performed to explore predictors of revision. Overall 15-year survivorship was 89.9%. Female survivorship of 88.1% was statistically worse than the male group at 91.8% (p=0.018). Younger patients (75yrs of age (p= 0.036). There was a large range in surgical case load by individual surgeons (range 17–570 knees). There were no statistically significant differences in age, BMI, or gender when comparing the individual surgeon groups. There was a large range in 15-year survivorship between individual surgeons (range 78.3% – 95%). Overall the most common reason for revision was due to wear of the unreplaced portion of the knee (lateral and/or patella-femoral joint) followed by aseptic loosening, polyethylene dislocation, infection or persistent pain. The 15-year survivorship results of the Oxford medial unicompartmental knee replacement at our center compares favourably to other published series and large registry data series. We found a reduction in survivorship in female patients and younger patients (< 5 5yrs). There were also significant differences in survivorship based on the individual surgeon. A more selective patient approach yielded the best long-term survivorship and equivalent to that of total knee replacement. We therefore suggest using a more selective approach when choosing patients for a medial unicompartmental knee replacement with the Oxford mobile bearing prosthesis in order to enhance long-term survivorship


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_11 | Pages 63 - 63
1 Oct 2019
Berend KR Crawford DA Adams JB Lombardi AV
Full Access

Introduction. Patients are often cautioned against a high level of activity following knee arthroplasty. The purpose of this study is to report on implant survivorship and outcomes of high activity patients compared to low activity patients after TKA. Methods. We identified 1611 patients (2038 knees) who underwent TKA with 5-year minimum follow-up. Patients were divided in two groups: Low activity (LA) (UCLA ≤5) and high activity (HA) (UCLA ≥ 6). Pre-and postoperative ROM, Knee Society scores, complications and reoperations were evaluated. Results. Mean follow-up was 11.4 years (range, 5.1 to 15.9 years). The HA group had significantly more male patients, were younger, lower BMI and higher functional scores pre-operatively. HA group had significantly higher improvements in Knee society scores and pain post-operatively. Revisions were performed in 4% of the LA group and 1.7% knees of the HA group (p=0.003). The all cause 12-year survivorship was 98% for the HA group and 95.3% to for the LA group (p=0.003). The aseptic 12-year survivorship was 98.4% for the HA group and 96.3% for the LA group (p=0.02). Conclusions. Highly active patients had increased survivorship at 5-year minimum follow-up compared to lower activity patients after TKA. For figures, tables, or references, please contact authors directly


The Bone & Joint Journal
Vol. 105-B, Issue 7 | Pages 768 - 774
1 Jul 2023
Wooster BM Kennedy NI Dugdale EM Sierra RJ Perry KI Berry DJ Abdel MP

Aims. Contemporary outcomes of primary total hip arthroplasties (THAs) with highly cross-linked polyethylene (HXLPE) liners in patients with inflammatory arthritis have not been well studied. This study examined the implant survivorship, complications, radiological results, and clinical outcomes of THA in patients with inflammatory arthritis. Methods. We identified 418 hips (350 patients) with a primary diagnosis of inflammatory arthritis who underwent primary THA with HXLPE liners from January 2000 to December 2017. Of these hips, 68% had rheumatoid arthritis (n = 286), 13% ankylosing spondylitis (n = 53), 7% juvenile rheumatoid arthritis (n = 29), 6% psoriatic arthritis (n = 24), 5% systemic lupus erythematosus (n = 23), and 1% scleroderma (n = 3). Mean age was 58 years (SD 14.8), 66.3% were female (n = 277), and mean BMI was 29 kg/m. 2. (SD 7). Uncemented femoral components were used in 77% of cases (n = 320). Uncemented acetabular components were used in all patients. Competing risk analysis was used accounting for death. Mean follow-up was 4.5 years (2 to 18). Results. The ten-year cumulative incidence of any revision was 3%, and was highest in psoriatic arthritis patients (16%). The most common indications for the 15 revisions were dislocations (n = 8) and periprosthetic joint infections (PJI; n = 4, all on disease-modifying antirheumatic drugs (DMARDs)). The ten-year cumulative incidence of reoperation was 6.1%, with the most common indications being wound infections (six cases, four on DMARDs) and postoperative periprosthetic femur fractures (two cases, both uncemented femoral components). The ten-year cumulative incidence of complications not requiring reoperation was 13.1%, with the most common being intraoperative periprosthetic femur fracture (15 cases, 14 uncemented femoral components; p = 0.13). Radiological evidence of early femoral component subsidence was observed in six cases (all uncemented). Only one femoral component ultimately developed aseptic loosening. Harris Hip Scores substantially improved (p < 0.001). Conclusion. Contemporary primary THAs with HXLPE in patients with inflammatory arthritis had excellent survivorship and good functional outcomes regardless of fixation method. Dislocation, PJI, and periprosthetic fracture were the most common complications in this cohort with inflammatory arthritis. Cite this article: Bone Joint J 2023;105-B(7):768–774


The Bone & Joint Journal
Vol. 100-B, Issue 10 | Pages 1320 - 1329
1 Oct 2018
Metcalfe D Peterson N Wilkinson JM Perry DC

Aims. The aim of this study was to describe temporal trends and survivorship of total hip arthroplasty (THA) in very young patients, aged ≤ 20 years. Patients and Methods. A descriptive observational study was undertaken using data from the National Joint Registry (NJR) for England, Wales, Northern Ireland and the Isle of Man between April 2003 and March 2017. All patients aged ≤ 20 years at the time of THA were included and the primary outcome was revision surgery. Descriptive statistics were used to summarize the data and Kaplan–Meier estimates calculated for the cumulative implant survival. Results. A total of 769 THAs were performed in 703 patients. The median follow-up was 5.1 years (interquartile range (IQR) 2.6 to 7.8). Eight patients died and 35 THAs were revised. The use of metal-on-metal (MoM) bearings and resurfacing procedures declined after 2008. The most frequently recorded indications for revision were loosening (20%) and infection (20%), although the absolute risk of these events occurring was low (0.9%). Factors associated with lower implant survival were MoM and metal-on-polyethylene (MoP) bearings and resurfacing arthroplasty (vs ceramic-on-polyethylene (CoP) and ceramic-on-ceramic (CoC) bearings, p = 0.002), and operations performed by surgeons who undertook few THAs in this age group as recorded in the NJR (vs those with five or more recorded operations, p = 0.030). Kaplan–Meier estimates showed 96% (95% confidence interval (CI) 94% to 98%) survivorship of implants at five years. Conclusion. Within the NJR, the overall survival for very young patients undergoing THA exceeded 96% during the first five postoperative years. In the absence of studies that can better account for differences in the characteristics of the patients, surgeons should consider the association between early revision and the type of implant, the number of THAs performed in these patients, and the bearing surface when performing THA in very young patients. Cite this article: Bone Joint J 2018;100-B:1320–9


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_7 | Pages 9 - 9
1 May 2016
Adravanti P Guggi T D'Anchise R Dwyer K Lesko J Kape J
Full Access

INTRODUCTION. There is ongoing debate about the possible advantages of unicompartmental (UNI) knee replacement versus total knee replacement (TKR), such as for young, active patients. The purpose of this study was to investigate functional, radiographic, and device survivorship outcomes of UNI knee replacement with a newer generation UNI through 2-years post-op. METHODS. A retrospective review of 188 cemented, fixed bearing unicompartmental (UNI) knee replacements implanted between January 2009 and June 2012 at 3 centers. The purpose of this study was to evaluate the survivorship, reasons for revision, radiographic and clinical results. A chart review was performed to collect demographics, operative details, American Knee Society (AKS) scores and adverse events (AE) through 2-years post-op. Kaplan-Meier (KM) device survivorship rates for the partial knee construct were estimated for post-op years in which at least 40 subjects had later follow-up. The definition of revision was the removal of any component for any reason, and device survivorship was the lack of revision. The time variable was the time to revision if the knee had been revised, or the time to last clinical follow-up or death if the knee had not been revised. The average follow-up was 2.03 years (SD=0.4). The mean age was 64 years (SD=10.5), 56% of the patients were 65 years or younger, mean BMI was 27.5 kg/m2 (SD=4.9), 60% of patients were women, and 89% had a diagnosis of OA (9.6% had AVN). Data were collected through April 2015. RESULTS. The KM device survivorship was 98.7% at 2 years (95% CI: 94.8–99.7%) (Figure 1). There were 3 revisions, 2 of which were prior to 2 years post-op (Figure 2) Overall, there were 23 operative site adverse events, including the 3 revisions. The most common AE was arthralgia (4.3%). There were no observations of lucencies, osteolysis, stress shielding, or femoral notching. At 2-years post-op the average AKS score was 89.9 points (N= 138, SD=11); 84% were in the good to excellent range. The average improvement from pre-op baseline at 2-years was 37.4 (N=117, SD=18). The average improvement in pain was 30 points (N=124, SD=15) on a 0–50 point scale, with 70% having no pain and 20% having mild pain at 2-years. Preoperatively, the average flexion was 118 degrees (N=152, SD=12.7o), which improved to 126 degrees (N=148, SD=9.4 o) at 2-years; average change from pre-op was 7.1 degrees (N=136, SD=12.2 o). Preoperatively, the average extension was 1.9 degrees (N=152, SD=3.6 o) which improved to 0.5 degrees (N=148, SD=1.6 o) at 2-years; average change from pre-op was a 1.4 degree improvement (N=136, SD=3.6 o). DISCUSSION. Overall results demonstrated excellent 2 year survivorship for this newer generation UNI, consistent with published national registry results for the class of UNIs. The clinical results demonstrated excellent pain relief and improvements in motion compared to preoperative. It will be of interest to investigate longer term outcomes of UNI knee replacement in a larger patient population, with a focus on younger, more active patients (younger than 60), perhaps with an emphasis on the quality of life


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_14 | Pages 52 - 52
1 Nov 2021
Nakashima Y Ishibashi S Kitamura K Yamate S Motomura G Hamai S Ikemura S Fujii M Yamaguchi R
Full Access

Although periacetabular osteotomies are widely used for the treatment of symptomatic acetabular dysplasia, the surgical outcomes after long term follow-up are still limited. Thus, we assessed hip survival and patient-reported outcomes (PROMs) at 20 years after the transposition osteotomy of acetabulum (TOA). Among 260 hips in 238 patients treated with TOA, 172 hips in 160 patients were evaluated at average 20.8 years, excluding patients who died or lost to follow-up. Kaplan-Meier analysis was used to assess survivorship with an end-point of THA. PROMs were evaluated using the VAS satisfaction, VAS pain, Oxford hip score (OHS), and Forgotten joint score (FJS). The thresholds of favorable outcomes of FJS and OHS were obtained using the receiver-operating characteristic curve with VAS satisfaction ≥ 50 and VAS pain < 20 as anchors. Thirty-three hips (19.2%) underwent THA at average 13.3 years after TOA. Kaplan-Meier analysis revealed hip survival rate at 20 years was 79.7%. Multivariate analysis showed the preoperative Tönnis grade significantly influenced hip survival. Survival rates with Tönnis grade 0, grade 1, and grade 2 were 93.3%, 86.7%, and 54.8% at 20 years, respectively. More than 60% of the patients showed favorable PROMs (VAS satisfaction ≥ 50, VAS pain < 20, OHS ≥ 42, FJS ≥ 51). Advanced Tönnis grade at the latest follow-up and higher BMI were significantly associated with unfavorable OHS, but not with other PROMs. This study demonstrated the durability of TOA for hips with Tönnis grade 0–1 and favorable satisfaction in majority of the patients at 20 years after surgery. Current presence of advanced osteoarthritis is associated with the lower hip function (OHS), but not necessarily associated with subjective pain and satisfaction. Higher BMI also showed a negative impact on postoperative function


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_4 | Pages 46 - 46
1 Apr 2019
Schroeder L Neginhal V Kurtz WB
Full Access

Background. In this study, we assessed implant survivorship, patient satisfaction, and patient-reported functional outcomes at two years for patients implanted with a customized, posterior stabilized knee replacement system. Methods. Ninety-three patients (100 knees) with the customized PS TKR were enrolled at two centers. Patients’ length of hospitalization and preoperative pain intensity were assessed. At a single time point follow-up, we assessed patient reported outcomes utilizing the KOOS Jr., satisfaction rates, implant survivorship, patients’ perception of their knee and their overall preference between the two knees, if they had their contralateral knee replaced with an off-the-shelf (OTS) implant. Results. At an average of 1.9-years implant survivorship was found to be 100%. From pre-op until time of follow-up, we observed an average decrease of 5.4 on the numeric pain rating scale. Satisfaction rate was found to be high with 90% of patients being satisfied or very satisfied and 88% of patients reporting a “natural” perception of their knee some or all the time. Patients with bilateral implants mostly (12/15) stated that they preferred their customized implant over the standard TKR. The evaluation of KOOS Jr. showed an average score of 90 at the time of the follow up. Conclusion. Based on our results, we believe that the customized PS implant provides patients with excellent outcomes post-surgery. Moreover, a subset of patients with an OTS implant in one knee and a customized PS implant in the other, we observed a trend in patients preferring the customized PS device over their OTS counterparts


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_6 | Pages 60 - 60
1 Mar 2017
van der List J Pearle A Carroll K Coon T Borus T Roche M
Full Access

INTRODUCTION. Successful clinical outcomes following unicompartmental knee arthroplasty (UKA) depend on component positioning, soft tissue balance and lower limb alignment, all of which can be difficult to achieve using manual instrumentation. A new robotic-guided technology has been shown to improve postoperative implant positioning and lower limb alignment in UKA but so far no studies have reported clinical results of robotic-assisted medial UKA. Goal of this study therefore was to assess outcomes of robotic-assisted medial UKA in a large cohort of patients at short-term follow-up. METHODS. This multicenter study with IRB approval examines the survivorship and satisfaction of this robotic-assisted procedure coupled with an anatomically designed UKA implant at a minimum of two-year follow-up. A total of 1007 patients (1135 knees) underwent robotic-assisted surgery for a medial UKA from six surgeons at separate institutions in the United States. All patients received a fixed-bearing metal backed onlay implant as the tibial component between March 2009 and December 2011 (Figure 1). Each patient was contacted at minimum two-year follow-up and asked a series of five questions to determine implant survivorship and patient satisfaction. Survivorship analysis was performed using Kaplan-Meier method and worst-case scenario analysis was performed whereby all patients were considered as revision when they declined study participation. Revision rates were compared in younger and older patients (age cut-off 60 years) and in patients with different body mass index (body mass index cut-off 35 kg/m. 2. ). Two-sided chi-square tests were used to compare these groups. RESULTS. Data was collected for 797 patients (909 knees) with an average follow-up of 29.6 months (range: 22 – 52 months). At 2.5-years follow-up, eleven knees were reported as revised, which resulted in a survivorship of 98.8% (Figure 2). Thirty-five patients declined to participate in the study yielding a worst-case survivorship of 96.0%. Higher revision rates were seen in younger patients (2.60% versus 0.93%, p = 0.09) and in morbidly obese patients (3.36% versus 0.91%, p = 0.03). Of all patients without revision, 92% was either very satisfied or satisfied with their knee function (Figure 3). CONCLUSION. In this multicenter study, robotic-assisted UKA was found to have high survivorship and satisfaction rate at short-term follow-up. Prospective comparison studies with longer follow-up are necessary in order to compare survivorship and satisfaction rates of robotic-assisted UKA to conventional UKA and robotic-assisted UKA to total knee arthroplasty. For any figures or tables, please contact authors directly (see Info & Metrics tab above).